GL18
Project:
Location:
Site & Area
Cat.No:
Type:
Quantity:
Gullwing LED
Notes:
Philips Gardco Gullwing LED luminaires combine LED performance excellence
and advanced Gardco LED thermal management technology with the distinct
Gullwing style to provide outdoor area lighting that is both energy efficient and
aesthetically pleasing.
Large, GL18
Ordering guide
Prefix
GL18
Example: GL18-APD-1-4-80LA-4853-NW-120-BRP-LF
Controls
Mounting
4
Optics
5
4
GL18-DIM
210LA-641A
105LA-4870
48 LEDs, 700mA
CW
Cool White
160LA-481A
5700K,
480
70 min. CRI
3@90°
3
Type 3
UNV
3-90
Type 3@90°
180LA-6490
WW
(120-277V)
3@120°
3@120°
Warm White
HVU
3000K,
4
4@90
3-270
(347-480V)
W
Wall Mount,
Recessed
J-Box
4
Type 4
GL18-DIM
2
18” Gullwing LED with 0-10V Dimming
2 @ 180°
GL18-APD1
2@90
18” Gullwing LED with Automatic
2 @ 90°
3
GL18-MRI2,4
18” Gullwing LED with Motion Response at
50% Low (luminaire mounted sensor uses
remote pod mounted to arm)
GL18-APD-MRI2,4
18” Gullwing LED with APD with Motion
Response Override (luminaire mounted
PCR7
2-270
Type 2@270°
Luminaire
Constant Wattage
18” Gullwing LED with APD with Motion
Response Override (pole mounted sensor)
Options
NP
4000K,
Type 2
GL18-APD-MRO2,3,4
Finish
UNV
80LA-4853
2
Single
18” Gullwing LED with Motion Response 50% Low (pole mounted sensor)
Voltage
2-90
Type 2@90°
1
GL18-MR50
NW
NW
Neutral White
Gullwing Standard Luminaire
2,3,4
LED Color
50LA-4835
48 LEDs, 350mA
GL18
18” Gullwing LED
Profile Dimming
LED Wattage
WS
Wall Mount,
Surface
Conduit
sensor uses remote pod mounted to arm)
Type 3@270°
4-90
Type 4@90°
4-270
Type 4@270°
5
Type 5
48 LEDs, 530mA
48 LEDs, 1A
64 LEDs, 900mA
210LA-641A
64 LEDs, 1A
70 min. CRI
208
BLP
Black Paint
LF4 In-Line/In-Pole Fusing
(supply specific voltage)
240
WP
PC4,6,9
277
White Paint
347
BRP
Bronze
Paint
PCR54,6,8,9 Photocell Receptacle
NP
Natural
PCR74,7,8,9 Photocell Receptacle
120
70 min. CRI
200LA-9670
96 LEDs, 700mA
Aluminum
Paint
265LA-9690
96 LEDs, 900 mA
310LA-961A
only with 2 dimming and
2 auxiliary connections
HS
External Houseside Shield
IS
Internal Houseside Shield
(types 2, 3, 4 only)
Color
CLR5
Clear Glass Lens
(reduces performance
RPA1
3” Round Pole Adapter
SC
Special
96 LEDs, 1A
GL18-RK
only with 2 dimming
connections
OC
Optional
Specify
optional color
or RAL
ex: OC-LGP
or
OC-RAL7024.
230LA-9680
96 LEDs, 800mA
Photocontrol and
Receptacle
(Includes PCR5)
18” Gullwing LED Retrofit Kit
Color
Specify. Must
Wireless Controls
supply color
LLC2 1,4,9 #2 lens for 8-15'
mounting heights
chip. Requires
factory quote.
LLC3 1,4,9 #3 lens for 15-25' mounting
heights
Required for 3" O.D. round or
tapered round poles where top
O.D. is less than 4".
RPA2
4” and 5” Round Pole
Adapter Required for 4"- 5"
O.D. round poles.
MF
Mast Arm Fitter - Mounts
to a 2-3/8" O.D. mast arm.
TR110
Single Transition
TR210
Twin Transition
PTF211 Pole Top Fitter 2 3/8” - 3” Dia. Tenon
LLC4 1,4,9 #4 lens for 25-40'
mounting heights
PTF311 Pole Top Fitter 3” - 3 1/2” Dia. Tenon
PTF411 Pole Top Fitter 3 1/2” - 4” Dia. Tenon
SQPTF 12Square Pole Top
Fitter
5. Luminaire door frame and optic assembly provided
standard without glass lens. Specify CLR option for
clear glass lens.
1. Available 120-277V only.
2. Available 120 or 277V only.
3. MR50 and APD-MRO luminaires require one motion sensor
per pole, ordered separately. See page 2 for Accessories.
4. Not available with Retrofit Kits (GL18-RK).
GL18 04/15 page 1 of 8
6. Works with 3-pin or 5-pin NEMA photocell/dimming
device.
7. Works with 3-pin or 5-pin NEMA photocell/dimming device
and auxiliary connections are not connected (for future
use only).
8. If ordered with DIM, APD, MRI, MR50, APD-MRI, APDMRO, dimming will not be connected to NEMA receptacle.
9. LLC2/LLC3/LLC4/LLP wireless controls not configurable
with PC/PCR5/PCR7 Options. See pages 6-7 for more info.
10. Mounts to a 2-3/8" Top Tenon. Specify a round pole
with a 4.50" O.D. for a smooth transition.
11. Not available in 120° mounting configurations.
12. Requires a 2-3/8"O.D. x 4" tenon or a 2.4" round pole top
O.D. Specify Drilling (1, 2, 2@90, 3 or 4 only.)
District 2 North Parking Lot
Lighting Improvements
Aurora, CO
Not for construction,
demonstrates design intent
65%
Submit-
Date:
03-21-16
Note: This Luminaire Cut is for information only. Refer to Specifications for all Catalogue Numbers, Lamps, Finishes, Accessories, Etc.
TYPE:
PL
(1-3)
GL18 Gullwing LED Site and Area Luminaire, Large
Accessories - Ordering guide (Must be ordered separately)
GL18 Drill Template
Motion Response Accessories
MS-P13
0.39”
(0.99 cm)
120V or 277V Input - Pedestrian Motion
Sensor for GL18-MR (Motion Response)
or GL18-APD-MRO (Automatic Profile
Dimming with Motion Response Override)
2.25”
(5.72 cm)
MS-A-120V14 120V input - Motion Sensor for MR50 or
0.875”
(2.22 cm)
MRO (pole mount only)
2.17”
(5.51 cm)
MS-A-277V14 277V input - Motion Sensor for MR50 or
MRO (pole mount only)
3.84”
(9.75 cm)
Note: Motion Sensors are ordered separately, with one (1) motion
sensor required per pole location for GL18-MR50 or GL18-APDMRO luminaires. See Luminare Configuration Information on
pages 4-5 for more details. Pedestrian sensor color is white. Area
motion sensor color is Arctic White.
13. Available 120-277V only.
14. Available 120 or 277V only.
Dimensions and EPA
18"
31.6"
A
45.72 cm
80.264 cm
C
6.6"
16.764 cm
11.5"
29.21 cm
EPA Data
1
1.2 ft2
2
2.4 ft2
3-4
3.2 ft2
.12 m
.24 m
.30 m2
2
2
Approximate Weight (Single
Luminaire): 40 lbs / 18.144 kg
GL18-RK LED Retrofit Kit
Existing
EXISTINGUpper
UPPER
Housing
HOUSING
Note: Removal of all components of existing G18
Gullwing luminaires, except the upper housing, is
required to perform a retrofit.
GL18-RK includes all necessary retrofit components.
LED
LEDDoor
DOOR
ASSEMBLY
Assembly
GL18
04/15
Note: TGIC polyester powdercoat will fade somewhat in exterior
environments over time. Once the retrofit kit is installed, there is a
possibility that the upper housing may have faded to a point where
there is a noticeable paint difference between the upper housing
(existing) and the new retrofit kit door frame.
page 2 of 8
District 2 North Parking Lot
Lighting Improvements
Aurora, CO
Not for construction,
demonstrates design intent
65%
Submit-
Date:
03-21-16
Note: This Luminaire Cut is for information only. Refer to Specifications for all Catalogue Numbers, Lamps, Finishes, Accessories, Etc.
TYPE:
PL
(1-3)
GL18 Gullwing LED Site and Area Luminaire, Large
Technical Data
Type 2
Type 3
Ordering Code
Total
LEDs
LED
Current
(mA)
Average
System
Watts 16
Color
Temp.
Lumen
Output 16,17
Efficacy
(LPW)
BUG
Rating
Lumen
Output 1, 2
Efficacy
(LPW)
BUG
Rating
50LA-4835
48
350
50
4000K
6207
124
B2-U0-G1
5710
109
B1-U0-G2
B2-U0-G2
80LA-4853
48
530
80
4000K
8949
112
B2-U0-G1
8230
104
105LA-4870
48
700
105
4000K
11,352
108
B3-U0-G2
10,446
98
B2-U0-G2
160LA-481A
48
1050
160
4000K
15,403
96
B3-U0-G2
14,159
88
B2-U0-G3
180LA-6490
64
900
180
4000K
17,788
99
B3-U0-G2
16,689
94
B3-U0-G3
210LA-641A
64
1050
208
4000K
19,964
96
B3-U0-G2
18,718
89
B3-U0-G3
200LA-9670
96
700
200
4000K
22,175
111
B3-U0-G2
20,296
100
B3-U0-G3
230LA-9680
96
800
230
4000K
24,492
106
B3-U0-G2
22,430
96
B3-U0-G4
265LA-9690
96
900
265
4000K
26,809
101
B4-U0-G2
24,543
93
B3-U0-G4
310LA-961A
96
1050
309
4000K
29,331
95
B4-U0-G3
26,843
87
B3-U0-G4
Ordering Code
Total
LEDs
LED
Current
(mA)
Average
System
Watts 16
Color
Temp.
Lumen
Output16,17
Efficacy
(LPW)
BUG
Rating
Lumen
Output 1, 2
Efficacy
(LPW)
Type 4
Type 5
BUG
Rating
50LA-4835
48
350
50
4000K
5891
118
B1-U0-G2
6198
124
B3-U0-G1
80LA-4853
48
530
80
4000K
8494
106
B1-U0-G2
8935
112
B3-U0-G2
105LA-4870
48
700
105
4000K
10,774
103
B2-U0-G2
11,335
108
B4-U0-G2
160LA-481A
48
1050
160
4000K
14,619
91
B2-U0-G3
15,379
97
B4-U0-G2
180LA-6490
64
900
180
4000K
16,780
93
B2-U0-G3
17,967
100
B4-U0-G2
210LA-641A
64
1050
208
4000K
18,832
91
B3-U0-G3
20,165
94
B4-U0-G2
200LA-9670
96
700
200
4000K
20,700
103
B3-U0-G4
22,300
112
B5-U0-G3
230LA-9680
96
800
230
4000K
22,863
99
B3-U0-G4
24,630
107
B5-U0-G3
265LA-9690
96
900
265
4000K
25,026
94
B3-U0-G4
26,961
102
B5-U0-G3
310LA-961A
96
1050
309
4000K
27,380
89
B3-U0-G4
29,497
93
B5-U0-G3
16. Wattage may vary by +/- 8% due to LED manufacturer forward volt specification and ambient temperature. Wattage shown is average for 120V through 277V input. Actual wattage may vary by an additional +/- 10%
due to actual input voltage.
17. Values shown are for luminaires without the HS external shield option. Tests are in process for luminaires with the HS option and WW luminaires. Contact outdoorlighting.applications@philips.com if approximate
estimates are required for design purposes.
Luminaire Configuration Information
GL18
GL18-APD Dimming Profile:
Philips Gardco Gullwing LED standard
luminaire providing constant wattage and
constant light output when power to the
luminaire is energized.
Power On
GL18-DIM
Philips Gardco Gullwing LED luminaire
provided with 0 -10V dimming for connection
to a control system provided by Philips or by
others.
GL18-APD
Philips Gardco Gullwing LED luminaire with
Automatic Profile Dimming. Luminaire is
provided with a programmable LED Driver,
programmed to go to 50% power, 50%
light output two (2) hours prior to night
time mid-point and remain at 50% for six
(6) hours after night time mid-point. Midpoint is continuously recalculated by the
programmable LED Driver based on the
average mid-point of the last two full night
cycles. Short duration cycles, and power
interruptions are ignored and do not affect the
determination of mid-point.
GL18
04/15
2 hours
6 hours
50%
50%
100%
100%
Mid Point
Power Off
The GL18-APD offers many of the advantages
of a sophisticated control system, including
an average energy savings of at least 33%
versus constant wattage, constant light output
systems, without the need for a control system.
remains on high until no motion is detected
for the motion sensor duration period, after
which the luminaire returns to low. Duration
period is factory set at 15 minutes, and is field
adjustable from 5 minutes up to 15 minutes.
This configuration is not available for use with
wall mounted luminaires.
GL18-MR50 is available in 120V through 277V
input only to the luminaire. Motion sensors
require single voltage 120V or 277V input.
GL18-MR50 (Pole Mounted Sensor)
Philips Gardco Gullwing LED luminaire with
motion response, providing a 50% power
reduction on low and a commensurate
reduction in light output. The power and light
output reduction is accomplished utilizing the
Philips DynaDimmer module, programmed
for a constant 50% power. Power supplied by
the motion sensor connected to the override
line on the DynaDimmer takes the luminaire
to high setting, 100% power and light output,
when motion is detected. The luminaire
page 3 of 8
District 2 North Parking Lot
Lighting Improvements
Aurora, CO
Not for construction,
demonstrates design intent
65%
Submit-
Date:
03-21-16
Note: This Luminaire Cut is for information only. Refer to Specifications for all Catalogue Numbers, Lamps, Finishes, Accessories, Etc.
TYPE:
PL
(1-3)
GL18 Gullwing LED Site and Area Luminaire, Large
Asymmetric Optical Orientation Information
Standard Optic Position
Optic Rotated Left (90°) Optic Position
Luminaires ordered with asymmetric optical systems in the standard
optic position will have the optical system oriented as shown below:
Luminaires ordered with asymmetric optical systems in the Optic
Rotated Left (90°) optic position will have the optical system oriented
as shown below:
Left side
of pole
Left side
of pole
Right side
of pole
Street Side
Right side
of pole
Street Side
Curbline
90°
270°
House Side
Curbline
90°
270°
House Side
0°
0°
Note: The hand hole will normally be located on the pole at the 0° point.
Note: The hand hole will normally be located on the pole at the 0° point.
Asymmetric Optical Orientation Information
Optic Rotated Right (270°) Optic Position:
Twin Luminaire Assemblies With Rotated Optical Systems
Luminaires ordered with asymmetric optical systems in the Optic
Rotated Right (270°) optic position will have the optical system
oriented as shown below:
Twin luminaire assemblies installed with rotated optical systems are an
excellent way to direct light toward the interior of the site (Street Side)
without additional equipment. It is important, however, that care be
exercised to insure that luminaires are installed in the proper location.
Left side
of pole
Right side
of pole
Left side
of pole
Right side
of pole
180°
Street Side
Street Side
Curbline
90°
270°
House Side
Curbline
House Side
0°
0°
Luminaires with Optic
Rotated Right (270°) are
installed on the LEFT
Side of Pole
Note: The hand hole will normally be located on the pole at the 0° point.
Luminaires with Optic
Rotated Left (90°) are
installed on the RIGHT
Side of Pole
Note: The hand hole location will depend on the drilling configuration
ordered for the pole.
GL18
05/15
page 7 of 8
District 2 North Parking Lot
Lighting Improvements
Aurora, CO
Not for construction,
demonstrates design intent
65%
Submit-
Date:
03-21-16
Note: This Luminaire Cut is for information only. Refer to Specifications for all Catalogue Numbers, Lamps, Finishes, Accessories, Etc.
TYPE:
PL
(1-3)
GL18 Gullwing LED Site and Area Luminaire, Large
Specifications
General Description
Thermal Management
Finish
The Philips Gardco Gullwing LED is defined
by its high performance, sleek profile and
rugged construction. Gullwing LED luminaires
combine LED performance excellence
and advanced Philips Gardco LED thermal
management technology with the distinct
Gullwing style to provide outdoor area lighting
that is both energy efficient and aesthetically
pleasing.
The Philips Gardco Gullwing LED provides a
one piece die cast aluminum door with integral
thermal radiation fins combined with lateral
air ways, to provide the excellent thermal
management so critical to long LED system
life. GL18 is UL listed from -40 to 40°C ambient.
Each standard color luminaire receives a
fade and abrasion resistant, electrostatically
applied, thermally cured, triglycidal
isocyanurate (TGIC) textured polyester
powdercoat finish. Standard colors include
bronze (BRP), black (BLP), white (WP), and
natural aluminum (NP). Consult factory for
specs on optional or custom colors.
Housing
A one-piece die cast aluminum housing
mounts directly to a pole or wall without
the need for a support arm. The low profile
rounded form reduces the effective projected
area of the luminaire to only
1.2 ft2 /.12 m2.
IP Rating
Gullwing LED 18" optics are IP66 rated.
LED Optical System
LED arrays are set to achieve IES Type II, Type
III, Type IV, Type V , available with internal
shields for back light control. Type 2, 3, 4 optics
can be factory set to 90 or 270° orientations.
Individual LED arrays are replaceable.
Luminaires feature high performance Class 1
LED systems.
Labels
Electrical
Limited Warranty
Luminaires are equipped with an LED driver
that accepts 120V through 277V, or 347V
through 480V, 50hz to 60hz, input. Driver
output is based on the LED wattage selected.
Component-to-component wiring within
the luminaire will carry no more than 80% of
rated current and is listed by UL. Power factor
is not less than 90%. Luminaire consumes
0.0 watts in the off state. All motion sensors
utilized consume 0.0 watts in the off state.
Surge protector standard. 10KA per ANSI/IEEE
C62.41.2.
5 year limited warranty. See philips.com/
luminaires for complete details and exclusions.
All luminaires bear UL or CUL (where
applicable) Wet Location labels. Gullwing LED
GL18 luminaires, with the exception of the
310W in 3000K are certified by DesignLights
Consortium.
LED Performance:
PREDICTED LUMEN DEPRECIATION DATA16
Ambient
Temperature
Driver mA
°C
25°C
up to 1050 mA
Calculated L70
Hours16,17
>100,000
L70 Per TM-2117,18
>60,000
Lumen Maintenance %
@ 60,000 hours
96%
16. Predicted performance derived from LED manufacturer’s data and engineering design estimates, based on
IESNA LM-80 methodology. Actual experience may vary due to field application conditions.
17. L70 is the predicted time when LED performance depreciates to 70% of initial lumen output.
18. Calculated per IESNA TM21-11. Published L70 hours limited to 6 times actual LED test hours.
© 2014 Koninklijke Philips N.V. All rights reserved.
Philips reserves the right to make changes in specifications
and/or to discontinue any product at any time without notice
or obligation and will not be liable for any consequences
resulting from the use of this publication.
philips.com/luminaires
GL18
05/15
Philips Lighting, North America Corporation
200 Franklin Square Drive, Somerset, NJ 08873
Tel. 855-486-2216
Imported by: Philips Lighting,
A division of Philips Electronics Ltd.
281 Hillmount Rd, Markham, ON, Canada L6C 2S3
Tel. 800-668-9008
page 8 of 8
District 2 North Parking Lot
Lighting Improvements
Aurora, CO
Not for construction,
demonstrates design intent
65%
Submit-
Date:
03-21-16
Note: This Luminaire Cut is for information only. Refer to Specifications for all Catalogue Numbers, Lamps, Finishes, Accessories, Etc.
TYPE:
PL
(1-3)
Job:
Type:
Notes:
100 Line LED
101 Performance Sconce LED
Philips Gardco 101 LED trapezoidal wedge high performance sconce luminaires are designed to integrate
naturally to wall surfaces. 101 LED luminaires are available with three (3) different distribution patterns,
providing full cutoff performance (in the normal downlight position) and featuring LED arrays. Luminaires
provide performance excellence and advanced Philips Gardco LED thermal management technology. High
performance Class 1 LED systems offer potential energy savings of 50 % or more compared to HID systems.
101 LED luminaires are also available with Automatic Profile Dimming, increasing savings by an additional 33%.
PREFIX
101L-DIM
DISTRIBUTION
LED WATTAGE
4
55LA
LED SELECTION
VOLTAGE
NW
UNIV
FINISH
OPTIONS
BLP
Enter the order code into the appropriate box above. Note: Philips Gardco reserves the right to refuse a configuration. Not all combinations and configurations are valid.
Refer to notes below for exclusions and limitations. For questions or concerns, please consult the factory.
PREFIX
101L
101L-DCC
101L-DIM
101L-APD
DISTRIBUTION
Trapezoidal Wedge
Trapezoidal Wedge
Trapezoidal Wedge
Trapezoidal Wedge
LED
LED
LED
LED
- Constant Wattage / Full Light Output
- Dual Arrays with Dual Circuit Control
- 0 - 10V Dimming (Control system by others.)
with Automatic Profile Dimming
2
3
4
Type II
Type III
Type IV
Wide Throw Optic, featuring Maximized Lateral Throw
Preferred Wide Throw Optic, featuring Improved Forward Throw
Maximized Forward Throw Optic
See page 3 for more detailed luminaire configuration information.
LED WATTAGE AND LUMEN VALUES
Ordering
Code
Average
System
Watts1
LED
Current
(mA)
LED
Selection
35LA
34
350
55LA
52
530
Luminaire Initial Absolute Lumens2,3
TYPE 2
TYPE 3
TYPE 4
NW
3,459
3,559
3,385
NW
4,785
5,021
4,709
Basis of Lumen Data
Photometric tests performed in compliance
with IESNA LM-79.
1. Wattage may vary by +/- 8% due to LED manufacturer forward volt specification and ambient temperature. Wattage shown is average for 120V through 277V input. Actual
wattage may vary by an additional +/- 10% due to actual input voltage.
2. Tests are in process for luminaires with the DL option , CW and WW luminaires. CW values may be approximated by applying a 1.08 multiplier to NW values shown.
Contact Gardco.applications@philips.com if any approximate estimates are required for design purposes.
3. LED arrays feature LEDs that provide from 100 to 130 lumens per watt when operated at 350 mA. Lumen values based on tests performed in compliance with IESNA LM-79.
LED SELECTION
CW
NW
WW
VOLTAGE
Cool White - 5700°K - 75 CRI
Neutral White - 4000°K - 70 CRI
Warm White - 3000°K - 80 CRI
UNIV
120
208
240
277
347
120V through 277V, 50hz or 60hz
© 2014 Koninklijke Philips N.V. All rights reserved.
G200-028 10/14 page 1 of 3 www.philips.com/luminaires
District 2 North Parking Lot
Lighting Improvements
Aurora, CO
Not for construction,
demonstrates design intent
65%
Submit-
Date:
03-21-16
Note: This Luminaire Cut is for information only. Refer to Specifications for all Catalogue Numbers, Lamps, Finishes, Accessories, Etc.
TYPE:
WL
(1-2)
100 Line LED
101 Performance Sconce LED
Page 2 of 3
FINISH
BRP
BLP
WP
NP
BGP
OC
OPTIONS
Bronze Paint
Black Paint
White Paint
Natural Aluminum Paint
Beige Paint
Optional Color Paint
Specify Optional Color or
RAL ex: OC-LGP or OC-RAL7024.
SC
Special Paint
F9
PCB9
DL6
PSO4,7
UT
WS5
WS/UT5
WG8
Fusing
Button Type Photocontrol
Diffusing Lens (reduces performance significantly)
Offset Polycarbonate Flat Shield
5° Uptilt
Wall Mounted Box for Surface Conduit
WS Option w/5° Uptilt
Wire Guard
4. Polycarbonate lenses carry a 1 year warranty only.
5. Rear entry permitted.
6. Not available with PSO option and not available with the WG option.
7. Not available with DL option and not available with the WG option.
8. Not available with DL option and not available with the PSO option.
9. Specify input voltage.
Specify. Must supply color chip.
DIMENSIONS
Mounting Plate
4 5/16"
10.95 cm
7"
17.78 cm
16 1/4"
41.28 cm
1 3/4" dia.
4.4 cm
9"
22.86 cm
3"
7.62 cm
Mounting Bolt Pattern
Note: Mounting plate center is located in the center of the luminaire width and 3.5"(8.89cm) above the luminaire bottom (lens down position). Splices must be
made in the J-box (by others). Mounting plate must be secured by max. 5/16" (.79cm) diameter bolts (by others) structurally to the wall.
LUMINAIRE CONFIGURATION INFORMATION
101L: Philips Gardco performance LED sconce providing constant wattage and constant light output when power to the luminaire is energized.
101L-DCC: Philips Gardco performance LED sconce provided with dual circuiting, and dual arrays, permitting separate switching of each led array.
101L-DIM: Philips Gardco performance LED sconce provided with 0 -10V dimming for connection to a control system provided by others.
101L-APD: Philips Gardco performance LED sconces with Automatic Profile Dimming are provided with a progammed LED Driver included. The LED driver is
factory programmed to go to 50% power, 50% light output two (2) hours prior to night time mid-point and remain at 50% for six (6) hours after night time midpoint. Mid-point is continuously calculated by the LED driver based on the average mid-point of the last two full night cycles. Short duration cycles, and power
interruptions are ignored and do not affect the determination of mid-point.
APD Dimming Profile:
2 Hours
6 Hours
100%
100%
50%
Power On
50%
Mid Point
Power Off
© 2014 Koninklijke Philips N.V. All rights reserved.
G200-028 10/14 page 2 of 3 www.philips.com/luminaires
District 2 North Parking Lot
Lighting Improvements
Aurora, CO
Not for construction,
demonstrates design intent
65%
Submit-
Date:
03-21-16
Note: This Luminaire Cut is for information only. Refer to Specifications for all Catalogue Numbers, Lamps, Finishes, Accessories, Etc.
TYPE:
WL
(1-2)
100 Line LED
101 Performance Sconce LED
Page 3 of 3
SPECIFICATIONS
GENERAL: Philips Gardco 101 LED Trapezoidal Wedge high performance
sconce luminaires are designed to integrate naturally to wall surfaces. 101 LED
luminaires are available with three (3) different distribution patterns, providing
full cutoff performance (in the downlight position) and featuring LED arrays.
Luminaires provide performance excellence and advanced Philips Gardco LED
thermal management technology. High performance Class 1 LED systems offer
potential energy savings of 50 % or more compared to HID systems. Surge
protector standard. 10KA per AN SI/IEEE C62.41.2.
THERMAL MANAGEMENT: Philips Gardco 101 LED luminaires utilize
extruded aluminum integral thermal radiation fins to provide the excellent
thermal management so critical to long LED system life.
HOUSING: Housings are die cast aluminum. A memory retentive gasket
seals the housing to the door frame to exclude moisture, dust, insects
and pollutants from the optical system. A black, die cast ribbed backplate
dissipates heat for longer system life.
DOOR FRAME: A single-piece die cast aluminum door frame integrates to
the housing form. The door frame is hinged closed and secured to the housing
with captive stainless steel fasteners. The heat and impact resistant 1/8"
(.32cm) tempered glass lens and one-piece gasket are mechanically secured to
the door frame with galvanized steel retainers.
IP RATING: Luminaires are rated IP66.
LED RELIABILITY:
PREDICTED LUMEN DEPRECIATION DATA
Ambient Temperature °C
25 °C
40 °C
LED Wattage / Driver mA
L70 Hours10
35LA / 350 mA
150,000
55LA / 530 mA
100,000
35LA / 350 mA
100,000
55LA / 530 mA
70,000
10. Predicted performance derived from LED manufacturer’s data and engineering design estimates,
based on IESNA LM-80 methodology. Actual experience may vary due to field application
conditions. L70 is the predicted time when LED performance depreciates to 70% of initial
lumen output.
FINISH: Each standard color luminaire receives a fade and abrasion resistant,
electrostatically applied, thermally cured, triglycidal isocyanurate (TGIC)
textured polyester powdercoat finish. Standard colors are as listed. Consult
factory for specs on custom colors.
LABELS: All luminaires bear UL or CUL (where applicable) labels. Lens down
application is Wet Location and lens up is Damp Location.
WARRANTY: Philips Gardco LED luminaires feature a 5 year limited
warranty, including a 5 year limited warranty covering the LED arrays. See
Warranty Information on www.sitelighting.com for complete details and
exclusions. Polycarbonate lenses carry a 1 year warranty only.
OPTICAL SYSTEMS: Philips Gardco 101 LED luminaires utilize lensed
LED arrays set to achieve IES Type II, Type III, and Type IV distributions.
Individual LED arrays are replaceable. Luminaires feature high performance
Class 1 LED systems.
FULL CUTOFF PERFORMANCE: Full cutoff performance means a luminaire distribution where zero candela intensity occurs at an angle at or above 90° above nadir .
Additionally, the candela per 1000 lamp lumens does not numerically exceed 100 (10 percent) at a vertical angle of 80° above nadir. This applies to all lateral angles around the
luminaire.
CUTOFF PERFORMANCE: Cutoff performance means a luminaire distribution where the candela per 1000 lamp lumens does not numerically exceed 25 (2.5 percent) at an
angle at or above 90° above nadir, and 100 (10 percent) at a vertical angle of 80° above nadir. This applies to all lateral angles around the luminaire.
© 2014 Koninklijke Philips N.V. All rights reserved.
Philips reserves the right to make changes in specifications
and/or to discontinue any product at any time without notice
or obligation and will not be liable for any consequences
resulting from the use of this publication.
Philips Lighting
North America Corporation
200 Franklin Square Drive
Somerset, NJ 08873
Tel. 855-486-2216
Imported by: Philips Lighting,
A division of Philips Electronics Ltd.
281 Hillmount Rd,
Markham, ON, Canada L6C 2S3
Tel. 800-668-9008
G200-028 10/14 page 3 of 3 www.philips.com/luminaires
District 2 North Parking Lot
Lighting Improvements
Aurora, CO
Not for construction,
demonstrates design intent
65%
Submit-
Date:
03-21-16
Note: This Luminaire Cut is for information only. Refer to Specifications for all Catalogue Numbers, Lamps, Finishes, Accessories, Etc.
TYPE:
WL
(1-2)
ASW-32G1
AeroScape LED Small Housing Wall and Surface Mount Series
Type: WL3
Job: District 2 North Parking Lot Lighting Improvements
Approvals:
Catalog Number:
ASW
-
32
- 700 -
NW
Driver
LED
Color
# of
LEDs
Series
-
4L
- UNV -
SM
-
Distribution
Voltage
Mounting
DD
-
Options
Finish
Date:
Page 1 of 10
Accessories
Overall Dimensions
ASW-32G1 Dimensions
Top View
15.6”
15.0”
39.6 cm
38.1 cm
End View
Side View
12.5”
31.7 cm
4.0”
10.1 cm
5.7”
14.6 cm
5.7”
3.1”
14.6 cm
7.9 cm
Weight: 13.4 lbs 6.1 kgs
Specifications
Rated System Life (LED life per L70)
Driver and LED life are rated up to 80,000 hrs
@ 40°C (104°F).
Predicted LED Life
See page for 5 for predicted L70 LED life.
Construction
Die-cast aluminum housing with corrosion resistant
hardware. Optic chamber and separate driver housing
constructed to IP66. Die-cast aluminum heatsink allows for
long life of LEDs up to 40°C ambient.
Thermal Management
IP66 rated thermal management system creates a vortex
of airflow with passthrough convective cooling system and
heat extraction.
LED and Board Array
Small housing: 32 Rebel ES LEDs.
Color temperature: Neutral White 4000 K +/- 250 K.
CRI ≥ 60.Metal core printed circuit board. RoHS compliant.
Driver
High efficiency multi-volt driver (50 or 60 Hz), maintains
constant current flow to LEDs to accommodate LED
variations. High power factor (>90% standard). Constant
current: 350, 530 or 700 mA. Voltage: 120-277, 347, 480.
Temperature range: -40°C (-40°F) to 40°C (104°F).
Exception: 700 mA unit: -40°C (-40°F) to 35°C (95°F).
Open/short circuit protection. RoHS compliant. Surge
protector standard. The surge protector is in accordance
with IEEE / ANSI C62.41.2 guidelines, with a surge current
rating of 10,000 amps.
LED Optical System
LED Pod optical assemblies. Type II, III, IV or Wall Throw
distribution. Fully gasketed Dust-Tite construction.
Employs Philips LEDGINE technology and Luxeon R LEDs.
Mounting
Surface mount standard. Contractor friendly integral
bubble mount for ease of installation. Can be mounted in
an inverted position for uplight illumination. Contractor
responsible for sealing housing to mounting surface.
Listings
ETL/cETL listed to the UL 1598 standard, suitable for Wet
Locations. Suitable for use in ambients from -40° to 40°C
(-40° to 104°F). See exception in driver specifications
for 700 mA units. The quality systems of this facility have
been registered by UL to the ISO 9001 series standards.
AeroScape wall mount series ‘ASW’ is a DesignLights
Consortium qualified product.
Warranty
Philips Gardco luminaires feature a 5 year limited warranty.
Philips Gardco LED luminaires with LED arrays feature a
5 year limited warranty covering the LED arrays and LED
drivers. Motion sensors are covered by warranty for 5
years by the motion sensor manufacturer.
Finish
Standard textured finish options available.
TSA = textured satin aluminium, TDB = textured dark
bronze, TBK = textured black, TWHT = textured white,
TGR = textured gray, TPG = textured Philips gray,
TGN = textured green, and RAL(*) = custom color
(* = specify RAL #).
© 2013 Koninklijke Philips N.V. (Royal Philips). All rights reserved.
Specifications are subject to change without notice.
www.philips.com/luminaires
G200-130/1114
District 2 North Parking Lot
Lighting Improvements
Aurora, CO
Not for construction,
demonstrates design intent
65%
Submit-
Date:
03-21-16
Note: This Luminaire Cut is for information only. Refer to Specifications for all Catalogue Numbers, Lamps, Finishes, Accessories, Etc.
TYPE:
WL 3
ASW-32G1
AeroScape LED Small Housing Wall and Surface Mount Series
Type: WL3
Job: District 2 North Parking Lot Lighting Improvements
Page 2 of 10
AeroScape Wall Mount Small Housing
ASW-32G1
Series
†
9 ASW
# of LEDs
†
9 32G1
Driver
LED Color
† 350
† 530
Distribution
†
9 NW
† 2L
Neutral
White
† 3L
✔ 700
†
Type II
Type III
✔ 4L
†
Type IV
† WT
Wall
Throw
Voltage
† 120
Mounting
Options7
✔ SM
†
† F12
Surface
Mount
† 208
(standard)
† 240
Single Fusing
(120, 277, 347V)
† DS506
† F22
Double Fusing
(208, 240, 480V)
† 277
† 347
† F32
† 480
✔ UNV1
†
† PCB2,3
Notes:
1) ‘UNV’ universal voltage, 120-277V.
Double Fusing
(208, 240, 480V)
Canadian Double Pull
5) 0-10V leads exiting luminaire supplied for connection to external secondary controls (by others).
6) Dynadimmer options and accessories are only available in 120-277V. Includes Dimming Driver (‘DD’) option.
† F1-KIT2
† TDB
Textured
Dark Bronze
† F2-KIT2
† TBK
Textured Black
† TWHT
Textured White
✔ TGR
†
Textured Gray
† DM506
† SG
Stone Guard
† DE256
† DL4
Diffuse Lens
† DE506
✔ DD5
†
Dimming Driver
† DCP6
Dynadimmer
Custom
Programming
7) ASW is compatible with a wide range of occupancy sensors, wireless controls and asset
management systems (by others). Contact factory.
Textured
Satin Aluminum
† DM256
Dynadimmer
Median Profile
† DE756
4) Luminaire efficiency will decrease from 0 to 10% depending on the spread of the optics.
† TSA
Dynadimmer
Safety Profile
† DM756
3) ‘PCB’ option not available in 480V.
Accessories (must be ordered separately)
† DS756
Photocontrol
Button
2) Specify voltage. Fusing and photocontrols not available with ‘UNV’ voltage option.
Finish
† DS256
Dynadimmer
Economy Profile
Distribution Patterns
Single Fusing
Field Installed Kit
(120, 277, 347V)
Double Fusing
Field Installed Kit
(208, 240, 480V)
† TGN
Textured Green
† TPG
Textured
Philips Gray
† RAL(*)
† F3-KIT2
Double Fusing
Field Installed Kit
(208, 240, 480V)
Canadian Double Pull
† DYN-KIT1
Type II (2L)
Type III (3L)
Type IV (4L)
Wall Throw (WT)
Dynadimmer USB
Cable Kit
(for field programming)
† DYN-KIT2
Dynadimmer Handheld
Programmer Kit
(for field programming)
Custom Color
(*specify RAL #)
© 2013 Koninklijke Philips N.V. (Royal Philips). All rights reserved.
Specifications are subject to change without notice.
www.philips.com/luminaires
G200-130/1114
District 2 North Parking Lot
Lighting Improvements
Aurora, CO
Not for construction,
demonstrates design intent
65%
Submit-
Date:
03-21-16
Note: This Luminaire Cut is for information only. Refer to Specifications for all Catalogue Numbers, Lamps, Finishes, Accessories, Etc.
TYPE:
WL 3
ASW-32G1
AeroScape LED Small Housing Wall and Surface Mount Series
Type: WL3
Job: District 2 North Parking Lot Lighting Improvements
Page 3 of 10
Option Details
F1
Single Fusing (120, 277, 347V)
F2
Double Fusing (208, 240, 480V)
F3
Double Fusing (208, 240, 480V)
PCB
Factory Installed Photocell Button
DD
Dimming Driver (0-10V)
Continuous dimming down to 10% power.
0-10V leads exiting luminaire supplied for
connection to external controls (by others).
(Canadian double pull)
Not available with 480 V.
Dynadimmer Details
DCP
The Dynadimmer programmer enables users to program the individual
Dynadimmer either on or off-site. For factory programming, submittals
required to set profile. For field programming,
DYN-KIT1 or DYN-KIT2 required.
Note: Voltage must be specified with fusing and photocell options.
SG
Stone Guard (included, field installed)
Dynadimmer Custom Programming
Dynadimmer - Safety Profile1
This mode focuses on safety by dimming during a limited period of time.
Decreases light levels to 25, 50, or 75% low during a four hour period. 2
DS25 25% Low
DL
DS50 50% Low
DS75 75% Low
Reduces glare from direct view of optics.
Dynadimmer - Median Profile1
This mode provides an ideal balance between illumination and energy savings.
Decreases light levels to 25, 50, or 75% low during a six hour period. 2
Luminaire efficiency will decrease from
0 to 10% depending on the spread of the optics.
DM25 25% Low
Diffuse Lens
DM50 50% Low
DM75 75% Low
Dynadimmer - Economy Profile1
This mode maximizes energy savings by dimming during a longer period of time.
Decreases light levels to 25, 50, or 75% low during an eight hour period. 2
DE25 25% Low
DE50 50% Low
DE75 75% Low
1) Dynadimmer not available in 347 or 480 V.
2) Can be modified later by the end-user with optional USB cable and free programming software.
Accessory Details
F1-KIT
Single Fusing Field Installed Kit (120, 277, 347V)
F2-KIT
Double Fusing Field Installed Kit (208, 240, 480V)
F3-KIT
Double Fusing Field Installed Kit (208, 240, 480V)
(Canadian double pull)
DYN-KIT1
Dynadimmer USB Cable Kit (for field programming)
The USB programmng cable is used to directly link and program
Dynadimmer 0-10V from a PC. When using this cable, no
programmer tool is needed. Dynadimmer software has a
special button to activate the USB feature. Software available
for free download at www.www.philips.com/lumimaires.com. Cable only.
DYN-KIT2
Dynadimmer Handheld Programmer Kit
(for field programming)
The Dynadimmer programmer enables users to program
the individual Dynadimmer either on or off-site.
Powered by 4 AA or LR6 batteries.
Handheld programmer with cables.
© 2013 Koninklijke Philips N.V. (Royal Philips). All rights reserved.
Specifications are subject to change without notice.
www.philips.com/luminaires
G200-130/1114
District 2 North Parking Lot
Lighting Improvements
Aurora, CO
Not for construction,
demonstrates design intent
65%
Submit-
Date:
03-21-16
Note: This Luminaire Cut is for information only. Refer to Specifications for all Catalogue Numbers, Lamps, Finishes, Accessories, Etc.
TYPE:
WL 3
ASW-32G1
AeroScape LED Small Housing Wall and Surface Mount Series
Type: WL3
Job: District 2 North Parking Lot Lighting Improvements
Page 4 of 10
Standard Wall Mount Details
Wall Mount Drill Template
3.375”
Bubble
Level
4.39”
11.15 cm
3.375”
5.7”
14.6 cm
Ø2.750”
Ø 3.50”
5.13”
15.6”
39.6 cm
13.03 cm
Photometric Data - ASW-32G1
Cat No.
ASW-32G1-350
ASW-32G1-530
ASW-32G1-700
(distribution)
System
Wattage
Fixture
Lumens
Type II (2L)*
39
3,494
Type III (3L)
35
3,768
Type IV (4L)
35
3,596
Wide Throw (WT) (Type II)
35
3,961
Optic
B
U
G
(backlight)
(uplight)
(glare)
90
1
0
108
1
0
103
1
113
Efficacy
CCT
IES File #
1
4000 K +/- 250 K
ASW-32G1-350-2L.IES
1
4000 K +/- 250 K
ASW-32G1-350-3L.IES
0
1
4000 K +/- 250 K
ASW-32G1-350-4L.IES
2
0
0
4000 K +/- 250 K
ASW-32G1-350-WT.IES
Type II (2L)
51
5,066
99
1
0
1
4000 K +/- 250 K
ASW-32G1-530-2L.IES
Type III (3L)
51
5,467
107
2
0
2
4000 K +/- 250 K
ASW-32G1-530-3L.IES
Type IV (4L)
51
5,219
102
1
0
1
4000 K +/- 250 K
ASW-32G1-530-4L.IES
Wide Throw (WT) (Type II)
51
5,747
113
2
0
1
4000 K +/- 250 K
ASW-32G1-530-WT.IES
Type II (2L)*
79
6,195
78
1
0
1
4000 K +/- 250 K
ASW-32G1-700-2L.IES
Type III (3L)
71
6,683
94
2
0
2
4000 K +/- 250 K
ASW-32G1-700-3L.IES
Type IV (4L)
71
6,379
90
2
0
2
4000 K +/- 250 K
ASW-32G1-700-4L.IES
Wide Throw (WT) (Type II)
71
7,025
99
3
0
1
4000 K +/- 250 K
ASW-32G1-700-WT.IES
* LM-79 test report data was generated by a 3rd party independent lab - Luminaire Testing Laboratory (LTL).
Backlight
- refers to light directed opposite the target area, which may create light tresspass. Backlight is commonly behind the luminaire.
Uplight
- is illumination directed above the horizontal plane of the luminaire (90°) which causes artificial sky glow.
Glare
- is the amount of light from the luminaire emitted in directions or at angles that cause glare, which can be annoying or visually disabling.
© 2013 Koninklijke Philips N.V. (Royal Philips). All rights reserved.
Specifications are subject to change without notice.
www.philips.com/luminaires
G200-130/1114
District 2 North Parking Lot
Lighting Improvements
Aurora, CO
Not for construction,
demonstrates design intent
65%
Submit-
Date:
03-21-16
Note: This Luminaire Cut is for information only. Refer to Specifications for all Catalogue Numbers, Lamps, Finishes, Accessories, Etc.
TYPE:
WL 3
ASW-32G1
AeroScape LED Small Housing Wall and Surface Mount Series
Type: WL3
Job: District 2 North Parking Lot Lighting Improvements
Page 5 of 10
LED Lumen Maintenance Data - ASW-32G1
ASW-32G1 @ 350 mA
ASW-32G1 @ 530 mA
ASW-32G1 @ 700 mA
5
10
15
20
25
30
35
40
5
10
15
20
25
30
35
40
5
10
15
20
25
30
35
40
Junction Temperature2
30.8
35.8
40.8
45.8
50.8
55.8
60.8
65.8
42.8
47.8
52.8
57.8
62.8
67.8
72.8
77.8
57.2
62.2
67.2
72.2
77.2
82.2
87.2
-
Thermal Factor3
1.04
1.03
1.02
1.01
1.00
0.99
0.98
0.97
1.04
1.03
1.02
1.01
1.00
0.99
0.98
0.97
1.04
1.03
1.02
1.01
1.00
0.99
0.98
-
0
1.04
1.03
1.02
1.01
1.00
0.99
0.98
0.97
1.04
1.03
1.02
1.01
1.00
0.99
0.98
0.97
1.04
1.03
1.02
1.01
1.00
0.99
0.98
-
8,000 / 2.2
1.04
1.03
1.02
1.01
1.00
0.99
0.97
0.96
1.04
1.02
1.01
1.00
0.99
0.98
0.97
0.96
1.03
1.02
1.01
1.00
0.99
0.98
0.97
-
16,000 / 4.4
1.03
1.02
1.01
1.00
0.99
0.98
0.97
0.95
1.03
1.02
1.01
0.99
0.98
0.97
0.96
0.95
1.02
1.01
1.00
0.99
0.98
0.96
0.95
-
24,000 / 6.6
1.02
1.01
1.00
0.99
0.98
0.97
0.96
0.94
1.02
1.01
1.00
0.98
0.97
0.96
0.95
0.93
1.01
1.00
0.99
0.97
0.96
0.95
0.93
-
32,000 / 8.8
1.02
1.00
0.99
0.98
0.97
0.96
0.95
0.93
1.01
1.00
0.99
0.97
0.96
0.95
0.94
0.92
1.00
0.99
0.97
0.96
0.95
0.93
0.91
-
40,000 / 11.0
1.01
1.00
0.99
0.97
0.96
0.95
0.94
0.92
1.00
0.99
0.98
0.96
0.95
0.94
0.92
0.91
0.99
0.98
0.96
0.95
0.93
0.91
0.90
-
48,000 / 13.2
1.00
0.99
0.98
0.97
0.95
0.94
0.93
0.91
0.99
0.98
0.97
0.95
0.94
0.93
0.91
0.90
0.98
0.96
0.95
0.93
0.92
0.90
0.88
-
56,000 / 15.3
1.00
0.98
0.97
0.96
0.95
0.93
0.92
0.90
0.98
0.97
0.96
0.94
0.93
0.92
0.90
0.88
0.97
0.95
0.94
0.92
0.90
0.88
0.85
-
64,000 / 17.5
0.99
0.98
0.96
0.95
0.94
0.92
0.91
0.89
0.98
0.96
0.95
0.93
0.92
0.90
0.89
0.87
0.96
0.94
0.92
0.90
0.88
0.86
0.83
-
72,000 / 19.7
0.98
0.97
0.96
0.94
0.93
0.92
0.90
0.88
0.97
0.95
0.94
0.92
0.91
0.89
0.87
0.85
0.94
0.93
0.91
0.88
0.86
0.83
0.81
-
80,000 / 21.9
0.97
0.96
0.95
0.93
0.92
0.91
0.89
0.87
0.96
0.94
0.94
0.91
0.90
0.87
0.85
0.83
0.93
0.91
0.88
0.86
0.83
0.81
0.78
-
88,000 / 24.1
0.97
0.95
0.94
0.93
0.91
0.90
0.88
0.86
0.95
0.94
0.92
0.90
0.88
0.85
0.83
0.81
0.91
0.89
0.86
0.84
0.81
0.79
0.76
-
96,000 / 26.3
0.96
0.95
0.93
0.92
0.90
0.89
0.86
0.84
0.94
0.93
0.90
0.88
0.86
0.83
0.81
0.79
0.89
0.86
0.84
0.81
0.79
0.76
0.74
-
104,000 / 28.5
0.95
0.94
0.93
0.91
0.89
0.87
0.85
0.82
0.93
0.91
0.89
0.86
0.84
0.81
0.79
0.76
0.87
0.84
0.82
0.79
0.76
0.73
0.71
-
112,000 / 30.7
0.95
0.93
0.92
0.90
0.87
0.85
0.83
0.81
0.91
0.89
0.87
0.84
0.82
0.79
0.76
0.74
0.84
0.82
0.78
0.75
0.73
0.71
0.69
-
120,000 / 32.9
0.94
0.92
0.90
0.88
0.86
0.83
0.81
0.79
0.89
0.87
0.85
0.82
0.80
0.76
0.74
0.71
0.81
0.78
0.75
0.72
0.70
0.68
-
-
128,000 / 35.1
0.93
0.91
0.89
0.86
0.84
0.82
0.79
0.77
0.87
0.85
0.83
0.80
0.76
0.73
0.71
0.69
0.77
0.74
0.71
0.69
-
-
-
-
136,000 / 37.3
0.91
0.89
0.87
0.85
0.82
0.80
0.77
0.74
0.86
0.83
0.80
0.76
0.73
0.70
0.68
-
0.73
0.70
0.68
-
-
-
-
-
144,000 / 39.5
0.90
0.87
0.85
0.83
0.81
0.77
0.74
0.71
0.84
0.80
0.76
0.72
0.70
-
-
-
0.68
-
-
-
-
-
-
-
152,000 / 41.6
0.88
0.86
0.84
0.82
0.77
0.74
0.70
0.68
0.79
0.74
0.71
0.68
-
-
-
-
-
-
-
-
-
-
-
-
160,000 / 43.8
0.86
0.84
0.82
0.77
0.73
0.70
-
-
0.73
0.69
0.67
-
-
-
-
-
-
-
-
-
-
-
-
-
168,000 / 46.0
0.85
0.82
0.77
0.72
0.69
-
-
-
0.67
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
176,000 / 48.2
0.83
0.75
0.71
0.67
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
184,000 / 50.4
0.73
0.68
0.65
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
192,000 / 52.6
0.63
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Predicted Life
Hours of operation / Years based on 10 hrs/day burn cycle
Outdoor Ambient Temp (°C)1
Notes:
1. Outdoor ambient temperature is based on annual average operating air temperature as seen by the fixture within its environmental conditions.
2. Junction temperature is calculated from in-situ, solder point measurement per LED manufacturers recommendation, and will vary based on drive current and nominal forward voltage of the LED.
3. Thermal factor is a prorate or derate value based on the in-situ solder point measurement and the relative luminous flux provided by the LED manufacturer.
4. LED Lumen Maintenance Data chart is actual lumen adjustment per the operating ambient. No additional prorate or derate required.
Notes:
Pb
lead-free
9
R
oHS
2002/95/EC
© 2014 Koninklijke Philips N.V. All rights reserved.
Philips reserves the right to make changes in specifications
and/or to discontinue any product at any time without notice
or obligation and will not be liable for any consequences
resulting from the use of this publication.
Philips Lighting
North America Corporation
200 Franklin Square Drive
Somerset, NJ 08873
Tel. 855-486-2216
Imported by: Philips Lighting,
A division of Philips Electronics Ltd.
281 Hillmount Rd,
Markham, ON, Canada L6C 2S3
Tel. 800-668-9008
G200-130 11/14 page 5 of 5 www.philips.com/luminaires
District 2 North Parking Lot
Lighting Improvements
Aurora, CO
Not for construction,
demonstrates design intent
65%
Submit-
Date:
03-21-16
Note: This Luminaire Cut is for information only. Refer to Specifications for all Catalogue Numbers, Lamps, Finishes, Accessories, Etc.
TYPE:
WL 3
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising