Joint Host-Network Optimization for Energy

Joint Host-Network Optimization for Energy
Joint Host-Network Optimization for
Energy-Efficient Data Center Networking
Hao Jin∗ , Tosmate Cheocherngngarn∗ , Dmita Levy∗ , Alex Smith† , Deng Pan∗ , Jason Liu∗ , and Niki Pissinou∗
∗
†
Florida International University, Miami, FL
Terra Environmental Research Institute, Miami, FL
Abstract—Data centers consume significant amounts of energy.
As severs become more energy efficient with various energy
saving techniques, the data center network (DCN) has been
accounting for 20% or more of the energy consumed by the
entire data center. While DCNs are typically provisioned with
full bisection bandwidth, DCN traffic demonstrates fluctuating
patterns. The objective of this work is to improve the energy
efficiency of DCNs during off-peak traffic time by powering
off idle devices. Although there exist a number of energy
optimization solutions for DCNs, they consider only either the
hosts or network, but not both. In this paper, we propose a
joint optimization scheme that simultaneously optimizes virtual
machine (VM) placement and network flow routing to maximize
energy savings, and we also build an OpenFlow based prototype
to experimentally demonstrate the effectiveness of our design.
First, we formulate the joint optimization problem as an integer
linear program, but it is not a practical solution due to high
complexity. To practically and effectively combine host and
network based optimization, we present a unified representation
method that converts the VM placement problem to a routing
problem. In addition, to accelerate processing the large number
of servers and an even larger number of VMs, we describe a
parallelization approach that divides the DCN into clusters for
parallel processing. Further, to quickly find efficient paths for
flows, we propose a fast topology oriented multipath routing
algorithm that uses depth-first search to quickly traverse between
hierarchical switch layers and uses the best-fit criterion to
maximize flow consolidation. Finally, we have conducted extensive
simulations and experiments to compare our design with existing
ones. The simulation and experiment results fully demonstrate
that our design outperforms existing host- or network-only
optimization solutions, and well approximates the ideal linear
program.
Index Terms—Data center networks; virtual machine migration; multipath routing; energy efficiency.
I. I NTRODUCTION
Public and private data centers are becoming popular, since
they achieve economies of scale with hundreds of thousands of
servers [20], e.g. about 300,000 servers in Microsoft’s Chicago
data center [3]. The huge number of servers in data centers
consume significant amounts of energy. It is estimated [2]
that national energy consumption by data centers in 2011 was
more than 100 billion kWh, representing a $7.4 billion annual
electricity cost. As a result, energy efficiency of data centers
has attracted significant attention in recent years [13], [22].
With the improvement of sever energy efficiency, the data
center network (DCN), the other important component of a
data center, has been accounting for 20% ore more [4], [25]
of the energy consumed by the entire data center. With the
huge number of servers in a data center, the DCN needs
proportionally large bandwidth to interconnect the servers.
In addition, a DCN is typically provisioned with full bisection bandwidth [5], [11], [12], [21] to support burst all-toall communication. However, since DCN traffic demonstrates
fluctuating patterns, the fully provisioned bandwidth cannot
be always well utilized, resulting in resource underutilization
and energy waste. For example, Figure 1 shows a 7-day traffic
sample of a core router interface from a data center service
provider. We can clearly see a wave pattern, with the highest
instant traffic volume at about 13Gbps, and the lowest at
about 2Gbps. Different colors in the figure represent different
transport layer protocols, with TCP being the majority.
The key for DCNs to achieve energy conservation during
off-peak traffic hours is to power off idle devices when possible. There exist a number of DCN energy saving solutions in
the literature, which can be divided into two broad categories:
optimizing network flow routing [14] and optimizing virtual
machine (VM) placement [19]. The former consolidates flows
to a smaller number of links, and thus leaves more idle
links and consequently switches to be powered off. The latter
consolidates VMs to physical servers in such a way that VM
pairs with more traffic are placed closer, to avoid heavy flows
traversing long paths.
To the best of our knowledge, existing DCN energy saving
solutions consider only either the hosts or the network, but
not both. In this paper, we study the joint host-network optimization problem to improve the energy efficiency of DCNs.
The basic idea is to simultaneously consider VM placement
and network flow routing [24], so as to create more energy
saving opportunities. The simplest way to combine host and
network based optimization is just to naively first determine
the VM placement and then the flow routing. Unfortunately,
the existing VM placement algorithm [19] is not practical,
since it does not consider the bandwidth capacity constraints
of links, assumes fixed VM memory sizes, and has high time
complexity of O(|V |4 ), where V is the set of VMs.
For effective joint host-network optimization, the first challenge is how to simultaneously consider the two types of
optimization problems. To address the challenge, we present a
unified representation method that converts the VM placement
problem as a routing problem, so that a single optimization
solution can apply to both types of problems. Further, the
second challenge is how to accelerate the processing of the
huge number of VMs in a data center. To this end, we propose
Fig. 1.
Fluctuating DCN traffic pattern.
a parallelization approach that divides the DCN into clusters
based on their subnet IP addresses, and processes the clusters
in parallel for fast completion. Finally, the third challenge
is how to quickly find efficient routing paths for the flows.
To solve this problem, we propose a topology oriented fast
multipath routing algorithm, which uses depth-first search to
quickly traverse between the hierarchical layers in a DCN, and
the best-fit criterion to maximize flow consolidation.
In this paper, we propose a joint host-network energy
optimization scheme that combines VM placement and flow
routing optimization, and build an OpenFlow based prototype to experimentally demonstrate the effectiveness of our
design. We first formulate the problem as an integer linear
program. Since integer linear programming is NP-complete
and not suitable for practical deployment, we then propose
a series of techniques to quickly and effectively solve the
joint optimization problem. In addition, we have implemented
the proposed scheme in a simulator and a prototype, and
conducted extensive evaluations to compare it with existing
solutions. The simulation and experiment results fully demonstrate that our scheme outperforms existing host- or networkonly optimization solutions, and well approximates the ideal
linear program.
The rest of the paper is organized as follows. Section II
reviews the related work. Section III formulates the problem. Section IV elaborates our design guidelines. Section V
presents the joint host-network energy optimization scheme.
Section VI describes a prototype implementation. Section VII
shows the simulation and the experiment results. Section VIII
discusses the broadcast and safety margin issues. Finally,
Section IX concludes the paper.
II. R ELATED W ORK
In this section, we briefly review existing energy saving
solutions for DCNs and more broadly wide area networks.
Those solutions can be divided into two broad categories:
network-side optimization and host-side optimization.
A. Network-Side Optimization
In the first category, ElasticTree [14] is a DCN power
manager to find the set of switches and links that can
accommodate the traffic and consume the minimum power.
In addition, ElasticTree also addresses the robustness issue
so that the optimized network has sufficient safety margins
to prepare for traffic surges and network failures. GreenTE
[27] manipulates the routing paths of wide area networks, so
that the least number of routers shall be used to satisfy the
performance constraints such as traffic demands and packet
delays. Energy conservation can then be achieved by shutting
down the idle routers and links without traffic. [10] proposes
an energy saving scheme for the idle cables in bundled links.
By reorganizing network traffic and powering off individual
cables as well as the associated line cards in the low-utilized
bundles, the scheme achieves a theoretical 79% improvement
on energy efficiency for backbone networks. [4] indicates that
a flattened butterfly DCN topology is more energy efficient
than the folded Clos topology. [16] presents a large power
profile study for the power manager Urja in an enterprise
network, which saves over 30% of the network energy. [25]
establishes a model of energy-aware routing in DCNs, and
designs a heuristic to achieve the goal.
B. Host-Side Optimization
In the host-side optimization category, one approach is
to optimize VM placement using live migrations [8], which
will help consolidate VMs into fewer physical servers and
traffic flows into fewer links. [19] proposes a traffic-aware VM
placement scheme that localizes large traffic chunks and thus
reduces loads of high layer switches. The scheme achieves energy conservation by shutting down idle servers and switches
after the placement. [26] studies the VM consolidation problem in the context of dynamic bandwidth demands. The
problem is formulated as a stochastic bin packing problem and
proved as NP-hard. The paper then proposes an approximation
algorithm, which uses fewer servers while still satisfies all the
performance constraints. The second host-side optimization
approach is to improve the energy proportionality on the server
itself. PowerNap [18] is an energy saving scheme for servers to
quickly switch between two states: a high-performance active
state to transmit traffic, and an idle state with low power to
save energy.
III. P ROBLEM F ORMULATION
The joint host-network energy optimization problem is a
variant of the multi-commodity problem [9], and can be
formulated as a linear program. The optimization objective
is to minimize the power consumption of all the servers,
switches, and links in a DCN. Recent studies [14], [17], [23]
indicate that power consumption of servers and switches in
data centers can be roughly modeled as linear functions, which
are suitable for linear programming. Even with non-linear
power functions, approximation techniques can help convert
them to piece-wise linear ones.
Model a DCN as a directed graph G = (S ∪ X, L),
where a node s ∈ S is a physical server, a node x ∈ X
is a switch, and an edge (ni , nj ) ∈ L is a link connecting
TABLE I
N OTATIONS FOR P ROBLEM F ORMULATION
Notation
v, s, x, f
(ni , nj )
V, S, X, L, F
DS(v)
md(v)
mc(s)
src(f ), dst(f )
bd(f )
bc(ni , nj )
p(∗)
on(∗)
host(s, v)
route(f, (ni , nj ))
Meaning
virtual machine, server, switch, or flow
link connecting two nodes ni and nj , with one node being a switch, and the other being be a switch or server
set of virtual machines, servers, switches, links, or flows
potential migration destination servers of VM v
memory demand of VM v
memory capacity of server s
source or destination VM of flow f
bandwidth demand of flow f
bandwidth capacity of link (ni , nj )
linear power function of ∗, where ∗ may be a server, switch, or link
decision variable: 1 or 0 if ∗ is powered on or off, where ∗ may be a server, switch, or link
decision variable: 1 or 0 if VM v is or not hosted on server s
decision variable: 1 or 0 if flow f is or not routed through link (ni , nj )
a switch and a server or two switches. Assume that V is
the set of VMs, and a VM v ∈ V must be hosted by a
server s, denoted by host(s, v) = 1. When a server hosts
a VM, the former provides the latter with various resources,
such as memory space and CPU time, and we use memory
space as a representative of such resources. Each server s has
a memory capacity mc(s), and each VM v has a memory
demand md(v). Due to constraints such as subnet IP addresses
and hardware configurations, a VM v has a restricted set of
migration destination servers, denoted as DS(v) ⊂ S. Use
on(∗) to denote that a device ∗ is powered on, which may
be a switch, link, or sever, and use p(∗) to denote the power
consumption of the device ∗.
Assume that f ∈ F is a flow in the DCN. f is defined
as a triple f = (src(f ), dst(f ), bd(f )), where src(f ) is the
source VM, dst(f ) is the destination VM, and bd(f ) is the
bandwidth demand. Use route(f, (ni , nj )) to denote whether
flow f is routed through link (ni , nj ). fk (xi , xj ) can only
be either 1 or 0 to prohibit splitting a single flow among
multiple paths. The reason is that, as seen in Figure 1, more
than 99% of data center traffic flows are TCP ones [6], which
will suffer performance degradation with out-of-order packet
delivery. Note that a link (ni , nj ) ∈ L has a bandwidth
capacity bc(ni , nj ).
With the above notations (summarized in Table I), we can
thus formulate the joint optimization problem as the following
linear program. Equation 1 is the objective function, simply
to minimize the total power consumption of all the switches,
links, and servers.
Equations 2 to 4 define the VM and server related constraints. Specifically, Equation 2 states the server-VM correlation constraint, i.e. only a powered on server can host VMs.
Equation 3 states the server memory capacity constraint, i.e.
the total memory demand of all the VMs hosted by a server
cannot exceed its memory capacity. Equation 4 states the VM
migration destination constraint, i.e. a VM can only be hosted
by one of its destination servers.
Equations 5 to 10 define flow and link related constraints.
Specifically, Equation 5 states the flow source/destination
constraint, i.e. a flow cannot start/end at a server that is not
hosting the source/destination VM. Equation 6 states the flow
demand satisfaction constraint, which means that if the source
and destination VMs of a flow are hosted by the same server,
minimize
p(x) +
x∈X
p(ni , nj ) +
p(s) (1)
s∈S
(ni ,nj )∈L
subject to
∀s ∈ S, ∀v ∈ V, host(s, v) ≤ on(s)
md(v)host(s, v) ≤ mc(s)on(s)
∀s ∈ S,
(2)
(3)
v∈V
∀v ∈ V,
host(s, v) = 1,
s∈DS(v)
host(s, v) = 0
(4)
s∈S\DS(v)
∀f ∈ F, ∀s ∈ S
route(f, (s, x)) ≤ host(s, src(f )),
x∈X
route(f, (x, s)) ≤ host(s, dst(f ))
(5)
∀f ∈ F, ∀s ∈ S
host(s, src(f )) − host(s, dst(f ))
route(f, (s, x)) −
route(f, (x, s))
=
(6)
x∈X
x∈X
x∈X
∀f ∈ F, ∀x ∈ X
route(f, (n, x)) =
route(f, (x, n)) (7)
n∈S∪X
n∈S∪X
∀(ni , nj ) ∈ L,
on(ni , nj ) ≤ on(ni ), on(ni , nj ) ≤ on(nj )
∀(ni , nj ) ∈ L, on(ni , nj ) = on(nj , ni )
∀(ni , nj ) ∈ L,
bd(f )route(f, (ni , nj )))
(8)
(9)
f ∈F
≤ bc(ni , nj )on(ni , nj )
∀x ∈ X, p(x) = α(x)on(x) + β(x)
(10)
on(x, n) (11)
(x,n)∈L
∀(ni , nj ) ∈ L, p(ni , nj ) = γ(ni , nj )on(ni , nj )
∀s ∈ S, p(s) = δ(s)on(s) + (s)
host(s, v)
(12)
(13)
v∈V
then the flow can be transmitted using the local bus of the
sever, without traversing any switches; otherwise, the flow
must start at the server hosting the source VM and end at the
server hosting the destination VM. Equation 7 states the switch
flow conservation constraint, i.e. a switch can only transmit
flows but not generate or destroy any. Equation 8 states the
node-link correlation constraint, i.e. only a powered on switch
can have active links. Equation 9 states the bidirectional link
power constraint, i.e. both directions of a link should have the
same on/off status [14]. Equation 10 states the link bandwidth
capacity constraint, i.e. the total bandwidth demand of all the
flows through a link cannot exceed its bandwidth capacity.
Equations 11 to 13 are sample power functions for switches,
links, and servers. Equation 11 defines that a powered on
switch x consumes α(x) base power, and each active port
consumes additional β(x) power [14]. Equation 12 defines
that an active link (ni , nj ) consumes 2γ(ni , nj ) power, or
γ(ni , nj ) for each direction. Equation 13 defines that a server
s consumes δ(s) base power, and each hosted VM consumes
additional (s) power due to increased CPU usage [23].
Since integer linear programming is NP-complete, the above
solution is not a practical one, but it can still be an ultimate
bench mark to evaluate other approximation solutions.
IV. D ESIGN G UIDELINES
In this section, we elaborate our design guidelines to quickly
and efficiently solve the joint optimization problem.
A. Unified Representation of Both Types of Optimization
For effective joint optimization, the first challenge is that
there are two types of optimization, i.e. VM placement and
flow routing, and it is not clear how to simultaneously consider them. We propose a unified representation method that
converts the VM placement problem to a routing problem, so
that a single solution can apply to both optimization problems.
DCNs are typically organized in a multiple-layer hierarchical
structure. For example, Figure 2(a) shows a fat tree based DCN
with core, aggregation, and top-of-rack (ToR) three layers of
switches, and an additional layer of servers.
The key observation is that the VM-server relationship is
similar to that of sever-switch. A VM can select to reside on
one of multiple allowed servers, and send its traffic through
the physical network adapter of the hosting server. This is
similar to the selection made by a server to pick one of
multiple connected ToR switches to send its traffic. Inspired
by the observation, we add an additional hierarchical layer of
VMs. In detail, we create in the graph a new node for each
VM, and use an edge to connect it with a server if it can
migrate to the server. Figure 2(b) shows a simple example,
where v1 , v2 , and v3 can migrate to any server connected
by the same aggregation switch, and v4 can migrate to any
server connected by the same ToR switch. In the optimization
process, we search routing paths for the flows between VM
pairs. If a VM has a path to a server in the optimization result,
then the VM will be hosted by the server. In this way, we
provide a unified view to solve both optimization problems.
The next challenge is then to determine the capacity of the
newly added edges between VMs and servers. Theoretically, a
server can sustain a very large amount of traffic between two
hosted VMs by the local bus, and therefore the bandwidth
capacity constraints are not important for VM-server edges.
However, the servers do have memory capacity constraints
with the VMs. To reflect such constraints, we create a dummy
node for each server, and use an edge to connect them whose
capacity will be the memory capacity of the server. We now
let the VMs connect to the dummy node instead of the server.
Specifically, if a VM can migrate to a server, the VM has an
edge with infinite capacity connecting to the dummy node of
the server. When search a path for a flow between the dummy
node and the server or vice versa, the demand of the flow
will be the memory demand of the closer end VM instead of
bandwidth demand. In this way, the VMs connected to a server
is constrained by the server memory capacity. Figure 2(c)
shows the results after adding the dummy nodes to Figure 2(b).
Finally, there is a difference between a VM node and a
physical server node. While a server can send different flows to
different ToR switches, a VM has to send all its flows through
the same physical server. In other words, a VM can select
only one of the links connecting to different dummy nodes. If
a VM has multiple traffic flows, all of them should share the
same path between the VM and the hosting server.
B. Cluster based Parallel Processing
To accelerate processing the huge number of VMs in a data
center, we propose a parallelization approach that divides the
DCN into clusters to reduce the problem size, and processes
the clusters in parallel for fast completion. The design is
based on the requirement that live VM migration needs to
keep ongoing network connections and therefore the current IP
address [21]. Although with existing techniques such as mobile
IP, it is possible for an IP address to move into a different
subnet (or a foreign network in the term of mobile IP) and
keep the ongoing connections, there is an expensive overhead
caused by triangle routing [15]. As a result, we assume that
a VM will only migrate within its own subnet [21], which
consists of a fixed set of servers connecting to the same router
interface by the predefined wiring. Note that a VM may not
be able to migrate to every server in the subnet because of
other constraints, such as different hardware configurations.
The main idea is to organize the servers and VMs in
the same subnet as a cluster, and conduct intra- and intercluster processing separately at reduced scales. For intracluster processing, we find the paths for all traffic flows
between the VMs in the cluster, and as a result determine
the placement of such VMs. If a VM has only inter-cluster
flows, i.e. to VMs in other clusters, we simply calculate its
placement according to its memory and bandwidth demands.
The reasoning is that the DCN topology is usually symmetric,
and VM placement anywhere in the cluster is not likely to
affect inter-cluster routing.
The advantages are two-fold. First, by dividing the problem
into a few smaller scale ones, the parallelization approach
reduces the solution search space and allows fast completion.
Second, since intra-cluster processing of different clusters are
V1
V2
V3
V4
(a) Initial state.
V1
V2
V3
V4
(b) Adding hierarchical layer of VMs.
When there are multiple available links to the next hierarchical layer, the best-fit criterion selects the one with the best
matching capacity, i.e. the smallest and sufficient capacity,
so as to consolidate the flows to a few links and improve
energy conservation. The first-fit criterion achieves O(log N )
time complexity to select from N links by conducting binary
search on a sorted list. Compared with worst-fit that distributes
flows to available links in a load balancing way, best-fit
maximizes flow consolidation. A concern is then whether the
flow consolidation by best-fit will exhaust bandwidth of a
specific link, and block a future flow that has to use this link.
Fortunately, a switch in a typical DCN has more than one link
to switches in the neighboring layers for path redundancy, and
therefore the probability for all the links to be unavailable is
small. Further, exhaustive depth-first search with backtracking
guarantees to explore every possible path, and we observe
that all the three selection criteria have similar routing success
ratios, close to 100% under reasonable traffic loads, as shown
in Section VII.
As the initialization, the scheme uses the unified representation method in Section IV-A to show all the VMs, servers, and
switches in a graph. The scheme first processes each cluster,
which is the subgraph corresponding to the subnet, and then
searches paths between the subgraphs for inter-cluster flows.
A. Intra-cluster Processing
V1
V2
V3
V4
(c) Adding dummy nodes for memory capacity constraints.
V1
V2
V3
V4
(d) Optimization results.
Fig. 2.
Unified representation of VM placement and flow routing.
independent, it can be done in parallel to reduce the total
processing time.
V. H OST-N ETWORK J OINT O PTIMIZATION S CHEME
With the above design guidelines, we now present a fast
topology oriented multipath routing algorithm to quickly
search paths for the intra- and inter-cluster flows. The design
utilizes the hierarchical feature of DCN topologies to conduct
fast routing. The basic idea is to use depth-first search to
find a sequence of best-fit links for the flow. Since a path
usually includes links connecting nodes at different layers,
depth first search can quickly traverse the layers. If the search
has exhausted all the links in a layer and cannot proceed
further, it is necessary to backtrack to the previous layer and
try the next candidate. For easy description, we define the VMs
to be the lowest layer, and the upstream direction to be from
a lower layer node to a higher layer one.
Intra-cluster processing starts with sorting the VMs in the
cluster by their memory demands in a decreasing order, for
two reasons. First, VM migration consumes energy, which
is proportional to the VM memory image size since VM
migration copies the VM memory image between servers [8].
By sorting the VM memory demands, we intend to keep the
VMs with large memory images intact and move those with
small ones. Second, the scheme will use best-fit decreasing
for VM placement, since it has better performance than bestfit [9]. This will result in a smaller number of hosting servers.
Next, the scheme searches paths for intra-cluster flows
using the depth-first best-fit rule. The scheme picks among
the VMs with intra-cluster flows the one with the largest
memory demand, and processes its intra-cluster flows one by
one. Initially, neither the source nor the destination VM has
found a hosting server, the path will include three possible
sections: VM-to-server, server-to-switch-to-server, and serverto-VM. Note that if the two VMs migrate to the same server,
the path does not need to traverse any switch.
The first step of the path searching is to determine the
necessary layer to connect the source and destination VMs.
Hosts in DCNs usually have IP addresses corresponding to
their topological locations [7]. For example, in a fat tree based
DCN, hosts in the same pod usually share the same subnet
address [21]. Thus, it is easy to determine by which layer
the two edge switches can be connected. Since the network
topology and IP address assignment are known in advance, it
is appropriate to do the calculation for all IP addresses in
advance and store the results, so that they can be quickly
obtained during path searching. Determining the connecting
layer avoids wasting bandwidth of switches at higher layers,
which will be available for future flows.
After determining the connecting layer, the scheme searches
paths for intra-cluster flows using the depth-first best-fit rule.
Specifically, starting from the source VM, the scheme searches
upstream by selecting the best-fit link to the next higher layer.
After reaching the connecting layer, the searching direction
turns downstream, similarly by selecting the best-fit link to
the next lower layer. For certain topologies, such as the fat
tree, the downstream path to a specific server is determined
after reaching the connecting layer. Since the depth-first bestfit rule does not guarantee a path on the first try, backtracking
with the next candidate or to a higher layer may be necessary.
However, the depth-first search guarantees O(|N | + |E|) time
complexity [9], where N and E are the node and edge set,
respectively. For easy understanding, Table II gives the pseudo
code description of the depth-first best-fit search.
Recall that for the VM-to-server section, the capacity
between the dummy node represents the available memory
capacity of the server and the flow demand is the memory
demand of the source VM. If the source VM is connected to
multiple servers and they have the same smallest but sufficient
capacity, preference will be given to the current hosting server
of the VM. If the servers in the cluster are homogeneous in
terms of memory and bandwidth configurations, the first VM
will stay on its current server, and thus we avoid migrating
the VM with the largest memory demand among the ones
with intra-cluster flows. Similarly, for the sever-VM section,
the link capacity between the server and the dummy node is
the server memory space, and the flow demand is the memory
demand of the destination VM.
Once the scheme finds the path for an intra-cluster flow, the
placement of the source and destination VMs are determined
as well based on the VM-to-server and server-to-VM paths.
The scheme will thus move the VMs to the selected servers,
so that additional flows of the VMs can start from the servers
instead.
After the scheme finishes processing a flow, it picks another
among the remaining ones of the same VM or the VM
with the next largest memory demand. The processing of
the newly selected flow is similar. However, since the source
and destination VMs of the flow may have been determined,
the scheme searches a path between the servers instead of
the VMs. The scheme continues the iterations until finishes
processing the VMs with intra-cluster flows. For each of
the remaining VMs with only inter-cluster flows, the scheme
decides only its hosting server based on the memory and
bandwidth demands by the best-fit criterion with priority given
to the memory demand.
B. Inter-Cluster Processing
Inter-cluster processing searches paths for flows between
different clusters, using the same depth-first best-fit rule.
After intra-cluster processing is done, all the VMs have
found their hosting servers and corresponding ToR switches.
Similar as intra-cluster processing, inter-cluster processing first
Fig. 3.
Photo of our prototype.
determines the necessary layer to connect the source and
destination ToR switches, which is solely based on the network
topology and can be calculated in advance. Then, starting
from the source ToR switch, the scheme searches upstream by
selecting the best-fit link. After reaching the connecting layer,
the scheme turns downstream by also selecting the best-fit link.
Again, backtracking may be necessary to successfully find a
path. Figure 2(d) shows the example optimization results after
applying the joint optimization scheme to the DCN in Figure
2(a), where a VM pair with the same color has a flow between
them.
VI. P ROTOTYPE I MPLEMENTATION
In this section, we describe our implementation of the
proposed scheme in a prototype using the Beacon OpenFlow
controller, HP ProCurve OpenFlow switches, VMware vCenter
server, and VMware ESXi hypervisor.
A. Hardware and Software Configuration
We have built a 4-pod and 16-host fat-tree prototype as
shown in Figure 3, to demonstrate the effectiveness and
practicality of our optimization algorithm in real networks. We
use 2 OpenFlow enabled 48-port HP ProCurve 6600 switches
running firmware version K.15.06.5008, and create 20 virtual
switches. Each virtual switch is assigned 4 ports, except that
the first core layer switch has 3 extra ports to allow connections to management nodes, including the VMware vCenter
server, Network File System (NFS) server, and DHCP server.
All switches are managed by the Beacon OpenFlow controller
version 1.0.0 with a self-developed Equinox framework bundle
that implements our optimization algorithm. Each host is
running the VMware ESXi hypervisor version 5.0.0 to host
VMs running operating system of Ubuntu Server 12.04.1 LTS
64 bit. The hosts and VMs are configured to request IP address
upon start-up through the DHCP protocol. When the controller
detects the DHCP discovery message sent by a host or a VM,
it records the host’s or the VM’s MAC address and location
based on which input port of which ToR switch received the
TABLE II
P SEUDO CODE DESCRIPTION OF DEPTH - FIRST BEST- FIT SEARCH .
DFS(G, a, b, d) { // G: network, a: source, b: destination, d: demand
1 H = necessary-layer-to-connect(G, a, b);
2 path = {};
3 u = a; // temp variable indicating current location
4 next = 1; // flag indicating search direction, 1: upstream, -1: downstream
5 return SEARCH(u, path, next);
}
SEARCH(u, path, next) {
1 path = path + u;
2 if (u = b) return true;
3 if ( layer-of(u) = H) next = −1; // reverse search direction after reaching connecting layer
4 if ( next = −1 && layer-of(u) = 1) return f alse; // failure at bottom layer
5 links = links of u to layer (layer-of(u) + next) and with available bandwidth ≥ d;
6 f ound = f alse;
7 while (links = ∅ && f ound = f alse) {
8
v = best-fit(links); links = links \ {v};
9
f ound = SEARCH(v, path, next);
10 };
11 return f ound;
}
3. Network Info.
Beacon Controller Routing Path Database
Optimizer
13. Broadcast
or Install New Flow Table
12. Packet-in
10. Power off Idle Switches
9. Power off Idle Hosts
7. RARP Packets
5. Live VM Migration
2. Flow Update
1. VM Update
8. Delete Old Flow Entries
4. Routing Paths
6. RARP Packets
Vmware vCenter
OpenFlow Switches
11. All Packets
Fig. 4.
Major steps of optimization.
message. The IP address of the host or VM is updated when
the controller detects the DHCP offer message. All hosts and
VMs are remotely managed by the VMware vCenter server
version 5.0.0 and the VM’s file system is provided by the
NFS server.
Iperf UDP flows are employed to emulate the production
traffic in data centers. The controller assigns initial routing
paths to the flows. The initial routing paths are calculated
by using the Shortest Path Routing algorithm. If there exist
multiple routing paths from the source to the destination, the
controller selects one of them randomly. For each switch on
the routing path, the controller also calculates each flow’s
input and output ports. The controller installs the flow table
entries to all the switches on the routing path by sending
them ofp_flow_mod messages with the flow’s matching
information and the calculated input and output ports.
B. Optimization
Since the Beacon controller has the view of the entire
network, we integrate the optimizer into the controller as one
of its Equinox framework bundles. The optimizer can access
all the information gathered in the initialization stage. The
optimization executes cycle by cycle and each cycle follows
the four steps described below. The major exchanged data in
one optimization cycle are shown in Figure 4.
1) Network Status Update: Before executing the optimization algorithm, the controller takes a snapshot of the current
network. The main purpose of this step is to update the
network topology, the VMs information, and the flows information that might have changed between two optimization
cycles.
For the switches and links, the controller utilizes the Link
Layer Discovery Protocol (LLDP) implemented in the original
Beacon controller. The network topology information is stored
inside the controller and will be used later in the optimization
stage describe in the next subsection. The memory and CPU
capacities of each host are fetched from the host management node, i.e., the VMware vCenter server. Specifically,
the controller sends Get-VMHost command with the host’s
IP address to the VMware vCenter through the VMware
vSphere PowerCLI interface. The VMs location and capacity
information can be gathered by using similar methods. For the
VM information, the controller sends a Get-VM command
to the VMware vCenter to update each VM’s location, CPU
demand and memory demand. For the flow information, the
controller sends ofp_stats_request messages of type
OFPST_FLOW to each virtual switch to request the flow statistics. From the statistic reply messages, each flow’s average
bandwidth demand can be estimated by the flow’s duration
and total traffic amount. The controller stores the updated
information in its database. Note that only the bandwidth of
large flows will be stored, since these flows have the major
impact on the optimization result.
2) Optimal Network Scheme Calculation: Based on the
network status snapshot, the optimizer executes the hostnetwork joint optimization algorithm described in Section V.
vCenter NFS
DHCP
Secure Channel Beacon
Controller
Core
Switches
Aggregation
Switches
ToR 301
Switches
1
VM 2
202
2
12
14
7
302
8
VM 6
Host
s
Host 1
Host 4
Switches in Spanning Tree
Fig. 5.
Switches not in Spanning Tree
Fat-tree topology of the prototype.
An optimal network scheme, including the VM’s new location
and the flow’s new routing path, is calculated. The routing
path of each large flow are stored in a HashMap dictionary
in the controller. The key of each map entry is a string that
uniquely identifies each individual flow. The value of each
map entry contains the flow table information of each switch
on the routing path, including the switch’s datapath ID, and
the input and output port of the flow. In our prototype, Iperf
UDP flows among VMs are the large flows. We concatenate
the source VM’s MAC address, the destination VM’s MAC
address and the transport layer port number of the destination
VM to form the HashMap key.
For example, one Iperf flow is from VM 2 with MAC
address 00:00:00:00:00:02 to VM 6 with MAC address
00:00:00:00:00:06 on transport layer port 5001. First
we transform the MAC address to Long type and the source
and destination MAC addresses become 2 and 6, respectively.
Then, the HashMap key should be the string of "265001".
As shown in Figure 5, we assume that the optimized locations
of VM 2 and VM 6 are on host 1 and host 4, respectively.
We also assume that the optimized routing path of this Iperf
flow is from ToR switch 301’s port 1 to port 2, then from
aggregation switch 202’s port 12 to port 14 and then from
ToR switch 302’s port 7 to port 8. Then the routing path of
this flow should be <<301, 1, 2>, <202, 12, 14>,
<302, 7, 8>>.
3) VM Location and Flow Routing Path Adjustment: In
this stage, the controller passes the optimization result to the
VMWare vCenter which will execute live VM migrations to
adjust the VM locations. Then the controller will adjust the
flow routing paths accordingly. In out prototype, the live VM
migration is implemented by the VMware vMotion migration
command Move-VM. Switches and hosts will be powered on
if they are included in the optimization result.
Upon the completion of each VM’s live migration, the VM
will broadcast several RARP messages to announce its new
location. When the controller detects such messages, it will
delete flow table entries that are calculated based on the VM’s
old location. To be specific, the controller sends two messages
to each switch to delete all flow entries that are related to
the just migrated VM. One message is to delete flow entries
whose source is the VM, while the other message is to delete
flow entries whose destination is the VM. The two messages
have the similar structure. They are both ofp_flow_mod
messages of command type OFPFC_DELETE. The only differences are in the the flow match attribute and in the
wildcards attributes. One sets the data link layer source
address as the address of the migrated VM, and sets the
wild card to OFPFW_ALLˆOFPFW_DL_SRC. The other one
sets the data link layer destination address as the address of the migrated VM, and sets the wild card to
OFPFW_ALLˆOFPFW_DL_DST.
4) Powering Off Idle Hosts, Switch Ports and Switches:
In this stage, the controller sends commands to power off
idle hosts, idle switch ports, and idle switches. A host is
considered idle if it is not hosting any active VM. A switch
port is considered idle if no traffic is currently running on the
port, and according to the optimization result, no traffic will
pass this port before the next optimization cycle. A switch
is considered idle if all of its ports are idle. For the idle
hosts, the controller sends out Stop-VMHost commands
through the VMware PowerCLI interface to power them off.
For the idle switch ports and idle switches, the controller
sends port-down commands and switch power-off commands
through the switch’s command line interface to power them
off, respectively.
The optimization cycle completes when all idle hosts and
idle switches are powered off. At this moment, when a packet
is sent to the controller to find the routing path, 1) if the packet
is a broadcast packet, the controller will ask the switches in the
spanning tree to flood this packet; 2) if the packet is a unicast
packet and belongs to a large flow with a stored routing path,
the controller will fetch the path in the HashMap database
and then install flow table entries to switches on the routing
path; 3) if the packet is a unicast packet but belongs to a flow
without a stored routing path, the controller will calculate a
random routing path based on the current topology by using
the Shortest Path Routing algorithm.
VII. S IMULATION AND E XPERIMENT R ESULTS
We have implemented the proposed joint host-network
energy optimization scheme in a simulator. In this section,
we present the numerical results from the simulations and
experiments, to evaluate our design.
A. Simulation Results
We compare the simulation results with the network-only
[14], host-only [19], and the linear programing optimization
solutions. The simulation results demonstrate that our design
outperforms the network- and host-only optimization solutions, and well approximates the ideal linear program.
1) Comparison with Linear Program: First, we compare
our joint optimization scheme with the ideal linear program,
as well as the network-only optimization solution. We use the
32-bit IBM ILOG CPLEX [1] as the linear program solver. For
network-only optimization, we pick the greedy-bin packing
Fat tree with k=16
Fat tree with k=4
Percentage of full power
100
80
60
40
20
Joint
Network−only
40
0
0
0.2
0.3
0.4
Memory and traffic load
algorithm in [14], because the topology-aware heuristic in
[14] uses different assumptions by splitting a flow among
multiple paths. We do not include host-only optimization in
this subsection, because it assumes that all the VMs have the
same memory demand.
Since the linear program is NP-complete, the simulations
can only be at small scales. We consider a fat tree with k = 4,
with the numbers of servers and switches determined as in [5].
Each link has a bandwidth capacity of 1Gbps. Each server has
a memory capacity of 8GB. The memory demand of a VM is
a random number between 500MB to 1GB, and the number of
VMs is determined by the memory load parameter. We restrict
that a VM can only migrate to a server connected by the
same aggregation layer switch, i.e. within the same pod [21].
Each VM has 2 flows in average with uniformly distributed
destinations, and the the flow bandwidth demand is determined
by the traffic load parameter. We use Equations 11 and 13
as the switch and server power functions, respectively, with
α(x) = δ(s) = 200 and β(x) = (x) = 10, and assume that
links are powered by the switches and consume no additional
energy.
In Figure 6, we let the memory load equal to the traffic load,
which changes from 0.1 to 0.9, and compare the power saving
percentages of the three solutions. We can see that our scheme
is consistently superior over network-only optimization, up to
40% better. On the other hand, our scheme well approximates
the linear program. We tried to solve the linear program
with a higher load or a larger network size, but unfortunately
CPLEX reported insufficient memory errors due to too many
constraints.
2) Comparison with Network-only Optimization: Next, we
compare the joint and network-only optimization solutions on
a fat tree with k = 16. The simulation settings are similar to
those in the previous subsection.
In Figure 7(a), we adjust the memory and traffic load, and
compare the power saving percentage of the two solutions.
Joint optimization consistently outperforms network-only optimization. While the power consumption of network-only
optimization increases quickly with the load, joint optimization
demonstrates energy proportionality. In Figure 7(b), we fix
the memory and traffic load at 0.3 and adjust the percentage
of intra-cluster traffic. Joint optimization still performs much
60
40
20
1
(a) Different memory and traffic loads.
Joint
Network−only
0.2
0.4
0.6
0.8
Percentage of intra−cluster traffic
1
(b) Different traffic patterns.
Fat tree with k=16
0.5
Comparison with linear program and network-only optimization.
0.4
0.6
0.8
Memory and traffic load
Fat tree with k=16
100
100
Percentage of full power
0.1
0.2
80
0
0
80
60
40
20
0
0
Joint
Network−only
0.2
0.4
0.6
Traffic load
0.8
80
60
40
20
0
0
1
(c) Different traffic loads.
Joint
Network−only
0.2
0.4
0.6
Memory load
0.8
1
(d) Different memory loads.
Fat tree with k=16
Fat tree with k=16
100
110
80
Routing success ratio
Linear program
Joint
Network−only
Percentage of full power
0
0
Fig. 6.
Percentage of full power
60
Percentage of full power
Percentage of full power
80
20
Fat tree with k=16
100
100
60
40
20
0
0
Joint
Network−only
0.2
0.4
0.6
0.8
Memory and traffic load
1
(e) Different power functions.
Fig. 7.
105
100
95
90
0
Joint
Network−only
0.2
0.4
0.6
0.8
Memory and traffic load
1
(f) Routing success ratios.
Comparison with network-only optimization.
better than network-only optimization. As the percentage of
intra-cluster traffic increases, we can see that the performance
of joint optimization improves, because there are more optimization opportunities for intra-cluster processing. In Figure 7(c), we fix the memory load at 0.5 and adjust the traffic
load. The power consumption of both solutions increases with
the traffic load, but joint optimization still beats network-only
optimization. In Figure 7(d), we fix the traffic load at 0.5 and
adjust the memory load, and the conclusion is similar to that
in Figure 7(c). In Figure 7(e), we use the following different
power functions for switches and servers:
# of active powers
(14)
switch power = 200 1 +
# of total ports
memory of hosted VMs
server power = 200 1 +
(15)
total available memory
Under the new power functions, joint optimization still performs better than network-only optimization. Finally, in Figure 7(f), we compare the routing success ratio of the two
solutions. Although our scheme is not designed to work under
heavy loads for a high routing success ratio, it achieves about
100% routing success under reasonably heavy loads, and so
does network-only optimization.
Fat tree with k=16
Fat tree with k=16
100
Percentage of full power
Percentage of full power
100
80
60
40
20
0
0
Joint
Host−only
0.2
0.4
0.6
0.8
Memory and traffic load
80
60
40
20
0
0
1
(a) Different memory and traffic loads.
Joint
Host−only
0.2
0.4
0.6
0.8
Percentage of intra−cluster traffic
(b) Different traffic patterns.
Fat tree with k=16
Percentage of full power
Percentage of full power
100
80
60
40
20
Joint
Host−only
0.2
0.4
0.6
Traffic load
0.8
1
80
60
40
20
Joint
Host−only
0
0
(c) Different traffic loads.
0.2
0.4
0.6
Memory load
0.8
1
(d) Different memory loads.
Fat tree with k=16
Percentage of full power
100
80
60
40
20
0
0
Joint
Host−only
0.2
0.4
0.6
0.8
Memory and traffic load
1
(e) Different power functions
Fig. 8.
B. Experimental Results
Fat tree with k=16
100
0
0
1
placement. In Figure 8(d), we fix the traffic load at 0.5
and adjust the memory load. Joint optimization is initially
worse than host-only optimization, but becomes better after
the memory load is grater than 0.5. It is interesting to note that
the performance of host-only optimization is almost linear to
the memory load. Finally, in Figure 8(e), we use the second set
of switch and server power functions, and joint optimization
still outperforms host-only optimization.
Comparison with host-only optimization.
3) Comparison with Host-only Optimization: Finally, we
compare the joint and host-only optimization solutions on
a fat tree with k = 16. Since the host-only optimization
solution considers VM placement but not flow routing, we
use a OSPF like ECMP multipath routing algorithm for it in
the simulations. Because host-only optimization assumes fixed
VM memory demands, we use a value of 0.8GB.
In Figure 8(a), we adjust the memory and traffic load, and
compare the power saving percentage of the two solutions.
Both solutions demonstrate similar and proportional power
efficiencies, with joint optimization having a slight advantage.
In Figure 8(b), we fix the memory and traffic load at 0.3 and
adjust the percentage of intra-cluster traffic. Joint optimization
is still better than network-only optimization. Similarly, the
performance of joint optimization improves with the increase
of intra-cluster traffic, because there are more optimization
opportunities. In Figure 8(c), we fix the memory load at
0.5 and adjust the traffic load. Joint optimization is initially
better than host-only optimization, but becomes worse after
the traffic load is greater than 0.6. This implies that hostonly optimization does a better job in terms of VM placement.
However, we should also notice that, host-only optimization
has higher time complexity as the cost. On the other hand,
the performance of host-only optimization is not sensitive to
the change of traffic load, because it optimizes only VM
We have conducted experiments in our prototype to evaluate
the performance of the optimization scheme. In this subsection, we first describe the experimental setup, and then present
the results to demonstrate that the optimization scheme is
effective and practical.
1) Experiment Configuration: Two experiments are conducted. In the fist experiment, the average memory and traffic
load of the prototype is set to 15%, while in the second
experiment, the load is set to 30%. VMs and network flows
are generated according to the load and the following rules.
Each VM’s memory is randomly selected between 250 MB
and 500 MB. The initial location of each VM is randomly
selected among the hosts. We adjust the number of VMs to
meet the host utilization goal of each experiment. Each VM
is configured to send out one Iperf UDP flow in average. The
normal size of the flows are randomly selected between 20
Mbps and 250 Mbps and we adjust the flow size to meet the
network utilization goal of each experiment if necessary. For
the experiment with 15% memory and traffic load, 21 VMs and
24 Iperf UDP flows are generated. For the second experiment
with 30% memory and traffic load, 42 VMs and 49 Iperf UDP
flows are generated.
Both experiments run the following steps. Initially all
switches, hosts and VMs are powered on and all flows are
started. We measure and record the current power consumption. Then, we run one full optimization cycle. After the
optimization completes, we measure the power consumption
again and compare it with the original value. Note that only
the power consumption of the hosts are measured both before
and after the optimization. This is because that the physical
switch has large power consumption overhead, and the power
consumption of each virtual switch cannot be accurately
measured. We use the Kill-A-Watt power meter model P4320
to measure the power consumption.
2) Experimental Results - Routing Path Control: In order to
verify whether the optimization is able to adjust flow’s routing
paths correctly, we study the traffic amount of the hosts to see
if they are as same as expected. Due to space limitations, we
only present the result of Host 4 in this paper. The results of
other hosts follow the similar pattern and lead to the same
conclusion.
Table III(a) and (b) give the detailed configuration of the
flows and traffic amount of Host 4, before and after the
optimization, respectively. The VMs with bold name are the
ones hosted by Host 4. Thus, before the optimization, only
VM 7 is hosted by Host 4; after the optimization, 3 additional
TABLE III
F LOW CONFIGURATION AND TRAFFIC AMOUNT OF H OST 4
Flow Direction
VM 4 → VM 7
VM 7 → VM 19
Total
Flow Bandwidth (Mbps)
83.7
90.1
173.8
Outgoing Traffic Amount of Host 4 (Mbps)
90.1
90.1
Incoming Traffic Amount of Host 5 (Mbps)
83.7
83.7
(a) Before Optimization
Flow Direction
VM 4 → VM 7
VM 4 → VM 17
VM 7 → VM 19
VM 9 → VM 3
VM 11 → VM 9
VM 11 → VM 20
VM 19 → VM 3
Total
Flow Bandwidth (Mbps)
83.7
27.8
90.1
26.8
22.7
56.0
119.1
396.2
Outgoing Traffic Amount of Host 4 (Mbps)
27.8
26.8
56.0
119.1
229.7
Incoming Traffic Amount of Host 5 (Mbps)
0
(b) After Optimization
#
(
(%%
'%%
&*%
&%%
$(
$
%
&%% '%% (%% )%% *%% +%% ,%% -%% .%% &%%% &&%% &'%% &(%% &)%% &*%%
!"
Fig. 9.
Measured incoming and outgoing traffic of Host 4.
VMs are hosted by Host 4, including VM 4, VM 11, and VM
19. If either a flow’s source or destination VM is on Host
4, this flow accounts Host 4’s network traffic. The traffic’s
direction and amount is the same as the flow’s direction and
bandwidth, respectively. For example, after the optimization,
the flow from VM 4 to VM 17 accounts 27.8 Mbps of Host 4’s
total outgoing traffic. If both the source and destination VMs
of a flow are on Host 4, the flow does not account any of Host
4’s traffic. One example is the flow from VM 7 to VM 19 after
the optimization. The total outgoing traffic amount and total
incoming traffic amount of Host 4 should be the summation
of each flow’s outgoing traffic amount and the summation of
each flow’s incoming traffic amount, respectively.
Figure 9 shows the measured total outgoing and the measured total incoming traffic of Host 4 before and after the
optimization. We can find that, before the optimization and the
VM migrations, the amount of outgoing traffic and the amount
of incoming traffic of Host 4 are the same as the calculated
amount shown in Table III(a). During the optimization, Host
4’s incoming traffic amount changes dramatically. This is
due to the VM migration traffics that has Host 4 as the
destination. After the optimization, the total outgoing traffic
of Host 4 stabilizes at around 225 Mbps which has less than
2% difference as the calculated amount shown in Table III(b).
The incoming traffic amount of Host 4 after the optimization
drops to zero which is the same as calculated in Table III(b).
In summary, by comparing the measured traffic amount with
#(
#
!%
"(
"(
"
"##
*%
'
"
!
'
'
'*%
%
(
(
"
(
(
$'
"'
$
"
!
$
"'
!'
#! !"
(*%
)%%
'
'
(a) Memory and traffic load = 15%. (b) Memory and traffic load = 30%.
Fig. 10.
Power consumption comparison before and after optimization.
the calculated traffic amount, we show that the optimization
can adjust the flow’s routing paths correctly.
3) Experimental Results - Power Consumption Reduction:
Figure 10(a) and 10(b) illustrates the comparison of the power
consumptions before and after the optimization when system
load is equal to 15% and 30%, respectively. Both figures
show that the power consumption after the optimization is
lower than before the optimization. Specifically, Figure 10(a)
shows that when system load is equal to 15%, the total power
consumption drops from 1139W to 466W or from 100%
to 41%. In other words, the optimization saves 59% of the
original power consumption. Figure 10(b) shows that when
system load is equal to 30%, the total power consumption
drops from 1228W to 742W or from 100% to 60%. In other
words, the optimization saves 40% of the original power
consumption. It is worth noting that the optimization yields
larger reduction of the power consumption when system load
is lighter. This is because that, when the system load is lighter,
VMs will be consolidated into fewer number of hosts and
thus more idle hosts can be powered off to further reduce the
power consumption. The experiment results have demonstrated
that our joint host-network optimization is an effective and
practical method to improve the data center’s energy efficiency.
VIII. D ISCUSSIONS
In this section, we discuss some practical issues in the joint
host-network optimization implementation.
A. Broadcast in OpenFlow Networks
Traditional switches flood broadcast packets to certain ports,
while other ports are blocked by the spanning tree protocol
such that no loop exists in the network. But since the spanning
tree protocol may conflict with the controller, it is disabled on
OpenFlow switches by default. Thus it is challenging to enable
broadcast in networks that have loops. To solve such problem,
we construct a spanning tree and put it in the controller instead
of on the switches. When the controller detects broadcast
packets, it asks only the switches in the spanning tree to flood
the packets.
B. Energy Consumed by VM Migration
It should be noted that while we try to reduce energy consumption by migrating VMs, the operation of VM migration
itself also consumes energy, but it is fortunately a one-time
overhead. Since VM migration is essentially to copy the VM
memory image between servers, its energy consumption can
be estimated by by the size of the VM memory image.
C. Safety Margins
While our design uses the best-fit criterion to maximize
flow consolidation, it is necessary to leave certain safety
margins for redundancy and traffic burst. This can be done
by leaving a certain percentage of the link capacity untouched
in the optimization process, and it will be our future work to
determine a reasonable percentage value.
IX. C ONCLUSIONS
The data center network (DCN) has become a major fraction
of the energy consumption of a data center. In this paper, we
propose a joint host-network optimization scheme to improve
the energy efficiency of DCNs. First, we present a unified
representation method to convert the virtual machine placement problem to a routing problem, so that a single solution
can apply to both types of optimization. Next, we describe
a parallelization approach that divides the DCN into clusters
based on subnet IP addresses, and processes the clusters in parallel for fast completion. Further, we propose a fast topology
oriented mutipath routing algorithm that can quickly find paths
by using depth-first search to traverse between the hierarchical
layers, and maximize energy conservation by using the best-fit
criterion to consolidate flows. Finally, we build an OpenFlow
based prototype, and have conducted extensive simulations
and experiments to evaluate the performance of our design.
The simulation and experiment results demonstrate that our
design is effective and practical, and it is also superior over
existing host- or network-only optimization solutions, and well
approximates the ideal linear program.
R EFERENCES
[1] “IBM ILOG CPLEX Optimizer,” http://www-01.ibm.com/software/
integration/optimization/cplex-optimizer/.
[2] “U.S. Environmental Protection Agencys Data Center Report to
Congress,”
http://www.energystar.gov/ia/partners/prod development/
downloads/EPA Datacenter Report Congress Final1.pdf.
[3] “Who Has the Most Web Servers?” http://www.datacenterknowledge.
com/archives/2009/10/13/facebook-now-has-30000-servers/.
[4] D. Abts, M. R. Marty, P. M. Wells, P. Klausler, and H. Liu, “Energy
proportional datacenter networks,” in ACM ISCA, Saint-Malo, France,
Jun. 2010.
[5] M. Al-Fares, A. Loukissas, and A. Vahdat, “A scalable, commodity data
center network architecture,” in ACM SIGCOMM, Seattle, WA, Aug.
2008.
[6] M. Alizadeh, A. Greenberg, D. A. Maltz, J. Padhye, P. Patel, B. Prabhakar, S. Sengupta, and M. Sridharan, “Data Center TCP (DCTCP),” in
ACM SIGCOMM, New Delhi, India, Aug. 2010.
[7] K. Chen, C. Guo, H. Wu, J. Yuan, Z. Feng, Y. Chen, S. Lu, and W. Wu,
“Generic and automatic address configuration for data center networks,”
in ACM SIGCOMM, New Delhi, India, Aug. 2010.
[8] C. Clark, K. Fraser, S. Hand, J. G. Hansen, E. Jul, C. Limpach, I. Pratt,
and A. Warfield, “Live migration of virtual machines,” in USENIX NSDI,
Berkeley, CA, Apr. 2005.
[9] T. H. Cormen, C. E. Leiserson, R. L. Rivest, and C. Stein, Introduction
to Algorithms, 3rd ed. MIT Press, 2009.
[10] W. Fisher, M. Suchara, and J. Rexford, “Greening backbone networks:
reducing energy consumption by shutting off cables in bundled links,”
in ACM SIGCOMM Workshop on Green Networking, New Delhi, India,
Aug. 2010.
[11] A. Greenberg, N. Jain, S. Kandula, C. Kim, P. Lahiri, D. Maltz, P. Patel,
and S. Sengupta, “Vl2: a scalable and flexible data center network,” in
ACM SIGCOMM, Barcelona, Spain, Aug. 2009.
[12] A. Greenberg, P. Lahiri, D. A. Maltz, P. Patel, and S. Sengupta,
“Towards a next generation data center architecture: scalability and
commoditization,” in ACM SIGCOMM PRESTO, Seattle, WA, Aug.
2008.
[13] D. Grunwald, P. Levis, K. I. Farkas, C. B. Morrey, III, and M. Neufeld,
“Policies for dynamic clock scheduling,” in USENIX OSDI, San Diego,
CA, Oct. 2000.
[14] B. Heller, S. Seetharaman, P. Mahadevan, Y. Yiakoumis, P. Sharma,
S. Banerjee, and N. Mckeown, “Elastictree: saving energy in data center
networks,” in USENIX NSDI, San Josa, CA, Apr. 2010.
[15] J. Kurose and K. Ross, Computer networking: a top-down approach (4th
Edition), 4th ed. Addison Wesley, 2007.
[16] P. Mahadevan, S. Banerjee, and P. Sharma, “Energy proportionality
of an enterprise network,” in ACM SIGCOMM Workshop on Green
Networking, New Delhi, India, Aug. 2010.
[17] P. Mahadevan, A. Shah, and C. Bash, “Reducing lifecycle energy use
of network switches,” in ISSST, 2010.
[18] D. Meisner, B. T. Gold, and T. F. Wenisch, “Powernap: eliminating
server idle power,” in ASPLOS, Washington, DC, Mar. 2009.
[19] X. Meng, V. Pappas, and L. Zhang, “Improving the scalability of data
center networks with traffic-aware virtual machine placement,” in IEEE
INFOCOM, San Diego, CA, Mar. 2010.
[20] J. Mudigonda and P. Yalagandula, “Spain: Cots data-center ethernet for
multipathing over arbitrary topologies,” in USENIX NSDI, San Josa, CA,
Apr. 2010.
[21] R. N. Mysore, A. Pamboris, N. Farrington, N. Huang, P. Miri, S. Radhakrishnan, V. Subramanya, and A. Vahdat, “Portland: a scalable
fault-tolerant layer2 data center network fabric,” in ACM SIGCOMM,
Barcelona, Spain, Aug. 2009.
[22] C. Patel, C. Bash, R. Sharma, M. Beitelmam, and R. Friedrich, “Smart
cooling of data centers,” in InterPack, Maui, HI, Jul. 2003.
[23] S. Pelley, D. Meisner, T. F. Wenish, and J. W. VanGilder, “Understanding
and abstracting total data center power,” in ISCA 2009: Workshop on
Energy Efficient Design (WEED), Jun. 2009.
[24] G. Schaffrath, S. Schmid, and A. Feldmann, “Optimizing long-lived
cloudnets with migrations,” in Proceedings of 5th IEEE/ACM International Conference on Utility and Cloud Computing (UCC), 2012.
[25] Y. Shang, D. Li, and M. Xu, “Energy-aware routing in data center
network,” in ACM SIGCOMM Workshop on Green Networking, New
Delhi, India, Aug. 2010.
[26] M. Wang, X. Meng, and L. Zhang, “Consolidating virtual machines with
dynamic bandwidth demand in data centers,” in INFOCOM, Shanghai,
China, Apr. 2011.
[27] M. Zhang, C. Yi, B. Liu, and B. Zhang, “Greente: Power-aware traffic
engineering,” in IEEE ICNP, Koyoto, Japan, Oct. 2010.