WESTBOURNE CLOSE COUPLED PAN
FITTING INSTRUCTIONS
Please retain for future reference
INSTALLATION OF FLUSH VALVE
Flush valve body
INSTALLATION OF FILL VALVE
Install the fill valve to the tank body using the rubber seal and plastic nut. Ensure the float cup has room to move up and down freely. The fill valve is pre-set to a height suitable for the cistern tank Turn the flush valve body anti-clockwise to part it from the flush valve seat Flush valve seat
Install flush valve seat and seal as shown
Seal
Cistern tank
Fixing nut
Rubber seal
Washer
Plastic nut
FILL VALVE ADJUSTMENT
The fill valve is factory set but if adjustment is required follow the instructions below.
Open the stopper to allow the float to slide up and down. Close stopper once float is in position.
Stopper
WB700CP / WB64CCC
FLUSH VALVE ADJUSTMENT
The flush valve is factory set but if adjustment is required see diagram below.
Reduced flush adjustment
Full flush adjustment
Flush valve body
Insert flush valve body into flush valve seat, turn it clockwise until you hear a “click”
Flush valve seat
Customer Services, R2, Brassmill Lane Trading Estate, Bath, BA1 3JF
TEL: 01225 303 900 | FAX: 01225 448 877 | [email protected] | www.r2bathrooms.co.uk
FINE ADJUSTMENT
Turn screw for fine adjustment of float height. Anticlockwise to lower float.
Clockwise to heighten float.
IMPORTANT
Flush out all impurities in the cistern prior to installation.
Cistern fittingd are suitable for Water pressure: 0.2 - 8 bar
REF: MB.R2.WEST | V1.00
WESTBOURNE CLOSE COUPLED PAN
FITTING INSTRUCTIONS
Please retain for future reference
FITTING THE CISTERN TO THE TOILET PAN
With the flush valve and inlet valve fitted and adjusted the cistern tank can be fitted to the pan.
Fit the gasket around the flush valve outlet on the underside of the cistern.
When fitting the cistern to the pan take care to ensure the gasket is properly aligned in the gasket location. Failing to do so could result in leakage.
INSTALLING PUSH BUTTON
Fit the push button to the cistern lid using the plastic bracket.
Ensure the pins make contact with the flush buttons on the flush valve. To adjust the length of the rods turn the nut clockwise and anti-clockwise.
WB700CP / WB64CCC
Water supply connection
Soil pipe
Gasket
Insert the cistern fitting bolts arranging the components as shown in the diagram below.
Firmly tighten the nuts and wing nuts taking care not to overtighten as this could damage the ceramic.
Fixing bolt
Cistern base
Metal washer
Nut
Toilet pan
Nut
Conical washer
Gasket
Metal washer
MAKING PLUMBING CONNECTIONS
Connect the soil pipe and ensure it is adequately sealed around the toilet pan outlet to prevent leakage.
The inlet valve has a threaded connector. It is recommended that this thread is wrapped in PTFE tape before connecting the water supply.
Do not overtighten the supply to the inlet valve as this could damage the inlet valve causing leakage.
After connecting the water supply to the inlet valve check that the inlet valve components do not touch the internal walls of the cistern and the float can move freely up and down.
Check all connections are secure and a soil pipe is fitted before testing the flush.
Customer Services, R2, Brassmill Lane Trading Estate, Bath, BA1 3JF
TEL: 01225 303 900 | FAX: 01225 448 877 | [email protected] | www.r2bathrooms.co.uk
OPERATION
Press the large button once for a large flush (6 litres factory setting)
Press the small button once for a small flush (4 litres factory setting)
CARE
DO NOT introduce caustic chemical substances (e.g. containing chlorine compounds or similar). These can damage the valve components and cause failure.
REF: MB.R2.WEST | V1.00