ORIGINAL RANGE KUDOS REFRESHING INNOVATION IN SHOWERS 1400/1500/1700 BI-SLIDER Installation Instructions Please read these instructions before installing, as incorrect fitting will invalidate the guarantee. Carry out each stage before moving onto the next. Do not dispose of packaging, no claims for damaged or missing parts will be accepted if the packaging has been disposed of. If you are unsure about these instructions please contact Kudos Shower Products: Customer Service Helpline: 01539 564040 KEY STAGES TOOLS REQUIRED ? Flat-Headed Screwdriver ? Pozi-Drive Screwdriver ? Spirit Level ? Tape Measure ? Silicone Sealant ? 4mm & 2.5mm Allen Key (Supplied) ? Electric Drill ? 7mm Drill Bit (Masonry) ? Decide handing of the door ? Assemble the frame work ? Remove the clip -in extrusions ? Position and level the frame work in situ ? Drill walls and fix frame work ? Fit the fixed panel ? Fit the sliding door ? Silicone seal the enclosure IMPORTANT Check appearance of shower enclosure - any defects must be Prior to tiling, any gap or crevice between the rim of the tray and reported to Kudos Shower Products before assembly/installation the wall must be filled with silicone sealant flush with the rim of the Claims for imperfections will only be accepted prior to tray - see Fig.1 assembly/installation Waterproof the walls using ceramic tiles/shower panels etc. before installation of the shower enclosure Any claims made under the terms of the Lifetime Guarantee must be reported to Kudos within 21 days of the fault occurring Fully seal between tiles/shower panels and the tray BEFORE Check the enclosure adjustment sizes are suitable for your installing the enclosure - see Fig.2 installation Use care when drilling into the walls to avoid hidden pipes or electric cables Ensure the top of shower tray is level in all directions Once the tray is installed but before the tiles are fitted any crevice between the tray and the walls must be filled with silicone sealant flush with the top of the tray. SILICONE SEALANT FIG.1 FIG.2 Once the walls have been tiled but before the enclosure is installed, the tiles must be silicone sealed to the tray all of the way around in one continuous bead. CLEANING GENERAL - for the frame work and fixings use only warm soapy water and damp cloth/ sponge on a regular basis. After cleaning please rinse with clean water to remove any residue. Do not use abrasive scouring powders, chemicals or aerosol cleaners - these may result in damage to the surfaces, in particular, the plated component parts. See instruction below for glass cleaning advice. LIFESHIELD Your Kudos Product is pre-treated with Life Shield on the inside surfaces only. While this makes cleaning the glass a lot easier and helps prevent the build up of harmful lime-scale and soap deposits the glass still needs to be maintained on a regular basis. We recommend the use of a detergent and aroma free glass cleaner (A 50/50 mix of Vinegar and Water works well!!) Strong detergents and abrasives can damage the coating. DO NOT use abrasive cleaners or abrasive scrubbing equipment for cleaning!! DO use a squeegee to remove remaining droplets of water from glass after showering, any build up of residue can be removed easily using an appropriate cleaner and agitation from soft cleaning equipment THESE INSTRUCTIONS TO BE LEFT WITH THE CUSTOMER BEFORE BEGINNING THIS INSTALLATION PLEASE: 1 ? Ensure you have read and understood these instructions ? Check that the tray has been silicone sealed as instructed ? Check all of the frame work and glass for visible signs of damage ? Decide on the handing of the shower enclosure ? Check that the enclosure is of the correct size to suit the installation ? Be sure that you have all the required tools to complete the job Cut out each end of the end wraps where shown. These will help with the assembly of the enclosure. If you have help then these may not be necessary. 2 Remove the fixed panel patches from the fixed glass (glass without handle) by removing the allen key screws. Keep the inner patch covers safe. Slide x1 Stop Block into each rail as shown, and then x2 Fixed Panel Patches into each rail as shown. You do not need to secure these fixings into the rail at this stage. 3 X1 KUDO S Stop block from installation pack If you need to report a fault you must do so BEFORE installation. X2 If there is anything you are not sure about then please call the Kudos Helpline 4 Fixed panel patch from fixed glass To help with assembly insert the rails into end wraps as shown. The rails are handed, the fixed panel end can be identified by the pre drilled hole at the end. These instructions show a Right Hand Entry TOP Identify both wall posts. The wall post with the plastic flipper seal as shown will be the opening side of the enclosure, the one without the seal will be the fixed panel side. Please ensure that the wall post without the flipper seal is to go to the end of the rails with the pre drilled hole as shown in stage 4. 5 Pre drilled hole viewed from inside PLASTIC SEAL This stage is best carried out against a wall. Start off with the bottom rail and ensure that the outer face of the rail is facing away from the wall. BOTTOM FIXED PANEL SIDE Secure the wall posts to the rails using the X8 No.6x30PH screws from the screw Assembly Pack. Please ensure that each screw locates into the relevant screw port in the rail as shown. We recommend that you start with the top rail. 6 7 OPEN SIDE Insert the height adjustment blocks into the base of the wall posts as shown. You will need to lift the wall post slightly to allow space to fit the height adjustment block. 1 2 3 SCREW PORTS Ensure that the screws are fully tightened Insert spiral cam as shown in the image Slide the main height adjuster block into the base of the wall post, it will “Click” when engaged When fitted the height adjuster block should be flush with the base of the wall post 8 Carefully tear off the side wraps and discard. Then remove the extrusions as shown below. Apply pressure to the indicated face of the extrusion Release the inner/outer edge of the extrusion over its entire length Lift the extrusion out and away from the wall posts 9 Position onto the tray, Expand frame equally into the opening using the x3 lateral adjustments on each wall post so that the frame wedges into place. Level the bottom rail if required using the height adjustment. Level the frame work to the wall and mark the screw fixing positions. TIP Ensure the framework is level vertically and horizontally using a spirit level Screw fixing position (x3 per wall post) Lateral Adjustment (Anti-Clockwise to expand) To mark the screw fixing positions dip the end of a drill bit into some shoe polish TIP Height adjustment (Level bottom rail) IF USING A SIDE PANEL PLEASE REFER TO SIDE PANEL INSTRUCTIONS AFTER THIS STAGE 10 CAREFULLY REMOVE THE FRAME FROM THE TRAY 1 Once the enclosure is removed drill holes into the walls using a 7mm Drill Bit, CHECK FOR PIPES AND CABLES 2 Insert wall plugs or fixings suitable for your walls. Then secure frame to wall using X6 No.8x30 PH screws supplied 3 Level door frame using adjustments shown in stage 9, ensure the wall posts are straight and not bowed out in the middle from over tightening the middle adjustment screws. Carefully lift fixed glass panel into the enclosure and secure to fixed panel patches. Make sure you have the 4mm Allen key & inner patch covers to hand. Ensure the rigid seal is to the wall post with the Life Shield treated surface to the inside. 12 Place fixed glass onto the bottom patches and hold firm with your foot. Push the top of glass onto locating holes in top patches and re-fit the inner patch covers. Repeat for the bottom patches. Measure the centres of the holes in the fixed panel, once done position the patch closest to the wall post 200mm away from the post, then space the second patch the equal distance from this to the fixed panel holes (measure to the centre of the fixed panel patches). Repeat for the patches at the bottom. 11 IMPORTANT Before fitting the fixed panel glass, ensure that the Shim Strip is placed between the bottom rail and the tray half way along it’s length, this will support the weight of the glass and prevent the bottom rail bowing m 200m e to tanc le o al dis Equ panel h fixed es r cent This rigid seal on the edge of the fixed panel glass is to go to the wall post with the lip to the inside SHIM STRIP 13 1 Re-fit the extrusions by reversing the procedure in stage “8" Slide fixed panel back to the fixed side wall post, ensure lip of seal fully locates into the groove in the extrusion. Once secured ensure all allen screws are fully tightened. Slide the fixed panel up to the wall post, slightly loosening the allen key screws may make this easier 2 Ensure the lip on the rigid seal locates into the extrusion over it’s full length Seal 3 Using X4 6x20PH screws secure the patches into the pre drilled holes, if the holes do not line up loosen the allen key screw and move patch on glass to align, re-tighten all allen key screws. Fix Insert glazing seals as shown, around the outside of the fixed panel. Also at this stage fit the inner fixed patch covers as shown, you will not be able to fit all of these once the door glass is installed. 14 Remove the wheel patch fixings from the door glass using the 4mm allen key supplied. Sit these patch fittings into TOP rail upside down then turn the right way around to lock them into the rail. 15 Bottom & Top Carefully feed the glass into the unit and match up the top holes with the wheel patches. Screw the inner cover back on. Ensure the shoulders of the patch fittings are tight against the top edge of the glass. If the handing of the door glass is being changed then you will need to remove the quick release patches and splash seal and ensure they are to the bottom of the door with the levers pointing towards each other. 16 Keep inner fixings to hand when positioning the glass door Seal shown shorter for clarity If seals feel tight, then TIP wetting in clean water Support weight of glass on your foot when securing to the top wheel patches TIP will help. Ensure you do not stretch the seals. Trim to correct length. Adjust the hanging of the door so that the closing edge of the glass meets the closing seal evenly over it’s entire height. Gain access to screw “A” by removing the top patch cover. 17 PLEASE ENSURE THAT AFTER ADJUSTMENT ALL SCREWS ARE FULLY TIGHTENED TO RAISE THIS SIDE OF DOOR USE SCREW ‘A’ TOP FIT COVER CAPS, to all patch fittings and each wallpost Secure wallpost cover caps using No.4 x 10mm long screws provided. 18 1 FIT VERTICAL DOOR seal onto the opposite edge of the sliding door to the handle. Position stop blocks to prevent the handle of sliding door impacting on edge of fixed panel, then tighten allen key grub screws with 2.5mm Allen Key. 19 TO RAISE THIS SIDE OF DOOR USE SCREW ‘A’ A A B B DOOR FIXED TO LOWER THIS SIDE OF DOOR USE SCREW ‘B’ A B SLIDING DOOR VIEW FROM INSIDE 2 TO LOWER THIS SIDE OF DOOR USE SCREW ‘B’ Roller bearing adjustment- using screwdriver, loosen screw (do not remove), reposition in slot and re-tighten. Patch fitting adjustment- using allen key, loosen screw (do not remove), lower glass and re-tighten. Silicone seal the wallposts. Both wallposts should be sealed vertically to the tiled / panelled walls on the Outside & Inside of the enclosure. 20 Silicone seal the enclosure to the tray on the outside only You should also seal the joint as shown. 21 IMPORTANT!! Do not seal to the tray on the inside, this will prevent drainage of the frame work and will cause leakage problems Seal joint at both ends of the bottom rail ? Check the running of the door, vasaline can be applied to the bottom track to improve the sliding action Check that the shim strip has ? been installed under the bottom rail ? Check that all the screws and fittings are fully tightened ? Ensure that the quick release levers are to the bottom of the door ? Leave for 24hrs before use to allow silicone sealant to cure ">
Advertisement
Key features
- Sliding door
- Multiple adjustment points
- Easy installation
- Secure door
- Easy cleaning
Frequently asked questions
You can adjust the height of the shower door by loosening the screws labeled 'A' and 'B' on the wall posts.
You will need a flat-headed screwdriver, a Pozi-drive screwdriver, a spirit level, a tape measure, silicone sealant, a 4mm and 2.5mm allen key, an electric drill, and a 7mm drill bit for masonry.
The silicone sealant needs to cure for 24 hours before using the shower enclosure.