M3 – 5-digit digital panel meter in 96x24 mm (BxH) AC voltage signals / AC current signals – rms-value (TRMS) 300 VAC, 5 AAC • red display from -19999…99999 digits (optional green, orange, blue or tricolour display) • installation depth: 120 mm without plug-in screw terminal • multi voltage power supply unit 100-240 VAC • adjustment via factory setting or directly on the sensor signal • min/max-memory with adjustable permanent display • 30 additional adjustable support points • display flashing at threshold value exceedance / undercut • navigation keys for the triggering of Hold, Tara, display change, setpoint setting, alarm actuation • flexible alarm system with adjustable delay times • flexible power measurement and energy measurement at constant voltage • mathematical functions like reciprocal value, square root, square and rounding • constant setting / setpoint setting • sliding averaging • brightness control via parameter or front keys • programming interlock via access code • protection class IP65 at the front • plug-in screw terminal • optional: 1 or 2 relay outputs • optional: 1 independently scalable analog output • accessories: pc-based configuration-kit PM-TOOL with CD & USB adapter • on demand: devices for working temperatures of -20°C…60°C or -40°C…70°C Update 08/09/2016- m3_ac voltage_h_96x24.gb.doc Errors and omissions excepted. Page 1 96x24 ORDER NUMBER EUR (without options) • AC current, ac voltage (true RMS value) – special measuring inputs H Supply 100-240 VAC, DC ± 10% M3-3VR5B.0H04.S70BD 345,00 • Product key options M 3- 3 V R 5 B. 0 H 0 4. S 7 0 B D EUR 1 1 relay output (with option analog output only 1 switching point is possible) 20,00 2 2 relay outputs 30,00 1 without keypad, operation via PM-TOOL 10,00 X Analog output 0/4-20 mA, 0-10 VDC 90,00 B Blue 44,00 G Green 10,00 Y Orange T Tricolour (Red-Green-Orange) 4,00 30,00 On demand state dimension unit on order, e.g. V. • Parameterisation software PC based configuration software PM-Tool for devices without keypad, for a simple adjustment of standard devices, incl. CD & USB-adapter. Programming happens via an interface on the back. Update 08/09/2016- m3_ac voltage_h_96x24.gb.doc Errors and omissions excepted. PM-TOOL-MUSB4 Page 2 89,00 • Technical data Dimensions Housing Panel cut-out Fixing Housing material Sealing material Protection class Weight Connection B96 x H24 x D120 mm, (incl. plug-in terminal D= 145 mm cable outlet at the back) 92.0+0.8 x 22.2+0.3 mm screw elements for a wall thickness up to 10 mm PC Polycarbonate, black EPDM, 65 Shore, black at the front IP65 standard, at the back IP00 approx. 250 g plug-in terminal; wire cross section up to 2.5 mm2 Display Display Digit height Segment colour Range of display Threshold value Overflow Underflow Display time 5-digit 14 mm red (Standard), optional in green, orange, blue or tricolour (red/green/orange) -19999 to 99999 optical display flashing horizontal bars at the top horizontal bars at the bottom 0.1 to 10.0 seconds Measuring input Measuring range Input resistance Measuring fault 300 VAC / 5 AAC Ri at ~ 1 MΩ / Ri at ~ 0.02 MΩ 0.5 % of final value with 50 Hz…1 kHz to crest factor 4, ± 1 digit for input signals from 1%...100% of final value 100 ppm/K 0.1 … 10.0 seconds U/F-conversion approx. 18 bit at 1s measuring time Temperature drift Measuring time Measuring principle Resolution Analog output with change-over contact 250 V / 2 AAC, 30 V / 2 ADC 30 * 103 at 2 AAC, 2 ADC ohm resistive burden, 10 * 106 mechanically Separation according to DIN EN50178 / Specific values according to DIN EN 60255 0-10 VDC / burden ≥ 10 kΩ, 0/4-20 mA / burden ≤ 500 Ω, 16 bit Power pack Supply 100-240 VAC 50/60 Hz, DC ±10 % (max. 10 VA) Memory EEPROM Data preservation ≥ 100 years at 25°C Ambient condition Working temperature Storing temperature Climatic density 0 to +50°C -20 to +80°C relative humidity 0-85% on years average without dew CE-sign Conformity to directive 2014/30/EU EMV EN 61326, EN 55011 Safety standard According to low voltage directive 2014/35/EU, EN 61010; EN 60664-1 Output Relay Switching cycle Housing: 24,0 3,0 Se alin g l ina rm e t ) -in s) 4,0 (15 . plug ption 0 , l o 5 c 14 th in s on d p n e n d epe atio pth d l l a t e Ins (D 96 ,0 Gap for physical unit Update 08/09/2016- m3_ac voltage_h_96x24.gb.doc Errors and omissions excepted. Page 3 • Order key M 3- 3 V R 5 B. 0 H 0 4. S 7 0 B D Standard type M-Line Dimension D physical unit (on demand) Installation depth 145 mm incl. plug-in terminal (154 mm) 3 Version B B Housing size 96x24x120 mm (BxHxT) 3 Switching points 0 without 1 1 relay output Display type V, A V 2 2 relay outputs Blue B 1 without keypad, operation via PM-TOOL Green G 7 IP65 / plug-in terminal Red R Red/Green/Orange T Orange Y Display colours Protection class Supply voltage S 100-240 VAC Number of digits 5-digits Measuring input 5 4 AC, TRUE RMS Digit height 14 mm Analog output B 0 without X 1x 0-10 VDC, 0/4-20 mA Digital input without 0 Special measuring input H 300 VAC, 5 AAC Update 08/09/2016- m3_ac voltage_h_96x24.gb.doc Errors and omissions excepted. Page 4
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement