Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail: saleshelp@tripplite.com
Model #: SU16000RT4U
SmartOnline 16kVA On-Line Double-Conversion UPS, 8U Rack/Tower, 208/120V or 240/120V Hardwire+NEMA
outputs, Split phase input
Highlights
16kVA / 16,000VA / 11,200W on-line double-conversion UPS, split phase input
208/120V or 240/120V +/-3% output at 60Hz
8U Rack/Tower compatible; Hot-swappable power and battery modules
USB, RS232 & EPO ports; support for SNMP/WEB card options
Front panel LEDs with detailed LCD monitoring and control screen
Expandable runtime with optional external battery packs
Hardwire input (4 wire split phase); L6-30R, C19 & 5-15/20R outlets
Description
Tripp Lite 16kVA SmartOnline Hot-Swappable Modular Rack/Tower UPS offers 16,000 VA on-line, double-conversion UPS support for server,
network and telecommunications equipment. Maintains battery-derived AC output during blackouts with active, full-time power conditioning.
Fault-tolerant auto-bypass prevents unexpected service interruptions during overload or internal fault conditions. 4U power module and 4U external
battery pack installs in 8 rack spaces (8U). Upright tower installation supported with optional accessories. Maintains full-time sine wave output within
3% of selectable 208/120 or 240/120V AC. Corrects brownouts and overvoltages from 65V to 140V (L-N). Expandable runtime with optional external
battery packs. Converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC output with enhanced protection
from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Highly efficient
operation in optional economy mode setting, saving BTU heat output and energy costs. Network-grade AC surge and noise suppression. Network
management interfaces include combination DB9 RS-232 enabled and dry contact serial port, enhanced USB port and SNMPWEBCARD slot.
HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports
simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces. Includes PowerAlert
monitoring software and complete cabling. Supports Emergency Power Off (EPO) via built-in interface. Front panel LEDs and LCD readout with
scroll controls support visual monitoring of all major UPS functions. LED/LCD display panel easily rotates for viewing in rackmount or tower
configurations. Split phase 4 conductor hardwire input and output supported. UPS supported outlets include two L6-30R, six C19 and 5 low voltage
5-15/20R. Output connections are mounted on a detachable backplate with manual bypass switch to enable hot-swappable UPS replacement without
powering off connected equipment. External battery packs are field replaceable and hot swappable. Attractive all-black color scheme. $250,000
connected equipment insurance;
Package Includes
16kVA/16,000 VA UPS power module in 4U rackmount housing
Detachable hardwire input/output and output receptacle PDU
External 4U battery pack
4 post rackmount installation brackets
Features
True online, double-conversion UPS provides pure, full-time sine wave AC output free of surges, voltage fluctuations and line noise
16,000 VA/11,200 watt output power capacity with dual voltage output of 208/120 or 240/120V
16,000 VA/11,200 watt output power capacity with dual voltage output of 208/120 or 240/120V
4U high power density power module and 4U external battery pack supports rackmount installation in 8 rack spaces
Dual conversion UPS actively converts raw input from AC to DC, then back to perfect sine wave AC output with enhanced protection from
harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
Hardwire input terminals, hardwire output and output receptacles are mounted on a detachable backplate with manual bypass switch to
enable hot-swappable UPS replacement without powering off connected equipment
Provides perfectly regulated, sine wave output power free of line noise, transient surges and frequency variation for the most efficient
operation of critical servers, networking and telecommunications equipment
Maintains output within 3% of selected 208/120 or 240/120V nominal voltage during brownouts and overvoltages
Supports connected equipment during blackouts for 12/5 minutes at half/full load levels, runtime is further expandable with optional external
BP192V18-4U battery packs
Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
Network interfaces support simultaneous communications via DB9 port, USB port and SNMPWEBCARD slot. DB9 port supports RS-232
and dry contact messaging. HID-compliant USB interface enables integration with built-in power management and auto shutdown features
of Windows and Mac OS X.
Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus
any number of additional servers over IP
Communications ports support on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge
current, battery capacity, AC line frequency, timed inverter shutoff, activate self-test and output power control
Built-in Emergency Power Off (EPO) interface with cable
Includes 13 output receptacles (2 L6-30R, 6 C19, 5 NEMA 5-15/20R) plus hardwire output, all of which are available for simultaneous use
Split phase, 4 conductor hardwire input connection (featured on included detachable PDU).
Front panel LEDs and LCD readout with scroll button enables visual confirmation of all major UPS functions and current site electrical
conditions
Front panel switches enable power on/off control, self-test and alarm cancel functions
Included adjustable mounting rails support installation in 4 post 19 inch rack enclosures
Optional 2-9USTAND set of tower stands supports upright tower installation
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
$250,000 Ultimate Lifetime Insurance (USA and Canada Only)
Specifications
OUTPUT
Output Volt Amp
Capacity (VA)
16000
Output kVA capacity
(kVA)
16
Output Watt Capacity
(watts)
11200
Output kW capacity
11.2
Output power factor
0.7
Output Capacity
Details
16,000 VA (240V) / 13,860 VA (208V) / 11,200 watts (208/240V)
Crest Factor
3:1
Nominal Output
Voltage(s) Supported
120V; 208V; 240V
Nominal Voltage
details
240/120V or 208/120V split phase output
Frequency
compatibility
60 Hz
Output voltage
regulation (line mode)
+/- 3%
Output voltage
regulation (Economy
line mode)
+/- 10%
Output voltage
regulation (Battery
mode)
+/- 3%
Built-in UPS output
receptacles
5 5-15/20R outlet(s); 2 L6-30R outlet(s); 6 C19 outlet(s); Hardwire
Output circuit breaker
20A branch rated double pole breakers (x3) protect 2 C19 and 1 5-15/20R outlets each, 30A branch rated double
pole breakers (x2) protect 1 L6-30R outlet each, 20A single pole breakers (x2) protect one 5-15/20R outlet each
Output AC waveform
(AC mode)
Sine wave
Output AC waveform
(battery mode)
Pure Sine wave
INPUT
Rated input current (at
maximum load)
68A
Nominal Input
Voltage(s) Supported
208V AC / 120V AC (4 wire split single phase); 240V AC /120V AC (4 wire split single phase)
UPS input connection
type
Hardwire
UPS input connection
description
4 wire split-phase input (L1, L2, N, G)
Recommended
Electrical Service
70A 208/240-120 Split Phase
BATTERY
Full load runtime
(minutes)
5 min. (11,200w)
Half load runtime
(minutes)
12 min. (5600w)
Expandable battery
runtime
Supports extended runtime with optional external battery packs
External battery pack
compatibility
BP192V18-4U; BP192V557C-16K; BP192V787C-16K; BP192V1037C-16K; BP192V1407C-16K
DC system voltage
(VDC)
192
Battery recharge rate
(included batteries)
Less than 6 hours from 10% to 80%
Battery replacement
description
Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation
description
Online, double-conversion power conditioning
Overvoltage correction
3% output voltage regulation during overvoltages to 140 (measured L1-N : L2-N)
Undervoltage
correction
3% output voltage regulation during undervoltages to 65 (measured L1-N : L2-N)
LEDS ALARMS & SWITCHES
LED Indicators
6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD
screen offers additional information and control options
Alarms
Unique audible alarms for all major UPS, environmental and power conditions (see manual)
Alarm cancel operation
Alarm cancel switch
Switches
2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and
execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module
replacement
SURGE / NOISE SUPPRESSION
UPS AC suppression
response time
Instantaneous
EMI / RFI AC noise
suppression
Yes
PHYSICAL
Installation form
factors supported with
included accessories
4 post 19 inch rackmount (mounting rail kit included)
Included mounting
accessory description
2 sets of adjustable 4 post rack rails included
Installation form
factors supported with
optional accessories
2 post rackmount (2POSTRMKITWM); Tower (2-9USTAND)
Optional mounting
accessory notes
2 sets of 2POSTRMKITWM required for 2 post rackmount installation of separate power module and battery pack
Primary form factor
Rackmount
UPS / Power Module
dimensions in primary
form factor (height x
width x depth / inches)
7 x 17.5 x 40.5
UPS / Power Module
dimensions in primary
form factor (height x
width x depth / cm)
17.8 x 44.4 x 102.9
Installed whole
system maximum
rack depth (inches)
40.5
Installed whole
system maximum
rack depth (cm)
102.9
Installed whole
system total rack
space height (rack
spaces)
8U
Secondary form factor
Tower (requires 2-9USTAND)
UPS / Power Module
weight (lbs)
86
UPS / Power Module
weight (kg)
39
UPS dimensions
details
Includes 4U power module and 4U battery pack
Included battery pack
dimensions (height x
width x depth / inches)
7 x 17.5 x 27.8
Included battery pack
dimensions (height x
width x depth / cm)
17.7 x 44.4 x 70.6
Included battery pack
weight (lbs)
239
Included battery pack
weight (kg)
108.5
UPS Shipping
dimensions (height x
width x depth / inches)
45.5 x 23.5 x 34.3
UPS Shipping
dimensions (height x
width x depth / cm)
115.6 x 59.7 x 87.1
Shipping weight (lbs)
448.8
Shipping weight (kg)
203.8
UPS housing material
Steel
Cooling method
Fan
ENVIRONMENTAL
Operating
Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
Storage Temperature
Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
Relative Humidity
0 to 95%, non-condensing
AC mode BTU / hr.
(full load)
5690.1
Battery mode BTU /
hr. (full load)
4231.1
Operating Elevation (ft)
0-3000m (0 to 10,000 ft.)
Audible Noise
60 dBA at front side 1 meter
Operating Elevation
(m)
0-3000 m
COMMUNICATIONS
Communications
interface
USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
Network monitoring
port description
RS232 and contact closure communications are supported on one DB9 port
PowerAlert software
Included
Communications cable
USB and DB9 cabling included
LINE / BATTERY TRANSFER
Transfer time
No transfer time (0 ms.) in online, double-conversion mode
Low voltage transfer
to battery power
(setpoint)
65V (L1-N:L2-N)
High voltage transfer
to battery power
(setpoint)
140V (L1-N:L2-N)
SPECIAL FEATURES
Cold Start (startup in
battery mode during a
power failure)
Cold-start operation supported
High availability UPS
features
Automatic inverter bypass; Manual bypass switch; Detachable hot-swap PDU; Hot swappable UPS power module;
Hot swappable batteries
Green & high
efficiency features
High efficiency economy mode operation; Schedulable daily hours of economy mode operation
CERTIFICATIONS
UPS Certifications
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
WARRANTY
Product Warranty
Period (Worldwide)
2-year limited warranty
Related Items
Optional Products
Related Model
Description
Qty.
SNMPWEBCARD
For remote monitoring and control via SNMP, Web, or Telnet.
1
ENVIROSENSE
Monitors temperature, humidity and contact-closure inputs. (Requires SNMPWEBCARD
or switched PDU.)
1
SRSWITCH
Magnetic Door Switch Kit for front and rear doors; requires ENVIROSENSE
1
BP192V18-4U
BP192V18-4U - External Battery Pack for UPS System
1
WEXT3-SU16-20K
3-Year Warranty (1-Year Extension) - For SU16K through SU20K Single-Phase UPS
Models
1
WEXT5-SU16-20K
5-Year Warranty (3-Year Extension) - For SU16K through SU20K Single-Phase UPS
Models
1
2-9USTAND
Enables Tower Placement of Rackmount UPS Systems
1
2POSTRMKITHD
Enables 2-Post Rackmount Installation of 3U and Larger UPS, Transformer and Battery
Pack Components
1
PDUMV20
Single-Phase Metered PDU, 20A 120V, 0U Vertical Rackmount, NEMA 5-15/20R outlets,
NEMA L5-20P input with 5-20P adapter
1
PDUMV40
Single-Phase Metered PDU, 20A 120V with dual 20A circuits, 0U Vertical Rackmount,
NEMA 5-15/20R outlets, set of two NEMA L5-20P inputs and 5-20P adapters
1
PDUMV20HV
Single-Phase Metered PDU, 20A 200-240V, 0U Vertical Rackmount, C19 & C13 outlets,
C20 inlet with NEMA L6-20P input cable
1
PDUMV30HV
Single-Phase Metered PDU, 30A 208/240V, 0U Vertical Rackmount, C19 & C13 outlets,
NEMA L6-30P input plug
1
PDUMNV20
Single-Phase Monitored PDU, 20A 120V, 0U Vertical Rackmount, NEMA 5-15/20R
outlets, NEMA L5-20P input with 5-20P adapter
1
PDUMNV20HV
Single-Phase Monitored PDU, 20A 200-240V, 0U Vertical Rackmount, C13 & C19
outlets, C20 inlet with NEMA L6-20P input cable
1
PDUMNV30HV
Single-Phase Monitored PDU, 30A 208/240V, 0U Vertical Rackmount, C13 & C19
outlets, NEMA L6-30P input plug
1
PDUMV20HVNET
Single-Phase Switched PDU, 20A 200-240V, 0U Vertical Rackmount, C13 & C19 outlets,
C20 inlet and NEMA L6-20P cable
1
PDUMV30HVNET
Single-Phase Switched PDU, 30A 208/240V, 0U Vertical Rackmount, C13 & C19 outlets,
NEMA L6-30P input plug
1
AS400CABLE KIT
Power Management Tools - UPS Communication Cable Kit for System i / AS400 /
iSeries Servers
1
MODBUSCARD
For remote monitoring and control via MODBUS protocol
1
P036-006
6-ft. 12AWG Heavy Duty Power cord (IEC-320-C19 to IEC-320-C20)
1
P041-001-2
1-ft. 10AWG Heavy Duty Power Splitter Cable (NEMA L6-30P to 2x NEMA L6-30R)
1
More information, including related products, owner's manuals, and additional technical specifications, can be found online at
www.tripplite.com/en/products/model.cfm?txtModelID=3652.
Copyright © 2012 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous
improvement. Specifications are subject to change without notice. Photos may differ slightly from final products.