TITLE/SITE T1.0 TITLE SHEET LEGAL JURISDICTION: STATE OF LOUISIANA STATE FIRE MARSHAL & CITY OF MINDEN BUILDING DEPARTMENT BUILDING CODE: IBC 2012, 2013 LSPC, IMC 2012, NEC 2011, 2009 NFPA 1010, 2012 IFGC, 2013 LSSC, 2010 ADA-ABA DEMOLITION N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F ACCESSIBILITY GUIDELINESTENANT AREA: D1.0 2,419 S.F. (INCLUDING 144 S.F. WALK-IN COOLER/FREEZER) SEATING: TYPE CONSTRUCTION: EXISTING SHELL II-B, SPRINKLERED EXISTING BUILDING IS TYPE M-MERCANTILE, ENTIRE BUILDING SQUARE FOOTAGE: APPROX. 28,000 SQ. FT. TABLE 503: TYPE III-B ALLOWABLE HEIGHT/AREA: 4 STORIES, 19,000 SQ. FT. TABLE 508.3.3 REQUIRED SEPARATION OF OCCUPANCIES: PROPOSED: EXISTING 1 HOUR SEPARATION PROVIDED, SPRINKLERS PROVIDED. SECTION 903.2.6 GROUP M: AN AUTOMATIC SPRINKLER SYSTEM SHALL BE PROVIDED THROUGH BUILDING CONTAINING A GROUP M OCCUPANCY WHERE ONE OF THE FOLLOWING CONDITIONS EXISTS: 1. WHERE A GROUP B FIRE AREA EXCEEDS 12,000 SQUARE FEET. 2. WHERE A GROUP B FIRE AREA IS LOCATED MORE THAN THREE STORIES ABOVE GRADE PLANE; OR 3. WHERE THE COMBINED AREA OF ALL GROUP M FIRE AREAS ON ALL FLOORS, INCLUDING ANY MEZZANINES, EXCEEDS 24,0000 SQUARE FEET. AN AUTOMATIC SPRINKLER SYSTEM IS REQUIRED PER CODE AND IS EXISTING. SPRINKLER HEADS WITHIN PIZZA HUT TENANT SPACE SHALL BE MODIFIED TO ADHERE TO THE NEW BUILDING LAYOUT. TABLE 1004.1.1 MAXIMUM FLOOR AREA ALLOWANCE PER OCCUPANT KITCHEN: 200 GROSS. FLOOR AREA = 1,178 SQ. FT. OCCUPANT LOAD: 1,178/ 200 = 6 OCCUPANTS FLOOR AREA = 918 SQ. FT. OCCUPANT LOAD: 918/ 15 = 62 OCCUPANTS TOTAL OCCUPANT LOAD: 68 OCCUPANTS UTILITIES: 25 PAIR CABLE IN 2" CONDUIT ELECTRIC SERVICE: ROOF FRAMING PLAN SLAB AND FRAMING DETAILS ARCHITECTURAL A1.0 FLOOR PLAN A1.1 DOOR AND WDW ELEVATION SCHEDULES A2.0 EQUIPMENT PLAN A2.1 EQUIPMENT SCHEDULE A3.0 ROOF PLAN A4.0 EXTERIOR ELEVATIONS A5.0 WALL SECTIONS A7.0 EXTERIOR CONSTRUCTION DETAILS A8.0 FLOOR FINISH PLAN A8.1 FINISH SCHEDULE A9.0 REFLECTED CEILING PLAN A10.0 INTERIOR ELEVATIONS - DINING A10.1 INTERIOR ELEVATIONS - SERVICE A10.2 INTERIOR ELEVATIONS - RESTROOMS A10.3 METRO SHELVING ASSEMBLY AIDES A11.0 INTERIOR CONSTRUCTION DETAILS A11.1 MILLWORK DETAILS A11.2 MILLWORK DETAILS A11.3 INTERIOR DETAILS ADA1.0 ACCESSIBILITY REQUIREMENTS ADA1.1 ACCESSIBILITY REQUIREMENTS M1.0 HVAC NOTES AND SCHEDULES M2.0 M3.0 DUCT AND DIFFUSER PLAN HOOD DWGS. M3.1 M3.2 M4.0 M5.0 M5.1 HOOD DWGS. HOOD DWGS. MECHANICAL DETAILS HVAC SPECIFICATIONS HVAC SPECIFICATIONS PLUMBING 400 AMPS / 3 PHASE / 120-208 VOLT 1,329.9 MBH WATER PRESSURE: S1.0 S2.0 MECHANICAL SEATING: 15 SF PER OCCUPANT # PHONE LINES: 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 STRUCTURAL 55 SECTION 302: OCCUPANCY CLASSIFICATION: PREVIOUS: M-MERCANTILE, PROPOSED: A-2 RESTAURANT GAS: DEMOLITION PLAN 45 - 60 PSI @ BLDG. POINT OF ENTRY P1.0 PLUMBING SCHEDULE P2.0 P3.0 P4.0 P5.0 P6.0 P7.0 WASTE & VENT PLAN WATER & GAS PLAN UNDERGROUND PLMB. ROUGH-IN RISER DIAGRAMS PLUMBING DETAILS PEPSI PLATFORM ELECTRICAL PROJECT SUMMARY A. ALL WORK SHALL CONFORM TO THE 2012 EDITION OF THE INTERNATIONAL BUILDING CODE, AND ALL OTHER APPLICABLE CODES, STANDARDS, AND REGULATIONS OF THE CITY OF MINDEN, LA AND PARISH OF WEBSTER. NAME ROOM NAME 1 B. IT IS INTENDED THAT A COMPLETE OCCUPIABLE BUILDING PROJECT IS PROVIDED. C. THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION (A.I.A. LATEST EDITION) ARE A PART OF THESE CONTRACT DOCUMENTS. A COPY IS ON FILE AT THE ARCHITECT'S OFFICE. D. DO NOT SCALE THESE DRAWINGS. VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. ANY DISCREPANCIES IN THESE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO STARTING WORK. G. G.C. SHALL PROVIDE EACH SUBCONTRACTOR WITH A COMPLETE AGENCY-PERMITTED DRAWING SET AT TIME OF CONSTRUCTION. H. IT IS THE G.C.'S RESPONSIBILITY TO CONFIRM THE AVAILABLE "RESIDUAL" WATER PRESSURE, PRIOR TO THE START OF ANY WORK, AND NOTIFY THE OWNER IF THE AVAILABLE PRESSURE IS NOT ADEQUATE TO SERVICE THE ANSUL SYSTEM OR OTHER PRESSURE SENSITIVE EQUIPMENT. I. G.C. SHALL CONFIRM MINIMUM RESIDUAL PRESSURE AVAILABLE AT HOOD ANSUL SYSTEM IS 33 PSI. J. ALL ABBREVIATIONS INCLUDED FOLLOW INDUSTRY STANDARDS. CONTACT ARCHITECT IF ANY ABBREVIATIONS ARE NOT CLEAR. ELEV. LETTER ELEV. SHEET SHEET NUMBER 4 AX.X X WINDOW NUMBER / DECOR ITEM NUMBER 3 8'-4" X EXTERIOR WALL FINISH NUMBER X KEY NOTE CEILING HEIGHT BLDG. SECTION LETTER X AX.X BLDG. SECTION SHEET X-000 EQUIPMENT NUMBER XX ROOM FINISH NUMBER X INTERIOR ELEVATION DESIGNATION DETAIL NUMBER X AX.X DIRECTION OF DETAIL DETAIL SHEET X 0'-0" ELEV OWNER CIVIL ENGINEER Pizza Hut 7100 Corporate Drive Plano, TX 75024 GPD GROUP 520 S. MAIN STREET, SUITE 2531 AKRON, OH 44311 CONTACT: ANTHONY BARCHANOWICZ PHONE: 216.518.5544 DOOR NUMBER 2 ELEVATION NUMBER E. ALL PROPOSED SUBSTITUTIONS SHALL BE APPROVED BY THE OWNER, IN WRITING, PRIOR TO INSTALLATION. F. G.C. IS RESPONSIBLE FOR SUBMITTAL, PAYING FEES AND OBTAINING ALL PERMITS ASSOCIATED WITH THE PROJECT EXCEPT GENERAL BUILDING PERMIT. THIS INCLUDES, BUT IS NOT LIMITED TO ELECTRICAL, MECHANICAL, PLUMBING, FIRE SPRINKLER, HOOD ANSUL, OR OTHER RELATED FIRE PERMITS, ENCROACHMENT PERMIT, ETC. OWNER WILL PAY FOR "CONNECTION FEES" ASSOCIATED WITH UTILITY PERMITS. G.C. REQUIRED TO PAY FOR TEMPORARY FACILITIES FEES AS REQUIRED TO COMPLETE THE WORK IN A TIMELY MANNER. X AX.X REVISION NUMBER BLDG. HEIGHT REFERENCE POINT X XXX 000 CONSTRUCTION MANAGER MECH. / ELEC. ENGINEER Pizza Hut 7100 Corporate Drive Plano, TX 75024 Contact: John McCarthy Phone: (407) 864-8260 GPD GROUP 520 S. MAIN STREET, SUITE 2531 AKRON, OH 44311 CONTACT: ANTHONY BARCHANOWICZ PHONE: 216.518.5544 ARCHITECT STRUCTURAL ENGINEER GPD GROUP 520 S. MAIN STREET, SUITE 2531 AKRON, OH 44311 CONTACT: ANTHONY BARCHANOWICZ PHONE: 216.518.5544 GPD GROUP 520 S. MAIN STREET, SUITE 2531 AKRON, OH 44311 CONTACT: ANTHONY BARCHANOWICZ PHONE: 216.518.5544 E2.0 E3.0 E4.0 E4.1 E5.0 E6.0 POWER /ROOF PLAN LIGHTING PLAN & SCHEDULE TELECOM PLAN POWER ROUGH-IN PLAN PANEL SCHEDULE AND RISER DIAGRAM ELECTRICAL DETAILS SHEET INDEX CONTRACT DATE: SHEAR WALL TYPE (STRUCTURAL) EQUIPMENT / FIXTURE NUMBER (M.E.P.) L. ALL CONTRACTORS SHALL VISIT THE SITE TO BECOME FAMILIAR WITH CONDITIONS AFFECTING THE SCOPE OF WORK. NO CONTRACT ADJUSTMENTS WILL BE PERMITTED DUE TO THE LACK OF KNOWLEDGE OF SITE CONDITIONS. JOB #4-15-005 Revised Plans received 11/06/2015 DBR 37 PLAN VERSION: 009.00.00 311465 / 434385 STORE NUMBER: GENERAL DRAWING SYMBOLS K. GRAPHIC AND WRITTEN INFORMATION ON DRAWINGS SHALL BE COORDINATED WITH ALL TRADES PRIOR TO INSTALLATION. BUILDING TYPE: SITE NUMBER: REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS FOR SPECIFIC SYMBOLS 09.21.15 PROJECT DIRECTORY GAS BUILDING DEPARTMENT CENTERPOINT 318.382.0315 CITY OF MINDEN 520 BROADWAY MINDEN, LA 71058 BRENT COOLEY 318.371.4215 ELECTRIC HEALTH DEPARTMENT 520 BROADWAY MINDEN, LA 71055 CITY OF MINDEN GARY MORLEN 318-453-7726 WEBSTER PARISH HEALTH UNIT 1200 HOMER ROAD, MINDEN, LA 71055 FLOYDE SMITH 318.371.3030 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 DBR 37 TITLE SHEET T1.0 NOTE: HATCHED AREA INDICATES PROPOSED PIZZA HUT TENANT SPACE. PROJECT GENERAL NOTES VICINITY MAP UTILITY CONTACTS KEY PLAN PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 EXIST. DEMISED WALL V.I.F. EXIST. 8" CMU WALL V.I.F. EXIST. 4x4 COL V.I.F. EXHAUST FANSEE MECH RESTROOM EXHAUST FANSEE MECH (BELOW) (BELOW) (2) 2X4 (BELOW) JOIST REINF. REQ'DSEE 8/S2.0 RTU-2 1300 lbs 9 S2.0 (2) 2X4 (BELOW) (2) 2X4 (BELOW) HSS4X2X41 LSH (BELOW) (2) 2X4 HSS4X2X41 LSH (2) 2X4 HSS4X2X41 LSH HSS4X2X41 LSH HSS4X2X41 LSH (2) 2X4 (BELOW) (2) 2X4 V.I.F. ANY DISCREPANCIES WITH ASSUMPTIONS MADE RESTROOM EXHAUST FANSEE MECH (BELOW) (2) 2X4 EXIST. 20" DEEP OPEN WEB JOISTS @ 5'-0" o.c. (20k5 ASSUMED) EXIST. W18 V.I.F. (W18X46 ASSUMED) EXHAUST FANSEE MECH (2) 2X4 EXIST. W18 V.I.F. (W18X46 ASSUMED) 8 S2.0 V.I.F. ANY DISCREPANCIES WITH ASSUMPTIONS MADE RTU-1 2500 lbs TYP SEE 5/S2.0 FOR DECK SUPPORT @ NEW OPENING EXIST. 24" DEEP OPEN WEB JOISTS @ 5'-0" o.c. (24k7 ASSUMED) JOIST REINF. REQ'DSEE 8/S2.0 V.I.F. ANY DISCREPANCIES WITH ASSUMPTIONS MADE 29'-11" V.I.F. EXIST. 12" DEEP OPEN WEB JOISTS @ 5'-0" o.c. EXHAUST FANSEE MECH HSS4X2X41 LSH EXIST. 4x4 COL V.I.F. (BELOW) (2) 2X4 (BELOW) EXIST. 8" CMU WALL V.I.F. EXIST. 4x4 COL VERIFY 5 THICKNESS 16 " MIN. 5 (HSS4X4X16 ASSUMED) 10 8" EXIST. 8" CMU WALL V.I.F. EXIST. 4x4 COL V.I.F. S2.0 W16X50+3/8" PL W16X31+3/8" PL B/STL EL.+10'-2" B/STL EL.+10'-2" 10 3 S2.0 8" 24'-0" V.I.F. S2.0 25'-421" V.I.F. OPP. HAND 18'-621" V.I.F. EXIST. 8" CMU WALL V.I.F. 3 S2.0 12'-3" V.I.F. CONTRACT DATE: WALL FRAMING PLAN A. B. GENERAL PROVISIONS: PROVIDE TEMPORARY SHORING AS REQUIRED DURING REINFORCING OF EXISTING JOISTS. THIS STRUCTURE HAS BEEN MODIFIED IN ACCORDANCE WITH THE 2012 INTERNATIONAL BUILDING CODE. MATERIALS AND SERVICES PROVIDED BY THE CONTRACTOR SHALL CONFORM TO THE ABOVE MENTIONED CODES AND THE CONTRACT SPECIFICATIONS. REMOVE LIVE LOAD FROM ROOF PRIOR TO AND DURING REINFORCEMENT OF EXISTING JOISTS. C. IF SECTION OF EXISTING BRIDGING REMOVED: ADD CROSS BRIDGING ON EITHER SIDE OF REMOVED SECTION. D. SEE "B" THIS SHEET FOR GENERAL STRUCTURAL NOTES. STRUCTURAL STEEL: WIDE FLANGE: ASTM A992 UNO PLATE, ANGLES, CHANNELS: ASTM A36 UNO TUBES: ASTM A500 GRADE B (Fy=46 ksi) DETAILING, FABRICATION, AND ERECTION SHALL CONFORM EXISTING ROOF CONSTRUCTION SHOWN ON THE DRAWINGS IS BASED ON WITH THE AISC "STEEL CONSTRUCTION MANUAL", 13TH A SITE SURVEY AND PHOTOS PERFORMED BY GPD GROUP. CONTRACTOR EDITION AND THE "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES" EXCEPT SECTION 4.2 OF THE CODE SHALL FIELD VERIFY ALL THE DIMENSIONS AND ALL EXISTING WHICH SHALL NOT BE APPLICABLE TO THIS PROJECT. CONSTRUCTION CONDITIONS PRIOR TO STEEL FABRICATION OR ORDERING MATERIALS AND COORDINATE ANY DISCREPANCIES WITH THE HOT-DIP GALVANIZING SHALL CONFORM WITH ASTM A123 ENGINEER. THE EXISTING ROOF CONSTRUCTION CONSISTS OF A MEMBRANE ROOF OVER RIGID INSULATION OVER 134" NARROW RIBBED METAL DECK OVER OPEN WEB METAL JOISTS (SEE PLAN FOR SPACING). FIELD VERIFY JOIST SIZE, OVERALL SPAN, AND DECK TYPE AND COORDINATE DISCREPANCIES WITH ENGINEER PRIOR TO ORDERING MATERIALS. GENERAL CONTRACTOR SHALL VERIFY ALL MECHANICAL EQUIPMENT LOCATIONS, OPENING DIMENSIONS AND WEIGHTS PRIOR TO STRUCTURAL STEEL FABRICATION. NOTIFY ENGINEER IF DIFFERENT FROM THAT SHOWN ON DRAWINGS. TOP OF EXISTING FLOOR SLAB = 0'-0". ALL OTHER ELEVATIONS ARE REFERENCED FROM THIS ELEVATION. ALL WELDING SHALL BE DONE USING E-70XX ELECTRODES IN ACCORDANCE WITH THE LATEST AWS SPECIFICATIONS. SEE ARCH. DRAWINGS FOR DIMENSIONS NOT SHOWN. FIELD VERIFY ALL CONDITIONS AT AND CONNECTIONS TO THE EXISTING CONSTRUCTION BEFORE FABRICATION. WHERE EXISTING CONDITIONS ARE CUT OR DISTURBED TO PERMIT INSTALLATION OF NEW WORK, MATCH AND PATCH EXISTING DISTURBED CONSTRUCTION TO ORIGINAL CONDITION. PRIME ALL STEEL NOT IN CONTACT WITH CONCRETE. CONCRETE WOOD: CONCRETE SHALL BE HARD ROCK CONC. (5 SACK CEMENT PER CU.YD. MIN.) AND MEET THE FOLLOWING MIN. ULTIMATE COMPRESSIVE STRENGTHS AT 28 DAYS: MATERIALS a. FRAMING LUMBER 2X6 AND LARGER SHALL BE SOUTHERN PINE NO. 1 USED AT A MAXIMUM MOISTURE CONTENT OF 19% WITH THE FOLLOWING MINIMUM ALLOWABLE STRESSES: Fb=1,650 PSI Fv= 90 PSI Fc=1,750 PSI E=1,700,000 PSI LOCATION MIN. STRENGTH 28 DAYS PSI AGGREGATE SIZE - INCHESS SLUMP INCHES TOLERANCE CONCRETE MIX DESIGN AND TESTING SHALL MEET WITH THESE SPECS. CEMENT SHALL BE IN ACCORDANCE WITH ASTM C 150 TYPE II. VERIFY MIN. CONC. STRENGTH AND CEMENT TYPE. REINFORCING STEEL SHALL CONFORM TO ASTM A-615, GRADE 60. STEEL SHALL BE KEPT CLEAN AND FREE OF RUST. DETAIL, FABRICATE AND ERECT STRUCTURAL WOOD IN ACCORDANCE WITH THE LATEST EDITON WITH THE NANTIONAL DESIGN SPECIFICATION FOR WOOD CONSTUCTION. WELDED WIRE REINFORCEMENT SHALL CONFORM TO ASTM A-185. ALL WOOD IN CONTACT WITH CONCRETE OR STEEL SHALL BE PERSERVATIVE TREATED. CONCRETE CURING SHALL BE IN ACCORDANCE WITH REQUIREMENTS OF ACI-318-08 SECTION 5.11 AND STANDARD PRACTICE FOR CURING CONCRETE REPORTED BY COMMITTEE 308. ALL BEAMS AND JOISTS SHALL BE CUT FOR FULL UNIFORM BEARING AT SUPPORTS. 1/4"=1'-0" A DESIGN LOADS: 09.21.15 BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: A. ROOF LIVE LOAD 20 PSF B. ROOF SNOW LOADS GROUND SNOW LOAD (Pg) 5 PSF EXPOSURE FACTOR (Ce) 0.9 IMPORTANCE FACTOR (I) 1.0 FLAT ROOF SNOW LOAD (Pf) 5 PSF MIN. THERMAL FACTOR (Ct) 1.0 C. WIND LOADS 3 SECOND GUST 90 MPH IMPORTANCE FACTOR 1.0 EXPOSURE CATEGORY C E. SEISMIC LOADS ANALYSIS NOT REQUIRED PER INTERNATIONAL BUILDING CODE 3404.4 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 DBR 37 ALL WOOD CONSTRUCTION CONNECTORS SHALL BE MANUFACTURED BY SIMPSON STRONG-TIE COMPANY AND SHALL BE FASTENED PER THE MANUFACTURER'S RECOMMENDATIONS. ROOF FRAMING PLAN S1.0 GENERAL SHEET NOTES C GENERAL STRUCTURAL NOTES B PLOT DATE: 3x3x1/4" ANGLE, TYP. PROVIDE ANGLES AS REQUIRED TO FRAME OPENING. PROVIDE JOIST STRUT AS REQUIRED. SEE TYPICAL JOIST LOAD STRUT DETAIL. 1 2" EXPANSION JOINT MATERIAL #4 DOWEL 1'-0"x1'-0" LG @16" O.C. #4 DOWEL 1'-0" LG @16" O.C. WITH HILTI HIT-HY200ADHESIVE 6" MIN EMBED. #4 DOWEL 1'-0" LG @16" O.C. WITH HILTI HIT-HY70 ADHESIVE 6" MIN EMBED. N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 3/16 "E" "E" T/FND WALL EL. -0'-8" JOIST JOIST PLAN VIEW 11 2 EX. FOOTING WHERE DIMENSION "E" IS LESS THAN 6" ANGLE MAY BE OMITTED. EXIST. ROOF DECK 3/16 REMOVE TOP COURSE OF WALL EX. CMU (ASSUMED) FOUNDATION WALL GROUT SOLID IF NOT GROUTED NOTE: TYPICAL ROOF OPENING DETAIL SHOWN APPLIES TO ALL ROOF OPENINGS WHERE LEAST DIMENSION IS 12" OR LARGER. REINFORCE ROOF OPENINGS LESS THAN 12" BY WELDING 16 GA. SHEET METAL 1'-0" WIDER THAN OPENING TO METAL ROOF DECK. NOT USED 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 T/SLAB EL. 0'-0" 6" TYP. EX. SLAB BEAMSEE PLAN EXIST. JOIST V.I.F. TYP BEAMSEE PLAN 2 3/16 TYP. ROOF OPENING DETAIL 3/16 3/4" = 1'-0" 5 SLAB REPAIR AT NEW STOREFRONT 3/4" = 1'-0" 1 2 MECH. UNIT STEEL SHIMS @ 2'-0" O.C. (NOT REQ'D IF TAPERED CURBS ARE PROVIDED) MECH. UNIT CURB SEE MECH'L DWGS CONT. MC6x15.3 HSS @ 6'-0" o.c.SEE PLAN FOR SIZE SIMPSON H6 SIMPSON H6 1/4 C6x8.2 1/4 #4x1'-0" @ 16" O.C. EA. SIDE, DOWEL INTO EXISTING SLAB w/HILTI HIT-HY200 (6" MIN. EMBED.) EA. BEAM 2 2x4 TYP U.N.O. EXISTING SLAB (3)-10d COMMON NAILS TYP. NOT USED 12 L REINFORCEMENT REQ'D WHEN GREATER THAN 6" 1/8 4" MIN. THICK CONCRETE INFILL ON VAPOR RETARDER AND 4" GRANULAR FILL W/ 6x6 2.9xW2.9 WWF CENTERED COMPACTED GRANULAR SUB-BASE UTILITY TRENCH 5 L121x121x16 EA SIDE TYP. RTU CURB SUPPORT DETAIL 3/4" = 1'-0" 6 TRENCH REPAIR DETAIL 4 S2.0 3/4" = 1'-0" 2 ADJUSTABLE MASONRY ANCHOR TIES @ 32" O.C. w/(1)-8" MAX FROM EA. END ANG. REINFORCEMENT REQ'D. WHEN GREATER THAN 6" 9'-6" PROVIDE OVERSIZED WASHERS 6" MAX. 1/2" FLAT SCREEN TVCOORD. w/ ARCH 7'-0" RODS W/ HILTI HIT-HY70 ADHESIVE (9" MIN EMBED) PL 1/2"x7"x0'-8"LG. 5 L121x121x16 EA. SIDE JOIST REINF. EQUIPMENT HANGER SUPPORT BY OTHERS 1/2" S.S. THREADED ROD TYP. U.N.O. S.S. WASHER & (2)-NUTS. PROVIDE GASKET IF HANGER IS OF DIFFERING MATERIAL GROUT MASONRY SOLID 16" DEEPx16" WIDE BELOW LINTEL BRG. CONTRACT DATE: MASONRY OPENING TYPICAL STEEL LINTEL BEARING DETAIL (LINTEL PARALLEL TO WALL) BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: NOT USED 13 SECTION 3/4" = 1'-0" 9 TYP. HANGER WEB REINF. DETAIL 3/4" = 1'-0" 7 TYP. LINTEL BEARING DETAIL 3/4" = 1'-0" 09.21.15 2015388.14 3 PIZZA HUT EXTENTS OF JOIST REINFORCING NEEDLE BEAM AS REQ'D 123 Minden Shopping Dr. Minden, LA 71055 MECH. UNIT. EXIST. COL PL21"x3"x8" SEE SECT. 6 THIS SHEET 1/4 8" SHORE EX. AS REQ'D 1/4 8" 1/4 8" SHORE EX. AS REQ'D EXISTING WALL TYP. 3/16 BEAMSEE PLAN EXIST. BEAM V.I.F. NOTES: 3 L121x121x16 JOIST WEB REINFORCEMENT (NEAR SIDE & FAR SIDE. ALTERNATE SIDES.) 3 L121x121x16 JOIST CHORD REINF. SEE DETAIL 6 THIS SHT. PROVIDE NEW MASONRY TO MATCH EXISTING 14 SECTION 3/4" = 1'-0" 10 4-12 1/4" TYP. U.N.O. EX. JOIST V.I.F. JOIST PROFILE SHOWN IS FOR CONCEPTUAL USE ONLY. ACTUAL NUMBER OF WEB MEMBERS THAT REQUIRE REINFORCEMENT SHALL BE FIELD VERIFIED. NOT USED DBR 37 NON-SHRINK GROUT FOR UNIFORM BEARING TYP. LINTEL BEAM. SEE PLAN S2.0 CONT BOT. PL 7x3/8 SECTION 3/4" = 1'-0" 8 SLAB & FRAMING DETAILS SECTION 3/4" = 1'-0" 4 PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 SS 7 1 2 9 12 13 CW 3 18 10 4 5 6 9 11 12 14 8 15 17 12 16 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. THESE DRAWINGS WERE PREPARED BASED ON INFORMATION ATTAINED FROM A SITE SURVEY AND AS-BUILT DRAWINGS. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS IN FIELD PRIOR TO DEMOLITION AND NOTIFY THIS OFFICE IN CASE OF DISCREPANCIES ASAP. DEMOLITION IS TO BE EXECUTED SO AS NOT TO DISTURB EXISTING STRUCTURAL AND ROOFING SYSTEMS, AND OTHER AREAS THAT ARE INTENDED TO REMAIN INTACT. VERIFY ALL CONSTRUCTION TO BE REMOVED THAT IS NOT INTEGRAL TO STRUCTURAL SYSTEM PRIOR TO DEMOLITION. ALL DIMENSIONS SHOWN AS EXISTING SHOULD BE FIELD VERIFIED BY CONTRACTOR PRIOR TO DEMOLITION. VERIFY ALL DEMOLITION WORK WITH NEW CONSTRUCTION AND INSTALLATION DRAWINGS PRIOR TO BEGINNING CONSTRUCTION. DEMOLITION CONTRACTOR TO COORDINATE AND REVIEW ALL CONSTRUCTION DOCUMENTS AND DETERMINE THE EXTENT OF DEMOLITION WORK AND BECOME FAMILIAR WITH THEM THOROUGHLY BEFORE PERFORMING ANY DEMOLITION WORK. BY THE ACT OF STARTING DEMOLITION, THE CONTRACTOR WILL BE DEEMED TO HAVE COMPLIED WITH THE FOREGOING, TO HAVE ACCEPTED SUCH CONDITIONS, AND TO HAVE MADE THE NECESSARY ALLOWANCES IN PREPARING HIS BID. VERIFY DISPOSITION OF ALL FURNISHINGS, MILLWORK, LIGHTING FIXTURES, EQUIPMENT, ETC. TO BE REMOVED WITH OWNER AND/OR LANDLORD. ALL ITEMS TO BE DISPOSED SHALL BE DISPOSED OF OFF-SITE AND IN AN EXPEDITIOUS MANNER. WHEN UTILITIES ARE REMOVED, CAP AND SEAL A MINIMUM OF 6" ABOVE FINISH CEILING. SAWCUT AND REMOVE EXISTING SLABS AS REQUIRED FOR UNDERGROUND ELECTRICAL AND PLUMBING LINES. ALL CONCRETE FLOOR WORK TO BE FINISHED FLUSH WITH EXISTING FLOOR. REPLACE OR REPAIR ANY VAPOR BARRIERS DISTURBED DURING EXCAVATIONS. VERIFY EXTENT OF WORK WITH KITCHEN EQUIPMENT MANUFACTURER. CONTRACTOR SHALL PROVIDE ALL TEMPORARY BRACING AS REQUIRED TO MAINTAIN STRUCTURAL STABILITY OF THE EXISTING STRUCTURE DURING ALL PHASES OF CONSTRUCTION. PROTECT FROM DAMAGE DURING CONSTRUCTION ALL EXISTING WALLS, FLOORS, CEILINGS, ETC. THAT ARE TO REMAIN. CONTRACTOR TO PATCH AND REPAIR ANY DAMAGED PORTIONS OF THE EXISTING BUILDING AS REQUIRED TO MATCH THE EXISTING ADJACENT CONSTRUCTION AND FINISHES. THIS PLAN INDICATES A GENERAL SCOPE OF WORK TO BE PERFORMED AND DOES NOT RELIEVE THE CONTRACTOR TO COMPLETE THE BUILDING MODIFICATIONS AS SHOWN AND REQUIRED BY THE CONTRACT DOCUMENTS, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL AND HVAC WORK. IF CONTRACTOR ENCOUNTERS ANY HAZARDOUS MATERIALS DURING DEMOLITION OR CONSTRUCTION, HE SHALL IMMEDIATELY SUSPEND WORK AND NOTIFY THE PIZZA HUT CONSTRUCTION MANAGER BEFORE PROCEEDING. ALL DEMOLITION SHALL BE CARRIED OUT IN A SAFE MANNER AND IN STRICT ACCORDANCE WITH LOCAL REGULATIONS. THE SUB-CONTRACTOR SHALL FIELD VERIFY THE EXTENT OF DEMOLITION. THE WORK INCLUDES, BUT IS NOT LIMITED TO THE DEMOLITION AND REMOVAL OF ANY WALLS, COUNTERS, FURNITURE, BULKHEADS, DOORS, PLUMBING, MECHANICAL AND ELECTRICAL ITEMS INCLUDING CONDUITS AND DUCTWORK AS SHOWN ON THE DRAWINGS OR AS REQUIRED TO COMPLETE THE INSTALLATION OF THE NEW WORK FOR A COMPLETE JOB. REMOVE ANY SINKS, WATER CLOSETS, URINALS, LAVATORIES, FLOOR DRAINS, NOTED ON DRAWINGS AS WELL AS ALL ASSOCIATED PLUMBING ACCESSORIES. CAP, PLUG ALL ABANDONED SUPPLY AND WASTE LINES. PATCH AND SEAL ALL FLOOR PENETRATIONS. ALL DEVICES REMOVED DURING DEMOLITION SHALL HAVE ALL ASSOCIATED CONDUIT, WIRING, AND CONTROLS REMOVED BACK TO SOURCE OR NEXT DEVICE THAT REMAINS. RE-FEED ANY ELECTRICAL DEVICE OR ITEM THAT IS EXISTING TO REMAIN WHOSE WIRING IS INTERRUPTED DUE TO RENOVATION IN ADJACENT AREA. ANY ELECTRICAL DEVICE THAT IS TO REMAIN THAT IS LOCATED ON OR IN A WALL OR CEILING BEING REMOVED SHALL BE RELOCATED AS DIRECTED BY G.C. IN FIELD AND RECONNECTED AS REQUIRED. GENERAL DEMOLITION NOTES DEMO FLOOR PLAN 1 REMOVE PLUMBING FIXTURES IN THEIR ENTIRETY. CAP UNUSED PLUMBING LINES BELOW FLOOR/BEHIND WALLS. 2 REMOVE EXISTING WATER HEATER IN ITS ENTIRETY. TERMINATE ALL PLUMBING AS REQUIRED FOR NEW CONSTRUCTION. 3 DOOR AND FRAME TO REMAIN. 4 REMOVE ALL INTERIOR PARTITIONS TERMINATE ALL WIRING BACK TO SOURCE. CAP EXISTING PLUMBING AS REQUIRED FOR NEW CONSTRUCTION. 5 1/4"=1'-0" A CONTRACT DATE: REMOVE CEILING FINISHES, LIGHT FIXTURES AND ASSOCIATED WIRING (BACK TO SOURCE), DIFFUSERS, AND SOFFITS. BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: REMOVE EXISTING FLOOR FINISHES. PREPARE EXISTING CONCRETE FLOOR WITHIN THE ENTIRE SPACE AND PATCH EXISTING FLOOR TO RECEIVE NEW FINISHES. 7 EXISTING SANITARY LINE LOCATION. DEPTH AT 32" BELOW FINISHED FLOOR. 8 REMOVE EXISTING ELECTRIC PANEL AND ALL ASSOCIATED BRANCH WIRING. 9 REMOVE EXISTING WATER SUPPLY LINES BACK TO INCOMING WATER LINE. A. B. 10 REMOVE EXISTING RTU AND ALL ASSOCIATED SUPPLY AND RETURN AIR DUCTWORK IN ITS ENTIRETY. C. 11 REMOVE EXISTING DOOR AND FRAME. 12 SAWCUT EXISTING CONCRETE SLAB AS SHOWN HATCHED FOR THE INSTALLATION OF NEW PLUMBING LINES AS INDICATED ON DRAWING P2.0. 13 EXISTING 1" WATER LINE SERVICING TENANT SPACE. 14 WHERE NEW MECHANICAL EQUIPMENT OCCURS, CREATE NEW ROOF OPENINGS, PATCH/FLASH ROOF AT CURBS AS REQUIRED. 15 REMOVE EXISTING ROOFTOP UNIT, ROOF CURB. REPAIR ROOF DECK, RIGID INSULATION AND ROOFING TO MATCH EXISTING. 16 REMOVE EXISTING CMU WALL AS REQUIRED FOR NEW STOREFRONT. SEE SHEET A1.0. 17 MODIFY EXISTING STOREFRONT. SEE SHEET A1.0 & A1.1. 18 EXISTING STOREFRONT TO BE REMOVED. SAVE FOR RELOCATION. D. 123 Minden Shopping Dr. Minden, LA 71055 DO NOT SCALE DRAWINGS DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS NOTED OTHERWISE (U.N.O.) WHERE EXISTING CONDITIONS ARE CUT OR DISTURBED TO PERMIT INSTALLATION OF NEW WORK, MATCH & PATCH EXISTING DISTURBED CONSTRUCTION TO ORIGINAL CONDITION. BUILDING ELEMENTS SHOWN WITHOUT ANY KEYNOTE, ARE EXISTING TO REMAIN, U.O.N. DEMOLITION PLAN NOTES E DBR 37 DEMO PLAN EXISTING WALL TO REMAIN KEY NOTES 2015388.14 PIZZA HUT EXISTING TO BE REMOVED D 311465 / 434385 STORE NUMBER: 6 09.21.15 C D1.0 WALL TYPES N.T.S. B PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 10'-141" 9'-10" 15 7'-1141" 9'-541" 16'-341" 13'-141" 2 GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL BUILDING DIMENSIONS PRIOR TO BEGINNING CONSTRUCTION AND SHALL IMMEDIATELY NOTIFY OWNER'S REPRESENTATIVE OF ANY VARIANCE OR DISCREPANCY AFFECTING NEW CONSTRUCTION PRIOR TO PROCEEDING WITH WORK. 2'-941" 15 13 17 15 18 6 9 A11.3 2x6 A10.1 2 A11.3 1 A11.1 22 3 6 5 321" COOLER 9'-11" 3" 12'-94 3 A10.0 2 4 A10.0 8 A11.3 A10.1 1 18 A10.0 22 4 1 9 A11.3 7'-741" 7'-121" 5'-6" DINING 2x6 FREEZER A10.1 1 A5.0 10 321" 14. ALL MEANS OF EGRESS AND FIRE PROTECTION SHALL BE MAINTAINED AT ALL TIMES AND ANY SHUT DOWN OF LIFE SAFETY OR BUILDING SYSTEMS SHALL BE APPROVED AND COORDINATED IN ADVANCE WITH THE OWNER AND LOCAL BUILDING DEPARTMENT. 2 5 6 13. UPON COMPLETION OF PROJECT, GENERAL CONTRACTOR TO OBTAIN ALL FINAL INSPECTIONS AS REQUIRED BY LOCAL JURISDICTIONS AND FURNISH OWNER WITH EVIDENCE OF ALL SUCH INSPECTIONS AND CERTIFICATES OF OCCUPANCY. A10.1 4 2x4 11. ALL PENETRATIONS SHALL RECEIVE CAULKING TO SEAL ANY TYPE OF ENERGY LOSS. 12. THE DRAWINGS ARE NOT TO BE SCALED. FOR INFORMATION CONCERNING EXISTING PARTITIONS, ETC., VERIFICATION MUST BE DONE IN THE FIELD. 2 A11.1 19 1 10. GENERAL CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING IN WALLS FOR SUPPORT OF ALL EQUIPMENT, SHELVING, ACCESSORIES SEE FLOOR PLAN FOR LOCATION OF BLOCKING. 3 A11.1 14 18 8 GENERAL CONTRACTOR SHALL COORDINATE EXISTING STRUCTURE WITH NEW CONSTRUCTION INCLUDING MECHANICAL, PLUMBING, FIRE PROTECTION AND ELECTRICAL WORK. 10'-11" 2'-8" 9 3'-041" 3'-1" SERVICE 15 17 21 5 3'-341" 7'-0" 3'-6" 7 A10.1 18 7 2 12 A10.2 7 11'-1121" 9. 12 4'-421" 8. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF THE BUILDING'S STRUCTURAL SYSTEM. STRUCTURAL MEMBERS, INCLUDING BEARING AND SHEAR WALLS, SHALL NOT BE REMOVED, CUT OR OTHERWISE MODIFIED WITHOUT WRITTEN AUTHORIZATION FROM THE OWNER'S REPRESENTATIVE. DRY STORAGE 11 321" 12 5'-1041" 7. 12 PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION, GENERAL CONTRACTOR SHALL VERIFY EXISTENCE AND LOCATION OF ALL EXISTING ABOVE AND BELOW GRADE UTILITIES,INCLUDING SANITARY SEWER, STORM SEWER, WATER, GAS, ELECTRICAL, TELEPHONE, ETC. ANY DISCREPANCIES IN UTILITY LOCATIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE OWNER'S REPRESENTATIVE. 16'-021" 6 2x6 6. 6 10'-53 4" 16 13'-2" 3'-6" ALL REMODELED BUILDING ELEMENTS INCLUDED AS PART OF THIS PROJECT SHALL COMPLY WITH THE MOST CURRENT EDITION OF BUILDING CODES, AND LOCAL CODES. 11'-121" 5. 3'-0" 16 1 2'-8" ALL WORK SHALL BE IN COMPLIANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL BUILDING CODES, REGULATIONS, ORDINANCES AND STANDARDS. 2'-8" 4. 20 10'-10" CUT, REMOVE AND REPLACE EXISTING CONCRETE SLAB AS REQUIRED FOR INSTALLATION OF NEW UNDER SLAB PIPING AND CONDUIT. 5'-921" 3. 3" 1'-104 PREPARE EXISTING CONCRETE SLAB TO RECEIVE NEW FLOOR FINISHES AS SCHEDULED. 7'-941" 2. 5'-5" REPLACE OR REPAIR DAMAGED, DETERIORATED OR UNSUITABLE SUBSTRATES AS REQUIRED TO RECEIVE NEW WALL FINISHES AS SCHEDULED. 2x6 1. 3 3 4 A11.1 3 3" 43'-104 4 15. DEMISING WALLS SHALL EXTEND FULL HEIGHT TO STRUCTURE ABOVE. G.C. SHALL SEAL ALL PENETRATIONS AS REQUIRED TO MAINTAIN INTEGRITY OF DEMISING WALLS AND PREVENT INSECT OR RODENT EGRESS INTO STORE SPACE. 12'-23 4" CONTRACT DATE: 16. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF EXISTING INSULATION VALUES IN EXTERIOR WALL AND ROOF/CEILING ASSEMBLY. CONTRACTOR SHALL PROVIDE ADDITIONAL INSULATION TO ACHIEVE A MINIMUM R-19 IN EXTERIOR WALLS AND R-30 IN ROOF/CEILING ASSEMBLY. 09.21.15 BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: 2015388.14 PIZZA HUT 17. ALL DIMENSIONS TO FINISHED WALL UNLESS OTHERWISE NOTED. PROJECT GENERAL NOTES F TYPICAL EXTERIOR WALL: EXISTING CMU WALL W/ 2X4 WOOD STUDS @ 16" O.C. TO DECK IN OPEN CEILING AREAS, 2X4 WOOD STUDS @ 16" O.C. TO 6" ABOVE CEILING @ RESTROOMS AND B.O.H. INSULATE STUD CAVITIES WITH R-13 FIBERGLASS BATT INSULATION. TYPICAL INTERIOR WALL: 2x4 WD STUDS AT 16" O.C. (2x6 WHERE NOTED) TO DECK IN OPEN CEILING AREAS, 2X4 WD STUDS @ 16" O.C. TO 6" ABOVE CEILING @ RESTROOMS AND B.O.H. W/ 1/2" TYPE "X" GYP. BD. SUBSTRATE U.O.N. USE MOISTURE RESISTANT GYP. BD. BEHIND ALL CERAMIC WALL TILE. U.O.N. PROVIDE 3 1/2" SOUND BATT INSULATION AT ALL RESTROOM WALLS. FLOOR PLAN DASHED LINE INDICATES SUBSTRATE LOCATION. ALL WALLS SHALL BE AS INDICATED EXCEPT FROM TOP OF SLAB TO 12" ABOVE SLAB SHALL BE 1/2" CEMENT BOARD, U.O.N. THIS NOTE DOES NOT APPLY TO EXTERIOR FACE OF EXTERIOR WALLS. TYPICAL INTERIOR LOW WALL: 2X4 STUDS AT 16" O.C. (2X6 OR 2X8 WHERE NOTED) W/ 1/2" GYP. BD. SUBSTRATE U.O.N. T.O. WALL AT 4'-0" A.F.F. U.N.O. DIMENSIONS: A. ALL DIMENSIONS ARE TO FACE OF STUD U.O.N. REFER TO FOUNDATION PLAN FOR FACE OF CONC. DIMENSIONS. B. DIMENSIONS NOTED AS CLEAR ARE MIN. REQ'D. NET CLEARANCE FROM FACE OF WALL / WAINSCOT FINISH. REFER TO DWG A2.0 FOR CRITICAL "HOLD" EQUIPMENT CLEARANCES. VERIFY FINAL EQUIPMENT SIZES W/ VENDOR PRIOR TO INT. WALL FRAMING. WINDOWS / DOORS: A. SEE SHT. A1.1 FOR WINDOW TYPES AND DOOR SCHEDULE. B. ALL DOOR AND WINDOW OPENING DIMENSIONS ARE TO ROUGH OPENING. FINISH SUBSTRATES: A. PROVIDE 1/2" THICK CEMENTITIOUS BD. FROM FLOOR SLAB TO 12" A.F.F. MIN. IN LIEU OF GYP. BD. U.O.N. B. ALL JOINTS, GAPS OR SPACES LEADING TO ALL HOLLOW OR INACCESSIBLE SPACES SHALL BE SEALED WITH "NSF INTERNATIONAL" APPROVED SEALANTS. C. SEE SHTS. A8.0 AND A10.0 THRU A10.2 FOR ROOM FINISHES. D. ALL BACK OF HOUSE WALLS SHALL HAVE 1/2" EXPOSURE 1 PLYWD U.O.N. DECOR: A. SEE A2.0 FOR SEATING PLAN AND DETAILS. B. SEE A8.0 FOR FLOOR FINISHES. C. SEE A10.0 - A10.2 FOR WALL FINISHES. D. SEE A9.0 FOR CEILING FINISHES. WALL LEGEND D FLOOR PLAN NOTES 1 STARTING POINT. ALL SUB-TRADES SHALL USE THIS POINT AS A BEGINNING LAY-OUT (OUTSIDE FACE OF EXT. WALL STUDS). 2 INSTALL BACKER ROD AND SEALANT BETWEEN COOLER/FREEZER AND ADJACENT WALL SURFACES. DISCONTINUE WALL COVERING BEHIND COOLER / FREEZER. 1/4"=1'-0" A 13 BUNDLED SYRUP LINES IN 8" PVC CHASE BELOW SLAB FOR DRINK SYSTEM. 14 SAFE PEDESTAL, SEE DETAIL 19/A11.0 15 S.S. CORNER GUARD / WALL CAP, TYP. ALL CORNERS IN BACK-OF-HOUSE FROM REAR WALL TO THE KITCHEN SIDE OF THE SERVICE COUNTER. SEE DETAIL 15/A11.0. 16 HOOD AT THIS WALL REFERENCE MECHANICAL. OWNER SUPPLIED AND CONTRACTOR INSTALLED S.S. PANELS. APPLY WITH CONSTRUCTION ADHESIVE NO EXPOSED SCREWS/ATTACHMENTS. 3 EXISTING BUILDING COLUMN. 4 DEMO CMU WALL AS REQUIRED FOR INSTALLATION OF NEW STOREFRONT. SEE STRUCTURAL DRAWINGS. 5 CONTINUE B.O.H FINISHES INTO WALK IN COOLER AND UNDER FREEZER. 17 6 3/4" PLYWOOD BACKING BEHIND WALL MOUNTED HAND SINKS 18 HATCHED AREAS INDICATE MILLWORK. SEE SCOPE OF WORK. 7 ALUMINUM THRESHOLD. REF. SHEET DOOR HARDWARE SCHEDULE SHEET A1.1 19 LOW WALL. SEE DETAIL - 10/A11.3. 8 FIRE EXTINGUISHERS (PER LOCAL CODE) TO BE FURNISHED AND INSTALLED BY G.C. CONFIRM LOCATIONS WITH FIRE MARSHAL. 20 EXISTING TENANT SEPARATION WALL TO REMAIN.. MOP SINK LOCATION. 21 9 INSTANTANEOUS WATER HEATERS MOUNTED ABOVE CEILING . SEE PLUMBING SHEETS. 10 FREEZER FLOOR AND BASE FURNISHED BY MANUFACTURER. 11 ELECTRICAL PANELS AND CLEAR FLOOR SPACE. 12 SPLASH GUARD. SEE DETAIL 11/A11.0. DBR 37 FLOOR PLAN 22 A1.0 SUPPORT. C 123 Minden Shopping Dr. Minden, LA 71055 KEY NOTES B PLOT DATE: BUTTS LOCKS CLOSERS KICKPLATE DOOR STOP THRESHOLD 2 3 4 1 2 3 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 X X X X X X - - - 8, 9, 11, 12 3 EX. 3'-0" x 7'-0" x 1-3/4" - HM HM - - - 7, 10, 11, 16 4 3'-0" x 6'-8" x 1-3/4" B WD HM X X X X X X X 14/A11.0 14/A11.0 - 6, 11, 12, 13, 15, 17 5 3'-0" x 6'-8" x 1-3/4" B WD HM X X X X X X X 14/A11.0 14/A11.0 - 6, 11, 12, 13, 15, 17 X VISTA # TH43 I.D.C. 652-P X DOOR SIGN AL AL COAT HOOK - IVES 571-A92 A UNDERCUT 3/4" 3'-0" x 7'-0" x 1-3/4" 2 SWEEP (VISTA 231 STD) NGP 101VA 8, 9, 11, 12 QUALITY W302-26D - FLOOR STOP - QUALITY 433ES - STAINLESS STEEL 18" x 34" - STAINLESS STEEL 10" x 22" X STAINLESS STEEL 10" x 34" X X DOORMAN D-1550 X 3'-0" x 7'-0" x 1-3/4" FALCON #D271A X 1 CONT. HINGE MCKINNEY 300 SERIES X 1 1/2 PR VISTA STADARD BH-1 SILL 1 JAMB 4 HEAD 3 SURFACE BOLTS TOP & BOTTOM IVES SB1600 2 PROVIDE A SIGN STATING "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS" 1 SWEEP & WEATHERSTRIP INCL. IN PACKAGE 3 PULL 2 PULL PLATE #1610A 4" x 16" - QUALITY S.S. 1 PUSH 6 PUSH PLATE #40 8"x16" - QUALITY S.S. 5 HINGE STOP - STANLEY 76 6327 (US26) 4 NORTON 1604 OVERHEAD 3 PEMKO COMMERCIAL THRESHOLD - ALUM. 2 PANIC HARDWARE INCLUDED IN PACKAGE 1 1/2 PR McKINNEY #TA2731, 4-1/2" x 4-1/2" FRAME DOOR TYPE 1 X KICKPLATE PUSH SIDE ONLY DOOR TYPES 1/4" = 1' - 0" 3 GLASS SCHEDULE 1. SEE SCHEDULE FOR GLASS TYPES. 2. REFER TO FLOOR PLAN, ELEVATIONS AND WALL SECTIONS FOR ROUGH OPENING DIMENSIONS. A 1" INSULATED GLASS B REFERENCE NOTES: 1. STAIN/PAINT ALL DOORS AND FRAMES EXCEPT ALUMINUM ENTRY DOORS, 1 & 2. 1" INSULATED TEMPERED GLASS ALL STOREFRONT MATERIAL AND GLAZING SHALL BE SUPPLIED AND INSTALLED BY G.C. U.O.N. 4. ALL ALUMINUM DOOR AND WINDOW FRAMES SHALL BE DARK BRONZE ANODIZED. 5. REFER SPECIFICATIONS FOR GLASS & ALUM. STOREFRONT. 2. ALL HARDWARE SHALL BE US32D U.O.N. 3. ALL HM FRAMES SHALL BE 16 GA STEEL U.O.N. 4. ALL LOCKS SHALL BE FALCON 6 PIN INTERCHANGEABLE CORE SUPPLIED AND INSTALLED BY THE G.C. ALL EXTERIOR LOCKS SHALL BE PROVIDED WITH CONSTRUCTION CORES. ALL PERMANENT CORES SHALL BE KEYED ALIKE. 5. PERMANENT CORES SHALL BE SHIPPED TO THE RESTAURANT GENERAL MANAGER. 6. MOUNT DOOR CLOSURES ON TOILET ROOM OR KITCHEN SIDE ONLY. NOTE: SHADING COEFFICIENT SPECIFICATION PER LOCAL CODE REQUIREMENTS. DAYTIME VISIBILITY INTO DINING ROOM SHALL BE MAINTAINED. 9. DOOR SCHEDULE 2 DOOR SCHEDULE NOTES 1 IF REQUIRED BY LOCAL CODE, STOREFRONT DOOR PANIC HARDWARE SHALL BE : DOR-O-MATIC 2092 RIM PANIC HARDWARE AND EXTERIOR PULLS WITH QUALITY #520 DOOR PULL. 10. EXISTING H.M. DOOR AND FRAME TO REMAIN. PROVIDE NEW HARDWARE. 11. MAXIMUM DOOR OPERATING PRESSURE : 5 LBS INTERIOR : 8.5 LBS EXTERIOR MEASURED AT 90 DEGREES TO THE DOOR AT THE STRIKE EDGE. 12. ADA COMPLIANT ACCESSIBILITY SIGNAGE WHERE REQUIRED - (1) MEN; (1) WOMEN; (2) EXIT. 13. RESTROOM SIGN IF REQUIRED. VERIFY LOCAL REQUIREMENTS. 7. KEYLESS ENTRY SYSTEM REQUIRED. INCLUDES PANIC HARDWARE, AND KEYLESS ENTRY, ORDERED THRU LOCKNET SECURITY DOORS, (1-800-887-4307). 8. PROVIDE PUSH/PULL BARS. (ROCKWOOD GEOMETEK #RM7902 16" MOUNT VERT. "PULL") (#RM7902 36" MOUNT HORIZ. "PUSH") 14. NOT USED. 15. DOORS AND FRAMES SHALL BE PAINTED, SEE FINISH SCHEDULE SHT A8.1 16. PROVIDE WIDE ANGLE PEEP HOLE AT 48" A.F.F. GENERAL NOTES 17. DOORS SHALL BE PAINT GRADE. 4 N.T.S. REMOVE GLAZING AND SWAP POSITIONS B B 2 A7.0 8 A11.0 A A A B 3'-1" 2 A7.0 A A 2 A7.0 CONTRACT DATE: 8'-1" 6'-11" B A B B DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: A 3'-2" 7'-0" B B 311465 / 434385 1'-4" 3'-0" 3'-4" 4'-8" B 6'-4" B 6'-621" B B 5'-821" 6'-4" B B 1'-421" 6'-4" B 3'-0" 1'-421" 3" 43'-114 5 A7.0 1 A7.0 2 DARK BRONZE ANODIZED ALUMINUM (MATCH EXISTING) 1 A7.0 2015388.14 B B B 09.21.15 BUILDING TYPE: STORE NUMBER: 2'-0" 3. 4 FALCON C952 OR C986 AS REQUIRED 5'-4" 3'-0" 1'-0" DARK BRONZE ANODIZED ALUM. DOOR 3 DOOR NOTES X B DOOR PULL 2 DETAIL LOCATIONS AL AL SIGN WHERE NOTED DOOR PULL & PUSH PLATE 1 MISCELLANEOUS A SEE DOOR TYPE ELEVATIONS 4" 4" 4" DOOR SIZE PAIR N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F DOOR NO. 5 A7.0 1 A7.0 EX. EX. EX. EX. EXISTING STOREFRONT SYSTEM TO REMAIN B 3'-0" EX. EX. EX. EX. PIZZA HUT EX. EX. EX. EX. 123 Minden Shopping Dr. Minden, LA 71055 EXISTING STOREFRONT SYSTEM TO REMAIN 1 DARK BRONZE ANODIZED ALUMINUM (MATCH EXISTING) DBR 37 WINDOW NOTES ALL WINDOW ARE TO BE GLAZED W/ TYPE OTHERWISE. A GLASS UNLESS NOTED ROLLER SHADES TO BE FURNISHED AND INSTALLED BY G.C. ON ALL WINDOWS WITH SOUTHERN EXPOSURE. INDICATES LOCATION OF ROLLER SHADES NOTE: MOUNT ROLLER SHADES INSIDE FRAMES. DOOR & WDW ELEVATIONS/ SCHEDULE ROLLER SHADES: SUPPLIER: BLIND EXPRESS HUNTER DOUGLAS - ROLLERSHADE SHEAR WEAVE 4100, COLOR: V10 EBONY, 10% OPENNESS MOUNTED TO INSIDE OF WINDOW FRAME PHONE: 770.644.1688 A1.1 ROLLER SHADES TO BE FURNISHED AND INSTALLED BY G.C. WINDOW TYPES 1/4" = 1'-0" 5 PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 E D K-959 K-XX1 DELIVERY B-915 F-930 U-909 F-270 F-911 K-879 F-907 F-023 F-095 F-085 F-070 K-925 S-600 S-590 K-959 R-905 K-870 N-062 B-242 B-252 B-295 N-923 B-405 K-968 DRY STORAGE K-893 P-803 K-926 B-915 K-968 F-043 F-031 K-870 B-295 N-062 N-923 B-242 B-405 B-252 K-870 N-062 B-242 B-252 B-295 N-923 B-405 K-012 K-013 R-400 K-968 F-178 U-901 S-457 F-922 S-663 L-947 BELOW U-910 U-904 E-939 E-938 C-951 U-904 P-097 U-904 K-886 B-405 K-968 SHELVING ALONG BACK SIDE OF BULKHEAD (GC TO PROVIDE BLOCKING) N-062 B-295 B-252 B-242 SERVICE DIGITAL MB DIGITAL MB DIGITAL MB R-011 F-178 S-457 S-663 (3) F-922 U-901 L-909 L-910 DISHWASH S-580 S-927 K-926 B-406 B-242 B-265 B-295 N-134 W-XX1 K-XX3 12 10 10 10 10 10 11 B MEN 3 5 5 8 5 3 15 L-907 DINING L-905 L-907 B-300 11 L-906 3 B-406 S S S B-242 B-265 B-295 N-134 WOMEN K-XX3 FREEZER S B-275 B-305 B-300 COOLER K-XX2 C B-405 R-100 14 SHELVING ALONG BACK SIDE OF BULKHEAD (GC TO PROVIDE BLOCKING) F-265 1 2 CONTRACT DATE: 12 10 11 9 8 6 7 5 3 4 2 EQUIPMENT/SEATING PLAN X QTY. ITEM REMARKS 1 4 48" SINGLE DBR BOOTH -- 2 6 48" DOUBLE DBR BOOTH -- 3 3 30" x 48" LAMINATE TABLE TOP ACCESSIBLE BASE 4 7 30" x 48" LAMINATE TABLE TOP 5 3 6 DRY STORAGE SHELVING CALCULATIONS REMARKS EQUIPMENT # 1/4"=1'-0" A TOTAL EQUIPMENT # QUANTITY X FACTOR X LENGTH = 1.0 X .40 X 4.0 = 1.6 K-926 5.0 X .75 X N/A = 3.0 K-658 1.0 X 1.0 X 6.0 = 6.0 K-920 1.0 X 1.25 X 3.0 = 3.75 K-659 1.0 X 1.0 X 3.0 = 3.0 K-922 2.0 X 1.25 X 6.0 = 15.0 -- K-870 2.0 X .33 X 2.0 = 1.32 K-983 3.0 X 1.25 X 5.0 = 18.75 36" X 36" WOOD TABLE TOP BAR HEIGHT BASE K-919 1.0 X 1.0 X 5.0 = 5.0 5 30" x 48" WOOD TABLE TOP ACCESSIBLE BASE K-944 4.0 X 1.0 X 4.0 = 16.0 7 3 30" X 24" DWODO TABLE TOP -- K-970 1.0 X .66 X 2.0 = 1.32 8 1 30" x 96" WOOD TOP COMMUNITY TABLE ACCESSIBLE BASE K-982 1.0 X 1.25 X 5.0 = 6.25 9 8 DBR SOFT SEATING BAR HEIGHT K-983 3.0 X 1.25 X 5.0 = 18.75 10 22 DBR WOOD SEATING BAR HEIGHT 11 6 DBR WOOD SEATING -- 12 1 18" X 90" BENCH -- 14 5 48" FLAT SCREEN TV WALL MOUNT 15 1 60" FLAT SCREEN TV WALL MOUNT K-999 2.0 X 1.25 6.0 = 15.0 TOTAL HC NOT USED E KEY NOTES 311465 / 434385 STORE NUMBER: 2015388.14 123 Minden Shopping Dr. Minden, LA 71055 DBR 37 QUANTITY X FACTOR X LENGTH = TOTAL K-659 1.0 X 1.0 X 3.0 = 6.0 K-922 2.0 X 1.25 X 5.0 = 12.5 18.5 ACCESSIBLE SEATING EQUIPMENT PLAN A2.0 **DO NOT INCLUDE SPEED RACK F 009.00.00 40.5 FREEZER SHELVING CALCULATIONS TOTAL DECOR 1. REFER TO SCOPE OF WORK FOR RESPONSIBILITIES. SEATING PACKAGE - BY SEATING VENDOR U.O.N. X PLAN VERSION: TOTAL K-323 EQUIPMENT # DBR 37 PIZZA HUT COOLER SHELVING CALCULATIONS QUANTITY X FACTOR X LENGTH = BUILDING TYPE: SITE NUMBER: 1 09.21.15 D TOTAL 74.24 STORAGE CAPACITY MATRIX B PLOT DATE: EQUIPMENT SCHEDULE NO. QTY B-242 B-252 B-265 B-275 B-295 B-300 B-305 B-310 B-400 B-405 B-406 B-410 B-643 4 2 2 2 5 2 2 2 1 5 2 1 1 B-915 2 BY G.C. SUPPLY INST. X X X X X X X X X X X X X ITEM DESCRIPTION B CONTRACTOR BUILDING ELEMENTS SOAP DISPENSER (WALL MOUNT) SANITIZER DISPENSER MIRROR, 18" x 36" TOILET PAPER DISPENSER PAPER TOWEL DISPENSER GRAB BAR 1-1/2"DIA X 36" S.S. FIN. GRAB BAR 1-1/2"DIA X 42" S.S. FIN. VERTICAL GRAB BAR 1-1/2"DIA X 18" S.S. FIN. WASTE BASKET - 32 GALLON WASTE BASKET WASTE BASKET SANITARY NAPKIN DISPOSAL KAY CHEMICALS DISPENSING SYSTEM MFR. & MODEL NUMBER EQUIPMENT SCHEDULE PLUMB ELECT REMARKS GAS BY G.C. SUPPLY INST. NO. NO. QTY B-242 B-252 B-265 B-275 B-295 B-300 B-305 B-310 B-400 B-405 B-406 B-410 B-643 N-062 N-071 N-075 N-130 N-134 N-171 N-207 N-903 N-909 N-912 N-922 N-923 N-926 2 1 1 1 2 2 1 1 1 1 1 4 1 X X X X X X X X X X X X X B-915 P-094 P-097 P-533 1 1 1 X X X P-803 P-XXX 1 1 X X R-011 R-067 R-100 R-400 R-905 1 1 1 1 1 ITEM DESCRIPTION MFR & MODEL NUMBER PLUMB ELECT REMARKS GAS NO. N SINKS/DISHWASHERS KAY CHEMICAL #92021176 KAY CHEMICAL #92021175 BOBRICK #B-165-1836 BOBRICK B2890 BOBRICK #B-2620 BOBRICK #B6806X36 BOBRICK #B6806X42 BOBRICK #B6806X18 RUBBERMAID #2632 (GREY) RUBBERMAID SLIM JIM #3541 (GREY) RUBBERMAID #2956 (BLACK) RUBBERMAID #6140 KAY CHEMICALS SYSTEM KIT 0187 SURFACE MTD HAND SINK MOP SINK FAUCET PRE-RINSE UNIT PREP SINK EQUIPMENT HAND SINK EQUIPMENT LEVER MOP SINK BASIN DUMP SINK PREP SINK 3-COMP LEFT HAND SINK & FAUCET W/ HANDLES LEASED DISHWASHER: ECOLAB HAND SINK SPLASH GUARDS DISH TABLE EXTENSION P FOOD PREPARATION SALAD ROLL IN MAKE TABLE 8' PIZZA MAKE TABLE GREASE SHUTTLE AERO #HSK-SKV T&S #B2465 T&S #B-0133-B T&S BRASS & BRONZE #B2463 T&S BRASS #B2460 AERO #S-20 MUSTEE #M63 AERO #2F1YUM152012 AERO #3F1-2116-18R AERO #3F3-DC-YUM-LH48 INFERNO - w/ VAPPR VENT AERO #HAND SINK SPLASH AERO #3CDL30 TRAULSEN #RPP132L-FHS-LH MCCALL X X X X X 1-COMP PROOFER 3-COMP RETARDER R REFRIGERATION UNDER COUNTER KEG COOLER W/ TAPS ICE TROUGH UNDER COUNTER MUG CHILLER UNDER COUNTER REFRIGERATOR 1-DOOR FULL HEIGHT WINGSTREET FREEZER (LH) X X X X X X X X X X X X X X X N-062 N-071 N-075 N-130 N-134 N-171 N-207 N-903 N-909 N-912 N-922 N-923 N-926 N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F C-906 C-951 C-XX1 1 1 1 X X X X X SWITCHGEAR PACKAGE C COOKING EQUIPMENT MICROWAVE FRYER PIZZA HUT OVEN, TRIPLE SURFACE MTD. SURFACE MTD SURFACE MTD SURFACE MTD SURFACE MTD VERTICALLY SURFACE MTD SEE S.O.W. FOR COMPANY VS FRANCHISE X SES #RMS10T PITCO #PHSSH552FDFSNG MIDDLEBY MARSHALL #PS870-3 X X X INCLUDES BRANCH PANELS X X INCLUDES GAS HOSE W/ START UP; (CAST IRON FINISH) C-906 C-951 C-XX1 D BUFFET - NOT USED E EXHAUST HOODS/FIRE SUPP. E-938 E-939 E-XX1 F-023 F-031 F-043 F-070 F-085 F-095 F-178 F-179 F-265 F-270 F-907 F-908 F-911 F-915 F-922 F-930 1 1 1 1 1 1 1 1 1 1 3 4 1 1 2 1 2 1 1 X X X X X X X X X X X X X X X FRYER HOOD 36" STAINLESS STEEL WALL PANEL OVEN HOOD F OFFICE/EMPLOYEE/MUSIC/MISC. MANAGER'S STOOL COAT HOOKS PH OFFICE COMPUTER PH MONITOR-OFFICE OFFICE PRINTER/ COPIER/ FAX/ SCANNER PH UPS SAFE DRIVER DROP BOX HIGH CHAIR FIRST AID KIT WALL TELEPHONE DESK TELEPHONE FILE CABINET (2 DRAWER HIGH) FLOOR MAT-CHARCOAL, 3'x5' BLACK 24x30 LICENSE FRAME WAVE TELEPHONE SYSTEM K-003 1 X K WORKSTATIONS/SHELVING/CARTS CUT TABLE K-012 K-013 K-017 K-195 K-216 1 1 1 1 1 X X X X X WINGSTREET 48" SAUCING STATION WINGSTREET PREP STATION - 24" x 30" x 74" EXPO STATION WALL GRID SYSTEM WALL MOUNTED SHELF SYSTEM CAPTIVE AIRE #3044BD2 CAPTIVE-AIRE #BSFH96X72 MIDDLEBY MARSHALL X X X SEE HOOD MFR. DRAWINGS SEE HOOD MFR. DRAWINGS SEE HOOD MFR. DRAWINGS; CAST IRON FINISH B&B SYSTEMS #4060550 BOBRICK # B-212 AMERICAN SECURITY#9336131 JR DROPBOX #DD-330 X X X X X POS PROVIDED POS PROVIDED POS PROVIDED #PRST2617 HON # HON312CPL WSM #800503 ACCUSERV #FFST E-938 E-939 E-XX1 F-023 F-031 F-043 F-070 F-085 F-095 F-178 F-179 F-265 F-270 F-907 F-908 F-911 F-915 F-922 F-930 TBD K-003 METRO #PHWF4C METRO #PHWPF TBD METRO # PHSG24 METRO #PHSS36 K-012 K-013 K-017 K-195 K-216 MOUNT TOP RAIL AT 81" SEE CUTSHEET K-830 K-870 K-879 K-886 K-893 1 3 1 1 1 X X X X X LID BIN - BLACK CART 14"x24" WIRE WALL SHELF UNIT 48" ORDER ENTRY STATION / MANAGERS DESK MAKETABLE OVERSHELF 18" x 96" W/ HOOKS & PRINTER 24" x 30" x 74" - 6 SHELF UNIT WSM #6039040 METRO # WS1424A METRO #PHMW48D METRO #PHMTS33 METRO #PH117A K-830 K-870 K-879 K-886 K-893 K-903 K-901 1 1 X X UNDERSINK SHELVING UNIT 24" x 48" x 74" 5-SHELF UNIT W/ S.S. METRO #PHUS1824 METRO # PHMW48B K-903 K-901 K-925 K-926 K-959 K-968 K-970 K-982 K-XX1 K-XX2 K-XX3 1 5 5 2 1 4 1 1 2 X X X X X X X X X 27"x 19"x 60" BAG IN BOX RACK DOUGH CART 21" x 30" 24" x 54" x 74" 5 SHELF UNIT PREP. TABLE 14"x24" DOUBLE WIRE WALL SHELF UNIT 30" x 60" x 74" - 5 SHELF 30" x 54" x 74" - 5 SHELF 24" x 30" x 74" - 5 SHELF 30" x 48" x 74" - 5 SHELF METRO #PHDC2130A METRO #PH112F METRO #PHPREP3060C METRO # PH108A METRO #PH114G METRO #PH METRO #PH METRO #PH SEE SCOPE OF WORK S-457 S-570 S-580 S-590 S-600 S-663 S-826 S-903 S-907 1 1 1 1 1 3 1 1 1 X X X X X X X X X S SERVING/PICK-UP BAG HOLDER CARBONATOR CO2 (BULK) TANK WATER FILTER SYSTEM BUNDLED SYRUP LINES 18" x 36" x 27" - UNDERCOUNTER SHELF WING HOT HOLD 7 QT. SAUCE WARMER W/ SAUCE PUMP COFFEE BREWER S-928 1 X ICE TEA BREWER S-XX2 S-XX3 S-XX4 1 1 1 X X X DRINK DISPENSER UNDER COUNTER ICE MACHINE UNDER COUNTER ICE BIN U-007 U-901 U-902 U-904 U-909 U-910 1 3 2 5 1 2 X X X X W-XX1 1 X BEVAIR #SPE4818MPH RANDELL #PH96E3MSS AERO #SSA925 X X PERLICK #DDS60 FRANKE #E4038PQ02 PERLICK #FR36SS2 BEVAIR #UCR20Y141 TRAULSEN #G12010 X X FRANKIE #27012968 CORNELIUS/REMCOR MVE #11805373 SELECTO #MF5/600 100' 12 BUNDLE METRO #PHEXPO3 PRINCE CASTLE #DHB2PT33WS2 (FUTURE ITEM) VOLLRATH #72018 SERVER PUMP #83019 BUNN # 04275.0031 X X DISHWASHER ON LEFT END CONTACT ECOLAB: SEE SCOPE OF WORK P-094 P-097 P-533 (RELOCATED FROM EXIST. STORE) (RELOCATED FROM EXIST. STORE) X REQUIRES FLOOR DRAIN X X X X X X X X P-803 P-XXX R-011 R-067 R-100 R-400 R-905 SEE SCOPE OF WORK SEE SCOPE OF WORK (PEPSI PROVIDED) WITHOUT IMPURITY RING SEE SCOPE OF WORK (PEPSI PROVIDED) SEE SCOPE OF WORK (PEPSI PROVIDED) S-457 S-570 S-580 S-590 S-600 S-663 S-826 S-903 S-907 X X X X CORNELIUS LBIT MODEL 3D X X SEE SCOPE OF WORK (LIPTON PROVIDED) S-928 TBD TBD TBD X X X X X SEE SCOPE OF WORK (PEPSI PROVIDED) SEE SCOPE OF WORK (PEPSI PROVIDED) SEE SCOPE OF WORK (PEPSI PROVIDED) S-XX2 S-XX3 S-XX4 X X X X X X SEE SCOPE OF WORK SEE SCOPE OF WORK SEE SCOPE OF WORK SEE SCOPE OF WORK SEE SCOPE OF WORK U-007 U-901 U-902 U-904 U-909 U-910 X (1) COOLER, (1) FREEZER W-XX1 U SECURITY/COMM./FIRE PROT./POS PRESENCE ALERT SYSTEM HME #C10810D FCO - FRONT CASH OUT TERMINAL, CASH DRAWER, CREDIT CARD SWIPE BOE - BACK ORDER ENTRY TERMINAL KITCHEN MONITOR ALARM SYSTEM PANEL TYCO - E53200146 SUS TICKET PRINTER W WALK-IN COOLERS/FREEZERS WALK IN COOLER / FREEZER X 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 K-925 K-926 K-968 K-968 K-970 K-982 K-XX1 K-XX2 K-XX3 CONTRACT DATE: 09.21.15 BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 L-067 L-902 1 1 X X L LIGHTING/SIGNAGE/MENUBOARDS DISCO BALL NO SMOKING SIGN ADJ #STARBURST GRAPHICS SYSTEMS, INC. L-905 L-906 L-907 L-909 L-910 L-912 1 1 2 1 1 1 X X X X X X MEN'S SIGN WOMEN'S SIGN HAND WASH SIGN DELIVERY DRIVERS ONLY SIGN NO DELIVERIES AFTER 11:00 AM SIGN HOURS SIGN GRAPHICS SYSTEMS, INC. GRAPHICS SYSTEMS, INC. GRAPHICS SYSTEMS, INC. GRAPHICS SYSTEMS, INC. GRAPHICS SYSTEMS, INC. GRAPHICS SYSTEMS, INC. X #PIZNOSMOKESUBDEL L-067 L-902 L-905 L-906 L-907 L-909 L-910 L-912 DBR 37 NOTE: L-XX2 L-XX3 L-XX4 4 4 2 X X X COUNTER MENU LUNCH MENU / PEN HOLDER EXIT SIGN VGS VGS GRAPHICS SYSTEMS, INC. L-XX2 L-XX3 L-XX1 B C E F K L P/U CLEARANCE BAR, SECURITY DOOR, WATER HEATER, P/U WINDOW, RESTROOM ACCESSORIES, AIR DOOR/CURTAIN, MOP SINK, HAND SINK ACC., CORNER GUARDS, MATS FRYERS, OVENS, GRILLS, RETHERMALIZERS, TOASTERS, MICROWAVES KITCHEN EXHAUST HOODS, FIRE SUPPRESSION EQUIPMENT SAFE, OFFICE EQUIPMENT SHELVING, WORKSTATIONS, CARTS, RACKS, DOLLIES SITE LIGHTING, SIGNAGE N P R S U W KITCHEN HAND SINKS, PREP. SINKS, DISHWASHERS HOT WATER, WORK TABLES, FOOD PREP REFRIGERATORS AND FREEZERS (NOT WALK-IN) DRINK SYSTEMS & EQUIP., HEAT CABINETS, WARMERS, SERVING EQUIP., P/U EQUIP. SECURITY SYSTEM, LOCKS, CCTV, D/T COMMUNICATIONS/POS SYSTEM, POS EQUIP. WALK-IN COOLERS/FREEZERS EQUIPMENT SCHEDULE A2.1 PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 8 6 12 11 18 2 2 15 15 1 16 15 5 17 13 3 15 15 21'-9" 15 7 14 13 12 11 19 8 6 9 10 1 15 9'-11" 9 10 18 16 14 CONTRACT DATE: 4 BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: ROOF PLAN WATERPROOFING: A. TOP NAILING AT PARAPET CAP FLASHING WILL NOT BE ACCEPTED. B. PENETRATIONS IN ROOFING MEMBRANE AND FLASHING SHALL ONLY BE MADE AS INDICATED ON THE DRAWINGS OR SPECS. SEE SPECIFICATIONS FOR SEALANT SPECS. C. ALL SHEET MTL FLASHING SHALL BE 22 GA MIN. A 1 ROOFTOP UNIT. INSTALL PLUMB AND LEVEL. 16 EXISTING PARAPET CAP TO REMAIN. 2 KITCHEN HOOD EXHAUST FAN. SEE: MECHANICAL SHEETS & 13 & 14/A7.0. 17 WATER HEATER INTAKE & EXHAUST, SEE 2/P6.0. GC TO COORDINATE LOCATION WITH PARAPET. 3 RESTROOM EXHAUST FAN. SEE: MECHANICAL SHEETS & 13 & 14/A7.0. 18 WASTE VENT THROUGH ROOF. SEE 10/A7.0 FOR FLASHING ASSEMBLY. 4 METAL CANOPY. SEE SCOPE OF WORK 19 ICE MACHINE CONDENSER ON PRESSURE TREATED BLOCKING. SEE SCOPE OF WORK. 5 REMOVE EXISTING ROOFTOP UNIT, ROOF CURB. REPAIR ROOF DECK, RIGID INSULATION AND ROOFING TO MATCH EXISTING. 6 POWER / GAS / CONDENSATE ENTRY UNDER HVAC UNIT (PER HVAC MFR. SPECS.) REFER TO MECH. AND PLUMB DWGS. UTILITY ACCESS FROM WITHIN CURB - NO ROOF PENETRATIONS. DO NOT RUN ON ROOF SURFACE. 7 WALK-IN COOLER / FREEZER CONDENSERS ON PRESSURE TREATED BLOCKING. SEE SCOPE OF WORK SHEET. MISCELLANEOUS: A. ROOF PENETRATIONS CLOSER THAN 12" FROM ANOTHER WILL NOT BE ALLOWED. B. EXHAUST FANS MIN. 10'-0" AWAY FROM ALL AIR INTAKE / SUPPLY. 1/4"=1'-0" 09.21.15 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 ROOF INSULATION: A. RIGID BOARD, INSULATION TYPE 3. REFER TO SPECIFICATION SECTION 07210. B. BOARD THICKNESS TO BE DETERMINED BY SITE-SPECIFIC REGIONAL REQUIREMENTS; 1/4" MINIMUM (PER ROOFING SYSTEM STANDARD). DBR 37 8 OUTSIDE AIR INTAKE FOR ROOFTOP UNIT. MAINTAIN MIN 10'-0" SEPARATION FROM PLUMBING VENTS, FLUES AND BUILDING EXHAUST. ROOFING SYSTEM: 9 A. DURO-LAST SINGLE-PLY SYSTEM. REFER TO SPECIFICATIONS SECTION 07523. B. G.C. SHALL COORDINATE ALL INSTALLATION REQUIREMENTS. 10 PIPE HOOD FOR CONDENSER LINES. SEE DETAIL 9/A7.0. ROOF PLAN DOWNSPOUT AND GUTTER. 11 ROOF CRICKETS: MAINTAIN MFR'S ROOFTOP UNIT MAINT CLEARANCE. A. CRICKETS @ ROOFTOP EQUIPMENT SHALL BE FORMED WITH TAPERED INSULATION TO SUCH AN EXTENT AS TO PROVIDE A POSITIVE MIN. 1/2" SLOPE TO THE VALLEY. 12 HVAC ROOF CURB. SEE DETAIL 16/A7.0. 13 A3.0 EXISTING ROOFING TO REMAIN. 14 SEE SCOPE OF WORK FOR WALL SIGNAGE, TYP. 15 ROOF CRICKET. NOT USED C ROOF PLAN NOTES C KEY NOTES B PLOT DATE: 13 12 N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 3 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 11 2 1 5 4 6 16 15 14 5 4 17 6 2 11 10 14 14 11 9 18 10 LEFT SIDE ELEVATION 1/4"=1'-0" A 12 11 3 4 5 13 4 5 15 1 11 15 5 6 2 17 2 6 2 8 4 4 7 1 11 FRONT ELEVATION 1/4"=1'-0" C FRONT ELEVATION QTY. NOTE SIGNAGE VENDOR TO PROVIDE TRANSFORMERS TO GC PRIOR TO INTERIOR DRYWALLING. GC TO INSTALL TRANSFORMERS 12" MINIMUM ABOVE TRUSS BEARING LINE AND STUB OUT ELECTRICAL PER LOCATIONS SHOWN. ROUTE ALL CONDUIT IN THE EXTERIOR WALL. ITEM 1/4"=1'-0" B ELEC 1 2 DBR 40" PIZZA HUT SIGN X 2 2 DBR 72" DIAM. SWIRL SIGN X 5 1 DBR 18" CANOPY X 6 MISC DBR METAL BEAM X 7 MISC DBR CORNER LED X CONTRACT DATE: NO CONDUIT IS TO PENETRATE THE ROOF. 09.21.15 BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 SIGNAGE DETAIL SYMBOL PRODUCT NTS MANUFACTURER J NOT USED COLOR ALTERNATE MFR. PAINT SHERWIN WILLIAMS MACADAMIA #SW6142 - - 2 PAINT SHERWIN WILLIAMS TRICON BLACK #SW6528 - - STANDING SEAM 5 METAL H REMARKS 1 4 NTS NOT USED NTS E MISCELLANEOUS A. SEE SHT A1.1 "WINDOW TYPES" FOR WINDOW ELEVATIONS. B. SEE SCOPE OF WORK FOR RESPONSIBILITIES. AEP SPAN COOL RED 16" STRAITED - - SEALERS (REFER TO SPECS): A. SEALANT AT ALL WALL AND ROOF PENETRATIONS. B. SEALANT AT ALL WINDOW AND DOOR FRAMES AT HEAD AND JAMB. DO NOT SEAL SILL @ WINDOWS. SHERWIN WILLIAMS TRICON BLACK #SW6528 - - LEGEND: A. VENDOR SCOPE INCLUDES SUPPLY AND INSTALLATION OF AWNINGS, CANOPIES, AND SIGNAGE. EXTERIOR FINISH SCHEDULE G GENERAL NOTES F SIGNAGE & AWNING SCHEDULE D NOT USED NTS 1 NOT USED. 14 L.E.D. LIGHTING. SEE ELECTRICAL 2 EXISTING E.I.F.S. TO REMAIN. PATCH AND REPAIR AS REQUIRED. SKIMCOAT WHERE SIGNS ARE REMOVED. 15 METAL AWNING, SEE SCOPE OF WORK 16 3 EXISTING METAL ROOF TO REMAIN. PRE-FINISHED METAL WALL PANELS - REF. SPECS. 17 4 EXISTING GUTTER AND DOWNSPOUT TO REMAIN. EMERGENCY LIGHTING, RE: ELECTRICAL 5 EXISTING BUILDING LIGHTING TO REMAIN. 6 NOT USED. 7 EXISTING HM DOOR AND FRAME. PAINT. 8 REWORK EXISTING ALUMINUM STOREFRONT SEE SHEET A1.1. 9 EXISTING HOSE BIBB TO REMAIN. 10 NEW ALUMINUM STOREFRONT DOOR AND WINDOW 11 EXISTING SPLIT FACED CMU TO REMAIN. 12 INDICATES ROOF OR PARAPET BEYOND 13 SIGNAGE, RE: DETAIL J/A4.0 AND SCOPE OF WORK D DBR 37 EXTERIOR ELEVATIONS A4.0 KEY NOTES C PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 NOT USED NTS 18 NOT USED STANDARD CURB BASE, FASTEN PER MFR'S RECOMMENDATIONS PREFABRICATED CUSTOM CURB FLASHING 14 SCHEDULE ROOF DECK and ROOF OPENING SUPPORT 2x SOLID BLOCKING STACKED W/ DRILLED HOLE FOR PIPE PENETRATION 8" MIN. HINGED BASE FOR SERVICING/ CLEANING. SEAL WITH APPROVED MATERIAL 40" MIN. KNOCK-DOWN FLAT METAL CURB SEE SCOPE OF WORK 5/8" PLYWOOD SECURED TO CURB - 4 2X4 WOOD STUDS AT 16" O.C. GROUT CORES SOLID SEALANT @ PENETRATION SEALED PIPE FLASHING KITCHEN HOOD EXHAUST FAN 1" HEAD NAILS AT 6" O.C. 8" MIN. T.O. CURB TO T.O. ROOF FILL AREA AROUND PIPING W/ FOAM INSULATION TO SEAL SPACES 1 1/2"=1'-0" 10 NOT USED N.T.S. 6 STANDING SEAM METAL SIDING NEW BEAM SEE STRUCTURAL DRAWINGS MULTI PIPE GROUPING PIPE SLOPING DOWN AWAY FROM SHROUD MIN. 24 GA. G.I. PIPE ENCLOSURE COVER PRE-FABRICATED VENTILATED CURB EXTENSION NEMA 3R FUSED DISCONNECT, MOUNT TO HINGED BASE, SEE ELEC. 1" HEAD NAIL @ 6" O.C. SHEET METAL COUNTER FLASHINGWRAPS TOP & OUTSIDE OF CURB, EXTENDING OVER BASE FLASHING SCREW THRU NEOPRENE WASHER , 3 PER SIDE PREFABRICATED GALV. STEEL CURB W/ INSULATION (2) 2x12 WD CURB OVER 2x SECURED TO DECK CURB FLASHING TAPERED SLEEPER TO LEVEL CURB ROOFING MATERIAL OVER RIGID INSULATION NOTE: EXHAUST FAN SHALL BE LEVEL WITHIN 1/8" OVER WIDTH OF CURB NOTE: RTU SHALL BE LEVEL WITHIN 1/8" OVER LENGTH OF EQUIPMENT SCHEDULE ROOF DECK and ROOF OPENING SUPPORT SCHEDULE ROOF DECK and ROOF OPENING SUPPORT HVAC CURB 3"=1'-0" 16 BASE FLASHING DUCT WRAP - SEE MECHANICAL N.T.S. ANODIZED ALUMINUM WINDOW FRAME - SEE WINDOW SCHEDULE. ALIGN FRAME WITH FACE OF PLYWOOD SHEATHING. SCHEDULE ROOF DECK and ROOF OPENING SUPPORT MIN. 16 GA. WELDED DUCT EXHAUST FAN CURB WRAP LEDGER BOARDS IN BREAK METAL BY AWNING CONTR. 2X HEADER WITH 1/2" PLYWOOD - SEE STRUCTURAL CONTRACT DATE: WRAP GYP. BD. TO FRAME SEALANT AND BACKER ROD 13 MULTIPLE PIPE FLASHING 1-1/2" = 1'-0" 9 NOT USED 3"=1'-0" 6 ENTRY AWNING / TRANSOM HEAD DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 3"=1'-0" 2 09.21.15 BUILDING TYPE: 311465 / 434385 STORE NUMBER: 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 ALUM STOREFRONT ENTRY SYSTEM ALUMINUM STOREFRONT SYSETM DOOR SILL. REF: DOOR SCHEDULE EXPANSION JOINT DBR 37 METAL FLASHING WITH WEEP HOLES 1/2" MAX 1'-2" NOTE: EXHAUST FAN SHALL BE LEVEL WITHIN 1/8" OVER WIDTH OF CURB 1-1/2" = 1'-0" NOT USED NEW SPLIT FACED CMU TO MATCH EXISTING ROOFING MATERIAL EXHAUST FAN CURB UNIT COUNTERFLASHING W/ NEOPRENE PERIMETER GASKET 7 DURO-LAST ROOFING MATERIAL OVER RIGID INSULATION (2) TAPERED 2x12 WD CURB OVER 2x SECURED TO DECK SCHEDULE ROOF DECK and ROOF OPENING SUPPORT HVAC UNIT 6" = 1'-0" DURO-LAST PRE-FABRICATED VENT STACK FLASHING 8" MIN. SCREW THRU NEOPRENE WASHER , 3 PER SIDE 17 NOT USED S.S. BAND POSITIONED 1/4" FROM TOP OF STACK FLASHING GALVANIZED NAILS @ 6" O.C. 3" = 1'-0" 11 TYPICAL VENT PIPE ELECTRICAL CONDUIT NOT USED 1-1/2"=1'-0" EXTERIOR CONSTRUCTION DETAILS CONC SIDEWALK CONC SIDEWALK EXPANSION JOINT NOT USED 1-1/2"=1'-0" 15 NOT USED N.T.S. 11 NOT USED 3" = 1'-0" 8 DOOR SILL 3"=1'-0" 5 A7.0 STOREFRONT SILL DETAIL 3"=1'-0" 1 PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 B-1 B-1 B-1 T-1 T-1 T-1 TYP. @ ALL KITCHEN AREAS TYP. @ ALL KITCHEN AREAS TYP. @ ALL KITCHEN AREAS 10 11 10 10 9 5 10 3 6 11 5 2 F-1 T-1 B-2 6 F-1 F-1 7 B-3 B-3 F-1 B-3 1 F-1 6 F-1 B-2 B-2 7 7 CONTRACT DATE: BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: FLOOR FINISH PLAN 1/4"=1'-0" A. SEE SPECS FOR PAINTING, GYPSUM BOARD AND TILE. 1 FACTORY FLOOR FINISH (GALV STL) W/ INTEGRAL COVE BASE AND BUILT-IN INT. RAMP. B. 2 CONTRACTOR SHALL PROVIDE FLOOR TILE INSIDE WALK-IN COOLER, BASE TILE PROVIDED WITH COOLER. FLOAT FLOOR TILE IN COOLERS TO DRAIN TO KITCHEN. COORD. WITH COOLER WALL CONFIGURATION 3 5/8" CEMENT BOARD PLATFORM AT SAFE LOCATION. SEE DETAIL 13/A11.0. 4 NOT USED. 5 FLOOR SINK - REF. P2.0 6 FLOOR DRAIN - REF. P2.0 7 SANITARY TILE BASE IN RESTROOMS. SEE DETAIL 6/A11.0 FOR INSTALLATION. 8 NOT USED. 9 MOP SINK LOCATION F-# DENOTES FINISH MATERIAL. REFER TO SHT A8.1 FOR FINISHES. B-# C. TILE JOINTS (U.O.N.): 1. FLOOR TILE 2. FLOOR FINISH TILE 3. BASE, TRIM AND ACCESSORIES: MATCH ADJOINING TILE UNITS D. FLOOR TILE JOINTS SHALL MATCH UP WITH SLAB JOINTS. E. ALL BASE TILE SHALL BE SANITARY COVE STYLE WITH 3/8" MIN RADIUS. F. SEE SCOPE OF WORK SHEETS FOR RESPONSIBILITIES. G. PROVIDE CLEAR SILICONE CAULK WHERE FRP STOPS AT TOP OF COVE BASE. H. PROVIDE CLEAR SILICONE CAULK WHERE ALL FIXED AND BUILT-IN COUNTERS / EQUIPMENT ABUTS WALL SURFACE. I. ALL INTERIOR FINISHES SHALL HAVE CLASS 1 FIRE RATING. 10 LINE OF FLOOR FINISH TRANSITION 11 8" DIA. PVC STUB DOWN BELOW SLAB. A 09.21.15 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 DBR 37 FLOOR FINISH PLAN A8.0 NOT USED D FINISH NOTES C KEY NOTES B PLOT DATE: FLOORS SYM WALLS DESCRIPTION ALTERNATE/NOTES SYM LAMINATES / MISC DESCRIPTION ALTERNATE/NOTES SYM DESCRIPTION CEILINGS ALTERNATE/NOTES DESCRIPTION SYM NOTES N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F F-1 MFR: TYPE: NAME: COLOR #: SIZE: GROUT: SEALER: T-1 T-2 MFR.: TYPE: COLOR: SIZE: GROUT: SEALER: MFG: TYPE: NAME: COLOR #: FIANDRE USA PORCELAIN TILE SHELLSTONE SHELLSTONE 12" x 24" OR 18" x 36" POLYBLEND GROUT #185 NEW TAUPE AQUA MIX SEALER'S CHOICE (SEAL GROUT ONLY). ALTERNATE SEALER: MIRACLE SEALANTS 511 IMPREGNATOR. ITEM: MFG.: COLOR: COLOR #: POLISHED CONCRETE, MEDIUM GRADE (MG-2) FRP-1 ITEM: FRP L & M CONSTRUCTION CHEMICALS MFG.: MAR-LITE VIVID DYE PRODUCT #: P-100 COCOA BROWN 100% NAME: FRP POLYBLEND #52 TOBACCO BROWN GROUT @ SAW CUTS SEALER: AQUA MIX SEALER'S CHOICE (SEAL GROUT W-1 MFR: GLEN GARY ONLY). ALTERNATE SEALER: MIRACLE SEALANTS TYPE: THIN BRICK 1/2" COLOR: MILWAUKEE, RUNNING BOND PATTERN 511 IMPREGNATOR. SIZE: 1/2" x 2 1/4" x 7 5/8" MORTAR: NATURAL GREY PIPED, ROUGH RAKED LOCATION: DINING ROOM & RESTROOMS CROSSVILLE PORCELAIN TILE GREY MINGLE CROSS TREAD 8" x 8" POLYBLEND GROUT #335 WINTER GREY AQUA MIX SEALER'S CHOICE (SEAL GROUT ONLY). ALTERNATE SEALER: MIRACLE SEALANTS 511 IMPREGNATOR. LOCATION: B.O.H. & SERVICE LINE FLOORING RESILIENT FLOORING - VCT ARMSTRONG EXCELON IMPERIAL TEXTURE CLASSIC BLACK #51910 LOCATION: BOOTH RAISED PLATFORM FLOORING WALL BASE SYM B-1 B-2 B-3 DESCRIPTION MFR.: TYPE: COLOR: SIZE: GROUT: SEALER: LOCATION: B.O.H. & SERVICE LINE MFG: ITEM: NAME: COLOR: SIZE: GROUT: COVE TRIM: DALTILE PORCELAIN TILE ALTA VISTA SUNSET GOLD #AV51 6" X 12" POLYBLEND GROUT #380 HAYSTACK SCHLUTER #DILEX-AHKA (BRUSHED STEEL) LOCATION: RESTROOMS MFR.: TYPE: COLOR: SIZE: ARMSTONG VINYL COVE BASE JET BLACK 4" LOCATION: BASE AT WOOD WAINSCOT & RAISED BOOTH PLATFORM M-1 USE THIN TECH - CLASSIC SERIES M-2 LOCATION: F.O.H. WALLS W-2 MFR: NAME: SIZE: GROUT: USE BRUSHED STEEL VERTICAL TRANSITION AT IRIS CERAMICS US MAIOLICA ROSSO OUTER CORNERS: SCHLUTER - QUADEC-EB 4" x 12", HORIZONTALLY LAID RUNNING BOND POLYBLEND GROUT #60 CHARCOAL LOCATION: FEATURE COOK LINE VERTICAL WALL W-3 MFR: TYPE: NAME: COLOR: SIZE: GROUT: DALTILE PORCELAIN TILE ALTA VISTA SUNSET GOLD AV51 12" x 12" POLYBLEND GROUT #380 HAYSTACK LOCATION: RESTROOM WALLS ST-1 MFR: TYPE: SPECIES: STAIN: ITEM: MFG: COLOR: REMARKS: MINWAX OIL BASED WOOD STAIN BIRCH PLYWOOD GOLDEN OAK #210B CLEAR COAT LACQUER OIL BASED WOOD STAIN #T77F62 MEDIUM RUBBED EFFECT LOCATION: RESTROOM HALLWAY WAINSCOT P-1 ITEM: MFG.: TYPE: COLOR: TEXTURE: PAINT SHERWIN WILLIAMS SEMI-GLOSS ENAMEL MACADAMIA #SW6142 LIGHT ORANGE PEEL LOCATION: LOWER BULKHEAD FACE (TV WALL), RESTROOM HALL & UPPER RESTROOM WALLS P-2 ITEM: MFG.: TYPE: COLOR: TEXTURE: PAINT SHERWIN WILLIAMS SEMI-GLOSS ENAMEL FOOTHILLS #SW7514 LIGHT ORANGE PEEL LOCATION: UPPER BULKHEAD FACE P-3 ITEM: MFG.: TYPE: COLOR: TEXTURE: PAINT SHERWIN WILLIAMS SEMI-GLOSS ENAMEL SUNDEW #SW7688 LIGHT ORANGE PEEL LOCATION: BULKHEAD SOFFIT P-4 ITEM: MFG.: TYPE: COLOR: TEXTURE: PAINT SHERWIN WILLIAMS FLAT ENAMEL TRICORN BLACK #SW6258 LIGHT ORANGE PEEL LOCATION: DINING ROOM BLADE ELEMENT P-5 ITEM: MFG.: TYPE: COLOR: TEXTURE: PAINT SHERWIN WILLIAMS FLAT ENAMEL BLACK FOX #SW7020 LIGHT ORANGE PEEL LOCATION: MISC CEILING FIXTURES AT AND ABOVE BOTTOM OF TRUSSES IN DINING SPACE ALTERNATE/NOTES CROSSVILLE PORCELAIN STONE GREY MINGLE 6"x8" COVE BASE POLYBLEND GROUT #335 WINTER GREY AQUA MIX SEALER'S CHOICE (SEAL GROUT ONLY). ALTERNATE SEALER: MIRACLE SEALANTS 511 IMPREGNATOR. LOCATION: B.O.H. WALLS MFR: ITEM: COLOR: WILSONART PLASTIC LAMINATE MOUNTAIN PASSAGE #1843K-45 LOCATION: MILLWORK INSETS MFR: ITEM: COLOR: THICKNESS: WILSONART SOLID SURFACE NIGHT STARS #9105CS(5) 1/2" MIN THICKNESS LOCATION: ALL COUNTERTOPS CL-1 CL-2 CL-3 ITEM: MFG.: COLOR: LOCATION: PAINTED STRUCTURE SHERWIN WILLIAMS BLACK FOX #SW7020 DINING ROOM EXPOSED ROOF TRUSS AND 1" TECTUM SOUND ABSORPTION BOARD APPLIED TO THE BOTTOM OF ROOF DECK, BETWEEN TRUSSES, PAINT TO MATCH TRUSSES. INCLUDING DUCT, CONDUIT, HANGERS, AND SIMILAR EXPOSED ITEMS. ITEM: MFG.: TYPE: COLOR: PAINTED GYPSUM BOARD CEILING SHERWIN WILLIAMS SEMI-GLOSS ENAMEL TOWNHALL TAN #SW7690 SMOOTH - NO TEXTURE ITEM: MFG.: TYPE: SIZE CEILING TILE & GRID GYPSUM LAY IN PANEL WHITE VINYL WITH STIPPLE PATTERN 1/2" x 24" x 24" LOCATION: RESTROOM HALLWAY ACOUSTICAL CEILING GRID SHALL BE EQUAL TO ARMSTRONG PRELUDE 15/16" OR US GYPSUM ENVIRONMENTAL ZXA GRID SYSTEM. WIDE FACED, ALUMINUM CAPPED, DOUBLE WEB, HOT DIP GALVANIZED STEEL, INTERMEDIATE DUTY, HIGH HUMIDITY FINISH, PAINTED WHITE. ALTERNATE: MFR: ARMSTRONG TYPE: #793 GEORGIAN HIGH WASHABILITY COLOR: WHITE SIZE: 1/2" x 24" x 24" LOCATION: KITCHEN AND RESTROOM CEILING CONTRACT DATE: DOORS/TRIM SYM ST-1 1. INSTALL FRP PANELS ON WALLS FROM TOP OF TILE BASE TO BOTTOM OF CEILING GRID EXCEPT WHERE CERAMIC TILE IS INDICATED. INSTALL FRP ON KITCHEN SIDE OF SERVING COUNTER WALL. 2. GALV STEEL WALL AND CEILING FINISHES BY WIC / WIF BOX MFR. 3. REFER TO INTERIOR ELEVATIONS FOR LOCATIONS OF TILE AND FRP. 4. FOR FINISH LOCATIONS REFER TO: SHEETS A4.0 & A4.1 - EXTERIOR ELEVATIONS SHEET A8.0 - FLOOR FINISH PLAN SHEET A9.0 - REFLECTED CEILING PLAN SHEETS A10.0 TO A10.4 - INTERIOR ELEVATIONS 5. MARLITE CUSTOMER SERVICE 800-377-1221 www.marlite.com ARMSTRONG STEVE PATTERSON 214-755-9186 BLIND EXPRESS, INC. LEE ASKENAS 30 Mansell Court, Suite 108 Roswell, GA 30076 P: 770-664-1688 F: 770-664-1191 [email protected] ALL INTERIOR FINISHES SHALL HAVE CLASS 1 FIRE RATING. WILSONART INTERNATIONAL, INC. TERESA HUMPHRY 214-634-2310 [email protected] ECO-LAB NATE DAMRO 3309 MATRIX DRIVE phone: 651-293-4205 ALTERNATE/NOTES ALL TRIM IS 1X4 UNLESS NOTED OTHERWISE - 1X2 TRIM BETWEEN PLYWOOD JOINTS MFR: TYPE: SPECIES: STAIN: ITEM: MFG: COLOR: REMARKS: MINWAX OIL BASED WOOD STAIN RED OAK GOLDEN OAK #210B CLEAR COAT LACQUER OIL BASED WOOD STAIN #T77F62 MEDIUM RUBBED EFFECT P-6 ITEM: MFG.: TYPE: COLOR: PAINT SHERWIN WILLIAMS SEMI-GLOSS ENAMEL BLACK FOX #SW7020 LOCATION: DINING & RESTROOM DOORS & FRAMES P-7 ITEM: MFG.: TYPE: COLOR: PAINT SHERWIN WILLIAMS SEMI-GLOSS ENAMEL GREY CLOUDS #SW7658 LOCATION: B.O.H. EXIT DOORS & FRAMES IRIS CERAMICS US NOREEN SCHERTLER 312-342-4689 GLEN GERY BRICK MIKE SCHMEDDING 816-589-3956 DESCRIPTION LOCATION: WAINSCOT / CHAIR RAIL & MISC TRIM IN DINING / RESTROOM HALL ROOM FINISH NOTES D 09.21.15 BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 DBR 37 CROSSVILLE TONI HALE 931-456-3997 DALTILE SHANNON HOPKINS 214-392-3000 [email protected] 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 FINISH SCHEDULES NOTE: CONTRACTOR SHALL REQUEST "PIZZA HUT NATIONAL PRICING" WHEN ORDERING MATERIALS NATIONAL ACCOUNT PRICING-CONTACTS A8.1 C ROOM FINISH SCHEDULE LEGEND A PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 1'-2" 1'-821" 1 DRY STORAGE CL-3 10'-2" 15 DELIVERY SERVICE 7 CL-3 10'-2" 4 7 CL-3 10'-2" 18 TYP. 7 7'-0" CL-3 10'-2" 4'-6" TYP. 4 4'-6" TYP. CL-2 9'-6" EQ. DISHWASH EQ. 13 2 TYP. 2 TYP. EQ. 18 TYP. 13 4 10 8'-6" CL-3 COOLER 11 18 TYP. 4 6'-421" 6'-0" 17 10'-0" 6'-0" 17'-2" 17 MEN 11 19 19 19 19 FREEZER 10 DINING 4 CL-1 8'-6" CL-3 8'-6" CL-3 WOMEN 11 11 8 TYP. VESTIBULE 6'-4" 6'-4" 6'-4" 6'-4" 11 4 3" 14'-74 11 2'-021" 4 6'-4" 6'-321" 4 7'-7" 6 18 TYP. 3 CONTRACT DATE: 5 BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: REFLECTED CEILING PLAN 1 CEILING GRID STARTING POINT. 