Dustcontrol TSR 47 Stationary Vacuum System Instructions


Add to my manuals
34 Pages

advertisement

Dustcontrol TSR 47 Stationary Vacuum System Instructions | Manualzz

TSR 47, 22 kW

Part No 9049

Bruksanvisning i original

Original instructions

Originalbetriebsanleitung

VARNING! Läs bruksanvisningen före användning av maskinen.

WARNING Read the instruction manual before using the machine.

ACHTUNG! Bitte lesen Sie die Betriebsanleitung vor

Inbetriebnahme der Maschine sorgfältig durch. .

Dustcontrol reserverar sig för tryckfel och produktförändringar.

Dustcontrol reserves the right to change specifi cations without notice and is under no obligation to alter previously delivered products. Dustcontrol is not responsible for errors or omissions in this catalogue.

Keine Gewähr für Druckfehler. Produktänderungen vorbehalten.

Tillverkare/Manufactured by/Hersteller:

Dustcontrol AB

Kumla Gårdsväg 14

SE-145 63 Norsborg

Tel: + 46 8 531 940 00

Fax: + 46 8 531 703 05 [email protected]

www.dustcontrol.com

Såld av/Sold by/Verkauft von:

TSR 47, 22 kW - 2 Part No 9049

Innehållsförteckning

Säkerhetsföreskrifter ____________ 4

Tekniska data _________________ 5

Funktionsbeskrivning ___________ 6

Mått och uppställning __________ 6

Installation __________________7-8

Provkörning __________________ 9

Tillbehör _____________________ 9

Underhåll ___________________ 10

Garanti______________________ 11

Felsökning ___________________ 12

Reservdelar ________________ 31-32

EG-försäkran _________________ 33

Dustcontrol Worldwide ________ 34

Contents

Safety Considerations __________ 13

Technical Data ________________ 14

System Description ____________ 15

Dimensions and Arrangements __ 15

Installation ________________ 16-17

Test Running _________________ 18

Accessories __________________ 18

Service ______________________ 19

Warranty ____________________ 20

Trouble Shooting _____________ 21

Spare Parts ________________ 31-32

EG-declaration _______________ 33

Dustcontrol Worldwide ________ 34

Inhaltsverzeichnis

Sicherheitsvorschriften _________ 22

Technische Daten _____________ 23

Funktionsbeschreibung ________ 24

Maße und Aufstellung _________ 24

Installation ________________25-26

Probelauf ____________________ 27

Wartung ____________________ 28

Zubehör ____________________ 29

Gewährleistung ______________ 29

Fehlersuche __________________ 30

Ersatzteile _________________ 31-32

EG-Konformitätserklärung ______ 33

Dustcontrol Worldwide ________ 34

TSR 47, 22 kW - 3 Part No 9049

Säkerhetsföreskrifter

Läs hela detta instruktionshäfte innan maskinen startas.

Utrustningen får monteras och skötas endast av behöriga personer som tagit del av denna skrift. Dustcontrol ansvarar ej för skador på utrustningen som uppkommit pga felaktig installation eller felaktigt handhavande av utrustningen.

5. Elektricitet

En separat, låsbar arbetsbrytare måste installeras och vara lätt åtkomlig från den plats där pumpen står.

Försök aldrig att på egen hand ändra elektriska kopplingar. Ett fel kan medföra livsfara. Den elektriska installationen får endast utföras av behörig elektriker.

Se också punkt 7 - Varning.

Varning! Vid användandet av elektriska maskiner ska nedanstående grundläggande säkerhetsföreskrifter följas för att minska risken för brand, elstöt eller personskada.

1. Viktigt!

Inga heta eller glödande partiklar får sugas med enheten. Maskinen ska ej användas för explosiva varor, instabila eller pyrofora ämnen eller damm med minsta antändningsenergi (MIE) < 1mJ.

– VARNING! Användaren ska vara tillräckligt instruerad om användandet av dessa maskiner.

– VARNING! Denna maskin är endast för torr användning.

– FÖRSIKTIGHET! Denna maskiner får endast användas inomhus.

– FÖRSIKTIGHET! Denna maskin ska endast magasineras inomhus.

Bryt och lås arbetsbrytaren före demontering av skyddsplåtar och kanaler.

7. Kontroll av skador

Kontrollera regelbundet att maskinen inte har skador eller förslitningar. Uppstår skador ska dessa åtgärdas av en auktoriserad serviceverkstad som är godkänd av Dustcontrol eller av Dustcontrol själva.

Om nätsladden är skadad måste den bytas av Dustcontrol eller auktoriserad serviceverkstad, som är godkänd av Dustcontrol.

8. Varning

Använd endast tillbehör och utbytesdelar som fi nns i

Dustcontrols katalog.

OBS! Vid användandet av felaktiga delar eller piratdelar (framförallt fi lter och plastsäckar) kan maskinen läcka hälso-farligt damm med personskador som följd.

2. Arbetsmiljön

Håll utrymmet vid centralenheten rent. Lagra eller hantera inte lättantändliga vätskor eller gaser i närheten.

3. Överbelastning

Vid larmindikation - återstarta inte maskinen förrän felet är konstaterat och åtgärdat.

Använd maskinen för avsett ändamål och följ föreskrifterna för det material som sugs.

Denna apparat är inte avsedd att användas av personer (inklusive barn) med nedsatt fysisk, sensorisk eller mental förmåga eller brist på erfarenhet och kunskap, såvida de inte övervakas eller får instruktioner angående användning av apparaten av en person som ansvarar för deras säkerhet. Barn bör övervakas så att de inte leker med apparaten.

4. Kroppsskador

Varning för starkt undertryck

Starta aldrig pumpen utan att kanalerna är anslutna.

Låt aldrig sugpunkten komma i kontakt med någon kroppsdel. Prova aldrig undertrycket med handfl atan eller andra kroppsdelar. Det starka undertrycket kan skada hudens blodkärl.

Denna maskin är avsedd för kommersiellt bruk, till exempel i hotell, skolor, sjukhus, fabriker, butiker, kontor och uthyrare.

Varning för het utblåsluft

Tänk på att utblåsningsluften kan vara

150 oC varm.

Part No 9049 TSR 47, 22 kW - 4

Tekniska data

Benämning TPR 35 TPR 40 TPR 43 TSR 43 TPR 47 TSR 47 TPR 50 TSR 50

Standardmotor kW 11 15 18,5 18,5 22 22 30 30

Vikt kg 400

Max dP kPa 22

Nominellt tryck kPa 20

Max Q

Ljudnivå

26

22

28

22

46

35

29

23

50

37

30

25

54

40 m 3 /h 1000 1200 1400 650 1500 700 1600 800

MÄRKEFFEKT

V Hz

220-240/

380-420 50

TPR 35 TPR 40 TPR 43 TSR 43 TPR 47 TSR 47 TPR 50 TSR 50

11 kW 15 kW 18.5 kW 18.5 kW 22 kW 22 kW 30 kW 30 kW

- 106802 107202 107252 107702 107752 109202 109252

380-420/

660 50 106600 106800 107200 107250 107700

500 50 - 106801 107201 107251 107701

575 60 - 106806 107756

220/440 60 - 106804 107204 107254 107704 107754 109204 109254

Art. nr.

TRYCKALSTRING OCH EFFEKTFÖRBRUKNING

40

30

20

1 0 kPa Pu

6 0

50

4

0

10

6

8

2

3 5 7

1

200 400 600 800 1000 1200 1400 1600

6 1

2

3

4

5

7

Q m 3 /h

2 0

8

30 kW P

1. TPR 35 11 kW

2. TPR 40 15 kW

3. TPR 43 18,5 kW

4. TSR 43 18,5 kW

5. TPR 47 22 kW

6. TSR 47 22 kW

7. TPR 50 30 kW

8. TSR 50 30 kW

Kapacitetskurvorna är mätta som den faktiskt tillgängliga kapaci -teten i ett sugsystem. Det innebär att utlopps förluster från ett normalt utlopp

(ljud dämpare och backventil/böj) har subtraherats från pumpens/fl äktens tryck alstring. Med diff usor på utlopp kan högre undertryck erhållas.

Angivna luftfl öden gäller luft av normalt tryck (101,3 kPa) och normal temperatur (20 o C).

Vakuumalstrarna kan användas även för blås och ger då ett högre tryck

än vid sug.

TSR 47, 22 kW - 5 Part No 9049

Funktionsbeskrivning

Sidokanalstyp

Dustcontrol TSR är turbopumpar av sidokanalstyp med två turbinhjul. Mellan inlopp och utlopp löper skovlar genom en passage med mycket små spel. Det är därför viktigt att det inte kommer in några partiklar i pumpen

- haveririsk! Turbopumpen komprimerar luft och det är därför helt naturligt att den blir het under drift.

Kylluft

Dustcontrols TSR turbopumpar är remdrivna i två seriekopplade steg. Kylluft släpps in genom ett kylluftintag mellan de två pumpstegen. Det andra steget kyler då indirekt det första.

Luft hämtas från pumpens botten. Luftens passage får inte hindras. Skyddsgaller mot löv, papper etc levereras med som standard.

Backventil

När fl era enheter parallell kopplas ska Dustcontrol TSR kompletteras med backventil på inloppet.

Remdrift

Pumpen är remdriven. Utväxling och motor-storlek bestämmer pumpens kapacitet.

Om man behöver ändra kapaciteten är det möjligt att byta motor, remskivor och kilremmar. Om detta blir aktuellt - kontakta Dustcontrol för mer information. Se adresser och telefonnummer längst bak i denna instruktion.

Termoprotektor

Turbopumpen är utrustad med en termoprotektor. Om friliggande lagret blir varmare än 120 O C löser termoprotektorn ut. Termoprotektorn måste vara kopplad till elskåpet.

Mått och uppställning

TSR 43, TSR 47, TSR 50

TSR 47, 22 kW - 6 Part No 9049

Installation

A. Tillåtna belastningar vid montage.

B. Lyft ej från denna sida.

C. Pumpen ska monteras på betongfundament. Den är även förberedd för montering ovanpå en annan pump.

TSR 47, 22 kW - 7 Part No 9049

1. Skruva fast pumpen i betongplattan.

2. Ta loss skyddsplåtarna.

3. Anslut inlopp och utlopp. Starta aldrig pumpen utan att kanalerna är anslutna.

4. Inloppet ska alltid vara anslutet till en stoftavskiljare med fi lter - se fi gur B.

Inga partiklar får komma in i pumpen.

5.

Utloppet kan utrustas med ljuddämpare. Utloppsljudet sänks då från ca 75 dB(A) till ca 62-64 dB(A). Se

Tillbehör på sidan 12.

6.

Om utloppet riktas uppåt ska det avslutas med en böj så att inte regnvatten kommer in i utloppet, se fi gur C. Tänk på att blås- luften kan vara 100-150 O C varm.

7.

Den elektriska installationen ska göras av behörig elektriker. En separat, låsbar arbetsbrytare ska monteras i närheten av pumpen.

8.

Pumpens termoprotektor måste kopplas in för att garantin ska gälla.

9 . Styrskåpet ska utrustas med termiskt motorskydd som ställs och testas av elektriker. Kontrollera att pumpen har rätt

rotationsriktning.

TSR 47, 22 kW - 8 Part No 9049

Provkörning

1. Se till att arbetsbrytaren är frånslagen och låst. Kontrollera remspänningen (se fi gur B på nästa sida). Låt remskivorna rotera och lyssna så att inga skrapande ljud hörs. Kontrollera att inlopp och utlopp är ordentligt anslutna.

4. Slå till arbetsbrytaren. Starta pumpen och lyssna. En hög ton från turbinhjulen hörs. När pumpen hämtar luft från kylluftintaget hörs även ett svagt väsande.

5.

Mät trycket på sugsidan. Jämför med det tryck som anläggningen är dimensionerad för.

2. Montera skyddsplåtarna. Kontrollera så att det är möjligt att starta pumpen utan att någon som befi nner sig i närheten kan skadas och att alla uttag i systemet är stängda.

6.

Kontrollera sugsystemets funktion.

7.

Det är helt normalt att pumpens utlopp blir mycket varmt efter någon timmes

körning.

3. Anslut en manometer till sugsidan så nära pumpen som möjligt. Manometern ska vara kalibrerad till minst 60 kPa.

Tillbehör

Ljuddämpare

Art nr Ansl Dimensioner

A

Art nr A

Art nr 8051 Backventil ø160

Monteras på inloppssidan när fl era TSR parallellkopplas. För lämpliga rördetaljer - se

Dustcontrols katalog.

TSR 47, 22 kW - 9 Part No 9049

Underhåll

Pumpen ska ses över minst två gånger per år och smörjas enligt smörjintervallerna längst ned på denna sida.

1. Starta pumpen och lyssna efter missljud.

När alla uttag är stängda ska det höras ett svagt väsande från kylluftintaget.

2. Stäng av pumpen och lås arbetsbrytaren.

3. Ta bort skyddsplåtarna.

4. Dra runt remskivorna. Lyssna efter missljud.

5.

Kontrollera slitaget på remmarna och byt vid behov. Antingen byter man alla remmar eller ingen. Se fi gur A.

8. Se över anslutningar och kablar så att de är intakta.

9.

Sätt tillbaka skyddsplåtarna, slå på strömmen och provkör pumpen.

Byte av remmar

- Lyft motorn med mutter (1) och lossa remmarna.

- Byt remmar.

- Spänn remmarna med mutter (2). Justera spänningen. Se fi gur

B.

6.

Kontrollera att remskivorna inte är skeva och att axlarna är parallella. Remskivorna ska ligga i linje med varandra. Pumpens vinkel kan justeras med skruv (3), fi gur C.

7.

Turbopumpens lager ska smörjas med

Dustcontrol lagerfett för turbopumpar, art nr

9928.

Smörjning

- Pressa in fett i främre lagrets smörjnippel (4).

Se fi gur C.

- Lossa bakre lagrets kylfl äns (5). Kontrollera fettets kondition och fyll på nytt fett till 2/3 av lockets volym.

- Kontrollera O-ringen (Art nr 4789) och sätt tillbaka kylfl änsen.

Smörjintervall

22 kPa

25 kPa

28 kPa

30 kPa

40 kPa

-

-

-

1500 h

1000 h

Part No 9049 TSR 47, 22 kW - 10

Garanti

Garantitiden är ett år vid enskiftsarbete eller motsvarande tid vid fl erskift. Garantin avser fabrikationsfel och gäller under förutsättning att maskinen används på normalt sätt och får det underhåll som krävs. Dustcontrol tar inte ansvar för maskiner utustade med annat än originaldelar.

Termoprotektorn måste vara inkopplad.

Reparationer ska utföras av Dustcontrol eller av personal som godkänts av Dustcontrol. I annat fall förverkas garantin.

TSR 47, 22 kW - 11 Part No 9049

Felsökning

Problem

Motorn går inte.

Orsak

Elen avstängd.

Termoprotektorn utlöst.

Motorskyddet i elskåpet utlöst - motorn

överbelastad.

Elen når inte fram.

Åtgärd

Slå på elen.

Om termoprotektor på pump brutit ska felet undersökas och

åtgärdas på pumpen. Därefter kan larmet återställas med RESET.

Om motorskydd löst ut ska felet undersökas och åtgärdas. Därefter kan motorskyddet återställas.

Låt en elektriker se över kopplingar och ledningar.

Undersök varför den stängts av och om pumpen är redo att startas. Slå sedan på arbetsbrytaren.

Arbetsbrytaren avslagen.

Byt till rätt säkring.

Låt elektriker justera.

Motorn stannar direkt efter start.

Felaktig säkring.

Termisk säkring för lågt ställd.

Anslut eller rensa.

Motorn går men anläggningen suger inte.

Rör och slangar ej anslutna eller stopp i dessa.

Det fi ns ingen uppsamlingsanordning ansluten till stoftavskiljaren.

Pumpen roterar åt fel håll.

Kilremmarna har gått av.

Anslut en uppsamlingsanordning (säck eller annan behållare).

Låt en elektriker åtgärda.

Byt kilremmarna.

Kontrollera.

Motorn går men anläggningen suger dåligt.

Hål på slangar eller otätt rörsystem.

Igensatt fi lter i stoft-avskiljaren.

Onormalt ljud från pumpen.

Partiklar kan ha kommit in i pumpen.

Rensa eller byt.

Stäng av och beställ service.

Part No 9049 TSR 47, 22 kW - 12

Safety Considerations

Read all instructions before attemting to operate this machine.

Warning - Very hot exhaust air

Exhaust air can be very hot, up to 150O C.

by qualifi ed personnel who have study this user instruction.

Dustcontrol does not take responsibility for defective installation or maintenance.

5. Electricity

A separate lockable disconnect must be installed where it is readily accessible to the pump. Do not repair the electric components yourself, get somebo-

Warning! When using electric machines, basic safety precautions should always be followed to reduce the risk of fi re, electric shock and personal injury, including the following: connections may only be performed by a certifi ed electrician. See also under section 7, ’Warning’.

1. Important!

No hot particles nor ignition sources are allowed to be ”off ” position before demounting the safety panels or ducting.

for explosives, unstable or pyrophoric particles or dust of minimum ignition energy (MIE) <1mJ.

– WARNING Operators shall be adequately instructed on the use of these machines.

7. Checking for damage

Check the machine regularly for damage. If there are any damaged parts these should be repaired by a

Dustcontrol authorized service centre.

only.

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a hazard.

2. Work area environment

Keep the area around the central unit clean. Do not store or work with fl ammable liquids or gases near the machine.

3. Overload

If there is an alarm signal it should be carefully checked out to see that the machine is un damaged. If there are any damaged parts these should be repaired by a Dustcontrol authorized service centre. Always follow the regulations pertinent to the material you are working with. Do not use the machine for purposes that it is not intended for.

8. Warning

Use only accessories and replaceable parts which are available in the Dustcontrol catalogue. When using non-genuine parts, especially fi lters and plastic sacks, dust leaks could occur which may be hazardous to health.

Th

(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

Warning - High negative pressure

Do not start the pump without having it connected to the duct work. Never let the suction come in contact with parts of the body, for example a hand.

Th only, for example in hotels, schools, hospitals, injury may result.

TSR 47, 22 kW - 13 Part No 9049

Technical Data

Description TPR 35 TPR 40 TPR 43 TSR 43 TPR 47 TSR 47 TPR 50 TSR 50

Pump RPM

Weight rpm 3500 4000 4300 4300 4700 4700 5000 5000

Max dP kPa 22 26 28 46 29 50 30 54

Nom. Pressure kPa 20 22 22 35 23 37 25 40

Max Q

Sound Level of m 3 /h 1000 1200 1400 650 1500 700 1600 800

Inlet/Outlet Ømm 160/160 160/160 160/160 108/108 160/160 108/108 160/160 108/108

POWER RATING

V Hz

220-240/

380-420 50

TPR 35 TPR 40 TPR 43 TSR 43 TPR 47 TSR 47 TPR 50 TSR 50

11 kW 15 kW 18.5 kW 18.5 kW 22 kW 22 kW 30 kW 30 kW

- 106802 107202 107252 107702 107752 109202 109252

380-420/

660 50 106600 106800 107200 107250 107700

500 50 - 106801 107201 107251 107701

575 60 - 106806 107756

220/440 60 - 106804 107204 107254 107704 107754 109204 109254

Part No.

CAPACITY AND POWER CONSUMPTION

40

30

20

1 0 kPa Pu

6 0

50

4

0

10

6

8

2

3 5 7

1

200 400 600 800 1000 1200 1400 1600

6 1

2

3

4

5

7

Q m 3 /h

2 0

8

30 kW P

1. TPR 35 11 kW

2. TPR 40 15 kW

3. TPR 43 18,5 kW

4. TSR 43 18,5 kW

5. TPR 47 22 kW

6. TSR 47 22 kW

7. TPR 50 30 kW

8. TSR 50 30 kW and are stated empirically. Outlet pressure losses from a normal outlet (silencer, back-fl ow valve/bend) have been accounted for in the curve. Additional equipment such as a diff user can result in increased pressure loss and must be taken into consideration.

Stated air-fl ows are for standard air (101.3 kPa@ 20 o C). devices can also be used for positive pressure application and will generate a greater pressure diff erential.

TSR 47, 22 kW - 14 Part No 9049

System Description

Regenerative blowers

Dustcontrol’s turbopumps are regenerative blowers. TSR

Back fl ow valve

A back fl ow valve must be optionally installed on the inlet side of the unit when several units are to be installed in parallel.

impellers rotate in the blower housing through extremely airfl ow. TSR compresses air and it is therefore natural that it becomes hot while running.

Belt drive mine the capacity of the pump.

Cooling air

Turbopumps with TSR designation are series connected two stage belt driven units. Cooling air is introduced into the pump through a slot between the two stages. In this way the second stage cools the fi rst stage indirectly.

If changes are to be made to performance characteristic of the pump, this can be done by changing the motor and drive ratio. Contact Dustcontrol and you will recieve more information. Please see addresses and phone numbers on the last page of this document.

air must be ensured. As standard screen skirts are delivered with the pump as an protecting against leaves, papers etc.

For protection on the pump bearings the pump has thermal protection which will shut down the pump at the control pane

l.

Dimensions and Arrangements

TSR 43, TSR 47, TSR 50

TSR 47, 22 kW - 15 Part No 9049

Installation

A. Allowed pressures during installation.

B. Do not lift from this side.

C. The pump should be installed on a concrete pad. A second pump may be mounted on the top of the fi rst pump.

TSR 47, 22 kW - 16 Part No 9049

1. Ancor the pump to the concrete pad.

2. Remove the pump covers.

3. Connect the ducting to both the inlet and the outlet.

Do not start the pump without having it connected to the ductwork.

contaminated airfl ow .

5.

Extra silencing can be installed if the outlet sound level is to be lowered from approximately 75 dB(A) to approximately 62-64 dB(A). See Accessories on page 22.

6.

If the outlet is vertical, and exposed to the elements, rain protection should be installed (C).

Exhaust air can be very hot, up to 150 O C.

7.

Electrical connections may only be performed by a

certifi ed electrician. A separate lockable disconnect should be installed where it is readily accessible and within view of the pump.

8.

Th validate the warranty.

9.

Th load protection that should be adjusted and tested by a certifi ed electrician. Check for correct motor

rotation.

TSR 47, 22 kW - 17 Part No 9049

Test Running

1. Verify that the power is locked out. Inspect the belt tension (Figure B next page), rotate the pump and listen for any sound indicating worn bearings or misaligned impellers. Check that the inlet and outlet are properly connected.

4. Power up the pump and listen carefully for the following sounds; A high pitch whine is normal sound from the impeller blades. As pump draws cooling air through the slot between the two stages a weak hissing should be heard.

2. Mount the covering panels. Check that no persons can be hurt if the pump starts and that all outlets are closed.

5.

Measure the pressure. Compare with the dimension point.

6.

Check the function and tightness of the connected exhaust system.

3. Connect a manometer for negative pressure calibrated to min. 60 kPa to the suction side as close to the pump as possible.

7.

It is normal that the pump becomes hot

Accessories

Silencer

Part No Conn. Dimensions

A

Art nr A

Part No. 8051 Back Flow Valve 160 mm

Installed on the inlet side of the TSR when two or more units are parallel installed. For complimentary tubing details, see Dustcontrol catalogue.

TSR 47, 22 kW - 18 Part No 9049

Service

ted according to the lubrication intervals at the bottom of this page.

8. Inspect all cables and connections, repair if neccessary.

1. Start the pump and listen for abnormal sounds. When all outlets are closed a weak hissing sound should be heard from the slot between the two stages.

9.

Remount the protective panels, power up the pump and give it a test run.

3. Remove the protective panels from the pump.

4. Rotate the pump manually and listen for any sounds indicating a worn bearing or misligned impellers.

5.

Check the condition and tension of the drive belts. Th drive belts are matched, therefore new and old belts should never be used together. Always change the whole set. (A).

Changing the belts

- Lift the motor mounting plate with nut (1).

- Change belts.

- Tighten the belts with nut (2) and adjust to the tension illustrated (B).

6.

Check that the axles, pump and motor are parallel and the pulleys are true. Th should not run on an angle into the pulleys.

Th screw (3), fi g C.

7.

Th with Dustcontrol bearing grease for turbopumps, Part No.

9928.

Lubrication

(4), fi g (C). Press grease in until it comes out along the axle.

bearing cover plate (5) and checking the condition of the grease.

Fill the cavity 2/3 full with new grease.

- Exchange the O-ring, Part No. 4789 and replace the bearing cover plate.

Lubrication Interval

22 kPa

25 kPa

28 kPa

30 kPa

40 kPa

-

-

-

1500 h

1000 h

TSR 47, 22 kW - 19 Part No 9049

Warranty

ranty covers manufacturing defects and is valid under the condition that the machine is used under normal conditions on the task for which it was designed and is machines equipped with other than original spare parts.

Warranty repairs must be performed by Dustcontrol or their authorized representatives.

Unauthorized repairs render this warranty null and void.

TSR 47, 22 kW - 20 Part No 9049

Trouble Shooting

Problem

Motor will not run.

The motor stops directly after starting.

Motor runs but no suction.

Fault

Electrical supply is not connected.

Thermal overload tripped.

The thermal overload incorrectly set.

Suction tubing not connected.

Plugged tubing or hoses.

There is no plastic sack or container attached to the fi ler unit.

Pump rotation backwards.

Solution

Connect.

The motor protection tripped.

Electrical power does not reach the machine.

Electrical disconnect locked out.

Incorrect fuse.

If the thermal overload protection of the turbo pump is tripped, the fault must be located and corrected before operating the system. There-after, the indicator can be reset.

If the motor overload protection trips, the fault must be located and corrected. Thereafter the motor overload protection can be reset.

A qualifi ed electrician should check supply.

Find the person responsible for the lock out and check to see if system is clear for operation.

Reverse the lock out.

Change to correct fuse rating and type.

Electrician should be called for investigate.

Connect the tubing.

Clean.

Connect a plastic sack or a container.

Electrician should take care of.

Pump runs but poor suction.

Abnormal sound from the pump.

Drive belt broken.

Leakage in the ductwork.

Plugged fi lters.

Foreign matter in the pump.

Change.

Locate and repair.

Check the fi lters and clean or change if necessary.

Turn off the pump and order service.

TSR 47, 22 kW - 21 Part No 9049

Sicherheitsvorschriften

Lesen und beachten Sie diese Hinweise, bevor Sie die

Maschine benutzen.

Achtung - Hitze in der Ausblasluft!

Die Ausblasluft kann eine Hitze von

150 O C erreichen.

Die Ausrüstung darf nur von berechtigten Fachleuten montiert und gewartet werden, die auch diese Montage- und Serviceanleitungen durchgelesen haben. Dustcontrol

übernimmt keine Verantwortung von Schäden die durch unfachgemäßiger Installation oder durch fehlerhafte

Handhabung entstanden sind.

5. Elektrizität

In der Nähe der Pumpe muss ein verschließbarer

Hauptschalter installiert werden. Versuchen Sie nie selbst Eingriff e an elekt rischen Teilen vorzunehmen.

Ein Fehler kann lebens gefährlich sein. Die elektrische

Installation darf nur von berechtigten Fachleuten durchgeführt werden. Siehe Punkt 7 Achtung.

Achtung! Beim Gebrauch von elektrischen Maschinen sind zum Schutz gegen elekt rischen Schlag, Verletzungs- und Brand gefahr folgende grundsätzliche Sicher heits maß nahmen zu be achten.

1. Wichtig!

Es dürfen keine heißen oder glühenden Teilchen eingesaugt werden. Die Maschine sollte nicht für explosive, instabile und selbstentzündliche Partikel oder Stäube mit einer Mindestzündenergie (MZE) <1mJ verwendet werden.

– WARNUNG! Die Maschine darf nur von Personen eingesetzt werden, die sorgfältig in die Handhabung eingewiesen sind.

– WARNUNG! Nutzen Sie diese Maschine nur zum

Aufsaugen trockener Stäube.

– ACHTUNG! Diese Maschine darf nur im Innenbereich eingesetzt werden.

– ACHTUNG! Die Maschine muss im Innenbereich gelagert werden.

Demontieren Sie nie die Verschalungsbleche oder

Kanäle ohne vorher den Haupt-schalter der Pumpe abzuschalten und diesen zu verriegeln.

7. Kontrolle von Beschädigungen

Kontrollieren Sie regelmässig die Maschine auf Schäden oder Verschleiß. Bei Schäden darf die Maschine nur von Dustcontrol oder autorisierten Werkstätten repariert werden.

Wenn das Netzkabel beschädigt ist, muss es vom

Hersteller, dessen Kundendienst oder einer ähnlich qualifi zierten Person ersetzt werden, um Gefährdungen zu vermeiden.

2. Sicherheitszone

Die Umgebung in der Nähe der Saugeinheit muß sauber gehalten werden. Die Lagerung oder Handhabung von brennbaren Flüssigkeiten oder Gasen ist untersagt.

8. Achtung

Nutzen Sie nur Zubehör und Austauschteile die im

Dustcontrol Katalog erhältlich sind. Beim Einsatz von fehlerhaften Teilen oder Piratteilen (vor allem

Filter und Plastiksäcke) kann aus der Maschine gesundheits gefähr dender Staub austreten, der Gesundheitsschäden verursachen kann.

3. Überlastung der Maschine

Bei Alarmindikation darf die Maschine nicht gestartet werden bevor der Fehler behoben ist. Verwenden

Sie die Maschine nur für Arbeiten für die sie be stimmt ist. Befolgen Sie die Vor schrif ten zur Handhabung des abgesaug ten Materials.

4. Verletzungsgefahr

Achtung - Hoher Unterdruck!

Starten Sie die Pumpe nur mit angeschlossener

Rohrleitung. Vermeiden Sie Körperkontakt mit

Saug düsen. Prüfen Sie nie den Unterdruck mit der

Hand-fl äche oder anderen Körperteilen. Die Pumpe generiert hohen Unterdruck.

Die kräftige Saugwirkung kann die Blutgefäße der

Haut verletzen.

Diese Maschine darf nicht von Kindern betrieben werden. Personen mit reduzierten physischen, sensorischen oder mentalen Fähigkeiten dürfen die

Maschine nur betreiben, wenn Sie eine Einweisung und Beaufsichtigung durch eine Person erhalten, die für deren Sicherheit zuständig ist. Kinder müssen beaufsichtigt werden um sicherzustellen, dass diese nicht mit der Maschine spielen.

Die Maschine ist für den gewerblichen Gebrauch geeignet, wie z.B. in Hotels, Schulen, Krankenhäusern, Fabriken, Läden, Büros und Vermietungsgeschäften.

Part No 9049 TSR 47, 22 kW - 22

Technische Daten

Benennung TPR 35 TPR 40 TPR 43 TSR 43 TPR 47 TSR 47 TPR 50 TSR 50

Gewicht kg

Max dP kPa 22 26 28 46 29 50 30 54

Nennunterdruck kPa 20 22 22 35 23 37 25 40

Max Q m 3 /h 1000 1200 1400 650 1500 700 1600 800

Schallpegel

Gehäuse 66 66 66 66 66 66 66 66

Einla

β/Auslaβ Ømm 160/160 160/160 160/160 108/108 160/160 108/108 160/160 108/108

NENNLEISTUNG

V Hz TPR 35 TPR 40 TPR 43 TSR 43 TPR 47 TSR 47 TPR 50 TSR 50

11 kW 15 kW 18.5 kW 18.5 kW 22 kW 22 kW 30 kW 30 kW

220-240/

380-420 50 - 106802 107202 107252 107702 107752 109202 109252

380-420/

660 50 106600 106800 107200 107250 107700

500 50 - 106801 107201 107251 107701

575 60 - 106806 107756

220/440 60 - 106804 107204 107254 107704 107754 109204 109254

Art. Nr.

DRUCKERZEUGUNG UND LEISTUNG kPa Pu

6 0

50

40

30

4

20

1 0

0

10

6

8

2

3 5 7

1

200 400 600 800 1000 1200 1400 1600

4

6 1

2

3

5

7

Q m 3 /h

2 0

8

30 kW P

1. TPR 35 11 kW

2. TPR 40 15 kW

3. TPR 43 18,5 kW

4. TSR 43 18,5 kW

5. TPR 47 22 kW

6. TSR 47 22 kW

7. TPR 50 30 kW

8. TSR 50 30 kW

Die Kapazitätskurven sind die tatsächlich zugängliche Leistung in einem Saugsystem. Dies bedeutet eine Subtraktion der Ausla ß verluste eines normalen Auslasses (Schalldämpfer und Rückschlagventil/Bogen) vom erzeugten Druck der Pumpe bzw. des Ventilators.

Mit einem Diff usor am Ausla ß kann höherer Unterdruck erzeugt werden.

Die angegebenen Luftromstwerte gelten für Luft bei normalem

Druck (101,3 kPa) und normaler Temperatur (20°C).

Die Vakuumerzeuger können auch für Überdruckerzeugung eingesetzt werden und bringen hierbei einen grö ß eren Druck als der Saugdruck.

TSR 47, 22 kW - 23 Part No 9049

Funktionsbeschreibung

Seitenkanalverdichter

Die Dustcontrol Turbopumpe TSR ist ein Seitenkanalverdichter und besteht aus 2 Turbinenräder. Die Rotoren laufen zwischen Auslass und Einlass durch eine Passage mit sehr kleinem Spielraum. Deshalb ist es sehr wichtig, dass die Pumpe keine Partikeln ansaugt - Beschädigungsgefahr! Die Turbo-pumpe komprimiert die Luft und es ist ganz normal, dass das Pumpengehäuse beim Betrieb heiss wird.

Kühlluft

Die Turbopumpe TSR hat einen Riemen- antrieb für die zwei in Reihe geschalten Pumpstufen. Kühlluft wird durch einen Spalt zwischen den beiden Pumpenstufen ein-gelassen. Die zweite Pumpe kühlt dadurch indirekt die erste.

Rückschlagventil

Die TSR muß mit einem Rückschlagventil komplettiert werden, wenn mehrere Einheiten parallel geschaltet sind.

Riemenbetrieb

Die Pumpe ist mit Riemen angetrieben. Die Kapazität hängt von der Motorleistung und dem Übersetzungsverhältnis ab.

Um die Kapazität zu ändern, kann man den Motor, die

Riemenscheiben und die Keil-remen auswechseln. Sollte eine solche Veränderung erwünscht werden, nehmen Sie

Kontakt mit der Dustcontrol-Vertretung auf (letzte Seite

- Adressen).

Der Ventilator des Elektromotores holen Luft vom Boden des Gehäuses. Die freie Passage der Luft darf nicht gehindert werden. Ein Schutznetz z.B. gegen Laub, Papier wird mitgeliefert.

Bei Temperatur über 120 O ermoprotektor.

Dieser Protektor muss zum Schaltschrank angeschlossen werden.

Maße und Aufstellung

TSR 43, TSR 47, TSR 50

TSR 47, 22 kW - 24 Part No 9049

Installation

A. Zugelassene Belastungen bei Montage.

B. Anheben nicht in dieser Richtung.

C. Die Pumpe soll auf Betonfundament montiert werden. Sie ist auch zur Aufstellung auf einer zweite Pumpe vorbereitet.

TSR 47, 22 kW - 25 Part No 9049

1. Schrauben Sie die Pumpe in das Pumpenfundament an.

2. Die Schutzbleche losmachen.

3. Einlass und Auslass anschliessen. Starten Sie nie die

Pumpe ohne Verrohrung.

4. Der Einlass soll immer an einen Staubabscheider mit

Filter angeschlossen sein (B), so daß die Pumpe keine

Partikeln ansaugen kann.

5.

Der Auslass kann mit Schalldämpfer ausgerüstet werden. Der Geräuschpegel des Auslasses wird dann von ca

75 dB(A) auf ca 62-64 dB(A) abgesenkt. Siehe Seite 32

Zubehör.

6.

Bei Abluftöff nung nach oben muss das Rohr mit einem Regenschutz versehen werden (Rohrbogen o. ähnl). (Fig. C). Die Ausblasluft kann eine Hitze von

7.

Die elektrische Installation darf nur von berechtigten Fachleuten gemacht werden. Ein absperrbarer Betriebsschalter soll immer in der

Nähe der Pumpe installiert werden.

8.

Der Th sein, andernfalls wird die Garantie ungültig.

9.

Der Schaltschrank muss mit thermischem

Motorschutz ausgerüstet sein, der von berechtigen

Fachleuten installiert und geprüft ist. Überprüfen

Sie, dass die Pumpe die richtige Rotationsrichtung

hat.

TSR 47, 22 kW - 26 Part No 9049

Probelauf

1. Hauptschalter abschalten und verriegeln. Kontrollieren Sie die Riemenspannung, siehe Figur B, nächste

Seite. Durch Rotieren der Riemenscheiben kontrollieren Sie, dass keine kratzende Geräusche entstehen. Kontrollieren Sie, dass der Einlass und Auslass ordnungsgemäß angeschlossen sind.

2. Montieren Sie die Schutzbleche. Überprüfen, dass die Pumpe problemlos gestartet werden kann ohne

Personen in der Nähe der Pumpe und alle Auslässe des Systems geschlossen sind.

3. Ein auf mindestens 60 kPa abgestimmtes Mannometer auf der Ansaugseite so nahe der Pumpe wie möglich anschliessen.

4. Hauptschalter einschalten. Pumpe starten und auf ungewöhnliche Geräusche achten. Von den Rotorenrädern muss ein hoher Ton zu hören sein. Wenn die

Pumpe Luft vom Spalt zwischen den beiden Pumpenstufen ansaugt, ist auch ein schwaches Zischgeräusch zu hören.

5.

Druck auf der Ansaugseite messen und mit dem

Druck vergleichen, für den die Anlage dimensioniert ist.

6.

Funktion des Saugsystems kontrollieren.

7.

Es ist völlig normal, dass der Auslass der

Pumpe nach einer Stunde Betrieb sehr

TSR 47, 22 kW - 27 Part No 9049

Wartung

Die Pumpe soll mindestens zweimal im Jahr kontrolliert werden und geschmiert s. Schmierinterwalle nachstehende Tabelle.

8. Überprüfen dass Anschlüsse und Kabel intakt sind.

1. Pumpe starten und auf ungewöhnliche Geräusche achten.

Wenn alle Sauganschlüsse des Systems geschlossen sind, sollte ein leichtes Zischgeräusch vom Vakuumventil zu hören sein.

9. Befestigen Sie die Schutzbleche, schalten Sie den

Strom ein und machen Sie einen Versuchslauf

2. Pumpe abschalten und Betriebsschalter verriegeln.

3. Nehmen Sie die Schutzbleche ab.

4. Drehen Sie die Riemenscheiben und hören Sie nach kratzenden Geräuschen.

5. Kontrollieren Sie die Riemen in Hinsicht auf Abnutzung,

Austauschen wenn es nötig sein sollte. Alle Riemen müssen gleichzeitig getauscht werden (A).

Austauschen der Riemen

- Heben Sie den Motor mit der Mutter (1) und entfernen Sie die

Riemen.

- Tauschen Sie die Riemen aus.

- Ziehen Sie die Riemen mit der Mutter (2) an. Stellen Sie die

Spannung ein (Fig. B).

6. Kontrollieren Sie, dass die Scheiben nicht schief sind und dass die Achsen parallell sind. Die

Riemen sollen gerade gegen die Scheiben einlaufen. Die Winkellage der Pumpe kann mit der Schraube (3) eingestellt werden (Fig. C).

7. Das Lager der Turbopumpe soll mit Dustcontrol Lager- fett für Turbopumpen, art nr 9928, geschmiert werden.

Schmiering

- Pressen Sie Fett in den Schmiernippel des Vorderlagers ein (4).

Siehe Fig. C.

- Kühlfl ansch (5) losschrauben. Zustand des Fettes kontrollieren und ggf. neues Fett bis auf 2/3 des Deckelvolumens einfüllen.

- O-Ring, Art. Nr 4789 austauschen und Kühlfl ansch wieder befestigen.

Schmierintervalle

22 kPa

25 kPa

28 kPa

30 kPa

40 kPa

-

-

-

1500 h

1000 h

Part No 9049 TSR 47, 22 kW - 28

Zubehör

Schalldämpfer

Art Nr. Anschl. Maße

A

Art Nr. A

Art Nr. 8051

Rückschlagventil ø160

Wird an der Einlaßseite angebracht, wenn mehrere TSR parallel geschaltet werden. Übrige Rohrteile s. Dustcontrol Katalog.

Gewährleistung

Die Gewährleitungszeit beträgt ein Jahr bei einschichtigem

Betrieb und verkürzt sich entsprechend bei mehrschichtigem Betrieb. Die Garantie gilt für Fabrikationsfehler und unter der Voraussetzung, dass die Maschine auf sachgemäße Weise eingesetzt und regelmäßig gewartet wird. Der

Einsatz von Piratteilen führt zu Verlust des Garantieanspruches.

Reparturen dürfen nur von Dustcontrol oder einer von

Dustcontrol anerkannten Fachfi rma durchgeführt werden, andernfalls erlischt die Garantie..

TSR 47, 22 kW - 29 Part No 9049

Fehlersuche

Problem

Der Motor läuft nicht.

Fehler

Kein Stromanschluss.

Thermoprotektor ausgeschaltet.

Motorschutz im

Schaltschrank hat ausgelöst.

Motor überlastet.

Keine Stromzufuhr.

Hauptschalter ausgeschaltet.

Maßnahme

Strom anschliessen.

Sofern der Thermoprotektor die

Pumpe ausschaltet ist, die Störung an der Pumpe zu untersuchen und zu beseitigen. Danach wir die

Warnfunktion mit ”RESET” aufgehoben.

Sofern der Motorschutz auslöst, ist die Störung zu untersuchen und zu beseitigen. Danach kann der Motorschutz zurückgestellt werden.

Von Elektriker Verbindungen und

Leitungen überprüfen.

Nachsehen wieso der Haupt-schalter abgestellt ist.

Hauptschalter einschalten.

Sicherung austauschen.

Von Elektriker ändern lassen.

Der Motor bleibt sofort nach dem Start stehen.

Falsche Sicherung.

Motorschutz zu niedrig eingestellt.

Der Motor läuft, aber die Maschine saugt nicht.

Die Rohrleitungen zwischen dem Staubabscheider und dem Vakuumerzeuger nicht angeschlossen.

Rohre oder Schläuche verstopft.

Kein Sammelbehälter am

Staubabscheider angebracht.

Die Pumpe läuft in der falschen Drehrichtung.

Die Keilremen sind abgerissen.

Der Motor läuft, aber die Maschine saugt schlecht.

Loch in Schläuchen oder undichtes Rohrsystem.

Filter verstopft.

Abnormale Geräuschentwicklung der Pumpe.

Es können Partikeln in die

Pumpe eingedrungen sein.

Rohrleitungen anschließen.

Kontrollieren und reinigen.

Plastiksack, Behälter usw. anbringen.

Von Elektriker ändern lassen.

Austauschen.

Überprüfen.

Reinigen oder austauschen.

Abschalten und Wartungsdienst anrufen.

TSR 47, 22 kW - 30 Part No 9049

Reservdelar / Spare Parts / Ersatzteile

4954

4789

*

4636

8199

4906

*

*

*

4905

4635

*

(TPR)

4756

4782

4635

4762

*

4636

*

4781

4763

(TSR)

4757

*

*

4760

4923

4926

4928

495201

495202

4920 4946

4936

4927

4947

* ingår i reparationssats art nr 4164

4943

4922

4925

4921

4932

4926

4710

8001

4700/4701

3031

3040

4942

4931

4786

Motor

4949

Art. nr Benämning

4164 Reparationssats TPR/TSR 40-50

4635 Turbinhjul

4636 Turbinhus och kåpa

4757 Gavel

4760 Täcklock

4763 Distansbricka

4782 Täckplåt, mellandel TPR

4905 Distansring

4906 Distansring

4954 Tätningslock

3007 Jetkoppling

3031 Jetkoppling

3040 Kona ø 110/108

471800 Kilremshjul 50 Hz

471801 Kilremshjul 60 Hz

492900

3007

4933

4934

476601

4937

4777

4935

4775

Art. nr Benämning

Svenska

Art. nr Benämning

4737 Remskiva TPR 35 11 kW

476601 Gummipackning

4775 Axel

4777 Stödskruv

478000 Remskiva TPR/TSR 40 15 kW

478001 Remskiva TPR/TSR 43 18,5 kW

478002 Remskiva TPR/TSR 47 22 kW

478003 Remskiva TPR/TSR 50 30 kW

4786 Vibratordämpare

4789 O-ring

4922 Tvärstycke

4923 Takplåt

4925 Främre täckplåt TPR

4926 Sidoplåt

4927 Bottenplåt

4931 Pumpstativ

4932 Stos

TSR 47, 22 kW - 31

4935 Ställskruv

4936 Luftkanal

4937 Motorhylla

4942 Ljuddämpare

4943 Lyftögla

494500 Kilrem 15 kW, 18,5 kW, 50 Hz

494501 Kilrem 30 kW, 50 Hz

15 kW, 18,5 kW, 60 Hz

494502 Kilrem 22 kW, 30 kW, 60 Hz

494503 Kilrem 11 kW, 50 Hz

494504 Kilrem 22 kW, 50 Hz

4946 Ventilationsgaller

4947 Ventilationsgaller

4949 Distansring 11-22 kW

495201 Kabelförskruvning 11-22 kW

495202 Kabelförskruvning 30 kW

8199 Termoprotektor komplett 120 o C

Part No 9049

471800

471801

494503

494502

494501

494500

494504

4737

478003

478002

478001

478000

English

* included in repair

kit part no. 4164

Part No Description

4164 Repair kit TPR/TSR 40-50

4635 Impeller

4756 Intermediate part TPR

4757 Cover

4760 Cover

Deutsch

* Teile des Reparatur-

satzes Art Nr 4164

Art. Nr. Benennung

4164 Reparatursatz TPR/TSR 40-50

4635 Gebläserad

4636 Gehäuse und Deckel

4781

4782

Intermediate part TSR

Intermediate part TPR

3007 Clamp

3040 Steel cone ø 110/108

4757 Stirnwand

4760 Verschlußdeckel

4762 Pumpenwelle

4763 Distanzscheibe

4782 Abdeckbleck,

4905 Distanzring

4906 Distanzring

4954 Dichtungsdeckel

3007 Verbinder

3031 Verbinder

3040 Konus ø 110/108

471800 Pump pulley 50 Hz

471801 Pump pulley 60 Hz

4737 Motor pulley TPR 35, 11 kW

476601 Gasket

TPR/TSR 40 15 kW

TPR/TSR 43 18,5 kW

TPR/TSR 47 22 kW

TPR/TSR 50 30 kW

4789 Gasket

4920 Frame side, left

4921 Frame side, right

4923 Top cover panel

4925 Front cover panel TPR

4926 Side cover panel

4928 Back cover panel

471800 Keilriemenrad 50 Hz

471801 Keilriemenrad 60 Hz

4737 Riemenscheibe TPR 35 11 kW

476601 Gummiabdichtung

4775 Achse

4777 Stellschraube

478000 Riemenscheibe

TPR/TSR 40 15 kW

478001 Riemenscheibe

TPR/TSR 43 18,5 kW

478002 Riemenscheibe

TPR/TSR 47 22 kW

478003 Riemenscheibe

TPR/TSR 50 30 kW

4786 Vibratordämpfer

4789 O-ring

4922 Querstück

4925 Abdeckblech, hinten TPR

4926 Seitenabdeckblech

4927 Grundblech

4933 Flanged bend, right

4934 Flanged bend, left

4931 Pumpenstativ

4932 Staßverbindung

4936 Cooling air housing

4942 Silencer

494500 Drive belt set

15 kW, 18.5 kW, 50 Hz

494501 Drive belt set 30 kW, 50 Hz

15 kW, 18.5 kW, 60 Hz

494502 Drive belt set

22 kW, 30 kW, 60 Hz

494503 Drive belt set 11 kW, 50 Hz

494504 Drive belt set 22 kW, 50 Hz

4949 Spacer ring 11-22 kW

4935 Stützschraube

4936 Luftkanal

4937 Motorgestell

4942 Schalldämpfer

4943 Hebeöse

494500 Keilriem 15 kW, 18,5 kW, 50 Hz

494501 Keilriem 30 kW, 50 Hz

15 kW, 18,5 kW, 60 Hz

494502 Keilriem 22 kW, 30 kW, 60 Hz

494503 Keilriem 11 kW, 50 Hz

494504 Keilriem 22 kW, 50 Hz

4946 Ventilationsgitter

4947 Ventilationsgitter

4949 Distanzring 11-22 kW

495201 Zugentlastung 11-22 kW

495202 Zugentlastung 30 kW

8199 Termoprotektor komplett 120 o C

TSR 47, 22 kW - 32 Part No 9049

EG-försäkran om överensstämmelse

Svenska

Vi försäkrar härmed att TSR 47 är i överensstämmelse med följande bestämmelser och standarder; 2006/42/EC,

2006/95/EC, 2004/108/EC, EN 60204-1.

Serienummer och tillverkningsår indikeras på märkplåt på maskinen.

EG-declaration of conformity

We declare that TSR 47 is in conformity with following directives and standards; 2006/42/EC, 2006/95/EC,

2004/108/EC, EN 60204-1.

English

Serial Number and manufacturing year are indicated in a rating plate on the machine.

Deutsch

EG-Konformitätserklärung

Wir deklarieren daß TSR 47 mit den folgenden aufgeführten Standards oder standardisierten Dokumenten, übereinstimmt; 2006/42/EC, 2006/95/EC, 2004/108/EC, EN 60204-1.

Serienummer und Herstellungsjahr werden auf einer Plakette an der Maschine eingeprägt.

TSR 47, 22 kW - 33 Part No 9049

Dustcontrol AB

Box 3088

Kumla Gårdsväg 14

SE-145 03 Norsborg

Tel: +46 8 531 940 00

Fax: +46 8 531 703 05 [email protected]

www.dustcontrol.com

AT

Dustcontrol Ges.m.b.H.

Gradnerstrasse 120-124

AT-8054 Graz

Tel: +43 316 428 081

Fax: +43 316 483 041 [email protected]

www.dustcontrol.at

CA

Dustcontrol Canada Inc.

664 Welham Road

CA-Barrie, Ontario L4N 9A1

Tel: +1 877 844 8784

Fax: +1 705 733 1614 [email protected]

www.dustcontrol.ca

CH

Rosset Technik

Maschinen Werkzeuge AG

Ebersmoos

CH-6204 Sempach-Stadt

Tel: +41 41 462 50 70

Fax: +41 41-462 50 80 [email protected]

www.rosset-technik.ch

DE

Dustcontrol GmbH

Siedlerstraße 2

DE-71126 Gäufelden-

Nebringen

Tel: +49 70 32-97 56 0

Fax: +49 70 32-97 56 33 [email protected]

www.dustcontrol.de

DK

Erenfred Pedersen A/S

Rebslagervej 7

DK-9000 Aalborg

Tel +45 98 13 77 22

Fax. +45 98 16 56 11 [email protected]

www.ep.dk

Dansk Procesventilation ApS

Vangeleddet 73

DK-2670 Greve

Tel: +45 61 270 870 [email protected]

www.dansk-procesventilation.dk

ES

Barin, s.a.

C/ Cañamarejo, N o 1

Poligono Industrial

Rio de Janeiro

ES-28110 Algete - Madrid

Tel: +34 91 6281428

Fax: +34 91 6291996 [email protected]

www.barin.es

FI

Dustcontrol FIN OY

Valuraudankuja 6

FI-00700 Helsinki

Tel: +358 9-682 4330

Fax: +358 9-682 43343 [email protected] www.dustcontrol.fi

FR

Dustcontrol AB France

Box 3088

Kumla Gårdsväg 14

SE-145 03 Norsborg

Tel: +46 8 53194016

Fax: +46 8 531 703 05 [email protected]

www.dustcontrol.com

HU

Vandras Kft

Kossuth L. u. 65 III.29

HU-1211 Budapest

Tel: +36-1-427-0322

Mobile: +36-20-9310-349

Fax: +36-1-427-0323 [email protected]

www.vandras.hu

IT

Airum srl via Maestri del Lavoro 18

Roveri-2

IT - 40138 Bologna

Tel: +39 (0)516 025 072

Fax: +39 (0)515 347 78 [email protected]

www.airum.com

KR

E. S. H Engineering Co.

671-267 Sungsu1ga 1dong

Sungdonggu (P.O)133-112

KR-Seoul Korea

Tel: +82 (0)2 466 7966

Fax: +82 (0)2 466 7965 [email protected]

www.esheng.co.kr

MY

Blöndal Städa (M) Sdn. Bhd.

Blöndal Building, Jalan Penyair,

Section U1, Off jalan Glenmarie,

MY-40150 Shah Alam

Tel: +60 603 5569 1888

Fax: +60 603 5569 1838 [email protected]

www.blondal.net

BENELUX

All In Techniek Nunspeet B.V.

Industrieweg 62 D-E

NL-8071 CV Nunspeet

Tel: +31 341-25 07 26

Fax: +31 341-25 07 36 [email protected]

www.allintechniek.nl

DUSTCONTROL WORLDWIDE

NO

Teijo Norge A.S

Husebysletta 21

Postboks 561

NO-3412 Lierstranda

Tel: +47 3222 6565

Fax: +47 3222 6575 fi [email protected]

www.teijo.no

PL

Bart Sp. z. o.o.

ul. Będzińska 41/1

PL-41-205 Sosnowiec

Tel: +48 32 256 22 33

Fax: +48 32 256 22 35 [email protected]

www.bart-vent.pl

PT

Metec-Mecano Técnica, Lda.

Campo Pequeno, 38

PT-1000-080 Lisboa

Tel: +351 21 7970291

Fax: +351 21 7963485 [email protected]

www.metec.pt

RU

SovPlym Ltd

Revolution Highway, 102-2

RU-195279, St Petersburg

Tel: +7-812-33-500-33

Fax: +7-812-227-26-10 [email protected]

www.sovplym.com

SG

Blondal (S) Pte Ltd

Stada Division

Block 60 Ubi Crescent,

01-02 Ubi Techpark

SG-Singapore 408569

Tel: +65 6741 7277

Fax: +65 6745 2204 [email protected]

www.blondalstada.com

UK

Dustcontrol UK Ltd.

Old Barn, Home Farm

Business Park

Church Way, Whittlebury,

Northants NN12 8XS

England - GB

Tel: +44 1327 858001

Fax: +44 1327 858002 [email protected]

www.dustcontrol.co.uk

US

Dustcontrol Inc.

6720 Amsterdam Way

US-Wilmington NC 28405

Tel: +1 910-395-1808

Fax: +1 910-395-2110 [email protected]

www.dustcontrolusa.com

www.dustcontrol.com

Part No 9049 TSR 47, 22 kW - 34

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement