advertisement
▼
Scroll to page 2
of 44
OM-222 164 850AJ 2009−08 Processes TIG (GTAW) Welding Stick (SMAW) Welding Flux Cored (FCAW) Welding Air Carbon Arc (CAC-A) Cutting and Gouging Description Arc Welding Power Source Gold Star Series CE and non-CE 302, 452, 652 (60 Hz), 402, 602, 852 (50 Hz) File: Stick (SMAW) Visit our website at www.MillerWelds.com From Miller to You Thank you and congratulations on choosing Miller. Now you can get the job done and get it done right. We know you don’t have time to do it any other way. That’s why when Niels Miller first started building arc welders in 1929, he made sure his products offered long-lasting value and superior quality. Like you, his customers couldn’t afford anything less. Miller products had to be more than the best they could be. They had to be the best you could buy. Today, the people that build and sell Miller products continue the tradition. They’re just as committed to providing equipment and service that meets the high standards of quality and value established in 1929. This Owner’s Manual is designed to help you get the most out of your Miller products. Please take time to read the Safety precautions. They will help you protect yourself against potential hazards on the worksite. We’ve made installation and operation quick and easy. With Miller you can count on years of reliable service with proper maintenance. And if for some reason the unit needs repair, there’s a Troubleshooting section that will help you figure out what the problem is. The Miller is the first welding parts list will then help you to decide the equipment manufacturer in exact part you may need to fix the problem. the U.S.A. to be registered to the ISO 9001:2000 Quality Warranty and service information for your System Standard. particular model are also provided. Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual specification sheets. To locate your nearest distributor or service agency call 1-800-4-A-Miller, or visit us at www.MillerWelds.com on the web. Mil_Thank 4/05 Working as hard as you do − every power source from Miller is backed by the most hassle-free warranty in the business. TABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 3 1-4. California Proposition 65 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1-5. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 4 SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2-1. Symboles utilisés . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2-2. Dangers relatifs au soudage à l’arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance . . . . . . 5 7 2-4. Proposition californienne 65 Avertissements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2-5. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2-6. Informations relatives aux CEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 3 − DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 11 3-1. General Precautionary Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 3-2. Input Connection Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3. Electric Shock And Airflow Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 12 3-4. Nameplate Safety Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3-6. WEEE Label (For Products Sold Within The EU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 SECTION 4 − INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1. Important Information Regarding CE Products (Sold Within The EU) . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 14 4-2. Serial Number And Rating Label Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 4-3. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 4-4. Duty Cycle And Overheating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5. Volt-Ampere Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 16 4-6. Selecting A Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 4-7. Dimensions And Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8. Tipping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 19 4-9. 115 VAC Receptacle And Supplementary Protectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 4-10. Weld Output Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 4-11. Selecting Cable Sizes* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12. Connecting Weld Output Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 21 4-13. Remote 14 Receptacle Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 4-14. Connecting Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 4-15. Electrical Service Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16. Placing Jumper Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 24 4-17. Connecting Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 SECTION 5 − OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1. Controls (Non CE Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 26 5-2. Controls (CE Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 SECTION 6 − MAINTENANCE AND TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 6-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2. Fuse F1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 28 6-3. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 SECTION 7 − ELECTRICAL DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 SECTION 8 − PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OPTIONS AND ACCESSORIES 32 WARRANTY DECLARATION OF CONFORMITY for European Community (CE marked) products. MILLER Electric Mfg. Co., 1635 Spencer Street, Appleton, WI 54914 U.S.A. declares that the product(s) identified in this declaration conform to the essential requirements and provisions of the stated Council Directive(s) and Standard(s). Product/Apparatus Identification: Product Stock Number Goldstar 402 Goldstar 602 Goldstar 852 907362 907363 907364 Council Directives: 2006/95/EC Low Voltage 2004/108/EC Electromagnetic Compatibility Standards: IEC 609741:2005 Arc welding equipment – Part 1: Welding power sources IEC 6097410:2007 Arc Welding Equipment – Part 10: Electromagnetic compatibility (EMC) requirements EN 50445:2008 Product family standard to demonstrate compliance of equipment for resistance welding, arc welding and allied processes with the basic restrictions related to human exposure to electromagnetic fields (0 Hz – 300Hz) US Signatory: September 1, 2009 __________________________________________________________________________ David A. Werba Date of Declaration MANAGER, PRODUCT DESIGN COMPLIANCE 241428B SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _2009−08 7 Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage DANGER! − Indicates a hazardous situation which, if not avoided, will result in death or serious injury. The possible hazards are shown in the adjoining symbols or explained in the text. Indicates a hazardous situation which, if not avoided, could result in death or serious injury. The possible hazards are shown in the adjoining symbols or explained in the text. NOTICE − Indicates statements not related to personal injury. Indicates special instructions. This group of symbols means Warning! Watch Out! ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult symbols and related instructions below for necessary actions to avoid the hazards. 1-2. Arc Welding Hazards The symbols shown below are used throughout this manual to call attention to and identify possible hazards. When you see the symbol, watch out, and follow the related instructions to avoid the hazard. The safety information given below is only a summary of the more complete safety information found in the Safety Standards listed in Section 1-5. Read and follow all Safety Standards. Only qualified persons should install, operate, maintain, and repair this unit. During operation, keep everybody, especially children, away. ELECTRIC SHOCK can kill. Touching live electrical parts can cause fatal shocks or severe burns. The electrode and work circuit is electrically live whenever the output is on. The input power circuit and machine internal circuits are also live when power is on. In semiautomatic or automatic wire welding, the wire, wire reel, drive roll housing, and all metal parts touching the welding wire are electrically live. Incorrectly installed or improperly grounded equipment is a hazard. Do not touch live electrical parts. Wear dry, hole-free insulating gloves and body protection. Insulate yourself from work and ground using dry insulating mats or covers big enough to prevent any physical contact with the work or ground. Do not use AC output in damp areas, if movement is confined, or if there is a danger of falling. Use AC output ONLY if required for the welding process. If AC output is required, use remote output control if present on unit. Additional safety precautions are required when any of the following electrically hazardous conditions are present: in damp locations or while wearing wet clothing; on metal structures such as floors, gratings, or scaffolds; when in cramped positions such as sitting, kneeling, or lying; or when there is a high risk of unavoidable or accidental contact with the workpiece or ground. For these conditions, use the following equipment in order presented: 1) a semiautomatic DC constant voltage (wire) welder, 2) a DC manual (stick) welder, or 3) an AC welder with reduced open-circuit voltage. In most situations, use of a DC, constant voltage wire welder is recommended. And, do not work alone! Disconnect input power or stop engine before installing or servicing this equipment. Lockout/tagout input power according to OSHA 29 CFR 1910.147 (see Safety Standards). Properly install and ground this equipment according to its Owner’s Manual and national, state, and local codes. Always verify the supply ground − check and be sure that input power cord ground wire is properly connected to ground terminal in disconnect box or that cord plug is connected to a properly grounded receptacle outlet. When making input connections, attach proper grounding conductor first − double-check connections. Keep cords dry, free of oil and grease, and protected from hot metal and sparks. Frequently inspect input power cord for damage or bare wiring − replace cord immediately if damaged − bare wiring can kill. Turn off all equipment when not in use. Do not use worn, damaged, undersized, or poorly spliced cables. Do not drape cables over your body. If earth grounding of the workpiece is required, ground it directly with a separate cable. Do not touch electrode if you are in contact with the work, ground, or another electrode from a different machine. Do not touch electrode holders connected to two welding machines at the same time since double open-circuit voltage will be present. Use only well-maintained equipment. Repair or replace damaged parts at once. Maintain unit according to manual. Wear a safety harness if working above floor level. Keep all panels and covers securely in place. Clamp work cable with good metal-to-metal contact to workpiece or worktable as near the weld as practical. Insulate work clamp when not connected to workpiece to prevent contact with any metal object. Do not connect more than one electrode or work cable to any single weld output terminal. SIGNIFICANT DC VOLTAGE exists in inverter welding power sources AFTER removal of inputpower. Turn Off inverter, disconnect input power, and discharge input capacitors according to instructions in Maintenance Section before touching any parts. HOT PARTS can burn. Do not touch hot parts bare handed. Allow cooling period before working on equipment. To handle hot parts, use proper tools and/or wear heavy, insulated welding gloves and clothing to prevent burns. OM-222 Page 1 FUMES AND GASES can be hazardous. Welding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health. Keep your head out of the fumes. Do not breathe the fumes. If inside, ventilate the area and/or use local forced ventilation at the arc to remove welding fumes and gases. If ventilation is poor, wear an approved air-supplied respirator. Read and understand the Material Safety Data Sheets (MSDSs) and the manufacturer’s instructions for metals, consumables, coatings, cleaners, and degreasers. Work in a confined space only if it is well ventilated, or while wearing an air-supplied respirator. Always have a trained watchperson nearby. Welding fumes and gases can displace air and lower the oxygen level causing injury or death. Be sure the breathing air is safe. Do not weld in locations near degreasing, cleaning, or spraying operations. The heat and rays of the arc can react with vapors to form highly toxic and irritating gases. Do not weld on coated metals, such as galvanized, lead, or cadmium plated steel, unless the coating is removed from the weld area, the area is well ventilated, and while wearing an air-supplied respirator. The coatings and any metals containing these elements can give off toxic fumes if welded. Remove stick electrode from holder or cut off welding wire at contact tip when not in use. Wear oil-free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes, and a cap. Remove any combustibles, such as a butane lighter or matches, from your person before doing any welding. After completion of work, inspect area to ensure it is free of sparks, glowing embers, and flames. Use only correct fuses or circuit breakers. Do not oversize or bypass them. Follow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B for hot work and have a fire watcher and extinguisher nearby. FLYING METAL or DIRT can injure eyes. Welding, chipping, wire brushing, and grinding cause sparks and flying metal. As welds cool, they can throw off slag. Wear approved safety glasses with side shields even under your welding helmet. BUILDUP OF GAS can injure or kill. Shut off shielding gas supply when not in use. Always ventilate confined spaces or use approved air-supplied respirator. ARC RAYS can burn eyes and skin. Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld. Wear an approved welding helmet fitted with a proper shade of filter lenses to protect your face and eyes from arc rays and sparks when welding or watching (see ANSI Z49.1 and Z87.1 listed in Safety Standards). Wear approved safety glasses with side shields under your helmet. Use protective screens or barriers to protect others from flash, glare and sparks; warn others not to watch the arc. Wear protective clothing made from durable, flame-resistant material (leather, heavy cotton, or wool) and foot protection. WELDING can cause fire or explosion. Welding on closed containers, such as tanks, drums, or pipes, can cause them to blow up. Sparks can fly off from the welding arc. The flying sparks, hot workpiece, and hot equipment can cause fires and burns. Accidental contact of electrode to metal objects can cause sparks, explosion, overheating, or fire. Check and be sure the area is safe before doing any welding. Remove all flammables within 35 ft (10.7 m) of the welding arc. If this is not possible, tightly cover them with approved covers. Do not weld where flying sparks can strike flammable material. Protect yourself and others from flying sparks and hot metal. Be alert that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas. Watch for fire, and keep a fire extinguisher nearby. Be aware that welding on a ceiling, floor, bulkhead, or partition can cause fire on the hidden side. Do not weld on closed containers such as tanks, drums, or pipes, unless they are properly prepared according to AWS F4.1 (see Safety Standards). Do not weld where the atmosphere may contain flammable dust, gas, or liquid vapors (such as gasoline). Connect work cable to the work as close to the welding area as practical to prevent welding current from traveling long, possibly unknown paths and causing electric shock, sparks, and fire hazards. Do not use welder to thaw frozen pipes. OM-222 Page 2 ELECTRIC AND MAGNETIC FIELDS (EMF) can affect ImplantedMedical Devices. Wearers of Pacemakers and other Implanted Medical Devices should keep away. Implanted Medical Device wearers should consult their doctor and the device manufacturer before going near arc welding, spot welding, gouging, plasma arc cutting, or induction heating operations. NOISE can damage hearing. Noise from some processes or equipment can damage hearing. Wear approved ear protection if noise level is high. CYLINDERS can explode if damaged. Shielding gas cylinders contain gas under high pressure. If damaged, a cylinder can explode. Since gas cylinders are normally part of the welding process, be sure to treat them carefully. Protect compressed gas cylinders from excessive heat, mechanical shocks, physical damage, slag, open flames, sparks, and arcs. Install cylinders in an upright position by securing to a stationary support or cylinder rack to prevent falling or tipping. Keep cylinders away from any welding or other electrical circuits. Never drape a welding torch over a gas cylinder. Never allow a welding electrode to touch any cylinder. Never weld on a pressurized cylinder − explosion will result. Use only correct shielding gas cylinders, regulators, hoses, and fittings designed for the specific application; maintain them and associated parts in good condition. Turn face away from valve outlet when opening cylinder valve. Keep protective cap in place over valve except when cylinder is in use or connected for use. Use the right equipment, correct procedures, and sufficient number of persons to lift and move cylinders. Read and follow instructions on compressed gas cylinders, associated equipment, and Compressed Gas Association (CGA) publication P-1 listed in Safety Standards. 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. Do not install or place unit on, over, or near combustible surfaces. Do not install unit near flammables. Do not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit. FALLING EQUIPMENT can injure. Use lifting eye to lift unit only, NOT running gear, gas cylinders, or any other accessories. Use equipment of adequate capacity to lift and support unit. If using lift forks to move unit, be sure forks are long enough to extend beyond opposite side of unit. Keep equipment (cables and cords) away from moving vehicles when working from an aerial location. Follow the guidelines in the Applications Manual for the Revised NIOSH Lifting Equation (Publication No. 94−110) when manually lifting heavy parts or equipment. MOVING PARTS can injure. Keep away from moving parts such as fans. Keep all doors, panels, covers, and guards closed and securely in place. Have only qualified persons remove doors, panels, covers, or guards for maintenance and troubleshooting as necessary. Reinstall doors, panels, covers, or guards when maintenance is finished and before reconnecting input power. READ INSTRUCTIONS. Read and follow all labels and the Owner’s Manual carefully before installing, operating, or servicing unit. Read the safety information at the beginning of the manual and in each section. Use only genuine replacement parts from the manufacturer. Perform maintenance and service according to the Owner’s Manuals, industry standards, and national, state, and local codes. OVERUSE can cause OVERHEATING H.F. RADIATION can cause interference. Allow cooling period; follow rated duty cycle. Reduce current or reduce duty cycle before starting to weld again. Do not block or filter airflow to unit. FLYING SPARKS can injure. Wear a face shield to protect eyes and face. Shape tungsten electrode only on grinder with proper guards in a safe location wearing proper face, hand, and body protection. Sparks can cause fires — keep flammables away. STATIC (ESD) can damage PC boards. Put on grounded wrist strap BEFORE handling boards or parts. Use proper static-proof bags and boxes to store, move, or ship PC boards. ARC WELDING can cause interference. MOVING PARTS can injure. Keep away from moving parts. Keep away from pinch points such as drive rolls. WELDING WIRE can injure. Do not press gun trigger until instructed to do so. Do not point gun toward any part of the body, other people, or any metal when threading welding wire. High-frequency (H.F.) can interfere with radio navigation, safety services, computers, and communications equipment. Have only qualified persons familiar with electronic equipment perform this installation. The user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation. If notified by the FCC about interference, stop using the equipment at once. Have the installation regularly checked and maintained. Keep high-frequency source doors and panels tightly shut, keep spark gaps at correct setting, and use grounding and shielding to minimize the possibility of interference. Electromagnetic energy can interfere with sensitive electronic equipment such as computers and computer-driven equipment such as robots. Be sure all equipment in the welding area is electromagnetically compatible. To reduce possible interference, keep weld cables as short as possible, close together, and down low, such as on the floor. Locate welding operation 100 meters from any sensitive electronic equipment. Be sure this welding machine is installed and grounded according to this manual. If interference still occurs, the user must take extra measures such as moving the welding machine, using shielded cables, using line filters, or shielding the work area. OM-222 Page 3 1-4. California Proposition 65 Warnings Welding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer. (California Health & Safety Code Section 25249.5 et seq.) Battery posts, terminals and related accessories contain lead and lead compounds, chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling. For Gasoline Engines: Engine exhaust contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For Diesel Engines: Diesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and other reproductive harm. 1-5. Principal Safety Standards Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www.global.ihs.com). Safe Practices for the Preparation of Containers and Piping for Welding and Cutting, American Welding Society Standard AWS F4.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www.global.ihs.com). National Electrical Code, NFPA Standard 70, from National Fire Protection Association, Quincy, MA 02269 (phone: 1-800-344-3555, website: www.nfpa.org and www. sparky.org). Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, from Compressed Gas Association, 4221 Walney Road, 5th Floor, Chantilly, VA 20151 (phone: 703-788-2700, website:www.cganet.com). Safety in Welding, Cutting, and Allied Processes, CSA Standard W117.2, from Canadian Standards Association, Standards Sales, 5060 Spectrum Way, Suite 100, Ontario, Canada L4W 5NS (phone: 800-463-6727, website: www.csa-international.org). Safe Practice For Occupational And Educational Eye And Face Protection, ANSI Standard Z87.1, from American National Standards Institute, 25 West 43rd Street, New York, NY 10036 (phone: 212-642-4900, website: www.ansi.org). Standard for Fire Prevention During Welding, Cutting, and Other Hot Work, NFPA Standard 51B, from National Fire Protection Association, Quincy, MA 02269 (phone: 1-800-344-3555, website: www.nfpa.org. OSHA, Occupational Safety and Health Standards for General Industry, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q, and Part 1926, Subpart J, from U.S. Government Printing Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954 (phone: 1-866-512-1800) (there are 10 OSHA Regional Offices— phone for Region 5, Chicago, is 312-353-2220, website: www.osha.gov). U.S. Consumer Product Safety Commission (CPSC), 4330 East West Highway, Bethesda, MD 20814 (phone: 301-504-7923, website: www.cpsc.gov). Applications Manual for the Revised NIOSH Lifting Equation, The National Institute for Occupational Safety and Health (NIOSH), 1600 Clifton Rd, Atlanta, GA 30333 (phone: 1-800-232-4636, website: www.cdc.gov/NIOSH). 1-6. EMF Information Electric current flowing through any conductor causes localized electric and magnetic fields (EMF). Welding current creates an EMF field around the welding circuit and welding equipment. EMF fields may interfere with some medical implants, e.g. pacemakers. Protective measures for persons wearing medical implants have to be taken. For example, access restrictions for passers−by or individual risk assessment for welders. All welders should use the following procedures in order to minimize exposure to EMF fields from the welding circuit: 1. Keep cables close together by twisting or taping them, or using a cable cover. 2. Do not place your body between welding cables. Arrange cables to one side and away from the operator. 3. Do not coil or drape cables around your body. OM-222 Page 4 4. Keep head and trunk as far away from the equipment in the welding circuit as possible. 5. Connect work clamp to workpiece as close to the weld as possible. 6. Do not work next to, sit or lean on the welding power source. 7. Do not weld whilst carrying the welding power source or wire feeder. About Implanted Medical Devices: Implanted Medical Device wearers should consult their doctor and the device manufacturer before performing or going near arc welding, spot welding, gouging, plasma arc cutting, or induction heating operations. If cleared by your doctor, then following the above procedures is recommended. SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION fre_som_2009−08 7 Se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes. 2-1. Symboles utilisés DANGER! − Indique une situation dangereuse qui si on l’évite pas peut donner la mort ou des blessures graves. Les dangers possibles sont montrés par les symboles joints ou sont expliqués dans le texte. Indique une situation dangereuse qui si on l’évite pas peut donner la mort ou des blessures graves. Les dangers possibles sont montrés par les symboles joints ou sont expliqués dans le texte. NOTE − Indique des déclarations pas en relation avec des blessures personnelles. Indique des instructions spécifiques. Ce groupe de symboles veut dire Avertissement! Attention! DANGER DE CHOC ELECTRIQUE, PIECES EN MOUVEMENT, et PIECES CHAUDES. Consulter les symboles et les instructions ci-dessous y afférant pour les actions nécessaires afin d’éviter le danger. 2-2. Dangers relatifs au soudage à l’arc Les symboles représentés ci-dessous sont utilisés dans ce manuel pour attirer l’attention et identifier les dangers possibles. En présence de l’un de ces symboles, prendre garde et suivre les instructions afférentes pour éviter tout risque. Les instructions en matière de sécurité indiquées ci-dessous ne constituent qu’un sommaire des instructions de sécurité plus complètes fournies dans les normes de sécurité énumérées dans la Section 2-5. Lire et observer toutes les normes de sécurité. Seul un personnel qualifié est autorisé à installer, faire fonctionner, entretenir et réparer cet appareil. Pendant le fonctionnement, maintenir à distance toutes les personnes, notamment les enfants de l’appareil. UNE DÉCHARGE ÉLECTRIQUE peut entraîner la mort. Le contact d’organes électriques sous tension peut provoquer des accidents mortels ou des brûlures graves. Le circuit de l’électrode et de la pièce est sous tension lorsque le courant est délivré à la sortie. Le circuit d’alimentation et les circuits internes de la machine sont également sous tension lorsque l’alimentation est sur Marche. Dans le mode de soudage avec du fil, le fil, le dérouleur, le bloc de commande du rouleau et toutes les parties métalliques en contact avec le fil sont sous tension électrique. Un équipement installé ou mis à la terre de manière incorrecte ou impropre constitue un danger. Ne pas toucher aux pièces électriques sous tension. Porter des gants isolants et des vêtements de protection secs et sans trous. S’isoler de la pièce à couper et du sol en utilisant des housses ou des tapis assez grands afin d’éviter tout contact physique avec la pièce à couper ou le sol. Ne pas se servir de source électrique à courant électrique dans les zones humides, dans les endroits confinés ou là où on risque de tomber. Se servir d’une source électrique à courant électrique UNIQUEMENT si le procédé de soudage le demande. Si l’utilisation d’une source électrique à courant électrique s’avère nécessaire, se servir de la fonction de télécommande si l’appareil en est équipé. D’autres consignes de sécurité sont nécessaires dans les conditions suivantes : risques électriques dans un environnement humide ou si l’on porte des vêtements mouillés ; sur des structures métalliques telles que sols, grilles ou échafaudages ; en position coincée comme assise, à genoux ou couchée ; ou s’il y a un risque élevé de contact inévitable ou accidentel avec la pièce à souder ou le sol. Dans ces conditions, utiliser les équipements suivants, dans l’ordre indiqué : 1) un poste à souder DC à tension constante (à fil), 2) un poste à souder DC manuel (électrode) ou 3) un poste à souder AC à tension à vide réduite. Dans la plupart des situations, l’utilisation d’un poste à souder DC à fil à tension constante est recommandée. En outre, ne pas travailler seul ! Couper l’alimentation ou arrêter le moteur avant de procéder à l’installation, à la réparation ou à l’entretien de l’appareil. Déverrouiller l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de sécurité). Installer le poste correctement et le mettre à la terre convenablement selon les consignes du manuel de l’opérateur et les normes nationales, provinciales et locales. Toujours vérifier la terre du cordon d’alimentation. Vérifier et s’assurer que le fil de terre du cordon d’alimentation est bien raccordé à la borne de terre du sectionneur ou que la fiche du cordon est raccordée à une prise correctement mise à la terre. En effectuant les raccordements d’entrée, fixer d’abord le conducteur de mise à la terre approprié et contre-vérifier les connexions. Les câbles doivent être exempts d’humidité, d’huile et de graisse; protégez−les contre les étincelles et les pièces métalliques chaudes. Vérifier fréquemment le cordon d’alimentation afin de s’assurer qu’il n’est pas altéré ou à nu, le remplacer immédiatement s’il l’est. Un fil à nu peut entraîner la mort. L’équipement doit être hors tension lorsqu’il n’est pas utilisé. Ne pas utiliser des câbles usés, endommagés, de grosseur insuffisante ou mal épissés. Ne pas enrouler les câbles autour du corps. Si la pièce soudée doit être mise à la terre, le faire directement avec un câble distinct. Ne pas toucher l’électrode quand on est en contact avec la pièce, la terre ou une électrode provenant d’une autre machine. Ne pas toucher des porte électrodes connectés à deux machines en même temps à cause de la présence d’une tension à vide doublée. N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-lechamp les pièces endommagées. Entretenir l’appareil conformément à ce manuel. Porter un harnais de sécurité si l’on doit travailler au-dessus du sol. S’assurer que tous les panneaux et couvercles sont correctement en place. Fixer le câble de retour de façon à obtenir un bon contact métalmétal avec la pièce à souder ou la table de travail, le plus près possible de la soudure. Isoler la pince de masse quand pas mis à la pièce pour éviter le contact avec tout objet métallique. Ne pas raccorder plus d’une électrode ou plus d’un câble de masse à une même borne de sortie de soudage. OM-222 Page 5 Il reste une TENSION DC NON NÉGLIGEABLE dans les sources de soudage onduleur UNE FOIS l’alimentation coupée. Arrêter les convertisseurs, débrancher le courant électrique et décharger les condensateurs d’alimentation selon les instructions indiquées dans la partie Entretien avant de toucher les pièces. LES PIÈCES CHAUDES peuvent provoquer des brûlures. Ne pas toucher à mains nues les parties chaudes. Prévoir une période de refroidissement avant de travailler à l’équipement. Ne pas toucher aux pièces chaudes, utiliser les outils recommandés et porter des gants de soudage et des vêtements épais pour éviter les brûlures. LES FUMÉES ET LES GAZ peuvent être dangereux. Le soudage génère des fumées et des gaz. Leur inhalation peut être dangereux pour votre santé. Eloigner votre tête des fumées. Ne pas respirer les fumées. À l’intérieur, ventiler la zone et/ou utiliser une ventilation forcée au niveau de l’arc pour l’évacuation des fumées et des gaz de soudage. Si la ventilation est médiocre, porter un respirateur anti-vapeurs approuvé. Porter des vêtements confectionnés avec des matières résistantes et ignifuges (cuir, coton lourd ou laine) et des bottes de protection. LE SOUDAGE peut provoquer un incendie ou une explosion. Le soudage effectué sur des conteneurs fermés tels que des réservoirs, tambours ou des conduites peut provoquer leur éclatement. Des étincelles peuvent être projetées de l’arc de soudure. La projection d’étincelles, des pièces chaudes et des équipements chauds peut provoquer des incendies et des brûlures. Le contact accidentel de l’électrode avec des objets métalliques peut provoquer des étincelles, une explosion, un surchauffement ou un incendie. Avant de commencer le soudage, vérifier et s’assurer que l’endroit ne présente pas de danger. Déplacer toutes les substances inflammables à une distance de 10,7 m de l’arc de soudage. En cas d’impossibilité les recouvrir soigneusement avec des protections homologués. Ne pas souder dans un endroit là où des étincelles peuvent tomber sur des substances inflammables. Se protéger et d’autres personnes de la projection d’étincelles et de métal chaud. Des étincelles et des matériaux chauds du soudage peuvent facilement passer dans d’autres zones en traversant de petites fissures et des ouvertures. Surveiller tout déclenchement d’incendie et tenir un extincteur à proximité. Le soudage effectué sur un plafond, plancher, paroi ou séparation peut déclencher un incendie de l’autre côté. Ne pas effectuer le soudage sur des conteneurs fermés tels que des réservoirs, tambours, ou conduites, à moins qu’ils n’aient été préparés correctement conformément à AWS F4.1 (voir les normes de sécurité). Lire et comprendre les spécifications de sécurité des matériaux (MSDS) et les instructions du fabricant concernant les métaux, les consommables, les revêtements, les nettoyants et les dégraisseurs. Ne soudez pas si l’air ambiant est chargé de particules, gaz, ou vapeurs inflammables (vapeur d’essence, par exemple). Travailler dans un espace fermé seulement s’il est bien ventilé ou en portant un respirateur à alimentation d’air. Demander toujours à un surveillant dûment formé de se tenir à proximité. Des fumées et des gaz de soudage peuvent déplacer l’air et abaisser le niveau d’oxygène provoquant des blessures ou des accidents mortels. S’assurer que l’air de respiration ne présente aucun danger. Ne pas utiliser le poste de soudage pour dégeler des conduites gelées. Ne pas souder dans des endroits situés à proximité d’opérations de dégraissage, de nettoyage ou de pulvérisation. La chaleur et les rayons de l’arc peuvent réagir en présence de vapeurs et former des gaz hautement toxiques et irritants. Ne pas souder des métaux munis d’un revêtement, tels que l’acier galvanisé, plaqué en plomb ou au cadmium à moins que le revêtement n’ait été enlevé dans la zone de soudure, que l’endroit soit bien ventilé, et en portant un respirateur à alimentation d’air. Les revêtements et tous les métaux renfermant ces éléments peuvent dégager des fumées toxiques en cas de soudage. LES RAYONS DE L’ARC peuvent provoquer des brûlures dans les yeux et sur la peau. Le rayonnement de l’arc du procédé de soudage génère des rayons visibles et invisibles intense (ultraviolets et infrarouges) susceptibles de provoquer des brûlure dans les yeux et sur la peau. Des étincelles sont projetées pendant le soudage. Porter un casque de soudage approuvé muni de verres filtrants approprié pour protéger visage et yeux pour protéger votre visage et vos yeux pendant le soudage ou pour regarder (voir ANSI Z49.1 et Z87.1 énuméré dans les normes de sécurité). Porter des lunettes de sécurité avec écrans latéraux même sous votre casque. Avoir recours à des écrans protecteurs ou à des rideaux pour protéger les autres contre les rayonnements les éblouissements et les étincelles ; prévenir toute personne sur les lieux de ne pas regarder l’arc. OM-222 Page 6 Brancher le câble de masse sur la pièce le plus près possible de la zone de soudage pour éviter le transport du courant sur une longue distance par des chemins inconnus éventuels en provoquant des risques d’électrocution, d’étincelles et d’incendie. En cas de non utilisation, enlever la baguette d’électrode du porteélectrode ou couper le fil à la pointe de contact. Porter des vêtements de protection dépourvus d’huile tels que des gants en cuir, une chemise en matériau lourd, des pantalons sans revers, des chaussures hautes et un couvre chef. Avant de souder, retirer toute substance combustible de vos poches telles qu’un allumeur au butane ou des allumettes. Une fois le travail achevé, assurez−vous qu’il ne reste aucune trace d’étincelles incandescentes ni de flammes. Utiliser exclusivement des fusibles ou coupe−circuits appropriés. Ne pas augmenter leur puissance; ne pas les ponter. Une fois le travail achevé, assurez−vous qu’il ne reste aucune trace d’étincelles incandescentes ni de flammes. Utiliser exclusivement des fusibles ou coupe−circuits appropriés. Ne pas augmenter leur puissance; ne pas les ponter. Suivre les recommandations dans OSHA 1910.252(a)(2)(iv) et NFPA 51B pour les travaux à chaud et avoir de la surveillance et un extincteur à proximité. DES PIECES DE METAL ou DES SALETES peuvent provoquer des blessures dans les yeux. Le soudage, l’écaillement, le passage de la pièce à la brosse en fil de fer, et le meulage génèrent des étincelles et des particules métalliques volantes. Pendant la période de refroidissement des soudures, elles risquent de projeter du laitier. Porter des lunettes de sécurité avec écrans latéraux ou un écran facial. LES ACCUMULATIONS DE GAZ risquent de provoquer des blessures ou même la mort. Fermer l’alimentation du gaz protecteur en cas de non-utilisation. Veiller toujours à bien aérer les espaces confinés ou se servir d’un respirateur d’adduction d’air homologué. Les CHAMPS ÉLECTROMAGNÉTIQUES (CEM) peuvent affecter les implants médicaux. Les porteurs de stimulateurs cardiaques et autres implants médicaux doivent rester à distance. Les porteurs d’implants médicaux doivent consulter leur médecin et le fabricant du dispositif avant de s’approcher de la zone où se déroule du soudage à l’arc, du soudage par points, du gougeage, de la découpe plasma ou une opération de chauffage par induction. LES BOUTEILLES peuvent exploser si elles sont endommagées. Des bouteilles de gaz protecteur contiennent du gaz sous haute pression. Si une bouteille est endommagée, elle peut exploser. Du fait que les bouteilles de gaz font normalement partie du procédé de soudage, les manipuler avec précaution. Protéger les bouteilles de gaz comprimé d’une chaleur excessive, des chocs mécaniques, des dommages physiques, du laitier, des flammes ouvertes, des étincelles et des arcs. Placer les bouteilles debout en les fixant dans un support stationnaire ou dans un porte-bouteilles pour les empêcher de tomber ou de se renverser. Tenir les bouteilles éloignées des circuits de soudage ou autres circuits électriques. Ne jamais placer une torche de soudage sur une bouteille à gaz. Une électrode de soudage ne doit jamais entrer en contact avec une bouteille. Ne jamais souder une bouteille pressurisée − risque d’explosion. Utiliser seulement des bouteilles de gaz protecteur, régulateurs, tuyaux et raccords convenables pour cette application spécifique ; les maintenir ainsi que les éléments associés en bon état. Détourner votre visage du détendeur-régulateur lorsque vous ouvrez la soupape de la bouteille. LE BRUIT peut endommager l’ouïe. Le bruit des processus et des équipements peut affecter l’ouïe. Porter des protections approuvées pour les oreilles si le niveau sonore est trop élevé. Le couvercle du détendeur doit toujours être en place, sauf lorsque la bouteille est utilisée ou qu’elle est reliée pour usage ultérieur. Utiliser les équipements corrects, les bonnes procédures et suffisamment de personnes pour soulever et déplacer les bouteilles. Lire et suivre les instructions sur les bouteilles de gaz comprimé, l’équipement connexe et le dépliant P-1 de la CGA (Compressed Gas Association) mentionné dans les principales normes de sécurité. 2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance Risque D’INCENDIE OU D’EXPLOSION. Ne pas placer l’appareil sur, au-dessus ou à proximité de surfaces inflammables. Ne pas installer l’appareil à proximité de produits inflammables. Ne pas surcharger l’installation électrique − s’assurer que l’alimentation est correctement dimensionnée et protégée avant de mettre l’appareil en service. LA CHUTE DE L’ÉQUIPEMENT peut provoquer des blessures. Utiliser l’anneau de levage uniquement pour soulever l’appareil, NON PAS les chariots, les bouteilles de gaz ou tout autre accessoire. Utiliser un équipement de levage de capacité suffisante pour lever l’appareil. En utilisant des fourches de levage pour déplacer l’unité, s’assurer que les fourches sont suffisamment longues pour dépasser du côté opposé de l’appareil. Tenir l’équipement (câbles et cordons) à distance des véhicules mobiles lors de toute opération en hauteur. Suivre les consignes du Manuel des applications pour l’équation de levage NIOSH révisée (Publication Nº94–110) lors du levage manuelle de pièces ou équipements lourds. L’EMPLOI EXCESSIF peut SURCHAUFFER L’ÉQUIPEMENT. Prévoir une période de refroidissement ; respecter le cycle opératoire nominal. Réduire le courant ou le facteur de marche avant de poursuivre le soudage. Ne pas obstruer les passages d’air du poste. LES ÉTINCELLES PROJETÉES peuvent provoquer des blessures. Porter un écran facial pour protéger le visage et les yeux. Affûter l’électrode au tungstène uniquement à la meuleuse dotée de protecteurs. Cette manœuvre est à exécuter dans un endroit sûr lorsque l’on porte l’équipement homologué de protection du visage, des mains et du corps. Les étincelles risquent de causer un incendie − éloigner toute substance inflammable. LES CHARGES ÉLECTROSTATIQUES peuvent endommager les circuits imprimés. Établir la connexion avec la barrette de terre avant de manipuler des cartes ou des pièces. Utiliser des pochettes et des boîtes antistatiques pour stocker, déplacer ou expédier des cartes de circuits imprimes. OM-222 Page 7 Les PIÈCES MOBILES peuvent causer des blessures. LE RAYONNEMENT HAUTE FRÉQUENCE (H.F.) risque de provoquer des interférences. Ne pas s’approcher des organes mobiles. Ne pas s’approcher des points de coincement tels que des rouleaux de commande. LES FILS DE SOUDAGE peuvent provoquer des blessures. Ne pas appuyer sur la gâchette avant d’en avoir reçu l’instruction. Ne pas diriger le pistolet vers soi, d’autres personnes ou toute pièce mécanique en engageant le fil de soudage. Les PIÈCES MOBILES peuvent causer des blessures. S’abstenir de toucher des organes mobiles tels que des ventilateurs. Maintenir fermés et verrouillés les portes, panneaux, recouvrements et dispositifs de protection. Lorsque cela est nécessaire pour des travaux d’entretien et de dépannage, faire retirer les portes, panneaux, recouvrements ou dispositifs de protection uniquement par du personnel qualifié. Remettre les portes, panneaux, recouvrements ou dispositifs de protection quand l’entretien est terminé et avant de rebrancher l’alimentation électrique. LIRE LES INSTRUCTIONS. Lire et appliquer les instructions sur les étiquettes et le Mode d’emploi avant l’installation, l’utilisation ou l’entretien de l’appareil. Lire les informations de sécurité au début du manuel et dans chaque section. N’utiliser que les pièces de rechange recommandées par le constructeur. Effectuer l’entretien en respectant les manuels d’utilisation, les normes industrielles et les codes nationaux, d’état et locaux. Le rayonnement haute fréquence (H.F.) peut provoquer des interférences avec les équipements de radio−navigation et de communication, les services de sécurité et les ordinateurs. Demander seulement à des personnes qualifiées familiarisées avec des équipements électroniques de faire fonctionner l’installation. L’utilisateur est tenu de faire corriger rapidement par un électricien qualifié les interférences résultant de l’installation. Si le FCC signale des interférences, arrêter immédiatement l’appareil. Effectuer régulièrement le contrôle et l’entretien de l’installation. Maintenir soigneusement fermés les portes et les panneaux des sources de haute fréquence, maintenir les éclateurs à une distance correcte et utiliser une terre et un blindage pour réduire les interférences éventuelles. LE SOUDAGE À L’ARC risque de provoquer des interférences. L’énergie électromagnétique risque de provoquer des interférences pour l’équipement électronique sensible tel que les ordinateurs et l’équipement commandé par ordinateur tel que les robots. Veiller à ce que tout l’équipement de la zone de soudage soit compatible électromagnétiquement. Pour réduire la possibilité d’interférence, maintenir les câbles de soudage aussi courts que possible, les grouper, et les poser aussi bas que possible (ex. par terre). Veiller à souder à une distance de 100 mètres de tout équipement électronique sensible. Veiller à ce que ce poste de soudage soit posé et mis à la terre conformément à ce mode d’emploi. En cas d’interférences après avoir pris les mesures précédentes, il incombe à l’utilisateur de prendre des mesures supplémentaires telles que le déplacement du poste, l’utilisation de câbles blindés, l’utilisation de filtres de ligne ou la pose de protecteurs dans la zone de travail. 2-4. Proposition californienne 65 Avertissements Les équipements de soudage et de coupage produisent des fumées et des gaz qui contiennent des produits chimiques dont l’État de Californie reconnaît qu’ils provoquent des malformations congénitales et, dans certains cas, des cancers. (Code de santé et de sécurité de Californie, chapitre 25249.5 et suivants) Les batteries, les bornes et autres accessoires contiennent du plomb et des composés à base de plomb, produits chimiques dont l’État de Californie reconnaît qu’ils provoquent des cancers et des malformations congénitales ou autres problèmes de procréation. Se laver les mains après manipulation. OM-222 Page 8 Pour les moteurs à essence : Les gaz d’échappement des moteurs contiennent des produits chimiques dont l’État de Californie reconnaît qu’ils provoquent des cancers et des malformations congénitales ou autres problèmes de procréation. Pour les moteurs diesel : Les gaz d’échappement des moteurs diesel et certains de leurs composants sont reconnus par l’État de Californie comme provoquant des cancers et des malformations congénitales ou autres problèmes de procréation. 2-5. Principales normes de sécurité Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1, de Global Engineering Documents (téléphone : 1-877-413-5184, site Internet : www.global.ihs.com). Safe Practices for the Preparation of Containers and Piping for Welding and Cutting, American Welding Society Standard AWS F4.1, de Global Engineering Documents (téléphone : 1-877-413-5184, site internet : www.global.ihs.com). National Electrical Code, NFPA Standard 70, de National Fire Protection Association, Quincy, MA 02269 (téléphone : 800-344-3555, site Internet : www.nfpa.org et www.sparky.org). Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, de Compressed Gas Association, 4221 Walney Road, 5th Floor, Chantilly, VA 20151 (téléphone : 703-788-2700, site Internet : www.cganet.com). Safety in Welding, Cutting, and Allied Processes, CSA Standard W117.2, de Canadian Standards Association, Standards Sales, 5060 Spectrum Way, Suite 100, Ontario, Canada L4W 5NS (téléphone : 800-463-6727, site internet : www.csa-international.org). Safe Practice For Occupational And Educational Eye And Face Protection, ANSI Standard Z87.1, de American National Standards Institute, 25 West 43rd Street, New York, NY 10036 (téléphone : 212-642-4900, site Internet : www.ansi.org). Standard for Fire Prevention During Welding, Cutting, and Other Hot Work, NFPA Standard 51B, de National Fire Protection Association, P.O. Box 9101, Quincy, MA 02269-9101 (téléphone : 617-770-3000, site Internet : www.nfpa.org). OSHA, Occupational Safety and Health Standards for General Industry, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q, and Part 1926, Subpart J, de U.S. Government Printing Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954 (téléphone : 1-866-512-1800) (il y a 10 bureaux régionaux−le téléphone de la région 5, Chicago, est 312-353-2220, site Internet : www.osha.gov). U.S. Consumer Product Safety Commission (CPSC), 4330 East West Highway, Bethesda, MD 20814 (téléphone : 301-504-7923, site internet : www.cpsc.gov). Applications Manual for the Revised NIOSH Lifting Equation, The National Institute for Occupational Safety and Health (NIOSH), 1600 Clifton Rd, Atlanta, GA 30333 (télé[hone : 1-800-232-4636, site internet: www.cdc.gov/NIOSH). 2-6. Informations relatives aux CEM Le courant électrique qui traverse tout conducteur génère des champs électromagnétiques (CEM) à certains endroits. Le courant de soudage crée un CEM autour du circuit et du matériel de soudage. Les CEM peuvent créer des interférences avec certains implants médicaux comme des stimulateurs cardiaques. Des mesures de protection pour les porteurs d’implants médicaux doivent être prises: par exemple, des restrictions d’accès pour les passants ou une évaluation individuelle des risques pour les soudeurs. Tous les soudeurs doivent appliquer les procédures suivantes pour minimiser l’exposition aux CEM provenant du circuit de soudage: 4 Maintenir la tête et le torse aussi loin que possible du matériel du circuit de soudage. 5 Connecter la pince sur la pièce aussi près que possible de la soudure. 6 Ne pas travailler à proximité d’une source de soudage, ni s’asseoir ou se pencher dessus. 7 Ne pas souder tout en portant la source de soudage ou le dévidoir. 1 En ce qui concerne les implants médicaux : 2 3 Rassembler les câbles en les torsadant ou en les attachant avec du ruban adhésif ou avec une housse. Ne pas se tenir au milieu des câbles de soudage. Disposer les câbles d’un côté et à distance de l’opérateur. Ne pas courber et ne pas entourer les câbles autour de votre corps. Les porteurs d’implants doivent d’abord consulter leur médecin avant de s’approcher des opérations de soudage à l’arc, de soudage par points, de gougeage, du coupage plasma ou de chauffage par induction. Si le médecin approuve, il est recommandé de suivre les procédures précédentes. OM-222 Page 9 OM-222 Page 10 SECTION 3 − DEFINITIONS 3-1. General Precautionary Label Warning! Watch Out! There are possible hazards as shown by the symbols. 1 1.1 1.2 1.3 2 2.1 2.2 2.3 3 3.1 3.2 3.3 4 4.1 5 6 Electric shock from welding electrode or wiring can kill. Wear dry insulating gloves. Do not touch electrode with bare hand. Do not wear wet or damaged gloves. Protect yourself from electric shock by insulating yourself from work and ground. Disconnect input plug or power before working on machine. Breathing welding fumes can be hazardous to your health. Keep your head out of the fumes. Use forced ventilation or local exhaust to remove the fumes. Use ventilating fan to remove fumes. Welding sparks can cause explosion or fire. Keep flammables away from welding. Do not weld near flammables. Welding sparks can cause fires. Have a fire extinguisher nearby, and have a watchperson ready to use it. Do not weld on drums or any closed containers. Arc rays can burn eyes and injure skin. Wear hat and safety glasses. Use ear protection and button shirt collar. Use welding helmet with correct shade of filter. Wear complete body protection. Become trained and read the instructions before working on the machine or welding. Do not remove or paint over (cover) the label. OM-222 Page 11 3-2. Input Connection Label 1 2 3 4 1 Warning! Watch Out! There are possible hazards as shown by the symbols. Electric shock from wiring can kill. Disconnect input plug or power before working on machine. Read the Owner’s Manual before working on this machine. Consult rating label for input power requirements, and check power available at the job site − they must match. Read Owner’s Manual and inside labels for connection points and procedures. Move jumper links as shown on inside label to match voltage at job site. Having a loop of extra length, connect grounding conductor first. Connect line input conductors as shown on inside label − double-check all connections, jumper link positions, and input voltage before applying power. 2 3 4 1 2 ? V ? A 3 ? 5 V 6 ÍÍÍ ÍÍÍ ÍÍÍ ÍÍÍ ÍÍÍ 5 6 7 5 3 8 4 S-179 290 7 8 9 9 1/96 3-3. Electric Shock And Airflow Label 1 2 1 3 2 3 S-179 563 Warning! Watch Out! There are possible hazards as shown by the symbols. Electric shock from wiring and exposed weld terminals can kill. Close door before turning on unit. 1/96 3-4. Nameplate Safety Symbols 1 1 1 2 3 4 5 2 3 4 5 6 6 Warning! Watch Out! There are possible hazards as shown by the symbols. Electric shock from welding electrode or wiring can kill. Sparks from arcing electrode can cause explosion or fire − disconnect cable for process not in use. Read Owner’s Manual for connection procedures. Electric shock from wiring can kill. Disconnect input power before working on unit or making terminal strip connections. Nameplate D-179 389 OM-222 Page 12 3-5. Symbols And Definitions Some symbols are found only on CE products. A U0 I1 IP Amperes Amperage Control/ Panel Gas Tungsten Arc Welding (GTAW) Shielded Metal Arc Welding (SMAW) Temperature Do Not Switch While Welding Arc Force (DIG) Percent Output Circuit Breaker Remote Protective Earth (Ground) Positive Negative Input On Off Hertz Direct Current Conventional Load Voltage Line Connection Duty Cycle Three-Phase Transformer Rectifier KVA Work Connection Rated No Load Voltage (Average) U1 Primary Voltage Primary Current I2 Rated Welding Current Degree Of Protection Three-Phase Wire Feeder Electrode Connection Hz U2 X S1 V Volts 3-6. WEEE Label (For Products Sold Within The EU) Do not discard product (where applicable) with general waste. Reuse or recycle Waste Electrical and Electronic Equipment (WEEE) by disposing at a designated collection facility. Contact your local recycling office or your local distributor for further information. OM-222 Page 13 SECTION 4 − INSTALLATION 4-1. Important Information Regarding CE Products (Sold Within The EU) ! This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding. This equipment is built in accordance with EN 60974−1 and is intended to be used only in an occupational environment (where the general public access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person. Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding circuit may not be a major contributor to the EMF. See the Owner’s Manuals for all components of the welding circuit for additional EMF exposure information. The EMF assessment on this equipment was conducted at 0.5 meter. At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values. 4-2. Serial Number And Rating Label Location The serial number and rating information for the power source is located on the front or the rear of the machine. Use the rating labels to determine input power requirements and/or rated output. For future reference, write serial number in space provided on back cover of this manual. 4-3. Specifications Model Rated Welding Output Amp Range DC Maximum OpenCircuit Voltage DC IP Rating 300 Amp 300 A @ 32 Volts DC, 60% Duty Cycle 15 − 395 68 (70) 450 Amp 450 A @ 38 Volts DC, 60% Duty Cycle 20 − 590 650 Amp 650 A @ 44 Volts DC, 60% Duty Cycle 50 − 850 200 V 230 V 380 V 400 V 440 V 460 V 575 V KVA KW 21M 70 4.0* 61 3.6* 35 1.1* 33 1.1* 31 1.0* 31 3.1* 25 1.5* 24.5 1.3* 13.8 0.67* 71 (70) 21M 102 3.5* 89 3.1* 54 1.5* 51 1.4* 47 1.2* 45 1.5* 36 1.2* 35.5 1.2* 23.3 0.51* 71 (70) 21M −− 124 5.2* 75 1.7* 71 1.6* 65 1.5* 62 2.6* 50 2.1* 49.4 2.1* 36 0.58* *While idling ( ) Indicates specification differences for CE models OM-222 Page 14 Amperes Input at Rated Load Output, 50 or 60 Hz, Three-Phase 4-4. Duty Cycle And Overheating Duty Cycle is percentage of 10 minutes that unit can weld at rated load without overheating. If unit overheats, thermostat(s) opens, output stops, and cooling fan runs. Wait fifteen minutes for unit to cool. Reduce amperage or duty cycle before welding. NOTICE − Exceeding duty cycle can damage unit and void warranty. Example: 60% Duty Cycle = 6 Minutes Welding Overheating 4 Minutes Resting A 0 15 Minutes OR Reduce Duty Cycle duty1 4/95 / Ref. 168 919 OM-222 Page 15 4-5. Volt-Ampere Curves A. 300 Amp Model Volt-ampere curves show minimum and maximum voltage and amperage output capabilities of unit. Curves of other settings fall between curves shown. B. 450 Amp Model C. 650 Amp Model va_curve1 − 4/95 − 171 221 / 171 222 / 171 223 OM-222 Page 16 4-6. Selecting A Location 1 2 Lifting Eye Lifting Forks Use lifting eye or lifting forks to move unit. If using lifting forks, extend forks beyond opposite side of unit. Movement 3 Line Disconnect Device Locate unit near correct input power supply. ! 1 Special installation may be required where gasoline or volatile liquids are present − see NEC Article 511 or CEC Section 20. OR 2 Location And Airflow 3 18 in. (460 mm) 18 in. (460 mm) OM-222 Page 17 4-7. Dimensions And Weights Dimensions 300 Amp Models 450 Amp Models 650 Amp Models A 30 in. (762 mm) including lift eye 30 in. (762 mm) including lift eye 30 in. (762 mm) including lift eye B 23 in. (585 mm) 23 in. (585 mm) 23 in. (585 mm) C 30-1/2 in. (775 mm) including strain relief 38 in. (966 mm) including strain relief 38 in. (966 mm) including strain relief D 27-1/2 in. (699 mm) 35 in. (889 mm) 35 in. (889 mm) E 3/4 in. (19 mm) 1-1/4 in. (32 mm) 1-1/4 in. (32 mm) F 21-1/8 in. (537 mm) 21-1/8 in. (537 mm) 21-1/8 in. (537 mm) G 1-1/8 in. (29 mm) 1-1/8 in. (29 mm) 1-1/8 in. (29 mm) H 7/16 in. (11 mm) Dia 7/16 in. (11 mm) Dia 7/16 in. (11 mm) Dia 352 lb (160 kg) 404 lb (183 kg) Weight 505 lb (229 kg) F G H 4 Holes A D B C E Front 800 453-A / 801 530 OM-222 Page 18 4-8. Tipping ! Do not move or operate unit where it could tip. 4-9. 115 VAC Receptacle And Supplementary Protectors 3 ! Turn Off power before connecting to receptacle. 1 115 V 15 A AC Receptacle RC9 Power is shared between RC9 and Remote 14 receptacle RC8 (see Section 4-14). 2 2 3 Supplementary Protector CB1 Supplementary Protector CB2 CB1 protects the 115 volts ac portion of RC8 and RC9 from overload. 1 CB2 protects the 24 volts ac portion of RC8. Press button to reset protector. Ref. 800 101-D 4-10. Weld Output Terminals ! Turn Off power before connecting to weld output receptacle. 1 2 Electrode Output Terminal Work Output Terminal Select cables according to Section 4-11. ! Do not use worn, damaged, undersized, or poorly spliced cables. Connect weld cables according to Section 4-12. 1 2 Ref. 800 101-D OM-222 Page 19 4-11. Selecting Cable Sizes* NOTICE − The Total Cable Length in Weld Circuit (see table below) is the combined length of both weld cables. For example, if the power source is 100 ft (30 m) from the workpiece, the total cable length in the weld circuit is 200 ft (2 cables x 100 ft). Use the 200 ft (60 m) column to determine cable size. Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit Not Exceeding*** Weld Output Terminals ! Turn off power before connecting to weld output terminals. ! Do not use worn, damaged, undersized, or poorly spliced cables. 100 ft (30 m) or Less 200 ft (60 m) 250 ft (70 m) 300 ft (90 m) 350 ft 400 ft (105 m) (120 m) 10 − 60% Duty Cycle 60 − 100% Duty Cycle AWG (mm2) AWG (mm2) 100 4 (20) 4 (20) 4 (20) 3 (30) 2 (35) 1 (50) 1/0 (60) 1/0 (60) 150 3 (30) 3 (30) 2 (35) 1 (50) 1/0 (60) 2/0 (70) 3/0 (95) 3/0 (95) 200 3 (30) 2 (35) 1 (50) 1/0 (60) 2/0 (70) 3/0 (95) 4/0 (120) 4/0 (120) 250 2 (35) 1 (50) 1/0 (60) 2/0 (70) 3/0 (95) 4/0 (120) 2 ea. 2/0 (2x70) 2 ea. 2/0 (2x70) 300 1 (50) 1/0 (60) 2/0 (70) 3/0 (95) 4/0 (120) 2 ea. 2/0 (2x70) 2 ea. 3/0 (2x95) 2 ea. 3/0 (2x95) 350 1/0 (60) 2/0 (70) 3/0 (95) 4/0 (120) 2 ea. 2/0 (2x70) 2 ea. 3/0 (2x95) 2 ea. 3/0 (2x95) 2 ea. 4/0 (2x120) 400 1/0 (60) 2/0 (70) 3/0 (95) 4/0 (120) 2 ea. 2/0 (2x70) 2 ea. 3/0 (2x95) 2 ea. 4/0 (2x120) 2 ea. 4/0 (2x120) 500 2/0 (70) 3/0 (95) 4/0 (120) 2 ea. 2/0 (2x70) 2 ea. 3/0 (2x95) 2 ea. 4/0 (2x120) 3 ea. 3/0 (3x95) 3 ea. 3/0 (3x95) 600 3/0 (95) 4/0 (120) 2 ea. 2/0 (2x70) 2 ea. 3/0 (2x95) 2 ea. 4/0 (2x120) 3 ea. 3/0 (3x95) 3 ea. 4/0 (3x120) 3 ea. 4/0 (3x120) 700 4/0 (120) 2 ea. 2/0 (2x70) 2 ea. 3/0 (2x95) 2 ea. 4/0 (2x120) 3 ea. 3/0 (3x95) 3 ea. 4/0 (3x120) 3 ea. 4/0 (3x120) 4 ea. 4/0 (4x120) 800 4/0 (120) 2 ea. 2/0 (2x70) 2 ea. 3/0 (2x95) 2 ea. 4/0 (2x120) 3 ea. 4/0 (3x120) 3 ea. 4/0 (3x120) 4 ea. 4/0 (4x120) 4 ea. 4/0 (4x120) Welding Amperes * This 150 ft (45 m) 10 − 100% Duty Cycle AWG (mm2) chart is a general guideline and may not suit all applications. If cable overheats, use next size larger cable. **Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. ( ) = mm2 for metric use ***For distances longer than those shown in this guide, call a factory applications rep. at 920-735-4505 (Miller) or 1-800-332-3281 (Hobart) Ref. S-0007-G 2009−08 OM-222 Page 20 4-12. Connecting Weld Output Cables 4 1 Do not place anything between weld cable terminal and copper bar. 2 Tools Needed: 3 3/4 in (19 mm) 803 778-B Correct Installation ! Turn off power before connecting to weld output terminals. ! Failure to properly connect weld cables may cause excessive heat and start a fire, or damage your machine. Incorrect Installation 1 Weld Output Terminal 2 Supplied Weld Output Terminal Nut 3 Weld Cable Terminal 4 Copper Bar Remove supplied nut from weld output terminal. Slide weld cable terminal onto weld output terminal and secure with nut so that weld cable terminal is tight against copper bar. Do not place anything between weld cable terminal and copper bar. Make sure that the surfaces of the weld cable terminal and copper bar are clean. 4-13. Remote 14 Receptacle Information Socket 24 VOLTS AC REMOTE OUTPUT CONTROL 115 VOLTS AC GND REMOTE POWER ON/OFF REMOTE VOLTAGE SENSING Information A 24 volts AC. Protected by supplementary protector CB2. B Contact closure to A completes 24 volts AC contactor control circuit. C Command reference; 0 to +10 volts DC. D Remote control circuit common. E 0 to +10 volts DC input command signal from remote control. F Current feedback; 1 volt per 100 amperes. H Voltage feedback; 1 volt per 10 arc volts. I 115 volts, 15 amperes, 60 Hz AC. Protected by supplementary protector CB1. J Contact closure to I completes 115 volts AC contactor control circuit. K Chassis common. G Circuit common for 24 and 115 volts AC circuits. * * To remote On/Off switch. * Voltage sensing signal from Negative (-) weld output terminal. * Voltage sensing signal from Positive (+) weld output terminal. * Not Used OM-222 Page 21 4-14. Connecting Remote Control 1 Remote 14 Receptacle RC8 Connect remote control to RC8. 1 A B K J I H C L N D M G E F OR OR Ref. 800 101-D / 141 127-D OM-222 Page 22 4-15. Electrical Service Guide Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommendations are for a dedicated branch circuit sized for the rated output and duty cycle of the welding power source. 60 Hertz Models 300 Amp Model 450 Amp Model 650 Amp Model Input Voltage (V) 200 230 460 575 200 230 460 575 230 460 575 Input Amperes (A) At Rated Output 70 61 31 25 102 89 45 36 124 62 50 Time-Delay Fuses 2 80 70 35 30 125 110 50 45 150 70 60 Normal Operating Fuses 3 110 90 45 35 150 125 70 50 175 90 70 6 8 10 12 4 4 8 10 3 8 8 149 (45) 131 (40) 356 (108) 342 (104) 136 (41) 180 (55) 319 (97) 335 (102) 144 (44) 210 (64) 328 (100) 6 8 10 12 6 6 8 10 6 8 8 Max Recommended Standard Fuse Rating In Amperes 1 Min Input Conductor Size In AWG 4 Max Recommended Input Conductor Length In Feet (Meters) Min Grounding Conductor Size In AWG 4 Reference: 2008 National Electrical Code (NEC) (including article 630) 1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse. 2 “Time-Delay” fuses are UL class “RK5” . See UL 248. 3 “Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amps), and UL class “H” ( 65 amps and above). 4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table 310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements. Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommendations are for a dedicated branch circuit sized for the rated output and duty cycle of the welding power source. 300 Amp Model 50 Hertz Models 450 Amp Model 650 Amp Model Input Voltage (V) 380 400 440 380 400 440 380 400 440 Input Amperes (A) At Rated Output 35 33 31 54 51 47 75 71 65 Time-Delay Fuses 2 40 40 35 60 60 50 90 80 80 Normal Operating Fuses 3 60 50 50 80 80 70 125 110 100 10 10 10 8 8 8 6 6 6 243 (74) 269 (82) 326 (99) 218 (66) 241 (73) 292 (89) 219 (67) 242 (74) 293 (89) 10 10 10 8 8 8 6 6 8 Max Recommended Standard Fuse Rating In Amperes 1 Min Input Conductor Size In AWG 4 Max Recommended Input Conductor Length In Feet (Meters) Min Grounding Conductor Size In AWG 4 Reference: 2008 National Electrical Code (NEC) (including article 630) 1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse. 2 “Time-Delay” fuses are UL class “RK5” . See UL 248. 3 “Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amps), and UL class “H” ( 65 amps and above). 4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table 310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements. OM-222 Page 23 4-16. Placing Jumper Links ! Disconnect and lockout/tagout input power before installing or moving jumper links. Check input voltage available at site. 1 Jumper Link Label Check label − only one is on unit. 2 Jumper Links Move jumper links to match input voltage. Close and secure access door, or go on to Section 4-17. 200 VOLTS 230 VOLTS 460 VOLTS Ref. S-174 976-B 230 VOLTS 460 VOLTS 575 VOLTS Ref. S-174 973-B 1 220 VOLTS 380 VOLTS 400 VOLTS 440 VOLTS (FACTORY OPTION) Ref. S-174 975-B 2 Tools Needed: 3/8 in 3/8 in Do not overtighten jumper link nuts. Ref. 800 103-A OM-222 Page 24 4-17. Connecting Input Power 3 = GND/PE Earth Ground 9 8 ! Installation must meet all National and Local Codes − have only qualified persons make this installation. ! Disconnect and lockout/tagout input power before connecting input conductors from unit. ! Make input power connections to the welding power source first. ! Always connect green or green/yellow conductor to supply grounding terminal first, and never to a line terminal. See rating label on unit and check input voltage available at site. 11 1 10 Input Power Conductors (Customer Supplied Cord) Select size and length of conductors using Section 4-15. Conductors must comply with national, state, and local electrical codes. If applicable, use lugs of proper amperage capacity and correct hole size. 2 4 7 Welding Power Source Input Power Connections 2 1 IMPORTANT 6 3 Input Contactor 3 4 5 7 L2 (V) L3 (W) 6 7 5 4 Machine Grounding Terminal Green Or Green/Yellow Grounding Conductor Reed Switch (Ground Current Sensor) (Optional) Connect green or green/yellow grounding conductor to welding power source grounding terminal first. If unit is equipped with optional ground current sensor, route grounding conductor through reed switch two times and connect to grounding terminal. L1 (U) 4 Strain Relief Route conductors (cord) through strain relief and tighten screws. 3 = GND/ PE Earth Ground Welding Power Source Line Terminals Input Conductors L1 (U), L2 (V) And L3 (W) Connect input conductors L1 (U), L2 (V) and L3 (W) to welding power source line terminals. Close and secure access door on welding power source. Disconnect Device Input Power Connections 8 9 Disconnect Device (switch shown in OFF position) Disconnect Device (Supply) Grounding Terminal Connect green or green/yellow grounding conductor to disconnect device grounding terminal first. 10 Disconnect Device Line Terminals Tools Needed: 3/8 in 3/8 in Connect input conductors L1 (U), L2 (V) And L3 (W) to disconnect device line terminals. 11 Over-Current Protection Select type and size of over-current protection using Section 4-15 (fused disconnect switch shown). Close and secure door on line disconnect device. Remove lockout/tagout device, and place switch in the On position. 800 103-C / Ref. 801 116-A OM-222 Page 25 SECTION 5 − OPERATION 5-1. Controls (Non CE Models) 300 Amp Model Shown 1 2 9 3 5 4 8 7 6 Ref. 165 596-D short arc length without sticking the electrode. 1 Polarity Selector Switch (Optional On 50 Hz Models) To change polarity on models not equipped with a Polarity Selector switch, reverse work and electrode cables at the weld output terminals (see Section 4-11). ! Turn Off Power before reversing cables. 2 Arc Force (Dig) Control Control increases SMAW short-circuit amperage which allows the operator to use a very OM-222 Page 26 Set control at 0 for normal welding amperage. Turn clockwise to increase short-circuit amperage. 3 Hot Start Switch Turn switch On for SMAW and Off for GTAW welding. 4 5 6 7 Amperage Adjustment Control Digital Meters (Optional) Power Switch With Indicator Light High Temperature Shutdown Light 8 Remote Amperage Control Switch For front panel control, place switch in Panel position. For remote control, place switch in Remote position, and connect remote device (see Section 4-14). 9 Output Switch (Contactor) For front panel control of output, place switch in Panel position. For remote control of output, place switch in Remote position, and connect remote device (see Section 4-14). ! Turn Off power before connecting remote device. 5-2. Controls (CE Models) 300 Amp Model Shown 2 1 9 3 4 8 5 7 6 Ref. 173 450-B 1 Polarity Selector Switch (Optional On 50 Hz Models) To change polarity on models not equipped with a Polarity Selector switch, reverse work and electrode cables at the weld output terminals (see Section 4-11). ! Turn Off Power before reversing cables. 2 Arc Force (Dig) Control Control increases SMAW short-circuit amperage which allows the operator to use a very short arc length without sticking the electrode. 8 Set control at 0 for normal welding amperage. Turn clockwise to increase short-circuit amperage. For front panel control, place switch in Panel position. For remote control, place switch in Remote position, and connect remote device (see Section 4-14). 3 Hot Start Switch Turn switch On for SMAW and Off for GTAW welding. 9 Remote Amperage Control Switch Output Switch (Contactor) 4 Amperage Adjustment Control 5 Digital Meters (Optional) For front panel control of output, place switch in Panel position. For remote control of output, place switch in Remote position, and connect remote device (see Section 4-14). 6 Power Switch With Indicator Light 7 High Temperature Shutdown Light ! Turn Off power before connecting remote device. OM-222 Page 27 SECTION 6 − MAINTENANCE AND TROUBLESHOOTING 6-1. Routine Maintenance ! Disconnect power before maintaining. Maintain more often during severe conditions. = Check = Change = Clean * To be done by Factory Authorized Service Agent Δ = Repair = Replace Every 3 Months Labels Weld Terminals Every 3 Months Δ Cables And Cords Every 6 Months :During heavy service, clean monthly. 6-2. Fuse F1 1 ! Turn Off power before opening rear access door. 1 Fuse F1 (See Parts List For Rating) Fuse F1 protects control transformer from overload. If F1 opens, weld output and fan motor stops. Replace F1. Close and secure access door. Tools Needed: 3/8 in OM-222 Page 28 Ref. 800 101-C 6-3. Troubleshooting Trouble No weld output; unit completely inoperative. Remedy Place line disconnect switch in On position (see Section 4-17). Check fuse F1, and replace if necessary (see Section 6-2). Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section 4-17). Check for proper input power connections (see Section 4-17). Check for proper jumper link position (see Section 4-16). No weld output; Power switch pilot light on; fan on. If using remote control, place Output (Contactor) switch in Remote 14 position, and connect remote control (see Section 4-14). If remote is not being used, place switch in On position. Check, repair, or replace remote control. Unit overheated. Allow unit to cool with fan On (see Section 4-4). Have Factory Authorized Service Agent check control board PC1. No weld output; Power switch pilot light Check for proper input power connections (see Section 4-17). on; fan off. Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section 4-17). Have Factory Authorized Service Agent check SCR’s. Unit provides only maximum or minimum weld output. Have Factory Authorized Service Agent check control board PC1 and hall device HD1. Erratic or improper weld output. Use proper size and type of weld cable (see Section 4-10 and 4-11). Clean and tighten all weld connections. Check position of Polarity selector switch (see Section 5-1). Have Factory Authorized Service Agent check control board PC1 and hall device HD1. No 115 volts AC output at duplex receptacle, Remote 14 receptacle. Reset supplementary protector CB1 (see Section 4-9). No 24 volts AC output at Remote 14 receptacle. Reset supplementary protector CB2 (see Section 4-9). Fan not operating. Fan only runs when cooling is necessary. Check for and remove anything blocking fan movement. Have Factory Authorized Service Agent check fan motor. OM-222 Page 29 SECTION 7 − ELECTRICAL DIAGRAM Figure 7-1. Circuit Diagram OM-222 Page 30 218 518-C OM-222 Page 31 21 23 8 29 - (Fig 8-3 & 4) 22 1 28 - (Fig 8-2) 27 3 2 24 4 5 6 7 11 10 4 13 15 12 9 14 16 17 3 19 not available unless listed. 20 Hardware is common and 22 18 - (Fig 8-5) SECTION 8 − PARTS LIST Figure 8-1. Main Assembly (452 Model Illustrated) OM-222 Page 32 800 875-G Item No. Diagram marking Part No. Description Quantity Model 302 452 652 402 602 852 Figure 8-1. Main Assembly . . . 1 . . . . . . . . . . . . +179 430 . . . 1 . . . . . . . . . . . . +179 432 . . . 2 . . . . . . . . . . . . . 179 429 . . . 2 . . . . . . . . . . . . . 179 431 . . . 3 . . . . . . . . . . . . . 164 699 . . . 3 . . . . . . . . . . . . . 164 700 . . . 4 . . . . . . . . . . . . . 162 816 . . . 5 . . . . . . . . . . . . . 162 820 . . . 6 . . . . . . . . . . . . . 162 830 . . . 7 . . . . . . . . . . . . . 177 279 . . . 8 . . . . . . . . . . . . . 604 536 . . . 9 . . . . . . . . . . . . . 173 605 . . . 10 . . . . HD1 . . . . 168 829 . . . . . . . . . PLG14 . . 115 094 . . . 11 . . . . . Z1 . . . . 165 612 . . . 11 . . . . . Z1 . . . . 165 613 . . . 11 . . . . . Z1 . . . . 180 064 . . . . . . . . . . . . . . . . . . . 164 717 . . . 12 . . . C21-23 . . 163 906 . . . 13 . . . . . T2 . . . . 159 042 . . . 13 . . . . . T2 . . . . 159 041 . . . 13 . . . . . T2 . . . . 159 043 . . . 14 . . . . TE1 . . . . 159 244 . . . 15 . . . . . . . . . . . . . 601 835 . . . 16 . . . . . . . . . . . . . 038 887 . . . . . . . . . . . . . . . . . . . 010 913 . . . . . . . . . . . . . . . . . . . 601 835 . . . . . . . . . . . . . . . . . . . 038 618 . . . 17 . . . . . . . . . . . . . 159 034 . . . 18 . . . . . . . . . . . . . . Fig 8-5 . . . 19 . . . . . F1 . . . *156 065 . . . 20 . . . . . W . . . . . 160 760 . . . 20 . . . . . W . . . . . 160 793 . . . 20 . . . . . W . . . . . 160 794 . . . 21 . . . . CR4 . . ♦140 750 . . . 22 . . . . . . . . . . . . . 217 136 . . . 22 . . . . . . . . . . . . . 176 254 . . . 23 . . . . . . . . . . . . . 163 533 . . . 23 . . . . . . . . . . . . . 163 359 . . . 24 . . . . . T1 . . . . 218 399 . . . 24 . . . . . T1 . . . . 218 400 . . . 24 . . . . . T1 . . . . 218 402 . . . 24 . . . . . T1 . . . . 218 403 . . . 24 . . . . . T1 . . . . 218 405 . . . 24 . . . . . T1 . . . . 218 401 . . . 24 . . . . . T1 . . . . 218 404 . . . 24 . . . . . T1 . . . . 218 406 . . PANEL, side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . PANEL, side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 2 . . COVER, top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . COVER, top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . BAFFLE, air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 2 . . BAFFLE, air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . CHANNEL, upright . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 . . . 4 . . . 4 . . BAR, mtg lift eye . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 2 . . . 2 . . LIFT EYE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . 1 . . GASKET, lift eye . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . 1 . . SCREW, .312-18 x 1.75 hexhd-pln gr 5 . . . . . . . . . . . . . . . . . . . 2 . . . 2 . . . 2 . . BRACKET, mtg LEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . 1 . . TRANSDUCER, current 1000A module . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . 1 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . 1 . . STABILIZER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . STABILIZER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . STABILIZER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . BUS BAR, stabilizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . CAPACITOR, 60 and 50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 . . . 3 . . . 3 . . TRANSFORMER, control 50VA 24V 230/460/575 (60Hz) . . . 1 . . . 1 . . . 1 . . TRANSFORMER, control 50VA 24V 200/230/460 (60Hz) . . . . . . . . . 1 . . TRANSFORMER, control 50VA 24V (50Hz) . . . . . . . . . . . . . . . 1 . . . 1 . . . 1 . . PRIMARY BOX, (includes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . 1 . . . . NUT, 10-32 brs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 . . 24 . . 24 . . . . STUD, pri bd brs 10-32 x 1.375 . . . . . . . . . . . . . . . . . . . . . . . 24 . . 24 . . 24 . . WASHER, flat .218 ID brs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 . . 24 . . 24 . . NUT, 10-32 brs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 . . 24 . . 24 . . LINK, jumper term bd pri . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 . . . 8 . . . 8 . . HOLDER, fuse mintr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . 1 . . PANEL, rear w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . 1 . . FUSE, crtg .5A 600V time delay . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . 1 . . CONTACTOR, def prp 40A 3P 24VAC . . . . . . . . . . . . . . . . . . . . 1 . . CONTACTOR, def prp 60A 3P 24VAC . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . CONTACTOR, def prp 75A 3P 24V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . SWITCH, reed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . 1 . . LABEL, warning electric shock . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 2 . . . 2 . . LABEL, general precautionary wordless,intl (CE models only) 2 . . . 2 . . . 2 . . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . TRANSFORMER, pwr main 200/230/460 . . . . . . . . . . . . . . . . . 1 . . TRANSFORMER, pwr main 230/460/575 . . . . . . . . . . . . . . . . . 1 . . TRANSFORMER, pwr main 200/230/460 . . . . . . . . . . . . . . . . . . . . . . . 1 . . TRANSFORMER, pwr main 230/460/575 . . . . . . . . . . . . . . . . . . . . . . . 1 . . TRANSFORMER, pwr main 230/460/575 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . TRANSFORMER, pwr main 380/400/440 . . . . . . . . . . . . . . . . . 1 . . TRANSFORMER, pwr main 380/400/440 . . . . . . . . . . . . . . . . . . . . . . . 1 . . TRANSFORMER, pwr main 380/400/440 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 OM-222 Page 33 Item No. Diagram marking Part No. Description Quantity Model 302 452 652 402 602 852 Figure 8-1. Main Assembly (Continued) . . . . . . . . . TP1,2 . . . 175 405 . . . . . . . . . TP4,5 . . . 168 891 . . . . . . . . . PLG13 . . 218 413 . . . . . . . . . RC13 . . . 218 408 . . . 27 . . . . . . . . . . . . . 161 294 . . . 28 . . . . . . . . . . . . . . Fig 8-2 . . . 29 . . . . SR1 . . . . 175 070 . . . 29 . . . . SR1 . . . . 192 672 . . . 29 . . . . SR1 . . . . 192 671 .. .. .. .. .. .. .. .. .. THERMOSTAT, NC (Included w/T1) . . . . . . . . . . . . . . . . . . . . . . 2 . . . 2 . . . THERMOSTAT, NC (Included w/T1) . . . . . . . . . . . . . . . . . . . . . . 2 . . . 2 . . . HOUSING, plug pin/skt (service kit) . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . HOUSING, plug pin/skt (service kit) . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . BRACKET, mtg rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 2 . . . PANEL, front w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . RECTIFIER, si diode (Fig 8-3) . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 RECTIFIER, SCR main (Fig 8-4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 RECTIFIER, SCR main (Fig 8-4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 1 1 2 1 1 +When ordering a component originally displaying a precautionary label, the label should also be ordered. *Recommended Spare Parts. ♦Part of Option 195 048 Ground Current Sensor To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested Replacement Parts. Model and serial number required when ordering parts from your local distributor. OM-222 Page 34 1 5 6 8 7 2 3 9 32 33 10 4 11 34 36 24 10 33 31 23 22 20 21 24 35 37 14 13 19 18 30 29 17 28 27 25 800 876-G 26 Figure 8-2. Panel, Front w/Components (452 Model Illustrated) Item No. Diagram marking Part No. Description Quantity Model 302 452 652 402 602 852 Figure 8-2. Panel, Front w/Components (Fig 8-1 Item 28) . . . 1 . . . . . S5 . . ♦169 331 . . . 1 . . . . . S5 . . ♦169 332 . . . 2 . . . . PC1 . . . . 207 042 . . . 2 . . . . PC1 . . . . 207 044 . . . 2 . . . . PC1 . . . . 207 047 . . . 2 . . . . PC1 . . . . 231 169 . . . 2 . . . . PC1 . . . . 231 165 . . . 2 . . . . PC1 . . . . 231 163 . . . . . . . . . PLG1 . . . 158 720 . . . . . . . . . PLG3 . . . 169 240 . . . . . . . . . PLG5 . . . 152 249 . . . 3 . . . . CR3 . . . . 052 964 . . . 4 . . . . CR5 . . . . 006 393 . . . 5 . . . CB1,2 . . . 093 995 . . . 6 . . . . RC9 . . . . 604 176 . . . 7 . . . . . . . . . . . . . 203 778 . . . . . . . . . . RC8 . . . . 143 976 . . . . . . . C3,6,13,14 . 097 749 . . . 8 . . . . . . . . . . . . . . 204143 . . . 9 . . . . POS . . . 181 245 . . . 10 . . . . C4,5 . . . 230 729 . . . 11 . . . . . . . . . . . . . 161 303 . . . 13 . . . . NEG . . . 181 246 . . SWITCH, mode polarity (single deck) . . . . . . . . . . . . . . . . . . . . . 1 . . SWITCH, mode polarity (double deck) . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . CIRCUIT CARD, control (60Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . CIRCUIT CARD, control (60Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . CIRCUIT CARD, control (60Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CIRCUIT CARD, control (50HZ) . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . CIRCUIT CARD, control (50HZ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . CIRCUIT CARD, control (50HZ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONNECTOR & SOCKETS, (see Figs 8-3 & 8-4) . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . . . RELAY, encl 24VDC DPDT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . . . RELAY, encl 24VAC DPDT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . . . SUPPLEMENTARY PROTECTOR, man reset 1P 15A 250VAC2 . . . 2 . . . . . RECEPTACLE, str dx grd 2P3W 15A 125V . . . . . . . . . . . . . . . . 1 . . . 1 . . . . . CONNECTOR/CAPACITOR, w/leads (includes) . . . . . . . . . . . . 1 . . . 1 . . . . . . . RCPT w/ SCKTS (service kit) . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . . . . . CAPACITOR, cer disc .05 UF 500 VDC strip . . . . . . . . . . . . 4 . . . 4 . . . . . PANEL, front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . . . TERMINAL, pwr output red . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . . . CAPACITOR, cer disc .1uf 500VDC w/terms . . . . . . . . . . . . . . 2 . . . 2 . . . . . SPRING, cprsn .600 OD x .072 wire x 1.500 lg . . . . . . . . . . . . 3 . . . 3 . . . . . TERMINAL, pwr output black . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . 1 1 1 1 1 1 1 2 1 1 1 4 1 1 2 3 1 OM-222 Page 35 Item No. Diagram marking Part No. Description Quantity Model 302 452 652 402 602 852 Figure 8-2. Panel, Front w/Components (Fig 8-1 Item 28) (Continued) . . . 14 . . . . . . . . . . . . . 206 785 . . PLATE, control lower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 . . . . . . . . . . . . . 217 865 . . LABEL, warning electric shock and reduced air . . . . . . . . . . . . . . . 17 . . . . . . . . . . . . . 179 563 . . LABEL, electric shock/reduce air flow (CE models only) . . . . . . . . . . 18 . . . . . . . . . . . . +172 587 . . COVER, stud output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 . . . . . . . . . . . . . 160 935 . . CLIP, spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 . . . . . . . . . . . . . 601 835 . . NUT, 10-32 brs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 010 913 . . WASHER, flat .218 ID x .460 OD x .031thk brs . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . 159 863 . . ELECTRONICS BOX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PLG6 . . . 168 847 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RC6 . . . . 168 845 . . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PLG7 . . . 152 249 . . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RC7 . . . . 168 846 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 . . . . . . . . . . . . . 038 887 . . STUD, pri bd brs 10-32 x 1.375 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 . . . S1,3,4 . . . 011 609 . . SWITCH, tgl SPDT 15A 125VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 . . . . R1,2 . . . 198 087 . . POTENTIOMETER, CP std slot 1/T 2W 1K ohm . . . . . . . . . . . . . . 25 . . . . . . . . . . . . . . . . . . . . . . . . NAMEPLATE, (order by model and serial number) . . . . . . . . . . . . 26 . . . . . S2 . . . . 159 039 . . SWITCH, rocker SPDT 15A 125VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PLG2 . . . 185 626 . . CONNECTOR, body 56 series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 . . . . PL2 . . . . 159 522 . . LED, yellow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 . . . . . . . . . . . . . 159 036 . . LENS, LED clear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 . . . . . . . . . . . . . 171 007 . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 . . . . . . . . . . . . . 193 919 . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 . . . . . . . . . . . ♦148 956 . . HANDLE, switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 . . . . SN1 . . . . 234 081 . . SNUBBER, assy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ♦♦♦300 498 . . DIGITAL METER KIT, (includes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PC2 . . . . 231 149 . . . . CIRCUIT CARD, digital meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PLG4,11 . . 148 439 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PLG10 . . 153 501 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192 174 . . . . STAND-OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . 010 381 . . . . CONNECTOR, rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 . . . . . . . . . . . . . 162 815 . . . . PANEL, front upper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 . . . . . . . . . . . . . 005 107 . . . . BOLT, crg stl .250-20 x .750 Gr 5 pld . . . . . . . . . . . . . . . . . . . . . . . . 36 . . . . . . . . . . . . . 228 672 . . . . LABEL, weld cable lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 . . . . . . . . . . . . . 228 672 . . . . LABEL, caution output terminal connection . . . . . . . . . . . . . . . . 1 1 1 1 3 2 1 1 1 1 1 1 1 3 2 1 1 1 1 1 1 1 1 1 1 1 2 1 4 2 1 4 2 1 ... 1 ... 1 ... 1 ... 1 ... 3 ... 2 ... 1 ... 1 ... 1 ... 1 ... 1 ... 1 ... 1 ... 3 ... 2 ... 1 ... 1 ... 1 ... 1 ... 1 ... 1 ... 1 ... 1 ... 1 ... 1 ... 1 ... 2 ... 1 ... 4 ... 2 ... 1 ... 4 ... 2 ... 1 ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... 1 1 1 1 3 2 1 1 1 1 1 1 1 3 2 1 1 1 1 1 1 1 1 1 1 1 2 1 4 2 1 4 2 1 ♦Standard w/60 Hz/Optional w/50 Hz +When ordering a component originally displaying a precautionary label, the label should also be ordered. ♦♦♦Optional To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested Replacement Parts. Model and serial number required when ordering parts from your local distributor. OM-222 Page 36 Item No. Diagram marking Part No. SR1 175 070 . . . 1 . . . . C7-12 . . . . ... 2 ............... ... 3 ............... ... 4 ............... . . . 5 . . . . . TP3 . . . . . . . . 6 . . . . . TP6 . . . . . . . . 7 . . . SCR1-6 . . . . . . . . . . . . . PLG1 . . . . ... 8 ............... Figure 8-3. Rectifier, Si Diode (302 Model) (Fig 8-1 Item 29) 048 420 177 316 177 317 166 667 185 679 206 083 161 668 158 720 188 692 .. .. .. .. .. .. .. .. .. 3 1 Quantity Description CAPACITOR, cer disc .01uf 1000VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . HEAT SINK, rect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HEAT SINK, rect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CLAMP, thyristor rect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . THERMOSTAT, NC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . THERMOSTAT, NC open 125F close 105F flange horizontal . . . . . . . . . THYRISTOR, SCR 300A 300V hockey puck . . . . . . . . . . . . . . . . . . . . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CLAMP, thyristor rectifier 4.250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3 2 3 1 1 6 1 3 4 5 2 6 7 2 3 1 ST-800 697-C 8 Figure 8-3. Rectifier, Si Diode SR1 (302 Model) 5 4 Hardware is common and not available unless listed. 6 802 351 Figure 8-4. Rectifier, SCR Main SR1 (452 & 652 Model) Item No. Diagram marking SR1 Part No. Description Figure 8-4. Rectifier, SCR Main (452 & 652 Model) (Fig 8-1 Item 29) Quantity 192 672 192 671 . . . 1 . . . . C7-12 . . . . 048 420 . . CAPACITOR, cer disc .01uf 1000VDC . . . . . . . . . . . . . . . . . . . . . . . 6 . . . . 6 . . . 2 . . . . . . . . . . . . . . . 191 989 . . BAR, mtg rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2 . . . 3 . . . . . . . . . . . . . . . 188 691 . . CLAMP, thyristor rectifier 5.375 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 . . . . 3 . . . 4 . . . . . . . . . . . . . . . 188 839 . . HEAT SINK, rectifier snowflake .800 . . . . . . . . . . . . . . . . . . . . . . . . 12 . . 12 . . . 5 . . . SCR1-6 . . . 161 668 . . THYRISTOR, SCR 300A 300V hockey puck . . . . . . . . . . . . . . . . . . 6 . . . 5 . . . SCR1-6 . . . 148 091 . . THYRISTOR, SCR 865A 300V hockey puck . . . . . . . . . . . . . . . . . . . . . . . . 6 . . . 6 . . . . . . . . . . . . . . . 166 667 . . CLAMP, spring thyristor rectifier 5.500 . . . . . . . . . . . . . . . . . . . . . . . 3 . . . . 3 . . . . . . . . . . PLG1 . . . . 158 720 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . . . . . . . . TP3 . . . . . 192 673 . . THERMOSTAT, rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . . . . . . . . TP6 . . . . . 192 674 . . THERMOSTAT, rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested Replacement Parts. Model and serial number required when ordering parts from your local distributor. OM-222 Page 37 Item No. Diagram marking Part No. Quantity Description Figure 8-5. Panel, Rear w/Components (Fig 8-1 Item 18) ... ... ... ... ... ... ... ... ... ... ... 1 2 3 4 5 6 6 8 9 10 11 . . . . . . . . . . . . . . . 173 283 . . . . . . . . . . . . . . . 180 165 . . . . . . . . . . . . . . . 162 807 . . . . . . . . . . . . . . . 168 343 . . . . . . . . . . . . . . +162 818 . . . . . . . . . . . . . . . 217 733 . . . . . . . . . . . . . . . 179 290 . . . . . . . . . . . . . . . 124 274 . . . . . R3 . . . . . . 097 459 . . . . . FM . . . . . 237 398 . . . . . . . . . . . . . . . 010 467 .. .. .. .. .. .. .. .. .. .. .. CHAMBER, plenum 14 in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BLADE, fan 14 in 3wg 23deg .375 bore CCW . . . . . . . . . . . . . . . . . . . . . . PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HINGE, door primary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DOOR, access primary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LABEL, warning electric shock & input power (EN/FR) . . . . . . . . . . . . . . LABEL, warning electric shock input connection (CE models only) . . . BRACKET, mtg fan motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RESISTOR, WW fxd 375W 20 ohm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MOTOR, 1/12HP 230V 1550RPM 50/60Hz .83A . . . . . . . . . . . . . . . . . . . CONNECTOR, clamp cable 1.250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Hardware is common and 1 1 1 2 1 1 1 1 1 1 1 4 not available unless listed. 5 6 2 1 11 8 10 9 800 707-E Figure 8-5. Panel, Rear w/Components +When ordering a component originally displaying a precautionary label, the label should also be ordered. To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested Replacement Parts. Model and serial number required when ordering parts from your local distributor. OM-222 Page 38 Effective January 1, 2009 (Equipment with a serial number preface of LK or newer) Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. Your distributor also gives you ... Service You always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor. The expertise of the distributor and Miller is there to help you, every step of the way. This limited warranty supersedes all previous Miller warranties and is exclusive with no other guarantees or warranties expressed or implied. LIMITED WARRANTY − Subject to the terms and conditions * Induction Heating Coils and Blankets, Cables, and below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants to Non-Electronic Controls its original retail purchaser that new Miller equipment sold after * APT & SAF Model Plasma Cutting Torches the effective date of this limited warranty is free of defects in * Remote Controls material and workmanship at the time it is shipped by Miller. THIS * Accessory (Kits) WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE * Replacement Parts (No labor) WARRANTIES OF MERCHANTABILITY AND FITNESS. * Spoolmate Spoolguns Within the warranty periods listed below, Miller will repair or * Canvas Covers replace any warranted parts or components that fail due to such defects in material or workmanship. Miller must be notified in writing within thirty (30) days of such defect or failure, at which time Miller will provide instructions on the warranty claim procedures to be followed. Miller shall honor warranty claims on warranted equipment listed below in the event of such a failure within the warranty time periods. All warranty time periods start on the delivery date of the equipment to the original end-user purchaser, and not to exceed one year after the equipment is shipped to a North American distributor or eighteen months after the equipment is shipped to an International distributor. 1. 2. 3. 4. 5. 5 Years Parts — 3 Years Labor * Original main power rectifiers only to include SCRs, diodes, and discrete rectifier modules 3 Years — Parts and Labor * Transformer/Rectifier Power Sources * Plasma Arc Cutting Power Sources * Process Controllers * Semi-Automatic and Automatic Wire Feeders * Inverter Power Sources (Unless Otherwise Stated) * Water Coolant Systems (Integrated) * Intellitig * Engine Driven Welding Generators (NOTE: Engines are warranted separately by the engine manufacturer.) 1 Year — Parts and Labor Unless Specified * Motor Driven Guns (w/exception of Spoolmate Spoolguns) * Positioners and Controllers * Automatic Motion Devices * RFCS Foot Controls * Induction Heating Power Sources, Coolers, and Electronic Controls/Recorders * Water Coolant Systems (Non-Integrated) * Flowgauge and Flowmeter Regulators (No Labor) * HF Units * Grids * Spot Welders * Load Banks * Fume Extractors * Arc Stud Power Sources & Arc Stud Guns * Racks * Running Gear/Trailers * Plasma Cutting Torches (except APT & SAF Models) * Field Options (NOTE: Field options are covered under True Blue® for the remaining warranty period of the product they are installed in, or for a minimum of one year — whichever is greater.) * Bernard-Branded Mig Guns (No Labor) * Weldcraft-Branded TIG Torches (No Labor) * Subarc Wire Drive Assemblies 6 Months — Batteries 90 Days — Parts * MIG Guns and Subarc (SAW) Guns Miller’s True Blue® Limited Warranty shall not apply to: 1. Consumable components; such as contact tips, cutting nozzles, contactors, brushes, slip rings, relays or parts that fail due to normal wear. (Exception: brushes, slip rings, and relays are covered on Bobcat, Trailblazer, and Legend models.) 2. Items furnished by Miller, but manufactured by others, such as engines or trade accessories. These items are covered by the manufacturer’s warranty, if any. Equipment that has been modified by any party other than Miller, or equipment that has been improperly installed, improperly operated or misused based upon industry standards, or equipment which has not had reasonable and necessary maintenance, or equipment which has been used for operation outside of the specifications for the equipment. 3. MILLER PRODUCTS ARE INTENDED FOR PURCHASE AND USE BY COMMERCIAL/INDUSTRIAL USERS AND PERSONS TRAINED AND EXPERIENCED IN THE USE AND MAINTENANCE OF WELDING EQUIPMENT. In the event of a warranty claim covered by this warranty, the exclusive remedies shall be, at Miller’s option: (1) repair; or (2) replacement; or, where authorized in writing by Miller in appropriate cases, (3) the reasonable cost of repair or replacement at an authorized Miller service station; or (4) payment of or credit for the purchase price (less reasonable depreciation based upon actual use) upon return of the goods at customer’s risk and expense. Miller’s option of repair or replacement will be F.O.B., Factory at Appleton, Wisconsin, or F.O.B. at a Miller authorized service facility as determined by Miller. Therefore no compensation or reimbursement for transportation costs of any kind will be allowed. TO THE EXTENT PERMITTED BY LAW, THE REMEDIES PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF PROFIT), WHETHER BASED ON CONTRACT, TORT OR ANY OTHER LEGAL THEORY. ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND ANY IMPLIED WARRANTY, GUARANTY OR REPRESENTATION AS TO PERFORMANCE, AND ANY REMEDY FOR BREACH OF CONTRACT TORT OR ANY OTHER LEGAL THEORY WHICH, BUT FOR THIS PROVISION, MIGHT ARISE BY IMPLICATION, OPERATION OF LAW, CUSTOM OF TRADE OR COURSE OF DEALING, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE, WITH RESPECT TO ANY AND ALL EQUIPMENT FURNISHED BY MILLER IS EXCLUDED AND DISCLAIMED BY MILLER. Some states in the U.S.A. do not allow limitations of how long an implied warranty lasts, or the exclusion of incidental, indirect, special or consequential damages, so the above limitation or exclusion may not apply to you. This warranty provides specific legal rights, and other rights may be available, but may vary from state to state. In Canada, legislation in some provinces provides for certain additional warranties or remedies other than as stated herein, and to the extent that they may not be waived, the limitations and exclusions set out above may not apply. This Limited Warranty provides specific legal rights, and other rights may be available, but may vary from province to province. miller_warr 2009−01 Owner’s Record Please complete and retain with your personal records. Model Name Serial/Style Number Purchase Date (Date which equipment was delivered to original customer.) Distributor Address City State Zip For Service Contact a DISTRIBUTOR or SERVICE AGENCY near you. Always provide Model Name and Serial/Style Number. Contact your Distributor for: Welding Supplies and Consumables Options and Accessories Personal Safety Equipment Service and Repair Miller Electric Mfg. Co. An Illinois Tool Works Company 1635 West Spencer Street Appleton, WI 54914 USA Replacement Parts Training (Schools, Videos, Books) Technical Manuals (Servicing Information and Parts) Circuit Diagrams For International Locations Visit www.MillerWelds.com Welding Process Handbooks To locate a Distributor or Service Agency visit www.millerwelds.com or call 1-800-4-A-Miller Contact the Delivering Carrier to: File a claim for loss or damage during shipment. For assistance in filing or settling claims, contact your distributor and/or equipment manufacturer’s Transportation Department. ORIGINAL INSTRUCTIONS − PRINTED IN USA International Headquarters−USA USA Phone: 920-735-4505 Auto-Attended USA & Canada FAX: 920-735-4134 International FAX: 920-735-4125 © 2009 Miller Electric Mfg. Co. 2009−01
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project