Miller GOLDSTAR 302 Owner Manual

Add to my manuals
44 Pages

advertisement

Miller GOLDSTAR 302 Owner Manual | Manualzz
OM-222
164 850AJ
2009−08
Processes
TIG (GTAW) Welding
Stick (SMAW) Welding
Flux Cored (FCAW) Welding
Air Carbon Arc (CAC-A)
Cutting and Gouging
Description
Arc Welding Power Source
Gold Star Series
CE and non-CE
302, 452, 652 (60 Hz), 402, 602, 852 (50 Hz)
File: Stick (SMAW)
Visit our website at
www.MillerWelds.com
From Miller to You
Thank you and congratulations on choosing Miller. Now you can get
the job done and get it done right. We know you don’t have time to do
it any other way.
That’s why when Niels Miller first started building arc welders in 1929,
he made sure his products offered long-lasting value and superior
quality. Like you, his customers couldn’t afford anything less. Miller
products had to be more than the best they could be. They had to be the
best you could buy.
Today, the people that build and sell Miller products continue the
tradition. They’re just as committed to providing equipment and service
that meets the high standards of quality and value established in 1929.
This Owner’s Manual is designed to help you get the most out of your
Miller products. Please take time to read the Safety precautions. They
will help you protect yourself against potential hazards on the worksite.
We’ve made installation and operation quick
and easy. With Miller you can count on years
of reliable service with proper maintenance.
And if for some reason the unit needs repair,
there’s a Troubleshooting section that will
help you figure out what the problem is. The
Miller is the first welding parts list will then help you to decide the
equipment manufacturer in exact part you may need to fix the problem.
the U.S.A. to be registered to
the ISO 9001:2000 Quality Warranty and service information for your
System Standard.
particular model are also provided.
Miller Electric manufactures a full line
of welders and welding related equipment.
For information on other quality Miller
products, contact your local Miller distributor to receive the latest full
line catalog or individual specification sheets. To locate your nearest
distributor or service agency call 1-800-4-A-Miller, or visit us at
www.MillerWelds.com on the web.
Mil_Thank 4/05
Working as hard as you do
− every power source from
Miller is backed by the most
hassle-free warranty in the
business.
TABLE OF CONTENTS
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
3
1-4. California Proposition 65 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
1-5. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-6. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
4
SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
2-1. Symboles utilisés . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
2-2. Dangers relatifs au soudage à l’arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance . . . . . .
5
7
2-4. Proposition californienne 65 Avertissements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8
2-5. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9
2-6. Informations relatives aux CEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 − DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9
11
3-1. General Precautionary Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
3-2. Input Connection Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-3. Electric Shock And Airflow Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12
12
3-4. Nameplate Safety Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12
3-6. WEEE Label (For Products Sold Within The EU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13
SECTION 4 − INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1. Important Information Regarding CE Products (Sold Within The EU) . . . . . . . . . . . . . . . . . . . . . . . . . . .
14
14
4-2. Serial Number And Rating Label Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14
4-3. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14
4-4. Duty Cycle And Overheating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-5. Volt-Ampere Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15
16
4-6. Selecting A Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17
4-7. Dimensions And Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-8. Tipping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18
19
4-9. 115 VAC Receptacle And Supplementary Protectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19
4-10. Weld Output Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19
4-11. Selecting Cable Sizes* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-12. Connecting Weld Output Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20
21
4-13. Remote 14 Receptacle Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21
4-14. Connecting Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
22
4-15. Electrical Service Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-16. Placing Jumper Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23
24
4-17. Connecting Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25
SECTION 5 − OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-1. Controls (Non CE Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
26
26
5-2. Controls (CE Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27
SECTION 6 − MAINTENANCE AND TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
28
6-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-2. Fuse F1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
28
28
6-3. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
29
SECTION 7 − ELECTRICAL DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30
SECTION 8 − PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPTIONS AND ACCESSORIES
32
WARRANTY
DECLARATION OF CONFORMITY
for European Community (CE marked) products.
MILLER Electric Mfg. Co., 1635 Spencer Street, Appleton, WI 54914 U.S.A. declares that the
product(s) identified in this declaration conform to the essential requirements and provisions of
the stated Council Directive(s) and Standard(s).
Product/Apparatus Identification:
Product
Stock Number
Goldstar 402
Goldstar 602
Goldstar 852
907362
907363
907364
Council Directives:
2006/95/EC Low Voltage
2004/108/EC Electromagnetic Compatibility
Standards:
IEC 60974­1:2005 Arc welding equipment – Part 1: Welding power sources
IEC 60974­10:2007 Arc Welding Equipment – Part 10: Electromagnetic compatibility (EMC) requirements
EN 50445:2008 Product family standard to demonstrate compliance of equipment for resistance welding,
arc welding and allied processes with the basic restrictions related to human exposure to electromagnetic
fields (0 Hz – 300Hz)
US Signatory:
September 1, 2009
__________________________________________________________________________
David A. Werba
Date of Declaration
MANAGER, PRODUCT DESIGN COMPLIANCE
241428­B
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING
som _2009−08
7
Protect yourself and others from injury — read and follow these precautions.
1-1. Symbol Usage
DANGER! − Indicates a hazardous situation which, if
not avoided, will result in death or serious injury. The
possible hazards are shown in the adjoining symbols
or explained in the text.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury. The possible
hazards are shown in the adjoining symbols or explained in the text.
NOTICE − Indicates statements not related to personal injury.
Indicates special instructions.
This group of symbols means Warning! Watch Out! ELECTRIC
SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult symbols and related instructions below for necessary actions to avoid the
hazards.
1-2. Arc Welding Hazards
The symbols shown below are used throughout this manual
to call attention to and identify possible hazards. When you
see the symbol, watch out, and follow the related instructions
to avoid the hazard. The safety information given below is
only a summary of the more complete safety information
found in the Safety Standards listed in Section 1-5. Read and
follow all Safety Standards.
Only qualified persons should install, operate, maintain, and
repair this unit.
During operation, keep everybody, especially children, away.
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shocks
or severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
live when power is on. In semiautomatic or automatic
wire welding, the wire, wire reel, drive roll housing,
and all metal parts touching the welding wire are
electrically live. Incorrectly installed or improperly
grounded equipment is a hazard.
Do not touch live electrical parts.
Wear dry, hole-free insulating gloves and body protection.
Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
Use AC output ONLY if required for the welding process.
If AC output is required, use remote output control if present on
unit.
Additional safety precautions are required when any of the following electrically hazardous conditions are present: in damp
locations or while wearing wet clothing; on metal structures such
as floors, gratings, or scaffolds; when in cramped positions such
as sitting, kneeling, or lying; or when there is a high risk of unavoidable or accidental contact with the workpiece or ground. For these
conditions, use the following equipment in order presented: 1) a
semiautomatic DC constant voltage (wire) welder, 2) a DC manual
(stick) welder, or 3) an AC welder with reduced open-circuit voltage. In most situations, use of a DC, constant voltage wire welder
is recommended. And, do not work alone!
Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
Properly install and ground this equipment according to its
Owner’s Manual and national, state, and local codes.
Always verify the supply ground − check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.
When making input connections, attach proper grounding conductor first − double-check connections.
Keep cords dry, free of oil and grease, and protected from hot metal
and sparks.
Frequently inspect input power cord for damage or bare wiring −
replace cord immediately if damaged − bare wiring can kill.
Turn off all equipment when not in use.
Do not use worn, damaged, undersized, or poorly spliced cables.
Do not drape cables over your body.
If earth grounding of the workpiece is required, ground it directly
with a separate cable.
Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
Do not touch electrode holders connected to two welding machines at the same time since double open-circuit voltage will be
present.
Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
Wear a safety harness if working above floor level.
Keep all panels and covers securely in place.
Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
Do not connect more than one electrode or work cable to any
single weld output terminal.
SIGNIFICANT DC VOLTAGE exists in inverter welding power sources AFTER removal of inputpower.
Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section
before touching any parts.
HOT PARTS can burn.
Do not touch hot parts bare handed.
Allow cooling period before working on equipment.
To handle hot parts, use proper tools and/or
wear heavy, insulated welding gloves and
clothing to prevent burns.
OM-222 Page 1
FUMES AND GASES can be hazardous.
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.
Keep your head out of the fumes. Do not breathe the fumes.
If inside, ventilate the area and/or use local forced ventilation at the
arc to remove welding fumes and gases.
If ventilation is poor, wear an approved air-supplied respirator.
Read and understand the Material Safety Data Sheets (MSDSs)
and the manufacturer’s instructions for metals, consumables,
coatings, cleaners, and degreasers.
Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watchperson nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breathing air is safe.
Do not weld in locations near degreasing, cleaning, or spraying operations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.
Do not weld on coated metals, such as galvanized, lead, or
cadmium plated steel, unless the coating is removed from the weld
area, the area is well ventilated, and while wearing an air-supplied
respirator. The coatings and any metals containing these elements
can give off toxic fumes if welded.
Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
Wear oil-free protective garments such as leather gloves, heavy
shirt, cuffless trousers, high shoes, and a cap.
Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
After completion of work, inspect area to ensure it is free of sparks,
glowing embers, and flames.
Use only correct fuses or circuit breakers. Do not oversize or bypass them.
Follow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B
for hot work and have a fire watcher and extinguisher nearby.
FLYING METAL or DIRT can injure eyes.
Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool,
they can throw off slag.
Wear approved safety glasses with side
shields even under your welding helmet.
BUILDUP OF GAS can injure or kill.
Shut off shielding gas supply when not in use.
Always ventilate confined spaces or use
approved air-supplied respirator.
ARC RAYS can burn eyes and skin.
Arc rays from the welding process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin. Sparks fly off from the
weld.
Wear an approved welding helmet fitted with a proper shade of
filter lenses to protect your face and eyes from arc rays and
sparks when welding or watching (see ANSI Z49.1 and Z87.1
listed in Safety Standards).
Wear approved safety glasses with side shields under your
helmet.
Use protective screens or barriers to protect others from flash,
glare and sparks; warn others not to watch the arc.
Wear protective clothing made from durable, flame-resistant
material (leather, heavy cotton, or wool) and foot protection.
WELDING can cause fire or explosion.
Welding on closed containers, such as tanks,
drums, or pipes, can cause them to blow up. Sparks
can fly off from the welding arc. The flying sparks, hot
workpiece, and hot equipment can cause fires and
burns. Accidental contact of electrode to metal objects can cause
sparks, explosion, overheating, or fire. Check and be sure the area is
safe before doing any welding.
Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
Do not weld where flying sparks can strike flammable material.
Protect yourself and others from flying sparks and hot metal.
Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
Watch for fire, and keep a fire extinguisher nearby.
Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
Do not weld on closed containers such as tanks, drums, or pipes,
unless they are properly prepared according to AWS F4.1 (see
Safety Standards).
Do not weld where the atmosphere may contain flammable dust,
gas, or liquid vapors (such as gasoline).
Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly
unknown paths and causing electric shock, sparks, and fire
hazards.
Do not use welder to thaw frozen pipes.
OM-222 Page 2
ELECTRIC AND MAGNETIC FIELDS (EMF)
can affect ImplantedMedical Devices.
Wearers of Pacemakers and other Implanted
Medical Devices should keep away.
Implanted Medical Device wearers should consult their doctor
and the device manufacturer before going near arc welding, spot
welding, gouging, plasma arc cutting, or induction heating
operations.
NOISE can damage hearing.
Noise from some processes or equipment can
damage hearing.
Wear approved ear protection if noise level is
high.
CYLINDERS can explode if damaged.
Shielding gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
Protect compressed gas cylinders from excessive heat, mechanical shocks, physical damage, slag, open flames, sparks, and arcs.
Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
Keep cylinders away from any welding or other electrical circuits.
Never drape a welding torch over a gas cylinder.
Never allow a welding electrode to touch any cylinder.
Never weld on a pressurized cylinder − explosion will result.
Use only correct shielding gas cylinders, regulators, hoses, and fittings designed for the specific application; maintain them and
associated parts in good condition.
Turn face away from valve outlet when opening cylinder valve.
Keep protective cap in place over valve except when cylinder is in
use or connected for use.
Use the right equipment, correct procedures, and sufficient number of persons to lift and move cylinders.
Read and follow instructions on compressed gas cylinders,
associated equipment, and Compressed Gas Association (CGA)
publication P-1 listed in Safety Standards.
1-3. Additional Symbols For Installation, Operation, And Maintenance
FIRE OR EXPLOSION hazard.
Do not install or place unit on, over, or near
combustible surfaces.
Do not install unit near flammables.
Do not overload building wiring − be sure power supply system is
properly sized, rated, and protected to handle this unit.
FALLING EQUIPMENT can injure.
Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
Use equipment of adequate capacity to lift and
support unit.
If using lift forks to move unit, be sure forks are long enough to
extend beyond opposite side of unit.
Keep equipment (cables and cords) away from moving vehicles
when working from an aerial location.
Follow the guidelines in the Applications Manual for the Revised
NIOSH Lifting Equation (Publication No. 94−110) when manually lifting heavy parts or equipment.
MOVING PARTS can injure.
Keep away from moving parts such as fans.
Keep all doors, panels, covers, and guards
closed and securely in place.
Have only qualified persons remove doors, panels, covers, or
guards for maintenance and troubleshooting as necessary.
Reinstall doors, panels, covers, or guards when maintenance is
finished and before reconnecting input power.
READ INSTRUCTIONS.
Read and follow all labels and the Owner’s
Manual carefully before installing, operating, or
servicing unit. Read the safety information at
the beginning of the manual and in each
section.
Use only genuine replacement parts from the manufacturer.
Perform maintenance and service according to the Owner’s
Manuals, industry standards, and national, state, and local
codes.
OVERUSE can cause OVERHEATING
H.F. RADIATION can cause interference.
Allow cooling period; follow rated duty cycle.
Reduce current or reduce duty cycle before
starting to weld again.
Do not block or filter airflow to unit.
FLYING SPARKS can injure.
Wear a face shield to protect eyes and face.
Shape tungsten electrode only on grinder with
proper guards in a safe location wearing proper
face, hand, and body protection.
Sparks can cause fires — keep flammables away.
STATIC (ESD) can damage PC boards.
Put on grounded wrist strap BEFORE handling
boards or parts.
Use proper static-proof bags and boxes to
store, move, or ship PC boards.
ARC WELDING can cause interference.
MOVING PARTS can injure.
Keep away from moving parts.
Keep away from pinch points such as drive
rolls.
WELDING WIRE can injure.
Do not press gun trigger until instructed to do
so.
Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.
High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communications equipment.
Have only qualified persons familiar with
electronic equipment perform this installation.
The user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation.
If notified by the FCC about interference, stop using the
equipment at once.
Have the installation regularly checked and maintained.
Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
Be sure all equipment in the welding area is
electromagnetically compatible.
To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
Locate welding operation 100 meters from any sensitive electronic equipment.
Be sure this welding machine is installed and grounded
according to this manual.
If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.
OM-222 Page 3
1-4. California Proposition 65 Warnings
Welding or cutting equipment produces fumes or gases
which contain chemicals known to the State of California to
cause birth defects and, in some cases, cancer. (California
Health & Safety Code Section 25249.5 et seq.)
Battery posts, terminals and related accessories contain lead
and lead compounds, chemicals known to the State of
California to cause cancer and birth defects or other
reproductive harm. Wash hands after handling.
For Gasoline Engines:
Engine exhaust contains chemicals known to the State of
California to cause cancer, birth defects, or other reproductive harm.
For Diesel Engines:
Diesel engine exhaust and some of its constituents are
known to the State of California to cause cancer, birth
defects, and other reproductive harm.
1-5. Principal Safety Standards
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
from Global Engineering Documents (phone: 1-877-413-5184, website:
www.global.ihs.com).
Safe Practices for the Preparation of Containers and Piping for Welding
and Cutting, American Welding Society Standard AWS F4.1, from Global Engineering Documents (phone: 1-877-413-5184, website:
www.global.ihs.com).
National Electrical Code, NFPA Standard 70, from National Fire Protection Association, Quincy, MA 02269 (phone: 1-800-344-3555, website:
www.nfpa.org and www. sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 4221 Walney Road, 5th Floor,
Chantilly, VA 20151 (phone: 703-788-2700, website:www.cganet.com).
Safety in Welding, Cutting, and Allied Processes, CSA Standard
W117.2, from Canadian Standards Association, Standards Sales, 5060
Spectrum Way, Suite 100, Ontario, Canada L4W 5NS (phone:
800-463-6727, website: www.csa-international.org).
Safe Practice For Occupational And Educational Eye And Face Protection, ANSI Standard Z87.1, from American National Standards Institute,
25 West 43rd Street, New York, NY 10036 (phone: 212-642-4900, website: www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, from National Fire Protection Association,
Quincy, MA 02269 (phone: 1-800-344-3555, website: www.nfpa.org.
OSHA, Occupational Safety and Health Standards for General Industry, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,
and Part 1926, Subpart J, from U.S. Government Printing Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954
(phone: 1-866-512-1800) (there are 10 OSHA Regional Offices—
phone for Region 5, Chicago, is 312-353-2220, website:
www.osha.gov).
U.S. Consumer Product Safety Commission (CPSC), 4330 East West
Highway, Bethesda, MD 20814 (phone: 301-504-7923, website:
www.cpsc.gov).
Applications Manual for the Revised NIOSH Lifting Equation, The National Institute for Occupational Safety and Health (NIOSH), 1600
Clifton Rd, Atlanta, GA 30333 (phone: 1-800-232-4636, website:
www.cdc.gov/NIOSH).
1-6. EMF Information
Electric current flowing through any conductor causes localized electric
and magnetic fields (EMF). Welding current creates an EMF field
around the welding circuit and welding equipment. EMF fields may interfere with some medical implants, e.g. pacemakers. Protective
measures for persons wearing medical implants have to be taken. For
example, access restrictions for passers−by or individual risk assessment for welders. All welders should use the following procedures in
order to minimize exposure to EMF fields from the welding circuit:
1. Keep cables close together by twisting or taping them, or using a
cable cover.
2. Do not place your body between welding cables. Arrange cables
to one side and away from the operator.
3. Do not coil or drape cables around your body.
OM-222 Page 4
4. Keep head and trunk as far away from the equipment in the
welding circuit as possible.
5. Connect work clamp to workpiece as close to the weld as
possible.
6. Do not work next to, sit or lean on the welding power source.
7. Do not weld whilst carrying the welding power source or wire
feeder.
About Implanted Medical Devices:
Implanted Medical Device wearers should consult their doctor and the
device manufacturer before performing or going near arc welding, spot
welding, gouging, plasma arc cutting, or induction heating operations.
If cleared by your doctor, then following the above procedures is recommended.
SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION
fre_som_2009−08
7
Se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes.
2-1. Symboles utilisés
DANGER! − Indique une situation dangereuse qui si on
l’évite pas peut donner la mort ou des blessures graves.
Les dangers possibles sont montrés par les symboles
joints ou sont expliqués dans le texte.
Indique une situation dangereuse qui si on l’évite pas
peut donner la mort ou des blessures graves. Les dangers possibles sont montrés par les symboles joints ou
sont expliqués dans le texte.
NOTE − Indique des déclarations pas en relation avec des blessures
personnelles.
Indique des instructions spécifiques.
Ce groupe de symboles veut dire Avertissement! Attention! DANGER
DE CHOC ELECTRIQUE, PIECES EN MOUVEMENT, et PIECES
CHAUDES. Consulter les symboles et les instructions ci-dessous y
afférant pour les actions nécessaires afin d’éviter le danger.
2-2. Dangers relatifs au soudage à l’arc
Les symboles représentés ci-dessous sont utilisés dans ce manuel pour attirer l’attention et identifier les dangers possibles. En
présence de l’un de ces symboles, prendre garde et suivre les
instructions afférentes pour éviter tout risque. Les instructions
en matière de sécurité indiquées ci-dessous ne constituent
qu’un sommaire des instructions de sécurité plus complètes
fournies dans les normes de sécurité énumérées dans la Section 2-5. Lire et observer toutes les normes de sécurité.
Seul un personnel qualifié est autorisé à installer, faire fonctionner, entretenir et réparer cet appareil.
Pendant le fonctionnement, maintenir à distance toutes les
personnes, notamment les enfants de l’appareil.
UNE DÉCHARGE ÉLECTRIQUE peut
entraîner la mort.
Le contact d’organes électriques sous tension peut
provoquer des accidents mortels ou des brûlures
graves. Le circuit de l’électrode et de la pièce est
sous tension lorsque le courant est délivré à la
sortie. Le circuit d’alimentation et les circuits internes de la machine sont également sous tension
lorsque l’alimentation est sur Marche. Dans le mode
de soudage avec du fil, le fil, le dérouleur, le bloc de
commande du rouleau et toutes les parties métalliques en contact avec le fil sont sous tension
électrique. Un équipement installé ou mis à la terre
de manière incorrecte ou impropre constitue un
danger.
Ne pas toucher aux pièces électriques sous tension.
Porter des gants isolants et des vêtements de protection secs et
sans trous.
S’isoler de la pièce à couper et du sol en utilisant des housses ou
des tapis assez grands afin d’éviter tout contact physique avec la
pièce à couper ou le sol.
Ne pas se servir de source électrique à courant électrique dans les
zones humides, dans les endroits confinés ou là où on risque de
tomber.
Se servir d’une source électrique à courant électrique UNIQUEMENT si le procédé de soudage le demande.
Si l’utilisation d’une source électrique à courant électrique s’avère
nécessaire, se servir de la fonction de télécommande si l’appareil
en est équipé.
D’autres consignes de sécurité sont nécessaires dans les conditions suivantes : risques électriques dans un environnement
humide ou si l’on porte des vêtements mouillés ; sur des structures
métalliques telles que sols, grilles ou échafaudages ; en position
coincée comme assise, à genoux ou couchée ; ou s’il y a un risque
élevé de contact inévitable ou accidentel avec la pièce à souder ou
le sol. Dans ces conditions, utiliser les équipements suivants,
dans l’ordre indiqué : 1) un poste à souder DC à tension constante
(à fil), 2) un poste à souder DC manuel (électrode) ou 3) un poste à
souder AC à tension à vide réduite. Dans la plupart des situations,
l’utilisation d’un poste à souder DC à fil à tension constante est recommandée. En outre, ne pas travailler seul !
Couper l’alimentation ou arrêter le moteur avant de procéder à l’installation, à la réparation ou à l’entretien de l’appareil. Déverrouiller
l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de sécurité).
Installer le poste correctement et le mettre à la terre convenablement selon les consignes du manuel de l’opérateur et les normes
nationales, provinciales et locales.
Toujours vérifier la terre du cordon d’alimentation. Vérifier et
s’assurer que le fil de terre du cordon d’alimentation est bien
raccordé à la borne de terre du sectionneur ou que la fiche du
cordon est raccordée à une prise correctement mise à la terre.
En effectuant les raccordements d’entrée, fixer d’abord le conducteur de mise à la terre approprié et contre-vérifier les connexions.
Les câbles doivent être exempts d’humidité, d’huile et de graisse;
protégez−les contre les étincelles et les pièces métalliques
chaudes.
Vérifier fréquemment le cordon d’alimentation afin de s’assurer
qu’il n’est pas altéré ou à nu, le remplacer immédiatement s’il l’est.
Un fil à nu peut entraîner la mort.
L’équipement doit être hors tension lorsqu’il n’est pas utilisé.
Ne pas utiliser des câbles usés, endommagés, de grosseur insuffisante ou mal épissés.
Ne pas enrouler les câbles autour du corps.
Si la pièce soudée doit être mise à la terre, le faire directement
avec un câble distinct.
Ne pas toucher l’électrode quand on est en contact avec la pièce,
la terre ou une électrode provenant d’une autre machine.
Ne pas toucher des porte électrodes connectés à deux machines
en même temps à cause de la présence d’une tension à vide doublée.
N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-lechamp les pièces endommagées. Entretenir l’appareil conformément à ce manuel.
