user manual
EN
USER'S MANUAL
NEW MULTI SYSTEM
MS-E14AIN, MS-E18AIN,
MS-E21AIN, MS-E24AIN, MS-E28AIN
“Originalinstructions”
In line with the company’s policy of continual product improvement, the aesthetic and dimensional
characteristics, technical data and accessories of this appliance may be changed without notice.
GENERAL INFORMATION
INSTALLER
GENERAL
INFORMATION
CONTENTS
Conformity And Range
1
Warning
2
The Instructions Before Use
5
Name of Parts
6
Technical Data
8
Outdoor Unit Working Temperature Range
8
Electrical Connections
9
Installing The Outdoor Unit
13
Bleeding
13
Maintenance
14
Installation Dimension Diagram
14
Check After Installation
15
The products in this manual may be different lwith the rea one, according to different models,
some models have displayer and some models without displayer, the position and shape of
the displayer please refer to the real one.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
Children should be supervised to ensure that they do not play with the appliance.
This marking indicates that this product should not be disposed with other
household wastes throughout the EU. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, recycle
it responsibly to promote the sustainable reuse of material resources. To
return your used device, please use the return and collection systems or
contact the retailer where the product was purchased. They can take this
product for environmental safe recycling.
GENERAL INFORMATION
CONFORMITY AND RANGE
Please read this owner's manual carefully before operating the unit and keep it carefully for consultation.
Only use the air conditioner as instructed in this booklet. These instructions are not intended to
cover every possible condition and situation. As with any electrical household appliance, common sense
and caution are therefore always recommended for installation, operation and maintenance.
1
GENERAL INFORMATION
Warning
Operation and Maintenance
This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory ormental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without
supervision.
Do not connect air conditioner to multi-purpose socket. Otherwise, it may
cause fire hazard.
Do disconnect power supply when cleaning air conditioner. Otherwise, it
may cause electric shock.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
Do not wash the air conditioner with water to avoid electric shock.
Donot spray wateronindoorunit. It may cause electric shock ormalfunction.
After removing the filter, do not touch fins to avoid injury.
Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard.
Maintenance must be performed by qualified professionals. Otherwise, it may
cause personal injury or damage.
Do not repair air conditioner by yourself. It may cause electric shock or damage.
Please contact dealer when you need to repair air conditioner.
Do not extend fingers or objects into air inlet or air outlet. It may cause personal
injury or damage.
Do not block air outlet or air inlet. It may cause malfunction.
Do not spill water on the remote controller, otherwise the remote controller ma
be broken.
When below phenomenon occurs, please turn off air conditioner and disconnect
power immediately,and then contact the dealer or qualified professionals for
service.
Power cord is overheating or damaged.
There’s abnormal sound during operation.
Circuit break trips off frequently.
Air conditioner gives off burning smell.
Indoor unit is leaking.
2
GENERAL INFORMATION
Warning
If the air conditioner operates under abnormal conditions, it may cause
malfunction,electric shock or fire hazard.
When turning on or turning off the unit by emergency operation switch, please
press this switch with an insulating object other than metal.
Do not step on top panel of outdoor unit, or put heavy objects. It may cause
damage or personal injury.
Attachment
Installation must be performed by qualified professionals. Otherwise, it may
cause personal injury or damage.
Must follow the electric safety regulations when installing the unit.
According to the local safety regulations, use qualified power supply circuit
and circuit break.
Do install the circuit break. If not, it may cause malfunction.
An all-pole disconnection switch having a contact separation of at least 3mm in
all poles should be connected in fixed wiring.
Including an circuit break with suitable capacity, please note the following table.
Air switch should be included magnet buckle and heating buckle function, it can
protect the circuit-short and overload.
Air Conditioner should be properly grounded. Incorrect grounding may cause
electric shock.
Don't use unqualified power cord.
Make sure the power supply matches with the requirement of air conditioner.
Unstable power supply or incorrect wiring or malfunction. Please install proper
power supply cables before using the air conditioner.
Properly connect the live wire, neutral wire and grounding wire of power socket.
Be sure to cut off the power supply before proceeding any work related to
electricity and safety.
Do not put through the power before finishing installation.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
The temperature of refrigerant circuit will be high, please keep the
interconnection cable away from the copper tube.
The appliance shall be installed in accordance with national wiring regulations.
Installation must be performed in accordance with the requirement of NEC and
CEC by authorized personnel only.
3
GENERAL INFORMATION
Warning
The air conditioner is the first class electric appliance. It must be properly
grounding with specialized grounding device by a professional. Please make
sure it is always grounded effectively, otherwise it may cause electric shock.
The yellow-green wire in air conditioner is grounding wire, which can't be used
for other purposes.
The grounding resistance should comply with national electric safety regulations.
The appliance must be positioned so that the plug is accessible.
All wires of indoor unit and outdoor unit should be connected by a professional.
If the length of power connection wire is insufficient,please contact the
supplier for a new one. Avoid extending the wire by yourself.
For the air conditioner with plug,the plug should be reachable after finishing
installation.
For the air conditioner without plug, an circuit break must be installed in the line.
If you need to relocate the air conditioner to another place, only the qualified
person can perform the work. Otherwise, it may cause personal injury or damage.
Select a location which is out of reach for children and far away from animals or
plants.If it is unavoidable, please add the fence for safety purpose.
The indoor unit should be installed close to the wall.
4
THE INSTRUCTIONS BEFORE USE
GENERAL INFORMATION
WARNING
ƾ When having a burning smell or ƾ The power supply must adopt the
smoke,please turn off the power
supply and contact with the service center.
special circuit that with air switch
protection and assure it has enough capacity.The unit will be turned
on or off according to your requirement automatically,please do not
turn on or turn off the unit frequently,otherwise disadvantage effect
may be caused to the unit.
ƾ Never cut off or damage power
cables and control wires. If the
power cable and signal control
wire were damaged, change
them by professional.
If the abnormity still exists,the unit
may be damaged,and may cause
electric shock or fire.
ƾ Power must adopts the special
ƾ Disconnect the power supply if
ƾ Never damage the electric wire
Otherwise, it can cause electric
shock or fire.
Otherwise,the accumulated dusts
may cause overheating or fire.
Otherwise,it will cause overheating
or fire.
ƾ When cleaning,it is necessary
ƾ Rated voltage of this air conditi-
ƾ Don't attempt to repair the air
circuit to prevent fire.
to stop driving and turn off the
power supply.
Cut off power supply
long putting the air conditioner
out of use.
oner 220-240V, 50Hz, The compressor will vibrate sharply if the
voltage is too low, resappointed.
amage to refrigerating system.
Electrical component are easy to
damage if the voltage is too high.
conditioner by yourself.
The wrong repair will lead to an
electric shock or fire,so you should
contact the service center to repair.
Otherwise,it may cause electric
shock or damage.
ƾ Please note whether the insta-
ƾ Don't step on the top of the
If it is damaged, it may lead to the
fall of the unit and cause the injury.
As falling off the outdoor unit can be
dangerous.
lled stand is firm enough or not.
or use the electric wire which is
not appointed.
outdoor unit or place something
on it.
5
ƾ Earthing: The unit must be reli-
ably earthed.The earthing cable
shall be connected to the special earthing device in the construction.
NAME OF PARTS
GENERAL INFORMATION
MS-E18AIN, MS-E21AIN
Warning
Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric
shock might happen.
Wetting of air conditioner may cause the risk of electric shock. Make sure not to wash
your air conditioner in any case.
Volatile liquids such as thinner or gasoline will cause damage to the appearance of air
conditioner. (Only use soft dry cloth moist cloth clean the air conditioner cabinet).
This product must not be disposed together with the domestic waste.
This product has to be disposed at an authorized place for recycling of electrical and
electronic appliances.
The temperature of refrigerant circuit will be high,please keep the interconnection cable
away from the copper tube.
1
OUTDOOR UNIT
No.
Description
1
Air outlet grille
2
Valve
Note: The above figures are only intended to a simple
diagram of the appliance and may not correspond to the
appearance of the units that have been purchased.
2
MS-E24AIN, MS-E28AIN
Warning
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly
qualified person in order to avoid a hazard.
Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric shock might happen.
Wetting of air conditioner may cause the risk of electric shock. Make sure not to wash your air conditioner in
any case.
Volatile liquids such as thinner or gasoline will cause damage to the appearance of air conditioner. (Only use
soft dry cloth moist cloth clean the air conditioner cabinet).
Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special
treatment is necessary.
The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper
tube.
OUTDOOR UNIT
No.
1
Description
1
Air outlet grille
2
Valve
Note: The above figures are only intended to be a simple
diagram of the appliance and may not correspond to
the appearance of the units that have been purchased.
2
6
NAME OF PARTS
GENERAL INFORMATION
MS-E14AIN
Warning
Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric
shock might happen.
Wetting of air conditioner may cause the risk of electric shock. Make sure not to wash
your air conditioner in any case.
Volatile liquids such as thinner or gasoline will cause damage to the appearance of air
conditioner. (Only use soft dry cloth moist cloth clean the air conditioner cabinet).
This product must not be disposed together with the domestic waste.
This product has to be disposed at an authorized place for recycling of electrical and
electronic appliances.
The temperature of refrigerant circuit will be high,please keep the interconnection cable
away from the copper tube.
1
OUTDOOR UNIT
No.
Description
1
Air outlet grille
2
Valve
Note: The above figures are only intended to a simple
diagram of the appliance and may not correspond to the
appearance of the units that have been purchased.
7
2
TECHNICAL DATA
GENERAL INFORMATION
MODE
Electrical data
Electricity supply
Fuse or air switch
Minimum power cord section
MS-E21AIN
MS-E18AIN
MS-E14AIN
220-240V~,50Hz
16
2.5
220-240V~,50Hz
16
2.5
25
2.5
mm 2
Size and clearance
L
P
H
L
899
890
mm
P
378
362
mm
H
596
700
mm
TECHNICAL DATA
GENERAL INFORMATION
MODE
Electrical data
Electricity supply
Fuse or air switch
Minimum power cord section
MS-E24AIN, MS-E28AIN
220-240V~,50Hz
25
2.5
mm 2
L
920
mm
P
380
mm
H
790
mm
Size and clearance
L
P
H
OUTDOOR UNIT WORKING TEMPERATURE RANGE
Maximum cooling
Maximum heating
GENERAL INFORMATION
Outdoor side DB/WB(ć )
43/26
24/18
Indoor side DB/WB(ć )
32/23
27/-
ƔThe operating temperature range (outdoor temperature) for cooling only unit is
-15ć ~43ć ; for heat pump unit is -15ć ~ 24ć .
Model
Max. connection pipe length
Max. connection pipe length (One indoor unit)
Outdoor unit is installed under the lower
side of indoor unit
Max. installation altitude
Outdoor unit is installed on the upper
side of indoor unit
Max. connection pipe length (Under the condition of no need to
charge the refrigerant, liquid pipe total length)
Refrigerant charge volume
m
m
MS-E14AIN
20
10
MS-E18AIN
20
10
MS-E21AIN
60
20
MS-E24AIN
60
20
MS-E28AIN
70
20
m
5
5
10
10
10
m
5
5
10
10
10
m
10
10
30
30
40
20
g/m
8
ELECTRICAL CONNECTIONS
INSTALLER
MS -E 18AIN, MS -E 21AIN, MS -E 24AIN
1. Remove the handle at the right side plate of the outdoor MS-E18AIN
unit (one screw).
2. Remove the cable clamp, connect the power connection
cable with the terminal at the row of connection and fix
the connection. The fitting line distributing must be
consistent with the indoor unit. terminal of line bank.
Wiring should meet that of indoor unit.
3. Fix power connection wire by wire clamp.
4. Ensure wire has been fixed well.
5. Install the handle.
Including an air switch with suitable capacity,
please note the following table. Air switch
L
should be included magnet buckle and heating
buckle function, it can protect the circuit-short
and overload. (Caution: please do not use the
fuse only for protect the circuit)
Handle
To unit A
Power cord
Air-conditioner
Air switch capacity
MS-E18AIN
10A
MS-E21AIN
25A
MS-E24AIN
25A
L
Note: the above figures are only intended to be a simple
diagram of the appliance and may not correspond to the
appearance of the units that have been purchased.
MS-E21AIN
Handle
To unit C
To unit B
L
Power cord
connecting
cable
connecting
cable
connecting
cable
To the power supply
An all-pole disconnection switch having a contact
separation of at least 3mm in all pole should be
connected in fixed wiring.
Wrong wire connection may cause malfunction of
some electric components.After fixing cable, ensure
that leads between connection to fixed point have
some space.
The connection pipes and the connectiong wirings
of the unit A and unit B must be corresponding to
each other respective.
The appliance shall be installed in accordance with
national wiring regulations.
To unit A
connecting
cable
To unit B
connecting
cable
To the power supply
C
L
N
L
C
9
N
L
ELECTRICAL CONNECTIONS
INSTALLER
MS-E24AIN
An all-pole disconnection switch having a contact
separation of at least 3mm in all pole should be
connected in fixed wiring.
1. Remove the handle at the right side plate of the
outdoor unit (one screw).
3. Fix power connection wire by wire clamp.
2. Remove the cable clamp, connect the power
connection cable with the terminal at the row of
connection and fix the connection. The fitting line
distributing must be consistent with the indoor
unit. terminal of line bank. Wiring should meet
that of indoor unit.
Wrong wire connection may cause malfunction of
some electric components.After fixing cable, ensure
that leads between connection to fixed point have
some space.
The connection pipes and the connectiong wirings
of the unit A ,unit B and unit C must be corresponding to each other respective.
4. Ensure wire has been fixed well.
5. Install the handle.
Including an air switch with suitable capacity,
please note the following table. Air switch
should be included magnet buckle and heating
buckle function, it can protect the circuit-short
and overload. (Caution: please do not use the
fuse only for protect the circuit)
Air-conditioner
Air switch capacity
MS-E24AIN
25A
The appliance shall be installed in accordance with
national wiring regulations.
Note: The above figures are only intended to be a simple
diagram of the appliance and may not correspond to the
appearance of the units that have been purchased.
Handle
To unit A
To unit B
To unit C
L
Power cord
connecting
cable
connecting
cable
connecting
cable
To the power supply
Outdoor unit
L
Indoor unit
10
ELECTRICAL CONNECTIONS
INSTALLER
MS-E28AIN
1. Remove the handle at the right side plate of the
outdoor unit (one screw).
An all-pole disconnection switch having a contact
separation of at least 3mm in all pole should be
connected in fixed wiring.
3. Fix power connection wire by wire clamp.
2. Remove the cable clamp, connect the power
connection cable with the terminal at the row of
connection and fix the connection. The fitting line
distributing must be consistent with the indoor
unit. terminal of line bank. Wiring should meet
that of indoor unit.
Wrong wire connection may cause malfunction of
some electric components.After fixing cable, ensure
that leads between connection to fixed point have
some space.
The connection pipes and the connectiong wirings
ofthe unit A, unit B, unit C and unit D must be
corresponding to each other respective.
4. Ensure wire has been fixed well.
5. Install the handle.
Including an air switch with suitable capacity,
please note the following table. Air switch
should be included magnet buckle and heating
buckle function, it can protect the circuit-short
and overload. (Caution: please do not use the
fuse only for protect the circuit)
Air-conditioner
Air switch capacity
MS-E28AIN
25A
The appliance shall be installed in accordance with
national wiring regulations.
Note: The above figures are only intended to be a simple
diagram of the appliance and may not correspond to the
appearance of the units that have been purchased.
Handle
To unit A
To unit B
To unit C
To unit D
L
Power cord
connecting
cable
connecting
cable
connecting
cable
connecting
cable
To the power supply
Outdoor unit
L
Indoor unit
11
ELECTRICAL CONNECTIONS
INSTALLER
MS-E14AIN
1. Remove the handle at the right side plate of the
outdoor unit (one screw).
An all-pole disconnection switch having a contact
separation of at least 3mm in all pole should be
connected in fixed wiring.
3. Fix power connection wire by wire clamp.
2. Remove the cable clamp, connect the power
connection cable with the terminal at the row of
connection and fix the connection. The fitting line
distributing must be consistent with the indoor
unit. terminal of line bank. Wiring should meet
that of indoor unit.
Wrong wire connection may cause malfunction of
some electric components.After fixing cable, ensure
that leads between connection to fixed point have
some space.
The connection pipes and the connectiong wirings
ofthe unit A, unit B, unit C and unit D must be
corresponding to each other respective.
4. Ensure wire has been fixed well.
5. Install the handle.
Including an air switch with suitable capacity,
please note the following table. Air switch
should be included magnet buckle and heating
buckle function, it can protect the circuit-short
and overload. (Caution: please do not use the
fuse only for protect the circuit)
Air-conditioner
Air switch capacity
MS-E14AIN
10A
The appliance shall be installed in accordance with
national wiring regulations.
Note: The above figures are only intended to be a simple
diagram of the appliance and may not correspond to the
appearance of the units that have been purchased.
Handle
Front
side plate
To the power supply
To unit A
To unit B
L
L
N
L
Power cord
connecting
cable
connecting
cable
USER
HANDLING
Handling must be done by suitably equipped qualified
technical personnel using equipment that is for suitable
the weight of the appliance.
After having removed the packaging, check that the
contents are intact and complete.
The outdoor unit must always be kept upright.
12
INSTALLING THE OUTDOOR UNIT
INSTALLER
Location
Use bolts to secure the unit to a flat, solid floor.
When mounting the unit on a wall or the roof, make
sure the support is firmly secured so that it cannot
move in the event of intense vibrations or a strong
wind.
Do not install the outdoor unit in pits or air vents
Ɣ
Installing the pipes
Use suitable connecting pipes and equipment for
the refrigerant R410A.
Install the drain fitting and the drain hose
(for model with heat pump only)
Condensation is produced and flows from the outdoor unit when the appliance is operating in the
heating mode. In order not to disturb neighbours
and to respect the environment,install a drain fitting
and a drain hose to channel the condensate water.
Install the drain fitting and rubber washer on the
outdoor unit chassis and connect a drain hose to it
as shown in the figure.
Models(m)
14Kx2 18Kx2 21Kx3 24Kx3 28Kx4
20
20
60
60
70
Max. connection pipe length
Max. connection pipe length
20
10
10
20
20
(Simple one indoor unit)
The sum of the capacity codes of the indoor units should be
among 50%-150% of that of the outdoor unit.
The refrigerant pipes must not exceed the maximum
heights 5m(14K&18K)or 10m(21K&24K&28K).
Wrap all the refrigerant pipes and joints.
Tighten the connections using two wrenches working in opposite directions.
Caution: Installation Must be Performed in Accordance
with the NEC/CEC by Authorized Personnel Only.
BLEEDING
INSTALLER
Humid air left inside the refrigerant circuit can cause compressor malfunction. After having connected the indoor
and outdoor units, bleed the air and humidity from the
refrigerant circuit using a vacuum pump.
(1) Unscrew and remove the caps from the 2-way and 3way valves.
(2) Unscrew and remove the cap from the service valve.
(3) Connect the vacuum pump hose to the service valve.
(4) Operate the vacuum pump for 10-15 minutes until an
absolute vacuum of 10 mm Hg has been reached.
(5) With the vacuum pump still in operation, close the
low-pressure knob on the vacuum pump coupling.
Stop the vacuum pump.
(6) Open the 2-way valve by 1/4 turn and then close it
after 10 seconds. Check all the joints for leaks using
liquid soap or an electronic leak device.
(7) Turn the body of the 2-way and 3-way valves. Disconnect the vacuum pump hose.
(8) Replace and tighten all the caps on the valves.
Diameter (mm)
Twisting moment (N.m)
ĭ
15-20
ĭ
35-40
ĭ
60-65
ĭ
45-50
ĭ
70-75
Vacuum pump
Vacuum pump
Vacuum pump
(8) Secure
INDOOR
UNIT
Refrigerant fluid direction of fiow
18K unit need to be installed the indoor unit
2-way valve
3-way valve
(6) Open by 1/4 turn
18K MODE:
(7)Turn to open fully
Service
inlet
(2)Turn
(8) Secure
conversion joint
13
(7)Turn to open fully
Valve cap
(2)Turn
(2)Turn
Valve cap
(8) Secure
Connect to the
indoor unit
MAINTENANCE
INSTALLER
Use suitable instruments for the refrigerant R410A.
ƽ Do not use any other refrigerant than R410A.
Do not use mineral oils to clean the unit.
INSTALLATION DIMENSION DIAGRAM
INSTALLER
The installation must be done by trained and qualified service personnel with reliability according to this
manual.
Contact service center before installation to avoid the malfunction due to unprofessional installation.
When picking up and moving the units, you must be guidedby trained and qualified person.
Ensure that the recommende dspace is left around the appliance.
MS-E18AIN
MS-E21AIN
MS-E24AIN
MS-E28AIN
50cm or more
Space to the cover
30cm or above
(Air inlet side)
30cm or above
Space to the cover
200cm or above
(Air outlet side)
50cm or more
Space to the cover
30cm or above
(Air inlet side)
30cm or above
Space to the cover
200cm or above
(Air outlet side)
50cm or above
Space to the wall
50cm or
above
S p a c e to
th e w a ll
MS-E14AIN
50cm or more
Space to the cover
30cm or above
(Air inlet side)
30cm or above
Space to the cover
200cm or above
(Air outlet side)
50cm or above
Space to the wall
14
CHEC
AFTER INSTALLATION
INSTALLER
Check Items
Problems Owing to Improper Installation
Is the installation reliable?
The unit may drop, vibrate or make noises
Has the gas leakage been checked?
May cause unsatisfactory cooling (heating)
effect
Is the thermal insulation of the unit
sufficient?
May cause condensation and water dropping
Is the drainage smooth?
May cause condensation and water dropping
Does the power supply voltage accord
with the rated voltage specified on the
nameplate?
The unit may bread down or the components
may be burned out
Are the lines and pipelines correctly
installed?
The unit may bread down or the components
may be burned out
Has the unit been safely grounded?
Risk of electrical leakage
Are the models of lines in conformity
with requirements?
The unit may bread down or the components
may be burned out
Are there any obstacles near the air
inlet and outlet of the indoor and outdoor units?
The unit may bread down or the components
may be burned out
Have the length of refrigerating pipe
and refrigerant charge amount been
recorded?
It is not easy to decide the charge amount
of refrigerant.
15
NOTE CONCERNING PROTECTION OF ENVIRONMENT
This product must not be disposed of via normal household waste after its
service life, but must be taken to a collection station for the recycling of
electrical and electronic devices. The symbol on the product, the
operating instructions or the packaging indicate such disposal procedures.
The materials are recyclable in accordance with their respective symbols. By means
of re-use, material recycling or any other form of recycling old appliances you are
making an important contribution to the protection of our environment. Please ask
your local council where your nearest disposal station is located.
INFORMATION CONCERNING USED REFRIGERANT
MEDIUM
This unit is containing fluorinated gases included in the Kyoto protocol. The
maintanance and the liquidation must be carried out by qualified personel.
Type of refrigerant: R410A
The composition of the cooling medium R410A: (50% HFC-32, 50% HFC-125)
The quantity of the refrigerant: please see the unit label.
The value GWP: 2088
GWP = Global Warming Potential
In case of quality problem or other please contact your local supplier or authorized
service center.
Emergency number: 112
PRODUCER
Producer: SINCLAIR CORPORATION Ltd., 1-4 Argyll St., London W1F 7LD, UK,
www.sinclair-eu.com
This product was manufactured in China (Made in China).
REPRESENTATIVE, TECHNICAL SUPPORT
NEPA spol. s r.o.
Purkyňova 45
612 00 Brno
Czech Republic
Tel.: +420 541 590 140
Fax: +420 541 590 124
www.nepa.cz
[email protected]
22