Linear fittings EVS fluorescent fitting with easy disconnect

Linear fittings EVS fluorescent fitting with easy disconnect
L I N E A R F I T T I N G S - E V S F LU O R E S C E N T F I T T I N G - ZO N E S 1 , 2 , 2 1 & 2 2
59
—
Linear fittings
EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22
Features
• Easy disconnect without wiring to r emove the gear tray
• All components mounted on hinged and r emovable gear
tray for easy maintenance
• Double central locking for ingr ess protection
• Automatic switch off on opening
• Including accessories (cable gland, plugs & fixing brackets)
—
EVS fluorescent fitting with easy disconnect
Approvals & certifications
Specifications
Main body constructed of glass
reinforced polyester for
high impact strength
Exde
UV protected polycarbonate
diffuser to resist harsh
environments
Extb
Rated voltage 108 to 254V ac or dc
G
IIC
D
EOL (End of life) the ballast
prevents the lamp cap at the end of
lamp life cycle from overheating
IIIC
GROUP
1
EN 60079-31 : Enclosure “t”
EN 60079-7 : Increased safety “e”
EC Type examination
certificate to:
2
ZONE
ZONE
21
22
IP66 IK10
LCIE 11 ATEX 3065X
II 2 G
Ex de IIC T4 Gb for -40°C to +60°C
or Ex de IIC T5 Gb for -40°C to +35°C
II 2 D
3x entries M20
2x emergency versions (type: “EM”
version 3h battery duration or
“EMA” with 3h with automatic test
and blackstart capabilities)
Directive 2014/34/EU
IEC Ex LCI 11.0053X
Wiring configuration: 5 wires
ZONE
EN 60079-0 : General requirements
EN 60079-1 : Flameproof enclosure “d”
Instant start
II
ZONE
Standards
Approved to:
Ex tb IIIC T85°C Db IP66 for -40°C to +60°C
EMC Directive
(2004/108/CE) April 2016
(2014/30/UE)
EN 55015 : Conducted emission test
and radiated emission test
EN 61547 : CEM immunity
EN 61000-3-2 : Harmonic current
Emissions Class C
EN 61000-3-3 : Limitation of voltage
changes and flickers
—
01 Easy disconnect
to remove gear tray
Low voltage Directive
(2006/95/CE) - April 2016
(2014/35/UE)
—
02 UV protected
polycarbonate diffuser
—
01
Glow wire test:
—
02
Operating
temperature:
EN 60598-1 : Luminaire general requirements
and tests, including dielectric strength
and isolation resistance
960oC
-20°C to +55ºC EVS,
-10°C to +50ºC EVS EM & EVS EMA
IP test:
IEC 60529: IP66
Impact protection index:
IEC 62262: IK10
60
L I G H T F I T T I N G S , B O X E S & C U S T O M B U I LT C O N T R O L PA N E L S F O R E X P LO S I V E AT M O S P H E R E S
—
Linear fittings
EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22
XFF Tubular Fluorescent fitting
• 5 wires
• Glass Diffuser
• Suitable for use in Zones 1, 2, 21, 22
—
Dimensions
2 x M8 hole 20mm depth
137 mm
C
B
A
170 mm
—
EVS 5 wires: Equipped w with 1 cable gland & 2 plugs
3ODQFRPPHUFLDO
Type For
non armored cable
Dimensions mm
Tol.
Class
3ODQFRPPHUFLDO
armored cable
Tol.
Class
Material
Processing
Drawn by
Description
Scale
Rev
Checked by
Approved by
CUSTOMER
DTS
CE PLAN NE PEUT ETRE COMMUNIQUE OU REPRODUIT MEME PARTIELLEMENT SANS L'AUTORISATION DE DTS
Wiring
Configuration
Light
Rating W
Current A
@ 230V
Material
Processing
Drawn by
Description
Scale
Rev
Checked by
Approved by
CUSTOMER
DTS
CE PLAN NE PEUT ETRE COMMUNIQUE OU REPRODUIT MEME PARTIELLEMENT SANS L'AUTORISATION DE DTS
A
B
C
Weight
kg
EVS120-0000
EVS120-D000
5 wires*
1 x 18
0.09
785
432
400
5.81
EVS140-0000
EVS140-D000
5 wires*
1 x 36
0.17
1 370
900
700
8.60
EVS165-0000
EVS165-D000
5 wires*
1 x 58
0.26
1 670
900
700
10.40
EVS220-0000
EVS220-D000
5 wires*
2 x 18
0.17
785
432
400
5.81
EVS240-0000
EVS240-D000
5 wires*
2 x 36
0.33
1 370
900
700
8.60
EVS265-0000
EVS265-D000
5 wires*
2 x 58
0.50
1 670
900
700
10.40
EVS 5 wires: Equipped w with 2 cable glands & 1 plug
3ODQFRPPHUFLDO
Tol.
EVS120-B000
EVS120-E000
5 wires through**
1 x 18
0.09
785
432
400
5.81
EVS140-B000
EVS140-E000
5 wires through**
1 x 36
0.17
1 370
900
700
8.60
EVS165-B000
EVS165-E000
5 wires through**
1 x 58
0.26
1 670
900
700
10.40
EVS220-B000
EVS220-E000
5 wires through**
2 x 18
0.17
785
432
400
5.81
EVS240-B000
EVS240-E000
5 wires through**
2 x 36
0.33
1 370
900
700
8.60
EVS265-B000
EVS265-E000
5 wires through**
2 x 58
0.50
1 670
900
700
10.40
Class
Material
Processing
Drawn by
Description
Scale
Rev
Checked by
Approved by
CUSTOMER
DTS
CE PLAN NE PEUT ETRE COMMUNIQUE OU REPRODUIT MEME PARTIELLEMENT SANS L'AUTORISATION DE DTS
Note. * For armored cable with 1 continuity plate. ** For armored cable with 2 continuity plates.
Technical information
Lamps
Technical information
Fluorescent Lamp (order separately)
T8 bi-pin tube, lampholder G13, diameter
26mm - white industry 4 000°K
Photometric curve
Rated voltages
Power factor
CRI
Wiring Configuration
Dielectrical class
Grounding system
Terminal block
(spring)
Cable entries
For non-armoured
cable:
See page 189
Electronic ballast: 108 to 254V ac or DC.
EOL (End of life) the ballast prevents the
lamp cap at the end of lamp life cycle from
overheating
0.98
80
For armoured cable:
Housing
5 wires
I
TNS, TNC, TT, IT neutral system
Jumped bar x2 terminal blocks 4mm²
(rigid wire), 2.5mm² (flexible wire)
Terminals supplied L1, L2, L3, N, PE (looping
possible with one additional cable gland)
Fixing
(included with product)
Three entries M20
Included: One 3/4“ nickel plated brass plug
(EXN/075/SP) and one 3/4“nickel plated
brass cable gland for non armoured cable,
diameter 6-12mm (EXN05ASC3)
included continuity plate - two M20 n ylon
plugs (EX-M20) and one M20 nickel plated
brass cable gland, diameter 6-12/ 8.5-16mm
(EXN04MMC1)
Fiberglass reinforced polyester housing for
high impact strength, UV protected
polycarbonate diffuser to resist harsh
environments, Painted steel gear tray &
Stainless steel 316L insert
V015 - 2x Two zinc-plated steel brackets f or
ceiling mounting
L I N E A R F I T T I N G S - E V S E M E M E R G E N C Y F LU O R E S C E N T F I T T I N G - ZO N E S 1 , 2 , 2 1 & 2 2
61
—
Linear fittings
EVS EM Emergency fluorescent fitting with easy disconnect - 3h zones 1, 2 & 21, 22
—
3 wires: Equipped with 1 cable gland & 2 plugs
Type For
Wiring
Configuration
3ODQFRPPHUFLDO
non armored cable
armored cable
Tol.
Class
Material
Processing
Drawn by
Description
Scale
Rev
Checked by
Approved by
CUSTOMER
DTS
CE PLAN NE PEUT ETRE COMMUNIQUE OU REPRODUIT MEME PARTIELLEMENT SANS L'AUTORISATION DE DTS
Light
Rating W
Battery
h
Current A
@ 230V
Dimensions mm
A
B
C
Weight
kg
EVS120EME-0000
EVS120EME-C000
3 wires*
1 x 18
3h
0.09
785
432
400
8.40
EVS140EM-0000
EVS140EM-C000
3 wires*
1 x 36
3h
0.17
1 370
900
700
11.02
EVS165EM-0000
EVS165EM-C000
3 wires*
1 x 58
3h
0.26
1 670
900
700
13.40
EVS220EME-0000
EVS220EME-C000
3 wires*
2 x 18
3h
0.17
785
432
400
8.40
EVS240EM-0000
EVS240EM-C000
3 wires*
2 x 36
3h
0.33
1 370
900
700
11.02
EVS265EM-0000
EVS265EM-C000
3 wires*
2 x 58
3h
0.50
1 670
900
700
13.40
Note. * For armored cable with 1 continuity plate.
For dimensional drawing, please refer to page 60
—
Electrical Features
General data
Lamps
Fluorescent Lamp (order separately)
T8 bi-pin tube, lampholder G13, diameter
26mm - white industry 4 000°K
Photometric curve
See page 189
Rated voltages
Electronic ballast: 108 to 254V ac or DC
EOL (End of life) the ballast prevents the
lamp cap at the end of lamp life cycle from
overheating.
Power factor
0.98
CRI wiring diagram
S EM terminals
EVS EM
Wiring Configuration
Included: One 3/4“ nickel plated brass plug
(EXN/075/SP) and one 3/4“nickel plated
brass cable gland for non armoured cable,
diameter 6-12mm (EXN05ASC3)
For armoured cable:
included continuity plate - two M20 n ylon
plugs (EX-M20) and one M20 nickel plated
brass cable gland, diameter 6-12/ 8.5-16mm
(EXN04MMC1)
Housing
Fiberglass reinforced polyester housing for
high impact strength, UV protected
polycarbonate diffuser to resist harsh
environments, Painted steel gear tray &
Stainless steel 316L insert
4Ah in flameproof case (Ex d)
Lumen output in emergency mode (1 lamp lit)
3 hours: 24% for EVS120, EVS220
3 hours: 18% for EVS140, EVS240
3 hours: 14% for EVS165, EVS265
Monitored by LED
ed loop option —
Switched option
Closed loop option
2
L
E
N
L1
Fixing
(included with product)
V015 - 2x Two zinc-plated steel brackets f or
ceiling mounting
Switched option
Emergency function diagrams
Wiring provided by DTS
Maintained Mode
Terminals supplied L1, L2, L3, N, PE (looping
possible with one additional cable gland)
Three entries M20
For non-armoured
cable:
3 wires
Battery NiCd 7,2V
4mm² (rigid wire), 2.5mm² (flexible wire)
Cable entries
80
terminals wiring diagram
Battery
General data
Terminal block (screws
plug in terminal block)
Switch between L/2
Non Maintained Mode *
Mains Supply
Tube
Battery
Mains Supply
Tube
Battery
ON
Lit
Charging
ON
OFF
Charging
OFF
Only
emergency
tube lit
Discharging
OFF
Only
emergency
tube lit
Discharging
2
L
E
N
L12
1
0
L
E
N
L1
2
L
E
N
L1
1
0
* This table corresponds to the position 0 “open”.
If the switch is on position 1 “close”, refer to the table on the left
L I G H T F I T T I N G S , B O X E S & C U S T O M B U I LT C O N T R O L PA N E L S F O R E X P LO S I V E AT M O S P H E R E S
62
—
Linear fittings
EVS EM Emergency fluorescent fitting with automatic test
& blackstart capabilities - zones 1, 2 & 21, 22
—
5 wires: Equipped with 1 cable gland & 2 plugs
Type For
non armored cable
3ODQFRPPHUFLDO
armored cable
Tol.
Class
Material
Processing
Drawn by
Description
Scale
Rev
Checked by
Approved by
CUSTOMER
DTS
CE PLAN NE PEUT ETRE COMMUNIQUE OU REPRODUIT MEME PARTIELLEMENT SANS L'AUTORISATION DE DTS
Wiring
Configuration
Light
Rating W
Battery
h
Dimensions mm
Current A
@ 230V
A
B
C
Weight
kg
EVS120EMA-0000
EVS120EMA-D000
5 wires*
1 x 18
3h
0.09
785
432
400
8.80
EVS140EMA-0000
EVS140EMA-D000
5 wires*
1 x 36
3h
0.17
1 370
900
700
11.02
EVS220EMA-0000
EVS220EMA-D000
5 wires*
2 x 18
3h
0.17
785
432
400
8.80
EVS240EMA-0000
EVS240EMA-D000
5 wires*
2 x 36
3h
0.33
1 370
900
700
11.02
Note. * For armored cable with 1 continuity plate.
For dimensional drawing, please refer to page 60
Electrical Freatures
Electrical Freatures
Lamps
Fluorescent Lamp (order separately)
Terminal block (spring)
Jumped bar x2 terminal blocks 4mm² (rigid
wire), 2.5mm² (flexible wire)
T8 bi-pin tube, lampholder G13, diameter
26mm - white industry 4 000°K
Photometric curve
Rated voltages
Terminals supplied L1, L2, L3, LS, N, E, BS
(looping possible with one additional
cable gland)
See page 189
Electronic ballast: 108 to 254V ac or DC
EOL (End of life) the ballast prevents the
lamp cap at the end of lamp life cycle from
overheating.
Power factor
Cable entries
Three entries M20
For non-armoured
cable:
included two M20 nylon plugs (EX-M20) and
one M20 nylon cable gland, diameter 6-12mm
(EXCGM20S)
0.98
Wiring Configuration
Battery
For armoured cable:
included continuity plate - two M20 n ylon
plugs (EX-M20) and one M20 nickel plated
Battery NiCd 6V 4Ah in f lameproof
brass cable gland, diameter 6-12/ 8.5-16mm
EVScase
EM A terminals
EVS EM wiring
A terminals
diagram
wiring diagram
(Ex d) for EVS120, EVS220
(EXN04MMC1)
Battery NiCd 6V 7Ah in f lameproof case
Housing
Fiberglass reinforced polyester housing for
loop option
Closed loop option
(Ex d) for EVS140,Closed
EVS240
high impact strength, UV protected
polycarbonate diffuser to resist harsh
Lumen output in emergency mode (1 lamp lit)
environments, Painted steel gear tray &
3 hours: 40% for EVS120, EVS220
Stainless steel 316L insert
E Bs Bs
N N Ls Ls L1 NL1 NL2LsL3Ls E L1 L1 L2 L3 E
3 hours: 33% for EVS140, EVS240E Bs Bs
5 wires
Monitored by two LED
Fixing
(included with product)
V015 - 2x Two zinc-plated steel brackets f or
ceiling mounting
Switch between LS/L1
Mode *
Mains Supply
Tube
Battery
ON
OFF
Charging
—
Emergency function diagrams
EVS EM A terminals
EVS EM wiring
A terminals
diagram
wiring diagram
Wiring provided by DTS
Maintained Mode
Mains Supply
Tube
ON
Lit
Charging
OFF
Only
Discharging
N Ls Ls L1 NL1 NL2LsL3LsE L1 L1 L2 L3 Eemergency
E
Closed loop option
Closed loop option
E Bs Bs
E Bs Bs
N
Battery
Non Maintained
Switched
option Switched
option
OFF
Bs Bs
E
Bs Bs
N
N Ls Ls L1 NL1 NL2LsL3LsE L1 L1 L2 L3 E
tube lit
Only Switched
Discharging
option Switched option
emergency
tube lit
0
1
0
* This table corresponds to the position 0 “open”.
1
If the switch is on position 1 “close”,
refer to the table on the left
EVS EM A terminals wiring diagram
Emergency function diagram Blackstart mode
Switched option Switched option
Preventive maintenance mode
E
Bs
Battery charge - daily
Emergency lamp during 1min - weekly
Bs
Bs Bs
N N Ls Ls L1 NL1 NL2 LsL3LsE L1 L1
BatteryE charge
capacity
during 1hr - quarterly
Clear system test display
Battery charge monitored by 2 LED
0
1
Healthy Emergency or
Test in
(test OK)
Indicator
Progress
Lamp Fault (waiting end
(must be
of test)
replaced)
Fault
(replace
battery)
Switch between BS
terminals
Closed loop option
The EMA product contains 2 blackstart
Switched
option
Switched option
terminals. The blackstart
mode
consists
L2 L3 E
in
disconnecting the ba ttery and so
switching off the fitting. This mode is
mainl y used during maintenance. As
0
soon as the maintenance is done, the
0
main power1ON and the blackstart
terminals connected, the emergency
1
fitting is ready to be used as the ba ttery
is not discharged.
E Bs Bs
N
Mains Supply
Tube
Battery
ON
OFF
Charging
OFF
Only
Discharging
N Ls Ls L1 L1 L2 L3 emergency
E
tube lit
This table corresponds to the position 0 “open”.
Switched option
Switched option
E
Bs Bs
N
N Ls Ls L1 L1 L2 L3 E
L I N E A R F I T T I N G S - E V S F LU O R E S C E N T F I T T I N G - ZO N E S 1 , 2 , 2 1 & 2 2
63
—
Linear fittings - accessories
EVS - zones 1, 2 & 21, 22
Bipin T8 fluorescent lamps
Type
2
Power W Lumen output lm
Lampholder
Specifications
TL18W
18
1 250
G13
G13 - ø 26mm
TL36W
36
3 350
G13
58
5 200
Colour temperature:
White industry 4 000°K
TL58W
ø36
ø20
100
G13
CRI: > 80
25
20
30
ø9
Average operating life: 12 000 hours
18
100
70
30
2 x ø9
60¡
maxi
lm/W: 65 to 93
M8
M8
α
ø9
41
~70
—
Fixing accessories*
60
Brackets
,
2 Ø 8.5
Type
25
ø9
160
200
Specifications
V015
2 x pair of zinc plated steel for ceiling mounting (Included with product)
V016
Stainless steel 316L brackets for ceiling mounting
25
Hook
20
Type
Specifications
V024
2x Zinc plated steel suspension hook
ø36
ø20
100
25
30
18
M
60¡
maxi
M8
M8
α
Hook
60
18
M8
41
~70
* Screws and locknuts supplied
,
Type
Specifications
V014
2x Rapid ceiling mounting with stainless steel clip
Type
Specifications
V018
2x zinc plated steel pole mounted brackets for ø1”¼ & 1”½
V019 25
2 Ø 8.5
~70
,
100
ø9
41
2 Ø 8.5
Fixing bracket and flange
α
ø9
2x zinc plated steel pole mounted brackets for ø2”
V021
2x Stainless steel 316L pole mounted brackets for ø1”¼ & 1”½
V022
2x Stainless steel 316L pole mounted brackets ø2”
64
L I G H T F I T T I N G S , B O X E S & C U S T O M B U I LT C O N T R O L PA N E L S F O R E X P LO S I V E AT M O S P H E R E S
—
Linear fittings - spare parts
EVS - zones 1, 2 & 21, 22
Spare parts
V004
Type
V00120W
20W diffuser with gasket for EV. range
V00140W
40W diffuser with gasket for EV. range
V00165W
65W diffuser with gasket for EV. range
V0041X20WS
Gear tray 1x18W with electronic ballast
220-240Vac/Vdc 50-60Hz for EVS120
V0041X40WS
Gear tray 1X36W with electronic ballast
220-240Vac/Vdc 50-60Hz for EVS140
V0041X65WS
Gear tray 1X58W with electronic ballast
220-240Vac/Vdc 50-60Hz for EVS165
V0042X20WS
Gear tray 2X18W with electronic ballast
220-240Vac/Vdc 50-60Hz for EVS220
V0042X40WS
Gear tray 2x36W with electronic ballast
220- 240Vac/Vdc 50-60Hz for EVS240
V0042X65WS
Gear tray 2x58W with electronic ballast
220- 240Vac/Vdc 50-60Hz for EVS265
V0041X20WEMS
Emergency gear tray 1x18W with electronic ballast
220-240Vac/Vdc 50-60Hz for EVS120EM
V0041X40WEMS
Emergency gear tray 1x36W with electronic ballast
220-240Vac/Vdc 50-60Hz for EVS140EM
V0042X20WEMS
Emergency gear tray 2x18W with electronic ballast
220-240Vac/Vdc 50-60Hz for EVS220EM
V0042X40WEMS
Emergency gear tray 2x36W with electronic ballast
220-240Vac/Vdc 50-60Hz for EVS240EM
V0041X65WEMS
Emergency gear tray 1x58W with electronic ballast
220-240Vac/Vdc 50-60Hz for EVS165EM
V0042X65WEMS
Emergency gear tray 2x58W with electronic ballast
220-240Vac/Vdc 50-60Hz for EVS265EM
V0041X20WEMAS
Emergency gear tray + auto test 1X18W with electronic ballast
220-240Vac/Vdc 50-60Hz for EVS120EMA
V0041X40WEMAS
Emergency gear tray + auto test 1X36W with electronic ballast
220-240Vac/Vdc 50-60Hz for EVS140EMA
V0042X20WEMAS
Emergency gear tray + auto test 2X18W with electronic ballast
220-240Vac/Vdc 50-60Hz for EVS220EMA
V0042X40WEMAS
Emergency gear tray + auto test 2X36W with electronic ballast
220-240Vac/Vdc 50-60Hz for EVS240EMA
V005S
Connection pack: X IN, terminal, track, connector
V001
V008
V005
Specifications
V008
Bi-pin G13 lampholder
V011
Battery pack Ni-Cd 7.2v -4Ah for EVS120EME, EVS220EME,
EVS140EM, EVS240EM
V01120WEMEA
Battery for EVS120EMA, EVS220EMA
V01140WEMEA
Battery for EVS140EMA, EVS240EMA
V02520x40W
Brass continuity plate for EV. 120, EV. 220, EV. 140, EV. 240
V02565W
Brass continuity plate for EV. 165, EV. 265
EXCGM20S
M20 Exe IIC nylon cable gland for non armoured cable diameter 6-12mm,
locknut available separately as LNPB/M20
EXN04MMC1K
Kit M20 Ex-d IIC Ex-e II Ex-td double compression nickel plated cable gland
for armoured cable diameter inner 6-12 outer 8.5-16mm locknut, sealing
gasket