Unpacking information
Remove the Packing List and verify that you have received all equipment,
including the following (quantities in parentheses):
FL-30000 Series Flowmeter (1)
Rubber Gasket (1)
Stainless Steel Clamps (2)
Operator's Manual (1)
If you have any questions about the shipment, please call the OMEGA
Customer Service Department.
When you receive the shipment, inspect the container and equipment for signs
of damage. Note any evidence of rough handling in transit. Immediately report
any damage to the shipping agent.
NOTE |
The carrier will not honor damage claims unless all shipping
material is saved for. inspection. After examining and removing
contents, save packing material and carton in the event reshipment
IS necessary.
Description
FL-30000 Series Flowmeters use a pitot tube pickup and a hardedged float
design to provide a convenient and economical means of measuring water flow
in a closed-pipe system. A one-piece, impact-resistant machined acrylic body
offers the strength and long service required in most commercial and industrial
applications. The low flow rate models are ideal for applications where flow
rates are typically low, and such as in solar-heated pools and spas, electronics
and irrigation.
Available Models
Part Number GPM LPM Pipe Size
FL-30001 5-40 20-150 1"
FL-30002 20-100 75-375 11/2"
FL-30003 8-30 30-110 11/5"
FL-30004 40-150 150-550 2"
FL-30005 15-70 60-260 2"
FL-30006 60-240 250-900 21/5"
FL-30007 80-300 300-1125 3"
FL-30008 40-140 160-520 3"
FL-30009 125-500 500-2000 4"
FL-30010 250-1050 900-3900 6"
FL-30011 500-1900 | 1800-7200 8"
To use flowmeter for copper tube applications, add suffix "-T" to the part number.
All models have scales on both sides.
Locating the Flowmeter INSTALLATION DRAWING
Install the flowmeters with at least the minimum di- — PIPE A 0. X10 ————
mensions called for in the installation drawing. T=
READ FLOAT
For all units except the FL-30010 and the FL-30011 | [| ATTOP
ffowmeters, drill a 5/8" to 11/16" diameter hole atthe | (9075 || _sraness steer
top of the pipe. For the FL-30010 and the FL-30011 —=| / CLAMP
flowmeters, drill a 3/4" or 11/16" hole. Carefully re- GASIET- |——=
move all burrs. Use a drill guide fixture. N ой PITOT TUBE
So
Typical Installation
Insert the pitot tube, with a gasket in place, into the || |
drilled pipe. Tighten the clamps altemately, a little at
a time. Make certain the flow direction is towards the
pitot tube opening.
Maintenance
Little flowmeter maintenance is required. Should the meter fail to read, make certain:
* that the pitot tube opening is unobstructed, -
* that the pitot tube opening faces in the directions of the flow,
* that you have installed the meter on the correct type and size of pipe.
Use mild soap on the outside of the flowmeter.
4
WARNING
If the pressure is tured on when the cap is off, you will lose the float. Be careful of
your eyes. Floats are not sold as spare parts.
Specifications т FL-30000 Series Flowmeter
270
Accuracy: +10% of full scale E
Meter Body Construction: Acrylic 230
Temperature Limit: 88°C (190°F) P
Pressure Limit: 150 PSI E
Pressure Drop: 0 PSI R 190
Capacity: ‚ 210 1900 GPM A
Mounting: Horizontal Pipe Ts
Piping Connection: 1" to 8" pipe or copper U
tube, depending on R
the mode! ordered E 110
Shipping Weight: 0.45 kg (1 Ib)
=
70
120 150
30 60
STATIC PRESSURE PSI
Maximum Temperature 190 F
Maximum Pressure 150 PSI
¡CE OMEGA
Аа ФИННЫ Teaimeleghes Company
Servicing USA and Canada: Call OMEGA Toll free
USA Canada
One Omega Drive, Box 4047 976 Bergar
Stamford, CT 06907-0047 Laval (Quebec) H7L 5A1
Telephone: (203) 359-1660 Telephone: (514) 856-6928
FAX: (203) 359-7700 FAX: (514) 856-6886
Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA™
Customer Service: 1-800-622-2378 / 1-800-622-BEST™
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN™
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Servicing Europe: United Kingdom Sales and Distribution Center
25 Swannington Road, Broughton Astley, Leicestershire
LE9 6TU, England
a Telephone: 44 (1455) 285520 FAX: 44 (1455) 283912
я "Е =
OMEGA warrants this unit to be free of defects in materials and workmanship and to give satisfactory ser-
vice for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month
grace period to the norma! one (1) year product warranty to cover handling and shipping time. This
ensures that OMEGA's customers receive maximum coverage on each product. If the unit should malfunc-
tion, it must be returned to the factory for evaluation. OMEGA's Customer Service Department will issue an
Authorized Return (AR) number immediately upon phone or writfen request. Upon examination by OMEGA,
if the unit is found to be defective it will be repaired or replaced at no charge. However, this WARRANTY is
VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a
result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication;
misuse or other operating conditions outside of OMEGA's control. Components which wear or which are
damaged by misuse are not warranted. These include contact points, fuses, and triacs.
OMEGA is glad to offer suggestions on the use of its various products. Nevertheless, OMEGA
only warrants that the parts manufactured by it will be as specified and free of defects.
OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER,
EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING
ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
HEREBY DISCLAIMED.
LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total
liability of OMEGA with respect to this order, whether based on contract, warranty, negligence,
indemnification, strict liability or otherwise, shall not exceed the purchase price of the
component upon which liability is based. In no event shail OMEGA be liable for consequential,
incidental or special damages.
Every precaution for accuracy has been taken in the preparation of this manual; however, OMEGA
ENGINEERING, INC. neither assumes responsibility for any omissions or errors that may appear nor
assumes liability for any damages that resuit from the use of the products in accordance with the
information contained in the manual.
SPECIAL CONDITION: Should this equipment be used in or with any nuclear installation or activity, purchas-
er will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of
the use of the equipment in such a manner.
NE RETURN REQUESTS / INQUIRIES semence
Direct all warranty and repair requests/inquiries to the OMEGA ENGINEERING Customer Service Department.
BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED
RETURN (AR) NUMBER FROM OMEGA'S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PRO-
CESSING DELAYS). The assigned AR number should then be marked on the outside of the return package
and on any correspondence.
FOR WARRANTY RETURNS, please have the FOR NON-WARRANTY REPAIRS OR
following information available BEFORE contacting consult OMEGA for current repair/calibration
EGA: charges. Have the following information available
1.PO. number under which the product was BEFORE contacting OMEGA:
PURCHASED, 1.PO. number to cover the COST of the repair/
2.Model! and serial number of the product under calibration,
warranty, and 2.Model and serial number of product, and
3.Repair instructions and/or specific problems 3. Repair instructions and/or specific problems
relative to the product. relative to the product.
OMEGA: policy is to make running changes, not model changes, whenever an improvement is possible.
This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 1995 OMEGA ENGINEERING, INC. All rights reserved. This documentation may not be copied,
photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in
whole or in part, without prior written consent of OMEGA ENGINEERING, INC.
M2063 /0595 CJSOS95MAJ2B
">