Quad-Core Intel® Xeon® Processor 5300 Series Datasheet September 2007 Order Number: 315569-003 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Intel products are not intended for use in medical, life saving, life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked “reserved” or “undefined.” Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The Quad-Core Intel® Xeon® Processor 5300 Series may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request. Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order. Intel® 64 architecture requires a computer system with a processor, chipset, BIOS, OS, device drivers and applications enabled for Intel® 64. Processor will not operate (including 32-bit operation) without an Intel EM64T-enabled BIOS. Performance will vary depending on your hardware and software configurations. Intel EM64T-enabled OS, BIOS, device drivers and applications may not be available. Check with your vendor for more information. Copies of documents which have an ordering number and are referenced in this document, or other Intel literature may be obtained by calling 1-800-548-4725 or by visiting Intel's website at http://www.intel.com. Intel, Pentium, Intel Xeon, Enhanced Intel SpeedStep Technology, Intel NetBurst and the Intel logo are trademarks of Intel Corporation in the U.S. and other countries. * Other names and brands may be claimed as the property of others. Copyright © 2005-2007, Intel Corporation 2 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Contents 1 Introduction............................................................................................................... 11 1.1 Terminology ..................................................................................................... 13 1.2 State of Data .................................................................................................... 15 1.3 References ....................................................................................................... 15 2 Electrical Specifications ............................................................................................... 17 2.1 Front Side Bus and GTLREF ................................................................................ 17 2.2 Power and Ground Lands.................................................................................... 18 2.3 Decoupling Guidelines ........................................................................................ 18 2.3.1 VCC Decoupling...................................................................................... 18 2.3.2 VTT Decoupling ...................................................................................... 18 2.3.3 Front Side Bus AGTL+ Decoupling ............................................................ 19 2.4 Front Side Bus Clock (BCLK[1:0]) and Processor Clocking ....................................... 19 2.4.1 Front Side Bus Frequency Select Signals (BSEL[2:0]) .................................. 20 2.4.2 PLL Power Supply ................................................................................... 21 2.5 Voltage Identification (VID) ................................................................................ 21 2.6 Reserved, Unused, or Test Signals ....................................................................... 23 2.7 Front Side Bus Signal Groups .............................................................................. 24 2.8 CMOS Asynchronous and Open Drain Asynchronous Signals .................................... 26 2.9 Test Access Port (TAP) Connection....................................................................... 26 2.10 Platform Environmental Control Interface (PECI) DC Specifications........................... 26 2.10.1 DC Characteristics .................................................................................. 26 2.10.2 Input Device Hysteresis .......................................................................... 27 2.11 Mixing Processors.............................................................................................. 27 2.12 Absolute Maximum and Minimum Ratings ............................................................. 28 2.13 Processor DC Specifications ................................................................................ 29 2.13.1 Flexible Motherboard Guidelines (FMB) ...................................................... 29 2.13.2 VCC Overshoot Specification .................................................................... 42 2.13.3 Die Voltage Validation ............................................................................. 43 2.14 AGTL+ FSB Specifications................................................................................... 43 3 Mechanical Specifications............................................................................................. 47 3.1 Package Mechanical Drawings ............................................................................. 47 3.2 Processor Component Keepout Zones................................................................... 51 3.3 Package Loading Specifications ........................................................................... 51 3.4 Package Handling Guidelines............................................................................... 52 3.5 Package Insertion Specifications.......................................................................... 52 3.6 Processor Mass Specifications ............................................................................. 52 3.7 Processor Materials............................................................................................ 52 3.8 Processor Markings............................................................................................ 53 3.9 Processor Land Coordinates ................................................................................ 53 4 Land Listing ............................................................................................................... 57 4.1 Quad-Core Intel® Xeon® Processor 5300 Series Pin Assignments ........................... 57 4.1.1 Land Listing by Land Name ...................................................................... 57 4.1.2 Land Listing by Land Number ................................................................... 69 5 Signal Definitions ....................................................................................................... 79 5.1 Signal Definitions .............................................................................................. 79 6 Thermal Specifications ................................................................................................ 87 6.1 Package Thermal Specifications ........................................................................... 87 6.1.1 Thermal Specifications ............................................................................ 87 6.2 ...................................................................................................................... 95 6.2.1 Thermal Metrology ................................................................................. 97 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 3 6.3 6.4 Processor Thermal Features ................................................................................ 98 6.3.1 Thermal Monitor Features........................................................................ 98 6.3.2 Thermal Monitor (TM1) ........................................................................... 98 6.3.3 Thermal Monitor 2 .................................................................................. 99 6.3.4 On-Demand Mode ................................................................................ 100 6.3.5 PROCHOT# Signal ................................................................................ 101 6.3.6 FORCEPR# Signal................................................................................. 101 6.3.7 THERMTRIP# Signal ............................................................................. 102 Platform Environment Control Interface (PECI) .................................................... 102 6.4.1 Introduction ........................................................................................ 102 6.4.2 PECI Specifications ............................................................................... 103 7 Features.................................................................................................................. 105 7.1 Power-On Configuration Options........................................................................ 105 7.2 Clock Control and Low Power States .................................................................. 105 7.2.1 Normal State ....................................................................................... 106 7.2.2 HALT or Extended HALT State ................................................................ 106 7.2.3 Stop-Grant State.................................................................................. 108 7.2.4 Extended HALT Snoop or HALT Snoop State, Stop Grant Snoop State ........................................................................................ 109 7.3 Enhanced Intel SpeedStep® Technology ............................................................ 109 8 Boxed Processor Specifications ................................................................................... 111 8.1 Introduction ................................................................................................... 111 8.2 Mechanical Specifications ................................................................................. 113 8.2.1 Boxed Processor Heat Sink Dimensions (CEK) .......................................... 113 8.2.2 Boxed Processor Heat Sink Weight.......................................................... 121 8.2.3 Boxed Processor Retention Mechanism and Heat Sink Support (CEK) ..................................................................................... 121 8.3 Electrical Requirements .................................................................................... 121 8.3.1 Fan Power Supply (Active CEK) .............................................................. 121 8.3.2 Boxed Processor Cooling Requirements ................................................... 122 8.4 Boxed Processor Contents ................................................................................ 123 9 Debug Tools Specifications......................................................................................... 125 9.1 Debug Port System Requirements ..................................................................... 125 9.2 Target System Implementation ......................................................................... 125 9.2.1 System Implementation ........................................................................ 125 9.3 Logic Analyzer Interface (LAI) ........................................................................... 125 9.3.1 Mechanical Considerations ..................................................................... 126 9.3.2 Electrical Considerations........................................................................ 126 Figures 2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8 2-9 4 Input Device Hysteresis ..................................................................................... 27 Quad-Core Intel® Xeon® Processor E5300 Series Load Current versus Time............. 32 Quad-Core Intel® Xeon® Processor X5300 Series and Load Current versus Time................................................................................... 32 Quad-Core Intel® Xeon® Processor X5365 Series Load Current versus Time ............ 33 Quad-Core Intel® Xeon® Processor L5300 Series Load Current versus Time ............. 33 Quad-Core Intel® Xeon® Processor L5318 Load Current versus Time ...................... 34 Quad-Core Intel® Xeon® Processor E5300 Series VCC Static and Transient Tolerance Load Lines........................................................................... 35 Quad-Core Intel® Xeon® Processor X5300 Series VCC Static and Transient Tolerance Load Lines ........................................................................... 36 Quad-Core Intel® Xeon® Processor L5300 Series VCC Static and Transient Tolerance Load Lines........................................................................... 37 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 2-10 Quad-Core Intel® Xeon® Processor X5365 Series VCC Static and Transient Tolerance Load Lines ........................................................................... 39 2-11 Quad-Core Intel® Xeon® Processor L5318 VCC Static and Transient Tolerance Load Lines ........................................................................... 41 2-12 VCC Overshoot Example Waveform...................................................................... 43 2-13 Electrical Test Circuit ......................................................................................... 45 2-14 TCK Clock Waveform ......................................................................................... 45 2-15 Differential Clock Waveform................................................................................ 46 2-16 Differential Clock Crosspoint Specification............................................................. 46 3-1 Processor Package Assembly Sketch .................................................................... 47 3-2 Processor Package Drawing (Sheet 1 of 3) ............................................................ 48 3-3 Processor Package Drawing (Sheet 2 of 3) ............................................................ 49 3-4 Processor Package Drawing (Sheet 3 of 3) ............................................................ 50 3-5 Processor Top-side Markings (Example)................................................................ 53 3-6 Processor Land Coordinates, Top View.................................................................. 54 3-7 Processor Land Coordinates, Bottom View............................................................. 55 6-1 Quad-Core Intel® Xeon® Processor E5300 Series Thermal Profile ........................... 90 6-2 Quad-Core Intel® Xeon® Processor X5300 Series Thermal Profiles .......................... 91 6-3 Quad-Core Intel® Xeon® Processor X5365 Series Thermal Profile ........................... 93 6-4 Quad-Core Intel® Xeon® Processor L5300 Series Thermal Profile............................ 95 6-5 Quad-Core Intel® Xeon® Processor L5318 Thermal Profile ..................................... 96 6-6 Case Temperature (TCASE) Measurement Location ................................................ 98 6-7 Thermal Monitor 2 Frequency and Voltage Ordering ............................................. 100 6-8 PECI Topology ................................................................................................ 102 6-9 Conceptual Fan Control Diagram For A PECI-Based Platform.................................. 103 7-1 Stop Clock State Machine ................................................................................. 108 8-1 Boxed Quad-Core Intel® Xeon® Processor 5300 Series 1U Passive/3U+ Active Combination Heat Sink (With Removable Fan) ........................................... 111 8-2 Boxed Quad-Core Intel® Xeon® Processor 5300 Series 2U Passive Heat Sink ....................................................................................... 112 8-3 2U Passive Quad-Core Intel® Xeon® Processor 5300 Series Processor Thermal Solution (Exploded View) ..................................................................... 112 8-4 Top Side Board Keepout Zones (Part 1) .............................................................. 114 8-5 Top Side Board Keepout Zones (Part 2) .............................................................. 115 8-6 Bottom Side Board Keepout Zones..................................................................... 116 8-7 Board Mounting-Hole Keepout Zones ................................................................. 117 8-8 Volumetric Height Keep-Ins .............................................................................. 118 8-9 4-Pin Fan Cable Connector (For Active CEK Heat Sink) ......................................... 119 8-10 4-Pin Base Board Fan Header (For Active CEK Heat Sink)...................................... 120 8-11 Fan Cable Connector Pin Out for 4-Pin Active CEK Thermal Solution ....................... 122 Tables 1-1 2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8 Quad-Core Intel® Xeon® Processor 5300 Series Features ...................................... 12 Core Frequency to FSB Multiplier Configuration ..................................................... 20 BSEL[2:0] Frequency Table ................................................................................ 20 Voltage Identification Definition........................................................................... 22 Loadline Selection Truth Table for LL_ID[1:0] ....................................................... 23 Market Segment Selection Truth Table for MS_ID[1:0] ........................................... 23 FSB Signal Groups............................................................................................. 24 AGTL+ Signal Description Table........................................................................... 25 Non AGTL+ Signal Description Table .................................................................... 25 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 5 2-9 2-10 2-11 2-12 2-13 2-14 2-15 2-16 2-17 2-18 2-19 2-20 2-21 3-1 3-2 3-3 4-1 4-2 5-1 6-1 6-2 6-3 6-4 6-5 6-6 6-7 6-8 6-9 6-10 6-11 6-12 6-13 7-1 7-2 8-1 8-2 8-3 6 Signal Reference Voltages .................................................................................. 25 PECI DC Electrical Limits .................................................................................... 26 Processor Absolute Maximum Ratings................................................................... 28 Voltage and Current Specifications....................................................................... 29 VCC Static and Transient Tolerance for Quad-Core Intel® Xeon® Processor E5300 Series, Quad-Core Intel® Xeon® Processor X5300 Series, Quad-Core Intel® Xeon® Processor L5300 Series ................................................. 34 VCC Static and Transient Tolerance for Quad-Core Intel® Xeon® Processor X5365 Series...................................................................................... 37 VCC Static and Transient Tolerance for Quad-Core Intel® Xeon® Processor L5318 Series ..................................................................................... 40 AGTL+ Signal Group Specifications ...................................................................... 41 CMOS Signal Input/Output Group and TAP Signal Group DC Specifications ................ 42 Open Drain Output Signal Group DC Specifications ................................................ 42 VCC Overshoot Specifications.............................................................................. 42 AGTL+ Bus Voltage Definitions ............................................................................ 44 FSB Differential BCLK Specifications..................................................................... 44 Package Loading Specifications ........................................................................... 51 Package Handling Guidelines............................................................................... 52 Processor Materials............................................................................................ 52 Land Listing by Land Name ................................................................................. 57 Land Listing by Land Number .............................................................................. 69 Signal Definitions .............................................................................................. 79 Quad-Core Intel® Xeon® Processor E5300 Series Thermal Specifications ................. 89 Quad-Core Intel® Xeon® Processor E5300 Series Thermal Profile Table ................... 90 Quad-Core Intel® Xeon® Processor X5300 Series Thermal Specifications ................. 91 Quad-Core Intel® Xeon® Processor X5300 Series Thermal Profile A Table ................ 92 Quad-Core Intel® Xeon® Processor X5300 Series Thermal Profile B Table ................ 92 Quad-Core Intel® Xeon® Processor X5365 Series Thermal Specifications ................. 93 Quad-Core Intel® Xeon® Processor X5365 Series Thermal Profile (Sheet 1 of 2) ............................................................................ 94 Quad-Core Intel® Xeon® Processor L5300 Series Thermal Specifications ................. 94 Quad-Core Intel® Xeon® Processor L5300 Series Thermal Profile............................ 95 Quad-Core Intel® Xeon® Processor L5318 Thermal Specifications ........................... 95 Quad-Core Intel® Xeon® Processor L5318 Nominal Thermal Profile ......................... 97 Quad-Core Intel® Xeon® Processor L5318 Short Term Thermal Profile .................... 97 GetTemp0() and GetTemp1() Error Codes .......................................................... 104 Power-On Configuration Option Lands ................................................................ 105 Extended HALT Maximum Power........................................................................ 107 PWM Fan Frequency Specifications for 4-Pin Active CEK Thermal Solution ............... 122 Fan Specifications for 4-Pin Active CEK Thermal Solution ...................................... 122 Fan Cable Connector Pin Out for 4-Pin Active CEK Thermal Solution ....................... 122 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Revision History Revision 001 Description Date Initial Release November 2006 002 Added Quad-Core Intel® Xeon® Processor L5300 Series 003 Included the G-step information. Added the Quad-Core Intel® Xeon® Processor L5318. March 2007 September 2007 § Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 7 8 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Introduction 1 Introduction The Quad-Core Intel® Xeon® Processor 5300 Series are 64-bit server/workstation processors utilizing four Intel Core™ microarchitecture cores. These processors are based on Intel’s 65 nanometer process technology combining high performance with the power efficiencies of low-power Intel Core™ microarchitecture cores. The QuadCore Intel® Xeon® Processor 5300 Series consists of two die, each containing two processor cores. All processors maintain the tradition of compatibility with IA-32 software. Some key features include on-die, 32 KB Level 1 instruction data caches per core and 4 MB shared Level 2 cache per die (8 MB Total Cache per processor) with Advanced Transfer Cache Architecture. The processor’s Data Prefetch Logic speculatively fetches data to the L2 cache before an L1 cache requests occurs, resulting in reduced bus cycle penalties and improved performance. The 1333 MHz Front Side Bus (FSB) is a quad-pumped bus running off a 333 MHz system clock, which results in 10.6 GBytes per second data transfer. The 1066 MHz Front Side Bus is based on a 266 MHz system clock for an 8.5 GBytes per second data transfer rate. The Quad-Core Intel® Xeon® Processor X5300 Series offers higher clock frequencies than the Quad-Core Intel® Xeon® Processor E5300 Series for platforms that are targeted for the performance optimized segment. The Quad-Core Intel® Xeon® Processor L5300 Series is a lower voltage, lower power processor intended for ultra dense platforms. Enhanced thermal and power management capabilities are implemented including Thermal Monitor 1 (TM1), Thermal Monitor 2 (TM2) and Enhanced Intel SpeedStep® Technology. TM1 and TM2 provide efficient and effective cooling in high temperature situations. Enhanced Intel SpeedStep® Technology provides power management capabilities to servers and workstations. The Quad-Core Intel® Xeon® Processor 5300 Series features include Advanced Dynamic Execution, enhanced floating point and multi-media units, Streaming SIMD Extensions 2 (SSE2) and Streaming SIMD Extensions 3 (SSE3). Advanced Dynamic Execution improves speculative execution and branch prediction internal to the processor. The floating point and multi-media units include 128-bit wide registers and a separate register for data movement. SSE3 instructions provide highly efficient doubleprecision floating point, SIMD integer, and memory management operations. The Quad-Core Intel® Xeon® Processor 5300 Series supports Intel® 64 architecture as an enhancement to Intel's IA-32 architecture. This enhancement allows the processor to execute operating systems and applications written to take advantage of the 64-bit extension technology. Further details on Intel 64 architecture and its programming model can be found in the Intel® 64 and IA-32 Architecture Software Developer's Manual. In addition, the Quad-Core Intel® Xeon® Processor 5300 Series supports the Execute Disable Bit functionality. When used in conjunction with a supporting operating system, Execute Disable allows memory to be marked as executable or non executable. This feature can prevent some classes of viruses that exploit buffer overrun vulnerabilities and can thus help improve the overall security of the system. Further details on Execute Disable can be found at http://www.intel.com/cd/ids/developer/ asmo-na/eng/149308.htm. The Quad-Core Intel® Xeon® Processor 5300 Series supports Intel® Virtualization Technology for hardware-assisted virtualization within the processor. Intel Virtualization Technology is a set of hardware enhancements that can improve virtualization solutions. Intel Virtualization Technology is used in conjunction with Virtual Machine Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 11 Introduction Monitor software enabling multiple, independent software environments inside a single platform. Further details on Intel Virtualization Technology can be found at http://developer.intel.com/technology/vt. The Quad-Core Intel® Xeon® Processor 5300 Series are intended for high performance server and workstation systems. The processors support a Dual Independent Bus (DIB) architecture with one processor on each bus, up to two processor sockets in a system. The DIB architecture provides improved performance by allowing increased FSB speeds and bandwidth. The processors will be packaged in an FC-LGA6 Land Grid Array package with 771 lands for improved power delivery. It utilizes a surface mount LGA771 socket that supports Direct Socket Loading (DSL). Table 1-1. Quad-Core Intel® Xeon® Processor 5300 Series Features # of Processor Cores L1 Cache (per core) L2 Advanced Transfer Cache Front Side Bus Frequency Package 4 32 KB instruction 32 KB data 4MB Shared L2 Cache per die 8MB Total Cache 1333 MHz 1066 MHz FC-LGA6 771 Lands Quad-Core Intel® Xeon® Processor 5300 Series based platforms implement independent core voltage (VCC) power planes for each processor. FSB termination voltage (VTT) is shared and must connect to all FSB agents. The processor core voltage utilizes power delivery guidelines specified by VRM/EVRD 11.0 and its associated load line (see Voltage Regulator Module (VRM) and Enterprise Voltage Regulator-Down (EVRD) 11.0 Design Guidelines for further details). VRM/EVRD 11.0 will support the power requirements of all frequencies of the processors including Flexible Motherboard Guidelines (FMB) (see Section 2.13.1). Refer to the appropriate platform design guidelines for implementation details. The Quad-Core Intel® Xeon® Processor 5300 Series support 1333, or 1066 MHz Front Side Bus operation. The FSB utilizes a split-transaction, deferred reply protocol and Source-Synchronous Transfer (SST) of address and data to improve performance. The processor transfers data four times per bus clock (4X data transfer rate, as in AGP 4X). Along with the 4X data bus, the address bus can deliver addresses two times per bus clock and is referred to as a ‘double-clocked’ or a 2X address bus. In addition, the Request Phase completes in one clock cycle. Working together, the 4X data bus and 2X address bus provide a data bus bandwidth of up to 10.66 GBytes (1333 MHz), or 8.5 GBytes (1066 MHz) per second. The FSB is also used to deliver interrupts. Signals on the FSB use Assisted Gunning Transceiver Logic (AGTL+) level voltages. Section 2.1 contains the electrical specifications of the FSB while implementation details are fully described in the appropriate platform design guidelines (refer to Section 1.3). 12 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Introduction 1.1 Terminology A ‘#’ symbol after a signal name refers to an active low signal, indicating a signal is in the asserted state when driven to a low level. For example, when RESET# is low, a reset has been requested. Conversely, when NMI is high, a nonmaskable interrupt has occurred. In the case of signals where the name does not imply an active state but describes part of a binary sequence (such as address or data), the ‘#’ symbol implies that the signal is inverted. For example, D[3:0] = ‘HLHL’ refers to a hex ‘A’, and D[3:0]# = ‘LHLH’ also refers to a hex ‘A’ (H= High logic level, L= Low logic level). Commonly used terms are explained here for clarification: • Quad-Core Intel® Xeon® Processor 5300 Series – Intel 64-bit microprocessor intended for dual processor servers and workstations. The Quad-Core Intel® Xeon® Processor 5300 Series is based on Intel’s 65 nanometer process, in the FC-LGA6 package with four processor cores. For this document, “processor” is used as the generic term for the “Quad-Core Intel® Xeon® Processor 5300 Series”. The term ‘processors’ and “Quad-Core Intel® Xeon® Processor 5300 Series” are inclusive of Quad-Core Intel® Xeon® Processor E5300 Series, Quad-Core Intel® Xeon® Processor X5300 Series and Quad-Core Intel® Xeon® Processor L5300 Series. • Quad-Core Intel® Xeon® Processor E5300 Series – A mainstream performance version of the Quad-Core Intel® Xeon® Processor 5300 Series. For this document “Quad-Core Intel® Xeon® Processor E5300 Series” is used to call out specifications that are unique to the Quad-Core Intel® Xeon® Processor E5300 Series SKU. • Quad-Core Intel® Xeon® Processor X5300 Series – An accelerated performance version of the Quad-Core Intel® Xeon® Processor 5300 Series. For this document “Quad-Core Intel® Xeon® Processor X5300 Series” is used to call out specifications that are unique to the Quad-Core Intel® Xeon® Processor X5300 Series SKU. • Quad-Core Intel® Xeon® Processor X5365 Series– An ultra performance version of the Quad-Core Intel® Xeon® Processor 5300 Series. For this document “Quad-Core Intel® Xeon® Processor X5365 Series” is used to call out specifications that are unique to the Quad-Core Intel® Xeon® Processor X5365 Series SKU. • Quad-Core Intel® Xeon® Processor L5300 Series - Intel 64-bit microprocessor intended for dual processor server blades and embedded servers. The Quad-Core Intel® Xeon® Processor L5300 Series is a lower voltage, lower power version of the Quad-Core Intel® Xeon® Processor 5300 Series. For this document “Quad-Core Intel® Xeon® Processor L5300 Series” is used to call out specifications that are unique to the Quad-Core Intel® Xeon® Processor L5300 Series. • Quad-Core Intel® Xeon® Processor L5318 - Intel 64-bit microprocessor intended for dual processor server blades and embedded servers requiring higher case temperatures. The Quad-Core Intel® Xeon® Processor L5318 is a lower voltage, lower power version of the Quad-Core Intel® Xeon® Processor 5300 Series. For this document “Quad-Core Intel® Xeon® Processor L5318” is used to call out specifications that are unique to the Quad-Core Intel® Xeon® Processor L5318 SKU. • FC-LGA6 (Flip Chip Land Grid Array) Package – The Quad-Core Intel® Xeon® Processor 5300 Series package is a Land Grid Array, consisting of a processor core mounted on a pinless substrate with 771 lands, and includes an integrated heat spreader (IHS). Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 13 Introduction • LGA771 socket – The Quad-Core Intel® Xeon® Processor 5300 Series interfaces to the baseboard through this surface mount, 771 Land socket. See the LGA771 Socket Design Guidelines for details regarding this socket. • Processor core – Processor core with integrated L1 cache. L2 cache and system bus interface are shared between the two cores on the die. All AC timing and signal integrity specifications are at the pads of the processor die. • FSB (Front Side Bus) – The electrical interface that connects the processor to the chipset. Also referred to as the processor system bus or the system bus. All memory and I/O transactions as well as interrupt messages pass between the processor and chipset over the FSB. • Dual Independent Bus (DIB) – A front side bus architecture with one processor on each bus, rather than a FSB shared between two processor agents. The DIB architecture provides improved performance by allowing increased FSB speeds and bandwidth. • Flexible Motherboard Guidelines (FMB) – Are estimates of the maximum values the Quad-Core Intel® Xeon® Processor 5300 Series will have over certain time periods. The values are only estimates and actual specifications for future processors may differ. • Functional Operation – Refers to the normal operating conditions in which all processor specifications, including DC, AC, FSB, signal quality, mechanical and thermal are satisfied. • Storage Conditions – Refers to a non-operational state. The processor may be installed in a platform, in a tray, or loose. Processors may be sealed in packaging or exposed to free air. Under these conditions, processor lands should not be connected to any supply voltages, have any I/Os biased or receive any clocks. Upon exposure to “free air” (that is, unsealed packaging or a device removed from packaging material) the processor must be handled in accordance with moisture sensitivity labeling (MSL) as indicated on the packaging material. • Priority Agent – The priority agent is the host bridge to the processor and is typically known as the chipset. • Symmetric Agent – A symmetric agent is a processor which shares the same I/O subsystem and memory array, and runs the same operating system as another processor in a system. Systems using symmetric agents are known as Symmetric Multiprocessing (SMP) systems. • Integrated Heat Spreader (IHS) – A component of the processor package used to enhance the thermal performance of the package. Component thermal solutions interface with the processor at the IHS surface. • Thermal Design Power – Processor thermal solutions should be designed to meet this target. It is the highest expected sustainable power while running known power intensive real applications. TDP is not the maximum power that the processor can dissipate. • Intel® 64 Architecture – Instruction set architecture and programming environment of Intel’s 64-bit processors, which are a superset of and compatible with IA-32. This 64-bit instruction set architecture was formerly known as IA-32 with EM64T or Intel® EM64T. • Enhanced Intel SpeedStep® Technology – Technology that provides power management capabilities to servers and workstations. • Platform Environment Control Interface (PECI) – A proprietary one-wire bus interface that provides a communication channel between Intel processor and chipset components to external thermal monitoring devices, for use in fan speed control. PECI communicates readings from the processor’s Digital Thermal Sensor (DTS). The replaces the thermal diode available in previous processors. 14 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Introduction • Intel® Virtualization Technology (Intel® VT) – Processor virtualization which when used in conjunction with Virtual Machine Monitor software enables multiple, robust independent software environments inside a single platform. • VRM (Voltage Regulator Module) – DC-DC converter built onto a module that interfaces with a card edge socket and supplies the correct voltage and current to the processor based on the logic state of the processor VID bits. • EVRD (Enterprise Voltage Regulator Down) – DC-DC converter integrated onto the system board that provides the correct voltage and current to the processor based on the logic state of the processor VID bits. • VCC – The processor core power supply. • VSS – The processor ground. • VTT – FSB termination voltage. (Note: In some Intel processor EMTS documents, VTT is instead called VCCP.) 1.2 State of Data The data contained within this document is the most accurate information available by the publication date of this document. 1.3 References Material and concepts available in the following documents may be beneficial when reading this document: Document AP-485, Intel® Processor Identification and the CPUID Instruction Intel® Intel® Intel® Intel® Intel® 64 64 64 64 64 and and and and and IA-32 IA-32 IA-32 IA-32 IA-32 Architectures Architectures Architectures Architectures Architectures Software Software Software Software Software Developer’s Developer’s Developer’s Developer’s Developer’s Manual, Manual, Manual, Manual, Manual, Volume Volume Volume Volume Volume IA-32 Intel® Architecture Optimization Reference Manual Quad-Core Intel® Xeon® Processor 5300 Series Specification Update Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 1 2A 2B 3A 3B Document Number1 Notes 241618 2 253665 253666 253667 253668 253669 2 248966 2 3 15 Introduction Document Number1 Document Notes Quad-Core Intel® Xeon® Processor 5300 Series Thermal/Mechanical Design Guidelines Clovertown Processor Boundary Scan Descriptive Language (BSDL) Model Debug Port Design Guide for UP/DP Systems 10 1 Notes: Contact your Intel representative for the latest revision of these documents. § 16 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Electrical Specifications 2 Electrical Specifications 2.1 Front Side Bus and GTLREF Most Quad-Core Intel® Xeon® Processor 5300 Series FSB signals use Assisted Gunning Transceiver Logic (AGTL+) signaling technology. This technology provides improved noise margins and reduced ringing through low voltage swings and controlled edge rates. AGTL+ buffers are open-drain and require pull-up resistors to provide the high logic level and termination. AGTL+ output buffers differ from GTL+ buffers with the addition of an active PMOS pull-up transistor to “assist” the pull-up resistors during the first clock of a low-to-high voltage transition. Platforms implement a termination voltage level for AGTL+ signals defined as VTT. Because platforms implement separate power planes for each processor (and chipset), separate VCC and VTT supplies are necessary. This configuration allows for improved noise tolerance as processor frequency increases. Speed enhancements to data and address buses have made signal integrity considerations and platform design methods even more critical than with previous processor families. Design guidelines for the processor FSB are detailed in the appropriate platform design guidelines (refer to Section 1.3). The AGTL+ inputs require reference voltages (GTLREF_DATA_MID, GTLREF_DATA_END, GTLREF_ADD_MID and GTLREF_ADD_END) which are used by the receivers to determine if a signal is a logical 0 or a logical 1. GTLREF_DATA_MID and GTLREF_DATA_END are used for the 4X front side bus signaling group and GTLREF_ADD_MID and GTLREF_ADD_END are used for the 2X and common clock front side bus signaling groups. GTLREF_DATA_MID, GTLREF_DATA_END, GTLREF_ADD_MID, and GTLREF_ADD_END must be generated on the baseboard (See Table 2-20 for GTLREF_DATA_MID, GTLREF_DATA_END, GTLREF_ADD_MID and GTLREF_ADD_END specifications). Refer to the applicable platform design guidelines for details. Termination resistors (RTT) for AGTL+ signals are provided on the processor silicon and are terminated to VTT. The on-die termination resistors are always enabled on the processor to control reflections on the transmission line. Intel chipsets also provide on-die termination, thus eliminating the need to terminate the bus on the baseboard for most AGTL+ signals. Some FSB signals do not include on-die termination (RTT) and must be terminated on the baseboard. See Table 2-7 and Table 2-8 for details regarding these signals. The AGTL+ bus depends on incident wave switching. Therefore, timing calculations for AGTL+ signals are based on flight time as opposed to capacitive deratings. Analog signal simulation of the FSB, including trace lengths, is highly recommended when designing a system. Contact your Intel Field Representative to obtain the applicable signal integrity models, which includes buffer and package models. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 17 Electrical Specifications 2.2 Power and Ground Lands For clean on-chip processor core power distribution, the processor has 223 VCC (power) and 267 VSS (ground) inputs. All VCC lands must be connected to the processor power plane, while all VSS lands must be connected to the system ground plane. The processor VCC lands must be supplied with the voltage determined by the processor Voltage IDentification (VID) signals. See Table 2-3 for VID definitions. Twenty two lands are specified as VTT, which provide termination for the FSB and provides power to the I/O buffers. The platform must implement a separate supply for these lands which meets the VTT specifications outlined in Table 2-12. 2.3 Decoupling Guidelines Due to its large number of transistors and high internal clock speeds, the processor is capable of generating large average current swings between low and full power states. This may cause voltages on power planes to sag below their minimum values if bulk decoupling is not adequate. Larger bulk storage (CBULK), such as electrolytic capacitors, supply current during longer lasting changes in current demand by the component, such as coming out of an idle condition. Similarly, they act as a storage well for current when entering an idle condition from a running condition. Care must be taken in the baseboard design to ensure that the voltage provided to the processor remains within the specifications listed in Table 2-12. Failure to do so can result in timing violations or reduced lifetime of the component. For further information and guidelines, refer to the appropriate platform design guidelines. 2.3.1 VCC Decoupling Vcc regulator solutions need to provide bulk capacitance with a low Effective Series Resistance (ESR), and the baseboard designer must assure a low interconnect resistance from the regulator (EVRD or VRM pins) to the LGA771 socket. Bulk decoupling must be provided on the baseboard to handle large current swings. The power delivery solution must insure the voltage and current specifications are met (as defined in Table 2-12). For further information regarding power delivery, decoupling and layout guidelines, refer to the appropriate platform design guidelines. 2.3.2 VTT Decoupling Bulk decoupling must be provided on the baseboard. Decoupling solutions must be sized to meet the expected load. To insure optimal performance, various factors associated with the power delivery solution must be considered including regulator type, power plane and trace sizing, and component placement. A conservative decoupling solution consists of a combination of low ESR bulk capacitors and high frequency ceramic capacitors. For further information regarding power delivery, decoupling and layout guidelines, refer to the appropriate platform design guidelines. 18 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Electrical Specifications 2.3.3 Front Side Bus AGTL+ Decoupling The processor integrates signal termination on the die, as well as a portion of the required high frequency decoupling capacitance on the processor package. However, additional high frequency capacitance must be added to the baseboard to properly decouple the return currents from the FSB. Bulk decoupling must also be provided by the baseboard for proper AGTL+ bus operation. Decoupling guidelines are described in the appropriate platform design guidelines. 2.4 Front Side Bus Clock (BCLK[1:0]) and Processor Clocking BCLK[1:0] directly controls the FSB interface speed as well as the core frequency of the processor. As in previous processor generations, the processor core frequency is a multiple of the BCLK[1:0] frequency. The processor bus ratio multiplier is set during manufacturing. The default setting is for the maximum speed of the processor. It is possible to override this setting using software (see the Conroe and Woodcrest Processor Family BIOS Writer’s Guide). This permits operation at lower frequencies than the processor’s tested frequency. The processor core frequency is configured during reset by using values stored internally during manufacturing. The stored value sets the highest bus fraction at which the particular processor can operate. If lower speeds are desired, the appropriate ratio can be configured via the CLOCK_FLEX_MAX Model Specific Register (MSR). For details of operation at core frequencies lower than the maximum rated processor speed, refer to the Intel® 64 and IA-32 Architectures Software Developer’s Manual. Clock multiplying within the processor is provided by the internal phase locked loop (PLL), which requires a constant frequency BCLK[1:0] input, with exceptions for spread spectrum clocking. Processor DC specifications for the BCLK[1:0] inputs are provided in Table 2-21. These specifications must be met while also meeting signal integrity requirements as outlined in Table 2-21. The processor utilizes differential clocks. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 19 Electrical Specifications Table 2-1. Core Frequency to FSB Multiplier Configuration Core Frequency to FSB Multiplier Core Frequency with 333.333 MHz Bus Clock Core Frequency with 266.666 MHz Bus Clock Notes 1/6 2 GHz 1.60 GHz 1, 2, 3, 4 1/7 2.33 GHz 1.86 GHz 1, 2, 3 1/8 2.66 GHz 2.13 GHz 1, 2, 3 1/9 3 GHz 2.40 GHz 1, 2, 3 1/10 3.33 GHz 2.66 GHz 1, 2, 3 1/11 3.66 GHz 2.93 GHz 1, 2, 3 1/12 4 GHz 3.20 GHz 1, 2, 3 Notes: 1. Individual processors operate only at or below the frequency marked on the package. 2. Listed frequencies are not necessarily committed production frequencies. 3. For valid processor core frequencies, refer to the Quad-Core Intel® Xeon® Processor 5300 Series Specification Update. 4. The lowest bus ratio supported is 1/6. 2.4.1 Front Side Bus Frequency Select Signals (BSEL[2:0]) Upon power up, the FSB frequency is set to the maximum supported by the individual processor. BSEL[2:0] are CMOS outputs which must be pulled up to VTT, and are used to select the FSB frequency. Please refer to Table 2-17 for DC specifications. Table 2-2 defines the possible combinations of the signals and the frequency associated with each combination. The frequency is determined by the processor(s), chipset, and clock synthesizer. All FSB agents must operate at the same core and FSB frequency. See the appropriate platform design guidelines for further details. Table 2-2. 20 BSEL[2:0] Frequency Table BSEL2 BSEL1 BSEL0 Bus Clock Frequency 0 0 0 266.666 MHz 0 0 1 Reserved 0 1 0 Reserved 0 1 1 Reserved 1 0 0 333.333 MHz 1 0 1 Reserved 1 1 0 Reserved 1 1 1 Reserved Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Electrical Specifications 2.4.2 PLL Power Supply An on-die PLL filter solution is implemented on the processor. The VCCPLL input is used to provide power to the on chip PLL of the processor. Please refer to Table 2-12 for DC specifications. Refer to the appropriate platform design guidelines for decoupling and routing guidelines. 2.5 Voltage Identification (VID) The Voltage Identification (VID) specification for the processor is defined by the Voltage Regulator Module (VRM) and Enterprise Voltage Regulator-Down (EVRD) 11.0 Design Guidelines. The voltage set by the VID signals is the reference VR output voltage to be delivered to the processor Vcc pins. Please refer to Table 2-18 for the DC specifications for these signals. A voltage range is provided in Table 2-12 and changes with frequency. The specifications have been set such that one voltage regulator can operate with all supported frequencies. Individual processor VID values may be calibrated during manufacturing such that two devices at the same core frequency may have different default VID settings. This is reflected by the VID range values provided in Table 2-3. The Quad-Core Intel® Xeon® Processor 5300 Series uses six voltage identification signals, VID[6:1], to support automatic selection of power supply voltages. Table 2-3 specifies the voltage level corresponding to the state of VID[6:1]. A ‘1’ in this table refers to a high voltage level and a ‘0’ refers to a low voltage level. The definition provided in Table 2-3 is not related in any way to previous Intel® Xeon® processors or voltage regulator designs. If the processor socket is empty (VID[6:1] = 111111), or the voltage regulation circuit cannot supply the voltage that is requested, the voltage regulator must disable itself. See the Voltage Regulator Module (VRM) and Enterprise Voltage Regulator-Down (EVRD) 11.0 Design Guidelines for further details. Although the Voltage Regulator Module (VRM) and Enterprise Voltage Regulator-Down (EVRD) 11.0 Design Guidelines defines VID[7:0], VID[7] and VID[0] are not used on the Quad-Core Intel® Xeon® Processor 5300 Series. Please refer to the Quad-Core Intel® Xeon® Processor E5300 Series, Harpertown and Wolfdale-DP Processors Compatibility Design Guide for details. The Quad-Core Intel® Xeon® Processor 5300 Series provide the ability to operate while transitioning to an adjacent VID and its associated processor core voltage (VCC). This will represent a DC shift in the load line. It should be noted that a low-to-high or high-to-low voltage state change may result in as many VID transitions as necessary to reach the target core voltage. Transitions above the specified VID are not permitted. Table 2-12 includes VID step sizes and DC shift ranges. Minimum and maximum voltages must be maintained as shown in Table 2-13. The VRM or EVRD utilized must be capable of regulating its output to the value defined by the new VID. DC specifications for dynamic VID transitions are included in Table 2-12. Refer to the Voltage Regulator Module (VRM) and Enterprise Voltage Regulator-Down (EVRD) 11.0 Design Guidelines for further details. Power source characteristics must be guaranteed to be stable whenever the supply to the voltage regulator is stable. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 21 Electrical Specifications Table 2-3. HEX VID6 400 mV Voltage Identification Definition VID5 200 mV VID4 100 mV VID3 50 mV VID2 25 mV VID1 12.5 mV VCC_MAX HEX VID6 400 mV VID5 200 mV VID4 100 mV VID3 50 mV VID2 25 mV VID1 12.5 mV VCC_MAX 7A 1 1 1 1 0 1 0.8500 3C 0 1 1 1 1 0 1.2375 78 1 1 1 1 0 0 0.8625 3A 0 1 1 1 0 1 1.2500 76 1 1 1 0 1 1 0.8750 38 0 1 1 1 0 0 1.2625 74 1 1 1 0 1 0 0.8875 36 0 1 1 0 1 1 1.2750 72 1 1 1 0 0 1 0.9000 34 0 1 1 0 1 0 1.2875 70 1 1 1 0 0 0 0.9125 32 0 1 1 0 0 1 1.3000 6E 1 1 0 1 1 1 0.9250 30 0 1 1 0 0 0 1.3125 6C 1 1 0 1 1 0 0.9375 2E 0 1 0 1 1 1 1.3250 6A 1 1 0 1 0 1 0.9500 2C 0 1 0 1 1 0 1.3375 68 1 1 0 1 0 0 0.9625 2A 0 1 0 1 0 1 1.3500 66 1 1 0 0 1 1 0.9750 28 0 1 0 1 0 0 1.3625 64 1 1 0 0 1 0 0.9875 26 0 1 0 0 1 1 1.3750 62 1 1 0 0 0 1 1.0000 24 0 1 0 0 1 0 1.3875 60 1 1 0 0 0 0 1.0125 22 0 1 0 0 0 1 1.4000 5E 1 0 1 1 1 1 1.0250 20 0 1 0 0 0 0 1.4125 5C 1 0 1 1 1 0 1.0375 1E 0 0 1 1 1 1 1.4250 5A 1 0 1 1 0 1 1.0500 1C 0 0 1 1 1 0 1.4375 58 1 0 1 1 0 0 1.0625 1A 0 0 1 1 0 1 1.4500 56 1 0 1 0 1 1 1.0750 18 0 0 1 1 0 0 1.4625 54 1 0 1 0 1 0 1.0875 16 0 0 1 0 1 1 1.4750 52 1 0 1 0 0 1 1.1000 14 0 0 1 0 1 0 1.4875 50 1 0 1 0 0 0 1.1125 12 0 0 1 0 0 1 1.5000 4E 1 0 0 1 1 1 1.1250 10 0 0 1 0 0 0 1.5125 4C 1 0 0 1 1 0 1.1375 0E 0 0 0 1 1 1 1.5250 4A 1 0 0 1 0 1 1.1500 0C 0 0 0 1 1 0 1.5375 48 1 0 0 1 0 0 1.1625 0A 0 0 0 1 0 1 1.5500 46 1 0 0 0 1 1 1.1750 08 0 0 0 1 0 0 1.5625 44 1 0 0 0 1 0 1.1875 06 0 0 0 0 1 1 1.5750 42 1 0 0 0 0 1 1.2000 04 0 0 0 0 1 0 1.5875 40 1 0 0 0 0 0 1.2125 02 0 0 0 0 0 1 1.6000 3E 0 1 1 1 1 1 1.2250 00 0 0 0 0 0 0 OFF1 Notes: 1. When the “111111” VID pattern is observed, the voltage regulator output should be disabled. 2. Shading denotes the expected VID range of the Quad-Core Intel® Xeon® Processor 5300 Series. 3. The VID range includes VID transitions that may be initiated by thermal events, assertion of the FORCEPR# signal (see Section 6.3.3), Extended HALT state transitions (see Section 7.2.2), or Enhanced Intel SpeedStep® Technology transitions (see Section 7.3). The Extended HALT state must be enabled for the processor to remain within its specifications. 4. Once the VRM/EVRD is operating after power-up, if either the Output Enable signal is de-asserted or a specific VID off code is received, the VRM/EVRD must turn off its output (the output should go to high impedance) within 500 ms and latch off until power is cycled. Refer to Voltage Regulator Module (VRM) and Enterprise Voltage Regulator-Down (EVRD) 11.0 Design Guidelines. 22 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Electrical Specifications Table 2-4. Loadline Selection Truth Table for LL_ID[1:0] LL_ID1 LL_ID0 0 0 Reserved 0 1 Dual-Core Intel® Xeon® Processor 5000 Series Dual-Core Intel® Xeon® Processor 5100 Series 1 0 Reserved 1 1 Quad-Core Intel® Xeon® Processor 5300 Series Note: Table 2-5. The LL_ID[1:0] signals are used by the platform to select the correct loadline slope for the processor. Market Segment Selection Truth Table for MS_ID[1:0] MS_ID1 MS_ID0 0 0 Dual-Core Intel® Xeon® Processor 5000 Series 0 1 Dual-Core Intel® Xeon® Processor 5100 Series 1 0 All Quad-Core Intel® Xeon® Processor 5300 Series 1 1 Reserved Note: 2.6 Description Description The MS_ID[1:0] signals are provided to indicate the Market Segment for the processor and may be used for future processor compatibility or for keying. Reserved, Unused, or Test Signals All Reserved signals must remain unconnected. Connection of these signals to VCC, VTT, VSS, or to any other signal (including each other) can result in component malfunction or incompatibility with future processors. See Section 4 for a land listing of the processor and the location of all Reserved signals. For reliable operation, always connect unused inputs or bidirectional signals to an appropriate signal level. Unused active high inputs, should be connected through a resistor to ground (VSS). Unused outputs can be left unconnected; however, this may interfere with some TAP functions, complicate debug probing, and prevent boundary scan testing. A resistor must be used when tying bidirectional signals to power or ground. When tying any signal to power or ground, a resistor will also allow for system testability. Resistor values should be within ± 20% of the impedance of the baseboard trace for FSB signals, unless otherwise noticed in the appropriate platform design guidelines. For unused AGTL+ input or I/O signals, use pull-up resistors of the same value as the on-die termination resistors (RTT). For details see Table 2-20. Some TAP, CMOS inputs and outputs do not include on-die termination. Inputs and utilized outputs must be terminated on the baseboard. Unused outputs may be terminated on the baseboard or left unconnected. Note that leaving unused outputs unterminated may interfere with some TAP functions, complicate debug probing, and prevent boundary scan testing. Signal termination for these signal types is discussed in the appropriate platform design guidelines. For each processor socket, connect the TESTIN1 and TESTIN2 signals together, then terminate the net with a 51 Ω resistor to VTT. Each of the TESTHI signals must be tied to the processor VTT individually using a matched resistor, where a matched resistor has a resistance value within ± 20% of the impedance of the board transmission line traces. For example, if the trace impedance is 50 Ω, then a value between 40 Ω and 60 Ω is required. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 23 Electrical Specifications 2.7 Front Side Bus Signal Groups The FSB signals have been combined into groups by buffer type. AGTL+ input signals have differential input buffers, which use GTLREF_DATA_MID, GTLREF_DATA_END, GTLREF_ADD_MID, and GTLREF_ADD_END as reference levels. In this document, the term “AGTL+ Input” refers to the AGTL+ input group as well as the AGTL+ I/O group when receiving. Similarly, “AGTL+ Output” refers to the AGTL+ output group as well as the AGTL+ I/O group when driving. AGTL+ outputs can become active anytime and include an active PMOS pull-up transistor to assist during the first clock of a low-to-high voltage transition. With the implementation of a source synchronous data bus comes the need to specify two sets of timing parameters. One set is for common clock signals whose timings are specified with respect to rising edge of BCLK0 (ADS#, HIT#, HITM#, etc.) and the second set is for the source synchronous signals which are relative to their respective strobe lines (data and address) as well as rising edge of BCLK0. Asynchronous signals are still present (A20M#, IGNNE#, etc.) and can become active at any time during the clock cycle. Table 2-6 identifies which signals are common clock, source synchronous and asynchronous. Table 2-6. FSB Signal Groups (Sheet 1 of 2) Signal Group 24 Signals1 Type AGTL+ Common Clock Input Synchronous to BCLK[1:0] BPRI#, DEFER#, RESET#, RS[2:0]#, RSP#, TRDY#; AGTL+ Common Clock Output Synchronous to BCLK[1:0] BPM4#, BPM[2:1]#, BPMb[2:1]# AGTL+ Common Clock I/O Synchronous to BCLK[1:0] ADS#, AP[1:0]#, BINIT#2, BNR#2, BPM5#, BPM3#, BPM0#, BPMb3#, BPMb0#, BR[1:0]#, DBSY#, DP[3:0]#, DRDY#, HIT#2, HITM#2, LOCK#, MCERR#2 AGTL+ Source Synchronous I/O Synchronous to assoc. strobe Signals Associated Strobe REQ[4:0]#,A[16:3]#, A[37:36]#3 ADSTB0# A[35:17]# ADSTB1# D[15:0]#, DBI0# DSTBP0#, DSTBN0# D[31:16]#, DBI1# DSTBP1#, DSTBN1# D[47:32]#, DBI2# DSTBP2#, DSTBN2# D[63:48]#, DBI3# DSTBP3#, DSTBN3# AGTL+ Strobes I/O Synchronous to BCLK[1:0] ADSTB[1:0]#, DSTBP[3:0]#, DSTBN[3:0]# Open Drain Output Asynchronous FERR#/PBE#, IERR#, PROCHOT#, THERMTRIP# CMOS Asynchronous Input Asynchronous A20M#, FORCEPR#, IGNNE#, INIT#, LINT0/ INTR, LINT1/NMI, PWRGOOD, SMI#, STPCLK#, CMOS Asynchronous Output Asynchronous BSEL[2:0], VID[6:1] FSB Clock Clock BCLK[1:0] Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Electrical Specifications Table 2-6. FSB Signal Groups (Sheet 2 of 2) Signal Group Signals1 Type TAP Input Synchronous to TCK TCK, TDI, TMS, TRST# TAP Output Synchronous to TCK TDO Power/Other Power/Other COMP[3:0], GTLREF_ADD_MID, GTLREF_ADD_END, GTLREF_DATA_MID, GTLREF_DATA_END, LL_ID[1:0], MS_ID[1:0], PECI, RESERVED, SKTOCC#, TESTHI[11:10], TESTHI[7:0], TESTIN1, TESTIN2, VCC, VCC_DIE_SENSE, VCC_DIE_SENSE2, VCCPLL, VID_SELECT, VSS_DIE_SENSE, VSS_DIE_SENSE2, VSS, VTT, VTT_OUT, VTT_SEL Notes: 1. Refer to Section 5 for signal descriptions. 2. These signals may be driven simultaneously by multiple agents (Wired-OR). 3. Not all Quad-Core Intel® Xeon® Processor 5300 Series support the additional signals A[37:36]#. Processors that support these signals will be outlined in the Quad-Core Intel® Xeon® Processor 5300 Series NDA Specification Update. Table 2-7 and Table 2-8 outline the signals which include on-die termination (RTT). Table 2-7 denotes AGTL+ signals, while Table 2-8 outlines non AGTL+ signals including open drain signals. Table 2-9 provides signal reference voltages. Table 2-7. AGTL+ Signal Description Table AGTL+ signals with RTT 1 A[37:3]# , ADS#, ADSTB[1:0]#, AP[1:0]#, BINIT#, BNR#, BPRI#, D[63:0]#, DBI[3:0]#, DBSY#, DEFER#, DP[3:0]#, DRDY#, DSTBN[3:0]#, DSTBP[3:0]#, HIT#, HITM#, LOCK#, MCERR#, REQ[4:0]#, RS[2:0]#, RSP#, TRDY# AGTL+ signals with no RTT BPM[5:0]#, BPMb[3:0]#, RESET#, BR[1:0]# Note: 1. Not all Quad-Core Intel® Xeon® Processor 5300 Series support the additional signals A[37:36]#. Processors that support these signals will be outlined in the Quad-Core Intel® Xeon® Processor 5300 Series NDA Specification Update. Table 2-8. Non AGTL+ Signal Description Table Signals with RTT FORCEPR#1, PROCHOT#1 Signals with no RTT A20M#, BCLK[1:0], BSEL[2:0], COMP[3:0], FERR#/ PBE#, GTLREF_ADD_MID, GTLREF_ADD_END, GTLREF_DATA_MID, GTLREF_DATA_END, IERR#, IGNNE#, INIT#, LINT0/INTR, LINT1/NMI, LL_ID[1:0], MS_ID[1:0], PECI, PWRGOOD, SKTOCC#, SMI#, STPCLK#, TCK, TDI, TDO, TESTHI[11:10], TESTHI[7:0], TESTIN1, TESTIN2, THERMTRIP#, TMS, TRST#, VCC_DIE_SENSE, VCC_DIE_SENSE2, VID[6:1], VID_SELECT, VSS_DIE_SENSE, VSS_DIE_SENSE2, VTT_SEL Note: 1. Signals that have a 50 Ω pullup to VTT on package. Table 2-9. Signal Reference Voltages GTLREF 1 A[37:3]# , ADS#, ADSTB[1:0]#, AP[1:0]#, BINIT#, BNR#, BPM[5:0]#, BPMb[3:0]#, BPRI#, BR[1:0]#, D[63:0]#, DBI[3:0]#, DBSY#, DEFER#, DP[3:0]#, DRDY#, DSTBN[3:0]#, DSTBP[3:0]#, HIT#, HITM#, LOCK#, MCERR#, RESET#, REQ[4:0]#, RS[2:0]#, RSP#, TRDY# Quad-Core Intel® Xeon® Processor 5300 Series Datasheet CMOS A20M#, FORCEPR#, IGNNE#, INIT#, LINT0/INTR, LINT1/NMI, PWRGOOD, SMI#, STPCLK#, TCK, TDI, TMS, TRST# 25 Electrical Specifications Note: 1. Not all Quad-Core Intel® Xeon® Processor 5300 Series support the additional signals A[37:36]#. Processors that support these signals will be outlined in the Quad-Core Intel® Xeon® Processor 5300 Series NDA Specification Update. 2.8 CMOS Asynchronous and Open Drain Asynchronous Signals Legacy input signals such as A20M#, IGNNE#, INIT#, SMI#, and STPCLK# utilize CMOS input buffers. Legacy output signals such as FERR#/PBE#, IERR#, PROCHOT#, and THERMTRIP# utilize open drain output buffers. All of the CMOS and Open Drain signals are required to be asserted/deasserted for at least eight BCLKs in order for the processor to recognize the proper signal state. See Section 2.13 for the DC specifications. See Section 7 for additional timing requirements for entering and leaving the low power states. 2.9 Test Access Port (TAP) Connection Due to the voltage levels supported by other components in the Test Access Port (TAP) logic, it is recommended that the processor(s) be first in the TAP chain and followed by any other components within the system. A translation buffer should be used to connect to the rest of the chain unless one of the other components is capable of accepting an input of the appropriate voltage. Similar considerations must be made for TCK, TDO, TMS, and TRST#. Two copies of each signal may be required with each driving a different voltage level. 2.10 Platform Environmental Control Interface (PECI) DC Specifications PECI is an Intel proprietary one-wire interface that provides a communication channel between Intel processor and external thermal monitoring devices. The Quad-Core Intel® Xeon® Processor 5300 Series contains Digital Thermal Sensors (DTS) distributed throughout the die. These sensors are implemented as analog-to-digital converters calibrated at the factor for reasonable accuracy to provide a digital representation of relative processor temperature. PECI provides an interface to relay the highest DTS temperature within a die to external management devices for thermal/ fan speed control. More detailed information may be found in the Platform Environment Control Interface (PECI) External Architecture Specification. 2.10.1 DC Characteristics A PECI device interface operates at a nominal voltage set by VTT. The set of DC electrical specifications shown in Table 2-10 is used with devices normally operating from a VTT interface supply. VTT nominal levels will vary between processor families. All PECI devices will operate at the VTT level determined by the processor installed in the system. For VTT specifications, refer to Table 2-12. Table 2-10. PECI DC Electrical Limits (Sheet 1 of 2) Symbol Vin Vhysteresis VN 26 Definition and Conditions Min Max Units Input Voltage Range -0.150 VTT V Hysteresis 0.1 * VTT N/A V Negative-edge threshold voltage 0.275 * VTT 0.500 * VTT V Notes1 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Electrical Specifications Table 2-10. PECI DC Electrical Limits (Sheet 2 of 2) Symbol Notes1 Definition and Conditions Min Max Units Vp Positive-edge threshold voltage 0.550 * VTT 0.725 * VTT V Isource High level output source -6.0 N/A mA 0.5 1.0 mA N/A 50 µA 2 N/A 10 µA 2 Bus capacitance per node N/A 10 pF 3 Signal noise immunity above 300 MHz 0.1 * VTT N/A Vp-p (VOH = 0.75 * VTT) Low level output sink Isink (VOL = 0.25 * VTT) Ileak+ High impedance state leakage to VTT (Vleak = VOL) Ileak- High impedance leakage to GND (Vleak = VOH) Cbus Vnoise Note: 1. VTT supplies the PECI interface. PECI behavior does not affect VTT min/max specifications. 2. The leakage specification applies to powered devices on the PECI bus. 3. One node is counted for each client and one node for the system host. Extended trace lengths might appear as additional nodes. 2.10.2 Input Device Hysteresis The input buffers in both client and host models must use a Schmitt-triggered input design for improved noise immunity. Use Figure 2-1 as a guide for input buffer design. Figure 2-1. Input Device Hysteresis VTT Maximum VP PECI High Range Minimum VP Minimum Hysteresis Valid Input Signal Range Maximum VN Minimum VN PECI Low Range PECI Ground 2.11 Mixing Processors Intel supports and validates dual processor configurations only in which both processors operate with the same FSB frequency, core frequency, number of cores, and have the same internal cache sizes. Mixing components operating at different internal clock frequencies is not supported and will not be validated by Intel. Combining processors from different power segments is also not supported. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 27 Electrical Specifications Note: Processors within a system must operate at the same frequency per bits [12:8] of the CLOCK_FLEX_MAX MSR; however this does not apply to frequency transitions initiated due to thermal events, Extended HALT, Enhanced Intel SpeedStep® Technology transitions, or assertion of the FORCEPR# signal. Not all operating systems can support dual processors with mixed frequencies. Mixing processors of different steppings but the same model (as per CPUID instruction) is supported. Details regarding the CPUID instruction are provided in the AP-485 Intel® Processor Identification and the CPUID Instruction application note. 2.12 Absolute Maximum and Minimum Ratings Table 2-11 specifies absolute maximum and minimum ratings only, which lie outside the functional limits of the processor. Only within specified operation limits, can functionality and long-term reliability be expected. At conditions outside functional operation condition limits, but within absolute maximum and minimum ratings, neither functionality nor long-term reliability can be expected. If a device is returned to conditions within functional operation limits after having been subjected to conditions outside these limits, but within the absolute maximum and minimum ratings, the device may be functional, but with its lifetime degraded depending on exposure to conditions exceeding the functional operation condition limits. At conditions exceeding absolute maximum and minimum ratings, neither functionality nor long-term reliability can be expected. Moreover, if a device is subjected to these conditions for any length of time then, when returned to conditions within the functional operating condition limits, it will either not function or its reliability will be severely degraded. Although the processor contains protective circuitry to resist damage from static electric discharge, precautions should always be taken to avoid high static voltages or electric fields. . Table 2-11. Processor Absolute Maximum Ratings Symbol Parameter Min Max Unit VCC Core voltage with respect to VSS -0.30 1.55 V VTT FSB termination voltage with respect to VSS -0.30 1.55 V TCASE Processor case temperature See Section 6 See Section 6 °C TSTORAGE Storage temperature -40 85 °C Notes1, 2 3, 4, 5 Notes: 1. For functional operation, all processor electrical, signal quality, mechanical and thermal specifications must be satisfied. 2. Overshoot and undershoot voltage guidelines for input, output, and I/O signals are outlined in Section 3. Excessive overshoot or undershoot on any signal will likely result in permanent damage to the processor. 3. Storage temperature is applicable to storage conditions only. In this scenario, the processor must not receive a clock, and no lands can be connected to a voltage bias. Storage within these limits will not affect the long-term reliability of the device. For functional operation, please refer to the processor case temperature specifications. 4. This rating applies to the processor and does not include any tray or packaging. 5. Failure to adhere to this specification can affect the long-term reliability of the processor. 28 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Electrical Specifications 2.13 Processor DC Specifications The processor DC specifications in this section are defined at the processor die (pads) unless noted otherwise. See Table 4-1 for the Quad-Core Intel® Xeon® Processor 5300 Series land listings and Table 5-1 for signal definitions. Voltage and current specifications are detailed in Table 2-12. For platform planning refer to Table 2-13, which provides VCC Static and Transient Tolerances. This same information is presented graphically in Figure 2-7, Figure 2-8 and Figure 2-9. The FSB clock signal group is detailed in Table 2-21. The DC specifications for the AGTL+ signals are listed in Table 2-16. Legacy signals and Test Access Port (TAP) signals follow DC specifications similar to GTL+. The DC specifications for the PWRGOOD input and TAP signal group are listed in Table 2-17. Table 2-12 through Table 2-18 list the DC specifications for the processor and are valid only while meeting specifications for case temperature (TCASE as specified in Section 6), clock frequency, and input voltages. Care should be taken to read all notes associated with each parameter. 2.13.1 Flexible Motherboard Guidelines (FMB) The Flexible Motherboard (FMB) guidelines are estimates of the maximum values the Quad-Core Intel® Xeon® Processor 5300 Series will have over certain time periods. The values are only estimates and actual specifications for future processors may differ. Processors may or may not have specifications equal to the FMB value in the foreseeable future. System designers should meet the FMB values to ensure their systems will be compatible with future processors. Table 2-12. Voltage and Current Specifications (Sheet 1 of 3) Symbol Parameter Min Typ Max Unit Notes 1,11 VID VID range for Quad-Core Intel® Xeon® Processor E5300 , QuadCore Intel® Xeon® Processor X5300 Series, and Quad-Core Intel® Xeon® Processor X5365 Series 1.0000 1.5000 V VID VID Range for Quad-Core Intel® Xeon® Processor L5300 Series 1.1000 1.2500 V VID VID Range for Quad-Core Intel® Xeon® Processor L5318 0.9000 1.2500 V VCC VCC for processor core Launch - FMB See Table 2-13, Figure 2-7, Figure 2-8 and Table 2-9 V 2, 3, 4, 6, 9 VCC_BOOT Default VCC Voltage for initial power up V 2 VVID_STEP VID step size during a transition VVID_SHIFT Total allowable DC load line shift from VID steps VTT FSB termination voltage (DC + AC specification) VCCPLL PLL supply voltage (DC + AC specification) ICC ICC for Quad-Core Intel® Xeon® Processor E5300 core with multiple VID Launch - FMB Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 1.10 ± 12.5 mV 450 mV 10 8,13 1.14 1.20 1.26 V 1.455 1.500 1.605 V 90 A 4,5,6,9 29 Electrical Specifications Table 2-12. Voltage and Current Specifications (Sheet 2 of 3) Symbol ICC_RESET ICC_RESET for Quad-Core Intel® Xeon® Processor E5300 core with multiple VID Launch - FMB ICC ICC for Quad-Core Intel® Xeon® Processor X5300 Series core with multiple VID Launch - FMB ICC_RESET ICC_RESET for Quad-Core Intel® Xeon® Processor X5300 Series core with multiple VID Launch - FMB ICC ICC for Quad-Core Intel® Xeon® Processor X5365 Series processor core with multiple VID Launch - FMB ICC_RESET ICC_RESET for Quad-Core Intel® Xeon® Processor X5365 Series processor core with multiple VID Launch - FMB ICC ICC for Quad-Core Intel® Xeon® Processor L5300 Series processor core with multiple VID Launch - FMB ICC_RESET ICC_RESET for Quad-Core Intel® Xeon® Processor L5300 Series processor core with multiple VID Launch - FMB ICC ICC for Quad-Core Intel® Xeon® Processor L5318 core with multiple VID Launch - FMB ICC_RESET ICC_RESET for Quad-Core Intel® Xeon® Processor L5318 core with multiple VID Launch - FMB ITT ICC for VTT supply before VCC stable ICC for VTT supply after VCC stable ICC_TDC Thermal Design Current (TDC) Quad-Core Intel® Xeon® Processor E5300 Launch - FMB ICC_TDC ICC_TDC ICC_TDC 30 Parameter Thermal Design Current (TDC) Quad-Core Intel® Xeon® Processor X5300 Series Launch - FMB Thermal Design Current (TDC) Quad-Core Intel® Xeon® Processor X5365 Series Launch - FMB Thermal Design Current (TDC) Quad-Core Intel® Xeon® Processor L5300 Series Launch - FMB Min Typ Max Unit Notes 1,11 90 A 17 125 A 4,5,6,9 125 A 17 150 A 4,5,6,9 150 A 17 60 A 4,5,6,9 60 A 17 50 A 4,5,6,9 50 A 17 8.0 A 15 7.0 A 70 A 6,14 110 A 6,14 130 A 6,14 50 A 6,14 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Electrical Specifications Table 2-12. Voltage and Current Specifications (Sheet 3 of 3) Symbol ICC_TDC Parameter Thermal Design Current (TDC) Quad-Core Intel® Xeon® Processor L5318 Launch - FMB Min Typ Max Unit Notes 1,11 45 A 6,14 580 mA 16 200 µA 7 260 mA 12 90 A ICC_VTT_OUT DC current that may be drawn from VTT_OUT per land ICC_GTLREF ICC for GTLREF_DATA_MID, GTLREF_DATA_END, GTLREF_ADD_MID, GTLREF_ADD_END ICC_VCCPLL ICC for PLL supply ITCC ICC for Quad-Core Intel® Xeon® Processor E5300 during active thermal control circuit (TCC) ITCC ICC for Quad-Core Intel® Xeon® Processor X5300 Series during active thermal control circuit (TCC) 125 A ITCC ICC for Quad-Core Intel® Xeon® Processor X5365 Series during active thermal control circuit (TCC) 150 A ITCC ICC for Quad-Core Intel® Xeon® Processor L5300 Series during active thermal control circuit (TCC) 60 A ITCC ICC for Quad-Core Intel® Xeon® Processor L5318 during active thermal control circuit (TCC) 50 A Notes: 1. Unless otherwise noted, all specifications in this table are based on final silicon characterization data. 2. These voltages are targets only. A variable voltage source should exist on systems in the event that a different voltage is required. See Section 2.5 for more information. 3. The voltage specification requirements are measured across the VCC_DIE_SENSE and VSS_DIE_SENSE lands and across the VCC_DIE_SENSE2 and VSS_DIE_SENSE2 lands with an oscilloscope set to 100 MHz bandwidth, 1.5 pF maximum probe capacitance, and 1 MΩ minimum impedance. The maximum length of ground wire on the probe should be less than 5 mm. Ensure external noise from the system is not coupled in the scope probe. 4. The processor must not be subjected to any static VCC level that exceeds the VCC_MAX associated with any particular current. Failure to adhere to this specification can shorten processor lifetime. 5. ICC_MAX specification is based on maximum VCC loadline Refer to Figure 2-12 for details. The processor is capable of drawing ICC_MAX for up to 10 ms. Refer to Figure 2-5, Figure 2-2, and Figure 2-3 for further details on the average processor current draw over various time durations. 6. FMB is the flexible motherboard guideline. These guidelines are for estimation purposes only. See Section 2.13.1 for further details on FMB guidelines. 7. This specification represents the total current for GTLREF_DATA_MID, GTLREF_DATA_END, GTLREF_ADD_MID, and GTLREF_ADD_END. 8. VTT must be provided via a separate voltage source and must not be connected to VCC. This specification is measured at the land. 9. Minimum VCC and maximum ICC are specified at the maximum processor case temperature (TCASE) shown in Figure 6-1. 10. This specification refers to the total reduction of the load line due to VID transitions below the specified VID. 11. Individual processor VID values may be calibrated during manufacturing such that two devices at the same frequency may have different VID settings. 12. This specification applies to the VCCPLL land. 13. Baseboard bandwidth is limited to 20 MHz. 14. ICC_TDC is the sustained (DC equivalent) current that the processor is capable of drawing indefinitely and should be used for the voltage regulator temperature assessment. The voltage regulator is responsible for monitoring its temperature and asserting the necessary signal to inform the processor of a thermal excursion. Please see the applicable design guidelines for further details. The processor is capable of drawing ICC_TDC indefinitely. Refer to Figure 2-2, Figure 2-3, and Figure 2-5,for further details on the average processor current draw over various time durations. This parameter is based on design characterization and is not tested. 15. This is the maximum total current drawn from the VTT plane by only one processor with RTT enabled. This specification does not include the current coming from on-board termination (RTT), through the signal line. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 31 Electrical Specifications Refer to the appropriate platform design guide and the Voltage Regulator Design Guidelines to determine the total ITT drawn by the system. This parameter is based on design characterization and is not tested. 16. ICC_VTT_OUT is specified at 1.2 V. 17. ICC_RESET is specified while PWRGOOD and RESET# are asserted. Refer to Table 2-26 for the PWRGOOD to RESET# de-assertion time specification and Table 2-23 for the RESET# Pulse Width specification . Figure 2-2. Quad-Core Intel® Xeon® Processor E5300 Series Load Current versus Time Sustained Current (A) 10 0 95 90 85 80 75 70 65 60 0 .0 1 0 .1 1 10 10 0 10 0 0 Tim e Duration (s) Notes: 1. Processor or voltage regulator thermal protection circuitry should not trip for load currents greater than ICC_TDC. 2. Not 100% tested. Specified by design characterization. Figure 2-3. Quad-Core Intel® Xeon® Processor X5300 Series and Load Current versus Time Sustained Current (A) 13 0 12 5 12 0 115 110 10 5 10 0 0 .0 1 0 .1 1 10 10 0 10 0 0 Tim e Duration (s) Notes: 1. Processor or voltage regulator thermal protection circuitry should not trip for load currents greater than ICC_TDC. 2. Not 100% tested. Specified by design characterization. 32 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Electrical Specifications Figure 2-4. Quad-Core Intel® Xeon® Processor X5365 Series Load Current versus Time Sustained Current (A) 160 155 150 145 140 135 130 125 120 0.01 0.1 1 10 100 1000 Time Duration (s) Notes: 1. Processor or voltage regulator thermal protection circuitry should not trip for load currents greater than ICC_TDC. 2. Not 100% tested. Specified by design characterization. Figure 2-5. Quad-Core Intel® Xeon® Processor L5300 Series Load Current versus Time 65 Sustained Current (A) 60 55 50 45 40 0.01 0.1 1 10 100 1 T im e Du r atio n (s ) Notes: 1. Processor or voltage regulator thermal protection circuitry should not trip for load currents greater than ICC_TDC. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 33 Electrical Specifications 2. Figure 2-6. Not 100% tested. Specified by design characterization. Quad-Core Intel® Xeon® Processor L5318 Load Current versus Time Notes: 1. Processor or voltage regulator thermal protection circuitry should not trip for load currents greater than ICC_TDC. 2. Not 100% tested. Specified by design characterization. Table 2-13. VCC Static and Transient Tolerance for Quad-Core Intel® Xeon® Processor E5300 Series, Quad-Core Intel® Xeon® Processor X5300 Series, Quad-Core Intel® Xeon® Processor L5300 Series (Sheet 1 of 2) ICC (A) 34 VCC_Max (V) VCC_Typ (V) VCC_Min (V) Notes 0 VID - 0.000 VID - 0.015 VID - 0.030 1, 2, 3 5 VID - 0.006 VID - 0.021 VID - 0.036 1, 2, 3 10 VID - 0.013 VID - 0.028 VID - 0.043 1, 2, 3 15 VID - 0.019 VID - 0.034 VID - 0.049 1, 2, 3 20 VID - 0.025 VID - 0.040 VID - 0.055 1, 2, 3 25 VID - 0.031 VID - 0.046 VID - 0.061 1, 2, 3 30 VID - 0.038 VID - 0.053 VID - 0.068 1, 2, 3 35 VID - 0.044 VID - 0.059 VID - 0.074 1, 2, 3 40 VID - 0.050 VID - 0.065 VID - 0.080 1, 2, 3 45 VID - 0.056 VID - 0.071 VID - 0.086 1, 2, 3 50 VID - 0.063 VID - 0.077 VID - 0.093 1, 2, 3 55 VID - 0.069 VID - 0.084 VID - 0.099 1, 2, 3 60 VID - 0.075 VID - 0.090 VID - 0.105 1, 2, 3 65 VID - 0.081 VID - 0.096 VID - 0.111 1, 2, 3, 4 70 VID - 0.087 VID - 0.103 VID - 0.118 1, 2, 3, 4 75 VID - 0.094 VID - 0.109 VID - 0.124 1, 2, 3, 4 80 VID - 0.100 VID - 0.115 VID - 0.130 1, 2, 3, 4 85 VID - 0.106 VID - 0.121 VID - 0.136 1, 2, 3, 4 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Electrical Specifications Table 2-13. VCC Static and Transient Tolerance for Quad-Core Intel® Xeon® Processor E5300 Series, Quad-Core Intel® Xeon® Processor X5300 Series, Quad-Core Intel® Xeon® Processor L5300 Series (Sheet 2 of 2) ICC (A) VCC_Max (V) VCC_Typ (V) VCC_Min (V) Notes 90 VID - 0.113 VID - 0.128 VID - 0.143 1, 2, 3, 4 95 VID - 0.119 VID - 0.134 VID - 0.149 1, 2, 3, 4 100 VID - 0.125 VID - 0.140 VID - 0.155 1, 2, 3, 4 105 VID - 0.131 VID - 0.146 VID - 0.161 1, 2, 3, 4 110 VID - 0.138 VID - 0.153 VID - 0.168 1, 2, 3, 4 115 VID - 0.144 VID - 0.159 VID - 0.174 1, 2, 3, 4 120 VID - 0.150 VID - 0.165 VID - 0.180 1, 2, 3, 4 125 VID - 0.156 VID - 0.171 VID - 0.186 1, 2, 3, 4 Notes: 1. The VCC_MIN and VCC_MAX loadlines represent static and transient limits. Please see Section 2.13.2 for VCC overshoot specifications. 2. This table is intended to aid in reading discrete points on Figure 2-7 for Quad-Core Intel® Xeon® Processor E5300 , Figure 2-8 for Quad-Core Intel® Xeon® Processor X5300 Series and Figure 2-9 for Quad-Core Intel® Xeon® Processor L5300 Series. 3. The loadlines specify voltage limits at the die measured at the VCC_DIE_SENSE and VSS_DIE_SENSE lands and across the VCC_DIE_SENSE2 and VSS_DIE_SENSE2 lands. Voltage regulation feedback for voltage regulator circuits must also be taken from processor VCC_DIE_SENSE and VSS_DIE_SENSE lands and VCC_DIE_SENSE2 and VSS_DIE_SENSE2 lands. Refer to the Voltage Regulator Module (VRM) and Enterprise Voltage Regulator Down (EVRD) 11.0 Design Guidelines for socket load line guidelines and VR implementation. Please refer to the appropriate platform design guide for details on VR implementation. 4. Icc values greater than 90 A and 60 A are not applicable for the Quad-Core Intel® Xeon® Processor E5300 and Quad-Core Intel® Xeon® Processor L5300 Series, respectively. Figure 2-7. Quad-Core Intel® Xeon® Processor E5300 Series VCC Static and Transient Tolerance Load Lines Icc [A] 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 VID - 0.000 VID - 0.020 VCC Maximum VID - 0.040 Vcc [V] VID - 0.060 VID - 0.080 VID - 0.100 VID - 0.120 VCC Typical VID - 0.140 VCC Minimum VID - 0.160 Notes: 1. The VCC_MIN and VCC_MAX loadlines represent static and transient limits. Please see Section 2.13.2 for VCC overshoot specifications. 2. Refer to Table 2-12 for processor VID information. 3. Refer to Table 2-13 for VCCStatic and Transient Tolerance Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 35 Electrical Specifications 4. Figure 2-8. The load lines specify voltage limits at the die measured at the VCC_DIE_SENSE and VSS_DIE_SENSE lands and the VCC_DIE_SENSE2 and VSS_DIE_SENSE2 lands. Voltage regulation feedback for voltage regulator circuits must also be taken from processor VCC_DIE_SENSE and VSS_DIE_SENSE lands and VCC_DIE_SENSE2 and VSS_DIE_SENSE2 lands. Refer to the Voltage Regulator Module (VRM) and Enterprise Voltage Regulator Down (EVRD) 11.0 Design Guidelines for socket load line guidelines and VR implementation. Please refer to the appropriate platform design guide for details on VR implementation. Quad-Core Intel® Xeon® Processor X5300 Series VCC Static and Transient Tolerance Load Lines Ic c [A ] 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 V ID - 0 .0 0 0 V ID - 0 .0 2 0 V ID - 0 .0 4 0 V CC M a x im u m V ID - 0 .0 6 0 Vcc [V] V ID - 0 .0 8 0 V ID - 0 .1 0 0 V ID - 0 .1 2 0 V ID - 0 .1 4 0 V CC T y p ic a l V ID - 0 .1 6 0 V ID - 0 .1 8 0 V CC M in im u m V ID - 0 .2 0 0 Notes: 1. The VCC_MIN and VCC_MAX loadlines represent static and transient limits. Please see Section 2.13.2 for VCC overshoot specifications. 2. Refer to Table 2-12 for processor VID information. 3. Refer to Table 2-13 for VCCStatic and Transient Tolerance 4. The load lines specify voltage limits at the die measured at the VCC_DIE_SENSE and VSS_DIE_SENSE lands and the VCC_DIE_SENSE2 and VSS_DIE_SENSE2 lands. Voltage regulation feedback for voltage regulator circuits must also be taken from processor VCC_DIE_SENSE and VSS_DIE_SENSE lands and VCC_DIE_SENSE2 and VSS_DIE_SENSE2 lands. Refer to the Voltage Regulator Module (VRM) and Enterprise Voltage Regulator Down (EVRD) 11.0 Design Guidelines for socket load line guidelines and VR implementation. Please refer to the appropriate platform design guide for details on VR implementation. 36 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Electrical Specifications Figure 2-9. Quad-Core Intel® Xeon® Processor L5300 Series VCC Static and Transient Tolerance Load Lines Icc [A] 0 5 10 15 20 25 30 35 40 45 50 55 60 VID - 0.000 VID - 0.010 VCC Maximum VID - 0.020 VID - 0.030 Vcc [V] VID - 0.040 VID - 0.050 VID - 0.060 VID - 0.070 VCC Typical VID - 0.080 VID - 0.090 VCC Minimum VID - 0.100 Notes: 1. 2. 3. 4. The VCC_MIN and VCC_MAX loadlines represent static and transient limits. Please see Section 2.13.2 for VCC overshoot specifications. Refer to Table 2-12 for processor VID information. Refer to Table 2-13 for VCCStatic and Transient Tolerance. The load lines specify voltage limits at the die measured at the VCC_DIE_SENSE and VSS_DIE_SENSE lands and the VCC_DIE_SENSE2 and VSS_DIE_SENSE2 lands. Voltage regulation feedback for voltage regulator circuits must also be taken from processor VCC_DIE_SENSE and VSS_DIE_SENSE lands and VCC_DIE_SENSE2 and VSS_DIE_SENSE2 lands. Refer to the Voltage Regulator Module (VRM) and Enterprise Voltage Regulator Down (EVRD) 11.0 Design Guidelines for socket load line guidelines and VR implementation. Please refer to the appropriate platform design guide for details on VR implementation Table 2-14. VCC Static and Transient Tolerance for Quad-Core Intel® Xeon® Processor X5365 Series (Sheet 1 of 2) ICC (A) VCC_Max (V) VCC_Typ (V) VCC_Min (V) Notes 0 VID - 0.000 VID - 0.010 VID - 0.020 5 VID - 0.006 VID - 0.016 VID - 0.026 1,2,3 10 VID - 0.013 VID - 0.023 VID - 0.033 1,2,3 15 VID - 0.019 VID - 0.029 VID - 0.039 1,2,3 20 VID - 0.025 VID - 0.035 VID - 0.045 1,2,3 25 VID - 0.031 VID - 0.041 VID - 0.051 1,2,3 30 VID - 0.038 VID - 0.048 VID - 0.058 1,2,3 35 VID - 0.044 VID - 0.054 VID - 0.064 1,2,3 40 VID - 0.050 VID - 0.060 VID - 0.070 1,2,3 45 VID - 0.056 VID - 0.066 VID - 0.076 1,2,3 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 1,2,3 37 Electrical Specifications Table 2-14. VCC Static and Transient Tolerance for Quad-Core Intel® Xeon® Processor X5365 Series (Sheet 2 of 2) ICC (A) VCC_Max (V) VCC_Typ (V) VCC_Min (V) Notes 50 VID - 0.063 VID - 0.073 VID - 0.083 1,2,3 55 VID - 0.069 VID - 0.079 VID - 0.089 1,2,3 60 VID - 0.075 VID - 0.085 VID - 0.095 1,2,3 65 VID - 0.081 VID - 0.091 VID - 0.101 1,2,3 70 VID - 0.087 VID - 0.097 VID - 0.108 1,2,3 75 VID - 0.094 VID - 0.104 VID - 0.114 1,2,3 80 VID - 0.100 VID - 0.110 VID - 0.120 1,2,3 85 VID - 0.106 VID - 0.116 VID - 0.126 1,2,3 90 VID - 0.113 VID - 0.123 VID - 0.133 1,2,3 95 VID - 0.119 VID - 0.129 VID - 0.139 1,2,3 100 VID - 0.125 VID - 0.135 VID - 0.145 1,2,3 105 VID - 0.131 VID - 0.141 VID - 0.151 1,2,3 110 VID - 0.138 VID - 0.148 VID - 0.158 1,2,3 115 VID - 0.144 VID - 0.154 VID - 0.164 1,2,3 120 VID - 0.150 VID - 0.160 VID - 0.170 1,2,3 125 VID - 0.156 VID - 0.166 VID - 0.176 1,2,3 130 VID - 0.163 VID - 0.173 VID - 0.183 1,2,3 135 VID - 0.169 VID - 0.179 VID - 0.189 1,2,3 140 VID - 0.175 VID - 0.185 VID - 0.195 1,2,3 145 VID - 0.181 VID - 0.191 VID - 0.201 1,2,3 150 VID - 0.188 VID - 0.198 VID - 0.208 1,2,3 Notes: 1. The VCC_MIN and VCC_MAX loadlines represent static and transient limits. Please see Section 2.13.2 for VCC overshoot specifications. 2. This table is intended to aid in reading discrete points on Figure 2-10 for Quad-Core Intel® Xeon® Processor X5365 Series 3. The loadlines specify voltage limits at the die measured at the VCC_DIE_SENSE and VSS_DIE_SENSE lands and across the VCC_DIE_SENSE2 and VSS_DIE_SENSE2 lands. Voltage regulation feedback for voltage regulator circuits must also be taken from processor VCC_DIE_SENSE and VSS_DIE_SENSE lands and VCC_DIE_SENSE2 and VSS_DIE_SENSE2 lands. Refer to the Voltage Regulator Module (VRM) and Enterprise Voltage Regulator Down (EVRD) 11.0 Design Guidelines for socket load line guidelines and VR implementation. Please refer to the appropriate platform design guide for details on VR implementation. 38 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Electrical Specifications Figure 2-10. Quad-Core Intel® Xeon® Processor X5365 Series VCC Static and Transient Tolerance Load Lines Icc [A] 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 VID - 0.000 VCC Maximum VID - 0.050 Vcc [V] VID - 0.100 VID - 0.150 VCC Typical VID - 0.200 VCC Minimum VID - 0.250 Notes: 1. The VCC_MIN and VCC_MAX loadlines represent static and transient limits. Please see Section 2.13.2 for VCC overshoot specifications. 2. Refer to Table 2-12 for processor VID information. 3. Refer to Table 2-14 for VCCStatic and Transient Tolerance. 4. The load lines specify voltage limits at the die measured at the VCC_DIE_SENSE and VSS_DIE_SENSE lands and the VCC_DIE_SENSE2 and VSS_DIE_SENSE2 lands. Voltage regulation feedback for voltage regulator circuits must also be taken from processor VCC_DIE_SENSE and VSS_DIE_SENSE lands and VCC_DIE_SENSE2 and VSS_DIE_SENSE2 lands. Refer to the Voltage Regulator Module (VRM) and Enterprise Voltage Regulator Down (EVRD) 11.0 Design Guidelines for socket load line guidelines and VR implementation. Please refer to the appropriate platform design guide for details on VR implementation Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 39 Electrical Specifications Table 2-15. VCC Static and Transient Tolerance for Quad-Core Intel® Xeon® Processor L5318 Series ICC (A) VCC_Max (V) VCC_Typ (V) VCC_Min (V) Notes 0 VID - 0.000 VID - 0.015 VID - 0.030 1,2,3 5 VID - 0.005 VID - 0.020 VID - 0.035 1,2,3 10 VID - 0.010 VID - 0.025 VID - 0.040 1,2,3 15 VID - 0.015 VID - 0.030 VID - 0.045 1,2,3 20 VID - 0.020 VID - 0.035 VID - 0.050 1,2,3 25 VID - 0.025 VID - 0.040 VID - 0.055 1,2,3 30 VID - 0.030 VID - 0.045 VID - 0.060 1,2,3 35 VID - 0.035 VID - 0.050 VID - 0.065 1,2,3 40 VID - 0.040 VID - 0.055 VID - 0.070 1,2,3 45 VID - 0.045 VID - 0.060 VID - 0.075 1,2,3 50 VID - 0.050 VID - 0.065 VID - 0.080 1,2,3 55 VID - 0.055 VID - 0.070 VID - 0.085 1,2,3 60 VID - 0.060 VID - 0.075 VID - 0.090 1,2,3 Notes: 1. The VCC_MIN and VCC_MAX loadlines represent static and transient limits. Please see Section 2.13.2 for VCC overshoot specifications. 2. This table is intended to aid in reading discrete points on Figure 2-11 for Quad-Core Intel® Xeon® Processor L5318 3. The loadlines specify voltage limits at the die measured at the VCC_DIE_SENSE and VSS_DIE_SENSE lands and across the VCC_DIE_SENSE2 and VSS_DIE_SENSE2 lands. Voltage regulation feedback for voltage regulator circuits must also be taken from processor VCC_DIE_SENSE and VSS_DIE_SENSE lands and VCC_DIE_SENSE2 and VSS_DIE_SENSE2 lands. Refer to the Voltage Regulator Module (VRM) and Enterprise Voltage Regulator Down (EVRD) 11.0 Design Guidelines for socket load line guidelines and VR implementation. Please refer to the appropriate platform design guide for details on VR implementation. 40 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Electrical Specifications Figure 2-11. Quad-Core Intel® Xeon® Processor L5318 VCC Static and Transient Tolerance Load Lines Notes: 1. 2. 3. 4. The VCC_MIN and VCC_MAX loadlines represent static and transient limits. Please see Section 2.13.2 for VCC overshoot specifications. Refer to Table 2-12 for processor VID information. Refer to Table 2-15 for VCCStatic and Transient Tolerance. The load lines specify voltage limits at the die measured at the VCC_DIE_SENSE and VSS_DIE_SENSE lands and the VCC_DIE_SENSE2 and VSS_DIE_SENSE2 lands. Voltage regulation feedback for voltage regulator circuits must also be taken from processor VCC_DIE_SENSE and VSS_DIE_SENSE lands and VCC_DIE_SENSE2 and VSS_DIE_SENSE2 lands. Refer to the Voltage Regulator Module (VRM) and Enterprise Voltage Regulator Down (EVRD) 11.0 Design Guidelines for socket load line guidelines and VR implementation. Please refer to the appropriate platform design guide for details on VR implementation. Table 2-16. AGTL+ Signal Group Specifications Symbol Parameter Min Typ Max Units Notes1 VIL Input Low Voltage -0.10 0 GTLREF-0.10 V 2,4,6 VIH Input High Voltage GTLREF+0.10 VTT VTT+0.10 V 3,6 VOH Output High Voltage VTT - 0.10 N/A VTT V 4,6 RON Buffer On Resistance 10.00 11.50 13.00 Ω 5 ILI Input Leakage Current N/A N/A ± 200 μA 7,8 Notes: 1. Unless otherwise noted, all specifications in this table apply to all processor frequencies. 2. VIL is defined as the maximum voltage level at a receiving agent that will be interpreted as a logical low value. 3. VIH is defined as the minimum voltage level at a receiving agent that will be interpreted as a logical high value. 4. VIH and VOH may experience excursions above VTT. However, input signal drivers must comply with the signal quality specifications. 5. This is the pull down driver resistance. Refer to processor I/O Buffer Models for I/V characteristics. Measured at 0.31*VTT. RON (min) = 0.225*RTT. RON (typ) = 0.250*RTT. RON (max) = 0.275*RTT. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 41 Electrical Specifications 6. 7. 8. GTLREF should be generated from VTT with a 1% tolerance resistor divider. The VTT referred to in these specifications is the instantaneous VTT. Specified when on-die RTT and RON are turned off. VIN between 0 and VTT. This is the measurement at the pin. Table 2-17. CMOS Signal Input/Output Group and TAP Signal Group DC Specifications Symbol Parameter Min Typ Max Units Notes1 VIL Input Low Voltage -0.10 0.00 0.3*VTT V 2,3 VIH Input High Voltage 0.7*VTT VTT VTT+0.1 V 2 VOL Output Low Voltage -0.10 0 0.1*VTT V 2 VOH Output High Voltage 0.9*VTT VTT VTT+0.1 V 2 IOL Output Low Current 1.70 N/A 4.70 mA 4 IOH Output High Current 1.70 N/A 4.70 mA 5 ILI Input Leakage Current N/A N/A ± 200 μA 6,7 Notes: 1. Unless otherwise noted, all specifications in this table apply to all processor frequencies. 2. The VTT referred to in these specifications refers to instantaneous VTT. 3. Refer to the processor I/O Buffer Models for I/V characteristics. 4. Measured at 0.1*VTT. 5. Measured at 0.9*VTT. 6. For Vin between 0 V and VTT. Measured when the driver is tristated. 7. This is the measurement at the pin. Table 2-18. Open Drain Output Signal Group DC Specifications Symbol Parameter Min VOL Output Low Voltage VOH Output High Voltage IOL Output Low Current 16 ILO Leakage Current N/A Typ 0.95 * VTT Max Units Notes1 N/A 0.20 V VTT 1.05 * VTT V N/A 50 mA 2 N/A ± 400 μA 4,5 3 Notes: 1. Unless otherwise noted, all specifications in this table apply to all processor frequencies. 2. Measured at 0.2*VTT. 3. VOH is determined by value of the external pullup resistor to VTT. Please refer to platform design guide for details. 4. For VIN between 0 V and VOH. 5. This is the measurement at the pin. 2.13.2 VCC Overshoot Specification Processors can tolerate short transient overshoot events where VCC exceeds the VID voltage when transitioning from a high-to-low current load condition. This overshoot cannot exceed VID + VOS_MAX (VOS_MAX is the maximum allowable overshoot above VID). These specifications apply to the processor die voltage as measured across the VCC_DIE_SENSE and VSS_DIE_SENSE lands and across the VCC_DIE_SENSE2 and VSS_DIE_SENSE2 lands. Table 2-19. VCC Overshoot Specifications Symbol 42 Parameter Min Max Units Figure VOS_MAX Magnitude of VCC overshoot above VID 50 mV 2-12 TOS_MAX Time duration of VCC overshoot above VID 25 µs 2-12 Notes Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Electrical Specifications Figure 2-12. VCC Overshoot Example Waveform Example Overshoot Waveform VOS Voltage [V] VID + 0.050 VID - 0.000 TOS 0 5 10 15 20 25 Time [us] TOS: Overshoot time above VID VOS: Overshoot above VID Notes: 1. VOS is the measured overshoot voltage. 2. TOS is the measured time duration above VID. 2.13.3 Die Voltage Validation Core voltage (VCC) overshoot events at the processor must meet the specifications in Table 2-19 when measured across the VCC_DIE_SENSE and VSS_DIE_SENSE lands and across the VCC_DIE_SENSE2 and VSS_DIE_SENSE2 lands. Overshoot events that are < 10 ns in duration may be ignored. These measurements of processor die level overshoot should be taken with a 100 MHz bandwidth limited oscilloscope. 2.14 AGTL+ FSB Specifications Routing topologies are dependent on the processors supported and the chipset used in the design. Please refer to the appropriate platform design guidelines for specific implementation details. In most cases, termination resistors are not required as these are integrated into the processor silicon. See Table 2-7 for details on which signals do not include on-die termination. Please refer to Table 2-20 for RTT values. Valid high and low levels are determined by the input buffers via comparing with a reference voltage called GTLREF_DATA_MID, GTLREF_DATA_END, GTLREF_ADD_MID, and GTLREF_ADD_END. GTLREF_DATA_MID and GTLREF_DATA_END are the reference voltage for the FSB 4X data signals, GTLREF_ADD_MID and GTLREF_ADD_END are the reference voltage for the FSB 2X address signals and common clock signals. Table 2-20 lists the GTLREF_DATA_MID, GTLREF_DATA_END, GTLREF_ADD_MID, and GTLREF_ADD_END specifications. The AGTL+ reference voltages (GTLREF_DATA_MID, GTLREF_DATA_END, GTLREF_ADD_MID, and GTLREF_ADD_END) must be generated on the baseboard using high precision voltage divider circuits. Refer to the appropriate platform design guidelines for implementation details. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 43 Electrical Specifications Table 2-20. AGTL+ Bus Voltage Definitions Symbol Parameter Min Typ Max Unit Notes1 GTLREF_DATA_MID GTLREF_DATA_END Data Bus Reference Voltage 0.98 * 0.67 * VTT 0.67 * VTT 1.02 * 0.67 * VTT V 2, 3 GTLREF_ADD_MID GTLREF_ADD_END Address Bus Reference Voltage 0.98 * 0.67 * VTT 0.67 * VTT 1.02 * 0.67 * VTT V 2, 3 RTT Termination Resistance (pull up) 45 50 55 Ω 4 COMP Resistance 49.4 49.9 50.4 Ω 5 COMP Note: 1. Unless otherwise noted, all specifications in this table apply to all processor frequencies. 2. The tolerances for this specification have been stated generically to enable system designer to calculate the minimum values across the range of VTT. 3. GTLREF_DATA_MID, GTLREF_DATA_END, GTLREF_ADD_MID, and GTLREF_ADD_END is generated from VTT on the baseboard by a voltage divider of 1% resistors. The minimum and maximum specifications account for this resistor tolerance. Refer to the appropriate platform design guidelines for implementation details. The VTT referred to in these specifications is the instantaneous VTT. 4. RTT is the on-die termination resistance measured at VOL of the AGTL+ output driver. Measured at 0.31*VTT. RTT is connected to VTT on die. Refer to processor I/O Buffer Models for I/V characteristics. 5. COMP resistance must be provided on the system board with +/- 1% resistors. See the applicable platform design guide for implementation details. Table 2-21. FSB Differential BCLK Specifications Symbol Notes Parameter Min Typ Max Unit Figure VL Input Low Voltage -0.150 0.0 N/A V 2-15 VH Input High Voltage 0.660 0.710 0.850 V 2-15 VCROSS(abs) Absolute Crossing Point 0.250 0.350 0.550 V 2-15, 2-16 3,9 VCROSS(rel) Relative Crossing Point 0.250 + 0.5 * (VHavg - 0.700) N/A 0.550 + 0.5 * (VHavg - 0.700) V 2-15, 2-16 4,9,10 Δ VCROSS Range of Crossing Points N/A N/A 0.140 V 2-15, 2-16 12 1,2 VOS Overshoot N/A N/A VH + 0.300 V 2-15 5 VUS Undershoot -0.300 N/A N/A V 2-15 6 VRBM Ringback Margin 0.200 N/A N/A V 2-15 7 VTR Threshold Region VCROSS - 0.100 N/A VCROSS + 0.100 V 2-15 8 ILI Input Leakage Current N/A N/A +/- 100 μA 11 Note: 1. Unless otherwise noted, all specifications in this table apply to all processor frequencies. 2. Rise and fall times are measured single-ended between 245 mV and 455 mV of the clock swing. 3. Crossing Voltage is defined as the instantaneous voltage value when the rising edge of BCLK0 is equal to the falling edge of BCLK1. 4. VHavg is the statistical average of the VH measured by the oscilloscope. 5. Overshoot is defined as the absolute value of the maximum voltage. 6. Undershoot is defined as the absolute value of the minimum voltage. 44 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Electrical Specifications 7. Ringback Margin is defined as the absolute voltage difference between the maximum Rising Edge Ringback and the maximum Falling Edge Ringback. 8. Threshold Region is defined as a region entered around the crossing point voltage in which the differential receiver switches. It includes input threshold hysteresis. 9. The crossing point must meet the absolute and relative crossing point specifications simultaneously. 10. VHavg can be measured directly using “Vtop” on Agilent and “High” on Tektronix oscilloscopes. 11. For VIN between 0 V and VH. 12. ΔVCROSS is defined as the total variation of all crossing voltages as defined in Note 3. Figure 2-13. Electrical Test Circuit Figure 2-14. TCK Clock Waveform V2 TCK V3 V1 Tp Tp = T55: Period V1, V2: For rise and fall times, TCK is measured between 20% and 80% points on the waveform. V3: TCK is referenced to 0.5 * VTT Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 45 Electrical Specifications Figure 2-15. Differential Clock Waveform Overshoot BCLK1 VH Rising Edge Ringback Crossing Voltage Threshold Region Crossing Voltage Ringback Margin Falling Edge Ringback, BCLK0 VL Undershoot Tp Tp = T1: BCLK[1:0] period Figure 2-16. Differential Clock Crosspoint Specification 650 Crossing Point (mV) 600 550 550 mV 500 450 550 + 0.5 (VHavg - 700) 400 250 + 0.5 (VHavg - 700) 350 300 250 250 mV 200 660 670 680 690 700 710 720 730 740 750 760 770 780 790 800 810 820 830 840 850 VHavg (mV) § 46 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Mechanical Specifications 3 Mechanical Specifications The Quad-Core Intel® Xeon® Processor 5300 Series are packaged in a Flip Chip Land Grid Array (FC-LGA6) package that interfaces to the baseboard via a LGA771 socket. The package consists of two processor dies mounted on a pinless substrate with 771 lands. An integrated heat spreader (IHS) is attached to the package substrate and core and serves as the interface for processor component thermal solutions such as a heatsink. Figure 3-1 shows a sketch of the processor package components and how they are assembled together. Refer to the LGA771 Socket Design Guidelines for complete details on the LGA771 socket. The package components shown in Figure 3-1 include the following: • Integrated Heat Spreader (IHS) • Thermal Interface Material (TIM) • Processor Die • Package Substrate • Landside capacitors • Package Lands Figure 3-1. Processor Package Assembly Sketch IHS Core (die) TIM Substrate Package Lands Capacitors LGA771 Socket System Board Note: 3.1 This drawing is not to scale and is for reference only. Package Mechanical Drawings The package mechanical drawings are shown in Figure 3-2 through Figure 3-4. The drawings include dimensions necessary to design a thermal solution for the processor including: • Package reference and tolerance dimensions (total height, length, width, and so forth) • IHS parallelism and tilt • Land dimensions • Top-side and back-side component keepout dimensions • Reference datums Note: All drawing dimensions are in mm [in.]. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 47 Mechanical Specifications Figure 3-2. Note: 48 Processor Package Drawing (Sheet 1 of 3) Guidelines on potential IHS flatness variation with socket load plate actuation and installation of the cooling solution is available in the processor Thermal/Mechanical Design Guidelines. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Mechanical Specifications Figure 3-3. Processor Package Drawing (Sheet 2 of 3) Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 49 Mechanical Specifications Figure 3-4. 50 Processor Package Drawing (Sheet 3 of 3) Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Mechanical Specifications 3.2 Processor Component Keepout Zones The processor may contain components on the substrate that define component keepout zone requirements. A thermal and mechanical solution design must not intrude into the required keepout zones. Decoupling capacitors are typically mounted to either the topside or landside of the package substrate. See Figure 3-4 for keepout zones. 3.3 Package Loading Specifications Table 3-1 provides dynamic and static load specifications for the processor package. These mechanical load limits should not be exceeded during heatsink assembly, mechanical stress testing or standard drop and shipping conditions. The heatsink attach solutions must not include continuous stress onto the processor with the exception of a uniform load to maintain the heatsink-to-processor thermal interface. Also, any mechanical system or component testing should not exceed these limits. The processor package substrate should not be used as a mechanical reference or loadbearing surface for thermal or mechanical solutions. Table 3-1. Package Loading Specifications Parameter Static Compressive Load Dynamic Compressive Load Board Thickness Min Max Unit Notes 1.57 mm 0.062” 80 18 311 70 N lbf 1,2,3,9 2.16 mm 0.085” 111 25 311 70 N lbf 2.54 mm 0.100” 133 30 311 70 N lbf NA NA 311 N (max static compressive load) + 222 N dynamic loading N 70 lbf (max static compressive load) + 50 lbf dynamic loading Transient Bend Limits 1.57 mm 0.062” NA 750 1,3,4,5,6 lbf me 1,3,7,8 Notes: 1. These specifications apply to uniform compressive loading in a direction perpendicular to the IHS top surface. 2. This is the minimum and maximum static force that can be applied by the heatsink and retention solution to maintain the heatsink and processor interface. 3. These specifications are based on limited testing for design characterization. Loading limits are for the LGA771 socket. 4. Dynamic compressive load applies to all board thickness. 5. Dynamic loading is defined as an 11 ms duration average load superimposed on the static load requirement. 6. Test condition used a heatsink mass of 1 lbm with 50 g acceleration measured at heatsink mass. The dynamic portion of this specification in the product application can have flexibility in specific values, but the ultimate product of mass times acceleration should not exceed this dynamic load. 7. Transient bend is defined as the transient board deflection during manufacturing such as board assembly and system integration. It is a relatively slow bending event compared to shock and vibration tests. 8. For more information on the transient bend limits, please refer to the MAS document entitled Manufacturing with Intel® Components using 771-land LGA Package that Interfaces with the Motherboard via a LGA771 Socket. 9. Refer to the Quad-Core Intel® Xeon® Processor 5300 Series Thermal/Mechanical Design Guidelines for information on heatsink clip load metrology. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 51 Mechanical Specifications 3.4 Package Handling Guidelines Table 3-2 includes a list of guidelines on a package handling in terms of recommended maximum loading on the processor IHS relative to a fixed substrate. These package handling loads may be experienced during heatsink removal. Table 3-2. Package Handling Guidelines Parameter Maximum Recommended Units Notes Shear 311 70 N lbf 1,4,5 Tensile 111 25 N lbf 2,4,5 Torque 3.95 35 N-m LBF-in 3,4,5 Notes: 1. A shear load is defined as a load applied to the IHS in a direction parallel to the IHS top surface. 2. A tensile load is defined as a pulling load applied to the IHS in a direction normal to the IHS surface. 3. A torque load is defined as a twisting load applied to the IHS in an axis of rotation normal to the IHS top surface. 4. These guidelines are based on limited testing for design characterization and incidental applications (one time only). 5. Handling guidelines are for the package only and do not include the limits of the processor socket. 3.5 Package Insertion Specifications The Quad-Core Intel® Xeon® Processor 5300 Series can be inserted and removed 15 times from an LGA771 socket, which meets the criteria outlined in the LGA771 Socket Design Guidelines. 3.6 Processor Mass Specifications The typical mass of the Quad-Core Intel® Xeon® Processor 5300 Series is 21.5 g (0.76 oz). This includes all components which make up the entire processor product. 3.7 Processor Materials The Quad-Core Intel® Xeon® Processor 5300 Series are assembled from several components. The basic material properties are described in Table 3-3. Table 3-3. Processor Materials Component 52 Material Integrated Heat Spreader (IHS) Nickel over copper Substrate Fiber-reinforced resin Substrate Lands Gold over nickel Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Mechanical Specifications 3.8 Processor Markings Figure 3-5 shows the topside markings on the processor. This diagram aids in the identification of the Quad-Core Intel® Xeon® Processor 5300 Series. Figure 3-5. Processor Top-side Markings (Example) GROUP1LINE1 GROUP1LINE2 GROUP1LINE3 GROUP1LINE4 GROUP1LINE5 LOT ATPO NO S/N S/N Legend: Mark Text (Production Mark): GROUP1LINE1 GROUP1LINE2 GROUP1LINE3 GROUP1LINE4 GROUP1LINE5 2.66GHZ/8M/1333 Intel ® Xeon® SXXX XXXXX i (M) © ’05 x53XX (FPO) Legend: Mark Text (Engineering Mark): GROUP1LINE1 GROUP1LINE2 GROUP1LINE3 GROUP1LINE4 GROUP1LINE5 INTEL CONFIDENTIAL QXXX ES XXXXX i (M) © ‘05 HH80563KJ0678M (FPO) e4 Notes: 1. 2D matrix is required for engineering samples only (encoded with ATPO-S/N) 3.9 Processor Land Coordinates Figure 3-6 and Figure 3-7 show the top and bottom view of the processor land coordinates, respectively. The coordinates are referred to throughout the document to identify processor lands. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 53 Mechanical Specifications Figure 3-6. Processor Land Coordinates, Top View VCC / VSS 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 6 5 4 3 2 1 AN AM AL AN AM AL AK AJ AH AK AJ AH AG AF AE AG AF AE AD AC AD AC AB AA Y AB AA Y Socket 771 Quadrants Top View W V U T R P W V U T R P N M L N M L K J H K J H G F G F E D C E D C B A B A 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 VTT / Clocks 54 8 7 8 7 6 5 4 3 Address / Common Clock / Async 2 1 Data Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Mechanical Specifications Figure 3-7. Processor Land Coordinates, Bottom View VCC / VSS 1 Address / Common Clock / Async 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 AN AM AL AK AJ AH AG AF AE AD AC AB AA Y W V U T R P N M L K J H G F E D C B A AN AM AL AK AJ AH AG AF AE AD AC AB AA Y W V U T R P N M L K J H G F E D C B A Socket 771 Quadrants Bottom View 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Data VTT / Clocks § Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 55 Mechanical Specifications 56 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Land Listing 4 Land Listing 4.1 Quad-Core Intel® Xeon® Processor 5300 Series Pin Assignments This section provides sorted land list in Table 4-1 and Table 4-2. Table 4-1 is a listing of all processor lands ordered alphabetically by land name. Table 4-2 is a listing of all processor lands ordered by land number. 4.1.1 Land Listing by Land Name Table 4-1. Land Listing by Land Name (Sheet 1 of 23) Pin Name Pin No. Signal Buffer Type Direction Table 4-1. Land Listing by Land Name (Sheet 2 of 23) Pin Name Pin No. Signal Buffer Type Direction A03# M5 Source Sync Input/ Output A20M# K3 CMOS Asynchronous Input A04# P6 Source Sync Input/ Output A21# AA4 Source Sync Input/ Output A05# L5 Source Sync Input/ Output A22# AD6 Source Sync Input/ Output A06# L4 Source Sync Input/ Output A23# AA5 Source Sync Input/ Output A07# M4 Source Sync Input/ Output A24# AB5 Source Sync Input/ Output A08# R4 Source Sync Input/ Output A25# AC5 Source Sync Input/ Output A09# T5 Source Sync Input/ Output A26# AB4 Source Sync Input/ Output A10# U6 Source Sync Input/ Output A27# AF5 Source Sync Input/ Output A11# T4 Source Sync Input/ Output A28# AF4 Source Sync Input/ Output A12# U5 Source Sync Input/ Output A29# AG6 Source Sync Input/ Output A13# U4 Source Sync Input/ Output A30# AG4 Source Sync Input/ Output A14# V5 Source Sync Input/ Output A31# AG5 Source Sync Input/ Output A15# V4 Source Sync Input/ Output A32# AH4 Source Sync Input/ Output A16# W5 Source Sync Input/ Output A33# AH5 Source Sync Input/ Output A17# AB6 Source Sync Input/ Output A34# AJ5 Source Sync Input/ Output A18# W6 Source Sync Input/ Output A35# AJ6 Source Sync Input/ Output A19# Y6 Source Sync Input/ Output A36# N4 Source Sync Input/ Output A20# Y4 Source Sync Input/ Output A37# P5 Source Sync Input/ Output Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 57 Land Listing Table 4-1. Land Listing by Land Name (Sheet 3 of 23) Pin Name Pin No. Signal Buffer Type Direction Table 4-1. Land Listing by Land Name (Sheet 4 of 23) Pin Name Pin No. Signal Buffer Type Direction ADS# D2 Common Clk Input/ Output D01# C5 Source Sync Input/ Output ADSTB0# R6 Source Sync Input/ Output D02# A4 Source Sync Input/ Output ADSTB1# AD5 Source Sync Input/ Output D03# C6 Source Sync Input/ Output AP0# U2 Common Clk Input/ Output D04# A5 Source Sync Input/ Output AP1# U3 Common Clk Input/ Output D05# B6 Source Sync Input/ Output BCLK0 F28 Clk Input D06# B7 Source Sync BCLK1 G28 Clk Input Input/ Output BINIT# AD3 Common Clk Input/ Output D07# A7 Source Sync Input/ Output BNR# C2 Common Clk Input/ Output D08# A10 Source Sync Input/ Output BPM0# AJ2 Common Clk Input/ Output D09# A11 Source Sync Input/ Output BPM1# AJ1 Common Clk Output D10# B10 Source Sync Input/ Output BPM2# AD2 Common Clk Output D11# C11 Source Sync BPM3# AG2 Common Clk Input/ Output Input/ Output D12# D8 Source Sync BPM4# AF2 Common Clk Output Input/ Output BPM5# AG3 Common Clk Input/ Output D13# B12 Source Sync Input/ Output BPMb0# G1 Common Clk Input/ Output D14# C12 Source Sync Input/ Output BPMb1# C9 Common Clk Output D15# D11 Source Sync Input/ Output D16# G9 Source Sync Input/ Output D17# F8 Source Sync Input/ Output BPMb2# G4 Common Clk Output BPMb3# G3 Common Clk Input/ Output BPRI# G8 Common Clk Input BR0# F3 Common Clk Input/ Output D18# F9 Source Sync Input/ Output BR1# H5 Common Clk Input D19# E9 Source Sync BSEL0 G29 CMOS Asynchronous Output Input/ Output D20# D7 Source Sync BSEL1 H30 CMOS Asynchronous Output Input/ Output D21# E10 Source Sync BSEL2 G30 CMOS Asynchronous Output Input/ Output D22# D10 Source Sync COMP0 A13 Power/Other Input Input/ Output COMP1 T1 Power/Other Input D23# F11 Source Sync Input/ Output COMP2 G2 Power/Other Input D24# F12 Source Sync COMP3 R1 Power/Other Input Input/ Output D00# B4 Source Sync Input/ Output D25# D13 Source Sync Input/ Output D26# E13 Source Sync Input/ Output 58 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Land Listing Table 4-1. Land Listing by Land Name (Sheet 5 of 23) Pin Name Pin No. Signal Buffer Type Direction Table 4-1. Land Listing by Land Name (Sheet 6 of 23) Pin Name Pin No. Signal Buffer Type Direction D27# G13 Source Sync Input/ Output D53# B15 Source Sync Input/ Output D28# F14 Source Sync Input/ Output D54# C18 Source Sync Input/ Output D29# G14 Source Sync Input/ Output D55# B16 Source Sync Input/ Output D30# F15 Source Sync Input/ Output D56# A17 Source Sync Input/ Output D31# G15 Source Sync Input/ Output D57# B18 Source Sync Input/ Output D32# G16 Source Sync Input/ Output D58# C21 Source Sync Input/ Output D33# E15 Source Sync Input/ Output D59# B21 Source Sync Input/ Output D34# E16 Source Sync Input/ Output D60# B19 Source Sync Input/ Output D35# G18 Source Sync Input/ Output D61# A19 Source Sync Input/ Output D36# G17 Source Sync Input/ Output D62# A22 Source Sync Input/ Output D37# F17 Source Sync Input/ Output D63# B22 Source Sync Input/ Output D38# F18 Source Sync Input/ Output DBI0# A8 Source Sync Input/ Output D39# E18 Source Sync Input/ Output DBI1# G11 Source Sync Input/ Output D40# E19 Source Sync Input/ Output DBI2# D19 Source Sync Input/ Output D41# F20 Source Sync Input/ Output DBI3# C20 Source Sync Input/ Output D42# E21 Source Sync Input/ Output DBR# AC2 Power/Other Output DBSY# B2 Common Clk Input/ Output DEFER# G7 Common Clk Input DP0# J16 Common Clk Input/ Output D43# F21 Source Sync Input/ Output D44# G21 Source Sync Input/ Output D45# E22 Source Sync Input/ Output DP1# H15 Common Clk D46# D22 Source Sync Input/ Output Input/ Output DP2# H16 Common Clk D47# G22 Source Sync Input/ Output Input/ Output DP3# J17 Common Clk D48# D20 Source Sync Input/ Output Input/ Output DRDY# C1 Common Clk D49# D17 Source Sync Input/ Output Input/ Output DSTBN0# C8 Source Sync D50# A14 Source Sync Input/ Output Input/ Output DSTBN1# G12 Source Sync D51# C15 Source Sync Input/ Output Input/ Output DSTBN2# G20 Source Sync D52# C14 Source Sync Input/ Output Input/ Output Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 59 Land Listing Table 4-1. Land Listing by Land Name (Sheet 7 of 23) Pin Name Pin No. Signal Buffer Type Direction Table 4-1. Land Listing by Land Name (Sheet 8 of 23) Pin Name Pin No. Signal Buffer Type Direction DSTBN3# A16 Source Sync Input/ Output REQ1# J5 Source Sync Input/ Output DSTBP0# B9 Source Sync Input/ Output REQ2# M6 Source Sync Input/ Output DSTBP1# E12 Source Sync Input/ Output REQ3# K6 Source Sync Input/ Output DSTBP2# G19 Source Sync Input/ Output REQ4# J6 Source Sync Input/ Output DSTBP3# C17 Source Sync Input/ Output RESERVED A20 FERR#/PBE# R3 Open Drain Asynchronous Output RESERVED A23 RESERVED A24 FORCEPR# AK6 CMOS Asynchronous Input RESERVED AC4 RESERVED AE3 RESERVED AE4 RESERVED AE6 RESERVED AH2 RESERVED AH7 RESERVED AJ3 RESERVED AJ7 RESERVED AK1 RESERVED AK3 GTLREF_ADD_END G10 Power/Other Input GTLREF_ADD_MID F2 Power/Other Input GTLREF_DATA_END H1 Power/Other Input GTLREF_DATA_MID H2 Power/Other Input HIT# D4 Common Clk Input/ Output HITM# E4 Common Clk Input/ Output IERR# AB2 Open Drain Asynchronous Output IGNNE# N2 CMOS Asynchronous Input INIT# P3 CMOS Asynchronous Input CMOS Asynchronous Input LINT0 K1 LINT1 L1 CMOS Asynchronous Input LL_ID0 V2 Power/Other Output LL_ID1 AA2 Power/Other Output LOCK# C3 Common Clk Input/ Output MCERR# AB3 Common Clk Input/ Output RESERVED AL1 RESERVED AM2 RESERVED AM6 RESERVED AN5 RESERVED AN6 RESERVED B13 RESERVED B23 RESERVED C23 RESERVED D1 RESERVED D14 RESERVED D16 RESERVED E1 MS_ID0 W1 Power/Other Output RESERVED E23 MS_ID1 V1 Power/Other Output RESERVED E24 PECI G5 Power/Other Input/ Output RESERVED E29 RESERVED E5 RESERVED E6 RESERVED E7 RESERVED F23 RESERVED F29 RESERVED F6 PROCHOT# AL2 Open Drain Asynchronous Output PWRGOOD N1 CMOS Asynchronous Input REQ0# K4 Source Sync Input/ Output 60 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Land Listing Table 4-1. Land Listing by Land Name (Sheet 9 of 23) Pin Name Pin No. Signal Buffer Type Table 4-1. Land Listing by Land Name (Sheet 10 of 23) Direction Pin Name Pin No. Signal Buffer Type RESERVED G6 VCC AC26 Power/Other RESERVED J2 VCC AC27 Power/Other RESERVED J3 VCC AC28 Power/Other RESERVED N5 VCC AC29 Power/Other RESERVED T2 VCC AC30 Power/Other RESERVED Y1 VCC AC8 Power/Other RESERVED Y3 VCC AD23 Power/Other RESET# G23 Common Clk Input VCC AD24 Power/Other RS0# B3 Common Clk Input VCC AD25 Power/Other RS1# F5 Common Clk Input VCC AD26 Power/Other RS2# A3 Common Clk Input VCC AD27 Power/Other RSP# H4 Common Clk Input VCC AD28 Power/Other SKTOCC# AE8 Power/Other Output VCC AD29 Power/Other SMI# P2 CMOS Asynchronous Input VCC AD30 Power/Other CMOS Asynchronous Input VCC AD8 Power/Other VCC AE11 Power/Other AE12 Power/Other STPCLK# M3 TCK AE1 TAP Input VCC TDI AD1 TAP Input VCC AE14 Power/Other AE15 Power/Other TDO AF1 TAP Output VCC TESTHI00 F26 Power/Other Input VCC AE18 Power/Other AE19 Power/Other TESTHI01 W3 Power/Other Input VCC TESTHI02 F25 Power/Other Input VCC AE21 Power/Other AE22 Power/Other TESTHI03 G25 Power/Other Input VCC TESTHI04 G27 Power/Other Input VCC AE23 Power/Other AE9 Power/Other TESTHI05 G26 Power/Other Input VCC TESTHI06 G24 Power/Other Input VCC AF11 Power/Other AF12 Power/Other TESTHI07 F24 Power/Other Input VCC TESTHI10 P1 Power/Other Input VCC AF14 Power/Other AF15 Power/Other TESTHI11 L2 Power/Other Input VCC TESTIN1 W2 Power/Other Input VCC AF18 Power/Other AF19 Power/Other TESTIN2 U1 Power/Other Input VCC THERMTRIP# M2 Open Drain Asynchronous Output VCC AF21 Power/Other VCC AF22 Power/Other VCC AF8 Power/Other VCC AF9 Power/Other VCC AG11 Power/Other VCC AG12 Power/Other VCC AG14 Power/Other VCC AG15 Power/Other VCC AG18 Power/Other TMS AC1 TAP Input TRDY# E3 Common Clk Input TRST# AG1 TAP Input VCC AA8 Power/Other VCC AB8 Power/Other VCC AC23 Power/Other VCC AC24 Power/Other VCC AC25 Power/Other Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Direction 61 Land Listing Table 4-1. Land Listing by Land Name (Sheet 11 of 23) Pin Name Pin No. Signal Buffer Type Table 4-1. Land Listing by Land Name (Sheet 12 of 23) Direction Pin Name Pin No. Signal Buffer Type VCC AG19 Power/Other VCC AK12 Power/Other VCC AG21 Power/Other VCC AK14 Power/Other VCC AG22 Power/Other VCC AK15 Power/Other VCC AG25 Power/Other VCC AK18 Power/Other VCC AG26 Power/Other VCC AK19 Power/Other VCC AG27 Power/Other VCC AK21 Power/Other VCC AG28 Power/Other VCC AK22 Power/Other VCC AG29 Power/Other VCC AK25 Power/Other VCC AG30 Power/Other VCC AK26 Power/Other VCC AG8 Power/Other VCC AK8 Power/Other VCC AG9 Power/Other VCC AK9 Power/Other VCC AH11 Power/Other VCC AL11 Power/Other VCC AH12 Power/Other VCC AL12 Power/Other VCC AH14 Power/Other VCC AL14 Power/Other VCC AH15 Power/Other VCC AL15 Power/Other VCC AH18 Power/Other VCC AL18 Power/Other VCC AH19 Power/Other VCC AL19 Power/Other VCC AH21 Power/Other VCC AL21 Power/Other VCC AH22 Power/Other VCC AL22 Power/Other VCC AH25 Power/Other VCC AL25 Power/Other VCC AH26 Power/Other VCC AL26 Power/Other VCC AH27 Power/Other VCC AL29 Power/Other VCC AH28 Power/Other VCC AL30 Power/Other VCC AH29 Power/Other VCC AL9 Power/Other VCC AH30 Power/Other VCC AM11 Power/Other VCC AH8 Power/Other VCC AM12 Power/Other VCC AH9 Power/Other VCC AM14 Power/Other VCC AJ11 Power/Other VCC AM15 Power/Other VCC AJ12 Power/Other VCC AM18 Power/Other VCC AJ14 Power/Other VCC AM19 Power/Other VCC AJ15 Power/Other VCC AM21 Power/Other VCC AJ18 Power/Other VCC AM22 Power/Other VCC AJ19 Power/Other VCC AM25 Power/Other VCC AJ21 Power/Other VCC AM26 Power/Other VCC AJ22 Power/Other VCC AM29 Power/Other VCC AJ25 Power/Other VCC AM30 Power/Other VCC AJ26 Power/Other VCC AM8 Power/Other VCC AJ8 Power/Other VCC AM9 Power/Other VCC AJ9 Power/Other VCC AN11 Power/Other VCC AK11 Power/Other VCC AN12 Power/Other 62 Direction Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Land Listing Table 4-1. Land Listing by Land Name (Sheet 13 of 23) Pin Name Pin No. Signal Buffer Type Table 4-1. Land Listing by Land Name (Sheet 14 of 23) Direction Pin Name Pin No. Signal Buffer Type VCC AN14 Power/Other VCC L8 Power/Other VCC AN15 Power/Other VCC M23 Power/Other VCC AN18 Power/Other VCC M24 Power/Other VCC AN19 Power/Other VCC M25 Power/Other VCC AN21 Power/Other VCC M26 Power/Other VCC AN22 Power/Other VCC M27 Power/Other VCC AN25 Power/Other VCC M28 Power/Other VCC AN26 Power/Other VCC M29 Power/Other VCC AN8 Power/Other VCC M30 Power/Other VCC AN9 Power/Other VCC M8 Power/Other VCC J10 Power/Other VCC N23 Power/Other VCC J11 Power/Other VCC N24 Power/Other VCC J12 Power/Other VCC N25 Power/Other VCC J13 Power/Other VCC N26 Power/Other VCC J14 Power/Other VCC N27 Power/Other VCC J15 Power/Other VCC N28 Power/Other VCC J18 Power/Other VCC N29 Power/Other VCC J19 Power/Other VCC N30 Power/Other VCC J20 Power/Other VCC N8 Power/Other VCC J21 Power/Other VCC P8 Power/Other VCC J22 Power/Other VCC R8 Power/Other VCC J23 Power/Other VCC T23 Power/Other VCC J24 Power/Other VCC T24 Power/Other VCC J25 Power/Other VCC T25 Power/Other VCC J26 Power/Other VCC T26 Power/Other VCC J27 Power/Other VCC T27 Power/Other VCC J28 Power/Other VCC T28 Power/Other VCC J29 Power/Other VCC T29 Power/Other VCC J30 Power/Other VCC T30 Power/Other VCC J8 Power/Other VCC T8 Power/Other VCC J9 Power/Other VCC U23 Power/Other VCC K23 Power/Other VCC U24 Power/Other VCC K24 Power/Other VCC U25 Power/Other VCC K25 Power/Other VCC U26 Power/Other VCC K26 Power/Other VCC U27 Power/Other VCC K27 Power/Other VCC U28 Power/Other VCC K28 Power/Other VCC U29 Power/Other VCC K29 Power/Other VCC U30 Power/Other VCC K30 Power/Other VCC U8 Power/Other VCC K8 Power/Other VCC V8 Power/Other Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Direction 63 Land Listing Table 4-1. Land Listing by Land Name (Sheet 15 of 23) Pin Name Pin No. Signal Buffer Type Table 4-1. Land Listing by Land Name (Sheet 16 of 23) Direction Pin Name Pin No. AA28 Signal Buffer Type VCC W23 Power/Other VSS VCC W24 Power/Other VSS AA29 Power/Other VCC W25 Power/Other VSS AA3 Power/Other VCC W26 Power/Other VSS AA30 Power/Other VCC W27 Power/Other VSS AA6 Power/Other VCC W28 Power/Other VSS AA7 Power/Other VCC W29 Power/Other VSS AB1 Power/Other Power/Other VCC W30 Power/Other VSS AB23 Power/Other VCC W8 Power/Other VSS AB24 Power/Other VCC Y23 Power/Other VSS AB25 Power/Other VCC Y24 Power/Other VSS AB26 Power/Other VCC Y25 Power/Other VSS AB27 Power/Other VCC Y26 Power/Other VSS AB28 Power/Other VCC Y27 Power/Other VSS AB29 Power/Other VCC Y28 Power/Other VSS AB30 Power/Other VCC Y29 Power/Other VSS AB7 Power/Other VCC Y30 Power/Other VSS AC3 Power/Other VCC Y8 Power/Other VSS AC6 Power/Other VCC_DIE_SENSE AN3 Power/Other Output VSS AC7 Power/Other VCC_DIE_SENSE2 AL8 Power/Other Output VSS AD4 Power/Other VCCPLL D23 Power/Other Input VSS AD7 Power/Other VID_SELECT AN7 Power/Other Output VSS AE10 Power/Other VID1 AL5 Power/Other Output VSS AE13 Power/Other VID2 AM3 Power/Other Output VSS AE16 Power/Other VID3 AL6 Power/Other Output VSS AE17 Power/Other VID4 AK4 Power/Other Output VSS AE2 Power/Other VID5 AL4 Power/Other Output VSS AE20 Power/Other VID6 AM5 Power/Other Output VSS AE24 Power/Other VSS A12 Power/Other VSS AE25 Power/Other VSS A15 Power/Other VSS AE26 Power/Other VSS A18 Power/Other VSS AE27 Power/Other VSS A2 Power/Other VSS AE28 Power/Other VSS A21 Power/Other VSS AE29 Power/Other VSS A6 Power/Other VSS AE30 Power/Other VSS A9 Power/Other VSS AE5 Power/Other VSS AA23 Power/Other VSS AE7 Power/Other VSS AA24 Power/Other VSS AF10 Power/Other VSS AA25 Power/Other VSS AF13 Power/Other VSS AA26 Power/Other VSS AF16 Power/Other VSS AA27 Power/Other VSS AF17 Power/Other 64 Direction Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Land Listing Table 4-1. Land Listing by Land Name (Sheet 17 of 23) Pin Name Pin No. Signal Buffer Type Table 4-1. Land Listing by Land Name (Sheet 18 of 23) Direction Pin Name Pin No. Signal Buffer Type VSS AF20 Power/Other VSS AJ30 VSS AF23 Power/Other VSS AJ4 Power/Other VSS AF24 Power/Other VSS AK10 Power/Other VSS AF25 Power/Other VSS AK13 Power/Other VSS AF26 Power/Other VSS AK16 Power/Other VSS AF27 Power/Other VSS AK17 Power/Other VSS AF28 Power/Other VSS AK2 Power/Other VSS AF29 Power/Other VSS AK20 Power/Other VSS AF3 Power/Other VSS AK23 Power/Other VSS AF30 Power/Other VSS AK24 Power/Other VSS AF6 Power/Other VSS AK27 Power/Other VSS AF7 Power/Other VSS AK28 Power/Other VSS AG10 Power/Other VSS AK29 Power/Other VSS AG13 Power/Other VSS AK30 Power/Other VSS AG16 Power/Other VSS AK5 Power/Other VSS AG17 Power/Other VSS AK7 Power/Other VSS AG20 Power/Other VSS AL10 Power/Other VSS AG23 Power/Other VSS AL13 Power/Other VSS AG24 Power/Other VSS AL16 Power/Other VSS AG7 Power/Other VSS AL17 Power/Other VSS AH1 Power/Other VSS AL20 Power/Other VSS AH10 Power/Other VSS AL23 Power/Other VSS AH13 Power/Other VSS AL24 Power/Other VSS AH16 Power/Other VSS AL27 Power/Other VSS AH17 Power/Other VSS AL28 Power/Other VSS AH20 Power/Other VSS AL3 Power/Other VSS AH23 Power/Other VSS AM1 Power/Other VSS AH24 Power/Other VSS AM10 Power/Other VSS AH3 Power/Other VSS AM13 Power/Other VSS AH6 Power/Other VSS AM16 Power/Other VSS AJ10 Power/Other VSS AM17 Power/Other VSS AJ13 Power/Other VSS AM20 Power/Other VSS AJ16 Power/Other VSS AM23 Power/Other VSS AJ17 Power/Other VSS AM24 Power/Other VSS AJ20 Power/Other VSS AM27 Power/Other VSS AJ23 Power/Other VSS AM28 Power/Other VSS AJ24 Power/Other VSS AM4 Power/Other VSS AJ27 Power/Other VSS AM7 Power/Other VSS AJ28 Power/Other VSS AN1 Power/Other VSS AJ29 Power/Other VSS AN10 Power/Other Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Direction Power/Other 65 Land Listing Table 4-1. Land Listing by Land Name (Sheet 19 of 23) Pin Name Pin No. Signal Buffer Type Table 4-1. Land Listing by Land Name (Sheet 20 of 23) Direction Pin Name Pin No. Signal Buffer Type VSS AN13 Power/Other VSS E28 Power/Other VSS AN16 Power/Other VSS E8 Power/Other VSS AN17 Power/Other VSS F1 Power/Other VSS AN2 Power/Other VSS F10 Power/Other VSS AN20 Power/Other VSS F13 Power/Other VSS AN23 Power/Other VSS F16 Power/Other VSS AN24 Power/Other VSS F19 Power/Other VSS B1 Power/Other VSS F22 Power/Other VSS B11 Power/Other VSS F4 Power/Other VSS B14 Power/Other VSS F7 Power/Other VSS B17 Power/Other VSS H10 Power/Other VSS B20 Power/Other VSS H11 Power/Other VSS B24 Power/Other VSS H12 Power/Other VSS B5 Power/Other VSS H13 Power/Other VSS B8 Power/Other VSS H14 Power/Other VSS C10 Power/Other VSS H17 Power/Other VSS C13 Power/Other VSS H18 Power/Other VSS C16 Power/Other VSS H19 Power/Other VSS C19 Power/Other VSS H20 Power/Other VSS C22 Power/Other VSS H21 Power/Other VSS C24 Power/Other VSS H22 Power/Other VSS C4 Power/Other VSS H23 Power/Other VSS C7 Power/Other VSS H24 Power/Other VSS D12 Power/Other VSS H25 Power/Other VSS D15 Power/Other VSS H26 Power/Other VSS D18 Power/Other VSS H27 Power/Other VSS D21 Power/Other VSS H28 Power/Other VSS D24 Power/Other VSS H29 Power/Other VSS D3 Power/Other VSS H3 Power/Other VSS D5 Power/Other VSS H6 Power/Other VSS D6 Power/Other VSS H7 Power/Other VSS D9 Power/Other VSS H8 Power/Other VSS E11 Power/Other VSS H9 Power/Other VSS E14 Power/Other VSS J4 Power/Other VSS E17 Power/Other VSS J7 Power/Other VSS E2 Power/Other VSS K2 Power/Other VSS E20 Power/Other VSS K5 Power/Other VSS E25 Power/Other VSS K7 Power/Other VSS E26 Power/Other VSS L23 Power/Other VSS E27 Power/Other VSS L24 Power/Other 66 Direction Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Land Listing Table 4-1. Land Listing by Land Name (Sheet 21 of 23) Pin Name Pin No. Signal Buffer Type Table 4-1. Land Listing by Land Name (Sheet 22 of 23) Direction Pin Name Pin No. Signal Buffer Type Direction VSS L25 Power/Other VSS V24 Power/Other VSS L26 Power/Other VSS V25 Power/Other VSS L27 Power/Other VSS V26 Power/Other VSS L28 Power/Other VSS V27 Power/Other VSS L29 Power/Other VSS V28 Power/Other VSS L3 Power/Other VSS V29 Power/Other VSS L30 Power/Other VSS V3 Power/Other VSS L6 Power/Other VSS V30 Power/Other VSS L7 Power/Other VSS V6 Power/Other VSS M1 Power/Other VSS V7 Power/Other VSS M7 Power/Other VSS W4 Power/Other VSS N3 Power/Other VSS W7 Power/Other VSS N6 Power/Other VSS Y2 Power/Other VSS N7 Power/Other VSS Y5 Power/Other VSS P23 Power/Other VSS Y7 Power/Other VSS P24 Power/Other VSS_DIE_SENSE AN4 Power/Other Output VSS P25 Power/Other VSS_DIE_SENSE2 AL7 Power/Other Output VSS P26 Power/Other VTT A25 Power/Other VSS P27 Power/Other VTT A26 Power/Other VSS P28 Power/Other VTT B25 Power/Other VSS P29 Power/Other VTT B26 Power/Other VSS P30 Power/Other VTT B27 Power/Other VSS P4 Power/Other VTT B28 Power/Other VSS P7 Power/Other VTT B29 Power/Other VSS R2 Power/Other VTT B30 Power/Other VSS R23 Power/Other VTT C25 Power/Other VSS R24 Power/Other VTT C26 Power/Other VSS R25 Power/Other VTT C27 Power/Other VSS R26 Power/Other VTT C28 Power/Other VSS R27 Power/Other VTT C29 Power/Other VSS R28 Power/Other VTT C30 Power/Other VSS R29 Power/Other VTT D25 Power/Other VSS R30 Power/Other VTT D26 Power/Other VSS R5 Power/Other VTT D27 Power/Other VSS R7 Power/Other VTT D28 Power/Other VSS T3 Power/Other VTT D29 Power/Other VSS T6 Power/Other VTT D30 Power/Other VSS T7 Power/Other VTT E30 Power/Other VSS U7 Power/Other VTT F30 Power/Other VSS V23 Power/Other VTT_OUT AA1 Power/Other Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Output 67 Land Listing Table 4-1. Land Listing by Land Name (Sheet 23 of 23) Pin Name Pin No. Signal Buffer Type Direction VTT_OUT J1 Power/Other Output VTT_SEL F27 Power/Other Output 68 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Land Listing 4.1.2 Land Listing by Land Number Table 4-2. Land Listing by Land Number (Sheet 1 of 20) Pin No. A10 Pin Name D08# Signal Buffer Type Source Sync Direction Table 4-2. Land Listing by Land Number (Sheet 2 of 20) Pin No. Pin Name Signal Buffer Type Input/Output AA7 VSS Power/Other Input/Output AA8 VCC Power/Other Direction A11 D09# Source Sync A12 VSS Power/Other AB1 VSS Power/Other AB2 IERR# Open Drain Asynchronous AB23 VSS Power/Other AB24 VSS Power/Other AB25 VSS Power/Other AB26 VSS Power/Other AB27 VSS Power/Other AB28 VSS Power/Other AB29 VSS Power/Other AB3 MCERR# Common Clk AB30 VSS Power/Other AB4 A26# Source Sync Input/Output AB5 A24# Source Sync Input/Output AB6 A17# Source Sync Input/Output AB7 VSS Power/Other AB8 VCC Power/Other AC1 TMS TAP Input AC2 DBR# Power/Other Output AC23 VCC Power/Other AC24 VCC Power/Other AC25 VCC Power/Other AC26 VCC Power/Other AC27 VCC Power/Other AC28 VCC Power/Other AC29 VCC Power/Other AC3 VSS Power/Other AC30 VCC Power/Other AC4 RESERVED AC5 A25# Source Sync AC6 VSS Power/Other A13 COMP0 Power/Other Input A14 D50# Source Sync Input/Output A15 VSS Power/Other A16 DSTBN3# Source Sync Input/Output A17 D56# Source Sync Input/Output A18 VSS Power/Other A19 D61# Source Sync A2 VSS Power/Other A20 RESERVED A21 VSS Power/Other A22 D62# Source Sync A23 RESERVED A24 RESERVED A25 VTT Power/Other A26 VTT Power/Other A3 RS2# Common Clk Input A4 D02# Source Sync Input/Output A5 D04# Source Sync Input/Output A6 VSS Power/Other A7 D07# Source Sync Input/Output A8 DBI0# Source Sync Input/Output A9 VSS Power/Other AA1 VTT_OUT Power/Other Output AA2 LL_ID1 Power/Other Output AA23 VSS Power/Other AA24 VSS Power/Other AA25 VSS Power/Other AA26 VSS Power/Other AA27 VSS Power/Other AA28 VSS Power/Other AA29 VSS Power/Other AA3 VSS Power/Other AA30 VSS Power/Other AA4 A21# Source Sync Input/Output AA5 A23# Source Sync Input/Output AA6 VSS Power/Other Input/Output Input/Output Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Output Input/Output Input/Output AC7 VSS Power/Other AC8 VCC Power/Other AD1 TDI TAP Input AD2 BPM2# Common Clk Output AD23 VCC Power/Other AD24 VCC Power/Other 69 Land Listing Table 4-2. Land Listing by Land Number (Sheet 3 of 20) Pin No. Pin Name Signal Buffer Type Direction Table 4-2. Land Listing by Land Number (Sheet 4 of 20) Pin No. Pin Name Signal Buffer Type AD25 VCC Power/Other AE8 SKTOCC# Power/Other AD26 VCC Power/Other AE9 VCC Power/Other AD27 VCC Power/Other AF1 TDO TAP AD28 VCC Power/Other AF10 VSS Power/Other AD29 VCC Power/Other AF11 VCC Power/Other AD3 BINIT# Common Clk AF12 VCC Power/Other AD30 VCC Power/Other AF13 VSS Power/Other Input/Output AD4 VSS Power/Other AF14 VCC Power/Other AD5 ADSTB1# Source Sync Input/Output AF15 VCC Power/Other AD6 A22# Source Sync Input/Output AF16 VSS Power/Other AD7 VSS Power/Other AF17 VSS Power/Other AF18 VCC Power/Other AF19 VCC Power/Other AD8 VCC Power/Other AE1 TCK TAP AE10 VSS Power/Other AF2 BPM4# Common Clk AE11 VCC Power/Other AF20 VSS Power/Other AE12 VCC Power/Other AF21 VCC Power/Other AE13 VSS Power/Other AF22 VCC Power/Other AE14 VCC Power/Other AF23 VSS Power/Other AE15 VCC Power/Other AF24 VSS Power/Other AE16 VSS Power/Other AF25 VSS Power/Other AE17 VSS Power/Other AF26 VSS Power/Other AE18 VCC Power/Other AF27 VSS Power/Other AE19 VCC Power/Other AF28 VSS Power/Other Input Direction Output Output Output AE2 VSS Power/Other AF29 VSS Power/Other AE20 VSS Power/Other AF3 VSS Power/Other AE21 VCC Power/Other AF30 VSS Power/Other AE22 VCC Power/Other AF4 A28# Source Sync Input/Output AE23 VCC Power/Other AF5 A27# Source Sync Input/Output AE24 VSS Power/Other AF6 VSS Power/Other AE25 VSS Power/Other AF7 VSS Power/Other AE26 VSS Power/Other AF8 VCC Power/Other AE27 VSS Power/Other AF9 VCC Power/Other AE28 VSS Power/Other AG1 TRST# TAP AE29 VSS Power/Other AG10 VSS Power/Other AE3 RESERVED AG11 VCC Power/Other AE30 VSS AG12 VCC Power/Other AE4 RESERVED AG13 VSS Power/Other AG14 VCC Power/Other AG15 VCC Power/Other AG16 VSS Power/Other AE5 VSS AE6 RESERVED AE7 VSS 70 Power/Other Power/Other Power/Other Input Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Land Listing Table 4-2. Land Listing by Land Number (Sheet 5 of 20) Pin No. Pin Name Signal Buffer Type Direction Table 4-2. Land Listing by Land Number (Sheet 6 of 20) Pin No. Pin Name Signal Buffer Type AG17 VSS Power/Other AH26 VCC Power/Other AG18 VCC Power/Other AH27 VCC Power/Other AG19 VCC Power/Other AH28 VCC Power/Other Input/Output Direction AG2 BPM3# Common Clk AH29 VCC Power/Other AG20 VSS Power/Other AH3 VSS Power/Other AG21 VCC Power/Other AH30 VCC Power/Other AG22 VCC Power/Other AH4 A32# Source Sync Input/Output AG23 VSS Power/Other AH5 A33# Source Sync Input/Output AG24 VSS Power/Other AH6 VSS Power/Other AG25 VCC Power/Other AH7 RESERVED AG26 VCC Power/Other AH8 VCC Power/Other AG27 VCC Power/Other AH9 VCC Power/Other AG28 VCC Power/Other AJ1 BPM1# Common Clk AG29 VCC Power/Other AJ10 VSS Power/Other AG3 BPM5# Common Clk AJ11 VCC Power/Other AG30 VCC Power/Other AJ12 VCC Power/Other AG4 A30# Source Sync Input/Output AJ13 VSS Power/Other AG5 A31# Source Sync Input/Output AJ14 VCC Power/Other AG6 A29# Source Sync Input/Output AJ15 VCC Power/Other AG7 VSS Power/Other AJ16 VSS Power/Other AG8 VCC Power/Other AJ17 VSS Power/Other AG9 VCC Power/Other AJ18 VCC Power/Other AH1 VSS Power/Other AJ19 VCC Power/Other AH10 VSS Power/Other AJ2 BPM0# Common Clk AH11 VCC Power/Other AJ20 VSS Power/Other AH12 VCC Power/Other AJ21 VCC Power/Other AH13 VSS Power/Other AJ22 VCC Power/Other AH14 VCC Power/Other AJ23 VSS Power/Other AH15 VCC Power/Other AJ24 VSS Power/Other AH16 VSS Power/Other AJ25 VCC Power/Other AH17 VSS Power/Other AJ26 VCC Power/Other AH18 VCC Power/Other AJ27 VSS Power/Other AH19 VCC Power/Other AJ28 VSS Power/Other Power/Other Input/Output Output Input/Output AH2 RESERVED AJ29 VSS AH20 VSS Power/Other AJ3 RESERVED AH21 VCC Power/Other AJ30 VSS Power/Other AH22 VCC Power/Other AJ4 VSS Power/Other AH23 VSS Power/Other AJ5 A34# Source Sync Input/Output AH24 VSS Power/Other AJ6 A35# Source Sync Input/Output AH25 VCC Power/Other AJ7 RESERVED Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 71 Land Listing Table 4-2. Land Listing by Land Number (Sheet 7 of 20) Pin No. AJ8 Pin Name Signal Buffer Type Direction Table 4-2. Land Listing by Land Number (Sheet 8 of 20) Pin No. Pin Name Signal Buffer Type VCC Power/Other AL17 VSS Power/Other AJ9 VCC Power/Other AL18 VCC Power/Other AK1 RESERVED AL19 VCC Power/Other AK10 VSS Power/Other AL2 PROCHOT# AK11 VCC Power/Other Open Drain Asynchronous AK12 VCC Power/Other AL20 VSS Power/Other AK13 VSS Power/Other AL21 VCC Power/Other AK14 VCC Power/Other AL22 VCC Power/Other AK15 VCC Power/Other AL23 VSS Power/Other AK16 VSS Power/Other AL24 VSS Power/Other AK17 VSS Power/Other AL25 VCC Power/Other AK18 VCC Power/Other AL26 VCC Power/Other AK19 VCC Power/Other AL27 VSS Power/Other AK2 VSS Power/Other AL28 VSS Power/Other AK20 VSS Power/Other AK21 VCC Power/Other AK22 VCC Power/Other AK23 VSS Power/Other AK24 VSS Power/Other AK25 VCC Power/Other AK26 VCC Power/Other AK27 VSS Power/Other AK28 VSS Power/Other AK29 VSS Power/Other AK3 RESERVED AK30 VSS Power/Other AK4 VID4 Power/Other AK5 VSS Power/Other AK6 FORCEPR# CMOS Asynchronous AK7 VSS AK8 VCC AK9 VCC Power/Other AL1 RESERVED AL10 VSS AL11 VCC AL12 VCC AL13 VSS AL14 AL15 AL16 72 VCC Power/Other AL3 VSS Power/Other AL30 VCC Power/Other AL4 VID5 Power/Other Output AL5 VID1 Power/Other Output AL6 VID3 Power/Other Output VSS_DIE_SENSE2 Power/Other AL8 VCC_DIE_SENSE2 Power/Other AL9 VCC Power/Other AM1 VSS Power/Other AM10 VSS Power/Other AM11 VCC Power/Other AM12 VCC Power/Other AM13 VSS Power/Other AM14 VCC Power/Other AM15 VCC Power/Other Power/Other AM16 VSS Power/Other Power/Other AM17 VSS Power/Other AM18 VCC Power/Other AM19 VCC Power/Other Power/Other AM2 RESERVED Power/Other AM20 VSS Power/Other Power/Other AM21 VCC Power/Other Power/Other AM22 VCC Power/Other VCC Power/Other AM23 VSS Power/Other VCC Power/Other AM24 VSS Power/Other VSS Power/Other AM25 VCC Power/Other Input Output AL29 AL7 Output Direction Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Land Listing Table 4-2. Land Listing by Land Number (Sheet 9 of 20) Pin No. Pin Name Signal Buffer Type Direction Table 4-2. Land Listing by Land Number (Sheet 10 of 20) Pin No. Pin Name Signal Buffer Type Direction AM26 VCC Power/Other B11 VSS Power/Other AM27 VSS Power/Other B12 D13# Source Sync AM28 VSS Power/Other B13 RESERVED AM29 VCC Power/Other B14 VSS Power/Other AM3 VID2 Power/Other B15 D53# Source Sync Input/Output AM30 VCC Power/Other B16 D55# Source Sync Input/Output AM4 VSS Power/Other B17 VSS Power/Other AM5 VID6 Power/Other B18 D57# Source Sync Input/Output AM6 RESERVED B19 D60# Source Sync Input/Output AM7 VSS Power/Other B2 DBSY# Common Clk Input/Output AM8 VCC Power/Other B20 VSS Power/Other Output Output Input/Output AM9 VCC Power/Other B21 D59# Source Sync Input/Output AN1 VSS Power/Other B22 D63# Source Sync Input/Output AN10 VSS Power/Other B23 RESERVED AN11 VCC Power/Other B24 VSS Power/Other AN12 VCC Power/Other B25 VTT Power/Other AN13 VSS Power/Other B26 VTT Power/Other AN14 VCC Power/Other B27 VTT Power/Other AN15 VCC Power/Other B28 VTT Power/Other AN16 VSS Power/Other B29 VTT Power/Other AN17 VSS Power/Other B3 RS0# Common Clk AN18 VCC Power/Other B30 VTT Power/Other AN19 VCC Power/Other B4 D00# Source Sync Input Input/Output AN2 VSS Power/Other B5 VSS Power/Other AN20 VSS Power/Other B6 D05# Source Sync Input/Output AN21 VCC Power/Other B7 D06# Source Sync Input/Output AN22 VCC Power/Other B8 VSS Power/Other AN23 VSS Power/Other B9 DSTBP0# Source Sync Input/Output AN24 VSS Power/Other C1 DRDY# Common Clk Input/Output AN25 VCC Power/Other C10 VSS Power/Other AN26 VCC Power/Other C11 D11# Source Sync Input/Output AN3 VCC_DIE_SENSE Power/Other Output C12 D14# Source Sync Input/Output AN4 VSS_DIE_SENSE Power/Other Output C13 VSS Power/Other AN5 RESERVED C14 D52# Source Sync Input/Output AN6 RESERVED C15 D51# Source Sync Input/Output AN7 VID_SELECT Power/Other C16 VSS Power/Other AN8 VCC Power/Other C17 DSTBP3# Source Sync Input/Output Input/Output Output AN9 VCC Power/Other C18 D54# Source Sync B1 VSS Power/Other C19 VSS Power/Other B10 D10# Source Sync C2 BNR# Common Clk Input/Output Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Input/Output 73 Land Listing Table 4-2. Land Listing by Land Number (Sheet 11 of 20) Pin No. Pin Name Signal Buffer Type C20 DBI3# C21 C22 C23 RESERVED C24 VSS Power/Other C25 VTT C26 VTT C27 C28 Direction Table 4-2. Land Listing by Land Number (Sheet 12 of 20) Pin No. Pin Name Direction Source Sync Input/Output D3 D58# Source Sync Input/Output D30 VTT Power/Other VSS Power/Other D4 HIT# Common Clk D5 VSS Power/Other D6 VSS Power/Other Power/Other D7 D20# Source Sync Input/Output Power/Other D8 D12# Source Sync Input/Output VTT Power/Other D9 VSS Power/Other VTT Power/Other E1 RESERVED Power/Other C29 VTT Power/Other E10 D21# Source Sync C3 LOCK# Common Clk E11 VSS Power/Other C30 VTT Power/Other E12 DSTBP1# Source Sync Input/Output C4 VSS Power/Other E13 D26# Source Sync Input/Output C5 D01# Source Sync Input/Output E14 VSS Power/Other C6 D03# Source Sync Input/Output E15 D33# Source Sync Input/Output C7 VSS Power/Other E16 D34# Source Sync Input/Output C8 DSTBN0# Source Sync Input/Output E17 VSS Power/Other C9 BPMb1# Common Clk Output E18 D39# Source Sync Input/Output D1 RESERVED E19 D40# Source Sync Input/Output D10 D22# Source Sync Input/Output E2 VSS Power/Other D11 D15# Source Sync Input/Output E20 VSS Power/Other D12 VSS Power/Other E21 D42# Source Sync Input/Output D13 D25# Source Sync E22 D45# Source Sync Input/Output E23 RESERVED E24 RESERVED E25 VSS Power/Other E26 VSS Power/Other Input/Output Input/Output VSS Signal Buffer Type Power/Other D14 RESERVED D15 VSS D16 RESERVED D17 D49# Source Sync D18 VSS Power/Other E27 VSS Power/Other D19 DBI2# Source Sync Input/Output E28 VSS Power/Other D2 ADS# Common Clk Input/Output E29 RESERVED D20 D48# Source Sync Input/Output E3 TRDY# D21 VSS Power/Other E30 VTT Power/Other D22 D46# Source Sync Input/Output E4 HITM# Common Clk D23 VCCPLL Power/Other Input E5 RESERVED D24 VSS Power/Other E6 RESERVED D25 VTT Power/Other E7 RESERVED D26 VTT Power/Other E8 VSS Power/Other D27 VTT Power/Other E9 D19# Source Sync D28 VTT Power/Other F1 VSS Power/Other D29 VTT Power/Other F10 VSS Power/Other 74 Power/Other Input/Output Common Clk Input/Output Input/Output Input Input/Output Input/Output Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Land Listing Table 4-2. Land Listing by Land Number (Sheet 13 of 20) Pin No. F11 Pin Name D23# Signal Buffer Type Direction Table 4-2. Land Listing by Land Number (Sheet 14 of 20) Pin No. Pin Name Signal Buffer Type Direction Source Sync Input/Output G20 DSTBN2# Source Sync Input/Output Input/Output G21 D44# Source Sync Input/Output G22 D47# Source Sync Input/Output F12 D24# Source Sync F13 VSS Power/Other F14 D28# Source Sync Input/Output G23 RESET# Common Clk Input F15 D30# Source Sync Input/Output G24 TESTHI06 Power/Other Input F16 VSS Power/Other G25 TESTHI03 Power/Other Input F17 D37# Source Sync Input/Output G26 TESTHI05 Power/Other Input Input/Output G27 TESTHI04 Power/Other Input G28 BCLK1 Clk Input G29 BSEL0 CMOS Asynchronous Output G3 BPMb3# Common Clk Input/Output G30 BSEL2 CMOS Asynchronous Output F18 D38# Source Sync F19 VSS Power/Other F2 GTLREF_ADD_MID Power/Other Input F20 D41# Source Sync Input/Output F21 D43# Source Sync Input/Output F22 VSS Power/Other F23 RESERVED G4 BPMb2# Common Clk Output F24 TESTHI07 Power/Other Input G5 PECI Power/Other Input/Output F25 TESTHI02 Power/Other Input G6 RESERVED F26 TESTHI00 Power/Other Input G7 DEFER# Common Clk Input F27 VTT_SEL Power/Other Output G8 BPRI# Common Clk Input F28 BCLK0 Clk Input G9 D16# Source Sync Input/Output F29 RESERVED H1 GTLREF_DATA_END Power/Other Input F3 BR0# Common Clk H10 VSS Power/Other F30 VTT Power/Other H11 VSS Power/Other F4 VSS Power/Other H12 VSS Power/Other F5 RS1# Common Clk H13 VSS Power/Other F6 RESERVED H14 VSS Power/Other F7 VSS Power/Other H15 DP1# Common Clk Input/Output F8 D17# Source Sync Input/Output H16 DP2# Common Clk Input/Output F9 D18# Source Sync Input/Output H17 VSS Power/Other G1 BPMb0# Power/Other Input/Output H18 VSS Power/Other G10 GTLREF_ADD_END Power/Other Input H19 VSS Power/Other G11 DBI1# Source Sync Input/Output H2 GTLREF_DATA_MID Power/Other G12 DSTBN1# Source Sync Input/Output H20 VSS Power/Other G13 D27# Source Sync Input/Output H21 VSS Power/Other G14 D29# Source Sync Input/Output H22 VSS Power/Other G15 D31# Source Sync Input/Output H23 VSS Power/Other G16 D32# Source Sync Input/Output H24 VSS Power/Other G17 D36# Source Sync Input/Output H25 VSS Power/Other G18 D35# Source Sync Input/Output H26 VSS Power/Other G19 DSTBP2# Source Sync Input/Output H27 VSS Power/Other G2 COMP2 Power/Other Input H28 VSS Power/Other Input/Output Input Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Input 75 Land Listing Table 4-2. Land Listing by Land Number (Sheet 15 of 20) Pin No. Pin Name Signal Buffer Type Direction H29 VSS Power/Other H3 VSS Power/Other H30 BSEL1 CMOS Asynchronous Output H4 RSP# Common Clk H5 BR1# Common Clk H6 VSS H7 VSS H8 H9 Table 4-2. Land Listing by Land Number (Sheet 16 of 20) Pin No. K1 Pin Name LINT0 Signal Buffer Type CMOS Asynchronous Direction Input K2 VSS Power/Other K23 VCC Power/Other Input K24 VCC Power/Other Input K25 VCC Power/Other Power/Other K26 VCC Power/Other Power/Other K27 VCC Power/Other VSS Power/Other K28 VCC Power/Other VSS Power/Other K29 VCC Power/Other J1 VTT_OUT Power/Other K3 A20M# J10 VCC Power/Other CMOS Asynchronous J11 VCC Power/Other K30 VCC Power/Other J12 VCC Power/Other K4 REQ0# Source Sync J13 VCC Power/Other K5 VSS Power/Other J14 VCC Power/Other K6 REQ3# Source Sync J15 VCC Power/Other K7 VSS Power/Other J16 DP0# Common Clk Input/Output K8 VCC Power/Other J17 DP3# Common Clk Input/Output L1 LINT1 CMOS Asynchronous Input J18 VCC Power/Other L2 TESTHI11 Power/Other Input J19 VCC Power/Other L23 VSS Power/Other J2 RESERVED L24 VSS Power/Other J20 VCC Power/Other L25 VSS Power/Other J21 VCC Power/Other L26 VSS Power/Other J22 VCC Power/Other L27 VSS Power/Other J23 VCC Power/Other L28 VSS Power/Other J24 VCC Power/Other L29 VSS Power/Other J25 VCC Power/Other L3 VSS Power/Other J26 VCC Power/Other L30 VSS Power/Other J27 VCC Power/Other L4 A06# Source Sync Input/Output J28 VCC Power/Other L5 A05# Source Sync Input/Output J29 VCC Power/Other L6 VSS Power/Other J3 RESERVED L7 VSS Power/Other J30 VCC Power/Other L8 VCC Power/Other J4 VSS Power/Other M1 VSS Power/Other J5 REQ1# Source Sync Input/Output M2 THERMTRIP# J6 REQ4# Source Sync Input/Output Open Drain Asynchronous J7 VSS Power/Other M23 VCC Power/Other J8 VCC Power/Other M24 VCC Power/Other M25 VCC Power/Other M26 VCC Power/Other J9 76 VCC Power/Other Output Input Input/Output Input/Output Output Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Land Listing Table 4-2. Land Listing by Land Number (Sheet 17 of 20) Pin No. Pin Name Signal Buffer Type Direction Table 4-2. Land Listing by Land Number (Sheet 18 of 20) Pin No. Pin Name Signal Buffer Type Direction M27 VCC Power/Other P5 A37# Source Sync Input/Output M28 VCC Power/Other P6 A04# Source Sync Input/Output M29 VCC Power/Other P7 VSS Power/Other M3 STPCLK# CMOS Asynchronous Input M30 VCC Power/Other M4 A07# Source Sync Input/Output M5 A03# Source Sync Input/Output M6 REQ2# Source Sync Input/Output M7 VSS Power/Other M8 VCC Power/Other N1 PWRGOOD CMOS Asynchronous Input Input P8 VCC Power/Other R1 COMP3 Power/Other R2 VSS Power/Other R23 VSS Power/Other R24 VSS Power/Other R25 VSS Power/Other R26 VSS Power/Other R27 VSS Power/Other R28 VSS Power/Other R29 VSS Power/Other R3 FERR#/PBE# Open Drain Asynchronous VSS Power/Other N2 IGNNE# CMOS Asynchronous N23 VCC Power/Other N24 VCC Power/Other R30 N25 VCC Power/Other R4 A08# Source Sync VSS Power/Other N26 VCC Power/Other R5 N27 VCC Power/Other R6 ADSTB0# Source Sync VSS Power/Other N28 VCC Power/Other R7 N29 VCC Power/Other R8 VCC Power/Other COMP1 Power/Other N3 VSS Power/Other T1 N30 VCC Power/Other T2 RESERVED Source Sync T23 VCC Power/Other Output Input/Output Input/Output Input N4 A36# N5 RESERVED T24 VCC Power/Other N6 VSS Power/Other T25 VCC Power/Other N7 VSS Power/Other T26 VCC Power/Other T27 VCC Power/Other Input T28 VCC Power/Other Input T29 VCC Power/Other T3 VSS Power/Other T30 VCC Power/Other T4 A11# Source Sync Input/Output T5 A09# Source Sync Input/Output T6 VSS Power/Other T7 VSS Power/Other T8 VCC Power/Other U1 TESTIN2 Power/Other Input Input/Output N8 VCC Power/Other P1 TESTHI10 Power/Other P2 SMI# CMOS Asynchronous P23 VSS Power/Other P24 VSS Power/Other P25 VSS Power/Other P26 VSS Power/Other P27 VSS Power/Other P28 VSS Power/Other P29 VSS Power/Other P3 INIT# CMOS Asynchronous P30 VSS Power/Other P4 VSS Power/Other Input/Output Input Input Quad-Core Intel® Xeon® Processor 5300 Series Datasheet U2 AP0# Common Clk U23 VCC Power/Other U24 VCC Power/Other 77 Land Listing Table 4-2. Land Listing by Land Number (Sheet 19 of 20) Pin No. Pin Name Signal Buffer Type Table 4-2. Land Listing by Land Number (Sheet 20 of 20) Pin No. Direction Pin Name Signal Buffer Type Direction U25 VCC Power/Other W27 VCC Power/Other U26 VCC Power/Other W28 VCC Power/Other U27 VCC Power/Other W29 VCC Power/Other U28 VCC Power/Other W3 TESTHI01 Power/Other U29 VCC Power/Other W30 VCC Power/Other U3 AP1# Common Clk W4 VSS Power/Other U30 VCC Power/Other W5 A16# Source Sync Input/Output U4 A13# Source Sync Input/Output W6 A18# Source Sync Input/Output U5 A12# Source Sync Input/Output W7 VSS Power/Other Input/Output W8 VCC Power/Other Y1 RESERVED Input/Output U6 A10# Source Sync U7 VSS Power/Other U8 VCC Power/Other Y2 VSS Power/Other V1 MS_ID1 Power/Other Output Y23 VCC Power/Other V2 LL_ID0 Power/Other Output Y24 VCC Power/Other V23 VSS Power/Other Y25 VCC Power/Other V24 VSS Power/Other Y26 VCC Power/Other V25 VSS Power/Other Y27 VCC Power/Other V26 VSS Power/Other Y28 VCC Power/Other V27 VSS Power/Other Y29 VCC Power/Other V28 VSS Power/Other Y3 RESERVED V29 VSS Power/Other Y30 VCC Power/Other V3 VSS Power/Other Y4 A20# Source Sync V30 VSS Power/Other Y5 VSS Power/Other V4 A15# Source Sync Input/Output Y6 A19# Source Sync V5 A14# Source Sync Input/Output Y7 VSS Power/Other V6 VSS Power/Other Y8 VCC Power/Other V7 VSS Power/Other V8 VCC Power/Other W1 MS_ID0 Power/Other Output W2 TESTIN1 Power/Other Input W23 VCC Power/Other W24 VCC Power/Other W25 VCC Power/Other W26 VCC Power/Other Input Input/Output Input/Output § 78 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Signal Definitions 5 Signal Definitions 5.1 Signal Definitions Table 5-1. Signal Definitions (Sheet 1 of 7) Name Description Notes I/O A[37:3]# (Address) define a 2 -byte physical memory address space. In sub-phase 1 of the address phase, these signals transmit the address of a transaction. In subphase 2, these signals transmit transaction type information. These signals must connect the appropriate pins of all agents on the FSB. A[37:3]#4 are protected by parity signals AP[1:0]#. A[37:3]#4 are source synchronous signals and are latched into the receiving buffers by ADSTB[1:0]#. On the active-to-inactive transition of RESET#, the processors sample a subset of the A[37:3]#4 lands to determine their power-on configuration. See Section 7.1. 3,4 I If A20M# (Address-20 Mask) is asserted, the processor masks physical address bit 20 (A20#) before looking up a line in any internal cache and before driving a read/write transaction on the bus. Asserting A20M# emulates the 8086 processor's address wrap-around at the 1 MB boundary. Assertion of A20M# is only supported in real mode. A20M# is an asynchronous signal. However, to ensure recognition of this signal following an I/O write instruction, it must be valid along with the TRDY# assertion of the corresponding I/O write bus transaction. 2 ADS# I/O ADS# (Address Strobe) is asserted to indicate the validity of the transaction address on the A[37:3]#4 lands. All bus agents observe the ADS# activation to begin parity checking, protocol checking, address decode, internal snoop, or deferred reply ID match operations associated with the new transaction. This signal must be connected to the appropriate pins on all Quad-Core Intel® Xeon® Processor 5300 Series FSB agents. 3 ADSTB[1:0]# I/O Address strobes are used to latch A[37:3]#4 and REQ[4:0]# on their rising and falling edge. Strobes are associated with signals as shown below. 3,4 A[37:3]# A20M# AP[1:0]# Type I/O 38 Signals Associated Strobes REQ[4:0], A[16:3]#, A[37:36]#4 ADSTB0# A[35:17]# ADSTB1# AP[1:0]# (Address Parity) are driven by the request initiator along with ADS#, A[37:3]#4, and the transaction type on the REQ[4:0]# signals. A correct parity signal is high if an even number of covered signals are low and low if an odd number of covered signals are low. This allows parity to be high when all the covered signals are high. AP[1:0]# must be connected to the appropriate pins of all Quad-Core Intel® Xeon® Processor 5300 Series FSB agents. The following table defines the coverage model of these signals. Request Signals Subphase 1 Subphase 2 4 AP0# AP1# A[23:3]# AP1# AP0# REQ[4:0]# AP1# AP0# A[37:24]# BCLK[1:0] I The differential bus clock pair BCLK[1:0] (Bus Clock) determines the FSB frequency. All processor FSB agents must receive these signals to drive their outputs and latch their inputs. All external timing parameters are specified with respect to the rising edge of BCLK0 crossing VCROSS. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 3,4 3 79 Signal Definitions Table 5-1. Name Signal Definitions (Sheet 2 of 7) Type Description Notes BINIT# I/O BINIT# (Bus Initialization) may be observed and driven by all processor FSB agents and if used, must connect the appropriate pins of all such agents. If the BINIT# driver is enabled during power on configuration, BINIT# is asserted to signal any bus condition that prevents reliable future operation. If BINIT# observation is enabled during power-on configuration (see Section 7.1) and BINIT# is sampled asserted, symmetric agents reset their bus LOCK# activity and bus request arbitration state machines. The bus agents do not reset their I/O Queue (IOQ) and transaction tracking state machines upon observation of BINIT# assertion. Once the BINIT# assertion has been observed, the bus agents will re-arbitrate for the FSB and attempt completion of their bus queue and IOQ entries. If BINIT# observation is disabled during power-on configuration, a priority agent may handle an assertion of BINIT# as appropriate to the error handling architecture of the system. 3 BNR# I/O BNR# (Block Next Request) is used to assert a bus stall by any bus agent who is unable to accept new bus transactions. During a bus stall, the current bus owner cannot issue any new transactions. Since multiple agents might need to request a bus stall at the same time, BNR# is a wired-OR signal which must connect the appropriate pins of all processor FSB agents. In order to avoid wired-OR glitches associated with simultaneous edge transitions driven by multiple drivers, BNR# is activated on specific clock edges and sampled on specific clock edges. 3 BPM5# BPM4# BPM3# BPM[2:1]# BPM0# I/O BPM[5:0]# (Breakpoint Monitor) are breakpoint and performance monitor signals. They are outputs from the processor which indicate the status of breakpoints and programmable counters used for monitoring processor performance. BPM[5:0]# should connect the appropriate pins of all FSB agents. BPM4# provides PRDY# (Probe Ready) functionality for the TAP port. PRDY# is a processor output used by debug tools to determine processor debug readiness. BPM5# provides PREQ# (Probe Request) functionality for the TAP port. PREQ# is used by debug tools to request debug operation of the processors. BPM[5:4]# must be bussed to all bus agents. Please refer to the appropriate platform design guidelines for more detailed information. 2 BPMb3# BPMb[2:1]# BPMb0# I/O O I/O BPMb[3:0]# (Breakpoint Monitor) are a second set of breakpoint and performance monitor signals. They are additional outputs from the processor which indicate the status of breakpoints and programmable counters used for monitoring processor performance. BPMb[3:0]# should connect the appropriate pins of all FSB agents. 2 I BPRI# (Bus Priority Request) is used to arbitrate for ownership of the processor FSB. It must connect the appropriate pins of all processor FSB agents. Observing BPRI# active (as asserted by the priority agent) causes all other agents to stop issuing new requests, unless such requests are part of an ongoing locked operation. The priority agent keeps BPRI# asserted until all of its requests are completed, then releases the bus by deasserting BPRI#. 3 BR[1:0]# I/O The BR[1:0]# signals are sampled on the active-to-inactive transition of RESET#. The signal which the agent samples asserted determines its agent ID. BR0# drives the BREQ0# signal in the system and is used by the processor to request the bus. These signals do not have on-die termination and must be terminated. 3 BSEL[2:0] O The BCLK[1:0] frequency select signals BSEL[2:0] are used to select the processor input clock frequency. Table 2-2 defines the possible combinations of the signals and the frequency associated with each combination. The required frequency is determined by the processors, chipset, and clock synthesizer. All FSB agents must operate at the same frequency. For more information about these signals, including termination recommendations, refer to the appropriate platform design guideline. COMP[3:0] I COMP[3:0] must be terminated to VSS on the baseboard using precision resistors. These inputs configure the AGTL+ drivers of the processor. Refer to the appropriate platform design guidelines for implementation details. BPRI# 80 O I/O O I/O Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Signal Definitions Table 5-1. Name D[63:0]# Signal Definitions (Sheet 3 of 7) Type Description Notes I/O D[63:0]# (Data) are the data signals. These signals provide a 64-bit data path between the processor FSB agents, and must connect the appropriate pins on all such agents. The data driver asserts DRDY# to indicate a valid data transfer. 3 D[63:0]# are quad-pumped signals, and will thus be driven four times in a common clock period. D[63:0]# are latched off the falling edge of both DSTBP[3:0]# and DSTBN[3:0]#. Each group of 16 data signals correspond to a pair of one DSTBP# and one DSTBN#. The following table shows the grouping of data signals to strobes and DBI#. Data Group DSTBN#/ DSTBP# DBI# D[15:0]# 0 0 D[31:16]# 1 1 D[47:32]# 2 2 D[63:48]# 3 3 Furthermore, the DBI# signals determine the polarity of the data signals. Each group of 16 data signals corresponds to one DBI# signal. When the DBI# signal is active, the corresponding data group is inverted and therefore sampled active high. DBI[3:0]# I/O DBI[3:0]# (Data Bus Inversion) are source synchronous and indicate the polarity of the D[63:0]# signals. The DBI[3:0]# signals are activated when the data on the data bus is inverted. If more than half the data bits, within, within a 16-bit group, would have been asserted electronically low, the bus agent may invert the data bus signals for that particular sub-phase for that 16-bit group. 3 DBI[3:0] Assignment to Data Bus Bus Signal DBR# Data Bus Signals DBI0# D[15:0]# DBI1# D[31:16]# DBI2# D[47:32]# DBI3# D[63:48]# O DBR# is used only in systems where no debug port connector is implemented on the system board. DBR# is used by a debug port interposer so that an in-target probe can drive reset. If a debug port connector is implemented in the system, DBR# is a noconnect on the Quad-Core Intel® Xeon® Processor 5300 Series package. DBR# is not a processor signal. DBSY# I/O DBSY# (Data Bus Busy) is asserted by the agent responsible for driving data on the processor FSB to indicate that the data bus is in use. The data bus is released after DBSY# is deasserted. This signal must connect the appropriate pins on all processor FSB agents. 3 DEFER# I DEFER# is asserted by an agent to indicate that a transaction cannot be guaranteed in-order completion. Assertion of DEFER# is normally the responsibility of the addressed memory or I/O agent. This signal must connect the appropriate pins of all processor FSB agents. 3 DP[3:0]# I/O DP[3:0]# (Data Parity) provide parity protection for the D[63:0]# signals. They are driven by the agent responsible for driving D[63:0]#, and must connect the appropriate pins of all processor FSB agents. 3 DRDY# I/O DRDY# (Data Ready) is asserted by the data driver on each data transfer, indicating valid data on the data bus. In a multi-common clock data transfer, DRDY# may be deasserted to insert idle clocks. This signal must connect the appropriate pins of all processor FSB agents. 3 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 81 Signal Definitions Table 5-1. Signal Definitions (Sheet 4 of 7) Name DSTBN[3:0]# DSTBP[3:0]# Type I/O I/O Description Data strobe used to latch in D[63:0]#. Signals Associated Strobes D[15:0]#, DBI0# DSTBN0# D[31:16]#, DBI1# DSTBN1# D[47:32]#, DBI2# DSTBN2# D[63:48]#, DBI3# DSTBN3# Data strobe used to latch in D[63:0]#. Signals Associated Strobes D[15:0]#, DBI0# DSTBP0# D[31:16]#, DBI1# DSTBP1# D[47:32]#, DBI2# DSTBP2# D[63:48]#, DBI3# DSTBP3# Notes 3 3 FERR#/PBE# O FERR#/PBE# (floating-point error/pending break event) is a multiplexed signal and its meaning is qualified by STPCLK#. When STPCLK# is not asserted, FERR#/PBE# indicates a floating-point error and will be asserted when the processor detects an unmasked floating-point error. When STPCLK# is not asserted, FERR#/PBE# is similar to the ERROR# signal on the Intel 387 coprocessor, and is included for compatibility with systems using MS-DOS*-type floating-point error reporting. When STPCLK# is asserted, an assertion of FERR#/PBE# indicates that the processor has a pending break event waiting for service. The assertion of FERR#/PBE# indicates that the processor should be returned to the Normal state. For additional information on the pending break event functionality, including the identification of support of the feature and enable/disable information, refer to Vol. 3 of the Intel® 64 and IA-32 Intel® Architecture Software Developer’s Manual and the AP-485 Intel® Processor Identification and the CPUID Instruction application note. FORCEPR# I The FORCEPR# (force power reduction) input can be used by the platform to cause the Quad-Core Intel® Xeon® Processor 5300 Series to activate the Thermal Control Circuit (TCC). GTLREF_ADD_MID GTLREF_ADD_END I GTLREF_ADD determines the signal reference level for AGTL+ address and common clock input lands. GTLREF_ADD is used by the AGTL+ receivers to determine if a signal is a logical 0 or a logical 1. Please refer to Table 2-20 and the appropriate platform design guidelines for additional details. GTLREF_DATA_MID GTLREF_DATA_END I GTLREF_DATA determines the signal reference level for AGTL+ data input lands. GTLREF_DATA is used by the AGTL+ receivers to determine if a signal is a logical 0 or a logical 1. Please refer to Table 2-20 and the appropriate platform design guidelines for additional details. HIT# HITM# I/O I/O HIT# (Snoop Hit) and HITM# (Hit Modified) convey transaction snoop operation results. Any FSB agent may assert both HIT# and HITM# together to indicate that it requires a snoop stall, which can be continued by reasserting HIT# and HITM# together. 3 IERR# O IERR# (Internal Error) is asserted by a processor as the result of an internal error. Assertion of IERR# is usually accompanied by a SHUTDOWN transaction on the processor FSB. This transaction may optionally be converted to an external error signal (e.g., NMI) by system core logic. The processor will keep IERR# asserted until the assertion of RESET#. This signal does not have on-die termination. 2 82 2 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Signal Definitions Table 5-1. Name Signal Definitions (Sheet 5 of 7) Type Description Notes IGNNE# I IGNNE# (Ignore Numeric Error) is asserted to force the processor to ignore a numeric error and continue to execute noncontrol floating-point instructions. If IGNNE# is deasserted, the processor generates an exception on a noncontrol floating-point instruction if a previous floating-point instruction caused an error. IGNNE# has no effect when the NE bit in control register 0 (CR0) is set. IGNNE# is an asynchronous signal. However, to ensure recognition of this signal following an I/O write instruction, it must be valid along with the TRDY# assertion of the corresponding I/O write bus transaction. 2 INIT# I INIT# (Initialization), when asserted, resets integer registers inside all processors without affecting their internal caches or floating-point registers. Each processor then begins execution at the power-on Reset vector configured during power-on configuration. The processor continues to handle snoop requests during INIT# assertion. INIT# is an asynchronous signal and must connect the appropriate pins of all processor FSB agents. 2 LINT[1:0] I LINT[1:0] (Local APIC Interrupt) must connect the appropriate pins of all FSB agents. When the APIC functionality is disabled, the LINT0/INTR signal becomes INTR, a maskable interrupt request signal, and LINT1/NMI becomes NMI, a nonmaskable interrupt. INTR and NMI are backward compatible with the signals of those names on the Pentium® processor. Both signals are asynchronous. These signals must be software configured via BIOS programming of the APIC register space to be used either as NMI/INTR or LINT[1:0]. Because the APIC is enabled by default after Reset, operation of these pins as LINT[1:0] is the default configuration. 2 LL_ID[1:0] O The LL_ID[1:0] signals are used to select the correct loadline slope for the processor. These signals are not connected to the processor die. A logic 0 is pulled to ground and a logic 1 is a no-connect on the Quad-Core Intel® Xeon® Processor 5300 Series package. LOCK# I/O LOCK# indicates to the system that a transaction must occur atomically. This signal must connect the appropriate pins of all processor FSB agents. For a locked sequence of transactions, LOCK# is asserted from the beginning of the first transaction to the end of the last transaction. When the priority agent asserts BPRI# to arbitrate for ownership of the processor FSB, it will wait until it observes LOCK# deasserted. This enables symmetric agents to retain ownership of the processor FSB throughout the bus locked operation and ensure the atomicity of lock. MCERR# I/O MCERR# (Machine Check Error) is asserted to indicate an unrecoverable error without a bus protocol violation. It may be driven by all processor FSB agents. 3 MCERR# assertion conditions are configurable at a system level. Assertion options are defined by the following options: • • • Enabled or disabled. Asserted, if configured, for internal errors along with IERR#. Asserted, if configured, by the request initiator of a bus transaction after it observes an error. • Asserted by any bus agent when it observes an error in a bus transaction. For more details regarding machine check architecture, refer to the Intel® 64 and IA-32 Intel® Architecture Software Developer’s Manual, Volume 3: System Programming Guide. MS_ID[1:0] PECI PROCHOT# O I/O O These signals are provided to indicate the Market Segment for the processor and may be used for future processor compatibility or for keying. These signals are not connected to the processor die. A logic 0 is pulled to ground and a logic 1 is a noconnect on the Quad-Core Intel® Xeon® Processor 5300 Series package. PECI is a proprietary one-wire bus interface that provides a communication channel between Intel processor and chipset components to external thermal monitoring devices. See Section 6.4 for more on the PECI interface. PROCHOT# (Processor Hot) will go active when the processor’s temperature monitoring sensor detects that the processor has reached its maximum safe operating temperature. This indicates that the Thermal Control Circuit (TCC) has been activated, if enabled. The TCC will remain active until shortly after the processor deasserts PROCHOT#. See Section 6.3.5 for more details. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 83 Signal Definitions Table 5-1. Name Signal Definitions (Sheet 6 of 7) Type Description Notes PWRGOOD I PWRGOOD (Power Good) is an input. The processor requires this signal to be a clean indication that all processor clocks and power supplies are stable and within their specifications. “Clean” implies that the signal will remain low (capable of sinking leakage current), without glitches, from the time that the power supplies are turned on until they come within specification. The signal must then transition monotonically to a high state. PWRGOOD can be driven inactive at any time, but clocks and power must again be stable before a subsequent rising edge of PWRGOOD. It must also meet the minimum pulse width specification in Table 2-19, and be followed by a 110 ms RESET# pulse. The PWRGOOD signal must be supplied to the processor; it is used to protect internal circuits against voltage sequencing issues. It should be driven high throughout boundary scan operation. 2 REQ[4:0]# I/O REQ[4:0]# (Request Command) must connect the appropriate pins of all processor FSB agents. They are asserted by the current bus owner to define the currently active transaction type. These signals are source synchronous to ADSTB[1:0]#. Refer to the AP[1:0]# signal description for details on parity checking of these signals. 3 RESET# I Asserting the RESET# signal resets all processors to known states and invalidates their internal caches without writing back any of their contents. For a power-on Reset, RESET# must stay active for at least 1 ms after VCC and BCLK have reached their proper specifications. On observing active RESET#, all FSB agents will deassert their outputs within two clocks. RESET# must not be kept asserted for more than 10 ms while PWRGOOD is asserted. A number of bus signals are sampled at the active-to-inactive transition of RESET# for power-on configuration. These configuration options are described in the Section 7.1. This signal does not have on-die termination and must be terminated on the system board. 3 RS[2:0]# I RS[2:0]# (Response Status) are driven by the response agent (the agent responsible for completion of the current transaction), and must connect the appropriate pins of all processor FSB agents. 3 RSP# I RSP# (Response Parity) is driven by the response agent (the agent responsible for completion of the current transaction) during assertion of RS[2:0]#, the signals for which RSP# provides parity protection. It must connect to the appropriate pins of all processor FSB agents. A correct parity signal is high if an even number of covered signals are low and low if an odd number of covered signals are low. While RS[2:0]# = 000, RSP# is also high, since this indicates it is not being driven by any agent guaranteeing correct parity. 3 SKTOCC# O SKTOCC# (Socket occupied) will be pulled to ground by the processor to indicate that the processor is present. There is no connection to the processor silicon for this signal. SMI# I SMI# (System Management Interrupt) is asserted asynchronously by system logic. On accepting a System Management Interrupt, processors save the current state and enter System Management Mode (SMM). An SMI Acknowledge transaction is issued, and the processor begins program execution from the SMM handler. If SMI# is asserted during the deassertion of RESET# the processor will tri-state its outputs. See Section 7.1. 2 STPCLK# I STPCLK# (Stop Clock), when asserted, causes processors to enter a low power StopGrant state. The processor issues a Stop-Grant Acknowledge transaction, and stops providing internal clock signals to all processor core units except the FSB and APIC units. The processor continues to snoop bus transactions and service interrupts while in Stop-Grant state. When STPCLK# is deasserted, the processor restarts its internal clock to all units and resumes execution. The assertion of STPCLK# has no effect on the bus clock; STPCLK# is an asynchronous input. 2 TCK I TCK (Test Clock) provides the clock input for the processor Test Bus (also known as the Test Access Port). TDI I TDI (Test Data In) transfers serial test data into the processor. TDI provides the serial input needed for JTAG specification support. TDO O TDO (Test Data Out) transfers serial test data out of the processor. TDO provides the serial output needed for JTAG specification support. TESTHI[11:0], I The TESTHI signals must use individual pull-up resistors. A matched resistor must be used for each Signal. 84 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Signal Definitions Table 5-1. Signal Definitions (Sheet 7 of 7) Name TESTIN1 TESTIN2 THERMTRIP# Type I I Description Notes Connect the TESTIN1 and TESTIN2 signals together, then terminate the net with a 51 Ω resistor to VTT. O Assertion of THERMTRIP# (Thermal Trip) indicates the processor junction temperature has reached a temperature beyond which permanent silicon damage may occur. Measurement of the temperature is accomplished through an internal thermal sensor. Upon assertion of THERMTRIP#, the processor will shut off its internal clocks (thus halting program execution) in an attempt to reduce the processor junction temperature. To protect the processor its core voltage (VCC) must be removed following the assertion of THERMTRIP#. Intel also recommends the removal of VTT when THERMTRIP# is asserted. Driving of the THERMTRIP# signals is enabled within 10 μs of the assertion of PWRGOOD and is disabled on de-assertion of PWRGOOD. Once activated, THERMTRIP# remains latched until PWRGOOD is de-asserted. While the de-assertion of the PWRGOOD signal will de-assert THERMTRIP#, if the processor’s junction temperature remains at or above the trip level, THERMTRIP# will again be asserted within 10 μs of the assertion of PWRGOOD. TMS I TMS (Test Mode Select) is a JTAG specification support signal used by debug tools. TRDY# I TRDY# (Target Ready) is asserted by the target to indicate that it is ready to receive a write or implicit writeback data transfer. TRDY# must connect the appropriate pins of all FSB agents. TRST# I TRST# (Test Reset) resets the Test Access Port (TAP) logic. TRST# must be driven low during power on Reset. VCCPLL I The Quad-Core Intel® Xeon® Processor 5300 Series implement an on-die PLL filter solution. The VCCPLL input is used as a PLL supply voltage. VCC_DIE_SENSE VCC_DIE_SENSE2 O VCC_DIE_SENSE and VCC_DIE_SENSE2 provides an isolated, low impedance connection to the processor core power and ground. This signal should be connected to the voltage regulator feedback signal, which insures the output voltage (that is, processor voltage) remains within specification. Please see the applicable platform design guide for implementation details. VID[6:1] O VID[6:1] (Voltage ID) pins are used to support automatic selection of power supply voltages (VCC). These are CMOS signals that are driven by the processor and must be pulled up through a resistor. Conversely, the voltage regulator output must be disabled prior to the voltage supply for these pins becomes invalid. The VID pins are needed to support processor voltage specification variations. See Table 2-3 for definitions of these pins. The VR must supply the voltage that is requested by these pins, or disable itself. VID_SELECT O VID_SELECT is an output from the processor which selects the appropriate VID table for the Voltage Regulator. This signal is not connected to the processor die. This signal is a no-connect on the Quad-Core Intel® Xeon® Processor 5300 Series package. VSS_DIE_SENSE VSS_DIE_SENSE2 O VSS_DIE_SENSE and VSS_DIE_SENSE2 provides an isolated, low impedance connection to the processor core power and ground. This signal should be connected to the voltage regulator feedback signal, which insures the output voltage (that is, processor voltage) remains within specification. Please see the applicable platform design guide for implementation details. VTT P The FSB termination voltage input pins. Refer to Table 2-12 for further details. VTT_OUT O The VTT_OUT signals are included in order to provide a local VTT for some signals that require termination to VTT on the motherboard. VTT_SEL O The VTT_SEL signal is used to select the correct VTT voltage level for the processor. VTT_SEL is a no-connect on the Quad-Core Intel® Xeon® Processor 5300 Series package. 1 Notes: 1. For this processor land on the Quad-Core Intel® Xeon® Processor 5300 Series, the maximum number of symmetric agents is one. Maximum number of priority agents is zero. 2. For this processor land on the Quad-Core Intel® Xeon® Processor 5300 Series, the maximum number of symmetric agents is two. Maximum number of priority agents is zero. 3. For this processor land on the Quad-Core Intel® Xeon® Processor 5300 Series, the maximum number of symmetric agents is two. Maximum number of priority agents is one. 4. Not all Quad-Core Intel® Xeon® Processor 5300 Series support signals A[37:36]#. Processors that support these signals will be outlined in the Quad-Core Intel® Xeon® Processor 5300 Series NDA Specification Update. § Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 85 Signal Definitions 86 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Thermal Specifications 6 Thermal Specifications 6.1 Package Thermal Specifications The Quad-Core Intel® Xeon® Processor 5300 Series requires a thermal solution to maintain temperatures within its operating limits. Any attempt to operate the processor outside these operating limits may result in permanent damage to the processor and potentially other components within the system. As processor technology changes, thermal management becomes increasingly crucial when building computer systems. Maintaining the proper thermal environment is key to reliable, long-term system operation. A complete solution includes both component and system level thermal management features. Component level thermal solutions can include active or passive heatsinks attached to the processor integrated heat spreader (IHS). Typical system level thermal solutions may consist of system fans combined with ducting and venting. This section provides data necessary for developing a complete thermal solution. For more information on designing a component level thermal solution, refer to the QuadCore Intel® Xeon® Processor 5300 Series Thermal/Mechanical Design Guidelines and the Quad-Core Intel® Xeon® Processor LV5318 in Embedded Applications Thermal/ Mechanical Design Guidelines. Note: The boxed processor will ship with a component thermal solution. Refer to Section 8 for details on the boxed processor. 6.1.1 Thermal Specifications To allow the optimal operation and long-term reliability of Intel processor-based systems, the processor must remain within the minimum and maximum case temperature (TCASE) specifications as defined by the applicable thermal profile. Thermal solutions not designed to provide this level of thermal capability may affect the long-term reliability of the processor and system. For more details on thermal/ mechanical design guidelines. The Quad-Core Intel® Xeon® Processor 5300 Series implement a methodology for managing processor temperatures which is intended to support acoustic noise reduction through fan speed control and to assure processor reliability. Selection of the appropriate fan speed is based on the relative temperature data reported by the processor’s Platform Environment Control Interface (PECI) bus as described in Section 6.4. The temperature reported over PECI is always a negative value and represents a delta below the onset of thermal control circuit (TCC) activation, as indicated by PROCHOT# (see Section 6.3, Processor Thermal Features). Systems that implement fan speed control must be designed to use this data. Systems that do not alter the fan speed only need to guarantee the case temperature meets the thermal profile specifications. The Quad-Core Intel® Xeon® Processor E5300 (see Figure 6-1; Table 6-2), QuadCore Intel® Xeon® Processor L5300 Series (see Figure 6-4; Table 6-9), and Quad-Core Intel® Xeon® Processor X5365 Series (see Figure 6-3; Table 6-7) support a single Thermal Profile. For these processors, it is expected that the Thermal Control Circuit (TCC) would only be activated for very brief periods of time when running the most Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 87 Thermal Specifications power-intensive applications. Refer to the Quad-Core Intel® Xeon® Processor 5300 Series Thermal/Mechanical Design Guidelinesfor details on system thermal solution design, thermal profiles and environmental considerations. For the Quad-Core Intel® Xeon® Processor X5300 Series, Intel has developed two thermal profiles, either of which can be implemented. Both ensure adherence to Intel reliability requirements. Thermal Profile A (see Figure 6-2; Table 6-4) is representative of a volumetrically unconstrained thermal solution (that is, industry enabled 2U heatsink). In this scenario, it is expected that the Thermal Control Circuit (TCC) would only be activated for very brief periods of time when running the most power intensive applications. Thermal Profile B (see Figure 6-2; Table 6-5) is indicative of a constrained thermal environment (that is, 1U form factor). Because of the reduced cooling capability represented by this thermal solution, the probability of TCC activation and performance loss is increased. Additionally, utilization of a thermal solution that does not meet Thermal Profile B will violate the thermal specifications and may result in permanent damage to the processor. Refer to the Quad-Core Intel® Xeon® Processor 5300 Series Thermal/Mechanical Design Guidelines for details on system thermal solution design, thermal profiles and environmental considerations. The upper point of the thermal profile consists of the Thermal Design Power (TDP) and the associated TCASE value. It should be noted that the upper point associated with the Quad-Core Intel® Xeon® Processor X5300 Series Thermal Profile B (x = TDP and y = TCASE_MAX_B @ TDP) represents a thermal solution design point. In actuality the processor case temperature will not reach this value due to TCC activation (see Figure 6-2 for Quad-Core Intel® Xeon® Processor X5300 Series). The lower point of the thermal profile consists of x = P_PROFILE_MIN and y = TCASE_MAX @ P_PROFILE_MIN. P_PROFILE_MIN is defined as the processor power at which TCASE, calculated from the thermal profile, is equal to 50°C. Analysis indicates that real applications are unlikely to cause the processor to consume maximum power dissipation for sustained time periods. Intel recommends that complete thermal solution designs target the Thermal Design Power (TDP), instead of the maximum processor power consumption. The Thermal Monitor feature is intended to help protect the processor in the event that an application exceeds the TDP recommendation for a sustained time period. For more details on this feature, refer to Section 6.3. To ensure maximum flexibility for future requirements, systems should be designed to the Flexible Motherboard (FMB) guidelines, even if a processor with lower power dissipation is currently planned. Thermal Monitor 1 and Thermal Monitor 2 feature must be enabled for the processor to remain within its specifications. Intel has developed thermal profiles specific to enable the Dual-Core Intel® Xeon® Processor LV 5318, to be used in environments compliant with NEBS* Level 3 ambient operating temperature requirements. At a minimum, NEBS Level 3 requires a nominal ambient operating temperature of 40°C, with short-term excursions to 55°C. “Shortterm” is defined as a maximum of 96 hours per instance, for a total maximum of 360 hours per year, and a maximum of 15 instances per year. To comply with these ambient operating temperature requirements, Intel has developed a corresponding Nominal Thermal Profile and Short-Term Thermal Profile. For normal operation, the processor must remain within the minimum and maximum case temperature (TCASE) specifications as defined by the Nominal Thermal Profile. For short-term operating conditions (maximum 96 hours per instance, maximum 360 hours per year, maximum of 15 instances per year), the processor may remain within the minimum and maximum TCASE, as defined by the Short-Term Thermal Profile. For environments that do not require NEBS Level 3 compliance, the processor must always remain within the minimum and maximum case temperature (TCASE) specifications as defined by the Nominal Thermal Profile. 88 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Thermal Specifications To provide greater flexibility in environmental conditions and thermal solution design, the Nominal Thermal Profile and the Short-Term Thermal Profile are each specified 5°C above the NEBS Level 3 ambient operating temperature requirements of 40°C nominal and 55°C short-term. The Nominal Thermal Profile is defined at an ambient operating temperature of 45°C, and the Short-Term Thermal Profile is defined at an ambient operating temperature of 60°C. Both of these thermal profiles ensure adherence to Intel reliability requirements. It is expected that the Thermal Control Circuit (TCC) would only be activated for very brief periods of time when running the most power intensive applications. Utilization of a thermal solution that exceeds the Short-Term Thermal Profile, or which operates at the Short-Term Thermal Profile for a duration longer than the specified limits will violate the thermal specifications and may result in permanent damage to the processor. Refer to the Quad-Core Intel® Xeon® Processor LV 5318 in Embedded Applications Thermal/ Mechanical Design Guidelines for details on system thermal solution design, thermal profiles and environmental considerations. Table 6-1. Quad-Core Intel® Xeon® Processor E5300 Series Thermal Specifications Core Frequency Launch to FMB Maximum Power (W) Thermal Design Power (W) Minimum TCASE (°C) Maximum TCASE (°C) 100 80 5 See Figure 6-1; Table 6-2 Notes 1, 2, 3, 4, 5, 6 Notes: 1. These values are specified at VCC_MAX for all processor frequencies. Systems must be designed to ensure the processor is not to be subjected to any static VCC and ICC combination wherein VCC exceeds VCC_MAX at specified ICC. Please refer to the loadline specifications in Section 2. 2. Maximum Power is the highest power the processor will dissipate, regardless of its VID. Maximum Power is measured at maximum TCASE. 3. Thermal Design Power (TDP) should be used for processor thermal solution design targets. TDP is not the maximum power that the processor can dissipate. TDP is measured at maximum TCASE. 4. These specifications are based on silicon characterization. 5. Power specifications are defined at all VIDs found in Table 2-3. The Quad-Core Intel® Xeon® Processor E5300 may be shipped under multiple VIDs for each frequency. 6. FMB, or Flexible Motherboard, guidelines provide a design target for meeting all planned processor frequency requirements. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 89 Thermal Specifications Figure 6-1.Quad-Core Intel® Xeon® Processor E5300 Series Thermal Profile 70 65 Thermal Profile Y = 0.293*x + 42.6 Tcase [C] 60 55 50 45 40 0 10 20 30 40 50 60 70 80 Power [W] Notes: 1. Please refer to Table 6-2 for discrete points that constitute the thermal profile. 2. Refer to the Quad-Core Intel® Xeon® Processor 5300 Series Thermal/Mechanical Design Guidelines for system and environmental implementation details. Table 6-2. Quad-Core Intel® Xeon® Processor E5300 Series Thermal Profile Table Power (W) 90 TCASE_MAX (° C) P_PROFILE_MIN=25.3 50.0 30 51.4 35 52.9 40 54.3 45 55.8 50 57.3 55 58.7 60 60.2 65 61.6 70 63.1 75 64.6 80 66.0 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Thermal Specifications Table 6-3. Quad-Core Intel® Xeon® Processor X5300 Series Thermal Specifications Core Frequency Launch to FMB Maximum Power (W) Thermal Design Power (W) Minimum TCASE (°C) Maximum TCASE (°C) 145 120 5 See Figure 6-2; Table 6-4; Table 6-5 Notes 1, 2, 3, 4, 5, 6 Notes: 1. These values are specified at VCC_MAX for all processor frequencies. Systems must be designed to ensure the processor is not to be subjected to any static VCC and ICC combination wherein VCC exceeds VCC_MAX at specified ICC. Please refer to the loadline specifications in Section 2. 2. Maximum Power is the highest power the processor will dissipate, regardless of its VID. Maximum Power is measured at maximum TCASE. 3. Thermal Design Power (TDP) should be used for processor thermal solution design targets. TDP is not the maximum power that the processor can dissipate. TDP is measured at maximum TCASE. 4. These specifications are based on silicon characterization. 5. Power specifications are defined at all VIDs found in Table 2-3. The Quad-Core Intel® Xeon® Processor X5300 Series may be shipped under multiple VIDs for each frequency. 6. FMB, or Flexible Motherboard, guidelines provide a design target for meeting all planned processor frequency requirements. Figure 6-2.Quad-Core Intel® Xeon® Processor X5300 Series Thermal Profiles TCASE_MAX is a thermal solution design point. In actuality, units will not significantly exceed TCASE_MAX_A due to TCC activation. 75 70 Tcase [C] 65 60 Thermal Profile B Y = 0.224*x + 43.1 55 Thermal Profile A Y = 0.171*x + 42.5 50 45 40 0 10 20 30 40 50 60 70 80 90 100 110 120 Pow e r [W] Notes: 1. Quad-Core Intel® Xeon® Processor X5300 Series Thermal Profile A is representative of a volumetrically unconstrained platform. Please refer to Table 6-4 for discrete points that constitute the thermal profile. 2. Implementation of Quad-Core Intel® Xeon® Processor X5300 Series Thermal Profile A should result in virtually no TCC activation. Furthermore, utilization of thermal solutions that do not meet processor QuadCore Intel® Xeon® Processor X5300 Series Thermal Profile A will result in increased probability of TCC activation and may incur measurable performance loss. (See Section 6.3 for details on TCC activation). 3. Quad-Core Intel® Xeon® Processor X5300 Series Thermal Profile B is representative of a volumetrically constrained platform. Please refer to Table 6-5 for discrete points that constitute the thermal profile. 4. Implementation of Thermal Profile B will result in increased probability of TCC activation and measurable performance loss. Furthermore, utilization of thermal solutions that do not meet Thermal Profile B do not meet the processor's thermal specifications and may result in permanent damage to the processor. 5. Refer to the Quad-Core Intel® Xeon® Processor 5300 Series Thermal/Mechanical Design Guidelines for system and environmental implementation details. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 91 Thermal Specifications Table 6-4. Table 6-5. 92 Quad-Core Intel® Xeon® Processor X5300 Series Thermal Profile A Table Power (W) TCASE_MAX (° C) P_PROFILE_MIN_A=43.9 50.0 45 50.2 50 51.1 55 51.9 60 52.8 65 53.6 70 54.5 75 55.3 80 56.2 85 57.0 90 57.9 95 58.7 100 59.6 105 60.5 110 61.3 115 62.2 120 63.0 Quad-Core Intel® Xeon® Processor X5300 Series Thermal Profile B Table Power (W) TCASE_MAX (° C) P_PROFILE_MIN_B=30.8 50.0 35 50.9 40 52.1 45 53.2 50 54.3 55 55.4 60 56.5 65 57.7 70 58.8 75 59.9 80 61.0 85 62.1 90 63.3 95 64.4 100 65.5 105 66.6 110 67.7 115 68.9 120 70.0 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Thermal Specifications Table 6-6. Quad-Core Intel® Xeon® Processor X5365 Series Thermal Specifications Core Frequency Launch to FMB Maximum Power (W) Thermal Design Power (W) Minimum TCASE (°C) Maximum TCASE (°C) 180 150 5 See Figure 6-3; Table 6-7 Notes 1, 2, 3, 4, 5, 6 Notes: 1. These values are specified at VCC_MAX for all processor frequencies. Systems must be designed to ensure the processor is not to be subjected to any static VCC and ICC combination wherein VCC exceeds VCC_MAX at specified ICC. Please refer to the loadline specifications in Section 2. 2. Maximum Power is the highest power the processor will dissipate, regardless of its VID. Maximum Power is measured at maximum TCASE. 3. Thermal Design Power (TDP) should be used for processor thermal solution design targets. TDP is not the maximum power that the processor can dissipate. TDP is measured at maximum TCASE. 4. These specifications are based on silicon characterization. 5. Power specifications are defined at all VIDs found in Table 2-3. The Quad-Core Intel® Xeon® Processor L5300 Series may be shipped under multiple VIDs for each frequency. 6. FMB, or Flexible Motherboard, guidelines provide a design target for meeting all planned processor frequency requirements. 7. 8. Figure 6-3. Quad-Core Intel® Xeon® Processor X5365 Series Thermal Profile 65 60 Thermal Profile Y = 0.187*x + 35.0 Tcase [C] 55 50 45 40 35 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Pow e r [W] Notes: 1. Please refer to Table 6-7 for discrete points that constitute the thermal profile. 2. Refer to the Quad-Core Intel® Xeon® Processor 5300 Series Thermal/Mechanical Design Guidelines for system and environmental implementation details. 3. 4. 5. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 93 Thermal Specifications Table 6-7. Table 6-8. Quad-Core Intel® Xeon® Processor X5365 Series Thermal Profile (Sheet 1 of 2) Power (W) TCASE_MAX (° C) P_PROFILE_MIN=50 44.3 55 45.3 60 46.2 65 47.1 70 48.1 75 49.0 80 49.9 85 50.9 90 51.8 95 52.7 100 53.7 105 54.6 110 55.5 115 56.5 120 57.4 125 58.3 130 59.3 135 60.2 140 61.1 145 62.1 150 63.0 Quad-Core Intel® Xeon® Processor L5300 Series Thermal Specifications Core Frequency Launch to FMB Maximum Power (W) Thermal Design Power (W) Minimum TCASE (°C) Maximum TCASE (°C) 65 50 5 See Figure 6-4; Table 6-9 Notes 1, 2, 3, 4, 5, 6 Notes: 1. These values are specified at VCC_MAX for all processor frequencies. Systems must be designed to ensure the processor is not to be subjected to any static VCC and ICC combination wherein VCC exceeds VCC_MAX at specified ICC. Please refer to the loadline specifications in Section 2. 2. Maximum Power is the highest power the processor will dissipate, regardless of its VID. Maximum Power is measured at maximum TCASE. 3. Thermal Design Power (TDP) should be used for processor thermal solution design targets. TDP is not the maximum power that the processor can dissipate. TDP is measured at maximum TCASE. 4. These specifications are based on silicon characterization. 5. Power specifications are defined at all VIDs found in Table 2-3. The Quad-Core Intel® Xeon® Processor L5300 Series may be shipped under multiple VIDs for each frequency. 6. FMB, or Flexible Motherboard, guidelines provide a design target for meeting all planned processor frequency requirements. 94 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Thermal Specifications Figure 6-4. Quad-Core Intel® Xeon® Processor L5300 Series Thermal Profile 65 60 Thermal Profile 55 Tcase [C] Y = 0.360*x + 42.0 50 45 40 0 10 20 30 40 50 Pow er [W] Notes: 1. Please refer to Table 6-9 for discrete points that constitute the thermal profile. 2. Refer to the Quad-Core Intel® Xeon® Processor 5300 Series Thermal/Mechanical Design Guidelines for system and environmental implementation details. 6.2 Table 6-9. Quad-Core Intel® Xeon® Processor L5300 Series Thermal Profile Power (W) TCASE_MAX (° C) P_PROFILE_MIN=22.2 50.0 25 51.0 30 52.8 35 54.6 40 56.4 45 58.2 50 60.0 Table 6-10.Quad-Core Intel® Xeon® Processor L5318 Thermal Specifications Core Frequency Launch to FMB Maximum Power (W) Thermal Design Power (W) Minimum TCASE (°C) Maximum TCASE (°C) 50 40 5 See Figure 6-5; Table 6-11 and Table 6-12 Notes 1, 2, 3, 4, 5, 6 Notes: 1. These values are specified at VCC_MAX for all processor frequencies. Systems must be designed to ensure the processor is not to be subjected to any static VCC and ICC combination wherein VCC exceeds VCC_MAX at specified ICC. Please refer to the loadline specifications in Section 2. 2. Maximum Power is the highest power the processor will dissipate, regardless of its VID. Maximum Power is measured at maximum TCASE. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 95 Thermal Specifications 3. 4. 5. 6. Figure 6-5. Thermal Design Power (TDP) should be used for processor thermal solution design targets. TDP is not the maximum power that the processor can dissipate. TDP is measured at maximum TCASE. These specifications are based on silicon characterization. Power specifications are defined at all VIDs found in Table 2-3. The Quad-Core Intel® Xeon® Processor L5300 Series may be shipped under multiple VIDs for each frequency. FMB, or Flexible Motherboard, guidelines provide a design target for meeting all planned processor frequency requirements. Quad-Core Intel® Xeon® Processor L5318 Thermal Profile Notes: 1. Please refer to Table 6-11 and Table 6-12 for discrete points that constitute the thermal profile. 2. Refer to the Quad-Core Intel® Xeon® Processor L5318 Thermal/Mechanical Design Guidelines for system and environmental implementation details. 3. The Nominal Thermal Profile must be used for all normal operating conditions, or for products that do not require NEBS Level 3 compliance. 4. The Short-Term Thermal Profile may only be used for short-term excursions to higher ambient operating temperatures, not to exceed 96 hours per instance, 360 hours per year, and a maximum of 15 instances per year, as compliant with NEBS Level 3. 5. Implementation of either thermal profile should result in virtually no TCC activation. 6. Utilization of a thermal solution that exceeds the Short-Term Thermal Profile, or which operates at the Short-Term Thermal Profile for a duration longer than the limits specified in Note 3 above, do not meet the processor’s thermal specifications and may result in permanent damage to the processor. 96 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Thermal Specifications Table 6-11. Quad-Core Intel® Xeon® Processor L5318 Nominal Thermal Profile Power (W) TCASE_MAX (° C) P_PROFILE_MIN=0 45.0 5 48.4 10 51.8 15 55.2 20 58.6 25 62.0 30 65.4 35 68.8 40 72.2 Table 6-12. Quad-Core Intel® Xeon® Processor L5318 Short Term Thermal Profile Power (W) 6.2.1 TCASE_MAX (° C) P_PROFILE_MIN=0 60.0 5 63.4 10 66.8 15 70.2 20 73.6 25 77.0 30 80.4 35 83.8 40 87.2 Thermal Metrology The minimum and maximum case temperatures (TCASE) are specified in Table 6-1, through Table 6-7 and are measured at the geometric top center of the processor integrated heat spreader (IHS). Figure 6-6 illustrates the location where TCASE Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 97 Thermal Specifications temperature measurements should be made. For detailed guidelines on temperature measurement methodology, refer to the Quad-Core Intel® Xeon® Processor 5300 Series Thermal/Mechanical Design Guidelines Figure 6-6. Case Temperature (TCASE) Measurement Location Note: Figure is not to scale and is for reference only. 6.3 Processor Thermal Features 6.3.1 Thermal Monitor Features Quad-Core Intel® Xeon® Processor 5300 Series provide two thermal monitor features, Thermal Monitor (TM1) and Enhanced Thermal Monitor (TM2). The TM1 and TM2 must both be enabled in BIOS for the processor to be operating within specifications. When both are enabled, TM2 will be activated first and TM1 will be added if TM2 is not effective. 6.3.2 Thermal Monitor (TM1) The Thermal Monitor (TM1) feature helps control the processor temperature by activating the Thermal Control Circuit (TCC) when the processor silicon reaches its maximum operating temperature. The TCC reduces processor power consumption as needed by modulating (starting and stopping) the internal processor core clocks. The temperature at which Thermal Monitor activates the thermal control circuit is not user 98 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Thermal Specifications configurable and is not software visible. Bus traffic is snooped in the normal manner, and interrupt requests are latched (and serviced during the time that the clocks are on) while the TCC is active. When the TM1 is enabled, and a high temperature situation exists (that is, TCC is active), the clocks will be modulated by alternately turning off and on at a duty cycle specific to the processor (typically 30 - 50%). Cycle times are processor speed dependent and will decrease as processor core frequencies increase. A small amount of hysteresis has been included to prevent rapid active/inactive transitions of the TCC when the processor temperature is near its maximum operating temperature. Once the temperature has dropped below the maximum operating temperature, and the hysteresis timer has expired, the TCC goes inactive and clock modulation ceases. With thermal solutions designed to the Quad-Core Intel® Xeon® Processor E5300 Thermal Profile, the Quad-Core Intel® Xeon® Processor L5300 Series Thermal Profile, Quad-Core Intel® Xeon® Processor X5365 Series Thermal Profile, or Quad-Core Intel® Xeon® Processor X5300 Series Thermal Profile A it is anticipated that the TCC would only be activated for very short periods of time when running the most power intensive applications. The processor performance impact due to these brief periods of TCC activation is expected to be so minor that it would be immeasurable. A thermal solution that is designed to Quad-Core Intel® Xeon® Processor X5300 Series Thermal Profile B may cause a noticeable performance loss due to increased TCC activation. Thermal Solutions that exceed Thermal Profile B will exceed the maximum temperature specification and affect the long-term reliability of the processor. In addition, a thermal solution that is significantly under designed may not be capable of cooling the processor even when the TCC is active continuously Refer to the Quad-Core Intel® Xeon® Processor 5300 Series Thermal/Mechanical Design Guidelines for information on designing a thermal solution. The duty cycle for the TCC, when activated by the TM1, is factory configured and cannot be modified. The TM1 does not require any additional hardware, software drivers, or interrupt handling routines. 6.3.3 Thermal Monitor 2 The Quad-Core Intel® Xeon® Processor 5300 Series adds support for an Enhanced Thermal Monitor capability known as Thermal Monitor 2 (TM2). This mechanism provides an efficient means for limiting the processor temperature by reducing the power consumption within the processor. TM2 requires support for dynamic VID transitions in the platform. When TM2 is enabled, and a high temperature situation is detected, the Thermal Control Circuit (TCC) will be activated for all processor cores. The TCC causes the processor to adjust its operating frequency (via the bus multiplier) and input voltage (via the VID signals). This combination of reduced frequency and VID results in a reduction to the processor power consumption. A processor enabled for TM2 includes two operating points, each consisting of a specific operating frequency and voltage, which is identical for both processor dies. The first operating point represents the normal operating condition for the processor. Under this condition, the core-frequency-to-system-bus multiplier utilized by the processor is that contained in the CLOCK_FLEX_MAX MSR and the VID that is specified in Table 2-3. The second operating point consists of both a lower operating frequency and voltage. The lowest operating frequency is determined by the lowest supported bus ratio (1/6 for the Quad-Core Intel® Xeon® Processor 5300 Series). When the TCC is activated, the processor automatically transitions to the new frequency. This transition occurs Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 99 Thermal Specifications rapidly, on the order of 5 µs. During the frequency transition, the processor is unable to service any bus requests, and consequently, all bus traffic is blocked. Edge-triggered interrupts will be latched and kept pending until the processor resumes operation at the new frequency. Once the new operating frequency is engaged, the processor will transition to the new core operating voltage by issuing a new VID code to the voltage regulator. The voltage regulator must support dynamic VID steps in order to support Thermal Monitor 2. During the voltage change, it will be necessary to transition through multiple VID codes to reach the target operating voltage. Each step will be one VID table entry (see Table 2-3). The processor continues to execute instructions during the voltage transition. Operation at the lower voltage reduces the power consumption of the processor. A small amount of hysteresis has been included to prevent rapid active/inactive transitions of the TCC when the processor temperature is near its maximum operating temperature. Once the temperature has dropped below the maximum operating temperature, and the hysteresis timer has expired, the operating frequency and voltage transition back to the normal system operating point. Transition of the VID code will occur first, in order to insure proper operation once the processor reaches its normal operating frequency. Refer to Figure 6-7 for an illustration of this ordering. Figure 6-7. Thermal Monitor 2 Frequency and Voltage Ordering TTM2 Temperature fMAX fTM2 Frequency VNOM VTM2 Vcc Time T(hysterisis) The PROCHOT# signal is asserted when a high temperature situation is detected, regardless of whether TM1 or TM2 is enabled. 6.3.4 On-Demand Mode The processor provides an auxiliary mechanism that allows system software to force the processor to reduce its power consumption. This mechanism is referred to as “OnDemand” mode and is distinct from the Thermal Monitor 1 and Thermal Monitor 2 features. On-Demand mode is intended as a means to reduce system level power consumption. Systems utilizing the Quad-Core Intel® Xeon® Processor 5300 Series must not rely on software usage of this mechanism to limit the processor temperature. If bit 4 of the IA32_CLOCK_MODULATION MSR is set to a ‘1’, the processor will immediately reduce its power consumption via modulation (starting and stopping) of the internal core clock, independent of the processor temperature. When using OnDemand mode, the duty cycle of the clock modulation is programmable via bits 3:1 of 100 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Thermal Specifications the same IA32_CLOCK_MODULATION MSR. In On-Demand mode, the duty cycle can be programmed from 12.5% on/ 87.5% off to 87.5% on/12.5% off in 12.5% increments. On-Demand mode may be used in conjunction with the Thermal Monitor; however, if the system tries to enable On-Demand mode at the same time the TCC is engaged, the factory configured duty cycle of the TCC will override the duty cycle selected by the On-Demand mode. 6.3.5 PROCHOT# Signal An external signal, PROCHOT# (processor hot) is asserted when the processor die temperature of any processor cores has reached its factory configured trip point. If Thermal Monitor is enabled (note that Thermal Monitor must be enabled for the processor to be operating within specification), the TCC will be active when PROCHOT# is asserted. The processor can be configured to generate an interrupt upon the assertion or de-assertion of PROCHOT#. Refer to the Intel® 64 and IA-32 Architectures Software Developer’s Manual and the Conroe and Woodcrest Processor Family BIOS Writer’s Guide for specific register and programming details. PROCHOT# is designed to assert at or a few degrees higher than maximum TCASE (as specified by Thermal Profile A) when dissipating TDP power, and cannot be interpreted as an indication of processor case temperature. This temperature delta accounts for processor package, lifetime and manufacturing variations and attempts to ensure the Thermal Control Circuit is not activated below maximum TCASE when dissipating TDP power. There is no defined or fixed correlation between the PROCHOT# trip temperature, or the case temperature. Thermal solutions must be designed to the processor specifications and cannot be adjusted based on experimental measurements of TCASE, or PROCHOT#. 6.3.6 FORCEPR# Signal The FORCEPR# (force power reduction) input can be used by the platform to cause the Quad-Core Intel® Xeon® Processor 5300 Series to activate the TCC. If the processor supports Thermal Monitor 2 (TM2), and has Thermal Monitor 2 and Thermal Monitor (TM) properly enabled, assertion of the FORCEPR# signal will immediately activate Thermal Monitor 2. If the processor does not support Thermal Monitor 2, but has Thermal Monitor properly enabled, FORCEPR# signal assertion will cause Thermal Monitor to become active. Please refer to the Quad-Core Intel® Xeon® Processor 5300 Series NDA Specification Update to determine which processors support TM2 and Conroe and Woodcrest Processor Family BIOS Writer’s Guide for details on enabling these capabilities. Assertion of the FORCEPR# signal will activate TCC for all processor cores. The TCC will remain active until the system deasserts FORCEPR#. FORCEPR# is an asynchronous input, which can be employed to thermally protect other system components. To use the voltage regulator (VR) as an example, TCC circuit activation will reduce the current consumption of the processor and the corresponding temperature of the VR. It should be noted that assertion of FORCEPR# does not automatically assert PROCHOT#. As mentioned previously, the PROCHOT# signal is asserted when a high temperature situation is detected. A minimum pulse width of 500 µs is recommended when FORCEPR# is asserted by the system. Sustained activation of the FORCEPR# signal may cause noticeable platform performance degradation. Refer to the appropriate platform design guidelines for details on implementing the FORCEPR# signal feature. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 101 Thermal Specifications 6.3.7 THERMTRIP# Signal Regardless of whether or not TM1 or TM2 is enabled, in the event of a catastrophic cooling failure, the processor will automatically shut down when the silicon has reached an elevated temperature (refer to the THERMTRIP# definition in Table 5-1). At this point, the FSB signal THERMTRIP# will go active and stay active as described in Table 5-1. THERMTRIP# activation is independent of processor activity and does not generate any bus cycles. Intel also recommends the removal of VTT. 6.4 Platform Environment Control Interface (PECI) 6.4.1 Introduction PECI offers an interface for thermal monitoring of Intel processor and chipset components. It uses a single wire, thus alleviating routing congestion issues. Figure 6-8 shows an example of the PECI topology in a system with Quad-Core Intel® Xeon® Processor 5300 Series. PECI uses CRC checking on the host side to ensure reliable transfers between the host and client devices. Also, data transfer speeds across the PECI interface are negotiable within a wide range (2 Kbps to 2 Mbps). The PECI interface on Quad-Core Intel® Xeon® Processor 5300 Series is disabled by default and must be enabled through BIOS. More information on this can be found in the Conroe and Woodcrest Processor Family BIOS Writer’s Guide. Figure 6-8. PECI Topology Q u a d -C o re In te l® X e o n ® P ro c e s s o r 5 3 0 0 S e rie s (S o c k e t 0 ) G5 PEC I H ost C o n tro lle r D o m a in 0 0 x 3 0 D o m a in 1 Q u a d -C o re In te l® X e o n ® P ro c e s s o r 5 3 0 0 S e rie s (S o c k e t 1 ) G5 6.4.1.1 0 x 3 0 0 x 3 1 D o m a in 0 0 x 3 1 D o m a in 1 TCONTROL and TCC Activation on PECI-Based Systems Fan speed control solutions based on PECI utilize a TCONTROL value stored in the processor IA32_TEMPERATURE_TARGET MSR. This MSR uses the same offset temperature format as PECI, though it contains no sign bit. Thermal management devices should infer the TCONTROL value as negative. Thermal management algorithms should utilize the relative temperature value delivered over PECI in conjunction with the MSR value to control or optimize fan speeds. Figure 6-9 shows a conceptual fan control diagram using PECI temperatures. 102 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Thermal Specifications Figure 6-9. Conceptual Fan Control Diagram For A PECI-Based Platform TCONTROL Setting TCC Activation Temperature Max PECI = 0 Fan Speed (RPM) PECI = -10 Min PECI = -20 Temperature (not intended to depict actual implementation) 6.4.1.2 Processor Thermal Data Sample Rate and Filtering The DTS provides an improved capability to monitor device hot spots, which inherently leads to more varying temperature readings over short time intervals. The DTS sample interval range can be modified, and a data filtering algorithm can be activated to help moderate this. The DTS sample interval range is 82 ms (default) to 20 ms (max). This value can be set in BIOS. To reduce the sample rate requirements on PECI and improve thermal data stability vs. time the processor DTS also implements an averaging algorithm that filters the incoming data. This is an alpha-beta filter with coefficients of 0.5, and is expressed mathematically as: Current_filtered_temp = (Previous_filtered_temp / 2) + (new_sensor_temp / 2). This filtering algorithm is fixed and cannot be changed. It is on by default and can be turned off in BIOS. Host controllers should utilize the min/max sample times to determine the appropriate sample rate based on the controller's fan control algorithm and targeted response rate. The key items to take into account when settling on a fan control algorithm are the DTS sample rate, whether the temperature filter is enabled, how often the PECI host will poll the processor for temperature data, and the rate at which fan speed is changed. Depending on the designer’s specific requirements the DTS sample rate and alpha-beta filter may have no effect on the fan control algorithm. 6.4.2 PECI Specifications 6.4.2.1 PECI Device Address The PECI device address for socket 0 is 0x30 and socket 1 is 0x31. Please note that each address also supports two domains (Domain 0 and Domain 1). For more information on PECI domains, please refer to the Platform Environment Control Interface Specification. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 103 Thermal Specifications 6.4.2.2 PECI Command Support PECI command support is covered in detail in Platform Environment Control Interface Specification. Please refer to this document for details on supported PECI command function and codes 6.4.2.3 PECI Fault Handling Requirements PECI is largely a fault tolerant interface, including noise immunity and error checking improvements over other compatible industry standard interfaces. The PECI client is as reliable as the device that it is embedded within, and thus given operating conditions that fall under the specification, the PECI client will always respond to requests and the protocol itself can be relied upon to detect any transmission failures. There are, however, certain scenarios where PECI is known to be unresponsive. Prior to a power on RESET# and during RESET# assertion, PECI is not guaranteed to provide reliable thermal data. System designs should implement a default power-on condition that ensures proper processor operation during the time frame when reliable data is not available via PECI. To protect platforms from potential operational or safety issues due to an abnormal condition on PECI, the PECI host controller should take action to protect the system from possible damage. It is recommended that the PECI host controller take appropriate action to protect the client processor device if valid temperature readings have not been obtained in response to three consecutive gettemp()s or for a one second time interval. The PECI host controller may also implement an alert to software in the event of a critical or continuous fault condition. 6.4.2.4 PECI GetTemp0() and GetTemp1() Error Code Support The error codes supported for the processor GetTemp0() and GetTemp1() command are listed in Table 6-13 below: Table 6-13. GetTemp0() and GetTemp1() Error Codes Error Code Description 0x8000 General sensor error 0x8002 Sensor is operational, but has detected a temperature below its operational range (underflow). § 104 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Features 7 Features 7.1 Power-On Configuration Options Several configuration options can be configured by hardware. Quad-Core Intel® Xeon® Processor 5300 Series sample its hardware configuration at reset, on the active-toinactive transition of RESET#. For specifics on these options, please refer to Table 7-1. The sampled information configures the processor for subsequent operation. These configuration options cannot be changed except by another reset. All resets reconfigure the processor, for reset purposes, the processor does not distinguish between a “warm” reset (PWRGOOD signal remains asserted) and a “power-on” reset. Table 7-1. Power-On Configuration Option Lands Configuration Option Land Name Notes SMI# 1,2,3 Execute BIST (Built-In Self Test) A3# 1,2 Disable MCERR# observation A9# 1,2 A10# 1,2 BR[1:0]# 1,2 Output tri state Disable BINIT# observation Symmetric agent arbitration ID Notes: 1. 2. 3. Asserting this signal during RESET# will select the corresponding option. Address lands not identified in this table as configuration options should not be asserted during RESET#. Requires de-assertion of PWRGOOD. Disabling of any of the cores within the Quad-Core Intel® Xeon® Processor 5300 Series must be handled by configuring the EXT_CONFIG Model Specific Register (MSR). This MSR will allow for the disabling of a single core per die within the Quad-Core Intel® Xeon® Processor 5300 Series package. Additional details can be found in the Conroe and Woodcrest Processor Family BIOS Writer’s Guide. 7.2 Clock Control and Low Power States Quad-Core Intel® Xeon® Processor 5300 Series support the Extended HALT state (also referred to as C1E) in addition to the HALT state and Stop-Grant state to reduce power consumption by stopping the clock to internal sections of the processor, depending on each particular state. See Figure 7-1 for a visual representation of the processor low power states. The Extended HALT state is a lower power state than the HALT state or Stop Grant state. The Extended HALT state must be enabled via the BIOS for the processor to remain within its specifications. Refer to the Conroe and Woodcrest Processor Family BIOS Writer’s Guide. For processors that are already running at the lowest bus to core frequency ratio for its nominal operating point, the processor will transition to the HALT state instead of the Extended HALT state. The Stop Grant state requires chipset and BIOS support on multiprocessor systems. In a multiprocessor system, all the STPCLK# signals are bussed together, thus all processors are affected in unison. When the STPCLK# signal is asserted, the processor enters the Stop Grant state, issuing a Stop Grant Special Bus Cycle (SBC) for each processor. The chipset needs to account for a variable number of processors asserting Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 105 Features the Stop Grant SBC on the bus before allowing the processor to be transitioned into one of the lower processor power states. Refer to the applicable chipset specification and the Conroe and Woodcrest Processor Family BIOS Writer’s Guide for more information. 7.2.1 Normal State This is the normal operating state for the processor. 7.2.2 HALT or Extended HALT State The Extended HALT state (C1E) is enabled via the BIOS. Refer to the Conroe and Woodcrest Processor Family BIOS Writer’s Guide. The Extended HALT state must be enabled for the processor to remain within its specifications. The Extended HALT state requires support for dynamic VID transitions in the platform. 7.2.2.1 HALT State HALT is a low power state entered when the processor has executed the HALT or MWAIT instruction. When one of the processor cores execute the HALT or MWAIT instruction, that processor core is halted; however, the other processor continues normal operation. The processor will transition to the Normal state upon the occurrence of SMI#, BINIT#, INIT#, LINT[1:0] (NMI, INTR), or an interrupt delivered over the front side bus. RESET# will cause the processor to immediately initialize itself. The return from a System Management Interrupt (SMI) handler can be to either Normal Mode or the HALT state. See the Intel® 64 and IA-32 Intel® Architecture Software Developer's Manual, Volume III: System Programming Guide for more information. The system can generate a STPCLK# while the processor is in the HALT state. When the system deasserts STPCLK#, the processor will return execution to the HALT state. While in HALT state, the processor will process front side bus snoops and interrupts. 7.2.2.2 Extended HALT State Extended HALT state is a low power state entered when all four processor cores have executed the HALT or MWAIT instructions and Extended HALT state has been enabled via the BIOS. When one of the processor cores executes the HALT instruction, that processor core is halted; however, the other processor cores continue normal operation. The Extended HALT state is a lower power state than the HALT state or Stop Grant state. The Extended HALT state must be enabled for the processor to remain within its specifications. The processor will automatically transition to a lower core frequency and voltage operating point before entering the Extended HALT state. Note that the processor FSB frequency is not altered; only the internal core frequency is changed. When entering the low power state, the processor will first switch to the lower bus to core frequency ratio and then transition to the lower voltage (VID). While in the Extended HALT state, the processor will process bus snoops. The processor exits the Extended HALT state when a break event occurs. When the processor exits the Extended HALT state, it will first transition the VID to the original value and then change the bus to core frequency ratio back to the original value. 106 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Features Table 7-2. Extended HALT Maximum Power B-3 Stepping G-0 Stepping FSB Speed (MHz) TCASE (°C) Max (W) TCASE (°C) PEXTENDED_HALT QuadCore Intel® Xeon® Processor E5300 Series 1333 50 30/34 1066 50 30/34 PEXTENDED_HALT QuadCore Intel® Xeon® Processor X5300 Series 1333 50 PEXTENDED_HALT QuadCore Intel® Xeon® Processor X5365 Series 1333 PEXTENDED_HALT QuadCore Intel® Xeon® Processor L5300 Series PEXTENDED_HALT QuadCore Intel® Xeon® Processor L5318 Symbol Max (W) Notes 40/50 25/34 1,2,3 50 30/34 1,2 50 40 25 1 50 50 40 25 1 1333 50 24 50 24 1 1066 50 24 50 24 1 1066 50 24 50 24 1 Notes: 1. These specifications are based on silicon characterization. 2. Processors running in the lowest bus ratio will enter the HALT state when the processor has executed the HALT and MWAIT instruction since the processor is already in the lowest core frequency and voltage operating point. Values represent SKUs with Extended HALT state (25W/30W) and without Extended HALT state (34W). 3. G-0 stepping SKUs with Extended HALT state are specified at TCASE = 40°C. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 107 Features Figure 7-1. Stop Clock State Machine HALT or MWAIT Instruction and HALT Bus Cycle Generated Normal State Normal execution S De TPC -a LK ss # er te d STPCLK# De-asserted S A s TP C se L rte K# d STPCLK# Asserted INIT#, BINIT#, INTR, NMI, SMI#, RESET#, FSB interrupts Extended HALT or HALT State BCLK running Snoops and interrupts allowed Snoop Event Occurs Snoop Event Serviced Extended HALT Snoop or HALT Snoop State BCLK running Service snoops to caches Stop Grant State BCLK running Snoops and interrupts allowed 7.2.3 Snoop Event Occurs Snoop Event Serviced Stop Grant Snoop State BCLK running Service snoops to caches Stop-Grant State When the STPCLK# pin is asserted, the Stop-Grant state of the processor is entered 20 bus clocks after the response phase of the processor issued Stop Grant Acknowledge special bus cycle. The Quad-Core Intel® Xeon® Processor 5300 Series will issue two Stop Grant Acknowledge special bus cycles, once for each die. Once the STPCLK# pin has been asserted, it may only be deasserted once the processor is in the Stop Grant state. All processor cores will enter the Stop-Grant state once the STPCLK# pin is asserted. Additionally, all processor cores must be in the Stop Grant state before the deassertion of STPCLK#. Since the AGTL+ signal pins receive power from the front side bus, these pins should not be driven (allowing the level to return to VTT) for minimum power drawn by the termination resistors in this state. In addition, all other input pins on the front side bus should be driven to the inactive state. BINIT# will not be serviced while the processor is in Stop-Grant state. The event will be latched and can be serviced by software upon exit from the Stop Grant state. RESET# will cause the processor to immediately initialize itself, but the processor will stay in Stop-Grant state. A transition back to the Normal state will occur with the deassertion of the STPCLK# signal. 108 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Features A transition to the Grant Snoop state will occur when the processor detects a snoop on the front side bus (see Section 7.2.4.1). While in the Stop-Grant state, SMI#, INIT#, BINIT# and LINT[1:0] will be latched by the processor, and only serviced when the processor returns to the Normal state. Only one occurrence of each event will be recognized upon return to the Normal state. While in Stop-Grant state, the processor will process snoops on the front side bus and it will latch interrupts delivered on the front side bus. The PBE# signal can be driven when the processor is in Stop-Grant state. PBE# will be asserted if there is any pending interrupt latched within the processor. Pending interrupts that are blocked by the EFLAGS.IF bit being clear will still cause assertion of PBE#. Assertion of PBE# indicates to system logic that it should return the processor to the Normal state. 7.2.4 Extended HALT Snoop or HALT Snoop State, Stop Grant Snoop State The Extended HALT Snoop state is used in conjunction with the Extended HALT state. If the Extended HALT state is not enabled in the BIOS, the default Snoop state entered will be the HALT Snoop state. Refer to the sections below for details on HALT Snoop state, Stop Grant Snoop state and Extended HALT Snoop state. 7.2.4.1 HALT Snoop State, Stop Grant Snoop State The processor will respond to snoop or interrupt transactions on the front side bus while in Stop-Grant state or in HALT state. During a snoop or interrupt transaction, the processor enters the HALT/Grant Snoop state. The processor will stay in this state until the snoop on the front side bus has been serviced (whether by the processor or another agent on the front side bus) or the interrupt has been latched. After the snoop is serviced or the interrupt is latched, the processor will return to the Stop-Grant state or HALT state, as appropriate. 7.2.4.2 Extended HALT Snoop State The Extended HALT Snoop state is the default Snoop state when the Extended HALT state is enabled via the BIOS. The processor will remain in the lower bus to core frequency ratio and VID operating point of the Extended HALT state. While in the Extended HALT Snoop state, snoops and interrupt transactions are handled the same way as in the HALT Snoop state. After the snoop is serviced or the interrupt is latched, the processor will return to the Extended HALT state. 7.3 Enhanced Intel SpeedStep® Technology Quad-Core Intel® Xeon® Processor 5300 Series support Enhanced Intel SpeedStep® Technology. This technology enables the processor to switch between multiple frequency and voltage points, which results in platform power savings. Enhanced Intel SpeedStep Technology requires support for dynamic VID transitions in the platform. Switching between voltage/frequency states is software controlled. For more configuration details also refer to the Conroe and Woodcrest Processor Family BIOS Writer’s Guide. Note: Not all Quad-Core Intel® Xeon® Processor 5300 Series are capable of supporting Enhanced Intel SpeedStep Technology. More details on which processor frequencies will Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 109 Features support this feature will be provided in future releases of the Quad-Core Intel® Xeon® Processor 5300 Series NDA Specification Update when available. Enhanced Intel SpeedStep Technology creates processor performance states (P-states) or voltage/frequency operating points. P-states are lower power capability states within the Normal state as shown in Figure 7-1. Enhanced Intel SpeedStep Technology enables real-time dynamic switching between frequency and voltage points. It alters the performance of the processor by changing the bus to core frequency ratio and voltage. This allows the processor to run at different core frequencies and voltages to best serve the performance and power requirements of the processor and system. The Quad-Core Intel® Xeon® Processor 5300 Series have hardware logic that coordinates the requested voltage (VID) between the processor cores. The highest voltage that is requested from the four processor cores is selected for that processor package. Note that the front side bus is not altered; only the internal core frequency is changed. In order to run at reduced power consumption, the voltage is altered in step with the bus ratio. The following are key features of Enhanced Intel SpeedStep Technology: • Multiple voltage/frequency operating points provide optimal performance at reduced power consumption. • Voltage/frequency selection is software controlled by writing to processor MSR’s (Model Specific Registers), thus eliminating chipset dependency. — If the target frequency is higher than the current frequency, VCC is incremented in steps (+12.5 mV) by placing a new value on the VID signals and the processor shifts to the new frequency. Note that the top frequency for the processor can not be exceeded. — If the target frequency is lower than the current frequency, the processor shifts to the new frequency and VCC is then decremented in steps (-12.5 mV) by changing the target VID through the VID signals. See the Conroe and Woodcrest Processor Family BIOS Writer’s Guide for specific information to enable and configure Enhanced Intel SpeedStep Technology in BIOS. § 110 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Boxed Processor Specifications 8 Boxed Processor Specifications 8.1 Introduction Intel boxed processors are intended for system integrators who build systems from components available through distribution channels. The Quad-Core Intel® Xeon® Processor 5300 Series will be offered as an Intel boxed processor. Intel will offer the Quad-Core Intel® Xeon® Processor 5300 Series boxed processor with two heat sink configurations available for each processor frequency: 1U passive/ 3U+ active combination solution and a 2U passive only solution. The 1U passive/3U+ active combination solution is based on a 1U passive heat sink with a removable fan that will be pre-attached at shipping. This heat sink solution is intended to be used as either a 1U passive heat sink, or a 3U+ active heat sink. Although the active combination solution with removable fan mechanically fits into a 2U keepout, its use is not recommended in that configuration. The 1U passive/3U+ active combination solution in the active fan configuration is primarily designed to be used in a pedestal chassis where sufficient air inlet space is present and strong side directional airflow is not an issue. The 1U passive/3U+ active combination solution with the fan removed and the 2U passive thermal solution require the use of chassis ducting and are targeted for use in rack mount or pedestal servers. The retention solution used for these products is called the Common Enabling Kit, or CEK. The CEK base is compatible with both thermal solutions and uses the same hole locations as the Dual-Core Intel® Xeon® processor 5100 series. The 1U passive/3U+ active combination solution will utilize a removable fan capable of 4-pin pulse width modulated (PWM) control. Use of a 4-pin PWM controlled active thermal solution helps customers meet acoustic targets in pedestal platforms through the motherboards’s ability to directly control the RPM of the processor heat sink fan. See Section 8.3 for more details on fan speed control, and see Section 6.4 for more on the PWM and PECI interface along with Digital Thermal Sensors (DTS). Figure 8-1 through Figure 8-3 are representations of the two heat sink solutions. Figure 8-1. Boxed Quad-Core Intel® Xeon® Processor 5300 Series 1U Passive/3U+ Active Combination Heat Sink (With Removable Fan) Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 111 Boxed Processor Specifications Figure 8-2. Boxed Quad-Core Intel® Xeon® Processor 5300 Series 2U Passive Heat Sink Figure 8-3. 2U Passive Quad-Core Intel® Xeon® Processor 5300 Series Processor Thermal Solution (Exploded View) Heat sink screws Heat sink screw springs Heat sink Heat sink standoffs Thermal Interface Material Motherboard and processor Protective Tape CEK spring Chassis pan Note: 1. The heat sinks and fan assemblies represented in Figure 8-1, Figure 8-2, and Figure 8-3 are for reference only, and may not represent the final boxed processor heat sinks. 2. The screws, springs, and standoffs will be captive to the heat sink. This image shows all of the components in an exploded view. 3. It is intended that the CEK spring will ship with the base board and be pre-attached prior to shipping. 112 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Boxed Processor Specifications 8.2 Mechanical Specifications This section documents the mechanical specifications of the boxed processor. 8.2.1 Boxed Processor Heat Sink Dimensions (CEK) The boxed processor will be shipped with an unattached thermal solution. Clearance is required around the thermal solution to ensure unimpeded airflow for proper cooling. The physical space requirements and dimensions for the boxed processor and assembled heat sink are shown in Figure 8-4 through Figure 8-8. Figure 8-9 through Figure 8-10 are the mechanical drawings for the 4-pin board fan header and 4-pin connector used for the active CEK fan heat sink solution. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 113 Boxed Processor Specifications Figure 8-4. 114 Top Side Board Keepout Zones (Part 1) Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Boxed Processor Specifications Figure 8-5. Top Side Board Keepout Zones (Part 2) Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 115 Boxed Processor Specifications Figure 8-6. 116 Bottom Side Board Keepout Zones Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Boxed Processor Specifications Figure 8-7. Board Mounting-Hole Keepout Zones Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 117 Boxed Processor Specifications Figure 8-8. 118 Volumetric Height Keep-Ins Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Boxed Processor Specifications Figure 8-9. 4-Pin Fan Cable Connector (For Active CEK Heat Sink) Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 119 Boxed Processor Specifications Figure 8-10. 4-Pin Base Board Fan Header (For Active CEK Heat Sink) 120 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Boxed Processor Specifications 8.2.2 Boxed Processor Heat Sink Weight 8.2.2.1 Thermal Solution Weight The 1U passive/3U+ active combination heat sink solution and the 2U passive heat sink solution will not exceed a mass of 1050 grams. Note that this is per processor, a dual processor system will have up to 2100 grams total mass in the heat sinks. This large mass will require a minimum chassis stiffness to be met in order to withstand force during shock and vibration. See Section 3 for details on the processor weight. 8.2.3 Boxed Processor Retention Mechanism and Heat Sink Support (CEK) Baseboards and chassis designed for use by a system integrator should include holes that are in proper alignment with each other to support the boxed processor. Refer to the Server System Infrastructure Specification (SSI-EEB 3.6, TEB 2.1 or CEB 1.1). These specification can be found at: http://www.ssiforum.org. Figure 8-3 illustrates the Common Enabling Kit (CEK) retention solution. The CEK is designed to extend air-cooling capability through the use of larger heat sinks with minimal airflow blockage and bypass. CEK retention mechanisms can allow the use of much heavier heat sink masses compared to legacy limits by using a load path directly attached to the chassis pan. The CEK spring on the secondary side of the baseboard provides the necessary compressive load for the thermal interface material. The baseboard is intended to be isolated such that the dynamic loads from the heat sink are transferred to the chassis pan via the stiff screws and standoffs. The retention scheme reduces the risk of package pullout and solder joint failures. All components of the CEK heat sink solution will be captive to the heat sink and will only require a Phillips screwdriver to attach to the chassis pan. When installing the CEK, the CEK screws should be tightened until they will no longer turn easily. This should represent approximately 6-8 inch-pounds of torque. More than that may damage the retention mechanism components. 8.3 Electrical Requirements 8.3.1 Fan Power Supply (Active CEK) The 4-pin PWM controlled active thermal solution is being offered to help provide better control over pedestal chassis acoustics. This is achieved though more accurate measurement of processor die temperature through the processor’s Digital Thermal Sensors. Fan RPM is modulated through the use of an ASIC located on the baseboard, that sends out a PWM control signal to the 4th pin of the connector labeled as Control. This thermal solution requires a constant +12 V supplied to pin 2 of the active thermal solution and does not support variable voltage control or 3-pin PWM control. See Table 8-2 for details on the 4-pin active heat sink solution connectors. If the 4-pin active fan heat sink solution is connected to an older 3-pin baseboard CPU fan header it will default back to a thermistor controlled mode, allowing compatibility with legacy 3-wire designs. When operating in thermistor controlled mode, fan RPM is automatically varied based on the TINLET temperature measured by a thermistor located at the fan inlet of the heat sink solution. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 121 Boxed Processor Specifications The fan power header on the baseboard must be positioned to allow the fan heat sink power cable to reach it. The fan power header identification and location must be documented in the suppliers platform documentation, or on the baseboard itself. The baseboard fan power header should be positioned within 177.8 mm [7 in.] from the center of the processor socket. Table 8-1. Table 8-2. PWM Fan Frequency Specifications for 4-Pin Active CEK Thermal Solution Description Min Frequency Nominal Frequency Max Frequency Unit PWM Control Frequency Range 21,000 25,000 28,000 Hz Fan Specifications for 4-Pin Active CEK Thermal Solution Min Typ Steady +12 V: 12 volt fan power supply 10.8 IC: Fan Current Draw N/A 2 Description1 SENSE: SENSE frequency Max Steady Max Startup 12 12 13.2 V 1 1.25 1.5 A 2 2 2 Pulses per fan revolution Unit Note: 1. System board should pull this pin up to Vcc with a resistor Figure 8-11. Fan Cable Connector Pin Out for 4-Pin Active CEK Thermal Solution Table 8-3. Fan Cable Connector Pin Out for 4-Pin Active CEK Thermal Solution Note: 8.3.2 Pin Number Signal Color 1 Ground Black 2 Power: (+12 V) Yellow 3 Sense: 2 pulses per revolution Green 4 Control: 21 KHz-28 KHz Blue System board should provide an open drain / open collector for pin 4. Fan will pull this pin up to a specific voltage (5.25V max). Boxed Processor Cooling Requirements As previously stated the boxed processor will be available in two product configurations. Each configuration will require unique design considerations. Meeting the processor’s temperature specifications is also the function of the thermal design of the entire system, and ultimately the responsibility of the system integrator. The processor temperature specifications are found in Section 6 of this document. 122 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Boxed Processor Specifications 8.3.2.1 1U Passive/3U+ Active Combination Heat Sink Solution (1U Rack Passive) In the 1U configuration it is assumed that a chassis duct will be implemented to provide a minimum airflow of 15 cfm at 0.38 in. H2O (25.5 m3/hr at 94.6 Pa) of flow impedance. The duct should be carefully designed to minimize the airflow bypass around the heatsink. It is assumed that a 40°C TLA is met. This requires a superior chassis design to limit the TRISE at or below 5°C with an external ambient temperature of 35° C. Following these guidelines will allow the designer to meet Quad-Core Intel® Xeon® Processor X5300 Series Thermal Profile and conform to the thermal requirements of the processor. 8.3.2.2 1U Passive/3U+ Active Combination Heat Sink Solution (Pedestal Active) The active configuration of the combination solution is designed to help pedestal chassis users to meet the thermal processor requirements without the use of chassis ducting. It may be still be necessary to implement some form of chassis air guide or air duct to meet the TLA temperature of 40° C depending on the pedestal chassis layout. Also, while the active thermal solution design will mechanically fit into a 2U volumetric, it may not provide adequate airflow. This is due to the requirement of additional space at the top of the thermal solution to allow sufficient airflow into the heat sink fan. Use of the active configuration in a 2U rackmount chassis is not recommended. It is recommended that the ambient air temperature outside of the chassis be kept at or below 35°C. The air passing directly over the processor thermal solution should not be preheated by other system components. Meeting the processor’s temperature specification is the responsibility of the system integrator. 8.3.2.3 2U Passive Heat Sink Solution (2U+ Rack or Pedestal) In the 2U+ passive configuration it is assumed that a chassis duct will be implemented to provide a minimum airflow of 27 cfm at 0.182 in. H2O (45.9 m3/hr at 45.3 Pa) of flow impedance. The duct should be carefully designed to minimize the airflow bypass around the heatsink. The TLA temperature of 40° C should be met. This may require the use of superior design techniques to keep TRISE at or below 5°C based on an ambient external temperature of 35°C. 8.4 Boxed Processor Contents A direct chassis attach method must be used to avoid problems related to shock and vibration, due to the weight of the thermal solution required to cool the processor. The board must not bend beyond specification in order to avoid damage. The boxed processor contains the components necessary to solve both issues. The boxed processor will include the following items: • Quad-Core Intel® Xeon® Processor 5300 Series • Unattached heat sink solution • Four screws, four springs, and four heat sink standoffs (all captive to the heat sink) • Foam air bypass pad and skirt (included with 1U passive/3U+ active solution) • Thermal interface material (pre-applied on heat sink) • Installation and warranty manual • Intel Inside Logo Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 123 Boxed Processor Specifications The other items listed in Figure 8-3 that are required to compete this solution will be shipped with either the chassis or boards. They are as follows: • CEK Spring (supplied by baseboard vendors) • Heat sink standoffs (supplied by chassis vendors) § 124 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet Debug Tools Specifications 9 Debug Tools Specifications Please refer to the Debug Port Design Guide for UP/DP Systems and the appropriate platform design guidelines for information regarding debug tool specifications. Section 1.3 provides collateral details. 9.1 Debug Port System Requirements The Quad-Core Intel® Xeon® Processor 5300 Series debug port is the command and control interface for the In-Target Probe (ITP) debugger. The ITP enables run-time control of the processors for system debug. The debug port, which is connected to the FSB, is a combination of the system, JTAG and execution signals. There are several mechanical, electrical and functional constraints on the debug port that must be followed. The mechanical constraint requires the debug port connector to be installed in the system with adequate physical clearance. Electrical constraints exist due to the mixed high and low speed signals of the debug port for the processor. While the JTAG signals operate at a maximum of 75 MHz, the execution signals operate at the common clock FSB frequency. The functional constraint requires the debug port to use the JTAG system via a handshake and multiplexing scheme. In general, the information in this chapter may be used as a basis for including all runcontrol tools in Quad-Core Intel® Xeon® Processor 5300 Series based systems designs including tools from vendors other than Intel. Note: The debug port and JTAG signal chain must be designed into the processor board to utilize the XDP for debug purposes except for interposer solutions. 9.2 Target System Implementation 9.2.1 System Implementation Specific connectivity and layout guidelines for the Debug Port are provided in the Debug Port Design Guide for UP/DP Systems and the appropriate platform design guidelines. 9.3 Logic Analyzer Interface (LAI) Intel is working with two logic analyzer vendors to provide logic analyzer interfaces (LAIs) for use in debugging Quad-Core Intel® Xeon® Processor 5300 Series systems. Tektronix and Agilent should be contacted to obtain specific information about their logic analyzer interfaces. The following information is general in nature. Specific information must be obtained from the logic analyzer vendor. Due to the complexity of Quad-Core Intel® Xeon® Processor 5300 Series based multiprocessor systems, the LAI is critical in providing the ability to probe and capture FSB signals. There are two sets of considerations to keep in mind when designing a Quad-Core Intel® Xeon® Processor 5300 Series based system that can make use of an LAI: mechanical and electrical. Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 125 Debug Tools Specifications 9.3.1 Mechanical Considerations The LAI is installed between the processor socket and the processor. The LAI plugs into the socket, while the processor plugs into a socket on the LAI. Cabling that is part of the LAI egresses the system to allow an electrical connection between the processor and a logic analyzer. The maximum volume occupied by the LAI, known as the keepout volume, as well as the cable egress restrictions, should be obtained from the logic analyzer vendor. System designers must make sure that the keepout volume remains unobstructed inside the system. In some cases, it is known that some of the electrolytic capacitors fall inside of the keepout volume for the LAI. In this case, it is necessary to move these capacitors to the backside of the board before using the LAI. Additionally, note that it is possible that the keepout volume reserved for the LAI may include different requirements from the space normally occupied by the heatsink. If this is the case, the logic analyzer vendor will provide either a cooling solution as part of the LAI or additional hardware to mount the existing cooling solution. 9.3.2 Electrical Considerations The LAI will also affect the electrical performance of the FSB, therefore it is critical to obtain electrical load models from each of the logic analyzer vendors to be able to run system level simulations to prove that their tool will work in the system. Contact the logic analyzer vendor for electrical specifications and load models for the LAI solution they provide. § 126 Quad-Core Intel® Xeon® Processor 5300 Series Datasheet
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement