Scupper RetroDrain


Add to my manuals
2 Pages

advertisement

Scupper RetroDrain | Manualzz

Scupper RetroDrain

P R O D U C T D A T A S P E C I F I C A T I O N S

PRODUCT DESCRIPTION

Designed for existing through-wall/ side-wall or scupper drainage pipes, the aluminum and stainless steel drain components provide durability and compatibility with single ply, BUR and modified bitumen roofing systems. A metal clamping assembly creates a compression type termination in both vertical and horizontal wall flashings. The Scupper RetroDrain features the patented RAC Backflow

Compression Seal for attachment to PVC or cast iron leader pipes, and a removable drain strainer. Available in 3-in., 4-in., 5-in. and 6-in. sizes. Custom configurations are also available.

FEATURES & BENEFITS

• Pre-punched drain flange provides stable attachment to the wall and roof deck.

• The RAC Backflow Compression Seal is quickly activated at drain flange level to protect the roofing system and building contents from water backup damage.

• .125-in. metal clamping ring assembly provides a compression type termination for the vertical and horizontal roof flashings. Stainless steel studs and lock nuts secure the clamping ring assembly to the drain flange.

• .060-in thick drain strainer is easily secured to the drain body with four stainless steel wing nuts and provides protection against rooftop debris.

• Simple and easy to install, saving the contractor time and money.

APPROvAlS

& STANDARDS

ANSI/SPRI RD-1 – developed by SPRI

(Sheet membrane and component suppliers to the commercial roofing industry) a certified canvasser of ANSI (American National

Standards Institute), and features a test protocol designed to assure a leak-free connection to existing plumbing.

IAPMO PS 97-96 – a standard plumbing industry test designed to check for leakage at connections under a 10 foot head of water for a 24 hour period. This test was performed by the Smith-Emery Company, a nationally recognized independent test laboratory providing physical testing of construction related materials. The Scupper

RetroDrain produced no leakage.

PHYSICAl DATA

The data below is constant for all OMG Scupper

RetroDrains.

DRAIN BODY SEAL

.080" thick aluminum Watertight RAC Backflow

Compression Seal requires

7 /

16

" wrench

FLANGE

16" x 10" x 10"

STRAINER DOME

.060" thick aluminum

STEM

9" length

CLAMP RING

.125" thick metal

ORDERING INFORMATION

CAT. NO.

SIzE PKG WEIGHT

SCUPRD3 3" Each 20 lbs.

SCUPRD4

SCUPRD5

SCUPRD6

4"

5"

6"

Each

Each

Each

20 lbs.

20 lbs.

20 lbs.

153 Bowles RoAd, AgAwAm, mA 01001

800.633.3800 www.olyfAst.com [email protected]

RetroDrain ® and OlyFlow ® are trademarks of OMG, Inc. Copyright © 2010 OMG, Inc. All rights reserved.

MADE IN USA

Scupper RetroDrain

I N S T A l l A T I O N P R O C E D U R E

FOR USE WITH

All types of roof covers.

JOB PREPARATION

The existing leader pipe shall be cleaned of excess bitumen build-up, dirt and debris.

Remove the clamping ring assembly and bolts from the existing drain and discard. If required, comply with roof manufacturer’s directions for additional cleaning or detailing.

STEP 1

Important – The aluminum activation cone may have settled into the backflow seal during shipping, which may partially activate the seal.

To deactivate the seal, simply push down on the top of the two backflow bolts. Note: The top of the tapered metal cone should remain inside the bottom of the urethane seal. Do not fully disengage the cone from the urethane seal.

STEP 2

Place the Scupper Retrofit Drain Assembly into the existing drain leader (vertical or horizontal) pipe. The drain flange(s) should be in contact with the surface of both the wall and roof.

STEP 3

Using the pre-punched holes in the perimeter of the flange, secure the drain flange to the substrate with appropriate fasteners.

STEP 4

Hand tighten the 7 /

16

-in. bolts on the backflow rods to activate the seal. Alternate tightening between the bolts for an even seal expansion.

Do not overtighten.

STEP 5

Install roof flashing material into place per primary roofing manufacturer’s drain flashing details.

STEP 6

Install the metal clamping assembly into position by hand-tightening the lock nuts provided. Do not overtighten.

STEP 7

Install the drain strainer over the center of the drain opening and secure to 4 studs with the wing nuts provided.

For technical assistance contact

OMG at 800.633.3800.

Pre-Punched Holes

Drain Strainer

Studs for Clamping

Device & Strainer

Securement

Flange

Existing Drain Bowl

Aluminum Tubing

Compressible Urethane

Backflow Seal

Cast Aluminum Activation Cone

VERTICAL INSTALLATION

Clamping Device

Drain Flange

HORIZONTAL INSTALLATION

7 /

16

" Stainless Steel Bolt Heads for

Activation of the Backflow Seal

Stainless Steel Rods for Backflow Seal Activation

Flange

Aluminum Tubing

153 Bowles RoAd, AgAwAm, mA 01001

800.633.3800 www.olyfAst.com [email protected]

SuperDome ® and OlyFlow ® are trademarks of OMG, Inc. Copyright © 2010 OMG, Inc. All rights reserved.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement