TOOLS AND MATERIALS REQUIRED:
Blade
Screwdriver
SAFETY PRECAUTIONS:
Wiring supplies
as required by
electrical code
1. TURN OFF ELECTRICAL POWER BEFORE STARTING INSTALLATION OF LIGHT FIXTURE.
2. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR
WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
3. IF POWER SUPPLY CORDS OR WIRES ARE LOCATED WITHIN 3" OF BALLAST, USE WIRE OR CORD SUITABLE FOR AT LEAST
90˚ (194˚F). TO PREVENT RISK OF FIRE, DO NOT USE FIXTURE ON DIMMING CIRCUITS.
4. THIS FIXTURE MUST BE GROUNDED PROPERLY. CONNECT THE GROUND WIRE (BARE COPPER OR GREEN) TO THE AC
SUPPLY GROUND WIRE (BARE COPPER OR GREEN) OR GROUND SCREW IN THE ELECTRICAL OUTLET BOX. IF GROUND
WIRE IS NOT AVAILABLE IN YOUR AC SUPPLY WIRE SYSTEM, PLEASE CONSULT A QUALIFIED ELECTRICIAN BEFORE
PROCEEDING THE ELECTRICAL CONNECTION.
5. USE ONLY ENERGY STAR APPROVED BALLAST (WITH LAMP SOCKETS) MANUFACTURED BY CSA FILE NUMBER 226237
AND MARKETED BY CANARM LIMITED. THIS BALLAST IS REPLACEABLE BY A QUALIFIED ELECTRICIAN WITHOUT
CUTTING OF THE WIRES.
INSTALLATION: NOTE: FIXTURE GROUND WIRE MUST BE CONNECTED FOR LAMP TO OPERATE.
T-slot
Metal fixture
spring
clip
1
2
1.
Lay lamp on it’ s back (metal
surface down). Remove the plastic
lens by gently turning it and lifting
it away from the fixture. Remove
bulb (s)
2.
mounting screws
3
metal fixture
6.
Red/Yellow wires for
Inner lamp (22W or 32W)
Assemble the spring clips to
fixture, by positioning the clips on
the wide end of the "T"-slots with
the two downward turned legs of
the clips extending through the
fixture. Pull the clips away from
the fixture centre until the clips
snap into the "T"-slots.
Blue/Yellow wires for
Outer lamp (32W or 40W)
7.
3.
Secure the fixture’s mounting
screws (only screwing on halfway)
to electrical outlet box.
Insert the plug
to the lamp
lens fastener
metal fixture
4.
Using the wirenuts, connect
the ground wire (green) from the
fixtures to the ground wire from
electrical outlet box. Using the
wirenuts, connect the black wire
1. Green (ground wire)
2. Black or Brown (line voltage) from the fixture to the black wire
3. White or Light Blue (neutral)
from electrical outlet box, and
repeat same process with white
wires.
5.
Attach the fixture to the
mounting screws, turn fixture
clockwise, and tighten screws.
mounting screws
Place lamp over spring clips
and gently push over the third clip.
Repeat this for the second (inner)
circline bulb (for 2-lamp models
only).
THIS WIRING DIAGRAM IS
FOR 2-LAMP MODELS.
Red/Yellow wires for Inner lamp
(22W or 32W).
Blue/Yellow wires for Outer lamp
(32W or 40W).
acrylic
plastic
To install the acrylic plastic
lens
lens, hold lens up to the fixture,
8.
push handles on lens clips until it
is flush against the housing.
Restore power at fuse box or
circuit breaker box.
9.
WHEN YOU REPLACE BALLAST, PLEASE PROCESS FROM
STEP 8 TO 5. AFTER THAT PLEASE REPEAT THE NORMAL
PROCESS FROM STEP 5 TO 8.
QUESTIONS OR CONCERNS CONTACT CANARM AT:
1-800-265-1833 (English) / 1-800-567-2513 (French)
Monday through Friday 8:00 AM to 5:00 PM E.S.T.
Imported By: CANARM LTD., 2157 Parkedale Ave., Brockville, Ontario, K6V 5V6, Tel: (613) 342-5424, Fax: (613) 342-8437