Bench Meters - Fisher Scientific Ireland

CyberScan 6000 Series
Bench Meters
• pH • pH FET • ORP • Ion • Conductivity • TDS • Salinity
• Resistivity • Dissolved Oxygen • BOD (OUR,SOUR)
Contents
Main Features
>> 04
Eutech CyberScan PCD 6500
>> 06
Eutech CyberScan PC 6500 & pH 6500
>> 07
Eutech CyberScan PC 6000 & pH 6000
>> 08
Eutech CyberScan CON 6000 & DO 6000
>> 09
Accessories
>> 10
Ordering Information
>> 12
Specification Tables
>> 14
page | 03
World’s First Windows® CE-Driven Full-Colour Touchscreen 21 CFR Part 11-Compliant Bench Meter
RS232 Communication Port: For data connectivity to 21 CFR Part 11 application software
Real-Time On-Screen
Graphing Function
Quick, convenient graphical analysis of data
on-the-spot – especially
useful in applications such
as titration
RJ45: Internet or network connection for quick online research and email access
SD Card Slot: For expanded data storage memory*
USB-B: Connect to PC for direct
file transfers
USB-A: Connect peripherals such as a
keyboard, mouse, printer or USB
flash drives*
IrDA: For wireless data transfer
Advanced Communications
Capabilities
Extensive communications
capabilities that allow
you to send data to any
computer in the world
directly from your meter!
Bar Code Scanning
For improved sample management
Audio: Audio output for multimedia files
* Memory card and flash drive available as separate accessories. See page 13 for more information.
Microsoft Windows
Interface
Familiar, intuitive and easy to use
Send Data To Any Computer In The World Directly From The Meter!
Windows® is a registered trademark of Microsoft Corporation in the United States and other countries
p
age | 04
Main
Features
• IP67 Waterproof
• Easy To Use
• 3-Year Warranty
• Quick, Stable & Accurate Results
• Full-Range Accuracy
• User-Customisation
Measure and View up to four
parameters at the same time with no cross-channel interference
Choose to View Data in 3 Different
Displays or switch between
parameters effortlessly with the press
of a button – meter presents data
in multi-channel, single-channel or
graphical analysis displays
Biggest Storage Space Offered in
the Industry!
Mega-memory stores up to 10,000
data sets (1,000 per parameter)
Password Protected Access and
Customization for up to Ten Users
10 password-protected logins with
settings and data stored separately,
so there is no need for meter
recalibration each time you switch user or electrode
Built For GLP-Compliance Research
Extensive data-logging capabilities
that allow optimal traceability of
data sets stamped with time, date
and sample IDs
Foolproof Navigation
Touchscreen colour display with
user-friendly icons, intelligent
prompts and context-specific “Help” screen to guide you through each operation
page | 05
Eutech CyberScan PCD 6500
CyberScan PCD 6500
pH / pH FET / ORP / Ion / Conductivity / TDS / Salinity / Resistivity /
Dissolved Oxygen / BOD (OUR, SOUR) / Temperature
Top-of-the-line, research-grade CyberScan PCD 6500 touchscreen meter measures and
displays up to four channels at one time. With 10 measurement parameters to choose
from, the PCD 6500 is engineered with advanced design that prevents cross-talk or
other interference. Plus, automatic five-day BOD testing capability with sample identity,
as well as extensive communications features that allow you to send your data to any
computer in the world via internet – directly from the meter!
• Measure and view up four channels at the same time with no cross channel interference
• Wide pH and mV measurement ranges
• Pre-programmed ISE-type selection
• ‘Direct/Indirect’, ‘Known Addition/Subtraction’ and ‘Analate Addition/Subtraction’ Ion measurement methods in ppm, % mg/mL and mol/mL
• Automatic five-day BOD testing, OUR and SOUR with EPA-compliant self-stirring probe
• Single-point and multi-point standardization for Conductivity, TDS, Salinity and Resistivity
measurements using 2-cell and 4-cell probes
• Built-in replatinising circuit – quick, replatinisation in less than 5 minutes
• Windows® CE-driven, full-colour touchscreen with user-friendly icons, prompt messages and context-specific trouble-shooting screens
Applications: • Pharmaceutical manufacturing • Research and lab course work • Forensic analysis
• Life sciences and medical researches • Environmental testing labs • Wastewater and drinking water
facilities • Food processing and beverage production
p
age | 06
CyberScan PC 6500
pH / pH FET / ORP / Ion / Conductivity / TDS / Salinity / Resistivity / Temperature
Simplify lab work with the multi-channel capabilities of Eutech’s CyberScan PC 6500.
Advanced design ensures that readings are unaffected by cross-talk or interference;
extensive communications functions allow you to send your data from meter to any
computer, in any method and format you want!
• Measure and view up three channels at the same time with no cross channel interference
• Wide pH and mV measurement ranges
• Pre-programmed ISE-type selection
• ‘Direct/Indirect’, ‘Known Addition/Subtraction’ and ‘Analate Addition/Subtraction’ Ion measurement methods in ppm, % mg/mL and mol/mL
• Single-point and multi-point standardization for Conductivity, TDS, Salinity and Resistivity
measurements using 2-cell and 4-cell probes
• Built-in replatinising circuit – quick, replatinisation in less than 5 minutes
• Windows® CE-driven, full-colour touchscreen with user-friendly icons, prompt messages and context-specific trouble-shooting screens
Applications: • Pharmaceutical manufacturing • Research and lab course work • Forensic analysis
• Life sciences and medical researches • Environmental testing labs • Wastewater and drinking water
facilities • Food processing and beverage production
Eutech CyberScan PC 6500 & pH 6500
CyberScan pH 6500
pH / pH FET / ORP / Ion / Temperature
Ion-selective electrode measurement has never been this easy. Harvesting the
sophisticated features of pH 6000, the CyberScan pH 6500 comes with dual-channel
capability, so there is no need to recalibrate every time you switch from pH to ISE
measurement. Advanced internet communications features allow you to send and
receive information directly in any format to any computer you want.
• Measure and view up two channels at the same time with no cross channel interference
• Accepts standard BNC pH glass electrodes and DIN pH ISFET electrodes – no need for adapters
• Wide pH and mV measurement ranges
• Pre-programmed ISE-type selection
• ‘Direct/Indirect’, ‘Known Addition/Subtraction’ and ‘Analate Addition/Subtraction’ Ion measurement methods in ppm, % mg/mL and mol/mL
• Built-in replatinising circuit – quick replatinisation in less than 5 minutes
• Windows® CE-driven, full-colour touchscreen with user-friendly icons, prompt messages and context-specific trouble-shooting screens
Applications: • Pharmaceutical manufacturing • Research and lab course work • Forensic analysis
• Life sciences and medical researches • Environmental testing labs • Wastewater and drinking water
facilities • Food processing and beverage production
page | 07
CyberScan PC 6000
pH / pH FET / ORP / Conductivity / TDS / Salinity / Resistivity / Temperature
The CyberScan PC 6000 simplifies intricate lab work! For quick, accurate measurements
of pH and conductivity, simply place pH and conductivity cells into the same solution
– no fear of cross-talk between the two parameters. Measure conductivity, resistivity,
TDS and salinity with 2-cell probes or versatile 4-cell probes for greater linearity over
a wide range. The PC 6000 is compatible with a wide array of Eutech conductivity cells
and features selectable cell constants that allows you to measure from ultrapure water
to brine and concentrated solutions
• Measure and view up two channels at the same time with no cross channel interference
• Wide pH and mV measurement ranges
• Single-point and multi-point standardization for Conductivity, TDS, Salinity and Resistivity
measurements using 2-cell and 4-cell probes
• Built-in replatinising circuit – quick, replatinisation in less than 5 minutes
• Windows® CE-driven, full-colour touchscreen with user-friendly icons, prompt messages and context-specific trouble-shooting screens
Applications: • Pharmaceutical manufacturing • Research and lab course work • Forensic analysis
• Life sciences and medical researches • Environmental testing labs • Wastewater and drinking water
facilities • Food processing and beverage production
Eutech CyberScan PC 6000 & pH 6000
CyberScan pH 6000
pH / pH FET / ORP / Temperature
The Eutech CyberScan 6000 offers easy, single-channel operation for pH or ORP
measurements without compromising on performance or features. With extensive
communications capabilities, now you can choose to send data directly with your meter
in any way you want, to any computer in the world!
• Auto-calibrates with up to five pH buffers from three standard sets and fifteen different buffers. Meter also accepts custom buffers and manual calibration
• Wide pH and mV measurement ranges
• Windows® CE-driven, full-colour touchscreen with user-friendly icons, prompt messages and context-specific trouble-shooting screens
Applications: • Pharmaceutical manufacturing • Research and lab course work • Forensic analysis
• Life sciences and medical researches • Environmental testing labs • Wastewater and drinking water
facilities • Food processing and beverage production
p
age | 08
CyberScan CON 6000
Conductivity / TDS / Salinity / Resistivity / Temperature
Measure conductivity, total dissolved solids, salinity, resistivity and temperature, all
with one powerful meter!
The versatile CyberScan CON 6000 is compatible with a variety of Eutech conductivity
cells, and accepts simple 2-cell probes or versatile 4-cell probes for greater linearity over
a broad range of measurements. Selectable cell constants allow you to measure from
ultrapure water to brines and other concentrated solutions.
• Single-point and multi-point standardization for Conductivity, Resistivity, TDS, Salinity measurements using 2-cell and 4-cell probes
• Built-in replatinising circuit – quick, replatinisation in less than 5 minutes
• Extensive setup screens allow customization according to your measurement needs
• Windows® CE-driven, full-colour touchscreen with user-friendly icons, prompt messages and context-specific trouble-shooting screens
Applications: • Pharmaceutical manufacturing • Research and lab course work • Forensic analysis
• Life sciences and medical researches • Environmental testing labs • Wastewater and drinking water
facilities • Food processing and beverage production
Eutech CyberScan CON 6000 & DO 6000
CyberScan DO 6000
Dissolved Oxygen / BOD (OUR, SOUR) / Temperature
The CyberScan DO 6000 is powerful yet easy to use with its touchscreen simplicity and
versatility. Simply enter seed value along with other relevant BOD data, and let your DO
6000 do the rest. With on-screen prompts and self-stirring probe, analysis with BOD,
SOUR and OUR methods are a breeze. Correction of temperature, salinity and barometric
pressure is automatic, giving you unparallel accuracy over a large measurement range.
• Automatic five-day BOD testing with sample ID with self-stirring probe that complies with EPA method requirements
• Wide DO measurement range from 0 to 60 mg/L and 0 to 600 % saturation
• Extensive setup screens allow customization according to your measurement needs
• Windows® CE-driven, full-colour touchscreen with user-friendly icons, prompt messages and context-specific trouble-shooting screens
Applications: • Pharmaceutical manufacturing • Research and lab course work • Forensic analysis
• Life sciences and medical researches • Environmental testing labs • Wastewater and drinking water
facilities • Food processing and beverage production
page | 09
Eutech CyberScan
6000 Series Bench Accessories
| CyberComm 6000 | From the manufacturer of the world’s first Windows® CE-driven, full-colour,
touchscreen premium research-grade meters comes CyberComm 6000 – a powerful, comprehensive
data management software designed in compliance with FDA’s 21 CFR Part 11 regulations. With the
CyberComm 6000 software, you can now expand the memory space of your meter to your personal
computer’s hard-disk and allow the management of multiple projects under each individual ID login.
Password security protects each ID login from tampering and accidental data deletion, yet allowing IDs
in the meter to share common calibration settings.
View and Backup Detailed Activity Log for Auditing
Easy to Use
The main window of the CyberComm 6000 is designed to look identical to the screen of the CyberScan
6000 meter display. Upon connecting the meter to your computer and launching the software, you can
continue working on the meter through the screen of your computer as you would on the meter.
Other Advantages of the Software:
• Records every detail down to each single click executed, and generates a full audit-trail report on
demand, accessible only by the Administrator
• Generates comprehensive reports of your project in print-friendly format, or simply translate your
data into Microsoft Excel format with a mouse-click
• Capture snap-shots of your graphs in action while projects are running
• Automatically detects electrodes and calibration solutions used during projects (user-assigned serial numbers)
• Automatically prints electronic signature with each report print-out generated
Share and Use Existing
Standardization Available in your CyberComm
• Allows real-time data-logging and real-time graph, right from the comforts of your computer
The CyberComm 6000 is sold separately. Each software CD comes with a software license number to
match the serial number of your instrument.
Please quote instruments’ serial numbers when placing orders.
Snap Shot and Real-Time Graphing Capabilities
CyberComm 6000
21 CFR Part 11 Application Software
p
age | 10
| Electrodes | Eutech offers an extensive selection of epoxy and glass-body electrodes for a wide range
of parameters and applications. Combination designs are convenient and require no separate sensing
and reference half-cell electrodes.
| Buffer & Calibration Solutions (480 ml) | Eutech Buffers and Calibration Solutions are available in
packs of 480 ml durable plastic bottles – economical and convenient for laboratory use.
(MSDS and COA can be downloaded under “Support” at http://www.eutechinst.com)
Electrodes
| Calibration Sachets (20 x 20 ml Per Box) | Economical NIST traceable sachets offer quick, accurate
and convenient calibration. Simply insert electrode into sachet pack, calibrate, rinse and discard sachet
– no separate container needed!
| Standard SD Memory Card (256 MB) | One tiny card stores up to 258 MB worth of data – great for
quick data transfer and built to last with an operating shock rating of 2000 Gs.
| USB Flash Drive (256 MB) | Carry your data anywhere with these small, compact and highly
portable USB flash drives. No software installation required – flash drives are Hi-Speed USB 2.0 certified,
so all you need to do is to plug into your CyberScan 6000 series meter or computer to copy and
transfer data.
pH Buffer Solutions
USB Flash Drive
pH Buffer Sachets
Standard SD Memory Card
page | 11
Eutech CyberScan 6000 Series Bench
Ordering Information
6000 Series
6500 Series
Meters
Model Order Code
Part No.
PCD
ECPCD650044S 01X374106
PCD
ECPCD650042S 01X374107
PC
ECPC650043S 01X374005
PC
ECPC650040S 01X374006
pH
ECPH650042S 01X373705
pH
ECPH650040S 01X373706
Description
Color Touchscreen CyberScan PCD 6500 4 Channel pH/pH FET/ORP/Ion/
Conductivity/Resistivity/TDS/Salinity/DO/BOD/OUR/SOUR RS232, USB, IrDA Meter with pH Electrode EC620130, Conductivity Electrode EC620165,
ATC Electrode EC62019, DO/BOD Electrode EC620SSP, Electrode Holder & SMPS Power Adapter
Color Touchscreen CyberScan PCD 6500 4 Channel pH/pH FET/ORP/Ion/
Conductivity/Resistivity/TDS/Salinity/DO/BOD/OUR/SOUR RS232, USB, IrDA Meter with DO/BOD Electrode EC620SSP, Electrode Holder & SMPS Power Adapter
Color Touchscreen CyberScan PC 6500 3 Channel pH/pH FET/ORP/Ion/
Conductivity/Resistivity/TDS/Salinity RS232, USB, IrDA Meter with pH Electrode EC620130, Conductivity Electrode EC620165, ATC Electrode EC62019, Electrode Holder & SMPS Power Adapter
Color Touchscreen CyberScan PC 6500 3 Channel pH/pH FET/ORP/Ion/
Conductivity/Resistivity/TDS/Salinity RS232, USB, IrDA Meter with Electrode
Holder & SMPS Power Adapter
Color Touchscreen CyberScan pH 6500 2 Channel pH/pH FET/ORP/Ion RS232, USB, IrDA Meter with pH Electrode EC620130, ATC Electrode EC62019, Electrode Holder & SMPS Power Adapter
Color Touchscreen CyberScan pH 6500 2 Channel pH/pH FET/ORP/Ion RS232, USB, IrDA Meter with Electrode Holder & SMPS Power Adapter
PC
ECPC600043S 01X373605
PC
ECPC600040S 01X373606
pH
ECPH600042S 01X373505
pH
ECPH600040S 01X373506
CON ECCON600043S 01X373805
CON ECCON600040S 01X373806
DO
ECDO600042 01X373905
Color Touchscreen CyberScan PC 6000 2 Channel pH/pH FET/ORP/
Conductivity/Resistivity/TDS/Salinity RS232, USB, IrDA Meter with pH Electrode EC620130, Conductivity Electrode EC620165, ATC Electrode EC62019, Electrode Holder & SMPS Power Adapter
Color Touchscreen CyberScan PC 6000 2 Channel pH/pH FET/ORP/
Conductivity/Resistivity/TDS/Salinity RS232, USB, IrDA Meter with Electrode
Holder & SMPS Power Adapter
Color Touchscreen CyberScan pH 6000 pH/pH FET/ORP RS232, USB, IrDA Meter with pH Electrode EC620130, ATC Electrode EC62019, Electrode Holder & SMPS Power Adapter
Color Touchscreen CyberScan pH 6000 pH/pH FET/ORP RS232, USB, IrDA Meter with Electrode Holder & SMPS Power Adapter
Color Touchscreen CyberScan Con 6000 Conductivity/Resistivity/TDS/
Salinity RS232, USB, IrDA Meter with Conductivity Electrode EC620165, Electrode Holder & SMPS Power Adapter
Color Touchscreen CyberScan Con 6000 Conductivity/Resistivity/TDS/
Salinity RS232, USB, IrDA Meter with Electrode Holder & SMPS Power Adapter
Color Touchscreen CyberScan DO 6000 DO/BOD/OUR/SOUR RS232, USB, IrDA Meter with DO/BOD Electrode EC620SSP & SMPS Power Adapter Meter Plays Media Files
p
age | 12
Electrodes & Accessories
Model Order Code
Part No.
