With cable gland: PCM5-C
With hole plug: PCM5
HM-5152-2
O P E R AT I N G MA N UA L
●
Housing of motor cover
Motor Cover
PCM5
PCM5-C
Attachments (supplied)
● Hexagonal socket
head screws
4 pieces
●
Housing of motor cover
Attachments (supplied)
● Hexagonal socket
head screws
4 pieces
Before use
The product described in this manual has been designed and manufactured to be
incorporated in general industrial equipment. Do not use for any other purpose.
Oriental Motor Co., Ltd. is not responsible for any damage caused through failure to
observe this warning.
Safety precautions
The precautions described below are intended to prevent danger or injury to the
user and other personnel through safe, correct use of the product. Use the product
only after carefully reading and fully understanding these instructions.
Handling the product without observing the instructions that
Warning accompany a "Warning" symbol may result in serious injury or death.
•• Do not use the product in explosive environments, in the presence of flammable
gases, or near combustibles. Doing so may result in fire or injury.
•• Do not use for any product other than applicable products. Doing so may result in
electric shock or damage to equipment.
•• When installing the motor, ground the Protective Earth Terminal of the motor.
Failure to do so may result in electric shock.
•• Install securely based on the installation condition or mounting instruction.
Failure to do so may result in electric shock or damage to equipment.
•• Do not forcibly bend or pull the cable. Doing so may result in electric shock or
damage to equipment.
●
Gasket
●
Gasket
This gasket is a consumable part.
An estimated timing for replacement is
approximately one year.
Hole plug
The gasket for replacement is provided as an
(cap and rubber washer) accessory (sold separately).
Supplied
B : Cable gland
E : Sealing nut
Pass the motor cable through B , and put the motor
cover over the motor.
Assembling the cable gland
1. Pass the cable through C and D .
Detach assembled
Mounting plate
Motor
C
and
Detach
D.
D
A
B
Slit
Install in the direction shown
in the figure.
Grounding
B
Grounding
Grounding wire∗
Grounding wire∗
■ When watertight and dust-resistant performance is not needed
The motor cover can be installed as shown in the figure below.
Remove the hole plug to pass through the cable.
Securely assemble C and D .
Incomplete assembling may cause
ingress of liquids.
∗ Connect the grounding wire to the grounding terminal of the driver
or equipment. When connecting, do not pinch the grounding wire
between the motor cover and the mounting plate.
or equipment. When connecting, do not pinch the grounding wire
between the motor cover and the mounting plate.
2
Assemble the cable gland.
Secure to the mounting plate with the supplied hexagonal
socket head screws.
Round shaft type
Motor
Install the motor cover to a flat metal plate.
Installation conditions
Reference panel cut-out
Center position for
mounting a motor
memo
Before covering the motor with the motor cover, consider the bending
of the cable as shown in the figure, and adjust the cable length to be
stored in the motor cover. Do not forcibly pull the cable.
Grounding
Note
If the once-tightened E is loosened, the assembling
state for B and the motor cover will also come loose.
Tighten B and the motor cover using the specified
torque in order to prevent ingress of liquids.
Cable
Mounting plate
memo
Tightening torque: 2.0 to 2.5 N·m
(17.7 to 22 lb-in)
Before covering the motor with the motor cover, consider the
bending of the cable as shown in the figure, and adjust the cable
length to be stored in the motor cover. Do not forcibly pull the cable.
Tightening torque: 2.0 to 2.5 N·m (17.7 to 22 lb-in)
B
E
Cover
[Unit: mm (in.)]
4×M5 or φ5.5 (φ0.217)∗1
71 (2.8) 57 (2.24)
136 (5.35)
102 (4.02)
Grounding
Pass the connector
(end) of the
connection cable
through D.
Cable
E
Tightening torque for when
attaching the hole plug again:
2.0 to 2.5 N·m (17.7 to 22 lb-in)
D
2. Pass the cable through E , and tighten to B .
Installation
Mounting plate
Install C to
the cable.
Round shaft type
Motor
•• Indoors • Operating ambient temperature: 0 to +40 °C (+32 to +104°F)
•• Operating ambient humidity 85% or less
•• Area that is free of explosive atmosphere or free of atmosphere which contains strong
acids, strong alkali or organic solvents (ethyl chloride, methyl chloride, cresol, etc.)
•• Area free of radioactive materials
• Area free of damp or ozonic atmosphere
•• Area not exposed to direct sun
•• Area not subject to continuous vibration or excessive shocks
•• Install the motor to a mounting plate of the following size or larger.
30 W and 60 W: 170 X 170 mm (6.69 X 6.69 in.) or larger
120 W: 250 X 250 mm (9.84 X 9.84 in.) or larger
Thickness: 5 mm (0.20 in.) Material: Aluminum alloy
C
Tightening torque: 1.49 to 2.5 N·m (13.1 to 22 ib-in)
Tightening torque: 1.49 to 2.5 N·m (13.1 to 22 ib-in)
••BMU Series: 30 W, 60 W, 120 W type
••BLE2 Series: 30 W, 60 W, 120 W type
Note
Cable
∗ Connect the grounding wire to the grounding terminal of the driver
Applicable product
C
Install to the cable as shown in
the right figure, and assemble
C with D .
Motor
Cable
C and D have
been assembled.
Applicable diameter of cable: φ6 to 10.5 mm
(φ0.24 to 0.41 in.)
Installation methods are explained using the connector type motor as
an example.
1
A : Rubber washer
D : Clamping claw
Installation method
Installation methods are explained using the connector type motor as
an example.
• Put on the motor cover after passing the motor cable through the hole
of the mounting plate.
• Secure to the mounting plate with the supplied hexagonal socket head
screws.
Mounting plate
Tightening torque: 1.49 to 2.5 N·m (13.1 to 22 ib-in)
1 piece
C : Sealing insert
Nuts
4 pieces
This gasket is a consumable part.
An estimated timing for replacement is approximately one year.
The gasket for replacement is provided as an accessory (sold separately).
Installation method
Precautions for use
•• The watertight performance of the motor cover is designed assuming fresh water
and tap water at normal temperature [+5 to +35 °C (+41 to +95 °F)]. Do not splash
hot water or blow hot air.
•• The motor cover cannot be used under water, and also cannot be washed by high
water pressure.
•• Tighten hexagonal socket head screws evenly so that the mounting surface of the
motor cover and the mounting plate are in parallel. Check periodically if any of
the tightened screws come loose. Re-tighten if the screw was loose.
Nuts
4 pieces
Cable gland
Assembled with
housing of
motor cover
Size: M5
Screw length 25 mm (0.98 in.)
(with washer)
Size: M5
Screw length 25 mm (0.98 in.)
(with washer)
Thank you for purchasing an Oriental Motor product.
Only qualified personnel of electrical and mechanical engineering should work with
the product.
Use the product correctly after thoroughly reading the section "Safety precautions."
●
φ20 (φ0.787)∗2
∗1
Machining of mounting hole
M5: To secure with screws only
φ5.5 (φ0.217): To secure with screws
and nuts
∗2
φ20 (φ0.787) is a hole size for when
passing a cable and a grounding wire
through the mounting plate.
Specifications of motor cover
•• Degree of protection: IP66 (classification stated in IEC 60529)
•• Material:
Polycarbonate
(flammability grade UL94V-0)
Hexagonal socket head screw, nut Stainless steel
Gasket
Nitrile butadiene rubber
Cable gland
Nylon 66 (flammability grade UL94V-2),
ethylene propylene diene rubber
Hole plug
Housing of motor cover
•• RoHS Directive:The products do not contain the substances exceeding the
restriction values of RoHS Directive (2011/65/EU).
•• Oriental Motor shall not be liable whatsoever for any problems relating to industrial property rights arising from use of any information, circuit, equipment or device provided
or referenced in this manual.
•• Characteristics, specifications and dimensions are subject to change without notice.
••
is a registered trademark or trademark of Oriental Motor Co., Ltd., in Japan and other countries.
© Copyright ORIENTAL MOTOR CO., LTD. 2017
Published in July 2017
• Please contact your nearest Oriental Motor office for further information.
Technical Support Tel:(800)468-3982
8:30 A.M. to 5:00 P.M., P.S.T. (M-F)
7:30 A.M. to 5:00 P.M., C.S.T. (M-F)
www.orientalmotor.com
Tel:+55-11-3266-6018
www.orientalmotor.com.br
Schiessstraße 44, 40549 Düsseldorf, Germany
Technical Support Tel:00 800/22 55 66 22
www.orientalmotor.de
Tel:01256-347090
www.oriental-motor.co.uk
Tel:01 47 86 97 50
www.orientalmotor.fr
Tel:02-93906346
www.orientalmotor.it
4-8-1Higashiueno,Taito-ku,Tokyo 110-8536
Japan
Tel:03-6744-0361
www.orientalmotor.co.jp
Singapore Tel:1800-8420280
www.orientalmotor.com.sg
Tel:1800-806161
www.orientalmotor.com.my
Tel:1800-888-881
www.orientalmotor.co.th
Korea Tel:080-777-2042
www.inaom.co.kr
Tel:+91-80-41125586
www.orientalmotor.co.in
Hong Kong Branch
Tel:+852-2427-9800
Tel:0800-060708
www.orientalmotor.com.tw
Tel:400-820-6516
www.orientalmotor.com.cn