16 NOT USED. 2 CENTER DOWNLIGHT IN CEILING TILE THROUGHOUT SERVING/BAR. (U.N.O.) 17 MECHANICAL DUCTWORK. PAINT TO MATCH CEILING. 3 RECESSED LED IN SOFFIT BY AWNING CONTRACTOR. SEE SCOPE OF WORK. 18 RECESSED DOWN LIGHT.(TYP.) SUSPENDED CEILING: A. ACOUSTICAL PANEL INSTALLATION: INSTALL ACOUSTICAL PANELS WITH EDGES IN CLOSE CONTACT WITH METAL SUPPORTS AND IN TRUE ALIGNMENT. B. ALLOWABLE VARIATIONS FROM FLAT AND LEVEL SURFACE: 1/8" IN 10'-0" MAX. C. ALLOWABLE VARIATIONS FROM PLUMB OF GRID MEMBERS: AS CAUSED BY ECCENTRIC 4 EXTEND WALL TO BOTTOM ROOF DECK. 19 TRACK MOUNTED ON BOTTOM OF JOIST @ 11'-1 1/2" A.F.F. 4'-0" AND 8'-0" LENGTHS AS NOTED. 5 METAL CANOPY WITH LED LIGHTING. SEE SCOPE OF WORK. 6 DISCO BALL STARBURST LIGHT BY AMERICAN DJ SUPPLY. D. INSTALL SYSTEM AFTER MAJOR ABOVE CLG. WORK IS COMPLETE. COORD LOCATIONS OF HANGERS WITH RELATED WORK. E. SEE SPECS FOR ADDITIONAL INFORMATION. 7 PROVIDE BLOCKING ALONG ENTIRE LENGTH OF BULKHEAD BEHIND SUBSTRATE FOR SHELVING TO BE MOUNTED ALONG BACKSIDE OF BULKHEAD. 8 PENDANT LTG - CENTER OVER TABLE TOP (TYP) SEE DWG A2.0 FOR TABLE LOCATIONS. 9 NOT USED. 10 WALK-IN LIGHTING SUPPLIED BY WALK-IN MFR. 11 EMERGENCY DUAL HEAD FIXTURE. BATTERY UNIT INSIDE ABOVE CLG. SEE ELECT. DWGS. 12 NOT USED. 13 GYPSUM BOARD BULKHEAD. 14 NOT USED 15 REFER TO SHEETS M3.0, M3.1 AND M3.2 FOR EXHAUST HOOD INFORMATION. DIMENSIONS: A. ALL DIMENSIONS ARE TO FACE OF FINISH U.O.N. 1" TECTUM SOUND BOARD @ ALL EXPOSED CEILINGS (CL-1) 2'-0" x 4'-0" FLUORESCENT LIGHT FIXTURE S S 2'-0" x 2'-0" FLUORESCENT LIGHT FIXTURE EXTERIOR WALL FIXTURE WIRE GUARD FIXTURE HORIZONTAL MTD. OUTSIDE SPEAKER SMALL PENDANT SPEAKER P.O.S. MONITOR C.C.T.V. CAMERA DOWNLIGHT @ WALK-IN (BY WALK-IN MFR.) PENDANT FIXTURE CEILING FINISHES: A. REFER TO ROOM FINISH SCHEDULE (SHT A8.1) FOR CLG. FINISHES. EXTERIOR EMERGENCY LIGHTS INTERIOR HIGH OUTPUT L.E.D. (RED) C.C.T.V. MONITOR 12" EXHAUST FAN GYPSUM BOARD CEILING: A. SUBSTRATE SHALL BE 5/8" THICK TYPE "X" GYP BD. B. ACOUSTICAL SEALANT: APPLY TO GYP. BD. PANELS AS INDICATED IN SPECS. GYP. BD. FINISHING AND DECORATING: REFER TO DWGS FOR TEXTURE AND FINISHES. C. PAINT GRILLES & DIFFUSERS TO MATCH CEILING COLOR. HVAC RETURN GRILLE ELECTRICAL: A. SEE ELECT. DWGS. FOR FIXTURE SCHED. DOWNLIGHT EMERGENCY LIGHTS EXIT LIGHT (WALL MOUNTED) GENERAL NOTES F EXIT LIGHT (CEILING MOUNTED) HVAC SUPPLY DIFFUSER FIXTURE, TRACK MOUNTED PENDANT OR DIRECTIONAL STROBE LIGHT BACK DOOR SECURITY CEILING SYMBOL LEGEND E REFLECTED CEILING PLAN NOTES D 1/4"=1'-0" A 09.21.15 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 DBR 37 REFLECTED CEILING PLAN A9.0 KEY NOTES B PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 P-5 1'-021" P-5 W-1 15 TV P-1 1 A11.0 7'-0" ST-1 10'-1" P-1 OPEN TO VESTIBULE BEYOND M-1 2 A11.0 M-1 2'-10" 4'-0" M-2 B-3 B-3 B-3 DINING ROOM 3/8"=1'-0" ST-1 3 DINING ROOM P-5 3/8"=1'-0" 2 DINING ROOM P-1 P-3 UNDER SIDE OF SOFFIT P-2 27 27 27 27 27 27 TV TV TV TV TV TV 1'-021" P-2 AND CLIPS WITH 3/8" TEMPERED GLASS SNEEZE GUARD (TYP.) U-901 U-901 M-2 3'-6" 2'-10" 3'-6" 6'-0" 2'-10" 4'-10" OPENING FOR GLASS REACH-IN COOLER U-901 P-3 UNDER SIDE OF SOFFIT 7'-0" P-5 2'-10" 2'-6" 1'-721" P-1 CARRYOUT MONITOR P-2 1 P-5 P-5 P-3 UNDER SIDE OF SOFFIT 3/8"=1'-0" CONTRACT DATE: BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: M-1 09.21.15 311465 / 434385 STORE NUMBER: B-3 M-1 M-2 B-3 M-1 M-2 M-1 B-3 M-2 M-2 M-1 B-3 PIZZA HUT B-3 M-1 DINING ROOM 3/8"=1'-0" 2015388.14 4 123 Minden Shopping Dr. Minden, LA 71055 1. PROVIDE PROPER 2x BLOCKING AT WALL RECESSED MOUNTED ACCESSORIES. 2. GRAB BARS, FASTENERS AND MOUNTING DEVICES SHALL BE INSTALLED PER ADA REQUIREMENTS. REFER TO SHEET ADA1.0. 3. REFER TO FLOOR PLAN NOTES FOR BLOCKING AND SUBSTRATE NOTES. 4. LOCATE FLUSH HANDLE ON WIDE SIDE OF STALL. 5. PROVIDE WALL TILE BEHIND ENTIRE MIRROR AREA TO ALIGN MOUNTING SURFACES. DBR 37 INTERIOR ELEVATIONS DINING 6. REFER TO SHEET ADA1.0 FOR MOUNTING HEIGHTS AND CLEARANCES OF ACCESSORIES AND FIXTURES. 7. ALL DIMENSIONS THIS DRAWING ARE TO FINISH SURFACE. A10.0 GENERAL NOTES A PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 ST-1 ST-1 ST-1 ST-1 B-3 B-3 4'-0" M-1 B-3 B-3 SEE SHEET A8.1 FOR FINISH SCHEDULE. 3/8"=1'-0" 4 DINING 3/8"=1'-0" 3 DINING 3/8"=1'-0" 2 DINING 3/8"=1'-0" 1 P-3 UNDER SIDE OF SOFFIT U-901 U-901 OPEN TO DINING BEYOND U-901 OPEN TO DINING BEYOND B-292 B-252 B-242 N-062 K-970 N-903 M-2 M2 F-173 B-1 FRP-1 3'-6" DINING 2'-10" A 2'-10" GENERAL NOTES 10'-2" X-X M-1 2'-10" M-1 4'-0" 2'-10" M-1 4'-0" M-2 4'-0" M-2 FRP-1 R-011 R-XX3 B-405 B-1 SERVICE 3/8"=1'-0" 5 CONTRACT DATE: 09.21.15 BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 DBR 37 INTERIOR ELEVATIONS SERVICE A10.1 PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F LIGHT RE: ELEC. 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 LIGHT RE: ELEC. P-1 P-1 7'-6" P-1 P-6 P-6 7'-6" P-6 6'-6" P-1 9" P-6 P-6 9" 8'-6" 8'-6" 8'-6" OPEN TO DINING ROOM B-2 WOMEN B-3 5 3/8"=1'-0" WOMEN 3/8"=1'-0" 4 ST-1 3'-1021" 5'-0" 3'-1021" ST-1 3'-1021" ST-1 5'-0" ST-1 P-6 ST-1 ST-1 B-3 VESTIBULE 3/8"=1'-0" B-3 3 VESTIBULE 3/8"=1'-0" 2 VESTIBULE 6'-6" 3/8"=1'-0" 1 LIGHT RE: ELEC. LIGHT RE: ELEC. P-1 B-3 P-6 7'-6" 6'-6" 6'-6" P-1 7'-6" 6'-6" 6'-6" MEN 3/8"=1'-0" 11 MEN 2'-10" 2'-10" 8'-6" W-3 3/8"=1'-0" 10 MEN 3/8"=1'-0" 9 MEN 3/8"=1'-0" 8 WOMEN 3/8"=1'-0" 7 WOMEN 3/8"=1'-0" 6 12'-821" CONTRACT DATE: 1'-5" HOLD 6'-3" 9 PLAN VERSION: 009.00.00 5 WOMEN SEE SHEET A2.0 FOR EQUIPMENT KEYNOTES 7'-521" 2 A10.2 1 2'-0" CLEAR 3 4 4'-8" CLEAR 123 Minden Shopping Dr. Minden, LA 71055 1. PROVIDE PROPER 2x BLOCKING AT WALL RECESSED MOUNTED ACCESSORIES. 5'-0" CLEAR 1'-6" CLEAR 6 A10.2 2015388.14 5'-0" CLEAR 1'-6" CLEAR 7 311465 / 434385 PIZZA HUT 2'-0" CLEAR 2'-6" CLEAR 1'-3" MIN. 4'-0" CLEAR MEN SEE SHEET A2.0 FOR EQUIPMENT KEYNOTES 4'-0" CLEAR A10.2 2'-6" CLEAR 4'-8" 8 CLEAR 5'-0" CLEAR DBR 37 STORE NUMBER: 4'-0" CLEAR 5'-041" 5'-0" MIN 11 7'-6" BUILDING TYPE: SITE NUMBER: 10 09.21.15 2. GRAB BARS, FASTENERS AND MOUNTING DEVICES SHALL BE INSTALLED PER ADA REQUIREMENTS. REFER TO SHEET ADA1.0. DBR 37 3. REFER TO FLOOR PLAN NOTES FOR BLOCKING AND SUBSTRATE NOTES. 4. LOCATE FLUSH HANDLE ON WIDE SIDE OF STALL. 5. PROVIDE WALL TILE BEHIND ENTIRE MIRROR AREA TO ALIGN MOUNTING SURFACES. 4'-0" CLEAR 6. REFER TO SHEET ADA1.0 FOR MOUNTING HEIGHTS AND CLEARANCES OF ACCESSORIES AND FIXTURES. 7. ALL DIMENSIONS THIS DRAWING ARE TO FINISH SURFACE. 4'-1041" ENLARGED RESTROOM FLOOR PLAN X-X 3/8"=1'-0" 12 INTERIOR ELEVATIONS RESTROOMS A10.2 SEE SHEET A8.1 FOR FINISH SCHEDULE. GENERAL NOTES A PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 CONTRACT DATE: 09.21.15 BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 DBR 37 METRO SHELVING ASSEMBLY AIDS A10.3 PLOT DATE: ALUM. BRAKE METAL FINISH TO MATCH ALUM. STOREFRONT 1/2" PLYWD. ON 1x WOOD BLKG. 2" 2" (4) #12 S.S. WOOD SCREWS 3/4" LG. W/ S.S. WASHERS. 20 GA. S.S. CORNER GUARD - TOP OF BASE TO BOTTOM OF CLG. ATTACH W/ CONST. ADHESIVE GRID LINE 3" 2x4 WOOD STUD 4x4 STEEL COLUMN REF. STRUCT. 3" AIR AND MOISTURE BARRIER - REF. SPECS. 1/2" GYPSUM BOARD N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 16 GA. BRUSHED STAINLESS STEEL. 1/2" HEM ON TOP AND FRONT EDGES. 20 GA. S.S. END WALL GUARD - TOP OF BASE TO BOTTOM OF CLG. ATTACH W/ CONST. ADHESIVE 2" FLANGE BENT 90 DEG. SAFE PEDESTAL 1-1/2"=1'-0" YAW020 YAF006 ANCHOR BOLTS - SEE SCOPE OF WORK - BOLT HOLES = 3/4" DIA. x 3" DEEP 2" 19 CORNER GUARD 3"=1'-0" WINDOW SILL BELOW BOTTOM EDGE OF SPLASH GUARD SHALL BE EVEN W/ THE EDGE OF THE HIGHEST ADJ. SINK. NOTE: CAULK ALL SEAMS AT WALL SURFACE. 15 GRID LINE SPLASH GUARD N.T.S. W-6 20 GA. SS CHANNEL ATTACH W/ CONST. ADHESIVE EL. +7'-6" SEALANT + BACKER ROD 1/2" GYP. BD. ON 1x WOOD BLKG. PAW040 CONCRETE FLOOR SURFACE W-4 3" EXTEND FRONT OF PANEL TO FRONT EDGE OF ADJ. SINK. APPROX. 24" (SEE PLAN) GROUT TO MATCH ADJ. FLOOR. 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 2x6 BOX BEAM HEADER 1/2" RAD. EASED CORNER (TYP.) WALL FINISH O/ SUBSTRATE PER PLAN 5/8" CEMENT BD. SIZE 1/2" SMALLER THAN SAFE FOOTPRINT. ALUM. STOREFRONT REF. SPECS. WINDOW SILL BELOW 221" SAFE - SEE SCOPE OF WORK FOR SCOPE DEFINITIONS SEALANT + BACKER ROD ALUM. BRAKE METAL FINISH TO MATCH ALUM. STOREFRONT 11 WINDOW/COLUMN DETAIL 8 3" = 1'-0" BULKHEAD @ PICK-UP 3" = 1'-0" 4 NOT USED 3"=1'-0" 3 WALL (WHERE OCCURS) CEILING TILE & GRID DOUBLE STUDS AT JAMB AND HEAD WITH ANCHOR STRAP. 1/2" GYP. BD. PAINT P-4 J MOLD BELOW SUSPENDED CEILING - FILL J-MOLD W/ SILICONE PRIOR TO INSTALLING FRP, WIPE OFF EXCESS P-1 ST-1 1x1 WOOD TRIM HM FRAME FINISH PER ELEVATIONS ST-1 SUBSTRATE PER PLAN OVER WOOD STUDS @ 16" O.C. W-1 THIN BRICK VENEER OVER 1/2" GYP BD. DOOR TRIM DETAIL 3" = 1'-0" 18 INTERIOR DOOR HEAD / JAMB 3" = 1'-0" YAW039 SUBSTRATE AS NOTED ON SHEET A1.0 YAW022 SEALANT 14 NOT USED 3" = 1'-0" 10 FRP @ CEILING 7 3"=1'-0" WAINSCOT PER ELEVATIONS SUBSTRATE PER PLAN - PROVIDE 1/4" GAP BETWEEN SUBSTRATE & CEMENT BD. BELOW 9'-6" A.F.F. P-3 2x4 WOOD BLOCKING FOR TV'S 1/2" GYP BOARD CEMENT BD. TO 12" ABOVE FLOOR- ALL WALLS (EXCEPT @ FRONT & REAR WALLS). 2x4 WOOD BRACING @ 32" O.C. COVE BASE TILE CONTRACT DATE: CLG. 8'-6" NOT USED N.T.S. 17 NOT USED 3"=1'-0" 13 YAF014 P-1 PAW035 STAINED CONCRETE FLOOR BASE @ RESTROOM 6 3"=1'-0" JAMB @ RESTROOM VESTIBULE 3"=1'-0" 2 1/2" GYP BOARD 1/2" GYP BOARD P-1 09.21.15 BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 FRP STUD WALL SUBSTRATE PER PLAN - PROVIDE 1/4" GAP BETWEEN SUBSTRATE & CEMENT BD. BELOW DRINK COUNTER DOOR AS SCHEDULED CUT FLUSH WITH WALL AND FILL GAPS WITH FOAM. 6" 6" PVC CHASE FROM BELOW CEMENT BD. TO 12" ABOVE FLOORALL WALLS (EXCEPT @ FRONT & REAR WALLS) DOOR SILL. REF: DOOR SCHEDULE 2x4 WOOD BLOCKING FOR TV'S EXPANSION JOINT 2x4 WOOD STUD OR 3 5 8" MTL STUD FRAMING DBR 37 WOOD STUDS @ 16" O.C. J MOLD SET IN SILICONE SEALANT FILL J-MOLD W/ SILICONE PRIOR TO INSTALLING FRP, WIPE OFF EXCESS INTERIOR CONSTRUCTION DETAILS CONC SIDEWALK FIN. FLOOR PAW034 WALL SECTION SYRUP CHASE IN WALL TV - PROVIDED BY PIZZA HUT N.T.S. 16 EXTERIOR DOOR SILL 3"=1'-0" 12 EL. +6'-8" BOTTOM OF 1X TRIM COVE BASE TILE P-3 FURR DOWN DETAIL 3" = 1'-0" 9 A11.0 YAW023 CLG. 7'-0" BOTTOM OF SOFFIT FRP @ KITCHEN BASE 3" = 1'-0" 5 BULKHEAD @ RESTROOM VESTIBULE 3"=1'-0" 1 PLOT DATE: 1 A11.3 3 A11.2 2 A11.2 3" 19'-48 N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 4'-621" 641" 3" 44 11'-25 8" 3'-1" 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 3'-2" 6" 2'-8" 3'-6" 8" 1'-021" 2'-0" 93 4" 2'-2" 2'-8" 8" M-2 5'-021" 5" 5'-1016 9 A11.3 3'-05 8" 4'-221" 1 A11.3 3'-621" 5" 2'-416 M-2 1121" 6'-741" 18'-23 8" 8" 6" AND CLIPS WITH 3/8" TEMPERED GLASS SNEEZE GUARD (TYP.) 6'-0" 3'-0" 3'-341" 7'-0" SERVICE/BAR COUNTER 3 A11.3 1 A11.2 M-2 3/4" = 1'-0" 1 9 A11.3 2'-8" 1'-10" M-2 1'-8" 6" 1" 2'-516 8 A11.3 1'-6" 5'-141" AND CLIPS WITH 3/8" TEMPERED GLASS SNEEZE GUARD (TYP.) 5'-2" 2'-0" 3'-9" CONTRACT DATE: 10'-11" BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: ORDER COUNTER 3/4" = 1'-0" ORDER ENTRY COUNTER 3 3/4"=1'-0" 2 09.21.15 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 7 A11.3 8 SIM. A11.3 11'-1" 1'-6" DBR 37 MILLWORK DETAILS A11.1 NOT USED 1" = 1'-0" 5 NOT USED 3/4"=1'-0" 4 ENTRY ORDER COUNTER 3/4"=1'-0" 4 PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F WOOD TRUSSES - REF. STRUCTURAL WOOD TRUSSES - REF. STRUCTURAL 11'-1 1/2" WOOD TRUSSES - REF. STRUCTURAL 11'-1 1/2" 1/2" GYP. BD. ON 2x4 WOOD FRAMING @ 16" O.C. - PAINT 11'-1 1/2" 1/2" GYP. BD. ON 2x4 WOOD FRAMING @ 16" O.C. - PAINT 1/2" GYP. BD. ON 2x4 WOOD FRAMING @ 16" O.C. - PAINT 3'-8" 3'-8" 2x4 WOOD BRACING @ 32" O.C. 3'-8" 2x4 WOOD BRACING @ 32" O.C. 9'-6" 2x4 WOOD BRACING @ 32" O.C. 9'-6" 9'-6" 1/2" GYP. BD. ON 2x4 WOOD FRAMING @ 16" O.C. - PAINT 1/2" GYP. BD. ON 2x4 WOOD FRAMING @ 16" O.C. - PAINT 1/2" GYP. BD. ON 2x4 WOOD FRAMING @ 16" O.C. - PAINT LIGHT FIXTURE REF. ELEC. LIGHT FIXTURE REF. ELEC. LIGHT FIXTURE REF. ELEC. T.V. - REF. EQUIPMENT PLAN PROVIDE WOOD BLOCKING T.V. - REF. EQUIPMENT PLAN PROVIDE WOOD BLOCKING T.V. - REF. EQUIPMENT PLAN PROVIDE WOOD BLOCKING 1/2" GYP. BD. ON 2x4 WOOD FRAMING @ 16" O.C. - PAINT 1/2" GYP. BD. ON 2x4 WOOD FRAMING @ 16" O.C. - PAINT 1/2" GYP. BD. ON 2x4 WOOD FRAMING @ 16" O.C. - PAINT 7'-0" 7'-0" CL-3 A.C.T. - REF. REFLECTED CLG. PLAN 6 A11.3 7'-0" CL-3 A.C.T. - REF. REFLECTED CLG. PLAN M-2 1/2" SOLID SURFACE ON 3/4" PLYWOOD 921" 2'-0" 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 6 A11.3 M-2 1/2" SOLID SURFACE BEYOND 3'-6" CL-3 A.C.T. - REF. REFLECTED CLG. PLAN 921" 3" 1'-016 2'-8" 97 8" CONTRACT DATE: M-2 1/2" SOLID SURFACE ON 3/4" PLYWOOD M-2 1/2" SOLID SURFACE ON 3/4" PLYWOOD 6 A11.3 1x4 WOOD TRIM STAINED ST-1 6 A11.3 6 A11.3 2'-10" DBR 37 PLAN VERSION: 009.00.00 311465 / 434385 STORE NUMBER: 6 A11.3 2" 2015388.14 PIZZA HUT 3'-6" 123 Minden Shopping Dr. Minden, LA 71055 R-XX3 AMBER LED LIGHT STRIP 1x4 WOOD TRIM STAINED ST-1 BUILDING TYPE: SITE NUMBER: 2'-8" 09.21.15 1x4 WOOD TRIM STAINED ST-1 8" MIN. M-1 PLASTIC LAMINATE OVER 3/4" PLYWOOD ON 2x4 WOOD FRAMING @ 16" O.C. M-1 PLASTIC LAMINATE OVER 3/4" PLYWOOD ON 2x4 WOOD FRAMING @ 16" O.C. FRP-1 FRP M-1 PLASTIC LAMINATE OVER 3/4" PLYWOOD ON 2x4 WOOD FRAMING @ 16" O.C. FRP-1 FRP 1/2" HILTI HIT HY150 1/2" HILTI HIT HY150 ADHESIVE ANCHOR @ 16" O.C. STAGGERED. ADHESIVE ANCHOR @ 16" O.C. STAGGERED. 11" MIN. 1x4 WOOD TRIM STAINED ST-1 1x4 WOOD TRIM STAINED ST-1 B-1 TILE BASE SECTION AT SALAD STATION 1 1/2" =1'-0" B-3 RUBBER BASE 3 MILLWORK DETAILS ADHESIVE ANCHOR @ 16" O.C. STAGGERED. 1/2" HILTI HIT HY150 1x4 WOOD TRIM STAINED ST-1 B-3 RUBBER BASE DBR 37 FRP-1 FRP 6" MIN. B-1 TILE BASE SECTION AT FRONT BAR B-3 RUBBER BASE 1 1/2" = 1'-0" 2 A11.2 B-1 TILE BASE SECTION AT ENTRY POS 1 1/2" = 1'-0" 1 PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 COATED POLES AND CLIPS WITH 3/8" TEMPERED GLASS SNEEZE GUARD 1'-6" NOT USED 1 1/2" = 1'-0" 5 1x4 WOOD TRIM ST-1 M-2 1x4 APRON (STAINED) 1" STL PIPE TO PENATRATE TOP PLATE 3'-07 8" S-XX2 3/4" PLYWOOD 6 A11.3 M-2 6 A11.3 ST-1 EA. SIDE M-2 1/2" SOLID SURFACE ON 3/4" PLYWOOD PT-5 1/2" GYP.BD. 3'-6" 1/2" GYP. BD. 1'-6" COATED POLES AND CLIPS WITH 3/8" TEMPERED GLASS SNEEZE GUARD M-2 3'-6" 2x6 WOOD FRAMING @ 16" O.C. 2x4 WOOD FRAMING @ 16" O.C. FRP-1 2'-10" TREATED SILL PLATE, ANCHOR TO SLAB BASE B-3 2x4 WOOD FRAMING @ 16" O.C. 1/2" HILTI HIT HY150 B-3 CONC. FLOOR F-1 1x4 WOOD TRIM STAINED ST-1 321" B-1 ADHESIVE ANCHOR @ 16" O.C. STAGGERED. GROUTED IN PLACE. SEE A1 FOR LOCATIONS 3'-6" 2x4 WOOD FRAMING @ 16" O.C. B-3 RUBBER BASE LOW WALL AT BOOTH 1 1/2" =1'-0" 10 STEEL POST LOW WALL DETAIL 1 1/2" =1'-0" 8 NOT USED N.T.S. 4 DRINK STATION CABINET SECTION 1 1/2"=1'-0" 2 M-2 1x4 APRON (STAINED) M-1 PLASTIC LAMINATE OVER 3/4" PLYWOOD ON 2x4 WOOD FRAMING @ 16" O.C. 3" ST-1 1x4 WOOD TRIM STAINED ST-1 1'-6" FRP-1 1x4 WOOD TRIM STAINED ST-1 1/2" SOLID SURFACE ON 3/4" PLYWOOD SIM. 3A MITRE & GRIND SHARP EDGES / POINTS M-1 PLASTIC LAMINATE OVER 3/4" PLYWOOD ON 2x4 WOOD FRAMING @ 16" O.C. 1'-6" COATED POLES AND CLIPS WITH 3/8" TEMPERED GLASS SNEEZE GUARD (SEE PLAN FOR LOCATIONS) M-2 M-2 1/2" SOLID SURFACE ON 3/4" PLYWOOD 3" 2" 64 2'-6" COUNTER DETAIL 7 1 1/2" = 1'-0" M-2 1/2" SOLID SURFACE ON 3/4" PLYWOOD 6 11.3 3'-6" 1x4 APRON (STAINED) 1'-321" 921" 6 A11.3 2x4 WOOD FRAMING @ 16" O.C. 1/2" HILTI HIT HY150 1/2" HILTI HIT HY150 ADHESIVE ANCHOR @ 16" O.C. STAGGERED. ADHESIVE ANCHOR @ 16" O.C. STAGGERED. ORDER COUNTER SECTION 1 1/2" =1'-0" 1/2" HILTI HIT HY150 PAW067 B-1 TILE BASE DBR 37 FRP-1 FRP MILLWORK DETAILS 9 COUNTER EDGE DETAIL 3" = 1'-0" 6 1x4 WOOD TRIM STAINED ST-1 ADHESIVE ANCHOR @ 16" O.C. STAGGERED. B-3 2015388.14 123 Minden Shopping Dr. Minden, LA 71055 P-XX1 1x4 TRIM (STAINED) B-3 RUBBER BASE 311465 / 434385 STORE NUMBER: 3'-6" M-1 PLASTIC LAMINATE OVER 3/4" PLYWOOD ON 2x4 WOOD FRAMING @ 16" O.C. 3/4" PLYWD. 1x4 WOOD TRIM STAINED ST-1 009.00.00 3/4" PLYWOOD 3'-6" 1 1/2" FRP-1 2'-10" M-1 PLASTIC LAMINATE OVER 3/4" PLYWOOD ON 2x4 WOOD FRAMING @ 16" O.C. SOLID SURFACE. COUNTERTOP & EDGE. PLAN VERSION: ST-1 3/4" PLYWOOD A DBR 37 PIZZA HUT ST-1 A 09.21.15 BUILDING TYPE: SITE NUMBER: 1x4 WOOD TRIM STAINED ST-1 1x4 WOOD TRIM STAINED ST-1 CONTRACT DATE: 1'-6" 121" 6 A11.3 COATED POLES AND CLIPS WITH 3/8" TEMPERED GLASS SNEEZE GUARD 2 x 2 x 41" ANGLE FRAME - MAX. SPACING 16" O.C. 1x4 LEDGER W/ P. LAM TO MATCH COUNTERTOP. PLAN SECTION A-A 3'-6" 3/4" PLYWOOD C L BOLT, STUD & ANGLE 1'-6" 341" 121" 6" B-3 RUBBER BASE B-3 LOW WALL SECTION 1 1/2" = 1'-0" 3 A11.3 B-1 TILE BASE COUNTER SECTION @ SALAD 1 1/2" = 1'-0" 1 PLOT DATE: 20" MAX MIRROR MTD @ 40" A.F.F. MAX TO BOTTOM OF REFLECTING SURFACE LAV. INSULATE HOT WATER & DRAIN PIPES VERTICAL S.S. GRAB BAR (IF RQ'D) >20-25" MAX DRYER PAPER TOWEL DISPENSER N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F ACCESSIBLE SEATS 121 - 140 7 7" 9" 8" 6" 17"-19" NUMBER OF ACCESSIBLE SEATS 10" MAX. 30" 30" 19" TO 48" A.F.F. FOR OPERABLE OPENING W/O OBSTRUCTION FROM GRAB BAR 24" MAX. 6" MAX. DEPTH x 30" MIN. WIDTH TOE CLEARANCE ALTENATE DOOR LOCATION FREESTANDING OBJECT MOUNTED ON POSTS OR PYLON MAY OVERHANG 12" MAX FROM 27" TO 80" ABOVE FINISH FLOOR 15" MIN. 27"MIN. 12" 4" 15" MIN. 36" MIN. CLR. ACCESSIBLE ROUTE 46" MAX. OBJECT PROJECTION FROM WALL LESS THAN 27" ABOVE FINISH FLOOR MAY PROTRUDE ANY AMOUNT SEATING AND TABLES N.T.S. 18 REACH RANGES 9" 9" N.T.S. 14 REQ'D IN CA ONLY INT. ACCESS. ROUTE CLEARANCES 1/2" = 1'-0" 10 ACCESSIBLE URINAL 3/4" =1'-0" 6 SIGN POST OBSTRUCTION 121" MIN. CLR. 12" MAX 17" MIN. TO 18" MAX TOILET PAPER 4" MAX. VERTICAL GRAB BAR. SEE DTL 1 STANDARD TOILET STALL CLEAR FLOOR SPACE N.T.S. 2 17" MIN. 2- 1/4"x3' EXPANSION ANCHORS AT MASONRY OR CONC. WALL 2- #10x2" SCREWS AT WOOD OR STEEL STUD WALL-TYP. 27" MIN 60" 60" TACTILE CHARACTERS 48" MIN TO BOTTOM OF BRAILLE 60" MAX TO BASELINE OF THE HIGHEST LINE OF TEXT GRAB BAR SHALL BE 1-1/4" TO 2" MAX., OUTSIDE DIA.- TYPICAL 1 6" MAX. (150) ** IF TOILET STALL IS CONSTRUCTED OF SOLID WALLS WITHOUT 9" OF TOE CLEARANCE UNDER PARTITION, PROVIDE ADDITIONAL 6" WIDTH AND DEPTH FLOOR SHALL BE SLIP-RESISTANT SURFACE AND LEVEL WITH MAX 1/4" CHANGE IN LEVEL CONDIMENTS N.T.S. 2'-8" MIN. (815) 48" MIN. 13 1/2" MAX 27" 48" MAX. 30" MIN REQ'D IN CA ONLY CLEAR FLOOR SPACE 80" MIN. OBJECT PROJECTION FROM WALL BETWEEN 27" TO 80" ABOVE FINISH FLOOR SHALL PROTRUDE NO MORE THAN 4" >10-24" MAX ELEVATION FIRE ALARM PROTRUDING OBJECT EXAMPLE: DRINK MACHINE, ETC. 10" MAX THERMOSTAT MOUNTING HTS. & CLEARANCES FOR ACCESSIBILITY BY THE DISABLED 46" MAX. 34" MAX 15" MIN. 48" MAX. CONTROLS MOUNTED ON WIDE SIDE OF TOILET AREA 28"-34" A.F.F. SWITCHES 8" MIN. DEPTH x 30" MIN. WIDTH KNEE SPACE 4'-8" MIN. (1420) W. WALL MOUNTED W.C. 4'-11" MIN. (150) W. FLR. MOUNTED W.C. 6 33" (EXCEPT @ TANK TOILETS, WHICH SHALL BE 36") APPROACH 3'-6"MIN. LATCH APPROACH ONLY, 101 - 120 2'-0" 36" S.S. GRAB BAR 4'-6" MIN. (1320) 5 6" TO 12" MAX OTHER APPROACHES 81 - 100 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 30" MIN. 4 39" to 41" PULL STATION 14" MIN. / 17" MAX. PROJECTION FROM WALL URINAL 12" MAX. (305) 61 - 80 T.S. COVER DISPENSER SHALL BE MOUNTED 1 1/2" (MIN.) BELOW GRAB RAIL 4" MAX. 2'-8" MIN. (815) (100) 3 2. TOP OF GRIPPING SURFACE 33" TO 36" MAX TO THE TOP OF THE BAR. SEE NOTES BELOW 12" MINIMUM CLEAR ABOVE GRAB BAR 18" MIN. FOR CALIFORNIA 15" MIN. 41 - 60 44" MAX. 2 48" MAX. 21 - 40 48" MAX. 1 15" MIN 1. 1 - 20 48" S.S. GRAB BAR NOTES: 30" MIN. TOTAL SEATS 48" MIN. CONTRACT DATE: 1/8"x2" BENT PLATE WELDED TO RAIL AND1/8"x3" DIAMETER MOUNTING PLATE @ 4'-0" ACCESSIBLE ROUTE WALK 2"x6" BLOCKING AT WOOD STUD WALLS (OMIT BLOCKING AT MASONRY OR CONC. WALL) - TYPICAL 15 PROTRUDING HAZARDS 1/2" = 1'-0" MOUNT COAT HOOK ON INSIDE OF TOILET STALL DOOR 11 CHRISTYHARDWARE.COM 877-544-5400 NOTE: SEE DOOR SCHEDULE. AND DOOR SCHEDULE NOTES COAT HOOK 20 30" CLEAR 1/4" - 1/2" 48" A.F.F MAX. PARTITION DOOR LATCH @ PULL ACCESSIBLE LAVATORY 1. 009.00.00 3/4"=1'-0" 3 INDICATED DIMENSIONS, HEIGHTS, DEPTHS, AREAS AND OTHER GRAPHIC INFORMATION ARE PROVIDED AS MINIMUMS THAT MUST BE MAINTAINED. THESE MINIMUMS ARE BASED UPON YUM STANDARDS AND MAY EXCEED ADA REQUIREMENTS. 2. 60" TURNING SPACE - PERMITTED OVERLAP LIMITED TO 1 ARM OF T-SHAPED SPACE - CAN OVERLAP FIXTURE & DOOR CLEARANCE - DOOR CAN SWING INTO TURNING SPACE A MAXIMUM OF 12" 3. RESTROOM, IN GENERAL, DOOR SWING MUST BE OUTSIDE OF THE FXTR CLEAR FLOOR SPACE HOWEVER A DOOR CAN SWING INTO FIXTURE CLEAR FLOOR SPACE IF WHEELCHAIR SPACE 30"X48" IS PROVIDED BEYOND THE DOOR SWING. 4. TOILET ROOM MUST ALLOW FOR SIDE TRANSFER - 42" BETWEEN FIXTURES CHANGES IN LEVEL N.T.S. 12 DINING ROOM SEATING CLEARANCES N.T.S. 8 GENERAL NOTES 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 DBR 37 NOTE: 1. MAINTAIN 36" MIN. CLEAR AISLE EGRESS PATHS TO EXIT DOORS. 2. INTERNATIONAL SYMBOL OF ACCESSIBILITY REQUIRED ON TOP EDGE OR FRONT OF ALL ACCESSIBLE TABLES. 16 311465 / 434385 THE DETAILS SHOWN ARE CONCEPTUAL ONLY AND INTENDED TO SHOW ABSOLUTE MINIMUMS AND SHALL BE COORDINATED WITH THE OTHER CONSTRUCTION DOCUMENTS ASSOCIATED WITH THIS PROJECT. 2 NOTE: SEE DOOR SCHEDULE. AND DOOR SCHEDULE NOTES N.T.S. 7 ACCESSIBLE ROUTE 48" CLEAR 19" 30" CLEAR 1 PLAN VERSION: 30" CLEAR NOTE: DOOR HOOKS SHALL BE PLACED IN ACCESSIBLE STALLS BETWEEN 40" MIN TO 48" MAX ABOVE FINISH FLOOR 34" A.F.F MIN. 48" A.F.F MAX. BOBRICK OR CHRISTY COMMERCIAL HARDWARE & SUPPLY WAREHOUSE #039-6529 OR SIMILAR ADA COMPLIANT HOOK. 3" - 1'-0" 30" CLEAR REINFORCED S.S. LATCH WITH THROUGH BOLTED KEEPER. ADA COMPLIANT S.S. PULL (BOTH SIDES) ON ALL ACCESSIBLE TOILET STALLS. MOUNT PULLS BELOW LATCH AND KEEPER. DBR 37 STORE NUMBER: GRAB BAR 19" 1/4" MAX N.T.S. BUILDING TYPE: SITE NUMBER: ACCESSIBLE ROUTE ACCESSIBLE RESTROOM DOORS 09.21.15 4 PLOT DATE: CLEAR FLOOR SPACE AT DOOR STRIKE SIDE DOOR CLOSER IF PROVIDED, SHALL HAVE AT LEAST A 5-SECOND CLOSING TIME PERIOD FROM 90 OPEN POSITION THRESHOLD - SEE DETAILS 12, 14 / A6.1 32" MIN. CLR. OPENING N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 DOOR AND HARDWARE PER SHEET A1.1 PROVIDE ISA DECAL @ ALL PUBLIC ACCESSIBLE ENTRANCES SLIP RESISTANT SURFACE (MEDIUM BROOM FINISH) 34" TO 44" 60" 10" MIN. CROSS SLOPE 1:50 OR 2% MAX. IN ALL DIRECTIONS. NOTE: 1. EXTERIOR DOOR PRESSURE CANNOT EXCEED 8.5 LBS (GC TO DOOR PRESSURE TO MINIMUM ALLOWABLE BY AHJ). 2. INTERIOR DOOR PRESSURE CANNOT EXCEED 5 LBS. 3. 60% OF PUBLIC ENTRANCES MUST BE ACCESSIBLE. (100% IN CA) 3'-0" DOOR WIDTH TYP. ENTRANCE / EXIT DOOR N.T.S. 17 EXTERIOR DOOR REQUIREMENTS 1/2" = 1'-0" 13 MIN. 60 DEGREE SLOPE 10" MIN. BOTTOM RAIL OF DOOR SEE DETAIL 12 / ADA1.0 1/2" MAX. DOOR HANDLE, SEE HARDWARE NOTES CLEAR SPACE FINISH ELEVATION TO MATCH FINISH FLOOR ELEVATION AT DOOR 18" 24" REQ. IN CA. FOR EXTERIOR DOORS 60" LATCH ALUMINUM THRESHOLD #10 S.M. IN PLASTIC EXPANSION ANCHOR NOT USED N.T.S. 18 BOTTOM RAIL (EXTERIOR DOOR) 3" = 1'-0" 14 NOT USED N.T.S. 2 CONTRACT DATE: BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: NOT USED N.T.S. 11 NOT USED N.T.S. 3 09.21.15 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 DBR 37 ACCESSIBILITY REQUIREMENTS NOT USED N.T.S. 16 NOT USED N.T.S. 12 NOT USED N.T.S. 4 PLOT DATE: GENERAL: 1. 2. FAN DATA LOCATE, CUT AND FRAME ROOF OPENINGS AS SHOWN FOR ALL HVAC EQUIPMENT AND EXHAUST FANS. XX-XXX AREA SERVED SUPPLY MIN O.A. CFM CFM ESP COOLING CAPACITY HP NOM TONS RPM MIN CAP (MBH) NET TOTAL HEATING CAPACITY MIN EER UNIT ELECT DATA INPUT OUTPUT PHASE STAGE AFUE (MBH) (STAGES) (MBH) VOLTS/ PH FLA MCA MOCP MAX UNIT WEIGHT (LBS) IT IS VERY IMPORTANT THAT ACCURATE MEASUREMENTS ARE USED WHEN LOCATING EXHAUST FAN ROOF OPENINGS TO ENSURE THAT NO OFF-SETS ARE REQUIRED IN THE EXHAUST DUCTWORK. COORDINATE ROOF OPENINGS WITH THE KITCHEN EQUIPMENT. MARK PROVIDE ANY FRAMING REQUIRED FOR DIFFUSER INSTALLATION IN HARD CEILING. RTU-1 KITCHEN 5000 1475 1.0" 3.0 1740 12.5 144 12.1 250 203 2 81% 208/3 - 65 90 2500 RTU-2 DINING 4000 1225 1.0" 3.75 1483 10.0 113 11.3 200 160 2 80% 208/3 - 49.6 60 1300 MANUFACTURER AND MODEL NUMBER REMARKS N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 3. HVAC: 1. INSTALLATION SHALL CONFORM TO THE ENERGY CONSERVATION DESIGN MANUAL STANDARDS FOR NEW NONRESIDENTIAL BUILDINGS, IF REQUIRED. 2. ALL WORK AND MATERIALS SHALL COMPLY WITH GOVERNING CODES, SAFETY ORDERS AND REGULATIONS. 3. OBTAIN AND PAY FOR ALL NECESSARY PERMITS, FEES AND INSPECTIONS REQUIRED BY GOVERNING AUTHORITIES. UNLESS NOTED OTHERWISE. 4. PROVIDE CONDUIT FOR LINE AND LOW VOLTAGE WIRING, LINE VOLTAGE WIRING SWITCHES, AND FINAL CONNECTIONS. 5. ANY EQUIPMENT THAT IS SUBSTITUTED SHALL FIT IN THE SPACE PROVIDED WITH ADEQUATE ROOM FOR SERVICING, INCLUDING SUBSTITUTE EQUIPMENT NAMED IN THE SPECIFICATIONS. CONTRACTOR SHALL SUBMIT A 1/4" SCALE DRAWING OF ALL EQUIPMENT SUBSTITUTED FOR APPROVAL PRIOR TO INSTALLATION, INCLUDING, BUT NOT LIMITED TO, STRUCTURAL AND ARCHITECTURAL IMPACT, CLEARANCE REQUIREMENTS AND UTILITY REQUIREMENTS. 6. INSTALL RECHARGEABLE REFRIGERANT LINES FROM ICE MACHINE TO CONDENSER ON ROOF. 7. HVAC UNITS SHALL BE MOUNTED LEVEL ON ROOF CURBS. 8. ALL EXPOSED DUCTWORK TO BE INTERNALLY LINED AND PAINTED AS SHOWN ON ARCHITECTURAL DRAWINGS. ALL OTHER DUCTWORK SHALL BE INSULATED PER THE SPECIFICATIONS. 9. ALL ROUND SUPPLY / RETURN DUCTS SHALL BE RIGID, WITH THE EXCEPTION OF THE LAST 5'-0", WHICH MAY BE FLEX. (ACCESSIBLE CEILINGS ONLY) TRANE YHD150F3 TRANE YSC120E3EM 1,2,3,4,5,6&7 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 1,2,3,4,5,&6 NOTES: 1. LISTED CAPACITY IS NET COOLING CAPACITY AT 97DB/77 WB EAT AND 105F AMBIENT (ARI CONDITIONS). 2. SPECIFIED RTU'S ARE DOWN DISCHARGE PACKAGED GAS / ELECTRIC ROOFTOP UNITS . INCLUDES THROUGH THE ROOF CURB POWER, GAS & CONDENSATE DRAIN. GAS PIPING SHALL BE FACTORY PIPED WITH SHUT-OFF OUTSIDE OF UNIT. 3. GUARD, SMOKE DETECTOR IN RETURN, AND FACTORY FABRICATED KNOCK-DOWN ROOF CURB. 4. SPECIFIED UNIT INCLUDES A UN-POWERED CONVENIENCE OUTLET. 5. SPECIFIED UNIT INCLUDES SUPPLY AIR TEMPERING CONTROL WITH REMOTE MOUNTED TEMPERATURE SENSOR AT 60"AFF, WHERE INDICATED ON PLANS 6. INTERLOCK OPERATION WITH PIZZA OVEN HOOD. SUPPLY FAN ON AND OUTDOOR AIR DAMPER OPEN WHEN HOOD EXHAUST IS ENERGIZED. 7. INTERLOCK OPERATION WITH FRYER HOOD. SUPPLY FAN ON AND OUTDOOR AIR DAMPER OPEN WHEN HOOD EXHAUST IS ENERGIZED. 10. SMOKE DETECTOR SHALL BE INSTALLED IN THE RETURN AIR DUCTS AND SHALL DEACTIVATE ROOFTOP UNIT UPON SENSING SMOKE. REFER ELECTRICAL DRAWINGS. HVAC UNIT SCHEDULE 11. ALL KITCHEN HOOD EXHAUST DUCTS SHALL BE RIGID 16 GA MINIMUM, WELDED DUCT. GRIND ALL WELDS SMOOTH. 12. ALL BRANCH DUCTS FEEDING INDIVIDUAL DIFFUSERS SHALL HAVE DAMPERS AT TAKEOFFS FOR AIR BALANCING. DIFFUSERS SHALL HAVE OPPOSED BLADE DAMPER INSTALLED AT AIRFLOW DEVICE AT AREAS WHERE THE CEILING IS INACCESSIBLE. 13. ALL UTILITY PIPING FOR RTU'S SHALL RUN UP THROUGH ROOF INSIDE EACH UNIT'S ROOF CURB. 14. ALL OUTSIDE AIR INTAKES SHALL BE A MINIMUM OF 10'-0" FROM EXHAUST FANS AND / OR VENTS. MARK 15. NOT USED. EF-1 1800 1.0" 1623 1/2 115/1 EF-2 510 1.0" 1487 1/3 115/1 EF-3 200 0.50" 1504 0.129 115/1 16. FINAL HVAC SYSTEM TESTING AND BALANCING SHALL BE PERFORMED BY THE OWNERS INDEPENDENT AGENT. A RE-TEST IS MANDATORY FOR A FALSE START (I.E. NO POWER UPON AGENT'S ARRIVAL, EQUIPMENT NOT WIRED, ETC.) AND SHALL BE A COST INCURRED BY THE G.C. IN THE EVENT A SYSTEM / STORE RECEIVES A GRADE OF 5 OR BELOW AS A RESULT OF THE HVAC SYSTEM PERFORMANCE OR OPERATIONAL DEFICIENCIES, OWNER WILL REQUEST A RE-TEST AND THE COST FOR SAME SHALL BE ALSO INCURRED BY THE GENERAL CONTRACTOR. X X - X X - X X MANUFACTURER AND MODEL NUMBER D-DR ELECT V-BELT POWER HP/ AMPS BIRD SCREEN RPM BDD SP DISC CFM XX-XXX STARTER ACCESSORIES ACME PDU135RG X X SEE NOTES 1,2,3,5,9,10,11,12 CAPTIVEAIRE DU33HFA COOK 70 ACE-B GREENHECK GB-071 17. TRANE PROGRAMMABLE THERMOSTAT MODEL #BAYSENS019B, PROVIDED WITH TRANE PACKAGE. (QUANTITY PER PLANS) REMARKS SEE NOTES 1,2,3,5,9,10,11,12 SEE NOTES 1,3,5 & 8 1 REMARKS: 1. WEATHERPROOF DISCONNECT SWITCH 2. UNVENTED ROOF CURB EXTENSION 3. ROOF CURB, SHIM LEVEL 4. PROVIDE SUPPLY WASHABLE AIR FILTER 5. PROVIDE L-200 BEARINGS AND FAN HUBS KEYED TO SHAFT 6. SINGLE SIDE OUTSIDE AIR INTAKE 7. PROVIDE SOLID STATE SPEED CONTROLLER 8. ALUMINUM BACKDRAFT DAMPER 9. UL 762 LISTED (GREASE) 10. GREASE DRAIN AND TROUGH 11. HINGED SUB-BASE 12. PROVIDED BY OWNER INSTALLED BY CONTRACTOR 18. TRANE THERMOSTAT SENSOR (REMOTE) MODEL #4190-7015, PROVIDED WITH TRANE PACKAGE. (QUANTITY PER PLANS) 19. THESE DRAWINGS ARE ACCOMPANIED BY SPECIFICATIONS. SEE SPECIFICATIONS FOR FURTHER INFORMATION. CIRCUIT BREAKER CD/SR CEILING DIFFUSER/SUPPLY REGISTER (ARROWHEAD REPRESENTS NUMBER OF THROW) RETURN REGISTER/GRILLE MVD FD (L) EXHAUST REGISTER/GRILLE FLEXIBLE CONNECTION MANUAL VOLUME DAMPER FIRE DAMPER DUCT LINING (1" THICK UNLESS OTHERWISE NOTED) DUCT TRANSITION (RECTANGULAR TO ROUND) FLEXIBLE DUCT (5'-0 MAXIMUM) T T-STAT PROGRAMMABLE THERMOSTAT (PROVIDED WITH TRANE PACKAGE) TS T-STAT THERMOSTAT SENSOR (REMOTE) H CONDENSATE DRAIN DIA. DIAMETER DL DL DOOR LOUVER UC UC DOOR UNDERCUT (3/4" MINIMUM) M FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. E FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. ME X-X 0000 CONNECT/CONNECTION CONTINUATION CONT'R CONTRACTOR CFM CUBIC FEET PER MINUTE DET. DETAIL DISC. DISCONNECT DTR DOWN THRU ROOF EF EXHAUST FAN EXISTING GA. GAGE/GAUGE GC GENERAL CONTRACTOR HVAC MFR. 0 VAR 24x24 X S-2 0 VAR 24x24 X S-3 8 VAR 24x24 X S-4 0 VAR 15x15 X S-5 2 VAR 11x11 X S-6 0 12x12 14x14 X (0) S-7 10 18x10 20x12 X (10) R-1 3 22x22 24x24 X (3) E-1 2 VAR 10x10 X (2) 450-725 (0)4W, (0)3W 250-350 (5)4W, (3)3W 500-700 (0)4W,(0)3W 300-350 (2)4W 50-150 300-500 350-600 1050-1200 200 X X X METAL-AIRE / TITUS 5000-1 / TDC-AA-1 MOUNT TO EXPOSED DUCTWORK. X X X METAL-AIRE / TITUS 5000-1 / TDC-AA-1 AT SHEETROCK CLG. INSTALL DAMPER IN DIFFUSER FACE. X X X X METAL-AIRE / TITUS 5000-1 / TDC-AA-1 FRN SQR TO RND ADAPTER X X X X METAL-AIRE / TITUS 5000-1 / TDC-AA-1 FRN SQR TO RND ADAPTER X X X METAL-AIRE / TITUS 5000-1 / TDC-AA-1 FRN SQR TO RND ADAPTER X X X X X X X X MODEL NUMBER REMARKS X X TITUS (OR EQUAL) 300RL-HD SIDE WALL SUPPLY X X TITUS (OR EQUAL) US301FL SIDE WALL SUPPLY METAL-AIRE / TITUS CC5-FB-TB / 50FF METAL-AIRE / TITUS CC5D / 50F X X MANUFACTURER X X FULLY REMOVABLE FACE, DO NOT INSTALL FILTER HEATING, VENTILATING, AND AIR CONDITIONING MANUFACTURER NOTES: MECHANICAL DIFFUSERS IN SURFACE MOUNTED CEILINGS SHALL BE PROVIDED WITH OPPOSED BLADE DAMPERS. SEE ARCHITECTURAL DRAWINGS FOR CEILING TYPES. CONTRACT DATE: NEW IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY FINAL COUNTS BASED ON LOCATIONS SHOWN ON DRAWINGS. BUILDING TYPE: DBR 37 OUTSIDE AIR PLAN VERSION: 009.00.00 OBD OPPOSED BLADE DAMPER SITE NUMBER: S/S STAINLESS STEEL STORE NUMBER: TYP. TYPICAL UON UNLESS OTHERWISE NOTED UTR UP THRU ROOF MECH. HUMIDISTAT, PROVIDED WITH TRANE PACKAGE. D CONN. (E) SINGLE LINE DUCT BRANCH TAKEOFF FLEX CEILING CONT. RECTANGULAR DUCT ELBOW WITH TURNING VANES FC CLG. (0)4W S-1 OBD CB STEEL EXHAUST AIR DUCT (RISE/DROP) ALUMINUM EA/EXH TRANSFER BACK DRAFT DAMPER EXHAUST BDD RETURN RETURN AIR DUCT (RISE/DROP) CFM RANGE MATERIAL SUPPLY RA/RET MARK DUTY 2 SURFACE SUPPLY AIR (RISE/DROP) ER/EG D AIR CONDITIONING SA/SUP RR/RG XX-XXX MOUNTING LAY-IN A/C , AC DESCRIPTION GRILLE SYMBOL & ABBREV. (NO.) & AIR PATTERN TYPE REGISTER DESCRIPTION DIFFUSER FACE NECK OR SIZE CEILING GRID SIZE DIFFUSER SYMBOL & ABBREV. 10 QUANTITY GENERAL NOTES EXHAUST FAN SCHEDULE (N) OA/OSA 09.21.15 311465 / 434385 2015388.14 PIZZA HUT AIR DEVICE SCHEDULE FURNISHED BY MECHANICAL CONTRACTOR AND INSTALLED BY ELECTRICAL CONTRACTOR. FOR COMPLETE INFORMATION AND PRICING ON THE TRANE HVAC PACKAGE CONTACT MARTY CUSICK, THE YUM! BRANDS ACCOUNT EXECUTIVE AT TRANE NATIONAL ACCOUNTS. TOLL-FREE PHONE: (866) YUM-HVAC or (866) 986-4822 FAX: (502) 499-7870 EMAIL: [email protected] MECHANICAL EQUIPMENT DESIGNATION TRANE HAS AGREED TO SUPPLY AN HVAC PACKAGE CONSISTING OF THE ROOF-TOP UNITS, CURBS, AND THERMOSTATS. RTU'S AS SPECIFIED INCLUDE AN UNPOWERED CONVENIENCE OUTLET (SEE ELECTRICAL) AND AN HACR CIRCUIT BREAKER WHICH PROVIDES UNIT DISCONNECT. TRANE ALSO HAVE AVAILABLE OPTION PACKAGES WHICH INCLUDE SMOKE DETECTORS AND ENUNCIATORS, ECONOMIZERS, AND RTU VARIATIONS SUCH AS HIGH-EFFICIENCY MODELS. ITEM OA RA SA EA PRESSURE EF-1 -- -- -- 1800 -1800 EF-2 -- -- -- 510 -510 EF-3 -- -- -- 200 -200 RTU-1 1475 3525 5000 -- +1475 RTU-2 1225 2775 4000 -- +1225 TOTAL 2700 6300 9000 2510 +190 3 DBR 37 BE PREPARED AT TIME OF ORDER OR QUOTE REQUEST TO PROVIDE ALL PROJECT DETAILS REGARDING SPECIFICATIONS AND QUANTITIES AS SITE SPECIFIC DESIGN MAY NOT MATCH NATIONAL DESIGN. SEE THE SCOPE OF WORK SHEETS FOR ADDITIONAL INFORMATION. 123 Minden Shopping Dr. Minden, LA 71055 HVAC NOTES & SCHEDULES M1.0 MECHANICAL SYMBOLS 12 TRANE PACKAGE N.T.S. 8 AIR BALANCE SCHEDULE 4 PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 R-1 1175 15 TYP OF 3 1 RTU 1 8 26/26 6 5 6 RTU-1 T T RTU-2 14 EF 2 EF 4 S-3 625 S-3 625 2 S-3 625 S-3 625 1 3 14x14 S S-3 625 S-3 625 12 TYP 13 S-3 625 24/20 9 WH 24/14 18/14 14/14 1 S-3 625 1 RTU 2 3 EF 14 24/24 TIGHT TO STRUCTURE 13 S-7 390 S-7 390 S-7 390 S-7 390 10 16 S-7 390 S 18 E-1 100 S-5 S-7 390 50 S-7 390 11 TYP S-7 390 S-7 390 11 S S-7 390 7 17 E-1 100 17 S-5 50 18 CONTRACT DATE: 09.21.15 BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: 2015388.14 PIZZA HUT A. DINING ROOM LIGHT FIXTURE LOCATIONS ARE CRITICAL. COORDINATE DUCTWORK LOCATIONS SO AS NOT TO CONFLICT WITH LIGHT FIXTURE LOCATIONS. 1 RTU UNIT, VERIFY UNIT LOCATION AND SUPPORT WITH BUILDING STRUCTURE. G.C. REFER TO STRUCTURAL. SET OUTSIDE AIR ON RTU AS SCHEDULED ON SHEET M1.0. MAINTAIN WORKING CLEARANCES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. 7 B. THERMOSTATS SHALL BE PROGRAMMABLE THERMOSTAT WITH SUBBASE. REMOTE TEMPERATURE SENSOR. (PROVIDED WITH TRANE PACKAGE). 2 10'-6"x 4'-0" TYPE I PIZZA OVEN EXHAUST HOOD AND FANS PROVIDED BY OWNER AND INSTALLED BY GC. REFER TO DETAIL 1/M3.0 FOR MORE INFO. C. DIFFUSERS INSTALLED IN THE EXPOSED STRUCTURE AREAS SHALL BE MOUNTED FLUSH TO THE BOTTOM CORD OF THE TRUSSES. 3 FIELD INSTALL 14"x14" EXHAUST CONNECTION TO HOOD, ROUTE 16"x16", 16 GA. EXTERNAL CONTINUOUSLY WELDED LIQUID TIGHT EXHAUST DUCT FROM OVEN HOOD UP THRU ROOF TO EF-1. MINIMUM 1 HOUR, U.L. LISTED, FIRE RATED BLANKET WRAP UP TO EF-1 ON ROOF. OFFSET DUCT ABOVE AS REQUIRED AND SLOPE DUCT BACK TO HOOD. TRANSITION TO HOOD AND FAN CONNECTIONS AS REQUIRED. PROVIDE AND INSTALL ACCESS DOOR IN DUCT AT EACH CHANGE OF DIRECTION PER CODE. D. DIFFUSERS LOCATED AROUND PERIMETER OF KITCHEN HOODS SHALL BE DIRECTED AWAY FROM THE HOOD. REFER TO PLAN FOR BLOW PATTERN INDICATIONS. 4 5 6 3'-0" X 2'-6" TYPE I FRYER HOOD PROVIDED BY OWNER AND INSTALLED BY GC. REFER TO SHEET M3.0 FOR MORE INFO. 8"x8", 16 GA. WELDED STEEL EXHAUST DUCT WITH MINIMUM 1 HOUR, U.L. LISTED, FIRE RATED BLANKET WRAP UP TO EF-2 ON ROOF. REFER TO SPECIFICATIONS. OFFSET DUCT ABOVE AS REQUIRED AND SLOPE DUCT BACK TO HOOD. TRANSITION TO HOOD AND FAN CONNECTIONS AS REQUIRED. PROVIDE AND INSTALL ACCESS DOOR IN DUCT AT EACH CHANGE OF DIRECTION PER CODE. LOCATE THERMOSTAT CONTROLS ON WALL NEAR MANAGERS DESK AT 48" A.F.F. COORDINATE WITH EQUIPMENT INSTALLED. INSTALL REMOTE TEMPERATURE IN RETURN AIR DUCT FOR RTU-2. SEE SPECIFICATIONS. 15 8 RTU-1 SHALL HAVE A THERMOSTAT WITH NO REMOTE SENSOR. 16 9 FURNISH AND INSTALL 3" DIAMETER FLUE VENT AND 3" DIAMETER INTAKE FROM WATER HEATER THROUGH ROOF AND TERMINATE PER MANUFACTURER'S REQUIREMENTS. COORDINATE WORK WITH ALL TRADES. SEE DETAIL 1/P6.0. INSTALL PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. PROVIDE 22"x48" OPENING IN TOP OF RETURN AIR DUCT. COVER RETURN AIR DUCT OPENING WITH 1"x 16 GA EXPANDED METAL (78% FREE AREA) IN 1-1/4"x1-1/4"x1/8"STL ANGLE FRAME. 17 UNDERCUT RESTROOM DOORS A MINIMUM 3/4" FOR MAKE-UP AIR. 18 CONDENSING UNITS FOR COOLER/FREEZER AND ICE MACHINE MOUNTED ON FIELD FABRICATED PLATFORM ON THE ROOF. ROOF PENETRATIONS AND LEVEL SUPPORT BY THE G.C. SEE ARCHITECTURAL ROOF PLAN. 10 SUPPLY OR RETURN DUCTWORK RUN BETWEEN ROOF TRUSSES ABOVE BOTTOM CORD OF TRUSSES. 11 EXPOSED DUCTWORK IN DINING SHALL BE SUITABLE TO RECEIVE FIELD PAINT AS SCHEDULED. SEE ARCH SHEETS FOR FINISH. 12 ROUTE DUCTWORK BELOW BOTTOM CORD OF THE TRUSSES ABOVE THE CEILING. COORDINATE ROUTING OF DUCTWORK WITH LIGHTS. 13 ROUTE SUPPLY AIR DUCT AND RETURN AIR DUCT UP BETWEEN TRUSSES. TRANSITION IN ROOF CURB TO ROOF TOP UNIT AND INSTALL FLEXIBLE CONNECTION AT CONNECTION TO UNIT. 14 SMOKE DETECTORS ARE FACTORY INSTALLED IN THE RETURN AIR SECTIONS OF THE RTU. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. ABOVE. 123 Minden Shopping Dr. Minden, LA 71055 DBR 37 DUCT AND DIFFUSER PLAN M2.0 PLOT DATE: REVISIONS N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F TAG 1 E56370035+E56370069 MODEL EXHAUST PLENUM MAX. RISER(S) COOKING TOTAL EXH. WIDTH LENG. DIA. CFM TEMP. CFM LENGTH 3347 3' 0.00" 450 Deg. 8" 510 BD-2 510 HOOD CONFIG. HOOD CONSTRUCTION S.P. -0.205" 430 SS Where Exposed END TO END ROW ALONE ALONE 3" 8" 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 BUILT IN ACCORDANCE WITH NFPA No. 96 HOOD NO. 33" 1 E56370035+E56370069 HOOD NO. QTY. HEIGHT TYPE LENGTH 16" 2 SS Baffle with Handles QTY. TYPE 30% 1 L55 Series E26 FIRE SYSTEM TYPE UTILITY CABINET(S) ELECTRICAL SIZE MODEL # SWITCHES QUANTITY FIRE HOOD SYSTEM HANGING PIPING WGHT NO YES 18" 18" Front, Left, Right BACKSPLASH 96.00" High X 72.00" Long E56370035+E56370069 U.L. Listed L55 Series E26 Canopy Light Fixture High Temp Assembly 148 LBS OPTION FIELD WRAPPER 15.00" High 1 EFFICIENCY @ 9 MICRONS 16" TAG WIRE LOCATION GUARD R LIGHT(S) 430 SS Vertical RIGHT QUARTER END PANEL 23" Top Width, 0" Bottom Width, 23" High 430 SS 3' 0.00"Nom./3' 0.00"OD LEFT QUARTER END PANEL 23" Top Width, 0" Bottom Width, 23" High 430 SS L55 SERIES E26 CANOPY LIGHT FIXTURE HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE) 33" FIELD WRAPPER 15.00" HIGH (SEE HOOD OPTIONS TABLE) DALLAS OFFICE EXHAUST RISER 4" 16" SS BAFFLE WITH HANDLES AND HOOK 14" NOM. 3" INTERNAL STANDOFF IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 47" 47.0" MAX 100" BACKSPLASH 96.00" HIGH X 72.00" LONG GREASE DRAIN WITH REMOVABLE CUP 71" AFF REFERENCE FIELD INSTALLED QUARTER END PANELS TAG 1 E56370039 FAN UNIT MODEL # CFM ESP. RPM H.P. B.H.P. VOLT FLA WEIGHT (LBS.) 19 1/2" SONES 19 1/2" DU33HFA 510 1.000 1487 0.333 0.2200 1 115 5.6 62 11.5 FAN #1 DU33HFA - EXHAUST FAN (E56370039) VENTED CURB FEATURES: FAN UNIT NO. TAG 1 E56370039 OPTION (Qty. - Descr.) - ROOF MOUNTED FANS 25 1/2 - RESTAURANT MODEL 1 - Grease Box - UL705 AND UL762 1 - Hinge Kit - Ships Loose for Curb Supplied by Others - VARIABLE SPEED CONTROL 22" 20 GAUGE STEEL CONSTRUCTION - INTERNAL WIRING - WEATHERPROOF DISCONNECT - THERMAL OVERLOAD PROTECTION (SINGLE PHASE) EXHAUST FAN UNIT NO. SUPPLY - GREASE CLASSIFICATION TESTING TAG GREASE CUP 1 E56370039 GRAVITY DAMPER WALL MOUNT SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER WALL MOUNT NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY 25 1/4 YES 18 1/2 NO. ON FAN WEIGHT ITEM 1 #1 30 LBS Curb 3" FLANGE SIZE UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. GREASE DRAIN ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS 19.500"W x 19.500"L x 22.000"H Vented 2 12 1/8 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. OPTIONS 17 1/2 17 1/2 17 1/2 ROOF OPENING DIMENSIONS CARROLLTON, TX, 75007 FAN UNIT NO. Pizza Hut MUA 11 DBR 37A EQUIPMENT BY OTHERS 1901 Royal Lane Suite 101, DALLAS, TX, 75229 PHONE: (214) 220-3999 FAX: (214) 220-0099 EMAIL: [email protected] TAG www.captiveaire.com FILTER(S) HOOD NO. CONTRACT DATE: 09.21.15 BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 DATE: DWG.#: 2322728 DRAWN DJL-45 BY: SCALE: MASTER DRAWING DBR 37 SHEET NO. HOOD DWGS. GREASE BOX HINGE KIT - SHIPS LOOSE FOR CURB SUPPLIED BY OTHERS 21 DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) M3.0 PLOT DATE: REVISIONS N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F LOCATION ON HOOD 1 E56370036 Ansul R102 3.0 8 Wall Mount Left N/A QTY. BY DIST. 0 - 0 - METALCAP-CB BLOWOFF CAP - Metal 4 0 1 - 1 - AT - 3.0 TANK(#1B) - 3.0 Gallon SS Tank (for use with Automan Release, Actuator, or SS Enclosure (UL/ULC)) 0 1 2 - 2 - AP - AR AUTOMAN RELEASE - Ansul Automan Mechanical Release (UL)429853 Tank sold separately 0 1 5 - 5 - LIQ-3.0 AGENT - Ansulex Low PH Wet Chemical Agent, 3 Gallon (UL) 79372 0 1 - APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE. 7 - 7 - 101-20 CARTRIDGE - Carbon Dioxide 101-20, 3 Gallon Cartridge (R-102) 0 1 10 - 10 - TLINK LINK - Test Link (1 test link) 0 1 11 - 11 - MICRO-SDA MICROSWITCH - Single Dual Electric Switch, One Standard Switch, One Alarm Duty Switch 437155 0 1 14 - 14 - 419336 NOZZLE - 1W Nozzle, Duct/Appliance (Replaces ANSUL Part# 419347, CAS Part# 419336) A0001266 1 0 16 - 16 - 419335 NOZZLE - 1N Nozzle, Plenum/Appliance (Replaces ANSUL Part# 419346, CAS Part# 419335) A0001265 1 0 19 - 19 - 419338 NOZZLE - 3N Nozzle, Appliance (Replaces ANSUL Part# 419349, CAS Part# 419338) A0001268 2 0 26 - 26 - QSA-3/8 QUIK SEAL - 3/8" (UL) 4 0 27 - 27 - QPSA-1/2 PULLEY SEAL - 1/2" Hood Seal (UL) 1 0 28 - 28 - S-DET DETECTOR - Series (Scissor Linkage) NEW#435547/435548 (OLD#417369/434480) 1 0 30 - 30 - ANS-500FL FUSIBLE LINK - 500deg F, R-102 and PIRANHA 1 0 34 - 34 - RPS-A REMOTE PULL STATION - Red composite (without wire rope) 434618 (Old Macola #06-4835) 0 1 35 - 35 - PE-LT PULLEY ELBOW - Low Temp. Pulley Elbow, Set Screw Type ANSUL Part #415670 0 10 36 - 36 - PE-HT PULLEY ELBOW - High Temp Pulley Elbow, Compression Type 1 0 Plenum Duct 24" - THIS FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS 24" Hood # 1 (E56370035+E56370069) Job #: 2322728 Job Name: Pizza Hut MUA 11 DBR 37A Drawn By: System Size: ANSUL-3.0 Total FP required: 8 Hood # 1 3' 0.00" Long x 33" Wide x 47" High Riser # 1 Size: 8" Dia. Hood # 1 Metal Blow-Off Caps included. 1W 34 1B 2 30 5 7 28 10 11 21.5" 16" 1N10" 10" 3N 3N Fryer-M w/Drip Board High Proximity 16.00" L x16.00" D E56370036 KEY NUMBER - PART DESCRIPTION Fryer-M w/Drip Board High Proximity 16.00" L x16.00" D 1 QTY. BY FACTORY TAG 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 PLENUM PROTECTION NOZZLE DUCT PROTECTION NOZZLE DETECTORS AGENT LINE Job #: 2322728 Job Name: Pizza Hut MUA 11 DBR 37A Drawn By: System Size: ANSUL-3.0 Total FP required: 8 Hood # 1 3' 0.00" Long x 33" Wide x 47" High Riser # 1 Size: 0" x 0" SYSTEM CONTROL AUTOMAN WITH AGENT TANK ENCLOSED REMOTE MANUAL PULL STATION NOTES - FIELD PIPE DROPS AS SHOWN SLEEVING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - MAXIMUM 9 ELBOWS IN SUPPLY LINE. - MINIMUM 72 INCHES OF AGENT LINE FROM TANK TO FIRST NOZZLE. - IF APPLICABLE, PRE-PIPED CHARBROILER DROPS ARE SHIPPED LOOSE. - FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. - APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE. - THIS FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS SPECIFICATIONS THE RESTAURANT FIRE SUPPRESSION SYSTEM SHALL BE THE PRE-ENGINEERED TYPE WITH A FIXED NOZZLE AGENT DISTRIBUTION NETWORK. IT SHALL BE LISTED WITH UNDERWRITERS LABORATORIES, INC. (UL) THE SYSTEM SHALL BE CAPABLE OF AUTOMATIC DETECTION AND ACTUATION WITH LOCAL OR REMOTE MANUAL ACTUATION. ACCESSORIES SHALL BE AVAILABLE FOR MECHANICAL OR ELECTRICAL GAS LINE SHUT-OFF APPLICATIONS. THE EXTINGUISHING AGENT SHALL BE A POTASSIUM CARBONATE, POTASSIUM ACETATE-BASED FORMULATION DESIGNED FOR FLAME KNOCKDOWN AND SECUREMENT OF GREASE RELATED FIRES. IT SHALL BE AVAILABLE IN PLASTIC CONTAINERS WITH INSTRUCTIONS FOR LIQUID AGENT HANDLING AND USAGE. THE REGULATED RELEASE MECHANISM SHALL BE COMPATIBLE WITH A FUSIBLE LINK DETECTION SYSTEM. THE FUSIBLE LINK SHALL BE SELECTED AND INSTALLED ACCORDING TO THE OPERATING TEMPERATURE IN THE VENTILATING SYSTEM. THE FUSIBLE LINK SHALL BE SUPPORTED BY A DETECTOR BRACKET/ LINKAGE ASSEMBLY. 1A 1.5 GALLON TANK 1B 3.0 GALLON TANK 2 AUTOMAN RELEASE 3 3 GALLON TANK ENCLOSURE 3A 6 GALLON TANK ENCLOSURE 4 REGULATED ACTUATOR 5 ANSULEX LIQUID AGENT (3 GAL.) 6 ANSULEX LIQUID AGENT (1.5 GAL.) 7 CARTRIDGE (101-20) 8 CARTRIDGE (101-10) 9 CARTRIDGE (101-30) 9A CARTRIDGE (LT-A-101-30) 9B DOUBLE TANK CARTRIDGE 10 TEST LINK 11 DOUBLE MICROSWITCH 2W DUCT NOZZLE (419337) 1W NOZZLE ASSEMBLY (419336) 1F NOZZLE ASSEMBLY (419333) 1N NOZZLE ASSEMBLY (419335) 1/2N NOZZLE ASSEMBLY (419334) 3N NOZZLE ASSEMBLY (419338) 245 NOZZLE ASSEMBLY (419340) 230 NOZZLE ASSEMBLY (419339) 2120 NOZZLE ASSEMBLY (419343) 290 NOZZLE ASSEMBLY (419342) 260 NOZZLE ASSEMBLY (419341) 28 DETECTOR BRACKET 29 LOW TEMP FUSIBLE LINK 30 HIGH TEMP FUSIBLE LINK MGV MECHANICAL GAS VALVE EGV ELECTRICAL GAS VALVE 34 REMOTE MANUAL PULL STATION S SWIVEL ADAPTOR CARROLLTON, TX, 75007 APPLIANCE PROTECTION NOZZLE Pizza Hut MUA 11 DBR 37A DETECTION LINE 1901 Royal Lane Suite 101, DALLAS, TX, 75229 PHONE: (214) 220-3999 FAX: (214) 220-0099 EMAIL: [email protected] SYSTEM BUILT IN ACCORDANCE WITH NFPA No. 96 FLOW POINTS R SIZE www.captiveaire.com TYPE DALLAS OFFICE Tag FIRE SYSTEM NO. NOTES - FIELD PIPE DROPS AS SHOWN SLEEVING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - MAXIMUM 9 ELBOWS IN SUPPLY LINE. - MINIMUM 72 INCHES OF AGENT LINE FROM TANK TO FIRST NOZZLE. - IF APPLICABLE, PRE-PIPED CHARBROILER DROPS ARE SHIPPED LOOSE. - FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. INSTALLATION FIRE SYSTEM NO. CONTRACT DATE: 09.21.15 BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 DATE: DWG.#: 2322728 DRAWN DJL-45 BY: SCALE: MASTER DRAWING SHEET NO. DBR 37 HOOD DWGS. M3.1 PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 CONTRACT DATE: 09.21.15 BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 DBR 37 HOOD DWGS. M3.2 PLOT DATE: KITCHEN HOOD EXHAUST FAN 40" MIN. DISCHARGE HEIGHT N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F NEMA 3R DISCONNECT FACTORY WIRED FROM MOTOR TO DISCONNECT THROUGH THE BREATHER TUBE 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 NOTE: LOCATE EXHAUST FANS MIN. 10'-0" FROM ANY OUTSIDE AIR INTAKE FIRE-PROOF INSULATION LIQUID TIGHT FLEXIBLE CONDUIT VENTED CURB EXTENSION MIN. 16" GA. WELDED EXHAUST DUCT - EXTEND MIN. OF 18" ABOVE ROOF DECK PER NFPA ROOF PREFABRICATED GALV. STEEL CURB WITH INSULATION. GREASE TRAP NOT USED N.T.S. 5 EXHAUST FAN N.T.S. 1 STANDARD CURB CAP, FASTEN PER MFR'S RECOMMENDATIONS FACTORY INSTALLED DISCONNECT & CONDUIT CHASE, PROVIDE POWER TO DISCONNECT WITHIN CURB OPPOSED BLADE DAMPERS METAL EXHAUST DUCT RESTROOM FAN KITCHEN GREASE EXHAUST HOOD FIRE SUPPRESSION SYSTEM: N.T.S. 2 ALL-THREADS ROD THE EXHAUST HOOD MANUFACTURER SHALL FURNISH AND INSTALL A KITCHEN EXHAUST HOOD FIRE SUPPRESSION INSTALLED TO MEET ALL NFPA AND LOCAL CODE REQUIREMENTS. SUPPLY WASHER & NUT THE SYSTEM SHALL INCLUDE: 1. CYLINDER CONTROL HEAD GASKET 2. PIPING HOOD MOUNTING CHANNEL ON HOOD L 3. CYLINDERS - CONTAINING FIRE SUPPRESSION CHEMICAL AGENT TO MEET ALL LOCAL CODE REQUIREMENTS 4. FIRE SUPPRESSION NOZZLE AS REQUIRED BY THE KITCHEN EXHAUST HOOD AND KITCHEN EQUIPMENT HOOD TRANSITION TO ROUND SEE PLANS FOR SIZE (WHERE OCCURS) 5. REMOTE MANUAL PULL STATION 6. FUSIBLE LINKS NOTE: L = 4" MIN. OR 1/4 OF "W" BRANCH DUCT - RECTANGULAR OR ROUND W CONTRACT DATE: 7. AUTOMATIC GAS SHUT-OFF VALVE & SHUNT TRIP FOR ELECTRICAL DEVICES UNDER HOOD 8. CORNER PULLEYS YMC001 BUTTERFLY DAMPER WITH ARM & LOCKING QUADRANT (TYPICAL) THE FIRE SUPPRESSION SYSTEM SHALL BE INTERLOCKED WITH THE HVAC, GAS, ELECTRICAL AND BUILDING FIRE ALARM SYSTEMS AS REQUIRED BY CODE. BOLT CONNECTION TO HOOD THE FIRE SUPPRESSION SHALL BE PROVIDED WITH A POWER BACK-UP SYSTEM TO ALLOW THE SYSTEM TO OPERATE WHEN ELECTRICAL POWER TO THE SPACE IS DISCONNECTED. N.T.S. 3 LOW VELOCITY DUCT BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: 2015388.14 PIZZA HUT INSULATED FLEX DUCT - PROVIDE SHORT RADIUS RIGID METAL ELBOW WHERE 18" R. FLEX ELBOW CANNOT BE MAINTAINED THE CONTRACTOR SHALL SCHEDULE AND CONDUCT ALL TESTS AND INSPECTIONS REQUIRED FOR THE APPROVAL OF THE FIRE SUPPRESSION SYSTEM. 09.21.15 123 Minden Shopping Dr. Minden, LA 71055 TRUNK DUCT DIRECTION OF AIR FLOW STRAP HANGER DUCTWORK: KITCHEN HOOD GREASE EXHAUST DUCTWORK: NYLON STRAP FASTENER (TYP) BLACK STEEL WELDED CONSTRUCTION (16 GA) TO BE FABRICATED AND INSTALLED PER SMACNA STANDARDS AND SPECIFICATIONS AND ALL LOCAL CODE REQUIREMENTS. 1 1/2" DUCT WRAP INSULATION EXHAUST RETURN SUPPLY DBR 37 L . IN .M "R 18 THE KITCHEN HOOD EXHAUST DUCTWORK SHALL BE COVERED WITH A 1-HR CODE APPROVED FIRE RATED INSULATION. THE CONTRACTOR SHALL INCLUDE IN HIS PRICE: W - ALL NECESSARY TRANSITION AND CONNECTION FITTINGS TO THE HOOD AND EXHAUST FANS. NOTE: MAXIMUM ALLOWABLE LENGTH OF FLEX DUCT RUNOUTS TO SUPPLY DIFFUSERS = 5'-0". FLEX DUCT IS NOT ALLOWED ON EXHAUST, RETURN OR EXPOSED DUCTWORK. - ALL CLEAN-OUT ACCESS PANELS AS REQUIRED BY CODE. - ALL ELBOW AND TRANSITION FITTINGS. L = 4" MINIMUM OR 1/4 OF "W" MECHANICAL DETAILS BRANCH DUCT RECTANGULAR OR ROUND TOP CONNECTION PMF002 - ALL HANGERS AND SUPPORTS. SIDE CONNECTION - SHOP DRAWINGS SHOWING PROPOSED FABRICATION AND INSTALLATION COORDINATED WITH EXISTING FIELD CONDITIONS AND OTHER TRADES. HOOD EXHAUST NOTES NO SCALE 7 CEILING DIFFUSER CONNECTIONS N.T.S. 6 DUCT CONNECTION DETAIL N.T.S. 4 M4.0 PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 CONTRACT DATE: 09.21.15 BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 DBR 37 HVAC SPECIFICATIONS M5.0 PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 CONTRACT DATE: 09.21.15 BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 DBR 37 HVAC SPECIFICATIONS M5.1 PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F HWR HWR HOT WATER RETURN N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 F E 10 2-WAY CO ECO S 1 S FS 1 5 1 S 1 V V FCO CO 2-WAY CO 8 1 ECO SEWER 1 V FCO 12 17 B.I.B. 1 S 2 DM 9 1 11 FS S 1 3 10 CD 1 FD CD 1 FS CO 13 1 FS 13 4 3 HD C 5 2 2"V 3"V UP IN WALL COORDINATE WITH STRUCTURAL SHEAR WALL CONSTRUCTIONS. 1 12 CD 1 S 2"V 1 FD 1 4" 1 15 1 S GW ECO GI D 1 FD GW 16 2-WAY CO 14 1 1 FD 1 GW 4" 2-WAY CO 1 SEWER 4" V 1 5 CD TO SANITARY MAIN 18 RTU V ECO 6 3"VTR RTU 1 1 2 V 1 WC 1 L FD 7 1 V 1 L 1 FD 4 B 1 1 S S S S 6 3"VTR WC CO 1 WCO 1 A CONTRACT DATE: BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 12 10 11 9 8 7 6 5 4 3 2 A. REFER TO RISER DIAGRAM ON SHEET P5.0 FOR ALL WASTE AND VENT SIZES. F E GENERAL NOTES D A ROUTE WASTE LINE FROM DISHWASHER TO FLOOR SINK WITH INDIRECT WASTE CONNECTION. PROVIDE AIR GAP PER LOCAL CODE. 1 PROVIDE WITH TRAP PRIMER AND CONNECT TO NEAREST CW PIPING. 2 PROVIDE CONDENSATE LINE AND DRAIN LINE FROM ICE MACHINE TO FLOOR SINK, PROVIDE AIR GAP PER LOCAL CODE. 12 GREASE WASTE PIPING SHALL BE COMBINATION WASTE AND VENT. 3 PROVIDE WASTE LINES FROM BEVERAGE UNIT/ICE BIN TO HUB DRAIN, PROVIDE AIR GAP PER LOCAL CODE. 13 ROUTE DRAIN LINE FROM BEER DISPENSER/HAND SINK TO FLOOR SINK, PROVIDE AIR GAP PER LOCAL CODE. 4 PROVIDE 3/4" COPPER CONDENSATE FROM DRAIN PROVIDED BY VENDOR TO OUTFALL AT MOP SINK (HEAT TAPE IS SUPPLIED WITH FREEZER CONDENSATE). 14 SAMPLE WELL BASIN. SEE SITE UTILITY DRAWING FOR EXACT LOCATION . SEE DRAWING SHEET P7.0 FOR DETAILS. 5 CONDENSATE DRAIN FROM HVAC UNITS ON ROOF, RUN ABOVE CEILING TO AND DROP DOWN TO DISCHARGE TO MOP SINK. 15 6 VENT UP THROUGH ROOF. SEE DRAWING SHEET P5.0 FOR ALL VENT AND PIPE SIZING. OFFSET 2" VENT AT A MINIMUM OF 45 DEGREES FOR AT LEAST 6" PRIOR TO HORIZONTAL TRANSITION. EXTEND VENT TO/UP EXTERIOR WALL TO ROOF AS INDICATED. THIS VENT MAY NOT TIE INTO ANY OTHER VENT UNTIL IT REACHES A HEIGHT OF A MINIMUM OF 6" ABOVE FLOOD RIM LEVEL OF HIGHEST FIXTURE SERVED. 7 PROVIDE 3/4" COPPER CONDENSATE FROM EVAPORATOR COILS IN COOLER. ROUTE TO MOP SINK AND MAINTAIN A 2" AIR GAP ABOVE FLOOD RIM. LOCATION OF CONDENSATE SHALL BE LOCATED AS HIGH AS POSSIBLE IN COOLER TO ALLOW SHELVING INSTALLATION. 8 DO NOT ROUTE PIPING OVER ELECTRICAL PANEL. 9 PROVIDE CONDENSATE LINE AND DRAIN LINE FROM DISHWASHER TO FLOOR SINK, PROVIDE AIR GAP PER LOCAL CODE. 10 ROUTE WASTE LINE FROM SINK TO FLOOR SINK WITH INDIRECT WASTE CONNECTION. PROVIDE AIR GAP PER LOCAL CODE. 11 1/4"=1'-0" 16 1000 GALLON GREASE INTERCEPTOR. SEE SITE UTILITY DRAWING FOR EXACT LOCATION . SEE DRAWING SHEET P7.0 FOR DETAILS. 17 6" PVC CHASE FROM BAG-IN-BOX LOCATION TO DRINK DISPENSERS ROUTED BELOW SLAB. 18 EXTEND AND CONNECT NEW WASTE TO EXISTING SANITARY SEWER. VERIFY EXACT LOCATION AND CONNECTION REQUIREMENTS. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS FOR ROUTING AND CONNECTION OF WASTE LINES. KEY NOTES 311465 / 434385 STORE NUMBER: 1 WASTE AND VENT PLAN 09.21.15 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 DBR 37 WASTE AND VENT PLAN P2.0 B PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 F E 3 9 S MV 1 1 S 3 9 5 S MV 1 1 20 7 RTU 1 3 9 S MV 1 1 MV 11 15 7 9 1 1 D CW 21 HW WH 2 HWR 19 B.I.B. 1 4 HW HWR 5 8 3 S 6 NEW GAS METER AT METER BANK APPROXIMATELY 75' AWAY. COORDINATE INSTALLATION OF NEW GAS METER AND REGUALTOR WITH LOCAL UTILITY COMPANY. CW 2 S 22 CW 4 1 17 11 1 DM 14 S S 3 RTU 18 16 2 C 13 WC 1 L MV 1 1 12 9 10 L MV 1 1 12 9 B S S S S 10 13 WC 1 A CONTRACT DATE: BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 12 10 11 9 8 7 6 5 4 3 2 A. NO ROOF PENETRATIONS PERMITTED WITHIN THE ROOF "WATER VALLEYS", REFER TO ROOF PLAN FOR LOCATIONS. 1 2" GAS DOWN TO OVENS. SEE OVEN GAS PIPING DETAIL ON SHEET P6.0. 13 1/2" CW DOWN TO WATER CLOSET. PROVIDE 3/8" STOP. 2 1 1/4" GAS DOWN TO WATER HEATER WITH GAS COCK, DIRT LEG, AND UNION. 14 SLEEVE GAS LINE THRU WALL AND SEAL WATER TIGHT. B. 3 1/2" TEMPERED WATER DOWN IN WALL TO HAND SINK. 15 DO NOT ROUTE WATER LINES OVER ELECTRICAL PANELS. 4 1" HOT AND COLD WATER DOWN TO WATER HEATER. REFER TO DETAIL ON SHEET P6.0. 16 RISE REFRIGERANT LINES UP THRU ROOF TO REMOTE CONDENSING UNITS VIA MULTIPLE PIPE FLASHING. REFER TO ROOF PLAN ON SHEET A3.0. 5 3/4" CW RISE AND VALVE WATER LINES LINE DOWN TO WATER FILTER SERVING BEVERAGE DISPENSER AND TEA BREWER. COORDINATE WITH BEVERAGE COMPANY FOR CONNECTIONS TO TAKE PLACE INSIDE THE CABINET. PROVIDE IN-LINE ASSE 1022 BACKFLOW PREVENTER AND SHUT OFF VALVE AT EACH UNIT. TEA BREWER WATER SUPPLY MUST BE METAL BRAIDED HOSE. 17 RISE AND VALVE WATER LINES ABOVE FLOOR, BELOW BAR, TO SERVE BAR SINK. 18 PROVIDE 3/4"HOT WATER TO DISHWASHER. CONTRACTOR SHALL PROVIDE AND INSTALL WATER HAMMER ARRESTOR (PDI SIZE A, ASSE 1010) AND 25 PSI PRESSURE REGULATING VALVE WITH INTERNAL THERMAL EXPANSION BY-PASS ON SUPPLY LINE. CONTRACTOR SHALL INSTALL VACUUM BREAKER AND ALL ACCESSORIES PROVIDED WITH THE DISHWASHER PER MANUFACTURER'S RECOMMENDATIONS. WATER DISTRIBUTION PIPING IS SHOWN ABOVE FINISHED CEILING. UNDERSLAB DISTRIBUTION ALLOWED AT CONTRACTOR OPTION. COORDINATE ALL DETAILS. NO JOINTS ALLOWED IN WATER PIPING LOCATED BELOW SLAB. C. REFER TO SHEET P5.0 FOR WATER AND GAS ISOMETRIC DRAWINGS. REFER TO ISOMETRIC DRAWINGS FOR PIPE SIZES. F GENERAL NOTES E 6 3/4" HOT AND COLD WATER DOWN IN WALL TO 3-COMPARTMENT SINK. INSTALL WATTS NO.9N BACKFLOW PREVENTER FOR EACH WATER LINE CONNECTION TO FAUCET. 7 SOLENOID EMERGENCY SHUT-OFF VALVE ABOVE ACCESSIBLE CEILING FOR EXHAUST HOOD FIRE SUPPRESSION SYSTEM. 8 EXTEND 1/2" HOT AND COLD WATER DOWN IN THE WALL TO THE MOP SINK. 9 THERMOSTATIC MIXING VALVE ABOVE CEILING. 10 ROUTE REFRIGERANT LINES TO REMOTE CONDENSERS AS REQUIRED. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 11 12 19 BUNDLED DRINK SYSTEM THRU WALL. VERIFY EXACT ROUTING. ROUTE LINES THRU WALL TO SERVE DRINK SYSTEM. 20 ROUTE 1 1/4" GAS LINE DOWN IN WALL, STUB THRU WALL, AND VALVE AT 12" A.F.F. FOR GAS FRYER. 21 EXTEND AND CONNECT NEW 1" DOMESITC WATER LINE INTO EXISTING 1" DOMESTIC COLD WATER (METER IN VAULT). INSTALL NEW BACKFLOW PREVENTER IN VAULT AS REQUIRED BY LOCAL WATER CO. 1 1/4" GAS UP TO RTU THRU CURB BASE. INSTALL DIRT LEG, GAS COCK, AND UNION AT UNIT CONNECTION. 22 ROUTE NEW 1" DOMESTIC COLD WATER BELOW SLAB AND RISE UP AS SHOWN. 1/2" TEMPERED AND COLD WATER LINES DOWN IN WALL TO LAVATORY. 23 PROVIDE INLINE HOT WATER RECIRCULATION PUMP AND CHECK VALVE. REFER TO SHEET P3.0 FOR DETAILED PIPING SCHEMATIC. 1/4"=1'-0" 311465 / 434385 STORE NUMBER: 1 WATER AND GAS PLAN 09.21.15 A 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 DBR 37 WATER AND GAS PLAN P3.0 KEY NOTES B PLOT DATE: 1 1 INSIDE WALL 1 FD 1 FS 15'-8" 26'-10" 19'-1121" FS FD 39'-221" 36'-6" 1 1 1 HD 1 1 FS S 28'-221" 1 S 20'-221" 21'-221" 1 L 16'-2" 15'-3" FD 1 FD 1 13'-8" 1 FS FD 13'-121" 1 11'-5" 9'-8" S WC 2 1 FS 4'-4" 7'-1121" S INSIDE WALL 1 L WC 1 N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 INSIDE WALL INSIDE WALL G FS 1 FD 1 S 1 G 1'-1" 5'-0" 5'-0" 1 S 2 FS FS 1 1 L 1 WC 1 FD 1 L 1 FD 1 WC 1 1 FD 1 6'-9" 9'-721" HD FD FS 1 FS 1 11'-621" 13'-821" 14'-5" 15'-8" 17'-421" 18'-521" 22'-721" 24'-1121" 27'-521" CONTRACT DATE: 09.21.15 BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: PLUMBING ROUGH-IN PLAN EQUIP # EQUIPMENT ITEM TYPE ELEVATION REMARKS EQUIP # EQUIPMENT ITEM TYPE ELEVATION FS 1 FLOOR SINK -- S 4 SERVICE SINK CW/HW +9" A.F.F. -- FS 2 FLOOR SINK -- S 4 SERVICE SINK W +19" A.F.F. -- FD 1 FLOOR DRAIN -- S 5 BAR SINK CW/HW +3" A.F.F. -- HD 1 HUB DRAIN -- WH 1 WATER HEATER CW WH 1 WATER HEATER G WC 1 WATER CLOSET FLUSH TANK WC 2 WC COLD WATER GAS B. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE THIS DATA ON THE LOCATION OF ALL PLUMBING ROUGH-INS WITH INFORMATION PROVIDED ON THE ARCHITECTURAL AND THE STRUCTURAL DRAWINGS AND THE EQUIPMENT ACTUALLY SUPPLIED AND TO CONFIRM THE CORRECTNESS OF ANY DIMENSIONS INDICATED HEREIN. FLOOR DRAIN 1 TEMPERED WATER G -- C-919 TRIPLE FRYER G +12" A.F.F. +15" A.F.F. -- C-924 PIZZA OVEN (TRIPLE DECK) G +10" A.F.F. CW +10" A.F.F -- N-100 GLASS WASHER HW +8" A.F.F. INSTALL PER MANUF. INSTRUCTIONS WATER CLOSET FLUSH TANK CW +10" A.F.F -- N-100 GLASS WASHER W +16" A.F.F. INSTALL PER MANUF. INSTRUCTIONS 3 WATER CLOSET FLUSH TANK CW +8" A.F.F -- S-570 CARBONATOR FW +36" A.F.F. VALVE BELOW COUNTER UR 1 URINAL FLUSH VALVE CW +40" A.F.F. WALL MOUNTED S-590 WATER FILTER SYSTEM CW +94" A.F.F. INLET TO & OUTLET FROM FILTER UR 1 URINAL WASTE STUB W +9-1/2" A.F.F. WALL MOUNTED S-906 DRINK DISPENSER FW - VIA SYRUP BUNDLE L 1 LAVATORY TW +20" A.F.F. -- S-907 COFFEE BREWER FW +12" A.F.F. AND ICE TEA BREWER S-928 L 1 LAVATORY WASTE LINE W +16-1/2" A.F.F. -- S-928 ICE TEA BREWER FW +36" A.F.F. VALVE BELOW COUNTER S 1 HAND SINK TW +18" A.F.F RIM OF LAV @ +2'-8" A.F.F. S-936 HOT HOLDING CABINET FW +78" A.F.F. S 2 MOP SINK FAUCET CW/HW +36" A.F.F -- S-937 HOT HOLDING CABINET FW +78" A.F.F. S 3 3-COMPARTMENT SINK FAUCET CW/HW +38" A.F.F -- S-957 BAR GUN DRINK DISPENSER SYSTEM FW - A A. ALL DIMENSIONS TO FLOOR SINKS, FLOOR DRAINS, AND HUB DRAINS ARE TO CENTER OF FIXTURE. HOT WATER REMARKS 1/4"=1'-0" 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 VERIFY ROUGH-IN IN HEIGHTS WITH FIXTURE PROVIDED. RIM SHALL BE NO HIGHER THAN 17" AFF AND FLUSH VALVE HANDLE SHALL BE 44" AFF MAX. DIMENSION. FLOOR SINK DBR 37 HUB DRAIN WASTE OUTLET UNDERGROUND PLMB. ROUGH-IN FLOOR CLEANOUT WALL CLEANOUT FILTERED WATER VIA SYRUP BUNDLE P4.0 VENT UP FROM UNDER SLAB WATER LINE THRU FLOOR. PLUMBING ROUGH-IN SCHEDULE D SYMBOL LEGEND C PLUMBING ROUGH-IN NOTES B PLOT DATE: ECO 1 2-WAY CO N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F MV S MV 1 4" SANITARY SEWER TO SITE SANITARY MAIN 1 1 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 4" WASTE TO 1000 GALLON EXTERIOR GREASE INTERCEPTOR S MV RP 1 1/2" 1 1 ECO 1 2-WAY CO MV 1 2" HS 1 SS 4" HW WH WH R 1 1 S 1 1/2" 5 MV 4 S S MV HW R FS 4" 3" VENT TO 1000 GALLON EXTERIOR GREASE INTERCEPTOR 1 1 1 2" 2" GW 4" 4" 3" HS 4" 2" 3"VTR 1 1/2" SS 3"VTR R HW MV 1 ROUTE BELOW SLAB TO SODA CABINET 1 LAV 2" SODA WC 1 1/2" 2" ROUTE BELOW SLAB TO BAR CW TW DM 1 WC 4" FS 2" 4" 2" 2" 2" 4" FD FCO LAV 4" 3" FS 4" WCO 3" WC S S MV 1 1 3 S S HS 4" SS 1 1 SS 3" FD 2" 4" GW 2" 4" WC L 2" FD 4" 2" 1 1/2" CW MV 2" 3" FD 3" 1 4" HD 4 1 FS 4" FS WATER ISOMETRIC N.T.S. 4 FD GW 3" 4" 4" FCO WASTE AND VENT ISOMETRIC N.T.S. 1 GAS DEMAND SCHEDULE RTU-1 250 MBH RTU-2 200 MBH WH-1 (2 @ 199 MBH EA) 398 MBH PIZZA OVEN (3 @ 150 MBH EA) 450 MBH FRYER (2 @ 80 MBH EA.) 160 MBH TOTAL DEMAND 1458 MBH =1,458,000 BTUH PLUMBING CONTRACTOR SHALL VERIFY THE GAS PRESSURE AT EACH APPLIANCE BEFORE TURNOVER. PIPE SIZED BASED ON 7" W.C. DELIVERY PRESSURE AND 0.5" W.C. PRESSURE DROP PER INTERNATIONAL FUEL GAS CODE TABLE 402.1(1). NEW GAS METER LOCATED APPROXIMATELY 150' AWAY ON LONGEST RUN. CONTRACT DATE: RTU DBR 37 PLAN VERSION: 009.00.00 311465 / 434385 STORE NUMBER: NOT USED N.T.S. 2 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 2-1/2"G ABOVE CEILING FRYERS BUILDING TYPE: SITE NUMBER: EMERGENCY GAS SHUT-OFF 1 09.21.15 EMERGENCY GAS SHUT-OFF RISE UP IN WALL TO GAS METER, BY LOCAL UTILITY. DIRT LEG (TYPICAL) WH WH 1 1 PIZZA OVEN DBR 37 1-1/4" (TYP) RISER DIAGRAMS RTU 2 P5.0 GAS ISOMETRIC N.T.S. 5 NOT USED 3 PLOT DATE: 1/2" CW EDGE OF WALL TRAP PRIMER VALVE 2" GAS IN WALL CONNECTION TO DRAIN PAN FULL SIZE VENT TO ATMOSPHERE 1/2" CW TO FIXTURE 2" FULL PORT GAS BALL VALVE W/ LEVER HANDLE (EQUAL TO NIBCO FP-600) 2" GAS DOWN IN WALL N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F RTU EQUIPMENT CURB 2"x1-1/4" BELL REDUCER 1-1/4" FLEX HOSE TO OVENS REVISIONS DATE APPRVD. Unit 1 Unit 2 RETURN CONDENSATE DRAIN LINE THROUGH CURB, CONNECT TO MAIN ABOVE CEILING AND TERMINATE 2" ABOVE RIM OF MOP SINK. INSULATE ALL PIPING BEYOND THIS PENETRATION Notes: 1. Size the pump to provide at least 2 GPM through the system at 10 ft of head plus piping losses. System Controller (*4) 2. Pump Control Signal is Noritz's preferred method to control the recirculation pump. For pumps larger than 85W, relay connection should be used. If Noritz pump control is not used, an aquastat may be be used to control pump. N UP PRIORTY BURNER Power gal. ON/OFF DOWN -Please read instructions carefully before using this appliance. WARNING -Check actual and controller water temperature before entering shower or bath. FLOW METER ALARM SET burns instantly or death from scalding. RC-7646M-1 FLOOR FLOOR SIDE ELEVATION FRONT ELEVATION CONTRACTOR SHALL MAKE CONNECTION TO OVENS PER MANUFACTURER'S RECOMMENDATIONS DEEP SEAL P-TRAP W/ TRAP PRIMER CONNECTION SEE WASTE PLAN FOR CONDENSATE LINE BELOW ROOF 5. When connecting 2 devices, use only a single remote controller. 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 DIRT LEG 1/2" CW REMOVABLE THREADED CAP FOR CLEAN-OUT & WINTER DRAINING 4. System Controller can be used to connect a 2 or more unit multisystem application. When System Controller is in use, pump control and tub alarm features are disabled. Refer to SC-201-6M manual for detailed instructions in setting up system controller. NORITZ 2" GAS THRU WALL W/ ESCUTCHEON WALL DIRT LEG FLOOR DRAIN NOTE: PROVIDE TRAP PRIMERS FOR DRAINS AS REQUIRED BY LOCAL AUTHORITIES OR CODE. 3. If system controller isn't controlling pump, an aquastat may be used. Wire aquastat to pump according to "Circulation Pump to Aquastat Wire Diagram (PAWD.pdf)." Remote Controller (*5) 12"X12" S/S ACCESS PANEL IN WALL OR CEILING IF REQUIRED 18" DESCRIPTION CLOSE NIPPLE CONNECTOR (TYP) HANDLE IN CLOSED POSITION YMS003 REV. 6. Size the piping to allow for the maximum flow rates of the units. Isolator Kit (*7) RTU CONDENSATE 7. Noritz recommends the use of Isolator Kit (IK-WV-6) with installation. Connections are available in Threaded, Sweat, or Push-On. These kits include an integrated shut-off and service valve with unions and a pressure relief valve. Expansion Tank (Install according to local code) 13 TRAP PRIMER (AS REQ. BY CODE) N.T.S. 9 OVEN GAS CONNECTION Hot Water Return Aquastat (*3) Pump (*1) Pump Control Signal (*2) FILTER LINE F1 SUPPLIES _______________________ SHUT-OFF VALVE (TYP) 1. CARBONATORS 2. DRINK DISPENSERS THERMOMETER 8-10 Gallon Storage Tank (To alleviate cold water sandwich) MV MF5/600 Noritz Accessories 11160 Grace Avenue Fountain Valley, California 92708 866-7NORITZ (866-766-7489) www.noritz.com DRAWING NUMBER: (2a2)N132M DRAWING DATE: December 19, 2007 Power gal. ON/OFF DOWN RC-CORD10 (10' Remote Controller Cord, optional in 26') VC-132M (Outdoor Vent Cap, place on top of unit) SC-201-6M (System Controller, for 2 or more unit Multi-System) Shut-off Ball Valve Aquastat (Honeywell Model #L6006A or L6006C) Check Valve Pump F1 1 1/2" LINE Union Mixing Valve Pressure Relief Valve (Watts 174A, Zurn P3000BR, Cash Acme F-82) Thermal Expansion Tank DOMESTIC CW YMF002 NORITZ BURNER 2 DOMESTIC HW WATER HEATERS N.T.S. 1 8 KEY NOTES: 1 3/4" COLD WATER INLET TO 1/2" COPPER LINE AND FITTINGS AT FILTER. 2 3/4" F2 OUTLET W/ INTEGRAL BACKFLOW PREVENTER, EQUAL TO WATTS REGULATOR CO. SERIES 007 AND SERVICE BALL VALVE. TEMPERING VALVE 3" PVC EXHAUST DUCT MANUFACTURER WALL WATER HEATER 1/2" SWEAT/ 3/8" COMPRESSION 1/2" VINYL OR PVC CONDENSATE DRAIN. MUST INCLUDE LOOP AIR TRAP. 1/4"/ FT MIN. SLOPE 3" 5. 6. 7. 6 FACE OF SINK NOTE: 1/2" PIPING SHALL BE HARD COPPER LINE, OR BRAIDED STAINLESS HOSE. SOFT COPPER IS NOT ACCEPTABLE. 1. 2. 3. 4. N.T.S. GENERAL NOTES: 1/2" COPPER LINE FROM MIXING VALVE ABOVE OVERALL DIMENSIONS 21-0" WIDE x 8" DEEP x 18" HIGH SEE SCOPE OF WORK FOR ADDITIONAL INFORMATION. SEE SHT. A2.0 FOR LOCATION. INSTALLATION MUST COMPLY WITH STATE OR LOCAL PLUMBING CODES. THE UNIT MUST BE PROTECTED AGAINST FREEZING. USE ONLY TEFLON (HIGH-LOW TEMPERATURE) TAPE TO SEAL THREADED PARTS; NO PIPE DOPE. DO NOT INSTALL WHERE LINE PRESSURE EXCEEDS 125 PSI OR WHERE TEMPERATURE EXCEEDS 100 F. 1/2" SWEAT W/ 1/2" MALE ADAPTER WATER HEATER PLATFORM 1/2" ANGLE STOP VALVE TOP OF LOOP MUST BE BELOW BOTTOM OF EXHAUST ELBOW. 1/2" HARD COPPER LINE TO SINK 1/2" WALL STRAP HUB DRAIN/FLOOR SINK NOT TO EXCEED 1" A.F.F. 1/2" SWEAT ELBOW CONTRACT DATE: SINGLE FOOT PEDAL 1/4" X 3" TAPCON HEX HEAD SCREW 1/2" SWEAT W/ 1/2" MALE ADAPTER YMF001 UP PRIORTY Note: This diagram is for reference only. Installation must comply with State and Local Code, all gas and water pipe must be sized correctly to specific length, according to accepted RC-7646M-2 (Remote Controller) engineering methods or the UPC Code for Noritz Water Heaters to operate correctly. KMW001 NORITZ CARBON N PARTICULATE N-132M Domestic Hot Water 2 Unit Multi-System Recirculation 1 CHECK VALVE (TYP) Fixtures APPLICATION: 5 HIGH FLOW WATER FILTRATION SYSTEM Hot Water (*6) MODEL: N.T.S. 1/2" TEMPERED WATER TO LAVATORIES Cold Water Supply Gas Supply Relay for Pump (If over 85 Watts) N.T.S. 09.21.15 BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: 19 15 WATER FILTER SYSTEM N.T.S. 11 FOOT PEDAL N.T.S. 7 WATER HEATER CONDENSATE DETAIL N.T.S. 3 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 PRESS. RELIEF VALVE (PIPE TO F.S.) 2X4 WALL BOOSTER HEATER SHOCKSTOP LAVATORY UNION (TYP) HW TO DISHWASHER DBR 37 FLOOR MOUNT UPRIGHT SUPPORT PRESSURE/TEMPERATURE GAUGE (TYP OF 2) 4x4 WELDED BASE PLATE W/ (4) 1/2" HILTI KWIK BOLT II OR EQUAL BLENDED PHOSPHATE WATER TREATMENT SYSTEM (INSTALL IN ACCESSIBLE LOCATION) PRESSURE REDUCING VALVE FINISH FLOOR P6.0 BALL VALVE 3/4"HW 20 16 12 LAVATORY SUPPORT PLUMBING DETAILS N.T.S. 8 BOOSTER HEATER PIPING DETAIL N.T.S. 4 PLOT DATE: GREASE TRAP MODEL No. GT-1000 N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 30" 24" GRADE CAST IRON FRAME AND COVER 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 6" PVC DOUBLE TEE MANIFOLD SPECIFICATIONS CONCRETE : 4500 PSI AT 28 DAYS. UNIT IS OF MONOLITHIC SEWER SEWER W 30" VARIES INLET OUTLET SECTIONAL RISER RCP PIPE JOINT SEALED w/ NONSHRINK GROUT REINFORCEMENT: INLET AND OUTLET PIPING PROVIDED BY OTHERS. C.I. CASTINGS: 24" DIAMETER AND BE TRAFFIC DUTY. NOTES 2. INLET 3. USE 24" T&G R.C.P. FOR INSTALLATION GREATER THAN 6'-0" DEEP. (STD RING AND M.H. COVER REQUIRED) 4. SAMPLING WELL MUST BE SET IN A CIRCULAR OR SQUARE CONCRETE PAD ( 1'-0" GREATER THAN OUTSIDE DIAMETER OF PIPE.) 18" OUTLET FRONT VIEW TO BE INSTALLED ON PRIVATE PROPERTY, IN AN ACCESSIBLE LOCATION TO CITY PERSONNEL. USE 15" T&G R.C.P. FOR INSTALLATION FOR INSTALLATION 6'-0" DEEP AND LESS. 5. INSIDE INSTALLATION NOT PERMITTED, WHERE OUTSIDE INSTALLATION IS POSSIBLE. 6. INSTALLATION INSIDE BLDG MUST BE POURED IN PLACE (15"MIN) NO CONCRETE PIPE IS PERMITTED, (AIR-TIGHT COVER REQUIRED.) 7. LAWN INSTALLATION MUST BE 4" ABOVE FINISHED GRADE. 8. DRIVE & SIDEWALK INSTALLATION MUST BE BROUGHT TO FINISHED GRADE GRADE GRADE VENT 1. 6" VENT SLEEVE LIQUID SURFACE MONOLITHIC BAFFLE H GRADE SPECIFICATIONS CONCRETE : CLASS 1 CONCRETE WITH OF DESIGN STRENGTH OF 4500 PSI AT 28 DAYS. UNIT IS OF MONOLITHIC CONSTRUCTION AT FLOOR AND FIRST STAGE OF WALL WITH SECTIONAL RISER TO REQUIRED DEPTH. C.I. CASTINGS: CAST IRON FRAMES AND GRATES ARE MANUFACTURED OF GREY CAST IRON CONFORMING TO ASTM A48-76 CLASS 30, HEAVY-DUTY AASHTO H-20 REVERSIBLE CONFIGURATION 6" PVC DOUBLE TEE MANIFOLD FL2 NOTE: GALVANIZED RISER SUPPORT (TYPICAL) SAMPLING WELL SHALL BE EQUIVALENT TO: PARKS EQUIPMENT SERVICES SAMPLE WELL SWB-1; HANSON PRE-CAST PRODUCTS TEST WELL; PW EAGLE SAMPLE WALL. SAMPLE WELLS WILL HAVE A 15" DIAMETER ACCESS COVER AND FLOW FROM INLET TO OUTLET PIPING THROUGH SAMPLING WELL. PRECAST CONCRETE INTERCEPTOR FL1 L 1000 GALLON GREASE INTERCEPTOR DETAILS GENERAL NOTES: SYRUP LINES, WATER LINES FOR THE CARBONATOR PUMPS, ICO2 LINE FOR PNEUMATIC GATE AND PLAIN WATER FOR THE DISPENSERS ARE RUN INSIDE THE TUBING BUNDLE. 1/4" CO2 LINE TO PNEUMATIC GATE REGULATOR (LOCATED BEHIND DISPENSER FRONT PANEL). PRESSURE PRESET TO 30-35 MAX PSI. 3/8 LINES TO DISPENSERS 3/8 LINES TO ICEMAKER 1. OVERALL FILTER DIMENSIONS: 25-1/2" WIDE x 9" DEEP x 32" HIGH 2. SEE 2/ V2.0 AND THE SCOPE OF WORK FOR SCOPE DEFINITIONS. 3. ROUGH-INS SHALL BE PROVIDED BY THE CONTRACTOR. 4. INSTALLATION MUST COMPLY WITH ANY STATE OR LOCAL PLUMBING CODES. 5. THE FILTER MUST BE PROTECTED AGAINST FREEZING. 6. USE ONLY TEFLON (HIGH-LOW TEMPERATURE) TAPE TO SEAL THREADED PARTS; NO PIPE DOPE. 7. DO NOT INSTALL WHERE LINE PRESSURE EXCEEDS 125 PSI OR WHERE TEMPERATURE EXCEEDS 100 F. 1/2 I.D. LINE WATER REGULATOR - 60PSI UNFILTERED BOOSTER TANK PRESSURE SWITCH/ RELIEF VALVE DOUBLE CHECK VALVE REGULATOR WATER PRSSURE GAGE 60PSIG PRESSURE SETTING PUMP 100GPH DRINK COUNTER 1/2" LINE WATER FILTER FILTERED SURGE TANK DRINK COUNTER SHUT-OFF VALVE 3/8 BARB FITTINGS ON INLET AND OUTLET 1/2 LINE CO2 SECONDARY REGULATOR MT DEW CODE RED 55-60 PSI SIERRA MIST PRE-SET CO2 REGULATOR PRE-SET CO2 REGULATOR REGULATOR PEPSI PEPSI MOUNTAIN DEW DISPENSER DRAIN DISPENSER DRAIN OPEN OPTIONAL DR. PEPPER 8. CONTRACT DATE: SEE THE EQUIPMENT PLAN FOR LOCATION. SEE 8/ V2.0 FOR BUNDLE DETAILS 9. "Y" FOR ICE MACHINES SUPPLY LINES 10. SHALL BE INSTALLED @ FILTER OUTLET. CO2 SECONDARY REGULATOR 90-100 PSI BULK CO2 TANK 3 RECEPT. 115/60/1 20 AMPS EA. 3 11. BACKFLOW PREVENTERS FOR FILTER ASSEMBLY ARE PROVIDED. BACK ROOM WAIT STATION WITHIN 4" CHASE. WITHIN 4" CHASE. 009.00.00 311465 / 434385 2015388.14 12. COORDINATE AND VERIFY ALL WORK WITH VENDOR FOR DRINK SYSTEMS 123 Minden Shopping Dr. Minden, LA 71055 STRAPPED OR SECURED TO THE WALL DIET PEPSI LIPTON BRISK DBR 37 SWITCH-OVER VALVE TYPICAL SYRUP LINE (ONLY 1 SHOWN FOR CLARITY) FLOOR SINK PLAN VERSION: PIZZA HUT NOTE INSTALL ELECTRICAL, WATER, AND DRAIN IN ACCORDANCE WITH ALL LOCAL, STATE & FEDERAL CODES. EQUIPMENT RATING: ED300 DISPENSER - 115V, 5.2 AMPS ED250 DISPENSER - 115V, 3.5 AMPS CARBONATOR - 115V, 60 Hz, 7.0 AMPS BOOSTER ASSEMBLY - 115V. 60 Hz, 6.5 AMPS PEPSI PLATFORM LEGEND Nxxx FLOW ARROW KITCHEN EQPT NO. (SHT A2.1) PPS005 BAR DISPENSER DRAIN DBR 37 STORE NUMBER: FINISHED FLOOR FLOOR SINK BUILDING TYPE: SITE NUMBER: CARBONATOR DISPENSER DRAIN 09.21.15 POINT OF CONNECTION (PEPSI) SYSTEM POINT OF CONNECTION (GC) DRINK SYSTEM SCHEMATIC N.T.S. 2 WATER FILTRATION SCHEMATIC N.T.S. 4 P7.0 PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 R8 D EF 2 B-21 WP GFI B-37 P12 WH R2 1 B-21 A-27 WP GFI SD CO V F P17 P18 SYMBOL LIST P11 POWER PLAN NOT USED. P11 J-BOX FOR SIGNAGE. COORDINATE LOCATION WITH SIGNAGE VENDOR. SEE SCOPE OF WORK. P2 NOT USED. P12 PROVIDE A 20-AMP, 1-POLE DISCONNECT SWITCH AND 120V ,1P/20 AMP CIRCUIT TO INSTANTANEOUS WATER HEATER CONTROLS. VERIFY POINT OF CONNECTION. P3 PROVIDE 20A., 120V., DUPLEX ISOLATED GROUND RECEPTACLE FOR DEMARK TELEPHONE TERMINAL BOARD. P13 INSTALL CONTROL CABLE FROM FREEZER/COOLER FAN COIL TO ROOF MOUNTED CONDENSER. P4 NOT USED. P14 P5 DISHWASHER - 60A., 3P., 240V., MANUAL MOTOR STARTER SWITCH WITH STAINLESS STEEL LOCKOUT AND TAGOUT COVER PLATE. PROOFER - 20A., 2P., 240V., CEILING MOUNTED L6-20R TWIST LOCK RECEPTACLE AND STAINLESS STEEL COVER PLATE. OVENS - 20A., 1P., 120V., MANUAL MOTOR STARTING SWITCH WITHOUT OVERLOADS WITH STAINLESS STEEL LOCKOUT AND TAG OUT COVER PLATE. PROVIDE FLEX CONNECTION FROM MANUAL MOTOR STARTERS TO OVEN DECKS (TYP.). REFER TO ARCHITECTURAL DETAIL IF OVENS ARE PROVIDED WITH FACTORY CORD AND PLUG SETS, PROVIDE PLUG WITH MATCHING CONFIGURATION. P18 P7 J G P1 P6 J P8 NOT USED. P9 DEDICATED CIRCUIT FOR SECURITY SYSTEM POWER. PROVIDE LOCK-ON CLIP AT CIRCUIT BREAKER. P10 ALL EXTERIOR LIGHTING AND SIGNAGE SHALL BE CIRCUITED THROUGH EXTERIOR LIGHTING CONTACTOR/PHOTOCELL CONTROL PANEL. SEE DETAIL 8 ON SHEET E6.0 FOR ADDITIONAL INFORMATION. A SPECIFIED TRANE RTU IS SUPPLIED WITH THRU THE BASE ELECTRICAL CONNECTIONS AND FACTORY INSTALLED HACR CIRCUIT BREAKER WITH WEATHER TIGHT ENCLOSURES AND ACCESS THRU SWINGING DOOR. CONTRACT DATE: R2 POWER AND CONTROL ENTRY FROM BOTTOM OF UNIT. BUILDING TYPE: DBR 37 NOT USED. R3 CONNECT TO CONTACTOR LC. SEE LIGHTING CONTROL RELAY REAR. SHEET E6.0. PLAN VERSION: 009.00.00 P15 NOT USED. R4 1/2" C, WITH REQ'D CONDUCTORS TO J-BOX IN CEILING ABOVE ICE MACHINE. MAKE CONNECTION TO ICE MACHINE AND CONDENSING UNIT ON ROOF. SITE NUMBER: P16 NOT USED. R5 COOLER / FREEZER CONDENSING UNIT ON ROOF. SEE ARCH. P17 POWER SUPPLY BOX FOR CANOPY LIGHTING. VERIFY WITH CANOPY MANUFACTURER FOR EXACT REQUIREMENTS. SEE SCOPE OF WORK. J-BOX FOR CANOPY LIGHTING. MOUNT INSIDE OF CANOPY. VERIFY EXACT LOCATION IN FIELD. P19 R6 R7 NOT USED C R9 A. NO CONDUIT SHALL BE FASTENED DIRECTLY TO OR THROUGH ROOFING MEMBRANE. B. ALL CUTS IN ROOFING MEMBRANE SHALL BE MINIMAL AND IN ACCORDANCE WITH ROOFING MFR'S AND INSTALLER'S REQ'S. E K. PER SECTION 210.8(B)(3) NEC 2011, ALL 15 AND 20A, 120V RECEPTACLES IN COMMERCIAL KITCHENS REQUIRED TO BE GFCI PROTECTED AND READILY ACCESSIBLE, IF DEVICE IS NOT READILY ACCESSIBLE A GFCI PROTECTED BREAKER OR DEADFRONT DEVICE SHALL BE PROVIDED. L. ALL CONNECTIONS AND ELECTRICAL EQUIPMENT LISTED IN SCHEDULE SHALL BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. FIELD VERIFY CONNECTION REQUIREMENTS AND EQUIPMENT PROVIDED BY OTHERS PRIOR TO ROUGH-IN. M. REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS FOR THE REQUIREMENTS ASSOCIATED WITH WIRING AND CONNECTIONS OF INTERLOCKING, THERMOSTAT LOCATIONS, EXHAUST FAN CONTROL SWITCHES, AND OTHER CONTROLS OF MECHANICAL EQUIPMENT. N. PROVIDE DUCT MOUNTED SMOKE DETECTORS IN THE SUPPLY DUCT. VERIFY THE REQUIRED QUANTITY OF DUCT SMOKE DETECTORS FOR EACH UNIT WITH DUCTWORK LAYOUT TO MEET NFPA REQUIREMENTS. R8 MOUNT PHOTOCELL ON NORTH SIDE OF RTU-1. CONNECT TO EXTERIOR LIGHTING 311465 / 434385 2015388.14 PIZZA HUT RTU'S SHALL BE PROVIDED WITH BUILT-IN FUSED DISCONNECT, SINGLE POINT WIRING AND CONVENIENCE OUTLET. OUTLET TO BE WIRED SEPARATE FROM RTU. CIRCUIT AS SHOWN. EXHAUST FANS SHALL BE PROVIDED WITH A WEATHERPROOF DISCONNECT SWITCH, SINGLE POINT WIRING. 123 Minden Shopping Dr. Minden, LA 71055 PROVIDE CONNECTION FROM RETURN AIR DUCT SMOKE DETECTORS TO MECHANICAL CONTROL CIRCUIT PER DETAIL 2/E6.0, AND FIRE ALARM SYSTEM (IF PRESENT). PROVIDE A RELAY TO SHUT DOWN HVAC EQUIPMENT UPON ACTIVATION OF DUCT DETECTOR OR FIRE ALARM SYSTEM (IF PRESENT). C. REFER TO MECH DWGS FOR MECHANICAL EQUIPMENT ELECTRICAL REQ'S. DBR 37 D. ALL EXPOSED ELECTRICAL CONDUITS SHALL PENETRATE ROOF E. MEMBRANE AT PIPE HOODS U.O.N. F. REFER TO ELECT EQUIP SCHEDULE AND ELECT ROUGH-IN PLAN. G. ALL CONDUITS FROM EXHAUST FANS SHALL BE ROUTED INSIDE OF CURB. POWER/ ROOF PLAN H. ALL CONDUITS TO AND FROM RTU SHALL BE ROUTED INSIDE OF RTU CURB. COORDINATE WITH RTU MFR RECOMMENDATIONS. I. REFER TO GENERAL NOTES SHEET E1.0 FOR IMPORTANT INFORMATION. E2.0 J. ALL WIRING AND CONDUITS SHALL BE CONCEALED. NO CONDUITS PERMITTED TO RUN EXPOSED ACROSS ROOF DECK. ROUTE ALL CONDUITS THROUGH EQUIPMENT ROOF CURBS OR SRHCITECT SPECIFIED ROOF PENETRATIONS. POWER PLAN GENERAL NOTES 09.21.15 STORE NUMBER: CONTROL PANEL. LIGHTING CONTROL PANEL SHALL BE PROVIDED BY OWNER, AND INSTALLED BY ELECTRICAL CONTRACTOR. CONTROL PANEL SHALL BE RECESSED DIRECTLY BELOW ELECTRICAL PANEL "C". COORDINATE WITH OWNER PRIOR TO ANY ROUGH-IN WORK. SEE DETAIL 8 ON SHEET E6.0 FOR ADDITIONAL CONTROL PANEL INFORMATION. POWER KEY NOTES A. ALL RECEPTACLES SHALL BE INSTALLED 18" AFF UNLESS NOTED OTHERWISE. B. ALL CONDUIT DROPS ARE INSIDE WALLS U.O.N. SEE ARCH DWGS FOR WALL DIMS. C. ALL J-BOX CIRCUITS, CONDUITS, FIXTURES, ETC SHALL BE AS INDICATED ON THE ELECT DWGS AND SPECS. D. CONTRACTOR TO VERIFY UNDERGROUND CONDUIT LOCATIONS PRIOR TO POURING SLAB. E. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE THIS DATA ON THE LOCATION OF ELECT ROUGH-INS WITH INFO PROVIDED ON THE ARCH AND STRUCT DWGS AND THE EQUIPMENT ACTUALLY SUPPLIED, AND TO CONFIRM THE CORRECTNESS OF ANY DIMENSIONS HEREIN. F. LOCATIONS OF ALL OUTLETS MAY BE RELOCATED TO NEAREST STUD. DO NOT CUT INTO STUDS. G. FOR EXACT LOCATIONS OF KITCHEN & MECHANICAL EQUIPMENT AND POINTS OF CONNECTION, REFER TO KITCHEN & MECHANICAL EQUIPMENT DRAWINGS AND MANUFACTURER'S SHOP DRAWINGS. H. ALL CIRCUIT FEEDERS AND DISCONNECTS SHALL BE SIZED BY NEC. I. CONTRACTOR SHALL VERIFY CIRCUIT BREAKER, DISCONNECT SWITCH, STARTER AND FUSE SIZES WITH SELECTED EQUIPMENT MANUFACTURER'S SHOP DRAWINGS PRIOR TO PLACING ORDER AND PROVIDE EVERYTHING AS REQUIRED. J. ELECTRICAL EQUIPMENT ENCLOSURES SHALL BE NEMA-1 FOR INTERIOR AND NEMA 3R FOR EXTERIOR. IN COASTAL REGIONS THE STANDARD FOR OUTSIDE SHALL BE NEMA-4X. R1 1/4"=1'-0" F POWER ROOF PLAN NOTES D POWER ROOF PLAN KEY NOTES B PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 2 G B-22 PANEL "A" G B-22 G B-22 GE B-22 8 G B-22 G B-22 G B-22 G B-22 G B-22 PANEL "B" G B-22 RH K 7 B-25 B-17 8 G B-22 10 B-20 8 GE B-22 #1 #2 A-14 5 G B-22 A-14 4 E B-33 E B-33 E B-33 E B-33 E B-33 E B-33 E B-33 E B-33 E B-33 E B-33 12 B-27 11 E B-20 6 E B-33 E B-20 E B-20 EM LB LB LB LB 3 LB LB LB LB LB LB LB LB B-9 E B-20 EM B-25 E B-33 9 3 6 1 E B-20 K 12 B-27 8 LB E B-33 EM 11 A B-29 K A B-29 A B-29 A B-29 A B-29 A B-29 RH LB B-25 LB B-25 RH B-39 9 B-9 9 LIGHTING PLAN NO. A QUANTITY 7 E 26 EM 5 K 2 LB 33 LOCATION MANUFACTURER / CATALOG NUMBER DINING ACCUSERV/ BES00298-105 DINING ACCUSERV/ 0039-017/ CT6FB/ RC6-GU24 DINING KITCHEN KITCHEN DINING DINING LITHONIA / ELM4 DESCRIPTION CORD HUNG PENDANT ELECTRONIC RECESSED COMPACT FLUORESCENT DOWNLIGHT EMERGENCY LIGHT LITHONIA/ LQM SW3 R 120/277 ELN LED EXIT LIGHTOLIER/ LT-J-08-RWF-827-BK MINI CYLINDER TRACK HEAD LAMP # 1 1 2 - 1 TYPE MOUNTING GU24 LED PENDANT - RECESSED N1212 HEADS W/ FIXT. SUPPLIED W/ FIXTURE LED WALL CEILING TRACK MT. VOLT WATT 120 10 120 120 25 120 3 120 9 2 DINING JUNO/ T4BL 4' BLACK TRACK SECTION REFER TO LIGHT FIXTURE SCHEDULE NOTE #3. LB8 7 DINING JUNO/ T8BL 8' BLACK TRACK SECTION REFER TO LIGHT FIXTURE SCHEDULE NOTE #3. EXTERIOR ACCUSERV #B9354NB DECORATIVE WALL SCONCE WALL SCONCE 1-LIGHT DOWN REMOTE HEAD W1 2 W2 5 RH 3 EXTERIOR ACCUSERV #7037-42 EXTERIOR LITHONIA # ELA-T-NX-NO806 1 1 1 WALL 8W INC. WALL WALL 120 1. RED SHADE NOTE #13 LB4 L1372 HALOGEN 42 WATT CF REMARKS 18 120 46 120 16 EMERGENCY FIXTURE WITH EMERGENCY BATTERY EXIT FIXTURE W/ BATTERY SEE NOTE #2 PROVIDE TRACK AS LISTED BELOW LIGHT FIXTURES SHALL BE PROVIDED WITH ELECTRONIC BALLASTS. COMPACT FLUORESCENT ELECTRONIC BALLASTS SHALL HAVE END-OF-LIFE PROTECTION CIRCUIT TO PREVENT WELDING OF LAMPS IN SOCKETS OR LAMP BREAKAGE. SEE SPECIFICATIONS. 2. PROVIDE ARROWS AND FACES AS INDICATED ON THE DRAWINGS. 3. PROVIDE TRACK, END FEEDS, AND COUPLING DEVICES IN QUANTITIES AS REQUIRED TO FORM THE TRACK LENGTHS SHOWN. REFER TO THE PLANS FOR LOCATIONS OF TRACK. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS AND ELEVATIONS FOR EXACT LOCATIONS FOR LIGHTING FIXTURES. 4. ELECTRICAL CONTRACTOR SHALL VERIFY ALL FIXTURE LOCATIONS WITH ARCHITECTURAL ELEVATIONS. 5. ELECTRICAL CONTRACTOR SHALL INSTALL ALL CEILING MOUNTED LIGHTING FIXTURES IN LOCATIONS AS INDICATED ON THE ARCHITECTURAL REFLECTED CEILING PLAN. 6. ALL PENDANT FIXTURES ARE PROVIDED WITH FACTORY INSTALLED 12' CORD AND STRAIN RELIEF FITTINGS. CONNECTION AND CUTTING OF CORD FOR PENDANT FIXTURE MOUNTING SHALL BE ONLY AT UPPER CANOPY. 7. LIGHTING FIXTURE CONTACT: ACCUSERV EQUIPMENT & SUPPLY 3865 PRODUCE RD., SUITE #208, LOUISVILLE, KY 40218, PHONE: 877-707-7378, FAX: 502-961-0357. SURFACE MOUNT FIXTURE SURFACE MOUNT FIXTURE 8. FIELD PAINT PENDANT TRACK ADAPTER BLACK. MOUNT FIXTURES AT 58" A.F.F. TO BOTTOM. 9. CONFIRM LIGHTING FIXTURE QUANTITIES WITH SUPPLIER. 10. ALL CONDUITS ENTERING OR LEAVING COOLER SHALL BE PROVIDED WITH EYS SEAL-OFF FITTING WITH COMPOUND PER NEC 300-(7a). 11. CONTRACTOR TO FIELD VERIFY CEILING TYPE AND PROVIDE PROPER MOUNTING HARDWARD. 1/4"=1'-0" A 1 JUNCTION BOX AND ASSOCIATED 120V ,1P/20 AMP CIRCUIT MOUNTED BELOW ROOF DECK FOR CONNECTION TO EF-3 ON ROOF. REFER TO SHEET E2.0. 2 EXHAUST HOOD LIGHTS PROVIDED WITH HOOD AND INSTALLED BY E.C. 3 PROVIDE 120V ,1P/20 AMP WALL SWITCH FOR LOCAL LIGHT CONTROL. MOUNT AT 48" AFF. 4 PROVIDE 120V ,1P/20 AMP WALL SWITCH AT 48" AFF FOR CONTROL OF FRONT OF HOUSE LIGHTING. CONTRACTOR SHALL PROVIDE ENGRAVED LABEL AT EACH SWITCH IDENTIFYING USE. SEE DETAIL 18 ON SHEET E6.0 FOR ADDITIONAL INFORMATION. BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 5 PROVIDE 120V ,1P/20 AMP WALL SWITCH AT 48" AFF FOR REAR LIGHTING CONTACTOR CONTROL PANEL. SEE DETAIL 14 ON SHEET E6.0 FOR ADDITIONAL INFORMATION. SITE NUMBER: 6 LIGHTING FIXTURES AND SWITCHES FOR COOLER/FREEZER ARE PROVIDED WITH COOLER/FREEZER. FIXTURES AND SWITCHES ARE TO BE INSTALLED BY ELECTRICAL CONTRACTOR PER MANUFACTURER'S REQUIREMENTS AND N.E.C. ARTICLE 300-7. CONTRACTOR TO PROVIDE LAMPS FOR COOLER AND FREEZER FIXTURES. CONTRACT DATE: 7 PROVIDE JUNCTION BOX AND ASSOCIATED 120V ,1P/20 AMP CIRCUIT MOUNTED ABOVE CEILING FOR CONNECTION TO LIGHTING FIXTURES IN WALK IN COOLER AND FREEZER. ROUTE CIRCUIT TO PANEL INDICATED VIA LIGHTING CONTACTOR, SEE DETAIL 14/E6. 8 EMERGENCY (BATTERY PACK), EXIT LIGHTING FIXTURES AND NIGHT LIGHT FIXTURES (SHOWN HATCHED) TO BE CIRCUITED ON UNSWITCHED LEG OF CIRCUIT INDICATED. PROVIDE WITH LOCK-ON BREAKER. 9 ALL EXTERIOR LIGHTING AND SIGNAGE SHALL BE CIRCUITED THROUGH EXTERIOR LIGHTING CONTACTOR/PHOTOCELL CONTROL PANEL. SEE DETAIL 8 ON SHEET E6.0 FOR ADDITIONAL INFORMATION. 10 PROVIDE JUNCTION BOX AND ASSOCIATED 120V ,1P/20 AMP CIRCUIT MOUNTED ABOVE CEILING FOR CONNECTION TO WALK IN COOLER , FREEZER HEAT-TRACE AND DEFROST. PROVIDE SEALED FITTINGS INSIDE COOLER/FREEZER. 11 RESTROOM (DUAL-SENSOR) OCCUPANCY SENSOR AND POWER SUPPLY. E.C. TO PROVIDE JUNCTION BOX ABOVE CEILING FOR POWER SUPPLY (MOUNT IN AN ACCESIBLE LOCATION). PROVIDE "DOME" STYLE SENSOR SURFACE MOUNTED ON THE CEILING FOR THE BEST POSSIBLE COVERAGE AREA. CIRCUIT SHOWN, AHEAD OF LOCAL SWITCHING. 12 PROVIDE 1 AMP CURRENT LIMITER PER MANUFACTURER SPECIFICATION. 09.21.15 311465 / 434385 STORE NUMBER: 2015388.14 PIZZA HUT 123 Minden Shopping Dr. Minden, LA 71055 DBR 37 12. ALL INTERIOR LIGHITNG CIRCUITS TO BE WIRED THRU THE LIGHTING CONTROL RELAYS. SEE DETAILS 14 & 18/E6.0. LIGHTING PLAN & SCHEDULE 13. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR FINISH OF TRIM RING. E3.0 LIGHTING FIXTURE SCHEDULE D LIGHTING GENERAL NOTES C LIGHTING KEY NOTES B PLOT DATE: N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 1 6 7 2 3 5 52" 11 96" 84" 48" 5 60" 60" 48" 60" 5 S6 AS PANEL "A" 4 PANEL "B" 5 S6 S3 90" 90" 90" 88" 96" 96" 96" FS KP S5 90" S S S S S3 S3 CONTRACT DATE: 09.21.15 BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: TELCOM PLAN A. HOLD-UP BUTTON (MOUNT 2-1/2" BEHIND COUNTER EDGE) DOOR CONTACTOR (LINKED TO AUDIO / VISUAL ALARM) S MUSIC SYSTEM SPEAKERS "SOUND ALERT" DEVICE (CLG.) S OUTSIDE SPEAKER SECURITY STROBE J KP KEYPAD (MTD AT 48" A.F.F.) AS ALARM SIREN ABOVE CLG SUPPLY AND INSTALL OUTLETS AND CONDUIT FOR OWNER SUPPLIED AND INSTALLED CABLE AND LOW VOLTAGE WIRING (U.O.N.) TELEPHONE AND MUSIC SYSTEM WIRING SHALL BE SUPPLIED AND INSTALLED BY G.C. SEE SCOPE OF WORK SHEETS. B. SEE SHEET E2.0 FOR ELECT INFO ON POS, SECURITY SYSTEM, CCTV SYSTEM, (OFFICE) COMPUTER, DRIVE-THRU TIMER AND DRIVE-THRU COMMUNICATION SYSTEM. C. THIS PLAN INCLUDES CONDUITS AND J-BOXES FOR POS, SECURITY SYSTEM, CCTV SYSTEM, (OFFICE) COMPUTER, TELEPHONE SYSTEM, MUSIC SYSTEM, DRIVE-THRU TIMER AND DRIVE-THRU COMMUNICATION SYSTEM. CCTV OUTLET AT CLG U.O.N. J-BOX 2" x 4" J-BOX W/ 2 DATA PORTS B BUMP PAD (MOUNT AT FRONT COUNTER) FS HOOD FIRE SUPPRESSION SYSTEM PULL STATION MOTION DETECTOR (MTD AT 72" A.F.F.) DOOR CONTACTOR 2x4 J-BOX FLUSH MOUNTED @ 76" A.F.F CENTERED OVER DOOR IN WALK-IN WALL BY COOLER MANUFACTURER WITH 1/2" CONDUIT TO OUTSIDE OF COOLER NEAR KITCHEN CEILING. SECURITY SYSTEM INSTALLER TO INSTALL HOLD-UP BUTTON FACING DOWN AND RUN WIRING. A PIZZA HUT PROVIDE (1) 2" CONDUIT WITH PULL STRING FROM TELEPHONE TERMINAL BOARD 123 Minden Shopping Dr. Minden, LA 71055 TURNS. VERIFY SITE AND TELEPHONE COMPANY REQUIREMENTS PRIOR TO BIDDING PROVIDE (1) 2" CONDUIT WITH PULL STRING STUBBED UP ABOVE TO ACCESSIBLE CEILING FROM J-BOX AT COMPUTER WALL CABINET FOR DATA CABLES. PROVIDE HOLD UP BUTTON LOCATION (MOUNT 2 1/2" BEHIND COUNTER EDGE). VERIFY EXACT LOCATION AND REQUIREMENTS WITH SECURITY PROVIDER. DOOR CONTACT MOUNTED AT TOP OF JAMB. VERIFY EXACT LOCATION AND REQUIREMENTS WITH SECURITY PROVIDER. PROVIDE (1) 3/4" CONDUIT WITH PULL STRING STUBBED UP ABOVE ACCESSIBLE CEILING FROM J-BOX WITH VOICE/DATA OUTLET. HOLD UP BUTTON BY MANAGER DESK. VERIFY EXACT LOCATION AND REQUIREMENTS WITH SECURITY PROVIDER. D. PROVIDE (1) ONE (25) TWENTY-FIVE PAIR TELEPHONE CABLE, ONLY (3) THREE LINES SHALL BE ACTIVATED : LINE ONE FOR VOICE / FAX LINE TWO FOR SECURITY LINE THREE FOR COMPUTER 1/4"=1'-0" 2015388.14 4" X 4" J-BOX MTD. AT 48" AFF FOR SECURITY SYSTEM KEYPAD. PROVIDE (1) 3/4" C. & (1) 1/2" C. TO 4" X 4" J-B0X MTD. ABOVE CEILING. VERIFY EXACT LOCATION AND REQUIREMENTS WITH SECURITY PROVIDER. TELEPHONE SERVICE PER LOCAL TELEPHONE COMPANY. PROVIDE 2" C. WITH PULL WIRE TO POINT OF TELEPHONE COMPANY CONNECTION. VERIFY ALL REQUIREMENTS WITH LOCAL TELEPHONE COMPANY. ALARM SIREN ABOVE CEILING. CONNECT TO SECURITY SYSTEM. VERIFY EXACT LOCATION AND REQUIREMENTS WITH SECURITY PROVIDER. PROVIDE (1) 3/4" CONDUIT WITH PULL STRING STUBBED UP ABOVE ACCESSIBLE CEILING FROM J-BOX WITH DATA OUTLET. WALL MTD. MOTION DETECTOR AT 90" AFF. TO COVER CASH REGISTER AND SAFE. VERIFY EXACT LOCATION AND REQUIREMENTS WITH SECURITY PROVIDER. TELEPHONE TERMINAL BOARD. SECURITY CAMERA MOUNTED AS DIRECTED BY SECURITY PROVIDER. MOUNT SO THAT CAMERA COVERS CASH REGISTER AREA. VERIFY EXACT LOCATION AND REQUIREMENTS WITH SECURITY CAMERA PROVIDER. E.C. TO PROVIDE 1" CONDUIT (RIGID) THRU - ROOF FOR SATELLITE SYSTEM. PENETRATION SHALL BE SEALED WATER TIGHT. COORDINATE WITH SATELLITE INSTALLER. DBR 37 TELCOM PLAN E4.0 COMMUNICATIONS LEGEND D COMMUNICATIONS NOTES D SECURITY SYSTEM NOTES C KEY NOTES B PLOT DATE: *CONTRACTOR SHALL VERIFY ALL EQUIPMENT LOADS, VOLTAGE, AMPS, DISCONNECT, AND/OR PLUG REQUIREMENTS WITH OWNERS EQUIPMENT BEFORE START OF WORK. N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 KITCHEN EQUIPMENT PANEL A GENERAL NOTE: *CONTRACTOR SHALL VERIFY ALL EQUIPMENT LOADS, VOLTAGE, AMPS, DISCONNECT, AND/OR PLUG REQUIREMENTS WITH OWNERS EQUIPMENT BEFORE START OF WORK. LIGHTING CIRCUITS INSIDE THE BUILDING SHALL BE WIRED THRU LIGHTING CONTACTORS. REFER TO DETAILS ON SHEET E6.0. PANELBOARD NOTES: 1 PROVIDE LOCK-ON BREAKER. 2 CIRCUITS TO BE WIRED THRU EXTERIOR LIGHTING CONTROL RELAY. SEE DETAIL 8/E6.0. 3 CIRCUITS TO BE WIRED THRU THE LIGHTING CONTROL RELAY-FRONT. SEE DETAIL 18/E6.0. 4 CIRCUITS TO BE WIRED THRU THE LIGHTING CONTROL RELAY-REAR. SEE DETAIL 14/E6.0. 5 6 LOAD KEY LEGEND LOAD DESCRIPTION CIRCUIT BREAKER INDICATED SHALL BE A SHUNT TRIP CIRCUIT BREAKER CONTROLLED BY HOOD'S FIRE EXTINGUISHER SYSTEM. WESTERN REGION PANELS WILL HAVE A STANDARD 42KAIC RATING. WHEN GE PANELS ARE USED IN THE WESTERN REGION PANELS WILL HAVE A 65 KAIC RATING. EASTERN REGION PANELS WILL HAVE A 22KAIC RATING. APPLICABLE FACTOR L LIGHTING 125% K KITCHEN EQUIPMENT 65% H HVAC 100% M MISC. EQUIPMENT 100% LOAD SUMMARY & LEGEND CONDUCTORS DESIG. SETS NO. SIZE GROUND ISOLATED CONDUIT SIZE GROUND SIZE PER SET SIZE PER SET 1 1 4 #500 KCM 16 #3 #6 3-1/2" 2 1 4 #3/0 #6 #6 2" C E.C. SHALL COORDINATE WITH POWER COMPANY TO REMOVE EXISTING 120/208V 200A METER. E.C. SHALL REMOVE EXISTING 200A DISC. ALONG WITH ASSOCIATED FEEDER & CONDUIT BACK TO TENANT SPACE. E.C. SHALL REMOVE EXISTING PANEL (S) AND REPLACE WITH NEW PANELS. KITCHEN EQUIPMENT PANEL NOTES: 1. PROVIDE OTHER GROUND CONNECTIONS AS SPECIFIED IN N.E.C. ARTICLE 250-50. (1999) 2. LIGHTING CONTROL PANEL SHALL BE RECESSED DIRECTLY BELOW ELECTRICAL PANEL "B". 3. COORDINATE W/ POWER CO., PROVIDE C.T. CABINET IF REQUIRED . 4. PROVIDE NEW SERVICE GROUNDS IF NO EXISTING SERVICE GROUND. VERIFY IN FIELD. B CONTRACT DATE: 09.21.15 BUILDING TYPE: DBR 37 PLAN VERSION: 009.00.00 SITE NUMBER: 311465 / 434385 STORE NUMBER: 2015388.14 PIZZA HUT NEW UTILITY CO. METERING SEE NOTE #3 BELOW 123 Minden Shopping Dr. Minden, LA 71055 EXISTING WIREWAY A EXISTING 1200A., 120/208V., 3PH., 4 WIRE, SERVICE DISCONNECT SWITCH NEW 400A., 120/208V., 3PH., 4 WIRE, FUSED, DISCONNECT SWITCH, SERVICE ENTRANCE RATED, NEMA 3R EXISTING 1200A., FEEDERS FROM UTILITY TRANSFORMER 1-#1/0 - 1" CONDUIT TO WATER SERVICE WHERE SERVICE ENTERS BUILDING. (NOTE 2) EXISTING TENANT'S METERS AND DISCONNECTS (TYPICAL) B DBR 37 LTG CNTL RELAY (NOTE 2) PANEL SCHEDULE & RISER DIAGRAM EXISTING SERVICE GROUND, SEE NOTE 4. 1-#1/0 -3 4" CONDUIT TO 3 4" DIAMETER X 10'-0" LONG COPPERCLAD GROUND ROD W/ 'CADWELD' CONNECTION. (NOTE 2) E5.0 SINGLE LINE DIAGRAM D PLOT DATE: RTU TERMINAL STRIP (RTRM) SEQUENCE OF OPERATION: AFTER COMPLETION AND TESTING OF THE INTERLOCK SYSTEM SHOWN BELOW, BUT BEFORE PUTTING IT INTO OPERATION, PROGRAM THERMOSTATS FOR RTU1 AND RRU2 TO INITIATE "OCCUPIED" TEMPERATURE SETTINGS AT TIME OF ARRIVAL OF FIRST EMPLOYEE OR MANAGER. (APPROXIMATELY 8:00 A.M.) THIS INTERLOCK SYSTEM IS INTENDED TO: 1. MAKE AVAILABLE A FULL VOLUME OF OUTSIDE AIR TO THE BUILDING WHEN ALL EXHAUST FANS ARE ACTIVATED BY THE "OCCUPIED" RELAY JUMPER SMOKE DETECTORS LOCATED IN SUPPLY AIR DUCTS. INCLUDE IN RETURN DUCTS ONLY WHERE REQUIRED BY LOCAL CODE. WIRE TO SHUTDOWN AC UNITS UPON DETECTION OF SMOKE. N O I T C Y U L R N T O S S N E O S C O D P R R A U N P I U D I O B H C OR F 2. STOP THE FLOW OF OUTSIDE AIR FROM THE RTUs BY DE-ENERGIZING UNITS WHEN ANY HOOD FIRE SUPPRESSION SYSTEM IS ACTIVATED. CONTACT LC-7 SHALL ENABLE THE EXHAUST FAN CONTROL RELAY "R3" TO SENSE THE "OCCUPIED" (OR "UNOCCUPIED" CONDITION. (REFER TO DET. 2, SHT E6_0 FOR SEQUENCE OF OPER.) NOTES: 1. REFER TO THE ELECTRICAL ROOF PLAN, E2.0 FOR UNIT LOCATIONS 2. REFER TO THE MECHANICAL SCHEDULES ON SHEET M1 FOR ELECTRICAL REQUIREMENTS SEQUENCE OF OPERATION: CONTACT LC-8 SHALL ENABLE THE LIGHTING CONTROL RELAY-EXT TO BEGIN THE "OCCUPIED" SEQUENCES PROGRAMMED INTO IT (REFER TO DET 8, SHT E6_0). OCCUPIED: UNOCCUPIED: KITCHEN EXHAUST FANS SHALL CEASE OPERATE OPERATION WHEN RELAY "R3" IS DE-ENERGIZED CORRESPONDING TO TURNING OFF THE LIGHT SWITCH IN THE KITCHEN. SPACE THERMOSTATS SHALL CYCLE ROOFTOPS' FANS AND HEATING OR COOLING TO MAINTAIN "UNOCCUPIED" SPACE TEMPERATURES. A-15 B-20 B-22 UNDER SLAB CONDUIT N.T.S. 17 "LC" C LC- 1 2 3 4 5 6 7 EQUIPMENT CONTROL 8 R4 120V PANEL "A" CKT. 14 CIRCUIT BREAKER B-42 B-41 B-33 B-29 B-27 FROM ELECTRICAL PANELS C R4- 1 (SEE 16/E6.0) RECESSED DOWNLIGHTS TELEVISIONS 6 7 8 FREEZER/COOLER LIGHTS DINING PEND/DOWN LTS 5 SPARE 4 SPARE 3 SPARE 2 TELEVISIONS FC- 1 DINING TRACK LTS C WOMEN RESTROOM MEN RESTROOM KITCHEN LIGHTS "FC" HOOD EXHAUST FAN CONTROL C N.T.S. 18 SPST SWITCH #2. SEE E4.0 FOR LOC'N. KEYNOTE TO TO RTU-1 RTU-2 SPARE SPARE T-STAT T-STAT ELECTRICALLY HELD, 4-POLE 120 VOLT AC 20 AMP CONTINUOUS DUTY LIGHTING CONTACTOR. SPARE SHUNT-TRIP ELECTRICALLY HELD, 120 VOLT AC 20 AMP CONTINUOUS DUTY LIGHTING CONTACTOR. 7 FRYER HOOD LIGHTS 8 SPARE SPARE BC- 4 3 2 REFER TO NOTES ABOVE N.T.S. 1 NEUT C NEUT (A-15) 14 HOOD SHUT-DOWN DETAIL SEQUENCE OF OPERATIONS: * SET TIME CLOCK FOR THE HOURS THE STORE WILL BE OCCUPIED- COORDINATE WITH OWNER'S REPRESENTATIVE. * ADJUST PHOTOCELL TO ACTIVATE WHEN AMBIENT LIGHT APPROXIMATES DUSK COORDINATE WITH OWNER'S REPRESENTATIVE * SET BOTH SWITCHES TO THE "AUTOMATIC" POSTITION. SIGNS AND LIGHTS WILL NOW BE ENERGIZED WHEN THE TIME CLOCK INDICATES THE STORE IS OCCUPIED AND THE PHOTOCELL INDICATES LOW LIGHT LEVELS. * WHEN THE STORE CLOSES BUT IS STILL OCCUPIED, THE SIGNS/ BUILDING LIGHTS SWITCH SHOULD BE TURNED TO "OFF" TO EXTINGUISH THESE LIGHTS. * WHEN THE CREW LEAVES THE TIMECLOCK WILL TURN OFF ALL EXTERIOR LIGHTS - THE 30 MINUTE DELAY TIMER IS USED TO PROVIDE POWER TO THE SITE LIGHTS FOR ENOUGH TIME TO ALLOW THE CREW TO LEAVE SAFELY. OVEN HOOD HEAT SENSOR N.T.S. 2 PHOTOCELL TORK #2101, MOUNT FACING NORTH. CALIBRATE TO OPERATE WHEN AMBIENT LIGHT APPROXIMATES DUSK. COORDINATE WITH OWNER'S REPRESENTATIVE ON CIRCUIT A-14 N L TIMECLOCK TORK #1101 MOUNT ON WALL ABOVE ENCLOSURE A 120V COIL O * SEE LIGHTING PLANS FOR CIRCUIT NUMBERS. CONTRACT DATE: H C 20A HAND-OFFAUTOMATIC (HOA) SWITCH. MOUNT IN ENCLOSURE PILOT-LIGHT SWTICH MOUNTED ON HOOD FACE FOR FRYER HOOD FAN SHUT-DOWN. 0 SIGN/ BLDG. LTS. E-MAX THERMOSTAT T NOT USED 120V COIL O B-19 H NEUT (B-19) 3 EQUIPMENT SHUT-DOWN DETAIL N.T.S. 16 THERMOSTAT (TRANE) 30 MINUTE TWIST TIMER FOR PARKING LOT LIGHT DELAY MOUNT IN ENCLOSURE COOL OFF HEAT HEAT 1 W1 G RC 311465 / 434385 2015388.14 PIZZA HUT FAN ON COOL AUTO OFF W1 W2 G DBR 37 HEAT NORMALLY OPEN ELECTRICALLY HELD RELAY WITH 120V COIL AND 30 AMP CONT. DUTY CONTACTS FOR SITE LIGHTS MOUNT IN ENCLOSURE N.T.S. 009.00.00 ROOF TOP UNIT (TERMINAL BOARD 3J7 CTI) HEAT 2 W2 20A HAND-OFFAUTOMATIC (HOA) SWITCH. MOUNT IN ENCLOSURE EXTERIOR LIGHTING CONTROL SCHEMATIC PLAN VERSION: 123 Minden Shopping Dr. Minden, LA 71055 COOL OFF Y1 ELECTRICAL DETAILS Y1 COOL 1 HEAT Y2 COOL 2 COMMON Y2 COMMON E6.0 YER055 SITE LTS. N.T.S. 2-10 TON PRECEDENT UNIT RH OVEN HOOD EXHAUST FAN WING HOOD EXHAUST FAN THERMOSTAT CONTACT PIZZA HOOD LIGHTS 30 DBR 37 STORE NUMBER: NORMALLY OPEN ELECTRICALLY HELD RELAY WITH 120V COIL AND 30 AMP CONT. DUTY CONTACTS FOR BUILDING LIGHTS AND SIGNAGE MOUNT IN ENCLOSURE 09.21.15 BUILDING TYPE: SITE NUMBER: C A NEUT AUX PIZZA HOOD LIGHTS C FAN CONTROL RELAY OVEN HOOD EXHAUST FAN S FAN MOTOR STARTER SEE PLANS FOR CIRCUIT NUMBER IN PANEL "B" O.L. C 10 SHUNT-TRIP SPST SWITCH IN KITCHEN 4 LIGHTING & CONTROL RELAY - REAR FRYER EXHAUST FAN FAN MOTOR STARTER SEE PLANS FOR CIRCUIT NUMBER IN PANEL "B" LOW VOLTAGE TERMINAL BOARD (LTB) O.L. "LC" RTU BLOWER CONTROL RELAY 20A,1P, 120V NON FUSED, NEMA 3R DISCONNECT SWITCH ON ROOF (TYP) FRYER HOOD (SEE 2/E6.0) R3- 1 20A, 1P, 120V NON FUSED, NEMA 3R DISCONNECT SWITCH ON ROOF HARDWARE SPECIFICATIONS: HOFFMAN A-HE SERIES WITH HINGED COVER AND CYLINDER KEY LOCK SET. RELAYS: SQUARE-D CLASS 8501, RS43, V20 WITH SOCKET BASE. R3 "BC" LIGHTING CONTROL RELAY - FRONT EMERGENCY OPERATION: UPON ACTIVATION OF ANY HOOD FIRE SUPPRESSION RELAY, A RELAY IN THAT FIRE SUPPRESSION SYSTEM SHALL CAUSE THE SHUNT TRIP CONTROLLED DEVICES TO OPERATE, THUS REMOVING POWER FROM ALL OTHER DEVICES CONNECTED TO THAT PANEL. EXHAUST FANS SHALL NOT BE AFFECTED BY THIS ACTION AND SHALL CONTINUE TO BE CONTROLLED BY THE "OCCUPIED" OR "NON-OCCUPIED" CONDITIONS LISTED ABOVE. 5 M EF-3 120V PANEL "A" CKT. 14 ALARM CONTACTS SPACE THERMOSTATS SHALL CYCLE ROOF TOP UNITS TO MAINTAIN "OCCUPIED" SPACE TEMPERATURES. BLOWER MOTORS SHALL OPERATE AS NOTED IN DETAIL 14, SHT E6_0. CIRCUIT BREAKERS (TYP) 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 REMOVE JUMPER 2-10 TON PRECEDENT UNIT SMOKE DETECTOR ACTIVATION OF RELAY "BC" (BLOWER CONTROL) SHALL CAUSE THE THERMOSTATS ON ALL ROOF TOP UNITS TO START THE BLOWERS ON RTU-1 AND RTU-2. EACH RTU BLOWER MOTOR SHALL RUN CONTINUOUSLY UNTIL EITHER BC-1 IS DEACTIVATED BY TURNING OFF THE KITCHEN LIGHTS OR WHEN A SMOKE DETECTOR ON AN INDIVIDUAL SHALL SHUT THAT UNIT DOWN INDIVIDUALLY AS REQUIRED BY NFPA. REFER TO PANEL BOARD SCHEDULES 24 VAC 8 THERMOSTAT DETAIL N.T.S. 4 PLOT DATE:
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement