STANDBY GENERATORS
17 kW
AIR-COOLED GENERATOR SETS
Standby Power Rating
Model 006282-0 (Steel - Dark Gray) - 17 kW 60 Hz
Photograph may not represent actual content.
INCLUDES
• PrecisionPower™ Electrical Technology
• WhisperCheck™ Exercise
• Two Line LCD Multilingual Digital Controller
(English/Spanish/French/Portuguese)
• Composite Mounting Pad
• Electronic Governor
• Sound Attenuated Enclosure
• Natural Gas or LP Gas Operation
• External Main Circuit Breaker, System Status
& Maintenance Interval LED Indicators
• 3 Year Limited Warranty
• Flexible Fuel Line Connector
• Capability to be installed within 18” (457 mm) of a building*
• GFCI Duplex Outlet
• 200 amp CSA approved service rated switch
*Only if located away from doors, windows and fresh air intakes, and unless
otherwise directed by local codes.
FEATURES
¡ INNOVATIVE DESIGN &
PROTOTYPE TESTING are key
components of our success in “IMPROVING
POWER BY DESIGN.” But it doesn’t stop
there. Total commitment to component
testing, reliability testing, environmental
testing, destruction and life testing, plus
testing to applicable CSA, NEMA, EGSA,
and other standards, allows you to choose
Honeywell generators with the confidence
that these systems will provide superior
performance.
¡
TEST CRITERIA
w PROTOTYPE TESTED
w SYSTEM TORSIONAL TESTED
w NEMA MG1-22 EVALUATION
w MOTOR STARTING ABILITY
¡ PrecisionPower™ ELECTRICAL
TECHNOLOGY Superior harmonics and
sine wave form produce less than 5% Total
Harmonic Distortion for utility quality power.
This allows confident operation of sensitive
electronic equipment and micro-chip based
appliances, such as variable speed HVAC.
¡ SOLID-STATE, FREQUENCY
COMPENSATED VOLTAGE
REGULATION This state-of-the-art power
maximizing regulation system is standard
on all Honeywell models. It provides
optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR
STARTING CAPABILITY by electronically
torque-matching the surge loads to the
engine. Digital voltage regulation at +/- 1%.
¡
SINGLE SOURCE SERVICE
RESPONSE from our extensive dealer
network provides parts and service knowhow for the entire unit, from the engine to
the smallest electronic component.
¡ H
oneywell TRANSFER SWITCHES
The Honeywell generator line includes its
own transfer systems and controls for total
system compatibility.
17 kW
AIR-COOLED GENERATOR SETS
ENGINE
• Generac OHVI® design
Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings
help the engine run cooler, reducing oil consumption resulting in longer engine life.
• “Spiny-lok” cast iron cylinder walls
Rigid construction and added durability provide long engine life.
• Electronic ignition/spark advance
These features combine to assure smooth, quick starting every time.
• Full pressure lubrication system
Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life.
Now featuring up to a 2 year/200 hour oil change interval.
• Low oil pressure shutdown system
Shutdown protection prevents catastrophic engine damage due to low oil.
• High temperature shutdown
Prevents damage due to overheating.
GENERATOR
• Revolving field
Allows for smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
•Skewed stator
Produces a smooth output waveform for compatibility with electronic equipment.
• Displaced phase excitation
Maximizes motor starting capability.
• Automatic voltage regulation
Regulates the output voltage to ±1% prevents damaging voltage spikes.
• UL 2200 listed
For your safety.
TRANSFER SWITCH
• Fully automatic
Transfers your vital electrical loads to the energized source of power.
• Remote mounting
Mounts near your existing distribution panel for simple, low-cost
CONTROLS
• Auto/Manual/Off illuminated buttons
Selects the operating mode and provides easy, at-a-glance status indication in any condition.
• Sealed, raised buttons
Smooth, weather-resistant user interface for programming and operations.
• Utility voltage sensing
Constantly monitors utility voltage, setpoints 60% dropout, 80% pick-up, of standard voltage.
• Generator voltage sensing
Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
• Utility interrupt delay
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5
seconds by a qualified dealer.
• Engine warm-up
Ensures engine is ready to assume the load, setpoint approximately 5 seconds.
• Engine cool-down
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
• Programmable seven day exerciser
Operates engine to prevent oil seal drying and damage between power outages by running the generator for 12
minutes every week.
• Smart battery charger
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
• Main line circuit breaker
Protects generator from overload.
• Electronic governor
Maintains constant 60 Hz frequency.
UNIT
• Weather protective enclosure
Provides protection against mother nature and can withstand winds up to 150mph. Hinged key locking roof panel
for security. Lift-out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy
paint for added durability.
• Enclosed critical grade muffler
Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
• Small, compact, attractive
Makes for an easy, eye appealing installation.
INSTALLATION SYSTEM
• 1 ft (305 mm) flexible fuel line connector
• Composite mounting pad
2
www.honeywellgenerators.com
Easy installation.
