LINO EAF-250 Faucets | Maintenance Guide | Sloan

Repair Parts and Maintenance Guide
LINO EAF-250
PARTS LIST—EAF-250 FAUCETS
EAF-250 Series Faucet date code 1101 and
newer. Product revised to make spray head
vandal resistant without need for special spray.
EAF-15 only works on product date code 1052
and older.
Item
No.
1A.
1B.
2.
3A.
3B.
3C.
3D.
4.
5.
6.
7A.
7B.
8.
9.
10.
11.
—
12A.
12B.
13.
14 .
2
7A
3A
3B
3C
3D
8
7B
1A /1B
4
Code No.
0335019
0335018
0335027
0335012
Part No.
EAF-21-A
EAF-20-A
EAF-27
EAF-15
0335008
0335011
EAF-10
EAF-13
EAF-51
EAF-1003
EAF-1
EAF-9
EAF-1004
EAF-1005
EAF-1007
EAF-1008
EAF-2
ETF-312-A
SFP-11-A
ETF-510-A
SFP-22-A
EAF-35-A
EAF-40-A
0335029
3335018
0335000
0335007
0335019
3335020
3335022
3335023
0335001
3365468
0362011
3365024
3362022
3335035
3335046
5
12A /12B
Description
Faucet Sensor Assembly without i.q.-cliq ™
Faucet Sensor Assembly with i.q.-cliq ™
Cap
0.5 gpm (1.9 Lpm) VR Aerator Spray Head –
Pre 03/2011
2.2 gpm (8.3 Lpm) Aerator Spray Head
2.2 gpm (8.3 Lpm) Laminar Flow Spray Head
0.35 gpm (1.3 Lpm) Multi-Laminar Spray Head
Battery Replacement Kit
Faucet Mounting Kit
Strainer (Filter)
Mixer Handle Assembly and Cartridge
Handle Repair Kit
Handle Cap
13” (330 mm) Flexible Supply Hose
Solenoid
Trim Plate for 4” Centerset Sink
Use when needing 4” for EAF-35-A extension
Trim Plate for 8” Centerset Sink
Use when needing 8” for EAF-35-A extension
Faucet Extension Kit
2-1/4” Faucet Extension Kit. Raises faucet such
that outlet height complies with California Office of
Statewide Health Planning and Deveplopment
— = Not shown in illustration
i.q.-cliq™ SETTINGS
Function
9
Press Button
Continuous Run – 2 minute 1 time for 2 seconds
default setting (adjustable
from 1 – 20 minutes)
10
reset:
11
reset:
6
1 time or will reset
automatically after
2 minutes
2 times (double click)
14
187
5 short flashes followed by
periodic flashing
1 time or will reset
automatically after
2 minutes
Auto Set Range Adjustment 2 times (double click) and
then 1 time for 5 seconds
13
5 short flashes
5 short flashes followed
by 4 short flashes
Hand Hygiene
Temporary Off
LED Signal
Repair Parts and Maintenance Guide
LINO EAF-250
TROUBLESHOOTING GUIDE
OPERATION
1. Faucet does not function.
A. "Permanent Off" activated.
Press button on faucet throat one time.
As the user’s hands enter the beam’s
effective range, the beam is reflected
back into the sensor receiver and
activates the solenoid valve allowing
water to flow from the faucet. Water
will flow until the hands are removed
or until the faucet reaches its
automatic time out limit setting.
2. Faucet delivers water in an uncontrolled manner.
A. Faucet is not working properly.
Contact Sloan Technical Support at
1-888-SLOAN-14 (1-888-756-2614).
3. Faucet does not deliver any water when Sensor is activated.
INDICATOR: Solenoid valve produces an audible “CLICK.”
A. Water supply stop(s) closed.
Open water supply stop(s).
B. Water supply stop strainer(s) clogged.
Remove, clean, and reinstall water supply stop strainer(s).
Replace strainer(s) if required.
INDICATOR: Solenoid valve DOES NOT produce an audible “CLICK.”
A. Battery low (battery powered models).
Replace battery (refer to Battery Replacement on page 184).
CARE AND CLEANING INSTRUCTIONS
DO NOT use abrasive or chemical cleaners
(including chlorine bleach) to clean faucet that may
dull the luster and attack the chrome or special
decorative finishes. Use ONLY mild soap and water,
then wipe dry with clean cloth or towel.
While cleaning the bathroom tile, protect the
faucet from any splattering of cleaner. Acids and
cleaning fluids will discolor or remove chrome plating.
When assistance is required, please contact
Sloan Technical Support at: 1-888-SLOAN-14 (1-888-756-2614).
Hand Hygiene
4. Faucet delivers only a slow flow or dribble when
Sensor is activated.
A. Water supply stop(s) are partially closed.
Completely open water supply stop(s).
B. Water supply stop strainer(s) clogged.
Remove, clean, and reinstall water supply stop strainer(s).
Replace strainer(s) if required.
C. Aerator is clogged.
Remove, clean, and reinstall Aerator. Replace Aerator if required.
D. Faucet is not working properly.
Contact Sloan Technical Support at
1-888-SLOAN-14 (1-888-756-2614).
5. Faucet does not stop delivering water or continues to drip after
user is no longer detected.
A. Faucet is not working properly.
Contact Sloan Technical Support at
1-888-SLOAN-14 (1-888-756-2614).
6. LED indicator blinks when faucet is in use.
A. Battery low (battery powered models).
Replace battery (refer to Battery Replacement on page 184).
7. The water temperature is too hot or too cold on a faucet
connected to hot and cold supply lines.
A. Supply Stops are not adjusted properly.
Adjust Supply Stops.
B. For models with integral mixing valve – Mixing valve is set improperly
for the water temperature desired.
Rotate mixing valve handle clockwise to decrease water temperature or
counterclockwise to increase water temperature.