Showtec Quick DMX Rack DMX Rack User manual
Below you will find brief information for DMX Rack Quick Quick DMX Rack. The Showtec Quick DMX Rack is a stand-alone DMX interface that can store up to 16 different DMX files, making it suitable for fixed installations. It is easy to use, just connect it to a PC, program your DMX files using the Quick DMX software, save them to memory, and play back the shows. The Quick DMX Rack also supports DMX patching, allowing you to control devices on the DMX data link using an external fader desk.
Advertisement
Advertisement
MANUAL
ENGLISH
Quick DMX Rack V1
Ordercode: 50054
Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands
Quick DMX Rack
Table of contents
Ordercode: 50054
1
Quick DMX Rack
Warning
Unpacking Instructions
Immediately upon receiving this product, carefully unpack the carton and check the contents to ensure that all parts are present, and have been received in good condition. Notify the dealer immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing.
Your shipment includes:
Quick DMX Rack with a 9V power adapter
User manual
Safety Instructions
Every person involved with the installation, operation and maintenance of this device has to:
be qualified
follow the instructions of this manual
Before your initial start-up, please make sure that there is no damage caused by transportation. Should there be any, consult your dealer and do not use the device.
To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual.
Please consider that damages caused by manual modifications to the device are not subject to warranty.
This device contains no user-serviceable parts. Refer servicing to qualified technicians only.
Ordercode: 50054
2
Quick DMX Rack
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the device.
Never let the power cord come into contact with other cables! Handle the power cord and all connections with the mains with particular caution!
Never remove warning or informative labels from the unit.
Never use anything to cover the ground contact.
Never leave any cables lying around.
Never leave various parts of the packaging (plastic bags, polystyrene foam, nails, etc.) within children’s reach, as they are potential sources of danger.
Do not open the device and do not modify the device.
Do not connect this device to a dimmer pack.
Do not shake the device. Avoid brute force when installing or operating the device.
Do not switch the device on and off in short intervals, as this would reduce the system’s life.
Do not touch the device’s housing bare-handed during its operation (housing becomes hot).
Only use device indoors, avoid contact with water or other liquids.
Only operate the device after having familiarized with its functions.
Avoid flames and do not put close to flammable liquids or gases.
Always keep case closed while operating.
Always disconnect power from the mains, when device is not used or before cleaning! Only handle the power cord by the plug. Never pull out the plug by tugging the power cord.
Make sure that the device is not exposed to extreme heat, moisture or dust.
Make sure that the available voltage is not higher than stated on the rear panel.
Make sure that the power cord is never crimped or damaged. Check the device and the power cord from time to time.
If the external cable is damaged, it has to be replaced by a qualified technician.
If device is dropped or struck, disconnect mains power supply immediately. Have a qualified engineer inspect for safety before operating.
If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature.
If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely
(preferably in the original packing material), and return it to your Showtec dealer for service.
For adult use only. The device must be installed out of the reach of children. Never leave the unit running unattended.
For replacement use fuses of same type and rating only.
The user is responsible for correct positioning and operating of the Quick DMX Rack. The manufacturer will not accept liability for damages caused by the misuse or incorrect installation of this device.
This device falls under protection class I. Therefore it is essential to connect the yellow/green conductor to earth.
Repairs, servicing and electric connection must be carried out by a qualified technician.
WARRANTY: Till one year after date of purchase.
Operating Determinations
This system is not designed for permanent operation. Consistent operation breaks will ensure that the system will serve you for a long time without defects.
If this system is operated in any other way, than the one described in this manual, the product may suffer damages and the warranty becomes void.
Any other operation may lead to dangers like short-circuit, burns, electric shock, etc.
You endanger your own safety and the safety of others!
Improper installation can cause serious damage to people and property !
Ordercode: 50054
3
Quick DMX Rack
Connection with the mains
Connect the device to the mains with the power-plug.
Always check if the right color cable is connected to the right place.
International
L
EU Cable
BROWN
UK Cable
RED
US Cable
YELLOW/COPPER
N
BLUE
YELLOW/GREEN
BLACK
GREEN
SILVER
GREEN
Pin
PHASE
NEUTRAL
PROTECTIVE GROUND
Make sure that the device is always properly connected to the earth!
Improper installation can cause serious injuries and/or damage of property!
Return Procedure
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility.
Call Highlite 0031-455667723 or mail [email protected]
and request an RMA prior to shipping the fixture.
Be prepared to provide the model number, serial number and a brief description of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use.
Note: If you are given an RMA number, please include the following information on a piece of paper inside the box:
01) Your name
02) Your address
03) Your phone number
04) A brief description of the symptoms
Claims
The client has the obligation to check the delivered goods immediately upon delivery for any shortcomings and/or visible defects, or perform this check after our announcement that the goods are at their disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be reported to the carrier upon receipt of merchandise.
It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping. Transportation damage has to be reported to us within one day after receipt of the delivery.
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless otherwise agreed in writing.
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the invoice. After this period complaints will not be handled anymore.
Complaints will only then be considered if the client has so far complied with all parts of the agreement, regardless of the agreement of which the obligation is resulting.
Ordercode: 50054
4
Quick DMX Rack
Description of the device
Features
The Showtec Quick DMX Rack is a stand-alone interface which can store up to 16 different DMX files.
It makes the device suitable for fixed installations. In order to edit DMX files, connection with Quick DMX software is required.
Input voltage: 9V DC, 300mA power adapter (included), USB
Memory: 16 slots
Control protocol: DMX-512
DMX channels: 512 channels
Housing: Metal & flame-retardant plastic
Connections: 3-pin DMX IN/OUT, USB B-type IN, power adapter IN
Dimensions: 483 x 78 x 44,5 mm (LxWxH)
19” x 1 HE
Weight: 1,3 kg
Frontside
Fig. 01
01) LED indicators (POWER/PC LINK/ DMX INPUT)
02) Memory buttons (1-16)
03) Memory LED indicators (1-16)
Backside
04) 3-pin DMX signal connector IN
05) 3-pin DMX signal connectors OUT
06) USB B-type IN
07) Power selector (USB/9V adapter)
08) 9V DC power adapter IN
Installation
Remove all packing materials from the Quick DMX Rack. Check if all foam and plastic padding is removed. Connect all cables.
Do not supply power before the whole system is set up and connected properly.
Always disconnect from electric mains power supply before cleaning or servicing.
Damages caused by non-observance are not subject to warranty.
Fig. 02
Ordercode: 50054
5
Quick DMX Rack
Set Up and Operation
Follow the directions below, as they pertain to your preferred operation mode.
Before plugging the unit in, always make sure that the power supply matches the product specification voltage. Do not attempt to operate a 120V specification product on 230V power, or vice versa.
Connect the device to the main power supply.
Power Selector
01) Move the power selector (07) to the left for the Quick DMX Rack to be powered via USB. Connect the device to your PC by plugging one end of the included USB cable into the USB connector on your PC and the other end into the USB connector on the device (06).
02) Move the power selector (07) to the right for the Quick DMX Rack to be powered with the 9V power adapter. Plug the included 9V adapter into an appropriate power supply and the other end of the cable into the 9V input connector (08).
Saving DMX Files to the Memory Buttons
01) Install Quick DMX software:
02) Download the software via this link: Software Quick DMX
03) For further information, download the user manual: Quick DMX software manual
04) Start Quick DMX software, program and save a desired show (scene/chase/pixel/generator).
Ordercode: 50054
6
Quick DMX Rack
05) Click on “StandAlone” tab. The display will show:
06) Click on one of the numbers (1-16) in order to choose the desired memory button.
07) Right-click on the timeline and choose “Add light scene,” “Add Generator scene” or “Add Pixels scene.” The display will show:
Ordercode: 50054
7
Quick DMX Rack
08) Select the previously created DMX file. It will now appear on the timeline:
09) Use drag-and-drop method to move the scene/chase/pixel/generator across the timeline.
10) Edit the following options:
Zones: The Quick DMX Rack handles the programmed DMX files using the LTP principle (Latest
Takes Priority). This means that only one DMX file can be played at a time. In order to be able to play multiple DMX files at the same time, assign them to different zones. The Quick DMX Rack offers 4 zones to choose from. Once you have assigned the zones to the desired memory buttons, the memory buttons in the software will light in one of the following colors: zone #1
(orange), zone #2 (blue), zone #3 (pink) and zone #4 (yellow).
Auto start: When this option is checked, the scene/chase will start automatically upon start-up of the Quick DMX Rack, without triggering.
Enable calendar “on” trigger: Click on “Edit” to set the starting time of the scene/chase.
Enable calendar “off” trigger: Click on “Edit” to set the stopping time of the scene/chase.
11) Repeat steps 3-9 in order to assign DMX files to the remaining memory buttons.
12) Once you have assigned all the scenes/chases to the desired buttons, click on “Upload Data,” in order to export data to the Quick DMX Rack and wait until the process is finished.
Ordercode: 50054
8
Quick DMX Rack
13) Press the desired 1-16 memory buttons (02) in order to trigger the programmed scenes/chases.
While assigning DMX files to the memory buttons, always start with button #1 and proceed with buttons #2, 3, 4, up to button #16.
It is NOT RECOMMENDED to assign DMX files to random buttons.
In such case, some DMX files WILL NOT function properly.
Patching DMX Input
If you have an external fader desk and would like to operate a device present on the DMX data link, assigned to a channel which cannot be reached by means of your fader desk, the Quick DMX Rack gives you the possibility to patch DMX input to the desired DMX outputs.
01) Start Quick DMX software and click on “File.”
02) Select “Hard Midi and DMX patch (obsolete).” The display will show:
03) In “Input,” set the fader which you would like to assign to a particular channel(s).
04) Set “Priority mode” to DMX input.
Ordercode: 50054
9
Quick DMX Rack
05) In “Outputs,” insert the number of the channel(s) which you want to be triggered by the selected fader.
06) Click on “Add” to create the patch (e.g. fader #1 should trigger the DMX channels #1, 2, 3, 4, 5, 6 and 7). The display will show:
07) If you now move the fader #1 on your fader desk, the DMX channels #1, 2, 3, 4, 5, 6 and 7 will be triggered.
CAUTION: This function will work only when Quick DMX is active.
If you close the software, the patch will stop working.
For more information on other available functions, please read the Quick DMX software documentation.
Quick DMX (manual):
Download via link: Quick DMX software manual
Ordercode: 50054
10
Quick DMX Rack
Control Modes
DMX Control
01) Fasten the device to a 19-inch rack.
02) Use a 3-pin XLR cable to connect the Quick DMX Rack and other devices.
03) Connect the Quick DMX Rack’s "in" socket to a light controller. Connect the Quick DMX Rack to a
PC by means of a USB cable.
04) Link the units as shown in fig. 03.
05) Supply electric power: Plug the included power adapter into proper electric power supply socket.
Do not supply power before the whole system is set up and connected properly.
DMX Setup
Ordercode: 50054
Note : Link all cables before connecting electric power
11
Fig. 03
Quick DMX Rack
Data Cabling
To link fixtures together, you must obtain data cables. You can purchase DAP Audio certified DMX cables directly from a dealer/distributor or construct your own cable. If you choose to create your own cable, please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic interference.
DAP Audio DMX Data Cables
• DAP Audio Basic microphone cable for allround use. bal. XLR/M 3-pin > XLR/F 3-pin.
Ordercode FL01150 (1,5 m), FL013 (3 m), FL016 (6 m), FL0110 (10 m), FL0115 (15 m), FL0120 (20 m).
• DAP Audio X-type data cable XLR/M 3-pin > XLR/F 3-pin. Ordercode FLX0175 (0,75 m),
FLX01150 (1,5 m), FLX013 (3 m), FLX016 (6 m), FLX0110 (10 m).
• DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by
Neutrik®. Ordercode FL71150 (1,5 m), FL713 (3 m), FL716 (6 m), FL7110 (10 m).
• DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by
Neutrik®. Ordercode FL7275 (0,75 m), FL72150 (1,5 m), FL723 (3 m), FL726 (6 m), FL7210 (10 m).
• DAP Audio 110 Ohm cable with digital signal transmission. Ordercode FL0975 (0,75 m),
FL09150 (1,5 m), FL093 (3 m), FL096 (6 m), FL0910 (10 m), FL0915 (15 m), FL0920 (20 m).
Maintenance
The Showtec Quick DMX Rack requires almost no maintenance. However, you should keep the unit clean. Disconnect the mains power supply, and then wipe the cover with a damp cloth. Do not immerse in liquid. Do not use alcohol or solvents.
Keep connections clean. Disconnect electric power, and then wipe the DMX connections with a damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying electric power.
Troubleshooting
No Function
This troubleshooting guide is meant to help solve simple problems.
If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit operates properly, do not carry out following steps.
01) If the device does not operate properly, unplug the device.
02) Check the power from the wall, all cables etc.
03) If all of the above appears to be O.K., plug the unit in again.
04) If you are unable to determine the cause of the problem, do not open the Quick DMX Rack, as this may damage the unit and the warranty will become void.
05) Return the Quick DMX Rack to your Showtec dealer.
No Response to DMX
Suspect the DMX cable or connectors, a distributor malfunction, a controller malfunction, a light effect
DMX card malfunction.
01) Check the DMX setting. Make sure that DMX addresses are correct.
02) Check the DMX cable: Unplug the unit; change the DMX cable; then reconnect to electrical power.
Try your DMX control again.
03) Determine whether the distributor, controller or light effect is at fault. If the distributor or controller does not operate properly, take the distributor or controller in for repair. Otherwise, take the DMX cable and the light effect to a qualified technician.
Ordercode: 50054
12
Quick DMX Rack
Product Specifications
Model:
Input voltage:
Memory:
DMX channels:
Control protocol:
Connections:
Housing:
Dimensions:
Showtec Quick DMX Rack
9V DC, 300mA power adapter (included), USB
16 slots
512 channels
DMX-512
3-pin DMX IN/OUT, USB B-type IN, power adapter IN
Metal & flame-retardant plastic
483 x 78 x 44,5 mm (LxWxH)
19” x 1 HE
1,3 kg Weight:
Design and product specifications are subject to change without prior notice.
Website: www.Showtec.info
Email: [email protected]
Ordercode: 50054
13
Quick DMX Rack
Ordercode: 50054
14
©2017 Showtec
Advertisement
Key Features
- Stores up to 16 DMX files
- Suitable for fixed installations
- Simple to use
- DMX patching
- Supports USB connection