GENERATOR
Rated Maximum Continuous Power Capacity (LP)
Rated Maximum Continuous Power Capacity (NG)
Rated Voltage
Rated Maximum Continuous Load Current – 240 V (LP/NG)
Total Harmonic Distortion
Main Line Circuit Breaker
Phase
Number of Rotor Poles
Rated AC Frequency
Power Factor
Battery Requirement (not included)
Unit Weight (lb/kg)
Dimensions (L x W x H) in./mm
Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load**
Sound output in dB(A) at 23 ft (7 m) with generator in WhisperCheck™
low speed exercise mode**
Model 006282-0 (17 kW)
17,000 Watts*
16,000 Watts*
240
70.8/66.6
Less than 5%
65 Amp
1
2
60 Hz
1.0
Group 26R, 12 Volts and 525 CCA Minimum
471/213.6
48 x 25 x 29/1218 x 638 x 732
66
60
ENGINE
Type of Engine
GENERAC OHVI V-TWIN
Number of Cylinders
2
Displacement
992 cc
Cylinder Block
Aluminum w/ Cast Iron Sleeve
Valve Arrangement
Overhead Valve
Ignition System
Solid-state w/ Magneto
Governor System
Electronic
Compression Ratio
9.5:1
Starter
12 Vdc
Oil Capacity Including Filter
Approx. 1.9 qt/1.8 L
Operating rpm
3,600
Fuel Consumption
Natural Gas ft³/hr (m³/hr)
1/2 Load
193 (5.47)
Full Load
312 (8.83)
3
Liquid Propane
ft /hr (gal/hr) [l/hr]
1/2 Load
72.4 (1.99) [7.53]
Full Load
130 (3.57) [13.53]
Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7” water column (7-13 mm mercury) for natural gas,
10-12” water column (19-22 mm mercury) for LP gas. For Btu content, multiply ft3/hr x 2500 (LP) or ft3/hr x 1000 (NG). For Megajoule content, multiply m³/hr x 93.15
(LP) or m³/hr x 37.26 (NG)
CONTROLS
2-Line Plain Text Multilingual LCD Display
Mode Buttons: Auto
Manual
Off
Ready to Run/Maintenance Messages
Engine Run Hours Indication
Programmable start delay between 2-1500 seconds
Utility Voltage Loss/Return to Utility Adjustable
Future Set Capable Exerciser/Exercise Set Error Warning
Run/Alarm/Maintenance Logs
Engine Start Sequence
Starter Lock-out
Smart Battery Charger
Charger Fault/Missing AC Warning
Low Battery/Battery Problem Protection and Battery Condition Indication
Automatic Voltage Regulation with Over and Under Voltage Protection
Under-Frequency/Overload/Stepper Overcurrent Protection
Safety Fused/Fuse Problem Protection
Automatic Low Oil Pressure/High Oil Temperature Shutdown
Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown
High Engine Temperature Shutdown
Internal Fault/Incorrect Wiring Protection
Common External Fault Capability
Field Upgradable Firmware
Simple user interface for ease of operation.
Automatic Start on Utility failure. 7 day exerciser.
Start with starter control, unit stays on. If utility fails, transfer to load takes place.
Stops unit. Power is removed. Control and charger still operate.
Standard
Standard
Standard (programmable by dealer only)
From 140-171 V/190-216 V
Standard
50 Events Each
Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration).
Starter cannot re-engage until 5 sec after engine has stopped.
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
**Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions - Standby: Applicable for supplying emergency
power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by
such factors as fuel Btu/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet (304.8 meters) above sea level; and also will decrease
about 1 percent for each 6 °C (10 °F) above 16 °C (60 °F).
3
17 kW
AIR-COOLED GENERATOR SETS
CSA Switch Features
• Electrically operated, mechanically-held contacts for fast, positive connections.
• Rated for all classes of load, 100% equipment rated, both inductive and resistive.
• 2 pole, 250 VAC contactors.
• 160 millisecond transfer time.
• Dual coil design.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA/UL 3R (indoor/outdoor rated) aluminum enclosure is standard.
No. of Poles
Current Rating (Amps)
Voltage Rating (VAC)
Utility Voltage Monitor (Fixed)*
-Pick-up
-Dropout
Return to Utility*
Exercise weekly for 12 minutes*
UL Listed
Enclosure Type
Withstand Rating (Amps)
Lug Range
2
200
120/240, 1Ø
80%
60%
approx. 13 sec.
Standard
Standard
NEMA/UL 3R
22,000
250 MCM - #6
*Function of Sync™ 2.0 Controller
W1
Dimensions
in
mm
200 Amps 120/240, 1ø
Open Transition Service Rated
Height
Width
Depth
H1
H2
W1
W2
26.0
30.0
12.5
16.0
7.1
660.4 762.0 317.5 406.4 180.3
DEPTH
4
www.honeywellgenerators.com
H1
H2
W2
AVAILABLE ACCESSORIES
Model #
Product
Description
005819-0
26R Wet Cell Battery
Every standby generator requires a battery to start the system. The recommended 26R wet
cell battery is for use with all air-cooled standby product.
006212-0
Cold Weather Kit
If the temperature regularly falls below 32 °F (0 °C), install a cold weather kit to maintain
optimal battery and oil temperatures. Kit consists of a battery warmer and oil filter heater
with built-in thermostats.
005621-0
Auxillary Transfer Switch
Contact Kit
The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large
electrical load you may not need.
006160-0
Paint Kit
If the generator enclosure is scratched or damaged, it is important to touch-up the paint to
protect from future corrosion. The paint kit includes the necessary paint to properly maintain
or touch-up a generator enclosure.
006484-0
Scheduled Maintenance Kit
Scheduled maintenance kits provide all the hardware necessary to perform complete routine
maintenance on a Honeywell automatic standby generator.
DIMENSIONS & UPC
637.6 mm
[25.1 in]
1218 mm
[47.9 in]
731.9 mm
[28.8 in]
642 mm
[25.3 in]
LEFT SIDE VIEW
Generac Power Systems, Inc.
S45 W29290 Hwy. 59
Waukesha, WI 53187
Tel: 1-855-GEN-INFO
honeywellgenerators.com
1226 mm
[48.3 in]
FRONT VIEW
0198060SBY-G
December 2013
© Generac Power Systems, Inc. All rights reserved.
Specifications subject to change without notice.
The Honeywell Trademark is used under
license from Honeywell International Inc.
Honeywell International Inc. makes no representation
or warranties with respect to this product.
This product is manufactured by Generac Power Systems, Inc.
Model
UPC
006282-0
696471062823