Porter un harnais de sécurité si l’on doit travailler au-dessus du sol.
S’assurer que tous les panneaux et couvercles sont correctement
en place.
Fixer le câble de retour de façon à obtenir un bon contact métalmétal avec la pièce à souder ou la table de travail, le plus près possible de la soudure.
Isoler la pince de masse quand pas mis à la pièce pour éviter le
contact avec tout objet métallique.
Ne pas raccorder plus d’une électrode ou plus d’un câble de
masse à une même borne de sortie de soudage.
OM-222 Page 5
Il reste une TENSION DC NON NÉGLIGEABLE dans
les sources de soudage onduleur UNE FOIS
l’alimentation coupée.
Arrêter les convertisseurs, débrancher le courant électrique et
décharger les condensateurs d’alimentation selon les instructions
indiquées dans la partie Entretien avant de toucher les pièces.
LES PIÈCES CHAUDES peuvent
provoquer des brûlures.
Ne pas toucher à mains nues les parties
chaudes.
Prévoir une période de refroidissement avant de
travailler à l’équipement.
Ne pas toucher aux pièces chaudes, utiliser les outils recommandés et porter des gants de soudage et des vêtements épais pour
éviter les brûlures.
LES FUMÉES ET LES GAZ peuvent
être dangereux.
Le soudage génère des fumées et des gaz. Leur
inhalation peut être dangereux pour votre santé.
Eloigner votre tête des fumées. Ne pas respirer les fumées.
À l’intérieur, ventiler la zone et/ou utiliser une ventilation forcée au
niveau de l’arc pour l’évacuation des fumées et des gaz de
soudage.
Si la ventilation est médiocre, porter un respirateur anti-vapeurs
approuvé.
Porter des vêtements confectionnés avec des matières résistantes et ignifuges (cuir, coton lourd ou laine) et des bottes de
protection.
LE SOUDAGE peut provoquer un
incendie ou une explosion.
Le soudage effectué sur des conteneurs fermés tels
que des réservoirs, tambours ou des conduites peut
provoquer leur éclatement. Des étincelles peuvent
être projetées de l’arc de soudure. La projection d’étincelles, des
pièces chaudes et des équipements chauds peut provoquer des
incendies et des brûlures. Le contact accidentel de l’électrode avec
des objets métalliques peut provoquer des étincelles, une explosion,
un surchauffement ou un incendie. Avant de commencer le soudage,
vérifier et s’assurer que l’endroit ne présente pas de danger.
Déplacer toutes les substances inflammables à une distance de
10,7 m de l’arc de soudage. En cas d’impossibilité les recouvrir
soigneusement avec des protections homologués.
Ne pas souder dans un endroit là où des étincelles peuvent tomber
sur des substances inflammables.
Se protéger et d’autres personnes de la projection d’étincelles et
de métal chaud.
Des étincelles et des matériaux chauds du soudage peuvent
facilement passer dans d’autres zones en traversant de petites
fissures et des ouvertures.
Surveiller tout déclenchement d’incendie et tenir un extincteur à
proximité.
Le soudage effectué sur un plafond, plancher, paroi ou séparation
peut déclencher un incendie de l’autre côté.
Ne pas effectuer le soudage sur des conteneurs fermés tels que
des réservoirs, tambours, ou conduites, à moins qu’ils n’aient été
préparés correctement conformément à AWS F4.1 (voir les normes de sécurité).
Lire et comprendre les spécifications de sécurité des matériaux
(MSDS) et les instructions du fabricant concernant les métaux, les
consommables, les revêtements, les nettoyants et les dégraisseurs.
Ne soudez pas si l’air ambiant est chargé de particules, gaz, ou vapeurs inflammables (vapeur d’essence, par exemple).
Travailler dans un espace fermé seulement s’il est bien ventilé ou
en portant un respirateur à alimentation d’air. Demander toujours à
un surveillant dûment formé de se tenir à proximité. Des fumées et
des gaz de soudage peuvent déplacer l’air et abaisser le niveau
d’oxygène provoquant des blessures ou des accidents mortels.
S’assurer que l’air de respiration ne présente aucun danger.
Ne pas utiliser le poste de soudage pour dégeler des conduites gelées.
Ne pas souder dans des endroits situés à proximité d’opérations
de dégraissage, de nettoyage ou de pulvérisation. La chaleur et
les rayons de l’arc peuvent réagir en présence de vapeurs et former des gaz hautement toxiques et irritants.
Ne pas souder des métaux munis d’un revêtement, tels que l’acier
galvanisé, plaqué en plomb ou au cadmium à moins que le revêtement n’ait été enlevé dans la zone de soudure, que l’endroit soit
bien ventilé, et en portant un respirateur à alimentation d’air. Les
revêtements et tous les métaux renfermant ces éléments peuvent
dégager des fumées toxiques en cas de soudage.
LES RAYONS DE L’ARC peuvent
provoquer des brûlures dans les
yeux et sur la peau.
Le rayonnement de l’arc du procédé de soudage
génère des rayons visibles et invisibles intense
(ultraviolets et infrarouges) susceptibles de provoquer des brûlure
dans les yeux et sur la peau. Des étincelles sont projetées pendant le
soudage.
Porter un casque de soudage approuvé muni de verres filtrants
approprié pour protéger visage et yeux pour protéger votre visage
et vos yeux pendant le soudage ou pour regarder (voir ANSI Z49.1
et Z87.1 énuméré dans les normes de sécurité).
Porter des lunettes de sécurité avec écrans latéraux même sous
votre casque.
Avoir recours à des écrans protecteurs ou à des rideaux pour
protéger les autres contre les rayonnements les éblouissements
et les étincelles ; prévenir toute personne sur les lieux de ne pas
regarder l’arc.
OM-222 Page 6
Brancher le câble de masse sur la pièce le plus près possible de la
zone de soudage pour éviter le transport du courant sur une
longue distance par des chemins inconnus éventuels en provoquant des risques d’électrocution, d’étincelles et d’incendie.
En cas de non utilisation, enlever la baguette d’électrode du porteélectrode ou couper le fil à la pointe de contact.
Porter des vêtements de protection dépourvus d’huile tels que des
gants en cuir, une chemise en matériau lourd, des pantalons sans
revers, des chaussures hautes et un couvre chef.
Avant de souder, retirer toute substance combustible de vos poches telles qu’un allumeur au butane ou des allumettes.
Une fois le travail achevé, assurez−vous qu’il ne reste aucune
trace d’étincelles incandescentes ni de flammes.
Utiliser exclusivement des fusibles ou coupe−circuits appropriés.
Ne pas augmenter leur puissance; ne pas les ponter.
Une fois le travail achevé, assurez−vous qu’il ne reste aucune
trace d’étincelles incandescentes ni de flammes.
Utiliser exclusivement des fusibles ou coupe−circuits appropriés.
Ne pas augmenter leur puissance; ne pas les ponter.
Suivre les recommandations dans OSHA 1910.252(a)(2)(iv) et
NFPA 51B pour les travaux à chaud et avoir de la surveillance et un
extincteur à proximité.
DES PIECES DE METAL ou DES
SALETES peuvent provoquer des
blessures dans les yeux.
Le soudage, l’écaillement, le passage de la pièce à la brosse en
fil de fer, et le meulage génèrent des étincelles et des particules
métalliques volantes. Pendant la période de refroidissement des
soudures, elles risquent de projeter du laitier.
Porter des lunettes de sécurité avec écrans latéraux ou un écran
facial.
LES ACCUMULATIONS DE GAZ
risquent de provoquer des blessures
ou même la mort.
Fermer l’alimentation du gaz protecteur en cas
de non-utilisation.
Veiller toujours à bien aérer les espaces confinés ou se servir d’un respirateur d’adduction
d’air homologué.
Les CHAMPS ÉLECTROMAGNÉTIQUES (CEM)
peuvent affecter les implants médicaux.
Les porteurs de stimulateurs cardiaques
et autres implants médicaux doivent rester
à distance.
Les porteurs d’implants médicaux doivent consulter
leur médecin et le fabricant du dispositif avant de s’approcher
de la zone où se déroule du soudage à l’arc, du soudage
par points, du gougeage, de la découpe plasma
ou une opération de chauffage par induction.
LES BOUTEILLES peuvent exploser
si elles sont endommagées.
Des bouteilles de gaz protecteur contiennent du gaz
sous haute pression. Si une bouteille est endommagée, elle peut exploser. Du fait que les bouteilles
de gaz font normalement partie du procédé de
soudage, les manipuler avec précaution.
Protéger les bouteilles de gaz comprimé d’une chaleur excessive,
des chocs mécaniques, des dommages physiques, du laitier, des
flammes ouvertes, des étincelles et des arcs.
Placer les bouteilles debout en les fixant dans un support stationnaire ou dans un porte-bouteilles pour les empêcher de tomber ou
de se renverser.
Tenir les bouteilles éloignées des circuits de soudage ou autres
circuits électriques.
Ne jamais placer une torche de soudage sur une bouteille à gaz.
Une électrode de soudage ne doit jamais entrer en contact avec
une bouteille.
Ne jamais souder une bouteille pressurisée − risque d’explosion.
Utiliser seulement des bouteilles de gaz protecteur, régulateurs,
tuyaux et raccords convenables pour cette application spécifique ;
les maintenir ainsi que les éléments associés en bon état.
Détourner votre visage du détendeur-régulateur lorsque vous
ouvrez la soupape de la bouteille.
LE BRUIT peut endommager l’ouïe.
Le bruit des processus et des équipements peut
affecter l’ouïe.
Porter des protections approuvées pour les
oreilles si le niveau sonore est trop élevé.
Le couvercle du détendeur doit toujours être en place, sauf lorsque
la bouteille est utilisée ou qu’elle est reliée pour usage ultérieur.
Utiliser les équipements corrects, les bonnes procédures et suffisamment de personnes pour soulever et déplacer les bouteilles.
Lire et suivre les instructions sur les bouteilles de gaz comprimé,
l’équipement connexe et le dépliant P-1 de la CGA (Compressed
Gas Association) mentionné dans les principales normes de sécurité.
2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance
Risque D’INCENDIE OU
D’EXPLOSION.
Ne pas placer l’appareil sur, au-dessus ou
à proximité de surfaces inflammables.
Ne pas installer l’appareil à proximité de produits inflammables.
Ne pas surcharger l’installation électrique − s’assurer que
l’alimentation est correctement dimensionnée et protégée avant
de mettre l’appareil en service.
LA CHUTE DE L’ÉQUIPEMENT peut
provoquer des blessures.
Utiliser l’anneau de levage uniquement pour
soulever l’appareil, NON PAS les chariots, les
bouteilles de gaz ou tout autre accessoire.
Utiliser un équipement de levage de capacité
suffisante pour lever l’appareil.
En utilisant des fourches de levage pour déplacer l’unité, s’assurer que les fourches sont suffisamment longues pour dépasser
du côté opposé de l’appareil.
Tenir l’équipement (câbles et cordons) à distance des véhicules
mobiles lors de toute opération en hauteur.
Suivre les consignes du Manuel des applications pour l’équation
de levage NIOSH révisée (Publication Nº94–110) lors du levage
manuelle de pièces ou équipements lourds.
L’EMPLOI
EXCESSIF
peut
SURCHAUFFER L’ÉQUIPEMENT.
Prévoir une période de refroidissement ; respecter le cycle opératoire nominal.
Réduire le courant ou le facteur de marche
avant de poursuivre le soudage.
Ne pas obstruer les passages d’air du poste.
LES ÉTINCELLES PROJETÉES
peuvent provoquer des blessures.
Porter un écran facial pour protéger le visage et
les yeux.
Affûter l’électrode au tungstène uniquement à la
meuleuse dotée de protecteurs. Cette
manœuvre est à exécuter dans un endroit sûr
lorsque l’on porte l’équipement homologué de
protection du visage, des mains et du corps.
Les étincelles risquent de causer un incendie − éloigner toute substance inflammable.
LES CHARGES ÉLECTROSTATIQUES peuvent endommager les circuits imprimés.
Établir la connexion avec la barrette de terre
avant de manipuler des cartes ou des pièces.
Utiliser des pochettes et des boîtes antistatiques pour stocker, déplacer ou expédier des
cartes de circuits imprimes.
OM-222 Page 7
Les PIÈCES MOBILES peuvent
causer des blessures.
LE
RAYONNEMENT
HAUTE
FRÉQUENCE
(H.F.)
risque
de
provoquer des interférences.
Ne pas s’approcher des organes mobiles.
Ne pas s’approcher des points de coincement
tels que des rouleaux de commande.
LES FILS DE SOUDAGE peuvent
provoquer des blessures.
Ne pas appuyer sur la gâchette avant d’en
avoir reçu l’instruction.
Ne pas diriger le pistolet vers soi, d’autres
personnes ou toute pièce mécanique en
engageant le fil de soudage.
Les PIÈCES MOBILES peuvent
causer des blessures.
S’abstenir de toucher des organes mobiles tels
que des ventilateurs.
Maintenir fermés et verrouillés les portes,
panneaux, recouvrements et dispositifs de
protection.
Lorsque cela est nécessaire pour des travaux d’entretien et de
dépannage, faire retirer les portes, panneaux, recouvrements
ou dispositifs de protection uniquement par du personnel qualifié.
Remettre les portes, panneaux, recouvrements ou dispositifs de
protection quand l’entretien est terminé et avant de rebrancher
l’alimentation électrique.
LIRE LES INSTRUCTIONS.
Lire et appliquer les instructions sur les
étiquettes et le Mode d’emploi avant l’installation, l’utilisation ou l’entretien de l’appareil.
Lire les informations de sécurité au début du
manuel et dans chaque section.
N’utiliser que les pièces de rechange recommandées par le
constructeur.
Effectuer l’entretien en respectant les manuels d’utilisation, les
normes industrielles et les codes nationaux, d’état et locaux.
Le rayonnement haute fréquence (H.F.) peut
provoquer des interférences avec les équipements de radio−navigation et de communication, les services de sécurité et les ordinateurs.
Demander seulement à des personnes qualifiées familiarisées
avec des équipements électroniques de faire fonctionner l’installation.
L’utilisateur est tenu de faire corriger rapidement par un électricien
qualifié les interférences résultant de l’installation.
Si le FCC signale des interférences, arrêter immédiatement l’appareil.
Effectuer régulièrement le contrôle et l’entretien de l’installation.
Maintenir soigneusement fermés les portes et les panneaux des
sources de haute fréquence, maintenir les éclateurs à une distance correcte et utiliser une terre et un blindage pour réduire les
interférences éventuelles.
LE SOUDAGE À L’ARC risque de
provoquer des interférences.
L’énergie électromagnétique risque de
provoquer des interférences pour l’équipement
électronique sensible tel que les ordinateurs et
l’équipement commandé par ordinateur tel que
les robots.
Veiller à ce que tout l’équipement de la zone de soudage soit
compatible électromagnétiquement.
Pour réduire la possibilité d’interférence, maintenir les câbles de
soudage aussi courts que possible, les grouper, et les poser
aussi bas que possible (ex. par terre).
Veiller à souder à une distance de 100 mètres de tout équipement électronique sensible.
Veiller à ce que ce poste de soudage soit posé et mis à la terre
conformément à ce mode d’emploi.
En cas d’interférences après avoir pris les mesures précédentes, il incombe à l’utilisateur de prendre des mesures supplémentaires telles que le déplacement du poste, l’utilisation de câbles blindés, l’utilisation de filtres de ligne ou la pose de protecteurs dans la zone de travail.
2-4. Proposition californienne 65 Avertissements
Les équipements de soudage et de coupage produisent des
fumées et des gaz qui contiennent des produits chimiques
dont l’État de Californie reconnaît qu’ils provoquent des malformations congénitales et, dans certains cas, des cancers.
(Code de santé et de sécurité de Californie, chapitre 25249.5
et suivants)
Les batteries, les bornes et autres accessoires contiennent
du plomb et des composés à base de plomb, produits chimiques dont l’État de Californie reconnaît qu’ils provoquent des
cancers et des malformations congénitales ou autres
problèmes de procréation. Se laver les mains après manipulation.
OM-222 Page 8
Pour les moteurs à essence :
Les gaz d’échappement des moteurs contiennent des produits chimiques dont l’État de Californie reconnaît qu’ils
provoquent des cancers et des malformations congénitales
ou autres problèmes de procréation.
Pour les moteurs diesel :
Les gaz d’échappement des moteurs diesel et certains de
leurs composants sont reconnus par l’État de Californie comme provoquant des cancers et des malformations
congénitales ou autres problèmes de procréation.
2-5. Principales normes de sécurité
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
de Global Engineering Documents (téléphone : 1-877-413-5184, site
Internet : www.global.ihs.com).
Safe Practices for the Preparation of Containers and Piping for Welding
and Cutting, American Welding Society Standard AWS F4.1, de Global
Engineering Documents (téléphone : 1-877-413-5184, site internet :
www.global.ihs.com).
National Electrical Code, NFPA Standard 70, de National Fire Protection Association, Quincy, MA 02269 (téléphone : 800-344-3555, site
Internet : www.nfpa.org et www.sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
de Compressed Gas Association, 4221 Walney Road, 5th Floor, Chantilly, VA 20151 (téléphone : 703-788-2700, site Internet :
www.cganet.com).
Safety in Welding, Cutting, and Allied Processes, CSA Standard
W117.2, de Canadian Standards Association, Standards Sales, 5060
Spectrum Way, Suite 100, Ontario, Canada L4W 5NS (téléphone :
800-463-6727, site internet : www.csa-international.org).
Safe Practice For Occupational And Educational Eye And Face Protection, ANSI Standard Z87.1, de American National Standards Institute,
25 West 43rd Street, New York, NY 10036 (téléphone : 212-642-4900,
site Internet : www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, de National Fire Protection Association,
P.O. Box 9101, Quincy, MA 02269-9101 (téléphone : 617-770-3000,
site Internet : www.nfpa.org).
OSHA, Occupational Safety and Health Standards for General
Industry, Title 29, Code of Federal Regulations (CFR), Part 1910,
Subpart Q, and Part 1926, Subpart J, de U.S. Government Printing
Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA
15250-7954 (téléphone : 1-866-512-1800) (il y a 10 bureaux
régionaux−le téléphone de la région 5, Chicago, est 312-353-2220, site
Internet : www.osha.gov).
U.S. Consumer Product Safety Commission (CPSC), 4330 East West
Highway, Bethesda, MD 20814 (téléphone : 301-504-7923, site internet : www.cpsc.gov).
Applications Manual for the Revised NIOSH Lifting Equation, The
National Institute for Occupational Safety and Health (NIOSH), 1600
Clifton Rd, Atlanta, GA 30333 (télé[hone : 1-800-232-4636, site internet:
www.cdc.gov/NIOSH).
2-6. Informations relatives aux CEM
Le courant électrique qui traverse tout conducteur génère des champs
électromagnétiques (CEM) à certains endroits. Le courant de soudage
crée un CEM autour du circuit et du matériel de soudage. Les CEM
peuvent créer des interférences avec certains implants médicaux
comme des stimulateurs cardiaques. Des mesures de protection pour
les porteurs d’implants médicaux doivent être prises: par exemple, des
restrictions d’accès pour les passants ou une évaluation individuelle
des risques pour les soudeurs. Tous les soudeurs doivent appliquer les
procédures suivantes pour minimiser l’exposition aux CEM provenant
du circuit de soudage:
4
Maintenir la tête et le torse aussi loin que possible du matériel du
circuit de soudage.
5
Connecter la pince sur la pièce aussi près que possible de la
soudure.
6
Ne pas travailler à proximité d’une source de soudage, ni
s’asseoir ou se pencher dessus.
7
Ne pas souder tout en portant la source de soudage ou le
dévidoir.
1
En ce qui concerne les implants médicaux :
2
3
Rassembler les câbles en les torsadant ou en les attachant avec
du ruban adhésif ou avec une housse.
Ne pas se tenir au milieu des câbles de soudage. Disposer les
câbles d’un côté et à distance de l’opérateur.
Ne pas courber et ne pas entourer les câbles autour de votre
corps.
Les porteurs d’implants doivent d’abord consulter leur médecin avant
de s’approcher des opérations de soudage à l’arc, de soudage par
points, de gougeage, du coupage plasma ou de chauffage par induction. Si le médecin approuve, il est recommandé de suivre les
procédures précédentes.
OM-222 Page 9
OM-222 Page 10
SECTION 3 − DEFINITIONS
3-1. General Precautionary Label
Warning! Watch Out! There are
possible hazards as shown by the
symbols.
1
1.1
1.2
1.3
2
2.1
2.2
2.3
3
3.1
3.2
3.3
4
4.1
5
6
Electric shock from welding
electrode or wiring can kill.
Wear dry insulating gloves.
Do not touch electrode with
bare hand. Do not wear wet or
damaged gloves.
Protect yourself from electric
shock by insulating yourself
from work and ground.
Disconnect input plug or
power before working on
machine.
Breathing welding fumes can
be hazardous to your health.
Keep your head out of the
fumes.
Use forced ventilation or local
exhaust to remove the fumes.
Use ventilating fan to remove
fumes.
Welding sparks can cause
explosion or fire.
Keep flammables away from
welding. Do not weld near
flammables.
Welding sparks can cause
fires. Have a fire extinguisher
nearby, and have a
watchperson ready to use it.
Do not weld on drums or any
closed containers.
Arc rays can burn eyes and
injure skin.
Wear hat and safety glasses.
Use ear protection and button
shirt collar. Use welding
helmet with correct shade of
filter. Wear complete body
protection.
Become trained and read the
instructions before working on
the machine or welding.
Do not remove or paint over
(cover) the label.
OM-222 Page 11
3-2. Input Connection Label
1
2
3
4
1
Warning! Watch Out! There
are possible hazards as
shown by the symbols.
Electric shock from wiring can
kill.
Disconnect input plug or
power before working on
machine.
Read the Owner’s Manual
before working on this
machine.
Consult rating label for input
power requirements, and
check power available at the
job site − they must match.
Read Owner’s Manual and
inside labels for connection
points and procedures.
Move jumper links as shown
on inside label to match
voltage at job site.
Having a loop of extra length,
connect grounding conductor
first.
Connect line input conductors
as shown on inside label −
double-check all connections,
jumper link positions, and
input voltage before applying
power.
2
3
4
1
2
?
V
?
A
3
?
5
V
6
ÍÍÍ
ÍÍÍ
ÍÍÍ
ÍÍÍ
ÍÍÍ
5
6
7
5
3
8
4
S-179 290
7
8
9
9
1/96
3-3. Electric Shock And Airflow Label
1
2
1
3
2
3
S-179 563
Warning! Watch Out! There
are possible hazards as
shown by the symbols.
Electric shock from wiring and
exposed weld terminals can
kill.
Close door before turning on
unit.
1/96
3-4. Nameplate Safety Symbols
1
1
1
2
3
4
5
2
3
4
5
6
6
Warning! Watch Out! There
are possible hazards as
shown by the symbols.
Electric shock from welding
electrode or wiring can kill.
Sparks from arcing electrode
can cause explosion or fire −
disconnect cable for process
not in use.
Read Owner’s Manual for
connection procedures.
Electric shock from wiring can
kill.
Disconnect input power
before working on unit or
making terminal strip
connections.
Nameplate D-179 389
OM-222 Page 12
3-5. Symbols And Definitions
Some symbols are found only on CE products.
A
U0
I1
IP
Amperes
Amperage Control/
Panel
Gas Tungsten Arc
Welding (GTAW)
Shielded Metal Arc
Welding (SMAW)
Temperature
Do Not Switch
While Welding
Arc Force (DIG)
Percent
Output
Circuit Breaker
Remote
Protective Earth
(Ground)
Positive
Negative
Input
On
Off
Hertz
Direct Current
Conventional Load
Voltage
Line Connection
Duty Cycle
Three-Phase
Transformer
Rectifier
KVA
Work Connection
Rated No Load
Voltage (Average)
U1
Primary Voltage
Primary Current
I2
Rated Welding
Current
Degree Of
Protection
Three-Phase
Wire Feeder
Electrode
Connection
Hz
U2
X
S1
V
Volts
3-6. WEEE Label (For Products Sold Within The EU)
Do not discard product (where applicable) with general waste.
Reuse or recycle Waste Electrical
and Electronic Equipment (WEEE)
by disposing at a designated collection facility.
Contact your local recycling office
or your local distributor for further
information.
OM-222 Page 13
SECTION 4 − INSTALLATION
4-1. Important Information Regarding CE Products (Sold Within The EU)
!
This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding.
This equipment is built in accordance with EN 60974−1 and is intended to be used only in an occupational environment (where the general public
access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding
circuit may not be a major contributor to the EMF. See the Owner’s Manuals for all components of the welding circuit for additional EMF exposure
information.
The EMF assessment on this equipment was conducted at 0.5 meter.
At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.
4-2. Serial Number And Rating Label Location
The serial number and rating information for the power source is located on the front or the rear of the machine. Use the rating labels to determine
input power requirements and/or rated output. For future reference, write serial number in space provided on back cover of this manual.
4-3. Specifications
Model
Rated
Welding
Output
Amp
Range DC
Maximum
OpenCircuit
Voltage DC
IP
Rating
300
Amp
300 A @
32 Volts
DC, 60%
Duty Cycle
15 − 395
68
(70)
450
Amp
450 A @
38 Volts
DC, 60%
Duty Cycle
20 − 590
650
Amp
650 A @
44 Volts
DC, 60%
Duty Cycle
50 − 850
200 V
230 V
380 V
400 V
440 V
460 V
575 V
KVA
KW
21M
70
4.0*
61
3.6*
35
1.1*
33
1.1*
31
1.0*
31
3.1*
25
1.5*
24.5
1.3*
13.8
0.67*
71
(70)
21M
102
3.5*
89
3.1*
54
1.5*
51
1.4*
47
1.2*
45
1.5*
36
1.2*
35.5
1.2*
23.3
0.51*
71
(70)
21M
−−
124
5.2*
75
1.7*
71
1.6*
65
1.5*
62
2.6*
50
2.1*
49.4
2.1*
36
0.58*
*While idling
( ) Indicates specification differences for CE models
OM-222 Page 14
Amperes Input at Rated Load Output, 50 or 60 Hz,
Three-Phase
4-4. Duty Cycle And Overheating
Duty Cycle is percentage of 10 minutes that unit can weld at rated load
without overheating.
If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
duty cycle before welding.
NOTICE − Exceeding duty cycle
can damage unit and void warranty.
Example: 60% Duty Cycle =
6 Minutes Welding
Overheating
4 Minutes Resting
A
0
15
Minutes
OR
Reduce Duty Cycle
duty1 4/95 / Ref. 168 919
OM-222 Page 15
4-5. Volt-Ampere Curves
A. 300 Amp Model
Volt-ampere curves show minimum and maximum voltage and
amperage output capabilities of
unit. Curves of other settings fall between curves shown.
B. 450 Amp Model
C. 650 Amp Model
va_curve1 − 4/95 − 171 221 / 171 222 / 171 223
OM-222 Page 16
4-6. Selecting A Location
1
2
Lifting Eye
Lifting Forks
Use lifting eye or lifting forks to
move unit.
If using lifting forks, extend forks
beyond opposite side of unit.
Movement
3
Line Disconnect Device
Locate unit near correct input power supply.
!
1
Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
OR
2
Location And Airflow
3
18 in.
(460 mm)
18 in.
(460 mm)
OM-222 Page 17
4-7. Dimensions And Weights
Dimensions
300 Amp Models
450 Amp Models
650 Amp Models
A
30 in. (762 mm) including lift eye
30 in. (762 mm) including lift eye
30 in. (762 mm) including lift eye
B
23 in. (585 mm)
23 in. (585 mm)
23 in. (585 mm)
C
30-1/2 in. (775 mm) including strain relief
38 in. (966 mm) including strain relief
38 in. (966 mm) including strain relief
D
27-1/2 in. (699 mm)
35 in. (889 mm)
35 in. (889 mm)
E
3/4 in. (19 mm)
1-1/4 in. (32 mm)
1-1/4 in. (32 mm)
F
21-1/8 in. (537 mm)
21-1/8 in. (537 mm)
21-1/8 in. (537 mm)
G
1-1/8 in. (29 mm)
1-1/8 in. (29 mm)
1-1/8 in. (29 mm)
H
7/16 in. (11 mm) Dia
7/16 in. (11 mm) Dia
7/16 in. (11 mm) Dia
352 lb (160 kg)
404 lb (183 kg)
Weight
505 lb (229 kg)
F
G
H
4 Holes
A
D
B
C
E
Front
800 453-A / 801 530
OM-222 Page 18
4-8. Tipping
!
Do not move or operate unit
where it could tip.
4-9. 115 VAC Receptacle And Supplementary Protectors
3
!
Turn Off power before
connecting to receptacle.
1
115 V 15 A AC Receptacle
RC9
Power is shared between RC9 and
Remote 14 receptacle RC8 (see
Section 4-14).
2
2
3
Supplementary Protector CB1
Supplementary Protector CB2
CB1 protects the 115 volts ac portion of RC8 and RC9 from overload.
1
CB2 protects the 24 volts ac portion
of RC8.
Press button to reset protector.
Ref. 800 101-D
4-10. Weld Output Terminals
!
Turn Off power before
connecting to weld output
receptacle.
1
2
Electrode Output Terminal
Work Output Terminal
Select cables according to Section
4-11.
!
Do not use worn, damaged,
undersized,
or
poorly
spliced cables.
Connect weld cables according to
Section 4-12.
1
2
Ref. 800 101-D
OM-222 Page 19
4-11. Selecting Cable Sizes*
NOTICE − The Total Cable Length in Weld Circuit (see table below) is the combined length of both weld cables. For example, if the power source is
100 ft (30 m) from the workpiece, the total cable length in the weld circuit is 200 ft (2 cables x 100 ft). Use the 200 ft (60 m) column to determine cable
size.
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit
Not Exceeding***
Weld Output
Terminals
!
Turn off power before connecting to
weld output terminals.
!
Do not use worn,
damaged,
undersized, or poorly
spliced cables.
100 ft (30 m) or Less
200 ft
(60 m)
250 ft
(70 m)
300 ft
(90 m)
350 ft
400 ft
(105 m) (120 m)
10 − 60%
Duty
Cycle
60 − 100%
Duty
Cycle
AWG (mm2)
AWG (mm2)
100
4 (20)
4 (20)
4 (20)
3 (30)
2 (35)
1 (50)
1/0 (60)
1/0 (60)
150
3 (30)
3 (30)
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
3/0 (95)
200
3 (30)
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
4/0 (120)
250
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 2/0
(2x70)
300
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 3/0
(2x95)
350
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
400
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
2 ea. 4/0
(2x120)
500
2/0 (70)
3/0 (95)
4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
3 ea. 3/0
(3x95)
3 ea. 3/0
(3x95)
600
3/0 (95)
4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
3 ea. 3/0
(3x95)
3 ea. 4/0
(3x120)
3 ea. 4/0
(3x120)
700
4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
3 ea. 3/0
(3x95)
3 ea. 4/0
(3x120)
3 ea. 4/0
(3x120)
4 ea. 4/0
(4x120)
800
4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
3 ea. 4/0
(3x120)
3 ea. 4/0
(3x120)
4 ea. 4/0
(4x120)
4 ea. 4/0
(4x120)
Welding
Amperes
* This
150 ft
(45 m)
10 − 100% Duty Cycle
AWG (mm2)
chart is a general guideline and may not suit all applications. If cable overheats, use next size larger cable.
**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
( ) = mm2 for metric use
***For distances longer than those shown in this guide, call a factory applications rep. at 920-735-4505 (Miller) or 1-800-332-3281 (Hobart)
Ref. S-0007-G 2009−08
OM-222 Page 20
4-12. Connecting Weld Output Cables
4
1
Do not place
anything between
weld cable terminal
and copper bar.
2
Tools Needed:
3
3/4 in (19 mm)
803 778-B
Correct Installation
!
Turn off power before connecting to
weld output terminals.
!
Failure to properly connect weld
cables may cause excessive heat
and start a fire, or damage your machine.
Incorrect Installation
1 Weld Output Terminal
2 Supplied Weld Output Terminal Nut
3 Weld Cable Terminal
4 Copper Bar
Remove supplied nut from weld output terminal. Slide weld cable terminal onto weld
output terminal and secure with nut so that
weld cable terminal is tight against copper
bar. Do not place anything between weld
cable terminal and copper bar. Make
sure that the surfaces of the weld cable
terminal and copper bar are clean.
4-13. Remote 14 Receptacle Information
Socket
24 VOLTS AC
REMOTE OUTPUT CONTROL
115 VOLTS AC
GND
REMOTE POWER ON/OFF
REMOTE VOLTAGE SENSING
Information
A
24 volts AC. Protected by supplementary protector CB2.
B
Contact closure to A completes 24 volts AC contactor control circuit.
C
Command reference; 0 to +10 volts DC.
D
Remote control circuit common.
E
0 to +10 volts DC input command signal from remote control.
F
Current feedback; 1 volt per 100 amperes.
H
Voltage feedback; 1 volt per 10 arc volts.
I
115 volts, 15 amperes, 60 Hz AC. Protected by supplementary protector CB1.
J
Contact closure to I completes 115 volts AC contactor control circuit.
K
Chassis common.
G
Circuit common for 24 and 115 volts AC circuits.
*
*
To remote On/Off switch.
*
Voltage sensing signal from Negative (-) weld output terminal.
*
Voltage sensing signal from Positive (+) weld output terminal.
* Not Used
OM-222 Page 21
4-14. Connecting Remote Control
1
Remote 14 Receptacle RC8
Connect remote control to RC8.
1
A
B
K
J
I
H
C L N
D M
G
E F
OR
OR
Ref. 800 101-D / 141 127-D
OM-222 Page 22
4-15. Electrical Service Guide
Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommendations are for a dedicated branch circuit sized for the rated output and duty cycle of the welding power source.
60 Hertz Models
300 Amp Model
450 Amp Model
650 Amp Model
Input Voltage (V)
200
230
460
575
200
230
460
575
230
460
575
Input Amperes (A) At Rated Output
70
61
31
25
102
89
45
36
124
62
50
Time-Delay Fuses 2
80
70
35
30
125
110
50
45
150
70
60
Normal Operating Fuses 3
110
90
45
35
150
125
70
50
175
90
70
6
8
10
12
4
4
8
10
3
8
8
149
(45)
131
(40)
356
(108)
342
(104)
136
(41)
180
(55)
319
(97)
335
(102)
144
(44)
210
(64)
328
(100)
6
8
10
12
6
6
8
10
6
8
8
Max Recommended Standard Fuse
Rating In Amperes 1
Min Input Conductor Size In AWG 4
Max Recommended Input Conductor
Length In Feet (Meters)
Min Grounding Conductor Size In
AWG 4
Reference: 2008 National Electrical Code (NEC) (including article 630)
1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse.
2 “Time-Delay” fuses are UL class “RK5” . See UL 248.
3 “Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amps), and UL class “H” ( 65 amps and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.
Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommendations are for a dedicated branch circuit sized for the rated output and duty cycle of the welding power source.
300 Amp Model
50 Hertz Models
450 Amp Model
650 Amp Model
Input Voltage (V)
380
400
440
380
400
440
380
400
440
Input Amperes (A) At Rated Output
35
33
31
54
51
47
75
71
65
Time-Delay Fuses 2
40
40
35
60
60
50
90
80
80
Normal Operating Fuses 3
60
50
50
80
80
70
125
110
100
10
10
10
8
8
8
6
6
6
243
(74)
269
(82)
326
(99)
218
(66)
241
(73)
292
(89)
219
(67)
242
(74)
293
(89)
10
10
10
8
8
8
6
6
8
Max Recommended Standard Fuse Rating In
Amperes 1
Min Input Conductor Size In AWG 4
Max Recommended Input Conductor Length
In Feet (Meters)
Min Grounding Conductor Size In AWG 4
Reference: 2008 National Electrical Code (NEC) (including article 630)
1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse.
2 “Time-Delay” fuses are UL class “RK5” . See UL 248.
3 “Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amps), and UL class “H” ( 65 amps and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.
OM-222 Page 23
4-16. Placing Jumper Links
!
Disconnect and lockout/tagout input power before
installing or moving jumper
links.
Check input voltage available at
site.
1
Jumper Link Label
Check label − only one is on unit.
2
Jumper Links
Move jumper links to match input
voltage.
Close and secure access door, or
go on to Section 4-17.
200 VOLTS
230 VOLTS
460 VOLTS
Ref. S-174 976-B
230 VOLTS
460 VOLTS
575 VOLTS
Ref. S-174 973-B
1
220 VOLTS
380 VOLTS
400 VOLTS
440 VOLTS
(FACTORY OPTION)
Ref. S-174 975-B
2
Tools Needed:
3/8 in
3/8 in
Do not overtighten
jumper link nuts.
Ref. 800 103-A
OM-222 Page 24
4-17. Connecting Input Power
3
= GND/PE Earth Ground
9
8
!
Installation must meet all National
and Local Codes − have only qualified persons make this installation.
!
Disconnect and lockout/tagout input power before connecting input
conductors from unit.
!
Make input power connections to
the welding power source first.
!
Always connect green or green/yellow conductor to supply grounding
terminal first, and never to a line terminal.
See rating label on unit and check input voltage available at site.
11
1
10
Input Power Conductors (Customer
Supplied Cord)
Select size and length of conductors using
Section 4-15. Conductors must comply with
national, state, and local electrical codes. If
applicable, use lugs of proper amperage
capacity and correct hole size.
2
4
7
Welding Power Source Input Power
Connections
2
1
IMPORTANT
6
3
Input Contactor
3
4
5
7 L2 (V)
L3 (W)
6
7
5
4
Machine Grounding Terminal
Green Or Green/Yellow Grounding
Conductor
Reed Switch (Ground Current
Sensor) (Optional)
Connect green or green/yellow grounding
conductor to welding power source grounding terminal first. If unit is equipped with optional ground current sensor, route grounding conductor through reed switch two
times and connect to grounding terminal.
L1 (U)
4
Strain Relief
Route conductors (cord) through strain relief and tighten screws.
3
= GND/ PE Earth Ground
Welding Power Source Line Terminals
Input Conductors L1 (U), L2 (V) And
L3 (W)
Connect input conductors L1 (U), L2 (V)
and L3 (W) to welding power source line terminals.
Close and secure access door on welding
power source.
Disconnect Device Input Power Connections
8
9
Disconnect Device (switch shown in
OFF position)
Disconnect Device (Supply)
Grounding Terminal
Connect green or green/yellow grounding
conductor to disconnect device grounding
terminal first.
10 Disconnect Device Line Terminals
Tools Needed:
3/8 in
3/8 in
Connect input conductors L1 (U), L2 (V)
And L3 (W) to disconnect device line
terminals.
11 Over-Current Protection
Select type and size of over-current protection using Section 4-15 (fused disconnect
switch shown).
Close and secure door on line disconnect
device. Remove lockout/tagout device, and
place switch in the On position.
800 103-C / Ref. 801 116-A
OM-222 Page 25
SECTION 5 − OPERATION
5-1. Controls (Non CE Models)
300 Amp Model Shown
1
2
9
3
5
4
8
7
6
Ref. 165 596-D
short arc length without sticking the electrode.
1
Polarity Selector Switch (Optional On 50
Hz Models)
To change polarity on models not equipped
with a Polarity Selector switch, reverse work
and electrode cables at the weld output terminals (see Section 4-11).
!
Turn Off Power before reversing
cables.
2 Arc Force (Dig) Control
Control increases SMAW short-circuit amperage which allows the operator to use a very
OM-222 Page 26
Set control at 0 for normal welding amperage.
Turn clockwise to increase short-circuit
amperage.
3
Hot Start Switch
Turn switch On for SMAW and Off for GTAW
welding.
4
5
6
7
Amperage Adjustment Control
Digital Meters (Optional)
Power Switch With Indicator Light
High Temperature Shutdown Light
8 Remote Amperage Control Switch
For front panel control, place switch in Panel
position. For remote control, place switch in
Remote position, and connect remote device
(see Section 4-14).
9 Output Switch (Contactor)
For front panel control of output, place switch
in Panel position. For remote control of output,
place switch in Remote position, and connect
remote device (see Section 4-14).
!
Turn Off power before connecting remote device.
5-2. Controls (CE Models)
300 Amp Model Shown
2
1
9
3
4
8
5
7
6
Ref. 173 450-B
1
Polarity Selector Switch (Optional On 50
Hz Models)
To change polarity on models not equipped
with a Polarity Selector switch, reverse work
and electrode cables at the weld output terminals (see Section 4-11).
!
Turn Off Power before reversing
cables.
2
Arc Force (Dig) Control
Control increases SMAW short-circuit amperage which allows the operator to use a very
short arc length without sticking the electrode.
8
Set control at 0 for normal welding amperage.
Turn clockwise to increase short-circuit
amperage.
For front panel control, place switch in Panel
position. For remote control, place switch in
Remote position, and connect remote device
(see Section 4-14).
3
Hot Start Switch
Turn switch On for SMAW and Off for GTAW
welding.
9
Remote Amperage Control Switch
Output Switch (Contactor)
4
Amperage Adjustment Control
5
Digital Meters (Optional)
For front panel control of output, place switch
in Panel position. For remote control of output,
place switch in Remote position, and connect
remote device (see Section 4-14).
6
Power Switch With Indicator Light
7
High Temperature Shutdown Light
!
Turn Off power before connecting remote device.
OM-222 Page 27
SECTION 6 − MAINTENANCE AND TROUBLESHOOTING
6-1. Routine Maintenance
!
Disconnect power before maintaining.
Maintain more often during severe conditions.
= Check
= Change
= Clean
* To be done by Factory Authorized Service Agent
Δ = Repair
= Replace
Every
3
Months
Labels
Weld Terminals
Every
3
Months
Δ Cables And Cords
Every
6
Months
:During heavy service, clean monthly.
6-2. Fuse F1
1
!
Turn Off power before opening rear access door.
1
Fuse F1 (See Parts List For
Rating)
Fuse F1 protects control transformer from overload. If F1 opens, weld
output and fan motor stops. Replace F1.
Close and secure access door.
Tools Needed:
3/8 in
OM-222 Page 28
Ref. 800 101-C
6-3. Troubleshooting
Trouble
No weld output; unit completely inoperative.
Remedy
Place line disconnect switch in On position (see Section 4-17).
Check fuse F1, and replace if necessary (see Section 6-2).
Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section 4-17).
Check for proper input power connections (see Section 4-17).
Check for proper jumper link position (see Section 4-16).
No weld output; Power switch pilot light
on; fan on.
If using remote control, place Output (Contactor) switch in Remote 14 position, and connect remote
control (see Section 4-14). If remote is not being used, place switch in On position.
Check, repair, or replace remote control.
Unit overheated. Allow unit to cool with fan On (see Section 4-4).
Have Factory Authorized Service Agent check control board PC1.
No weld output; Power switch pilot light Check for proper input power connections (see Section 4-17).
on; fan off.
Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section 4-17).
Have Factory Authorized Service Agent check SCR’s.
Unit provides only maximum or minimum weld output.
Have Factory Authorized Service Agent check control board PC1 and hall device HD1.
Erratic or improper weld output.
Use proper size and type of weld cable (see Section 4-10 and 4-11).
Clean and tighten all weld connections.
Check position of Polarity selector switch (see Section 5-1).
Have Factory Authorized Service Agent check control board PC1 and hall device HD1.
No 115 volts AC output at duplex receptacle, Remote 14 receptacle.
Reset supplementary protector CB1 (see Section 4-9).
No 24 volts AC output at Remote 14
receptacle.
Reset supplementary protector CB2 (see Section 4-9).
Fan not operating. Fan only runs when
cooling is necessary.
Check for and remove anything blocking fan movement.
Have Factory Authorized Service Agent check fan motor.
OM-222 Page 29
SECTION 7 − ELECTRICAL DIAGRAM
Figure 7-1. Circuit Diagram
OM-222 Page 30
218 518-C
OM-222 Page 31
21
23
8
29 - (Fig 8-3 & 4)
22
1
28 - (Fig 8-2)
27
3
2
24
4
5
6
7
11
10
4
13
15
12
9
14
16 17
3
19
not available unless listed.
20
Hardware is common and
22
18 - (Fig 8-5)
SECTION 8 − PARTS LIST
Figure 8-1. Main Assembly (452 Model Illustrated)
OM-222 Page 32
800 875-G
Item
No.
Diagram
marking
Part
No.
Description
Quantity
Model
302 452 652
402 602 852
Figure 8-1. Main Assembly
. . . 1 . . . . . . . . . . . . +179 430
. . . 1 . . . . . . . . . . . . +179 432
. . . 2 . . . . . . . . . . . . . 179 429
. . . 2 . . . . . . . . . . . . . 179 431
. . . 3 . . . . . . . . . . . . . 164 699
. . . 3 . . . . . . . . . . . . . 164 700
. . . 4 . . . . . . . . . . . . . 162 816
. . . 5 . . . . . . . . . . . . . 162 820
. . . 6 . . . . . . . . . . . . . 162 830
. . . 7 . . . . . . . . . . . . . 177 279
. . . 8 . . . . . . . . . . . . . 604 536
. . . 9 . . . . . . . . . . . . . 173 605
. . . 10 . . . . HD1 . . . . 168 829
. . . . . . . . . PLG14 . . 115 094
. . . 11 . . . . . Z1 . . . . 165 612
. . . 11 . . . . . Z1 . . . . 165 613
. . . 11 . . . . . Z1 . . . . 180 064
. . . . . . . . . . . . . . . . . . . 164 717
. . . 12 . . . C21-23 . . 163 906
. . . 13 . . . . . T2 . . . . 159 042
. . . 13 . . . . . T2 . . . . 159 041
. . . 13 . . . . . T2 . . . . 159 043
. . . 14 . . . . TE1 . . . . 159 244
. . . 15 . . . . . . . . . . . . . 601 835
. . . 16 . . . . . . . . . . . . . 038 887
. . . . . . . . . . . . . . . . . . . 010 913
. . . . . . . . . . . . . . . . . . . 601 835
. . . . . . . . . . . . . . . . . . . 038 618
. . . 17 . . . . . . . . . . . . . 159 034
. . . 18 . . . . . . . . . . . . . . Fig 8-5
. . . 19 . . . . . F1 . . . *156 065
. . . 20 . . . . . W . . . . . 160 760
. . . 20 . . . . . W . . . . . 160 793
. . . 20 . . . . . W . . . . . 160 794
. . . 21 . . . . CR4 . . ♦140 750
. . . 22 . . . . . . . . . . . . . 217 136
. . . 22 . . . . . . . . . . . . . 176 254
. . . 23 . . . . . . . . . . . . . 163 533
. . . 23 . . . . . . . . . . . . . 163 359
. . . 24 . . . . . T1 . . . . 218 399
. . . 24 . . . . . T1 . . . . 218 400
. . . 24 . . . . . T1 . . . . 218 402
. . . 24 . . . . . T1 . . . . 218 403
. . . 24 . . . . . T1 . . . . 218 405
. . . 24 . . . . . T1 . . . . 218 401
. . . 24 . . . . . T1 . . . . 218 404
. . . 24 . . . . . T1 . . . . 218 406
. . PANEL, side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . PANEL, side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 2
. . COVER, top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . COVER, top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1
. . BAFFLE, air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 2
. . BAFFLE, air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . CHANNEL, upright . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 . . . 4 . . . 4
. . BAR, mtg lift eye . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 2 . . . 2
. . LIFT EYE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . 1
. . GASKET, lift eye . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . 1
. . SCREW, .312-18 x 1.75 hexhd-pln gr 5 . . . . . . . . . . . . . . . . . . . 2 . . . 2 . . . 2
. . BRACKET, mtg LEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . 1
. . TRANSDUCER, current 1000A module . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . 1
. . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . 1
. . STABILIZER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . STABILIZER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . STABILIZER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . BUS BAR, stabilizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . CAPACITOR, 60 and 50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 . . . 3 . . . 3
. . TRANSFORMER, control 50VA 24V 230/460/575 (60Hz) . . . 1 . . . 1 . . . 1
. . TRANSFORMER, control 50VA 24V 200/230/460 (60Hz) . . . . . . . . . 1
. . TRANSFORMER, control 50VA 24V (50Hz) . . . . . . . . . . . . . . . 1 . . . 1 . . . 1
. . PRIMARY BOX, (includes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . 1
. . . . NUT, 10-32 brs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 . . 24 . . 24
. . . . STUD, pri bd brs 10-32 x 1.375 . . . . . . . . . . . . . . . . . . . . . . . 24 . . 24 . . 24
. . WASHER, flat .218 ID brs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 . . 24 . . 24
. . NUT, 10-32 brs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 . . 24 . . 24
. . LINK, jumper term bd pri . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 . . . 8 . . . 8
. . HOLDER, fuse mintr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . 1
. . PANEL, rear w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . 1
. . FUSE, crtg .5A 600V time delay . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . 1
. . CONTACTOR, def prp 40A 3P 24VAC . . . . . . . . . . . . . . . . . . . . 1
. . CONTACTOR, def prp 60A 3P 24VAC . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . CONTACTOR, def prp 75A 3P 24V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . SWITCH, reed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . 1
. . LABEL, warning electric shock . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 2 . . . 2
. . LABEL, general precautionary wordless,intl (CE models only) 2 . . . 2 . . . 2
. . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1
. . TRANSFORMER, pwr main 200/230/460 . . . . . . . . . . . . . . . . . 1
. . TRANSFORMER, pwr main 230/460/575 . . . . . . . . . . . . . . . . . 1
. . TRANSFORMER, pwr main 200/230/460 . . . . . . . . . . . . . . . . . . . . . . . 1
. . TRANSFORMER, pwr main 230/460/575 . . . . . . . . . . . . . . . . . . . . . . . 1
. . TRANSFORMER, pwr main 230/460/575 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . TRANSFORMER, pwr main 380/400/440 . . . . . . . . . . . . . . . . . 1
. . TRANSFORMER, pwr main 380/400/440 . . . . . . . . . . . . . . . . . . . . . . . 1
. . TRANSFORMER, pwr main 380/400/440 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
OM-222 Page 33
Item
No.
Diagram
marking
Part
No.
Description
Quantity
Model
302 452 652
402 602 852
Figure 8-1. Main Assembly (Continued)
. . . . . . . . . TP1,2 . . . 175 405
. . . . . . . . . TP4,5 . . . 168 891
. . . . . . . . . PLG13 . . 218 413
. . . . . . . . . RC13 . . . 218 408
. . . 27 . . . . . . . . . . . . . 161 294
. . . 28 . . . . . . . . . . . . . . Fig 8-2
. . . 29 . . . . SR1 . . . . 175 070
. . . 29 . . . . SR1 . . . . 192 672
. . . 29 . . . . SR1 . . . . 192 671
..
..
..
..
..
..
..
..
..
THERMOSTAT, NC (Included w/T1) . . . . . . . . . . . . . . . . . . . . . . 2 . . . 2 . . .
THERMOSTAT, NC (Included w/T1) . . . . . . . . . . . . . . . . . . . . . . 2 . . . 2 . . .
HOUSING, plug pin/skt (service kit) . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . .
HOUSING, plug pin/skt (service kit) . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . .
BRACKET, mtg rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 2 . . .
PANEL, front w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . .
RECTIFIER, si diode (Fig 8-3) . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
RECTIFIER, SCR main (Fig 8-4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
RECTIFIER, SCR main (Fig 8-4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
2
1
1
2
1
1
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
*Recommended Spare Parts.
♦Part of Option 195 048 Ground Current Sensor
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-222 Page 34
1
5
6
8
7
2
3
9
32
33
10
4
11
34
36
24
10
33
31
23
22
20
21
24
35
37
14
13
19
18
30
29
17
28
27
25
800 876-G
26
Figure 8-2. Panel, Front w/Components (452 Model Illustrated)
Item
No.
Diagram
marking
Part
No.
Description
Quantity
Model
302 452 652
402 602 852
Figure 8-2. Panel, Front w/Components (Fig 8-1 Item 28)
. . . 1 . . . . . S5 . . ♦169 331
. . . 1 . . . . . S5 . . ♦169 332
. . . 2 . . . . PC1 . . . . 207 042
. . . 2 . . . . PC1 . . . . 207 044
. . . 2 . . . . PC1 . . . . 207 047
. . . 2 . . . . PC1 . . . . 231 169
. . . 2 . . . . PC1 . . . . 231 165
. . . 2 . . . . PC1 . . . . 231 163
. . . . . . . . . PLG1 . . . 158 720
. . . . . . . . . PLG3 . . . 169 240
. . . . . . . . . PLG5 . . . 152 249
. . . 3 . . . . CR3 . . . . 052 964
. . . 4 . . . . CR5 . . . . 006 393
. . . 5 . . . CB1,2 . . . 093 995
. . . 6 . . . . RC9 . . . . 604 176
. . . 7 . . . . . . . . . . . . . 203 778
. . . . . . . . . . RC8 . . . . 143 976
. . . . . . . C3,6,13,14 . 097 749
. . . 8 . . . . . . . . . . . . . . 204143
. . . 9 . . . . POS . . . 181 245
. . . 10 . . . . C4,5 . . . 230 729
. . . 11 . . . . . . . . . . . . . 161 303
. . . 13 . . . . NEG . . . 181 246
. . SWITCH, mode polarity (single deck) . . . . . . . . . . . . . . . . . . . . . 1
. . SWITCH, mode polarity (double deck) . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . .
. . CIRCUIT CARD, control (60Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . CIRCUIT CARD, control (60Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . CIRCUIT CARD, control (60Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CIRCUIT CARD, control (50HZ) . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . CIRCUIT CARD, control (50HZ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . CIRCUIT CARD, control (50HZ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CONNECTOR & SOCKETS, (see Figs 8-3 & 8-4)
. . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . .
. . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . .
. . RELAY, encl 24VDC DPDT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . .
. . RELAY, encl 24VAC DPDT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . .
. . SUPPLEMENTARY PROTECTOR, man reset 1P 15A 250VAC2 . . . 2 . . .
. . RECEPTACLE, str dx grd 2P3W 15A 125V . . . . . . . . . . . . . . . . 1 . . . 1 . . .
. . CONNECTOR/CAPACITOR, w/leads (includes) . . . . . . . . . . . . 1 . . . 1 . . .
. . . . RCPT w/ SCKTS (service kit) . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . .
. . . . CAPACITOR, cer disc .05 UF 500 VDC strip . . . . . . . . . . . . 4 . . . 4 . . .
. . PANEL, front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . .
. . TERMINAL, pwr output red . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . .
. . CAPACITOR, cer disc .1uf 500VDC w/terms . . . . . . . . . . . . . . 2 . . . 2 . . .
. . SPRING, cprsn .600 OD x .072 wire x 1.500 lg . . . . . . . . . . . . 3 . . . 3 . . .
. . TERMINAL, pwr output black . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . .
1
1
1
1
1
1
1
2
1
1
1
4
1
1
2
3
1
OM-222 Page 35
Item
No.
Diagram
marking
Part
No.
Description
Quantity
Model
302 452 652
402 602 852
Figure 8-2. Panel, Front w/Components (Fig 8-1 Item 28) (Continued)
. . . 14 . . . . . . . . . . . . . 206 785 . . PLATE, control lower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 17 . . . . . . . . . . . . . 217 865 . . LABEL, warning electric shock and reduced air . . . . . . . . . . . .
. . . 17 . . . . . . . . . . . . . 179 563 . . LABEL, electric shock/reduce air flow (CE models only) . . . . . . .
. . . 18 . . . . . . . . . . . . +172 587 . . COVER, stud output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 19 . . . . . . . . . . . . . 160 935 . . CLIP, spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 20 . . . . . . . . . . . . . 601 835 . . NUT, 10-32 brs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . 010 913 . . WASHER, flat .218 ID x .460 OD x .031thk brs . . . . . . . . . . . .
. . . 21 . . . . . . . . . . . . . 159 863 . . ELECTRONICS BOX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . PLG6 . . . 168 847 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . RC6 . . . . 168 845 . . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . PLG7 . . . 152 249 . . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . RC7 . . . . 168 846 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 22 . . . . . . . . . . . . . 038 887 . . STUD, pri bd brs 10-32 x 1.375 . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 23 . . . S1,3,4 . . . 011 609 . . SWITCH, tgl SPDT 15A 125VAC . . . . . . . . . . . . . . . . . . . . . . . .
. . . 24 . . . . R1,2 . . . 198 087 . . POTENTIOMETER, CP std slot 1/T 2W 1K ohm . . . . . . . . . . .
. . . 25 . . . . . . . . . . . . . . . . . . . . . . . . NAMEPLATE, (order by model and serial number) . . . . . . . . .
. . . 26 . . . . . S2 . . . . 159 039 . . SWITCH, rocker SPDT 15A 125VAC . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . PLG2 . . . 185 626 . . CONNECTOR, body 56 series . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 27 . . . . PL2 . . . . 159 522 . . LED, yellow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 28 . . . . . . . . . . . . . 159 036 . . LENS, LED clear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 29 . . . . . . . . . . . . . 171 007 . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 30 . . . . . . . . . . . . . 193 919 . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 31 . . . . . . . . . . . ♦148 956 . . HANDLE, switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 32 . . . . SN1 . . . . 234 081 . . SNUBBER, assy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . ♦♦♦300 498 . . DIGITAL METER KIT, (includes) . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PC2 . . . . 231 149 . . . . CIRCUIT CARD, digital meter . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . PLG4,11 . . 148 439 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . PLG10 . . 153 501 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . 192 174 . . . . STAND-OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 33 . . . . . . . . . . . . . 010 381 . . . . CONNECTOR, rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 34 . . . . . . . . . . . . . 162 815 . . . . PANEL, front upper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 35 . . . . . . . . . . . . . 005 107 . . . . BOLT, crg stl .250-20 x .750 Gr 5 pld . . . . . . . . . . . . . . . . . . . . .
. . . 36 . . . . . . . . . . . . . 228 672 . . . . LABEL, weld cable lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 36 . . . . . . . . . . . . . 228 672 . . . . LABEL, caution output terminal connection . . . . . . . . . . . . . . . .
1
1
1
1
3
2
1
1
1
1
1
1
1
3
2
1
1
1
1
1
1
1
1
1
1
1
2
1
4
2
1
4
2
1
... 1
... 1
... 1
... 1
... 3
... 2
... 1
... 1
... 1
... 1
... 1
... 1
... 1
... 3
... 2
... 1
... 1
... 1
... 1
... 1
... 1
... 1
... 1
... 1
... 1
... 1
... 2
... 1
... 4
... 2
... 1
... 4
... 2
... 1
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
1
1
1
1
3
2
1
1
1
1
1
1
1
3
2
1
1
1
1
1
1
1
1
1
1
1
2
1
4
2
1
4
2
1
♦Standard w/60 Hz/Optional w/50 Hz
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
♦♦♦Optional
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-222 Page 36
Item
No.
Diagram
marking
Part
No.
SR1
175 070
. . . 1 . . . . C7-12 . . . .
... 2 ...............
... 3 ...............
... 4 ...............
. . . 5 . . . . . TP3 . . . . .
. . . 6 . . . . . TP6 . . . . .
. . . 7 . . . SCR1-6 . . .
. . . . . . . . . . PLG1 . . . .
... 8 ...............
Figure 8-3. Rectifier, Si Diode (302 Model) (Fig 8-1 Item 29)
048 420
177 316
177 317
166 667
185 679
206 083
161 668
158 720
188 692
..
..
..
..
..
..
..
..
..
3
1
Quantity
Description
CAPACITOR, cer disc .01uf 1000VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HEAT SINK, rect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HEAT SINK, rect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CLAMP, thyristor rect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
THERMOSTAT, NC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
THERMOSTAT, NC open 125F close 105F flange horizontal . . . . . . . . .
THYRISTOR, SCR 300A 300V hockey puck . . . . . . . . . . . . . . . . . . . . . . .
CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CLAMP, thyristor rectifier 4.250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6
3
2
3
1
1
6
1
3
4
5
2
6
7
2
3
1
ST-800 697-C
8
Figure 8-3. Rectifier, Si Diode SR1 (302 Model)
5
4
Hardware is common and
not available unless listed.
6
802 351
Figure 8-4. Rectifier, SCR Main SR1 (452 & 652 Model)
Item
No.
Diagram
marking
SR1
Part
No.
Description
Figure 8-4. Rectifier, SCR Main (452 & 652 Model)
(Fig 8-1 Item 29)
Quantity
192 672 192 671
. . . 1 . . . . C7-12 . . . . 048 420 . . CAPACITOR, cer disc .01uf 1000VDC . . . . . . . . . . . . . . . . . . . . . . . 6 . . . . 6
. . . 2 . . . . . . . . . . . . . . . 191 989 . . BAR, mtg rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2
. . . 3 . . . . . . . . . . . . . . . 188 691 . . CLAMP, thyristor rectifier 5.375 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 . . . . 3
. . . 4 . . . . . . . . . . . . . . . 188 839 . . HEAT SINK, rectifier snowflake .800 . . . . . . . . . . . . . . . . . . . . . . . . 12 . . 12
. . . 5 . . . SCR1-6 . . . 161 668 . . THYRISTOR, SCR 300A 300V hockey puck . . . . . . . . . . . . . . . . . . 6
. . . 5 . . . SCR1-6 . . . 148 091 . . THYRISTOR, SCR 865A 300V hockey puck . . . . . . . . . . . . . . . . . . . . . . . . 6
. . . 6 . . . . . . . . . . . . . . . 166 667 . . CLAMP, spring thyristor rectifier 5.500 . . . . . . . . . . . . . . . . . . . . . . . 3 . . . . 3
. . . . . . . . . . PLG1 . . . . 158 720 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . . . . . . . . . TP3 . . . . . 192 673 . . THERMOSTAT, rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . . . . . . . . . TP6 . . . . . 192 674 . . THERMOSTAT, rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-222 Page 37
Item
No.
Diagram
marking
Part
No.
Quantity
Description
Figure 8-5. Panel, Rear w/Components (Fig 8-1 Item 18)
...
...
...
...
...
...
...
...
...
...
...
1
2
3
4
5
6
6
8
9
10
11
. . . . . . . . . . . . . . . 173 283
. . . . . . . . . . . . . . . 180 165
. . . . . . . . . . . . . . . 162 807
. . . . . . . . . . . . . . . 168 343
. . . . . . . . . . . . . . +162 818
. . . . . . . . . . . . . . . 217 733
. . . . . . . . . . . . . . . 179 290
. . . . . . . . . . . . . . . 124 274
. . . . . R3 . . . . . . 097 459
. . . . . FM . . . . . 237 398
. . . . . . . . . . . . . . . 010 467
..
..
..
..
..
..
..
..
..
..
..
CHAMBER, plenum 14 in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BLADE, fan 14 in 3wg 23deg .375 bore CCW . . . . . . . . . . . . . . . . . . . . . .
PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HINGE, door primary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DOOR, access primary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LABEL, warning electric shock & input power (EN/FR) . . . . . . . . . . . . . .
LABEL, warning electric shock input connection (CE models only) . . .
BRACKET, mtg fan motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RESISTOR, WW fxd 375W 20 ohm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MOTOR, 1/12HP 230V 1550RPM 50/60Hz .83A . . . . . . . . . . . . . . . . . . .
CONNECTOR, clamp cable 1.250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
Hardware is common and
1
1
1
2
1
1
1
1
1
1
1
4
not available unless listed.
5
6
2
1
11
8
10
9
800 707-E
Figure 8-5. Panel, Rear w/Components
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-222 Page 38
Effective January 1, 2009
(Equipment with a serial number preface of LK or newer)
Warranty Questions?
Call
1-800-4-A-MILLER
for your local
Miller distributor.
Your distributor also gives
you ...
Service
You always get the fast,
reliable response you
need. Most replacement
parts can be in your
hands in 24 hours.
Support
Need fast answers to the
tough welding questions?
Contact your distributor.
The expertise of the
distributor and Miller is
there to help you, every
step of the way.
This limited warranty supersedes all previous Miller warranties and is exclusive with no other
guarantees or warranties expressed or implied.
LIMITED WARRANTY − Subject to the terms and conditions
* Induction Heating Coils and Blankets, Cables, and
below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants to
Non-Electronic Controls
its original retail purchaser that new Miller equipment sold after
* APT & SAF Model Plasma Cutting Torches
the effective date of this limited warranty is free of defects in
* Remote Controls
material and workmanship at the time it is shipped by Miller. THIS
* Accessory (Kits)
WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE
* Replacement Parts (No labor)
WARRANTIES OF MERCHANTABILITY AND FITNESS.
* Spoolmate Spoolguns
Within the warranty periods listed below, Miller will repair or
* Canvas Covers
replace any warranted parts or components that fail due to such
defects in material or workmanship. Miller must be notified in
writing within thirty (30) days of such defect or failure, at which
time Miller will provide instructions on the warranty claim
procedures to be followed.
Miller shall honor warranty claims on warranted equipment listed
below in the event of such a failure within the warranty time
periods. All warranty time periods start on the delivery date of the
equipment to the original end-user purchaser, and not to exceed
one year after the equipment is shipped to a North American
distributor or eighteen months after the equipment is shipped to
an International distributor.
1.
2.
3.
4.
5.
5 Years Parts — 3 Years Labor
* Original main power rectifiers only to include SCRs,
diodes, and discrete rectifier modules
3 Years — Parts and Labor
* Transformer/Rectifier Power Sources
* Plasma Arc Cutting Power Sources
* Process Controllers
* Semi-Automatic and Automatic Wire Feeders
* Inverter Power Sources (Unless Otherwise Stated)
* Water Coolant Systems (Integrated)
* Intellitig
* Engine Driven Welding Generators
(NOTE: Engines are warranted separately by the
engine manufacturer.)
1 Year — Parts and Labor Unless Specified
* Motor Driven Guns (w/exception of Spoolmate
Spoolguns)
* Positioners and Controllers
* Automatic Motion Devices
* RFCS Foot Controls
* Induction Heating Power Sources, Coolers, and
Electronic
Controls/Recorders
* Water Coolant Systems (Non-Integrated)
* Flowgauge and Flowmeter Regulators (No Labor)
* HF Units
* Grids
* Spot Welders
* Load Banks
* Fume Extractors
* Arc Stud Power Sources & Arc Stud Guns
* Racks
* Running Gear/Trailers
* Plasma Cutting Torches (except APT & SAF
Models)
* Field Options
(NOTE: Field options are covered under True Blue®
for the remaining warranty period of the product they
are installed in, or for a minimum of one year —
whichever is greater.)
* Bernard-Branded Mig Guns (No Labor)
* Weldcraft-Branded TIG Torches (No Labor)
* Subarc Wire Drive Assemblies
6 Months — Batteries
90 Days — Parts
* MIG Guns and Subarc (SAW) Guns
Miller’s True Blue® Limited Warranty shall not apply to:
1.
Consumable components; such as contact tips,
cutting nozzles, contactors, brushes, slip rings,
relays or parts that fail due to normal wear.
(Exception: brushes, slip rings, and relays are
covered on Bobcat, Trailblazer, and Legend
models.)
2.
Items furnished by Miller, but manufactured by others,
such as engines or trade accessories. These items are
covered by the manufacturer’s warranty, if any.
Equipment that has been modified by any party other
than Miller, or equipment that has been improperly
installed, improperly operated or misused based upon
industry standards, or equipment which has not had
reasonable and necessary maintenance, or equipment
which has been used for operation outside of the
specifications for the equipment.
3.
MILLER PRODUCTS ARE INTENDED FOR PURCHASE AND
USE BY COMMERCIAL/INDUSTRIAL USERS AND PERSONS
TRAINED AND EXPERIENCED IN THE USE AND
MAINTENANCE OF WELDING EQUIPMENT.
In the event of a warranty claim covered by this warranty, the
exclusive remedies shall be, at Miller’s option: (1) repair; or (2)
replacement; or, where authorized in writing by Miller in
appropriate cases, (3) the reasonable cost of repair or
replacement at an authorized Miller service station; or (4)
payment of or credit for the purchase price (less reasonable
depreciation based upon actual use) upon return of the goods at
customer’s risk and expense. Miller’s option of repair or
replacement will be F.O.B., Factory at Appleton, Wisconsin, or
F.O.B. at a Miller authorized service facility as determined by
Miller. Therefore no compensation or reimbursement for
transportation costs of any kind will be allowed.
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR
DIRECT,
INDIRECT,
SPECIAL,
INCIDENTAL
OR
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF
PROFIT), WHETHER BASED ON CONTRACT, TORT OR ANY
OTHER LEGAL THEORY.
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND
ANY
IMPLIED
WARRANTY,
GUARANTY
OR
REPRESENTATION AS TO PERFORMANCE, AND ANY
REMEDY FOR BREACH OF CONTRACT TORT OR ANY
OTHER LEGAL THEORY WHICH, BUT FOR THIS
PROVISION, MIGHT ARISE BY IMPLICATION, OPERATION
OF LAW, CUSTOM OF TRADE OR COURSE OF DEALING,
INCLUDING
ANY
IMPLIED
WARRANTY
OF
MERCHANTABILITY OR FITNESS FOR PARTICULAR
PURPOSE, WITH RESPECT TO ANY AND ALL EQUIPMENT
FURNISHED BY MILLER IS EXCLUDED AND DISCLAIMED
BY MILLER.
Some states in the U.S.A. do not allow limitations of how long an
implied warranty lasts, or the exclusion of incidental, indirect,
special or consequential damages, so the above limitation or
exclusion may not apply to you. This warranty provides specific
legal rights, and other rights may be available, but may vary from
state to state.
In Canada, legislation in some provinces provides for certain
additional warranties or remedies other than as stated herein,
and to the extent that they may not be waived, the limitations and
exclusions set out above may not apply. This Limited Warranty
provides specific legal rights, and other rights may be available,
but may vary from province to province.
miller_warr 2009−01
Owner’s Record
Please complete and retain with your personal records.
Model Name
Serial/Style Number
Purchase Date
(Date which equipment was delivered to original customer.)
Distributor
Address
City
State
Zip
For Service
Contact a DISTRIBUTOR or SERVICE AGENCY near you.
Always provide Model Name and Serial/Style Number.
Contact your Distributor for:
Welding Supplies and Consumables
Options and Accessories
Personal Safety Equipment
Service and Repair
Miller Electric Mfg. Co.
An Illinois Tool Works Company
1635 West Spencer Street
Appleton, WI 54914 USA
Replacement Parts
Training (Schools, Videos, Books)
Technical Manuals (Servicing Information
and Parts)
Circuit Diagrams
For International Locations Visit
www.MillerWelds.com
Welding Process Handbooks
To locate a Distributor or Service Agency visit
www.millerwelds.com or call 1-800-4-A-Miller
Contact the Delivering Carrier to:
File a claim for loss or damage during
shipment.
For assistance in filing or settling claims, contact
your distributor and/or equipment manufacturer’s
Transportation Department.
ORIGINAL INSTRUCTIONS − PRINTED IN USA
International Headquarters−USA
USA Phone: 920-735-4505 Auto-Attended
USA & Canada FAX: 920-735-4134
International FAX: 920-735-4125
© 2009 Miller Electric Mfg. Co.
2009−01

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Download PDF

advertisement