ADHESIVE QUICK CHECK CHART
TYPE OF SUBFLOOR
CONCRETE (1)
(All grades)
CONCRETE (2)(3)
(Chemically treated)
CONCRETE
(Radiant Heated)
PLYWOOD
(Construction grade)
Existing Resilient Flooring (4)
Metal, Ceramic, Terrazzo (5)
PARTICLE BOARD (6)
Mohawk Rubber Tiles and
Medi-Flex Sheets
AD-777
AD-535
Consult Remediation
Systems document
AD-535
AD-777
AD-535
AD-535
AD-535
N/R
Medi-Flex TRUE Tiles and
Sheets
AD-777
AD-535
Consult Remediation
Systems document
AD-535
AD-777
AD-535
AD-535
AD-535
N/R
Luxury Vinyl Tile and
Ultimate Step
PVC-FREE:
- Stonewalk
ACCESSORIES
Commercial Rubber
Treads
Note: For demanding applications such as underneath patients’ beds, OR’s, ER’s, use AD-530SF and consult your representative for details.
PS-30 (DS-100)
AD-610
AD-535
AD-610
Consult Remediation
Systems document
AD-535
PS-30 (DS-100)
AD-610
AD-535
AD-535
AD-535
N/R
Consult Remediation
Systems document
N/R
AD-610
N/R
N/R
N/R
Concrete Steps
Plywood Steps
Existing Resilient Steps
Metal, Ceramic, Terrazzo
Steps
PARTICLE BOARD
AD-535, AD-777
AD-535, AD-777
N/R
AD-535
N/R
ACTIVE TEC CAN BE USED ON ANY SUBFLOOR TYPE EXCEPT ON WAFER, FLAKE, CHIP, PARTICLE OR SIMILAR BOARDS, FLOOR IMPERFECTIONS MUST BE CORRECTED PRIOR TO INSTALLATION
WHEN MORE THAN ONE ADHESIVE IS RECOMMENDED, REFER TO PRODUCT INSTALLATION INSTRUCTIONS FOR SELECTION, AS IT DEPENDS ON SITED CONDITIONS.
MOISTURE AND pH TESTS MUST BE CONDUCTED AS PER ASTM RECOMMENDATION, AND MUST COMPLY WITH SPECIFICATIONS LISTED IN PAGE 3.
(1)
(2)
(3)
(4)
(5)
(6)
MOISTURE MEMBRANE IN GOOD WORKING CONDITION MUST BE INSTALLED UNDER ON AND BELOW GRADE CONCRETE SLABS; MOHAWK GROUP IS NOT RESPONSIBLE FOR HYDROSTATIC PRESSURE THAT MAY OCCUR IN THE FUTURE.
CONCRETE SLABS WITH TOPICAL OR ADD-IN ADDITIVES, SUCH AS BUT NOT LIMITED TO, CURING AGENTS, SURFACE HARDENER, SEALERS, COATING MUST BE REMEDIATED BEFORE INSTALLATION.
REMEDIATION SYSTEMS DOCUMENT CAN BE FOUND ON MOHAWK GROUP WEB SITE.
ALTHOUGH OUR PRODUCTS AND ADHESIVES CAN BE USED OVER EXISTING RESILIENT FLOORING, MOHAWK GROUP RECOMMENDS THAT EXISTING FLOORING BE REMOVED; MOHAWK GROUP WILL NOT HONOR ANY CLAIM RELATING TO
BOND FAILURE.
GLAZINGS, FINISHES, WAXES AND SEALERS MUST BE REMOVED AND SURFACE ROUGHENED PRIOR TO INSTALLATION.
NOT RECOMMENDED (N/R) ON SUBFLOORS SUCH AS, BUT NOT LIMITED TO, WAFER, FLAKE, CHIP, PARTICULE BOARDS; SOFT WOOD, PLYWOOD OTHER THAN CONSTRUCTION GRADE.
Mohawk Group, 1975 West Oak Circle, Marietta GA, 30062
Phone: 800-554-6637
Customer Service 877-235-0453
Customer Service Fax 877-244-8054
Samples 888-740-6936
Installation / Maintenance 800-833-6954
Website : www.mohawkgroup.com
6016-M (2015-05-19)
Page 1 of 4
ADHESIVE QUICK CHECK CHART
ADHESIVES
TROWEL SPECIFICATION (1)
APPROXIMATE COVERAGE (2)
Acrylic Pressure-Sensitive Adhesive
0.8 mm x 1.6 mm x 0.8 mm (1/32 x 1/16 x 1/32) U-notched trowel
Up to 23.2 sq. m / 3.79 liter unit (up to 250 sq. ft. / U.S. gallon)
AD-33
Solvent-Free Epoxy Stair Nosing Caulking
For concrete, wood or metal
Up to 15.0 lin. m / 6 mm bead (up to 50 lin. ft. / ¼” bead)
AD-777
Acrylic PSA/Wet-Set Adhesive
0.8 mm x 1.6 mm x 0.8 mm (1/32 x 1/16 x 1/32) U-notched trowel
Up to 22.74 sq. m / 3.79 liter unit (up to 245 sq. ft. / U.S. gallon)
AD-535
Solvent-Free Epoxy Adhesive
0.8 mm x 1.6 mm x 0.8 mm (1/32 x 1/16 x 1/32) U-notched trowel
Up to 18.6 sq. m / 3.79 liter unit (up to 200 sq. ft. / U.S. gallon)
AD-610
Acrylic Wet-Set Adhesive
0.8 mm x 1.6 mm x 0.8 mm (1/32 x 1/16 x 1/32) U-notched trowel
Up to 18.3 sq. m / 3.79 liter unit (up to 200 sq. ft. / U.S. gallon)
Durabond
Cold welding system for rolled rubber
50 ml (1.7 fl oz) cartridge
Up to 12.2 lin. m / cartridge (up to 40 lin. ft. / cartridge)
PS-30
(DS-100)
(1)
(2)
TROWEL SPECIFICATION CODE: DEPTH / WIDTH / SPACING
THIS IS AN ESTIMATE ONLY; ACTUAL COVERAGE DEPENDS ON CONCRETE POROSITY, TROWEL CONDITION AND SITE TEMPERATURE.
Mohawk Group, 1975 West Oak Circle, Marietta GA, 30062
Phone: 800-554-6637
Customer Service 877-235-0453
Customer Service Fax 877-244-8054
Samples 888-740-6936
Installation / Maintenance 800-833-6954
Website : www.mohawkgroup.com
6016-M (2015-05-19)
Page 2 of 4
ADHESIVE QUICK CHECK CHART
MOISTURE & pH LEVELS SPECIFICATIONS FOR ADHESIVES ON ALL GRADES
•
•
•
•
•
•
•
•
•
pH TEST
ASTM F 710
5.3.1
ANHYDROUS CALCIUM CHLORIDE TEST
ASTM F 1869
RELATIVE HUMIDITY TEST
ADHESIVES
Moisture vapor emission must not exceed stated amount
below in
Relative Humidity (RH) must not exceed
Amount listed below (%)
Test
Procedure
5.3.1
PS-30 (DS-100)
0 – 2.26 kg (0 - 5.0 lbs)
80%
8 -10
AD-33
0 - 1.36 kg (0 - 3.0 lbs)
80%
8 -10
AD-777
0 - 2.26 kg (0 - 5.0 lbs)
80%
8 -10
AD-535
0 – 2.26 kg (0 - 5.0 lbs)
85%
8 -10
AD-610
0 – 2.26 kg (0 - 5.0 lbs)
80%
8 -10
Good quality rubberized asphalt emulsion
adhesive
0 – 2.26 kg (0 – 5.0 lbs)
75%
8 -10
kg / 100 sq. m / 24 hours (lbs / 1,000 sq. ft. / 24 hours)
ASTM F 2170
REFER TO THE LATEST VERSION OF THE ASTM SPECIFICATIONS FOR SPECIFIC TESTING PROCEDURE.
pH TEST AND BOTH MOISTURE TESTS MUST BE PERFORMED AND RESULTS WITHIN SPECIFICATIONS BEFORE INSTALLATION.
IT IS THE FLOORING CONTRACTOR’S RESPONSIBILITY TO ENSURE THAT MOISTURE AND pH LEVELS IN THE CONCRETE COMPLY WITH SPECIFICATIONS.
FREQUENCY OF TESTS IS 3 TESTS FOR THE FIRST 1,000 SQ. FT. AND ONE TEST PER ADDITIONAL 1,000 SQ. FT.
FOR ACTIVE TEC, MOISTURE AND pH TESTS HAVE TO BE PERFORMED WHEN IN CONTACT WITH A CONCRETE BASED SUBFLOOR AND MEET INSTALLATION INSTRUCTIONS
SPECIFICATIONS.
REFER TO THE “FLOOR PREPARATION INSTRUCTIONS” AND “INSTALLATION INSTRUCTIONS” DOCUMENTS FOR SPECIFIC PREPARATION & INSTALLATION DETAILS.
MOHAWK GROUP WILL NOT BE HELD RESPONSIBLE FOR HYDROSTATIC PRESSURE THAT MAY OCCUR IN THE FUTURE.
IMPORTANT NOTICE: DO NOT USE CHEMICAL ADHESIVE REMOVAL PRODUCTS (CHEMICAL ABATEMENT PRODUCTS). THEIR USE WILL VOID MOHAWK GROUP’S ADHESIVE SYSTEM
WARRANTY UNLESS THE PROPER REMEDIATION SYSTEM IS USED PRIOR TO INSTALLATION.
TO TAKE CARE OF HIGH MOISTURE OR A CHEMICAL ABATEMENT SITUATION REFER TO THE REMEDIATION SYSTEMS DOCUMENT.
Mohawk Rubber Slate, Hammered, Infused, Natural Slate, and Round, Commercial Rubber Accessories, Medi-Flex, Medi-Flex TRUE, Stonewalk, Luxury Vinyl Tile, Ultimate Step are registered trademarks
of Mohawk Group.
Mohawk Group, 1975 West Oak Circle, Marietta GA, 30062
Phone: 800-554-6637
Customer Service 877-235-0453
Customer Service Fax 877-244-8054
Samples 888-740-6936
Installation / Maintenance 800-833-6954
Website : www.mohawkgroup.com
6016-M (2015-05-19)
Page 3 of 4
ADHESIVE QUICK CHECK CHART
Use of Adhesives and Remediation Membranes
American Biltrite’s position regarding the use of adhesives and remediation membranes for its flooring products is fairly simple. In order
to achieve the highest performance of our flooring products, extensive research was done on the performance of the products prior to
making these available to the market.
We also ran extensive tests, including pilot floor testing, climate change exposition and heavy rolling load to ensure that we minimize
any problematic situation that would result from our recommendations.
For these reasons, we will support our flooring products and the adhesives we have listed on our Quick Check Chart for the applications
they are intended for.
You can also refer to our document titled “Remediation Systems for All American Biltrite Flooring Products” found on our website.
All other adhesives and remediation membranes are the responsibility of the user.
We will not recognize any claim attributed to an adhesive failure if our recommendations are not followed either for the type of adhesive
or the intended application.