MONTECITO™ INSTALLATION AND OPERATION INSTRUCTIONS

Add to my manuals
24 Pages

advertisement

MONTECITO™ INSTALLATION AND OPERATION INSTRUCTIONS | Manualzz

05

/10

/20

13

INSTALLATION AND

OPERATION INSTRUCTIONS

MONTECITO™

SAVE THESE INSTRUCTIONS

FOR FUTURE REFERENCE

A French manual is available upon request. Order P/N 850037CF.

Ce manuel d’installation est disponible en francais, simplement en faire la demande. Numéro de la pièce 850037CF.

Fireplace, also for use in mobile or manufactured homes with solid fuel only.

WARNING

• Hot! Do not touch! The glass and surfaces of this appliance will be hot during operation and will retain heat for a while after shutting off the appliance. Severe burns may result.

• Carefully supervise children in the same room as appliance.

• If small children are present in the home, it is recommended that this appliance be fitted with an adjustable safety gate or barrier screen.

EPA Wood-Burning Fireplace

P/N 850037M REV. M 05/2013

MODEL

MONTE

This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and understand these instructions before beginning your installation.

Do not alter or modify the fireplace or its components under any circumstances. Any modification or alteration of the fireplace system, including but not limited to the fireplace, chimney components and accessories, may void the warranty, listings and approvals of this system and could result in an unsafe and potentially dangerous installation.

IHP wood-burning fireplaces are designed for use as a supplemental heater. They are not intended for continuous use as a primary heat source.

WARNING

• The fireplace cannot be operated without a door or firescreen. Consult your dealer to select the correct replacement door or firescreen.

• The fireplace is equipped with a blower, electrical connection must be made prior to fireplace installation

• Important! To assure proper alignment of glass doors: Install this fireplace in a square and plumb condition, using shims as necessary at sides and/or bottom.

• Install the fireplace only as described in these instructions.

Listed to standards:

ULC-S610 and UL-127

Report No. 307-4084

EPA Cert. No. 537

PIMONTECITO REV. 12 05/2013

2

IMPORTANT! GENERAL SAFETY

PRECAUTIONS. READ AND

UNDERSTAND THESE SAFETY

RULES BEFORE YOUR FIRST FIRE.

WARNING

The Montecito™ fireplace must be installed with an outside air kit intake, which is included with the fireplace

WARNING

THE FIREPLACE MUST BE OPER-

ATED WITH THE DOORS FULLY

OPENED OR DOORS FULLY CLOSED.

IF THE DOORS ARE LEFT PARTLY

OPENED, GAS AND FLAME MAY BE

DRAWN OUT OF THE FIREPLACE

OPENING, CREATING RISKS OF

BOTH FIRE AND SMOKE. IF THE

UNIT IS OPERATED WITH THE

DOORS FULLY OPENED, THE FIRE

SCREEN MUST BE USED.

WARNING

NEVER use gasoline, gasolinetype lantern fuel, kerosene, charcoal lighter fluid, naphtha, engine oil or similar liquids to start or “freshen up” a fire in this fireplace. Keep any flammable liquids a safe distance from the fireplace at all times.

WARNING

THIS FIREPLACE HAS NOT BEEN

TESTED WITH AN UNVENTED

GAS OR A FIREPLACE INSERT.

TO REDUCE RIS K OF FIRE OR

INJURY, DO NOT INSTALL AN

UNVENTED GAS LOG SET OR

FIREPLACE INSERT OR OTHER

PRODUCTS NOT SPECIFIED FOR

USE WITH THIS FIREPLACE.

WARNING

Never leave your fireplace unattended while it is burning.

WARNING

To avoid the risk of damaging fireplace materials and increasing the risk of fire, do not use the fireplace to cook or warm food.

WARNING

Use care when selecting window treatments for windows located near the fireplace. Avoid using combustible flowing window treatments such as curtains on nearby windows that are of sufficient length to be blown in front of an open flame when the window is opened. Keep any combustible furniture, materials or decorative pillows at least 48" (1219 mm) from the front fireplace opening.

WARNING

Never modify or alter your fireplace system in any way. To do so may create a potential fire hazard and void the limited warranty

, listings and approvals of this system.

IMPORTANT

When burning wood, use SOLID

NATURAL DRY WELL-SEASONED

WOOD ONLY. Hardwoods are recommended (soft woods tend to burn very quickly).

• DO NOT burn treated wood, charcoal, coal, trash, cardboard, driftwood, woods dipped in tar,

Christmas tree greens, pitch, pine tar, creosote, chemical chimney cleaners, flame colorants, polystyrene packaging, wood products with synthetic binders (i.e. plywood). Plywood, lumber and other misc. materials can produce abnormally high temperatures, sputtering and smoking fires and may contain hazardous chemicals to treat insects and fungus.

• Burning unapproved fuels can produce excessive temperatures, beyond the design capabilities of the fireplace and may produce excess sparks or may contain hazardous chemicals. Burning unapproved fuels can result in a chimney fire, a house fire, personal injury, death or loss of property.

WARNING

Never leave children unattended when there is a fire burning in the fireplace.

WARNING

Always ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air.

IMPORTANT

WHEN INSTALLED IN A MOBILE OR

MANUFACTURED HOME:

• Mobile or manufactured home installations must be installed in accordance with the requirements of the Department of Housing and

Urban Development (HUD) “Mobile

Home Construction and Safety standards” for US or Canada Mortgage and Housing Corporation (CMHC) for Canada.

• The fireplace must be fastened to the floor by unfolding and screwing the small tabs on both sides at the bottom of the fireplace.

• It is necessary to have access openings, for inspection purpose only, into built-in enclosures surrounding the fireplace installation.

Such openings to require a household tool for access.

• The vapor barrier of the mobile home shall be as close as possible of the location where the chimney assembly penetrates the ceiling and roof structure with no interference to the required clearance to combustible material.

• When the mobile or manufactured home has a flat roof, the Attic Radiation Shield must be installed from below going through the roof (See

Figures 22b and 22d).

• Warning: Do not install in a sleeping room.

• Caution: The structural integrity of the manufactured home floor, wall, and ceiling/roof must be maintained.

WARNING

Neither the manufacturer nor the seller warrants “smoke free” operation nor are we responsible for inadequate system draft caused by mechanical systems, general construction conditions, inadequate chimney heights, adverse wind conditions and/or unusual environmental factors or conditions beyond our control.

CONGRATULATIONS!

When you purchased your new fireplace, you joined the ranks of thousands of individuals whose answer to their home heating needs reflects their concern for aesthetics, efficiency and our environment. We extend our continued support to help you achieve the maximum benefit and enjoyment available from your new fireplace.

Thank you for selecting a IHP fireplace as the answer to your home supplemental heating needs.

TABLE OF CONTENTS

Safety Rules and Specifications for

Mobile or Manufactured

Home Installation .........................Page 2

Introduction ......................................Page 3

Parts Required .................................Page 3

Optional Equipment ...........................Page 3

Operating The Montecito Fireplace ....Page 3

Fuel ...................................................Page 3

Starting And Maintaining A Fire ........Page 4

Combustion Control .........................Page 4

Refueling For Best Performance .......Page 4

Smoking – Causes And

Troubleshooting ..............................Page 4

Important Cautions ...........................Page 5

Maintaining Your Fireplace ................Page 5

Creosote ............................................Page 5

Chimney Maintenance .......................Page 5

Dealing With A Chimney Fire .............Page 5

Finish Door Casing Care ....................Page 5

Disposing of Ashes ...........................Page 6

Refractory Installation .......................Page 6

Door Installation ...............................Page 6

Door Adjustment ...............................Page 6

Facade Installation ............................Page 7

Hearth Extension Requirements ........Page 7

Cold Climate Installations ..................Page 7

Framing Dimensions .........................Page 8

Nailing Flanges ..................................Page 9

Facing And Mantel ............................Page 9

Fireplace Blower ................................Page 10

Hot Air Ducting Installation ..............Page 10

Gravity Kit .........................................Page 10

Outside Air Kit ..................................Page 11

Chimney System ...............................Page 12

Chimney Installation Notes ...............Page 12

Chimney Installation Instructions ......Page 13

Offset Chimney Installation ...............Page 14

Angled Wall Radiation Shield ............Page 16

Glass Care - Replacement .................Page 17

Glass Care - Cleaning ........................Page 17

Gasket Replacement ........................Page 17

Fireplace Installation ........................Page 17

Chimney Support Installation ............Page 18

Chimney Chase And

Multiple Terminations......................Page 18

Masonry Application Instructions .....Page 19

Installation Accessories ....................Page 20

Replacement Parts ............................Page 21

Specifications ....................................Page 21

Clearances to Combustibles ..............Page 21

Chimney Components Lists ..............Page 22

Product Reference Information .........Page 24

THE FIREPLACE

INTRODUCTION

The Montecito™ wood-burning fireplace is an energy efficient, heat circulating, closed combustion fireplace. You will receive a lifetime of comfort and enjoyment from your fireplace provided it is installed, maintained and operated properly.

Please read these instructions and retain this manual for future reference.

Before beginning the fireplace installation, consult the local authorities to obtain your building permit and check your local building codes. Install the fireplace only as described in these instructions and using only IHP components.

• This fireplace has been tested for CAN/ULC

S610-M87 and ANSI/UL 127 under report number 307-4084. It has also been tested for EPA 40 C.F.R Part 60, section 60.532(b).

Certificate number 537.

The Montecito fireplace is NOT intended for use with a gas log set. Do not use a fireplace insert or any other product with this fireplace unless it is specified by IHP for use with this appliance. Failure to follow these instructions will void the certification and the warranty of the fireplace and may result in an unsafe installation.

• These appliances are designed to provide supplemental heat to the immediate area only. Therefore, it is advisable to have an alternate heat source when installed in a dwelling.

PARTS REqUIRED

Fireplace Model MONTE

• 6” diameter chimney

*

- Model ASHT+,

S-2100+, HT6000+, HT6103+ or AC manufactured by Security Chimneys International™ only, including:

- Chimney lengths

- Elbows (where necessary)

- Associated components as per these

installation instructions

..

Decorative Door - Required

....

(Order Separately - See Page 20)

Front Facade kit - Required

...

(Order Separately - See Page 20)

UZY5 blower (included in the fireplace).

