HPE BladeSystem c3000 Enclosure

QuickSpecs
HPE BladeSystem c3000 Enclosure
Overview
HPE BladeSystem c3000 Enclosure
1.
2.
3.
4.
5.
HPE BladeSystem c3000 Enclosure - Front View
Device Bays 1 thru 8
Enclosure DVD Drive
Standby Onboard Administrator
Insight Display
Active Onboard Administrator
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
HPE BladeSystem c3000 Enclosure - Rear View
Local KVM interface
Interconnect Bay 1
Active Cool 100 Fans and Fan Bays
Interconnect Bay 2
Enclosure Up-link and Service Port
Enclosure Down-link
iLO/Onboard Administrator Port
iLO/Onboard Administrator Port 2
Power Supplies
Interconnect Bay 4
Interconnect Bay 3
Page 1
QuickSpecs
HPE BladeSystem c3000 Enclosure
Overview
HPE BladeSystem A HPE BladeSystem solutions start with an either a c7000 or c3000 enclosure. For the c3000 enclosure, key
enclosure components include hot-plug power supplies, hot-plug HPE Active Cool 100 Fans, and an optional
c-Class c3000
redundant BladeSystem Onboard Administrator module. Once the enclosure and its key components have been
Enclosure
selected, the following components can be added: interconnect modules, HPE ProLiant and Integrity server
blades, expansion blades, and optional HPE Insight Control for BladeSystem management software.
NOTE: HPE BladeSystem c3000 and c7000 Enclosures support G1 through Gen9 ProLiant and Integrity
server blades, subject to support requirements of the Onboard Administrator. Certain HPE ProLiant server
blades and options may require a specific version of the Onboard Administrator firmware. This firmware
release may also require other subsystem firmware upgrades. For further information, please see the HPE
Service Pack for ProLiant (SPP) website and the HPE Support Center document “HPE ProLiant Server
Blades - Compatibility with HPE BladeSystem c7000 and c3000 Enclosures and Firmware”.
A BladeSystem c3000 Enclosure holds up to 8 server blades and up to 4 expansion blades (not exceeding 8
total blades) plus redundant network and storage interconnects. It includes a shared, multi-terabit high-speed
midplane for wire-once connectivity of server blades to network and shared storage. Power is delivered through
a pooled power backplane that ensures the full capacity of the power supplies is available to all blades.
Each c3000 enclosure is built with the following functions:
• Up to 8 half-height server blades, 4 full-height server blades, and/or 4 expansion blades per enclosure
(not exceeding 8 total blades).
NOTE: For information on mixing half-height server blades, full-height server blades, and expansion
blades, please see the section titled "Server Blade, Expansion Blade, and Fan Population Guidelines"
later in this document.
• Up to 2 redundant I/O interconnect fabrics (Ethernet, Fibre Channel, iSCSI, SAS, etc.) supported
simultaneously within the enclosure.
• A single-phase power subsystem for flexibility in connecting to datacenter power, UPSs, or low-line
(100VAC to 110VAC) wall outlets.
CAUTION: when connecting directly to wall outlets, customers should determine the maximum
amperage of the wall outlet circuit to prevent power overload.
• Choice of AC power supplies.
• PARSEC enclosure design - Parallel, redundant and scalable cooling and airflow design.
• Up to six (6) hot-plug HPE Active Cool 100 Fans.
• Redundant hot-plug cooling, redundant hot-plug power supplies, redundant connections, redundant
interconnect modules, and optional redundant BladeSystem Onboard Administrator management
module.
An Onboard Administrator management module is built in to the enclosure with the following functions:
• Robust, multiple enclosure setup and control.
• Reports asset and inventory information for the devices in the enclosure.
• Reports thermal and power information, including real-time actual power usage per server and per
enclosure.
• Front-mounted Insight Display for easy management at the deployment site.
• Integrated access to all server blade iLOs from a single cable.
• Provides integrated access to interconnect bay device management ports from the single Onboard
Administrator cable.
• Single sign-on capability for all devices in the enclosure.
• Role-based security locally and/or with LDAP directory services.
• Provides a wizard-based initial setup process for easy configuration.
• An optional DVD drive for local software deployment, and HPE SmartStart deployment
• An optional local KVM interface for connection to KVM switches.
A BladeSystem c3000 enclosure provides the following benefits:
• With local and remote hardware management integrated across the solution, one full enclosure can be
Page 2
QuickSpecs
HPE BladeSystem c3000 Enclosure
Overview
•
•
•
•
•
•
managed as easily as one server.
Management and network interconnects extend scalability beyond a single enclosure, allowing
resources to be pooled and shared across multiple enclosures.
Accommodates multiple server and network designs in one enclosure.
Lower costs per server in comparison to rack-mounted servers
Lower power consumption in comparison to rack-mounted servers.
Reduced and simplified cabling in comparison to rack-mounted servers.
Investment protection supporting G1 through Gen9 server blades.
HPE ProLiant &
Integrity Server
Blades
Delivering best-in-class performance, choice and reliability on AMD Opteron™, Intel® Xeon® and Intel® Itanium®
processors for Windows, Linux, Solaris, OpenVMS, or HP-UX based servers; the HPE portfolio of server blades
supports a variety of application requirements for scale-out architectures. Hewlett Packard Enterprise offers
one-, two-, four- and eight -processor server blades, with the widest range of performance, and form factors. For
information please visit: https://www.hpe.com/us/en/integrated-systems/bladesystem.html .
HPE D2200sb
Storage Blade
Direct attached storage
The D2220sb Storage Blade delivers direct attached storage for c-Class Gen8 and greater server blades, with
support for up to twelve hot plug small form factor (SFF) SAS or SATA Midline hard disk drives or SAS/SATA
SSDs. The enclosure backplane provides a PCI Express connection to an adjacent c-Class server blade and
enables high performance storage access without any additional cables. The D2220sb Storage Blade features
an onboard Smart Array P420i controller with 2GB flash-backed write cache, for increased performance and
data protection. Up to four D2220sb storage devices can be supported in a single BladeSystem c3000
Enclosure for up to 57.6 TB of capacity.
Two ways to create shared storage with the D2220sb
Use HPE StoreVirtual VSA software to turn the D2220sb into an iSCSI SAN for use by all servers in the
enclosure and any server on the network. HPE VSA software is installed in a virtual machine on a VMware ESX
host server adjacent to the D2220sb. HPE StoreVirtual VSA turns the D2220sb into a scalable and robust iSCSI
SAN, featuring storage clustering for scalability, network RAID for storage failover, thin provisioning, snapshots,
remote replication, and cloning. Expand capacity within the same enclosure or to other BladeSystem enclosures
by adding additional D2220sb Storage Blades and HPE VSA licenses. A cost effective bundle of the D2220sb
Storage Blade and a HPE StoreVirtual VSA license makes purchasing convenient. If storage needs increase, add
HPE P4300 or P4500 systems externally and manage everything via a single pane of glass.
The HPE StoreEasy 3830 and 3840 Gateway Storage Blades are flexible storage server solutions for
BladeSystem environments. Combine the StoreEasy 3830 or 3840 with the D2220sb Storage Blade to enable
file serving and iSCSI shared storage inside the BladeSystem enclosure.
NOTE: The D2220sb requires a c3000 enclosure configuration with 6 fans
For more information, please visit:
https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04111399
HPE Ultrium Tape Tape blades are ideal for HPE BladeSystem c-Class customers who need a data protection solution but are not
connected into a storage area network (SAN). They provide direct attach data protection for the adjacent server
Blades
and network backup protection for all other data within the enclosure. The HPE tape blades are the industry's
first bladed tape drives and are developed exclusively for the BladeSystem c-Class enclosures.
For more information, please visit:
https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04154444
HPE BladeSystem Hewlett Packard Enterprise offers one of the broadest selections of interconnect fabric options in the industry
to provide network, SAN/network attached storage (NAS), and cluster connectivity. HPE BladeSystem
c-Class
interconnects provide:
Interconnect
Page 3
QuickSpecs
HPE BladeSystem c3000 Enclosure
Overview
Options
•
•
•
•
HPE Virtual Connect devices, designed to reduce networking costs and simplify network configuration
and provisioning.
Seamless integration of Ethernet, FC, iSCSI, and SAS fabrics: Standard-based switch options include
Cisco, Brocade, and Hewlett Packard Enterprise products that integrate within your existing standards.
Built-in redundancy: rear-mounting interconnect modules designed for redundant interconnections
between server blades and switches.
Cable reduction: Interconnect switches provide up to 32-to-1 network cable reductions per server
blade enclosure
HPE BladeSystem c-Class Interconnect and Mezzanine Components:
https://www.hpe.com/h20195/v2/getpdf.aspx/c04284204.pdf?ver=10
Factory Express
Portfolio for
Servers and
Storage
HPE Factory Express offers configuration, customization, integration and deployment services for Hewlett
Packard Enterprise servers and storage products. Customers can choose how their factory solutions are built,
tested, integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking, installation, complex configuration
and design services as well as individual factory services, such as image loading, asset tagging and custom
packaging. Hewlett Packard Enterprise products supported through Factory Express include: a wide array of
servers and storage: HPE Integrity, HPE ProLiant & HPE ProLiant & Integrity Server Blades, HPE BladeSystem,
HPE 9000 servers as well as the MSAxxxx, VA7xxx, EVA, XP, rackable tape libraries and configurable network
switches.
For more information on Factory Express services for your specific server model please contact your sales
representative or go to: http://www.hpe.com/info/factoryexpress
HPE Simple
Configurator
One Config Simple (OCS) is a guided self-service tool to help sales and non-technical people provide customers
with initial configurations in 3 to 5 minutes. You may then send the configuration on for configuration help, or
use in your existing ordering processes. If you require "custom" rack configuration or configuration for products
not available in OCS, please contact the HPE Customer Business Center or an Authorized Partner for assistance.
https://h22174.www2.hpe.com/SimplifiedConfig/Welcome
HPE Insight
Management
software
Insight Management
Managing the growing number of servers can be complex and expensive for your
organization. IT managers need to address changing business needs with tools that
meet the challenges of managing today's complex Datacenters.
HPE Insight Management lowers the cost of running your HPE ProLiant servers by
providing you with best-in-class management tools, including HPE Insight Control, HPE
Virtual Connect Enterprise Manager (VCEM), and HPE Matrix Operating Environment.
Insight Management increases your productivity and reduces your operating costs to
get you higher value from your HPE ProLiant servers.
Electronic download of Insight Management Media
Insight Management software media is available for free download (not including
license entitlement certificates) at this website:
http://www.hpe.com/info/servermanagement
Software media available for download includes:
• HPE Insight Control
• HPE Insight Control for Microsoft® System Center
• HPE Insight Control for VMware vCenter Server
• HPE Virtual Connect Enterprise Manager (VCEM)
• HPE Matrix Operating Environment
Page 4
QuickSpecs
HPE BladeSystem c3000 Enclosure
Overview
Customers will receive an Insight Control or Matrix Operating Environment license
entitlement certificate via physical shipment or email. The license
entitlement certificate must be redeemed online or via fax in order to
obtain the license activation key(s).
One year of 24x7 Software Technical Support and Updates are included with your
purchased licenses.
Hewlett Packard Enterprise provides a complete range of installation and support
services to ensure the successful deployment and operations of your server
infrastructure. For more information about support services and licensing
options, see the following website: http://www.hpe.com/info/servermanagement
Insight Software Media Kit (DVDs)
Physical media (DVDs) are also available for purchase from Hewlett Packard Enterprise
or from your authorized reseller (PN 436222-B21)
Service Pack for
ProLiant (SPP)
Customers should use the HPE Service Pack for ProLiant to update firmware, drivers,
and related utilities: https://www.hpe.com/servers/spp/
HPE Integrated Lights- HPE Integrated Lights-Out (iLO) simplifies server setup, health monitoring, power and
Out (iLO)
thermal control, and lights-out remote administration of ProLiant ML, DL, and BL
servers. HPE iLO functions without additional software and can be accessed from any
location via a web browser. HPE iLO works hand-in-hand with HPE Systems Insight
Manager, Insight Control and Insight Dynamics for ProLiant, helping customers unleash
the value of the ProLiant platform and deliver the highest possible quality of IT service.
For more information, visit: http://www.hpe.com/info/ilo
HPE Insight Control
HPE Insight Control, a product option, delivers essential infrastructure management
that can help save time and money by making it easy to deploy, migrate, monitor,
remote control, and optimize your IT infrastructure through a single, simple
management console. For more information, see
http://www.hpe.com/info/servermanagement
HPE Insight Control includes one year of 24 x 7 HPE Software Technical Support and
Update Service ensuring rapid access to Hewlett Packard Enterprise support staff and
proactive delivery of software updates. For more information about this service, please
visit: http://www.hpe.com/info/servermanagement
HPE Matrix Operating The HPE Matrix Operating Environment (Matrix OE) for ProLiant and Integrity servers
Environment
is an integrated command center that helps you instantly adjust to dynamic business
demands. This advanced infrastructure management software lets you reduce the cost
of common data center tasks by up to 40 percent while keeping pace with your
changing business.
The HPE Matrix OE includes the automated provisioning, optimization, and recovery
management capabilities for HPE CloudSystem Matrix, the ideal platform for private
cloud and Infrastructure as a Service (IaaS).
For more information, see http://www.hpe.com/info/matrixoe.
HPE Power
Advisor
The HPE Power Advisor is a tool provided by Hewlett Packard Enterprise to assist in the estimation of power
consumption and proper selection of components including power supplies at a system, rack, and multi-rack
level. A variety of additional features are also provided including a condensed bill of materials, a cost of owner
Page 5
QuickSpecs
HPE BladeSystem c3000 Enclosure
Overview
ship calculator, and a power report. The HPE Power Advisor allows for the mixing of rack, blade, and other
products in a single environment.
Hewlett Packard Enterprise highly recommends using the HPE Power Advisor tool to ensure the number of
power supply options you have selected can fully support your BladeSystem configuration and to review
maximum system power ratings for facilities planning purposes.
HPE Power Advisor is available at: http://www.hpe.com/info/hppoweradvisor
Warranty
Warranty - This product is covered by a global limited warranty and supported by HPE Services and a
worldwide network of Hewlett Packard Enterprise Authorized Channel Partners. Hardware diagnostic support
and repair is available for three years from date of purchase. Support for software and initial setup is available
for 90 days from date of purchase. Additional support may be covered under the warranty or available for an
additional fee. Enhancements to warranty services are available through HPE Pointnext operational services or
customized service agreements.
• Enclosure: Three-year parts and labor, on-site limited global warranty. Certain restrictions and
exclusions apply
• Enclosure options: Fans, Power Supplies, BladeSystem Onboard Administrator, 1 Year parts only or
enclosure warranty
• HPE BladeSystem Interconnects: 1 Year parts and labor, on-site regardless of the warranty period for
the system in which they are installed
• HPE Storage Fibre Channel switches have a maximum warranty period of one (1) year regardless of
the warranty period for the system in which they are installed
Hard drives have either a one year or three year warranty; refer to specific hard drive QuickSpecs for details.
Page 6
QuickSpecs
HPE BladeSystem c3000 Enclosure
Service and Support
Service and
Support
HPE Technology Services for Industry Standard Servers and BladeSystem
Capitalizing on HPE ProLiant server and HPE BladeSystem capabilities requires a service partner who
understands your increasingly complex business technology environment. That's why it makes sense to team
up with the people who know Hewlett Packard Enterprise infrastructure hardware and software best - the
experienced professionals at HPE Services.
Protect your business beyond warranty with HPE Pointnext operational services
HPE Pointnext operational services offer complete care and support expertise with committed response choices
designed to meet your IT and business needs.
HPE Foundation Care services offer scalable reactive support-packages for Hewlett Packard Enterprise servers
and software. You can choose the type and level of service that is most suitable for your IT and business needs.
HPE Proactive Care delivers high levels of system availability through proactive service management and
advanced technical response. HPE Datacenter Care provides highly flexible environmental support to address
unique customer business needs.
Choose recommended services for your c3000 BladeSystem enclosure or contact your Hewlett Packard
Enterprise sales representative or authorized HPE ServiceOne partner for additional HPE Pointnext operational
services information
Recommended HPE Pointnext operational services for your HPE product
Optimized Care
3-Year HPE 6 hour Call to Repair Response, Proactive Care
Combined reactive and proactive support for hardware and software helping optimize your systems and
delivering high levels of availability through proactive service management and advanced technical response.
Hardware problem resolution to return the hardware in operating condition within 6 hours of the initial service
request. A Technical Account Manager, as your single point of contact, will own your call or issue end to end
until resolved.
https://www.hpe.com/h20195/v2/getpdf.aspx/4aa3-8855eee.pdf
HPE Installation and Startup Service for HPE BladeSystem c-Class Infrastructure for c3000 enclosure
Provides for hardware installation (c-Class ProLiant and Integrity server blades, storage blades, Ethernet
Interconnects and Virtual Connect) and software installation and startup of a BladeSystem c3000 Infrastructure
in a single enclosure including deployment of OS on all blades or deployment of OS (two blades) and HPE
Insight Control, plus Server Deployment (formerly RDP).
https://www.hpe.com/h20195/v2/getpdf.aspx/4aa0-5964enw.pdf
HPE Installation and Startup Service for HPE BladeSystem c-Class Enhanced Network
Provides for the configuration and testing of BladeSystem Ethernet interconnect switches and Virtual Connect
to facilitate proper implementation of network protocols and access to advanced features.
https://www.hpe.com/h20195/v2/getpdf.aspx/4aa0-5969enw.pdf
Standard Care
3-Year HPE 24x7 4 hour response, Proactive Care Service
This service gives you combined reactive and proactive support including rapid access to our Advanced
Solution Center to manage and prevent problems and a Technical Support Specialist with a broad level of
technical knowledge that will engage with additional technical expertise as needed from the Hewlett Packard
Enterprise vast global resources.
https://www.hpe.com/h20195/v2/getpdf.aspx/4aa3-8855eee.pdf
HPE Installation and Startup Service for HPE BladeSystem c-Class Infrastructure for c3000 enclosure
Provides for hardware installation (c-Class ProLiant and Integrity server blades, storage blades, Ethernet
Interconnects and Virtual Connect) and software installation and startup of a BladeSystem c3000 Infrastructure
in a single enclosure including deployment of OS on all blades or deployment of OS on two blades and HPE
Page 7
QuickSpecs
HPE BladeSystem c3000 Enclosure
Service and Support
Insight Control, plus Server Deployment (formerly RDP).
https://www.hpe.com/h20195/v2/getpdf.aspx/4aa0-5964enw.pdf
HPE Installation and Startup Service for HPE BladeSystem c-Class Enhanced Network
Hewlett Packard Enterprise provides for the configuration and testing of BladeSystem Ethernet interconnect
switches to facilitate proper implementation of network protocols and access to advanced features.
https://www.hpe.com/h20195/v2/getpdf.aspx/4aa0-5964enw.pdf
Related Services
HPE Proactive Care Personalized Support - Environmental Option
The Personalized Support option provides an assigned Account Support Manager who can bring best practices
from across the industry plus extra technical skills to your IT team. This option is only available as an add-on to
HPE Proactive Care Support.
HPE Proactive Select Service
Provides a flexible way to purchase HPE best-in-class consultancy and technical services. You can buy
Proactive Select Service Credits when you purchase your hardware and then use the credits over the next 12
months. https://www.hpe.com/h20195/V2/GetPDF.aspx/4AA2-3842ENW.pdf
Additional HPE Packaged Support Services (formerly Care Pack) can be found at:
https://www.hpe.com/us/en/services/it-support.html
Insight Online /
Insight Remote
Support
HPE Insight Remote Support provides 24 X 7 remote monitoring, proactive notifications, and problem
resolution. This comes at no additional cost with your HPE solution. Learn more about Insight Remote Support
(https://www.hpe.com/info/insightremotesupport/docs)and Insight Online
(https://www.hpe.com/h20195/v2/getpdf.aspx/c04123234.pdf)
NOTE: Insight Remote Support is a prerequisite for Proactive Care. All blades within a single HPE
BladeSystem enclosure must be at the same service level.
HPE Support
Center
Personalized online support portal with access to information, tools and experts to support Hewlett Packard
Enterprise business products. Submit support cases online, chat with HPE experts, access support resources or
collaborate with peers. Learn more https://www.hpe.com/us/en/support.html
The HPE Support Center Mobile App allows you to resolve issues yourself or quickly connect to an agent for
live support. Now, you can get access to personalized IT support anywhere, anytime.
HPE Insight Remote Support and HPE Support Center are available at no additional cost with a Hewlett
Packard Enterprise warranty, HPE Care Pack or Hewlett Packard Enterprise contractual support agreement.
NOTE: HPE Support Center Mobile App is subject to local availability.
Parts and
Materials
Hewlett Packard Enterprise will provide HPE-supported replacement parts and materials necessary to maintain
the covered hardware product in operating condition, including parts and materials for available and
recommended engineering improvements.
Parts and components that have reached their maximum supported lifetime and/or the maximum usage
limitations as set forth in the manufacturer's operating manual, product quick-specs, or the technical product
data sheet will not be provided, repaired, or replaced as part of these services.
For more
information
The defective media retention service feature option applies only to Disk or eligible SSD/Flash Drives replaced
by Hewlett Packard Enterprise due to malfunction.
To learn more on HPE ProLiant servers and HPE BladeSystem servers, please contact your Hewlett Packard
Enterprise sales representative or Hewlett Packard Enterprise Authorized ServiceOne partner. Or visit:
https://www.hpe.com/us/en/integrated-systems/bladesystem.html
Page 8
QuickSpecs
HPE BladeSystem c3000 Enclosure
Pre-Configured Models
HPE BladeSystem NOTE: Hewlett Packard Enterprise does not allow factory integration of options into pre-configured
c-Class Server Blade models. Any additional options purchased will be shipped separately.
NOTE: If you desire a custom configuration, please see the "Configuration Information - Factory Integrated
Enclosures
Models" section of this QuickSpecs.
HPE BLc3000 Platinum Enclosure with 4 AC Power Supplies 6 Fans ROHS 8 Insight
696908-B21
Control Licenses
NOTE: Includes 4 1200W AC Common Slot Platinum Plus Hot Plug Power Supplies, 6
Active Cool 100 Fans, DVD drive, Rail Kit, Onboard Administrator DDR2 module, 4 6ft
C13 to C14 PDU power cords, 7 bay blanks, and 8 Insight Control Licenses.
HPE BLc3000 Platinum Enclosure with 4 AC Power Supplies 6 Fans ROHS Trial Insight
696909-B21
Control License
NOTE: Includes 4 1200W AC Common Slot Platinum Plus Hot Plug Power Supplies, 6
Active Cool 100 Fans, DVD drive, Rail Kit, Onboard Administrator DDR2 module, 4 6ft
C13 to C14 PDU power cords, 7 bay blanks, and 8 Insight Control Trial Licenses.
Page 9
QuickSpecs
HPE BladeSystem c3000 Enclosure
Configuration Information Factory Integrated Models
NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations
are ordered, Hewlett Packard Enterprise recommends contacting your local sales representative for information on Factory
Integrated Model product offerings and requirements.
For a configuration of the HPE BladeSystem, please do the following:
Step 1: Select desired model, configuration, and quantity of HPE ProLiant server and expansion
blades per enclosure (required)
NOTE: Each HPE BladeSystem c-Class Server Blade Enclosure holds up to 8 half-height server blades, 4 full-height server blades,
and/or 4 expansion blades per enclosure (not exceeding 8 total blades).
NOTE: HPE BladeSystem c3000 and c7000 Enclosures support G1 through Gen9 ProLiant and Integrity server blades, subject to
support requirements of the Onboard Administrator. Certain HPE ProLiant server blades and options may require a specific
version of the Onboard Administrator firmware. This firmware release may also require other subsystem firmware upgrades. For
further information, please see the HPE Service Pack for ProLiant (SPP) website and the HPE Support Center document “HPE
ProLiant Server Blades - Compatibility with HPE BladeSystem c7000 and c3000 Enclosures and Firmware”.
NOTE: For server and expansion blade (storage, tape, and PCI Expansion) information, please visit:
https://www.hpe.com/us/en/integrated-systems/bladesystem.html
Step 2: Determine the HPE BladeSystem c3000 Enclosure(s) and choose required options
(One of the following from each list unless otherwise noted)
Select the base server blade enclosure configuration
HPE BladeSystem
c3000 c-Class
Server Blade
Enclosures
NOTE: The enclosures listed below include 6 HPE Active Cool 100 Fans, a DVD drive, rack rails, and a single
DDR2 Onboard Administrator module.
NOTE: The power supply kits, power cables, interconnects, etc. are added per the steps below.
NOTE: The enclosures listed below include the required blanking panels (device bay, interconnect module,
fan, power, and redundant OA module blanking panels) as required per the ordered configuration. If the
configuration is modified at a later date, additional blanking panels (ordered separately) may be required.
NOTE: All c-Class enclosures support HPE ProLiant, Integrity and blades in either mixed or homogenous
configurations, subject to support requirements of the Onboard Administrator. The AH257C enclosure is
suggested for configurations primarily used with Integrity blades.
HPE BLc3000 Platinum Configure-to-order Enclosure with 6 Fans ROHS Trial Insight
Control License
HPE Integrity BLc3000 CTO Enclosure
696910-B21
AH257C
Select the type and quantity of power supply kits
HPE c3000
Enclosure Power
Supplies
NOTE: Each enclosure must include only one type of power supply. Mixing of power
supplies is not supported, except during hot swaps to different level or higher efficient
power supplies. The Onboard Administrator will exhibit a mismatch error due to mixed
power supplies until all power supplies are matched.
NOTE: The HPE AC Common Slot Platinum Plus Power Supply PN 656364-B21 meets the
80 PLUS Platinum power 94% efficiency requirement. The 80 PLUS program is a unique
forum that unites electric utilities, the computer industry, and consumers in an effort to
bring energy efficient technology solutions to the marketplace. 80 PLUS independently
tests power supply efficiency and publically posts the results on 80Plus.org.
NOTE: HPE highly recommends using the HPE Power Advisor tool to ensure the number
of power supply options you have selected can fully support your BladeSystem
configuration and to review maximum system power ratings for facilities planning
Page 10
QuickSpecs
HPE BladeSystem c3000 Enclosure
Configuration Information Factory Integrated Models
purposes. HPE Power Advisor is available at: http://www.hpe.com/info/hppoweradvisor .
NOTE: For a full enclosure, you can either order 4 or more power supplies to support an
N+1 redundant configuration or 6 power supplies to support an N+N redundant
configuration.
HPE 1200W Common Slot Platinum Plus Hot Plug Power Supply Kit
NOTE: Platinum power supplies are required to enable power discovery services.
NOTE: Includes a 6ft C13 to C14 PDU power cord.
656364-B21
Step 3: Select optional enclosure options
HPE Redundant
Onboard
Administrator
HPE BLc3000 Dual DDR2 Onboard Administrator
NOTE: Certain HPE ProLiant server blades and options require the latest version of the
Onboard Administrator firmware. This firmware release may also require other subsystem
firmware upgrades. For information on the latest firmware versions, please see the Blades
Firmware Maintenance website at: https://www.hpe.com/us/en/product.../pip.hpeonboard-administrator.3188465.html
488100-B21
HPE c3000 KVM
Modules and
Adapters
HPE BLc3000 KVM Option
NOTE: For use with in-rack KVM switches.
437575-B21
HPE Optional
Power Cords
HPE C20 - C13 WW 250V 15Amp 2.0m Jumper Cord
NOTE: For use with PDUs accepting C20 power cords.
NOTE: Order 1 for each power supply.
HPE C13-NEMA 6-15P 10A/250V 3.6m Black Power Cord
AF590A
A0N33A
Step 4: Select one to four interconnects
The following is a list of various HPE BladeSystem c-Class interconnect modules (Virtual Connect, Ethernet, Fibre Channel, and
SAS interconnects). A pair of interconnects must be ordered if redundancy is required. For detailed interconnect options consult
the specific interconnect QuickSpecs: https://www.hpe.com/h20195/v2/getpdf.aspx/c04284204.pdf?ver=10
NOTE: Options to specific c-Class interconnects are not included in the list below. Consult the individual interconnect QuickSpecs
to obtain part numbers for interconnect options such as cables, SFPs, etc.
NOTE: Interconnect Bay 1 must contain one of the Network Interconnects.
NOTE: The HPE BladeSystem c-Class interconnects ship as single units unless otherwise noted. Interconnects must be ordered in
quantities of two for redundancy support.
HPE BladeSystem HPE Virtual Connect Flex-10/10D Module for c-Class BladeSystem
c-Class Network HPE 6125G/XG Ethernet Blade Switch
Interconnects
HPE 6125G Ethernet Blade Switch
HPE 1GB Ethernet Pass-Thru Module for c-Class BladeSystem
HPE 10GbE Ethernet Pass-Thru Module for c-Class BladeSystem
HPE 10GbE Ethernet Pass-Thru TAA-compliant Module II for c-Class BladeSystem
HP Cisco B22HP Fabric Extender for BladeSystem c-Class
HP Cisco B22HP Fabric Extender with 16 FET for BladeSystem c-Class
NOTE: Includes 16 Cisco Fabric Extender Transceivers. These transceivers can be used to
connect the Fabric Extender with a parent Nexus 5000 over optical cable up to 100
meters using OM3 grade fiber.
HPE SAS Switch
HPE 6Gb SAS Switch Single Pack for HPE BladeSystem c-Class
638526-B21
658250-B21
658247-B21
406740-B21
538113-B21
854194-B22
641146-B21
657787-B21
BK763A
Page 11
QuickSpecs
HPE BladeSystem c3000 Enclosure
Configuration Information Factory Integrated Models
HPE 6Gb SAS Switch Dual Pack for HPE BladeSystem c-Class
NOTE: Please see the QuickSpecs for Technical Specifications and additional information
at: https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04123176
(Worldwide)
HPE BladeSystem HPE Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem
c-Class FC SAN
HPE Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem
Interconnects
HPE 4GB Fibre Channel Pass-thru Module for c-Class BladeSystem
Brocade 8/12c SAN Switch for BladeSystem c-Class
Brocade 8/24c SAN Switch for BladeSystem c-Class
Brocade 8/24c Power Pack+ SAN Switch for BladeSystem c-Class
HPE MDS 8/12c Fabric Switch 12-port Upgrade LTU
NOTE: Licensed per switch.
HP StoreFabric Data Center Network Manager BladeSystem LTU
NOTE: Installed on DCNM Server, each license can be assigned to only one switch.
BK764A
466482-B21
572018-B21
403626-B21
AJ820C
AJ821C
AJ822C
TA804A
TC367A
Step 5: Select rack power distribution for installing the enclosure into a rack.
NOTE: A pair of HPE Power Distribution Units (PDU) must be ordered for AC feed redundancy. If AC redundancy is not required,
a single PDU or UPS may be acceptable.
NOTE: Select HPE PDUs and UPSs are listed later in this document. For additional HPE PDUs and UPSs, please see
http://www.hpe.com/info/rackandpower
Step 6: Select wall outlet power cords (For connection to standard wall outlets)
NOTE: Select one wall outlet power cord for each power supply when plugging the power supplies into a wall outlet.
NOTE: Wall Outlet power cords should only be used with low-line (100VAC to 110VAC) power sources. If high-line power outlets
are required, safety regulations require the use of a PDU or a UPS between the c3000 enclosures power supplies and wall outlets.
NOTE: A standard 6ft PDU power cord (C13 to C14) is included with each AC power supply, so these wall outlet power cords are
not required if you plan to plug the power supplies into a PDU or UPS.
NOTE: Order the appropriate power cord for your countries standard electrical outlets.
NOTE: For additional power cable information, please visit:
http://www.hpe.com/info/rackandpower
HPE Power Cords HPE C13 - Nema 5-15P US/CA 110V 10Amp 1.83m Power Cord
NOTE: HPE Power cord (6 ft) 1.83 meter 10A C-13-UL domestic power cord, for
grounded USA 110V wall outlets.
HPE C13 - JIS C8303 JP 100V 12Amp 2.0m Power Cord
NOTE: HPE Power cord 2 meter C13 Japan low-line power cord, for Japanese 100V wall
outlets.
HPE C20 - C13 WW 250V 15Amp 2.0m Jumper Cord
NOTE: For use with PDUs accepting C20 power cords.
AF556A
AF572A
AF590A
Page 12
QuickSpecs
HPE BladeSystem c3000 Enclosure
Related Options
HPE c-Class BladeSystem Miscellaneous Blanks Option Kit
HPE c3000
Enclosure Options NOTE: Contains 1 each of c3000/c7000 Active Cool Fan blank, c3000/c7000
interconnect module blank, c7000 Onboard Administrator blank, c3000 local KVM blank,
c3000 power supply blank, c7000 power supply blank, c3000 DVD blank, and a c3000
mini-divider.
NOTE: This kit should only be ordered to replace lost or damaged blanks.
HPE c-Class BladeSystem Bay Blank with Coupler Option
NOTE: This is option contains one half-height device blank and a coupler that can be used
for the c3000 and c7000 enclosures.
NOTE: Order quantity of one 412150-B21 for filling a half-height bay; the coupler is not
used.
NOTE: Order quantity of two 412150-B21 for filling a full-height bay. One coupler is
installed between the two half-height blanks to be connected together to create a fullheight blank.
NOTE: This kit should only be ordered to replace lost or damaged blanks.
412148-B21
HPE c3000 Rack
Brackets
HPE BLc3000 10000 Series Rack Shipping Bracket Option
NOTE: Required when shipping a c3000 enclosure in a HPE 10000 series rack. Please
order 1 kit per enclosure.
461384-B21
HPE Onboard
Administrator
HPE BLc3000 Dual DDR2 Onboard Administrator
NOTE: Second Onboard Administrator Module for the DDR2 OA module.
NOTE: Support for second Order Administrator Module for c3000 Enclosure.
NOTE: This module fits into an HPE c3000 DDR2 Onboard Administrator.
488100-B21
412150-B21
HPE c-Class Power NOTE: Each enclosure must include only one type of power supply. Mixing of power
Supply
supplies is not supported, except during hot swaps to different level or higher efficient
power supplies. The Onboard Administrator will exhibit a mismatch error due to mixed
power supplies until all power supplies are matched.
NOTE: The HPE AC Common Slot Platinum Plus Power Supply PN 656364-B21 meets the
80 PLUS Platinum power 94% efficiency requirement. The 80 PLUS program is a unique
forum that unites electric utilities, the computer industry, and consumers in an effort to
bring energy efficient technology solutions to the marketplace. 80 PLUS independently
tests power supply efficiency and publically posts the results on 80Plus.org.
NOTE: HPE highly recommends using the HPE Power Advisor tool to ensure the number
of power supply options you have selected can fully support your BladeSystem
configuration and to review maximum system power ratings for facilities planning
purposes. HPE Power Advisor is available at: http://www.hpe.com/info/hppoweradvisor.
NOTE: For a full enclosure, you can either order 4 or more power supplies to support an
N+1 redundant configuration or 6 power supplies to support an N+N redundant
configuration.
HPE c3000 KVM
Module and
Adapters
HPE 1200W Common Slot Platinum Plus Hot Plug Power Supply Kit
NOTE: Platinum power supplies are required to enable power discovery services
NOTE: Includes a 6ft C13 to C14 PDU power cord.
656364-B21
HPE BLc3000 KVM Option
NOTE: For use with in-rack KVM switches
437575-B21
Page 13
QuickSpecs
HPE BladeSystem c3000 Enclosure
Related Options
HPE BladeSystem NOTE: For detailed interconnect options, consult the specific interconnect QuickSpecs:
c-Class Network https://www.hpe.com/h20195/v2/getpdf.aspx/c04284204.pdf?ver=10
Interconnects
NOTE: Options to specific c-Class interconnects are NOT included in the list below.
Consult the individual interconnect QuickSpecs to obtain part numbers for interconnect
options such as cables, SFPs, etc.
NOTE: Interconnect Bay 1 must contain one of the Ethernet capable interconnect
modules.
NOTE: The HPE BladeSystem c-Class interconnects ship as single units unless otherwise
noted. Interconnects must be ordered in quantities of two for redundancy support.
HPE 6125G Ethernet Blade Switch
HPE 6125G/XG Ethernet Blade Switch
HPE 1GB Ethernet Pass-Thru Module for c-Class BladeSystem
NOTE: The Ethernet Pass-Thru Module is shipped as a single unit and should be ordered
in quantities of two.
658247-B21
658250-B21
406740-B21
HPE BladeSystem NOTE: For detailed interconnect options, consult the specific interconnect QuickSpecs:
c-Class FC SAN
https://www.hpe.com/h20195/v2/getpdf.aspx/c04284204.pdf?ver=10
Interconnects
NOTE: Options to specific c-Class interconnects are NOT included in the list below.
Consult the individual interconnect QuickSpecs to obtain part numbers for interconnect
options such as cables, SFPs, etc.
NOTE: Interconnect Bay 1 must contain one of the Ethernet capable interconnect
modules.
NOTE: The HPE BladeSystem c-Class interconnects ship as single units unless otherwise
noted. Interconnects must be ordered in quantities of two for redundancy support.
HPE Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem
HPE Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem
HPE 4GB Fibre Channel Pass-thru Module for c-Class BladeSystem
Brocade 8/12c SAN Switch for BladeSystem c-Class
Brocade 8/24c SAN Switch for BladeSystem c-Class
Brocade 8/24c Power Pack+ SAN Switch for BladeSystem c-Class
Brocade 8/16Gb Embedded FC Switch 12-port Upgrade LTU
Cisco MDS 9124e Switch for BladeSystem c-Class 12-port Upgrade LTU
HPE Insight
Software
HPE Insight Control
HPE Insight Management Media Kit
NOTE: HPE Insight Management Media Kit contains DVDs without licenses. Contains HPE
Systems Insight Manager, HPE Insight Control, HPE Matrix Operating Environment, and
Virtual Connect Enterprise Manager software. Uses an integrated installer to perform
quick and accurate software installation and updates.
NOTE: Licenses ship without media. The Insight Control Media Kit can be ordered
separately, or can be downloaded. See https://www.hpe.com/us/en/productcatalog/detail/pip.3312156.html
NOTE: The "for bundling with an enclosure" license kits can only be ordered together with
a BladeSystem c3000 or c7000 enclosure on the same order.
NOTE: Customer will receive a license entitlement certificate, which must be redeemed
online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7
HPE Software Technical Support Service.
NOTE: For additional License Kits, please see the QuickSpecs at:
https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04123391
466482-B21
572018-B21
403626-B21
AJ820C
AJ821C
AJ822C
T5517A
T5169A
C6N31A
Page 14
QuickSpecs
HPE BladeSystem c3000 Enclosure
Related Options
(Worldwide)
HPE iLO Advanced HPE iLO Advanced for BladeSystem including 1yr 24x7 Support 8-server LTU
for BladeSystem
License
512489-B21
HPE Virtual Connect Enterprise Manager including 1yr 24x7 Support Single c3000
HPE Virtual
Connect Enterprise Enclosure LTU
Manager
NOTE: This license allows 1 BL-c3000 enclosure to be managed with VCEM. Customer will
receive a printed license entitlement certificate via physical shipment. The license
entitlement certificate must be redeemed online or via fax to obtain the license activation
key(s). Includes one year of 24 x 7 HPE Software Technical Support and Update Service.
NOTE: For additional License Kits, please visit:
https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04154443
(Worldwide)
459867-B21
HPE c-Class
Storage Blades
HPE Expansion
Blade
HPE D2220sb Build-to-order Storage Blade
NOTE: Includes 3yr NBD Parts-Only Warranty Service
HPE D2220sb Configure-to-order Storage Blade
NOTE: Includes 3yr NBD Parts-Only Warranty Service
NOTE: The D2220sb requires a c7000 Enclosure configuration with 10 fans.
NOTE: Please see the HPE D2220sb Storage Blade QuickSpecs for technical specifications
and additional information at:
https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04111399.
HPE 10GbE Ethernet Pass-Thru Module II for c-Class BladeSystem
HPE BLc PCI Expansion Blade
NOTE: Please see the QuickSpecs for Technical Specifications and additional information
at: https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04123380
(Worldwide)
QW917A
QW918A
854194-B21
448018-B21
HPE Power
NOTE: A pair of HPE Power Distribution Units must be ordered for AC feed redundancy.
Distribution Units NOTE: Additional HPE Power Distribution Units are available than those listed below. For
a complete list of all HPE PDUs and additional information please visit:
http://www.hpe.com/info/rackandpower
Modular PDUs
NOTE: Please see the following QuickSpecs for additional options including shorter jumper
cables and country specific power cords:
https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04123438 (Worldwide)
HPE Two C13 PDU Extension Bar
NOTE: Please see the UPS and PDU cable matrix's on the HPE Power Protection and
Management page. Under Power Cords, click on the "HPE Power Cord Matrix" link. That
link will list cable descriptions, requirements, and specifications for UPS and PDU units.
Please see the following link: http://www.hpe.com/info/rackandpower
AF500A
HPE Intelligent
NOTE: A pair of PDUs must be ordered for AC feed redundancy.
Power Distribution NOTE: Additional HPE Power Distribution Units are available than those listed below. For
Page 15
QuickSpecs
HPE BladeSystem c3000 Enclosure
Related Options
Units (iPDU)
a complete list of all HPE PDUs and additional information please visit:
https://www.hpe.com/us/en/integrated-systems/rack-power-cooling.html
iPDU Core Units
HPE Intelligent Modular 4.9kVA/L6-30P 24A/208V Outlets (6) C19/Horizontal NA/JP PDU
HPE Intelligent Modular 3Ph 8.6kVA/L15-30P 24A/208V Outlets (6) C19/Horizontal NA/JP
PDU
HPE Intelligent Modular 7.3kVA/60309 3-wire 32A/230V Outlets (6) C19/Horizontal INTL
PDU
HPE Intelligent Modular 3Ph 11kVA/60309 5-wire 16A/230V Outlets (6) C19/Horizontal
INTL PDU
iPDU Extension Bars
HPE 5xC13 Intelligent PDU Extension Bar G2 Kit
HPE 5xC13 Outlets Power and UID LEDs Pair Standard Extension Bar
NOTE: Please see the QuickSpecs for Technical Specifications and additional information:
https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04123329 (Worldwide)
HPE
Uninterruptible
Power Systems/
AF520A
AF522A
AF525A
AF526A
AF547A
AF528A
NOTE: Additional HPE Uninterruptable Power Systems (UPSs) are available than those
listed below. For a complete list of all HPE UPSs and additional information, please visit:
http://www.hpe.com/info/rackandpower
R5000 Uninterruptible Power System (UPS)
HPE R5000 3U IEC309-32A High Voltage INTL Uninterruptible Power System
HPE R5000 3U L630 High Voltage NA/JP Uninterruptible Power System
NOTE: Please see the QuickSpecs for Technical Specifications and additional information
at: https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04154372
(Worldwide)
R7000 Uninterruptible Power System (UPS)
HPE R7000 4U 50A High Voltage NA/JP Uninterruptible Power System
HPE R7000 4U IEC-32A High Voltage INTL Uninterruptible Power System
HPE R5KVA and R7KVA 3U Extended Runtime Module
NOTE: Please see the QuickSpecs for Technical Specifications and additional information
at: https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04123199
(Worldwide)
AF461A
AF460A
AF462A
AF463A
AF464A
HPE Basic Power NOTE: A pair of PDUs must be ordered for AC feed redundancy.
Distribution Units NOTE: Additional HPE Power Distribution Units are available than those listed below. For
a complete list of all HPE PDUs and additional information please visit:
http://www.hpe.com/info/rackandpower
HPE 1.9kVA 120 Volt 12 Outlet NA/JP Basic Power Distribution Unit
HPE Basic 1.9kVA/L5-20P 16A/120V Outlets (12) 5-20R/Horizontal NA/JP PDU
HPE Basic 2.8kVA/L5-30P 24A/120V Outlets (18) 5-20R/Vertical NA/JP PDU
HPE Basic 3.6kVA/60320 C20 Detachable 16A/230V Outlets (12) C13/Horizontal WW
PDU
HPE Basic 4.9kVA/60320 C20 Detachable 16A/230V Outlets (20) C13/Vertical WW PDU
HPE Basic 4.9kVA/L6-30P 24A/208V Outlets (20) C13/Vertical NA/JP PDU
HPE Basic 4.9kVA/L6-30P 24A/208V Outlets (24) C13 (6) C19/Vertical NA/JP PDU
HPE Basic 8.3kVA/CS8265C 40A/208V Outlets (30) C13 (6) C19/Vertical NA PDU
H5M54A
H5M55A
H5M56A
H5M57A
H5M58A
H5M59A
H5M60A
Page 16
QuickSpecs
HPE BladeSystem c3000 Enclosure
Related Options
HPE Basic 3Ph 8.6kVA/L15-30P 24A/208V Outlets (18) C13/Vertical NA/JP PDU
HPE Basic 3Ph 8.6kVA/L15-30P 24A/208V Outlets (24) C13 (6) C19/Vertical NA/JP PDU
HPE Basic 3Ph 5.7kVA/ L21-20P 16A/120-208V Outlets (24) C13 (3) 5-20R/Vertical
NA/JP PDU
HPE Basic 3Ph 8.6kVA/L21-30P 24A/120-208V Outlets (24) C13 (3) C19 (3) 520R/Vertical NA/JP PDU
HPE Basic 3Ph 11kVA/60309 16A/240V Outlets (36) C13 (6) C19/Vertical NA PDU
HPE Basic 7.3kVA/60309 5-wire 32A/230V Outlets (20) C13/Vertical INTL PDU
HPE Basic 7.3kVA/60309 3-wire 32A/230V Outlets (24) C13 (6) C19/Vertical INTL PDU
HPE Basic 11kVA/60309 63A 3-wire 48A/230V Outlets (30) C13 (6) C19/Vertical INTL
PDU
HPE Basic 3Ph 11kVA/60309 5-wire 16A/230V Outlets (24) C13 (6) C19/Vertical INTL
PDU
HPE Basic 3Ph 11kVA/60309 5-wire 16A/230V Outlets (36) C13 (6) C19/Vertical INTL
PDU
HPE Basic 9.2kVA/50A Terminal Block 40A/230V Outlets (30) C13 (6) C19/Vertical WW
PDU
HPE 277 Volt options for H3X08A
HPE 800VA - 277V Input / 230V Output NA Rack Mount Transformer
NOTE: Please see the QuickSpecs for Technical Specifications and additional information:
https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04111392 (Worldwide)
HPE Power Cords HPE C20 - C13 WW 250V 15Amp 2.0m Jumper Cord
NOTE: For use with PDUs that accept C20 power cords.
NOTE: For additional power cable information, please visit:
http://www.hpe.com/info/rackandpower
HPE Rack Series HPE Intelligent Series Rack
(Graphite Metallic) HPE 42U 600mm x 1075mm Enterprise Pallet Rack
HP 42U 600mm x 1075mm Enterprise Shock Rack
NOTE: Please see the QuickSpecs for Technical Specifications and additional information
at: https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04123237
(Worldwide)
NOTE: For additional information regarding rack cabinets, please see the following URL:
http://www.hpe.com/info/rackandpower
HPE Rack Options Keyboards and Monitors
HPE USB US Keyboard/Mouse Kit
HPE USB UK Keyboard/Mouse Kit
HPE USB FR Keyboard/Mouse Kit
HPE USB ES Keyboard/Mouse Kit
HPE USB DE Keyboard/Mouse Kit
HPE USB JP Keyboard/Mouse Kit
HPE USB IT Keyboard/Mouse Kit
HPE USB CN Keyboard/Mouse Kit
HPE USB AE Keyboard/Mouse Kit
HPE USB RU Keyboard/Mouse Kit
NOTE: Please see the QuickSpecs for Technical Specifications and additional information:
https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04168349 (Worldwide)
H5M61A
H5M62A
H5M63A
H5M64A
H5M67A
H5M68A
H5M70A
H5M71A
H5M72A
H5M73A
H5M75A
H3X09A
AF590A
BW903A
BW904A
631341-B21
631344-B21
631346-B21
631348-B21
631358-B21
631360-B21
631362-B21
631364-B21
638212-B21
638214-B21
Page 17
QuickSpecs
HPE BladeSystem c3000 Enclosure
Related Options
HPE Server Console Switch G2 with Virtual Media & CAC
HP 0x2x16 KVM Server Console Switch G2 with Virtual Media CAC Software
HP 0x2x32 KVM Server Console Switch G2 with Virtual Media CAC Software
NOTE: Please see the QuickSpecs for Technical Specifications and additional information:
https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04168373 (Worldwide)
HPE IP Console Switch G2 with Virtual Media & CAC
HP 1x1Ex8 KVM IP Console Switch G2 with Virtual Media CAC Software
HP 2x1Ex16 KVM IP Console Switch G2 with Virtual Media CAC Software
HP 4x1Ex32 KVM IP Console Switch G2 with Virtual Media CAC Software
KVM USB Cnsl Itfc Adapter 1PK ALL
NOTE: Please see the QuickSpecs for Technical Specifications and additional information:
https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04168374
HPE KVM Switches
HP BladeSystem c-Class KVM Interface Adapter
HP 1x4 USB/PS2 KVM Console Switch
HP 1x4 KVM Console 6ft USB Cable
NOTE: required for supporting USB peripherals.
NOTE: Please see the QuickSpecs for Technical Specifications and additional information:
https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04164460 (Worldwide)
NOTE: For additional information regarding KVM switches, Serial Console servers, rack
mount monitors, keyboards and all related options please see the following URL:
https://www.hpe.com/h20195/v2/GetHTML.aspx?docname=c04164460
Rack Options
HPE Advanced Series Rack Tie Down Kit
AF618A
AF619A
AF620A
AF621A
AF622A
336047-B21
AF605A
AF611A
AF613A
AF076A
NOTE: For additional information regarding Rack Options, please see the following URL:
http://www.hpe.com/info/rackandpower
HPE Pointnext
operational
services
NOTE: Some options, such as Fibre Channel switches for the HPE c-Class BladeSystem,
are not covered under the c3000 enclosure Care Packs and carry separate Care Packs.
Care Pack service level support for these options should always be uplifted to match
existing storage or server service level.
Please view the option QuickSpecs or contact your Hewlett Packard Enterprise sales
representative or Hewlett Packard Enterprise Authorized ServiceOne partner for Care
Pack information.
Proactive Care Services
HPE 3 year Proactive Care 24x7 c3000 Enclosure Service
HPE 3 year Proactive Care Call to Repair c3000 Enclosure Service
HPE 3 year Proactive Care 24x7 c3000 Enclosure with Insight Control Service
HPE 3 year Proactive Care Call to Repair c3000 Enclosure with Insight Control Service
U3C42E
U3C45E
U3P19E
U3P22E
Installation & Start-up Services
HPE Installation c3000 Enclosure and Server Blade Service
HPE BladeSystem c3000 Infrastructure Startup Service
HPE BladeSystem c3000 + OS Startup Service
HPE BladSys c3000 Encd Network Startup Service
HPE Hardware Install c-Class Enclosure and Server Blade Service
UH749E
UF817E
UF818E
UF814E
UE494E
Page 18
QuickSpecs
HPE BladeSystem c3000 Enclosure
Related Options
NOTE: Additional HPE Pointnext operational services can be found at:
https://www.hpe.com/us/en/services/it-support.html
Page 19
QuickSpecs
HPE BladeSystem c3000 Enclosure
Power Specifications
HPE 1200W Common Slot Platinum Hot Plug Power Supply Kit
Part Number
656364-B21
Input Voltage Range ( V rms )
100-240
Frequency Range (Nominal) ( Hz )
50 / 60
100
120
Nominal Input Voltage ( Vrms )
Maximum Rated Output Wattage
800
900
Nominal Input Current ( A rms )
9.1
8.4
Maximum Rated Input Wattage Rating ( Watts )
897
999
Maximum Rated VA ( Volt-Amp )
909
1012
Efficiency ( % )
89.2
90.1
Power Factor
Leakage Current ( mA )
0.42
0.50
Maximum Inrush Current (A peak )
Maximum Inrush Current duration ( mS )
Maximum British Thermal Unit Rating ( BTU-Hr )
3061
3408
HPE 1200W Common Slot Silver Hot Plug Power Supply Kit
Part Number
500172-B21
Input Voltage Range ( V rms )
100-240
Frequency Range (Nominal) ( Hz )
50 / 60
100
120
Nominal Input Voltage ( Vrms )
Maximum Rated Output Wattage
800
900
Nominal Input Current ( A rms )
9.7
9.0
Maximum Rated Input Wattage Rating ( Watts )
930
1034
Maximum Rated VA ( Volt-Amp )
970
1079
Efficiency ( % )
86
87
Power Factor
Leakage Current ( mA )
0.42
0.50
Maximum Inrush Current (A peak )
Maximum Inrush Current duration ( mS )
Maximum British Thermal Unit Rating ( BTU-Hr )
3174
3530
200
1200
6.7
1321
1338
90.9
0.83
4506
200
1200
7.0
1348
1406
89
0.83
4600
208
1200
6.4
1319
1337
91.0
0.998
0.87
30
20
4501
208
1200
6.8
1348
1406
89
0.97
0.87
30
20
4600
220
1200
6.1
1317
1334
91.1
230
1200
5.8
1315
1332
91.2
240
1200
5.5
1314
1331
91.3
0.92
0.96
1.00
4493
4487
4483
220
1200
6.4
1348
1406
89
230
1200
6.1
1348
1406
89
240
1200
5.9
1348
1406
89
0.92
0.96
1.00
4600
4600
4600
Page 20
QuickSpecs
HPE BladeSystem c3000 Enclosure
Server Blade, Expansion Blade, and Fan Population Guidelines
Fan & power supply bay numbering
Rack power supply bay numbering
Fan bay numbering
Power supplies and fans must be placed in the following bays
Number of Fans
4
6
Fan Bays Used
2,4,5, 6
All bays filled
Number of Power Supplies
(for PS Redundant or non-redundant mode)
2
3
4
5
6
Power Supply Bays Used
1&2
1, 2, & 3
1, 2, 3, & 4
1 through 5
All bays
Number of Power Supplies (for AC Redundant mode)
Place Power Supplies in Bays:
2
1&4
4
1, 2, 4, & 5
6
All bays filled
NOTE: With four fans, the enclosure will support only 4 half-height server blades in the bottom half of the enclosure device bays.
With six fans, all 8 server bays may be filled.
NOTE: For correct operation, fans and server blades must be installed in the correct bays. The Onboard Administrator will ensure
that fans and blades are correctly placed before allowing the system to power on.
The c3000 enclosure is divided into 2 zones by the horizontal support metalwork. The lower zone (zone 1) includes bays 1, 2, 5, and
6. The upper zone (zone 2) contains bays 3, 4, 7, and 8. Within each zone a removable bay divider is used to support half-height
devices. To install a full-height blade in either zone this bay divider must be removed.
NOTE: Please read the RTF card (included with each c3000 enclosure) and the "HPE BladeSystem c3000 Setup and Installation
Guide" for more information on the use, installation, and removal of bay dividers.
Page 21
QuickSpecs
HPE BladeSystem c3000 Enclosure
Server Blade, Expansion Blade, and Fan Population Guidelines
Half-height server blade bay numbering
HPE BladeSystem c3000 Enclosure – Racks
1. Device Bay 1
2. Device Bay 2
3. Device Bay 3
4. Device Bay 4
5. Device Bay 5
6. Device Bay 6
7. Device Bay 7
8. Device Bay 8
NOTE: Half-height server blades should be populated from the bottom half of the enclosure, in the following order (bays 1, 5, 2,
6, 3, 7, 4, & 8)
Full-height server blade bay numbering
HPE BladeSystem c3000 Enclosure – Racks
1. Device Bay 1
2. Device Bay 2
3. Device Bay 3
4. Device Bay 4
NOTE: Full-height servers should be populated from the bottom to the top (bays 1 through 4). With four fans, only the bottom 2
bays can be used. With six fans, all bays can be used.
Page 22
QuickSpecs
HPE BladeSystem c3000 Enclosure
Server Blade, Expansion Blade, and Fan Population Guidelines
Full-height and half-height server blade mixed configurations
Each enclosure zone can support up to 1 full-height, double wide server blade, up to 2 full-height, single-wide server blades, or up to
4 half-height server blades. Additionally, zone 2 supports a mix of 1 full-height, single-wide server blade and up to 2 half-height
server blades. A mixture of blades sizes is not supported in zone 1.
An overview of the mixed server blade population rule best practices are summarized below. For detailed expansion blade rules and
guidelines, please see the documentation that ships with the enclosure and server blade.
1. One full-height, single-wide server and up two half-height servers may be mixed in zone 2 (the upper zone); mixing is not
allowed in zone 1 (the lower zone).
2. The full-height, single wide server must be installed in the lower bays 3 and 7 and half-height server(s) directly above in
bays 4 and 8.
3. Half-height server blades should be installed in the order of bays 4 then 8.
4. Before installing any full-height server blades, remove the bay divider that is used to support half-height devices.
5. A mini-divider is installed between bays 4 and 8. A mini-divider is shipped with each c3000 enclosure.
NOTE: Please read the RTF card (included with each c3000 enclosure) and the "HPE BladeSystem c3000 Setup and Installation
Guide" for more information on the use, installation, and removal of bay dividers and the mini-divider for mixed configurations.
NOTE: Expansion blades can be installed in zone 2 along with both full-height, single-wide and half-height blades. For more
information, please see the "Expansion blades" section later in this document.
Expansion blades
Expansion blades consist of storage blades, tape blades, and the PCI Expansion Blade. Up to 4 expansion blades are supported per
HPE BladeSystem c-Class c3000 Enclosure. Expansion blades may be installed in the same zone as half-height and full-height,
single-wide server blades. Expansion blades are not supported with full-height, double-wide server blades. An expansion blade is
installed directly above a server blade, also known as a partner server blade. An overview of the expansion blade population rule best
practices are summarized below. For detailed expansion blade rules and guidelines, please see the documentation that ships with the
enclosure and expansion blade.
Expansion blade population best practices for half-height server blades:
1. One half-height partner server blade supports one expansion blade.
2. Identify the partner server blade to be installed with the expansion blade. The two blades always occupy a pair of slots as
follows: 1 & 2, 3 & 4, 5 & 6, and 7 & 8.
3. Each c3000 zone contains a removable divider (also known as a device bay shelf) that is used to support half-height
devices. This divider is remains installed whether the half-height devices are server or expansion blades.
Expansion blade population best practices for full-height, single-wide server blades:
1. A full-height, single-wide server blade may be mixed with half-height expansion blades in zone 2 (the upper zone) of the
c3000 enclosure; mixing is not allowed in zone 1 (the lower zone).
2. The full-height, single-wide partner server blade must be installed in the lower bays 3 and 7 and half-height devices directly
above in bays 4 and 8.
3. The full-height, single-wide server partner blade supports one or two expansion blades in bays 4 and 8.
4. Before installing any full-height, single-wide server blades, remove the bay divider that is used to support half-height
devices.
5. A mini-divider is installed between bays 4 and 8. A mini-divider is shipped with each c3000 enclosure.
6. If installing only one expansion blade, install the expansion blade in bay 8. The remaining half-height bay (bay 4) may be
populated with either a half-height device bay blank of a half-height server blade; the half-height server blade may not be
partnered with the expansion blade.
7. If installing two expansion blades, the expansion blades may be two storage blades, two tape blades, two PCI Expansion
Blades, or a mixture of any two.
8. Expansion blades are not supported with full-height, double-wide server blades.
NOTE: Please read the RTF card (included with each c3000 enclosure) and the "HPE BladeSystem c3000 Setup and Installation
Guide" for more information on using bay dividers and the mini-divider for mixed configurations.
Page 23
QuickSpecs
HPE BladeSystem c3000 Enclosure
Server Blade, Expansion Blade, and Fan Population Guidelines
NOTE: For detailed expansion blade rules and guidelines, please see the documentation that ships with the enclosure and
expansion blade.
Page 24
QuickSpecs
HPE BladeSystem c3000 Enclosure
Technical Specifications
Enclosure Unit
Dimensions
(H x W x D)
(with bezel)
Weight
(approximate)
10.4 x 19.1 x 32.977 in (265 x 485 x 835 mm)
Maximum
300 lb (136 kg)
(one enclosure with 8 blades
and 4 interconnects installed)
Minimum
130 lb (59 kg)
(one enclosure without blades
and interconnects)
Input Requirements Rated Line Voltage
(per AC power supply)
Rated Input Current
Rated Input Frequency
BTU Rating
Maximum per power supply
90 – 132 VAC
180 – 264 VAC
9.3 A (at 100 VAC)
9.7 A (at 120VAC)
7.8 A (at 200 VAC)
7.2 A (at 208 VAC)
6.8 A (at 220 VAC)
6.2 A (at 240 VAC)
47 to 63 Hz
2728 BTU/hr (at 100 VAC)
3069 BTU/hr (at 120VAC)
4092 BTU/hr (at 200 to 240 VAC)
Power Specifications To review typical system power ratings use the Power Calculator online tool located at
URL: https://paonline56.itcs.hpe.com/?Page=Index
800 W (at 100 VAC)
Power Supply Output Rated Steady-State Power
900 W (at 120 VAC)
(per power supply)
1200 W (at 200 to 240 VAC)
Maximum Peak Power
880 W (at 100 VAC)
990 W (at 120 VAC)
1350 W (at 200 to 240 VAC)
System Inlet
Temperature
Operating
Non-operating
Relative Humidity
(non-condensing)
Operating
Non-operating
Altitude
Operating
10° to 35°C (50° to 95°F) at sea level with an altitude
derating of 1.0°C per every 305 m (1.8°F per every
1000 ft) above sea level to a maximum of 3050 m
(10,000 ft), no direct sustained sunlight. Maximum rate
of change is 10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options installed.
System performance may be reduced if operating with a
fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of change
is 20°C/hr (36°F/hr).
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-condensing.
5 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-condensing.
3050 m (10,000 ft). This value may be limited by the
type and number of options installed. Maximum
Page 25
QuickSpecs
HPE BladeSystem c3000 Enclosure
Technical Specifications
Non-operating
Option Kits
allowable altitude change rate is 457 m/min (1500
ft/min).
9144 m (30,000 ft). Maximum allowable altitude
change rate is 457 m/min (1500 ft/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared average
bystander position A-Weighted sound pressure levels (LpAm) when the product is
operating in a 23°C ambient environment. Noise emissions were measured in
accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296
(ECMA 109).
Idle
depends on server configuration & mix of server blades
Operating
varies by CPU utilization, server configuration, and mix
of server blades
Power Supply
Dimensions
Size
Weight
Fan Option Shipping Size
Dimensions
Weight
EnvironmentEnd-of-life
friendly Products Management and
and Approach
Recycling
Height: 1.515 in (38.48 mm)
Width: 3.4 in (86.36 mm)
Depth: 7.5 in (190.5 mm)
2.5 lbs (1.13 kg)
Height: 8.75 in (223 mm)
Width: 9.75 in (248 mm)
Depth: 15.88 in (403 mm)
4.0 lbs (1.8 kg)
Hewlett Packard Enterprise offers end-of-life Hewlett Packard Enterprise product
return, trade-in, and recycling programs in many geographic areas. For trade-in
information, please go to: http://www.hpe.com/info/recycle. To recycle your product,
please go to: http://www.hpe.com/info/recycle or contact your nearest Hewlett
Packard Enterprise sales office. Products returned to Hewlett Packard Enterprise will
be recycled, recovered or disposed of in a responsible manner.
The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment
information for each product type for use by treatment facilities. This information
(product disassembly instructions) is posted on the Hewlett Packard Enterprise web
site at: http://www.hpe.com/info/recycle. These instructions may be used by
recyclers and other WEEE treatment facilities as well as Hewlett Packard Enterprise
OEM customers who integrate and re-sell Hewlett Packard Enterprise equipment.
Page 26
QuickSpecs
HPE BladeSystem c3000 Enclosure
Summary of Changes
Date
23-Oct-2017
Version History
Version 69
Action
Changed
01-Aug-2014
From Version 58 to 59
Changed
Description of Change
Care Pack naming and Service and Support- Parts and Materials
updated.
SKU added in Configuration Information Factory Integrated Models
section:
854194-B22
Obsolete SKUs were deleted:
C6N32ABE, C6N33ABE.
URLs in document were updated.
Obsolete SKUs were deleted:
590863-B21, 431643-B21.
Configuration Information Factory Integrated Models and Related
Options sections were updated.
SKU added:
854194-B21
Obsolete SKUs were deleted:
516733-B21, AW563A, AW564A, 516733-B21, AW563A, AW564A,
BD883A, BS580B.
Overview, Configuration Information Factory Integrated Models,
Related Options, and Power Specifications sections were updated.
Removed discontinued -48VDC product and notes from QuickSpecs:
437573-B21.
SKUs updated in Configuration Information - Factory Integrated
Models and Related Options, from: AJ820B, AJ821B, AJ822B; to:
AJ820C, AJ821C, AJ822C.
Related Options section was updated
Obsolete SKUs were deleted:
451439-B21, 451438-B21, TC317A, AP880A, AF470A, AF471A,
AF466A, AF467A, AF468A, H3X07A, H3X08A, AZ870A, AZ871A,
AZ872A, AZ873A, AZ874A, AZ875A, AZ876A, AZ877A, AZ878A,
AZ879A, AZ880A, AZ881A, AZ882A, AZ883A, AZ884A, AZ885A,
AF616A, AF617A, AF626A, U6W98E, UF540E
Overview and Related Options sections were updated
Deleted SKU AF500A
Obsolete SKUs Deleted:
B7E01A, AF506A, AF914A
Overview, Pre-configured Models and Configuration Information
Factory Integrated Models sections were updated
What's new, Configuration Information Factory Integrated Models,
Related Options sections were updated
SKU Added:
696910-B21
Obsolete SKUs were removed:
AF603A, TC318A, AF508A, 498358-B21
Changes were made in North America QuickSpecs.
12-Jun-2017
From Version 67 to 68
Added
11-Jul-2014
From Version 57 to 58
Changed
Changes were made in North America QuickSpecs.
10-Jun-2014
From Version 56 to 57
Changed
Changes made throughout the QuickSpecs.
18-Feb-2014
From Version 55 to 56
Changed
Configuration Information and Related Options were revised.
10-Dec-2013
From Version 54 to 55
Changed
Changes were made throughout the QuickSpecs.
22-Nov-2013
From Version 53 to 54
Removed
Removed the What's New Section
Removed
03-Apr-2017
From Version 66 to 67
Changed
Removed
13-Feb-2017
From Version 65 to 66
Changed
Added
Removed
10-June 2016 From Version 64 to 65
Changed
Removed
25-Mar-2016
From Version 63 to 64
Changed
22-Jun-2015
From Version 62 to 63
Changed
Removed
20-Jan-2015
From Version 61 to 62
Changed
Removed
07-Nov-2014
From Version 60 to 61
Changed
09-Sep-2014
From Version 59 to 60
Changed
Added
Removed
Page 27
QuickSpecs
HPE BladeSystem c3000 Enclosure
Summary of Changes
Removed part number from the Related Options/ HPE c Class Power
Supply Section
13-Sep-2013
From Version 52 to 53
Changed
Configuration Information Factory Integrated Models and Related
Options were revised.
15-Mar-2013
From Version 51 to 52
Changed
Overview: Updated What's New section
Models: Updated HPE BladeSystem c-Class Server Blade Enclosures
HPE BladeSystem c-Class Overview: Updated HPE ProLiant &
Integrity Server Blades and HPE D2200sb Storage Blade.
Configuration Information Factory Integrated Models: Updated Step 2.
Related Options: Updated HPE Onboard Administrator, HPE c-class
Power Supply, HPE Insight Software and HPE Storage Blade.
Power Specifications: HPE 1200W Common Slot Platinum Hot Plug
Power Supply Kit and Note to section.
Removed
Removed "Platinum" reference throughout QS.
Removed NOTE from Technical Specifications section.
01-Mar-2013
From Version 50 to 51
Removed
Related Options: Removed TC276AAE and TC277AAE from HPE
Insight Software section.
19-Feb-2013
From Version 49 to 50
Changed
Changes made throughout the QS to reflect the title changes to HPE
BladeSystem c3000 Platinum Enclosure.
Models section was updated.
Service and Support section was completely revised.
Other changes made in the Configuration Information and Related
Options.
14-Dec-2012
From Version 48 to 49
Added
Configuration Information Factory Integrated Models: added models
Related Options: added parts in HPE Rack Series
24-Sep-2012
From Version 47 to 48
Changed
Changes made throughout the QuickSpecs.
31-Aug-2012
From Version 46 to 47
Changed
Changes made throughout the QuickSpecs.
14-May-2010
From Version 45 to 46
Changed
Changes made in the Related Options section.
26-Mar-2012
From Version 44 to 45
Changed
Changes made throughout the QuickSpecs.
06-Mar-2012
From Version 42 to 44
Added
Added a reference to Gen8.
14-Nov-2011
From Version 41 to 42
Changed
HPE Insight management software, Optimized, Standard and Basic
Care Packages and HPE c-Class Power Supply were revised.
29-Sep-2011
From Version 40 to 41
Changed
Revisions made in the Configuration Information and Related Options
sections.
26-Sep-2011
From Version 39 to 40
Changed
Power Supplies, HPE BladeSystem c-Class Interconnects, HPE Ultrium
Tape Blades and HPE Pointnext operational services were revised
What's New was added to the Overview
30-Aug-2011
From Version 38 to 39
Changed
Standard and Basic Care Packages were updated in Service and
Support
Changes were made throughout Configuration Information Factory
Integrated Models and Related Options
Page 28
QuickSpecs
HPE BladeSystem c3000 Enclosure
Summary of Changes
12-Aug-2011
From Version 37 to 38
Changed
Link corrections were made in the Related Options section.
24-Jun-2011
From Version 36 to 37
Changed
Changes made throughout the QuickSpecs. Including the removal of
ProCurve & StorageWorks.
03-Jun-2011
From Version 35 to 36
Changed
Changes made to North America and Canada only.
29-Apr-2011
From Version 34 to 35
Changed
The Service and Support section was completely revised and other
changes made throughout the QuickSpecs.
11-Feb-2011
From Version 33 to 34
Changed
Mixed Configuration - Full Height and Half Height Population was
revised
HPE R5500 UPS Tower Conversion Kit was removed from HPE
Uninterruptible Power Systems - Rack
HPE c3000 Enclosure Options was removed from Related Options
14-Jan-2011
From Version 32 to 33
Changed
HPE BladeSystem c-Class Interconnect and Mezzanine Components
URLs were modified in HPE BladeSystem c-Class Interconnects
Options
HPE Uninterruptible Power Systems product descriptions were
revised
These fans are for the HPE BladeSystem c3000 CTO Enclosure note
was removed from HPE c-Class Active Cool Fan in Step 2
HPE PCI Express Mezzanine pass-thru card for HPE BladeSystem
was removed from HPE c-Class Storage Blades
10-Jan-2011
From Version 31 to 32
Changed
HPE StorageWorks D2200sb Storage Blade was added and HPE
StorageWorks SB40c Storage Blade was removed
HPE Insight Control for BladeSystem Licenses, HPE Uninterruptible
Power Systems - Rack, HPE Insight Software and HPE Virtual
Connect Enterprise Manager product descriptions were revised
HPE Virtual Connect FlexFabric 10Gb/24-port Module for c-Class
BladeSystem is not compatible with the c3000 enclosure note was
added to HPE BladeSystem c-Class Ethernet Interconnects
15-Nov-2010
From Version 30 to 31
Changed
Product descriptions were revised throughout, Brocade SAN Switch
for HPE BladeSystem c-Class was added and HPE StorageWorks
Network Storage Servers was removed.
08-Oct-2010
From Version 29 to 30
Changed
HPE Tape Backup and HPE Pointnext operational services were
revised
Service and Support was added
HPE TFT7600 G2 KVM Console Rackmount Keyboard Monitors were
added to Keyboards and Monitors
Removed
HPE BladeSystem c3000 Enclosure Tower was removed
What's New was removed from the Overview
HPE c3000 Enclosure DVD Drive was removed
HPE 4Gb Virtual Connect Fibre Channel Module for c-Class
BladeSystem was removed from Step 3
HPE Insight Control, Single-Server License including 1 year of 24x7
Technical Support and Update was removed from HPE Insight
Software
Page 29
QuickSpecs
HPE BladeSystem c3000 Enclosure
Summary of Changes
HPE Disk Backup was removed from Related Options
02-Jul-2010
21-Jun-2010
From Version 28 to 29
From Version 27 to 28
Added
Mixing of the Active Cool 100 and Active Cool 200 in a c3000
enclosure is not supported note was added to HPE c-Class Active
Cool Fans.
Removed
Part numbers 508669-B21, AF600A and AF602A were removed and
2x16 Console Switch with Virtual Media was removed from HPE KVM
Switch Options.
Changed
HPE Rack 10000 G2 Series and HPE Rack Options were completely
revised
HPE Insight Control for Linux was added to HPE Insight Software
Removed
HPE 1Gb Virtual Connect Ethernet Module for c-Class BladeSystem,
HPE 10Gb Ethernet BL-c Switch and 10GbE Dual Port Mezzanine
Adapter for HPE BladeSystem c-Class were removed from HPE
BladeSystem c-Class Ethernet Interconnects
HPE Brocade 4/12 SAN Switch, HPE Brocade 4/24 SAN Switch
Power Pack and HPE Brocade 4/24 SAN Switch were removed from
HPE BladeSystem c-Class FC SAN Interconnects
4x1x16 IP Console Switch with Virtual Media and HPE USB KVM
Cable with audio, 6-2-pack were removed from HPE KVM Switch
Options
28-Apr-2010
From Version 26 to 27
Removed
Removed part number AH351B from a Note in Step 2A of the
Configuration Information section.
12-Mar-2010
From Version 25 to 26
Changed
NOTE was added to HPE 1200W -48V DC Common Slot Power
Supply and all references to 2 x 1 x 16 IP Console Switch with Virtual
Media, part number AF601A, were removed.
16-Feb-2010
From Version 24 to 25
Changed
Changes were made throughout the Configuration Information
Factory Integrated Models and Related Options sections.
25-Nov-2009
From Version 23 to 24
Changed
Minor edits were made within the QuickSpecs.
16-Nov-2009
From Version 22 to 23
Changed
Changes were made throughout the QuickSpecs.
02-Oct-2009
From Version 21 to 22
Changed
Changes made throughout the QuickSpecs except for the Models and
Technical Specifications sections.
25-Sep-2009
From Version 20 to 21
Changed
Changes made to the North America and Canada versions only.
28-Aug-2009
From Version 19 to 20
Changed
Changes made to the North America and Canada versions only.
17-Jul-2009
From Version 18 to 19
Changed
Revisions were made in the HPE BladeSystem c-Class Overview and
Related Options sections.
12-Jun-2009
From Version 17 to 18
Added
Rack Rails to NOTE for HPE BladeSystem c3000 CTO EnclosureRack in Step 2 of the Configuration Information - Factory Integrated
Models section
HPE StorageWorks D2D2504i Backup System to Data Protection in
the Related Options section
Changed
Updated the Keyboards and Monitors in the Related Options section
HPE BLc3000 Rack Rails was removed from Other Enclosure Options
in Step 2A of the Configuration Information - Factory Integrated
Models section
27-Apr-2009
From Version 16 to 17
Added
HPE ProLiant Onboard Administrator to the HPE BladeSystem cPage 30
QuickSpecs
HPE BladeSystem c3000 Enclosure
Summary of Changes
Class Overview section
Active Cool 100 Fan throughout the QuickSpecs
Changed
NOTE for HPE iLO Advanced Pack for BladeSystem or iLO Advanced
and purchase information NOTE for HPE Insight Control Suite (ICE)
in the HPE BladeSystem c-Class Overview section and a NOTE was
added to HPE Insight Control suite in the Related Options section
Replaced "ProLiant" with "Insight" for HPE Insight Essentials
Foundation Pack in Core Infrastructure Management in the HPE
BladeSystem c-Class Overview section
Revised Onboard Administrator for Tower Model and removed Power
Supplies from Step 2 of the Configuration Information Factory
Integrated Models section
Revised Additional c3000 Power Supplies and HPE Insight Control
suite for BladeSystem Licenses and added Redundant Onboard
Administrator to Step 2a of the Configuration Information Factory
Integrated Models section
Updates were made throughout the Models section and to the
NOTES section of the Configuration Information Factory Integrated
Models section
Completely revised HPE StorageWorks Ultrium Tape Blades, HPE
Insight Control suite (ICE) and Server Management Stand Alone
Software Products in the HPE BladeSystem c-Class Overview and
Related Options sections and Data Protection in the Related Options
section
Revisions were made throughout Step 2 and Step 2A in the
Configuration Information Factory Integrated Models section and to
Service and Support Offerings in the Related Options section
Removed 10642 G2 (42U) Rack Cabinet from HPE Rack 10000 G2
Series, 10642 Rear Extension Kit from Rack Options for Rack 10000
G2 Series and HPE Modular Cooling from the Related Options section
26-Jan-2009
From Version 15 to 16
Changed
Changes made throughout the entire QuickSpecs.
17-Nov-2008
From Version 14 to 15
Changed
30-Oct-2008
From Version 13 to 14
Removed
Changes were made to the following sections:
Overview
What's New
At A Glance
HPE BladeSystem c-Class Overview
HPE BladeSystem Overview
HPE SB40c Storage Blade
HPE StorageWorks Tape Blades
HPE BladeSystem c-Class Interconnect Enclosure
HPE Insight Control Environment for BladeSystem Management Suite
Server Management Stand Alone Software
HPE Enterprise Configurator
Configuration Information Factory Integrated Models
Step 2A: Select additional optional enclosure options
Step 3: Select additional (one to four) interconnects
Related Options
Other c3000 enclosure options
HPE BladeSystem c-Class Ethernet Interconnects
HPE BladeSystem c-Class FC SAN Interconnects
Removed model number 409513-B22 from the Related Options
Page 31
QuickSpecs
HPE BladeSystem c3000 Enclosure
Summary of Changes
15-Sep-2008
From Version 12 to 13
Changed
14-Jul-2008
From Version 11 to 12
Added
section.
Changes were made to the following sections:
Overview
What's New
At A Glance
HPE BladeSystem c-Class Overview
HPE BladeSystem Overview
HPE BladeSystem c-Class c3000 Enclosure
HPE Insight Control Environment for BladeSystem Management Suite
Configuration Information Factory Integrated Models
Step 2: Determine quantity of HPE BladeSystem c-3000 Enclosures
to purchase and choose Required Options
Step 2A: Select additional optional enclosure options
Step 3: Select additional (one to four) interconnects
Step 4: Select rack power distribution for installing the enclosure into
a rack.
Related Options
c3000 Enclosure Options
HPE BladeSystem c-Class c3000 Enclosure
Other c3000 enclosure options
HPE BladeSystem c-Class FC SAN Interconnects
HPE Monitored Power Distribution Unit
Additions made to the Overview, HPE BladeSystem c-Class Overview,
Configuration Information and Related Options sections:
HPE 8/12 and 8/24 SAN Switch c-Class BladeSystem
Power Cord, C20 C13, 15A, Universal Jumper, 2m
HPE D2D Backup Systems
Changed
Change was made to MSA1000 in Factory Express Portfolio in the
HPE BladeSystem c-Class Overview section and to Data Protection in
the Related Options section
HPE Insight Control Environment for BladeSystem Management Suite
Server Management Stand Alone Software Product
NOTES section for HPE NC512m Dual Port 10GbE Multifunction BLc Adapter in HPE BladeSystem c-Class Ethernet Connects
Headings for HPE Modular Power Distribution Unit and
Uninterruptible Power System in Step 4 of the Configuration
Information Factory Integrated Models section
Monitors and Keyboards and HPE KVM Switch Options in the Related
Options section
11-Apr-2008
From Version 10 to 11
Changed
Changes made to the North America and Canada QuickSpecs only.
31-Mar-2008
From Version 9 to 10
Added
Cisco Catalyst Blade Switch 3120X, Part #451439-B21 and Cisco
Catalyst Blade Switch 3120G, Part #451438-B21, were added to the
Configuration Information and Related Options sections and BL460c
Smart Buy Server Blade, Part #461273-001, was added to the Smart
Buys section.
Changed
Changes were made in the Overview, HPE BladeSystem c-Class
Overview, Configuration Information and Related Options sections.
14-Mar-2008
From Version 8 to 9
Changed
Changes made to the North America and Canada QuickSpecs only.
03-Mar-2008
From Version 7 to 8
Changed
Changes made to the North America and Canada QuickSpecs only.
Page 32
QuickSpecs
HPE BladeSystem c3000 Enclosure
Summary of Changes
11-Feb-2008
From Version 6 to 7
Changed
Changes were made throughout the QuickSpecs.
18-Jan-2007
From Version 5 to 6
Changed
Changes made to the North America and Canada QuickSpecs only.
14-Jan-2008
From Version 4 to 5
Added
The HPE BladeSystem c3000 Enclosure - Tower Model option was
added.
Changed
Changes were made throughout the QuickSpecs to reflect the
addition of the tower option.
02-Nov-2007
From Version 3 to 4
Changed
Changes made to the At A Glance section.
05-Oct-2007
From Version 2 to 3
Changed
Changes made to the Service and Support Offerings section of
Related Options.
01-Oct-2007
From Version 1 to 2
Changed
Changes made to the North America and Canada QuickSpecs only.
Sign up for updates
© Copyright 2017 Hewlett Packard Enterprise Development LP. The information contained herein is
subject to change without notice. The only warranties for Hewlett Packard Enterprise products and
services are set forth in the express warranty statements accompanying such products and services.
Nothing herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise
shall not be liable for technical or editorial errors or omissions contained herein.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel, the Intel logo,
Xeon and Xeon Inside are trademarks of Intel Corporation in the U.S. and other countries. AMD is a US
registered trademark of AMD Corporation.
c04123379 - 12790 - Worldwide - V69 - 23-October-2017
Page 33