pH
EC620130
01X218972
pH
EC62019
01X306504
pH
93X218980
93X218980
pH
93X218981
93X218981
pH
93X218982
93X218982
pH
93X218983
93X218983
ISE
ECNH30101B 93X035100
ISE
ECNH40301B 93X218736
ISE
ECFO0301B
93X218723
ISE
ECNO30301B 93X218739
ISE
ECNA0201B
93X218714
ISE
ECCLO0301B
93X218717
Description
Glass Body, Refillable, Open Pore (10 ml Electrolyte 620-430 Included)
ATC Probe, 1 m Cable
CONEFET pH Electrode, Epoxy Body, DIN Connector, Ø10 mm x 200 mm, 1.5 m Cable
CUPFET pH Electrode, Epoxy Body, DIN Connector, Ø10 mm x 200 mm, 1.5 m Cable
SURFET pH Electrode, Epoxy Body, DIN Connector, Ø10 mm x 200 mm, 1.5 m Cable
LANCEFET pH Electrode, Epoxy Body, DIN Connector, Ø10 mm x 200 mm, 1.5 m Cable
CON EC620165
93X219046
CON EC620100
93X219060
CON EC620101
93X219059
CON EC620102
93X219061
CON EC620163
93X219045
CON EC620164
93X219057
CON EC620166
93X219047
Epoxy-Body 4-Ring Conductivity Electrode, Cell Constant K=1.0, DIN Connector, 1 m Cable
Epoxy-Body 2-Ring Conductivity Electrode, Cell Constant K=1.0, DIN Connector, 1 m Cable Epoxy-Body 2-Ring Conductivity Electrode, Cell Constant K=0.1, DIN Connector, 1 m Cable Epoxy-Body 2-Ring Conductivity Electrode, Cell Constant K=10, DIN Connector, 1 m Cable Glass-Body 4-Ring Conductivity Electrode, Cell Constant K=1.0, DIN Connector, 1 m Cable Glass-Body 4-Ring Conductivity Electrode, Cell Constant K=10.0, DIN Connector, 1 m Cable
Epoxy-Body 4-Ring Conductivity Electrode, Cell Constant K=10.0, DIN Connector, 1 m Cable DO
EC620SSP
Ammonia Gas Sensor
Ammonium Combination Epoxy
Fluoride Combination Epoxy
Nitrate Combination Epoxy
Sodium Combination Glass
Chloride Combination Epoxy
01X295704 DO/BOD Electrode with Self-Stirring Mechanism, 1 m Cable
Others ECDAS6000
01X415501
Others ECPHELSTDC 01X081600
Others ECCA02M09F09 30X219503
Others 60X030128
60X030128
Others 01X420001
01X420001
Others 01X419901
01X419901
CyberComm 6000 21 CFR Part 11 Compliant 6000 Series Application Software
Electrode Stand with Swivel Arm
RS232 Communication Cable: 9-Pin Male to 9-Pin Female Connector, 1 m Cable
Adapter, SMPS, 100/240 VAC, 9 V, 3.3 A, CENTRE -ve, with 2-Pin Power Cord
USB Flash Drive, 256 MB
SD Memory Card, 256 MB, Sandisk
Touchscreen Keypad for Easy Data Input
Direct Printing of Data During Measurement
page | 13
Eutech CyberScan 6000 Series Bench
Specification Tables
| Warrant y | Eu te c h I n s t r u m e n t s
provides three years of warranty against
manufacturing defects for meters, and six
months for electrodes.
Eutech reserves the right to make changes, improvements and modifications to products shown.
PCD 6500
PC 6500
PC 6000
Multi-Parameter
Bench Meters
Range
Resolution
Accuracy
No. Of Calibration Points
pH
mV
Relative mV
Ion
-2.000 to 20.000 pH
0.1, 0.01, 0.001 pH
±0.1, 0.01, 0.002 pH + 1 LSD
5
USA: 2.00, 4.00, 7.00, 10.00, 12.00
NIST: 1.68, 4.01, 6.86, 9.18, 12.45
Euro: 1.00, 3.00, 6.00, 8.00, 10.00, 13.00
pH Buffer Sets
Automatic Buffer Recognition
Manual Buffer Recognition
FET
Range
Resolution
Accuracy
Range
Resolution
Accuracy
No. Of Calibration Points
Methods
Range
Resolution
Accuracy
No. Of Calibration Points
Incremental Methods
Yes
Yes
Yes
±2000.0 mV
0.1 mV
±0.2 mV
±2000.0 mV
0.1 mV
±0.2 mV
1
Set default reading to zero or set relative mV
1 x 10-6 to 9.99 x 1010
2, 3, 4 digits
±0.17 % full scale (monovalent)
±0.34 % full scale (divalent)
5
KA, KS, AA, SS
Conductivity
Accuracy
.. to 200.0 ppm
200.0 to 2000 ppm
2.000 to 20.00 ppt
20.00 to 200.00 ppt
(depending on TDS factor)
0.001, 0.01, 0.1 ppm
0.001, 0.01, 0.1 ppt
0.5 % full scale + 1 LSD
Range
TDS
Resolution
Accuracy
Salinity
.. to 0.094 ppt
0.094 to 1.000 ppt
1.0 to 11.50 ppt
11.50 to 90.00 ppt
Resolution
Accuracy
Resolution
Accuracy
4 (1 per range) auto
(Conductivity only)
4 (1 per range) manual
No. Of Calibration Points
p
age | 14
.. to 0.094 ppt
0.094 to 1.000 ppt
1.0 to 11.50 ppt
11.50 to 90.00 ppt
.. to 20.00 kΩ
20.00 kΩ to 200.0 kΩ
200.0 kΩ to 2.000 mΩ
2.000 mΩ to 100.0 mΩ
0.1, 0.01, 0.001 kΩ
0.01, 0.001 mΩ
0.5 % full scale + 1 LSD
Resistivity
Dissolved
Oxygen
.. to 0.094 ppt
0.094 to 1.000 ppt
1.0 to 11.50 ppt
11.50 to 90.00 ppt
0.1, 0.01, 0.001 ppt
0.5 % full scale + 1 LSD
Range
Cell Constant
Temperature Coefficient (per ºC)
Normalisation Temperature
Range
Resolution
Accuracy
No. Of Calibration Points
–
–
0.001, 0.01, 0.1 µS/cm,
0.001, 0.01, 0.1 mS/cm
0.5 % full scale + 1 LSD
Resolution
Range
–
.. to 200.0 µS/cm
200.0 µS/cm to 2.000 mS/cm
2.000 to 20.00 mS/cm
20.00 to 500.0 mS/cm
Range
Conductivity
–
–
0.1, 1.0, 10.0
0.000 to 10.000 %
15.0 to 30.0
0 to 60 mg/L or ppm (0 to 1272 mbar)
0.01 mg/L or ppm (0.1 mbar)
±0.1 + 1 LSD
2 (0 mg/L, 8.26 mg/L)
–
–
–
–
PCD 6500
PC 6500
PC 6000
Multi-Parameter
Bench Meters
Range
Resolution
Accuracy
No. Of Calibration Points
Range
Barometric
Pressure
Resolution
Correction
Accuracy
Range
Salinity
Correction
Resolution
Range
Temperature Resolution
Accuracy
No. Of Channels
Display
LCD
Keypad Controls
BNC, ATC,
DIN (FET)
DIN
(Conductivity)
Input/Output DIN (Dissolved
Oxygen)
RS232, USB-B,
USB-A, RJ45,
SD Reader
Temperature Compensation
Electrical Requirement
Output From PSU
Line Voltage Tolerance
Input Impedance
Auto Read
Meter
Features
Memory Points
Programmable
Data Storage
Programmable
Memory
Data Output
Print Interval
Programmable
Alarm
Operating
Temperature
Operating
Humidity
Maximum
Operating
Operating
Conditions
Altitude
Installation
Category
Pollution
Category Degree
Power Requirements
Meter
Dimensions (LxWxH); Weight
Boxed
% Saturation
Of Oxygen
0 to 600 %
0.1 %
±0.1 % + 1 LSD
2 (0 %, 100 %)
450 to 825 mmHg
1 mmHg
±1 mmHg + 1 LSD
.. to 45 ppt
0.1 ppt
4
–
–
–
–
–
–
–
–
–
5.0 to +105.0 ºC
0.1 ºC
±0.2 ºC
3
640 x 480 x digit ; 4½” x 6” ; extensive help screen
Context specific touchscreen
2
Yes
Yes
Yes
–
Yes
ATC/MTC (-5 to 100 °C) (Meter)
115 V / 60 Hz, 230 V / 50 Hz
9 V DC, 3.3 A center negative
±10 %
>10 (12)
Yes
1000 data sets per parameter
Store on stable, time, manual
Timed or logged data
3 to 86400 s
Yes
5 to 45 °C
5 to 80 % non-condensing
2000 m
II
2
9 V DC adapter, 3.3 A (100/240 VAC, SMPS)
16.5 x 23.5 x 8.9 cm ; 1100 g
49 x 28 x 16 cm ; 3700 g
<< Lab Course Work
<< Food Processing
<< Wastewater
page | 15
pH 6500
pH 6000
pH
Bench Meters
Range
Resolution
Accuracy
No. Of Calibration Points
pH
mV
Relative mV
Ion
Temperature
USA: 2.00, 4.00, 7.00, 10.00, 12.00
NIST: 1.68, 4.01, 6.86, 9.18, 12.45
Euro: 1.00, 3.00, 6.00, 8.00, 10.00, 13.00
pH Buffer Sets
Automatic Buffer Recognition
Manual Buffer Recognition
FET
Range
Resolution
Accuracy
Range
Resolution
Accuracy
No. Of Calibration Points
Methods
Range
Resolution
No. Of Calibration Points
Incremental Methods
Range
Resolution
Accuracy
No. Of Channels
LCD
Keypad Controls
BNC, ATC,
DIN (FET)
1 x 10-6 to 9.99 x 1010
2, 3, 4 digits
–
–
–
5
KA, KS, AA, SS
–
–
5.0 to +105.0 ºC
0.1 ºC
±0.2 ºC
1
640 x 480 x digit ;
4½” x 6” ; extensive help screen
Context specific touchscreen
Yes
Input/Output RS232, USB-B,
USB-A, RJ45,
SD Reader
Yes
Temperature Compensation
Electrical Requirement
Output From PSU
Line Voltage Tolerance
Input Impedance
Auto Read
Memory Points
ATC/MTC (-5 to 100 °C) (Meter)
115 V / 60 Hz, 230 V / 50 Hz
9 V DC, 3.3 A center negative
±10 %
>10 (12)
Yes
1000 data sets per parameter
Programmable
Data Storage
Store on stable, time, manual
Programmable
Data Output
Timed or logged data
Memory
Print Interval
Programmable
Alarm
Operating
Temperature
Operating
Conditions
Dimensions (LxWxH); Weight
3 to 86400 s
Yes
5 to 45 °C
Operating
Humidity
5 to 80 % non-condensing
Maximum
Operating
Altitude
2000 m
Installation
Category
II
Pollution
Category Degree
2
Power Requirements
p
age | 16
Yes
Yes
Yes
±2000.0 mV
0.1 mV
±0.2 mV
±2000.0 mV
0.1 mV
±0.2 mV
1
Set default reading to zero or set relative mV
±0.17 % full scale (monovalent)
±0.34 % full scale (divalent)
Accuracy
Display
Meter
Features
-2.000 to 20.000 pH
0.1, 0.01, 0.001 pH
±0.1, 0.01, 0.002 pH + 1 LSD
5
Meter
Boxed
9 V DC adapter, 3.3 A (100/240 VAC, SMPS)
16.5 x 23.5 x 8.9 cm ; 1100 g
49 x 28 x 16 cm ; 3700 g
CON 6000
Conductivity
Bench Meter
Range
Conductivity
Resolution
Accuracy
Range
TDS
Resolution
Accuracy
Conductivity
Range
Salinity
Resolution
Accuracy
Range
Resistivity
Resolution
Accuracy
No. Of Calibration Points
Cell Constant
Temperature Coefficient (per ºC)
Normalisation Temperature
Range
Temperature Resolution
Accuracy
No. Of Channels
Display
LCD
Keypad Controls
DIN
(Conductivity)
Input/Output RS232, USB-B,
USB-A, RJ45,
SD Reader
Temperature Compensation
Electrical Requirement
Output From PSU
Line Voltage Tolerance
Input Impedance
Auto Read
Memory Points
Meter
Programmable
Features
Data Storage
Programmable
Memory
Data Output
Print Interval
Programmable
Alarm
Operating
Temperature
Operating
Humidity
Maximum
Operating
Operating
Conditions
Altitude
Installation
Category
Pollution
Category Degree
Power Requirements
Meter
Dimensions (LxWxH); Weight
Boxed
.. to 200.0 µS/cm
200.0 µS/cm to 2.000 mS/cm
2.000 to 20.00 mS/cm
20.00 to 500.0 mS/cm
0.001, 0.01, 0.1 µS/cm,
0.001, 0.01, 0.1 mS/cm
0.5 % full scale + 1 LSD
.. to 200.0 ppm
200.0 to 2000 ppm
2.000 to 20.00 ppt
20.00 to 200.00 ppt
(depending on TDS factor)
0.001, 0.01, 0.1 ppm
0.001, 0.01, 0.1 ppt
0.5 % full scale + 1 LSD
.. to 0.094 ppt
0.094 to 1.000 ppt
1.0 to 11.50 ppt
8.0 11.50 to 90.00 ppt
0.1, 0.01, 0.001 ppt
0.5 % full scale + 1 LSD
.. to 20.00 kΩ
20.00 kΩ to 200.0 kΩ
200.0 kΩ to 2.000 mΩ
2.000 mΩ to 100.0 mΩ
0.1, 0.01, 0.001 kΩ
0.01, 0.001 mΩ
0.5 % full scale + 1 LSD
4 (1 per range) auto (Conductivity only)
4 (1 per range) manual
0.1, 1.0, 10.0
0.000 to 10.000 %
15.0 to 30.0
5.0 to +105.0 ºC
0.1 ºC
±0.2 ºC
1
640 x 480 x digit ; 4½” x 6” ; extensive help screen
Context specific touchscreen
Yes
Yes
ATC/MTC (-5 to 100 °C) (Meter)
115 V / 60 Hz, 230 V / 50 Hz
9 V DC, 3.3 A center negative
±10 %
>10 (12)
Yes
1000 data sets per parameter
Store on stable, time, manual
Timed or logged data
3 to 86400 s
Yes
5 to 45 °C
5 to 80 % non-condensing
2000 m
II
2
9 V DC adapter, 3.3 A (100/240 VAC, SMPS)
16.5 x 23.5 x 8.9 cm ; 1100 g
49 x 28 x 16 cm ; 3700 g
page | 17
DO 6000
DO
Bench Meter
Range
Resolution
Accuracy
No. Of Calibration Points
Range
% Saturation Resolution
Of Oxygen
Accuracy
No. Of Calibration Points
Range
Barometric
Pressure
Resolution
Correction
Accuracy
Range
Salinity
Correction
Resolution
Range
Temperature Resolution
Accuracy
No. Of Channels
Display
LCD
Keypad Controls
DIN (Dissolved
Oxygen)
Input/Output RS232, USB-B,
USB-A, RJ45,
SD Reader
Temperature Compensation
Electrical Requirement
Output From PSU
Line Voltage Tolerance
Input Impedance
Auto Read
Memory Points
Meter
Programmable
Features
Data Storage
Programmable
Memory
Data Output
Print Interval
Programmable
Alarm
Operating
Temperature
Operating
Humidity
Maximum
Operating
Operating
Conditions
Altitude
Installation
Category
Pollution
Category Degree
Power Requirements
Meter
Dimensions (LxWxH); Weight
Boxed
Dissolved
Oxygen
<< Beverage Production
>> Life Science & Medical Researches
p
age | 18
0 to 60 mg/L or ppm (0 to 1272 mbar)
0.01 mg/L or ppm (0.1 mbar)
±0.1 + 1 LSD
2 (0 mg/L, 8.26 mg/L)
0 to 600 %
0.1 %
±0.1 % + 1 LSD
2 (0 %, 100 %)
450 to 825 mmHg
1 mmHg
±1 mmHg + 1 LSD
.. to 45 ppt
0.1 ppt
5.0 to +46.0 ºC
0.1 ºC
±0.2 ºC
1
640 x 480 x digit ; 4½” x 6” ; extensive help screen
Context specific touchscreen
Yes
Yes
ATC/MTC (-5 to 100 °C) (Meter)
115 V / 60 Hz, 230 V / 50 Hz
9 V DC, 3.3 A center negative
±10 %
>10 (12)
Yes
1000 data sets per parameter
Store on stable, time, manual
Timed or logged data
3 to 86400 s
Yes
5 to 45 °C
5 to 80 % non-condensing
2000 m
II
2
9 V DC adapter, 3.3 A (100/240 VAC, SMPS)
16.5 x 23.5 x 8.9 cm ; 1100 g
49 x 28 x 16 cm ; 3700 g
Research Bench Meters
For Electrochemistry
page | 19
Eutech Instruments manufactures a comprehensive range of laboratory and
field instrumentation for water analysis. Eutech Instruments also produces
on-line process instruments for water quality monitoring and control. Innovative
products from Eutech include:
| World-Wide Sales and Service Support | Eutech provides world-wide
sales and service support for all its products through its network of
international distributors. Contact us at marketing@eutechinst.com for
details of your nearest distributor.
Part of Thermo Fisher Scientific Inc.
Awarded in 2001 & 2003
2006 & 2007
BEN 08X233799 04/07 Rev 1
Distributed by: