Product Data Sheet: Rosemount 3051S Series of

Product Data Sheet: Rosemount 3051S Series of
Product Data Sheet
October 2017
00813-0100-4801, Rev UG
Rosemount™ 3051S Series of Instrumentation
Scalable pressure, flow, and level solutions
Innovation reaching across your operation
With the Rosemount 3051S Series of Instrumentation, operations can be optimized in these critical areas:
production, quality, energy efficiency, and safety and environment. By leveraging the power of the scalable
Rosemount 3051S across the entire operation, you’ll be able to minimize process variability, gain greater process
insight, reduce maintenance and downtime, and meet regulatory demands. What’s more, it’s easy to use,
ensuring the full potential of the measurement investment is realized.
Rosemount 3051S Series
October 2017
Rosemount 3051S SuperModule™ Platform
The most advanced pressure, flow, and level measurements

The all-welded hermetic SST design delivers the industry's highest field reliability.

Ultra performance provides up to ±0.025% accuracy and 200:1 rangedown.

Ultra for Flow performance provides up to ±0.04% of reading and 14:1 flow turndown.

15-year stability and 15-year limited warranty

SIL3 Capable: IEC 61508 certified by an accredited 3rd party agency for use in safety
instrumented systems up to SIL 3 (minimum requirement of single use [1oo1] for SIL 2 and
redundant use [1oo2] for SIL 3).

IEC 61508 Functional Safety Specifications for 3051S are detailed at
Emerson.com/Rosemount/Safety.
Rosemount 3051S Series selection guide
Rosemount 3051S Coplanar™ differential, gage, or absolute transmitter
See ordering information on page 5.

Coplanar platform enables integrated manifold, primary element, and seal system solutions.

Dual-capacitance Saturn™ sensor technology corrects for overpressure and line pressure
effects.

Calibrated spans from 0.1 inH2O to 4000 psi (0,25 mbar to 276 bar).

Available with 316L SST, Alloy C-276, Alloy 400, Tantalum, gold-plated Alloy 400, or
gold-plated 316L SST process isolators
Rosemount 3051S In-line gage or absolute transmitter
See ordering information on page 15.

Direct threaded connection, manifold or seal system solutions

Piezoresistive sensor technology allows calibrated spans from 0.3 to 10000 psi (20,7 mbar to
689 bar).

Available with 316L SST or Alloy C-276 process isolators
Contents
Rosemount 3051S Coplanar Pressure Transmitter . . . . . 5
Rosemount 3051S Scalable Level Transmitter . . . . . . . .73
Rosemount 3051S In-line Pressure Transmitter . . . . . . 15
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104
Rosemount 3051S MultiVariable Transmitter . . . . . . . . 22
Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . .129
Rosemount 3051SF DP Flowmeters . . . . . . . . . . . . . . . . 31
Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . .145
Rosemount 3051S Electronic Remote Sensor (ERS)
System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160
2
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Rosemount 3051S MultiVariable™ Transmitter
See ordering information on page 22.

Combines differential pressure, static pressure, and process temperature measurements along
with mass and energy flow in a single device.

Compensates for 25+ different variables providing accurate and repeatable flow readings.

Customize pressure and temperature compensation for any flow application.

Easily configure flow and device parameters with Engineering Assistant Software.
Rosemount 3051SF DP Flowmeters
See ordering information on page 31.

Integrates the Rosemount 3051S with Rosemount’s industry leading primary elements to
create one complete flowmeter assembly.

Fully assembled, configured and leak tested for out-of-the-box installation.

Reduce installed costs by replacing ten parts traditionally used for a DP Flow installation with
one flowmeter.

Reduce straight pipe requirements, lower permanent pressure loss, and achieve accurate
measurement in small line sizes.
Rosemount 3051S Electronic Remote Sensor (ERS™) System
See ordering information on page 59.

The industry’s first digital DP Level architecture consists of a single 4–20 mA HART® loop with
two Rosemount 3051S pressure sensors connected electronically.

Unique digital architecture enables stable and repeatable DP Level measurements on tall
vessels, towers, and applications with wide-varying temperatures.

Achieve increased process insight and diagnostics with multivariable measurements including
DP, pressure, and scaled variable for tank level or volume.

Simplify installations and maintenance by eliminating wet or dry legs, heat tracing, and purge
systems.
Rosemount 3051S Level Transmitter
See ordering information on page 73.

Level transmitters combine world-class Rosemount 3051S Pressure Transmitters with direct
mount seals, all in a single integrated model number.

Connect to virtually any process with a comprehensive offering of seal types, sizes, fill fluids,
and diaphragm materials.

Combine with an Rosemount 1199 Remote Mount Seal to form a Tuned-System™ Assembly for
a cost effective, easy-to-install DP Level measurement solution.
Emerson.com/Rosemount
3
Rosemount 3051S Series
October 2017
Advanced functionality
WirelessHART® (IEC 62591) capabilities
Available on coplanar, in-line, multivariable, DP flowmeters and level transmitters

Quickly deploy new pressure, level and flow measurements in 70 percent less time.

Eliminate wiring design and construction complexities to lower costs by 40–60 percent.

Reduce pipe penetrations and impulse piping with industry-leading multivariable technology.

Extended range antenna capabilities provide access to remote locations.

Delivering over a decade of maintenance free performance with 15-year stability and 10-year
power module life.
Advanced diagnostic capabilities
Available on coplanar, in-line, DP flowmeters and level transmitters

Provides diagnostic coverage from the process to the transmitter to the host.

Prevent on-scale failures by diagnosing electrical loop issues with power advisory diagnostics.

Statistical Process Monitoring (SPM) detects abnormal process conditions enabling more
productive and safer operations.

Extend diagnostic coverage to Safety Instrumented Systems with IEC 61508 SIL 2/3 capable
rating.
Remote display and interface
Available on coplanar, in-line, DP flowmeters, electronic remote sensors, and level
transmitters

Direct mount to the process and access transmitter capabilities and diagnostics at grade.

Get access up to 100 ft. (30 m) away from the process to ensure personnel safety.

Eliminate the need for impulse lines for best practice installations.
Rosemount instrument manifolds
Available on traditional, coplanar, and in-line transmitters

Designed and engineered to provide optimal performance with Rosemount 3051S Transmitters.

Reduce cost and leak points with flangeless coplanar design.

Fully integrated manifold and transmitter assemblies come fully leak checked, calibrated and
assembled allowing for one purchase order to save time and cost.

Rosemount manifolds provide a wide variety of styles, materials, and configurations to fit any
process.
4
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Rosemount 3051S Coplanar Pressure Transmitter
Rosemount 3051S Coplanar Pressure Transmitters are the industry leader for differential,
gage, and absolute pressure measurement. The coplanar platform allows seamless
integration with manifolds, primary elements, and seal solutions. Capabilities include:

Ultra, ultra for flow, and classic performance

4–20 mA HART, Wireless, FOUNDATION™ Fieldbus protocols

Safety Certification (Option code QT)

Advanced Diagnostics (Option code DA2)

Remote Display and Interface (Option code M7, M8, or M9)
Additional Information
Rosemount 3051S Coplanar
Pressure Transmitter
Specifications: page 104
Certifications: page 129
Dimensional drawings: page 145
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 124 for more information on material selection.
Table 1. Rosemount 3051S Scalable™ Coplanar Pressure Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Model
Transmitter type
3051S
Scalable pressure transmitter
Performance class(1)
1
Ultra: 0.025% span accuracy, 200:1 rangedown, 15-yr stability, 15-yr limited warranty
★
3(2)
Ultra for Flow: 0.04% reading accuracy, 200:1 turndown, 15-yr stability, 15-yr limited warranty
★
2
Classic: 0.035% span accuracy, 150:1 rangedown, 15-yr stability
★
Connection type
C
★
Coplanar
Measurement type(3)
D
Differential
★
G
Gage
★
A
Absolute
Pressure range
Differential
Gage
Absolute
1A
–25 to 25 inH2O
(–62,16 to 62,16 mbar)
–25 to 25 inH2O
(–62,16 to 62,16 mbar)
0 to 30 psia
(0 to 2,07 bar)
★
2A
–250 to 250 inH2O
(–621,60 to 621,60 mbar)
–250 to 250 inH2O
(–621,60 to 621,60 mbar)
0 to 150 psia
(0 to 10,34 bar)
★
3A
–1000 to 1000 inH2O
(–2,49 to 2,49 bar)
–393 to 1000 inH2O
(–0,97 to 2,49 bar)
0 to 800 psia
(0 to 55,16 bar)
★
Emerson.com/Rosemount
5
Rosemount 3051S Series
October 2017
Table 1. Rosemount 3051S Scalable™ Coplanar Pressure Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
4A
–300 to 300 psi
(–20,68 to 20,68 bar)
–14.2 to 300 psig
(–0,97 to 20,68 bar)
0 to 4000 psia
(0 to 275,79 bar)
★
5A
–2000 to 2000 psi
(–137,89 to 137,89 bar)
–14.2 to 2000 psig
(–0,97 to 137,89 bar)
N/A
★
0A(4)
–3 to 3 inH2O
(–7,46 to 7,46 mbar)
N/A
0 to 5 psia
(0 to 0,34 bar)
Isolating diaphragm
2(5)
316L SST
★
3(5)
Alloy C-276
★
4(5)
Alloy 400
5(6)
Tantalum
6(5)
Gold-plated Alloy 400 (includes graphite-filled PTFE O-ring)
7(5)
Gold-plated 316L SST
Materials of construction
Process connection
Size
Flange material
Drain vent
Bolting
000
None (no process flange)
N/A
N/A
N/A
N/A
★
A11(7)
Assemble to Rosemount 305
integral manifold
N/A
N/A
N/A
N/A
★
A12(7)
Assemble to Rosemount 304 or
AMF manifold and SST
traditional flange
N/A
N/A
N/A
N/A
★
A15
Assemble to Rosemount 304 or
AMF manifold to SST traditional
flange with Alloy C-276 drain
vents
N/A
N/A
N/A
N/A
★
A16(7)
Assemble to 304 or AMF
manifold to DIN SST traditional
flange
N/A
N/A
N/A
N/A
★
A22
Assemble AMF manifold to SST
coplanar flange
N/A
N/A
N/A
N/A
★
B11(7)(8)(9)
Assemble to one Rosemount
1199 seal
N/A
SST
N/A
N/A
★
B12(7)(8)(9)
Assemble to two Rosemount
1199 seals
N/A
SST
N/A
N/A
★
C11(7)
Assemble to Rosemount 405C
or 405P primary element
N/A
N/A
N/A
N/A
★
D11(7)
Assemble to Rosemount 1195
integral orifice and Rosemount
305 integral manifold
N/A
N/A
N/A
N/A
★
EA2(7)
Assemble to Rosemount 485 or
405A Annubar™ primary
element with coplanar flange
N/A
SST
316 SST
N/A
★
6
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 1. Rosemount 3051S Scalable™ Coplanar Pressure Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
EA3(7)
Assemble to Rosemount 485 or
405A Annubar primary element
with coplanar flange
N/A
Cast C-276
Alloy C-276
N/A
★
EA5(7)
Assemble to Rosemount 485 or
405A Annubar primary element
with coplanar flange
N/A
SST
Alloy C-276
N/A
★
E11
Coplanar flange
1 4
/ –18 NPT
CS
316 SST
N/A
★
E12
Coplanar flange
1 4
/ –18 NPT
SST
316 SST
N/A
★
E13(5)
Coplanar flange
1 4
/ –18 NPT
Cast C-276
Alloy C-276
N/A
★
E14
Coplanar flange
1 4
/ –18 NPT
Cast Alloy 400
Alloy 400/K-500
N/A
★
E15(5)
Coplanar flange
1 4
/ –18 NPT
SST
Alloy C-276
N/A
★
E16(5)
Coplanar flange
1 4
/ –18 NPT
CS
Alloy C-276
N/A
★
E21
Coplanar flange
RC 1/4
CS
316 SST
N/A
★
E22
Coplanar flange
RC 1/4
SST
316 SST
N/A
★
E23(5)
Coplanar flange
RC /
Cast C-276
Alloy C-276
N/A
★
E24
Coplanar flange
RC 1/4
Cast Alloy 400
Alloy 400/K-500
N/A
★
E25(5)
Coplanar flange
RC 1/4
SST
Alloy C-276
N/A
★
E26(5)
Coplanar flange
RC /
CS
Alloy C-276
N/A
★
F12
Traditional flange
1 4
/ –18 NPT
SST
316 SST
N/A
★
F13(5)
Traditional flange
1 4
/ –18 NPT
Cast C-276
Alloy C-276
N/A
★
F14
Traditional flange
1 4
/ –18 NPT
Cast Alloy 400
Alloy 400/K-500
N/A
★
F15(5)
Traditional flange
1 4
/ –18 NPT
SST
Alloy C-276
N/A
★
F22
Traditional flange
RC 1/4
SST
316 SST
N/A
★
F23(5)
Traditional flange
RC 1/4
Cast C-276
Alloy C-276
N/A
★
F24
Traditional flange
RC 1/4
Cast Alloy 400
Alloy 400/K-500
N/A
★
F25(5)
Traditional flange
RC /
SST
Alloy C-276
N/A
★
F52
DIN-compliant traditional flange
/ –18 NPT
SST
316 SST
/ -in. bolting
★
G11
Vertical mount level flange
2-in. ANSI class 150
SST
316 SST
N/A
★
G12
Vertical mount level flange
2-in. ANSI class 300
SST
316 SST
N/A
★
G21
Vertical mount level flange
3-in. ANSI class 150
SST
316 SST
N/A
★
G22
Vertical mount level flange
3-in. ANSI class 300
SST
316 SST
N/A
★
G31
Vertical mount level flange
DIN- DN 50 PN 40
SST
316 SST
N/A
★
G41
Vertical mount level flange
DIN- DN 80 PN 40
SST
316 SST
N/A
★
F32
Bottom vent traditional flange
/ –18 NPT
SST
316 SST
N/A
F42
Bottom vent traditional flange
RC 1/4
SST
316 SST
N/A
F62
DIN-compliant traditional flange
1 4
/ –18 NPT
SST
316 SST
M10 bolting
F72
DIN-compliant traditional flange
1 4
/ –18 NPT
SST
316 SST
M12 bolting
Emerson.com/Rosemount
1 4
1 4
1 4
1 4
1 4
7 16
7
Rosemount 3051S Series
October 2017
Table 1. Rosemount 3051S Scalable™ Coplanar Pressure Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Transmitter output
A
4–20 mA with digital signal based on HART protocol
★
F(10)
FOUNDATION Fieldbus protocol
★
X(11)
Wireless (requires wireless options and wireless Plantweb™ housing)
★
Housing style
Material
Conduit entry
size
N/A
N/A
★
00
None (SuperModule spare part, order output code A)
1A
Plantweb housing
Aluminum
1 2
/ –14 NPT
★
1B
Plantweb housing
Aluminum
M20 ⫻1.5
★
1J
Plantweb housing
SST
1 2
/ –14 NPT
★
1K
Plantweb housing
SST
M20 ⫻ 1.5
★
5A(12)
Wireless Plantweb housing
Aluminum
1 2
/ –14 NPT
★
5J(12)
Wireless Plantweb housing
SST
1 2
/ –14 NPT
★
2A
Junction Box housing
Aluminum
1 2
/ –14 NPT
★
2B
Junction Box housing
Aluminum
M20 ⫻ 1.5
★
2J
Junction Box housing
SST
1 2
/ –14 NPT
★
2E
Junction Box housing with output for remote display and interface
Aluminum
1 2
/ –14 NPT
★
2F
Junction Box housing with output for remote display and interface
Aluminum
M20 ⫻ 1.5
★
2M
Junction Box housing with output for remote display and interface
SST
/ –14 NPT
★
7J(13)
Quick Connect (A size mini, 4-pin male termination)
SST
N/A
★
1 2
1C
Plantweb housing
Aluminum
G/
1L
Plantweb housing
SST
G1/2
2C
Junction Box housing
Aluminum
G1/2
2G
Junction Box housing with output for remote display and interface
Aluminum
G1/2
1 2
Wireless options (requires option code X and wireless Plantweb housing)
Update rate
WA
User configurable update rate
★
Operating frequency and protocol
3
2.4 GHz DSSS, IEC 62591 (WirelessHART)
★
Omni-directional wireless antenna
WK
External antenna
★
WM
Extended range, external antenna
★
WJ
Remote antenna
WN
High-gain, remote antenna
8
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 1. Rosemount 3051S Scalable™ Coplanar Pressure Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
SmartPower™ (14)
1
Adapter for black power module (I.S. Power Module sold separately)
★
Other options (include with selected model number)
HART Revision configuration (requires HART Protocol output code A)(15)
HR7
Configured for HART Revision 7
★
Extended product warranty
WR3
3-year limited warranty
★
WR5
5-year limited warranty
★
Plantweb control functionality
A01
FOUNDATION Fieldbus advanced control function block suite
★
Plantweb diagnostic functionality
D01
FOUNDATION Fieldbus diagnostics suite
★
DA2(16)
Advanced HART diagnostics suite
★
Plantweb enhanced measurement functionality(17)
H01
FOUNDATION Fieldbus fully compensated mass flow block
★
Mounting bracket(18)
B4
Coplanar flange bracket, all SST, 2-in. pipe and panel
★
B1
Traditional flange bracket, CS, 2-in. pipe
★
B2
Traditional flange bracket, CS, panel
★
B3
Traditional flange flat bracket, CS, 2-in. pipe
★
B7
Traditional flange bracket, B1 with SST bolts
★
B8
Traditional flange bracket, B2 with SST bolts
★
B9
Traditional flange bracket, B3 with SST bolts
★
BA
Traditional flange bracket, B1, all SST
★
BC
Traditional flange bracket, B3, all SST
★
Software configuration
C1(19)
Custom software configuration (requires Configuration Data Sheet)
★
C2
Custom flow configuration (requires H01 and Configuration Data Sheet)
★
Gage pressure calibration
C3
Gage pressure calibration on Rosemount 3051S_CA4 only
★
Alarm limit(19)(20)
C4
NAMUR alarm and saturation levels, high alarm
★
C5
NAMUR alarm and saturation levels, low alarm
★
Emerson.com/Rosemount
9
Rosemount 3051S Series
October 2017
Table 1. Rosemount 3051S Scalable™ Coplanar Pressure Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
C6
Custom alarm and saturation signal levels, high alarm (requires C1 and Configuration Data Sheet)
★
C7
Custom alarm and saturation signal levels, low alarm (requires C1 and Configuration Data Sheet)
★
C8
Low alarm (standard Rosemount alarm and saturation levels)
★
Hardware adjustments(19)(20)(21)
D1
Hardware adjustments (zero, span, alarm, security)
★
Flange adapter(22)
/ -14 NPT flange adapter
D2
1 2
D9
RC1/2 SST flange adapter
★
Custody transfer(23)
D3
Measurement Canada accuracy approval
★
Ground screw(24)
D4
External ground screw assembly
★
Drain/vent valve(22)
D5
Delete transmitter drain/vent valves (install plugs)
D7
SST coplanar flange without drain/vent ports
★
Conduit plug(25)
DO
316 SST conduit plug
★
Product certifications(26)
E1
ATEX Flameproof
★
I1
ATEX Intrinsic Safety
★
IA
ATEX FISCO Intrinsic Safety (FOUNDATION fieldbus protocol only)
★
N1
ATEX Type n
★
K1
ATEX Flameproof, Intrinsic Safety, Type n, Dust
★
ND
ATEX Dust
★
E4
TIIS Flameproof
★
I4(12)
TIIS Intrinsic Safety
★
E5
FM Explosion-proof, Dust Ignition-proof
★
I5
FM Intrinsically Safe; Nonincendive
★
IE
FM FISCO Intrinsically Safe (FOUNDATION Fieldbus protocol only)
★
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
E6(27)
CSA Explosion-proof, Dust Ignition-proof, Division 2
★
I6
CSA Intrinsically Safe
★
IF
CSA FISCO Intrinsically Safe (FOUNDATION Fieldbus protocol only)
★
K6(27)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
10
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 1. Rosemount 3051S Scalable™ Coplanar Pressure Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
E7
IECEx Flameproof, Dust
★
I7
IECEx Intrinsic Safety
★
IG
IECEx FISCO Intrinsic Safety (FOUNDATION Fieldbus protocol only)
★
N7
IECEx Type n
★
K7
IECEx Flameproof, Dust, Intrinsic Safety, Type n
★
E2
INMETRO Flameproof
★
I2
INMETRO Intrinsic Safety
★
IB
INMETRO FISCO Intrinsic Safety
★
K2
INMETRO Flameproof, Intrinsic Safety
★
E3
China Flameproof
★
I3
China Intrinsic Safety
★
N3
China Type n
★
EP
Korea Flameproof
★
IP
Korea Intrinsic Safety
★
KP
Korea Flameproof, Intrinsic Safety
★
EM
Technical Regulations Customs Union (EAC) Flameproof
★
IM
Technical Regulations Customs Union (EAC) Intrinsic Safety
★
KM
Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety
★
KA(27)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2
★
KB(27)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2
★
KD(27)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe
★
KG
FM, CSA, ATEX and IECEx FISCO Intrinsic Safety
★
Shipboard approvals
SBS
American Bureau of Shipping
★
SBV
Bureau Veritas (BV) Type Approval
★
SDN
Det Norske Veritas (DNV) Type Approval
★
SLL
Lloyds Register (LR) Type Approval
★
Sensor fill fluid(28)
L1
Inert sensor fill fluid
★
Graphite-filled PTFE O-ring
★
O-ring
L2
Bolting material(22)
L4
Austenitic 316 SST bolts
★
L5
ASTM A 193, Grade B7M bolts
★
Emerson.com/Rosemount
11
Rosemount 3051S Series
October 2017
Table 1. Rosemount 3051S Scalable™ Coplanar Pressure Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
L6
Alloy K-500 bolts
★
L7(29)
ASTM A453, Class D, Grade 660 bolts
★
L8
ASTM A193, Class 2, Grade B8M bolts
★
Display type(30)
M5
Plantweb LCD display
★
M7(20)(31)(32)
Remote mount LCD display and interface, Plantweb housing, no cable, SST bracket
★
M8(20)(31)
Remote mount LCD display and interface, Plantweb housing, 50 ft. (15 m) cable, SST bracket
★
M9(20)(31)
Remote mount LCD display and interface, Plantweb housing, 100 ft. (31 m) cable, SST bracket
★
Pressure testing(33)
P1
Hydrostatic testing with certificate
Special cleaning(22)
P2
Cleaning for special services
P3
Cleaning for special services with testing for <1PPM chlorine/fluorine
Maximum static line pressure
P9(34)
4500 psig (310 bar) static pressure limit (Rosemount 3051S_CD only)
★
P0(35)
6092 psig (420 bar) static pressure limit (Rosemount 3051S2CD only)
★
Calibration certification
Q4
Calibration certificate
★
QP
Calibration certificate and tamper evident seal
★
Material traceability certification
Q8
Material traceability certification per EN 10204 3.1
★
Quality certification for safety(36)
QS
Prior-use certificate of FMEDA data
★
QT
Safety-certified to IEC 61508 with certificate of FMEDA data
★
Transient protection(37)(38)
T1
Transient terminal block
★
Drinking water approval(39)
DW
NSF drinking water approval
★
Surface finish certification
Q16
Surface finish certification for sanitary remote seals
★
Toolkit total system performance reports
QZ
12
Remote seal system performance calculation report
★
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 1. Rosemount 3051S Scalable™ Coplanar Pressure Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Conduit electrical connector(40)
GE
M12, 4-pin, male connector (eurofast®)
★
GM
A size mini, 4-pin, male connector (minifast®)
★
NACE® certificate(41)
Q15
Certificate of compliance to NACE MR0175/ISO 15156 for wetted materials
★
Q25
Certificate of compliance to NACE MR0103 for wetted materials
★
Typical model number:
3051S1CD 2A 2 E12 A 1A DA2 B4 M5
1.
For detailed specifications see “Specifications” on page 104.
2.
This option is only available with range codes 2A and 3A, 316L SST or Alloy C-276 isolating diaphragm and silicone fill fluid.
3.
Performance Class code 3 is available with Measurement Type code D only.
4.
3051S_CD0 is only available with SST traditional flange, 316L SST diaphragm material, and Bolting option L4.
5.
Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
Order with Q15 or Q25 to receive a NACE certificate.
6.
Tantalum diaphragm material is only available for ranges 2A–5A, differential and gage.
7.
“Assemble to” items are specified separately and require a completed model number. Process connection option codes B12, C11, D11, EA2, EA3, and EA5 are only
available on differential Measurement Type, code D.
8.
Consult an Emerson™ Process Management representative for performance specifications.
9.
Not available with Performance Class code 3.
10.
Requires Plantweb housing.
11.
Only intrinsically safe approval codes apply.
12.
Only available with output code X.
13.
Available with output code A only. Available approvals are FM Intrinsically Safe; Nonincendive (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic
Safety (option code I1), or IECEx Intrinsic Safety (option code I7). Contact an Emerson representative for additional information.
14.
Long-Life Power Module must be shipped separately, order Power Module 701PBKKF.
15.
Option HR7 configures the HART output to HART Revision 7. This option requires the selection of the Advanced Diagnostics (DA2) option. The device with this option
can be field configured to HART Revision 5 or 7 if desired.
16.
Requires Plantweb housing and output code A. Includes Hardware Adjustments as standard.
17.
Requires Rosemount Engineering Assistant to configure.
18.
For process connection option code A11, the mounting bracket must be ordered as part of the manifold model number.
19.
Not available with output code F.
20.
Not available with output code X.
21.
Not available with housing style codes 00, 2E, 2F, 2G, 2M, 5A, 5J, or 7J.
22.
Not available with process connection option code A11.
23.
Requires Plantweb housing and Hardware Adjustments option code D1. Limited availability depending on transmitter type and range. Contact an Emerson
representative for additional information.
24.
This assembly is included with options EP, KP, E1, N1, K1, ND, E4, E7, N7, K7, E2, E3, KA, KC, KD, IA, IB, IE, IF, IG, KG, T1, K2, N3, EM, and KM.
25.
Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
26.
Valid when SuperModule Platform and housing have equivalent approvals.
27.
Not available with M20 or G 1/2 conduit entry size.
28.
Only available on differential and gage measurement types. Silicone fill fluid is standard.
29.
Bolts are not considered process wetted. In instances where NACE MR0175/ISO 15156 and NACE MR0103 conformance is required for bolting, L7 is the
recommended bolting option.
30.
Not available with Housing code 7J.
31.
Not available with output code F, option code DA2, or option code QT.
32.
See the Rosemount 3051S Reference Manual for cable requirements. Contact an Emerson representative for additional information.
33.
P1 is not available with 3051S_CA0.
Emerson.com/Rosemount
13
Rosemount 3051S Series
October 2017
34.
When assembled to remote diaphragm seal system using B11 or B12process connections, the maximum working pressure of the system may be limited by the rating
of the Rosemount 1199 Seal System selected.
35.
Requires 316L SST, Alloy C-276, or Gold-plated 316L SST diaphragm material, assemble to Rosemount 305 integral manifold or DIN-compliant traditional flange
process connection, and bolting option L8. Limited to Pressure Range (Differential), ranges 2A – 5A.
36.
Not available with output code F or X. Not available with housing code 7J.
37.
Not available with Housing code 00, 5A, 5J, or 7J.
38.
The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IB, IE, IF, IG, and KG.
39.
Requires 316L SST diaphragm material, glass-filled PTFE O-ring (standard), and Process Connection code E12 or F12.
40.
Not available with Housing code 00, 5A, 5J, or 7J. Available with Intrinsically Safe approvals only. For FM Intrinsically Safe; Nonincendive (option code I5) or FM FISCO
Intrinsically Safe (option code IE), install in accordance with Rosemount drawing 03151-1009. Suitable for use with all IS approvals (I1, I2, I3, I5, I6, I7, IA, IB, IE, IF,
IG, IP, IM, KG).
41.
NACE compliant wetted materials are identified by Footnote 5.
14
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Rosemount 3051S In-line Pressure Transmitter
Rosemount 3051S In-line Pressure Transmitters are the industry leader for Gage and
Absolute pressure measurement. The in-line, compact design allows the transmitter to
be connected directly to a process for quick, easy and cost effective installation.
Capabilities include:

Ultra and Classic Performance

4–20 mA HART, Wireless, FOUNDATION Fieldbus protocols

Safety Certification (Option code QT)

Advanced Diagnostics (Option code DA2)

Remote Display and Interface (Option code M7, M8, or M9)
Additional information
Rosemount 3051S In-line
Pressure Transmitter
Specifications: page 104
Certifications: page 129
Dimensional Drawings: page 145
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 124 for more information on material selection.
Table 2. Rosemount 3051S Scalable In-line Pressure Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Model
Transmitter type
3051S
Scalable pressure transmitter
Performance class(1)
1
Ultra: 0.025% span accuracy, 200:1 rangedown, 15-yr stability, 15-yr limited warranty
★
2
Classic: 0.035% span accuracy, 150:1 rangedown, 15-yr stability
★
Connection type
T
★
In-line
Measurement type
G
Gage
★
A
Absolute
★
Pressure range
Gage
Absolute
1A
–14.7 to 30 psi (–1,01 to 2,06 bar)
0 to 30 psia (2,06 bar)
★
2A
–14.7 to 150 psi (–1,01 to 10,34 bar)
0 to 150 psia (10,34 bar)
★
3A
–14.7 to 800 psi (–1,01 to 55,15 bar)
0 to 800 psia (55,15 bar)
★
4A
–14.7 to 4000 psi (–1,01 to 275,79 bar)
0 to 4000 psia (275,79 bar)
★
5A
–14.7 to 10000 psi (–1,01 to 689,47 bar)
0 to 10000 psia (689,47 bar)
★
Isolating diaphragm(2)(3)
2
316L SST
★
3
Alloy C-276
★
Emerson.com/Rosemount
15
Rosemount 3051S Series
October 2017
Table 2. Rosemount 3051S Scalable In-line Pressure Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Process connection
A11(4)
Assemble to Rosemount 306 integral manifold
★
B11(4)(5)
Assemble to one Rosemount 1199 seal
★
E11
1 2
★
G11
G1/2 A DIN 16288 male (range 1–4 only)
★
H11
Coned and threaded, compatible with autoclave type F-250-C (range 5A only)
F11
Non-threaded instrument flange (I-flange) (range 1–4 only)
/ –14 NPT female
Transmitter output
A
4–20 mA with digital signal based on HART protocol
★
F(6)
FOUNDATION Fieldbus protocol
★
X(7)
Wireless (requires wireless options and wireless Plantweb housing)
★
Housing style
Material
Conduit entry size
N/A
★
Aluminum
1 2
/ –14 NPT
★
Plantweb housing
Aluminum
M20 ⫻ 1.5
★
1J
Plantweb housing
SST
1 2
/ –14 NPT
★
1K
Plantweb housing
SST
M20 ⫻ 1.5
★
5A(8)
Wireless Plantweb housing
Aluminum
1 2
/ –14 NPT
★
5J(8)
Wireless Plantweb housing
SST
1 2
/ –14 NPT
★
2A
Junction box housing
Aluminum
1 2
/ –14 NPT
★
2B
Junction box housing
Aluminum
M20 ⫻ 1.5
★
2J
Junction box housing
SST
1 2
/ –14 NPT
★
2E
Junction box housing with output for remote display and interface
Aluminum
1 2
/ –14 NPT
★
2F
Junction box housing with output for remote display and interface
Aluminum
M20 ⫻ 1.5
★
2M
Junction box housing with output for remote display and interface
SST
/ –14 NPT
★
7J(9)
Quick Connect (A size mini, 4-pin male termination)
SST
N/A
★
1C
Plantweb housing
Aluminum
G1/2
1L
Plantweb housing
SST
G1/2
2C
Junction Box housing
Aluminum
G1/2
2G
Junction Box housing with output for remote display and interface
Aluminum
G1/2
00
None (SuperModule spare part, order output code A)
1A
Plantweb housing
1B
N/A
1 2
Wireless options (requires option code X and wireless Plantweb housing)
Update rate
WA
16
User configurable update rate
★
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 2. Rosemount 3051S Scalable In-line Pressure Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Operating frequency and protocol
3
2.4 GHz DSSS, IEC 62591 (WirelessHART)
★
Omni-directional wireless antenna
WJ
Remote antenna
WK
External antenna
★
WM
Extended range, external antenna
★
WN
High-Gain, remote antenna
SmartPower(10)
1
Adapter for Black Power Module (I.S. Power Module sold separately)
★
Other options (Include with selected model number)
HART Revision configuration (requires HART Protocol output code A)(11)
HR7
Configured for HART Revision 7
★
Extended product warranty
WR3
3-year limited warranty
★
WR5
5-year limited warranty
★
Plantweb control functionality
A01
FOUNDATION Fieldbus advanced control function block suite
★
Plantweb diagnostic functionality
D01
FOUNDATION Fieldbus diagnostics suite
★
DA2(12)
Advanced HART diagnostics suite
★
Mounting bracket
B4
Bracket, all SST, 2-in. pipe and panel
★
Software configuration(13)
C1
Custom software configuration (requires Configuration Data Sheet)
★
Alarm limit(13)(14)
C4
NAMUR alarm and saturation levels, high alarm
★
C5
NAMUR alarm and saturation levels, low alarm
★
C6
Custom alarm and saturation signal levels, high alarm (requires C1 and Configuration Data Sheet)
★
C7
Custom alarm and saturation signal levels, low alarm (requires C1 and Configuration Data Sheet)
★
C8
Low alarm (standard Rosemount alarm and saturation levels)
★
Hardware adjustments(13)(14)(15)
D1
Hardware adjustments (zero, span, alarm, security)
Emerson.com/Rosemount
★
17
Rosemount 3051S Series
October 2017
Table 2. Rosemount 3051S Scalable In-line Pressure Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Custody transfer(16)
D3
Measurement Canada accuracy approval
★
Ground screw(17)
D4
External ground screw assembly
★
Conduit plug(18)
DO
316 SST conduit plug
★
Product certifications(19)
E1
ATEX Flameproof
★
I1
ATEX Intrinsic Safety
★
IA
ATEX FISCO Intrinsic Safety (FOUNDATION Fieldbus protocol only)
★
N1
ATEX Type n
★
K1
ATEX Flameproof, Intrinsic Safety, Type n, Dust
★
ND
ATEX Dust
★
E4
TIIS Flameproof
★
I4(8)
TIIS Intrinsic Safety
★
E5
FM Explosion-proof, Dust Ignition-proof
★
I5
FM Intrinsically Safe; Nonincendive
★
IE
FM FISCO Intrinsically Safe (FOUNDATION Fieldbus protocol only)
★
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
E6(20)
CSA Explosion-proof, Dust Ignition-proof, Division 2
★
I6
CSA Intrinsically Safe
★
IF
CSA FISCO Intrinsically Safe (FOUNDATION Fieldbus protocol only)
★
K6(20)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
E7
IECEx Flameproof, Dust Ignition-proof
★
I7
IECEx Intrinsic Safety
★
IG
IECEx FISCO Intrinsic Safety (FOUNDATION Fieldbus protocol only)
★
N7
IECEx Type n
★
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n
★
E2
INMETRO Flameproof
★
I2
INMETRO Intrinsic Safety
★
IB
INMETRO FISCO Intrinsic Safety
★
K2
INMETRO Flameproof, Intrinsic Safety
★
E3
China Flameproof
★
I3
China Intrinsic Safety
★
N3
China Type n
★
18
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 2. Rosemount 3051S Scalable In-line Pressure Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
EP
Korea Flameproof
★
IP
Korea Intrinsic Safety
★
KP
Korea Flameproof, Intrinsic Safety
★
EM
Technical Regulations Customs Union (EAC) Flameproof
★
IM
Technical Regulations Customs Union (EAC) Intrinsic Safety
★
KM
Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety
★
KA(20)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2
★
KB(20)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2
★
KD(20)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe
★
KG
FM, CSA, ATEX and IECEx FISCO Intrinsic Safety
★
Shipboard approvals
SBS
American Bureau of Shipping
★
SBV
Bureau Veritas (BV) Type Approval
★
SDN
Det Norske Veritas (DNV) Type Approval
★
SLL
Lloyds Register (LR) Type Approval
★
Sensor fill fluid(21)
L1
Inert sensor fill fluid
★
Display type(22)
M5
Plantweb LCD display
★
M7(14)(23)(24)
Remote mount LCD display and interface, Plantweb housing, no cable, SST bracket
★
M8(14)(23)(25)
Remote mount LCD display and interface, Plantweb housing, 50 ft. (15 m) cable, SST bracket
★
M9(14)(23)(25)
Remote mount LCD display and interface, Plantweb housing, 100 ft. (31 m) cable, SST bracket
★
Pressure testing
P1
Hydrostatic testing with certificate
Special cleaning(25)
P2
Cleaning for special services
P3
Cleaning for special services with testing for <1PPM chlorine/fluorine
Calibration certification
Q4
Calibration certificate
★
QP
Calibration certificate and tamper evident seal
★
Material traceability certification
Q8
Material traceability certification per EN 10204 3.1
Emerson.com/Rosemount
★
19
Rosemount 3051S Series
October 2017
Table 2. Rosemount 3051S Scalable In-line Pressure Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Quality certification for safety(26)
QS
Prior-use certificate of FMEDA data
★
QT
Safety-certified to IEC 61508 with certificate of FMEDA data
★
Transient protection(27)(28)
T1
★
Transient terminal block
Drinking water approval(29)
DW
★
NSF drinking water approval
Surface finish certification
Q16
★
Surface finish certification for sanitary remote seals
Toolkit total system performance reports
QZ
★
Remote seal system performance calculation report
Conduit electrical connector(30)
GE
M12, 4-pin, male connector (eurofast)
★
GM
A size mini, 4-pin, male connector (minifast)
★
NACE certificate(31)
Q15
Certificate of compliance to NACE MR0175/ISO 15156 for wetted materials
★
Q25
Certificate of compliance to NACE MR0103 for wetted materials
★
Typical model number:
3051S1TG 2A 2 E11 A 1A DA2 B4 M5
1.
For detailed specifications see “Specifications” on page 104.
2.
Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
Order with Q15 or Q25 to receive a NACE certificate.
3.
Isolator diaphragm selection will dictate materials of construction for wetted parts.
4.
“Assemble to” items are specified separately and require a completed model number.
5.
Consult an Emerson representative for performance specifications.
6.
Requires Plantweb housing.
7.
Only intrinsically safe approval codes apply.
8.
Only available with output code X.
9.
Only available with output code A. Available approvals are FM Intrinsically Safe; Nonincendive (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic
Safety (option code I1), or IECEx Intrinsic Safety (option code I7). Contact an Emerson representative for additional information.
10.
Long-Life Power Module must be shipped separately, order Power Module 701PBKKF.
11.
Option HR7 configures the HART output to HART Revision 7. This option requires the selection of the Advanced Diagnostics (DA2) option. The device with this option
can be field configured to HART Revision 5 or 7 if desired.
12.
Requires Plantweb housing and output code A. Includes Hardware Adjustments as standard.
13.
Not available with output code F.
14.
Not available with output code X.
15.
Not available with housing style codes 00, 01, 2E, 2F, 2G, 2M, 5A, 5J, or 7J.
16.
Requires Plantweb housing and Hardware Adjustments option code D1. Limited availability depending on transmitter type and range. Contact an Emerson
representative for additional information.
17.
This assembly is included with options EP, KP, E1, N1, K1, ND, E4, E7, N7, K7, E2, E3, KA, KC, KD, IA, IB, IE, IF, IG, KG, T1, K2, N3, EM, and KM.
20
Emerson.com/Rosemount
October 2017
18.
Rosemount 3051S Series
Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
19.
Valid when SuperModule Platform and housing have equivalent approvals.
20.
Not available with M20 or G 1/2 conduit entry size.
21.
Silicone fill fluid is standard.
22.
Not available with Housing code 7J.
23.
Not available with output code F, option code DA2, or option code QT.
24.
See the Rosemount 3051S Reference Manual for cable requirements. Contact an Emerson representative for additional information.
25.
Not available with process connection option code A11.
26.
Not available with output code F or X. Not available with housing code 7J.
27.
Not available with Housing code 00, 5A, 5J, or 7J.
28.
The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IB, IE, IF, IG, and KG.
29.
Requires 316L SST diaphragm material and Process Connection code E11 or G11.
30.
Not available with Housing code 00, 5A, 5J, or 7J. Available with Intrinsically Safe approvals only. For FM Intrinsically Safe; Nonincendive (option code I5) or FM FISCO
Intrinsically Safe (option code IE), install in accordance with Rosemount drawing 03151-1009. Suitable for use with all IS approvals (I1, I2, I3, I5, I6, I7, IA, IB, IE, IF,
IG, IP, IM, KG).
31.
NACE compliant wetted materials are identified by Footnote 2.
Emerson.com/Rosemount
21
Rosemount 3051S Series
October 2017
Rosemount 3051S MultiVariable Transmitter
The Rosemount 3051S MultiVariable Transmitter delivers unprecedented performance
and capabilities by providing superior flow calculations including fully compensated
mass or volume, energy, and totalized flow. Specify the level of compensation that best
matches the application:
Rosemount 3051S MultiVariable Transmitter

Gas, natural gas, and steam measurement: Utilize full compensation (differential
pressure, line pressure, and temperature measurement)

Saturated steam: Utilize differential and line pressure, or differential pressure and
temperature measurement

Liquids: Utilize differential pressure and temperature measurement

Liquids at stable temperatures: Utilize differential pressure measurement

4–20 mA HART, WirelessHART, FOUNDATION Fieldbus protocols
Additional information
Specifications: page 104
Certifications: page 139
Dimensional drawings: page 145
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 124 for more information on material selection.
Table 3. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Model
Transmitter type
3051SMV
Scalable multivariable transmitter
Performance class(1)
Measurement Types 1 and 2
3(2)
Ultra for Flow: 0.04% reading DP accuracy, 200:1 rangedown,15-year stability, 15-year limited warranty
★
5
Classic MV: 0.04% span DP accuracy, 100:1 rangedown, 15-year stability
★
Measurement Types 3 and 4
1
Ultra: 0.025% span DP accuracy, 200:1 rangedown, 15-year stability, 15-year limited warranty
★
2
Classic: 0.035% span DP accuracy, 150:1 rangedown, 15-year stability
★
3(2)
Ultra for Flow: 0.04% reading DP accuracy, 200:1 rangedown,15-year stability, 15-year limited warranty
★
Multivariable type
M
Measurement with fully compensated mass and energy(3) flow calculations
★
P
Measurement of process variables only (no flow calculations)
★
Measurement type
1
Differential pressure, static pressure, and temperature
★
2
Differential pressure and static pressure
★
3
Differential pressure and temperature
★
4
Differential pressure
★
22
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 3. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Differential pressure range(4)
0(5)
–3 to 3 inH2O (–7,46 to 7,46 mbar)
★
1
–25 to 25 inH2O (–62,16 to 62,16 mbar)
★
2
–250 to 250 inH2O (–621,60 to 621,60 mbar)
★
3
–1000 to 1000 inH2O (–2,48 to 2,48 bar)
★
4
–150 to 150 psi (–10,34 to 10,34 bar) for measurement types 1 and 2;
–300 to 300 psi (–20,68 to 20,68 bar) for measurement types 3 and 4
★
5
–2000 to 2000 psi (–137,89 to 137,89 bar)
★
Static pressure type
N(6)
None
★
A
Absolute
★
G
Gage
★
Static pressure range
Absolute
Gage
N(6)
None
N/A
N/A
★
3
Range 3
0.5 to 800 psia (0,03 to 55,15 bar)
–14.2 to 800 psig (–0,98 to 55,15 bar)
★
4(7)
Range 4
0.5 to 3626 psia (0,03 to
250,00 bar)
–14.2 to 3626 psig (–0,98 to
250,00 bar)
★
Temperature input
N(8)
None
★
R(9)
RTD input (type Pt 100, –328 to 1562 °F [–200 to 850 °C])
★
Isolating diaphragm
2(10)
316L SST
★
3(10)
Alloy C-276
★
5(11)
Tantalum
7(10)
Gold-plated 316L SST
Material type
Process connection
Size
000
None (no process flange)
A11(12)
Flange
material
Drain vent
Bolting
N/A
N/A
N/A
N/A
★
Assemble to Rosemount
305/306 integral manifold
N/A
N/A
N/A
N/A
★
A12(12)
Assemble to Rosemount 304 or
AMF manifold with SST
traditional flange
N/A
N/A
N/A
N/A
★
A15(12)
Assemble to Rosemount 304 or
AMF manifold to SST traditional
flange with Alloy C-276 drain
vents
N/A
N/A
N/A
N/A
★
Emerson.com/Rosemount
23
Rosemount 3051S Series
October 2017
Table 3. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
A16(12)
Assemble to 304 or AMF
manifold to DIN SST traditional
flange
N/A
N/A
N/A
N/A
★
A22
Assemble AMF manifold to SST
coplanar flange
N/A
N/A
N/A
N/A
★
B11(12)(13)
Assemble to one Rosemount
1199 seal
N/A
N/A
N/A
N/A
★
B12(12)(13)
Assemble to two Rosemount
1199 seals
N/A
N/A
N/A
N/A
★
C11(12)
Assemble to Rosemount 405C or
405P primary element
N/A
N/A
N/A
N/A
★
D11(12)
Assemble to Rosemount 1195
integral orifice and Rosemount
305 integral manifold
N/A
N/A
N/A
N/A
★
EA2(12)
Assemble to Rosemount 485 or
405A Annubar primary element
with coplanar flange
N/A
SST
316 SST
N/A
★
EA3(12)
Assemble to Rosemount 485 or
405A Annubar primary element
with coplanar flange
N/A
Cast C-276
Alloy C-276
N/A
★
EA5(12)
Assemble to Rosemount 485 or
405A Annubar primary element
with coplanar flange
N/A
SST
Alloy C-276
N/A
★
E11
Coplanar flange
1 4
/ –18 NPT
Carbon steel
316 SST
N/A
★
E12
Coplanar flange
1 4
/ –18 NPT
SST
316 SST
N/A
★
E13(10)
Coplanar flange
1 4
/ –18 NPT
Cast C-276
Alloy C-276
N/A
★
E14
Coplanar flange
1 4
/ –18 NPT
Cast Alloy 400
Alloy 400/K-500
N/A
★
E15(10)
Coplanar flange
1 4
/ –18 NPT
SST
Alloy C-276
N/A
★
E16(10)
Coplanar flange
1 4
/ –18 NPT
Carbon steel
Alloy C-276
N/A
★
E21
Coplanar flange
RC /
Carbon steel
316 SST
N/A
★
E22
Coplanar flange
RC /
SST
316 SST
N/A
★
E23(10)
Coplanar flange
RC 1/4
Cast C-276
Alloy C-276
N/A
★
E24
Coplanar flange
RC 1/4
Cast Alloy 400
Alloy 400/K-500
N/A
★
E25(10)
Coplanar flange
RC /
SST
Alloy C-276
N/A
★
E26(10)
Coplanar flange
RC /
Carbon steel
Alloy C-276
N/A
★
F12
Traditional flange
1 4
/ –18 NPT
SST
316 SST
N/A
★
F13(10)
Traditional flange
1 4
/ –18 NPT
Cast C-276
Alloy C-276
N/A
★
F14
Traditional flange
1 4
/ –18 NPT
Cast Alloy 400
Alloy 400/K-500
N/A
★
F15(10)
Traditional flange
1 4
/ –18 NPT
SST
Alloy C-276
N/A
★
F22
Traditional flange
RC 1/4
SST
316 SST
N/A
★
F23(10)
Traditional flange
RC 1/4
Cast C-276
Alloy C-276
N/A
★
F24
Traditional flange
RC /
Cast Alloy 400
Alloy 400/K-500
N/A
★
24
1 4
1 4
1 4
1 4
1 4
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 3. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
N/A
★
/ -in. bolting
★
N/A
N/A
★
SST
N/A
N/A
★
2-in. ANSI Class 150
Cast C-276
N/A
N/A
★
Vertical mount level flange
2-in. ANSI Class 300
Cast C-276
N/A
N/A
★
G21
Vertical mount level flange
3-in. ANSI Class 150
SST
N/A
N/A
★
G22
Vertical mount level flange
3-in. ANSI Class 300
SST
N/A
N/A
★
G31
Vertical mount level flange
DIN- DN 50 PN 40
SST
N/A
N/A
★
EB6
Assemble to primary element
with manifold and coplanar
flange, CS, Alloy C-276
N/A
N/A
N/A
N/A
F32
Bottom vent traditional flange
/ –18 NPT
SST
316 SST
N/A
F42
Bottom vent traditional flange
SST
316 SST
N/A
F62
DIN-compliant traditional flange
1 4
/ –18 NPT
SST
316 SST
M10 bolting
F72
DIN-compliant traditional flange
1 4
/ –18 NPT
SST
316 SST
M12 bolting
G41
Vertical mount level flange
DIN- DN 80 PN 40
SST
N/A
N/A
F25(10)
Traditional flange
F52
DIN-compliant traditional flange
G11
RC 1/4
SST
Alloy C-276
/ –18 NPT
SST
316 SST
Vertical mount level flange
2-in. ANSI Class 150
SST
G12
Vertical mount level flange
2-in. ANSI Class 300
G14(10)
Vertical mount level flange
G15(10)
1 4
1 4
RC /
1 4
7 16
Transmitter output
A
4–20 mA with digital signal based on HART protocol
★
X(14)
Wireless (requires wireless options and wireless Plantweb housing)
★
F(15)
FOUNDATION Fieldbus
★
Housing style
Material
Conduit entry size
1A
Plantweb housing
Aluminum
1 2
/ –14 NPT
★
1B
Plantweb housing
Aluminum
M20 ⫻ 1.5
★
1J
Plantweb housing
SST
1 2
/ –14 NPT
★
1K
Plantweb housing
SST
M20 ⫻ 1.5
★
5A(16)
Wireless Plantweb housing
Aluminum
1 2
/ –14 NPT
★
5J(16)
Wireless Plantweb housing
SST
1 2
/ –14 NPT
★
1C
Plantweb housing
Aluminum
G1/2
1L
Plantweb housing
SST
G1/2
Wireless options (requires option code X and wireless Plantweb housing)
Update rate
WA
User configurable update rate
★
Operating frequency and protocol
3
2.4 GHz DSSS, IEC 62591 (WirelessHART)
Emerson.com/Rosemount
★
25
Rosemount 3051S Series
October 2017
Table 3. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Omni-directional wireless antenna
WK
External antenna
★
WM
Extended range, external antenna
★
WN
High-gain, remote antenna
SmartPower(17)
1
Adapter for Black Power Module (I.S. Power Module sold separately)
★
Other options (include with selected model number)
Extended product warranty
WR3
3-year limited warranty
★
WR5
5-year limited warranty
★
RTD cable (RTD sensor must be ordered separately)
C12
RTD Input with 12 ft. (3,66 m) of shielded cable
★
C13
RTD Input with 24 ft. (7,32 m) of shielded cable
★
C14
RTD Input with 75 ft. (22,86 m) of shielded cable
★
C22
RTD Input with 12 ft. (3,66 m) of armored shielded cable
★
C23
RTD Input with 24 ft. (7,32 m) of armored shielded cable
★
C24
RTD Input with 75 ft. (22,86 m) of armored shielded cable
★
C32
RTD Input with 12 ft. (3,66 m) of ATEX/IECEx Flameproof cable
★
C33
RTD Input with 24 ft. (7,32 m) of ATEX/IECEx Flameproof cable
★
C34
RTD Input with 75 ft. (22,86 m) of ATEX/IECEx Flameproof cable
★
Plantweb control functionality
A01
FOUNDATION Fieldbus advanced control function block suite
★
Mounting brackets(18)
B4
Coplanar flange bracket, all SST, 2-in. pipe and panel
★
B1
Traditional flange bracket, Carbon steel, 2-in. pipe
★
B2
Traditional flange bracket, Carbon steel, panel
★
B3
Traditional flange flat bracket, Carbon steel, 2-in. pipe
★
B7
Traditional flange bracket, B1 with SST bolts
★
B8
Traditional flange bracket, B2 with SST bolts
★
B9
Traditional flange bracket, B3 with SST bolts
★
BA
Traditional flange bracket, B1, all SST
★
BC
Traditional flange bracket, B3, all SST
★
26
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 3. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Software configuration
C1(19)
Custom software configuration (Rosemount 3051SMV Configuration Data Sheet must be completed.)
★
C2(20)
Custom flow configuration (Rosemount 3051SMV Wireless Configuration Data Sheet must be completed for
HART devices or Rosemount 3051SMV Configuration Data Sheet for Fieldbus devices.)
★
C4(19)(20)
NAMUR alarm and saturation levels, high alarm
★
C5(19)(20)
NAMUR alarm and saturation levels, low alarm
★
C6(19)(20)
Custom alarm and saturation signal levels, high alarm
★
C7(19)(20)
Custom alarm and saturation signal levels, low alarm
★
C8(19)(20)
Low alarm (standard Rosemount alarm and saturation levels)
★
Flange adapter(21)
D2
1 2
/ –14 NPT flange adapter
D9
RC 1/2 SST flange adapter
★
Ground screw(22)
D4
External ground screw assembly
★
Drain/vent valve(21)
D5
Delete transmitter drain/vent valves (install plugs)
D7
Coplanar flange without drain/vent ports
★
Conduit plug(23)
DO
316 SST conduit plug
★
Product certifications
E1
ATEX Flameproof
★
I1
ATEX Intrinsic Safety
★
IA(24)
ATEX FISCO Intrinsic Safety
★
N1
ATEX Type n
★
ND
ATEX Dust
★
K1
ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E1, I1, N1, and ND)
★
E4
TIIS Flameproof
★
E5
FM Explosion-proof, Dust Ignition-proof
★
I5
FM Intrinsically Safe; Nonincendive
★
IE(24)
FM FISCO Intrinsic Safety
★
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5 and I5)
★
E6(25)
CSA Explosion-proof, Dust Ignition-proof, Division 2
★
I6
CSA Intrinsically Safe
★
IF(24)
CSA FISCO Intrinsic Safety
★
K6(25)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E6 and I6)
★
Emerson.com/Rosemount
27
Rosemount 3051S Series
October 2017
Table 3. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
E7
IECEx Flameproof, Dust Ignition-proof
★
I7
IECEx Intrinsic Safety
★
IG(24)
IECEx FISCO Intrinsic Safety
★
N7
IECEx Type n
★
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of E7, I7, and N7)
★
E2
INMETRO Flameproof
★
I2
INMETRO Intrinsic Safety
★
E3
China Flameproof
★
I3
China Intrinsic Safety
★
EM
Technical Regulations Customs Union (EAC) Flameproof
★
IM
Technical Regulations Customs Union (EAC) Intrinsic Safety
★
KM
Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety
★
KA(25)(26)
ATEX and CSA Explosion-proof, Intrinsically Safe, Division 2 (combination of E1, E6, I1, and I6)
★
KB(25)(26)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5, E6, I5, and I6)
★
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2 (combination of E5, E1, I5, and I1)
★
KD(25)(26)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of E5, E6, E1, I5, I6, and I1)
★
KG(24)
ATEX, FM, CSA, and IECEx FISCO Intrinsic Safety (combination of IA, IE, IF, and IG)
★
Drinking water approval(27)
DW
★
NSF drinking water certification
Shipboard approvals(19)
SBS
American Bureau of Shipping
★
SBV
Bureau Veritas (BV) Type Approval
★
SDN
Det Norske Veritas (DNV) Type Approval
★
SLL
Lloyds Register (LR) Type Approvals
★
Alternate materials of construction
L1
Inert sensor fill fluid (differential and gage sensors only) Note: Silicone fill fluid is standard.
★
L2
Graphite-filled PTFE O-ring
★
L4(21)
Austenitic 316 SST bolts
★
L5(21)
ASTM A193, Grade B7M bolts
★
L6(21)
Alloy K-500 bolts
★
L7(21)(28)
ASTM A453, Class D, Grade 660 bolts
★
L8(21)
ASTM A193, Class 2, Grade B8M bolts
★
Digital display
M5
28
Plantweb LCD display
★
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 3. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Wireless assembly options(3)
WTA
Integral assembly to Wireless THUM™ Adapter (specified separately)
★
Special procedures
P1(29)
Hydrostatic testing with certificate
★
P9(30)(31)
4500 psig (310 bar) static pressure limit
★
P0(30)(32)
6092 psig (420 bar) static pressure limit
★
P2(21)
Cleaning for special services
P3(21)
Cleaning for special services with testing for <1PPM chlorine/fluorine
Special certifications
Q4
Calibration Certificate
★
QP
Calibration Certificate and Tamper Evident Seal
★
Q8
Material Traceability Certification per EN 10204 3.1B
★
Q16
Surface Finish Certification for Sanitary Remote Seals
★
QZ
Remote seal system performance calculation report
★
Quality certification for safety(33)
QS
Prior-use certification of FMEDA data
★
QT
Safety certified to IEC 61508 with certification of FMEDA data
★
Transient protection(34)
T1
Transient terminal block
★
Conduit electrical connector(35)
GE
M12, 4-pin, male connector (eurofast)
★
GM
A size mini, 4-pin, male connector (minifast)
★
NACE certificate(36)
Q15
Certificate of compliance to NACE MR0175/ISO 15156 for wetted materials
★
Q25
Certificate of compliance to NACE MR0103 for wetted materials
★
Cold temperature(19)
BRR
–58 °F (–50 °C) cold temperature start-up
Typical model number:
3051SMV 3 M 1 2 G 4 R 2 E12 A 1A B4 C2 M5
1.
For detailed specifications see “Specifications” on page 104.
2.
For Measurement Types 1 and 2, only available with DP range codes 2, 3, and 4, 316L SST and Alloy C-276 isolating diaphragm and silicone fill fluid.
For Measurements Types 3 and 4, only available with DP range codes 2 and 3, 316L SST and Alloy C-276 isolating diaphragm and silicone fill fluid.
3.
Only available with Transmitter output code A.
4.
If ordering measurement type code M, DP Range 4 and 5 are not available.
5.
DP Range 0 is only available with Measurement Type 3 or 4 and traditional flange, 316L SST diaphragm material, and Bolting option L4.
6.
Required for Measurement Type codes 3 and 4.
Emerson.com/Rosemount
★
29
Rosemount 3051S Series
7.
October 2017
For Measurement Type codes 1 and 2 with DP range 1, absolute limits are 0.5 to 2000 psi (0,03 to 137,9 bar) and gage limits are –14.2 to 2000 psig
(–0,98 to 137,9 bar).
8.
Required for Measurement Type codes 2 and 4.
9.
Required for Measurement Type codes 1 and 3. RTD Sensor must be ordered separately.
10.
Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
Order with Q15 or Q25 to receive a NACE certificate.
11.
Tantalum diaphragm material is only available for DP ranges 2-5.
12.
“Assemble to” items are specified separately and require a completed model number.
13.
Consult an Emerson representative for performance specifications.
14.
Only available with Measurement Type 2 and multivariable type P.
15.
Transmitter output code F is not available with Performance Class 1 and 2 and Measurement Type 3 and 4.
16.
Only available with output code X.
17.
Long-Life Power Module must be shipped separately, order Power Module 701PBKKF.
18.
For process connection option code A11, the mounting bracket must be ordered as part of the manifold model number.
19.
Not available with transmitter output code F.
20.
Not available with transmitter output code X.
21.
Not available with process connection option code A11.
22.
This assembly is included with certification options EP, KP, E1, N1, K1, ND, E4, E7, N7, K7, E2, E3, KA, KC, KD, EM, KM, IA, IE, IF, IG, KG.
23.
Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
24.
FISCO is only available with transmitter output code F.
25.
Not available with M20 or G 1/2 conduit entry size.
26.
RTD cable not available with this option.
27.
Requires 316L SST diaphragm material, glass-filled PTFE O-ring (standard), and Process Connection code E12 or F12.
28.
Bolts are not considered process wetted. In instances where NACE MR0175/ISO 15156 and NACE MR0103 conformance is required for bolting, L7 is the
recommended bolting option.
29.
Not available with DP range 0.
30.
Only available with Measurement Type codes 3 and 4.
31.
When assembled to remote diaphragm seal system using B11 or B12 process connections, the maximum working pressure of the system may be limited by the
rating of the Rosemount 1199 Seal System selected.
32.
Requires 316L SST or Alloy C-276 diaphragm material, assemble to Rosemount 305 Integral Manifold or DIN-compliant traditional flange process connection, and
bolting option L8. Limited to differential pressure ranges 2-5.
33.
Not available with output code F or X.
34.
The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IB, IE, IF, IG, and KG.
35.
Available with Intrinsically Safe approvals only. For FM Intrinsically Safe; Nonincendive approval (option code I5), install in accordance with Rosemount drawing
03151-1009.
36.
NACE compliant wetted materials are identified by Footnote 10.
30
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Rosemount 3051SF DP Flowmeters
Rosemount 3051SF Flowmeters integrate the Rosemount 3051S with industry leading
primary elements. Capabilities include:
Rosemount
3051SFC
Rosemount
3051SFA

Flowmeters are factory configured to meet your application needs (Configuration Data
Sheet required)

Multivariable capabilities allow scalable flow compensation (Measurement Types 1–4)

4–20 mA HART, Wireless, and FOUNDATION Fieldbus protocols

Ultra for Flow for improved flow performance across wider flow ranges

Integral temperature measurement (Option code T)

Advanced Diagnostics (Option code DA2)

Direct or remote mount configurations available
Additional information
Rosemount
3051SFP
Specifications: page 104
Dimensional drawings: page 152
Rosemount 3051SFA Annubar Flowmeter

Annubar flowmeters reduce permanent pressure loss by creating less blockage in the pipe

Ideal for large line size installations when cost, size and weight of the flowmeter are concerns
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 124 for more information on material selection.
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
• = Available
— = Unavailable
Model
3051SFA
Product description
Annubar flowmeter
Measurement
type
D
1-7
•
•
Measurement type
1
Fully compensated mass and energy(1) flow calculations – differential and static pressures
with temperature
—
•
★
2
Compensated flow calculations – differential and static pressures
—
•
★
3
Compensated flow calculations – differential pressure and temperature
—
•
★
4
Compensated flow calculations – differential pressure
—
•
★
D
Differential pressure
•
—
★
5
Process variables only (no flow calculations) – differential and static pressures with
temperature
—
•
★
6
Process variables only (no flow calculations) – differential and static pressures
—
•
★
7
Process variables only (no flow calculations) – differential pressure and temperature
—
•
★
Emerson.com/Rosemount
31
Rosemount 3051S Series
October 2017
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Fluid type
L
Liquid
•
•
★
G
Gas
•
•
★
S
Steam
•
•
★
020
2-in. (50 mm)
•
•
★
025
21/2-in. (63,5 mm)
•
•
★
030
3-in. (80 mm)
•
•
★
035
3 / -in. (89 mm)
•
•
★
040
4-in. (100 mm)
•
•
★
050
5-in. (125 mm)
•
•
★
060
6-in. (150 mm)
•
•
★
070
7-in. (175 mm)
•
•
★
080
8-in. (200 mm)
•
•
★
100
10-in. (250 mm)
•
•
★
120
12-in. (300 mm)
•
•
★
140
14-in. (350 mm)
•
•
160
16-in. (400 mm)
•
•
180
18-in. (450 mm)
•
•
200
20-in. (500 mm)
•
•
240
24-in. (600 mm)
•
•
300
30-in. (750 mm)
•
•
360
36-in. (900 mm)
•
•
420
42-in. (1066 mm)
•
•
480
48-in. (1210 mm)
•
•
600
60-in. (1520 mm)
•
•
720
72-in. (1820 mm)
•
•
780
78-in. (1950 mm)
•
•
840
84-in. (2100 mm)
•
•
900
90-in. (2250 mm)
•
•
960
96-in. (2400 mm)
•
•
Line size
1 2
Pipe I.D. range(2)
C
Range C from the Pipe I.D. table
•
•
★
D
Range D from the Pipe I.D. table
•
•
★
A
Range A from the Pipe I.D. table
•
•
32
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
B
Range B from the Pipe I.D. table
•
•
E
Range E from the Pipe I.D. table
•
•
Z
Non-standard Pipe I.D. Range or line sizes greater than 12-in. (300 mm)
•
•
Pipe material/mounting assembly material
C
Carbon steel (A105)
•
•
★
S
316 Stainless steel
•
•
★
0(3)
No mounting (customer supplied)
•
•
★
G
Chrome-Moly Grade F-11
•
•
N
Chrome-Moly Grade F-22
•
•
J
Chrome-Moly Grade F-91
•
•
Piping orientation
H
Horizontal piping
•
•
★
D
Vertical piping with downwards flow
•
•
★
U
Vertical piping with upwards flow
•
•
★
P
Pak-Lok
•
•
★
F
Flanged with opposite side support
•
•
★
L
Flange-Lok
•
•
G
Gear-Drive Flo-Tap
•
•
M
Manual Flo-Tap
•
•
Annubar type
Sensor material
★
S
316 Stainless steel
•
•
H
Alloy C-276
•
•
1
Sensor size 1 — Line sizes 2-in. (50 mm) to 8-in. (200 mm)
•
•
★
2
Sensor size 2 — Line sizes 6-in. (150 mm) to 96-in. (2400 mm)
•
•
★
3
Sensor size 3 — Line sizes greater than 12-in. (300 mm)
•
•
Sensor size
Mounting type
T1
Compression/threaded connection
•
•
★
A1
Class 150 RF ANSI
•
•
★
A3
Class 300 RF ANSI
•
•
★
A6
Class 600 RF ANSI
•
•
★
D1
DN PN16 flange
•
•
★
D3
DN PN40 flange
•
•
★
Emerson.com/Rosemount
33
Rosemount 3051S Series
October 2017
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
★
D6
DN PN100 flange
•
•
A9(4)
Class 900 RF ANSI
•
•
AF(4)
Class 1500 RF ANSI
•
•
AT(4)
Class 2500 RF ANSI
•
•
R1
Class 150 RTJ flange
•
•
R3
Class 300 RTJ flange
•
•
R6
Class 600 RTJ flange
•
•
R9(4)
Class 900 RTJ flange
•
•
RF(4)
Class 1500 RTJ flange
•
•
RT(4)
Class 2500 RTJ flange
•
•
•
•
★
Opposite side support or packing gland
0
No opposite side support or packing gland (required for Pak-Lok and Flange-Lok models)
Opposite side support (required for flanged models)
C
NPT threaded opposite support assembly (extended tip)
•
•
★
D
Welded opposite support assembly (extended tip)
•
•
★
Packing gland (required for Flo-Tap models)
Packing gland material
Rod material
Packing
material
J(5)
Stainless steel packing gland/cage nipple
Carbon steel
PTFE
•
•
K(5)
Stainless steel packing gland/cage nipple
Stainless steel
PTFE
•
•
L(5)
Stainless steel packing gland/cage nipple
Carbon steel
Graphite
•
•
N(5)
Stainless steel packing gland/cage nipple
Stainless steel
Graphite
•
•
R
Alloy C-276 packing gland/cage nipple
Stainless steel
Graphite
\•
•
Isolation valve for Flo-Tap models
0(3)
Not applicable or customer supplied
•
•
1
Gate valve, carbon steel
•
•
2
Gate valve, stainless steel
•
•
5
Ball valve, carbon steel
•
•
6
Ball valve, stainless steel
•
•
★
Temperature measurement
T(6)
Integral RTD (not available with flanged model greater than Class 600)
•
•
★
0(7)
No temperature sensor
•
•
★
R(6)
Remote thermowell and RTD
•
•
34
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Transmitter connection platform
3
Direct mount, integral 3-valve manifold
(not available with flanged model greater than Class 600)
•
•
★
5
Direct mount, 5-valve manifold (not available with flanged model greater than Class 600)
•
•
★
7
Remote mount NPT connections (1/2-in. FNPT)
•
•
★
6
Direct mount, high temperature 5-valve manifold (not available with flanged model greater
than Class 600)
•
•
8
Remote mount SW connections (1/2-in.)
•
•
Differential pressure range
1
0 to 25 inH2O (0 to 62,16 mbar)
•
•
★
2
0 to 250 inH2O (0 to 621,60 mbar)
•
•
★
3
0 to 1000 inH2O (0 to 2,48 bar)
•
•
★
Static pressure range
A(8)
None
•
•
★
D
Absolute (0 to 800 psia [0 to 55,15 bar])
—
•
★
E(9)
Absolute (0 to 3626 psia [0 to 250,00 bar])
—
•
★
J
Gage (–14.2 to 800 psig [–0,98 to 55,15 bar])
—
•
★
K(9)
Gage (–14.2 to 3626 psig [–0,98 to 250,00 bar])
—
•
★
Transmitter output
A
4–20 mA with digital signal based on HART protocol
•
•
★
F(10)
FOUNDATION Fieldbus protocol (requires Plantweb housing)
•
•
★
X(11)(12)
Wireless (requires wireless options and Wireless Plantweb housing)
•
•
★
Transmitter housing style
Material
Conduit entry
size
N/A
N/A
•
—
★
1 2
/ –14 NPT
•
•
★
00
None (customer-supplied electrical connection)
1A
Plantweb housing
Aluminum
1B
Plantweb housing
Aluminum
1J
Plantweb housing
1K
Plantweb housing
2A
Junction box housing
Aluminum
2B
Junction box housing
2E
M20 ⫻ 1.5
•
•
★
SST
1 2
/ –14 NPT
•
•
★
SST
M20 ⫻ 1.5
•
•
★
1 2
/ –14 NPT
•
—
★
Aluminum
M20 ⫻ 1.5
•
—
★
Junction box housing with output for remote display and
interface
Aluminum
1 2
/ –14 NPT
•
—
★
2F
Junction box housing with output for remote display and
interface
Aluminum
M20 ⫻ 1.5
•
—
★
2J
Junction box housing
/ –14 NPT
•
—
★
Emerson.com/Rosemount
SST
1 2
35
Rosemount 3051S Series
October 2017
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
2M
Junction box housing with output for remote display and
interface
5A(13)
/ –14 NPT
•
—
★
/ –14 NPT
•
•
★
/ –14 NPT
•
•
★
N/A
N/A
•
—
★
Plantweb housing
Aluminum
G1/2
•
•
1L
Plantweb housing
SST
G1/2
•
•
2C
Junction box housing
Aluminum
G1/2
•
—
2G
Junction box housing with output for remote display and
interface
Aluminum
G1/2
•
—
SST
1 2
Wireless Plantweb housing
Aluminum
1 2
5J(13)
Wireless Plantweb housing
SST
1 2
7J(11)(14)
Quick Connect (A size mini, 4-pin male termination)
1C
Performance class(15)
Measurement types 1, 2, 5, and 6
3(16)
Ultra for Flow: 0.8% flow rate accuracy, 14:1 flow turndown, 15-year stability, 15-year limited
warranty
•
•
★
5
Classic MV: 1.15% flow rate accuracy, 8:1 flow turndown, 15-yr. stability
—
•
★
Measurement types 3, 4, 7, and D
1
Ultra: up to 0.95% flow rate accuracy, 8:1 flow turndown, 15-year stability, 15-year limited
warranty
•
—
★
2
Classic: up to 1.4% flow rate accuracy, 8:1 flow turndown, 15-year stability
•
—
★
3(16)
Ultra for Flow: 0.8% flow rate accuracy, 14:1 flow turndown, 15-year stability, 15-year limited
warranty
•
•
★
•
—
★
•
—
★
Wireless options (requires option code X and wireless Plantweb housing)
Update rate, operating frequency and protocol
WA
User configurable update rate
Operating frequency and protocol
3
2.4 GHz DSSS, IEC 62591 (WirelessHART)
Omni-directional wireless antenna
WK
External antenna
•
—
★
WM
Extended range, external antenna
•
—
★
WN
High-gain, remote antenna
•
—
•
—
★
•
—
★
SmartPower(17)
1
Adapter for Black Power Module (I.S. Power Module sold separately)
Other options (include with selected model number)
HART Revision configuration (requires HART Protocol output code A)(18)
HR7
36
Configured for HART Revision 7
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Extended product warranty
WR3
3-year limited warranty
•
•
★
WR5
5-year limited warranty
•
•
★
Pressure testing(19)
P1
Hydrostatic testing with certificate
•
•
PX
Extended hydrostatic testing
•
•
Special cleaning
P2
Cleaning for special services
•
•
PA
Cleaning per ASTM G93 level D (section 11.4)
•
•
•
•
•
•
Material testing
V1
Dye penetrant exam
Material examination
V2
Radiographic examination
Flow calibration
W1
Flow calibration (average K)
•
•
WZ
Special calibration
•
•
Special inspection
QC1
Visual and dimensional inspection with certificate
•
•
★
QC7
Inspection and performance certificate
•
•
★
RL
Surface finish for low pipe Reynolds number in gas and steam
•
•
★
RH
Surface finish for high pipe Reynolds number in liquid
•
•
★
•
•
★
Surface finish
Material traceability certification(20)
Q8
Material Traceability Certificate per EN 10204:2004 3.1
Code conformance(21)
J2
ANSI/ASME B31.1
•
•
J3
ANSI/ASME B31.3
•
•
•
•
Material conformance(22)
J5
NACE MR-0175/ISO 15156
Country certification
J6
European Pressure Directive (PED)
•
•
J1
Canadian Registration
•
•
Emerson.com/Rosemount
★
37
Rosemount 3051S Series
October 2017
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Installed in flanged pipe spool section
H3
Class 150 flanged connection with Rosemount standard length and schedule
•
•
H4
Class 300 flanged connection with Rosemount standard length and schedule
•
•
H5
Class 600 flanged connection with Rosemount standard length and schedule
•
•
Instrument connections for remote mount option
G2
Needle valves, Stainless steel
•
•
★
G6
OS and Y gate valve, Stainless steel
•
•
★
G1
Needle valves, Carbon steel
•
•
G3
Needle valves, Alloy C-276
•
•
G5
OS and Y gate valve, Carbon steel
•
•
G7
OS and Y gate valve, Alloy C-276
•
•
•
•
Special shipment
Y1
Mounting hardware (shipped separately)
★
Special dimensions
VM
Variable mounting
•
•
VT
Variable tip
•
•
VS
Variable length spool section
•
•
Transmitter calibration certification
Q4
Calibration certificate for transmitter
•
•
★
QP
Calibration certificate and tamper evident seal
•
•
★
Quality certification for safety(1)
QS
Prior-use certificate of FMEDA data
•
—
★
QT(26)
Safety certified to IEC 61508 with certificate of FMEDA data
•
—
★
Product certifications
E1
ATEX Flameproof
•
•
★
I1
ATEX Intrinsic Safety
•
•
★
IA(23)
ATEX FISCO Intrinsic Safety
•
•
★
N1
ATEX Type n
•
•
★
ND
ATEX Dust
•
•
★
K1
ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E1, I1, N1, and ND)
•
•
★
E4
TIIS Flameproof
•
•
★
E5
FM Explosion-proof, Dust Ignition-proof
•
•
★
I5
FM Intrinsically Safe; Nonincendive
•
•
★
IE(23)
FM FISCO Intrinsic Safety
•
•
★
38
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
(combination of E5 and I5)
•
•
★
E6(24)
CSA Explosion-proof, Dust Ignition-proof, Division 2
•
•
★
I6
CSA Intrinsically Safe
•
•
★
IF(23)
CSA FISCO Intrinsic Safety
•
•
★
K6(24)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
(combination of E6 and I6)
•
•
★
E7
IECEx Flameproof, Dust Ignition-proof
•
•
★
I7
IECEx Intrinsic Safety
•
•
★
IG(23)
IECEx FISCO Intrinsic Safety
•
•
★
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n
(combination of E7, I7, and N7)
•
•
★
E3
China Flameproof
•
•
★
EM
Technical Regulations Customs Union (EAC) Flameproof
•
•
★
IM
Technical Regulations Customs Union (EAC) Intrinsic Safety
•
•
★
KM
Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety
•
•
★
KG(23)
ATEX, FM, CSA, and IECEx FISCO Intrinsic Safety (combination of IA, IE, IF, and IG)
•
•
★
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2 (combination of E5, E1, I5, and I1)
•
•
KD(24)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe
(combination of E5, I5, E6, I6, E1, and I1)
•
•
Shipboard approvals(25)
SBS
American Bureau of Shipping
•
•
★
SBV
Bureau Veritas (BV) Type Approval
•
•
★
SDN
Det Norske Veritas (DNV) Type Approval
•
•
★
SLL
Lloyds Register (LR) Type Approval
•
•
★
Sensor fill fluid and O-ring options
L1
Inert sensor fill fluid
•
•
★
L2
Graphite-filled (PTFE) O-ring
•
•
★
LA
Inert sensor fill fluid and graphite-filled (PTFE) O-ring
•
•
★
Digital display(26)
M5
Plantweb LCD display (requires Plantweb housing)
•
•
★
M7(27)(28)(29)
Remote mount LCD display and interface, Plantweb housing, no cable; SST bracket
•
—
★
M8(27)(28)
Remote mount LCD display and interface, Plantweb housing, 50 ft (15 m) cable;
SST bracket
•
—
★
M9(27)(28)
Remote mount LCD display and interface, Plantweb housing, 100 ft (31 m) cable;
SST bracket
•
—
★
•
•
★
Transient protection(30)
T1
Transient terminal block
Emerson.com/Rosemount
39
Rosemount 3051S Series
October 2017
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Manifold for remote mount option
F2
3-valve manifold, stainless steel
•
•
★
F6
5-valve manifold, stainless steel
•
•
★
F1
3-valve manifold, carbon steel
•
•
F3
3-valve manifold, Alloy C-276
•
•
F5
5-valve manifold, carbon steel
•
•
F7
5-valve manifold, Alloy C-276
•
•
•
•
★
Plantweb control functionality
A01
FOUNDATION Fieldbus advanced control function block suite
Plantweb diagnostic functionality
D01
FOUNDATION Fieldbus diagnostics suite
•
—
★
DA2(31)
Advanced HART diagnostic suite
•
—
★
•
—
★
—
•
★
Plantweb enhanced measurement functionality
H01
FOUNDATION Fieldbus fully compensated mass flow block
Cold temperature(32)(33)
BRR
–58 °F (–50 °C) cold temperature start-up
Alarm limit(33)
C4
NAMUR alarm and saturation levels, high alarm
•
•
★
C5
NAMUR alarm and saturation levels, low alarm
•
•
★
C6
Custom alarm and saturation levels, high alarm
•
•
★
C7
Custom alarm and saturation levels, low alarm
•
•
★
C8
Low alarm (standard Rosemount alarm and saturation levels)
•
•
★
Hardware adjustments and ground screw
D1(27)(33)(34)
Hardware adjustments (zero, span, alarm, security)
•
—
★
D4(35)
External ground screw assembly
•
•
★
DA(27)(33)(34)
Hardware adjustments (zero, span, alarm, security) and external ground screw assembly
•
—
★
316 SST conduit plug
•
•
★
Conduit plug
DO
Conduit electrical connector(36)
GE
M12, 4-pin, male connector (eurofast)
•
•
★
GM
A size mini, 4-pin, male connector (minifast)
•
•
★
Typical model number: 3051SFA
1.
40
D
L
060
D
C
H
P
S
2
T1
0
0
0
3
2A
A
1A
3
For option code A: 4–20mA HART only.
Emerson.com/Rosemount
October 2017
2.
Rosemount 3051S Series
See the Rosemount DP Flowmeters and Primary Elements Product Data Sheet for Pipe I.D. table.
3.
Provide the “A” dimension for Flanged, Flange-Lok, and Threaded Flo-Tap models. Provide the “B” dimension for Flange Flo-Tap models.
4.
Available in remote mount applications only.
5.
The cage nipple is constructed of 304SST.
6.
Temperature Measurement Option code T or R is required for Measurement Type codes 1, 3, 5, and 7.
7.
Required for Measurement Type codes 2, 4, 6, and D.
8.
Required for Measurement Type codes 3, 4, 7, and D.
9.
For Measurement Type codes 1, 2, 5, and 6 with DP range 1, absolute limits are 0.5 to 2000 psi (0,03 to 137,9 bar) and gage limits are
-14.2 to 2000 psig (-0,98 to 137,9 bar).
10.
Transmitter output code F is only available with Measurement type code 1, 2, 5, 6, and D.
11.
Only intrinsically safe approval codes apply.
12.
Only available with Measurement Types D and 6.
13.
Only available with output code X.
14.
Only available with output code A.
15.
For detailed specifications see “Specifications” on page 104.
16.
Only available with differential pressure ranges 2 and 3, and silicone fill fluid.
17.
Long-life Power Module must be shipped separately, order Power Module 701PBKKF.
18.
Option HR7 configures the HART output to HART Revision 7. This option requires the selection of the Advanced Diagnostics (DA2) option. The device with this option
can be field configured to HART Revision 5 or 7 if desired.
19.
Applies to assembled flowmeter only, mounting not tested.
20.
Instrument Connections for Remote Mount Options and Isolation Valves for Flo-tap Models are not included in the Material Traceability Certification.
21.
Not available with Transmitter Connection Platform 6.
22.
Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits
apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
23.
FISCO is only available with Transmitter output code F.
24.
Not available with M20 or G 1/2 conduit entry size.
25.
Not available with transmitter output code F with Measurement Types 1, 2, 5, or 6.
26.
Not available with housing code 7J.
27.
Not available with output code X.Only available with Measurement Type D.
28.
Not available with output code F, option code DA2, or option code QT.
29.
See the Rosemount 3051S Reference Manual for cable requirements. Contact an Emerson representative for additional information.
30.
Not available with Housing code 5A, 5J, or 7J. External ground screw assembly (option code D4) is included with the T1 option. The T1 option is not needed with FISCO
Product Certifications.
31.
Includes Hardware Adjustments (option code D1) as standard. Not available with output code X or F. Only available with Measurement Type D.
32.
-58 °F (50 °C) for Measurement Type 1-7.
33.
Not available with output code F.
34.
Not available with housing codes 2E, 2F, 2G, 2M, 5A, 5J, or 7J.
35.
This assembly is included with options EP, KP, E1, N1, K1, ND, E4, E7, N7, K7, E2, E3, KA, KC, KD, IA, IE, N3, T1, EM, and KM.
36.
Not available with Housing code 5A, 5J, or 7J. Available with intrinsically Safe approvals only. For FM intrinsically Safe; Nonincendive (option code I5) or FM FISCO
Intrinsically Safe (option code IE), install in accordance with Rosemount drawing 03151-1009.
Emerson.com/Rosemount
41
Rosemount 3051S Series
October 2017
Rosemount 3051SFC Compact Flowmeter

Compact conditioning flowmeters reduce straight piping requirements to 2D upstream and 2D downstream
from most flow disturbances

Simple installation of compact flowmeters between any existing raised-face flanges
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 124 for more information on material selection.
Table 5. Rosemount 3051SFC Compact Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
• = Available
— = Unavailable
Model
3051SFC
Measurement
type
Product description
Compact orifice flowmeter
D
1-7
•
•
Measurement type
1(1)
Fully compensated mass and energy flow calculations – differential and static pressures w/
temperature
—
•
★
2
Compensated flow calculations – differential and static pressures
—
•
★
3
Compensated flow calculations – differential pressure and temperature
—
•
★
4
Compensated flow calculations – differential pressure
—
•
★
D
Differential pressure
•
—
★
5
Process variables only (no flow calculations) – differential and static pressures w/
temperature
—
•
★
6
Process variables only (no flow calculations)– differential and static pressures
—
•
★
7
Process variables only (no flow calculations) – differential pressure and temperature
—
•
★
Primary element technology
A
Annubar averaging pitot tube
•
•
★
C
Conditioning orifice plate
•
•
★
P
Orifice plate
•
•
★
316 SST
•
•
★
Material type
S
Line size
005(2)
1 2
•
•
★
010(2)
1-in. (25 mm)
•
•
★
015(2)
11/2-in. (40 mm)
•
•
★
020
2-in. (50 mm)
•
•
★
030
3-in. (80 mm)
•
•
★
040
4-in. (100 mm)
•
•
★
42
/ -in. (15 mm)
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 5. Rosemount 3051SFC Compact Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
060
6-in. (150 mm)
•
•
★
080
8-in. (200 mm)
•
•
★
100(3)(4)
10-in. (250 mm)
•
•
★
120(3)(4)
12-in. (300 mm)
•
•
★
Primary element type
N000
Annubar sensor size 1
•
•
★
N040
0.40 Beta ratio (β)
•
•
★
N050
0.50 Beta ratio (β)
•
•
★
N065(5)
0.65 Beta ratio (β)
•
•
★
Temperature measurement
T(7)
Integral RTD
—
•
★
0(6)
No temperature sensor
•
•
★
R(7)
Remote thermowell and RTD
•
•
Transmitter connection platform
3
Direct mount
•
•
★
7
Remote mount, NPT connections
•
•
★
Differential pressure range
1
0 to 25 inH2O (0 to 62,16 mbar)
•
•
★
2
0 to 250 inH2O (0 to 621,60 mbar)
•
•
★
3
0 to 1000 inH2O (0 to 2,48 bar)
•
•
★
Static pressure range
A(8)
None
•
•
★
D
Absolute (0 to 800 psia [0 to 55,15 bar])
—
•
★
E(9)
Absolute (0 to 3626 psia [0 to 250,00 bar])
—
•
★
J
Gage (–14.2 to 800 psig [–0,98 to 55,15 bar])
—
•
★
K(9)
Gage (–14.2 to 3626 psig [–0,98 to 250,00 bar])
—
•
★
Transmitter output
A
4–20 mA with digital signal based on HART protocol
•
•
★
F(10)(11)
FOUNDATION Fieldbus protocol
•
•
★
X(12)(13)
Wireless
•
—
★
Transmitter housing style
00
None (customer-supplied electrical connection)
1A
Plantweb housing
1B
Plantweb housing
Emerson.com/Rosemount
Material
Conduit
entry size
N/A
•
—
★
Aluminum
1 2
/ –14 NPT
•
•
★
Aluminum
M20 ⫻ 1.5
•
•
★
N/A
43
Rosemount 3051S Series
October 2017
Table 5. Rosemount 3051SFC Compact Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
1J
Plantweb housing
SST
1K
Plantweb housing
SST
2A
Junction Box housing
2B
1 2
/ –14 NPT
•
•
★
M20 ⫻ 1.5
•
•
★
Aluminum
1 2
/ –14 NPT
•
—
★
Junction Box housing
Aluminum
M20 ⫻ 1.5
•
—
★
2E
Junction Box housing with output for remote display and
interface
Aluminum
1 2
/ –14 NPT
•
—
★
2F
Junction Box housing with output for remote display and
interface
Aluminum
M20 ⫻ 1.5
•
—
★
2J
Junction Box housing
SST
1 2
/ –14 NPT
•
—
★
2M
Junction Box housing with output for remote display and
interface
SST
1 2
/ –14 NPT
•
—
★
5A(14)
Wireless Plantweb housing
Aluminum
1 2
/ –14 NPT
•
•
★
5J(14)
Wireless Plantweb housing
SST
1 2
/ –14 NPT
•
•
★
7J(12)(15)
Quick Connect (A size mini, 4-pin male termination)
N/A
N/A
•
—
★
1C
Plantweb housing
Aluminum
G1/2
•
•
1L
Plantweb housing
SST
G/
•
•
2C
Junction Box housing
Aluminum
1 2
G/
•
—
2G
Junction Box housing with output for remote display and
interface
Aluminum
G1/2
•
—
1 2
Performance class(16)
Measurement types 1, 2, 5, and 6
3(17)
Ultra for flow: 0.75% flow rate accuracy, 14:1 flow turndown, 15-yr stability,
15-yr limited warranty
•
•
★
5
Classic MV: 1.10% flow rate accuracy, 8:1 flow turndown, 15-yr stability
—
•
★
Measurement types 3, 4, 7, and D
1
Ultra: 0.90% flow rate accuracy, 8:1 flow turndown, 15-yr stability, 15-yr limited warranty
•
—
★
2
Classic: 1.40% flow rate accuracy, 8:1 flow turndown, 15-yr stability
•
—
★
3(17)
Ultra for flow: 0.75% flow rate accuracy, 14:1 flow turndown, 15-yr stability,
15-yr limited warranty
•
•
★
•
•
★
•
•
★
Wireless options (requires option code X and wireless Plantweb housing)
Update rate, operating frequency, and protocol
WA
User configurable update rate
Operating frequency and protocol
3
44
2.4 GHz DSSS, IEC 62591 (WirelessHART)
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 5. Rosemount 3051SFC Compact Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Omni-directional wireless antenna
WK
External antenna
•
•
★
WM
Extended range, external antenna
•
•
★
WN
High-gain, remote antenna
•
•
•
•
★
•
—
★
SmartPower(18)
1
Adapter for Black Power Module (I.S. Power Module sold separately)
Other options (include with selected model number)
HART Revision configuration (requires HART Protocol output code A)(19)
HR7
Configured for HART Revision 7
Extended product warranty
WR3
3-year limited warranty
•
•
★
WR5
5-year limited warranty
•
•
★
Installation accessories
A
ANSI alignment ring (Class 150)
(only required for 10-in. [250 mm] and 12-in. [300mm] line sizes)
•
•
★
C
ANSI alignment ring (Class 300)
(only required for 10-in. [250 mm] and 12-in. [300mm] line sizes)
•
•
★
D
ANSI alignment ring (Class 600)
(only required for 10-in. [250 mm] and 12-in. [300mm] line sizes)
•
•
★
G
DIN alignment ring (PN 16)
•
•
★
H
DIN alignment ring (PN 40)
•
•
★
J
DIN alignment ring (PN 100)
•
•
★
B
JIS alignment ring (10K)
•
•
R
JIS alignment ring (20K)
•
•
S
JIS alignment ring (40K)
•
•
•
•
•
•
Remote adapters
E
Flange adapters 316 SST (1/2-in. NPT)
★
High temperature applications
T
Graphite valve packing (Tmax = 850 °F)
Flow calibration
WC(20)
Flow calibration, 3 Pt, conditioning option C (all pipe schedules)
•
•
WD(21)(22)
Flow calibration, 10 Pt, conditioning option C (all schedules),
Annubar option A (schedule 40)
•
•
Emerson.com/Rosemount
45
Rosemount 3051S Series
October 2017
Table 5. Rosemount 3051SFC Compact Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Pressure testing
P1
Hydrostatic testing with certificate
•
•
Special cleaning(23)
P2
Cleaning for special processes
•
•
PA
Cleaning per ASTM G93 level D (section 11.4)
•
•
Special inspection
QC1
Visual and dimensional inspection with certificate
•
•
★
QC7
Inspection and performance certificate
•
•
★
Transmitter calibration certification
Q4
Calibration data certificate for transmitter
•
•
★
QP
Calibration certificate and tamper evident seal
•
•
★
Quality certification for safety(24)
QS
Prior-use certificate of FMEDA data
•
—
★
QT(29)
Safety Certified to IEC 61508 with certificate of FMEDA data
•
—
★
•
•
★
Material traceability certifications
Q8
Material traceability certification per EN 10204:2004 3.1
Code conformance
J2
ANSI/ASME B31.1
•
•
J3
ANSI/ASME B31.3
•
•
J4
ANSI/ASME B31.8
•
•
•
•
•
•
Material conformance(25)
J5
NACE MR-0175/ISO 15156
Country certification
J1
Canadian registration
Product certifications
E1
ATEX Flameproof
•
•
★
I1
ATEX Intrinsic Safety
•
•
★
IA(26)
ATEX FISCO Intrinsic Safety
•
•
★
N1
ATEX Type n
•
•
★
ND
ATEX Dust
•
•
★
K1
ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E1, I1, N1, and ND)
•
•
★
E4
TIIS Flameproof
•
•
★
E5
FM Explosion-proof, Dust Ignition-proof
•
•
★
46
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 5. Rosemount 3051SFC Compact Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
I5
FM Intrinsically Safe; Nonincendive
•
•
★
IE(26)
FM FISCO Intrinsic Safety
•
•
★
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
(combination of E5 and I5)
•
•
★
E6(27)
CSA Explosion-proof, Dust Ignition-proof, Division 2
•
•
★
IF(26)
CSA FISCO Intrinsic Safety
•
•
★
I6
CSA Intrinsically Safe
•
•
★
K6(27)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
(combination of E6 and I6)
•
•
★
E7
IECEx Flameproof, Dust Ignition-proof
•
•
★
IG(26)
IECEx FISCO Intrinsic Safety
•
•
★
I7
IECEx Intrinsic Safety
•
•
★
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n
(combination of E7, I7, and N7)
•
•
★
E3
China Flameproof
•
•
★
I3
China Intrinsic Safety
•
•
★
EM
Technical Regulations Customs Union (EAC) Flameproof
•
•
★
IM
Technical Regulations Customs Union (EAC) Intrinsic Safety
•
•
★
KM
Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety
•
•
★
KG(26)
ATEX, FM, CSA, and IECEx FISCO Intrinsic Safety (combination of IA, IE, IF, and IG)
•
•
★
KA(27)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2 (combination of E1, I1, E6, and I6)
•
•
★
KB(27)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
(combination of E5, E6, I5, and I6)
•
•
★
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2
(combination of E5, E1, I5, and I1)
•
•
★
KD(27)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe
(combination of E5, E6, E1, I5, I6, and I1)
•
•
★
Shipboard approvals(28)
SBS
American Bureau of Shipping
•
•
★
SBV
Bureau Veritas (BV) Type Approval
•
•
★
SDN
Det Norske Veritas (DNV) Type Approval
•
•
★
SLL
Lloyds Register (LR) Type Approval
•
•
★
Sensor fill fluid and O-ring options
L1
Inert sensor fill fluid
•
•
★
L2
Graphite-filled (PTFE) O-ring
•
•
★
LA
Inert sensor fill fluid and graphite-filled (PTFE) O-ring
•
•
★
Emerson.com/Rosemount
47
Rosemount 3051S Series
October 2017
Table 5. Rosemount 3051SFC Compact Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Digital display(29)
M5
Plantweb LCD display
•
•
★
M7(30)(31)(32)
Remote mount LCD display and interface, Plantweb housing, no cable, SST bracket
•
—
★
M8(30)(31)
Remote mount LCD display and interface, Plantweb housing, 50 ft (15m) cable,
SST bracket
•
—
★
M9(30)(31)
Remote mount LCD display and interface, Plantweb housing, 100 ft (31m) cable,
SST bracket
•
—
★
•
•
★
Transient protection(33)
T1
Transient terminal block
Manifold for remote mount option
F2
3-valve manifold, SST
•
•
★
F6
5-valve manifold, SST
•
•
★
•
•
★
Plantweb control functionality
A01
FOUNDATION Fieldbus advanced control function block suite
Plantweb diagnostic functionality
D01
FOUNDATION Fieldbus diagnostics suite
•
—
★
DA2(34)
Advanced HART diagnostic suite
•
—
★
•
—
★
•
•
★
Plantweb enhanced measurement functionality
H01
FOUNDATION Fieldbus fully compensated mass flow block
Cold temperature(35)(36)(37)
BRR
–58 °F (–50 °C) cold temperature start-up
Alarm limit(35)
C4
NAMUR alarm and saturation levels, high alarm
•
•
★
C5
NAMUR alarm and saturation levels, low alarm
•
•
★
C6
Custom alarm and saturation levels, high alarm
•
•
★
C7
Custom alarm and saturation levels, low alarm
•
•
★
C8
Low alarm (standard Rosemount alarm and saturation levels)
•
•
★
Hardware adjustments and ground screw
D1(30)(35)(37)
Hardware adjustments (zero, span, alarm, security)
•
—
★
D4(38)
External ground screw assembly
•
•
★
•
—
★
•
•
★
DA(30)(35)(37)(38) Hardware adjustments (zero, span, alarm, security) and external ground screw assembly
Conduit plug
DO
48
316 SST conduit plug
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 5. Rosemount 3051SFC Compact Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Conduit electrical connector(39)
ZE
M12, 4-pin, male connector (eurofast)
•
•
★
ZM
A size mini, 4-pin, male connector (minifast)
•
•
★
Typical model number:
1.
3051SFC 1 C S 060 N 065 T 3 2 J A 1A 3
For option code A: 4–20 mA HART only.
2.
Available with primary element technology P only.
3.
For the 10-in. (250 mm) and 12-in. (300 mm) line sizes, the alignment ring must be ordered (Installation Accessories).
4.
10-in. (250 mm) and 12-in. (300 mm) line sizes not available with primary element technology code A.
5.
For 2-in. (50 mm) line size the beta ratio is 0.6 for primary element technology code C.
6.
Required for Measurement Type codes 2, 4, 6, and D.
7.
Only available with Measurement Type codes 1, 3, 5, 7.
8.
Required for Measurement Type codes 3, 4, 7, and D.
9.
For Measurement Type codes 1, 2, 5, and 6 with DP range 1, absolute limits are 0.5 to 2000 psi (0,03 to 137,9 bar) and gage limits are -14.2 to 2000 psig
(-0,98 to 137,9 bar).
10.
Requires Plantweb housing.
11.
Transmitter output code F is only available with Measurement type code 1, 2, 5, 6, and D.
12.
Only intrinsically safe approval codes apply.
13.
Only available with Measurement Types D and 6.
14.
Only available with output code X.
15.
Available with output code A only.
16.
For detailed specifications see “Specifications” on page 104.
17.
Only available with differential pressure ranges 2 and 3, and silicone fill fluid.
18.
Long-life Power Module must be shipped separately, order Power Module 701PBKKF.
19.
Option HR7 configures the HART output to HART Revision 7. This option requires the selection of the Advanced Diagnostics (DA2) option. The device with this option
can be field configured to HART Revision 5 or 7 if desired.
20.
Available with primary element technology code C only.
21.
Available with primary element technology codes C or A only.
22.
For Annubar Option A, consult factory for pipe schedules other than Sch. 40.
23.
Available with primary element technology C or P only.
24.
Not available with output codes F or X.
25.
Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental limits apply
to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
26.
FISCO is only available with Transmitter output code F.
27.
Not available with M20 or G1/2 conduit entry size.
28.
Not available with transmitter output code F with Measurement Types 1, 2, 5, or 6.
29.
Not available with housing code 7J.
30.
Not available with output code X. Only available with Measurement Type D.
31.
Not available with output code F, option code DA2, or option code QT.
32.
See the Rosemount 3051S Reference Manual for cable requirements. Contact an Emerson representative for additional information.
33.
Not available with Housing code 00, 5A, 5J, or 7J. External ground screw assembly (option code D4) is included with the T1 option. The T1 option is not needed with
FISCO Product Certifications.
34.
Includes Hardware Adjustments (option code D1) as standard. Not available with output code X or F. Only available with Measurement Type D.
35.
Not available with Output Protocol code F.
36.
-58 °F (50 °C) for Measurement Type 1-7.
37.
Not available with housing codes 2E, 2F, 2G, 2M, 5A, 5J, or 7J.
38.
This assembly is included with options EP, KP, E1, N1, K1, ND, E4, E7, K7, E3, KA, KC, KD, IA, T1, EM, and KM.
39.
Not available with Housing code 5A, 5J, or 7J. Available with Intrinsically Safe approvals only. For FM Intrinsically Safe; Nonincendive (option code I5) or FM FISCO
Intrinsically Safe (option code IE), install in accordance with Rosemount drawing 03151-1009.
Emerson.com/Rosemount
49
Rosemount 3051S Series
October 2017
Rosemount 3051SFP Integral Orifice Flowmeter

Precision honed pipe section for increased accuracy in small line sizes

Self-centering plate design prevents alignment errors that magnify measurement inaccuracies in small line
sizes
Specification and selection of product materials, options, or components must be made by the purchaser of the
equipment. See page 124 for more information on material selection.
Table 6. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
• = Available
— = Unavailable
Model
3051SFP
Measurement
type
Product description
Integral orifice flowmeter
D
1-7
•
•
Measurement type
1
Fully compensated mass and energy(1) flow calculations – differential and static pressures
with temperature
—
•
★
2
Compensated flow calculations – differential and static pressures
—
•
★
3
Compensated flow calculations – differential pressure and temperature
—
•
★
4
Compensated flow calculations – differential pressure
—
•
★
D
Differential pressure
•
—
★
5
Process variables only (no flow calculations) – differential and static pressures with
temperature
—
•
★
6
Process variables only (no flow calculations) – differential and static pressures
—
•
★
7
Process variables only (no flow calculations) – differential pressure and temperature
—
•
★
•
•
★
Body material
S
316 SST
Line size
005
1 2
•
•
★
010
1-in. (25 mm)
•
•
★
015
1 / -in. (40 mm)
•
•
★
/ -in. (15 mm)
1 2
Process connection
T1
NPT female body (not available with thermowell and RTD)
•
•
★
S1(2)
Socket weld body (not available with thermowell and RTD)
•
•
★
P1
Pipe ends: NPT threaded
•
•
★
P2
Pipe ends: beveled
•
•
★
D1
Pipe ends: flanged, DIN PN16, slip-on
•
•
★
D2
Pipe ends: flanged, DIN PN40, slip-on
•
•
★
50
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 6. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
D3
Pipe ends: flanged, DIN PN100, slip-on
•
•
★
W1
Pipe ends: flanged, ANSI Class 150, weld-neck
•
•
★
W3
Pipe ends: flanged, ANSI Class 300, weld-neck
•
•
★
W6
Pipe ends: flanged, ANSI Class 600, weld-neck
•
•
★
A1
Pipe ends: flanged, RF, ANSI Class 150, slip-on
•
•
A3
Pipe ends: flanged, RF, ANSI Class 300, slip-on
•
•
A6
Pipe ends: flanged, RF, ANSI Class 600, slip-on
•
•
R1
Pipe ends: flanged, RTJ, ANSI Class 150, slip-on
•
•
R3
Pipe ends: flanged, RTJ, ANSI Class 300, slip-on
•
•
R6
Pipe ends: flanged, RTJ, ANSI Class 600, slip-on
•
•
P9
Special process connection
•
•
Orifice plate material
S
316 SST
•
•
H
Alloy C-276
•
•
M
Alloy 400
•
•
★
Bore size option
0066
0.066-in. (1,68 mm) for 1/2-in. pipe
•
•
★
0109
0.109-in. (2,77 mm) for 1/2-in. pipe
•
•
★
0160
0.160-in. (4,06 mm) for 1/2-in. pipe
•
•
★
0196
0.196-in. (4,98 mm) for / -in. pipe
•
•
★
0260
0.260-in. (6,60 mm) for / -in. pipe
•
•
★
0340
0.340-in. (8,64 mm) for 1/2-in. pipe
•
•
★
0150
0.150-in. (3,81 mm) for 1-in. pipe
•
•
★
0250
0.250-in. (6,35 mm) for 1-in. pipe
•
•
★
0345
0.345-in. (8,76 mm) for 1-in. pipe
•
•
★
0500
0.500-in. (12,70 mm) for 1-in. pipe
•
•
★
0630
0.630-in. (16,00 mm) for 1-in. pipe
•
•
★
0800
0.800-in. (20,32 mm) for 1-in. pipe
•
•
★
0295
0.295-in. (7,49 mm) for 1 / -in. pipe
•
•
★
0376
0.376-in. (9,55 mm) for 11/2-in. pipe
•
•
★
0512
0.512-in. (13,00 mm) for 11/2-in. pipe
•
•
★
0748
0.748-in. (19,00 mm) for 1 / -in. pipe
•
•
★
1022
1.022-in. (25,96 mm) for 1 / -in. pipe
•
•
★
1184
1.184-in. (30,07 mm) for 11/2-in. pipe
•
•
★
0010
0.010-in. (0,25 mm) for 1/2-in. pipe
•
•
1 2
1 2
1 2
1 2
1 2
Emerson.com/Rosemount
51
Rosemount 3051S Series
October 2017
Table 6. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
0014
0.014-in. (0,36 mm) for 1/2-in. pipe
•
•
0020
0.020-in. (0,51 mm) for 1/2-in. pipe
•
•
0034
0.034-in. (0,86 mm) for / -in. pipe
•
•
1 2
Transmitter connection platform
D3
Direct mount, 3-valve manifold, SST
•
•
★
D5
Direct mount, 5-valve manifold, SST
•
•
★
R3
Remote mount, 3-valve manifold, SST
•
•
★
R5
Remote mount, 5-valve manifold, SST
•
•
★
D4
Direct mount, 3-valve manifold, Alloy C-276
•
•
D6
Direct mount, 5-valve manifold, Alloy C-276
•
•
D7
Direct mount, high temperature, 5-valve manifold, SST
•
•
R4
Remote mount, 3-valve manifold, Alloy C-276
•
•
R6
Remote mount, 5-valve manifold, Alloy C-276
•
•
Differential pressure range
1
0 to 25 inH2O (0 to 62,16 mbar)
•
•
★
2
0 to 250 inH2O (0 to 621,60 mbar)
•
•
★
3
0 to 1000 inH2O (0 to 2,48 bar)
•
•
★
Static pressure range
A(3)
None
•
•
★
D
Absolute (0 to 800 psia [0 to 55,15 bar])
—
•
★
E(4)
Absolute (0 to 3626 psia [0 to 250,00 bar])
—
•
★
J
Gage (–14.2 to 800 psig [–0,98 to 55,15 bar])
—
•
★
K(4)
Gage (–14.2 to 3626 psig [–0,98 to 250,00 bar])
—
•
★
Transmitter output
A
4–20 mA with digital signal based on HART protocol
•
•
★
F(5)
FOUNDATION Fieldbus (requires Plantweb housing)
•
•
★
X(6)(7)
Wireless (requires wireless options and wireless Plantweb housing)
•
•
★
Transmitter housing style
Material
Conduit entry size
N/A
•
—
★
Aluminum
1 2
/ –14 NPT
•
•
★
Plantweb housing
Aluminum
M20 ⫻ 1.5
•
•
★
1J
Plantweb housing
SST
1 2
/ –14 NPT
•
•
★
1K
Plantweb housing
SST
2A
Junction box housing
2B
Junction box housing
00
None (customer-supplied electrical connection)
1A
Plantweb housing
1B
52
N/A
M20 ⫻ 1.5
•
•
★
Aluminum
1 2
/ –14 NPT
•
—
★
Aluminum
M20 ⫻ 1.5
•
—
★
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 6. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
2E
Junction box housing with output for remote
display and interface
Aluminum
1 2
/ –14 NPT
•
—
★
2F
Junction box housing with output for remote
display and interface
Aluminum
M20 ⫻ 1.5
•
—
★
2J
Junction box housing
SST
1 2
/ –14 NPT
•
—
★
2M
Junction box housing with output for remote
display and interface
SST
1 2
/ –14 NPT
•
—
★
5A(8)
Wireless Plantweb housing
Aluminum
1 2
/ –14 NPT
•
•
★
5J(8)
Wireless Plantweb housing
SST
1 2
/ –14 NPT
•
•
★
7J(6)(9)
Quick Connect (A size mini, 4-pin male
termination)
N/A
N/A
•
—
★
1C
Plantweb housing
Aluminum
G1/2
•
•
1L
Plantweb housing
SST
G1/2
•
•
2C
Junction Box housing
Aluminum
G1/2
•
—
2G
Junction Box housing with output for remote
display and interface
Aluminum
G1/2
•
—
Performance class(10)
Measurement types 1, 2, 5, and 6
3(11)
Ultra for Flow: 0.95% flow rate accuracy, 14:1 flow turndown, 15-year stability,
15-year limited warranty
•
•
★
5
Classic MV: 1.25% flow rate accuracy, 8:1 flow turndown, 15-year stability
—
•
★
Measurement types 3, 4, 7, and D
1
Ultra: 1.05% flow rate accuracy, 8:1 flow turndown, 15-year stability,
15-year limited warranty
•
•
★
2
Classic: 1.50% flow rate accuracy, 8:1 flow turndown, 15-year stability
•
•
★
3(11)
Ultra for Flow: 0.95% flow rate accuracy, 14:1 flow turndown, 15-year stability,
15-year limited warranty
•
•
★
•
•
★
•
•
★
Wireless options (requires option code X and wireless Plantweb housing)
Update rate, operating frequency and protocol
WA
User configurable update rate
Operating frequency and protocol
3
2.4 GHz DSSS, IEC 62591 (WirelessHART)
Omni-directional wireless antenna
WK
External antenna
•
•
★
WM
Extended range, external antenna
•
•
★
WN
High-gain, remote antenna
•
•
Emerson.com/Rosemount
53
Rosemount 3051S Series
October 2017
Table 6. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
SmartPower(12)
1
Adapter for Black Power Module (I.S. Power Module sold separately)
•
•
★
•
—
★
Other options (include with selected model number)
HART Revision configuration (requires HART Protocol output code A)(13)
HR7
Configured for HART Revision 7
Extended product warranty
WR3
3-year limited warranty
•
•
★
WR5
5-year limited warranty
•
•
★
•
•
•
•
★
•
•
★
•
•
Transmitter/body bolt material(14)
G
High temperature option (850 °F [454 °C])
Temperature sensor(15)
T
Thermowell and RTD
Optional connection
G1
DIN 19213 transmitter connection
Pressure testing
P1(16)
Hydrostatic testing with certificate
Special cleaning
P2
Cleaning for special services
•
•
PA
Cleaning per ASTM G93 level D (section 11.4)
•
•
•
•
•
•
Material testing
V1
Dye penetrant exam
Material examination
V2
Radiographic examination (available only with process connection code W1, W3, and W6)
Flow calibration(17)
WD
Discharge coefficient verification
•
•
WZ
Special calibration
•
•
Special inspection
QC1
Visual and dimensional inspection with certificate
•
•
★
QC7
Inspection and performance certificate
•
•
★
•
•
★
Material traceability certification
Q8
54
Material certification per EN 10204:2004 3.1
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 6. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Code conformance(18)
J2
ANSI/ASME B31.1
•
•
J3
ANSI/ASME B31.3
•
•
J4
ANSI/ASME B31.8
•
•
•
•
Materials conformance(19)
J5
NACE MR-0175/ISO 15156
Country certification
J6
European pressure directive (PED)
•
•
J1
Canadian registration
•
•
★
Transmitter calibration certification
Q4
Calibration data certificate for transmitter
•
•
★
QP
Calibration certificate and tamper evident seal
•
•
★
Quality certification for safety(20)
QS
Prior-use certificate of FMEDA data
•
—
★
QT(21)
Safety-certified to IEC 61508 with certificate of FMEDA data
•
—
★
Product certifications
E1
ATEX Flameproof
•
•
★
I1
ATEX Intrinsic Safety
•
•
★
IA(22)
ATEX FISCO Intrinsic Safety
•
•
★
N1
ATEX Type n
•
•
★
ND
ATEX Dust
•
•
★
K1
ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E1, I1, N1, and ND)
•
•
★
E4
TIIS Flameproof
•
•
★
E5
FM Explosion-proof, Dust Ignition-proof
•
•
★
I5
FM Intrinsically Safe; Nonincendive
•
•
★
IE(22)
FM FISCO Intrinsic Safety
•
•
★
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
(combination of E5 and I5)
•
•
★
E6(23)
CSA Explosion-proof, Dust Ignition-proof, Division 2
•
•
★
I6
CSA Intrinsically Safe
•
•
★
IF(22)
CSA FISCO Intrinsic Safety
•
•
★
K6(23)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
(combination of E6 and I6)
•
•
★
E7
IECEx Flameproof, Dust Ignition-proof
•
•
★
IG(22)
IECEx FISCO Intrinsic Safety
•
•
★
Emerson.com/Rosemount
55
Rosemount 3051S Series
October 2017
Table 6. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
I7
IECEx Intrinsic Safety
•
•
★
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n
(combination of E7, I7, and N7)
•
•
★
E3
China Flameproof
•
•
★
I3
China Intrinsic Safety
•
•
★
EM
Technical Regulations Customs Union (EAC) Flameproof
•
•
★
IM
Technical Regulations Customs Union (EAC) Intrinsic Safety
•
•
★
KM
Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety
•
•
★
KG(22)
ATEX, FM, CSA, and IECEx FISCO Intrinsic Safety (combination of IA, IE, IF, and IG)
•
•
★
KA(23)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2 (combination of E1, I1, E6, and I6)
•
•
★
KB(23)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
(combination of E5, E6, I5, and I6)
•
•
★
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2
(combination of E5, E1, I5, and I1)
•
•
★
KD(23)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe
(combination of E5, I5, E6, I6, E1, and I1)
•
•
★
Shipboard approvals(24)
SBS
American Bureau of Shipping
•
•
★
SBV
Bureau Veritas (BV) Type Approval
•
•
★
SDN
Det Norske Veritas (DNV) Type Approval
•
•
★
SLL
Lloyds Register (LR) Type Approval
•
•
★
Sensor fill fluid and O-ring options
L1
Inert sensor fill fluid
•
•
★
L2
Graphite-filled (PTFE) O-ring
•
•
★
LA
Inert sensor fill fluid and graphite-filled (PTFE) O-ring
•
•
★
Digital display(21)
M5
Plantweb LCD display (requires Plantweb housing)
•
•
★
M7(25)(26)
Remote mount LCD display and interface, Plantweb housing, no cable, SST bracket
•
—
★
M8(26)
Remote mount LCD display and interface, Plantweb housing, 50 ft. (15 m) cable,
SST bracket
•
—
★
M9(26)
Remote mount LCD display and interface, Plantweb housing, 100 ft. (31 m) cable,
SST bracket
•
—
★
•
•
★
•
•
★
Transient protection(27)
T1
Transient terminal block
Plantweb control functionality
A01
56
FOUNDATION Fieldbus advanced control function block suite
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 6. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Plantweb diagnostic functionality
D01
FOUNDATION Fieldbus diagnostics suite
•
—
★
DA2(28)
Advanced HART diagnostics suite
•
—
★
•
—
★
•
•
★
Plantweb enhanced measurement functionality
H01
FOUNDATION Fieldbus fully compensated mass flow block
Cold temperature(29)(30)
BRR
-58 °F (-50 °C) cold temperature start-up
Alarm limit(29)
C4
NAMUR alarm and saturation levels, high alarm
•
•
★
C5
NAMUR alarm and saturation levels, low alarm
•
•
★
C6
Custom alarm and saturation levels, high alarm
•
•
★
C7
Custom alarm and saturation levels, low alarm
•
•
★
C8
Low alarm (standard Rosemount alarm and saturation levels)
•
•
★
Hardware adjustments and ground screw
D1(21) (31)(32)
Hardware adjustments (zero, span, alarm, security)
•
—
★
D4(33)
External ground screw assembly
•
•
★
DA(21)(31)(32)
Hardware adjustments (zero, span, alarm, security) and external ground screw assembly
•
—
★
•
•
★
Conduit plug
DO
316 SST conduit plug
Conduit electrical connector(34)
GE
M12, 4-pin, male connector (eurofast)
•
•
GM
A size mini, 4-pin, male connector (minifast)
•
•
Typical model number: 3051SFP
1.
1
S
010
W3
S
0150
D3
1
J
A
1A
3
M5
For option code A: 4–20 mA HART only.
2.
To improve pipe perpendicularity for gasket sealing, socket diameter is smaller than standard pipe O.D.
3.
Required for measurement type codes 3, 4, 7, and D.
4.
For Measurement Type codes 1, 2, 5, and 6 with DP range 1, absolute limits are 0.5 to 2000 psi (0,03 to 137,9 bar) and gage limits are –14.2 to 2000 psig (–0,98 to
137,9 bar).
5.
Transmitter output code F is only available with Measurement type code 1, 2, 5, 6, and D.
6.
Only intrinsically safe approval codes apply.
7.
Only available with measurement types D and 6.
8.
Only available with output code X.
9.
Only available with output code A.
10.
For detailed specifications see “Specifications” on page 104.
11.
Only available with differential pressure ranges 2 and 3, and silicone fill fluid.
12.
Long-life Power Module must be shipped separately, order Power Module 701PBKKF.
13.
Option HR7 configures the HART output to HART Revision 7. This option requires the selection of the Advanced Diagnostics (DA2) option. The device with this option
can be field configured to HART Revision 5 or 7 if desired.
Emerson.com/Rosemount
57
Rosemount 3051S Series
14.
Not available with 11/2-in. (38 mm) line size.
15.
Thermowell material is the same as the body material.
October 2017
16.
Does not apply to process connection codes T1 and S1.
17.
Not available for bore sizes 0010, 0014, 0020, or 0034.
18.
Not available with DIN process connection codes D1, D2, or D3.
19.
Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental limits apply
to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
20.
Not available with output codes F or X.
21.
Not available with housing code 7J.
22.
FISCO is only available with Transmitter output code F.
23.
Not available with M20 or G 1/2 conduit entry size.
24.
Not available with transmitter output code F with Measurement Types 1, 2, 5, or 6.
25.
See the Rosemount 3051S Reference Manual for cable requirements. Contact an Emerson representative for additional information.
26.
Not available with output code F, option code DA2, or option code QT.
27.
Not available with housing code 5A, 5J, or 7J. The T1 option is not needed with FISCO Product Certifications.
28.
Includes hardware adjustments (option code D1) as standard. Not available with output code X or F. Only available with measurement type D.
29.
Not available with output code F.
30.
-58 °F (50 °C) for Measurement Type 1-7.
31.
Not available with output code X. Only available with measurement type D.
32.
Not available with housing codes 2E, 2F, 2G, 2M, 5A, 5J, or 7J.
33.
This assembly is included with options EP, KP, E1, N1, K1, ND, E4, E7, K7, E3, KA, KC, KD, IA, T1, EM, and KM.
34.
Not available with Housing code 5A, 5J, or 7J. Available with Intrinsically Safe approvals only. For FM Intrinsically Safe; Nonincendive (option code I5) or
FM FISCO Intrinsically Safe (option code IE), install in accordance with Rosemount drawing 03151-1009.
58
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Rosemount 3051S Electronic Remote Sensor (ERS)
System
The Rosemount 3051S ERS System is a flexible, 2-wire 4-20 mA HART
architecture that calculates differential pressure (DP) electronically using two
pressure sensors that are linked together with a non-proprietary electrical wire.
Ideal applications for the Rosemount 3051S ERS System include tall vessels and
distillation columns that have traditionally required long lengths of capillary or
impulse piping. When used in these types of applications, the Rosemount
3051S ERS System can deliver:



1

Rosemount
3051SAM
Secondary
More accurate and repeatable DP measurements
Faster time response
Simplified installations
Reduced maintenance
How to order
1. Choose two Rosemount 3051S ERS Transmitter models. These may be any
combination of Rosemount 3051SAM and Rosemount 3051SAL models.
Coplanar
In-line
2. Decide which model will be the ERS Primary (4–20 mA loop termination and
optional LCD display) and which will be the ERS Secondary. This will be
specified by the “Configuration Type” code in each model number.
2
Rosemount
3051SAL
3. Specify two full model numbers per the desired configuration.
Primary
Coplanar
3
In-line
Additional information
Specifications: page 104
Certifications: page 129
Dimensional drawings: page 145
3051SAL1PG4AA1A1020DFF71DA00M5
3051SAM1ST2A2E11A2A
Rosemount 3051SAM Transmitter for ERS Applications

Coplanar and in-line sensor module platforms

Variety of process connections including threaded NPT, flanges, manifolds, and Rosemount 1199 Remote
Seals

Available with 15-year stability and 15-year limited warranty
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 124 for more information on material selection.
Table 7. Rosemount 3051SAM Transmitter for ERS Applications Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Model
Transmitter type
3051SAM
Scalable ERS Measurement Transmitter
Performance class
1
Ultra: 0.025% span accuracy, 200:1 rangedown, 15-year stability, 15-year limited warranty
★
2
Classic: 0.035% span accuracy, 150:1 rangedown, 15-year stability
★
4
Enhanced ERS System performance, 15-year stability, 15-year limited warranty
★
Emerson.com/Rosemount
59
Rosemount 3051S Series
October 2017
Table 7. Rosemount 3051SAM Transmitter for ERS Applications Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Configuration type
P
Electronic remote sensor - primary
★
S
Electronic remote sensor - secondary
★
Pressure module type
Pressure sensor type
G
Coplanar
Gage
★
T
In-Line
Gage
★
E
In-Line
Absolute
★
A
Coplanar
Absolute
Pressure range(1)
Coplanar gage
In-line gage
In-line absolute
Coplanar absolute
1A
N/A
–14.7 to 30 psig
(–1,0 to 2,06 bar)
0 to 30 psia
(0 to 2,06 bar)
0 to 30 psia
(0 to 2,06 bar)
★
2A
–250 to 250 inH2O
(–623 to 623 mbar)
–14.7 to 150 psig
(–1,0 to 10,34 bar)
0 to 150 psia
(0 to 10,34 bar)
0 to 150 psia
(0 to 10,34 bar)
★
3A
–393 to 1000 inH2O
(–0,98 to 2,49 bar)
–14.7 to 800 psig
(–1,0 to 55,2 bar)
0 to 800 psia
(0 to 55,2 bar)
0 to 800 psia
(0 to 55,2 bar)
★
4A
–14.2 to 300 psig
(–0,98 to 20,7 bar)
–14.7 to 4000 psig
(–1,0 to 275,8 bar)
0 to 4000 psia
(0 to 275,8 bar)
0 to 4000 psia
(0 to 275,8 bar)
★
5A
–14.2 to 2000 psig
(–0,98 to 137,9 bar)
–14.7 to 10000 psig
(–1,0 to 689,5 bar)
0 to 10000 psia
(0 to 689,5 bar)
N/A
★
Isolating diaphragm
2(2)
316L SST
★
3(2)
Alloy C-276
★
4(3)
Alloy 400
5(3)(4)
Tantalum
6(3)
Gold-plated Alloy 400 (includes graphite-filled PTFE O-Ring)
7(3)
Gold-plated 316L SST
Process connection
Coplanar module type
In-Line module type
000
None
N/A
★
A11(5)
Assemble to Rosemount 305 Manifold
Assemble to Rosemount 306 Manifold
★
A12(5)
Assemble to Rosemount 304 or AMF Manifold with SST
Traditional Flange
N/A
★
B11(5)(6)
Assemble to one Rosemount 1199 Remote Diaphragm
Seal with SST transmitter flange
Assemble to One Rosemount 1199 Remote
Diaphragm
★
E11
Coplanar flange (CS), 1/4–18 NPT, 316 SST drain vents
1 2
★
E12
Coplanar flange (SST), 1/4–18 NPT, 316 SST drain vents
N/A
★
60
/ –14 NPT Female
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 7. Rosemount 3051SAM Transmitter for ERS Applications Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
E13(2)
Coplanar flange (Cast C-276), 1/4–18 NPT, Alloy C-276
drain vents
N/A
★
E14
Coplanar flange (Cast Alloy 400), 1/4–18 NPT, Alloy
400/K-500 drain vents
N/A
★
E15(2)
Coplanar flange (SST), 1/4–18 NPT, Alloy C-276 drain vents
N/A
★
E16(2)
Coplanar flange (CS), / –18 NPT, Alloy C-276 drain vents
N/A
★
E21
Coplanar flange (CS), RC / , 316 SST drain vents
N/A
★
E22
Coplanar flange (SST), RC 1/4, 316 SST drain vents
N/A
★
E23(2)
Coplanar flange (Cast C-276), RC 1/4, Alloy C-276 drain
vents
N/A
★
E24
Coplanar flange (Cast Alloy 400), RC 1/4, alloy 400/K-500
drain vents
N/A
★
E25(2)
Coplanar flange (SST), RC 1/4, Alloy C-276 drain vents
N/A
★
E26(2)
Coplanar flange (CS), RC 1/4, Alloy C-276 drain vents
N/A
★
F11
Traditional flange (CS), / –18 NPT, 316 SST drain/vents
Non-threaded instrument flange (I-Flange)
F12
Traditional flange (SST), 1/4–18 NPT, 316 SST drain vents
N/A
★
F13(2)
Traditional flange (Cast C-276), 1/4–18 NPT, Alloy C-276
drain vents
N/A
★
F14
Traditional flange (Cast Alloy 400), 1/4–18 NPT, Alloy
400/K-500 drain vents
N/A
★
F15(2)
Traditional flange (SST), 1/4–18 NPT, Alloy C-276 drain
vents
N/A
★
F22
Traditional flange (SST), RC 1/4, 316 SST drain vents
N/A
★
F23(2)
Traditional flange (Cast C-276), RC / , Alloy C-276 drain
vents
N/A
★
F24
Traditional flange (Cast Alloy 400), RC 1/4, Alloy 400/K500
drain vents
N/A
★
F25(2)
Traditional flange (SST), RC 1/4, Alloy C-276 drain vents
N/A
★
F52
DIN-compliant traditional flange (SST), / –18 NPT, 316
drain vents, 7 to 16-in. bolting
N/A
★
G11
Vertical mount level flange (SST), 2-in. ANSI Class 150, 316
SST drain vents
G 1/2 A DIN 16288 male (range 1–4 only)
★
G12
Vertical mount level flange (SST), 2-in. ANSI Class 300, 316
SST drain vents
N/A
★
G21
Vertical mount level flange (SST), 3-in. ANSI Class 150, 316
SST drain vents
N/A
★
G22
Vertical mount level flange (SST), 3-in. ANSI Class 300, 316
SST drain vents
N/A
★
G31
Vertical mount level flange (SST), DIN-DN 50 PN 40, 316
SST drain vents
N/A
★
G41
Vertical mount level flange (SST), DIN-DN 80 PN 40, 316
SST drain vents
N/A
1 4
1 4
1 4
1 4
1 4
Emerson.com/Rosemount
61
Rosemount 3051S Series
October 2017
Table 7. Rosemount 3051SAM Transmitter for ERS Applications Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
P11
N/A
Level flange (SST), 2-in. ANSI Class 150
★
P12
N/A
Level flange (SST), 2-in. ANSI Class 300
★
P21
N/A
Level flange (SST), 3-in. ANSI Class 150
★
P22
N/A
Level flange (SST), 3-in. ANSI Class 300
★
P31
N/A
Level flange (SST), DIN-DN 50 PN 40
★
P41
N/A
Level flange (SST), DIN-DN 80 PN 40
★
F32
Bottom vent traditional flange (SST), / –18 NPT, 316 SST
drain vents
N/A
F42
Bottom vent traditional flange (SST), RC 1/4, 316 SST drain
vents
N/A
F62
DIN-compliant traditional flange (316 SST), 1/4–18 NPT,
316 drain vents, M10 bolting
N/A
F72
DIN-compliant traditional flange (316 SST), 1/4–18 NPT,
316 drain vents, M12 bolting
N/A
1 4
Transmitter output
A
★
4–20 mA with digital signal based on HART protocol
Housing style
Material
Conduit entry size
Housings for ERS Primary - Configuration Type code P
1A
Plantweb housing
Aluminum
1 2
★
1B
Plantweb housing
Aluminum
M20 ⫻ 1.5 (CM 20)
★
1J
Plantweb housing
SST
1 2
★
1K
Plantweb housing
SST
M20 ⫻ 1.5 (CM 20)
★
2E
Junction box with remote display output
Aluminum
1 2
★
2F
Junction box with remote display output
Aluminum
M20 ⫻ 1.5 (CM 20)
★
2M
Junction box with remote display output
SST
1 2
/ –14 NPT
/ –14 NPT
/ –14 NPT
/ –14 NPT
★
/ –14 NPT
Housings for ERS Secondary - Configuration Type code S
2A
Junction box
Aluminum
1 2
★
2B
Junction box
Aluminum
M20 ⫻ 1.5 (CM 20)
★
2J
Junction box
SST
1 2
/ –14 NPT
★
Housings for ERS Primary - Configuration Type code P
1C
Plantweb housing
Aluminum
G1/2
1L
Plantweb housing
SST
G1/2
2G
Junction box with remote display output
Aluminum
G1/2
Aluminum
G1/2
Housings for ERS Secondary - Configuration Type code S
2C
62
Junction box
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 7. Rosemount 3051SAM Transmitter for ERS Applications Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Options (include with select ed model number)
Electronic remote sensor connection cable
R02
25 ft (7,62 m) of Electronic Remote Sensors cable (gray color)
R05
50 ft. (15,2 m) of Electronic Remote Sensors cable (gray color)
★
R10
100 ft. (30,5 m) of Electronic Remote Sensors cable (gray color)
★
R15
150 ft. (45,72 m) of Electronic Remote Sensors cable (gray color)
★
R20(7)
200 ft. (60,96 m) of Electronic Remote Sensors cable (gray color)
R22(8)
225 ft. (68,58 m) of Electronic Remote Sensors cable (gray color)
R30
300 ft. (91,44 m) of Electronic Remote Sensors cable (gray color)
R40
400 ft. (121,92 m) of Electronic Remote Sensors cable (gray color)
R50
500 ft. (152,4 m) of Electronic Remote Sensors cable (gray color)
H02
25 ft. (7,62 m) of Electronic Remote Sensors cable (blue color)
H05
50 ft. (15,2 m) of Electronic Remote Sensors cable (blue color)
H10
100 ft. (30,5 m) of Electronic Remote Sensors cable (blue color)
H15
150 ft. (45,7 m) of Electronic Remote Sensors cable (blue color)
H20(7)
200 ft. (60,96 m) of Electronic Remote Sensors cable (blue color)
H22(8)
225 ft. (68,58 m) of Electronic Remote Sensors cable (blue color)
J02
25 ft. (7,62 m) of Electronic Remote Sensors armored cable
J05
50 ft. (15,2 m) of Electronic Remote Sensors armored cable
J07
75 ft. (22,8 m) of Electronic Remote Sensors armored cable
J10
100 ft. (30,5 m) of Electronic Remote Sensors armored cable
J12(8)
125 ft. (38,1 m) of Electronic Remote Sensors armored cable
Mounting bracket
B1(3)
Traditional flange bracket, CS, 2-in. pipe
★
B2(3)
Traditional flange bracket, CS, panel
★
B3(3)
Traditional flange flat bracket, CS, 2-in. pipe
★
B4
Bracket, all SST, 2-in. pipe and panel
★
B7(3)
Traditional flange bracket, B1 with SST bolts
★
Mounting bracket(3)
B8
Traditional flange bracket, B2 with SST bolts
★
B9
Traditional flange bracket, B3 with SST bolts
★
BA
Traditional flange bracket, B1, all SST
★
BC
Traditional flange bracket, B3, all SST
★
Emerson.com/Rosemount
63
Rosemount 3051S Series
October 2017
Table 7. Rosemount 3051SAM Transmitter for ERS Applications Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Special configuration (software)
C1(9)
Customer software configuration (Configuration Data Sheet must be completed)
★
C3
Gage pressure calibration on Rosemount 3051SAM_ _A4 only
★
C4(9)
NAMUR alarm and saturation levels, high alarm
★
C5(9)
NAMUR alarm and saturation levels, low alarm
★
C6(9)
Custom alarm and saturation levels, high alarm (requires C1 and Configuration Data Sheet)
★
C7(9)
Custom alarm and saturation levels, low alarm (requires C1 and Configuration Data Sheet)
★
C8(9)
Low alarm (standard Rosemount alarm and saturation levels)
★
Special configuration (hardware)
D2(10)
1 2
★
D4
External ground screw assembly
★
D5(10)
Delete transmitter drain/vent valves (install plugs)
★
D7(10)
Coplanar flange without drain/vent ports
D9(10)
RC 1/2 flange adapters
/ –14 NPT flange adapters
Product certifications
E1
ATEX Flameproof
★
I1
ATEX Intrinsic Safety
★
N1
ATEX Type n
★
K1
ATEX Flameproof and Intrinsically Safe, Type n, Dust
★
ND
ATEX Dust
★
E4
TIIS Flameproof
★
E5
FM Explosion-proof, Dust Ignition-proof
★
I5
FM Intrinsically Safe, Division 2
★
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
E6(11)
CSA Explosion-proof, Dust Ignition-proof, Division 2
★
I6
CSA Intrinsically Safe
★
K6(11)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
E7
IECEx Flameproof
★
I7
IECEx Intrinsic Safety
★
N7
IECEx Type n
★
K7
IECEx Flameproof, Intrinsic Safety, Type n
★
E2
INMETRO Flameproof
★
I2
INMETRO Intrinsically Safe
★
K2
INMETRO Flameproof, Intrinsic Safety, Type n
★
E3
China Flameproof
★
64
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 7. Rosemount 3051SAM Transmitter for ERS Applications Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
I3
China Intrinsic Safety, Dust Ignition-proof
★
KA(11)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2
★
KB(11)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2
★
KD(11)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe
★
Special certifications
Q4
Calibration certificate
★
QP
Calibration certificate and tamper evident seal
★
Q8
Material traceability certification per EN 10204 3.1
★
Q16
Surface finish certification for hygienic remote seals
★
QZ(12)
Remote seal system performance calculation report
★
T1(9)
Transient terminal block
★
L1(13)
Inert sensor fill fluid
★
L2
Graphite-filled PTFE O-ring
★
L4(10)
Austenitic 316 SST bolts
★
L5(2)(10)
ASTM A 193, Grade B7M bolts
★
Special certifications(10)
L6
Alloy K-500 bolts
★
L7(2)
ASTM A 453, Class D, Grade 660 bolts
★
L8
ASTM A 193, Class 2, Grade B8M bolts
★
Display type (ERS Primary Only)(9)
M5
Plantweb LCD display
★
M7
Remote mount LCD display and interface, Plantweb housing, no cable, SST bracket
★
M8
Remote mount LCD display and interface, Plantweb housing, 50 ft. (15,2 m) cable, SST bracket
★
M9
Remote mount LCD display and interface, Plantweb housing, 100 ft. (30,5 m) cable, SST bracket
★
Special procedures
Pressure testing
P1
Hydrostatic testing with certificate
Special cleaning(10)
P2
Cleaning for special services
P3
Cleaning for less than 1 PPM Chlorine/Fluorine
Typical model number: 3051SAM 1 S T 2A 2 E11 A 2A
1.
The pressure range should be specified based on the maximum static pressure, not differential pressure.
2.
Materials of construction comply with metallurgical requirements highlighted within NACE MR 0175/ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR 0103 for sour refining environments.
Emerson.com/Rosemount
65
Rosemount 3051S Series
3.
Not available with pressure sensor/module codes T or E.
4.
Tantalum diaphragm material is only available with Pressure Sensor/Module code G.
5.
“Assemble to” items are specified separately and require a completed model number.
October 2017
6.
Consult an Emerson representative for performance specifications.
7.
Maxium cable distance for SIS installations. See section "6.1 Safety Instrumented Systems (SIS) Certification" of Rosemount 3051S ERS Reference Manual for more
information.
8.
Maxium cable distance for IS (Intrinsically safe) installations. Other options may not be valid at longer distances.
9.
Not available with Configuration Type code S.
10.
Not available with Process Connection code A11.
11.
Not available with M20 or G1/2 conduit entry size.
12.
The QZ report quantifies the performance of the entire ERS System. One report is provided per ERS System. The QZ option is specified on the primary transmitter
(Configuration Type code P).
13.
Silicone fill fluid is standard.
66
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Rosemount 3051SAL Transmitter for ERS Applications

Integrated transmitter and direct mount seal in a single model number

Variety of process connections including flanged, threaded, and hygienic remote seals

Available with 15-year limited warranty
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 124 for more information on material selection.
A Rosemount 3051SAL Scalable ERS Level Transmitter consists of three parts. First, specify the transmitter model codes found on
page 67. Then, specify a direct mount seal found on page 85. Finish the model number by specifying all desired options on page 70.
Direct Mount Seal Model Codes_page 85
ERS Transmitter Model Codes__page 67
ERS Options____page 70
Table 8. Rosemount 3051SAL Transmitter for ERS Applications Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Model
Transmitter type
3051SAL
Scalable level transmitter
Performance class
1
Ultra: 0.065% span accuracy, 100:1 rangedown, 15-year limited warranty
★
2
Classic: 0.065% span accuracy, 150:1 rangedown
★
4
Enhanced ERS System performance, limited 15-year warranty
★
Configuration type
P
Electronic remote sensor - primary
★
S
Electronic remote sensor - secondary
★
Pressure module type
Pressure sensor type
G
Coplanar
Gage
★
T
In-Line
Gage
★
E
In-Line
Absolute
★
A
Coplanar
Absolute
Pressure range(1)
Coplanar gage
In-Line gage
In-Line absolute
Coplanar
absolute
1A
N/A
–14.7 to 30 psig
(–1,0 to 2,06 bar)
0 to 30 psia
(0 to 2,06 bar)
0 to 30 psia
(0 to 2,06 bar)
★
2A
–250 to 250 inH2O
(–623 to 623 mbar)
–14.7 to 150 psig
(–1,0 to 10,34 bar)
0 to 150 psia
(0 to 10,34 bar)
0 to 150 psia
(0 to 10,34 bar)
★
3A
–393 to 1000 inH2O
(–0,98 to 2,49 bar)
–14.7 to 800 psig
(–1,0 to 55,2 bar)
0 to 800 psia
(0 to 55,2 bar)
0 to 800 psia
(0 to 55,2 bar)
★
4A
–14.2 to 300 psig
(–0,98 to 20,7 bar)
–14.7 to 4000 psig
(–1,0 to 275,8 bar)
0 to 4000 psia
(0 to 275,8 bar)
0 to 4000 psia
(0 to 275,8 bar)
★
Emerson.com/Rosemount
67
Rosemount 3051S Series
October 2017
Table 8. Rosemount 3051SAL Transmitter for ERS Applications Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
5A
–14.2 to 2000 psig
(–0,98 to 137,9 bar)
–14.7 to 10000 psig
(–1,0 to 689,5 bar)
0 to 10000 psia
(0 to 689 bar)
N/A
★
Transmitter output
A
★
4–20 mA with digital signal based on HART Protocol
Housing style
Material
Conduit entry size
Housings for ERS Primary - Configuration Type code P
1A
Plantweb housing
Aluminum
1 2
★
1B
Plantweb housing
Aluminum
M20 ⫻ 1.5 (CM 20)
★
1J
Plantweb housing
SST
1 2
★
1K
Plantweb housing
SST
M20 ⫻ 1.5 (CM 20)
★
2E
Junction box with remote display output
Aluminum
1 2
★
2F
Junction box with remote display output
Aluminum
M20 ⫻ 1.5 (CM 20)
★
2M
Junction box with remote display output
SST
1 2
/ –14 NPT
/ –14 NPT
/ –14 NPT
/ –14 NPT
★
/ –14 NPT
Housings for ERS Secondary - Configuration Type code S
2A
Junction box
Aluminum
1 2
★
2B
Junction box
Aluminum
M20 ⫻ 1.5 (CM 20)
★
2J
Junction box
SST
1 2
/ –14 NPT
★
Housings for ERS Primary - Configuration Type code P
1C
Plantweb housing
Aluminum
G1/2
1L
Plantweb housing
SST
G1/2
2G
Junction box with remote display output
Aluminum
G1/2
Housings for ERS Secondary - Configuration Type code S
2C
Junction box
Aluminum
G1/2
Seal system type
1
Direct-mount seal system
★
Direct-mount extension (between transmitter flange and seal)
0
No extension
★
2
2-in. (50 mm) extension
★
4
4-in. (100 mm) extension
★
5
Thermal optimizer
★
Transmitter reference pressure connection
00
None (in-line style sensor)
★
20
316L SST isolator/SST transmitter flange
★
30
Alloy C-276 isolator/SST transmitter flange
★
68
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 8. Rosemount 3051SAL Transmitter for ERS Applications Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Specific
gravity at
77 °F
(25 °C)
Seal fill fluid
Temperature limits(2)
No extension
2-in. (50 mm) 4-in. (100 mm) Thermal
extension
extension
optimizer
A
SYLTHERM™ XLT
0.85
–102 to 293 °F
(–75 to 145 °C)
–102 to 293 °F
(–75 to 145 °C)
–102 to 293 °F
(–75 to 145°C)
–102 to 293 °F
(–75 to 145 °C)
★
C
D.C. Silicone 704
1.07
32 to 401 °F(3)
(0 to 205 °C)
32 to 464 °F(3)
(0 to 240 °C)
32 to 500 °F(3)
(0 to 260 °C)
32 to 599 °F
(0 to 315 °C)
★
D
Silicone 200
0.93
–49 to 401 °F
(–45 to 205 °C)
–49 to 401 °F
(–45 to 205 °C)
–49 to 401 °F
(–45 to 205 °C)
–49 to 401 °F
(–45 to 205 °C)
★
H
Inert (Halocarbon)
1.85
–49 to 320 °F
(–45 to 160 °C)
–49 to 320 °F
(–45 to 160 °C)
–49 to 320 °F
(–45 to 160 °C)
–49 to 320 °F
(–45 to 160 °C)
★
G(4)(5)
Glycerin and Water
1.13
5 to 203 °F
(–15 to 95 °C)
5 to 203 °F
(–15 to 95 °C)
5 to 203 °F
(–15 to 95 °C)
5 to 203 °F
(–15 to 95 °C)
★
N(4)
Neobee® M-20
0.92
5 to 401 °F(3)
(–15 to 205 °C)
5 to 437 °F
(–15 to 225 °C)
5 to 437 °F
(–15 to 225 °C)
5 to 437 °F
(–15 to 225 °C)
★
P(4)(5)
Propylene Glycol and Water
1.02
5 to 203 °F
(–15 to 95 °C)
5 to 203 °F
(–15 to 95 °C)
5 to 203 °F
(–15 to 95 °C)
5 to 203 °F
(–15 to 95 °C)
★
Continue specifying a completed model number by choosing a remote seal type below:
page 85
FF Flush Flanged Seal
Process connections:
2-in./DN 50/50A
3-in./DN 80/80A
4-in./ DN 100/100A
page 88
EF Extended Flanged Seal
Process connections:
3-in./DN 80/80A
4-in./DN 100/100A
page 90
RF Remote Flanged Seal
Process connections:
1-in./DN 25/25A
11/2-in./DN 40/40A
RT Remote Threaded Seal
Process connections:
1/4 –18 NPT
1/2 –14 NPT
3/4 –14 NPT
1–11.5 NPT
page 101
SC Hygienic Tri Clamp Seal
Process connections:
11/2-in.
2-in.
3-in.
page 102
SS Hygienic Tank Spud Seal
Process connections:
4-in.
page 99
Emerson.com/Rosemount
69
Rosemount 3051S Series
October 2017
Table 8. Rosemount 3051SAL Transmitter for ERS Applications Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Options (include with selected model number)(2)(3)(4)(5)
Electronic remote sensor connection cable
R02
25 ft. (7,62 m) of Electronic Remote Sensors cable (gray color)
R05
50 ft. (15,2 m) of Electronic Remote Sensors cable (gray color)
★
R10
100 ft. (30,5 m) of Electronic Remote Sensors cable (gray color)
★
R15
150 ft. (45,72 m) of Electronic Remote Sensors cable (gray color)
★
R20(6)
200 ft. (60,96 m) of Electronic Remote Sensors cable (gray color)
R22(7)
225 ft. (68,58 m) of Electronic Remote Sensors cable (gray color)
R30
300 ft. (91,44 m) of Electronic Remote Sensors cable (gray color)
R40
400 ft. (121,92 m) of Electronic Remote Sensors cable (gray color)
R50
500 ft. (152,4 m) of Electronic Remote Sensors cable (gray color)
H02
25 ft. (7,62 m) of Electronic Remote Sensors cable (blue color)
H05
50 ft. (15,2 m) of Electronic Remote Sensors cable (blue color)
H10
100 ft. (30,5 m) of Electronic Remote Sensors cable (blue color)
H15
150 ft. (45,7 m) of Electronic Remote Sensors cable (blue color)
H20(6)
200 ft. (60,96 m) of Electronic Remote Sensors cable (blue color)
H22(7)
225 ft. (68,58 m) of Electronic Remote Sensors cable (blue color)
J02
25 ft. (7,62 m) of Electronic Remote Sensors armored cable
J05
50 ft. (15,2 m) of Electronic Remote Sensors armored cable
J07
75 ft. (22,8 m) of Electronic Remote Sensors armored cable
J10
100 ft. (30,5 m) of Electronic Remote Sensors armored cable
J12(7)
125 ft. (38,1 m) of Electronic Remote Sensors armored cable
Software configuration
C1(8)
★
Custom software configuration (requires Configuration Data Sheet)
Gage pressure calibration
C3
★
Gage pressure calibration on Rosemount 3051SAL_ _A4 only
Alarm limit(8)
C4
NAMUR alarm and saturation levels, high alarm
★
C5
NAMUR alarm and saturation levels, low alarm
★
C6
Custom alarm and saturation levels, high alarm (requires C1 and Configuration Data Sheet)
★
C7
Custom alarm and saturation levels, low alarm (requires C1 and Configuration Data Sheet)
★
C8
Low alarm (standard Rosemount alarm and saturation levels)
★
Ground screw
D4
70
External ground screw assembly
★
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 8. Rosemount 3051SAL Transmitter for ERS Applications Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Conduit plug
DO
316 SST conduit plug
★
Product certifications
E1
ATEX Flameproof
★
I1
ATEX Intrinsic Safety
★
N1
ATEX Type n
★
K1
ATEX Flameproof and Intrinsically Safe, Type n, Dust
★
ND
ATEX Dust
★
E4
TIIS Flameproof
★
E5
FM Explosion-proof, Dust Ignition-proof
★
I5
FM Intrinsically Safe, Division 2
★
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
E6(8)
CSA Explosion-proof, Dust Ignition-proof, Division 2
★
I6
CSA Intrinsically Safe
★
K6(8)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
E7
IECEx Flameproof
★
Product certifications
I7
IECEx Intrinsic Safety
★
N7
IECEx Type n
★
K7
IECEx Flameproof, Intrinsic Safety, Type n
★
E2
INMETRO Flameproof
★
I2
INMETRO Intrinsically Safe
★
K2
INMETRO Flameproof, Intrinsic Safety, Type n
★
KA(8)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2
★
KB(8)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2
★
KD(8)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe
★
Sensor fill fluid(8)
L1
Inert sensor fill fluid
★
Graphite-filled PTFE O-ring
★
O-ring
L2
Bolting material
L4
Austenitic 316 SST bolts
★
L5(9)
ASTM A 193, Grade B7M bolts
★
L6
Alloy K-500 bolts
★
Emerson.com/Rosemount
71
Rosemount 3051S Series
October 2017
Table 8. Rosemount 3051SAL Transmitter for ERS Applications Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
L7(9)
ASTM A 453, Class D, Grade 660 bolts
★
L8
ASTM A 193, Class 2, Grade B8M bolts
★
Display type (ERS primary only)(8)
M5
Plantweb LCD display
★
M7
Remote mount LCD display and interface, Plantweb housing, no cable, SST bracket
★
M8
Remote mount LCD display and interface, Plantweb housing, 50 ft. (15,2 m) cable, SST bracket
★
M9
Remote mount LCD display and interface, Plantweb housing, 100 ft. (30,5 m) cable, SST bracket
★
Special procedures
Pressure testing
P1
Hydrostatic testing with certificate
Special cleaning
P2
Cleaning for special services
P3
Cleaning for less than 1 PPM Chlorine/Fluorine
Special certifications
Calibration certification
Q4
Calibration certificate
★
QP
Calibration certificate with tamper evident seal
★
Material traceability certification
Q8
★
Material traceability certification per EN 10204 3.1
Toolkit performance reports(10)
QZ
★
Remote seal system performance calculation report
Transient protection(8)
T1
★
Transient terminal block
Typical model number: 3051SAL 1 P G 4A A 1A 1 0 20 D FF 7 1 DA 0 0 M5
1.
The pressure range should be specified based on the maximum static pressure, not differential pressure.
2.
At ambient pressure of 14.7 psia (1 bar-a) and ambient temperature of 70 °F (21 °C). Temperature limits are reduced in vacuum service and may be limited by seal
selection.
3.
Maximum process temperature is limited by heat transfer to the transmitter electronics and must be further derated if ambient, temperature exceeds
70 °F (21 °C).
4.
This is a food grade fill fluid.
5.
Not suitable for vacuum applications.
6.
Maxium cable distance for SIS installations. See section "6.1 Safety Instrumented Systems (SIS) Certification" of Rosemount 3051S ERS Reference Manual for more
information.
7.
Maxium cable distance for IS (Intrinsically safe) installations. Other options may not be valid at longer distances.
8.
Not available with M20 or G1/2 conduit entry size.
9.
Materials of construction comply with metallurgical requirements highlighted within NACE MR 0175/ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR 0103 for sour refining environments.
10.
The QZ report quantifies the performance of the entire ERS System. One report is provided per ERS System. The QZ option is specified on the primary transmitter
(Configuration Type code P).
72
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Rosemount 3051S Scalable Level Transmitter
Rosemount 3051SAL In-line
with “FF” Flanged Seal
Rosemount 3051S Scalable Level Transmitters combine the features and benefits of a
high-performance Rosemount 3051S with the durability and reliability of diaphragm
seals all in a single model number.
Product features and capabilities include:
Rosemount 3051SAL
Coplanar with “SS” Hygienic
Tank Spud Seal
Rosemount 3051SAL
Tuned-System
Assembly with
Thermal Range
Expander

Variety of process connections including flanged, threaded, and hygienic seals

Quantified performance for the entire transmitter/seal assembly (QZ option)

HART, FOUNDATION Fieldbus, and wireless protocols
Additional information
Specifications: page 104
Product Certifications: page 129
Dimensional drawings: page 145
Rosemount 3051SAL
Balanced System
Rosemount 3051SAL Scalable Level Transmitter
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 124 for more information on material selection.
A Rosemount 3051SAL consists of three parts. First, specify the transmitter model codes found on page 73.
Then, specify a direct mount seal found on page 85. Finish the model number by specifying all desired options on page 79.
Transmitter Model Codes_....... page 73
Diaphragm Seal Model Codes_.page 85
Options_______ page 70
Table 9. Rosemount 3051SAL Scalable Level Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Model
Transmitter type
3051SAL
Scalable level transmitter
Performance class(1)
1
Ultra: 0.055% span accuracy, 150:1 rangedown, 15-year limited warranty
★
2
Classic: 0.065% span accuracy, 150:1 rangedown
★
Configuration type
C
★
Liquid level transmitter
Pressure module type
D
Coplanar
Differential
★
G
Coplanar
Gage
★
Emerson.com/Rosemount
73
Rosemount 3051S Series
October 2017
Table 9. Rosemount 3051SAL Scalable Level Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
T
In-line
Gage
★
E
In-line
Absolute
★
A
Coplanar
Absolute
Pressure range
Coplanar DP
Coplanar gage
In-line gage
In-line
absolute
Coplanar absolute
1A
N/A
N/A
–14.7 to 30 psig
(–1,01 to 2,06 bar)
0 to 30 psia
(0 to 2,06 bar)
0 to 30 psia
(0 to 2,06 bar)
★
2A
–250 to 250 inH2O
(–621,60 to
621,60 mbar)
–250 to 250 inH2O
(–621,60 to
621,60 mbar)
–14.7 to 150 psig
(–1,01 to 10,34 bar)
0 to 150 psia
(0 to 10,34 bar)
0 to 150 psia
(0 to 10,34 bar)
★
3A
–1000 to 1000 inH2O
(–2,48 to 2,48 bar)
–393 to 1000 inH2O
(–0,97 to 2,48 bar)
–14.7 to 800 psig
(–1,01 to 55,15 bar)
0 to 800 psia
(0 to 55,15 bar)
0 to 800 psia
(0 to 55,15 bar)
★
4A
–300 to 300 psi
(–20,68 to 20,68 bar)
–14.2 to 300 psig
(–0,97 to 20,68 bar)
–14.7 to 4000 psig
(–1,01 to 275,79 bar)
0 to 4000 psia
(0 to 275,79 bar)
0 to 4000 psia
(0 to 275,79 bar)
★
5A
–2000 to 2000 psi
(–137,89 to 137,89 bar)
–14.2 to 2000 psig
(–0,97 to 137,89
bar)
–14.7 to 10000 psig
(–1,01 to 689,47 bar)
0 to 10000 psia
(0 to 689,47 bar)
N/A
★
Transmitter output
A
4–20 mA with digital signal based on HART protocol
★
F(2)
FOUNDATION Fieldbus protocol
★
X(3)
Wireless (requires wireless options and wireless Plantweb housing)
★
Housing style
Material
Conduit entry
1A
Plantweb housing
Aluminum
1 2
/ –14 NPT
★
1B
Plantweb housing
Aluminum
M20 ⫻ 1.5
★
1J
Plantweb housing
SST
1 2
/ –14 NPT
★
1K
Plantweb housing
SST
2A
Junction Box housing
2B
M20 ⫻ 1.5
★
Aluminum
1 2
/ –14 NPT
★
Junction Box housing
Aluminum
M20 ⫻ 1.5
★
2E
Junction Box with output for remote interface
Aluminum
1 2
/ –14 NPT
★
2F
Junction Box with output for remote interface
Aluminum
M20 ⫻ 1.5
★
2J
Junction Box housing
/ –14 NPT
★
5A(4)
/ –14 NPT
★
/ –14 NPT
★
★
SST
1 2
Wireless Plantweb housing
Aluminum
1 2
5J(4)
Wireless Plantweb housing
SST
1 2
7J(5)
Quick connect (a size mini, 4-pin male termination)
SST
N/A
1C
Plantweb housing
Aluminum
G/
1L
Plantweb housing
316L SST
G1/2
2C
Junction Box housing
Aluminum
G1/2
2G
Junction Box with output for remote interface
Aluminum
G1/2
74
1 2
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 9. Rosemount 3051SAL Scalable Level Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Seal system type
Coplanar pressure module type
In-line pressure module type
1
Direct mount single seal system
Welded-repairable
Direct mount single seal system
Weldedrepairable
★
2
Direct mount single seal system
All welded
N/A
N/A
★
3(6)
Tuned-system assembly - one direct
mount and one remote mount seal with
capillary
Welded-repairable
N/A
N/A
★
4(6)
Tuned-system assembly - one direct
mount and one remote mount seal with
capillary
All welded
N/A
N/A
★
5(6)
Balanced system - two remote mount seals
with equal lengths of capillary
Welded-repairable
N/A
N/A
★
6(6)
Balanced system - two remote mount seals
with equal lengths of capillary
All welded
N/A
N/A
★
7
Remote mount single seal system with
capillary - 316L low side transmitter
isolator
Welded-repairable
Remote mount single seal system
with capillary
All welded
★
8
Remote mount single seal system with
capillary - 316L low side transmitter
isolator
All welded
N/A
N/A
★
9
Remote mount single seal system with
capillary - Alloy C-276 low side transmitter
isolator
Welded-repairable
N/A
N/A
★
A
Remote mount single seal system with
capillary - Alloy C-276 low side transmitter
isolator
All welded
N/A
N/A
★
High side connection type [select based on seal system type chosen]
Single seal system
Dual seal system
Direct mount
Remote mount with capillary
Tunedsystem
assembly
Balanced
system
Coplanar
In-line
Coplanar
In-line
Coplanar
Coplanar
0
No extension
No extension
Standard
Standard
No extension/
Standard
Standard
★
2
2-in. (50 mm) extension
N/A
N/A
N/A
2-in. (50 mm)
extension
N/A
★
4
4-in. (100 mm)
extension
N/A
N/A
N/A
4-in.
(100 mm)
extension
N/A
★
Emerson.com/Rosemount
75
Rosemount 3051S Series
October 2017
Table 9. Rosemount 3051SAL Scalable Level Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
6(7)
7(7)
Thermal Range
Expander - Silicone 200
secondary fill
Thermal Range
Expander - SYLTHERM
XLT secondary fill fluid
Thermal Range
Expander - Silicone
200 secondary fill
Thermal Range
Expander Silicone 200
secondary fill fluid
single capillary
Thermal Range
Expander Silicone 200
secondary fill
single capillary
Thermal Range
Expander Silicone 200
secondary fill
with low side
capillary
Thermal
Range
Expander Silicone 200
secondary fill
with low side
capillary
★
Thermal Range
Expander SYLTHERM XLT
secondary fill fluid
Thermal Range
Expander SYLTHERM XLT
secondary fill fluid
single capillary
Thermal Range
Expander SYLTHERM XLT
secondary fill fluid
single capillary
Thermal Range
Expander SYLTHERM XLT
secondary fill
with low side
capillary
Thermal
Range
Expander SYLTHERM
XLT
secondary fill
with low side
capillary
★
Low side connection type or capillary I.D
Material for low side reference
connection
Capillary I.D.
Direct mount
Remote mount with capillary
Tunedsystem
assembly
Balanced
system
Coplanar
In-line
Coplanar or In-line
Coplanar
Coplanar
0
N/A
No reference
connection
N/A
N/A
N/A
★
1(8)(15)
Assemble to one
Rosemount 1199
remote seal
N/A
N/A
N/A
N/A
★
2
316L SST isolator and
SST transmitter flange
N/A
N/A
N/A
N/A
★
3
Alloy C-276 isolator and
SST transmitter flange
N/A
N/A
N/A
N/A
★
B
N/A
N/A
0.03-in. (0,711 mm) ID capillary
0.03-in.
(0,711 mm)
ID capillary
0.03-in.
(0,711 mm)
ID capillary
★
C
N/A
N/A
0.04-in. (1,092 mm) ID capillary
0.04-in.
(1,092 mm)
ID capillary
0.04-in.
(1,092 mm)
ID capillary
★
D
N/A
N/A
0.075-in. (1,905 mm) ID capillary
0.075-in.
(1,905 mm)
ID capillary
0.075-in.
(1,905 mm)
ID capillary
★
0.03-in. (0,711 mm) ID capillary, PVC
coated with closed end
0.03-in.
(0,711 mm)
ID capillary, PVC
coated with
closed end
0.03-in.
(0,711 mm)
ID capillary,
PVC coated
with closed
end
★
0.04-in. (1,092 mm) ID capillary, PVC
coated with closed end
0.04-in.
(1,092 mm)
ID capillary, PVC
coated with
closed end
0.04-in.
(1,092 mm)
ID capillary,
PVC coated
with closed
end
★
0.075-in. (1,905 mm) ID capillary, PVC
coated with closed end
0.075-in.
(1,905 mm)
ID capillary, PVC
coated with
closed end
0.075-in.
(1,905 mm)
ID capillary,
PVC coated
with closed
end
★
E
F
G
76
N/A
N/A
N/A
N/A
N/A
N/A
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 9. Rosemount 3051SAL Scalable Level Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Capillary length(9)
0
No capillary (required for direct mount single seal system)
★
A
1 ft. (0,3 m)
★
B
5 ft. (1,5 m)
★
C
10 ft. (3,0 m)
★
D
15 ft. (4,5 m)
★
E
20 ft. (6,1 m)
★
F
25 ft. (7,6 m)
★
G
30 ft. (9,1 m)
★
H
35 ft. (10,7 m)
★
J
40 ft. (12,2 m)
★
K
45 ft. (13,7 m)
★
L
50 ft. (15,2 m)
★
M
1.6 ft. (0,5 m)
★
N
3.3 ft. (1,0 m)
★
P
4.9 ft. (1,5 m)
★
R
6.6 ft. (2,0 m)
★
T
8.2 ft. (2,5 m)
★
U
9.8 ft. (3,0 m)
★
V
11.5 ft. (3,5 m)
★
W
13.1 ft. (4,0 m)
★
Y
16.4 ft. (5,0 m)
★
Z
19.7 ft. (6,0 m)
★
1
23 ft. (7,0 m)
★
2
26.2 ft. (8,0 m)
★
3
29.5 ft. (9,0 m)
★
4
32.8 ft. (10,0 m)
★
5
36.1 ft. (11,0 m)
★
6
39.4 ft. (12,0 m)
★
7
42.6 ft. (13,0 m)
★
8
45.9 ft. (14,0 m)
★
9
49.2 ft. (15,0 m)
★
Emerson.com/Rosemount
77
Rosemount 3051S Series
October 2017
Table 9. Rosemount 3051SAL Scalable Level Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Temperature limits(10)
Specific gravity
at 77 °F (25 °C)
Seal fill fluid
No extension
2-in. (50 mm)
extension
4-in.
(100 mm)
extension
Thermal
range
expander
(process
temperature)
(11)
D
Silicone 200
0.93
–49 to 401 °F
(–45 to 205 °C)
–49 to 401 °F
(–45 to 205 °C)
F
Silicone 200 for vacuum
applications
0.93
For use in vacuum applications below 14.7 psia (1 bar-a), refer to vapor
pressure curves in Rosemount DP Level Fill Fluid Specifications
Technical Note.
★
L
Silicone 704
1.07
32 to 401 °F(12)
(0 to 205 °C)
★
C
Silicone 704 for vacuum
applications
1.07
For use in vacuum applications below 14.7 psia (1 bar-a), refer to vapor
pressure curves in Rosemount DP Level Fill Fluid Specifications
Technical Note.
★
R
Silicone 705
1.09
68 to 401 °F(12)
(20 to 205 °C)
★
V
Silicone 705 for vacuum
applications
1.09
For use in vacuum applications below 14.7 psia (1 bar-a), refer to vapor
pressure curves in Rosemount DP Level Fill Fluid Specifications
Technical Note.
Y (13)
UltraTherm™ 805
1.20
Z(13)
UltraTherm 805 for
vacuum applications
1.20
A
SYLTHERM XLT
0.85
-157 to 293 °F
(-105 to 145 °C)
-157 to 293 °F
(-105 to 145 °C)
-157 to 293 °F
(-105 to 145 °C)
N/A
★
H
Inert (Halocarbon)
1.85
-49 to 320 °F
(-45 to 160 °C)
-49 to 320 °F
(-45 to 160 °C)
-49 to 320 °F
(-45 to 160 °C)
N/A
★
N(14)
Neobee M-20
0.92
5 to 401 °F(12)
(-15 to 205 °C)
5 to 437 °F
(-15 to 225 °C)
5 to 437 °F
(-15 to 225 °C)
N/A
★
G(14)(15)
Glycerin and water
1.13
5 to 203 °F
(-15 to 95 °C)
5 to 203 °F
(-15 to 95 °C)
5 to 203 °F
(-15 to 95 °C)
N/A
★
P (14)(15)
Propylene glycol and
water
1.02
5 to 203 °F
(-15 to 95 °C)
5 to 203 °F
(-15 to 95 °C)
5 to 203 °F
(-15 to 95 °C)
N/A
★
32 to 464 °F(12)
(0 to 240 °C)
68 to 464 °F(12)
(20 to 240 °C)
–49 to 401 °F
(–45 to 205 °C)
32 to 500 °F(12)
(0 to 260 °C)
68 to 500 °F(12)
(20 to 260 °C)
N/A
Up to 599 °F
(315 °C)
Up to 698 °F
(370 °C)
★
★
Up to 770 °F
(410 °C)
★
For use in vacuum application below 14.7 psia (1 bar-a), refer to vapor pressure
curves in Rosemount DP Level Fill Fluid Specifications
Technical Note.
★
N/A
N/A
N/A
Continue specifying a completed model number by choosing a remote seal type below:
Process connections
Seal style
page 85
78
FF Flush Flanged Seal
2-in./DN 50/ 50A
3-in./DN 80/80A
4 in./DN 100/100A
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 9. Rosemount 3051SAL Scalable Level Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
EF Extended Flanged Seal
3-in./DN 80/80A
4-in./DN 100/100A
page 90
RF Remote Flanged Seal
/ -in.
/ -in.
1-in./DN 25/25A
11/2-in./DN 40/40A
page 92
PF Pancake Seal
page 95
FC Flush Flanged Seal - Ring Type Joint (RTJ) Gasket Surface
page 88
1 2
3 4
2-in./DN 50/50A
3-in./DN 80/80A
2-in.
3-in.
/ -in
/ -in
1 in.
11/2-in.
1 2
page 97
RC Remote Flange Seal - Ring Type Joint (RJT) Gasket
Surface
3 4
page 99
RT Remote Threaded Seal
/ –18 NPT
/ –14 NPT
3/4–14 NPT
1–11.5 NPT
11/4–11.5 NPT
page 101
SC Hygienic Tri Clamp Seal
11/2-in.
2-in.
3-in.
page 102
SS Hygienic Tank Spud Seal
4-in.
1 4
1 2
Wireless options (requires option code X and wireless Plantweb housing)
Update rate(4)
WA
User configurable update rate
★
Operating frequency and protocol
3
2.4 GHz DSSS, IEC 62591 (WirelessHART)
★
Omni-directional wireless antenna
WK(4)
External antenna
★
WM(4)
Extended range, external antenna
★
WN
High-gain, remote antenna
Emerson.com/Rosemount
79
Rosemount 3051S Series
October 2017
Table 9. Rosemount 3051SAL Scalable Level Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
SmartPower(16)(17)
1
★
Adapter for Black Power Module (I.S. Power Module sold separately)
Other options (include with selected model number)
HART Revision configuration (requires HART Protocol output code A)(18)
HR7
★
Configured for HART Revision 7
Extended product warranty
WR3
3-year limited warranty
★
WR5
5-year limited warranty
★
Plantweb control functionality(17)(19)(20)
A01
★
FOUNDATION Fieldbus advanced control function block suite
Plantweb diagnostic functionality
D01(17)(19)
FOUNDATION Fieldbus diagnostics suite
★
DA2(21)
Advanced HART diagnostics suite
★
Mounting bracket
B4
★
Bracket, all SST, 2-in. pipe panel
Software configuration(22)
C1
★
Custom software configuration (requires Configuration Data Sheet)
Gage pressure calibration
C3
★
Gage pressure calibration on Rosemount 3051SAL_ _A4 only
Alarm limit(19)(22)
C4
NAMUR alarm and saturation levels, high alarm
★
C5
NAMUR alarm and saturation levels, low alarm
★
C6
Custom alarm and saturation signal levels, high alarm (requires C1 and Configuration Data Sheet)
★
C7
Custom alarm and saturation signal levels, low alarm (requires C1 and Configuration Data Sheet)
★
C8
Low alarm (standard Rosemount alarm and saturation levels)
★
Hardware adjustments(19)(22)(23)
D1
Hardware adjustments (zero, span, alarm, security)
★
Flange adapter
D2
1 2
/ –14 NPT flange adapter
D9
RC 1/2 SST flange adapter
★
Ground screw(24)
D4
80
External ground screw assembly
★
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 9. Rosemount 3051SAL Scalable Level Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Drain/vent valve
D5
Delete transmitter drain/vent valves (install plugs)
★
Conduit plug(25)
DO
316 SST conduit plug
★
Product certifications(26)
E1
ATEX Flameproof
★
I1
ATEX Intrinsic Safety
★
IA
ATEX FISCO Intrinsic Safety (FOUNDATION Fieldbus protocol only)
★
N1
ATEX Type n
★
K1
ATEX Flameproof, Intrinsic Safety, Type n, Dust
★
ND
ATEX Dust
★
E4
TIIS Flameproof
★
E5
FM Explosion-proof, Dust Ignition-proof
★
I5
FM Intrinsically Safe; Nonincendive
★
IE
FM FISCO Intrinsically Safe (FOUNDATION Fieldbus protocol only)
★
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
E6(27)
CSA Explosion-proof, Dust Ignition-proof, Division 2
★
I6
CSA Intrinsically Safe
★
IF
CSA FISCO Intrinsically Safe (FOUNDATION Fieldbus protocol only)
★
K6(27)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
D3(28)
Measurement Canada Accuracy Approval
★
E7
IECEx Flameproof, Dust Ignition-proof
★
I7
IECEx Intrinsic Safety
★
IG
IECEx FISCO Intrinsic Safety (FOUNDATION Fieldbus protocol only)
★
N7
IECEx Type n
★
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n
★
E2
INMETRO Flameproof
★
I2
INMETRO Intrinsic Safety
★
IB
INMETRO FISCO Intrinsic Safety
★
K2
INMETRO Flameproof, Intrinsic Safety
★
E3
China Flameproof
★
I3
China Intrinsic Safety, Dust Ignition-proof
★
EP
Korea Flameproof
★
IP
Korea Intrinsic Safety
★
KP
Korea Flameproof, Intrinsic Safety
★
Emerson.com/Rosemount
81
Rosemount 3051S Series
October 2017
Table 9. Rosemount 3051SAL Scalable Level Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
EM
Technical Regulations Customs Union (EAC) Flameproof
★
IM
Technical Regulations Customs Union (EAC) Intrinsic Safety
★
KM
Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety
★
KA(27)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2
★
KB(27)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2
★
KD(27)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe
★
Shipboard approvals
SBS
American Bureau of Shipping (ABS) Type Approval
★
SBV
Bureau Veritas (BV) Type Approval
★
SDN
Det Norske Veritas (DNV) Type Approval
★
SLL
Lloyds Register (LR) Type Approval
★
Sensor fill fluid(29)
L1
Inert sensor fill fluid
★
Graphite-filled PTFE O-ring
★
O-ring
L2
Bolting material
L4
Austenitic 316 SST bolts
★
L5(30)
ASTM A193, Grade B7M bolts
★
L6
Alloy K-500 bolts
★
L7(30)
ASTM A453, Class D, Grade 660 bolts
★
L8
ASTM A193, Class 2, Grade B8M bolts
★
Display type(31)
Plantweb LCD display
★
(33)
Remote mount LCD display and interface, Plantweb housing, no cable, SST bracket
★
M8(19)(32)
Remote mount LCD display and interface, Plantweb housing, 50 ft (15 m) cable, SST bracket
★
M9(19)(32)
Remote mount LCD display and interface, Plantweb housing, 100 ft (31 m) cable, SST bracket
★
M5
M7(19)(32)
Pressure testing
P1
Hydrostatic testing with certificate
Special cleaning
P2
Cleaning for special services
P3
Cleaning for special services with testing for <1PPM chlorine/fluorine
82
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 9. Rosemount 3051SAL Scalable Level Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Calibration certification
Q4
Calibration certificate
★
QP
Calibration certificate and tamper evident seal
★
Material traceability certification
Q8
★
Material traceability certification per EN 10204 3.1
Quality certification for safety
QS(19)(22)
Prior-use certificate of FMEDA Data
★
QT(34)
Safety-certified to IEC 61508 with certificate of FMEDA data
★
Toolkit performance reports
QZ
★
Remote seal system performance calculation report
Transient protection(35)(36)
T1
★
Transient terminal block
Conduit electrical connector(37)
GE
M12, 4-pin, male connector (eurofast)
★
GM
A size mini, 4-pin, male connector (minifast)
★
NACE certificate(30)
Q15
Certificate of compliance to NACE MR0175/ISO 15156 for wetted materials
★
Q25
Certificate of compliance to NACE MR0103 for wetted materials
★
Typical model number:
3051SAL 1 C G 2A A 1A 10 20 D FF G 1 DA 0 0
1.
For detailed specifications see “Specifications” on page 104. The Rosemount 3051S ERS System offers three performance class options; Classic, Ultra, and Enhanced
ERS System Performance. The Classic and Ultra performance classes are suited to lower static pressure and stable temperature conditions. The Enhanced ERS System
Performance class provides better performance across temperature (–40 to 185 °F) with improved performance at higher static pressure.
2.
Requires Plantweb housing.
3.
Only intrinsically safe approval codes apply.
4.
Only available with output code X.
5.
Available with output code A only. Available approvals are FM Intrinsically Safe; Nonincendive (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic
Safety (option code I1), or IECEx Intrinsic Safety (option code I7). Contact an Emerson Process Management representative for additional information.
6.
Low side seal identical to high side seal.
7.
Maximum working pressure (MWP) of the Thermal Range Expander is 1500 psi (103,4 bar).
8.
Requires separate Rosemount 1199 model number to be selected. With option code 1, user must select Seal Location Option code M (low side of transmitter) in the
Rosemount 1199 Remote Mount Seal System Model.
9.
Capillary Length applies to both high and low side for Balanced Systems. Applies to Low Side Only For Tuned-System Assemblies. Applies to High Side Only for Remote
Mount Single Seal Systems with Capillary.
10.
At ambient pressure of 14.7 psia (1 bar-a) and ambient temperature of 70 °F (21 °C). Temperature limits are reduced in vacuum service and may be limited by seal
selection.
11.
For complete process and ambient temperature limits, see “Thermal Range Expander temperature operating range” on page 123.
12.
Maximum process temperature is limited by heat transfer to the transmitter electronics and must be further derated if ambient temperature exceeds 70 °F
(21 °C).
13.
Only available with Thermal Range Expander.
14.
This is a food grade fill fluid.
15.
Not suitable for vacuum applications.
Emerson.com/Rosemount
83
Rosemount 3051S Series
October 2017
16.
Long-Life Power Module must be shipped separately, order Power Module 701PBKKF.
17.
Not available with output code A.
18.
Option HR7 configures the HART output to HART Revision 7. This option requires the selection of the Advanced Diagnostics (DA2) option. The device with this option
can be field configured to HART Revision 5 or 7 if desired.
19.
Not available with output code X.
20.
With option code 10, user must select Seal Location option code M in Table 7 of Rosemount DP Level PDS.
21.
Requires Plantweb housing and Output code A. Includes Hardware Adjustments as standard.
22.
Not available with output code F.
23.
Not available with housing style codes 2E, 2F, 2G, 2M, 5A, 5J, or 7J.
24.
This assembly is included with options EP, KP, E1, N1, K1, ND, E4, E7, N7, K7, E2, E3, KA, KC, KD. IA, IB, IE. IF, IG, K2, T1, EM, and KM.
25.
Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of carbon steel conduit plug.
26.
Valid when SuperModule Platform and housing have equivalent approvals.
27.
Not available with M20 or G 1/2 conduit entry size.
28.
Requires Plantweb housing and Hardware Adjustments option code D1. Limited availability depending on transmitter type and range. Contact an Emerson
representative for additional information.
29.
Silicone fill fluid is standard.
30.
Materials of construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
Order with Q15 or Q25 to receive a NACE certificate.
31.
Not available with housing code 01 or 7J.
32.
Not available with output code F, option code DA2, or option code QT.
33.
See the Rosemount 3051S Reference Manual for cable requirements. Contact an Emerson representative for additional information.
34.
Not available with output code F or X. Not available with housing code 7J.
35.
Not available with Housing code 5A, 5J, or 7J.
36.
The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IB, IE, IF, and IG.
37.
Not available with Housing code 5A, 5J, or 7J. Available with Intrinsically Safe approvals only. For FM Intrinsically Safe; Nonincendive (option code I5) or FM FISCO
Intrinsically Safe (option code IE), install in accordance with Rosemount drawing 03151-1009.
84
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Diaphragm seals for Rosemount 3051SAL
Flush Flanged (FF) Seal

Most common seal

Good for use in general applications

Easy installation on flanged connections ranging from 2-in. (DN 50) to 4-in. (DN 100)
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 124 for more information on material selection.
Table 10. Flush Flanged (FF) Seal Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Model
Process connection
FF
Flush flanged seal
Process connection size
ANSI/ASME B16.5
EN 1092-1/GOST 12815-80
JIS B2238
G
2-in.
DN 50
50 A
★
7
3-in.
N/A
80 A
★
J
N/A
DN 80
N/A
★
9
4-in.
DN 100
100 A
★
Flange/pressure rating
1
ANSI/ASME B16.5 Class 150
★
2
ANSI/ASME B16.5 Class 300
★
4
ANSI/ASME B16.5 Class 600
★
G
PN 40 per EN 1092-1
★
5
ANSI/ASME B16.5 Class 900
6
ANSI/ASME B16.5 Class 1500
7
ANSI/ASME B16.5 Class 2500
H
PN 63 per EN 1092-1
J
PN 100 per EN 1092-1
A
10K per JIS B2238
B
20K per JIS B2238
D
40K per JIS B2238
E
PN 10/16 per EN 1092-1, available with DN 100 only
Materials of construction
Isolating diaphragm
Upper housing
Flange
CA
316L SST
316L SST
CS
★
DA
316L SST
316L SST
316 SST
★
CB(1)
Alloy C-276
316L SST
CS
★
DB(1)
Alloy C-276, seam-welded
316L SST
316 SST
★
Emerson.com/Rosemount
85
Rosemount 3051S Series
October 2017
Table 10. Flush Flanged (FF) Seal Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
CC
Tantalum
316L SST
CS
★
DC
Tantalum, seam-welded
316L SST
316 SST
★
Flushing connection ring (lower housing)(2)
0
None
★
A
316 SST
★
B
Alloy C-276
★
Flushing connection quantity and size
0
None
★
1
One / –18 NPT flushing connection
★
3
Two 1/4–18 NPT flushing connections
★
7
One 1/2–14 NPT flushing connection
★
9
Two 1/2–14 NPT flushing connections
★
1 4
Options (include with selected model number)
Cold temperature remote seal applications
RB
Extra fill fluid for cold temperature applications
Remote seal diaphragm thickness(3)
SC
0.006-in. (150 μm) available with 316L SST and Alloy C-276
Flushing connection ring plugs
SF
Alloy C-276 plug(s) for flushing connection(s)
★
SG
SST plug(s) for flushing connection(s)
★
SH
SST drain/vent(s) for flushing connection(s)
★
Intermediate gasket material
S0
No gasket for flushing ring connection (lower housing)
★
SY
Thermo-tork® TN-9000
★
SJ
PTFE gasket
★
SK
Barium Sulfate-filled PTFE gasket
SN
GRAFOIL gasket
Remote seal diaphragm coating
SZ(3)
0.0002-in. (5 μm) gold-plated diaphragm
SV
PTFE coated diaphragm for non-stick purposes
86
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 10. Flush Flanged (FF) Seal Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Complete the 3051SAL model number by specifying options as needed:
page 70
ERS Transmitter options
page 80
Scalable Level Transmitter options
1.
Not available with option code SC.
2.
Supplied with Thermo-tork TN-9000 gasket if no other flushing connection ring gasket option is selected.
3.
Not available with Tantalum diaphragms (Material of Construction codes CC and DC).
Emerson.com/Rosemount
87
Rosemount 3051S Series
October 2017
Extended Flanged (EF) Seal



Good for use in viscous applications with plugging issues
Seal diaphragm installed flush with inner tank wall to prevent process plugging
Easy installation on 3-in. (DN 80) and 4-in. (DN 100) flanged connections
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 124 for more information on material selection.
Table 11. Extended Flanged (EF) Seal Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Model
Process connection
EF
Extended flanged seal
Process connection size
ANSI/ASME B16.5
EN 1092-1/GOST 12815-80
JIS B2238
Extension diameters
7
3-in. schedule 80
DN 80
80A
2.58-in. (66 mm)
★
9
4-in. schedule 80
DN 100
100A
3.50-in. (89 mm)
★
Flange/pressure rating
1
ANSI/ASME B16.5 Class 150
★
2
ANSI/ASME B16.5 Class 300
★
4
ANSI/ASME B16.5 Class 600
★
G
PN 40 per EN 1092-1
★
5
ANSI/ASME B16.5 Class 900
6
ANSI/ASME B16.5 Class 1500
7
ANSI/ASME B16.5 Class 2500
H
PN 63 per EN 1092-1
J
PN 100 per EN 1092-1
A
10K per JIS B2238
B
20K per JIS B2238
D
40K per JIS B2238
E
PN 10/16 per EN 1092-1, available with DN 100 only
Materials of construction
Isolating diaphragm
Extension/gasket surface
Mounting flange
CA
316L SST
316L SST
CS
★
DA
316L SST
316L SST
316 SST
★
CB
Alloy C-276
Alloy C-276
CS
★
DB
Alloy C-276
Alloy C-276
316 SST
★
88
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 11. Extended Flanged (EF) Seal Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Seal extension length
20
2-in. (50 mm)
★
40
4-in. (100 mm)
★
60
6-in. (150 mm)
★
Options (include with selected model number)
Cold temperature remote seal applications
RB
Extra fill fluid for cold temperature applications
★
Remote seal diaphragm thickness
SC
0.006-in. (150 μm) diaphragm thickness
Remote seal diaphragm coating
SZ
0.0002-in. (5 μm) gold-plated diaphragm
SV
PTFE coated diaphragm for non-stick purposes
Complete the 3051SAL model number by specifying options as needed:
page 70
ERS Transmitter options
page 80
Scalable Level Transmitter options
Emerson.com/Rosemount
89
Rosemount 3051S Series
October 2017
Remote Flanged (RF) Seal

Designed to improve performance on smaller process connections

Easy installation on flanged connections ranging from 1/2- to 11/2-in. (DN 25– DN 40)

Lower housing/flushing ring required
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 124 for more information on material selection.
Table 12. Remote Flanged (RF) Seal Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Model
Process connection
RF
Remote flanged seal
Process connection size
ANSI/ASME B16.5
EN 1092-1/GOST 12815-80
JIS B2238
2
1-in.
N/A
25A
★
4
11/2-in.
N/A
40A
★
D
N/A
DN 25
N/A
★
F
N/A
DN 40
N/A
★
1
1 2
/ -in.
N/A
N/A
A
3 4
/ -in.
N/A
N/A
Flange/pressure rating
1
ANSI/ASME B16.5 Class 150
★
2
ANSI/ASME B16.5 Class 300
★
4
ANSI/ASME B16.5 Class 600
★
G
PN 40 per EN 1092-1
★
5
ANSI/ASME B16.5 Class 900
6
ANSI/ASME B16.5 Class 1500
7
ANSI/ASME B16.5 Class 2500
A
10K per JIS B2238
B
20K per JIS B2238
D
40K per JIS B2238
Materials of construction
Isolating diaphragm
Upper housing
Flange
CA
316L SST
316L SST
CS
★
DA
316L SST
316L SST
316 SST
★
CB
Alloy C-276
316L SST
CS
★
DB
Alloy C-276
316L SST
316 SST
★
CC
Tantalum
316L SST
CS
★
DC
Tantalum
316L SST
316 SST
★
90
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 12. Remote Flanged (RF) Seal Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Flushing connection ring material (lower housing)(1)
A
316L SST
★
B
Alloy C-276
★
Flushing connection quantity and size
5
None
★
1
One / –18 NPT flushing connection
★
3
Two / –18 NPT flushing connections
★
7
One / –14 NPT flushing connection
9
Two 1/2–14 NPT flushing connections
1 4
1 4
1 2
Options (include with selected model number)
Cold temperature remote seal application
RB
Extra fill fluid for cold temperature applications
★
Remote seal diaphragm thickness
SC(2)
0.006-in. (150 μm) available in 316L SST and Alloy C-276
Flushing connection ring plugs
SF
Alloy C-276 plug(s) for flushing connection(s)
★
SG
316 SST plug(s) for flushing connection(s)
★
SH
316 SST drain/vent(s) for flushing connection(s)
★
Intermediate gasket material
SY
C-4401 gasket
★
SJ
PTFE gasket
★
SR
Ethylene Propylene gasket
SN
GRAFOIL gasket
S6
TopChem 2000
SK
Barium Sulfate-filled PTFE gasket
Remote seal diaphragm coating
SZ(2)
0.0002-in. (5 μm) gold-plated diaphragm
SV
PTFE coated diaphragm for non-stick purposes
Remote seal bolt
S3
304 SST bolts
S4
316 SST bolts
★
Complete the 3051SAL model number by specifying options as needed:
page 70
ERS Transmitter options
page 80
Scalable Level Transmitter options
1.
Supplied with C-4401 Aramid fiber gasket if no other remote seal gasket material is selected.
2.
Not available with Tantalum diaphragms (Material of Construction codes CC and DC).
Emerson.com/Rosemount
91
Rosemount 3051S Series
October 2017
PF Pancake Seal

Remote mount connection with capillary on the side of the seal

Support tube used to facilitate installation

Can be ordered with or without flange
Table 13. PF Pancake Seal Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Model
Process connection
PF(1)
Pancake seal
★
Process connection size
ANSI
EN 1092-1/GOST 12815-80
JIS B2238
G
2-in.
DN 50
50A
★
7
3-in.
N/A
80A
★
J
N/A
DN 80
N/A
★
Flange/pressure rating
ANSI
EN 1092-1/GOST 12815-80
0
No flanged supplied, seal MWP based on customer
supplied flange
N/A
★
9
N/A
No flanged supplied, seal MWP based on customer
supplied flange
★
1
Class 150
N/A
★
2
Class 300
N/A
★
4
Class 600
N/A
★
G
N/A
PN40
★
5
Class 900
N/A
6
Class 1500
N/A
7
Class 2500
N/A
H
N/A
PN63
J
N/A
PN100
Diaphragm and wetted, upper housing, flange material
Diaphragm and wetted
Upper housing
Flange
LA
316L SST
316L SST
None
★
CA
316L SST
316L SST
CS
★
DA
316L SST
316L SST
316 SST
★
LB
Alloy C-276, seam welded
316L SST
None
★
CB
Alloy C-276, seam welded
316L SST
CS
★
DB
Alloy C-276, seam welded
316L SST
316 SST
★
92
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 13. PF Pancake Seal Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
LC
Tantalum, seam welded
316L SST
None
★
CC
Tantalum, seam welded
316L SST
CS
★
DC
Tantalum, seam welded
316L SST
316 SST
★
Flushing connection ring (lower housing)(2)
0
None
★
A
316 SST
★
B
Alloy C-276
★
Flushing connection quantity and size
0
None
★
1
One 1/4–18 NPT flushing connection
★
3
Two 1/4–18 NPT flushing connections
★
7
One 1/2–14 NPT flushing connection
★
9
Two / –14 NPT flushing connections
★
1 2
Options (include with selected model number)
Intermediate gasket material
S0
No gasket for flushing ring connection (lower housing)
★
SY
Thermo-tork TN-9000
★
SJ
PTFE gasket
★
SK
Barium Sulfate-filled PTFE gasket
SN
GRAFOIL gasket
Flushing connection ring plugs
SF
Alloy C-276 plug(s) for flushing connection(s)
★
SG
SST plug(s) for flushing connection(s)
★
SH
SST drain/vent(s) for flushing connection(s)
★
Remote seal diaphragm thickness(3)
SC
0.006-in. (150 μm) diaphragm thickness
Cold temperature remote seal applications
RB
Extra fill fluid for cold temperature applications
Emerson.com/Rosemount
93
Rosemount 3051S Series
October 2017
Table 13. PF Pancake Seal Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Remote seal diaphragm coating
SZ(3)
0.0002-in. (5 μm) gold-plated diaphragm
SV
PTFE coated diaphragm for non-stick purposes
Complete the 3051SAL model number by specifying options as needed:
page 80
Scalable Level Transmitter options
1.
Not available with Direct Mount Seal System types 1, 2, 3, or 4.
2.
Supplied with Thermo-tork TN-9000 gasket if no other flushing connection ring gasket option is selected.
3.
Not available with Tantalum diaphragms (Material of Construction codes CC and DC).
94
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
FC Flush Flanged Seal - Ring Type Joint (RTJ) gasket surface

RTJ gaskets are metallic sealing rings, often used in high pressure/high temperature applications

Gasket surface on seal contains groove for RTJ gasket (user supplied)
Table 14. FC Flush Flanged Seal - Ring Type Joint (RTJ) Gasket Surface Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Model
Process connection
FC
Flush flanged seal - Ring Type Joint (RTJ) gasket surface
Process connection size
G
2-in.
7
3-in.
9
4-in.
Flange/pressure rating
1
Class 150
2
Class 300
4
Class 600
5
Class 900
6
Class 1500
7
Class 2500
Diaphragm and wetted, upper housing, flange material
Diaphragm and wetted
Upper housing
Flange
DA
316L SST
316L SST
316 SST
KB
Alloy C-276
316L SST
316 SST
MB
Alloy C-276
316L SST
CS
CA
316L SST
316L SST
CS
Flushing connection ring material (lower housing)
0
None
A
316 SST
B
Alloy C-276
Flushing connection quantity and size
0
None
1
One 1/4–18 NPT flushing connection
3
Two 1/4–18 NPT flushing connection
7
One 1/2–14 NPT flushing connection
9
Two 1/2–14 NPT flushing connection
Emerson.com/Rosemount
95
Rosemount 3051S Series
October 2017
Table 14. FC Flush Flanged Seal - Ring Type Joint (RTJ) Gasket Surface Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Options (include with selected model number)
Flushing ring connection plugs
SF
Alloy C-276 plug(s) for flushing connection(s)
SG
316 SST plug(s) for flushing connection(s)
SH
316 SST vent/drain for flushing connection(s)
Remote seal diaphragm thickness
0.006-in. (150 μm) available with 316L SST, Alloy C-276, and duplex 2507 SST for abrasive applications
SC
Cold temperature remote seal application
RB
Extra fill for cold temp application
Remote seal diaphragm coating(1)
SZ
0.002-in. (5 μm) gold-plated diaphragm
SV
PTFE coated diaphragm for nonstick purposes only
Complete the 3051SAL model number by specifying options as needed:
page 70
ERS Transmitter options
page 80
Scalable Level Transmitter options
1.
96
Only available on 316LSST and Alloy C-276.
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
RC Remote Flanged Seal - Ring Type Joint (RTJ) gasket surface

Remote mounted with capillary

RTJ gaskets are metallic sealing rings, often used in high pressure/high temperature applications

Gasket surface on seal contains groove for RTJ gasket (user supplied)
Table 15. RC Remote Flanged Seal - Ring Type Joint (RTJ) Gasket Surface
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Model
Process connection
RC
Remote flanged seal - Ring Type Joint (RTJ) gasket surface
Process connection sizes
1
1 2
/ -in. (Class 150 to 1500 includes mounting ring bolts and mounting studs)
A
3 4
2
1-in.
4
11/2-in.
/ -in. (Class 150 includes mounting ring bolts and mounting studs)
Flange/pressure rating
1
Class 150
2
Class 300
4
Class 600
5
Class 900
6
Class 1500
7
Class 2500
Diaphragm and wetted, upper housing, flange material
Diaphragm and wetted
Upper housing
Flange
CA
316L SST
316L SST
CS
★
DA
316L SST
316L SST
316 SST
★
CB
Alloy C-276
316L SST
CS
★
DB
Alloy C-276
316L SST
316 SST
★
CC
Tantalum
316L SST
CS
★
DC
Tantalum
316L SST
316 SST
★
Flushing connection ring material (lower housing)
A
316L SST
B
Alloy C-276
Flushing ring connection and size
0
None
1
One 1/4–18 NPT flushing connections
3
Two 1/4–18 NPT flushing connection
7
One 1/2–14 NPT flushing connection
9
Two 1/2–14 NPT flushing connection
Emerson.com/Rosemount
97
Rosemount 3051S Series
October 2017
Table 15. RC Remote Flanged Seal - Ring Type Joint (RTJ) Gasket Surface
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Options (include with selected model number)
Intermediate gasket material
SY
C-4401 gasket
SJ
PTFE gasket
SR
Ethylene Propylene gasket
SN
GRAFOIL gasket
S6
TopChem 2000
SK
Barium Sulfate-filled PTFE gasket
Remote seal bolt
S3
304 SST bolts
S4
316 SST bolts
★
Flushing connection ring plugs
SF
Alloy C-276 plug(s) for flushing connection(s)
SG
316 SST plug(s) for flushing connection(s)
SH
316 SST vent/drain for flushing connection(s)
Remote seal diaphragm thickness
0.006-in. (150 μm) available with 316L SST, Alloy C-276, and duplex 2507 SST for abrasive applications
SC
Bolt material (optional)(1)
S3
304 SST bolts (only available for stud bolt design)
S4
316 SST bolts
Cold temperature remote seal application
RB
Extra fill for cold temp application
Remote seal diaphragm coating
SZ(2)
0.002-in. (5 μm) gold-plated diaphragm
SV(1)
PTFE coated diaphragm for nonstick purposes only
Complete the 3051SAL model number by specifying options as needed:
page 70
ERS Transmitter options
page 80
Scalable Level Transmitter options
1.
Standard stud bolts are carbon steel.
2.
Only available on 316LSST and Alloy C-276.
98
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Remote Threaded (RT) Seal

For use with threaded process connections (1/4-18 to 1-11.5 NPT)

Rated for use in high-pressure applications (up to 2500 PSI)

Optional flushing connections available
Table 16. RT Threaded Seal Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Model
Process connection
RT
Remote threaded seal
★
Process connection size
/ -14 NPT
★
3 4
/ -14 NPT
★
5
1-11.5 NPT
★
1
1 4
6
11/4 - 11.5 NPT
3
1 2
4
/ -18 NPT
Pressure rating
0
★
2500 psi
Isolating diaphragm material
Upper housing material
Flange
CA
316L SST
316L SST
CS
★
DA
316L SST
316L SST
316 SST
★
CB
Alloy C-276
316L SST
CS
★
DB
Alloy C-276
316L SST
316 SST
★
CC
Tantalum
316L SST
CS
★
DC
Tantalum
316L SST
316 SST
★
Flushing connection ring material (lower housing)(1)(2)
A
316L SST
★
B
Alloy C-276
★
Flushing ring connection quantity and size
5
None
★
1
One 1/4-in. flushing connection
★
3
Two 1/4-in. flushing connections
★
7
One 1/2-14 NPT flushing connection
9
Two 1/2-14 NPT flushing connection
Emerson.com/Rosemount
99
Rosemount 3051S Series
October 2017
Table 16. RT Threaded Seal Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Options (include with selected model number)
Cold temperature remote seal application
RB
Extra fill fluid for cold temperature applications
★
Remote seal diaphragm thickness
SC(3)
0.006-in. (150 μm) diaphragm thickness
Remote seal flushing plug, drain/vent
SF
Alloy C-276 plug(s) for flushing connection(s)
★
SG
316 SST plug(s) for flushing connection(s)
★
SH
316 SST drain/vent(s) for flushing connection(s)
★
Intermediate gasket material
SY
C-4401 gasket (for use with flushing connection ring)
★
SJ
PTFE gasket (for use with flushing connection ring)
★
SR
Ethylene Propylene gasket (for use with flushing connection ring)
★
SN
GRAFOIL gasket (for use with flushing connection ring)
★
S6
TopChem 2000 (for use with flushing connection ring)
SK
Barium Sulfate-filled PTFE gasket (for use with flushing connection ring)
Remote seal bolt
S3
304 SST bolts
S4
316 SST bolts
★
Remote seal diaphragm coating
SZ(3)
0.0002-in. (5 μm) gold-plated diaphragm
SV
PTFE coated diaphragm for non-stick purposes
Special threads in lower housing
R9
Male lower housing threads
Complete the 3051SAL model number by specifying options as needed:
page 70
ERS transmitter options
page 80
Scalable level transmitter options
1.
Supplied with C4401 aramid fiber gasket if no other remote seal gasket material is selected.
2.
Flushing connection ring/lower housing assembly bolts provided as standard are carbon steel.
3.
Not available with Tantalum diaphragms (Material of Construction codes CC and DC).
100
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Hygienic Tri Clamp (SC) Seal

Good for use in hygienic applications

Easy installation on Tri-Clover style Tri Clamp connections (1.5-in. to 3-in.)

Conforms to 3-A® standard 74-03
Table 17. SC Hygienic Tri-Clover Style Tri Clamp Seal Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Process connection
SC(1)
★
Tri-Clover style Tri Clamp seal
Process connection size
3(2)(3)
11/2-in.
★
5(2)(4)
2-in.
★
7
3-in.
★
Maximum working pressure
0
★
1000 PSI
Isolating diaphragm material
Upper housing material
LA00
316L SST
316L SST
LB00
Alloy C-276
316L SST
★
Options (include with selected model number)
Remote seal diaphragm polishing
R6
Electropolishing
Remote seal diaphragm surface finish
RD
10 μin. (0.25 μm) Ra diaphragm surface finish
RG
15 μin. (0.375 μm) Ra diaphragm surface finish
RH
20 μin. (0.5 μm) Ra diaphragm surface finish
Surface finish certification(5)
Q16
Surface finish certification for hygienic remote seals
★
Complete the 3051SAL model number by specifying options as needed:
page 70
ERS Transmitter options
page 80
Scalable Level Transmitter options
1.
Clamp and gasket furnished by user. The maximum working pressure is dependent upon the clamp pressure rating.
2.
Consult factory for calibrated spans lower than 5 psi (345 mbar).
3.
1000 inH2O or 2490 mbar for 11/2-in. SC.
4.
150 inH2O or 373 mbar for 2-in. SC.
5.
Q16 is only available when the diaphragm seal has surface finish options (RD, RG, and RH).
Emerson.com/Rosemount
101
Rosemount 3051S Series
October 2017
Hygienic Tank Spud (SS) Seal

Commonly used in hygienic level applications

Seal diaphragm installed flush with inner tank wall

Conforms to 3-A standard 74-03
Table 18. SS Hygienic Tank Spud Seal Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Process connection
SS(1)
★
Hygienic Tank Spud Seal
Process connection size
A
★
4-in. Sch. 5 Tri Clamp
Maximum working pressure (clamp rating)
0
★
600 psi (41,37 bar)
Upper housing
A
★
316L SST
Diaphragm and wetted, extension material
Diaphragm and wetted
Extension
AL(2)
316L SST
316L SST
BB
Alloy C-276
316L SST
★
Extension length
2
2-in. (50 mm) extension
★
6
6-in. (150 mm) extension
★
Options (include with selected model number)
Remote seal diaphragm thickness
SC
0.006-in. (150 μm) diaphragm thickness
Tank spud included with shipment
S1
Tank spud included with shipment
★
Remote seal diaphragm polishing
R6
Electropolishing
Remote seal diaphragm surface finish
RH
20 μin. (0.5 μm) Ra diaphragm surface finish
RG(3)
15 μin. (0.375 μm) Ra diaphragm surface finish
Surface finish certification(4)
Q16
102
Surface finishing certification for hygienic remote seals
★
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Table 18. SS Hygienic Tank Spud Seal Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Complete the 3051SAL model number by specifying options as needed:
page 70
ERS Transmitter options
page 80
Scalable Level Transmitter options
1.
Clamp and Ethylene Propylene O-ring (conforms to 3-A standard 74 and USP Class VI) supplied.
2.
Diaphragm brazed and TIG-welded to extension.
3.
Require Option code R6 (Electropolishing).
4.
Q16 is only available when the diaphragm seal has surface finish options (RG and RH).
Emerson.com/Rosemount
103
Rosemount 3051S Series
October 2017
Specifications
Performance specifications
Conformance to specification (±3σ [Sigma])
For zero-based spans, reference conditions, silicone oil fill,
glass-filled PTFE O-rings, SST materials, coplanar flange
(3051SMV, 3051SAM, 3051S_C) or 1/2–14 NPT (3051S_T)
process connections, digital trim values set to equal range
points.
Technology leadership, advanced manufacturing techniques,
and statistical process control ensure pressure measurement
specification conformance to ±3σ or better.
Reference accuracy
Stated reference accuracy equations include terminal based
linearity, hysteresis, and repeatability.
For FOUNDATION Fieldbus and wireless devices, use calibrated
range in place of span.
Transmitter with coplanar sensor module (single variable)(1)
Differential pressure (3051S_CD, 3051SMV_ _ 3 or 4)
Gage pressure (3051S_CG, 3051SAM_ _G(2))
Ultra
Classic
Ultra for flow(3)
Ranges
2–4
±0.025% of span;
For spans less than 10:1,
±(0.005 + 0.0035[URL/Span])% of
span
±0.035% of span;
For spans less than 10:1,
±(0.015 + 0.005[URL/Span])% of
span
±0.04% of reading up to 8:1 DP
turndown from URL;
±(0.04 + 0.0023[URL/Reading])% of
reading to 200:1 DP turndown from
URL
Range 5
±0.05% of span;
For spans less than 10:1,
±(0.005 + 0.0045[URL/Span])% of
span
±0.065% of span;
For spans less than 10:1,
±(0.015 + 0.005[URL/Span])% of
span
N/A
Range 1
±0.10% of span;
±0.09% of span;
For spans less than 15:1,
For spans less than 15:1,
±(0.025 + 0.005[URL/Span])% of
±(0.015 + 0.005[URL/Span])% of span
span
N/A
Range 0
±0.09% of span;
For spans less than 2:1,
±0.045% of URL
N/A
±0.10% of span;
For spans less than 2:1,
±0.05% of URL
Absolute pressure (3051S_CA, 3051SAM_ _A(2))
Ultra
Classic
Ranges
1–4
±0.025% of span;
For spans less than 10:1,
±(.004[URL/Span])% of span
±0.035% of span;
For spans less than 10:1,
±(0.0065[URL/Span])% of span
Range 0
±0.075% of span;
For spans less than 5:1,
±(0.025 + 0.01[URL/Span])% of span
±0.075% of span;
For spans less than 5:1,
±(0.025 + 0.01[URL/Span])% of span
1.
For Rosemount 3051S assembled to Rosemount 1199 Remote Seals, use 3051SAL specifications.
2.
Specifications are for each gage/absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
3.
Ultra for Flow is only available for 3051S_CD ranges 2-3. For calibrated spans from 1:1 to 2:1 of URL, add ±0.005% of span analog output error.
104
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Transmitter with In-line sensor module(1)
Absolute pressure (3051S_TA, 3051SAM_ _E(2))
Gage pressure (3051S_TG, 3051SAM_ _T(2))
Ultra
Classic
Ranges 1– 4
±0.025% of span
For spans less than 10:1,
±(0.004[URL/Span])% of span
±0.035% of span
For spans less than 10:1,
±(0.0065[URL/Span])% of span
Range 5
±0.04% of span. For spans less than
10:1 ±0.004% of URL.
±0.065% of span.
For spans less than 10:1 ±0.0065% of URL
1.
For Rosemount 3051S assembled to Rosemount 1199 Remote Seals, use 3051SAL specifications.
2.
Specifications are for each gage/absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
Transmitter with multivariable sensor module(1)
Differential pressure and static pressure (3051SMV_ _1 or 2)
Classic MV
Ultra for flow(2)
DP Ranges 2–3
±0.04% of span
For spans less than 10:1,
±(0.01 + 0.004[URL/Span])% of span
±0.04% of reading up to 8:1 DP turndown from URL
±(0.04 + 0.0023[URL/Reading])% of reading to 200:1 DP turndown
from URL
DP Range 4
±0.055% of span
For spans less than 10:1,
±(0.015 + 0.005[URL/Span])% of span
±0.05% of reading up to 3:1 DP turndown from URL
±(0.05 + 0.0145[URL/RDG])% of reading to 100:1 DP turndown
from URL
DP Range 5
±0.065% of span
For spans less than 10:1,
±(0.015 + 0.005[URL/Span])% of span
N/A
DP Range 1
±0.10% of span
For spans less than 15:1,
±(0.025 + 0.005[URL/Span])% of span
N/A
AP and GP Ranges
3–4(3)
±0.055% of span
For spans less than 10:1,
±(0.0065[URL/Span])% of span
±0.025% of span
For spans less than 10:1,
±(0.004[URL/Span])% of span
1.
For Rosemount 3051S assembled to Rosemount 1199 Remote Seals, use 3051SAL specifications.
2.
Ultra for Flow is only available for Rosemount 3051SMV DP ranges 2-4. For calibrated DP spans from 1:1 to 2:1 of URL, add ±0.005% of span analog output error with
transmitter output code A.
3.
For DP range 1, 4 or 5, Classic MV and Ultra for Flow static pressure accuracy is ±0.055% of span on SP Range 4 only. For spans less than 5:1, ±(0.013[URL/Span])% of
span.
Process temperature RTD interface(1)
Liquid level transmitter
Process temperature (3051SMV_ _1 or 3)
3051SAL
±0.67 °F (0.37 °C)
Ultra
Classic
1.
Ranges
2–5
±0.055% of span
For spans less than
10:1,
±(0.015 +
0.005[URL/Span])
% of span
Emerson.com/Rosemount
±0.065% of span
For spans less than 10:1,
±(0.015 + 0.005[URL/Span])%
of span
Specifications for process temperature are for the transmitter portion only.
The transmitter is compatible with any Pt 100 (100 ohm platinum) RTD.
Examples of compatible RTDs include Rosemount series 68 and 78 RTD
Temperature Sensors.
105
Rosemount 3051S Series
October 2017
DP total accuracy for Enhanced ERS System performance(1)
3051SAM_ _G2, 3051SAM_ _G3, 3051SAM_ _T1, 3051SAM_ _T2, 3051SAM_ _G4, 3051SAM_ _T3,
3051SAL_ _G2 3051SAL_ _G3 3051SAL_ _T1 3051SAL_ _T2 3051SAL_ _G4 3051SAL_ _T3
250 inH2O
1000 inH2O
30 psi
150 psi
300 psi
800 psi
(622,1 mbar) (2488,4 mbar)
(2,1 bar)
(10,34 bar)
(20,7 bar)
(41,4 bar)
Sensor type
Rosemount 3051SAM(2)
0.2 inH2O
(0,5 mbar)
0.6 inH2O
(1,4 mbar)
0.9 inH2O
(2,2 mbar)
1.5 inH2O
(4,0 mbar)
6.2 inH2O
(15 mbar)
7.8 inH2O
(19 mbar)
2.2 inH2O
(5,5 mbar)
2.3 inH2O
(6,0 mbar)
3.0 inH2O
(7,5 mbar)
3.2 inH2O
(8,0 mbar)
6.5 inH2O
(16 mbar)
8.3 inH2O
(21 mbar)
Rosemount 3051SAL with
direct mount seal types
and sizes below(3):
• FF, FC, PF ≥
2-in./DN50
• EF ≥ 3-in./DN80
• All RT, RF, RC, SS
• SC ≥ 2.5-in.
Rosemount 3051SAL with
other seal types and sizes
1.
2.
3.
Consult Instrument Toolkit™ for performance.
Includes full ambient and temperature range from –40 to 85 °C (–40 to 185 °F) requires two transmitters with identical sensor ranges. Specification are only
applicable for spans down to 10:1.
For Rosemount 3051SAM assembled to a Rosemount 1199 Diaphragm Seal, use Rosemount 3051SAL specification for identical seal types and sizes.
For Rosemount 3051SAL with direct mount seals, specification applies to process temperatures from -45 to 205 °C and excludes diaphragm option code SC, 6-mil
diaphragm thickness.
DP reference accuracy of Rosemount 3051S ERS System(1)
2 coplanar gage transmitters (3051SAM_ _G)
Ultra
Classic
Ranges 2–4
±0.035% of DP span
±0.049% of DP span
Range 5
±0.071% of DP span
±0.092% of DP span
2 coplanar absolute transmitters (3051SAM_ _A)
Ranges 1–4
Ultra
Classic
±0.035% of DP span
±0.049% of DP span
2 In-line gage transmitters (3051SAM_ _T, 3051SAM_
_E)
Ranges 1–4
Ultra
Classic
±0.035% of DP span
±0.049% of DP span
2 Liquid level transmitters (3051SAL)
Ranges 1–4
1.
106
Ultra
Classic
±0.077% of DP span
±0.092% of DP span
Reference Accuracy specifications for ERS system assume that the
configuration contains two transmitters with identical sensor ranges, each
transmitter sensor is calibrated 0 – URL, and the DP Span = 10% of
transmitter URL.
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Transmitter total performance
Total performance is based on combined errors of reference accuracy, ambient temperature effect, and line pressure effect at normal
operating conditions (70% of span typical reading, 740 psi [51 bar] line pressure).
Models
3051S_CD
Ranges 2–3
3051S_CG
Ranges 2–5
3051S_CA
Ranges 2–4
3051S_T
Ranges 2–4
Ultra
Classic and classic MV
Ultra for flow(1)
±0.1% of span
±0.14% of span
±0.15% of reading
For ±50 °F (28 °C)
temperature changes,
0–100% relative humidity,
from 1:1 to 5:1 rangedown
For ±50 °F (28 °C) temperature
changes, 0-100% relative
humidity, over 8:1 DP
turndown from URL
3051SAM_ _A(3)
DP Ranges For ±50 °F (28 °C)
2–3 temperature changes;
0–100% relative humidity,
Ranges 2–5
from 1:1 to 5:1 rangedown
Ranges 2–4
3051SAM_ _T(3)
Ranges 2–4
3051SAM_ _E(3)
Ranges 2–4
3051SMV(2)
3051SAM_ _G(3)
Use Instrument Toolkit or the QZ Option to quantify the total performance of a remote seal
assembly under operating conditions.
3051SAL
1.
Ultra for Flow is only available for 3051S_CD Ranges 2–3 and 3051SMV DP Ranges 2–4.
2.
For Rosemount 3051SMV, Transmitter Total Performance specification applies to differential pressure measurement only.
3.
Specifications are for each gage/absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
Multivariable flow performance(1)
Mass, energy, actual volumetric, and totalized flow reference accuracy(2)
Ultra for flow
Classic MV(3)
DP Ranges 2–3
±0.65% of Flow Rate over a 14:1 flow range
(200:1 DP range)
±0.70% of Flow Rate over 8:1 flow range
(64:1 DP range)
DP Range 1
N/A
±0.90% of Flow Rate over 8:1 flow range
(64:1 DP range)
Models
3051SMV(4)
Annubar Flowmeter (3051SFA)
Ranges 2–3
±0.80% of flow rate at 14:1 flow turndown
±1.15% of flow rate at 8:1 flow turndown
Compact Annubar Flowmeter (3051SFC_A)
Ranges 2–3
Standard
±1.55% of flow rate at 14:1 flow turndown
±1.60% of flow rate at 8:1 flow turndown
Calibrated
±0.80% of flow rate at 14:1 flow turndown
±1.00% of flow rate at 8:1 flow turndown
Compact Conditioning Orifice Flowmeter (3051SFC_C)
Ranges 2–3
β = 0.4
±0.75% of flow rate at 14:1 flow turndown
±1.10% of flow rate at 8:1 flow turndown
β = 0.50, 0.65
±1.15% of flow rate at 14:1 flow turndown
±1.45% of flow rate at 8:1 flow turndown
Emerson.com/Rosemount
107
Rosemount 3051S Series
October 2017
Multivariable flow performance(1)
Mass, energy, actual volumetric, and totalized flow reference accuracy(2)
Models
Classic MV(3)
Ultra for flow
Compact Orifice Flowmeter(3051SFC_P)(5)
Ranges 2-3
β = 0.4
±1.30% of flow rate at 14:1 flow turndown
±1.45% of flow rate at 8:1 flow turndown
β = 0.50, 0.65
±1.30% of flow rate at 14:1 flow turndown
±1.45% of flow rate at 8:1 flow turndown
Integral Orifice Flowmeter (3051SFP)
Ranges 2–3
Bore < 0.160
±2.55% of flow rate at 14:1 flow turndown
±2.65% of flow rate at 8:1 flow turndown
0.160 ≤ Bore < 0.500
±1.55% of flow rate at 14:1 flow turndown
±1.70% of flow rate at 8:1 flow turndown
0.500 ≤ Bore ≤ 1.000
±1.05% of flow rate at 14:1 flow turndown
±1.25% of flow rate at 8:1 flow turndown
1.000 < Bore
±1.55% of flow rate at 14:1 flow turndown
±1.70% of flow rate at 8:1 flow turndown
1.
Flow performance specifications assume device is configured for full compensation of static pressure, process temperature, density, viscosity, gas expansion,
discharge coefficient, and thermal correction variances over the specified process operating range using multivariable type M or flowmeter measurement types 1
through 4.
2.
Energy, actual volumetric, and totalized flow not available with transmitter output code F.
3.
Differential pressure calibrated at up to 1/10th full scale for optimum flow accuracy/rangeability.
4.
Uncalibrated differential producer (0.2 < beta < 0.6 Orifice) installed per ASME MFC 3M or ISO 5167-1. Uncertainties for discharge coefficient, producer bore, tube
diameter, and gas expansion factor as defined in ASME MFC 3M or ISO 5167-1. Reference accuracy does not include RTD sensor accuracy.
5.
For line sizes less than 2-in. (50mm) or greater than 8-in. (200 mm), see the Rosemount DP Flowmeters and Primary Elements Product Data Sheet.
Uncompensated flow performance
Flow performance specifications assume the device only uses DP readings without pressure and temperature compensation.
Models
Ultra
Classic
Ultra for flow
±1.25% of flow rate at 8:1 flow
turndown
±0.80% of flow rate at 14:1 flow
turndown
Annubar Flowmeter (3051SFA)
Ranges 2–3
±0.95% of flow rate at 8:1 flow
turndown
Compact Conditioning Orifice Flowmeter (3051SFC_C)
Ranges 2–3
β = 0.4
±0.90% of flow rate at 8:1 flow
turndown
±1.10% of flow rate at 8:1 flow
turndown
±0.75% of flow rate at 14:1 flow
turndown
β = 0.50, 0.65
±1.25% of flow rate at 8:1 flow
turndown
±1.40% of flow rate at 8:1 flow
turndown
±1.15% of flow rate at 14:1 flow
turndown
Compact Annubar Flowmeter (3051SFC_A)
Ranges 2–3
Uncalibrated
±1.65% of flow rate at 8:1 flow
turndown
±1.70% of flow rate at 8:1 flow
turndown
±1.55% of flow rate at 14:1 flow
turndown
Calibrated
±0.95% of flow rate at 8:1 flow
turndown
±1.25% of flow rate at 8:1 flow
turndown
±0.80% of flow rate at 14:1 flow
turndown
108
Emerson.com/Rosemount
October 2017
Models
Rosemount 3051S Series
Ultra
Classic
Ultra for flow
Compact Orifice Flowmeter(3051SFC_P)(1)
Ranges 2–3
β = 0.4
±1.35% of flow rate at 8:1 flow
turndown
±1.80% of flow rate at 8:1 flow
turndown
±1.30% of flow rate at 14:1 flow
turndown
β = 0.50, 0.65
±1.35% of flow rate at 8:1 flow
turndown
±1.80% of flow rate at 8:1 flow
turndown
±1.30% of flow rate at 14:1 flow
turndown
Integral Orifice Flowmeter (3051SFP)
Ranges 2–3
Bore < 0.160
±2.65% of flow rate at 8:1 flow
turndown
±2.70% of flow rate at 8:1 flow
turndown
±2.60% of flow rate at 14:1 flow
turndown
0.160 ≤ Bore <
0.500
±1.70% of flow rate at 8:1 flow
turndown
±1.80% of flow rate at 8:1 flow
turndown
±1.60% of flow rate at 14:1 flow
turndown
0.500 ≤ Bore ≤
1.000
±1.25% of flow rate at 8:1 flow
turndown
±1.35% of flow rate at 8:1 flow
turndown
±1.15% of flow rate at 14:1 flow
turndown
1.000 < Bore
±1.70% of flow rate at 8:1 flow
turndown
±1.80% of flow rate at 8:1 flow
turndown
±1.60% of flow rate at 14:1 flow
turndown
1.
For line sizes less than 2-in. (50 mm) or greater than 8-in. (200 mm), see the Rosemount DP Flowmeters and Primary Elements Product Data Sheet.
Long term stability
Pressure
Ultra, Enhanced, and Ultra for
flow(1)
Models
3051S_CD
Ranges 2–5
3051S_CG
Ranges 2–5
3051S_CA
Ranges 1–4
3051S_T
Ranges 1–5
3051SAM_ _G(2)
Ranges 2–5
3051SAM_ _A(2)
Ranges 1–4
3051SAM_ _T(2)
Ranges 1–5
3051SAM_ _E(2)
Ranges 1–5
3051SMV_ _3,4
Ranges 2–5
3051SF_ _D,3,4
Ranges 2–5
3051SMV_ _1,2
DP Ranges 2–5
3051SF_1,2
AP and GP Ranges
3–4
Classic and Classic MV
±0.15% of URL for 15 years;
±0.20% of URL for 15 years;
for ±50 °F (28 °C) temperature changes, for ±50 °F (28 °C) temperature changes, up to
up to 1000 psi (68,95 bar) line pressure 1000 psi (68,95 bar) line pressure
±0.15% of URL for 15 years;
for ±50 °F (28 °C) temperature changes,
up to 1000 psi (68,95 bar)
line pressure
±0.20% of URL for 15 years; for
±50 °F (28 °C) temperature changes, up to
1000 psi (68,95 bar) line pressure
1.
Ultra is only available for 3051S, 3051SMV_ _3 and 4, 3051SF_3, 4, 7, and D. Ultra for Flow is only available on 3051S_CD ranges 2–3, 3051SMV DP ranges 2–4, and
3051SF DP ranges 2–3.
2.
Specifications are for each gage/absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
Emerson.com/Rosemount
109
Rosemount 3051S Series
October 2017
Process temperature(1)
Models
3051SMV
RTD Interface
3051SF
1.
The greater of ±0.185 °F (0.103 °C) or 0.1% of reading per 5 years (excludes RTD sensor stability).
Specifications for process temperature are for the transmitter portion only. The transmitter is compatible with any Pt 100 (100 ohm platinum) RTD. Examples of
compatible RTDs include the Rosemount Series 68 and 78 RTD Temperature Sensors.
Warranty(1)
Models
Ultra, Enhanced, and Ultra
Classic and Classic MV(3)
for flow(2)
Optional extended warranty(4)
All Rosemount 3051S
Products
15-year limited warranty
WR5: 5-year limited warranty
WR3: 3-year limited warranty
1-year limited warranty
1.
Warranty details can be found in Emerson Terms and Conditions of Sale, Document 63445, Rev G (10/06).
2.
Rosemount Ultra and Ultra for Flow transmitters have a limited warranty of 15 years from date of shipment. All other provisions of Emerson standard limited
warranty remain the same.
3.
Goods are warranted for 12 months from the date of initial installation or 18 months from the date of shipment by seller, whichever period expires first.
4.
Rosemount extended warranties have a limited warranty of five or three years from date of shipment.
Dynamic performance
Total time response at 75 °F (24 °C), includes dead time(1)(2)
3051S_C
3051SF_D
DP Ranges 2–5: 100 ms
Range 1: 255 ms
Range 0: 700 ms
3051S_T
3051SMV_ _1 or 2
3051SF_1, 2, 5, or 6
3051SMV_ _3 or 4
3051SF_3, 4, or 7
ERS System
(3051SAM)
100 ms
DP Range 1: 310 ms
DP Range 2: 170 ms
DP Range 3: 155 ms
AP and GP: 240 ms
DP Ranges 2–5: 145 ms
DP Range 1: 300 ms
DP Range 0: 745 ms
360 ms
1.
For FOUNDATION Fieldbus (output code F), add 52 ms to stated values (not including segment macro-cycle).
For option code DA2, add 45 ms (nominal) to stated values.
2.
Consult Instrument Toolkit for transmitter configurations with remote seals including 3051SAL.
Dead time(1)
3051S_C
3051S_T
3051SF_D
3051SAL_C
3051SMV
3051SF_1-7
ERS system (includes 3051SAM, 3051SAL_P, and 3051SAL_S
models)
45 ms (nominal)
DP: 100 ms
AP and GP: 140 ms
RTD Interface: 1 s
220 ms
1.
110
For option code DA2, dead time is 90 milliseconds (nominal).
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Sensor update rate(1)
ERS System
(includes 3051SAM,
3051SAL_P, and
3051SAL_S models)
3051S_C or T
3051SF_D
3051SAL_C
3051SMV
3051SF_1-7
22 updates per
second
DP: 22 updates per sec.
AP and GP: 11 updates per second
RTD Interface: 1 update per second
Calculated variables(2):
Mass/volumetric flow rate: 22 updates per second 11 updates per
Energy flow rate: 22 updates per second
seconds
Totalized flow: 1 update per second
1.
Does not apply to Wireless (output code X). See “IEC 62591 (WirelessHART)” on page 120 for wireless update rate.
2.
Energy, Volumetric, and Totalized flow not available with transmitter output code F.
Ambient temperature effect
Transmitter with coplanar sensor module (single variable)
Differential pressure: (3051S_CD, 3051SMV_ _3 or 4)
Gage pressure: (3051S_CG, 3051SAM_ _G(1))
Ultra
per 50 °F (28 °C)
Classic
per 50 °F (28 °C)
Ultra for flow(2)
-40 to 185 °F (-40 to 85 °C)
Ranges 2–5(3)
±(0.009% URL + 0.025% span)
from 1:1 to 10:1;
±(0.018% URL + 0.08% span)
from >10:1 to 200:1
±(0.0125% URL +0.0625% span)
from 1:1 to 5:1;
±(0.025% URL + 0.125% span)
from >5:1 to 150:1
±0.13% of reading up to 8:1 DP turndown
from URL;
±(0.13 + 0.0187[URL/Reading])% of
reading to 100:1 DP turndown from URL
Range 0
±(0.25% URL + 0.05% span)
from 1:1 to 30:1
±(0.25% URL + 0.05% span)
from 1:1 to 30:1
N/A
Range 1
±(0.1% URL + 0.25% span)
from 1:1 to 50:1
±(0.1% URL + 0.25% span)
from 1:1 to 50:1
N/A
Absolute pressure: (3051S_CA, 3051SAM_ _A(1))
Ultra
per 50 °F (28 °C)
Classic
per 50 °F (28 °C)
Ranges 2–4
±(0.0125% URL + 0.0625% span)
from 1:1 to 5:1;
±(0.025% URL + 0.125% span)
from >5:1 to 200:1
±(0.0125% URL + 0.0625% span)
from 1:1 to 5:1;
±(0.025% URL + 0.125% span)
from >5:1 to 150:1
Range 0
±(0.1% URL + 0.25% span)
from 1:1 to 30:1
±(0.1% URL + 0.25% span)
from 1:1 to 30:1
Range 1
±(0.0125% URL + 0.0625% span)
from 1:1 to 5:1;
±(0.025% URL + 0.125% span)
from >5:1 to 100:1
±(0.0125% URL + 0.0625% span)
from 1:1 to 5:1;
±(0.025% URL + 0.125% span)
from >5:1 to 100:1
1.
Specifications are for each gage/absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
2.
Ultra for Flow is only available for 3051S_CD Ranges 2–3 and 3051SMV DP Ranges 2–3.
3.
Use Classic specification for 3051SMV DP Range 5 Ultra and 3051S_CD Range 5 Ultra.
Emerson.com/Rosemount
111
Rosemount 3051S Series
October 2017
Transmitter with In-line sensor module
Absolute pressure: (3051S_TA, 3051SAM_ _E(1))
Gage pressure: (3051S_TG, 3051SAM_ _T(1))
Ultra
per 50 °F (28 °C)
Classic
per 50 °F (28 °C)
Ranges 2–4
±(0.009% URL + 0.025% span) from 1:1 to 10:1;
±(0.018% URL + 0.08% span) from >10:1 to 200:1
±(0.0125% URL + 0.0625% span) from 1:1 to 5:1;
±(0.025% URL + 0.125% span) from >5:1 to 150:1
Range 5
±(0.05% URL + 0.075% span) from 1:1 to 10:1
±(0.05% URL + 0.075% span) from 1:1 to 10:1
Range 1
±(0.0125% URL + 0.0625% span) from 1:1 to 5:1;
±(0.025% URL + 0.125% span) from >5:1 to 100:1
±(0.0125% URL + 0.0625% span) from 1:1 to 5:1;
±(0.025% URL + 0.125% span) from >5:1 to 100:1
1.
Specifications are for each gage/absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
Transmitter with multivariable sensor module
Differential pressure and static pressure (3051SMV_ _1 or 2)
Models
Classic MV
Per 50 °F (28 °C)
Ultra for flow
-40 to 185 °F (-40 to 85 °C)
DP Ranges 2–3
±(0.0125% URL + 0.0625% span) from 1:1 to 5:1;
±(0.025% URL + 0.125% span) for >5:1 to 100:1
±0.13 reading up to 8:1 DP turndown from URL;
±(0.13 + 0.0187[URL/Reading])% reading to 100:1 DP
turndown from URL
DP Range 4
±(0.025% URL + 0.125% span) from 1:1 to 30:1
±(0.035% URL + 0.125% span) from 30:1 to 100:1
±0.130% of reading less than or equal to 3:1
±(0.050 + 0.065 [URL/RDG])% of reading greater than 3:1
DP Range 5
±(0.025% URL + 0.125% span) from 1:1 to 30:1
±(0.035% URL + 0.125% span) from 30:1 to 100:1
N/A
DP Range 1
±(0.1% URL + 0.25% span)
from 1:1 to 50:1
Not available
AP and GP
±(0.0125% URL + 0.0625% span) from 1:1 to 10:1;
±(0.025% URL + 0.125% span) for >10:1 to 100:1
±(0.009% URL + 0.025% span) from 1:1 to 10:1;
±(0.018% URL + 0.08% span) for >10:1(1)
1.
For DP range 4 or 5, Ultra for Flow ambient temperature effect on static pressure is ±(0.0125% URL + 0.0625% Span) from 1:1 to 10:1; ±(0.025% URL + 0.125% Span)
for >10:1.
Liquid level transmitter
Process temperature RTD interface(1)
3051SAL
Ultra
Classic
See Instrument Toolkit.
See Instrument Toolkit.
Process temperature
(3051SMV_ _1 or 3)
Classic MV
Per 50 °F (28 °C)
Ultra for flow
-40 to 185 °F (-40 to 85 °C)
±0.39 °F (0,216 °C) per 50 °F
(28 °C)
±0.39 °F (0,216 °C) per 50 °F
(28 °C)
1.
112
Specifications for process temperature are for the transmitter portion only.
The transmitter is compatible with any Pt 100 (100 ohm platinum) RTD.
Examples of compatible RTDs include Rosemount series 68 and 78 RTD
Temperature Sensors.
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Line pressure effect
3051S_CD
3051SMV (DP measurement
only)
Ultra and Ultra for flow
Classic and classic MV
Range 2–3
± 0.025% URL per 1000 psi (68,95 bar)
± 0.05% URL per 1000 psi (68,95 bar)
Range 0
± 0.125% URL per 100 psi (6,89 bar)
± 0.125% URL per 100 psi (6,89 bar)
Range 1
± 0.25% URL per 1000 psi (68,95 bar)
± 0.25% URL per 1000 psi (68,95 bar)
Range 2–3
± 0.1% of reading per 1000 psi (68,95 bar)
± 0.1% of reading per 1000 psi (68,95 bar)
Range 0
± 0.15% of reading per 100 psi (6,89 bar)
± 0.15% of reading per 100 psi (6,89 bar)
Range 1
± 0.4% of reading per 1000 psi (68,95 bar)
± 0.4% of reading per 1000 psi (68,95 bar)
Zero error(1)
Span error(2)
1.
Zero error can be removed by performing a zero trim at line pressure.
2.
Specifications for option code P0 are 2 times those shown above.
Mounting position effects
Models
Ultra, Ultra for flow, classic and classic MV
3051S_CD or CG
3051SMV_ _ 3 or 4
3051SF_3, 4, 7, or D
3051SAM_ _G
Zero shifts up to ±1.25 inH2O (3,11 mbar), which can be zeroed
Span: no effect
3051S_CA
3051S_T
3051SAM_ _A, T, or E
Zero shifts to ±2.5 inH2O (6,22 mbar), which can be zeroed
Span: no effect
3051SMV_ _ 1 or 2 DP Sensor
3051SF_1, 2, 5, or
GP/AP
6
Sensor
3051SAL
Zero shifts up to ±1.25 inH2O (3,11 mbar), which can be zeroed
Span: no effect
Zero shifts to ±2.5 inH2O (6,22 mbar), which can be zeroed
Span: no effect
With liquid level diaphragm in vertical plane, zero shift of up to ±1 inH2O (2,49 mbar). With
diaphragm in vertical plane, zero shift of up to ±5 inH2O (12,43 mbar) plus extension length on
extended units. All zero shifts can be zeroed.
Span: no effect
Vibration effect
Power supply effect
Less than ±0.1% of URL when tested per the requirements of
IEC60770-1 field or pipeline with high vibration level
(10–60 Hz 0.21 mm displacement peak amplitude/60–2000 Hz
3g).
Less than ±0.005% of calibrated span per volt change in voltage
at the transmitter terminals
For Housing Style codes 1J, 1K, 1L, 2J, and 2M:
Less than ±0.1% of URL when tested per the requirements of
IEC60770-1 field with general application or pipeline with low
vibration level (10–60 Hz 0.15 mm displacement peak
amplitude/60–500 Hz 2g).
Emerson.com/Rosemount
113
Rosemount 3051S Series
October 2017
Transient protection (option T1)
Electromagnetic compatibility (EMC)
Meets all industrial environment requirements of EN61326 and
NAMUR NE-21(1)(2). Maximum deviation < 1% Span during EMC
disturbance(3)(4)(5).
1.
NAMUR NE-21 is met on Rosemount 3051SMV output type A if no external
temperature sensor is attached.
2.
NAMUR NE-21 does not apply to wireless output code X or ERS
configurations.
3.
During surge event device may exceed maximum EMC deviation limit or
reset; however, device will self-recover and return to normal operation
within specified start-up time.
4.
For devices with Junction Box housing or Remote Display (housing styles:
2A-2C, 2E-2G, 2J, 2M) testing performed with shielded cable.
5.
Rosemount 3051SMV Measurement Type 1, 3, 5, 6 and Rosemount 3051SF
Measurement Type 1, 3, 5, 7 require shielded cable for the process
temperature connection.
Tested in accordance with IEEE C62.41.2-2002, Location
Category B

6 kV crest (0.5 μs – 100 kHz)

3 kA crest (8 ⫻ 20 microseconds)

6 kV crest (1.2 ⫻ 50 microseconds)
Functional specifications
Range and sensor limits
Transmitter with coplanar sensor module (single variable)
DP Sensor(1)
(3051S_CD, 3051SMV_ _3, 4, or D
Range 3051SF_3, 4, or 7, 3051SAL_CD)
AP Sensor(2)
(3051S_CA, 3051SAM_ _A,
3051SAL_ _A)
GP Sensor
(3051S_CG, 3051SAM_ _G,
3051SAL_ _G)
Lower (LRL)(3)
Upper (URL)
Lower (LRL)(4)
Upper (URL)
Lower (LRL)
Upper (URL)
0
–3.00 inH2O
(–7,46 mbar)
3.00 inH2O
(7,46 mbar)
N/A
N/A
0 psia
(0 bar)
5.00 psia
(0,34 bar)
1
–25.00 inH2O
(–62,16 mbar)
25.00 inH2O
(62,16 mbar)
–25.00 inH2O
(–62,16 mbar)
25.00 inH2O
(62,16 mbar)
0 psia
(0 bar)
30.00 psia
(2,07 bar)
2
–250.00 inH2O
(–621,60 mbar)
250.00 inH2O
(621,60 mbar)
–250.00 inH2O
(–621,60 mbar)
250.00 inH2O
(621,60 mbar)
0 psia
(0 bar)
150.00 psia
(10,34 bar)
3
–1000.00 inH2O
(–2,49 bar)
1000.00 inH2O
(2,49 bar)
–14.2 psig
(–979 mbar)
1000.00 inH2O
(2,49 bar)
0 psia
(0 bar)
800.00 psia
(55,16 bar)
4
–300.00 psi
(–20,68 bar)
300.00 psi
(20,68 bar)
–14.2 psig
(–979 mbar)
300.00 psi
(20,68 bar)
0 psia
(0 bar)
4000.00 psia
(275,79 bar)
5
–2000.00 psi
(–137,90 bar)
2000.00 psi
(137,90 bar)
–14.2 psig
(–979 mbar)
2000.00 psi
(137,90 bar)
N/A
N/A
1.
Rosemount 3051SF Flowmeters only available with ranges 1, 2, and 3.
2.
Range 0 is not available for 3051SAL_ _A.
3.
The Lower Range Limit (LRL) is 0 inH2O (0 mbar) for Ultra for Flow Performance Class and Rosemount 3051SF Flowmeters.
4.
Assumes atmospheric pressure of 14.7 psia (1 bar).
114
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Transmitter with in-line sensor module
Range
GP Sensor
(3051S_TG, 3051SAM_ _T, 3051SAL_ _T)
AP Sensor
(3051S_TA, 3051SAM_ _E, 3051SAL_ _E)
Lower (LRL)(1)
Upper (URL)
Lower (LRL)
Upper (URL)
1
–14.70 psig (–1,01 bar)
30.00 psig (2,07 bar)
0 psia (0 bar)
30.00 psia (2,07 bar)
2
–14.70 psig (–1,01 bar)
150.00 psig (10,34 bar)
0 psia (0 bar)
150.00 psia (10,34 bar)
3
–14.70 psig (–1,01 bar)
800.00 psig (55,16 bar)
0 psia (0 bar)
800.00psia (55,16 bar)
4
–14.70 psig (–1,01 bar)
4000.00 psig (275,79 bar)
0 psia (0 bar)
4000.00 psia (275,79 bar)
5
–14.70 psig (–1,01 bar)
10000.00 psig (689,48 bar)
0 psia (0 bar)
10000.00 psia (689,48 bar)
1.
Assumes atmospheric pressure of 14.7 psia (1 bar-a).
Transmitter with multivariable sensor module
(3051SMV_ _1, 3051SMV_ _2, 3051SF_1, 3051SF_2, 3051SF_5, and 3051SF_6)
DP Sensor
Range
Lower (LRL)(1)
Upper (URL)
1
–25.00 inH2O (–62,16 mbar)
25.00 inH2O (62,16 mbar)
2
–250.00 inH2O (–621,60 mbar)
250.00 inH2O (621,60 mbar)
3
–1000.00 inH2O (–2,48 bar)
1000.00 inH2O (2,48 bar)
4
–150.00 psi (–10,34 bar)
150.00 psi (10,34 bar)
5
–2000.00 psi (137,89 bar)
2000.00 psi (137,89 bar)
1.
Lower (LRL) is 0 inH2O (0 mbar) for Ultra for Flow and Rosemount 3051SF_ Flowmeters.
Static pressure sensor (GP/AP)
Range
1.
Lower (LRL)
Upper (URL)(1)
3
GP(2)(3): –14.20 psig (–0,97 bar)
AP: 0.50 psia (34,47 mbar)
GP: 800.00 psig (55,15 bar)
AP: 800.00 psia (55,15 bar)
4
GP(2)(3): –14.20 psig (–0,97 bar)
AP: 0.50 psia (34,47 mbar)
GP: 3626.00 psig (250,00 bar)
AP: 3626.00 psia (250,00 bar)
For SP Range 4 with DP Range 1, the URL is 2000 psi (137,9 bar).
2.
Inert fill: minimum pressure = 1.5 psia (0,10 bar) or –13.2 psig (–0,91 bar).
3.
Assumes atmospheric pressure of 14.7 psia (1 bar-a).
Process temperature RTD Interface
(3051SMV_ _1 or 3, 3051SF_1, 3, 5 or 7)(1)
1.
Lower (LRL)
Upper (URL)
–328 °F (–200 °C)
1562 °F (850 °C)
Transmitter is compatible with any Pt 100 RTD sensor. Examples of compatible RTDs include Rosemount Series 68 and 78 RTD Temperature Sensors.
Emerson.com/Rosemount
115
Rosemount 3051S Series
October 2017
Minimum span limits
Transmitter with coplanar sensor module (single variable)
DP Sensor(1)
GP Sensor
(3051S_CG, 3051SAM_ _G(3),
(3051S_CD, 3051SMV_ _3 or 4,
(2)
3051SAL_ _G(2)(3))
Range 3051SF_D, 3, 4 or 7, 3051SAL_ _CD )
AP Sensor
(3051S_CA, 3051SAM_ _A(3),
3051SAL_ _A(2)(3))
Ultra and
Ultra for Flow
Classic
Ultra
Classic
Ultra
Classic
0
0.10 inH2O
(0,25 mbar)
0.10 inH2O
(0,25 mbar)
N/A
N/A
0.167 psia
(11,49 mbar)
0.167 psia
(11,49 mbar)
1
0.50 inH2O
(1,24 mbar)
0.50 inH2O
(1,24 mbar)
0.50 inH2O
(1,24 mbar)
0.50 inH2O
(1,24 mbar)
0.30 psia
(20,68 mbar)
0.30 psia
(20,68 mbar)
2
1.25 inH2O
(3,11 mbar)
1.67 inH2O
(4,14 mbar)
1.25 inH2O
(3,11 mbar)
1.67 inH2O
(4,14 mbar)
0.75 psia
(51,71 mbar)
1.00 psia
(68,95 mbar)
3
5.00 inH2O
(12,43 mbar)
6.67 inH2O
(16,58 mbar)
5.00 inH2O
(12,43 mbar)
6.67 inH2O
(16,58 mbar)
4.00 psia
(275,79 mbar)
5.33 psia
(367,72 mbar)
4
1.50 psi
(103,42 mbar)
2.00 psi
(137,90 mbar)
1.50 psig
(103,42 mbar)
2.00 psig
(137,90 mbar)
20.00 psia
(1,38 bar)
26.67 psia
(1,84 bar)
5
10.00 psi
(689,48 mbar)
13.33 psi
(919,30 mbar)
10.00 psig
(689,48 mbar)
13.33 psig
(919,30 mbar)
N/A
N/A
1.
Rosemount 3051SF flowmeters only available with ranges 1, 2, and 3.
2.
For Rosemount 3051SAL models, use Classic minimum span limits.
3.
Specifications are for each gage/absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
Transmitter with in-line sensor module
Range
GP Sensor
(3051S_TG, 3051SAM_ _T(1), 3051SAL_ _T(2))
AP Sensor
(3051S_TA, 3051SAM_ _E(1), 3051SAL_ _E(2))
Ultra
Classic
Ultra
Classic
1
0.30 psig (20,68 mbar)
0.30 psig (20,68 mbar)
0.30 psia (20,68 mbar)
0.30 psia (20,68 mbar)
2
0.75 psig (51,71 mbar)
1.00 psig (68,95 mbar)
0.75 psia (51,71 mbar)
1.00 psia (68,95 mbar)
3
4.00 psig (275,79 mbar)
5.33 psig (367,72 mbar)
4.00 psia (275,79 mbar)
5.33 psia (367,72 mbar)
4
20.00 psig (1,38 bar)
26.67 psig (1,84 bar)
20.00 psia (1,38 bar)
26.67 psia (1,84 bar)
5
1000.00 psig (68,95 bar)
2000.00 psig (137,90 bar)
1000.00 psia (68,95 bar)
2000.00 psia (137,90 bar)
1.
Specifications are for each gage/absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
2.
For Rosemount 3051SAL models, use Classic minimum span limits.
116
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Transmitter with multivariable sensor module
(3051SMV_ _1 or 2, 3051SF_1, 2, 5, or 6)
DP span considerations for electronic remote sensor
applications
Ultra for Flow
Classic MV
1
N/A
0.5 inH2O (1,24 mbar)
It is recommended that the DP rangedown (operating
pressure/DP span) for ERS applications not exceed 100:1.
Consult with Emerson sales representative when considering a
Rosemount 3051S ERS System for applications beyond 100:1
rangedown.
2
1.3 inH2O (3,23 mbar)
2.5 inH2O (6,22 mbar)
Service
3
5.0 inH2O (12,43 mbar)
10.0 inH2O (24,86 mbar)
4
1.5 psi (103,42 mbar)
3.0 psi (206,84 mbar)
5
N/A
20.0 psi (1,38 bar)
DP Sensor
Range
Rosemount 3051S, 3051SMV_P, 3051SAM, and 3051SF_5, 6,
7, or D (direct process variable output):
Liquid, gas, and vapor applications
Static pressure sensor (GP/AP)
Rosemount 3051SAL
Range
Ultra for Flow
Classic MV
3
4.0 psi (275,79 mbar)
8.0 psi (551,58 mbar)
4
18.13 psi (1,25 bar)
36.26 psi (2,50 bar)
Liquid level applications
Rosemount 3051SMV_M and 3051SF_1, 2, 3, or 4 (mass and
energy flow output)(1):
Some fluid types are only supported by certain measurement
types.
Process temperature RTD Interface
(3051SMV_ _1 or 3, 3051SF_1, 3, 5 or 7)
1.
Minimum span = 50 °F (28 °C)
For option code A: 4-20mA HART only.
Table 19. Fluid Compatibility with Pressure and Temperature Compensation
• Available
Ordering
code
— Not available
Fluid types
Measurement type
Liquids
Saturated steam Superheated steam Gas and natural gas
1
DP/P/T (full compensation)
•
•
•
•
2
DP/P
•
•
•
•
3
DP/T
•
•
—
—
4
DP only
•
•
—
—
Emerson.com/Rosemount
117
Rosemount 3051S Series
4–20 mA HART
October 2017
Figure 3. Rosemount 3051S ERS System
Zero and span adjustment
Zero and span values can be set anywhere within the range.
Span must be greater than or equal to the minimum span.
If supply voltage ≤ 16.74 Vdc:
Maximum Loop Resistance = 277 ⫻ (Power Supply Voltage – 16.0)
If supply voltage > 16.74 Vdc:
Maximum Loop Resistance = 43.5 ⫻ (Power Supply Voltage – 12.0)
Output
Power supply
Load limitations
Maximum loop resistance is determined by the voltage level of
the external power supply, as described by:
Figure 1. Rosemount 3051S and 3051SF_D
Maximum Loop Resistance = 43.5 ⫻ (Power Supply Voltage – 10.5)
Load (Ohms)
Operating
Region
206
0
External power supply required.
 Rosemount 3051S and 3051SF_D:
10.5 to 42.4 Vdc with no load
 Rosemount 3051S and 3051SF_D with Advanced HART
Diagnostics Suite: 12 to 42.4 Vdc with no load
 Rosemount 3051SMV and 3051SF_1-7:
12 to 42.4 Vdc with no load
 Rosemount 3051S ERS System:
16.0 to 42.4 Vdc with no load
16 16.74
42.4
Voltage (Vdc)
The Field Communicator requires a minimum loop resistance of 250 Ω
for communication.
Selectable HART revisions (option code HR7)
The 2-wire 4–20 mA is user-selectable for linear or square root
output. Digital process variable superimposed on 4–20 mA
signal is available to any host that conforms to HART protocol.
The Rosemount 3051S with Advanced HART Diagnostics (DA2)
comes with Selectable HART revisions. Digital communications
based on HART Revision 7 (with option code HR7 selected) or
Revision 5 (default) protocol can be selected. The HART revision
can be switched in the field using any HART-based
configuration. See the Rosemount 3051S Reference Manual for
instructions on how to switch HART revision.
1387
Advanced HART diagnostics suite (option code DA2)
1000
Statistical Process Monitoring (SPM) provides statistical data
(standard deviation, mean, coefficient of variation) that can be
used to detect process and process equipment anomalies,
including plugged impulse lines, air entrainment, pump
cavitation, furnace flame instability, distillation column flooding
and more. This diagnostic allows you to take preventative
measures before abnormal process situations result in
unscheduled downtime or rework.
500
Operating
Region
0
10.5
20
30
42.4
Voltage (Vdc)
The Field Communicator requires a minimum loop resistance of 250 Ω
for communication.
Figure 2. Rosemount 3051SMV and 3051SF_1-7, 3051S and
3051SF_D with HART Diagnostics (option code
DA2)
Maximum Loop Resistance = 43.5 ⫻ (Power Supply Voltage – 12.0)
1322
Load (Ohms)
Load (Ohms)
1322
The 2-wire 4–20 mA is user-selectable for linear or square root
output. Digital process variable superimposed on 4–20 mA
signal is available to any host that conforms to the HART
protocol.
1000
500
Operating
region
0
Power Advisory diagnostic pro-actively detects and notifies you
of degraded electrical loop integrity before it can affect your
process operation. Example loop problems that can be detected
include water in the terminal compartment, corrosion of
terminals, improper grounding, and unstable power supplies.
The Device Dashboard presents the diagnostics in a graphical,
task-based interface that provides single click access to critical
process/device information and descriptive graphical
troubleshooting.
Suite includes: SPM, Power Advisory, Status Log, Variable Log,
Advanced Process Alerts, Service Alerts, and Time Stamp
capability.
12.0
20
30
42.4
Voltage (Vdc)
The Field Communicator requires a minimum loop resistance of 250 Ω
for communication.
118
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
FOUNDATION Fieldbus
Advanced control function block suite (option code A01)
Input selector block
Power supply
Selects between inputs and generates an output using
specific selection strategies such as minimum, maximum,
midpoint, average, or first “good.”
External power supply required; transmitters operate on
9.0–32.0 Vdc (9.0–17.5 Vdc for FISCO) transmitter terminal
voltage.
Arithmetic block
Current draw
Provides pre-defined application-based equations including
flow with partial density compensation, electronic remote
sensors, hydrostatic tank gauging, ratio control and others.
17.5 mA for all configurations (including LCD display option)
FOUNDATION Fieldbus parameters
Signal characterizer block
Schedule Entries
22 (max.)
Links
25 (max.)
Characterizes or approximates any function that defines an
input/output relationship by configuring up to twenty X, Y
coordinates. The block interpolates an output value for a
given input value using the curve defined by the configured
coordinates.
Virtual Communications Relationships (VCR) 20 (max.)
Standard function blocks
Integrator block
Resource block
Compares the integrated or accumulated value from one or
two variables to pre-trip and trip limits and generates
discrete output signals when the limits are reached. This
block is useful for calculating total flow, total mass, or
volume over time.
Contains hardware, electronics, and diagnostic information.
Transducer block
Contains actual sensor measurement data including the
sensor diagnostics and the ability to trim the pressure sensor
or recall factory defaults.
Output splitter block
Splits the output of one PID or other control block so that the
PID will control two valves or other actuators.
LCD display block
Configures the local display.
Control selector block
Analog input blocks
Selects one of up to three inputs (highest, middle, or lowest)
that are normally connected to the outputs of PID or other
control function blocks.
Processes the measurements for input into other function
blocks. The output value is in engineering or custom units
and contains a status indicating measurement quality.
PID block with auto-tune
Block
Execution time
Contains all logic to perform PID control in the field
including cascade and feedforward. Auto-tune capability
allows for superior tuning for optimized control
performance.
Resource
N/A
Transducer
N/A
LCD Display Block
N/A
Analog Input 1
20 milliseconds
PID with Auto-tune
35 milliseconds
Input Selector
20 milliseconds
Arithmetic
20 milliseconds
Signal Characterizer
20 milliseconds
Integrator
20 milliseconds
Output Splitter
20 milliseconds
Control Selector
20 milliseconds
Backup Link Active Scheduler (LAS)
The transmitter can function as a Link Active Scheduler if the
current link master device fails or is removed from the segment.
Software upgrade in the Field
Software for the Rosemount 3051S with FOUNDATION Fieldbus is
easy to upgrade in the field using the FOUNDATION Fieldbus
Common Device Software Download procedure.
Plantweb alerts
Enable the full power of the Plantweb digital architecture by
diagnosing instrumentation issues, communicating advisory,
maintenance, and failure details, and recommending a solution.
Fully compensated mass flow block (option code H01)(1)
Calculates fully compensated mass flow based on differential
pressure with external process pressure and temperature
measurements over the Fieldbus segment. Configuration for the
mass flow calculation is easily accomplished using the
Rosemount Engineering Assistant 5.5.1 software.
1.
Emerson.com/Rosemount
Only applies to 3051S with transmitter output code F.
119
Rosemount 3051S Series
October 2017
FOUNDATION Fieldbus diagnostics suite (option code D01)(1)
Power module
Statistical Process Monitoring (SPM) provides statistical data
(standard deviation and mean) that can be used to detect
process and process equipment anomalies, including plugged
impulse lines, air entrainment, pump cavitation, furnace flame
instability, distillation column flooding, and more. This
diagnostic allows you to take preventative measures before
abnormal process situations result in unscheduled downtime or
rework.
Field replaceable, keyed connection eliminates the risk of
incorrect installation, Intrinsically Safe Lithium-thionyl chloride
Power Module with polybutadine terephthalate (PBT)
enclosure. Ten-year life at one minute update rate.(1)(2)
The Device Dashboard presents the diagnostics in a graphical,
task-based interface that provides single click access to critical
process/device information and descriptive graphical
troubleshooting.
Suite includes: Statistical Process Monitoring (SPM) and Plugged
Impulse Line Detection (PIL).
1.
Reference conditions are 70 °F (21 °C), and routing data for three additional
network devices.
Note: Continuous exposure to ambient temperature limits of -40 °F or 185
°F (-40 °C or 85 °C) may reduce specified life by less than 20 percent.
2.
6.5-year life at one minute update rates when used with 3051SMV.
Overpressure limits
Transmitters withstand the following limits without damage:
Coplanar sensor module (single variable)
DP(1) and GP
AP
3051S_CA
3051SAM_ _A
Range
IEC 62591 (WirelessHART)
3051S_CD, 3051S_CG
3051SMV_ _3 or 4
3051SF_3, 4, 7, or D
3051SAM_ _G
External antenna (WK option):
Maximum of 10 mW (10 dBm) EIRP
0
750 psi (51,71 bar)
60 psia (4,14 bar)
1
2000 psi (137,90 bar)
750 psia (51,71 bar)
Extended range, external antenna (WM option):
Maximum of 18 mW (12.5 dBm) EIRP
2
3626 psi (250,00 bar)
1500 psia (103,42 bar)
Remote (WJ option) antenna:
Maximum of 17 mW (12.3 dBm) EIRP
3
3626 psi (250,00 bar)
1600 psia (110,32 bar)
4
3626 psi (250,00 bar)
6000 psia (413,69 bar)
High-gain, remote antenna (WN option):
Maximum of 40 mW (16 dBm) EIRP
5
3626 psi (250,00 bar)
N/A
Output
IEC 62591 (WirelessHART), 2.4 GHz DSSS
Radio frequency power output from antenna
Local display
The optional seven-digit LCD display can display user-selectable
information such as primary variable in engineering units,
percent of range, sensor module temperature, and electronics
temperature. The display updates based on the wireless update
rate.
1.
The overpressure limit of a DP Sensor with the P9 option is 4500 psig (310,3
bar). The overpressure limit of a DP Sensor with the P0 option is 6092 psig
(420 bar).
In-line sensor module
Range
Update rate
User selectable 1 second to 60 minutes.
120
GP
AP
3051S_TG
3051SAM_ _T
3051S_TA
3051SAM_ _E
1
750 psi (51,71 bar)
2
1500 psi (103,42 bar)
3
1600 psi (110,32 bar)
4
6000 psi (413,69 bar)
5
15000 psi (1034,21 bar)
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Coplanar multivariable sensor module
(3051SMV_ _1 or 2, 3051SF_1, 2, 5, or 6)
Coplanar multivariable sensor module
(3051SMV_ _1 or 2, 3051SF_1, 2, 5, or 6)
DP
Range
Static pressure range (GP/AP)
3
4
1
1600 psi (110,32 bar)
2000 psi (137,90 bar)
2
1600 psi (110,32 bar)
3626 psi (250,00 bar)
3
1600 psi (110,32 bar)
3626 psi (250,00 bar)
4
N/A
5
N/A
DP
Range
Static pressure range (GP/AP)
3
4
1
800 psi (55,15 bar)
2000 psi (137,90 bar)
3626 psi (250,00 bar)
2
800 psi (55,15 bar)
3626 psi (250,00 bar)
3626 psi (250,00 bar)
3
800 psi (55,15 bar)
3626 psi (250,00 bar)
4
N/A
3626 psi (250,00 bar)
5
N/A
3626 psi (250,00 bar)
Liquid level transmitter (3051SAL)
Overpressure limit is dependent on the flange rating or sensor
rating (whichever is lower). Use Instrument Toolkit to ensure the
seal system meets all pressure and temperature limits.
Static pressure limits
Coplanar sensor module (single variable)
Operates within specifications between static line pressures of:
DP Sensor(1)
Range
3051S_CD
3051SMV_ _3 or 4
3051SF_3, 4, 7, or D
0
0.5 psia to 750 psig (0,03 to 51,71 bar)
1
0.5 psia to 2000 psig (0,03 to 137,90 bar)
2
0.5 psia to 3626 psig (0,03 to 250,00 bar)
3
0.5 psia to 3626 psig (0,03 to 250,00 bar)
4
0.5 psia to 3626 psig (0,03 to 250,00 bar)
5
0.5 psia to 3626 psig (0,03 to 250,00 bar)
1.
Operates within specifications between static line pressures of
0.5 psia (0,03 bar) and the values in the table below:
Maximum working pressure limits
Maximum working pressure is the maximum pressure allowed
for normal transmitter operation. For a differential pressure
transmitter, the maximum working pressure is the static line
pressure under which the transmitter can safely operate. If one
side of the transmitter is exposed to the full static line pressure
due to mis-valving, the transmitter will experience an output
shift and must be re-zeroed. For a gage or absolute pressure
transmitter, the maximum working pressure is the same as the
Upper Range Limit (URL). The maximum working pressure of
transmitters with assemble-to options is limited by the lowest
maximum pressure rating of the individual components.
The static pressure limit of a DP Sensor with the P9 option is 4500 psig
(310,26 bar). The static pressure limit of a DP Sensor with the P0 option is
6092 psig (420,00 bar).
Emerson.com/Rosemount
121
Rosemount 3051S Series
October 2017
Table 20. Rosemount 3051S Maximum Working Pressure
Range
3051S_CD
3051SAL_ _D
3051SAM_ _D
3051S_CG
3051SAL_ _G
3051SAM_ G
3051S_CA
3051SAL_ _A
3051SAM_ _A
3051S_TA
3051SAL_ _E
3051SAM_ _E
3051S_TG
3051SAL_ _T
3051SAM_ _T
0
750 psi
51.7 bar
5.17 mpa
N/A
5 psia
0.35 bar-a
.035 mpa
N/A
N/A
1
2000 psi
138 bar
13.8 mpa
0.9 psi
0.062 bar
0.0062 mpa
30 psia
2.07 bar-a
0.207 mpa
30 psia
2.07 bar-a
0.207 mpa
30 psia
2.07 bar-a
0.207 mpa
2
3626 psi
250 bar
25 mpa
9 psi
0.62 bar
0.062 mpa
150 psia
10.3 bar-a
1.03 mpa
150 psia
10.3 bar-a
1.03 mpa
150 psi
10.3 bar-a
1.03 mpa
3
3626 psi
250 bar
25 mpa
36 psi
2.48 bar
0.248 mpa
800 psia
55.2 bar-a
5.52 mpa
800 psia
55.2 bar-a
5.52 mpa
800 psia
55.2 bar-a
5.52 mpa
4
3626 psi
250 bar
25 mpa
300 psi
20.7 bar
2.07 mpa
4000 psia
276 bar-a
27.6 mpa
4000 psia
276 bar-a
27.6 mpa
4000 psia
276 bar-a
27.6 mpa
5
3626 psi
250 bar
25 mpa
2000 psi
138 bar
13.8 mpa
N/A
10000psia
690 bar-a
69.0 mpa
10000psia
690 bar-a
69.0 mpa
Note
The maximum working pressure limit of a DP Sensor with the P9
option is 4500 psig (310,26 bar). The maximum working
pressure limit of a DP Sensor with the P0 option is 6092 psig
(420,00 bar).
Burst pressure limits
Coplanar sensor module
(3051S_C, 3051SMV, 3051SF, 3051SAM_ _G or A)
10000 psig (689,47 bar)
Table 21. Rosemount 3051SMV Maximum Working
Pressure (3051SMV1M1[X]G[Y]R2E12A1A)
In-line sensor module
(3051S_T, 3051SAM_ _T or E)
X = DP Range Y = 3 (DP/AP Range) Y = 4 (GP/AP Range)

Ranges 1-4: 11000 psi (758,42 bar)

Range 5: 26000 psi (1792,64 bar)
1
800 psi
55.2 bar
5.52 mpa
2000 psi
138 bar
13.8 mpa
2
800 psi
55.2 bar
5.52 mpa
3626 psi
250 bar
25 mpa
3
800 psi
55.2 bar
5.52 mpa
3626 psi
250 bar
25 mpa
4 and 5
3626 psi
250 bar
25 mpa
3626 psi
250 bar
25 mpa
Temperature limits
Ambient
–40 to 185 °F (–40 to 85 °C)
With LCD display(1): –40 to 176 °F (–40 to 80 °C)
With option code P0: –20 to 185 °F (–29 to 85 °C)
Storage
–50 to 185 °F (–46 to 85 °C)
With LCD display: –40 to 185 °F (–40 to 85 °C)
With Wireless Output: –40 to 185 °F (–40 to 85 °C)
1.
122
LCD display may not be readable and LCD display updates will be slower at
temperatures below -4 °F (-20 °C).
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Process temperature limits
At atmospheric pressures and above:(8)
Thermal Range Expander temperature operating
range
100
Coplanar sensor module
3051S_C, 3051SMV, 3051SF, 3051SAM_ _G or A
with 305 integral manifold
–40 to 300 °F (–40 to 149 °C)(3)(4)
Inert fill sensor(1)(5)
–40 to 185 °F (–40 to 85 °C)(6) (7)
–40 to 250 °F (–40 to 121 °C)(3)
Inert fill sensor(1)
–22 to 250 °F (–30 to 121 °C)(3)
3051SAL Level Transmitter
SYLTHERM XLT
–157 to 293 °F (–105 to 145 °C)
Silicone 704(8)
32 to 599 °F (0 to 315 °C)
Silicone 705(8)
68 to 698 °F (20 to 370 °C)
UltraTherm 805
Up to 770 °F (410 °C)
Silicone 200
–49 to 401 °F (–45 to 205 °C)
Inert (Halocarbon)
–49 to 320 °F (–45 to 160 °C)
Glycerin and water
5 to 203 °F (–15 to 95 °C)
Neobee M-20(9)
5 to 437 °F (–15 to 225 °C)
Propylene Glycol and Water
5 to 203 °F (–15 to 95 °C)
Process temperatures above 185 °F (85 °C) require derating the ambient limits
by a 1.5:1 ratio. For example, for process temperature of 195 °F
(91 °C), new ambient temperature limit is equal to 170 °F (77 °C). This can be
determined as follows:
(195 °F - 185 °F) ⫻ 1.5 = 15 °F,
185 °F - 15 °F = 170 °F
-20
-40
-60
In-line sensor module
3051S_T, 3051SAM_ _T or E
Silicone fill sensor(1)
0
-80
-30
10
50
90
130
170
210
250
290
330
370
410
Process Temperature (°C)
Humidity limits
0–100% relative humidity
Turn-on time(1)(2)
When power is applied to the transmitter during startup,
performance will be within specifications per the time period
described below:
Transmitter
Turn-on time (typical)
3051S, 3051SF_D, 3051SAL_ _C
2 seconds
Diagnostics
5 seconds
3051SMV, 3051SF_1-7
5 seconds
3051S ERS System
6 seconds
1.
Does not apply to wireless option code X.
2.
For option code F, device will communicate on a segment in less than 10
seconds
Volumetric displacement
2.
212 °F (100 °C) is the upper process temperature limit for DP Range 0.
3.
220 °F (104 °C) limit in vacuum service; 130 °F (54 °C) for pressures below 0.5
psia.
Less than 0.005 in3 (0,08 cm3)
4.
–20 °F (–29 °C) is the lower process temperature limit with option code P0.
Damping(1)
5.
32 °F (0 °C) is the lower process temperature limit for DP Range 0.
6.
For 3051S_C, 160 ° F (71 °C) limit in vacuum service.
For 3051SMV_ _ 1, 2, 140 ° F (60 °C) limit in vacuum service.
7.
Not available for 3051S_CA.
8.
Upper temperature limit is 401 °F (205 °C) for no direct mount extension, 464
°F (240 °C) for a 2-in. direct mount extension, and 500 °F (260 °C) for 4-in.
direct mount extension.
9.
Upper temperature limit is 401 °F (205 °C) for a no direct mount extension.
Analog output response time to a step change is user-selectable
from 0 to 60 seconds for one time constant. For Rosemount
3051SMV, 3051SF_1-7, each variable can be individually
adjusted. Software damping is in addition to sensor module
response time.
1.
Emerson.com/Rosemount
410 ° C
–40 to 300 °F (–40 to 149 °C)(3)
UltraTherm
805
20
370 ° C
with level flange
Silicone 705
40
315 ° C
–40 to 300 °F (–40 to 149 °C)(3)(4)
Ambient Temperature (°C)
–40 to 250 °F (–40 to 121 °C)(3)
with traditional flange
1.
Silicone 704
60
Silicone sill sensor(1)(2)
with coplanar flange
80
Does not apply to wireless option code X.
123
Rosemount 3051S Series
October 2017
Failure mode alarm
Process connections
4–20 mA HART (output option code A)
If self-diagnostics detect a gross transmitter failure, the analog
signal will be driven offscale to alert the user. Rosemount
standard (default), NAMUR, and custom alarm levels are
available (see Alarm configuration below).
High or low alarm signal is software-selectable or
hardware-selectable via the optional switch (option D1).
Alarm configuration
High alarm
Low alarm
Default
≥ 21.75 mA
≤ 3.75 mA
NAMUR compliant(1)
≥ 22.5 mA
≤ 3.6 mA
20.2 - 23.0 mA
3.4 - 3.8 mA
Custom levels(2)(3)
1.
Analog output levels are compliant with NAMUR recommendation NE 43,
see option codes C4 or C5.
2.
Low alarm must be 0.1 mA less than low saturation and high alarm must be
0.1 mA greater than high saturation.
3.
For Rosemount 3051SMV and option code DA2, low alarm custom values
are 3.6 - 3.8 mA.
Physical specifications
Material selection
Emerson provides a variety of Rosemount products with various
product options and configurations including materials of
construction that can be expected to perform well in a wide
range of applications. The Rosemount product information
presented is intended as a guide for the purchaser to make an
appropriate selection for the application. It is the purchaser’s
sole responsibility to make a careful analysis of all process
parameters (such as all chemical components, temperature,
pressure, flow rate, abrasives, contaminants, etc.), when
specifying product materials, options, and components for the
particular application. Emerson is not in a position to evaluate or
guarantee the compatibility of the process fluid or other process
parameters with the product options, configuration, or
materials of construction selected.
Coplanar sensor module
(3051S_C, 3051SMV, 3051SF, 3051SAM_ _G or A)
Standard
1 4
/ –18 NPT on 21/8-in. centers
Flange
Adapters
1 2
/ –14 NPT and RC 1/2 on 2-in. (50.8 mm), 21/8-in.
(54.0 mm), or 21/4-in. (57.2 mm) centers
In-line sensor module (3051S_T, 3051SAM_ _T or E)
Standard
1 2
/ –14 NPT Female
F11 Code
Non-threaded instrument flange (available in SST
for sensor ranges 1–4 only)
G11 Code
G 1/2 A DIN 16288 male (available in SST for sensor
ranges 1–4 only)
H11 Code
Autoclave type F-250C (Pressure relieved 9/16–18
gland thread; 1/4 OD high pressure tube 60° cone;
available in SST for sensor range 5 only)
Level transmitter (3051SAL)
FF Seal
PF Seal
EF Seal
2-in. (DN 50), 3-in. (DN 80), or 4-in. (DN 100); ANSI
Class 150, 300, 600, 900, 1500, and 2500 flange;
JIS 10K, 20K, or 40K flange; PN 10/16 or PN 40
flange
RF Seal
1-in. (DN 25) or 11/2-in. (DN 40); ANSI Class 150,
300, or 600 flange; JIS 10K, 20K, or 40K flange; PN
40 flange
RT Seal
1 4
FC Seal
2-in. or 3-in.; ANSI Class 150, 300, 600, 900, 1500,
2500 flange; PN 63 or PN 100 flange
/ –18, 1/2–14, 3/4–14, or 1–11.5 NPT Female
RC Seal
/ -in., 3/4-in., 1-in., or 11/2-in.; ANSI Class 150, 300,
600, 900, 1500, 2500 flange; PN 63 or PN 100
flange
SC Seal
11/2-in, 2-in, or 3-in. Hygienic Tri-Clover Style
Tri Clamp
SS Seal
4-in. Hygienic Tank Spud
1 2
Electrical connections
/ –14 NPT, G1/2, and M20 ⫻ 11/2 conduit. HART interface
connections fixed to terminal block for Output code A and X.
1 2
124
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Process-wetted parts
Non-wetted parts
Process isolating diaphragms
Electronics housing
Coplanar sensor module (3051S_C, 3051SMV)
Low-copper aluminum alloy or CF-8M (Cast 316 SST)
316L SST (UNS S31603), Alloy C-276 (UNS N10276), Alloy 400
(UNS N04400), Tantalum (UNS R05440), Gold-Plated Alloy
400, Gold-plated 316L SST
Enclosures meet NEMA® Type 4X, IP66, and IP68 [66 ft (20 m)
for 168 hours] when properly installed.
B11 Code
Note
IP 68 not available with Wireless output.
Low side process connection is SST
In-line sensor module (3051S_T)
316L SST (UNS S31603), Alloy C-276 (UNS N10276)
Coplanar sensor module housing
Level transmitter (3051SAL)
SST: CF-3M (Cast 316L SST)
FF Seal
Bolts
EF Seal
Plated carbon steel per ASTM A449, Type 1
Austenitic 316 SST per ASTM F593
ASTM A453, Class D, Grade 660 SST
ASTM A193, Grade B7M alloy steel
ASTM A193, Class 2, Grade B8M SST
Alloy K-500
RF Seal
RT Seal
316L SST, Alloy C-276, Tantalum
PF Seal
FC Seal
RC Seal
SC Seal
SS Seal
Sensor module fill fluid
316L SST, Alloy C-276
Drain/vent valves
316 SST, Alloy C-276, or Alloy 400/K-500(1) material
(Drain vent seat: Alloy 400, Drain vent stem: Alloy K-500)
Process flanges and flange adapters
Plated carbon steel
SST: CF-8M (Cast 316 SST) per ASTM A743
Cast C-276: CW-12MW per ASTM A494
Cast Alloy 400: M-30C per ASTM A494
Silicone is standard.
Inert is available as option code (L1).(2)
Inert for in-line series uses Fluorinert™ FC-43.
Inert for coplanar series uses Halocarbon.
Seal fill fluid (liquid level only)
Rosemount 3051SAL: Silicone 200, Silicone 704, Silicone 705,
UltraTherm 805, inert, SYLTHERM XLT, Neobee M-20, glycerin
and water, propylene glycol and water.
Paint for aluminum housing
Polyurethane
Wetted O-rings
Cover O-rings
Glass-filled PTFE
(Graphite-filled PTFE with isolating diaphragm code 6)
Buna-N
Rosemount 3051SAL mounting flange
Wireless antenna
Zinc-cobalt plated CS or 316 SST
External antenna (WK/WM): PBT/PC integrated omni-directional
antenna
Rosemount 3051SAL seal extension
Remote antenna (WN): Fiberglass omni-directional antenna
CF-3M (Cast 316L SST, material per ASTM A743) or
CW-12MW (Cast C-276, material per ASTM A494)
1.
Alloy 400/K-500 is not available with Rosemount 3051SAL.
2.
Inert is not available with Rosemount 3051S_CA.
Emerson.com/Rosemount
125
Rosemount 3051S Series
October 2017
Power module
Field replaceable, keyed connection eliminates the risk of
incorrect installation, Intrinsically Safe Lithium-thionyl chloride
Power module with PBT enclosure Shipping weights
Sensor module weights
Coplanar sensor module(1)
3.1 lb (1,4 kg)
In-line sensor module
1.4 lb (0,6 kg)
1.
Flange and bolts not included.
Transmitter weights(1)
Transmitter with coplanar sensor module
(3051S_C, 3051SMV, 3051SAM_ _G or A)
Junction Box housing, SST Flange
6.3 lb (2,8 kg)
Plantweb housing, SST Flange
6.7 lb (3,1 kg)
Wireless Plantweb housing, SST Flange
7.3 lb (3,3 kg)
Transmitter with in-line sensor module
(3051S_T, 3051SAM_ _T or E)
Junction Box housing
3.2 lb (1,4 kg)
Plantweb housing
3.7 lb (1,7 kg)
Wireless Plantweb housing
4.2 lb (1,9 kg)
1.
126
Fully functional transmitter with sensor module, housing, terminal block,
and covers. Does not include LCD display.
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Transmitter option weights
Add lb (kg)
Option code
Option
1J, 1K, 1L
SST Plantweb housing
3.5 (1,6)
2J
SST junction box housing
3.4 (1,5)
7J
SST quick connect
0.4 (0,2)
2A, 2B, 2C
Aluminum junction box housing
1.1 (0,5)
1A, 1B, 1C
Aluminum Plantweb housing
1.1 (0,5)
M5(1)
LCD display for aluminum Plantweb housing
LCD display for SST Plantweb housing
0.8 (0,4)
1.6 (0,7)
B4
SST mounting bracket for coplanar flange
1.2 (0,5)
B1, B2, B3
Mounting bracket for traditional flange
1.7 (0,8)
B7, B8, B9
Mounting bracket for traditional flange with SST Bolts
1.7 (0,8)
BA, BC
SST bracket for traditional flange
1.6 (0,7)
B4
SST mounting Bracket for in-line
1.3 (0,6)
F12, F22(2)
SST traditional flange with SST Drain Vents
3.2 (1,5)
F13, F23(2)
Cast C-276 traditional flange with Alloy C-276 Drain Vents
3.6 (1,6)
E12, E22(2)
SST coplanar Flange with SST Drain Vents
1.9 (0,9)
F14, F24(2)
Cast Alloy 400 traditional flange with Alloy 400/K-500 Drain Vents
3.6 (1,6)
F15, F25(2)
SST traditional flange with Alloy C-276 Drain Vents(2)
3.2 (1,5)
G21
Level flange—3 in., 150
12.6 (5,7)
G22
Level flange—3 in., 300
15.9 (7,2)
G11
Level flange—2 in., 150
6.8 (3,1)
G12
Level flange—2 in., 300
8.2 (3,7)
G31
DIN level flange, SST, DN 50, PN 40
7.8 (3,5)
G41
DIN level flange, SST, DN 80, PN 40
13.0 (5,9)
1.
Includes LCD display and display cover.
2.
Includes mounting bolts.
Emerson.com/Rosemount
127
Rosemount 3051S Series
October 2017
Transmitter component weights
Item
Weight in lb. (kg)
Aluminum Standard Cover
0.4 (0,2)
SST Standard Cover
1.3 (0,6)
Aluminum Display Cover
0.7 (0,3)
SST Display Cover
1.5 (0,7)
Wireless Extended Cover
0.7 (0,3)
LCD Display(1)
0.1 (0,04)
Junction Box Terminal Block
0.2 (0,1)
Plantweb Terminal Block
0.2 (0,1)
Power Module
0.5 (0,2)
1.
Display only.
Rosemount 3051SAL weights without supermodule platform, housing, or transmitter options
Flange
Flush
lb. (kg)
2-in. Ext.
lb (kg)
4-in. Ext.
lb (kg)
6-in. Ext.
lb (kg)
2-in., Class 150
9.5 (4,3)
N/A
N/A
N/A
3-in., Class 150
15.7 (7,1)
16.4 (7,4)
17.6 (8,0)
18.9 (8,6)
4-in., Class 150
21.2 (9,6)
20.9 (9,5)
22.1 (10,0)
23.4 (10,6)
2-in., Class 300
11.3 (5,1)
N/A
N/A
N/A
3-in., Class 300
19.6 (8,9)
20.3 (9,2)
21.5 (9,8)
22.8 (10,3)
4-in., Class 300
30.4 (13,8)
30.3 (13,7)
31.5 (14,3)
32.8 (14,9)
2-in., Class 600
12.8 (5,8)
N/A
N/A
N/A
3-in., Class 600
22.1 (10,0)
22.8 (10,3)
24.0 (10,9)
25.3 (11,5)
DN 50/PN 40
11.3 (5,1)
N/A
N/A
N/A
DN 80/PN 40
16.0 (7,3)
16.7 (7,6)
17.9 (8,1)
19.2 (8,7)
DN 100/PN 10/16
11.2 (5,1)
11.9 (5,4)
13.1 (5,9)
14.4 (6,5)
DN 100/PN 40
12.6 (5,7)
13.3 (6,0)
14.5 (6,6)
15.8 (7,1)
128
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Product Certifications
Rosemount 3051S/3051SFx/3051S-ERS
Rev 1.12
European Directive Information
Special Condition for Safe Use:
A copy of the EU Declaration of Conformity can be found at the
end of the Quick Start Guide. The most recent revision of the EU
Declaration of Conformity can be found at
Emerson.com/Rosemount.
1. The Rosemount 3051S/3051S-ERS Pressure Transmitter
contains aluminum and is considered to constitute a
potential risk of ignition by impact or friction. Care must
be taken into account during installation and use to
prevent impact and friction.
Ordinary Location Certification
As standard, the transmitter has been examined and tested to
determine that the design meets the basic electrical,
mechanical, and fire protection requirements by a nationally
recognized test laboratory (NRTL) as accredited by the Federal
Occupational Safety and Health Administration (OSHA).
Installing Equipment in North America
Note
Transmitters marked with NI CL 1, DIV 2 can be installed
in Division 2 locations using general Division 2 wiring
methods or Nonincendive Field Wiring (NIFW). See
Drawing 03151-1006.
IE
FM FISCO
Certificate: FM16US0089X
Standards: FM Class 3600 - 2011, FM Class 3610 - 2010,
FM Class 3611 - 2004, FM Class 3810 - 2005,
NEMA 250 - 2003
Markings: IS CL I, DIV 1, GP A, B, C, D; T4(–50 °C ≤ Ta ≤
+60 °C); when connected per Rosemount
drawing 03151-1006; Type 4X
The US National Electrical Code (NEC®) and the Canadian
Electrical Code (CEC) permit the use of Division marked
equipment in Zones and Zone marked equipment in Divisions.
The markings must be suitable for the area classification, gas,
and temperature class. This information is clearly defined in the
respective codes.
USA
E5
I5
FM Explosionproof (XP) and Dust-Ignitionproof (DIP)
Certificate: FM16US0090
Standards: FM Class 3600 - 2011, FM Class 3615 - 2006,
FM Class 3616 - 2011, FM Class 3810 - 2005,
ANSI/NEMA 250 - 2003
Markings: XP CL I, DIV 1, GP B, C, D; DIP CL II, DIV 1, GP E,
F, G; CL III; T5(–50 °C ≤ Ta ≤ +85 °C); Factory
Sealed; Type 4X
FM Intrinsic Safety (IS) and Nonincendive (NI)
Certificate: FM16US0089X
Standards: FM Class 3600 - 2011, FM Class 3610 - 2010,
FM Class 3611 - 2004, FM Class 3810 - 2005,
NEMA® 250 - 2003
Markings: IS CL I, DIV 1, GP A, B, C, D; CL II, DIV 1, GP E, F,
G; Class III; Class 1, Zone 0 AEx ia IIC T4; NI CL 1,
DIV 2, GP A, B, C, D; T4(–50 °C ≤ Ta ≤ +70 °C)
[HART]; T4(–50 °C ≤ Ta ≤ +60 °C) [Fieldbus];
when connected per Rosemount drawing
03151-1006; Type 4X
Emerson.com/Rosemount
Special Condition for Safe Use (X):
1. The Rosemount™ 3051S/3051S-ERS Pressure Transmitter
contains aluminum and is considered to constitute a
potential risk of ignition by impact or friction. Care must
be taken into account during installation and use to
prevent impact and friction.
Canada
E6
CSA Explosionproof, Dust-Ignitionproof, and Division 2
Certificate: 1143113
Standards: CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No.
25-1966, CSA Std C22.2 No. 30-M1986,
CAN/CSA C22.2 No. 94-M91, CSA Std C22.2
No. 142-M1987, CSA Std C22.2 No.
213-M1987, ANSI/ISA 12.27.01-2003, CSA Std
C22.2 No. 60529:05
Markings: Explosionproof Class I, Division 1, Groups B, C,
D; Dust-Ignitionproof Class II, Division 1,
Groups E, F, G; Class III; suitable for Class I, Zone
1, Group IIB+H2, T5; suitable for Class I,
Division 2, Groups A, B, C, D; suitable for Class I,
Zone 2, Group IIC, T5; when connected per
Rosemount drawing 03151-1013; Type 4X
129
Rosemount 3051S Series
I6
October 2017
Canada Intrinsically Safe
Certificate: 143113
Standards: CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No.
25-1966, CSA Std C22.2 No. 30-M1986,
CAN/CSA C22.2 No. 94-M91, CSA Std C22.2
No. 142-M1987, CSA Std C22.2 No.
213-M1987, ANSI/ISA 12.27.01-2003, CSA Std
C22.2 No. 60529:05
Markings: Exploected per Rosemount drawing
03151-1016 [3051S] 03151-1313 [ERS]; Type
4X
IF
CSA FISCO
Certificate: 1143113
Standards: CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No.
30-M1986, CAN/CSA C22.2 No. 94-M91, CSA
Std C22.2 No. 142-M1987, CSA Std C22.2 No.
157-92, ANSI/ISA 12.27.01-2003, CSA Std
C22.2 No. 60529:05
Markings: FISCO Intrinsically Safe Class I, Division 1;
Groups A, B, C, D; suitable for Class 1, Zone 0,
IIC, T3C; when connected per Rosemount
drawing 03151-1016 [3051S] 03151-1313
[ERS]; Type 4X
Europe
E1
ATEX Flameproof
Certificate: KEMA 00ATEX2143X
Standards: EN 60079-0:2012+A11:2013, EN
60079-1:2014, EN 60079-26:2015
Markings:
II 1/2 G Ex db IIC T6…T4 Ga/Gb, T6(–60 °C ≤
Ta ≤ +70 °C), T5/T4(–60 °C ≤ Ta ≤ +80 °C)
Table 22. Process Temperature
Temperature class
Process temperature
T6
–60 °C to +70 °C
T5
–60 °C to +80 °C
T4
–60 °C to +120 °C
Special Conditions for Safe Use (X):
1. This device contains a thin wall diaphragm less than 1 mm
thickness that forms a boundary between EPL Ga (process
connection) and EPL Gb (all other parts of the equipment).
The model code and datasheet are to be consulted for
details of the diaphragm material. Installation,
maintenance and use shall take into account the
environmental conditions to which the diaphragm will be
subjected. The manufacturer's instructions for installation
and maintenance shall be followed in detail to assure
safety during its expected lifetime.
2. Flameproof joints are not intended for repair.
3. Non-standard paint options may cause risk from
electrostatic discharge. Avoid installations that could
cause electrostatic build-up on painted surfaces, and only
clean the painted surfaces with a damp cloth. If paint is
ordered through a special option code, contact the
manufacturer for more information.
4. Appropriate cable, glands and plugs need to be suitable for
a temperature of 5 °C greater than maximum specified
temperature for location where installed.
I1
ATEX Intrinsic Safety
Certificate: Baseefa08ATEX0064X
Standards: EN 60079-0: 2012, EN 60079-11: 2012
Markings:
II 1 G Ex ia IIC T4 Ga, T4(–60 °C ≤ Ta ≤ +70 °C)
Table 23. Input Parameters
Ui
Ii
Pi
Ci
Li
SuperModule
30 V 300 mA
1.0 W
30 nF
0
3051S...A;
3051SF…A;
3051SAL…C
30 V 300 mA
1.0 W
12 nF
0
3051S…F;
3051SF…F
30 V 300 mA
1.0 W
0
0
3051S
…A…M7, M8,
or M9;
3051SF
…A…M7, M8,
or M9;
3051SAL…C…
M7, M8, or M9
30 V 300 mA
1.0 W
12 nF
60 μH
3051SAL or
3051SAM
30 V 300 mA
1.0 W
12 nF
33 μH
3051SAL…M7,
M8, or M9
30 V 300 mA
3051SAM…M7,
M8, or M9
1.0 W
12 nF
93 μH
N/A
N/A
RTD Option for
3051SF
5V
500 mA 0.63 W
Special Conditions for Safe Use (X):
1. The Rosemount 3051S Transmitters fitted with transient
protection are not capable of withstanding the 500 V test
as defined in Clause 6.3.13 of EN 60079-11:2012. This
must be taken into account during installation.
2. The terminal pins of the Rosemount 3051S SuperModule
must be provided with a degree of protection of at least
IP20 in accordance with IEC/EN 60529.
130
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
3. The Rosemount 3051S enclosure may be made of
aluminum alloy and given a protective polyurethane paint
finish; however, care should be taken to protect it from
impact or abrasion if located in a zone 0 area.
IA
ATEX FISCO
Certificate: BAS01ATEX1303X
Standards: EN 60079-0: 2012+A11:2013, EN 60079-11:
2012
Markings:
II 1 G Ex ia IIC T4 Ga, T4(–60 °C ≤ Ta ≤ +70 °C)
Table 24. Input Parameters
Parameter
Special Condition for Safe Use (X):
1. The equipment is not capable of withstanding the 500 V
insulation test required by clause 6.5 of EN
60079-15:2010. This must be taken into account when
installing the equipment.
Note
RTD Assembly is not included with the 3051SFx Type n
Approval.
International
FISCO
Voltage Ui
17.5 V
Current Ii
380 mA
Power Pi
5.32 W
Capacitance Ci
0
Inductance Li
0
E7
Table 25. Process Temperature
Special Conditions for Safe Use (X):
1. The Rosemount 3051S Transmitters fitted with transient
protection are not capable of withstanding the 500 V test
as defined in Clause 6.3.13 of EN 60079-11:2012. This
must be taken into account during installation.
2. The terminal pins of the Rosemount 3051S SuperModule
must be provided with a degree of protection of at least
IP20 in accordance with IEC/EN 60529.
1.
4. The SuperModule(s) must be securely screwed in place to
maintain the ingress protection of the enclosure(s).
N1 ATEX Type n
Certificate: BAS01ATEX3304X
Standards: EN 60079-0: 2012+A11:2013, EN 60079-15:
2010
Markings:
II 3 G Ex nA IIC T4 Gc, (–40 °C ≤ Ta ≤ 85 °C),
Vmax = 45 V
Emerson.com/Rosemount
T6
–60 °C to +70 °C
T5
–60 °C to +80 °C
T4
–60 °C to +120 °C
This device contains a thin wall diaphragm less than 1 mm
thickness that forms a boundary between EPL Ga (process
connection) and EPL Gb (all other parts of the equipment).
The model code and datasheet are to be consulted for
details of the diaphragm material. Installation,
maintenance and use shall take into account the
environmental conditions to which the diaphragm will be
subjected. The manufacturer's instructions for installation
and maintenance shall be followed in detail to assure safety
during its expected lifetime.
Flameproof joints are not intended for repair.
3.
Non-standard paint options may cause risk from
electrostatic discharge. Avoid installations that could cause
electrostatic build-up on painted surfaces, and only clean
the painted surfaces with a damp cloth. If paint is ordered
through a special option code, contact the manufacturer
for more information.
4.
Appropriate cable, glands and plugs need to be suitable for
a temperature of 5 °C greater than maximum specified
temperature for location where installed.
1. Cable entries must be used which maintain the ingress
protection of the enclosure to at least IP66.
3. Cable entries and blanking plugs must be suitable for the
ambient temperature range of the apparatus and capable
of withstanding a 7J impact test.
Process temperature
2.
Special Conditions for Safe Use (X):
2. Unused cable entries must be filled with suitable blanking
plugs which maintain the ingress protection of the
enclosure to at least IP66.
Temperature class
Special Conditions for Safe Use (X):
3. The Rosemount 3051S enclosure may be made of
aluminum alloy and given a protective polyurethane paint
finish; however, care should be taken to protect it from
impact or abrasion if located in a zone 0 area.
ND ATEX Dust
Certificate: BAS01ATEX1374X
Standards: EN 60079-0: 2012+A11:2013, EN 60079-31:
2009
Markings:
II 1 D Ex ta IIIC T105 °C T50095 °C Da,
(–20 °C ≤ Ta ≤ +85 °C), Vmax = 42.4 V
IECEx Flameproof and Dust
Certificate: IECEx KEM 08.0010X (Flameproof)
Standards: IEC 60079-0:2011, IEC 60079-1:2014, IEC
60079-26:2014
Markings: Ex db IIC T6…T4 Ga/Gb, T6(–60 °C ≤ Ta ≤
+70 °C), T5/T4(–60 °C ≤ Ta ≤ +80 °C)
Certificate: IECEx BAS 09.0014X (Dust)
Standards: IEC 60079-0:2011, IEC 60079-31:2008
Markings: Ex ta IIIC T105 °C T50095 °C Da,
(–20 °C ≤ Ta ≤ +85 °C), Vmax = 42.4 V
Special Conditions for Safe Use (X):
1. Cable entries must be used which maintain the ingress
protection of the enclosure to at least IP66.
131
Rosemount 3051S Series
October 2017
2. Unused cable entries must be filled with suitable blanking
plugs which maintain the ingress protection of the
enclosure to at least IP66.
3. Cable entries and blanking plugs must be suitable for the
ambient temperature range of the apparatus and capable
of withstanding a 7J impact test.
4. The 3051S- SuperModule must be securely screwed in
place to maintain the ingress protection of the enclosure.
I7
IECEx Intrinsic Safety
Certificate: IECEx BAS 04.0017X
Standards: IEC 60079-0: 2011, IEC 60079-11: 2011
Markings: Ex ia IIC T4 Ga, T4(–60 °C ≤ Ta ≤ +70 °C)
Table 26. Input Parameters
Ui
Ii
Pi
Ci
Li
SuperModule
30 V 300 mA
1.0 W
30 nF
0
3051S...A;
3051SF…A;
3051SAL…C
30 V 300 mA
1.0 W
12 nF
0
3051S…F;
3051SF…F
30 V 300 mA
1.0 W
0
0
3051S
…A…M7, M8,
or M9;
3051SF
30 V 300 mA
…A…M7, M8,
or M9;
3051SAL…C…
M7, M8, or M9
1.0 W
3051SAL or
3051SAM
30 V 300 mA
1.0 W
12 nF
33 μH
3051SAL…M7,
M8, or M9
30 V 300 mA
3051SAM…M7
, M8, or M9
1.0 W
12 nF
93 μH
RTD Option for
5V
3051SF
0.63 W
N/A
N/A
500 mA
12 nF
60 μH
I7
IECEx Intrinsic Safety - Group I - Mining (I7 with Special
A0259)
Certificate: IECEx TSA 14.0019X
Standards: IEC 60079-0: 2011, IEC 60079-11: 2011
Markings: Ex ia I Ma (–60 °C ≤ Ta ≤ +70 °C)
Table 27. Input Parameters
Ui
Ii
Pi
Ci
Li
SuperModule
30 V
300 mA
1.0 W
30 nF
0
3051S...A;
3051SF…A;
3051SAL…C
30 V
300 mA
1.0 W
12 nF
0
3051S…F;
3051SF…F
30 V
300 mA
1.0 W
0
0
3051S
…A…M7, M8,
or M9;
3051SF
…A…M7, M8,
or M9;
3051SAL…C…
M7, M8, or M9
30 V
300 mA
1.0 W
12 nF
60 μH
3051SAL or
3051SAM
30 V
300 mA
1.0 W
12 nF
33 μH
3051SAL…M7,
M8, or M9
30 V
3051SAM…M7,
M8, or M9
300 mA
1.0 W
12 nF
93 μH
RTD Option for
3051SF
500 mA
0.63 W
N/A
N/A
5V
Special Conditions for Safe Use (X):
1. If the apparatus is fitted with optional 90 V transient
suppressor, it is not capable of withstanding the 500 V
insulation test required by Clause 6.3.13 of IEC60079-11.
This must be taken into account when installing the
apparatus.
2. It is a condition of safe use that the above input parameters
shall be taken into account during installation.
Special Conditions for Safe Use (X):
1. The Rosemount 3051S Transmitters fitted with transient
protection are not capable of withstanding the 500 V test
as defined in Clause 6.3.13 of EN 60079-11:2012. This
must be taken into account during installation.
2. The terminal pins of the Rosemount 3051S SuperModule
must be provided with a degree of protection of at least
IP20 in accordance with IEC/EN 60529.
3. It is a condition of manufacture that only the apparatus
fitted with housing, covers and sensor module housing
made out of stainless steel are used in Group I applications.
IG
IECEx FISCO
Certificate: IECEx BAS 04.0017X
Standards: IEC 60079-0: 2011, IEC 60079-11: 2011
Markings: Ex ia IIC T4 Ga, T4(–60 °C ≤ Ta ≤ +70 °C)
3. The Rosemount 3051S enclosure may be made of
aluminum alloy and given a protective polyurethane paint
finish; however, care should be taken to protect it from
impact or abrasion if located in a zone 0 area.
132
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Special Condition for Safe Use (X):
Table 28. Input Parameters
Parameter
FISCO
Voltage Ui
17.5 V
Current Ii
380 mA
Power Pi
5.32 W
Capacitance Ci
0
Inductance Li
0
Special Conditions for Safe Use (X):
1. The Rosemount 3051S Transmitters fitted with transient
protection are not capable of withstanding the 500 V test
as defined in Clause 6.3.13 of EN 60079-11:2012. This
must be taken into account during installation.
2. The terminal pins of the Rosemount 3051S SuperModule
must be provided with a degree of protection of at least
IP20 in accordance with IEC/EN 60529.
3. The Rosemount 3051S enclosure may be made of
aluminum alloy and given a protective polyurethane paint
finish; however, care should be taken to protect it from
impact or abrasion if located in a zone 0 area.
IG
IECEx Intrinsic Safety - Group I - Mining (IG with Special
A0259)
Certificate: IECEx TSA 04.0019X
Standards: IEC 60079-0: 2011, IEC 60079-11: 2011
Markings: FISCO FIELD DEVICE Ex ia I Ma , (–60 °C ≤ Ta ≤
+70 °C)
Table 29. Input Parameters
1. The equipment is not capable of withstanding the 500 V
insulation test required by clause 6.5 of EN
60079-15:2010. This must be taken into account when
installing the equipment.
Brazil
E2
INMETRO Flameproof
Certificate: UL-BR15.0393X
Standards: ABNT NBR IEC 60079-0:2008 + Corrigendum
1:2011, ABNT NBR IEC 60079-1:2009 +
Corrigendum 1:2011, ABNT NBR IEC
60079-26:2008 + Corrigendum 1: 2008
Markings: Ex d IIC T* Ga/Gb, T6(–60 °C ≤ Ta ≤ +70 °C),
T5/T4(–60 °C ≤ Ta ≤ +85 °C), IP66
Special Conditions for Safe Use (X):
1. The device contains a thin wall diaphragm. Installation,
maintenance and use shall take into account the
environmental conditions to which the diaphragm will be
subjected. The manufacturer's instructions for installation
and maintenance shall be followed in detail to assure
safety during its expected lifetime.
2. For information on the dimensions of the flameproof
joints, the manufacturer shall be contacted.
I2/IB INMETRO Intrinsic Safety/FISCO
Certificate: UL-BR 15.0392X
Standards: ABNT NBR IEC 60079-0:2008 + Corrigendum
1:2011, ABNT NBR IEC 60079-11:2009
Markings: Ex ia IIC T4 Ga, T4(–60 °C ≤ Ta ≤ +70 °C), IP66
Special Condition for Safe Use (X):
Parameter
FISCO
Voltage Ui
17.5 V
Current Ii
380 mA
Power Pi
5.32 W
Capacitance Ci
0
Inductance Li
0
1. The 3051S enclosure may be made of aluminium alloy and
given a protective polyurethane paint finish; however, care
should be taken to protect it from impact or abrasion if
located in areas that requires EPL Ga.
Special Conditions for Safe Use (X):
1. If the apparatus is fitted with optional 90 V transient
suppressor, it is not capable of withstanding the 500 V
insulation test required by Clause 6.3.13 of IEC60079-11.
This must be taken into account when installing the
apparatus.
2. It is a condition of safe use that the above input parameters
shall be taken into account during installation.
3. It is a condition of manufacture that only the apparatus
fitted with housing, covers and sensor module housing
made out of stainless steel are used in Group I applications.
N7 IECEx Type n
Certificate: IECEx BAS 04.0018X
Standards: IEC 60079-0: 2011, IEC 60079-15: 2010
Markings: Ex nA IIC T5 Gc, (–40 °C ≤ Ta ≤ +85 °C)
Emerson.com/Rosemount
133
Rosemount 3051S Series
October 2017
Special Conditions for Safe Use (X):
Table 30. Input Parameters
SuperModule
Ui
Ii
Pi
Ci
Li
30 V
300 mA
1.0 W
30 nF
0
2. Flameproof joints are not intended for repair.
3051S...A;
3051SF…A;
3051SAL…C
30 V
300 mA
1.0 W
12 nF
0
3051S…F;
3051SF…F
30 V
300 mA
1.3 W
0
0
3051S
…A…M7, M8,
or M9;
3051SF
…A…M7, M8,
or M9;
3051SAL…C…
M7, M8, or M9
30 V
3051SAL or
3051SAM
30 V
300 mA
1.0 W
12 nF
60 μH
300 mA
1.0 W
12 nF
33 μH
4. The relation between temperature class and maximum
temperature of process medium is as follows:
T code
Ambient
temperature (°C)
Process
temperature (°C)
T6
–60 °C ≤ Ta ≤ +70 °C
–60 °C ≤ Ta ≤ +70 °C
T5
–60 °C ≤ Ta ≤ +80 °C
–60 °C ≤ Ta ≤ +80 °C
T4
–60 °C ≤ Ta ≤ +80 °C
–60 °C ≤ Ta ≤ +120 °C
6. During installation, use and maintenance of transmitter,
observe the warning "Don't open the cover when the
circuit is alive."
7. During installation, there should be no mixture harm to
flameproof housing.
30 V
300 mA
1.0 W
12 nF
93 μH
RTD Option for
3051SF
5V
500 mA
0.63 W
N/A
N/A
China
134
3. The ambient temperature range for the 3051S and
3051SFx in a dust environment is –20 °C ≤ Ta ≤ 85 °C.
5. The earth connection facility in the enclosure should be
connected reliably.
3051SAL…
M7, M8, or M9
3051SAM…
M7, M8, or M9
E3
1. Only the pressure transmitters, consisting of 3051SC
Series, 3051ST Series, 3051SL Series and 300S Series, are
certified.
China Flameproof and Dust Ignition-proof
Certificate: 3051S: GYJ16.1249X
3051SFx: GYJ16.1466X
3051S-ERS: GJY15.1406X
Standards: 3051S: GB3836.1-2010, GB3836.2-2010,
GB3836.20-2010, GB12476.1-2013,
GB12476.5-2013
3051SFx: GB3836.1-2010, GB3836.2-2010,
GB3836.20-2010, GB12476.1-2013, GB
12476.5-2013
3051S-ERS: GB3836.1-2010, GB3836.2-2010,
GB3836.20-2010
Markings: 3051S: Ex d IIC T6…T4; Ex tD A20 T105 °C
T50095 °C; IP66
3051SFx: Ex d IIC T5/T6 Ga/Gb; DIP A20 TA105
°C; IP66
3051S-ERS: Ex d IIC T4~T6 Ga/Gb
8. Cable entry, certified by NEPSI with type of protection Ex d
IIC in accordance with GB3836.1-2000 and
GB3836.2-2000, should be applied when installation in
hazardous location. 5 full threads should be in
engagement when the cable entry is assembled onto the
transmitter. When pressure transmitter is used in the
presence of combustible dust, the ingress of protection of
the cable entry should be IP66.
9. The diameter of cable should observe the instruction
manual of cable entry. The compressing nut should be
fastened. The aging of seal ring should be changed in time.
10. Maintenance should be done in non-hazardous location.
11. End users are not permitted to change any components
inside.
12. When installation, use and maintenance of transmitter,
observe following standards:
GB3836.13-2013 "Electrical apparatus for explosive gas
atmospheres Part 13: Repair and overhaul for apparatus
used in explosive gas atmospheres"
GB3836.15-2000 "Electrical apparatus for explosive gas
atmospheres Part 15: Electrical installations in hazardous
area (other than mines)"
GB3836.16-2006 "Electrical apparatus for explosive gas
atmospheres Part 16: Inspection and maintenance of
electrical installation (other than mines)"
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
GB50257-2014 "Code for construction and acceptance of
electric device for explosion atmospheres and fire hazard
electrical equipment installation engineering"
GB15577-20071995 "Safe regulation for explosive dust
atmospheres"
GB12476.2-2010 "Electrical apparatus for use in the
presence of combustible dust - Part 1-2: Electrical
apparatus protected by enclosures and surface
temperature limitation - Selection, installation and
maintenance"
I3
China Intrinsic Safety
Certificate: 3051S: GYJ16.1250X[Mfg USA, China,
Singapore]
3051SFx: GYJ16.1465X [Mfg USA, China,
Singapore]
3051S-ERS: GYJ16.1248X [Mfg USA, China,
Singapore]
Standards: 3051S: GB3836.1-2010, GB3836.4-2010,
GB3836.20-2010
3051SFx: GB3836.1/4-2010, GB3836.20-2010,
GB12476.1-2013, GB12476.5-2013
3051S-ERS: GB3836.1-2010, GB3836.4-2010,
GB3836.20-2010
Markings: 3051S, 3051SFx: Ex ia IIC T4 Ga
3051S-ERS: Ex ia IIC T4
Special Conditions for Safe Use (X):
1. Symbol "X" is used to denote specific conditions of use:
For output code A and F: This apparatus is not capable of
withstanding the 500V r.m.s. insulation test required by
Clause 6.4.12 of GB3836.4-2000.
2. The ambient temperature range is:
Output code
Ambient temperature
A
–50 °C ≤ Ta ≤ +70 °C
F
–50 °C ≤ Ta ≤ +60 °C
5. The cable between this product and associated apparatus
should be shielded cables (the cables must have insulated
shield). The shield has to be grounded reliably in
non-hazardous area.
6. The product complies to the requirements for FISCO field
devices specified in IEC60079-27:2008. For the connection
of an intrinsically safe circuit in accordance FISCO model,
FISCO parameters of this product are as above.
7. End users are not permitted to change any components
inside, but to settle the problem in conjunction with
manufacturer to avoid damage to the product.
8. When installation, use and maintenance of this product,
observe the following standards:
GB3836.13-2013 "Electrical apparatus for explosive gas
atmospheres Part 13: Repair and overhaul for apparatus
used in explosive gas atmospheres"
GB3836.15-2000 "Electrical apparatus for explosive gas
atmospheres Part 15: Electrical installations in hazardous
area (other than mines)"
GB3836.16-2006 "Electrical apparatus for explosive gas
atmospheres Part 16: Inspection and maintenance of
electrical installation (other than mines)"
GB3836.18-2010 "Intrinsically Safe System"
GB50257-20141996 "Code for construction and
acceptance of electric device for explosion atmospheres
and fire hazard electrical equipment installation
engineering"
N3 China Type n
Certificate: 3051S: GYJ15.1106X [Mfg China]
3051SF: GYJ15.1107X [Mfg China
Markings: Ex nA IIC T5 Gc
3. Intrinsically safe parameters:
Special Conditions for Safe Use (X):
Max internal
parameter
Max input
Output Housing Display
code
code
code
4. The product should be used with Ex-certified associated
apparatus to establish explosion protection system that
can be used in explosive gas atmospheres. Wiring and
terminals should comply with the instruction manual of
the product and associated apparatus.
Voltage: Current: Power:
C (nF) Li (uH)
Ui (V) Ii (mA) Pi (W) i
1. The ambient mperature range is: –40 °C ≤ Ta ≤ 85 °C.
2. Maximum input voltage: 45 V
A
=00
/
30
300
1
38
0
A
00
/
30
300
1
11.4
2.4
3. Cable glands, conduit or blanking plugs, certified by NEPSI
with Ex e or Ex n protection type and IP66 degree of
protection provided by enclosure, should be used on
external connections and redundant cable entries.
A
00
M7/M8
/M9
30
300
1
0
58.2
4. Maintenance should be done in non-hazardous location.
F
00
/
30
300
1.3
0
0
F
FISCO
00
/
17.5
500
5.5
0
0
Emerson.com/Rosemount
5. End users are not permitted to change any components
inside, but to settle the problem in conjunction with
manufacturer to avoid damage to the product.
135
Rosemount 3051S Series
6. When installation, use and maintenance of this product,
observe following standards:
GB3836.13-2013 "Electrical apparatus for explosive gas
atmospheres Part 13: Repair and overhaul for apparatus
used in explosive gas atmospheres"
GB3836.15-2000 "Electrical apparatus for explosive gas
atmospheres Part 15: Electrical installations in hazardous
area (other than mines)"
GB3836.16-2006 "Electrical apparatus for explosive gas
atmospheres Part 16: Inspection and maintenance of
electrical installation (other than mines)"
EAC - Belarus, Kazakhstan, Russia
EM Technical Regulation Customs Union (EAC) Flameproof
IM
October 2017
Combinations
K1 Combination of E1, I1, N1, and ND
K2 Combination of E2 and I2
K5 Combination of E5 and I5
K6 Combination of E6 and I6
K7 Combination of E7, I7, and N7
KA Combination of E1, I1, E6, and I6
KB Combination of E5, I5, E6, and I6
KC Combination of E1, I1, E5, and I5
KD Combination of E1, I1, E5, I5, E6, and I6
KG Combination of IA, IE, IF, and IG
KM Combination of EM and IM
Certificate: RU C-US.AA87.B.00378
KP Combination of EP and IP
Markings: Ga/Gb Ex d IIC T6…T4 X
Ex tb IIIC T105 °C T50095 °C Db X
Ex ta IIIC T105 °C T50095 °C Da X
Additional Certifications
SBS American Bureau of Shipping (ABS) Type Approval
Technical Regulation Customs Union (EAC) Intrinsic Safety
Certificate:
00-HS145383
Certificate: RU C-US.AA87.B.00094
Intended Use:
Measure gauge or absolute pressure of
liquid, gas or vapor applications on ABS
classed vessels, marine, and offshore
installations.
Markings: 0Ex ia IIC T4 Ga X
Japan
E4
Japan Flameproof
Certificate: TC15682, TC15683, TC15684, TC15685,
TC15686, TC15687, TC15688, TC15689,
TC15690, TC17099, TC17100, TC17101,
TC17102, TC18876
3051ERS: TC20215, TC20216, TC20217,
TC20218, TC20219, TC20220, TC20221
Markings: Ex d IIC T6
Republic of Korea
EP
SBV Bureau Veritas (BV) Type Approval
Certificate:
Requirements: Bureau Veritas Rules for the Classification
of Steel Ships
Application:
Class Notations: AUT-UMS, AUT-CCS,
AUT-PORT and AUT-IMS.
SDN Det Norske Veritas (DNV) Type Approval
Certificate:
A-14186
Intended Use:
Det Norske Veritas' Rules for Classification
of Ships, High Speed & Light Craft, and Det
Norske Veritas' Offshore Standards.
Republic of Korea Flameproof
Certificate: 12-KB4BO-0180X [Mfg USA], 11-KB4BO-0068X
[Mfg Singapore]
Application:
Markings: Ex d IIC T5 or T6
IP
31910 BV
Republic of Korea Intrinsic Safety
Certificate:12-KB4BO-0202X [HART - Mfg
USA],12-KB4BO-0204X [Fieldbus - Mfg USA],
12-KB4BO-0203X [HART - Mfg Singapore],
13-KB4BO-0296X [Fieldbus - Mfg Singapore]
Markings: Ex ia IIC T4
Location classes
Type
3051S
Temperature
D
Humidity
B
Vibration
A
EMC
A
Enclosure
D/IP66/IP68
SLL Lloyds Register (LR) Type Approval
Certificate:
11/60002
Application:
Environmental categories ENV1, ENV2,
ENV3, and ENV5. [HART Only]
D3 Custody Transfer - Measurement Canada Accuracy
Approval [3051S Only]
Certificate: AG-0501, AV-2380C
136
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Rosemount 3051S and 3051SMV Wireless
Rev 2.2
European Directive Information
Special Conditions for Safe Use (X):
1. The Rosemount 3051S and SMV Wireless Transmitters
shall only be used with the 701PBKKF Rosemount
SmartPower Battery Pack or alternatively the Perpetuum
Intelligent Power Module Vibration Harvester.
A copy of the EC Declaration of Conformity can be found at the
end of the Quick Start Guide. The most recent revision of the EC
Declaration of Conformity can be found at
Emerson.com/Rosemount.
2. The transmitter may contain more than 10% aluminum
and is considered a potential risk of ignition by impact or
friction.
Telecommunication Compliance
All wireless devices require certification to ensure that they
adhere to regulations regarding the use of the RF spectrum.
Nearly every country requires this type of product certification.
Emerson is working with governmental agencies around the
world to supply fully compliant products and remove the risk of
violating country directives or laws governing wireless device
usage.
3. The surface resistivity of the antenna is greater than 1GΩ.
To avoid electrostatic charge build-up, it must not be
rubbed or cleaned with solvents or a dry cloth.
Canada
I6
FCC and IC
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following conditions: This device may not cause
harmful interference. This device must accept any interference
received, including interference that may cause undesired
operation. This device must be installed to ensure a minimum
antenna separation distance of 20 cm from all persons.
Canada Intrinsically Safe
Certificate: CSA 1143113
Standards: CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No.
30-M1986, CAN/CSA C22.2 No. 94-M91, CSA
Std C22.2 No. 142-M1987, CSA Std C22.2 No.
157-92, ANSI/ISA 12.27.01-2003, CSA Std
C22.2 No. 60529:05
Markings: Intrinsically Safe Class I, Division 1; suitable for
Class 1, Zone 0, IIC, T3C; when connected per
Rosemount drawing 03151-1010; Type 4X
Ordinary Location Certification
Europe
As standard, the transmitter has been examined and tested to
determine that the design meets the basic electrical,
mechanical, and fire protection requirements by a nationally
recognized test laboratory (NRTL) as accredited by the Federal
Occupational Safety and Health Administration (OSHA).
I1
Installing Equipment in North America
Special Conditions for Safe Use (X):
1. The Rosemount 3051S Wireless and Rosemount 3051SMV
Wireless enclosure may be made of aluminum alloy and
given a protective polyurethane paint finish; however, care
should be taken to protect it from impact or abrasion if
located in a zone 0 area.
The US National Electrical Code (NEC) and the Canadian
Electrical Code (CEC) permit the use of Division marked
equipment in Zones and Zone marked equipment in Divisions.
The markings must be suitable for the area classification, gas,
and temperature class. This information is clearly defined in the
respective codes.
2. The surface resistivity of the antenna is greater than 1 GΩ.
To avoid electrostatic charge build-up, it must not be
rubbed or cleaned with solvents or dry cloth.
USA
I5
USA Intrinsically Safe (IS), Nonincendive (NI), and
Dust-Ignitionproof (DIP)
Certificate: FM 3027705
Standards: FM Class 3600 – 2011, FM Class 3610 – 2010,
FM Class 3611 – 2004, FM Class 3810 – 2005,
NEMA 250 – 2003
Markings: IS CL I, DIV 1, GP A, B, C, D; CL II, DIV 1, GP E, F,
G; CL III T4; CL 1, Zone 0 AEx ia IIC T4; NI CL 1,
DIV 2, GP A, B, C, D T4; DIP CL II, DIV 1, GP E, F,
G; CL III, T5; T4(–50 °C ≤ Ta ≤ +70 °C)/
T5(–50 °C ≤ Ta ≤ +85 °C); when connected per
Rosemount drawing 03151-1000; Type 4X
Emerson.com/Rosemount
ATEX Intrinsic Safety
Certificate: Baseefa13ATEX0127X
Standards: EN 60079-0:2012, EN 60079-11:2012
Markings:
II 1 G Ex ia IIC T4 Ga, T4(–60 °C ≤ Ta ≤ +70 °C)
International
I7
IECEx Intrinsic Safety
Certificate: IECEx BAS 13.0068X
Standards: IEC 60079-0:2011, IEC 60079-11:2011
Markings: Ex ia IIC T4 Ga, T4(–60 °C ≤ Ta ≤ +70 °C)
137
Rosemount 3051S Series
Special Conditions for Safe Use (X):
1. The Rosemount 3051S Wireless and Rosemount 3051SMV
Wireless enclosure may be made of aluminum alloy and
given a protective polyurethane paint finish; however, care
should be taken to protect it from impact or abrasion if
located in a zone 0 area.
2. The surface resistivity of the antenna is greater than 1GΩ.
To avoid electrostatic charge build-up, it must not be
rubbed or cleaned with solvents or dry cloth.
Brazil
I2
INMETRO Intrinsic Safety
Certificate: UL-BR 14.0760X
Standards: ABNT NBR IEC60079-0:2008 + Errata 1:2011,
ABNT NBR IEC60079-11:2009
Markings: Ex ia IIC T4 Ga, T4(–60 °C ≤ Ta ≤ +70 °C)
Special Condition for Safe Use (X):
1. See certificate.
China
I3
China Intrinsic Safety
Certificate: 3051S Wireless: GYJ161250X
3051SFX: GYJ11.1707X [Flowmeters]
Standards: GB3836.1-2010, GB3836.4-2010,
GB3836.20-2010
Markings: Ex ia IIC T4 Ga, T4(–60 ~ 70 °C)
Special Condition for Safe Use (X):
1. See appropriate certificate.
Note
Not currently available on the Rosemount 3051S MultiVariable
Wireless Transmitter.
138
October 2017
Japan
I4
TIIS Intrinsically Safe
Certificate: TC18649, TC18650, TC18657
Markings: Ex ia IIC T4, T4(–20 ~ 60 °C)
Note
Not currently available on the Rosemount 3051S MultiVariable
Wireless Transmitter.
EAC – Belarus, Kazakhstan, Russia
IM
EAC Intrinsic Safety
Certificate: RU C-US.AA87.B.00094
Markings: 0Ex ia IIC T4 Ga X (–60 °C ≤ Ta ≤ +70 °C)
Special Condition for Safe Use (X):
1. See certificate for special conditions.
Republic of Korea
IP
Korea Intrinsic Safety
Certificates: 12-KB4BO-0202X, 12-KB4BO-0203X
Markings: Ex ia IIC T4, (–60 °C ≤ Ta ≤ +70 °C)
Special Condition for Safe Use (X):
1. See certificate for special conditions.
Note
Not currently available on the Rosemount 3051S MultiVariable
Wireless Transmitter.
Combinations
KQ Combination of I1, I5, and I6
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Rosemount 3051SMV/3051SFx
Rev 1.18
European Directive Information
IE
A copy of the EU Declaration of Conformity can be found at the
end of the Quick Start Guide. The most recent revision of the EU
Declaration of Conformity can be found at
EmersonProcess.com/Rosemount.
Ordinary Location Certification
As standard, the transmitter has been examined and tested to
determine that the design meets the basic electrical,
mechanical, and fire protection requirements by a nationally
recognized test laboratory (NRTL) as accredited by the Federal
Occupational Safety and Health Administration (OSHA).
Canada
E6
Canada Explosionproof, Dust Ignition-proof, Division 2
Certificate: 1143113
Standards: CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No.
25-1966, CSA Std C22.2 No. 30-M1986, CSA
C22.2 No. 94.2-07, CSA Std C22.2 No.
213-M1987, CAN/CSA C22.2 60079-11:14,
CAN/CSA-C22.2 No. 61010-1-12, ANSI/ISA
12.27.01-2003, CSA Std C22.2 No. 60529:05
(R2010)
Markings: Explosionproof Class I, Division 1, Groups B, C,
D; Dust-Ignitionproof Class II, Division 1,
Groups E, F, G; Class III; suitable for Class I,
Division 2, Groups A, B, C, D; Type 4X
I6
Canada Intrinsically Safe
Certificate: 1143113
Standards: CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No.
25-1966, CSA Std C22.2 No. 30-M1986, CSA
C22.2 No. 94.2-07, CSA Std C22.2 No.
213-M1987, CAN/CSA C22.2 60079-11:14,
CAN/CSA-C22.2 No. 61010-1-12, ANSI/ISA
12.27.01-2003, CSA Std C22.2 No. 60529:05
(R2010)
Markings: Intrinsically Safe Class I, Division 1; suitable for
Class 1, Zone 0, IIC, T3C, Ta = 70 °C; when
connected per Rosemount drawing
03151-1207; Type 4X
IF
Canada FISCO Intrinsically Safe
Certificate: 1143113
Standards: CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No.
25-1966, CSA Std C22.2 No. 30-M1986, CSA
C22.2 No. 94.2-07, CSA Std C22.2 No.
213-M1987, CAN/CSA C22.2 60079-11:14,
CAN/CSA-C22.2 No. 61010-1-12, ANSI/ISA
12.27.01-2003, CSA Std C22.2 No. 60529:05
(R2010)
Markings: FISCO Intrinsically Safe Class I, Division 1;
Groups A, B, C, D; suitable for Class I, Zone 0;
T3C,
Ta = 70 °C; when installed per Rosemount
drawing 03151-1207; Type 4X
Installing Equipment in North America
The US National Electrical Code (NEC) and the Canadian
Electrical Code (CEC) permit the use of Division marked
equipment in Zones and Zone marked equipment in Divisions.
The markings must be suitable for the area classification, gas,
and temperature class. This information is clearly defined in the
respective codes.
USA
E5
US Explosionproof (XP) and Dust-Ignitionproof (DIP)
Certificate: FM16US0089X
Standards: FM Class 3600 – 2011, FM Class 3615 – 2006,
FM Class 3616 – 2011, 3810 – 2005,
ANSI/NEMA 250 – 2003
Markings: XP CL I, DIV 1, GP B, C, D; T5; DIP CL II, DIV 1,
GP E, F, G; CL III; T5(–50 °C ≤ Ta ≤ +85 °C);
Factory Sealed; Type 4X
I5
US Intrinsically Safe (IS) and Nonincendive (NI)
Certificate: FM16US0233
Standards: FM Class 3600 – 2011, FM Class 3610 – 2007,
FM Class 3611 – 2004, FM Class 3810 – 2005,
NEMA 250 – 1991
Markings: IS CL I, DIV 1, GP A, B, C, D; CL II, DIV 1, GP E, F,
G; Class III; Class 1, Zone 0 AEx ia IIC T4; NI CL 1,
DIV 2, GP A, B, C, D; T4(–50 °C ≤ Ta ≤ +70 °C)
when connected per Rosemount drawing
03151-1206; Type 4X
Note
Transmitters marked with NI CL 1, DIV 2 can be installed in
Division 2 locations using general Division 2 wiring methods or
Nonincendive Field Wiring (NIFW). See Drawing 03151-1206.
Emerson.com/Rosemount
US FISCO Intrinsically Safe
Certificate: FM16US0233
Standards: FM Class 3600 – 2011, FM Class 3610 – 2010,
FM Class 3611 – 2004, FM Class 3616 – 2006,
FM Class 3810 – 2005, NEMA 250 – 1991
Markings: IS CL I, DIV 1, GP A, B, C, D;
T4(–50 °C ≤ Ta ≤ +70 °C); when connected per
Rosemount drawing 03151-1006; Type 4X
139
Rosemount 3051S Series
October 2017
Europe
E1
IA
ATEX Flameproof
Certificate: KEMA 00ATEX2143X
Standards: EN 60079-0:2012, EN 60079-1:2007,
EN 60079-26:2007 (3051SFx models with RTD
are certified to EN 60079-0:2006)
Markings:
II 1/2 G Ex d IIC T6…T4 Ga/Gb,
T6(–60 °C ≤ Ta ≤ +70 °C), T5/T4(–60 °C ≤ Ta ≤
+80 °C)
Temperature class
T6
–60 °C to +70 °C
T5
–60 °C to +80 °C
T4
–60 °C to +120 °C
1. The device contains a thin wall diaphragm. Installation,
maintenance and use shall take into account the
environmental conditions to which the diaphragm will be
subjected. The manufacturer’s instructions for installation
and maintenance shall be followed in detail to assure
safety during its expected lifetime.
2. For information on the dimensions of the flameproof
joints, the manufacturer shall be contacted.
ATEX Intrinsic Safety
Certificate: Baseefa08ATEX0064X
Standards: EN 60079-0:2012, EN 60079-11:2012
Markings:
II 1 G Ex ia IIC T4 Ga, T4(–60 °C ≤ Ta ≤ +70 °C)
Parameter
HART
FOUNDATION SuperModule
Fieldbus
only
RTD (for 3051SFx)
HART
Fieldbus
Voltage Ui
30 V
30 V
7.14 V
30 V
30 V
Current Ii
300 mA
300 mA
300 mA
2.31 mA
18.24 mA
137 mW
Power Pi
Capacitance Ci
Inductance Li
1W
1.3 W
887 mW
17.32 mW
14.8 nF
0
0.11 μF
0
0.8 nF
0
0
0
0
1.33 mH
Special Conditions for Safe Use (X):
1. If the equipment is fitted with the optional 90 V transient
suppressor, it is incapable of withstanding the 500 V
isolation from earth test and this must be taken into
account during installation.
2. The enclosure may be made of aluminum alloy and given a
protective polyurethane paint finish; however, care should
be taken to protect it from impact or abrasion if located in
a Zone 0 environment.
140
FISCO
Parameter
Process temperature
Special Conditions for Safe Use (X):
I1
ATEX FISCO
Certificate: Baseefa08ATEX0064X
Standards: EN 60079-0:2012, EN 60079-11:2012
Markings:
II 1 G Ex ia IIC T4 Ga, T4(–60 °C ≤ Ta ≤ +70 °C)
Voltage Ui
17.5 V
Current Ii
380 mA
Power Pi
5.32 W
Capacitance Ci
0
Inductance Li
0
ND ATEX Dust
Certificate: BAS01ATEX1374X
Standards: EN 60079-0:2012, EN 60079-31:2009
Markings:
II 1 D Ex ta IIIC T105 °C T500 95 °C Da,
(–20 °C ≤ Ta ≤ +85 °C), Vmax = 42.4 V
Special Conditions for Safe Use (X):
1. Cable entries must be used which maintain the ingress
protection of the enclosure to at least IP66.
2. Unused cable entries must be filled with suitable blanking
plugs which maintain the ingress protection of the
enclosure to at least IP66.
3. Cable entries and blanking plugs must be suitable for the
ambient temperature range of the apparatus and capable
of withstanding a 7J impact test.
4. The SuperModule(s) must be securely screwed in place to
maintain the ingress protection of the enclosure(s).
N1 ATEX Type n
Certificate: Baseefa08ATEX0065X
Standards: EN 60079-0:2012, EN 60079-15:2010
Markings:
II 3 G Ex nA IIC T4 Gc, (–40 °C ≤ Ta ≤ 70 °C),
Vmax = 45 V
Special Condition for Safe Use (X):
1. If fitted with a 90 V transient suppressor, the equipment is
not capable of withstanding the 500 V electrical strength
test as defined in Clause 6.5.1 of EN 60079-15:2010. This
must be taken into account during installation.
International
E7
IECEx Flameproof and Dust
Certificate: IECEx KEM 08.0010X (Flameproof)
Standards: IEC 60079-0:2011, IEC 60079-1: 2007,
IEC 60079-26:2006 (3051SFx models with RTD
are certified to IEC 60079-0:2004)
Markings: Ex d IIC T6…T4 Ga/Gb, T6(–60 °C ≤ Ta ≤ +70 °C),
T5/T4(–60 °C ≤ Ta ≤ +80 °C)
Temperature class
Process temperature
T6
–60 °C to +70 °C
T5
–60 °C to +80 °C
T4
–60 °C to +120 °C
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Special Conditions for Safe Use (X):
1. The device contains a thin wall diaphragm. Installation,
maintenance and use shall take into account the
environmental conditions to which the diaphragm will be
subjected. The manufacturer’s instructions for installation
and maintenance shall be followed in detail to assure
safety during its expected lifetime.
2. For information on the dimensions of the flameproof
joints, the manufacturer shall be contacted.
Certificate: IECEx BAS 09.0014X (Dust)
Standards: IEC 60079-0:2011, IEC 60079-31:2008
Markings: Ex ta IIIC T105 °C T500 95 °C Da,
(–20 °C ≤ Ta ≤ +85 °C), Vmax = 42.4 V
2. Unused cable entries must be filled with suitable blanking
plugs which maintain the ingress protection of the
enclosure to at least IP66.
3. Cable entries and blanking plugs must be suitable for the
ambient temperature range of the apparatus and capable
of withstanding a 7J impact test.
IECEx Intrinsic Safety
Certificate: IECEx BAS 08.0025X
Standards: IEC 60079-0:2011, IEC 60079-11:2011
Markings: Ex ia IIC T4 Ga, T4(–60 °C ≤ Ta ≤ +70 °C)
FOUNDATION SuperModule
Fieldbus
only
7.14 V
HART
Fieldbus
30 V
30 V
30 V
Current Ii
300 mA
300 mA
300 mA
2.31 mA
18.24 mA
Power Pi
1W
1.3 W
887 mW
17.32 mW
137 mW
14.8 nF
0
0.11 μF
0
0.8 nF
0
0
0
0
1.33 mH
Special Conditions for Safe Use (X):
1. If the equipment is fitted with the optional 90 V transient
suppressor, it is incapable of withstanding the 500 V
isolation from earth test and this must be taken into
account during installation.
2. The enclosure may be made of aluminum alloy and given a
protective polyurethane paint finish; however, care should
be taken to protect it from impact or abrasion if located in
a Zone 0 environment.
IG
380 mA
Power Pi
5.32 W
Capacitance Ci
0
Inductance Li
0
Brazil
E2
INMETRO Flameproof
Certificate: UL-BR 15.0393X
Standards: ABNT NBR IEC 60079-0:2008 + Corrigendum
1:2011, ABNT NBR IEC 60079-1:2009 +
Corrigendum 1:2011, ABNT NBR IEC
60079-26:2008 + Corrigendum 1:2008
Markings: Ex d IIC T* Ga/Gb, T6(–60 °C ≤ Ta ≤ +70 °C),
T5/T4(–60 °C ≤ Ta ≤ +80 °C), IP66
1. The device contains a thin wall diaphragm. Installation,
maintenance and use shall take into account the
environmental conditions to which the diaphragm will be
subjected. The manufacturer's instructions for installation
and maintenance shall be followed in detail to assure
safety during its expected lifetime.
RTD (for 3051SFx)
30 V
Inductance Li
Current Ii
Special Conditions for Safe Use (X):
Voltage Ui
Capacitance Ci
17.5 V
1. If fitted with a 90 V transient suppressor, the equipment is
not capable of withstanding the 500 V electrical strength
test as defined in Clause 6.5.1 of IEC 60079-15:2010. This
must be taken into account during installation.
4. The Rosemount 3051S - SuperModule must be securely
screwed in place to maintain the ingress protection of the
enclosure.
HART
Voltage Ui
N7 IECEx Type n
Certificate: IECEx BAS 08.0026X
Standards: IEC 60079-0:2011, IEC 60079-15:2010
Markings: Ex nA IIC T5 Gc, (–40 °C ≤ Ta ≤ 70 °C)
1. Cable entries must be used which maintain the ingress
protection of the enclosure to at least IP66.
Parameter
FISCO
Special Condition for Safe Use (X):
Special Conditions for Safe Use (X):
I7
Parameter
2. For information on the dimensions of the flameproof
joints, the manufacturer shall be contacted.
I2
INMETRO Intrinsic Safety
Certificate: UL-BR 15.0357X
Standards: ABNT NBR IEC 60079-0:2008 + Addendum
1:2011, ABNT NBR IEC 60079-11:2009
Markings: Ex ia IIC T4 Ga (–60 °C ≤ Ta ≤ +70 °C)
Special Conditions for Safe Use (X):
1. If the equipment is fitted with the optional 90 V transient
suppressor, it is incapable of withstanding the 500 V
isolation from earth test and this must be taken into
account during installation.
IECEx FISCO
Certificate: IECEx BAS 08.0025X
Standards: IEC 60079-0:2011, IEC 60079-11:2011
Markings: Ex ia IIC T4 Ga, T4(–60 °C ≤ Ta ≤ +70 °C)
Emerson.com/Rosemount
141
Rosemount 3051S Series
October 2017
2. For processes with temperatures above 135 °C, the user
must assess whether the SuperModule temperature class
is suitable for such applications, because in this situation
there is a risk of the SuperModule temperature being
above T4.
7. During installation in a hazardous location, cable glands
and blanking plugs certified by state appointed inspection
bodies with Ex d IIC Gb or Ex d IIC Gb DIP A20 [Flowmeters]
IP66 type of protection should be used. Redundant cable
entries should be blocked with blanking plugs.
Input
RTD
Input
RTD
8. End users are not permitted to change any components,
but to contact the manufacturer to avoid damage to the
product.
Voltage Ui
30 V
30 V
30 V
30 V
9. Maintenance should be done when no explosive gas and
dust atmosphere is present.
Current Ii
300 mA
2.31 mA
300 mA
18.24 mA
Power Pi
1W
17.32 mW
1.3 W
137 mW
14.8 nF
0
0
0.8 nF
0
0
0
1.33 mH
HART
Fieldbus
Parameter
Capacitance Ci
Inductance Li
China
E3
China Flameproof and Dust Ignition-proof
Certificate: 3051SMV: GYJ14.1039X [Mfg USA, China,
Singapore]
3051SFx: GYJ11.1711X [Mfg USA, China,
Singapore]
Standards: 3051SMV: GB3836.1-2010, GB3836.2-2010,
GB3836.20-2010
3051SFx: GB3836.1-2010, GB3836.2-2010,
GB3836.20-2010, GB12476.1-2000
Markings: 3051SMV: Ex d IIC T6/T5 Ga/Gb
3051SFx: Ex d IIC T6/T5 Ga/Gb; DIP A20
TA 105 °C; IP66
Special Conditions for Safe Use (X):
1. Symbol “X” is used to denote specific conditions of use: For
information on the dimensions of the flameproof joints the
manufacturer shall be contacted.
2. The relationship between T code and ambient
temperature range are as follows:
T code
Ambient temperature range
T6
–50 °C ~ +65 °C
T5
–50 °C ~ +80 °C
3. The earth connection facility in the enclosure should be
connected reliably.
4. During installation, use and maintenance of the product in
explosive atmosphere, observe the warning “Do not open
cover when circuit is alive”. During installation, use, and
maintenance in explosive dust atmosphere, observe the
warning “Do not open when an explosive dust atmosphere
is present”.
5. During installation there should be no mixture harmful to
the housing.
10. During installation, use and maintenance of this product,
observe following standards:
GB3836.13-1997 “Electrical apparatus for explosive gas
atmospheres Part 13: Repair and overhaul for apparatus
used in explosive gas atmospheres”
GB3836.15-2000 “Electrical apparatus for explosive gas
atmospheres Part 15: Electrical installations in hazardous
area (other than mines)”
GB3836.16-2006 “Electrical apparatus for explosive gas
atmospheres Part 16: Inspection and maintenance of
electrical installation (other than mines)”
GB50257-1996 “Code for construction and acceptance of
electric device for explosion atmospheres and fire hazard
electrical equipment installation engineering”
I3
China Intrinsic Safety
Certificate: 3051SMV: GYJ14.1040X [Mfg USA, China,
Singapore]
3051SFx: GYJ11.1707X [Mfg USA, China,
Singapore]
Standards: 3051SMV: GB3836.1-2010, GB3836.4-2010,
GB3836.20-2010
3051SFx: GB3836.1/4-2010,
GB3836.20-2010, GB12476.1-2000
Markings: 3051SMV: Ex ia IIC T4 Ga
3051SFx: Ex ia IIC T4 Ga, DIP A20 TA105 °C
IP66
Special Conditions for Safe Use (X):
1. The enclosure may contain light metal, attention should
be taken to avoid ignition hazard due to impact or friction.
2. The apparatus is not capable of withstanding the 500V
electrical strength test defined in Clause 6.3.12 of
GB3836.4-2010.
3. Ambient temperature range: –60 °C ~ +70 °C
4. Intrinsically safe electric parameters:
Maximum
input
voltage:
Ui (V)
30
Maximum
Maximum
input
input power:
current:
Pi (W)
Ii (mA)
300
1.0
Maximum internal
parameters:
Ci (nF)
Li (μH)
14.8
0
6. During installation, use and maintenance in explosive dust
atmosphere, product enclosure should be cleaned to avoid
dust accumulation, but compressed air should not be
used.
142
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Republic of Korea
Maximum Maximum Maximum Maximum
external
output
output
output
EP Republic of Korea Flameproof [HART Only]
voltage:
current:
power: parameters:
Certificate: 12-KB4BO-0180X [Mfg USA], 11-KB4BO-0068X
Ui (V)
Ii (mA)
Pi (W) C (nF) L (μH)
[Mfg Singapore]
i
i
Markings: Ex d IIC T5 or T6
RTD
SuperModule
30
2.31
17.32
0
0
7.14
300
8871.0
110
0
5. The cables between this product and associated apparatus
should be shielded cables. The shield should be grounded
reliably in non-hazardous area.
6. The product should be used with Ex certified associated
apparatus to establish explosion protection system that
can be used in explosive gas atmospheres. Wiring and
terminals should comply with the instruction manual of
the product and associated apparatus.
7. End users are not permitted to change any components,
contact the manufacturer to avoid damage to the
product.
8. During installation in hazardous location, cable glands,
conduit, and blanking plugs certified by state-appointed
inspection bodies with DIP A20 IP66 type of protection
should be used. Redundant cable entries should be
blocked with blanking plugs.
9. During installation, use, and maintenance in explosive
dust atmosphere, observe the warning “Do not open
when an explosive dust atmosphere is present”.
10. Maintenance should be done when no explosive dust
atmosphere is present.
11. When installation, use and maintenance of this product,
observe following standards:
GB3836.13-1997 “Electrical apparatus for explosive gas
atmospheres Part 13: Repair and overhaul for apparatus
used in explosive gas atmospheres“
GB3836.15-2000 “Electrical apparatus for explosive gas
atmospheres Part 15: Electrical installations in hazardous
area (other than mines)”
GB3836.16-2006 “Electrical apparatus for explosive gas
atmospheres Part 16: Inspection and maintenance of
electrical installation (other than mines)”
GB50257-1996- “Code for construction and acceptance of
electric device for explosion atmospheres and fire hazard
electrical equipment installation engineering”
EAC – Belarus, Kazakhstan, Russia
EM Technical Regulation Customs Union (EAC) Flameproof
Certificate: RU C-US.AA87.B.00094
Markings: Ga/Gb Ex d IIC T6…T4 X
IM
Technical Regulation Customs Union (EAC) Intrinsic Safety
Certificate: RU C-US.AA87.B.00094
Markings: 0Ex ia IIC T4 Ga X
Japan
E4
Japan Flameproof
Certificate: TC19070, TC19071, TC19072, TC19073
Markings: Ex d IIC T6
Emerson.com/Rosemount
IP
Republic of Korea Intrinsic Safety [HART Only]
Certificate: 10-KB4BO-0021X [Mfg USA, SMMC]
Markings: Ex ia IIC T4
Combinations
K1 Combination of E1, I1, N1, and ND
K2 Combination of E2 and I2
K5 Combination of E5 and I5
K6 Combination of E6 and I6
K7 Combination of E7, I7, and N7
KA Combination of E1, I1, E6, and I6
KB Combination of E5, I5, E6, and I6
KC Combination of E1, I1, E5, and I5
KD Combination of E1, I1, E5, I5, E6, and I6
KM Combination of EM and IM
KP Combination of EP and IP
Additional certifications
SBS American Bureau of Shipping (ABS) Type Approval
Certificate: 00-HS145383
Intended Use: Measure gauge or absolute pressure of
liquid, gas or vapor applications on ABS
classed vessels, marine, and offshore
installations. [HART only]
SBV Bureau Veritas (BV) Type Approval
Certificate:
31910 BV
Requirements: Bureau Veritas Rules for the Classification of
Steel Ships
Application:
Class Notations: AUT-UMS, AUT-CCS,
AUT-PORT and AUT-IMS. [HART only]
SDN Det Norske Veritas (DNV) Type Approval
Certificate:
A-14186
Intended Use: Det Norske Veritas’ Rules for Classification of
Ships, High Speed and Light Craft, and Det
Norske Veritas’ Offshore Standards.
[HART only]
Application:
Location classes
Type
3051S
Temperature
D
Humidity
B
Vibration
A
EMC
A
Enclosure
D/IP66/IP68
143
Rosemount 3051S Series
October 2017
SLL Lloyds Register (LR) Type Approval
Certificate: 11/60002
Application: Environmental categories ENV1, ENV2, ENV3,
and ENV5. [HART only]
144
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Dimensional drawings
Figure 4. Transmitter with Coplanar Sensor Module and Flange
Plantweb housing
Junction box housing
Wireless housing
Front view
Front view
Front view
4.20
(107)
A
4.20
(107)
B
8.57
(218)
8.57
(218)
9.67
(246)
6.88
(174)
90°
11.16
(283)
4.20
(107)
9.67
(246)
A. Extended range external antenna
B. External antenna
Side view
4.51
(114)
Side view
Side view
3.45
(88)
3.55
(90.1)
6.71
(170)
6.05
(153)
7.72
(196)
8.57
(217)
9.67
(245)
6.55
(166)
6.55
(166)
6.55
(166)
Dimensions are in inches (millimeters).
Emerson.com/Rosemount
145
Rosemount 3051S Series
October 2017
Figure 5. Transmitter with Coplanar Sensor Module and Traditional Flange
Plantweb housing
Junction box housing
Wireless housing
Front view
Front view
Front view
A
B
6.88
(174)
9.30
(236)
9.30
(236)
3.40
(86)
1.10
(28)
11.16
(283) 7.81
4.20
(107)
3.40
(86)
90°
(198)
1.10
(28)
3.40
(86)
1.10
(28)
A. Extended range external antenna
B. External antenna
Side view
Side view
Side view
3.45
(88)
3.55
(90.1)
6.71
(170)
6.05
(155)
7.72
(196)
1.63
(41)
9.30
(236)
1.63
(41)
2.13
(54)
2.13
(54)
Dimensions are in inches (millimeters).
146
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Figure 6. Transmitter with In-line Sensor Module(1)
Plantweb housing
Junction box housing
Wireless housing
Front view
Front view
Front view
4.20
(107)
4.20
(107)
A
6.88
(174)
B
3.55
(90.1)
8.04
(204)
8.04
(204)
90°
11.16
(283)
4.20
(107)
A. Extended range external antenna
B. External antenna
Side view
5.17
(131) 4.51
(115)
Side view
Side view
3.45
(88)
6.88
(174)
6.71
(170)6.05
(155)
8.19
(208)
Dimensions are in inches (millimeters).
1.
For ranges 1A-4A, 1/2-in. NPT 316L SST process wetted connection. For detailed dimensions on other configurations, see Type I drawings at
Emerson.com/Rosemount.
Emerson.com/Rosemount
147
Rosemount 3051S Series
October 2017
Figure 7. Plantweb Housing, Junction Box Housing, and Quick Connect with In-line SuperModule Platform
4.55
(116)
4.20
(107)
3.45
(88)
1.50
(38)
2.57
(65)
7.97
(202)
8.04
(204)
6.22
(158)
1.37
(35)
A
2.40
(61)
A. I-flange process connector
Dimensions are in inches (millimeters).
148
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Figure 8. High Gain, Remote Mount Antenna (WN Option)
A
20.2 (513)
B
C
D
E
A. Antenna
B. Mounting bracket
C. Lightning arrester
D. 25 ft (7,6 m) cable
E. Min drip loop Ø12-in. (0,3 m)
Dimensions are in inches (millimeters).
Emerson.com/Rosemount
149
Rosemount 3051S Series
October 2017
Figure 9. Coplanar Mounting Configurations (B4 Bracket)
Pipe mount
Front view
Panel mount
Front view
Front view
4.51
(114)
2.58
(66)
6.15
(156)
2.81
(71)
6.25
(159)
3.54
(90)
4.73
(120)
Dimensions are in inches (millimeters).
Figure 10. Traditional Mounting Configurations
Pipe mount
Pipe mount (flat bracket)
Panel mount
10.71
(272)
2.62
(67)
8.10
(205)
8.10
(205)
0.93
(24)
3.40
(86)
2.62
(67)
3.40
(86)
4.85
(123)
7.70
(196)
Dimensions are in inches (millimeters).
150
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Figure 11. In-line Mounting Configurations (B4 Bracket)
Pipe mount
Panel mount
Front view
Side view
Side view
4.51
(114)
2.59
(65)
6.15
(156)
2.81
(71)
3.08
(78)
6.25
(159)
4.72
(120)
Dimensions are in inches (millimeters).
Figure 12. Remote Display Mounting Configurations (B4 Bracket)
Pipe mount
Front view
Panel mount
Side view
Side view
2.34
(59)
2.66
(68)
8.72
(221)
4.48
(114)
5.17
(131)
2.66
(68)
6.15
(156)
3.08
(78)
6.25
(158)
4.72
(120)
Dimensions are in inches (millimeters).
Emerson.com/Rosemount
151
Rosemount 3051S Series
October 2017
Figure 13. Rosemount 3051SFA Annubar Flowmeter(1)
Front view
Side view
Top view
D
C
B
A
Table 31. 3051CFA Annubar Flowmeter Dimensional Data
Sensor size
A (Max)
B (Max)
C (Max)
D (Max)
1
8.50(215,9)
17.10 (434,3)
8.66 (220,0)
7.00 (177,8)
2
11.00(279,4)
19.60 (497,8)
8.66 (220,0)
7.00 (177,8)
3
12.00 (304,8)
20.60 (523,2)
8.66 (220,0)
7.00 (177,8)
Dimensions are in inches (millimeters).
1.
152
The Pak-Lok Annubar model is available up to Class 600 ANSI (1440 psig at 100 °F [99 bar at 38 °C]).
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Figure 14. Rosemount 3051SFC Compact Orifice Flowmeter
Orifice plate front view
Orifice plate side view
Orifice plate top view
C
E
Primary element type code A
D
B
A
1.125 (28,58)
Primary element type code C and P
E
D
B
C
A
F
1.125 (28,58)
Dimensions are in inches (millimeters).
Table 32. Rosemount 3051SFC Compact Orifice Flowmeter Dimensional Data
Primary
element type
A
B
Transmitter
height
Type A
5.62
(143)
Transmitter
Height + A
8.53 (217)
7.75 (197) - closed 6.00 (152) - closed 10.0 (254) - closed
8.25 (210) - open 6.25 (159) - open 10.25 (260,3) - open
Type P and C
5.62
(143)
Transmitter
Height + A
7.70 (196)
7.75 (197) - closed 6.00 (152) - closed 10.2 (257,8) - closed Max of
8.25 (210) - open 6.25 (159) - open
10.4 (26,2) - open 7.2 (184)
C
D
E
F
N/A
Dimensions are in inches (millimeters).
Emerson.com/Rosemount
153
Rosemount 3051S Series
October 2017
Figure 15. Rosemount 3051SFP Integral Orifice Flowmeter
Front view
Bottom view
Side view
11.73
(297,9)
8.8
(223,46)
7.7
(195,6)
Flow
B.D.
A
5.3
(134,14)
B
Dimensions are in inches (millimeters).
Table 33. Rosemount 3051SFP Integral Orifice Flowmeter Dimensional Data
Line size
Dimension
/ -in. (15 mm)
1-in. (25 mm)
11/2-in. (40 mm)
J (Beveled/Threaded pipe ends)
12.54 (318,4)
20.24 (514,0)
28.44 (722,4)
J (RF slip-on, RTJ slip-on, RF-DIN slip on)
12.62 (320,4)
20.32 (516,0)
28.52 (724,4)
J (RF Class 150, weld neck)
14.37 (364,9)
22.37 (568,1)
30.82 (782,9)
J (RF Class 300, weld neck)
14.56 (369,8)
22.63 (574,7)
31.06 (789,0)
J (RF Class 600, weld neck)
14.81 (376,0)
22.88 (581,0)
31.38 (797,1)
K (Beveled/Threaded pipe ends)
5.74 (145,7)
8.75 (222,2)
11.91 (302,6)
K (RF slip-on, RTJ slip-on, RF-DIN slip on)(1)
5.82 (147,8)
8.83 (224,2)
11.99 (304,6)
K (RF Class 150, weld neck)
7.57 (192,3)
10.88 (276,3)
14.29 (363,1)
K (RF Class 300, weld neck)
7.76 (197,1)
11.14 (282,9)
14.53 (369,2)
1 2
1.
154
Downstream length shown here includes plate thickness of 0.162-in. (4,11 mm).
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Figure 16. Rosemount 3051S Scalable Level Transmitter with FF Seal(1)(2)
Coplanar
In-line
5.17
(131)
4.20
(107)
4.51
(114)
4.20
(107)
5.17
(131)
8.04
(204)
8.57
(217,7)
1.50
(38)
3.62
(92)
+ Direct Mount
Extension Length
Dimensions are in inches (millimeters).
Figure 17. Rosemount 3051S Scalable Level Transmitter with EF Seal(1)
Coplanar
5.17
4.51 (131)
(114)
In-line
4.20
(107)
8.57
(217,7)
4.20
(107)
5.17
(131)
8.04
(204)
1.50
(38)
3.62
(92)
+ Direct Mount
Extension Length
Dimensions are in inches (millimeters).
1.
Seal dimensions and pressure ratings can be found in the Rosemount DP Level Transmitters and 1199 Remote Seals Product Data Sheet.
2.
Lower housing (flushing ring) is available with FFW style flange.
Emerson.com/Rosemount
155
Rosemount 3051S Series
October 2017
Figure 18. Rosemount 3051S Scalable Level Transmitter with RF Seal(1)
Coplanar
In-line
5.17
(131)
5.17
(131)
4.20
(107)
4.20
(107)
4.51
(114)
8.04
(204)
8.57
(217,7)
1.50
(38)
3.62
(92)
+ Direct Mount
Extension Length
Dimensions are in inches (millimeters).
Figure 19. Rosemount 3051S Scalable Level Transmitter with RT Seal(2)
Coplanar
In-line
4.51
(114)
5.17
(131)
4.20
(107)
4.20
(107)
4.51
(114)
8.57
(217,7)
8.04
(204)
1.50
(38)
3.62
(92)
+ Direct Mount
Extension Length
Dimensions are in inches (millimeters).
1.
Seal dimensions and pressure ratings can be found in the Rosemount DP Level Transmitters and 1199 Remote Seals Product Data Sheet.
2.
Seal dimensions and pressure ratings can be found in the Rosemount DP Level Transmitters and 1199 Remote Seals Product Data Sheet.
156
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Figure 20. Rosemount 3051S Scalable Level Transmitter with SS Seal(1)
Coplanar
In-line
5.17
(131)
4.20
(107)
5.17
(131)
4.51
(114)
4.20
(107)
8.57
(217,7)
8.04
(204)
1.50 (38)
3.62
(92)
+ Direct Mount
Extension Length
Dimensions are in inches (millimeters).
Emerson.com/Rosemount
157
Rosemount 3051S Series
October 2017
Figure 21. Rosemount 3051S Scalable Level Transmitter with SC Seal
Coplanar
In-line
5.17
(131)
5.17
(131)
4.51
(114)
4.20
(107)
4.20
(107)
8.04
(204)
8.57
(217,7)
1.50
(38)
3.62
(92)
+ Direct Mount
Extension Length
Dimensions are in inches (millimeters).
158
Emerson.com/Rosemount
October 2017
Rosemount 3051S Series
Figure 22. Rosemount 3051S Scalable Level Transmitter with Thermal Range Expander
Coplanar
5.17
(131,3)
In-line
4.20
(106,7)
4.20
(106,7)
5.17
(131,3)
7.84
(199,1)
8.36
(212,3)
13.51
(343,2)
1.50
(38,1)
7.64
(194,2)
Dimensions are in inches (millimeters).
Emerson.com/Rosemount
159
Rosemount 3051S Series
October 2017
Accessories
Rosemount Engineering Assistant (EA)
software packages
The Rosemount Engineering Assistant software supports flow
configuration for the Rosemount 3051SMV and Rosemount
3051S FOUNDATION Fieldbus fully compensated mass flow block
(H01 option). The package is available with or without modem
and connecting cables. All configurations are packaged
separately. For best performance of the EA software, the
following computer hardware and software is recommended:
Note
Engineering Assistant version 6.1 or later requires the use of
Microsoft®.NET Framework version 2.0 or later. If.NET version
2.0 is not currently installed, the software will be automatically
installed during the Engineering Assistant installation.
Microsoft.NET version 2.0 requires an additional 200 MB of disk
space.
Minimum system requirements for Engineering
Assistant 5.5.1 for the Rosemount 3051S and
Rosemount 3051SMV FOUNDATION Fieldbus with
fully compensated mass flow block

Intel® Core™ Duo, 2.4 GHz

Operating System: Windows™ 7, 32- or 64-bit

600 MB of available hard disk space

USB port (for use with fieldbus interface)
Minimum system requirements for Engineering
Assistant 6 for the Rosemount 3051SMV HART
device
 Pentium®-grade Processor: 500 MHz or faster

Operating System: Microsoft Windows 2000 (32-bit),
Windows XP Professional (32-bit), Windows 7, or Windows 8

256 MB RAM

100 MB of available hard disk space

RS232 serial port or USB port (for use with HART modem)

CD-ROM
160
Engineering Assistant software packages
Code
EA
Product description
Engineering Assistant Software Program
Software media
2
EA Rev. 5 (Compatible with Rosemount 3051SMV
FOUNDATION Fieldbus, Rosemount 3095, Rosemount
3051S FOUNDATION Fieldbus, and Rosemount 333)
3
EA Rev. 6 (Compatible with Rosemount 3051SMV
HART only)
Language
E
English
Modem and connecting cables
0
None
H
Serial port HART modem and cables
B
USB port HART modem and cables
C
FOUNDATION Fieldbus PCM-CIA Interface card and cables
License
N1
Single PC license
N2
Site license
Typical model number:
EA
2
E
0
N1
Accessories
Part number
Item description
Serial port HART modem and cables only
03095-5105-0001
USB port HART modem and cables only(1)
03095-5105-0002
FOUNDATION Fieldbus PCM-CIA Interface
card and cables only
03095-5108-0001
Long-life power module for Wireless option
1.
701PBKKF
Supported by SNAP-ON™ EA with AMS Device Manager version 6.2 or higher.
Emerson.com/Rosemount
October 2017
Emerson.com/Rosemount
Rosemount 3051S Series
161
Rosemount 3051S Series
Product Data Sheet
00813-0100-4801, Rev UG
October 2017
Global Headquarters
Emerson Automation Solutions
6021 Innovation Blvd.
Shakopee, MN 55379, USA
+1 800 999 9307 or +1 952 906 8888
+1 952 949 7001
[email protected]
North America Regional Office
Emerson Automation Solutions
8200 Market Blvd.
Chanhassen, MN 55317, USA
+1 800 999 9307 or +1 952 906 8888
+1 952 949 7001
[email protected]
Linkedin.com/company/Emerson-Automation-Solutions
Twitter.com/Rosemount_News
Latin America Regional Office
Emerson Automation Solutions
1300 Concord Terrace, Suite 400
Sunrise, FL 33323, USA
+1 954 846 5030
+1 954 846 5121
[email protected]
Facebook.com/Rosemount
Youtube.com/user/RosemountMeasurement
Google.com/+RosemountMeasurement
Europe Regional Office
Emerson Automation Solutions Europe GmbH
Neuhofstrasse 19a P.O. Box 1046
CH 6340 Baar
Switzerland
+41 (0) 41 768 6111
+41 (0) 41 768 6300
[email protected]
Asia Pacific Regional Office
Emerson Automation Solutions Asia
1 Pandan Crescent
Singapore 128461
+65 6777 8211
+65 6777 0947
[email protected]
Middle East and Africa Regional Office
Emerson Automation Solutions
Emerson FZE P.O. Box 17033
Jebel Ali Free Zone - South 2
Dubai, United Arab Emirates
+971 4 8118100
+971 4 8865465
[email protected]
Standard Terms and Conditions of Sale can be found on the Terms and
Conditions of Sale page.
The Emerson logo is a trademark and service mark of Emerson Electric Co.
Plantweb, Annubar, Coplanar, ERS, Instrument Toolkit, MultiVariable,
Saturn, Scalable, SmartPower, SuperModule, THUM Adapter,
Tuned-System, UltraTherm, SNAP-ON, Rosemount, and Rosemount
logotype are trademarks of Emerson.
HART and WirelessHART are registered trademarks of the FieldComm
Group.
FOUNDATION Fieldbus is a trademark of the FieldComm Group.
eurofast and minifast are registered trademarks of TURCK.
Microsoft is a registered trademark of Microsoft Corporation in the United
States and other countries.
Windows is a trademark of Microsoft Corporation in the United States and
other countries.
SYLTHERM is a trademark of Dow Corning Corporation.
Neobee is a registered trademark of Stepan Specialty Products, LLC.
NACE is a registered trademark of NACE International.
National Electrical Code is a registered trademark of National Fire
Protection Association, Inc.
NEMA is a registered trademark and service mark of the National
Electrical Manufacturers Association.
GRAFOIL is a registered trademark of GrafTech International Holdings Inc.
Fluorinert is a trademark of 3M.
Intel is a registered trademark of Intel Corporation in the U.S. and/or other
countries.
Intel Core is trademark of Intel Corporation in the U.S. and/or other
countries.
Pentium is a registered trademark of the Intel Corporation.
3-A is a registered trademark of 3-A Sanitary Standards, Inc.
Thermo-Tork is a registered trademark of Armstrong World Industries,
Inc. Corporation.
All other marks are the property of their respective owners.
© 2017 Emerson. All rights reserved.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project