Operating Manual for Hands-Free Floor Mounted

Add to my manuals
4 Pages

advertisement

Operating Manual for Hands-Free Floor Mounted | Manualzz

HANDS-FREE FLOOR MOUNTED SINKS 1

Operating Manual for Hands-Free Floor Mounted Sinks

Models 501L, 501L-1.0 and 501L-0.5

Columbia does not recommend use with harsh chemicals.

NSF/ANSI Standard 2 - Food Equipment and NSF/ANSI 372 low-lead.

COLUMBIA SPECIFICATIONS

Parts List

(1) Sink bowl

(1) Pedestal base

(1) Set of 6 mounting nuts to attach bowl to pedestal base

(1) Double foot pedal valve (bottom mount) with 2 nuts

(1) Swivel gooseneck spout with aerator

(1) Connecting tubes for valve to spout connection

(2) Fittings, brass, 0.375” male compression and 0.375” male NPT

(1) Strainer assembly with basket

Installation Instructions

Step 1

1. Set the pedestal base upside down and remove bolts from under pedestal base bridge keeping the black shimmy in place.

2. Attach double foot pedal valve as shown in illustration A using the provided nuts keeping the black shimmy in place.

3. Do not over tighten nuts.

4. Install elbow fitting onto the double pedal valve.

Step 2

1. Install strainer assembly.

2. Attach bowl to pedestal base by slipping bolts on bowl through openings on pedestal base as shown in illustration B.

3. Tighten the 6 nuts to the threaded bolts under bowl. Do not over-tighten. There are 6 bolts that will securely hold the bowl in place.

Step 3

1. Place sink at the desired location.

2. Mark the floor where the four holes are at the pedestal base as shown in illustration C.

3. Drill holes as required for mounting hardware (Hardware not included).

Step 4

1. Install spout assembly to the sink.

2. Install elbow fitting (provided) to the spout assembly.

3. Connect one side of the supply line (provided) to the spout assembly.

4. Attach connecting tube from the spout to valve.

Step 5

1. Mount pedestal sink to the floor.

2. Connect waste line to strainer assembly.

3. Connect water supplies (hot and cold) onto the double foot pedal valve.

Step 6

1. Remove aerator from the spout assembly and flush water line by pressing each pedal for 30 seconds.

2. Check connections for leaks. Replace aerator onto the spout assembly.

HANDS-FREE FLOOR MOUNTED SINKS 2

Tools Required

Tape Measure

Adjustable Wrench

Drill Motor and Drill Bits

Pipe Wrench

Level

Safety Glasses

Screw Drivers: 1 Phillips & 1 Standard

Pencil

Socket Wrench

Illustration A

Illustration B

Illustration C

1622 Browning Irvine, CA 92606-4809 Phone: 949.474.0777 Toll Free: 800.626.2117 Fax: 949.474.1191 www.columbiasinks.com

email: info@ columbiasinks.com

©2016 Columbia Products

COLUMBIA SPECIFICATIONS HANDS-FREE FLOOR MOUNTED SINKS 3

Trouble Shooting Guide

Problem

Water drips from spout or valve stem assembly.

Possible Cause

Flat washer on the stem/plunger is worn.

Water leaks from the front of the valve.

O-Rings on the plunger are worn out.

To Diagnose

To determine if the leak source is from the hot or cold side shut cold water source off. See if water still leaks from the spout. If leak continues then repair hot side if not repair cold side.

Visually determine whether the cold or hot side is leaking.

Remedy

We recommend installing valve repair kit.

We recommend replacing threaded insert, plunger assembly & spring.

See illustrations below.

Valve Repair Instructions

Note: Valves are designed to be repaired without having to be disconnected from mount or plumbing.

1. Turn off water source. Do not remove valve from sink.

2. Remove pedal assembly using a 15/16” open end wrench or socket wrench. As shown in illustration A.

3. Using a 1” deep socket wrench remove insert assembly parts as show in illustration B.

4. Replace with new repair kit as shown on illustration C.

5. Reinstall pedal assembly and turn water source on.

Illustration A

Illustration B

Illustration C

1622 Browning Irvine, CA 92606-4809 Phone: 949.474.0777 Toll Free: 800.626.2117 Fax: 949.474.1191 www.columbiasinks.com

email: info@ columbiasinks.com

©2016 Columbia Products

501

COLUMBIA SPECIFICATIONS

Top

5.5” (140 mm)

19” (483mm)

17” (432mm)

2” (51mm)

14”

(356mm)

18”

(457mm)

2” drain hole

Front

1.25” R

6mm

9.5”

(241mm)

7”

(197mm)

Side

7.5” (191mm)

45º

16.5”

(419mm)

21”

(533mm)

Supply Line

25” (635mm)

.5 NPT

6” (152.4mm)

Hole Configurations

9.5”

(241mm)

9.5”

(241mm)

.875” (22mm) dia. key hole

6” (152mm)

9.5” (241mm)

HANDS-FREE FLOOR MOUNTED SINKS 4

1622 Browning Irvine, CA 92606-4809 Phone: 949.474.0777 Toll Free: 800.626.2117 Fax: 949.474.1191 www.columbiasinks.com

email: info@ columbiasinks.com

©2016 Columbia Products

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement