This pellet boiler is approved for the operation of an open or closed circuit hot water heating system
with a permissible operating pressure of up to 3 bars and a maximum flow line temperature of
95◦C.
It is not permitted to operate the pellet boiler without a return flow booster. The operation of the
return flow booster is to be monitored. A 4-way mixing valve is sufficient as a return flow booster on
systems with a buffer tank.
The boilers supplied by Janfire are stationary units that comply with the WEEE Directive. The
electrical and electronic components contained in the boilers do not fall within the remit of this
directive and will therefore not be taken back by Janfire. Please take these components to the
recycling depot.
We do not assume any liability for any malfunctions resulting from the use of non-genuine Janfire
Components.
This particularly applies to control units, external materials handling equipment and fuel pipes from
other manufacturers. We also do not assume any liability for operational difficulties resulting from
inadequate hydraulic and/or exhaust gas systems. We reserve the right to make technical changes.
Permissible fuel
It is only permitted to operate this pellet boiler with fuels that comply with the Federal Emission
Control Ordinance (wood pellets manufactured from natural wood).
Permissible pellets have a diameter of 6mm or 10mm. The pellets must comply with the EN-Plus
standard or the PVA standard (Austrian Pellet Association). The fine fraction (proportion of pellets
with a length
of less than 10mm) is not permitted to exceed 8% in the pellet hopper. The volume density must be
less than 0.75kg/l. Other fuels, in particular pellets that contain recycled materials, may not be
used.
The specified cleaning interval applies to pellets that comply with the EN-Plus standard.
For reasons of operational safety and environmental protection the use of fuels other than
pellets that comply with the EN-Plus or EN 14961-2 Class A1 standards is not permissible.
32580002_ EN_ver4
 Janfire 2014
2(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
Contents
1.1
1.2
1.3
1.4
1.5
General .........................................................................................................4
Conventions ...................................................................................................4
Safety Instructions for Installation and Service ...............................................5
CE declaration ...............................................................................................5
Chimney Connection ......................................................................................5
2
Technical Data ..............................................................................................7
3
3.1
3.2
3.3
Boiler Maintenance .................................................................................... 12
Ash Removal and Sweeping ........................................................................ 12
Sweeping Handle ......................................................................................... 13
Emptying the Ashtray ................................................................................... 14
4
4.1
4.1.1
4.1.2
4.1.3
4.1.4
4.1.5
Boiler Control Panel Boiler ........................................................................ 14
Buttons and Controls.................................................................................... 15
Setting of Operating Temperature ................................................................ 16
Start the Pellet Burner .................................................................................. 16
Stop the Pellet Burner from the boiler........................................................... 16
Start the Circulation Pump ........................................................................... 16
Stop the Circulation Pump............................................................................ 16
5
Operational Description............................................................................. 18
5.2
5.3
Modulated power regulation...................................................................... 20
Gliding boiler temperature in function of outdoor temperature ...................... 21
6
6.1
6.2
6.4
6.5
6.6
6.7
6.8
6.9
6.10
6.11
6.12
Burner Maintenance ................................................................................... 22
Menu System ............................................................................................... 23
Target temperature ...................................................................................... 25
Volume Adjustment ...................................................................................... 25
Energy Value ............................................................................................... 26
Choice of Effect Value .................................................................................. 26
Starting the Burner ....................................................................................... 26
Starting the Burner after the Installation ....................................................... 27
Stopping the Burner ..................................................................................... 28
Pellets Filling .............................................................................................. 30
Cleaning the Burner .................................................................................... 30
Cleaning the Dosage Auger ........................................................................ 32
7
7.2
7.3
7.4
7.5
7.5
7.6
7.7
Trouble-Shooting ....................................................................................... 33
Red warning light shine -The Burner has stopped ........................................ 35
Yellow Control Lamp; Burner Running ......................................................... 39
To low Effect from the Burner ...................................................................... 40
The Burner Display is of ............................................................................... 41
Fuses ....................................................................................................... 42
Adjusting the Capacity Sensor ..................................................................... 43
Electrical Connection Plan ........................................................................... 44
32580002_ EN_ver4
 Janfire 2014
3(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
1
1.1
Safety Information
General
The safety information is based on a risk analysis that has been undertaken in accordance with the
directions in relevant EU directives in order to meet the European
CE marking standards.
In practice, the pellet boiler does not convey any risks during operation.
Read through the safety information before you carry out any maintenance on the boiler. Always
follow the safety instructions when you carry out maintenance work. Follow the safety instructions
on the warning labels!
Installation, operation, service and other procedures must only be carried out by trained and
qualified personnel and in accordance with applicable standards.
Note Always follow these instructions during maintenance of the boiler.
Note For reasons of personal and operational safety: Use only spare parts that are manufactured
and approved by Janfire AB.
1.2
Conventions
The following conventions are used in these instructions:
DANGER!
The text DANGER! is used when there is a risk of personal injury or death.
WARNING!
The text WARNING! is used when there is a risk of damage to the product, the equipment, the
control panel etc.
CAUTION!
The text CAUTION! is used when there is a risk of system failure, interruption to operation,
disruption etc.
The above warning texts are used in a hierarchical order. The text DANGER! also includes the
possibility of the occurrence of incidents that are represented by WARNING! or CAUTION!
32580002_ EN_ver4
 Janfire 2014
4(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
1.3
Safety Instructions for Installation and Service
All electrical installation and servicing must be carried out by qualified personnel in accordance with
applicable standards and regulations.
All heating, ventilation and sanitation installation and servicing must be carried out by qualified
personnel in accordance with applicable standards and regulations.
All sweeping must be carried out by qualified personnel in accordance with applicable standards
and regulations.
DANGER
High Voltage
inside
this equipment
DANGER
Risk of burns
Note The free space around the Janfire pellet boiler should be in accordance with BBR-94 (SWE)
and local regulations (council planning department).
The boiler room should meet the requirements of the fire authorities. Contact a qualified local
chimney sweeping contractor.
The boiler is equipped with a safety cut-out that prevents operation of the burner with the door
open.
1.4
CE declaration
If the unit is used in combinations other than those tested, then Janfire AB can not guarantee
conformity with the EU directive.
Please consult your heating installer about the precise system set-up.
1.5
Chimney Connection
The exhaust gas duct to the chimney should be as short as possible, without any bends and
installed at a slight incline. The connection to the chimney should have an aerodynamic design that
curves upward.
The connector joining the furnace and the chimney must comply with EN 1856-2:2004 and have
the required identification marking (CE). In accordance with EN 1856-2:2004 non-insulated
32580002_ EN_ver4
 Janfire 2014
5(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
connectors must be kept at least 40 cm away from combustible components. We recommend the
use of insulated connectors.
Calculated chimney diameters that are smaller than the flue gas connections of the boiler are not
permissible. See technical data.
Please note: Please note that the low exhaust temperatures occurring during prolonged operation
may mean that it is necessary to fit a moisture-resistant chimney.
Before connecting the pellet boiler to an existing chimney, subject it to a chimney calculation or
obtain a chimney report. Before commencing with the installation it is essential to obtain the
approval of your local master chimney sweeper.
An insufficient draft or a dirty flue gas system will be detected by the burner via the temperature
sensors. The display unit of the burner control unit will then display the fault message „flue draft
insufficient“. Should this occur, the control lamp will switch to yellow and thereby show that the
burner is in emergency operation mode. The display unit will then alternately show the above fault
message and the fault message „reduced output“. If the problem cannot be handled by reducing
the output of the burner and dangerous temperatures occur at the sensors, the burner will be
switched off once the upper temperature limit is
Chimney connection
The exhaust gas duct to the chimney should be as short as possible, without any bends and
installed at a slight incline. The connection to the chimney should have an aerodynamic design that
curves upward. The connector joining the furnace and the chimney must comply with EN 18562:2004 and have the required identification marking (CE). In accordance with EN 1856-2:2004 noninsulated connectors must be kept at least 40 cm away from combustible components. We
recommend the use of insulated connectors.
32580002_ EN_ver4
 Janfire 2014
6(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
2
Technical Data
Janfire Integral typ 25 Pellet Boiler
Power
230 V AC ± 10 %, 50 Hz
Load
3 VA
Stand by power
2W
Measurement accuracy of water
temperature sensor
0– 100°C ± 1°C
Minimum return water temperature
55° C
Output
23 kW
Boiler class according EN 303-5 4.4.2
5
Relay output
5 A 250 V AC
Fuse
6.3 A T
Water volume
180 litres
Waterside resistance 10/20K
25,3/14,1 mbar
Maximum operation pressure
3 bar
Ash/fire box
100 litres
Weight
280 kg
Boiler Type
Not Condensing under pressure controlled
Flue connection
Backwards Ø 145 mm
Convection part
Vertical tubes
Operation thermostat
Adjustable intervals up to 15°C
Flue gas thermometer
Option
Use of Sweeping
Automatic controlled
Shunt/Mixing Valve
Mounted together with hot water flange
OBS Option
Hot water
High efficiency heat exchange coil Ø 22 mm
L=11m, OBS Option
Control panel
Digital display with surface mounted switches
Safety cut-out
Mounted on the top of the door
Required Draft in furnace
10 Pascal
Exhaust temperature nominal/min load
145/73° C
Exhaust mass flue nominal/min load
0,013/0,05 kg/sec
Combustion period
Cleaning manual after use of 6 tonnes pellets
Fuel
Wood Pellets EN Plus size Ø 6-12 mm
Noise emission
61 db
32580002_ EN_ver4
 Janfire 2014
7(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
Accessories
A
Automatic sweeping
Periodic controlled
Placed on the left side.
B
Automatic ash outflow
Placed on the left or the right side.
C
Location for Electric
heater
Option up to 9 kW
D
Boiler Operator Panel
E
Burner Operator Panel
A
D
C
B
E
Figure 1 Automatic sweeping and ash outflow
32580002_ EN_ver4
 Janfire 2014
8(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
Figure 2 Janfire Pellet Boiler dimensions General
32580002_ EN_ver4
 Janfire 2014
9(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
The Janfire pellet boiler is designed to burn wood pellets in a safe, easy-to-use and
environmentally friendly way. The boiler has ten vertical tubes which effectively cool down the flue
gases and through thermal convection raise the temperature of the water. The tubes are also
equipped with retarders. The boiler is equipped with a large door. The door has a prepared hole
suitable for installation of the burner. When the door is opened the burner remains on the door.
This makes it very easy to clean the combustion chamber and burner. The door is also equipped
with a safety cut-out which stops the burner when the door is opened.
Recommended boiler temperature:
Winter: 85 ˚C +/- 3 ˚C
Summer: 83 ˚C +/- 3 ˚C
Note Pellet quality EN 14961-2 Class A1 is recommended
32580002_ EN_ver4
 Janfire 2014
10(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
Water mixer valve with
drive
Inbuilt Exhaust fan
House, Fan Option
Hatch for access to the tubes
Operator panel
Soot sweeping mechanism
Domestic Hot Water Coil,
Option
Location for Electric
Coil, Option
Pellets Burner
Ash bottom auger screw
Bottom auger Drive
Figure 3 Overview
32580002_ EN_ver4
 Janfire 2014
11(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
3
Boiler Maintenance
During normal use (6-8 tonnes per year) of pellets of EN 14961-2 class A1 the maximum interval
for cleaning the boiler is 10-12 months.
3.1
Ash Removal and Sweeping
1. Stop the burner, see burner instructions.
2. Wait for approximately 30 minutes until all the pellets are no longer glowing.
3. Open the door of the combustion chamber. Remove the baffle plate (see Figures)
DANGER
Risk of burns
Note The boiler and burner can still be hot.
4. Clean out the ash. The Janfire ash can makes the job easier.
5. Open the upper hatch (see Figure 3 Overview) above the tubes and take out the spirals.
32580002_ EN_ver4
 Janfire 2014
12(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
6. Use the sweeping brush to clean the ten tubes.
7. Reassemble the spirals and screw down the upper hatch.
CAUTION
Breakdown
Note Do not forget to clean the boiler flue so that soot does not prevent the smoke from going out
into the chimney.
3.2
Sweeping Handle
Sweeping starts automatically and is controlled by the boiler thermostat and a timer. Sweeping
frequency is set as standard 1 minute every hour.
If the boiler is not equipped with automatic handle sweeping then you should manually use the
sweeping handle (OBS Option) at least once a week. Pull the handle quickly 3-5 times on each
occasion.
32580002_ EN_ver4
 Janfire 2014
13(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
3.3
Emptying the Ashtray
After the burning of about 1.5 t of pellets (depends strongly on the quality of pellets used), the ash
tray must be emptied. Wearing of protective gloves is recommended.
Ensure the hot ashes are not put into a container that either contains combustible materials or that
is combustible itself.
4
Boiler Control Panel Boiler
The switch panel controls the boiler pump and the burner.
During operation the following can be read on the display of the control panel:
•
Water temperature
Actual Temperature
Figure 4 Control Panel
32580002_ EN_ver4
Thermostat
 Janfire 2014
P2
P1
14(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
P3
Figure 5 Temperature limiter
Figure 6 Ash timer
4.1
Buttons and Controls
Button
Push
P1
Start/Stop the pellet burner
P2
Start/top the circulation
pump
P3
Temperature limiter
Thermostat
Change set point of water
temperature
Ash timer
Setting for on time off time
ash removal and tube
sweeping
Info
Adjusted from factory. No need for adjustment
Actual
32580002_ EN_ver4
 Janfire 2014
15(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
Button
Push
Info
Temperature
4.1.1
Setting of Operating Temperature
Turn the thermostat knob to the desired temperature normaly between 60-90 ° C If
the boiler temperature is below the desired value, the burner will be allowed to start
4.1.2
Start the Pellet Burner
Push the P1 button in On possition, The burner will illuminate and start if the boiler thermostat is
demanding heat..
4.1.3
Stop the Pellet Burner from the boiler.
Push the P1 button to off possition. The Burner stops emmidiately
4.1.4
Start the Circulation Pump
Push the ON button P2 and the the pump will start.
4.1.5
Stop the Circulation Pump
Push the OFF button P2.
32580002_ EN_ver4
 Janfire 2014
16(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
Figure 7 Dimension drawing NH-burner
32580002_ EN_ver4
 Janfire 2014
17(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
5
5.1
Operational Description
General operation description
An external auger feeds pellets from an pellet store via flexible drope tube and in to a receptacle in
the burner (internal storage). An internal dosage auger then feeds the pellets to a drop shaft where
they fall freely into the combustion chamber; this eliminates the possibility of reverse combustion.
A fan feeds the burner with primary and secondary air. On its way to the burning cup the air cools
heat-exposed parts of the burner effectively warming up the incoming primary and secondary air. A
specific amount of air is fed into the combustion cup for primary and secondary combustion. The
ignition coil preheats the air for automatic ignition. The thermometer (flame guard) notes when the
pellets have ignited. If ignition does not succeed then the burning cup is automatically cleaned and
a new attempt is made. If ignition still does not successful then the burner is shut down.
If the airflow is insufficient then the hot flu gases will rise in the drop shaft. The burner control will
register this rise in temperature with an temperature sensor and the burner will compensate by
reducing the effect, thus eliminating the risk for reverse combustion. When this takes place the
control lamp changes colour to yellow to indicate that the system is running in backup level and
”Low chimney flow” will appear on the display screen.
If the temperature drops to normal levels the burner control will return to normal operation but will
continue to illuminate the yellow light warning of draft problems in the boiler or chimney.
If the temperature in the drop shaft still rises and reaches the highest limit, then the burner will shut
down.. The control lamp will turn red and “Overheated” will appear on the display screen.
The burner output can be set in the burner control operator menu and is determined by the desired
level of heat required, set between 6kW and 25kW (factory settings and permissible min/max level
can be adjusted by the installer) Burner output is adjusted in 1kW steps and is governed by the
burner thermostat sensor. In addition an optional pilot operation will continue to maintain
combustion until further heat is in demand.
The pellet feed rate at a given output is automatically adjusted when the lambda sensor is installed.
Otherwise the volume weight of the pellets is entered into the burner control in order to allow the
burner to adjust the pellet feed rate. The volume weight is typically 675 g / litre with energy content
of 4.8 kWh / kg.
In order to secure power and combustion in use of pellets with another volume weight or energy,
change value of the volume and energy and pellets.
Optimal burner performance can also be controlled with the (optional) installation of temperature
sensor PT100, allowing the burner to automatically modulate up or down in relation to the heat
demand. Alternative to using the modulation function the burner will operate between min and max
temperature settings, heating until the desired temperature has been reached at the boiler
thermostat.
32580002_ EN_ver4
 Janfire 2014
18(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
High quality pellets produce high efficiency and effect. High quality pellets are solid wood pellets 610 mm with little sawdust. Moisture levels should be no higher than 12%, ash content no higher
than 1% weight, and energy content should be about 4,7 and 5,0 kWh/kg. Make sure you see a
content declaration for the pellets on delivery..
The burner has a patented moving grate in the bottom of the combustion cup which scrapes away
soot and ash residue into the boilers firebox. This ensures the combustion grate holes are kept
clean to maintain the burner performance. The burner automatically cleans itself according to a
signal from the boilers thermostat or from pre-programmed intervals (use of pellet) Additionally the
boiler tubes are swept clean according to the thermostate and the time period set in the boiler
control.
Thermo switch in the upper part of drop shaft breaks power to burner if the temperature
there exceeds 70°C. Manual reset through breaking power to burner, wait until
burner cools down and connect the power again.
A micro switch prevents the
burner from operating when
detached from the boiler
bulk head.
Figure 8 Micro switch
The moving grate of the combustion cup scrapes away slag and waste material, feeding it into the
boilers firebox according to a signal from the boilers thermostat or from pre-programmed intervals
(number of fillings)
The moving grate in
operational position
The moving grate in
cleaning position
Figure 9 Moving grate
32580002_ EN_ver4
 Janfire 2014
19(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
Support
(Accessories)
Engine gearbox
external auger
Boiler
External auger
Drop tube
Capacity sensor
Internal pellets storage
Dosage auger
Drop shaft
Burning chamber
Inlet
Figure 10. Function description
5.2 Modulated power regulation
Contact for
temperature
sensors
In order to be able to use the modulation function a Pt100 sensor connection is provided on the
side of the burner..
The aim of this function is to save on fuel consumption and enhance operational efficiency while
reducing the number of cycles per hour. Janfire's intelligent control system monitors the heating
system demand trends and modulates the boiler output accordingly. This makes for quick and
smooth response at maximum output when the demand is high and progressively drops and settles
on low output when the heat load is nearly fulfilled. temperature decreases in the boiler.
Difference of objectives temperature is set at +7 ° C to the regulation should have a little larger
area to work in. It is at this temperature field burner to work best in. If or when the temperature
comes up for the higher limit (when the heat consumption is lower than the Burner's lowest power)
breaking the operation and the burner goes into standby or maintenance.
32580002_ EN_ver4
 Janfire 2014
20(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
The burner will restart the combustion operation again when the lower temperature limit (3C lower
than target temperature) has been reached. Boiler temperature hysteresis is 10C from maximum
target temperature (-3 C to +7C from target)
When using the mody modulation function please set the boiler operating temperature above the
+7C maximum level.
If the PT100 temperature sensor is not connected to the burners control unit then the control will
revert to the boiler thermostat and the system will operate using the set permanent set output level.
If there is no boiler thermostat then breaking the operation and alarm "ERROR " are available.
5.3
Gliding boiler temperature in function of outdoor temperature
This function regulates the temperature in the boiler depending on outside temperature as follows:
Warmer outdoors lower boiler temperature and vice versa. Colder outdoor temperature create
higher boiler temperature.
In this way boiler temperature is adapted to outdoor temperature fluctuations during the day and
during season cycles.
With an outside temperature sensor type Pt 100 linked to the burner, the temperature is regulated
in the boiler as follows:
+20° C or higher out----60° C boiler temperature
-20° C or less absent -----90° C boiler temperature
For outdoor temperatures between the specified limits obtained a sliding boiler temperature target
value so, for example, at 0 ° C is target 75 ° C.
73 ° C [72 → 75 ← 82]
In the above example:
-- 73 - current boiler temperature
-- 75-calculated target temperature (gliding target value)
-- 72 - temperature thermostat switched on at the current target temperature (this is 3 ° C for target
value)
-- 82 - temperature of the thermostat off at the current target temperature (7° C above target value)
The outdoor temperature average value is calculated by measuring the outdoor temperature over 5
minute intervals. This is compared with the the previous value and once considered the boiler
temperature is adjusted. Boiler temperature target value is adjusted 1C per interval whether is is
measured greater tolerance than 1C.
When the estimated target temperature approaching 90 ° C, the temperature limit for the
thermostat off is adjusted to a maximum of 92 ° C. It is only +2 ° C above at 90 ° C although it is set
to +7 ° C above target temperature thus the control system ensures optimal performance and
protects the boiler from overheating .
Identical level of control features exist for the low level limit which is restricted to 55C.
32580002_ EN_ver4
 Janfire 2014
21(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
6
Burner Maintenance
Thanks to a new patented technique the Janfire NH Pellets burner has the least need of
maintenance of all pellets burners on the market. The burner can run for 6 months at a time without
maintenance (applicable for burners mounted on Janfire boilers). When mounted on an existing
boiler the ash handling varies depending on the size of the boilers ash container.
CAUTION
Breakdown
For optimal and safe operation it is important that all adjustments of the burner’s operational
parameters are correct. We recommend that you sign a service agreement with your retailer.
NOTE Regularly check that the gasket around the burner is not damaged.
32580002_ EN_ver4
 Janfire 2014
22(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
6.1 Menu System
A
B
C
D
E
Figure 11 Menu system
Janfire NH Control panel
A
Control lamp: Green = Normal, Yellow = Warning, Red = Error
B
Start/Stop A press will stop all activities in the burner (complete), a
new press and the burner is continuing where it left off.
C
Reduce value
D
Increase value
E
Scroll menu (quick press). Save/confirm value (press for three seconds)
Adjustment of the contrast in the display is made with the "+" and "-" buttons. The change can be
made only when the display shows the status and operation information.
By pressing and hold down the "+" button to be increased and by "-" reduced the contrast.
In order to save the new setting, press and hold the "menu" button for a few
second, until the confirmation appears: "saving in mind."
NOTE: When not pressing any buttons for 1 minutes, display light tones down and is lit again through
pressing some off buttons
NOTE: When not pressing any buttons for 5 minutes, the status mode will automatically appear in
the display.
Menu System for the Janfire NH”
One press on the ”on/off” button stops all activities in the burner. Press again and it continues
where it left off.
32580002_ EN_ver4
 Janfire 2014
23(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
On start up status will be shown in the display. When not pressing any buttons for 5 minutes, the
status mode will appear in the display automatically.
Every press of the menu button scrolls through the menu list below.
Adjustments are done using the “-“ and “+” buttons and must be saved by pressing the “menu”
button for 3 seconds (“save to memory” appears on the display”).
Status: This shows the present status information; it can show errors or running status etc.
Boiler temperature 73 ° C <72 → 75 ← 82> Shown only on modulating regulation is elected
at boiler temperature over 40 ° C. (In the example: 73 - the current temp, 75 – target value;
72 - thermostats switched on, 82 off the thermostat). Target value amended by + / - and
saved.
Pellets use: Displays pellet consumption: total and changeable. Reset by pressing and
holding down the "menu" button until the value is reset.
Choose effect level: Here you can choose what effect you want to use. Any amendment
must be saved.
Ash scraping: Ash scrape every 18 kg (x, xxxkg). Here is determined how much the pellets should
be consumed before the automatic ash scraping performed. As an aside, displayed up-to-date
pellets consumption after last cleaning
Volume settings: The correct level can be supplied by your pellets supplier or by weighing.
Energy level: Your pellets supplier can supply the correct level.
Automatic start with start-up: Choose if the burner should automatically start when the power is
turn on. This function should always be “on” if the burner can start after a power cut.
Running down: Is used when you wish to remove the ash from the boiler. Running down function
runs in three sequences, begin cooling, burning cup scraping and then combustion stop. Pressing
the “menu” button for more than 3 seconds activates this..
NOTE This function is shown only when the burner is running.
Manuell feeding: Press and hold down the “+” button and the dosage auger will run until the
button is released.
NOTE This function is shown only when the burner is stopped.
Manual external auger: Press and hold down the “+” button and the dosage auger will run until
the button is released or when the level meter in the filling tube is effected.
NOTE This function is shown only when the burner is stopped.
32580002_ EN_ver4
 Janfire 2014
24(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
6.2 Target temperature
Boiler temperature appears only if modulating control is activated, and boiler temperature is over
40 ° C.
73 ° C <72 → 75 ← 82>
In the above example:
-- 73 - current boiler temperature
-- 75 –target temperature (preferred boiler temperature – target value)
-- 72 - temperature thermostat switched on (this is 3 ° C below target value)
-- 82 - temperature switched the thermostat off (this is the 7 ° C above target value)
To change target temperature Scroll through the menu until you come to "boiler temperature" and
change "-" and the "+" and save by pressing the "menu" of three seconds.
Note that in the amendment of the desired boiler temperature limits to the thermostat and off (socalled hysteresis - in the example +7 ° C / -3 ° C) is included.
Other limits and hysteresis can be set by the installer.
6.3 Pellets counter
We show pellet consumption in kg: total and reset to zero. Reset by pressing and holding down the
"menu" button until the value is reset.
6.4
Volume Adjustment
Volume weight:
XXX g/l
32580002_ EN_ver4
 Janfire 2014
25(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
To achieve the best combustion and least exhaust a correct level for the volume weight of the
pellets is needed. The correct level can be supplied by your pellets supplier or by weighing.
675 g/l is the standard level, which is the average weight per liter pellets. When adjusting the levels
the dosage time is also changed (normally 1 sec.) to compensate for and discrepancies and to
ensure good combustion.
To change: Scroll in the menu until you come to “volume weight xxx g/l” and change with “-“ and
“+”. To save the new level by pressing and holding down the “menu” button for 3 seconds.
Weighing: Fill a 1-liter container with pellets and weight it on a scale. Take away the containers
weight.
6.5
Energy Value
To achieve the best combustion and least exhaust a correct energy value for the pellets is needed.
Your pellets supplier can supply the correct level.
4,80 kWh/kg is the standard level, which is the average energy per kilogram pellets.
To change: Scroll in the menu until you come to “volume weight xxx g/l” and change with “-“ and
“+”. To save the new level by pressing and holding down the “menu” button for 3 seconds.
6.6
Choice of Effect Value
Press and scroll through the “menu” button until you come to “Choose effect level xx kW
By pressing “+” or “-“ buttons you can choose increase or decrease the power between the effect
levels. To save the new level; press and hold down the “menu” button for 3 seconds.
The effect can be selected between 6 and 15 kW. This is the standard setting.
Limits for min and max power levels can be changed between 3 and 23 kW . This is carried out by
the installation engineer and in consultation with the customer depending on the need for heating,
boiler type, size of the chimney etc.
6.7 Starting the Burner
1. Place the burner into the boiler and lock it in place on both sides
WARNING
Product damage
32580002_ EN_ver4
 Janfire 2014
26(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
NOTE The burner should be fitted securely so that no embers or smoke are released. A non-airtight
connection can lead to a worse combustion and function.
2. Check that there are sufficient pellets in the external storage. The pellets level should not be
lower than the external augers inlet.
3. Check that the power cables between the burner and boiler and between the boiler and the
external auger are connected. Control that the drop tube between the external motor and the
burner is secure.
4. Switch on main power.
NOTE The main power switch is usually located on the wall next to the boiler or by the entrance to the boiler
room.
5. Switch on the power to the burner (the switch is on the boiler) and the boiler will start
automatically at the 12 kW effect level (Auto start at restart)
6. The change to the desired effect: Scroll the “menu” button until you come to “Choose effect xx
kW”. Change the value be pressing the “+” and “-“ buttons. Save the new level by pressing and
holding down the “menu” button for 3 seconds, “Saved to memory” will appear on the display
screen.
OBS! The next time the burner is started, it will run in the last saved power level
7. To achieve a good combustion with low exhaust the values of the pellets volume weight and
energy value has to be correct. The correct level can be supplied by your pellets supplier or by
weighing. To change; scroll the “menu” button and change the value be pressing the “+” and ““buttons. Save the new value by pressing and holding down the “menu” button for 3 seconds
If the boilers thermostat is on, then the internal storage is filled (approx. 2 min.) if the pellets level is
below the sensor. The burning cut is then cleaned. The start sequence then begins. Pellets are
feed in, the ignition spiral warms up and the fan starts. The start sequence is pre-programmed to
deliver a fast ignition and exhaust levels as low as possible. The start-up runs for about 10 minutes
after which the chosen effect level begins.
6.8 Starting the Burner after the Installation
NOTE It is important that when starting up for the first time that the internal storage and the dosage auger are
full with pellets.
1. Switch on the power to the burner. After 2 minutes the external screw starts. The feeding stops
after 2 minutes. If the internal storage is not filled within 2 minutes press the “ON/OFF” button
and the auger will continue to feed. Continue this process until the correct level is reached.
When the internal storage is full a sensor stops the external auger.
The external auger can be used manually: Scroll the menu until you come to “manual external
auger”, then press and hold the “+” button to start the motor. Fill until the burners internal
storage is full. The motor will stop when the “+” button is released or when the internal storage
sensor is activated. Since the automatic system will normally “Auto start at restart” and will try
32580002_ EN_ver4
 Janfire 2014
27(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
to continue press the “ON/OFF” button to stop the burner. “Stopped manually” will appear on
the display screen. Manual pellets’ feeding is only possible when the system is off
2. Since the internal storage has been filled the internal feeding auger must also be filled. This
can be done manually by scrolling the “menu” button until you come to “Manual feeding”, then
press and hold the “+” button to start the motor, let it run until pellets start to fall into the burning
cup. The motor will stop when the “+” button is released.
3. Press the “ON/OFF” button to start the burner
“Keep Alive” (kindling) burning is automatically selected from the thermostat stand by time is less
than 1 hour (the standard setting). In Keep alive goes burner in a sharply lowered power (0.6 kW),
which is burning up and running and enable quick power increase after thermostats switched on.
At first OF on the thermostat after the start is not used maintenance. OF time (shorter or longer
than 1 hour) determines whether the next OF maintenance should be used or not.
6.9
Stopping the Burner
The burner can be stopped in the following ways:
NOTE “Shut Down” in the user menu is recommended stop if not the stop caused by danger.
” Shut down” in the menu when it is time to remove the ash the burner should be cooled and
scraped. This function is only activated when the burner is running by scrolling though the menu
until you comes to “Shut down”. Press and hold down the “Menu” button for 3 seconds to activate.
Control that the fan has stopped and that the scraping is complete. This can take up to 10 minutes
depending on the programme chosen. “Manually stopped” will appear on the display screen and
the control lamp will turn red.
Switch off the main power if you wish the burner to remain shut down. This will ensure that the
burner will not start accidentally at a power failure.
Press the “ON/OFF” button to stop the burner”
“Stopped manually” will appear on the display screen. All of the burner’s functions will stop. This is
standby. Pressing the “ON/OFF” button again restarts the burner at the point when it was stopped.
(It can continue in standby mode or cool down, scrap clean and begin a new start up depending on
how long it was turned off). Switch off the main power if you wish the burner to remain shut down.
NOTE Use the “ON/OFF” button for stop only in emergency situation and let the burner remain in the boiler
until it cool down. This to avoid injuries and overheating of the burner
32580002_ EN_ver4
 Janfire 2014
28(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
NOTE Do not switch off the main power until the fan has stopped.
NOTE Always switch off the power at the mains when the burner is to be off for a longer period or when
servicing the burner. The main power switch is usually located on the wall next to the boiler or by the
entrance to the boiler room.
32580002_ EN_ver4
 Janfire 2014
29(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
6.10 Pellets Filling
The external auger can only feed the pellets to the burner if the external storage level is above the
external augers inlet.
NOTE Add pellets to the external storage when needed.
DANGER
Rotating parts
NOTE Do not touch the dosage auger or the external augers in- or outlet when the external motor is
connected.
6.11
Cleaning the Burner
1. Stop the burner according to the instructions in chapter 4.9
2. Wait for 30 minutes until all glowing pellets has burnt out.
3. Disconnect the burner and roll it away from the boiler.
DANGER
Risk of burns
NOTE The burner and the burning chamber can still be hot.
4. Lift the plate out with a pair of insulated pliers or wear protective gloves.
32580002_ EN_ver4
 Janfire 2014
30(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
5. Clean the plate and the burning chamber carefully. Use a vacuum cleaner together with
the Janfire ash container (accessory).
6.
Pour about 0.5 dl water on the scraper and burner cup. Water dissolves hard slag on
the scraper. Let it dissolve for a few minutes and then wipe with a cloth.
CAUTION
Breakdown
NOTE The plate’s surface must rest tight on the burning chamber surface. All dirt between the surfaces must
be removed.
7. Remove ash from the boiler. Open all doors to reach all convection areas and flue gas
pipes. The “Janfire ash container” makes this procedure easier.
NOTE Do not forget to clean around the smoke pipe so that no ash prevents the smoke to reach the
chimney. Put the plate back in place.
32580002_ EN_ver4
 Janfire 2014
31(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
6.12
Cleaning the Dosage Auger
1. Switch off the power to the burner.
NOTE The main power switch is usually located on the wall next to the boiler or by the entrance to the boiler
room.
2. Remove the lid from the drop shaft and clean the dosage auger with a screwdriver.
Use a hammer (if necessary) to remove stuck pellets.
DANGER
Rotating parts
NOTE Do not touch the dosage auger or the external augers in- or outlet when the external motor is
operational.
3. Switch on the main power.
4. Press the ”on/off” button to stop the burner.
5. Start feeding away pellets remainders by pressing the ”menu” button until you reach
”Manuel feeding” in the menu and press the”+” button to start the motor. Continue
feeding until you see good quality pellets in the auger.
32580002_ EN_ver4
 Janfire 2014
32(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
7
7.1
Trouble-Shooting
Display status texts
JANFIRE AB
Version 3.02 UK
Start text at power up, shows program version
Startup underway
Try 1 3 min
Shows that burner lightning up, and time elapsed
Running 12,00kW
Run mode, actual power level
Waiting…
Burner has shut down, waiting for thermostat
Maintenance
mm:ss
Shows time elapsed in maintenance mode
Defaults sets
Release buttons
Default values have successfully being set
Saving in
memory
Heating up
Step 1 mm:ss
Setting is being saved
Transition to run mode from maintenance, a manual stop or
after power failure.
Manual stop
Waiting.
When burner is stopped with “on/off” button
Shutdown
activated…
Burner is shut down via function in User menu, ash scraper
will be activated when burner cooled down.
Now shut down
waiting
Wait! Cooling
down burner
Burner is shut down.
Cooling burner bowl to reach limit in service menu 48
Waiting for
pellets!
Filling up internal pellets storage
Limit. run
Running with reduced power, poor chimney flow
32580002_ EN_ver4
 Janfire 2014
33(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
ERROR MESSAGES
PROBLEM
A warning. Is shown when something is wrong and burner is taking actions to
compensate this..
ERROR
An alarm message. Burner is stopped due to an error that burner could not
compensate for.
!!! Problem !!!
Ashscraper
Maximum time elapsed for ash scraper. Scrape cycle
finished successfully on new attempt
!!! ERROR !!!
Ashscraper
Ash scraper did not success scrape cycle despite several
attempts
!!! Problem !!!
Startsequence
Flame guard did not activate in time, new start attempt.
Warning is reset after successful start.
!!! Probblem !!!
Fan stopped
!!! ERROR !!!
Fan stopped
Tachometer can’t sense fan rotation. Any other activity will
be stopped until fan runs properly. Warning will be reset
when fan starts
No rotation signal from fan despite several restart tries.
!!!Problem !!!
Flameguard trip.
Flameguard tripped during run mode, low temperatures I
burner bowl. One start attempt will be made.
!!! Problem !!!
Low chimney flow
Temperature to high in drop shaft, “service menu 49”
Burner power level will be reduced until temperature
decreases. Warning has to be acknowledged by pressing
“on/off” twice” (Stop and start).
!! Problem !!!
Service needed
Pellets consumption has passed setting in “service menu
59” Call your Janfire installer for accurate service.
!!! ERROR !!!
Not cooled down
Cooling did not succeed within 20 minutes
!!! ERROR !!!
External feed
Internal pellets storage not filled within time period
!!! ERROR !!!
Drop shaft temperature exceeds maximum level
32580002_ EN_ver4
 Janfire 2014
34(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
Overheated
!!! ERROR !!!
Indicated an error in the outgoing electricity supply to extern
auger, internal auger or heating coil.
"Electronics Fault"
!!! ERROR !!!
Temp. senor
Indicated an error in the Temperature sensors (burner bowl or
drop shaft sensors) has an unstable value.
7.2 Red warning light shine -The Burner has stopped
Event
Probable cause
Action
The green lamp on the control
panel has gone out and the
burner has no voltage.
The fuse has blown.
Reset the fuse (see chapter5).
The burner will start automatically.
Should the fuse blow again contact your
Janfire retailer or a service technician.
The safety thermostat for the boiler
has been turned off.
Reset the safety thermostat (see the
operating instructions for the boiler)
The control lamp shows red
”!!! ERROR !!! hot burner”
Insufficient low-pressure caused by
over heated burner.
Check the draught.
Turn off the main switch
Clean the boiler and flue pipes according to
instructions.
Inspect and clean the chimney.
The feeding of the external
auger has stopped.
The control lamp shows red
”!!! ERROR !!! External”
The external storage is empty.
Fill the external storage with pellets.
The drop tube is stuck with pellets.
The level of the capacity sensor has
been altered.
Adjust the capacity sensor
The drop tube between the external
augers outlet and the burner’s inlet
has come loose.
Mount the drop tube and start the burner
according to instructions.
Strange objects in the auger (gravel,
cloth etc) which prevents the auger
from rotating.
Knock carefully on the auger with a
rubber/plastic hammer while you run the
motor manually until the object comes
loose and the auger rotates correctly again.
Should this not work the auger may have to
be dismounted. Contact your Janfire
retailer.
32580002_ EN_ver4
 Janfire 2014
35(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
Event
Control lamp turns red
”!!! ERROR !!! burner
disconnected”
Ash scraper is stuck
”!!! ERROR !!! ash scraper”
Ash scrape is stuck
32580002_ EN_ver4
Probable cause
Action
Hollowing or crater in the external
pellets storage.
Level the pellets in the external storage.
The pellets get stuck in the tube and
does not reach the burner.
The tube between the external auger
and the burner is to loose or the tube
angle is insufficient.
Check if the pellets are stuck at the
external augers outlet. Clean if necessary.
Stretch the tube, increase the angle of the
tube.
The burner has been disconnected
from the boiler
Connect the burner to the boiler.
Press ”ON/OFF” to start.
Faulty circuit breaker or incorrectly
adjusted circuit breaker.
Adjust or replace. Contact your Janfire
retailer for assistance.
The ash in the burning chamber
sinters to hard slag. Insufficient pellet
quality.
Remove the slag from the burning
chamber.
Lower the amount of feedings for ash
scraping.
Press ”ON/OFF” to start
Ignition is not working. Pellets may
be stuck between the scraper and
the burning chamber
Remove pieces of pellets from the burning
chamber.
Press ”ON/OFF” to start
If this problem occurs again contact your
Janfire retailer.
NOTE: Do not switch the scraper to lose it, with the hammer or the like.
In this way, damage to the gearbox occur
The ash sintered in burner cup to a
tough cookie. Pellets of poor quality.
Remove the slag from burner cup
Reduce the number of kg before ach
cleaning.
Press "on / off" to start
Black deposits of tar and carbon on
the scraper do it difficult to scrape
clean. The cause of incorrect set
pellets volume with poor combustion
as a result.
Scrape clean scraper manually with a knife,
chisel or the like.
Weigh pellet and set the correct value for
volume weight.
If the error repeats itself contact the dealer
for a control of combustion.
Dark grey slag on scraper caused by
high temperatures in burner cup. .
Pour about 0.5 dl water on the scraper and
burner cup . Water dissolves hard coatings
on the scraper. Let it ache for a few minutes
and then wipe with a cloth. Start the burner.
The ignition is not working. Unburned
pellets have wedges itself between
the scraper and burner cup
Remove stuck pellet from burner cup.
Press the "ON / OFF 'to start
If the error repeats itself, contact the service
technician
 Janfire 2014
36(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
Event
Probable cause
Action
Ash scrape position switch is badly
adjusted or broken. Ash scrape runs
back and forth without activating
position switch.
Call your service technicians to fix the error.
Ignition has not occurred or a faulty
ignition coil.
The level of pellet in the burning chamber
is to low. Check that pellets are fed to the
dosage auger before the start.
Contact your Janfire retailer or a service
technician to replace the ignition coil.
Bad quality pellet.
Change to better quality pellet.
Insufficient low-pressure in the boiler
can cause disturbance in augers due
to tar (sticky) This will make the
dosage auger stop.
Check values for the boilers low-pressure.
(carried out by Janfire retailer or a service
technician).
Strange objects in the pellets or
damp pellets causing the dosage
auger to stop .
Remove the damp pellets or the strange
object .
The fan is not correctly adjusted.
Contact your Janfire retailer or a service
technician.
The control lamp turns red
”!!! ERROR !!! Fan”
The fan is faulty.
Mechanical obstacle that prevents
the fan from operating.
Contact your Janfire retailer or a service
technician.
The display shows
"Electronic Fault”
The software has detected an
irregular condition.
1.) Turn system OFF at main system s
switch. Turn back on after 10 seconds.
If error still persists, go to the following
steps.
2.) Check connection to external auger.
3.) Check the fuse to heating coil
4.) If fault continues, Contact your Janfire
retailer or a service technician.
The control lamp turns red
!! ERROR !! Temp Sensor
Temperature sensors (burner bowl or
drop shaft sensors) has an unstable
value.
1.) Turn system OFF at main switch. Turn
back on after 10 seconds.
If error still persists, Contact your Janfire
retailer or a service technician.
The display shows
!!! ERROR !!! Bad thermostat
Control box receives reading from
boiler sensor outside accepted range
(0 – 120 °C ).
1.) Check boiler sensor connections.
2.) If error still persists, Contact your
Janfire retailer or a service technician.
Flame guard has been
activated:
The control lamp turns red.
”!!! ERROR !!! Ignition”
32580002_ EN_ver4
 Janfire 2014
37(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
Event
Probable cause
Action
If display completely blank/no
read-out
Tripped manual reset high limit or
low water cut-off; bad fuse or.
incorrect boiler sensor value.
1.) Check fuses.
2.) Check if main switch is in ON position
3.) Check if burner connector is plugged
in. in system (See boiler manual). If
4.) Check if error light on low-water cutoff
is on. If so, press reset and top off
water problem persists, call MESys
trained service technician.
5.) Check manual reset high limit. Press
button. If burner operates, wait and
check. If problem persists, Contact
your Janfire retailer or a service
technician.
6.) PT100 sensor for boiler water sensing
may be defective. Contact your Janfire
retailer or a service technician.
32580002_ EN_ver4
 Janfire 2014
38(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
7.3 Yellow Control Lamp; Burner Running
Event
Probable cause
Action
Control lamp turns yellow
The burner still running.
The display shows:
”reduced effect” or ”running”
Insufficient draught or ash or soot
between the boiler and smoke pipe
or foreign objects in the chimney that
prevents the smoke from getting out.
The lamp indicates that the burner is
trying to compensate (reduced
effect” in the display) or has tried to
compensate insufficient draught by
reducing the effect.
The lamp will remain yellow until the
burner has been restarted to indicate
that there has been a problem with
insufficient draught.
Turn off the main switch. Clean the boiler
and the flue pipes according to
instructions. Inspect and clean the
chimney. If necessary check the draught.
32580002_ EN_ver4
 Janfire 2014
39(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
7.4 To low Effect from the Burner
Event
Probable cause
Action
The burner does not create
enough effect.
The choosen level of effect is to
low.
Increase the level of effect (see
chapter 0).
Insufficient pellets quality.
Contact your pellets distributor
and demand a quality
declaration. Adjust the volume
(see chapter 0).
To high or to low low-pressure in
the boiler.
Check by holding a match in front
of a small opening on the boiler
(for instance open a door
slightly). The flame shall lean
towards the boiler but not burn
out. Contact your Janfire retailer
or a service technician if you are
uncertain.
The adjusted values for the boiler
or the burner are not correct.
Check the protocol from the
installation and contact your
Janfire retailer or a service
technician
The feed auger bearing runs
sluggish
Contact your Janfire retailer or a
service technician
32580002_ EN_ver4
 Janfire 2014
40(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
7.5
The Burner Display is of
Event
Probable cause
Action
Display and indicator diodes
Overheating safety thermal
Cut the power to the burner.
Flashing
contact has tripped.
If the burner is still hot, let it cool
No activity in the burner.
Burning overheat
.
first and turn on the power again.
If the
burner is already cold, wait for
about 10-15 min and turn on the
power.
If the display does not come
on, break
the power again and wait a few
minutes and try again.
Display and indicator diodes
has gone off completely.
No activity in the burner.
Display and diodes has gone off
completely. The Diode on the
level sensor is still lighting.
If no actions from the
row above delivers resultsBroken electronics
Contact your dealer or Janfire
service technician .
The display is broken or the wiring
between the controlunit and the
display is broken.
Contact your dealer or Janfire
service technician .
The burner run normal
32580002_ EN_ver4
 Janfire 2014
41(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
7.5 Fuses
If the automatic fuse has blown the red button comes out.
The fuse is reset by pressing the red button.
6A Automatic
fuse.
6,3 A (5x20 mm) fast
(F) blow fuse protects
the ignition heating coil.
Figure 11 Fuses
32580002_ EN_ver4
 Janfire 2014
42(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
7.6 Adjusting the Capacity Sensor
The capacity sensor on the burner is pre-set. The setting may alter during transportation or after
some time (two weeks) during operation and will have to be adjusted.
1. Stop the burner. The main switch must be left on so that the burner has voltage.
2. Remove the drop tube from the burner’s inlet.
3. Check the diode with your finger. The sensor should be lit at a distance of 8-9 mm (see
figure below).
4. Use a small screwdriver to remove the protective plug. Turn the adjustable screw until
you get the correct distance (8-9 mm).
Anti-clockwise means less sensitivity, i.e. reacting at a shorter distance.
Clockwise means higher sensitivity, i.e. reacting at a longer distance.
8-9mm
Protective plug
Diode
Figure 1 Capacity sensor
Adjustable screw
NOTE The adjustable screw is very sensitive, only a few degrees are necessary. Do not screw to tight.
5. Mount the drop tube.
32580002_ EN_ver4
 Janfire 2014
43(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
7.7
Electrical Connection Plan
32580002_ EN_ver4
 Janfire 2014
44(45)
Operating Instructions Janfire Pellet boiler Integral Typ 25
Figure 12 Electrical connection plan
32580002_ EN_ver4
 Janfire 2014
45(45)