Duluth Forge 170041 28 in. 15000 BTU T-Stat Control Ventless Dual Fuel Fireplace in Apple Spice with Mantel Owner's Operation And Installation Manual

Add to My manuals
32 Pages

advertisement

Duluth Forge 170041 28 in. 15000 BTU T-Stat Control Ventless Dual Fuel Fireplace in Apple Spice with Mantel Owner's Operation And Installation Manual | Manualzz

VENT-FREE GAS

FIREPLACE INSERT

OWNER’S OPERATION AND

INSTALLATION MANUAL

MODEL

FDF150T

PFS

®

US

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your building.

• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

— Installation and service must be performed by a qualified installer, service agency or the gas supplier.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-855-607-6557, 8:00 am - 4:30 pm EST,

Monday through Friday or email [email protected]

TABLE OF CONTENTS

Safety ........................................................ 3

Qualified Installing Agency ........................ 4

Specifications ............................................ 5

Product Features ....................................... 5

Local Codes............................................... 5

Unpacking.................................................. 6

Product Identification ................................. 6

Water Vapor: A By-Product Of

Unvented Room Heaters ..................... 6

Air For Combustion and Ventilation ........... 7

Installation ................................................. 9

Operation ................................................. 18

Inspecting Burners................................... 21

Care And Maintenance ............................ 22

Troubleshooting ....................................... 24

Parts ........................................................ 28

Replacement Parts .................................. 30

Accessories ............................................. 30

Service Hints ........................................... 31

Technical Service..................................... 31

Warranty .................................................. 32

SAVE THIS BOOK

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided.

Refer to Air For Combustion and Ventilation section on page 7 of this manual.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with propane or natural gas. Field conversion by any other means including the use of a kit is not permitted.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.

2

PATENT INFORMATION

This product may be covered by one or more of the following United States patents:

8,915,239 8,851,065 8,764,436 8,757,202 8,757,139 8,752,541 8,568,136

8,545,216 8,517,718 8,516,878 8,506,290 8,465,277 8,317,511 8,297,968

8,281,781 8,241,034 8,235,708 8,152,515 8,011,920 7,967,006 7,967,007

7,654,820 7,730,765 7,677,236 7,607,426 7,434,447 www.factorybuysdirect.com

200200-01B

SAFETY

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this heater.

Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock and carbon monoxide poisoning. Failure to follow these instructions will void the warranty.

Only a qualified installer, service agent, or local gas supplier may install and service this product.

WARNING: Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

WARNING: This appliance can be used with propane or natural gas. It is shipped from the factory adjusted for use with propane.

DANGER: Carbon monoxide poisoning may lead to death!

CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea.

If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes.

NATURAL AND PROPANE/LP GAS: Natural and Propane/LP gas are odorless. An odormaking agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

WARNING: Any change to this heater or its controls can be dangerous.

200200-01B www.factorybuysdirect.com

WARNING: Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house.

To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.

WARNING: Do not allow fans to blow directly into fireplace.

Avoid any drafts that alter burner flame patterns.

WARNING: Do not use a blower insert, heat exchange insert or other accessory not approved for use with this heater.

WARNING: Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

WARNING: Clothing or other flammable material should not be placed on or near the appliance. Never place any objects in the heater.

WARNING: Heater becomes very hot when running. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching.

3

WARNING: You must operate this heater with screen in place.

Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance.

1. Do not place Propane/LP supply tank(s) inside any structure. Propane/LP supply tank(s) must be placed outdoors.

2. This heater shall not be installed in a bedroom or bathroom.

3. This heater needs fresh air ventilation to run properly. This heater has an Oxygen

Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See

Air for Combustion and Ventilation, pages

7 and 8. If heater keeps shutting off, see

Troubleshooting, page 24.

4. Keep all air openings in front and bottom of heater clear and free of debris. This will ensure enough air for proper combustion.

5. If heater shuts off, do not relight until you have provided fresh, outside air. If heater keeps shutting off, have it serviced.

6. Do not run heater:

• Where flammable liquids or vapors are used or stored.

• Under dusty conditions.

7. Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off.

If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.

SAFETY

8. Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

9. Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater.

10. Operating heater above elevations of

4,500 feet could cause pilot outage.

11. To prevent performance problems, do not use propane/LP fuel tank of less than

100 lbs. capacity.

12. Do not use this heater as a wood-burning heater. Use only the logs provided with the heater.

13. Do not operate heater if any log is broken.

Do not operate heater if any log is chipped

(dime-sized or larger).

14. To prevent sooting, follow the instructions in Care and Maintenance (see page 22).

15. Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool.

Using these added items can cause sooting. Do not add lava rock around base.

Rock and debris could fall into the control area of heater. After servicing, always replace screen before operating heater.

16. This heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified service person.

Note: During initial operation, slight smoking could occur due to log curing and the heater burning manufacturing residues.

QUALIFIED INSTALLING AGENCY

Only a qualified agency should install and replace gas piping, gas utilization equipment or accessories, and repair and equipment servicing. The term “qualified agency” means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for:

a) Installing, testing, or replacing gas piping or

b) Connecting, installing, testing, repairing, or servicing equipment; that is experienced in such work; that is familiar with all precautions required; and that has complied with all the requirement of the authority having jurisdiction.

4 www.factorybuysdirect.com

200200-01B

SPECIFICATIONS

Model FDF150T

Gas Type Natural Gas Propane Gas

Maximum Input Rating 15,000 Btu/Hr 15,000 Btu/Hr

Minimum Input Rating 7,000 Btu/Hr 11,000 Btu/Hr

Pressure Regulator Setting 4" W.C.

9" W.C.

Inlet Gas Pressure*

(inches of water)

Max. 10"

Min. 5"

Max. 14"

Min. 11"

Ignition Electronic Piezo

Heater Dimensions (WxHxD) • 16" × 27.7" × 10.75"

Carton Dimensions (WxHxD) • 18.9" × 30.79" × 13.25"

Heater Weight • 38 lbs

Shipping Weight • 41.3 lbs

* For purposes of input adjustment.

PRODUCT FEATURES

SAFETY PILOT

This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The

ODS/pilot shuts off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater is equipped with an electronic piezo control system. This system requires one AAA battery (provided).

THERMOSTATIC CONTROL

The control automatically cycles the burner on and off to maintain a desired room temperature.

2 GAS OPTIONS AVAILABLE

Your heater is equipped to operate on either

Propane/LP or Natural gas. The heater is shipped from the factory ready for connecting to Propane/LP. The heater can easily be changed to Natural gas by having your qualified installer follow the instructions on page

10 and the markings on the heater.

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel

Gas Code, ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

1 Batterymarch Park

Quincy, MA 02269-9101

This heater is designed for vent-free operation. State and local codes in some areas prohibit the use of vent-free heaters.

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527

CMR 30 upon sale of the unit.

In the State of Massachusetts the gas cock must be a T-handle type. The State of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length.

200200-01B www.factorybuysdirect.com

5

1. Remove top inner pack.

2. Tilt carton so that heater is upright.

3. Remove protective side packaging.

4. Slide heater out of carton.

5 Remove protective plastic wrap.

6. Hold the screen, lift, and pull forward.

UNPACKING

7. Remove log set by cutting plastic ties.

8. Carefully unwrap log.

9. Check for any shipping damage. If heater or log is damaged, promptly inform your dealer where you bought the heater.

PRODUCT IDENTIFICATION

Front Panel

Hood

Screen

Heater Controls

(Behind Panel)

Figure 1 - Vent-Free Fireplace Insert

WATER VAPOR: A BY-PRODUCT OF

UNVENTED ROOM HEATERS

Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30 mL) of water for every 1,000 BTUs (0.3 KWs) of gas input per hour. Unvented room heaters are recommended as supplemental heat (a room) rather than a primary heat source (an entire house).

In most supplemental heat applications, the water vapor does not create a problem. In most applications, the water vapor enhances the low humidity atmosphere experienced during cold weather.

The following steps will help ensure that water vapor does not become a problem.

1. Be sure the heater is sized properly for the application, including ample combustion air and circulation air.

2. If high humidity is experienced, a dehumidifier may be used to help lower the water vapor content of the air.

3. Do not use an unvented room heater as the primary heat source.

6 www.factorybuysdirect.com

200200-01B

AIR FOR COMBUSTION AND VENTILATION

WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.

Today’s homes are built more energy efficient than ever. New materials, increased insulation and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in.

During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.

Exhaust fans, fireplaces, clothes dryers and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.

WARNING: This heater shall not be installed in a room or space unless the required volume of indoor combustion air is provided by the method described in the National Fuel Gas

Code, ANSI Z223.1/NFPA 54, the

International Fuel Gas Code, or applicable local codes.

WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code,

ANSI Z223.1/NFPA 54, the In-

ternational Fuel Gas Code, or applicable local codes.

200200-01B www.factorybuysdirect.com

7

AIR FOR COMBUSTION AND VENTILATION

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options

1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2).

Follow the National Fuel Gas Code, ANSI

Z223.1/NFPA 54, Air for Combustion and

Ventilation for required size of ventilation grills or ducts.

12"

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel

Gas Code, ANSI Z223.1/NFPA 54, Air for

Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

Ventilation

Grills into

Adjoining

Room,

Option 1

Or

Remove

Door into

Adjoining

Room,

Option 3

Ventilation Grills

Into Adjoining Room,

Option 2

Outlet

Air

Outlet

Air

Ventilated

Attic

To Attic

12"

Figure 2 - Ventilation Air from Inside

Building

(Wall installation shown)

To

Crawl

Space

Inlet

Air

Inlet Air

Ventilated

Crawl Space

Figure 3 - Ventilation Air from Outdoors

(Mantel installation shown)

8 www.factorybuysdirect.com

200200-01B

NOTICE: This heater is intended for use as supplemental heat.

Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

INSTALLATION

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form too much moisture.

See Air for Combustion and Ventilation, pages

7 and 8.

CHECK GAS TYPE

Be sure your gas supply is right for your heater. Otherwise, call dealer where you bought the heater for proper type heater.

CLEARANCES TO

COMBUSTIBLES

WARNING: A qualified service person must install heater.

Follow all local codes.

WARNING: Never install the heater

• in a bedroom or bathroom.

• in a recreational vehicle

• where curtains, furniture, clothing, or other flammable objects are less than 42" from the front, top, or sides of the heater

• in high traffic areas

• in windy or drafty areas

WARNING: You must maintain the minimum clearances shown in Figure 4. If you can, provide greater clearances from floor, ceiling, and joining wall.

Measure from outermost point of heater.

Minimum Wall and Ceiling

Clearances

A. Clearances from outermost point of heater to any combustible side wall should not be less than 8".

B. Clearances from the heater to the ceiling should not be less than 42".

Note: When heater is installed directly on carpeting, tile or other combustible material, other than wood flooring, the heater must be installed on a metal or wood panel extending the full width and depth of the heater.

CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may cause walls to discolor.

Side

Wall

8"

Min.

Ceiling

42"

Min.

8"

Min.

Side

Wall

Front View

Figure 4 - Minimum Clearances to Wall and Ceiling

200200-01B www.factorybuysdirect.com

9

INSTALLATION

GAS SELECTION

This appliance is factory preset for propane/LP gas.

No changes are required for connecting to propane/LP.

Only a qualified installer or service technician can perform gas selection and connecting to gas supply.

Insert Gas Fitting for Propane/LP Gas

CAUTION: Two gas line installations at the same time are prohibited.

CAUTION: To avoid gas leakage for the gas not being used at the inlet of regulator, a qualified installer or service technician must use supplied cap.

You will notice a color coded plunger on the inside of the regulator. This is normal. When the inlet connection fitting is inserted and tightened, this plunger will be pushed back by the fitting making all of the adjustments for the gas being supplied. DO

NOT REMOVE THE PLUNGER.

The regulator will not work.

The inlet regulator is color coded for identification of the correct gas type. Blue is for propane (LP gas) and yellow is for natural gas.

Blue Propane/LP

Gas Plunger

Underneath Dust

Cover

Yellow Natural Gas

Plunger Underneath

Metal Cap

Figure 6 - Gas Regulator

FOR PROPANE/LP GAS

INSTALLATION: BLUE

1. Remove blue dust cover.

Blue Dust

Cover

Insert Gas Fitting for Natural Gas

DO NOT REMOVE

Blue Propane/LP Plunger

Install Gas Fitting Here

Fitting supplied with the product located in the hardware bag. Fitting part number:

160960-02 (straight)

160960-03 (elbow)

Figure 5 - Supplied Fitting

10 www.factorybuysdirect.com

200200-01B

INSTALLATION

2. Apply thread sealant to the threads on the connection fitting. While pushing in, rotate the fitting clockwise until the threads engage the regulator. After the fitting has been hand tightened into the regulator use a wrench to complete tightening of the fitting. Install additional fitting to connect to the house supply.

Use only the cap supplied on the regulator. Do not use an off the shelf pipe plug. This can damage the plunger. The supplied regulator cap is designed so it will not engage the unused gas type.

4. Apply thread sealant to the threads on the connection fitting. While pushing in, rotate the fitting clockwise until the threads engage the regulator. After the fitting has been hand tightened into the regulator use a wrench to complete tightening of the fitting. Install additional fitting to connect to the house supply.

FOR NATURAL GAS (NG)

INSTALLATION: YELLOW

1. Remove the blue dust cover from the regulator.

2. Remove the metal cap installed over the

NG regulator inlet.

Metal Cap

3. Install metal cap over LP/Propane regulator inlet. This will keep debris out of regulator.

Metal Cap

DO NOT REMOVE

Yellow Natural Gas Plunger

Install Gas Fitting Here

Back of Fireplace

DO NOT use an off the shelf 3/8"

NPT pipe plug. This will damage the plungers located inside the regulator.

DO NOT try to remove the plungers from inside the regulator. The plunger will be pushed back as the fitting is installed.

Make sure the type of gas being used is correct. Check to make sure the connection fitting is in the correct inlet on the regulator. Refer to Connecting to Gas

Supply, page 14.

If you are using natural gas and the pilot will not light, see

Troubleshooting, page 24.

200200-01B www.factorybuysdirect.com

11

INSTALLATION

BUILT-IN FIREPLACE INSTALLATION

WARNING: Do not allow any combustible materials to overlap the firebox front.

WARNING: Do not allow combustible or noncombustible materials to cover any necessary openings like louvered slots.

WARNING: Never modify or cover the louvered slots on the front of the firebox.

Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure.

This makes the front of the fireplace flush with wall. If installing a built-in mantel above the fireplace, you must follow the clearances shown in Figure 7.

NOTICE: Surface temperatures of adjacent walls and mantels become hot during operation. Walls and mantels above the fireplace may become hot to the touch.

If installed properly, these temperatures meet the requirement of the national product standard.

Follow all minimum clearances shown in this manual (see Figure

4, page 9 and Figure 8).

1. Frame in rough opening. Use dimensions shown in Figure 9 for the rough opening.

If installing in a corner, use dimensions shown in Figure 10 (page 13) for the rough opening. The height is 19", which is the same as the wall opening above.

2. Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.

1/4" Clearance to Facia

3/8" Clearance to Sides, Back and Top

15 5 /

16"

8

"

Figure 7 - Clearance to Combustibles

To

Ceiling

Fireplace

3"

6"

Safe Zone

12"

9"

1 1 /

2

"

Hood Top

9 1 /

4

"

1 3 /

4

"

Slope

Factor

Figure 8 - Fireplace Clearances

11"

15 5 /

8

"

Figure 9 - Rough Opening for Wall

Installation

12 www.factorybuysdirect.com

200200-01B

INSTALLATION

3. Attach gas line to fireplace gas regulator.

See Connecting to Gas Supply, page 14.

4. Check all gas connections for leaks. See

Checking Gas Connections, page 16.

IMPORTANT: When finishing your firebox, combustible materials such as wall board, gypsum board, sheet rock, drywall, plywood, etc, must have 1/2" clearance to the sides and top of the firebox. Combustible materials should never overlap the firebox front facing.

1

25

/

8

" 90°

15 5 /

8

"

36 1 /

2

"

Figure 10 - Rough Opening for Corner

Installation

CABINET MANTEL

If using a cabinet mantel, assemble following the instructions included with the mantel at this time.

Note: Some mantels are designed with physical and chemical distress to enhance the realistic appearance of the wood.

1. Carefully push the fireplace insert into the mantel from the front as shown in

Figure 11.

2. Position the fireplace against the wall in the desired location.

200200-01B

Figure 11 - Installing Fireplace Insert Into

Mantel www.factorybuysdirect.com

13

14

INSTALLATION

CONNECTING TO GAS SUPPLY

WARNING: A qualified service technician must connect heater to gas supply. Follow all local codes.

CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting into gas piping and/or fittings.

WARNING: This appliance requires a 3/8" NPT (National

Pipe Thread) inlet connection to the pressure regulator.

WARNING: For natural gas,

Never connect heater to private

(non-utility) gas wells. This gas is commonly known as wellhead gas.

WARNING: Do not overtighten gas connections.

CAUTION: Use only new, black iron or steel pipe. Internally tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of

1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

CAUTION: For natural gas, check your gas line pressure before connecting heater to gas line. Gas line pressure must be no greater than 9" of water. If gas line pressure is higher, heater regulator damage could occur.

CAUTION: For propane/

LP gas, never connect heater directly to the gas supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and gas supply.

CAUTION: Use pipe joint sealant that is resistant to gas

(Propane/LP or Natural Gas).

Before installing heater, make sure you have the items listed below:

• external regulator for propane/LP unit only

(supplied by installer)

• piping (check local codes)

• sealant (resistant to natural gas and propane/LP gas)

• equipment shutoff valve*

• test gauge connection*

• sediment trap

• tee joint

• pipe wrench

• flexible gas hose (check local codes)

* A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design certified equipment shutoff valve from your dealer.

Typical Inlet Pipe Diameters

Use 3/8" black iron pipe or greater. Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure

12, page 15).

IMPORTANT: Install an equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

For propane/LP installations, apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe.

Excess sealant in pipe could result in clogged heater valves.

www.factorybuysdirect.com

200200-01B

INSTALLATION

The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11" and 14" of water.

If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 13. Pointing the vent down protects it from freezing rain or sleet.

Ground

Joint Union

3/8" NPT

Pipe Nipple

Install sediment trap in supply line as shown in Figure 12. Place sediment trap where it is within reach for cleaning. Place sediment trap where trapped matter is not likely to freeze.

A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

Test Gauge

Connection*

Tee Joint

Reducer

Bushing to

1/8" NPT

1/8" NPT

Plug Tap

Equipment

Shutoff Valve

Natural Gas

From Gas Meter

Propane/LP

Supply Tank

(5" W.C.** to 9"

W.C. Pressure)

External

Regulator with

Vent Pointing

Down

Sediment

Trap

Tee Joint

Pipe Nipple

Gap

3" Minimum

Propane/LP

From External

Regulator

(11" W.C.** to 14" W.C.

Pressure)

Figure 12 - Gas Connection

* Purchase the optional CSA design-certified equipment shutoff valve from your dealer.

Figure 13 - External Regulator with Vent Pointing Down

200200-01B

Gas Regulator

Inlet Connector

Figure 14 - Gas Regulator Location and

Gas Line Access into Stove Cabinet www.factorybuysdirect.com

15

INSTALLATION

WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detection fluid to all joints. If bubbles form, there is a leak. Correct all leaks at once.

CHECKING GAS CONNECTIONS

Test Pressures Equal To or Less Than

1/2 PSIG (3.5 kPa)

1. Close equipment shutoff valve (see Figure 15).

2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.

3. Check all joints from gas meter to equipment shutoff valve for natural gas or propane/LP supply to equipment shutoff valve for propane/LP (see Figure 16 or

17). Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

4. Correct all leaks at once.

PRESSURE TESTING GAS SUPPLY

PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1. Disconnect heater with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 PSIG will damage heater regulator.

2. Cap off open end of gas pipe where equipment shutoff valve was connected.

3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.

4. Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to all joints. If bubbles form, there may be a leak.

5. Correct all leaks at once.

6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

Propane/LP

Supply Tank

Equipment

Shutoff Valve

External Regulator with

Vent Pointing Down

Control Valve

Location

Figure 16 - Checking Gas Joints for

Propane/LP Gas

Equipment

Shutoff Valve

Open Gas Meter

Closed

Figure 15 - Equipment Shutoff Valve Equipment Shutoff Valve

Control Valve

Location

Figure 17 - Checking Gas Joints for

Natural Gas

16 www.factorybuysdirect.com

200200-01B

INSTALLATION

PRESSURE TESTING HEATER GAS CONNECTIONS

1. Open equipment shutoff valve (see Figure

15, page 16).

2. Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.

3. Make sure control knob of heater is in the

OFF position.

4. Check all joints from equipment shutoff valve to control valve (see Figure 16 or

17, page 16). Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5. Correct all leaks at once.

6. Light heater (see Lighting Instructions on page 19). Check all other internal joints for leaks.

7. Turn off heater (see To Turn Off Gas Ap-

pliance, page 20).

INSTALLING LOGS

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

IMPORTANT: Make sure logs do not cover any burner ports. It is very important to install the logs exactly as instructed. Do not modify logs. Use only logs supplied with heater.

Log #1

CAUTION: After installation, and periodically thereafter, check to ensure that no flame comes in contact with any log.

With the heater set to high, check to see if flames contact any log. If so, reposition logs according to the log installation instructions in this manual. Flames contacting logs will create soot.

1. Install log #1 on the rear plate as shown in Figure 19.

2. Install logs #2 and #3 as shown in Figure 20.

3. Install log #4 and log #5 as shown in

Figure 21.

Rear Plate

Figure 19 - Installing Log #1

Log #2 Log #3

Figure 20 - Installing Logs #2 and #3

Log #5

Log #4

Figure 18 - Stove Cabinet

(Brick liner not shown)

200200-01B

Figure 21 - Installing Log #3 & #4 www.factorybuysdirect.com

17

INSTALLATION

BATTERY INSTRUCTIONS

CAUTION: Do not dispose of batteries in fire, batteries may explode or leak.

• Battery is included.

• Remove battery when depleted.

• Be sure to observe proper polarity (+/-) when installing or replacing the battery.

Damage due to improper battery installation may void the warranty on the product.

• For long periods of non-operation, remove batteries from all components for safety.

Unscrew ignitor cap and install a AAA battery with the + pointing out. Replace cap.

AAA

Battery

Positive

UP

Figure 22 - Installing Battery in Ignitor

OPERATION

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do not use any phone in your building.

• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to push in or turn the gas control knob. Never use tools.

If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

18 www.factorybuysdirect.com

200200-01B

OPERATION

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell.

Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

LIGHTING INSTRUCTIONS

WARNING: You must operate this heater with the screen in place. Make sure screen is installed before running heater.

1. STOP! Read the safety information above.

2. Unscrew ignitor cap and install a AAA battery with the + pointing out. Replace cap.

3. Make sure equipment shutoff valve is fully open.

4. Turn control knob clockwise to the

OFF position.

5. Wait five (5) minutes to clear out any gas.

Then smell for gas around heater and near the floor. If you smell gas, STOP! Follow

"B" in the safety information above. If you do not smell gas, go to the next step.

6. Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 23).

Note: The first time that the heater is operated after connecting the gas supply,the control knob should be pressed for about thirty (30) seconds. This will allow air to bleed from the gas system. If pilot does not stay lit, refer to Troubleshooting, pages 24 though 27. Also contact a qualified service technician or gas supplier for repairs. Until repairs are made, light pilot with match.

• If control knob does not pop up when released, contact a qualified service technician or gas supplier for repairs.

7. With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the rear of the front of burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to

Troubleshooting, pages 24 though 27.

Also contact a qualified service technician or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting

Procedure, page 20.

8. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.

9. Turn control knob counterclockwise to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO (5 and 1).

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

WARNING: If input gas type is NG, make sure NG pilot burner ignites. If input gas type is LP, make sure LP pilot burner ignites.

Control Knob Ignitor Button

Figure 23 - Control Knob in the OFF

Position

200200-01B www.factorybuysdirect.com

19

OPERATION

THERMOSTAT CONTROL OPERATION

The thermostatic control used on this model differs from standard thermostats. Standard thermostats simply turn the burner on and off.

The thermostat used on this heater senses the room temperature. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any comfort level between HIGH (5) and LOW (1).

Note: The thermostat sensing bulb measures the temperature depending on housing construction.

TO TURN OFF GAS TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise

OFF position.

to the

Shutting Off Burner Only (pilot stays lit )

Turn control knob clockwise

PILOT position.

to the

MANUAL LIGHTING PROCEDURE

1. Remove screen by lifting and pulling forward.

2. Follow steps 1 through 5 under Lighting

Instructions, page 19.

3. With control knob in PILOT position, strike match, and hold near pilot. Press in control knob; pilot should light.

4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

5. Make sure the heater screen is in place before operating heater.

20 www.factorybuysdirect.com

200200-01B

INSPECTING BURNERS

IMPORTANT: Owner’s should check pilot flame pattern and burner flame pattern often.

Incorrect flame patterns indicate the need for cleaning (see Care and Maintenance, page 22) or service.

WARNING: Only a qualified service person should service and repair heater. This includes maintenance requiring replacement or alteration of components.

PILOT FLAME PATTERN

Figure 24 shows a correct pilot flame pattern.

Figure 25 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool, which shuts the heater off.

If pilot flame pattern is incorrect, as shown in Figure 25

• turn heater off (see To Turn Off Gas to Ap-

pliance, page 20)

• see Troubleshooting pages 24 through 27.

WARNING: If yellow tipping occurs, your heater could produce increased levels of carbon monoxide. If the burner flame pattern shows yellow tipping, follow instructions below.

Notice: Do not mistake orange flames with yellow tipping. Dirt or other fine particles enter the heater and burn causing brief patches of orange flame.

Natural Gas

Shown

Natural Gas

Shown

NG

3-3.5" WC

LP

8-11" WC

NG

3-3.5" WC

Approx. 3"-6" Above Top of Logs

LP

8-11" WC

Figure 24 - Correct Pilot Flame Pattern

(Natural Gas shown)

Figure 25 - Incorrect Pilot Flame Pattern

(Natural Gas shown)

BURNER FLAME PATTERN

Figure 26 shows a correct burner flame pattern. Figure 27 shows an incorrect burner flame pattern. If burner flame pattern is incorrect then:

• turn heater off (see To Turn Off Gas to Appliance, page 20).

• see Troubleshooting pages 24 through 27.

More Than 8" Above Top of Logs

Approx. 3"-6" Above Top of Logs

Figure 26 - Correct Burner Flame Pattern with Control Knob Set to HI (5)

Figure 27 - Incorrect Burner Flame

Pattern with Control Knob Set to HI (5)

BURNER PRIMARY AIR HOLES

Air is drawn into the burner through the holes in the fitting at the entrance to the burner. These holes may become blocked with dust or lint. Periodically inspect these holes for any blockage and clean as necessary. Blocked air holes will create soot.

200200-01B www.factorybuysdirect.com

21

CARE AND MAINTENANCE

WARNING: Turn off heater and let cool before servicing.

CAUTION: You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service technician. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off the heater and let it cool, and remove blockage or replace burner. Blocked burner flame holes will create soot.

CLEANING BURNER PILOT AIR INLET HOLE

We recommend that you clean the unit every 2,500 hours of operation or every three months. We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSl. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don’t follow directions on the can, you could damage the pilot assembly.

1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2. Inspect burner, pilot and primary air inlet holes on injector for dust and dirt (see

Figure 28).

3. Blow air through the ports/slots and holes in the burner. Also clean the pilot assembly.

4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.

5. Blow air into the primary air holes on the injector holder.

6. In case any large clumps of dust have now been pushed into the burner. Repeat steps

3 and 4.

Burner

Tube

Primary Air Inlet Holes Injector

Figure 28 - Burner and Injector Holder

22 www.factorybuysdirect.com

200200-01B

CARE AND MAINTENANCE

ODS/PILOT

CAUTION: Never use a wire, needle, or similar object to clean

ODS/pilot. This can damage

ODS/ pilot unit.

Natural Gas

Burner

Ignitor

Electrode

Thermocouple

Propane/LP

Gas Burner

Use a vacuum cleaner, pressurized air, or a small, soft bristled brush to clean.

A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about 2" from where the pilot flame comes out of the pilot assembly

(see Figure 29). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Pilot Air

Inlet Hole

Pilot Air Inlet Hole

Figure 29 - Pilot Inlet Air Hole

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

• Use a soft cloth dampened with a mild soap and water mixture.

• Wipe the cabinet to remove dust.

LOGS

• If you remove logs for cleaning, refer to Installing Logs, page 17, to properly replace logs.

• Replace log(s) if broken or chipped (dime-size or larger).

200200-01B www.factorybuysdirect.com

23

TROUBLESHOOTING

WARNING: If you smell gas:

• Shut off gas supply.

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your building.

• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

WARNING: Only a qualified service technician should service and repair heater. Make sure that power is turned off before proceeding.

Turn off and let cool before servicing.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

Note: All troubleshooting items are listed in order of operation.

Problem

Using natural gas and pilot will not light.

Possible Cause Corrective Action

Inlet pressure exceeds 10" WC. Bypass pressure switch. See instructions below.

Pressure Switch

When using natural gas (NG), there is a pressure switch that acts to turn off the gas flow to the pilot if the inlet pressure exceeds 10" WC.

This is to prevent the operation of the unit on the wrong gas (propane/LP). If your natural gas supply exceeds 10" WC the unit will not operate. Either contact your gas supplier to check and adjust the inlet pressure or a qualified service technician can bypass the pressure switch.

Before attempting to bypass the pressure switch, make sure the type of gas being used is correct. Check to make sure the connection fitting is in the correct inlet on the regulator.

Refer to Connecting to Gas Supply, page 14

Only a qualified installer should bypass the pressure switch. To bypass the pressure switch locate the set screw on the regulator.

Use a small flat bladed screw driver to turn the set screw counterclockwise 2 turns. This will bypass the pressure switch function.

The entire gas delivery piping including connections inside the heater should be leak tested by the qualified installer. After leak testing the qualified installer should light the appliance. Refer to the correct flame pattern as illustrated on page 21 All flame patterns should be safely inside the product. If for any reason they are not, stop use of the appliance and call for repairs.

NG

Pressure Switch Set Screw

Figure 30 - Gas Regulator Pressure

Switch

24 www.factorybuysdirect.com

200200-01B

TROUBLESHOOTING

Problem

When ignitor button is pressed in, there is no spark at ODS/pilot

When ignitor button is pressed in there is a spark at ODS/pilot but no pilot flame present.

ODS/pilot lights but flame goes out when control knob is released.

Possible Cause

1. Ignitor electrode is positioned wrong. Ignitor electrode is broken.

2. Ignitor electrode is not connected to ignitor cable.

3. Ignitor cable is pinched or wet.

Corrective Action

1. Replace electrode.

2. Replace ignitor cable

4 Broken ignitor cable.

5. Bad piezo ignitor.

6. Low battery.

1. Gas supply is turned off or equipment shutoff valve is closed.

2. Control knob not fully pressed in while pressing ignitor button.

3. Air in gas lines (new installation or recent gas interruption).

4. ODS / pilot is clogged.

5. Incorrect inlet gas pressure or inlet regulator is damaged.

6. Control knob not in PILOT position.

7. Depleted gas supply (propane).

1. Control knob is not fully pressed in.

2. Control knob is not pressed in long enough.

3. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry.

4. Replace ignitor cable.

5. Replace piezo ignitor.

6. Replace battery.

1. Turn on gas supply or open equipment shutoff valve.

2. Fully press in control knob while pressing ignitor button.

3. Continue holding down control knob. Repeat igniting operation until air is removed.

4. Clean ODS/pilot (see Care

and Maintenance, page 22) or replace ODS/pilot assembly.

5. Check inlet gas pressure or replace inlet gas regulator.

6. Turn control knob to PILOT position.

7. Contact local propane/LP gas company.

1. Press in control knob fully.

3. Equipment shutoff valve is not fully open.

4. Thermocouple connection is loose at control valve.

5. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following:

A) Low gas pressure

B) Dirty or partially clogged

ODS/pilot

6. Thermocouple damaged.

7. Control valve damaged.

2. After ODS/pilot lights, keep control knob pressed in 30 seconds.

3. Fully open equipment shutoff valve.

4. Hand tighten until snug, and then tighten 1/4 turn more.

5. A) Contact local natural or propane/LP gas company

B) Clean ODS/pilot (see

Care and Maintenance, page 22) or replace ODS/ pilot assembly

6. Replace thermocouple.

7. Contact customer service.

200200-01B www.factorybuysdirect.com

25

TROUBLESHOOTING

Problem

Burner(s) does not light after ODS/pilot is lit

Delayed ignition of burner(s).

Burner backfiring during combustion

High yellow flame during burner combustion

Gas odor during combustion.

Slight smoke or odor during initial operation

Heater produces a whistling noise when burner is lit..0

Possible Cause

1. Burner orifice is clogged.

Corrective Action

1. Clean burner orifice (see

Care and Maintenance, page 22) or replace burner orifice.

2. Replace burner orifice.

2. Burner orifice diameter is too small.

3. Inlet gas pressure is too low.

1. Manifold pressure is too low.

2. Burner orifice is clogged.

1. Burner orifice is clogged or damaged.

2. Burner is damaged.

3. Gas regulator is damaged.

1. Not enough air.

2. Gas regulator is defective.

3. Inlet gas pressure is too low.

1. Foreign matter between control valve and burner.

2. Gas leak. (See Warning

Statement at top of page 24).

1. Residues from manufacturing process.

1. Turning control knob to high

(5) position when burner is cold.

2. Air in gas line.

3. Air passageways on heater are blocked.

4. Dirty or partially clogged burner orifice.

3. Contact local gas supplier.

1. Contact local gas supplier.

2. Clean burner (see Care and

Maintenance, page 22) or replace burner orifice.

1. Clean burner orifice (see

Care and Maintenance, page 22) or replace burner orifice.

2. Contact dealer or customer service.

3. Replace gas regulator.

1. Check burner for dirt and debris. If found, clean burner

(see Care and Maintenance, page 22).

2. Replace gas regulator.

3. Contact local gas supplier.

1. Take apart gas tubing and remove foreign matter.

2. Locate and correct all leaks

(see Checking Gas Connec-

tions, page 16).

1. Problem will stop after a few hours of operation.

1. Turn control knob to low (1) position and let warm up for a minute.

2. Operate burner until air is removed from line. Have gas line checked by local gas supplier.

3 Observe minimum installation clearances (Figure 4, page 9)

4 Clean burner (see Care and

Maintenance, page 22) or replace burner orifice.

26 www.factorybuysdirect.com

200200-01B

TROUBLESHOOTING

Problem

Heater produces a clicking/ticking noise just after burner is lit or shut off.

White powder residue forming within burner box or on adjacent walls or furniture

Heater produces unwanted odors.

Heater shuts off in use

(ODS operates).

Gas odor exists even when control knob is in

OFF position.

Moisture/condensation noticed on windows.

Possible Cause

1. Metal is expanding while heating or contracting while cooling.

1. When heated, the vapors from furniture polish, wax, carpet cleaners, etc., turn into white powder residue.

1. Heater is burning vapors from paint, hair spray, glues, etc.

See IMPORTANT statement, page 24.

2. Gas leak. See Warning State-

ment at the top of page 24.

3 Low fuel supply.

1. Not enough fresh air is available.

2. Low line pressure.

3. ODS/pilot is partially clogged.

1. Gas leak. See Warning

Statement at top of page 24.

2. Control valve is defective.

1. Not enough combustion/ ventilation air.

Corrective Action

1. This is common with most heaters. If noise is excessive, contact qualified service technician.

1. Turn heater off when using furniture polish, wax, carpet cleaner or similar products.

1. Ventilate room. Stop using odor causing products while heater is running.

2. Locate and correct all leaks

(see Checking Gas Connec-

tions, page 16).

3. Refill supply tank (Propane/

LP models).

1. Open window and/or door for ventilation.

2. Contact local gas supplier.

3. Clean ODS/pilot (see Care

and Maintenance, page 22).

1. Locate and correct all leaks

(see Checking Gas Connec-

tions, page 16).

2. Contact customer service.

1. Refer to Air for Combus-

tion and Ventilation requirements, page 7.

200200-01B www.factorybuysdirect.com

27

1

PARTS

MODEL FDF150T

28

2

19

16

3

4

5

10

15

11

17

9

6

18

7

12

8

14

13 www.factorybuysdirect.com

200200-01B

PARTS

MODEL FDF150T

This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 30 of this manual.

ITEM PART # DESCRIPTION

1 **150PCS102B-01 Front Panel Assembly

2 FDF150T1014-01 Bottom Door Panel

3 F15T103B-01

4 FE32A155B

5 RVD88-Y-4/9

6 ND0310A-400-P

Screen Assembly

Magnet

Regulator

ODS Pilot

7 PIMDN1-01

8 STL1001

9 ML073-04

Ignitor

Thermostat Valve

Ignitor Cable

10 **15PCS1017-01 Regulator Bracket

11 **15PCS1019-01 Control Panel Door

12 **15PCS1016-01 Thermostat Valve Bracket

13 **15PCS2000B-01 Burner Assembly

14 **RVD88-YJ

15 F15T1022-01

16 F15T1023-01

17 F15T1024-01

Connector Assembly

Log #1

Log #2

Log #3

18 F15T1025-01

19 F15T1026-01

Log #4

Log #5

PART AVAILABLE - NOT SHOWN

ML065-01 Thermostat Bulb Clip

150T2009-01 Hardware Package

160960-01

160960-02

Inlet Cover Assembly

Valve Fitting Assembly

** Not a field replaceable part.

1

1

1

1

1

1

2

1

1

1

2

QTY

1

1

1

1

1

1

1

1

2

1

1

1

200200-01B www.factorybuysdirect.com

29

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product.

If they can’t supply original replacement parts, call Customer Service toll free at

1-855-607-6557 for referral information.

• Model and serial number of your heater

• How heater was malfunctioning

• Type of gas supply and Propane/LP tank size

When calling Customer Service or your dealer, have ready:

• Purchase date

Usually, we will ask you to return the defective part to the factory

• Your name

• Your address

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product.

If they can’t supply original replacement part(s) call Customer Service toll free at

1-855-607-6557 for referral information.

When calling Customer Service have ready:

• Model number of your heater

• The replacement part number

ACCESSORIES

To purchase heater accessories and parts call Factory Buys Direct at 1-855-607-6557.

EQUIPMENT SHUTOFF VALVE

For all models. Visit us online at www.factorybuysdirect.com for a complete selection of gas connection fittings.

MANTELS

Visit us online at www.factorybuysdirect.com for a complete selection of quality fireplace mantels.

30 www.factorybuysdirect.com

200200-01B

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• fireplace will not produce specified heat

• propane/LP gas supply might be low (propane/LP units only)

You may feel your gas pressure is too low. If so, contact your local gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact

Factory Buys Direct at 1-855-607-6557.

When calling, please have your model and serial numbers of your heater ready.

200200-01B www.factorybuysdirect.com

31

WARRANTY

KEEP THIS WARRANTY

Model _______________________________

Serial No. ____________________________

Date Purchased _______________________

Keep receipt for warranty verification.

REGISTER YOUR PRODUCT AT WWW.FACTORYBUYSDIRECT.COM

FACTORY BUYS DIRECT LIMITED WARRANTIES

New Products

Standard Warranty: Factory Buys Direct warrants this new product and any parts thereof to be free from defects in material and workmanship for a period of one (1) year from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with

Factory Buys Direct’s warnings and instructions.

For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from the date of first purchase.

Factory Reconditioned Products

Limited Warranty: Factory Buys Direct warrants factory reconditioned products and any parts thereof to be free from defects in material and workmanship for a period 30 days from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with Factory

Buys Direct’s warnings and instructions. No return will be authorized. Parts will be provided to repair the product.

Terms Common to All Warranties

The following terms apply to all of the above warranties:

Always specify model number and serial number when contacting the manufacturer. To make a claim under this warranty, the bill of sale or other proof of purchase must be presented.

This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, and only when installed by a qualified installer in accordance with all local codes and instructions furnished with this product.

This warranty covers the cost of part(s) required to restore this product to proper operating condition and an allowance for labor when provided by a Factory Buys Direct Authorized Service Center or a provider approved by Factory Buys Direct. Warranty parts must be obtained through authorized dealers of this product and/or Factory Buys Direct who will provide original factory replacement parts. Failure to use original factory replacement parts will void this warranty.

Traveling, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the responsibility of the owner.

Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, improper installation, lack of proper maintenance, tampering or alteration(s).

This is Factory Buys Direct’s exclusive warranty, and to the full extent allowed by law; this express warranty excludes any and all other warranties, express or implied, written or verbal and limits the duration of any and all implied warranties, including warranties of merchantability and fitness for a particular purpose to one

(1) year on new products and 30 days on factory reconditioned products from the date of first purchase.

Factory Buys Direct makes no other warranties regarding this product.

Factory Buys Direct’s liability is limited to the purchase price of the product and Factory Buys Direct shall not be liable for any other damages whatsoever under any circumstances including direct, indirect, incidental, or consequential damages.

Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Factory Buys Direct

500 Brown Industrial Parkway

Canton, GA 30114

1-855-607-6557

200200-01

Rev. B

05/15

advertisement

Related manuals