08 27114 00- CPLP
2/2/05
9:49 am
Page 1
Chimney Hood
CPLP models
User & Installation Instructions
08 27114 00- CPLP
2/2/05
9:49 am
Page 2
Stoves Customer Care
Thank you for choosing this appliance from Stoves.
Should you need to contact us however, please call the number below and our
Customer Care Centre staff will be pleased to help in any way they can.
0870 444 9929
When you dial this number you will hear a recorded message and be given a
number of options. This indicates that your call has been accepted and is being
held in a queue. Calls are answered in strict rotation as our Customer Care
Representatives become available.
Opening Hours for Customer Care Centre
Monday to Friday
8am - 8pm
Saturday
8.30am - 6pm
Sunday
10am - 4pm
When calling please have to hand you appliances model an serial numbers.
These numbers help us to quickly identify your product and enable our Customer
Care team to provide you with the most up to date advice and support.
Outside the UK and Northern Ireland, refer to your local supplier.
08 27114 00- CPLP
2/2/05
9:49 am
Page 3
Contents
User’s Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 5
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Parts Identification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Using the Hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 10
Regulations and standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Ventilation & Mounting height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Method 1: Re-circulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Method 2: Extraction through an outside wall . . . . . . . . . . . . . . . . . . . . . . . . . 8
Wall Fixing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Installation Illustrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Electrical Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Customer Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1
08 27114 00- CPLP
2/2/05
9:49 am
Page 4
Introduction
Thank you for buying this Stoves hood,
we hope that it makes an attractive and
useful addition to your kitchen.
use as an exhausting (air evacuation
to the outside) or filtering (indoor air
re-cycling) hood.
Note: If you wish to install the hood
for extraction through an outside wall,
a compatible ducting kit should be
obtained.
This handbook contains information
which will help you to install and use your
new hood, and we recommend that you
read it fully before you start.
This handbook is for the following hoods:
Stoves 600CPLP
Stoves 900CPLP
Stoves 1000CPLP
Stoves 1100CPLP
Because of the complexity and weight
of the appliance, it is recommended
that the installation be carried out by
specialist personnel.
The manufacturer declines all responsibility
for damage caused by improper or
unworkmanlike installation.
Our policy is one of constant development
and improvement. Strict accuracy of
illustrations and specifications is not
guaranteed. Modification to design
and materials may be necessary
subsequent to publication.
Please read this handbook carefully
and keep it for future reference.
Before installing this appliance, you
may need to contact our Customer
Care Centre in order to purchase cer tain parts. Please see the details in the
Customer Service section of this hand book.
Before using the appliance for the
first time, remove all packaging and
protective polythene film.
Your first year Guarantee
To fulfil the conditions of your guarantee,
this appliance must be correctly
installed and operated, in accordance
with these instructions, and only be
used for normal domestic purposes.
Please refer to your guarantee card for
further details.
Please note that the guarantee, and
Service availability, only apply to the
UK and Republic of Ireland.
Installation
This appliance has been designed for
2
08 27114 00- CPLP
2/2/05
9:49 am
Page 5
Parts Identification
Figure 1
Viewed from
underneath
removable
grease filters
silder
motor
light
bulb
lamp covers
inner chimney
extension piece
outer chimney
extension piece
Outlet
adaptor
wall
bracket
adjustable
3
08 27114 00- CPLP
2/2/05
9:49 am
Page 6
Using the Hood
Important safety notes
A
0
1
2
3
T
B
C
D
E
F
Figure 2: hood controls:
The controls work as follows:
A - Neon light
B - Off
C - Position 1
D - Position 2
E - Position 3
F - Automatic stop timer
We recommend that you switch on the
hood for a few minutes before you
start cooking, and then leave it running
for approximately 15 minutes afterwards to ensure that all odours are
extracted.
•
Keep hob rings covered with pans
when switched on to avoid damaging the hood. The use of an
unprotected flame can cause a fire
hazard.
•
Do not flambé food underneath
the hood.
•
When frying foods, take care to
avoid cooking oil flares.
•
Wash the grease filters regularly refer to the cleaning section.
•
Do not check filters while the hood
is in use.
•
Do not touch the lamps after
prolonged use of the appliance.
Re-circulation method only:
To illuminate the cooking area underneath the hood, push the light control
button in to the “on” position. T o
switch off, press again to return to the
“off” position.
To operate the hood, press the button
for the required speed - select: 1 low,
2 medium, or 3 high speed. The
neon indicator light will light up to
show when the fan is operating. To
switch off, press the “off” button.
4
•
Keep the air ducting vents clear of
obstruction.
•
Change the carbon filters every 4
months.
08 27114 00- CPLP
2/2/05
9:49 am
Page 7
Care & Maintenance
Before cleaning or maintenance,
switch off the electricity supply.
4. Aluminium grease filters are
supplied with this appliance.
Outer casing
Replacing a light bulb
2. Remove the grease filters from the
hood.
All external parts of the outer casing
and visor can be safely cleaned with a
clean cloth wrung out in hot soapy
water.
3. Unscrew the bulb from the holder.
Replacement bulbs can be
obtained from your supplier or
local hardware store.
Do not use caustic pastes, abrasive
cleaning powders, wire wool and
hard implements, as they will damage
the surfaces.
4. Fit the new bulb, ensuring it is
screwed securely into the holder.
Carbon filters not supplied.
1. Switch off the electricity supply.
The carbon filters absorb cooking
odours and need renewing after about
4 months of normal use. A replacement carbon filter can be obtained
from your supplier.
5. Refit the grease filters.
Light bulbs are not covered by
the warranty
To avoid any fire risk, the following
cleaning instructions must be followed:
Saturation of the activated charcoal in
the filter will depend on how often the
hood is used, the type of kitchen and
the regularity of cleaning the grease filter.
Grease filters - aluminium
The grease filters absorb grease and
dust from cooking fumes, which would
otherwise damage the inside of the hood.
The carbon filters cannot be
washed - renew every 4 months.
1. Remove the grease filters from the
hood.
The grease filter should be removed
and cleaned regularly - with normal
use, this should be every 2 months.
2. Release the old carbon filters by
twisting them in either direction by a
quarter turn (90˚) until they disengage.
Important: Frequent washing is
essential to prevent a build up of
grease in the filters which could
become a fire hazard.
3. Fit the new carbon filters by
engaging them onto the pegs in
the centre of the fan grille and
twisting by a quarter turn until they
are gripped securely.
1. Remove the filters from the hood.
2. Carefully wash the grease filters in
hot soapy water and dry with a
clean towel.
4. Refit the grease filters.
3. Refit the clean filters.
5
08 27114 00- CPLP
2/2/05
9:49 am
Page 8
Installation
Regulations and standards
Mounting height
Before you start please read instructions
carefully. All installations, service and
repair work must be in accordance
with local standards and regulations.
The cooker hood must be fitted at least
650 mm above a gas or electric hob.
If cooker / hob instructions give a
different figure to that given above,
then the higher measurement should
be followed.
In the UK the regulations and standards
are as follows:-
To prevent possible hood cut-out, a
clearance of 650 mm is recommended
above gas hobs where possible.
1. Building regulations.
2. The current I.E.E. wiring regulations.
3. Electricity at work regulations.
4. Installation and servicing instructions
for this appliance.
Select method of operation
The cooker hood has two possible
methods of operation:
Ventilation
Method 1: Re-circulation requires
carbon filters.
Installation with dual filtration to clean
the air before it is re-circulated into the
room.
Adequate ventilation, in accordance
with the Gas Safety Regulations
(Installation and Use), and the relevant
building regulations must be provided
when the hood extracts air from a
room with a flued gas burning
appliance, which is not of the
“balanced flue” type.
Method 2: Extraction through an
outside wall requires a ducting kit.
The hood can be installed with a duct
to extract cooking fumes through an
outside wall.
Dimensions
Please note that all dimensions and
sizes are nominal, some variation is to
be expected.
6
08 27114 00- CPLP
2/2/05
9:49 am
Page 9
Installation
Method 1: Re-circulation (dual
filtration)
Assembly
The fan draws cooking fumes through
the washable grease filters into the
underside of the hood, then through
the carbon filter, to remove odours
before returning clean air to the
kitchen via the air ducting vents.
2. Fit the carbon filter (if supplied may be packed separately) by
engaging it onto the peg in the
centre of the fan grille and twisting
in either direction by a quarter turn
(90˚) until it is gripped securely.
If a cooker hood and any non
electrically powered appliances
extract fumes at the same time, then
the room must be suitably ventilated.
3. Discard the outlet adaptor as it is
not required when installing the
cooker hood as a re-circulation filter.
1. Remove the grease filters.
When selecting the best position for
the hood, ensure that air flow from the
air ducting vents is not obstructed by
cupboards, shelves, etc.
Do not vent into enclosed cupboard
space.
This method may require you to purchase carbon filters, these are available from our Customer Care Centre.
Please see the Customer Care section
of this handbook for further details.
7
08 27114 00- CPLP
2/2/05
9:49 am
Page 10
Installation
Method 2: Extraction through
an outside wall
Wall vent kit and ducting
The fan draws cooking fumes through
the washable grease filter into the
underside of the hood, then the fumes
are expelled through a duct or directly
through an outside wall.
This method may require you to contact our Customer Care Centre to purchase a ducting kit. You may however prefer to use your existing ducting,
if it is appropriate.
Figure 3
•
For connecting the hood outlet
adaptor to the outside wall, we
recommend that a wall vent kit is
purchased from your supplier or
local hardware store.
•
Use a 125 mm diameter ducting
kit and connect to the ducting
outlet adaptor.
•
Horizontal duct runs should be
avoided. A slope of 5˚ or more
upwards from the hood to the wall
outlet will assist the flow of air.
•
The ducting pipe and any connecting
pieces should be coupled to the
preceding piece by pushing into
and never over it - the upper part
must be fitted over the lower part.
•
The outlet from the hood must not
be ducted into a wall cavity,
through a ventilator shaft or
through a chimney. It must not be
ducted through a flue used by a
non-electrically powered appliance.
•
Adequate ventilation must be
provided if a cooker hood extracts
fumes from the room at the same
time as an appliance powered by
a fuel other than electricity (such
as a gas appliance) is operated.
The extractor hood removes air
from the room which the burner is
dependant on for combustion.
Assembly
1. Remove the grease filters.
2. Remove the carbon filter (if fitted)
and discard, as this is not required
when installing the cooker hood as
an extractor fan.
3. Connect the discharging pipe to
the ducting outlet adaptor, and
route the pipe through a 130 mm
hole in the rear wall.
8
08 27114 00- CPLP
2/2/05
9:49 am
Page 11
Installation
Wall fixing (figures2,3,4)
•
Drill the holes A, as per the dimensions in fig 2.
•
Using the screws and dowels
supplied with the appliance, fasten
the wall bracket to the wall.
•
Ensure that they are suitable for the
type of wall where the cooker
hood is to be mounted.
•
Locate and fasten the hood to the
wall. Secure the body of the hood
as shown in fig 4.
•
Secure the top junction piece to
the wall bracket through the side
holes using the screws provided
see fig 3.
Securing the telescopic flue.
• Make sure the the power cables
are inside the decorative flue to
conceal them.
• Make sure there is an exhaust
opening prepared.
• Adjust the width of the support
bracket (fig 3), then fix it into the
ceiling using the screws shown in
fig 3 - A. This should be as shown
in fig 2.
• Connect the flange as per fig 4.
Then insert the two pieces of the
flue.
• In some cases it may be necessary
to adjust the length of one or both
of the chimney sections. Cut the
bottom of each section so that the
cut is hidden using suitable cutting
implements. Please take care not
to obstruct the ducting vents.
9
08 27114 00- CPLP
2/2/05
9:49 am
Page 12
Installation
Re-circulation mode only
• Since the side vents are located in
the upper chimney section, no
L-shaped air flow directing piece is
required.
Hood Measurements
The below table shows the various
hood measurements for this hood.
The dimensions of the chimney piece
(including the hood body) are as follows:
600CPLP & 1100CPLP
250mm x 183mm x 330 - 700mm
900CPLP & 1000CPLP
250mm x 183mm x 605 - 650mm
This is W x D x H.
Body of hood
Width
mm
Depth
mm
Height
mm
600CPLP
600
492
260
900CPLP
900
492
260
1000CPLP
1000
492
260
1100CPLP
1100
492
260
Hood Name
10
08 27114 00- CPLP
2/2/05
9:49 am
Page 13
Installation
Electrical connection
Figure 6
This appliance is double insulated for
safety and therefore does not require
an earth connection to the mains inlet.
The wires in the mains lead are
coloured in accordance with the
following code:
Blue = neutral, Brown = live.
As the colours of the wires in the
mains lead for the appliance may not
correspond with the coloured markings
identifying the terminals in your spur
box, proceed as follows:
1. The wire which is coloured blue
must be connected to the terminal
marked N (neutral) LOAD, or
coloured black.
2. The wire which is coloured brown
must be connected to the terminal
marked L (live) LOAD, or coloured
red.
The fused spur socket should be
positioned where is is easily accessible
so you can switch off the supply to the
hood when renewing the light bulb.
11
08 27114 00- CPLP
2/2/05
9:49 am
Page 14
Technical Data
Electricity supply
230 - 240V ~ 50Hz
Grease filters
x 2 metal filters
Note:
After cleaning grease filters may lose
their colour slightly - this does not
affect their performance.
Classification
class II metal encased
Noise level (External Venting)
Position 3
56 dBA
Position 2
51 dBA
Position 1
48 dBA
Extraction Rate (External)
Position 2
440m3/H
378m3/H
Position 1
303m3/H
Position 3
Noise Level (Internal Venting)
Position 3
59 dBA
Position 2
56 dBA
Position 1
53 dBA
Extraction Rate (Internal)
Position 2
301m3/H
259m3/H
Position 1
227m3/H
Position 3
Light bulbs
600CPLP : 2 x 40W
900CPLP: 2 x 40W
1000CPLP: 2 x 20W Halogen
1100CPLP: 3 x 20W Halogen
Please make sure you follow the
instructions for replacing light bulbs
carefully and always make sure you
use the correct bulb type.
Motor rating
120W
Carbon filters
x 2 - available as Spares
12
08 27114 00- CPLP
2/2/05
9:49 am
Page 15
Customer Care & Service
Please keep this handbook in a safe place as the information inside may be of
use should you sell, or pass on the appliance. Please fill in the model number
and serial number in the spaces provided below as they will assist us should you
need to call.
0870 444 9929
When you dial this number you will hear a recorded message and be given a
number of options. This indicates that your call has been accepted and is being
held in a queue. Calls are answered in strict rotation as our Customer Care
Representatives become available.
Opening Hours for Customer Care
Monday to Friday 8am - 8pm
Saturday 8.30am - 6pm
Sunday 10am - 4pm
Enter appliance numbers here for future reference:
Model No
Serial No
Please ensure you have the above details (Model No and Serial No) to hand
when calling Stoves Customer Care. They are essential to booking your call, or
ordering any spare parts.
Spares for this appliance:
Carbon Filters - 082611471
Ducting Kit 1m - 082611309
Ducting Kit 3m - 082611310
Outside the UK and Northern Ireland, refer to your local supplier.
13
08 27114 00- CPLP
2/2/05
9:49 am
Page 16
Splashback (if purchased)
Installation
1.
2.
3.
Fix the 2 top hanging screws to the dimensions indicated see below.
Hang the backplate on the 2 top hanging screws.
Secure the backplate with screws through the bottom 2 fixing holes
15.6mm
750 mm
15.6mm
1000 mm
Care & Cleaning
Only use a clean cloth wrung out in hot soapy water, and dry with a soft cloth. Stubborn
marks can be removed using warm soapy water. We recommend that you clean the whole
of the splashback to maintain a uniform finish.
Do not use undiluted bleach or any products containing chlorides as they can permanently
damage the splashback.
Extra care should be taken when cooking food in salted water. Some foods are corrosive
eg; vinegar, fruit juices and especially salt - they can mark or cause damage if they are left
on the surface. Wipe any splashes immediately.
Customer Support
In case of difficulty, please call Stoves Customer Support Helpline on
0870 444 9929
14
08 27114 00- CPLP
2/2/05
9:49 am
Page 17
15
08 27114 00- CPLP
2/2/05
9:49 am
Page 18
08 27114 00- CPLP
2/2/05
9:49 am
Page 19
08 27114 00- CPLP
2/2/05
9:49 am
Page 20
STONEY LANE, PRESCOT, MERSEYSIDE, L35 2XW
08 27114 00 © 2004
Download PDF
Similar pages
Specifications
LA-Tel Installation Instructions
For Commercial & Residential Applications
Jenn-Air CVGX2423 User's Manual
Best Shelf
Best Surf
Britannia Brioso 100cm
Best Fusion
Best Latina
New World CHIM60B