50193 | 50196 | HW Series | SunSun HW-303 | SunSun HW-404B | 50194 | Manual | WilTec Bedienungsanleitung


Add to my manuals
34 Pages

advertisement

50193 | 50196 | HW Series | SunSun HW-303 | SunSun HW-404B | 50194 | Manual | WilTec Bedienungsanleitung | Manualzz

Bedienungsanleitung

DE/EN/FR

Externer Aquariumfilter

MODELL HW-302 / HW-303 / HW-304 / HW-402B / HW-403B / HW-404B

ARTIKEL 50197 / 50195 / 50193 / 50196 / 50194 / 50192

Vor Inbetriebnahme Bedienungsanleitung und Sicherheitshinweise lesen und beachten

Read and follow the operating instructions and safety information before using for the first time.

Avant la mise en service, lisez le mode d’emploi et les consignes de sécurité et respectez-les.

Technische Änderungen vorbehalten!

Durch stetige Weiterentwicklungen können Abbildungen, Funktionsschritte und technische Daten ge ringfügig abweichen.

Aktualisierung der Dokumentation

Haben Sie Vorschläge zur Verbesserung oder haben Sie Unregelmäßigkeiten festgestellt, nehmen

Sie bitte Kontakt mit uns auf.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 1

WICHTIGE HINWEISE:

220-240V AC, 50Hz, 15W/20W/50W IP44

Bitte lesen Sie vor der Montage und Betrieb

Zum Schutz vor Verletzungen sollten grundlegende Sicherheitsvorkehrungen beim Umgang mit dem

Gerät eingehalten werden:

1. Das Gerät ist nur für den aquaristischen Gebrauch und nur für den Innenbereich.

2. Zur Vermeidung von Stromschlägen ist besondere Vorsicht geboten, da Wasser in diesem Gerät verwendet wird. Versuchen Sie nicht, es in keinem Fall selbst zu reparieren. Geben Sie das

Gerät an die autorisierte Servicestelle für die Wartung oder entsorgen Sie es.

3. Achten Sie darauf, dass die Ausgangsspannung der auf dem Typenschild der Pumpen angege benen entspricht.

4. Wenn das Gerät ins Wasser eingetaucht ist, NICHT danach greifen! Bitte trennen Sie das Gerät zuerst vom Netz und berühren es erst dann.

5. Überprüfen Sie das Gerät nach der Installation. Es sollte nicht eingesteckt werden, wenn seine elektrischen Komponenten nass sind.

6. Betreiben Sie kein Gerät mit einem beschädigten Kabel oder Stecker oder in defektem Zustand.

Das Netzkabel des Geräts kann nicht ersetzt werden. Wenn das Kabel beschädigt ist, sollte man das Gerät verschrotten.

7. Stellen Sie sicher, dass das Netzkabel unterhalb der Steckdose Schlaufen zu einer "Tropf schleife" bildet. Dies wird verhindern, dass Wasser entlang des Kabels in die Steckdose läuft.

8. Sorgfältige Aufsicht ist notwendig, wenn das Gerät von oder in der Nähe von Kindern verwendet wird.

9. Bei Nichtgebrauch, vor dem Einfügen oder Entnehmen von Teilen und vor der Reinigung bitte

Netzstecker ziehen.

10. Nicht installieren oder lagern Sie das Gerät nicht so, dass es Feuchtigkeit oder Temperaturen unter dem Gefrierpunkt ausgesetzt ist.

11. Achten Sie darauf, das Gerät sicher installiert ist, bevor Sie es starten.

12. Lesen und beachten Sie alle Anweisungen, die mit dem Gerät und auf dem Gerät geliefert wer den.

13. Die Pumpe darf nicht trocken laufen.

14. Nie Zubehörteile verwenden, die nicht vom Hersteller empfohlen verwenden. Es kann zu Feuer,

Stromschlag und / oder zu Verletzungen führen.

15. Verwenden Sie das Gerät für den Hausgebrauch und in der in dieser Anleitung angegebenen

Weise und in trockener Umgebung.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 2

1. Um Ihren Filter einzurichten, öffnen

Sie die Verschlüsse (1+2) des Hauptcontainers vom Filterkopf. Dadurch werden Kopf und Basis des Filters getrennt.

2. Sie erreichen nun die Filterkörbe, um die Filtermedien zu reinigen oder aufzufüllen. Durch umgekehrtes

Durchführen des Schrittes 1. wird der

Filterkopf wieder auf dem Container befestigt.

Modellabhängig

3. Drücken Sie die Zu- und Ablaufhähne in den Filterkopf und befestigen sie durch Betätigen des kleinen

Hebels zwischen den beiden Hähnen. Dieser Hebel ist gleichzeitig das

Verschlussventil der Schläuche. Dann befestigen Sie Ihre Schläuche an den

Hähnen und befestigen sie mit den

Schraubkappen.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 3

4.Befestigen Sie dann die Eingangsröhren und die Verteilerleiste entsprechend dem Diagramm

5. Dann den blauen Primer-Knopf auf dem Filterkopf drücken. Dadurch saugt der Filter Wasser durch den

Schlauch. Gegebenenfalls wiederholen, bis das Leitungssystem mit Wasser gefüllt ist.

6. Der Schalter (3), der Ihre CUV-Lampe und die UV-Anzeige schaltet, befindet sich an der Seite des Filterkopfes. Bitte überprüfen Sie Ihre CUV regelmäßig, um sicher zu sein, dass sie funktioniert.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 4

7. Sobald der Filterkopf vom Container getrennt wird, schaltet der

Schutzschalter das CUV aus Sicherheits gründen ab.

Anleitung zum Wechsel der CUV-Lampe (Röhre)

(Betrifft nur die Modelle mit UVC-Einheit.)

1. Um Ihren Filter einzurichten, öffnen

Sie die Verschlüsse (1+2) des Hauptcontainers vom Filterkopf. Dadurch werden Kopf und Basis des Filters getrennt.

2. Sie erreichen nun die Filterkörbe, um die Filtermedien zu reinigen oder aufzufüllen. Durch umgekehrtes

Durchführen des Schrittes 1. wird der

Filterkopf wieder auf dem Container befestigt.

2. Die alte UV-Röhre herausziehen.

3. Entnahme der alten und Einstecken der neuen CUV-Röhre.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 5

Zusammenbau der Wasserentnahme- und -rückführleitungen.

Artikel Model UVC Durchfluss Förderhöhe Gewicht Kabel

50197 HW-302 -

50195 HW-303 -

1000 L/h

1400 L/h

50193 HW-304 2000 L/h

50196 HW-402B 9W 1000 L/h

50194 HW-403B 9W 1400 L/h

50192 HW-404B 9W 2000 L/h

1.4 m

2.0 m

2.5 m

1.4 m

2.0 m

2.5 m

3.5 kg

5.0 kg

5.5 kg

3.5 kg

5.0 kg

6.0 kg

1.8 m

1.8 m

1.8 m

1.8 m

1.8 m

1.8 m

Abmessungen

232x232x395 mm

550x350x430 mm

610x390x470 mm

660x500x415 mm

550x350x450 mm

610x390x480 mm

Körbe

4

3

3

3

3

4

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 6

Filterbetrieb und Problemlösungen

Problem

Beim Drücken des blauen Primer-

Knopfes ohne Erfolg

Der Motor läuft nicht

Blockierter Wasserfluss

Grund

Falsche Verbindung von ein- und

Ausgang

Keine Spannung

Die Welle ist gebrochen

Das Laufrad ist gelöst oder der

Motor ist durch Schmutz blockiert

Schlauchanschlusseinheit ist extrem verschmutzt

Schläuche sind falsch verbunden

Lösung

Ein- und Auslaufanschluss wechseln, die Schmutzwasserseite ist die Eingangsseite

Strom einschalten

Welle auswechseln

Das Laufrad befestigen und

Schmutz entfernen

Schlauchanschlusseinheit ausbauen und innen mit Bürste reinigen

Überprüfen, ob die Schläuche verwickelt oder geknickt sind

Bei Filterstart ungewöhnliche Geräusche

Beim Betrieb ungewöhnliche Geräusche

Übermäßige Schmutzablagerungen in den Schläuchen

Regelmäßig die Innenoberflächen der Verbindungsschläuche und rohre reinigen

Filtermaterial ist dicht

Fremdluftzutritt über Schauchverbindungen

Luftreste im Filterbehälter

Verschmutzte, verdrehte oder verschobene O-Ringe

Luftreste im Filter

Filtermaterial herausnehmen und mit

Aquarienwasser auswaschen

Überprüfen, ob die Schauchverbindungen dicht sind (siehe auch S.8)

Spannungsversorgung an lassen.

Den Filter leicht schütteln, um verbliebene Luft zu entfernen

Alle O-Ringe auf korrekten Sitzt prüfen und ggf. gründlich Reinigen

Beschädigte Pumpenteile

Den fi lter container mehrfach leicht schütteln, um Restluft zu enfernen

Beschädigtes Teil ersetzen

Übermäßige Wasserverunreinigung und Propellerverschmutzung

Verunreinigungen beseitigen

* weitere Hinweise zu Pflege, Reinigung, Wartung und Problemlösungen siehe S.8.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 7

Filterbetrieb und Problemlösungen

Geräuchreduzierung / Fremdluft

Insbesondere die Ansaugung und die damit verbundene Oberflächenabsaugung muss auf Dichtigkeit geprüft, und an den Wasserstand des Aquariums angepasst werden. Sollte dies aus Aquarium-Technischen Gründen nicht möglich sein, verschließen Sie die Öberflächenabsaugung bitte vollständig damit keine Fremdluft in den Filter gelangen kann.

Entlüften des Filtersystems

Nehmen Sie den Rücklaufschlauch der das Wasser vom Filter in das Becken leitet und führen diesen in einen sauberen Eimer der unterhalb des Filters steht.

Belassen Sie den Schlauch in diesem Eimer und führen dann den Entlüftungsvorgang aus indem Sie die den manuelle Pumpe betätigen. Achten sie darauf das der maximal mögliche Durchfluss an der Ein-Auslass Kupplung eingestellt ist. Sobald keine Luftblasen mehr zu sehen sind, verschließen Sie den Schlauch mit einem Finger und montieren Sie diesen wieder wie vorgesehen an der Rückführungsverrohrung am oben Rand des Aquariums.

Undichtigkeit nach der Installation oder Reinigung

Bei einer geringen Undichtigkeit nach der Installation oder Reinigung des Filters liegt wahrscheinlich ein Problem mit der Abdichtung zwischen Schlauchanschlussadapter und dem Filterkopf vor.

Der Einsteckadapter, an dem die Schläuche angeschlossen werden, besitzt auf der unteren Seite zwei O-Ringe die in dem Filterkopf abdichten müssen.

Wenn diese verschmutzt, verrutscht oder beschädigt sind dichten diese nicht mehr gegen den Filterkopf ab und es gelangt Wasser von dieser Stelle in den

Filterkopf des Aquariumfilters.

Die Austrittstelle ist dann die tiefste Stelle des Filterkopfs und dies sind typischer

Weise die seitlichen Klemmstellen, die den Filterkopf mit dem

Filterbehälter verbindet.

Dieser Fehler ist schnell und ohne großen Aufwand zu beheben.

Sie müssen lediglich die O-Ringe reinigen und kontrollieren. Wichtig ist auch

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 8

das der Teil wo die Ringe im Filterkopf selber eingesteckt werden komplett sauber ist. An dieser Stelle können sich Algen bilden oder sich Sand sammeln, die das Abdichten der O-Ringe beinträchtigen oder verhindern können, wenn keine regelmäßige Reinigung vorgenommen wird.

Dieses Problem kann auch bei eine Neuinstallation z.B. durch Sand auftreten.

Bitte lassen Sie sich bei der Reinigung ausreichend Zeit, wenn man hierbei nicht sorgfältig vor geht, dann kann es leider dazu kommen das der Filter auch nach einer Reinigung Undichtigkeiten aufweist.

Sollte trotz einer Gründlichen Reinigung immernoch Wasser an der genannten

Stelle austreten muss der Sitzt der O-Ringe im inneren des Adapters überprüft werden. Dies erfordert es den Ein-Auslass Adapter zu öffnen. Kontaktieren Sie unseren Support.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 9

1 Zu- und Ablaufstutzen 7 Filterablaufbogen

2 Filter kopf 8 Verbindungsrohr

3 Container

4 CUV-Röhre

5 Filterabdeckung

6 Filterkörbe

13 Filtereinlaufbogen

14 Schmutzeinlauf-T

9 Einleitungsrohr 15 Ablaufrohr

10

Einleitungsrohrabschluss

16 Ablaufkorb

11 Schmutzwassereinlauf

12 Verbindungsrohr

17

Saugnäpfe z. Befestigen

18 Schläuche

Filtermaterial

Keramikringe Aktivkohle

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Filterwatte Bio Balls

Seite 10

Grundlagen - Filtermedien

Das im Lieferumfang enthalten Filtermaterial ist eine Grundausstattung.

Bitte informieren Sie sich, welche Filtermaterialien für Ihr Aquarium geeignet sind, da sich das je nach Fisch- und Pflanzenbesatz unterscheiden kann.

Bitte verwenden Sie nur in einer Stufe des Filters eine Filterwatte. Diese sollte regelmäßig erneuert werden, da das verschmutze Vlies sehr schnell zu einer

Verringerung der Filterleistung führen kann.

Außenfilter bestehen aus mehreren Schichten. Das angesogene Wasser wird also in mehrere Stufen gefiltert.

Die unterste Schicht besteht aus Bio Balls. Sie bieten nützlichen Bakterien Raum zur Ansiedlung und halten Grobschmutz fest. Abgedeckt werden die Bio Balls durch eine Lage Filtermatte. Darüber kommt eine Schicht mit kleinen Filterröhrchen aus Keramik. Auch diese, liefert nützlichen Bakterien Raum zur Ansiedlung.

Diese Schicht wird durch Filtervlies abgedeckt.

Zusätzlich kann hier auch noch eine Lage Aktivkohle (in einem Netz oder teils auch als Filtermatte erhältlich) die letzte Schicht bilden. Diese sollte aber nicht dauerhaft, sondern nur nach Medikamentenbehandlung und bei schwebstoffbedingen Wassertrübungen, eingesetzt werden.

Bei der Neuanschaffung eines Aquarium Filters oder nach einer kompletten Reinigung müssen die nützlichen Bakterien zunächst wieder angereichert werden.

Dafür gibt es spezielle Bakterienkulturen, die in den Aquarium Filter gegeben werden können und so den Start erleichtern.

Grundsätzlich gilt, von unten nach oben:

1.Stufe: mechanische / teilbiologische Filterung

2.Stufe: biologische Filterung

3.Stufe: chemische Filterung (Aktivkohle, Torf, Phosphat Ex etc.)

Bei 4 Stufen Filtern kann je nach Bedarf um eine mechanische oder biologische

Filterstufe erweitert werden.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 11

EG-Konformitätserklärung

(gemäß den Richtlinien 2004/108/EC)

Hersteller / verantwortliche Person

WilTec Wildanger Technik GmbH Koenigsbenden 12

52249 Eschweiler, Deutschland erklärt, dass das Produkt: Externer Aquariumfilter

Type:

Verwendungszweck:

HW-Serie

Reinigen von Aquariumwasser bei bestimmungsgemäßer Verwendung den grundlegenden Anforderungen und den weiteren entsprechenden Vorgaben gemäß den Richtlinien

2004/108/EC aufgrund seiner Konzipierung und Bauart sowie der von uns in Verkehr gebrachten Ausführung entspricht.

Bei der Bewertung des Produkts hinsichtlich der Anforderung der Richtlinien kamen die folgenden Standards zur Anwendung:

EN 55014-1:2006A1+A2

EN 55014-2:1997+A1

EN61000-3-2:2000+A2

EN61000-3-3:1995+A1+A2

Bei einer Änderung des Produktes verliert diese Erklärung Ihre Gültigkeit.

Eschweiler, 13. Oktober 2009

Bernd Wildanger

Geschäftsführer

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 12

Manual

DE/EN/FR

Aquarium External Filter

MODELL HW-302 / HW-303 / HW-304 / HW-402B / HW-403B / HW-404B

PRODUCT 50197 / 50195 / 50193 / 50196 / 50194 / 50192

Vor Inbetriebnahme Bedienungsanleitung und Sicherheitshinweise lesen und beachten

Read and follow the operating instructions and safety information before using for the first time.

Avant la mise en service, lisez le mode d’emploi et les consignes de sécurité et respectez-les.

Technische Änderungen vorbehalten!

Durch stetige Weiterentwicklungen können Abbildungen, Funktionsschritte und technische Daten ge ringfügig abweichen.

Aktualisierung der Dokumentation

Haben Sie Vorschläge zur Verbesserung oder haben Sie Unregelmäßigkeiten festgestellt, nehmen

Sie bitte Kontakt mit uns auf.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 1

IMPORTANT SAFEGUARDS:

220-240V AC, 50Hz, 15W/20W/50W IP44

Please read thoroughly before installation and operation

To guard against injury, basic safety precautions should be followed when handling the appliance, as the following included:

1. The appliance is only for aquarium and indoor use.

2. To avoid possible electric shock, special care should be taken since water is employed in the use of this appliance. Do not attempt to repair it by yourself. Return the appliance to the authorized service facility for maintenance or discard it.

3. Make sure that your outlet voltage corresponds to the stated voltage on the rating label of the pumps.

4. If the appliance is submerged into the water, DON’T reach for it! Please cut the power supply

FIRST and then fetch it.

5. Carefully examine the appliance after installation. It should not be plugged in if its electrical com ponents are wet.

6. Do not operate any appliance with a damaged cord or plug, or in abnormal state. The supply cord of the appliance cannot be replaced. If the cord is damaged the appliance should be scrapped.

7. Make sure that the electrical cord loops form a “Drip Loop” below the electrical outlet. The use of a drip loop will help prevent any water leaks or splashes from running down the electrical cord into your outlet. Instead of any water getting into your outlet it will simply drip off the cord at the lowest point in the loop.

8. Close supervision is necessary when the appliance is used by or near children.

9. Always unplug the appliance when not in use, before putting on or taking off parts, and before cleaning.

10. Do not install or store the appliance where it is exposed to moisture or to temperatures below freezing.

11. Make sure the appliance is securely installed before operating it.

12. Read and observe all the instructions supplied with the appliance and on the appliance.

13. The pump must not be run dry.

14. Never use accessories which are not recommended by the appliance manufacturer. It may result in fire, electric shock and/or personal injury.

15. Use the appliance ONLY for domestic purposes and in the way indicated in these instructions and place it in a dry environment.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 2

1. To set your filter up, the buckles (1) and (2) should be unclipped from the main body of the filter head this will then seperate the head from the base of the filter.

2. You can then access your filter trays to be able to clean the filter media or add filter media. Repeat step one to refasten the filter head to the base of the filter.

Depending on the model

3. Push the inlet and outlet taps into the filter head and fasten using the small handle in between the taps this is also the shut of valve. After this attach your hose to each tap and secure using the screw caps.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 3

4. According to the diagramm then attach the input downpipes and output spraybars.

5. According to the diagramm then press down the blue primerbutton on top of the filter head this will prime the filter drawing water in through the hose. Repeat this if necessary until all pipework is full with water.

6. The switch to (3) turn your UV and indicator on and off is located in the side of the filter head. Please check the UV regulary when cleaning your filter to make sure it is in full working order.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 4

7. At any condition, when the barrel is seperated by the cover, the protect switch will be off. Then the UV will be extinguish to avoid the damage to body.

The Method of replacing the UV light tube

This applies only to UV-Unit models

1. According to the diagrammatic presentation (1), please open the lid from the mail body carefully. Put the lid in inversion, then hold the quarzhose tube and circumgyrate it lightly, just as the picture shows.

When the gap of the quartzhose tube and the gap of the connection of the light tubes are accordant, pull out the quartzhose tube.

2. According to the diagrammatic representation, pulling out the bad light tube.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 5

Installing the new light tube and the quartzhose tube.

Articel Model UVC Output Delivery height Weight Cabel

50197 HW-302 1000 L/h 1.4 m 3.5 kg 1.8 m

Dimension

232x232x395 mm

50195 HW-303 -

50193 HW-304 -

1400 L/h

2000 L/h

2.0 m

2.5 m

5.0 kg

5.5 kg

1.8 m

1.8 m

550x350x430 mm

610x390x470 mm

50196 HW-402B 9W 1000 L/h

50194 HW-403B 9W 1400 L/h

50192 HW-404B 9W 2000 L/h

1.4 m

2.0 m

2.5 m

3.5 kg

5.0 kg

6.0 kg

1.8 m

1.8 m

1.8 m

660x500x415 mm

550x350x450 mm

610x390x480 mm

Trays

3

3

4

3

3

4

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 6

Filter management

Problem

Pressing the inhale buckle (blue buckle), the filter has no response

The motor is not Operation

Cause Solution

The wrong joun of input and output bar

The power is off

Join input and output bar again, the bar with dirtiness entrance is input bar

Turn on the power

The shaft is broken Replace the shaft

The impeller is missing or the motor is clogged with foreign materials such as pebbles and shells

Set the impeller or clean out the drive system

Inhibited water flow

(Inhibited functioning)

Hose adaptor unit is exessively dirty Detach the hose adaptor unit and clean the inside with a brush

Hoses have been incorrectly connected

Excessive dirt build-up in the hoses Periodically clean the inside of the hoses and the intake and drainage pipes

Filter media is clogged

Check whether the hose entangled or crimped

Remove the filter material and wash with tank water

Abnormal sound Emitted when starting the filter

Air is entering from the hose connection.

Air is remaining in the filter case.

Please check if the hose connections are sealed (see also P.8)

Leaving the power on, shake the unit to help remove remaining air.

Abnormal sound Emitted when

Operating the filter

Dirty, displaced or distorted O-

Rings

Air is remaining in the filter.

Control all O-Rings, they have to be inserted in their place and fitted correctly; if necessary clean thoroughly

Remove and replace the plug ire the socket 3-4 times Gently shake the filter to remove remaining air.

Damaged impeller/drive magnet or spindle.

Replace parts (consult place of purchase)

Decrease ihre water flow die to water staining or dirt ors the impeller/drive magnet

Set the impeller or clean out the drive system

*Further notes on care, cleaning, maintenance and solutions to possible problems see P.8.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 7

Filter operation and problem solving

Noise reduction/ external air

Especially the suction intake /inlet and the connected suction surface must be checked for tightness and adjusted according to the water level of the aquarium.

In case this is not possible due to aquarium technical reasons, seal the whole suction surface so that no external air can get into the filter.

De-aerating/ evacuating air

Take the return-flow hose that conducts the water from the filter to the tank and lead it into a clean bucket that is placed below the filter. Lead the hose into the bucket and carry out the dearation process (evacuate the air) by activating the manual pump. Please make sure that the possible maximal flow is adjusted to the inlet-outlet connector. As soon as no air bubbles can be seen, seal the hose with a finger und and install it again as intended on the return pipe at the top edge of the aquarium.

Leakage after installation or cleaning

In case of a slight leakage still persists after the installation or the cleaning of the filter, this indicates that the problem is most likely the sealing between the hose connector adaptor and the filter head (cover lid)

The plug-in adaptor, to which the hoses are connected, has on the lower side two O-rings that must seal the connection inside the filter lid. If these O-Rings are dirty, displaced (out of place) or damaged they cannot seal properly anymore and water escapes in the filter lid/cover of the aquarium filter.

The leak point is then the lowest point of the filter cover/lid and appears typically at the lateral clamping points that connect the cover lid with the filter tank/canister.

The remedy is here as simple as the failure itself. You have to rinse and check the O-rings. Make sure that the spots where the O-rings have to be inserted and positioned are free of dirt. On these particular spots algae formation can appear and impair or damage the O-rings’ sealing if no regularly cleaning is carried out.

This problem can also appear in case of a new installing because of sand, for instance.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 8

Please allocate sufficient time for rinsing and cleaning; if this is not done carefully and thoroughly, it can happen that the aquarium canister filter still leaks after the

O-ring sealings have been cleaned.

If, despite a thorough cleaning the water leakage at the above-mentioned spots still persists, you must check the O-ring seating inside the adaptor. This requires opening the inlet/outlet adapter. Please contact our customer service.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 9

1 inlet and outlet connection

2 Barrelhead

3 Main body

4 Light tube

5 Draining Skep Cover

6 Draining Skep

Filtermaterial

7 Output curvy bar

8 Connected bar

9 Spray bar

10 Spray bar cover

11 Dirtiness entrance

12 Connected bar

13 Input curvy bar

14

Joint of dirtiness entrance

15 Input bar

16 Input cover

17 Sucking disc for fix

18 pipe

Ceramic Ring Active Carbon Biochemical Cotton

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Bio-Ball

Seite 10

Basics– Filter media

The delivered filter media represents only the basic filter material needed for your aquarium.

Please inform yourself what filter materials are suitable for your aquarium because these can differ depending on the fish and plants living in your aquarium.

Please use for only one stage of the filter one filter wadding (one piece). This should be regularly renewed because dirty fleece/wadding can quickly lead to a decrease in filter efficiency.

Aquarium external filters consist of several layers. The water (that is sucked) is filtered in several stages.

The lowest layer (stage) consists of bio balls. These balls offer bacteria a large settling area and retain coarse dirt. The bio balls should be covered by a layer with filter fleece/wadding. Above it a layer with ceramic rings should follow. These also create optimal conditions for bacteria settling.

Additionally you can place here another layer of activated carbon (in a netting bag or partly also as filter mat available) and this will form the last filter layer.

This should not be permanent employed, but it should be used after a medication treatment and for turbid water with suspended particles.

When you purchase a new aquarium filter or after it has been fully cleaned the useful bacteria must be enriched again. For this reason there are special bacteria cultures that can be supplied in the aquarium to facilitate their settlement.

It basically applies from bottom to top:

1. Stage: mechanical/ partial biological filtering

2. Stage: biological filtering

3. Stage: chemical filtering (activated carbon, peat, phosphate etc.)

If necessary the aquarium filter can be extended to 4 stages by adding a mechanical or biological filter stage.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 11

Notice

DE/EN/FR

Filtre extérieur d'aquarium

Modèle HW-302 / HW-303 / HW-304 / HW-402B / HW-403B / HW-404B

PRODUIT 50197 / 50195 / 50193 / 50196 / 50194 / 50192

Vor Inbetriebnahme Bedienungsanleitung und Sicherheitshinweise lesen und beachten

Read and follow the operating instructions and safety information before using for the first time.

Avant la mise en service, lisez le mode d’emploi et les consignes de sécurité et respectez-les.

Technische Änderungen vorbehalten!

Durch stetige Weiterentwicklungen können Abbildungen, Funktionsschritte und technische Daten ge ringfügig abweichen.

Aktualisierung der Dokumentation

Haben Sie Vorschläge zur Verbesserung oder haben Sie Unregelmäßigkeiten festgestellt, nehmen

Sie bitte Kontakt mit uns auf.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 1

AVIS IMPORTANT:

220-240V AC, 50Hz, 15W/20W/50W IP44

Veuillez lire attentivement la notice avant l'installation et la mise en service.

Afin d'éviter le risque de blessures, les mesures de sécurité de base devront être respectées dans le maniement de l'appareil.

1. L'appareil est seulement concu pour l'utilisation dans le domaine de l'aquariophilie et seulement pour le domaine intérieur.

2. Afin d'éviter des blessures dûes à des décharges électriques, nous vous demandons de faire particulièrement attention, puisque l'eau est utilisée pour le fonctionnement de l'appareil. N'essayez jamais de réparer l'appareil par vous-mêmes. Donnez l'appareil à un service qualifié pour l'entretien ou la réparation ou débarassez-vous en.

3. Veillez à ce que la tension de sortie corresponde à celle mentionnée sur la plaque d'identification des pompes.

4. Si l'appareil venait à être immergé, n'y touchez pas! Coupez d'abord le courant avant d'y toucher.

5. Après installation, contrôlez l'appareil. Il ne doit pas être branché si ces parties électriques sont mouillées.

6. Ne mettez pas l'appareil en marche si le câble électrique était endommagé ou dans un état dé fectueux. Le câble secteur de l'appareil ne peut pas être remplacé, en cas d'endommagement, l'appareil complet doit être mis aux ordures.

7. Veillez à ce que le câble secteur forme une boucle pour les gouttes d'eau au-dessous de la prise afin d'éviter que l'eau ne puisse s'introduire dans la prise de courant après avoir coulé le long du câble.

8. Vous devez porter à cet appareil une attention particulière si l'appareil est utilisé à proximité d'enfants.

9. Veuillez toujours débrancher l'appareil avant de rajouter ou de retirer des pièces ou si vous ne vous en servez pas.

10. N'installez pas l'appareil dans un endroit humide ou où la température descend au-desssous de 0°C.

11. Veillez à ce que l'appareil soit installé de facon sûre et stable avant de le mettre en marche.

12. Lisez attentivement toutes les informations ou indications livrées avec l'appareil ou étant inscrites sur lui.

13. La pompe ne doit pas fonctionner à sec.

14. Ne jamais utiliser de pièces détachées qui ne sont pas recommandées par le fournisseur. Cela peut mener à des incendies, électrocutions ou autres blessures.

15. Utilisez l'appareil dans votre domicile, tel que décrite dans la notice et dans un endroit sec.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 2

Afin d'installer votre filtre, ouvrez les fermetures du bac principal (1+2) de la tête du filtre. En faisant cela, la tête et la base du filtre seront séparées.

2. Vous atteindrez alors vos paniers filtre, pour nettoyer les matériaux filtre ou les remplir. En procédant à l'opération inverse, vous refixerez la tête du filtre sur le bac.

dépendant du modèle

3. Introduisez, en appuyant, les tubes d'arrivée et d'écoulement dans la tête du filtre et fixez-les en vous servant du petit levier entre les deux tubes.

Ce levier est en même temps la valve de fermeture des tubes. Puis raccordez vos tuyaux aux tubes et fixez-les avec les capuchons à visser.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 3

4. Fixez alors les conduites d'entrée et les conduites de sortie selon le diagramme.

5. Puis appuyer le bouton bleu d'autoaspiration sur la tête du filtre. Le filtre aspire alors l'eau par le tuyau.

Recommencer l'opération jusqu'à temps que le système de conduites soit rempli d'eau.

6. Le bouton (3), qui met en marche la lampe CUV et l'indicateur

UV, se trouve sur le côté de la tête du filtre. Veuillez contrôler votre lampe UV régulièrement, pour être sûrs qu'elle fonctionne bien.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 4

7. Dès que la tête du filtre est séparée du bac, le disjoncteur interrupteur arrête la lampe pour des raisons de sécurité.

Notice pour l'échange de la lampe UV (tube)

Concerne seulement les modèles avec unité de raccordement UV

1. Enlever la tête du filtre (voir point 1 de la notice) et la poser sur l'envers.

Puis tourner avec précaution le tube quartz pour le séparer de la tête, dans le sens inverse des aiguilles d'une montre comme sur la photo.

2. Quand les marques placées sur le tube quartz et sur la douille se trouvent au même niveau, retirer le verre quartz avec précaution.

2. Enlevez l'ancien tube UV.

3. L'ancien tube est enlevé et le nouveau tube est mis en place

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 5

Montage des conduites pour la prise et l'écoulement de l'eau

Produit Modèle UVC Capacité

50197 HW-302 1000 L/h

50195 HW-303 -

50193 HW-304 -

1400 L/h

2000 L/h

50196 HW-402B 9W 1000 L/h

50194 HW-403B 9W 1400 L/h

50192 HW-404B 9W 2000 L/h

Hauter de refoulement max.

1.4 m

2.0 m

2.5 m

1.4 m

2.0 m

2.5 m

Poids câble Dimensions

3.5 kg 1.8 m 232x232x395 mm

5.0 kg 1.8 m 550x350x430 mm

5.5 kg 1.8 m 610x390x470 mm

3.5 kg 1.8 m 660x500x415 mm

5.0 kg 1.8 m 550x350x450 mm

6.0 kg 1.8 m 610x390x480 mm

Paniers

3

3

4

3

3

4

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 6

Solutions au problème de fonctionnement du filtre

Problème

On appuie le bouton d'autoaspiration en vain

Le moteur ne marche pas

Le flux de l'eau est bloqué

Raison

Mauvais raccordement de l'entrée et de la sortie

Solution

Echanger les raccords d'entrée et de sortie, le côté d'eau sale est le côté d'entrée.

Brancher l'appareil Pas de tension

L'arbre est cassé Echanger l'arbre

La roue de roulement n'est pas bien fixée et le moteur est bloqué par la saleté.

Le raccordement des tuyaux est extrêmement sale

Fixer la roue et enlever les saletés.

Démonter l'unité de raccordement des tuyaux et la nettoyer de l'intérieur avec une brosse

Les tuyaux sont mal raccordés Vérifier que les tuyaux ne soient pas pliés

Trop de dépôts de saletés dans les tuyaux

Nettoyer régulièrement les surfaces intérieures des tuyaux et des conduites de connection

Bruits bizarres lors de la mise en marche du filtre

Les matériaux filtres sont bouchés

Entrée d'air extérieur par les raccords de tuyaux

Enlever les matériaux filtre et les laver avec l'eau de l'aquarium.

Veuillez vérifier que tous les raccords de tuyaux sont bien étanches. (voir aussi page 8)

Bruits bizarres pendant le fonctionnement

Restes d'air dans le bac filtre

Joints toriques sales, tordus ou déplacés.

Laisser branché. Secouez légèrement le filtre pour faire évacuer l'air restant.

Vérifier le bon positionnement de tous les joints toriques et les nettoyer soigneusement si nécessaire.

Restes d'air dans le filtre Secouer plusieurs fois le filtre pour faire évacuer le reste d'air

Pièces de la pompe endommagées Remplacer la pièce endommagée

Trop de saletés dans l'eau ou hélice sale

Enlever les saletés

*Vous trouverez d’autres indications concernant le nettoyage, l’entretien et les solutions de problèmes à la page 8.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 7

Mise en service du filtre et solutions aux problèmes.

Réduction des bruits /Présence d’air dans le filtre

L’aspiration et tout particulièrement l’aspiration de surface qui y est jointe doit

être contrôlée quant à son étanchéité et adaptée au niveau d’eau de l‘aquarium.

Si cela ne devait pas être possible pour des raisons techniques de l‘aquarium, nous vous demandons de fermer complètement l’aspiration de surface pour que de l’air venant de l’extérieur ne puisse pas pénétrer dans le filtre.

Vidange d’air du système filtre

Enlevez le tuyau de sortie qui conduit l’eau du filtre vers le bassin d‘aquarium et mettez -le dans un seau propre que vous déposerez en dessous du filtre. Laissez le tuyau dans le seau et procédez à la vidange d’air en utilisant la pompe manuelle. Veillez à ce que le débit d’eau maximum soit réglé au raccord d’entrée et de sortie. Dès que vous voyez qu’il n‘y a plus de bulles qui sortent des deux tuyaux , bouchez le tuyau avec un doigt de facon à ce qu’il n y ait pas d‘air qui puisse s’y infiltrer, et remontez-le comme prévu à la conduite de retour sur le bord supérieur de l’aquarium.

Non étanchéité après installation ou entretien

Si une légère fuite survient après l’installation ou après un entretien du filtre il y a certainement un problème d’étanchéité entre l’adaptateur du raccord de tuyau et la tête du filtre.

L’adaptateur, auquel sont reliés les tuyaux possède sur sa partie de dessous deux joints toriques qui servent à rendre la tête du filtre bien étanches.

Si ceux-ci sont sales, tordus ou endommagés ou ont glissés et sont mal placés, ils ne sont plus pressés sur la tête du filtre et l’eau peut pénétrer à partir de là dans la tête du filtre d’aquarium.

L’endroit où l’eau sort est alors la partie la plus basse de la tête du filtre, celle où l’on trouve les deux clips de fermeture de côté, et qui raccordent la tête du filtre avec le réservoir.

Cette panne est très rapidement réparée.

Veuillez simplement nettoyer les joints toriques et les contrôler. Il est aussi important de regarder la partie où les joints sont insérés dans la tête du filtre, pour

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 8

vérifier qu’elle est absolument propre. C’est un endroit où des algues peuvent se former ou du sable s’accumuler, si on ne procède pas à un entretien régulier.

Ce problème peut aussi se poser en cas de toute première installation par du sable qui s’y dépose.

Veuillez prendre votre temps pour procéder au nettoyage, si vous ne travaille pas avec assez de soin, il est possible que le filtre ne soit pas entièrement étanche après le nettoyage.

Si malgré un entretien soigneux l’eau continue de sortir à l’endroit nommé plus haut, veuillez contrôler le positionnement des joints toriques à l’intérieur de l’adaptateur. Pour cela vous devrez l’ouvrir . Contactez alors notre service aprèsventes.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 9

1

Tubes d'entrées et d'écoulement de l'eau

2 Tête du filtre

3 Bac

4 Tube UV

5 Couvercle du filtre

6 Paniers filtre

Matériaux filtre

7 Coude d'écoulement

8 Tube de connection

9 Conduite d'entrée

10

Embout de conduite d'entrée

11 Entrée de l'eau sale

12 Tube de connection

13 Coude d'entrée

14 T d'entrée des saletés

15 Conduite de sortie

16 Panier d'écoulement

17 Ventouses de fixation

18 Tuyaux

Anneaux céramique Charbon actif

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Tapis japonais Boules biologiques

Seite 10

Matériaux filtre – Informations de base

Les matériaux filtre inclus dans la livraison sont un équipement de base.

Veuillez vous informer, pour savoir quels sont les filtres qui conviennent tout particulièrement à votre type d’aquarium, car cela peut varier selon les poissons et les plantes qui sont à l’intérieur.

N’utilisez la ouate filtrante que pour une étape de filtration et changez-la régulièrement car un tissu de filtration qui est sale et bouché peut vite mener à une baisse de la puissance de filtration du filtre.

Les filtres extérieurs sont composés de plusieurs couches. L’eau aspirée est donc filtrée en plusieurs étapes.

La partie la plus basse est faite de boules biologiques. Elle offre aux bactéries utiles une surface importante pour une colonisation et retient les particules de saleté grossières. Placez au-dessus de cette couche, une couche de ouate ou tissu filtrant. Puis comme troisième couche des petits anneaux filtre en céramique. Ceux-ci offrent de la place aux bactéries utiles.

En plus vous avez aussi la possibilité de placer une couche de charbon filtre (à acheter en filet ou comme tapis), qui est donc la dernière couche. Celle-ci ne doit pas être utilisée constamment mais seulement après un traitement aux médicaments ou quand l’eau est trouble à cause de matières en suspension.

En cas de toute nouvelle mise en marche d’un filtre d’aquarium ou après un nettoyage complet, vos devrez enrichir le filtre de bactéries utiles. Il existe pour cela des cultures spéciales de bactéries à acheter, que l’on peut mettre directement dans le filtre pour faciliter le départ.

Veuillez donc utiliser du bas en haut:

1.Etape: Filtration mécanique / en partie biologique

2.Etape: Filtration biologique

3.Etape: Filtration chimique (Charbon actif, tourbe, phosphate, par ex. etc.)

En cas de filtre à 4 étapes vous pouvez au choix agrandir votre filtration par une

étape mécanique ou une étape biologique supplémentaire.

© by WilTec Wildanger Technik GmbH http://www.wiltec.info

Seite 11

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement