DATA SHEET UniBus 8 Zone Expander The UniBus 8 Zone Expander connects to an Integriti Security Controller (ISC) or an 8 Zone LAN Expander via the UniBus Port. It provides an additional 8 Zone Inputs that support all Integriti Zone Types including Multistate and Counter types along with extra detector power supply connections (DET+) to simplify device wiring. The UniBus 8 Zone Expander is designed for installation within the same tamper-protected enclosure as its UniBus host module. The UniBus device is connected directly to the host module or another UniBus device via the UniBus patch cable supplied. Host Module Compatibility The UniBus 8 Zone Expander is compatible with the following UniBus Host Modules: • Integriti ISC Controller (Part. 996001 series) - Connect up to 2 • Integriti 8 Zone RS-485 LAN Expander (Part. 996005PCB&K) - Connect up to 3 UniBus Host Module UniBus Device UniBus Device Compatibility Guide ILAM 8 Zone Expander 2 0 3 0 8 Relay Expander 4 4 4 2 2 Door / 2 Reader Expander 0 3 0 3 16 Floor Lift Interface 6 6 6 6 RS-232/RS-485 UART 4 4 0 0 Analogue Expander 4 0 6 0 2nd Network Interface Card 1 1 0 0 Connectivity es on 8Z us iB Un iB E us x p 8 a Z n o d n e e r 8 Universal Zone Inputs Support for Multistate EOL circuits Support for counter type inputs Programmable de-bounce times DIP switch addressable first zone 1, 9, 17 or 25 UniBus loop-through connectors 4 Way DET+ 13.75V outputs 2 LED status/fault indicators Surge protected inputs Over-The-Wire firmware upgradable Integriti “C” size footprint 94 x 94mm Can be installed above other “C” size PCB’s** A Snap off strip is included to allow installation above Integriti “B” size PCB’s** ** 35mm standoff kit required - Part Number 999009 8 Zone Expander n • • • • • • • • • • • • • IAC U Features ISC C VD 5 3.7 x4 1 s lo U u niB h ug hro -t op Un iBu s In In DATA SHEET UniBus 8 Zone Expander UniBus Installation Specifications s u niB U t 6 to ine Up -cab us s in niB ice U ev D PCB Size Code: Integriti “C” size PCB Size: 94(L) x 94(W) (mm) PCB size including snap off strip: 105(L) x 94(W) (mm) Height: 15(D)(mm) (28mm with UniBus cable connected) Installation Environment: 0ºC - 70ºC @15% - 90% Relative humidity (non-condensing) Electrical Power Supply Input: 11V to 14V DC via host module Static Current Consumption: 75mA. (not including detector power) DET+: Output Voltage 13.75V DC - sourced from host DET+ Output Current: Limited to available current from host Connections UniBus Devices are designed for installation within the same enclosure as the UniBus host module. A UniBus host can interface a maximum of six UniBus devices in any combination, provided they are all within the intended functionality of the host module Zone Inputs: 8 DET+ Out: 4 UniBus Port: 1 UniBus Loop-through Port: 1 Connection to Host Module: Via 270mm UniBus patch lead (supplied) Power Considerations The UniBus host module supplies DET+ current and static device current to all connected UniBus devices. Total current consumption is, therefore the sum of all: - Static Current of all connected UniBus devices - Static Current of host module - Host module battery charging current - Ancillary devices connected to all DET+ connections - Ancillary devices connected to host module’s RS-485 LAN+ Compliance Electrical Environmental Ordering Options 996500PCB&K Integriti UniBus 8 Zone Input Expander PCB & Accessories (Includes 270mm UniBus patch cable) Spare UniBus patch cables 996791SS - UniBus Patch Cable 150mm 996791S - UniBus Patch Cable 220mm 996791L - UniBus Patch Cable 270mm 996791LL - UniBus Patch Cable 475mm 996791XL - UniBus Patch Cable 675mm Hardware U n iB H M o u s o t s d u le Physical
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement