Gas Stoves
C34-10 Direct Vent Gas Stove
Model
C34-NG10
Fuel Type
C34-LP10
Natural Gas
Propane
Minimum Supply Pressure
5.0” W.C. (1.25 kPa)
12.0” W.C. (3.00 kPa)
Manifold Pressure - High
3.8” W.C. (0.95 kPa)
11” W.C. (2.74 kPa)
Manifold Pressure - Low
1.1” W.C. (0.27 kPa)
2.9” W.C. (0.72 kPa)
Orifice Size
Minimum Input
Maximum Input
Vent Sizing
#36
#52
16,000 BTU/h
16,000 BTU/h
32,000 BTU/h
32,000 BTU/h
4” Inner / 6-5/8” Outer
4” Inner / 6-5/8” Outer
Approved Venting Systems
FPI AstroCap™ Flex Vent
Simpson Direct Vent Pro®
American Metal Products® Amerivent Direct
Security Secure Vent®
Selkirk Direct-Temp™
Metal-Fab® Sure Seal
Back wall
B
C
A
A
Side wall
Rigid Pipe Vent Systems:
Side wall
Flex Vent Systems:
D
Side wall
E
F
E
Back wall
F
C34 Clearances to Combustibles
Dimension
Description
C34
A
Side Wall to Unit
10” (250mm)
B
Back Wall to Unit
6” (150mm)
C
Back wall to Vent Center line
13” (559mm)
D
Side wall to Vent Center line
22” (330mm)
Dimension
Description
E
Side wall to unit
1.5” (38mm)
F
Side wall to Vent Center line
14” (356mm)
Corner Clearances
C34
Minimum ceiling height is 36" (914mm) from top of unit.
Minimum clearance to vent is 1-1/4” (32mm).
The above listed clearances are minimum distances to combustible
materials. When installing on carpet or vinyl flooring the bottom pedestal
cover plate must be installed.
Gas Stoves
C34-10 Gas Stove
Regency Direct Vent System
Snorkel Terminations
These venting systems, in combination with the C34 Direct Vent Gas
Fireplace, have been tested and listed as a direct vent heater system
by Warnock Hersey. The location of the termination cap must conform
to the requirements in the Vent Terminal Locations diagram.
Snorkel Terminations:
For installations requiring a vertical rise on the exterior of the building,
14-inch and 36-inch tall Snorkel Terminations and the Riser Vent are
available. Follow the same installation procedures as used for standard
Horizontal Termination. NEVER install the snorkel upside down.
Horizontal Terminations Only
FPI Direct Vent (Flex) System Termination Kits include all the parts
needed to install the C34 using a flexible vent.
Contains:
#946-116
2 Feet
1. 6-5/8” Rigid Pipe Section (Kit length)
2. 4” flexible liner (Kit length)
3. spring spacers (4)
4. 90° Elbow
5. Adjustable pipe section 13-1/2” to 24”
6. thimble cover (1)
7. thimble (1)
8.adapter
9. AstroCap termination cap (1)
10. trim collar (2)
11. tube of Mill Pac (1)
12. S.S. screws #8 x 1-1/2”, self-tap, (12)
13. Blk. screws #8 x 1-1/2”, self-tap, (14)
14. Blk. screws #8 x 1-1/2” drill point, (4)
15. S.S. screws #8 x 1-1/2” drill point, (4)
16. Wood screws #8 x 1” (8)
#946-216
4 Feet
Dura-Vent
Snorkel
Min. 12"*
(305mm)
Notes:
1. Liner sections should be continuous without VNT-SNR1.EPS
any joints or seams.
2. Only Flex pipe purchased from Regency may be used for Flex
installations.
3. Horizontal sections must be supported every 3 feet.
Dura-Vent
Snorkel
Dura-Vent
Snorkel
Dura-Vent
Snorkel
Min. 12"*
(305mm)
Min. 12"*
(305mm)
Dura-Vent
Snorkel
Dura-Vent
Snorkel
Window
Well
VNT-SNR1.EPS
VNT-SNR1.EPS
Adequate
drainage
Min. 12"*
(305mm)
Min. 12"*
(305mm)
Length
Min. 12"*
(305mm)
FPI Kit #
Window
Well
Window
Well
Adequate
drainage
Adequate
drainage
Gravel
Gravel
VNT-SNR2.EPS
VNT-SNR2.EPS
Gravel
Below Grade Snorkel Installation
If the Snorkel Termination must be installed below grade, i.e. basement
application, proper drainage must be provided to prevent water from
VNT-SNR2.EPS
entering the Snorkel Termination.
Refer to Rigid Pipe Installation
Riser Vent
instructions for details. Do not attempt to enclose the Snorkel
within
the
Termination
Riser Vent
Termination
wall, or any other type of enclosure.
Riser Vent
Termination
Min. 6-1/4"*
(159mm)
Min. 6-1/4"*
(159mm)
Min. 6-1/4"*
(159mm)
VNT-SNR3.EPS
VNT-SNR3.EPS
Alternate Horizontal
Termination Caps
VNT-SNR3.EPS
Alternate:
Horizontal
Riser Vent
Terminal
Part# 640-530/P
Gas Stoves
Vent Restrictor Position
Vent restriction is required for certain venting installations, see the
diagrams in "Venting Arrangement" section to determine if they are
required for your installation.
The vent restrictor has three settings: "C" Center (factory setting), "L"
Left, and "R" Right. Simply loosen the screws and push the vent restrictor
plate to the correct position. Tighten the screws.
Rigid Pipe Venting Systems
Horizontal or Vertical Terminations
Vertical
Termination
Cap
Storm Collar
Vinyl Siding
Standoff (Optional)
Flashing
Horizontal
Termination Cap
# 946-523/P
Ceiling Firestop
Wall Thimble
Pipe Length
Adj.Pipe Length
11" - 14-5/8"
o
90 Elbow
24" Pipe
Length
Gas Stoves
C34-10 Gas Stove
Venting Arrangements - Vertical Terminations
Rigid Pipe System
(Propane & Natural Gas)
The C34 is approved for a maximum 30 ft. straight vertical, with Rigid
Pipe vent systems for Propane and Natural Gas.
The shaded area in the diagram (right) shows allowable venting
configurations with a maximum of two 45° elbows allowed. Terminations
falling in the shaded area must have the Vent Restrictor Position set
to “R” Right.
•
•
•
•
•
Vent must be supported at offsets.
Horizontal sections must be supported every 3 feet
Firestops are required at each floor level and whenever
passing through a wall.
Maintain clearances to combustible materials.
Minimum of 1’ pipe section between elbows.
VENTING ARRANGEMENTS
VERTICAL TERMINATION SYSTEMS FOR
RESIDENTIAL MANUFACTURED AND MOBILE HOMES
The shaded area in the diagram below shows all allowable
combinations of straight vertical and offset to vertical runs with
vertical terminations. Maximum two 45o elbows.
All vertical and offset to vertical vent installations require Vent Restrictor
Position "R" (Right). If the vent is ENCLOSED in a chase (min. size 9" x
9") maintain a 1-1/4" clearance to combustibles.
May be installed in Manufactured (Mobile) Homes after first sale.
Vertical Venting with Two (2. 90° Elbows
Two 45° elbows = One 90° elbow
Option
V
H
V+ V1
A)
1’ Min.
4’ Max.
2’ Min.
B)
2’ Min.
5’ Max.
3’ Min.
C)
3’ Min.
6’ Max.
4’ Min.
D)
4’ Min.
7’ Max.
5’ Min.
E)
5’ Min.
8’ Max.
6’ Min.
Maximum total pipe length, of
all sections, must not exceed
30 feet.
Total horizontal sections must
not exceed 8 feet.
Minimum of 1 foot between
90° elbows is required.
Vent Restrictor in position “C” (Center),
Straight Vertical and Offset to Vertical Terminations
use Vent Restrictor Position "R" (Right)
Gas Stoves
VENTING ARRANGEMENTS
HORIZONTAL TERMINATIONS FOR ALL
VENTING SYSTEMS
The shaded areas in the diagram below show all allowable
combinations of vertical runs with horizontal term-inations.
Maximum one 90O elbow (two 45o elbows equal one 90o elbow).
Propane and Natural Gas: Residential, Manufactured and Mobile Homes Installations
The venting arrangements diagrammed below, have a min. of 75% (flue
loss) efficiency with Fan Off, as required for manufactured homes. (Actual
efficiency may be as high as 85%)
May be installed in Manufactured (Mobile) Homes after first sale.
C34-10 Gas Stove
Horizontal Venting with Two (2. 90° Elbows
Two 45° elbows = One 90° elbow
Option
V
H + H1
A)
4’ Min.
6’ Max.
B)
5’ Min.
7’ Max.
C)
6’ Min.
8’ Max.
Maximum total pipe length, of all
sections, must not exceed 30 feet.
Total horizontal sections must not
exceed 8 feet.
Minimum of 1 foot between 90°
elbows is required.
Vent Restrictor in position “C” (Center).