VRUW Blower Speed Control (included)

Outside air kit (Included w/Fireplace)

OPTIONAL EqUIPMENT

• Additional Equipment (optional)

- Forced Air Kit u

- AC Chimney Adaptor

*

(required if using AC Chimney)

- AC Chimney Outside Air Kit

- Gravity Venting System

- Rigid Firescreen u

stalled, this appliance no longer qualifies for EPA certification.

OPERATING THE FIREPLACE

Fuel

USE SOLID NATURAL WOOD FUEL ONLY. The

Montecito fireplace is designed to work best when fueled with dry seasoned natural wood only. Hardwoods are preferred to softwoods since the energy content of wood is relative to its density. Hardwoods will result in a longer burning fire and less frequent refueling. A moisture content of 15% to 20% (seasoned) is recommended. Wood that has been cut and split and let to dry under a cover for a period of one year will usually meet that criteria. The required drying time will vary depending on the climate. Wood that is packed tight together will take longer to dry. Seasoned wood is darker in color than wet wood and will have visible cracks in the grain on the ends. Excessively wet wood will be difficult to burn and will result in lower efficiency, increased creosoting and deposits on the glass and in the chimney. Excessively dry wood will burn well but will also have higher emissions and shorter burning time.

Do not burn scrap or garbage, treated wood or wood such as driftwood from the ocean which has been exposed to salt or other chemicals.

Salt or chemicals can corrode the firebox and chimney. Do not burn large amounts of paper, cardboard, Christmas tree branches or building construction materials. Intense firing with these materials may overheat the fireplace, causing damage to the unit, a fire or even possibly igniting a chimney fire if the chimney is creosoted.

Burning unapproved fuel, resulting in excessive pollutants being emitted, may be prohibited and subject to a fine or other penalty by the authority having jurisdiction in your area.

Processed firelogs can be used. Although, do not poke or stir the logs while they are burning.

Use only firelogs that have been evaluated for the application of fireplace and refer to firelog warnings and caution markings on packaging prior to use.

First Fires

Before using the fireplace make sure to remove the plastic wrapping and EPA label on plated door. Remove any glue residue left by the label using mild soap.

The first five or six fires should be small fires of short duration (about 30 to 60 minutes). This will help cure the refractory bricks. During the first few fires of this appliance there may be some odor and smoke due to the curing of the paint, dust accumulation and burning off of lubricants used in the manufacturing process.

It may set off a smoke alarm located in the same room. For this reason the room should be well ventilated for the first few fires.

3

*

Available from Security Chimneys™

4

WARNING

Be careful adding wood fuel to the fire or handling fireplace tools such as shovels, tongs or pokers.

WARNING

The bottom refractory can be cracked by excessive abuse such as tossing heavy logs onto the grate or gouging with fireplace tools. Exercise caution when adding wood to your fireplace.

Building a Fire

(starting and maintaining a fire)

To start a fire, place several crumpled up balls of newspaper in the firebox. Place small dry pieces of kindling on top of the paper, criss-crossing the kindling so that there are air spaces in between.

Keep the fuel far back enough so that air can get underneath. Open the air controls fully and light the newspaper. Once the newspaper and the kindling is well ignited, close the door.

Once the kindling fire is well established, cord wood can be added (see Primary Air Combus-

tion Control section for proper operation of the air controls).

The unit will burn best with 2-3 pieces of cord wood spaced 1 to 2 inches apart and allowing air to get under the fuel. Criss-crossing or arranging the fuel so that air can get underneath, will help the fire to get started easily. The unit should be operated with the air control fully open long enough to get the cord wood well ignited.

COMBUSTION CONTROLS

Primary Air and Air Boost Controls

There is no flue damper in the Montecito™ wood burning fireplace. As is common with air tight stoves, the combustion air control sets the flow of air entering the firebox. This allows for a more precise control of the fire. The combustion air control is located below the door on

Figure 1

Combustion Air Register

the left side. The main source of air (primary air) entering the firebox can be diminished by moving the air combustion control from left to right. The primary air is fully opened when the air control is completely moved to the left.

The air control device can also be used to add an extra boost of air especially during fire start up and reloading of the unit.

Pulling the air combustion control will induce an air boost at the base of the fire allowing an easier fire start up. When the fire is well established, the control can be pushed in to shut down the air boost allowing for a longer burn time. The combustion air control should be in the closed position (primary air and air boost) when the fireplace is not in use. This will minimize air leakage up the chimney. The combustion air control should be opened before opening the door to minimize the possibility of back draft coming into the room.

Accelerated Combustion

The maximum heat output for the Montecito fireplace is achieved by burning with the door closed and the combustion air opened and pulled out. By this method, the Montecito fireplace can produce up to 55,000 BTU of heat per hour. However, it will be necessary to reload with wood every one or two hours.

This is the least efficient method of burning the

Montecito fireplace.

Use caution when firing with the combustion air control wide open. Only burn cord wood in this manner. Small dry pieces of softwood and construction scraps will burn very intensely using this method and may damage the firebox.

Medium Combustion

This is the recommended mode of operating the Montecito fireplace and should be the one normally used since it will deposit the least amount of creosote on the glass and in the chimney. The combustion air control must be

3/4 closed and pushed in to close the air boost.

The precise setting will depend on many factors, including chimney length and the moisture content of the wood.

Open

Push to Close

Air Boost

Close

Pull to Open

Air Boost

For instance, a long chimney will necessitate closing the damper more. To obtain the proper combustion, close the damper completely, then open it about 1/4” to 1/2”. Three medium size pieces of wood should be burning on a bed of hot coals. The heat output will be approximately

30,000 BTU per hour and the loading time will be about every 3-4 hours. Softwoods may be burned using this method but the time will be substantially reduced.

Slow Combustion

When the air combustion control is completely closed, the fireplace is in a slow combustion phase.

If the hearth is hot enough, slow combustion will not extinguish the fire, but there will be a noticeable change in the flame pattern. The flames will be slow and may appear dirty if the wood is too wet (moisture content of 20% and more). Do not allow the wood to burn without flame, since this will produce excessive creosote in the unit.

Creosote may accumulate on the glass door.

This method of burning should be used only after operating the Montecito fireplace with the air control opened to produce a hot fire for about an hour or at medium pace for at least three (3) hours. Slow combustion can be used at night in order to reduce the heat output and to prolong the burn. The loading time will be between 6-8 hours.

REFUELING FOR BEST PERFORMANCE

The Montecito fireplace will operate best if attention is given to operating the unit with the damper fully opened after refueling in order to bring the firebox and the chimney system up to their optimum operating temperature.

Combustion efficiency is relative to firebox temperature. A temperature of 500º C (932º F) and up, with a visible flame, in the upper part of the firebox indicates a maximum efficiency.

To obtain this temperature, the fireplace must be operated with the primary air and air boost controls fully opened during 10 to 20 minutes after reloading, depending on the heat and on the moisture content of the wood.

Once you have reached the desired temperature, the air boost can be closed and the primary air set to a medium setting. You know you have reached the desired temperature when, closing the primary air control, you can see a flame at the top of the firebox. The benefit of this technique will be cleaner glass, less creosoting, greater efficiency and the most pleasing fire for your enjoyment.

SMOKING –

CAUSES AND TROUBLESHOOTING

To reduce the likelihood of smoking when opening the door, set the combustion air controls to the left before opening the door. Your fireplace has been designed and tested to provide smoke free operation. Occasionally, there may be a small amount of smoking upon lighting the fire, until the chimney heats up but this should not continue. If the fireplace continues to smoke it is probably for one of the following reasons:

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

A. Negative pressure in the house - As the fire burns, air goes up the chimney. This air must be replaced through leakage into the house or through the outside air duct. When operating the Montecito fireplace, open a nearby window temporarily to check if there is adequate replacement air supply.

B. Fans operating (e.g.: range hood) - These fans draw air out of the house and may actually cause a negative pressure in the house. Turn off all fans and open a nearby window to determine if this is the cause of the problem.

C. Wet wood - Wet or tarred wood will smoulder and smoke instead of burn properly. Your dealer can help you determine if you have properly seasoned wood for burning.

D. Dirty or blocked chimney - Check to make sure the chimney is clear and clean. If dirty call a certified chimney sweep or use a properly sized chimney brush to clean.

E. Chimney not long enough - The minimum chimney height is twelve (12) feet (3.7 m) not including the fireplace height. The chimney must extend at least three (3) feet

(915 mm) above its point of contact with the roof and at least two (2) feet (610 mm) higher than any roof or wall within ten (10) feet (3 m) of it. When installed with offsets, the minimum chimney height is fifteen (15) feet (4.6 m). Additional height will increase draft and will decrease the tendency to smoke.

F. Poor chimney draft - With no fire, there should be sufficient draft to exhaust cigarette smoke introduced under the baffle. Chimneys installed against an outside wall without protection may generate back draft problems which will cause start-up problems. To prevent this, open a nearby window, roll up a piece of paper and light it. Then, hold it in the upper part of the firebox to warm up the chimney. Wait until the draft is sufficient, then start the fire.

IMPORTANT CAUTIONS

A. Do not block the hot air vents to the fireplace as this will cause the fireplace to overheat.

B. Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or ‘freshen up’ a fire in this fireplace. Keep all such liquids well away from the fireplace while it is in use.

C. Do not burn coal. The sulphur in coal will corrode the firebox and chimney.

D. Keep combustible materials at least 48”

(1.2 m) away from the front of the fireplace opening.

E. Never leave children unattended when there is a fire burning in the fireplace.

F. Do not use the fireplace as an incinerator to burn paper, cardboard or construction material such as pressed wood, plywood or lumber. Use only untreated wood.

Wood protectors, metallic paper, coal, plastic, waste, beach wood, Christmas tree, sulphur and/or oil will damage the fireplace.

G. Do not burn driftwood which has been in the ocean or salt water. The salt will corrode the firebox and chimney.

H. Do not burn wood in the area in front of the grate.

I. Do not allow the wood to smoulder or burn without flame, since this will produce excessive creosote in the unit as well as increased particulate emissions.

J. Blower for forced air kit operating - Make sure that the blower is at the “off” position when you open the fireplace door for reloading.

MAINTAINING YOUR FIREPLACE

Creosote - Formation and Need for Removal

When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited this creosote makes an extremely hot fire.

The chimney shall be inspected at least twice a year during the heating season to determine when a creosote buildup has occurred.

When creosote has accumulated it shall be removed to reduce the risk of a chimney fire.

When the creosote accumulation is large, a creosote fire in the chimney can damage the chimney and overheat the surrounding wood framing. Creosote formation in a chimney can be minimized by making sure there is always visible flame burning, avoid smouldering fires and by proper refuelling techniques.

Chimney Maintenance

Regular chimney inspection and maintenance combined with proper operation will prevent chimney fires. Keep your chimney clean. Do not allow more than 1/16” (1.6 mm) creosote build up in your chimney. The amount of creosote will depend on variables such as frequency of use and type of fire. We recommend that you:

A. Initially inspect the chimney system weekly.

From this, you will learn how often it will be necessary to clean your chimney.

B. Have your chimney cleaned by a qualified chimney sweep. If you wish to clean it yourself, we recommend using a stiff plastic or non-metallic brush. If a metal brush is used, its size should be slightly smaller than the flue to avoid damaging the chimney. Do not use a brush that will scratch the stainless steel interior of the chimney.

C. Do not expect chemical cleaners to keep your chimney clean. The rain cap can be removed for inspection and/or cleaning of the chimney.

Caution: It is necessary to remove the baffle from the top of the firebox before cleaning the chimney. See “Top Baffle Removal Prior To

Chimney Sweep.”

Dealing With a Chimney Fire

Regular chimney maintenance and inspection can prevent chimney fires. If you have a chimney fire, follow these steps:

1. Close the fireplace door and the combustion air controls.

2. Alert your family of the possible danger.

3. If you require assistance, alert your fire department.

4. If possible, use a dry chemical fire extinguisher, baking soda or sand to control the fire. Do not use water as it may cause a dangerous steam explosion.

5. Check outside to ensure that sparks and hot embers coming out of the chimney are not igniting the roof.

6. Do not use the fireplace again until your chimney and fireplace have been inspected by a qualified chimney sweep or a Fire

Department Inspector.

Top Baffle Removal Prior to Cleaning The

Chimney

Before starting to clean your chimney, we recommend that you remove the top baffle to avoid creosote dust collection at the top of the baffle. Follow these steps to set the top baffle out of the way:

1. Remove the side refractory holder. They are located at the top of the refractory.

2. Lift the front baffle.

3. Slide the back baffle under the front baffle.

You now have access to the chimney.

Figure 2A - Top Baffle Removal

Figure 2B - Top Baffle Removal

Finish Door Casing Care

Use a glass cleaner and a soft cloth to polish the casing. Do not use abrasives such as steel wool, steel pads or an abrasive polish for they may scratch the casing’s finish.

5

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

DISPOSING OF ASHES

NOTE: For better performances, we recommend leaving 1/2 inch of ashes in the firebox.

Remove ashes only when the fire is out and the ashes are cold (24 to 48 hours after the fire is out).

Do not leave the ashes in the house as they give off carbon monoxide and other toxic gases.

WARNING

Disposal of Ashes: Ashes should be placed in a steel container with a tight fitting lid and moved outdoors immediately. The closed container of ashes should be placed on a non-combustible floor or on the ground well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled.

REFRACTORY REPLACEMENT

The intense heat of the fire will normally cause hairline cracks in the refractory. These cracks can be minimized by proper curing as described in “First Fires”. They will not normally diminish the effectiveness of the refractory. If large cracks develop, then the refractory should be replaced. To replace the refractory bricks, follow these steps:

1. Remove the front refractories

2. Remove the bottom refractory

3. Remove the left side refractory

4. Remove the right side refractory

5. Remove the back refractory

6. Remove the front ceramic baffle

7. Remove the rear ceramic baffle

To install the new refractories, follow the above steps in reverse.

1. Front Refractories

2. Bottom Refractory

3. Left Side Refractory

4. Right Side Refractory

5. Back Refractory

6. Front Ceramic Baffle

7. Rear Ceramic Baffle

Figure 3

5

3

DOOR INSTALLATION

The door must be installed only when the installation of the Montecito™ fireplace is completed.

All you have to do is fit the male part of the hinge, already on the door, to the female part, which is on the fireplace. To remove the door, simply pull the door up from the hinges (see Figure 4).

The door adjustment has been set at the factory. If the fit is still not perfect, you can adjust the door using the hinge screws.

DOOR ADJUSTMENT

The door may need to be adjusted to be completely airtight. The gaskets’ air-tightness can be adjusted using the adjustment screw located on the right side of the fireplace facade (An Allen key

#1/8 – not supplied - will be necessary for this adjustment).

Checking Door Seal

A one-inch strip of paper may be used to perform a test of the integrity of the door seal. Close the door on the paper in at least eight points. It is normal to feel only a slight amount of friction.

The door gasket does not need to be “tight” in all areas, since a small amount of leakage is not hazardous or detrimental to the performance of your fireplace.

WARNING

2

7

1

6

4

• Use only a IHP glass doors, specifically designed for the Montecito fireplace.

The fireplace cannot be operated without door or firescreen. Consult your dealer to select the correct replacement door or firescreen.

• Important! To assure proper alignment of glass doors: Install this fireplace in a square and plumb condition, using shims as necessary at sides and/or bottom.

Hinges Adjustment

Gasket Adjustment Screw

6

Figure 4

Door Installation

Figure 5

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Facade Installation

Install the Facade per instructions provided in

Facade Kit (ordered separately - see Page 20).

Framing, Facing And Mantel

The construction of the framing, facing, and mantel must be in accordance with the standards and the following illustrations (Figures

10 and 11):

A. Frame the fireplace using 2” x 3” or heavier lumber.

B. WARNING: Combustible materials cannot be used in the space directly above the fireplace, except for the studs above the facade that support the facing and mantel. This area must remain empty for a height of 6’8” (2,032 mm) measured from the base of the appliance.

C. Frame the fireplace with vertical studs at the sides of the fireplace running from floor to ceiling (see Figure 8). If combustible facing is to be used, position the studs back, from the front edge of the fireplace (a space that is the thickness of the facing material, so that the facing can be installed flush with the fireplace facing). Frame headers between the vertical studs only as follows:

• Place 2” x 3” or 2” x 4” headers, only along the upper part of the front, side and back faces (some codes may require a 2” x 6” on an outside bearing wall). Do not put wood or any combustible material within the area above the fireplace except on the front facing.

• Place headers only as required to support the facing and mantel.

D. WARNING: The fireplace must not be in contact with any insulation or loose filling material. Cover the insulation with drywall panels around the fireplace.

Hearth Extension Requirements

The Montecito

TM

fireplace may be installed directly on a combustible floor. The supplied safety metal strip must be positioned as follows:

One half under the front of the fireplace and the other half must extend on the floor over which the hearth extension will be built (see Figure 7A).

* The safety metal strip must cover the entire width of the fireplace.

The combustible floor in front of the fireplace must be covered with a non-combustible material (tile, marble, stone, etc). See Figures 7B.

COLD CLIMATE INSTALLATIONS

Climates where temperatures will fall below

32° F (0° C).

The heating performance of the appliance will vary depending upon the level of insulation, house design, how the appliance is operated, etc.

If this fireplace is being installed in a cold climate, it is especially important to seal all cracks around the fireplace and wherever cold air could enter the room with noncombustible material.

The crack between the fireplace and the hearth extension must be sealed with a non-combustible material such as sand-cement grout.

Elevated Fireplaces

u

Elevated fireplace installations require a special “Z” Metal Safety Strips

(field provided), in place of the safety metal strip shown above. The safety strip should extend the full width of the fireplace. When more than one safety strip is used they must overlap by a minimum of 1”. Hearth extension of an elevated fireplace must respect the same minimal dimensions as a fireplace installed directly on the floor

(Figure 7B).

Floor

Figure 7A - Hearth Extension Requirements

Figure 7B

Fireplace

42”

(1067mm)

Min.

18”

(457mm)

Mantel

WARNING: THE HEARTH EXTEN-

SION IS TO BE INSTALLED ONLY

AS ILLUSTRATED.

Safety Metal Strip

Hearth Extension

Non-Combustible

Finish Material

12” Max.

(305mm)

Platform

2”

u

1/2”

13mm

Fireplace

Area where wood

Mantel can be installed

Hearth

Extension

36”

(914mm)

45 Deg.

17” Min.

(432mm)

Non-Combustible Material

Also, the outside air inlet duct should be wrapped with noncombustible insulation to minimize the formation of condensation. Do not place insulation materials directly against the chimney sections. We recommend that you use the insulated wall radiation shield since it will maintain the home’s thermal barrier. AC chimney is NOT recommended in very cold climates (in areas with temperatures below 32°F (0°C).

7

NOTE: DIAGRAMS and ILLUSTRATIONS ARE NOT TO SCALE.

8

FRAMING DIMENSIONS

Fireplace Opening Width

A 36-1/4” 921 mm

B 42” 1067 mm

C 30-1/16” 764 mm

D

E

13-1/2” 343 mm

77” 1956 mm

F 37-1/2” 953 mm

G *24-1/2” 603 mm

J 53-3/4” 1365 mm

K

L

8”

1”

203 mm

25 mm

Back Wall of Chase/Enclosure

Including Finising Materials if any

C

OUTSIDE CHASE

* Zero Clearance

From Back

Spacer to Wall

* Total depth is 25 inches (635mm) including the back spacer minus 1/2 inch (13mm) for drywall to be flush with the facing.

Combustion Air Kit

G

A

Rough Framing Face (Unfinished Shown)

Combustible materials can NOT be used in the space directly above the fireplace. Do not fill the space above the fireplace with any material (Except the wood framing)

2” x 3”

Min.

Plywood 1/2”

F

Corner Installation

20-1/2”

D

19-19/32”

E

G

B

7’

Min.

B

A

Fireplace Framing

K

Rough Framing Face

(dimension includes finish material inside framing, if any)

Facing

Notes

Diagrams, illustrations and photographs are not to scale – consult installation instructions. Product designs, materials, dimensions, specifications, colors and prices are subject to change or discontinuance without notice.

All framing dimensions calculated for

1/2" dry wall at the fireplace face. If sheathing the chase or finishing with other thickness materials, calculations will need to be made.

* The fireplace must not be in contact with any insulation or loose filling material. Cover the insulation with Drywall panels around the fireplace.

22-19/32”

42”

28-1/32”

9-3/4”

1”

10-3/8”

13-15/16”

24”

J

Header

IMPORTANT

The facade must be removable once installed. The facade is designed to overlap any facing material installed on the front of the fireplace. If thicker material is installed, use the facade as a template and make sure it can be easily removed for servicing.

1. Combustible material must be installed flush with the fireplace. It may not project in front of and on the fireplace (i.e. the steel facade of the fireplace) (Figure 12).

2. Non-combustible materials such as brick, stone or ceramic tile may project in front of and onto the fireplace facing (Figure 13).

12-1/4”

36-1/16”

17-3/4”

17-3/4”

3-1/4”

6-3/4

8-1/4”

24”

Figure 8 - Framing Dimensions

22-1/2”

36”

12-3/4

15-1/2”

3-3/4

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Insulate Joists

Same As Ceiling

INSULATED CHASE CONSTRUCTION

Roof Support

Attic Radiation

Shield

NOTE: It is recommended that the chase walls and floor be insulated in the same manner, using the same insulation, as the rest of the building, below the attic.

Firestop

Storm Collar

Flashing

Draft Stops

Floor

Ceiling

Wall

Firestop

CTDT

Termination

• Must have the same firestopping resistance as adjacent wall.

• Must have the same insulation as adjacent ceiling.

• Follow local rules regarding framing construction.

Chase

Flashing

Must Be

Used To

Cover

Chase

Opening

7’

(2.1 m)

Min.

6’ 8”

(2 m)

Min.

Optional

Insulation

SEE NOTE

Chase

Figure 9

1/2” Plywood

Drywall or Any Rigid

Material

2” x 4”

Insulation

(Thermal Barrier)

8’

(2.4 m)

Level

Nailing Flanges

Four nailing flanges are provided to secure the fireplace to the floor (see figure below). Bend the nailing flanges down so that each flange is flush with the floor, then using nails or screws, secure the fireplace to the floor (2 places each side). The heads of the screws or nails must be large enough to completely cover the holes in the nailing flanges.

1

Fireplace Frame Section

(Top View)

3

4

5

2

6

Fireplace Side

Nailing Flange

(2 places each side)

Unbend to floor and nail/screw

Mantel and Facing

The mantel must be installed at least 42”

(1067 mm) above the base of the fireplace

(Figure 11).

3

1

7

2

1. Fireplace

2. Front of fireplace

3. Wood frame (2” x 3” min)

4. Drywall

5. Tiles

6. Rock board or other

7. Brick

Figure 10

4

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Solid

Continuous

Surface

Outside

Base

Mantel

Mantel and Facing

(Side View)

Drywall

2” X 3” Min.

(51mm x 76mm)

Spacer

42” (1067mm)

Rock Board or Other

Noncombustible

Facing

Drywall

Figure 11

Rock Board or Other

Noncombustible

Facing

.. ...

.. ...

.. ...

.. ...

.. ...

.. ...

.. ...

.. ...

.. ...

.. ...

.. ...

.. ...

.. ...

.. ...

.. ...

.. ...

.. ...

.. ...

.. ...

.. ...

.. ...

.. ...

.. ...

...

.. ...

.. ...

9

Only non-combustible material should be superposed or projecting over the front of the fireplace.

Figure 12

Noncombustible Facing

Drywall

2” X 3” Min.

Rock Board or Other

Spacer

42”

(1067mm)

Min.

HOT AIR DUCTING INSTALLATION

The Montecito™ wood burning fireplace is approved for use with a Gravity kit (hot air ducting system).

Gravity Kit

The gravity kit is designed for double hot air outlets and includes: (See Figure 14).

- Two (2) telescopic lengths 8” I.D.

- Two (2) 90º elbows 8” I.D.

- Two (2) hot air outlet kits

(grill and frames)

- Two (2) adaptors

See Gravity Kit Accessories Page 20.

For safe installation, the gravity kit must meet the following requirements:

Minimum height* 68” (1,727 mm)

Maximum length See Figure 14

* The height of the louver must be measured from the base of the Montecito fireplace to the middle point of the louver.

The only blower that can be used with the gravity kit is the one sold with the fireplace.

To extend the double outlet system, it will be necessary to purchase two adjustable lengths

(H8951).

Grill

Frame

WARNING: Both pipes of the double hot air outlet must be installed. Any other installation may cause fire and void warranty.

Figure 15

When installing the double outlet system, the hot air outlets can be installed in the same room as the fireplace, or one or both of the outlets can be installed in adjacent or upper rooms.

Installing the ducts at different elevations will tend to exhaust more heat out of the higher outlet (Figure 14).

WARNING: The outlet grills should not be installed facing upward through a floor.

Danger of burns can result if grills in floor are stepped on.

10

Figure 13

FIREPLACE BLOWER

The fireplace comes equipped with a heat activated blower. It is located in the bottom of the fireplace, towards the back. It uses 120V and must be connected to the main electrical circuit by a qualified electrician. For connection, use the electrical box supplied with the unit located on the bottom right corner of the fireplace.

If you wish to adjust the blower speed, the variable speed control (VRUW) provided must be installed in line with the wiring. Again, use a qualified electrician for installation.

If the blower requires servicing,

1- Remove the doors and decorative facade.

2- Remove the screw located below the blower motor that holds it to the back of fireplace.

3- Pull the blower out of the unit through the square hole located in the front bottom right corner.

Outlet Grill

13” x 13”

(330mm x 330mm)

10’ (3.1m)

Max.

Maintain at least 6-1/2”

(160 mm) clearance from the outlet grill framing to a combustible ceiling, side wall or mantel.

Figure 14

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Outlet Grill

10’

(3.1m)

Max.

Figure 17

Flashing Collar

Flashing

Firestop

Rain Cap

Roof Support

Attic Radiation Shield

6-1/2” Min.

(165mm) to ceiling

68” Min.

(1727mm)

42” Min.

(1067mm)

Non-Combustible

Facing

The duct system must be installed respecting the following:

1. Remove the plates closing up the 8” dia. holes on top of the fireplace. Then, cut the insulation in order to obtain two 8” dia. openings.

Fix the adaptors on the fireplace openings by turning clockwise (Figure 15).

2. Maintain at least a 2” (50 mm) clearance between the ducts and any combustible material; the required hole size is 13” x 13”

(330 mm x 330 mm).

Exception #1: For the grills, the framing can be 10-3/4” x 10-3/4” (275 mm x 275 mm) to provide the clearance as required by the integral spacers on the double outlet duct system.

3. The maximum number of elbows in a run of duct is two.

4. Maintain at least 6-1/2” (160 mm) clearance from the outlet grill framing to a combustible ceiling, side wall or mantel.

5. When traversing a combustible wall or floor, a firestop must be installed at the wall or floor penetration. The hole size must be

13” x 13” (330 mm x 330 mm)

6. Do not connect the hot air ducts to a central heating system. Malfunction of the heating system’s blower will cause the fireplace to overheat. A furnace duct is only single wall and not double wall as is required for the

Montecito fireplace hot air exhaust.

7. Use only IHP grills and components as described in this manual. Other grills or registers, for example, may be too restrictive and may overheat the fireplace or ceiling.

8. Do not use insulated flexible ducts as they will overheat.

9. Do not use tees or any other components than the ones specifically listed here.

10. Never allow the ducting to pitch down as hot air will be trapped creating a fire hazard.

Never route the ducting downwards.

11. The hot air outlet grills must be installed with the louvers pointing downwards in order to prevent overheating adjacent ceilings.

12. Always install the two outlet grills when using the double hot air outlet kit.

OUTSIDE AIR KIT

It is mandatory to install an outside air connection to the Montecito™ wood burning fireplace.

The following components are required and are included with the fireplace:

• Outside air kit (includes 4 inch flex that goes up to ten (10) feet long)

• 4” Adaptor for fireplace connection

The outside air assembly must be installed according to the following requirements:

Outside Air Installation

The outside air assembly may be installed according to the following requirements:

A) Duct length should be kept to a minimum.

The maximum length of a 4” interior diameter

(100 mm) insulated flexible duct is twenty

(20) feet (6.1 m). (See note below).

B) The air intake register must not be installed more than ten (10) feet (3050 mm) above the base of the fireplace.

C) The fresh air must come from outside the house. The air intake must not draw air from the attic, basement or garage.

D) The air intake should be installed where it is not likely to be blocked by snow or exposed to extreme wind and away from automobile exhaust fumes, gas meters and other vents.

E) The duct and register may be installed above or below floor level.

Make a 4-1/4” (110 mm) hole in the outside wall of the house at the chosen location. From outside, place the outside air register in the hole

(open side down) and fasten the register to the wall with screws as shown (see Figure 18).

Slip the pipe into the insulated sleeve. Place the insulated pipe over the register tube and over the fireplace’s outside air connector (see

Figure 19). At each end, carefully pull back the insulation and plastic cover exposing the flexible pipe. Using the aluminium tape provided, wrap the tape around the joint between the flexible pipe and the air inlets. Carefully push the insulation and plastic cover back over the pipe. Using aluminium tape, fasten the plastic cover in place.

NOTE: We recommend not to exceed twenty

(20) feet of 4” flexible pipe. If you require a longer length we recommend that you use a 5” diameter flexible pipe for the complete run up to thirty (30) feet and a 6” diameter pipe for a run of up to forty (40) feet.

11

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

12

Outside

Intake

Screw

Opening

Facing

Down

Wall

Figure 18

Fireplace

Connection

Aluminum Tape

Plastic

Cover

OUTSIDE CONNECTION

Aluminum Tape

Plastic Cover

Insulation

Flexible Pipe

Aluminum Tape

5. All chimney installations must include at least one support. Reducing the amount of chimney weight on the fireplace will help avoid the noise created when the fireplace expands. This can be achieved by having the chimney supported by the supports. The maximum chimney length that can be supported by the fireplace is nine (9) feet (2.75 m) for S-2100+

*

/HT6000+

*

, twelve (12) feet (3.7 m) for

ASHT+

*

/ HT6103+

*

and 26 feet (8 m) for AC

*

chimney.

6. The chimney must extend at least three (3) feet (915 mm) above its point of contact with the roof and at least two (2) feet (610 mm) higher than any wall, roof or building within ten (10) feet (3m) of it (Figure 20).

7. If the chimney extends higher than five (5) feet (1,500 mm) above its point of contact with the roof, it must be secured using a roof brace.

8. A rain cap must be installed on top of the chimney. Failure to install a rain cap may cause corrosion problems.

9. Cut and frame square holes in all floors, ceilings, and roof that the chimney will go through to provide a 2” (50 mm) clearance between the chimney and any combustible materials. Do not fill this 2” space with insulation or any other combustible material.

10. Portions of the chimney which may extend through accessible spaces must be enclosed to avoid contact with combustible materials or damage to the chimney.

11. When offsets are used, the pipe may not penetrate a ceiling or floor unless it is running vertical (no 30° offsets).

Fireplace two (2) feet Min.

ten (10) feet three (3) feet Min.

Insulation

Flexible Pipe

Figure 19

Aluminum Tape

THE CHIMNEY SYSTEM

Chimney Installation Notes

1. If possible, install an interior chimney as it will provide better performance. In areas with continuous temperatures below -18° C (0° F), the use of an exterior chimney increases the likelihood of operating problems such as low draft, high rate of creosoting, and poor start-up characteristics. Exterior chimneys are also prone to down-with dry and flow reversal. Installations, which are located on lower floors in the house, such as in a basement, in combination with outside chimney, are especially prone to flow reversal.

2. The IHP fireplace model Montecito may be installed only with Security

Chimneys International 6” diameter chimney systems.

3. A chimney venting a fireplace shall not vent any other appliance.

4. The minimum chimney height is twelve (12) feet (3.7 m). In altitude, add 18” (450 mm) to the chimney for every 2,000 feet (600 m) above sea level.

Figure 20

NOTE: 2" clearance to combustibles around chimney components required.

NOTE: Blown or fill type insulation materials must not be in contact with the fireplace or in the enclosure frame as described in ‘’Enclosure’’ section.

NOTE: Local codes may not require firestopping at the ceiling levels for outside chase installations. However, it is recommended for safety and the reduction of heat loss.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

*

Available from Security Chimneys™

CHIMNEY INSTALLATION

INSTRUCTIONS

1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass (see

Figure 21). Use a plumb-bob to line up the center of the holes. The sizes are indicated in Table 2 for the floor and ceiling holes and Table 3 (Page 15) for the roof holes.

CHIMNEY MODEL

ASHT+ / HT6103+ *

S-2100+ / HT6000+*

AC *

SqUARE HOLE

SIZE OPENING

12-3/8” (314 mm)

14-1/8” (359 mm)

15 in (380 mm)

NOTE: See Table 3 for Sloped Roof Framing

Table 2 - Flat Roof Framing

ASHT / S2100

HT6103+ / HT6000+

Solid Packed Pipe *

Figure 22a

AC

Air Cooled Pipe *

Attic Radiation Shield

Firestop

Attic Radiation

Shield

Flashing

Attic Radiation

Shield

Roof

Mobile / Manufactured Home with Flat Roof

ASHT / S2100

Figure 22b

HT6103+ / HT6000+ *

Attic Radiation

Shield

Flashing

Figure 21 - Roof Framing

2. From below, install a firestop in each ceiling/ floor separation through which the chimney will pass. At the attic level, install an attic radiation shield from above (Figures 22a

and 22b).

3. For ASHT+

*

/ HT6103+

*

and S2100+

*

/

HT6000+

*

chimneys place the first chimney length on the fireplace. To lock it in place, turn 1/4 of a turn clockwise. With the AC

*

chimney, you must use a starter section before installing the first chimney length

(Figure 23). Continue installing chimney lengths making sure to lock each length in place.

4. Every time the chimney passes through a ceiling or a wall, install the appropriate firestop. When you reach the desired height, install the roof support. When installing a support, slightly lift the chimney system so the weight will lie on the support, not on the fireplace to reduce expansion noises (refer to instructions included with the support).

5. Then, put the roof flashing in place and seal the joint between the roof and the flashing with roofing pitch (see Figures 24 and 25).

For sloping roofs, place the flashing under the upper shingles and on top of the lower shingles. Nail the flashing to the roof, using roofing nails.

6. Place the spacers and the storm collar over the flashing, and tighten it with the bolt supplied. Finally, seal the joint between the storm collar and the chimney, using silicone caulking.

7. Install the chimney cap. Once the chimney cap is in place, the roof flashing can be washed with a solvent or vinegar and then painted with rust-proof paint.

Figure 22c

AC

*

CHIMNEY INSTALLATION

(AIR COOLED GALVANIZED CHIMNEY)

Collar

Flashing

Chimney Outside

Air Intake

(required when using AC chimney)

Outside Combustion

Air Kit

Radiation Shield

u

Mobile / Manufactured Home with Flat Roof

Figure 22d

AC* Chimney

Rain Cap

Attic Radiation

Shield

Firestop

Universal Support

AC Starter Section

Figure 23

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

u

Combustibles are not allowed below top spacers above the fireplace. Facing in front of fireplace must be non-combustible below this area.

*

Available from Security Chimneys™

13

Collar

Figure 24

AC *

Air Cooled Chimney

Chimney

Spacer (built into flashing)

Flashing

Figure 25

SLOPE

Roof Pitch

0 *

2/12

4/12

6/12

8/12

10/12

Roof Down Slope Hole Size

ASHT+* / HT6103+*

6”

12-3/8” (314 mm)

12-9/16” (319 mm)

13” (330 mm)

13-7/8” (352 mm)

14-7/8” (378 mm)

16-1/8” (410 mm)

S-2100+* / HT6000+*

6”

14-1/8” (359 mm)

14-3/8” (365 mm)

14-7/8” (378 mm)

15-3/4” (400 mm)

17” (432 mm)

18-3/8” (467 mm)

12/12 17-1/2” (445 mm) 20” (508 mm)

* Cross Slope Hole Size

Put the chimney cap into place.

Wash the roof flashing with a solvent or vinegar, then paint it with rust-proof paint.

Table 3

AC*

6”

15” (380 mm)

15 3/8” (390 mm)

16 1/8” (410 mm)

16 7/8” (430 mm)

18 1/4” (465 mm)

19 5/8” (500 mm)

21 3/8” (545 mm)

OFFSET CHIMNEY INSTALLATION

After reaching the location requiring the elbow, proceed as follows. The minimum chimney height when using elbows is:

Four (4) elbows

Table 4

Minimum Chimney Height Using Elbows

Fireplace Model MONTE

Chimney Model

*

Vertical installation

Two (2) elbows

ASHT+ / S2100+ / HT6103+ / HT6000+ / AC

12 feet (3.66 m)

15 feet (4.57 m)

17 feet (5.18 m)

Figure 31

NOTES:

Must return to vertical before penetrating ceiling or floor.

A maximum of 2 offsets are allowed.

After reaching the location requiring the elbow, proceed as follows:

ASHT+ / HT6103+ / S-2100+ / HT6000+

Chimneys

*

1. Install the first elbow; turn it in the required direction. Fasten it to the chimney with the three (3) 1/2” (12 mm) metal screws provided with the elbow.

2. Install the necessary chimney lengths to achieve the required offset. Lock the chimney lengths together: it is recommended to use three (3) 1/2” (12 mm) screws. If the offset length is made of two (2) chimney lengths or more, use an offset or roof support halfway up the offset. If penetrating a wall, install a wall radiation shield (see Figures 27 and

29).

3. Use another elbow to turn the chimney vertically. Secure the elbow, using three

(3) 1/2” (12 mm) screws (provided with the elbow).

4. Use a plumb-bob to line up the center of the hole. Cut a hole for the chimney in the ceiling/floor. Frame this hole as described previously (refer to section Chimney Instal-

lation Instructions).

5. From below, install a firestop (See Figure

22a).

6. A support (ST

*

or SO

*

) must be used on the first 15’ section (5 m).

7. Continue with the regular installation.

AC Chimney

*

1. Install the first elbow. Turn it in the required direction. To lock it in place, turn 1/8 of a turn. Fasten the straps attached to the elbow to the surrounding frame, using nails or drywall screws (see Figure 27).

2. Install the necessary chimney lengths to achieve the required offset. Lock the chimney lengths together. If penetrating a wall, use a wall radiation shield.

3. Use another elbow to turn the chimney vertically. Lock it to the chimney. Fasten the straps attached to the elbow to the surrounding framing using nails or drywall screws.

4. Use a plumb-bob to line up the center of the hole. Cut a hole for the chimney in the ceiling.

Frame this hole as described previously.

5. From below, install a firestop (see Figure

22c).

6. Continue with the regular installation.

NOTE: When using AC

*

chimney, an AC6SB

*

(H3779

*

) starter section must be used before installing an elbow. When an offset is needed immediately off the top of the fireplace, an elbow starter section, AC6SB30

*

(H3780

*

), is available.

14

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

*

Available from Security Chimneys™

Offset Dimensions

B

Total Height

A

Horizontal Offset

Chimney

6” *

Secure

Temp ®

ASHT

Nova Temp

®

HT6103+

Elbow Offset &

Height

15º

8”

A

3-5/16”

(84mm)

30º

B

15-11/16”

(398mm)

A

7-7/16”

(189mm)

45º

B

20”

(508mm)

A

10-5/16”

(262mm)

B

17-13/16”

(452mm)

12”

4-5/16”

(110mm)

One Length Between Elbows

18” 24” 36”

5-7/8”

(149mm)

7-7/16”

(189mm)

10-1/2”

(267mm)

19-9/16”

(497mm)

9-7/16”

(240mm)

25-3/8”

(645mm)

12-7/16”

(316mm)

31-3/16”

(792mm)

15-7/16”

(392mm)

42-3/4”

(1086mm)

21-7/16”

(545mm)

23-1/2”

(597mm)

13-3/16”

(335mm)

20-5/8”

(524mm)

28-11/16”

(729mm)

17-3/8”

(441mm)

24-7/8”

(632mm)

33-7/8”

(860mm)

21-5/8”

(549mm)

29-1/8”

(740mm)

44-1/4”

(1124mm)

30-1/8”

(765mm)

37-5/8”

(956mm)

48”

13-5/8”

(346mm)

54-3/8”

(1381mm)

27-7/16”

(697mm)

54-11/16”

(1389mm)

38-5/8”

(981mm)

46-1/8”

(1172mm)

Two Lengths Between Elbows

8” & 48” 12” & 48” 18” & 48” 24” & 48” 36” & 48” 48” & 48”

15-3/8”

(391mm)

60-15/16”

(1548mm)

16-7/16”

(418mm)

64-13/16”

(1646mm)

18”

(457mm)

70-9/16”

(1792mm)

19-1/2”

(495mm)

76-3/8”

(1940mm)

22-5/8”

(575mm)

87”

(2210mm)

25-3/4”

(654mm)

99-9/16”

(2529mm)

30-13/16”

(783mm)

60-9/16”

(1538mm)

43-7/16”

(113mm)

50-15/16”

(1294mm)

32-13/16”

(833mm)

64“

(1627mm)

46-1/4”

(1175mm)

53-3/4”

(1365mm)

35-13/16”

(910mm)

69-1/4”

(1759mm)

50-1/2”

(1283mm)

58”

(1473mm)

38-13/16”

(986mm)

74-7/16”

(1891mm)

54-3/4”

(1391mm)

62-1/4”

(1581mm)

44-13/16”

(1138mm)

84-13/16”

(2154mm)

63-1/4”

(1607mm)

70-3/4”

(1797mm)

50-13/16”

(1291mm)

95-1/4”

(2419mm)

71-11/16”

(1818mm)

79-3/16”

(2011mm)

Chimney

6”

*

Elbow

Offset &

Height

15º

Secure

Temp

S2100+

Nova Temp

HT6000

30º

8” 12”

One Length Between Elbows

18” 24” 36” 48”

Two Lengths Between Elbows

8” & 48” 12” & 48” 18” & 48” 24” & 48” 36” & 48” 48” & 48”

A

B

A

3-5/16”

(84mm)

16”

(406mm)

7-3/8”

(187mm)

B

20-11/16”

(525mm)

4-5/16”

(110mm)

19-7/8”

(505mm)

9-3/8”

(238mm)

24-3/16”

(614mm)

5-7/8”

(149mm)

25-11/16”

(652mm)

12-3/8”

(314mm)

29-3/8”

(746mm)

7-7/16”

(189mm)

31-1/2”

(800mm)

15-3/8”

(391mm)

34-9/16”

(878mm)

10-1/2”

(267mm)

43-1/16”

(1094mm)

21-3/8”

(543mm)

44-15/16”

(1141mm)

13-5/8”

(346mm)

54-5/8”

(1387mm)

27-3/8”

(695mm)

55-5/16”

(1405mm)

15-1/2”

(394mm)

61-7/16”

(1561mm)

30-7/8”

(784mm)

61-3/8”

(1559mm)

16-1/2”

(419mm)

65-1/4”

(1657mm)

32-7/8”

(835mm)

64-7/8”

(1648mm)

18-1/16”

(459mm)

71-1/16”

(1805mm)

35-7/8”

(911mm)

70-1/16”

(1780mm)

19-5/8”

(498mm)

76-7/8”

(1953mm)

38-7/8”

(987mm)

75-1/4”

(1911mm)

22-3/4”

(578mm)

88-1/2”

(2248mm)

44-7/8”

(1140mm)

35-5/8”

(2175mm)

25-13/16”

(656mm)

100-1/16”

(2542mm)

50-7/8”

(1292mm)

96”

(2438mm)

Chimney

6” *

Elbow Offset &

Height

--12”

One Length Between Elbows

18” --36” 48” ---

Two Lengths Between Elbows

12” & 48” 18” & 48” --36” & 48” 48” & 48”

15”

A

----

----

4-13/16”

(122 mm)

6-1/8”

(156 mm)

----

----

11”

(280 mm)

14-1/8”

(359 mm)

----

----

16-7/8”

(429 mm)

18-7/16

(468 mm)

----

----

23”

(584 mm)

AC

6”

30”

B

A

----

----

----

----

27-11/16”

(703 mm)

9-3/8”

(238 mm)

33-1/2”

(851 mm)

12-3/8”

(314 mm)

----

----

----

----

50-7/8”

(1292 mm)

21-3/8”

(543)

62-1/2”

(1588 mm)

27-3/8”

(695 mm)

----

----

----

----

72-5/8”

(1845 mm)

32-5/8”

(829 mm)

78-7/16”

(1992 mm)

35-5/8”

(905 mm)

----

----

----

----

95-3/4”

(2432 mm)

44-5/8”

(1134 mm)

B

----

----

25-3/4”

(654 mm)

31”

(787 mm)

----

----

46-1/2”

(1181 mm)

57”

(1448 mm)

----

----

66”

(1676 mm)

71-1/4”

(1810 mm)

----

----

86-7/8”

(2207 mm)

NOTE: With the AC

*

chimney, a starting length of 6” high must be used on top of the fireplace before installing an elbow.

26-3/16”

(665 mm)

107-3/8”

(2727 mm)

50-5/8”

(1286 mm)

97-1/4”

(2740 mm)

Figure 26

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

*

Available from Security Chimneys™

15

16

Starter Section

Straps

OFFSET CHIMNEY INSTALLATION

*

Chimney AC

Support

ACRS

Straps

NOTE: This illustration is not to scale. It represents how the chimney must be supported.

A 30 degree offset only is allowed in the USA and a 45 degree maximum offset is allowed in Canada.

ANGLED WALL RADIATION SHIELD

*

(RSM+ and RSMI30)

When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wall radiation shield must be installed. Only one is required.

NOTE: 45º angle for Canada only (

RSMI45

*

)

In cold climate locations (climates where temperatures will fall below 32°

F / 0° C), we recommend that you use the insulated wall radiation shield since it will maintain the home’s thermal barrier.

Chimney Model *

ASHT+ / HT6103+

(6” dia). Canada only

S-2100+ / HT6000+ /

AC (6” dia).

RSM+ and RSMI30

(RSMI45 - Canada Only)

Angle

30º

45º

Hole Size

283 mm x 781 mm (11-1/8” x 30-3/4”)

283 mm x 518 mm (11-1/8” x 20-3/8”)

30º

30º

327 mm x 881 mm (12-7/8” x 34-11/16”)

380 mm x 972 mm (15” x 38-1/4”)

Table 5

Figure 27

Insulated Wall

OFFSET CHIMNEY INSTALLATION WITH WALL PENETRATION

Rain Cap

Collar

Drywall

Framing

2” x 3”

Roof Flashing

Offset Support

Figure 29

Insulated Wall

Radiation Shield

NOTE: In cold areas it is recommended to protect the chimney in a insulated chase.

Insulated Wall

Radiation Shield

Figure 28

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

*

Available from Security Chimneys™

GLASS CARE

Glass Replacement

The glass used for the Montecito™ fireplace is a high temperature ceramic glass (1,400° F /

760° C). If the glass breaks, it must be replaced with an identical ceramic glass. Tempered glass or ordinary glass will not withstand the high temperatures of the Montecito fireplace.

Replacement glass should be purchased from a

IHP dealer (see “Replacement Parts”, Page 23).

DO NOT OPERATE THE UNIT WITH CRACKED

OR BROKEN GLASS.

Glass Cleaning

The Montecito fireplace is designed to keep the glass clean under normal operating conditions. If the Montecito fireplace is operated continuously with the combustion air controls closed, the glass will tend to get dirty unless the fuel, firebox and glass are maintained at hot temperatures (see “Refueling For Best

Performance”). To clean the glass, there are a number of specially designed cleaners. Your authorized IHP dealer can recommend a suitable cleaner which is available in your area.

Regular household glass cleaners will not clean creosote. Do not use abrasives such as steel pads, steel wool or oven cleaner as they will scratch the glass.

DO NOT USE CHEMICAL GLASS CLEANERS

ON PAINTED SURFACES AS IT MAY CAUSE

THE PAINT TO PEEL.

CAUTION : DO NOT ALLOW WINDOW CLEANER

TO GET IN CONTACT WITH DOOR GASKET OR

PAINT ON FACADE OR DOOR. ONCE CLOSED,

CONTACT OF GLASS CLEANER WITH THE

FIREPLACE FACADE CAN PROVOKE PAINT

PEELING OFF.

Gasket Replacement

Remove the door from the unit (see Page 6) and lay it on a clean unabrasive surface. To replace the gasket, first remove all of the old gasket and gasket cement. Make sure that the surface is totally clean before applying new cement (a high temperature silicone caulking rated at 500° F [260° C], is suitable) or adhesion problems may result. Apply gasket cement to the gasket channel and install the new gasket.

This replacement part is available from your IHP dealer in the following dimensions:

Gasket Length Dimensions

Around

Glass

On Door

Frame

Around

Glass

69

(1753)

73

(1854)

Steel Door

1 x 3/16

(25 x 4.8)

5/8 dia.

(15.9)

69

(1753)

Cast Door

1 x 5/16

(25 x 4.8)

Part No.

PR-SR1685D

PR-SR1823G

PR-SR1823H

On Door

Frame

73

(1854)

5/8 dia.

(15.9)

PR-SR1823G

Table 1

Inches (millimeters)

FIREPLACE INSTALLATION

Locating The Montecito Fireplace

The best location to install your fireplace is determined by considering the location of windows, doors, and the traffic flow in the room where the fireplace is located, allowing space in front of the unit for the hearth extension and the mantel, and taking into consideration the location of the hot air ducts (optional), outside air kit and chimney.

If possible, you should choose a location where the chimney will pass through the house without cutting floor or roof joists (see fireplace dimensions Page 9).

Usually, no additional floor support is needed for the fireplace. The adequacy of the floor can be checked by first estimating the weight of the fireplace system. Weights are given on Page 23. Note the floor construction and consult your local building code to determine if additional support is needed.

The Montecito fireplace may be installed directly on the floor or on a raised base (for proper guidelines, refer to “Hearth Extension

Requirements”) and a minimum of 6’8” (2 m) measured from the base of the appliance to the ceiling is required.

When selecting the location, the chimney outlet position and the direction of the wind are important factor affecting the chimney performance.

To allow a maximum draft and to reduce wind turbulence, the chimney must:

• Penetrate the highest part of the roof.

• Be installed as far as possible of roof offsets, trees or any other obstructions that may cause wind turbulence and back drafts in the chimney.

• The least amount of offsets (elbows) possible. NOTE: A maximum of 2 offsets is

allowed.

Location Recommended

Marginal Location

Wind Direction

Location

Not

Recommended

Location

Not

Recommended

Outside Air Intake

Facing the Wind

Figure 6

17

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

18

CHIMNEY SUPPORT INSTALLATION

Universal Roof Support

This support has three possible uses:

1. For ASHT+

*

/ HT6103+

*

and S-2100+

*

/ HT6000+

*

, it must be used on a roof to support the chimney.

2. It may be used on a floor, ceiling or roof above an offset to support the chimney above the offset.

3. It may be used on a floor, ceiling or roof as a supplementary support.

Table 6 gives maximum height of supported chimney.

NOTE: For the AC

*

chimney, a support section must be used every forty

(40) feet (12 m) instead of the universal roof support (ST).

For roof support installation, refer to the instructions provided with the support.

UNIVERSAL OFFSET SUPPORT INSTALLATION

This support is used to support the chimney above an offset. When the chimney offset is used to traverse a wall this support may be used on the wall to support the chimney. The maximum heights are given in

Table 6. For offset support installation, refer to the instructions provided with the support.

Figure 30

18” (460 mm)

16” (410 mm)

18” (460 mm)

16” (410 mm)

18” (460 mm)

CHIMNEY ADAPTOR

*

(S-2100+ / HT6000+) CANADA ONLY

The fireplace is normally supplied with a chimney adaptor suitable for the ASHT+

*

/ HT6103+

*

chimney. If you want to install a S-2100+

*

/ HT6000+

*

chimney, an adaptor is available (6UCA

*

) (Figure 31). A separate starter section will also be required if AC

*

chimney is installed.

CHIMNEY MODEL

*

ASHT+ / HT6103+ (6” dia).

S-2100+ / HT6000+ (6” dia).

AC (6” dia).

Table 6

MAXIMUM HEIGHT OF

SUPPORTED CHIMNEY

Offset Support

28 feet (8.54 m)

Roof Support

29 feet (8.84 m)

18 feet (5.49 m)

40 feet (12.19 m)

20 feet (6.1 m)

50 feet (15.20 m)

Chimney Adaptor -

Canada only

CHIMNEY CHASE AND MULTIPLE TERMINATIONS

For the purpose of this manual, a chimney chase is considered a part of the chimney system rather than part of a building. The termination must be placed a minimum of 18” (460 mm) above the chase.

For installations where more than one chimney is located in the same chase or within the same area, we suggest that their terminations be separated by at least 16” (410 mm) horizontally, and 18” (460 mm) vertically. This separation is to prevent smoke migrating from one chimney to another (see Figure 30).

Figure 31

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

*

Available from Security Chimneys™

INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATION

WARNING: Before starting the installation, the masonry chimney must be inspected by a qualified chimney sweep.

The following requirements must be respected:

1. The chimney must be absolutely clear of any soot residue or creosote.

Check for cracks, loose or missing bricks that could inhibit correct installation of the liner.

2. The clearance to combustible must be a minimum of 1” between the outside of the masonry and any wood framing or loose insulation.

3. The chimney must be built in accordance with the current building code.

4. No other appliance can be connected to the same chimney.

5. The clearances to combustible for these fireplace connectors are 2” on the side and bottom and 16” at the top.

6. The connector parts are not necessary if the connection between the insulated length and the stainless steel liner is done within the masonry chimney.

Installation:

The chimney must be relined with a stainless steel liner model Tubinox™

*

or Projet

®

SS

*

of the same diameter as the outlet of the fireplace.

For connection at a 30º angle, a special connector (BISUMA30

*

) must be used to connect the liner to the insulated chimney.

* IMPORTANT NOTE - The use of a 45º connector (BISUMA

*

) is approved for use in Canada ONLY. Installations in the USA must use the 30º connector (BISUMA30

*

).

Follow these steps:

1- Position the fireplace in its location. Temporarily install the ASHT+

*

elbow on the top of the fireplace and, using a level, mark with an oval the location where the flue liner will enter the masonry chimney.

2- In the middle of the oval, drill a hole in the masonry chimney at 30º.

3- Increase the size of the hole until a 30º Tubinox

*

liner elbow can be easily slipped through.

4- Slide the liner down from the top of the masonry chimney until you reach the hole level.

5- Slip through the hole a 30º liner elbow and connect it to the liner.

6- Add a small liner section to the liner elbow which will allow the liner to extend at least 12” (measured at the top of the liner) from the masonry chimney.

7- Seal the opening around the liner with high temperature refractory cement.

8- The next steps must be done in the following order:

See typical installation illustrated below.

A. Select the ASHT+

*

length that will fit between the elbow and the liner so that it will slide at least 2” over the liner section (You may need to cut the liner for a better fit).

B. Take that section and the BISUMA30

*

cover and slide it over the liner.

Make sure you have enough opening to be able to install the ASHT+

*

elbow without difficulty.

C. Install the 30º elbow on the fireplace.

D. Slide the length section back down on the elbow and twist lock the two together.

E. Pull the cover down over the length and install the insulation pad over the liner; be careful to cover the liner completely.

F. Slide back the cover over the insulation and fix it in place using the 3 metal screws supplied.

6’ 8”

High-Temp.

Cement

Insulation Pad and Cover

* Insulated

Elbow* ASHT+ or HT6103+

3 Screws

Fireplace

1” Clearance

Firestop

Tubinox* or Projet SS*

Stainless Steel Liner

Tubinox* or Projet SS*

Liner Must Slide at

Least 2” Inside Length

Insulated

Length

Masonry Chimney,

New or Existing

Figure 32

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

*

Available from Security Chimneys™

19

20

OPTIONAL INSTALLATION ACCESSORIES

Installation Accessories

Description

Facades (Required - Order Separately)

Montecito™ Facade Black, MFBK

Montecito Facade Hammered Steel, MFMC

Doors (Required - Order Separately)

Montecito Door, Black, MCBK

Montecito Door, Hammered Steel, MCMC

Cast Iron Door, Black, BWBK

Outside Air Kit (included with fireplace)

Outside Air Coupler To Connect Outside Air (UZI) To Fireplace, UZIAD

Outside Air Ducting - includes 4” insulated flex x 10’ long, UZI

Gravity Kit

Gravity kit: Complete double duct system includes: 2 elbows

90º, 2 telescopic lengths, 2 grill supports and 2 black grills,

2 fireplace adaptors, 7B30ZK-1

Gravity Kit Accessories

Elbow 90º, 8” dia., 7B26ZE90

Elbow 45º, 8” dia., 7B26ZE45

Telescopic length, 8” dia. (15” to 26”), 7B26ZLA

Adjustable length 8” dia (2” - 5”), 7B26ZL2A

Length two (2) feet, 8KL2

Length one (1) feet, 8KL1

Wall radiation shield, 8” I.D., 7B26ZR

Cat./ Part No.

H4843

H4845

H4846

H4848

H0516

UZIAD

UZI

H8947

H8948

H8949

H8950

H8951

H8954

H8953

H8952

Fireplace Kits

Description

Rigid firescreen

Central Forced Air Kit Accessories

u

Central Forced Air Kit, Central forced air kit including: blower

(BISZY), flex adaptor (BISAF), 2 clamps, variable speed control (VRUW), thermo-disk (VTU), fan to flexible pipe adapter (BISAVF), back draft damper (BISBD), aluminium tape, BISFWK-1

Flexible pipe 5” I.D. x 15 ft. Long, 5FLEX15

Flexible pipe 5” I.D. x 30 ft. Long, 5FLEX25

Heating and cooling thermostat, 24V, HCTW

Cat./ Part No.

BUCEBWZN

BISFWK-1

5FLEX15

5FLEX25

HCTW u

longer qualifies for EPA certification.

* For installation, follow the instructions included with the Central

Forced Air Kit.

REPLACEMENT PARTS LIST

Montecito™ Replacement Parts

Description

Blower (heat activated on/off pre-wired), UZY5

Blower motor speed control (wall mount), VRUW

Snap Disc, Blower

Baffle refractory (2 pieces)

Back refractory

Right side refractory

Left side refractory

Bottom refractory

Front refractory, right side

Front refractory, left side

Door handle

Hinge Assembly, Fireplace and Door

Decorative Screw Caps, Black (2)

Decorative Screw Caps, Brushed Nickel (2)

Ceramic glass panel

Secondary air tube

Cast-iron Log Retainer Supports - Grate (2)

Cast Iron Log Retainer Bar

Gasket Kit, Glass, 69” (1 x 5/16”) (steel and cast doors)

Gasket Kit, Steel Door Frame, 73” (5/8” dia.)

Gasket Kit, Cast Door Frame, 73” (5/8” dia.)

Touch-up Paint, Aerosol, Black Metallic SBMB6309

Touch-up Paint, Charcoal (for hammered steel facade)

Coupler, Outside Air (connects UZI to fireplace)

Coupler for AC Chimney (connects ACZI to fireplace)

Blower 250 CFM for central forced air kit, BISZY

Blower variable speed control with decorative wall plate for (BISZY), VRUW

Thermo-disk, on/off blower control (for BISZY), VTU

Blower to flexible pipe adaptor, BISAVF

Backdraft damper, BISBD

Fireplace to Flex adaptor and 2 clamps, BISAF

Part/Cat. No.

UZY5

VRUW

VTU

PR-ISO2205

PR-SR2618

PR-SR2619D

PR-SR2619G

PR-SR2201

PR-SR2202D

PR-SR2202G

PR-SR1787

PR-SR2395TCE

PR-SACMEFBK

PR-SACMEFBN

PR-SR2222-1

PR-SR2271

PR-SR2324

PR-SR2323

PR-SR1823H

PR-SR1685D

PR-SR1823G

H8159

PR-P6201

UZIAD

H3274

BISZY

VRUW

VTU

BISAVF

BISBD

BISAF

Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards.

SPECIFICATIONS

Cat. No.

H4841

Model

Montecito

Product Reference Information

Weight 300 lbs

Height

Width

Depth

Firebox W x H x D - measured in front

Chimney Weight ASHT (6” dia)

Chimney Weight AC (6” dia.)

Chimney weight S-2100+ (6” dia.)

36”

36”

24-1/2”

22” x 11-3/4” x 12”

6.25 lb per linear foot

3.25 lb per linear foot

10.8 lb per linear foot

CLEARANCE TO COMBUSTIBLES

The following clearances meet the minimum requirements for a safe installation;

Side wall: 17” (324 mm) measured from the fireplace side

Ceiling: 6’ 8” (2,032 mm) measured from the base of the fireplace

Fireplace enclosure:

Bottom: 0”

Side: 0” to spacer

Back: 0” to spacer

Top: Do not fill the space above the fireplace with any material

(Except the wood framing. See Page 9, Figure 8)

Chimney: 2” (50 mm)

Mantel: 42” (1067 mm) measured from the base of the fireplace.

21

22

SECURITY CHIMNEYS™ - PARTS AND COMPONENTS LISTS

The components listed below must be ordered from Security Chimneys International™. Contact your Security Chimneys Distributor or Dealer for ordering information.

Security Chimneys International Limited

2125 Monterey, Laval, Quebec

Canada, H7L 3T6 www.securitychimneys.com

450-973-9999

1-800-361-4909 (USA)

1-800-667-3387 (Canada)

Fireplace Model MONTE - Approved Venting Components manufactured by Security Chimneys International™ only.

Secure Temp ASHT 1” High Temp. Insulated Stainless Steel Chimney

6” I.D. and 8” O.D., Double-Wall Stainl. Steel, Listed to CAN/UCL-S604 and UL-103HT

Description Part/Cat. No.

Lengths and Misc. Chimney Components

8” length, 6” Dia., 6L8

12” length, 6” Dia., 6L12

18” length, 6” Dia., 6L18

24” length, 6” Dia., 6L24

36” length, 6” Dia., 6L36

48” length, 6” Dia., 6L48

Adjustable Length 12”, 6” Dia., 6LA

15º elbow, 6” Dia., 6E15

30º elbow, 6” Dia., 6E30

Rain Termination Cap, 6” Dia., 6CC

Spark Arrester Screen (universal spark arrester band), PE

Wall Band, BM

Supports

Offset Support, SO

Roof Support, ST

Roof Brace, BS2

Firestops

Firestop, 6BF

Radiation Shield, 6RS

Insulated Attic Radiation Shield, 6RSA

Insulated Wall Radiation Shield, 6RSM

Insulated Wall Radiation Shield, 30º, 6RSMI30

Uninsulated Wall Radiation Shield, 30º, 6RSM30

Attic Radiation Shield

Roof Flashings

Flat Roof Flashing, 6FR

1/12 - 7/12 (5º - 30º), 6FAR

8/12 - 12/12 (30º - 45º), 6FBR

Storm Collar, 6FC

SO

ST

BS2

6BF

6RS

6RSA2

6RSM

6RSMI30

6RSM30

H0487

6FR

6FAR

6FBR

6FC

6L8

6L12

6L18

6L24

6L36

6L48

6LA

6E15

6E30

6CC

PE

BM

• 6” diameter chimney - AC (air cooled), Secure Temp

®

ASHT+ (or Nova Temp

®

HT6103+) and Secure Temp S-2100+ (or Nova Temp HT6000+).

6” diameter chimney for relining masonry chimneys - Tubinox™ chimney (or

Projet

®

SS), 6” diameter with adaptor for installation in a masonry chimney.

NOTES:

j Secure Temp S-2100+ k

Secure Temp ASHT+ l

chimney is used, a chimney adaptor for that chimney will be required.

m

Chimney Adaptor (S-2100+ / HT6000+) for CANADA ONLY - If you want to install a S-2100+ / HT6000+ chimney, an adaptor is available (6UCA).

climates (climates where temperatures will fall below 32° F / 0° C). When using AC chimney, an AC6SB (H3779) starter section must be used before installing an elbow. When an offset is needed immediately off the top of the fireplace, an elbow starter section, AC6SB30 (H3780), is available.

SECURITY CHIMNEYS™ - PARTS AND COMPONENTS LISTS

The components listed below must be ordered from Security Chimneys International™. Contact your Security Chimneys Distributor or Dealer for ordering information.

Security Chimneys International Limited

2125 Monterey, Laval, Quebec

Canada, H7L 3T6 www.securitychimneys.com

450-973-9999

1-800-361-4909 (USA)

1-800-667-3387 (Canada)

(AC) Air-Cooled Chimney System*

6” I.D. and 11” O.D. Air Cooled, Stainl. Steel inner and zinc coated steel exterior

* AC Chimney is NOT recommended at elevations above 4,000 feet or in cold climates

(climates where temperatures will fall below 32° F / 0° C).

Description Cat./Part No.

One of the following adaptors is required if installing an AC chimney system

Starter Section (adaptor), 6”, AC, AC6SB

Starter 30º Elbow, 6” AC, AC6SB30

H3779

H3780

The following outside air kit is required if installing an AC chimney system

Chimney Outside Air Kit (flex, insulation, outside register and coupling), ACZI

H1967

Lengths and Misc. Chimney Components

12” Length, 6” Dia. x 12” Long, AC6L12 H0472

18” Length, 6” Dia. x 12” Long, AC6L18

36” Length, 6” Dia. x 36” Long, AC6L36

48” Length, 6” Dia. x 48” Long, AC6L48

15º Elbow, 6” Dia., AC6E15

30º Elbow, 6” Dia., AC6E30

Rain Termination Cap, 6” Dia., AC6CPR

Spark Arrester Screen (universal spark arrester band), PE

Wall Band, XBM

Offset Support, SO

Supports

H0473

H0474

H0475

H0476

H0477

H0478

PE

XBM

Support Section, AC6SL

Roof Support, ST

Roof Brace, BS2

Roof Flashings

Flat Roof Flashing, ACF

1/12 - 7/12 (5º - 30º), AC Adj. Roof Flashing, FA

8/12 - 12/12 (30º - 45º), AC Adj. Roof Flashing, FB

SO

H0481

ST

BS2

H0494

H0495

H0496

H0500 Storm collar, ACFC

Misc.

Telescopic attic radiation shield, ACRST

Firestop, ACBF

Radiation Shield, ACRS

Attic Radiation Shield, ACRSA

Insulated Wall Radiation Shield, 30º, ACRSMI30

H0498

H0485

H0486

H0487

H0489

Tubinox™ LL Chimney Lining System

Rigid Stainless Steel Liner For Relining A Masonry Chimney, 6” Diameter

Listed to ULC-S635M, UL-1777 and ULC-S640M at 2100º F

Description

6” Length, 6” Dia., 6LL6

12” Length, 6” Dia., 6LL12

24” Length, 6” Dia., 6LL24

36” Length, 6” Dia., 6LL36

48” Length, 6” Dia., 6LL48

Adjustable Length (7” to 11”), 6” Dia., 6L7A

Split Base Tee, 6” Dia., 6LT

Tee Cap, 6” Dia., 6TCS

Twist Lock Tee Cap, 6” Dia., 6LTC

Elbow 30º, 6” Dia., 6LE30

Elbow 45º, 6” Dia., 6LE45

Elbow 90º, 6” Dia., 6LE90

Rain Termination Cap (regular), 6” Dia., 6LCS

Rain Termination Cap (deluxe), 6” Dia., 6LCC

Supports

Top Support, 6LST

Support Assembly, 6LSA

Interior Support, 6LSB

Adaptor Flexible Pipe (male), 6LAAM

Adaptor Flexible Pipe (female), 6LAAF

Stainless Steel Flex - five (5) feet Long, 6LLFLEX

Adjustable Insulated Wall Radiation Shield 6” - 12”, 6LRSMI

Adaptors to Masonry Chimney

Masonry Chimney Adaptor, 45º, BISUMA

(for use with Tubinox liner) CANADA ONLY

Masonry Chimney Adaptor, 30º, BISUMA30

(for use with Tubinox liner)

Gravity Kit Accessories

Elbow 90º, 8” dia., 7B26ZE90

Elbow 45º, 8” dia., 7B26ZE45

Telescopic length, 8” dia. (15” to 26”), 7B26ZLA

Adjustable length 8” dia (2” - 5”), 7B26ZL2A

Wall radiation shield, 8” I.D., 7B26ZR

Black grill with support, 7B30ZO

Brass grill (for 7B30ZK), 7B30ZGB

Length one (1) feet, 8KL1

Length two (2) feet, 8KL2

Length three (3) feet, 8KL3

Length four (4) feet, 8KL4

Length five (5) feet, 8KL5

Cat./Part No.

6LST

6LSA

6LSB

6LAAM

6LAAF

6LLFLEX

6LRSMI

7B26ZE90

7B26ZE45

7B26ZLA

7B26ZL2A

7B26ZR

7B30ZO

7B30ZGB

8KL1

8KL2

8KL3

8KL4

8KL5

6LT

6TCS

6LTC

6LE30

6LE45

6LE90

6LCS

6LCC

6LL6

6LL12

6LL24

6LL36

6LL48

6L7A

BISUMA

BISUMA30

23

WARRANTY

Your fireplace is covered by a limited warranty. Please read the warranty to be familiar with its coverage.

Retain this manual. File it with your other documents for future reference.

PRODUCT REFERENCE INFORMATION

We recommend that you record the following important information about your fireplace. Please contact your IHP dealer for any questions or concerns. For the number of your nearest IHP dealer, please call

1-800-655-2008.

REPLACEMENT PARTS

See Page 21 for a complete replacement parts list. Use only parts supplied from the manufacturer.

Normally, all parts should be ordered through your IHP distributor or dealer. Parts will be shipped at prevailing prices at time of order.

When ordering repair parts, always give the following information:

1. The model number of the appliance.

2. The serial number of the appliance.

3. The part number.

4. The description of the part.

5. The quantity required.

6. The installation date of the appliance.

If you encounter any problems or have any questions concerning the installation or application of this system, please contact your dealer.

IHP

1508 Elm Hill Pike, Suite 108

Nashville, TN 37210

Visit us at www.LennoxHearthProducts.com

1-800-655-2008

Your Fireplace's Model Number ________________________________________

Your Fireplace's Serial Number ________________________________________

The Date On Which Your Fireplace Was Installed ___________________________

Your Dealer's Name _________________________________________________

Your Dealer's Phone Number __________________________________________

24

IHP reserves the right to make changes at any time, without notice, in design, materials, specifications, and prices, and also to discontinue colors, styles, and products.

Consult your local distributor for fireplace code information.

LENNOX

®

, the LENNOX design, DAVE LENNOX, the image of DAVE LENNOX and other related

LENNOX marks are registered or common law trademarks of Lennox Industries Inc. and are used with permission.

Printed in U.S.A. © 2006 IHP LLC

P/N 850037M REV. M 05/2013 1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement