black ht Thermal power (A7:W45) 35 ÷ 238 kW Cooling power (A35;W7) 32 ÷ 201 kW High efficiency and high temperature air/water heat pump with axial fans and semihermetic reciprocating compressors 134a H2O 80° MINIBOSS CONTROL black HT High efficiency and high temperature air/water heat pump with axial fans and semihermetic reciprocating compressors Technical book black ht 134a CLASS A MULTI-PURPOSE R134a LOW NOISE MINIBOSS H2O 80° CONTROL 3 TWO CIRCUITS WATER UP TO 80° HORIZONTAL AIR DISCHARGE New series of dedicated heat pumps with semihermetic reciprocating compressors. Standard version in 12 sizes Thermal power (A7:W45) 35 ÷ 238 kW Cooling power (A35;W7) 32 ÷ 201 kW BLACK HT is a series of heat pumps in R134a, with the possibility of having water at 80°. SUPERVISION VIA WEB MANAGEMENT OF UP TO 4-6 UNITS WITH MINIBOSS STRONG POINTS >> H igh temperature of the produced water: up to 80°C >> Extended limits of operation in heat: air up to -20° >> Automatic management of DHW >> DWS always available (multi-purpose) >> Intelligent management of defrosts >> Subcooler and increased fin pitch >> /LN Silent version >> Supervision via web >> Management of up to 4-6 units with proprietary control >> Dual refrigerant circuit starting from size 70 The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. CONTENTS 1Technical features__________________ p.6 2 Technical data____________________ p.19 3 Electrical data_____________________ p.21 Technical book black ht 4Operating limits___________________ p.22 5 Pumps and exchanger data__________ p.23 6Cooling and heating capacity________ p.24 7Dimensional drawing_______________ p.31 5 STANDARD UNIT STRUCTURE In galvanised sheet metal and painted at 180°C with RAL7035 polyester powder, that gives high resistance against atmospheric agents. The panels can be easily removed for complete access to the internal components. All structures are equipped with two condensation collection trays with relative drain (one for each coil). COMPRESSOR Technical book Black ht 1 TECHNICAL FEATURES Semi-hermetic reciprocating compressor, complete with thermal protection included in the windings of the electric motor, crankcase heater and rubber vibration damper supports. The compressors used in this series are specifically designed to work in heat pump at very high temperatures. The optimisation of the high value compression ratio allows higher efficiencies if compared with traditional scroll compressors. The compressor is cooled by a system inside the unit. This cooling system allows an outlet water temperature of 80°C. INTERNAL EXCHANGER (SYSTEM SIDE) Brazed plates made of AISI 316 stainless steel, insulated with closed cell foam cladding that reduces heat loss and prevents the formation of condensation. The exchanger is equipped with a temperature probe for ice protection, a probe for detecting the inlet and outlet water temperature and a pallet flow switch supplied as standard. EXTERNAL EXCHANGER (SOURCE SIDE) 6 Consists of two coils with copper pipes and high exchange surface aluminium finning with fin pitch dimensioned to maximise heat exchange and reduce noise. The fin clearance of the exchanger was increased to allow the unit to work at very low outdoor temperatures and at high concentrations of humidity. At the base of the exchanger is the subcooler, a further refrigerant circuit that prevents the formation of ice in the lower part of the coil and facilitates the flow of condensation during defrosts. The effects of the subcooler are: the reduction of number of defrosts and the certainty of having a clean exchanger at the end of defrost. FANS Helicoidal fan directly coupled with electric motor, made of plastic with the blade profile with WINGLET, a special mould in the end part of the blades that allows noise reduction and an increase in ventilation performances. The control manages the fan speed through a phase-cut speed regulator, in order to optimise the operating conditions, efficiency, and allow the unit to work in heat pump, even with high outdoor temperatures. This adjustment also reduces the level of noise of the unit, in fact, the typical conditions in which the control will modulate the fan speed are the night-time and spring and autumn. This ensures that, whenever there is the opportunity, the machine decreases the fan speed to minimum and, therefore, noise. The fans are helicoidal type, directly coupled with 6-pole electric motor, with IP 54 protection degree, with shaped nozzles and accident prevention grille according to UNI EN 294. REFRIGERANT CIRCUIT Includes: >> inlet valve in the liquid and suction line >> liquid and humidity warning light >> solenoid valve >> 4-way reverse valve >> check valve >> drier filter >> electronic expansion valve >> high pressure transducer >> low pressure transducer >> high and low pressure switches >> safety valve >> liquid receiver >> suction separator >> subcooler The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. ELECTRIC PANEL The electric panel consists of: >> main cut-out switch >> Main circuit breaker and fuses to protect the auxiliary and power circuits >> compressor contactor >> fan revolution regulator for condensation and evaporation control >> contactor and pump overload cut-out (version 1P, 2P and 1R) >> general alarm dry contacts >> microprocessor controller The standard power supply is 400V/3~/50Hz for all sizes. CONTROL Microprocessor control for managing the following functions: >> Water temperature adjustment with inlet control >> Ice protection >> Compressor timing >> High pressure pre-alarm management >> Compressor high flow temperature alarm management >> Alarm signal >> Alarm reset >> Digital input for external ON-OFF >> Digital input for summer/winter selection The control allows display of the following information: >> Outlet water temperature >> Inlet water temperature >> Condensation pressure >> Evaporation pressure >> Outdoor air temperature >> Set differential and temperature set >> Description of alarms >> Pump and compressor operation counter >> Alarm history Some functions are only available with the unit properly configured. Some functions must be enabled from the control. CONTROLS AND SAFETY DEVICES >> Utility water temperature control probe (located at exchanger inlet) >> Antifreeze probe that activates the antifreeze alarm (manual reset) >> High pressure switch (automatic reset with limited interventions) >> Low pressure switch (automatic reset with limited interventions) >> Standard supplied mechanical pallet flow switch (manual reset) >> Condensation pressure control via speed regulator for operation with low outdoor temperatures >> Evaporation pressure control via speed regulator for operation with high outdoor temperatures in DHW production or recovery >> High pressure safety valve >> Compressor over-temperature protection Technical book black ht TESTING The units are tested in both summer and winter operation at the factory and are despatched filled with oil and coolant. STANDARD EQUIPMENT >> Sliding defrost management >> Compressor stop for outdoor air temperature below the operating limits >> Main disconnecting device >> Power and auxiliary circuit protection >> Microprocessor control >> Counter for compressors and pumps >> Alarm History >> Condensation and evaporation control with fan revolution regulator >> Flow switch (supplied) >> Directive 97/23/EEC (PED) Certification >> Remote On/Off from standard digital input >> Summer/Winter from standard digital input The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. 1 TECHNICAL FEATURES 7 OPTIONS CONSTRUCTIVE CONFIGURATIONS /LN Version silenced unit The unit, in addition to the basic version components, includes the compressor compartment acoustically insulated with sound-absorbing and soundproof material. The choice of coupling of the materials has allowed the removal of the frequencies generated by compressors and pumps. /OD Version unit with horizontal discharge (available up to size 75) Technical book Black ht 1 TECHNICAL FEATURES The unit in this version has horizontal air discharge. This version allows reduction of the unit height or installation where vertical discharge is not admitted for logistical reasons or noise. If equipped with EC fan high pressure, it is possible to convey the air flow for discharge through ducts. /DWS Version multi-purpose heat pump In this set-up, the unit is equipped with two utility exchangers: one on the system side for air conditioning and heating, and one exclusively for the production of DHW. A C S C H O O L T D On the system side exchanger, the unit is able to produce hot or cold water to meet, depending on the seasons, the heating and cooling requirements of the building. In the sanitary exchanger, the unit produces high temperature water to be sent to the storage tank outside the machine, selected and dimensioned according to the system requirements. Depending on the season, the unit works with different modes: the passage through various modes of operation (within the season) is automatic through the reading of the temperature probes and of the set-points set. Switching logics and times are designed to ensure maximum system efficiency and reliability. It is compulsory to associate this configuration to a suitably sized boiler in which to store high temperature water; we recommend a volume of at least 20÷25 l per thermal kW of the unit. The boiler must be provided with sump for the insertion of the DHW operating probe, located in the top part, through which the unit controller monitors the need to produce DHW. 8 The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. SUMMER OPERATION There are three summer modes of operation: >> Chiller mode: the unit only produces chilled water for the system. >> Chiller mode with simultaneous production of DHW: the unit produces chilled water for the system and DHW, simultaneously. The recovered power for the production of DHW is total. >> Heat pump mode for the production of DHW: without cold load and on call of the DHW operating probe, the unit heats the water inside the DHW storage tank, using the finned tube bundle coil as evaporator. The use of the external hot air as a source of heat ensures extremely high COP. Switching from one mode to another is entirely automatic based on a logic of priority in the production of DHW and, when there is contemporaneity of loads, recovering condensation energy for the production of DHW. WINTER OPERATION There are two winter modes of operation: >> Heat pump mode for heating: the unit produces hot water to system side exchanger for heating >> Heat pump mode for the production of DHW: produces high temperature hot water to the connected exchanger of the DHW storage. Switching from one mode to another is entirely automatic based on a logic of priority in the production of DHW. In addition to the basic version components, the /DWS version includes: >> dedicated exchanger for the production of DHW >> recovery exchanger inlet and outlet probes >> temperature probe to be placed on the DHW storage tank. HYDRAULIC MODULE OPTIONS /1P unit with pump The unit includes a circulation pump on the unit. The pump is centrifugal type, with body and impeller in AISI 304 steel. The mechanical seal is designed to work with up to 40% concentration of ethylene glycol. The electric motor is three-phase with IP 55 degree of protection. The pump is complete with thermoformed insulating shell. The different models available differ for useful head to system. /2P unit with two pumps, one in reserve to the other The unit includes two circulation pumps on the unit, one in reserve to the other, managed in rotation on an hourly basis and with automatic switching in case of failure. The pump is of centrifugal type, with body and impeller in AISI 304 steel. The mechanical seal is designed to work with up to 40% concentration of ethylene glycol. The electric motor is three-phase with IP 55 degree of protection. The pump is complete with thermoformed insulating shell. The different models available differ for useful head to system. /1R unit with DHW side pump The unit is equipped with a DHW side pump installed inside the unit. The pump is centrifugal type, with body and impeller in AISI 304 steel. The mechanical seal is designed to work with up to 40% concentration of ethylene glycol. The electric motor is three-phase with IP 55 degree of protection. The pump is complete with thermoformed insulating shell. This module can be combined only with the /DWS version units and can be combined with modules /1P or /2P. The /DWS version units without the /1R module are equipped with a consent for the management of an external pump. The different models available differ for useful head to system. /S unit with inertial tank The unit is equipped with a inertial tank (only avaible for utility and not for recovery side), installed inside the unit. The tank is sized to improve the unit’s efficiency and positioned on the system’s input. It is complete with closed cell heat insulation to decrease heat losses. It is compulsory to combine it with version /1P or /2P. The different models available differ in capacity. The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. Technical book black ht 1 TECHNICAL FEATURES 9 ACCESSORIES All units can be configured with various accessories to better meet the requirements of the specific application in which they will be inserted. To verify availability and compatibility of the accessories with size and configuration, refer to the price list or selection software. HYDRAULIC CIRCUIT ACCESSORIES >> Filling unit with pressure gauge supplied >> Antifreeze heater -- basic version: electric heater on utility exchanger -- /1P, /2P and /1R version: electric heater on utility exchanger and heating cable on piping >> 3-way valve for DHW management (supplied) >> System pump with Pulse function >> Water filter for system >> Water filter for DWS version ELECTRIC ACCESSORIES Technical book Black ht 1 TECHNICAL FEATURES >> Maximum and minimum voltage relay >> Double set-point from digital input >> RS485 Serial interface >> Remote user terminal >> Electronic soft starter >> EC Electronic fans >> EC Electronic fans high pressure (up to size 75) >> Compensation of set-point based on the outdoor air temperature >> DHW Automatic management >> DHW operating probe (standard on /DWS unit) >> Anti-legionella function >> Auxiliary heat source management >> DHW production with timer >> Single operation dry contacts >> Management relay for external pump >> Miniboss S >> Miniboss M >> Supervision via WEB VARIOUS ACCESSORIES 10 >> Rubber vibration dampers >> Packaging in wooden crate MAIN DESCRIPTION FUNCTIONALITY/ACCESSORIES Remote ON/OFF from digital input (standard) Remote ON/OFF from digital input (standard). This function is standard on all units and consists of a remote contact for the switching on and off of the machine via a signal that can be brought inside the building or controlled by a BMS (Building Management System) system. Summer/winter selection from digital input (standard) This function is standard on all heat pumps. When turning on the unit, it is always necessary to set a mode of operation that can either be heat pump or chiller. Through this remote contact it is possible to change this mode of operation also from inside the building and without the need to directly access the microprocessor control. Sliding defrosting (standard) The control manages the defrost according to a variable intervention threshold, based on the pressures inside the unit and the outdoor air temperature. By crossreferencing this information, the control is able to identify the presence of ice on the coil, activating the defrosting sequence only when necessary, so as to maximise the energy efficiency of the unit. The dynamic management of the defrost threshold ensures that for outdoor air temperatures below -5°C, when the absolute humidity of the air is very low, defrosting is only carried out when the ice on the coil degrades its performance. Auxiliary heat source management (accessory) The controller is able to manage an external heat source which, depending on the type of hydraulic connection, can be integration or back-up. The auxiliary heat source is activated when the outdoor air temperature falls below a threshold settable from control and when only the heat pump proves to be insufficient to meet the load. Activation is through the closure of a dry contact. It is also possible to set the unit so that the controller turns off the compressors when the unit works in heat pump mode and the outdoor air temperature falls below an established minimum temperature: the controller stops the compressors before the unit goes into low pressure alarm, thus avoiding having to manually reactivate the machine. This function is particularly useful when the heat pump is installed in an area where the outdoor air temperature definitely falls below the minimum temperature admitted by the operating limits (in agreement with the set-point set). When the outdoor air temperature returns above the set threshold temperature, the unit automatically starts working again without the need for any intervention. For units equipped with integrated pump, this will always be kept running in order to avoid the formation of ice and guarantee, at any moment, the correct reading of the antifreeze safety and temperature probes. The stop temperature must be set according to the highest setpoint temperature and in agreement with that admitted by the operating limits of the machine. A stop temperature The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. can be set different to the default one, as long as it is compatible with the unit’s operating limits. The standard programming provides the set-point in heating set at 40/45° with a stop temperature of -20°C Should the unit be used also for the production of DHW, the stop temperature must consider the highest water set, and the operating limits allowed. DHW Automatic management (accessory) The accessory is not compatible with accessory tank (1PS e 2PS). This feature allows the unit, through a DHW operation probe (accessory), to control the temperature inside the DHW storage tank and manage a 3-way valve (accessory) outside the unit. The priority is always for the production of DHW. Activation of the function must be requested when ordering, but it can also be configured subsequently (by qualified and authorised technical personnel), as long as the unit is connected to an appropriate hydraulic circuit. The request when ordering accessories for managing the DHW automatically involves enabling the “DHW automatic management” function. The heat pump normally operates on the system to meet the building’s comfort needs, but when the temperature of the water inside the tank drops below an established threshold, the control manages the DHW production: if the unit is operating as heat pump for heating, the 3-way valve will be switched and the set-point modified; whereas, if the unit is producing chilled water for air conditioning, the control switches the unit to heat pump mode, assigns it the set-point for DHW (normally higher than the system setpoint) and turns the 3-way valve to the appropriate position. Once the temperature inside the DHW tank has reached the set value, the unit automatically goes back to producing water for the heating and air conditioning system. Description of winter operation The following situations occur during the winter season: >> Heating request: the temperature of the inlet water to the unit, coming from the system, is lower than expected, so the control turns on the compressor and the unit will operate until the set-point temperature is reached. Once the wanted temperature is reached, the compressor stops and only the circulation pump remains in operation, continuing to circulate water in the system. The unit waits in this condition until the inlet water temperature drops again. DHW request: suppose that the unit is working for the production of hot water for the heating system (45°C) and it receives a call from the DHW operating probe located inside the storage tank to produce high temperature water, since the DHW temperature has dropped As the set limit (e.g. 55°C). Being the DHW is managed with the logic of priority, the control will change the set-point to 55°C and will switch the 3-way valve. A C S C H O O L T D As soon as the water inside the tank reaches the requested 55°C, the control will again switch the 3-way valve to operate on the system and will bring the set-point back to 45°C. Should it be necessary to defrost, in any mode the unit is operating, it will force the 3-way valve to be switched to system which, given the greater inertia, is less sensitive to the lowering of the temperature. Description of summer operation The following situations occur during the summer season: >> Cooling only: the temperature of the inlet water to the unit, coming from the system, is higher than expected, the control turns on the compressor and the unit will operate until the set-point temperature is reached. Technical book black ht 1 TECHNICAL FEATURES A C S 11 C H O O L T D A C S C H O O L T D The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. At that point, the compressor stops and only the circulation pump remains in operation, continuing to circulate water in the system. The unit waits in this condition until the inlet water temperature rises again. >> DHW request: suppose that the unit is working for the production of chilled water for the air conditioning system (7°C) and it receives a call from the DHW operating probe located inside the storage tank to produce high temperature water, since the DHW temperature has dropped below the set limit (e.g. 55°C). As the DHW is managed with the logic of priority, the control will change the unit mode from chiller to heat pump, set the set-point at 55°C and switch the 3-way valve. A C S C H O O L T D Technical book Black ht As soon as the water inside the tank reaches the requested 55°C, the control will again switch the unit to chiller mode, will turn the 3-way valve to operate on the system and will bring the set-point back to 7°C. TECHNICAL FEATURES Depending on the type of tank chosen for the production of DHW, the management of anti-legionella cycles may be necessary. The controller is able to manage them by activating, according to scheduled timing with a weekly timer, an auxiliary heat source that will perform the thermal shock on the DHW tank. The anti-legionella function is realised exclusively through an external source (e.g. electric heater). System pump with Pulse function (accessory) As standard, the unit is set to maintain the system side circulation pump always on, even when the set temperature is reached. Whereas, when the unit is equipped with this accessory, when the set-point is reached, the controller turns off the pump, reactivating it periodically, long enough to detect the water temperature. If the controller verifies that the water temperature is still in set-point conditions, it will turn off the pump again. Otherwise, the controller re-activates the compressors to meet the system requirements. This accessory allows to drastically reduce the electric absorptions due to pumping, especially during spring and autumn, when the load is extremely low. The application of this accessory requires the compulsory presence of the “Antifreeze heaters” accessory. DHW production with timer (accessory) DHW operating probe (accessory) 1 Anti-legionella function (accessory) For the production of DHW, the controller requires this accessory: it is a temperature probe with 6 m cable located in an appropriate sump of the tank for the production of DHW. For proper positioning, read the “Advice for installing a heat pump” section. Standard on units in DWS version. With this accessory present, it will be possible to associate two different temperatures for the DHW to different times of the day: Normal and Saving. This allows you to decide at what time of the day the heat pump must concentrate the production of DHW, always keeping the minimum level of Saving temperature, and always managed with the logic of priority. For example, by concentrating the production of water at Normal temperature during night-time, the best electricity rates will be exploited and production of DHW will be ensured before the time of greater consumption. 12 With this system, the unit never stops controlling the temperature inside the DHW tank and if hot water is occasionally used outside the regular times, the unit will give the production of DHW priority until it brings the water in the tank to a temperature equal to the Saving set-point. The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. Electronic thermostatic valve (standard) MINIBOSS S (accessory) Using this accessory is particularly suitable on units having to operate in very variable heat load conditions, with strong differences of outdoor air temperature or with frequent change of operating mode, like in joint management of air conditioning, heating and production of high temperature water. The use of the electronic thermostatic valve allows: >> maximisation of the heat exchange to the utility exchanger >> minimisation of the response times of the refrigerant circuit to the variations of the operating conditions and load >> optimisation of the superheat adjustment >> maximisation of energy efficiency The Miniboss S allows connection of up to 6 units in parallel: management allows activation and deactivation of them at power steps and makes them rotate, thus allowing an identical use of all units. The connected units must all be the same. The Miniboss S cannot control units with the DHW management active. Directly from the Miniboss S panel it is possible to manage: >> the system set-point >> the summer/winter selection of all machines >> the ON/OFF of the single units or of the entire system This accessory is supplied in an electrical panel with the unit (to be installed in a technical compartment); it must be provided on only one machine connected in parallel and all connected units must have the same configuration. When ordering, it is compulsory to specify the number of units that must be managed to allow for proper programming of the supervisor. Furthermore, the hydraulic circuit connecting the units must compulsorily respect one of the following diagrams. For more information on the use, refer to the specific documentation. MINIBOSS M (accessory) The Miniboss M allows management of up to 4 units in parallel. The main functions are: >> Manage units with DWS configurations >> Manage systems with a hot/cold tank for heating/air conditioning and a hot tank for the production of DHW EC Fans (accessory) The units can be requested with EC fans, with electronic switching brushless motor. These motors with permanent magnet rotor ensure very high levels of efficiency for each working condition and allow a 15% saving on the power absorbed by each fan. Furthermore, the microprocessor, through a 0-10V analogue signal sent to each fan, controls the condensation/evaporation through continuous adjustment of the air flow rate upon variation of the outdoor air temperature, with a further decrease of electric absorptions and a reduction of sound emissions. In addition to that also carried out by the Miniboss S: >> the system set-point >> the DHW set-point >> use a compensation climate of the system set-point >> the summer/winter selection of all machines >> the ON/OFF of the single units or of the entire system >> the switching of three-way valves >> manage the operation of pumps outside the units This accessory is supplied in an electrical panel with the unit (to be installed in a technical compartment), it must be provided on only one machine connected in parallel and all connected units must have the same configuration. When ordering, it is compulsory to specify the number of units that must be managed to allow for proper programming of the supervisor. For more information on the use, refer to the specific documentation. Filling unit with pressure gauge (accessory) This accessory allows automatic loading of the hydraulic system, adjustment of the correct working pressure, always verifiable through the pressure gauge, and continuously maintains this pressure by reintegrating the missing water. The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. Technical book black ht 1 TECHNICAL FEATURES 13 Antifreeze heater (accessory) Remote user terminal (accessory) This accessory consists in heaters inserted on the utility exchanger, on the pump and in the tank (based on the machine configuration) to prevent damaging the hydraulic components following the formation of ice during machine downtime. The power of the antifreeze heaters is only of a few tens of watts, depending on the unit model, meaning sufficient enough to avoid failure of the components. The control monitors (even when the unit is in stand-by) the outlet pump from the exchanger and when this detects a water temperature below or equal to 5°C (or 2°C below set-point temperature, with differential of 1°C), it turns on the pump (if present) and makes the antifreeze heaters intervene. If the outlet water temperature reaches 4°C (or 3°C below set-point), the antifreeze alarm will also trigger, stopping the compressor, keeping the heaters active. The antifreeze heaters are present in the evaporator and on any recovery exchangers. This accessory consists in a copy of the remote control panel, from where it is possible to fully configure the unit and display all its parameters. Access to the masks is via passwords that enable the different levels of modification. Double set-point from digital input (accessory) Technical book Black ht The double set-point allows two different working temperatures to be set: one for heating operation and one for cooling operation. Should a double set-point be required for both modes, it will be compulsory to provide the electronic thermostatic valve. The set-point temperatures must be specified when ordering. The setpoint can be changed from keyboard or from digital input. RS485 Serial interface (accessory) 1 TECHNICAL FEATURES The growing diffusion of home automation systems and BMS (Building Management System) has led to the need to integrate all plant components under a single supervision. To meet this requirement, the unit can be equipped with a RS485 serial board with MODBUS protocol. DHW 3-way valve (accessory) The accessory is not compatible with accessory tank (1PS e 2PS). It is an on/off type three-way valve that, combined with the automatic management of DHW function, allows the machine to manage two separate circuits for comfort and DHW production, automatically switching from one to the other based on the system need. The DHW 3-way valve must be installed in a technical compartment. Compensation of set-point depending on the outdoor temperature (accessory) The controller allows modification of the unit set-point both in chiller operation and in heat pump, depending on the outdoor temperature. Compensation can be positive or negative: with positive compensation, upon outdoor air temperature increase, the summer temperature set-point will also increase, while with the negative compensation, upon air temperature increase, the temperature set-point decreases. Should the unit be used also for the production of DHW, the adjustment climate will not affect the DHW temperature set-point. Maximum and minimum voltage relay (accessory) This device continuously controls the unit’s power supply voltage, ensuring it is always within an admissible range. Should the voltage value be above or below that range, the device stops the unit to avoid damaging the electric motors. The same device also controls the phase sequence. 14 The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. Condensation/evaporation control with revolution regulator (standard) The microprocessor control of the unit controls all operating parameters of the unit and continuously adjusts the speed of the fans through a revolution regulator, in order to optimise the operating conditions and the efficiency of the unit. This adjustment also reduces the level of noise of the unit, in fact, the typical conditions in which the control will modulate the fan speed are the night-time and spring and autumn. This ensures that, whenever there is the opportunity, the machine decreases the fan speed to minimum and, therefore, noise. Water filter (accessory) The water filter, located at the unit’s water inlet, aims at preventing sludge, processing residues or other, from clogging the unit exchangers. It is compulsory that at the inlet of each circuit: source, utility and recovery, there is a filter with a 0.4 or 0.5 mm mesh. The absence of the filter automatically voids the warranty. Condensing drain pan (standard) This accessory is compulsory when installed in a passageway. This is a drain pan used during winter mode (heat pump functions) to contain the water coming from the coil (also during defrost operating). This is standard on all products. Web supervision (accessory) The units can be remotely managed in 2 different ways: >> via web through LAN >> via web through modem and telephone board (integrated in supervision) The unit can be controlled totally through the connection. The display possibilities are: >> Inlet water temperature >> Outlet water temperature >> Air temperature >> Condensation pressure >> Evaporation pressure >> Status of the unit >> Presence of alarms >> Compressor operation >> Pump operation >> Fan operation percentage The modification possibilities are: >> Power on and off of the unit >> Switching of status: summer/winter or vice-versa >> Reset of alarms. All unit alarms can be reset without physically reaching the installation >> Modification of all set-points >> Modification of climates It is also possible to view a history of the operation of all variables (temperatures and pressures) detected by the control. This allows a view of the effective behaviour of the unit and of the system. This function is essential to correctly set the system. Relay for outdoor pump management If the unit is purchased without pumps, the customer is entrusted with the start and stop of the pump in accordance with the instructions in the installation, operation and maintenance manual. This accessory is necessary if the unit needs to control one or more external pumps. It allows control of an external pump with the same logic as a pump integrated in the unit. The accessory consists in the supply of a dry contact only usable for controlling the start and stop. The customer is responsible for the protection and power. The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. Technical book black ht 1 TECHNICAL FEATURES 15 RECOMMENDATIONS FOR INSTALLATION The following instructions are intended to improve use of the heat pumps in systems and to prevent installation problems. 1.Heat Pumps are often combined with radiant heating systems. If the radiant system is in areas with control of the individual manifold head, it is compulsory to provide at least 20 litres of water per kW of heat yield of the unit, in condition of minimum water content, or with all heads closed. This is necessary because it is possible that a situation arises where almost all heads are closed and the heat pump works with an extremely reduced water volume. In this case, during defrosting, it is possible that the safety devices intervene due to excessive cooling of the water. 2.In the DWS version or with use of the “DHW automatic management” function, it is compulsory to work the recovery exchanger on technical water and not on pipe coil. In fact, the coupling of heat pumps with pipe coils has repeatedly proven to be a problem due to an incorrect dimensioning of the pipe coil surface. Technical book Black ht 1 TECHNICAL FEATURES 16 3.In the DWS version or with use of the “DHW automatic management” function, installation of the temperature probe supplied is essential. The DHW storage tank must have a sump in its top part, long enough to reach almost the centre of the tank. The probe supplied with the unit must be inserted in the sump with conductive paste in order to allow the probe to accurately read the tank temperature. The incorrect reading of the temperature, caused by an unsuitable positioning, may lead to the intervention of the safety devices or blocking of the unit. 4. When using the “DHW automatic management” logic, it is necessary to use a three-way valve which, during switching, allows the water to flow and never presents the situation of blocked or reduced flow. The Installation, Operation and Maintenance Manual contains guidelines for selecting the valve. 5.The possible integration of water from the aqueduct must never be inserted in the inlet piping of the heat pump. The cold water made to abruptly enter the “hot” exchanger may cause the safety devices to intervene. If using a tank, the inlet of the water integration from the aqueduct must not directly flow in the inlet piping of the heat pump. 6.For the following reasons, it is not advisable to position the unit set-points on the operating limits: a.Modification of the room temperature. The room temperature varies and may lead the unit to work outside the limits. b.Presence of the water filter. The water filter must always be present at the unit’s water inlet, under penalty of voiding the warranty. The filter will certainly get dirty over time. A dirty filter will increase load losses and consequently the flow rate. The DT increases and can go from 4/5° to 9°, 10°, causing the safety devices to intervene. c.If the hydraulic circuit provides more areas, it may happen that when a circuit closes the pump has to operate on the remaining hydraulic circuit. This increases the load losses, decreases the flow rate and increases the DT with possible intervention of the safety devices. d.In summer, the unit will be subject to solar radiation. Assuming air at 35°, the coil (in copper and aluminium, so very good conductor) will be at a very high temperature. When turning on the unit, even with fans at stand-still, the evaporation will be very high thus certainly producing the intervention of the high pressure switch. e.Recirculation of air can create a micro-environment with a lower temperature of even 4/5°, leading the unit to operate outside the limits. f.Clearances are very important, the upstream or downstream obstruction of the fan causes load losses that reduce the air flow rate. This reduction may cause the operating temperatures to drop. This drop may cause the unit to be outside the operating limits. g.Air in the circuit. The air in the system, even if wellvented, creates a heat exchange coefficient loss with possible consequential intervention of the high pressure safety devices. The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. 7.Use of unit to dry the screed. When building a house large amounts of water are used for the mortar, plaster, screed, which then evaporate from the building very slowly. Also, rain may significantly increase the humidity content of the construction. Due to the high humidity content in the whole building, during the first two heating periods, the heat requirement of the building is much higher. The masonry work must be dried using special equipment. If the heat power of the heat pump was calculated to be sufficient for the home and drying takes place in the autumn or winter, we recommend installing an additional electric heater to compensate the higher heat requirement. 8.Starting the system with low outdoor temperatures. The safety devices may intervene when starting the system during winter, with the temperature of the system water particularly cold and outside the unit’s operating limits. To bring the system up to speed, just reduce the heat load by isolating part of the system. When the temperature of the partial system water is within the operating limits, it will be possible to also connect the previously isolated part of the system. 9.During defrosting, the unit cools the system water in order to eliminate the ice in the coil. To eliminate any problem, it is appropriate to insert a storage of at least 20÷25 litres of water per thermal kW of the unit. ACOUSTIC ASPECTS FOR THE INSTALLATION For proper unit installation, keep the following in mind: >> Installation of the unit near walls or other creates reverberation phenomena that increase the input of noise in the environment, even by 16 dBA >> Bear in mind the possible sensitive receptors when installing the unit; avoid installing units near bedrooms >> Check the noise regulation of the municipality where the unit will be installed to verify its absolute and differential limit >> Bear in mind that, regardless of the acoustic class of the territory (Italian Prime Ministerial Decree 14 November 1997), there is a differential day and night-time criterion >> In the event of critical installations, contact a Competent Technician in Acoustics for a preliminary evaluation Italian Prime Ministerial Decree 14 November 1997 The Italian Prime Ministerial Decree 14/11/97, which entered into force on 1st January 1998, determines the limit values of the sound sources, in particular it sets: >> Emission limit values maximum noise that can be emitted by a source; >> Input limit values maximum noise that can be input by one or more sound sources in the house or in the external environment, divided into absolute and differential; >> Attention values of noise that signal the presence of a potential risk to health or for the environment; >> Quality values of noise to achieve as a target in the short-, medium- and long-term. The Italian Prime Ministerial Decree 14/11/97, like the Italian Prime Ministerial Decree 1/3/91, sets the absolute input limits for the outdoor environment for all types of sources. The decree also defines the limit values of emissions to be understood as “emission levels for a specific source evaluated at the receiver”. These values, with the exception of the transport infrastructures, must be complied with by all sound sources. The limit values are set by acoustically dividing the territory in six classes. In particular, it is very important to know the “differential criterion” present and described in the decree. It is this criterion that most technicians do not know and which is the most restrictive. DIFFERENTIAL CRITERION The differential noise level is the difference between the ambient noise level (i.e. that present when the noise source causing the disturbance is in operation) and the residual noise level (i.e. background noise). The differential noise level must not exceed the following input differential limit values (art. 4, comma 1 of Italian Prime Ministerial Decree 14/11/97): >> 5 dB(A) for the daytime period (from 6.00-to 22.00) >> 3 dB(A) for the night-time period (from 22.00-to 6.00) The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. Technical book black ht 1 TECHNICAL FEATURES 17 ETHYLENE GLYCOL CORRECTIVE COEFFICIENTS Correction factors for the presence of Ethylene Glycol 5% 10% 15% 20% 25% 30% 35% 40% Freezing temperature ETHYLENE GLYCOL % IN WEIGHT °C -2,0 -3,9 -6,5 -8,9 -11,8 -15,6 -19 -23,4 Safety temperature °C 3,0 1,0 -1,0 -4,0 -6,0 -10,0 -14,0 -19,0 Cooling Power Coefficient - 0,995 0,990 0,985 0,981 0,977 0,974 0,971 0,968 Absorbed Power Coefficient - 0,997 0,993 0,990 0,988 0,986 0,984 0,982 0,981 Mass flow rate coefficient - 1,003 1,010 1,020 1,033 1,050 1,072 1,095 1,124 Load losses coefficient - 1,029 1,060 1,090 1,118 1,149 1,182 1,211 1,243 The maximum admitted percentage of glycol per standard unit is 40%. For higher values, contact the sales department. PERFORMANCE ACCORDING TO EN14511 STANDARD Data is provided according to the requirements of EN14511. This set of rules redefines the method for calculating the performances of the heat pump chillers. According to EN14511-2011, on the unit performance calculation, also add the power required to overcome the hydronic load losses of the circuit. Method of calculation of the performance as follows. P cooling= P cooling - P abs.Δp Technical book EN14511 Black ht P heating= P heating + P abs.Δp EN14511 1 TECHNICAL FEATURES P abs = P abs + P abs.Δp EN14511 P cooling EN14511 EER EN14511 = ————— P abs EN14511 P heating EN14511 18 COP EN14511 = ————— P abs EN14511 ESEER EN14511 = 0.003 x EER 100% + 0.33 x EER 75% + 0.41 x EER 50% + 0.23 x EER 25% EN14511 EN14511 EN14511 EN14511 With: Pcooling : cooling power Pheating : heating power Pcooling , Pheating , EEREN14511, COPEN14511, ESEEREN14511 : data provided in compliance with EN14511 EN14511 EN14511 Pabs : electric power absorbed (compressors and fan section) [ kW ] Pabs.Δp : electric power absorbed by the pump to overcome load losses of water in the heat exchanger The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. TECHNICAL DATA UNIT SIZE Heating (EN 14511 values) Nominal heating capacity Total Power input in heating mode COP Efficiency class SCOP Seasonal Efficiency class Heating (EN 14511 values) Nominal heating capacity Total Power input in heating mode COP Cooling (EN 14511 values) Nominal cooling capacity Total Power input in cooling mode EER ESEER Efficiency class Compressor Type Quantity/Refrigerant circuits Capacity steps Total oil charge Total refrigerant charge Fans Type - axial Quantity Air flow Utility side exchanger Type Water content Water flow rate (A35/W7) Pressure drop (A35/W7) Water flow rate (A7/W75) Pressure drop (A7/W75) Water flow rate (A7/W45) Pressure drop (A7/W45) Hydraulic module Available pump pressure Nominal Power input of pump Available pump pressure (A35/W7) Available pump pressure (A7/W45) Storage tank capacity Expansion vessel Hydraulic connection Connection Sound level STD version Sound power value Sound pressure value Sound level LN version Sound power value Sound pressure value Basic unit size and weights (1), (7) kW (1), (2), (7) kW (1), (7) (9) (9) (8) kW (2), (8) kW (8) (3), (7) kW (3), (2), (7) kW (3), (7) n° / n° n° kg kg 40 45 55 65 75 90 33,6 10,7 3,22 A 3,42 A+ 40,3 12,6 3,30 A 3,45 A+ 51,0 15,3 3,41 A 3,58 A+ 59,2 16,3 3,44 A 4,02 A++ 71,7 22,0 3,08 B 3,62 A+ 84,9 25,3 3,13 B 3,75 A+ 25,3 12,5 2,03 30,5 14,3 2,13 36,4 16,7 2,18 45,8 19,8 2,32 54,6 25,9 2,11 63,1 29,4 2,15 32,0 10,7 2,98 3,52 B 36,8 13,5 2,72 3,14 C 46,8 17,0 2,76 3,11 C 56,3 18,8 3,00 3,37 B 62,5 22,6 2,76 3,26 C 74,3 27,1 2,74 3,26 C 1/1 2 4,0 11,3 1/1 2 4,5 13,5 Reciprocating 1/1 1/1 2 2 4,8 4,8 17,1 19,8 1/1 2 4,8 24,1 1/1 2 4,8 28,5 1 21.000 1 21.000 1 20.000 1 20.000 2 40.000 2 40.000 2,3 5.524 17 4.239 9 5.840 19 2,7 6.353 18 5.245 10 6.954 21 Plate exchanger 3,4 4,0 8.083 9.715 18 21 5.721 6.932 8 10 8.803 10.212 21 24 4,8 10.794 23 8.409 11 12.456 31 5,7 12.822 16 9.527 7 14.682 21 P1 1,1 184 181 - P1 1,1 181 176 - P1 1,1 177 171 - P1 1,1 168 164 - P2 2,5 192 182 200 18 P2 2,5 196 186 200 18 1" 1/2 1" 1/2 1" 1/2 1" 1/2 2" 2" 83 55 83 55 84 56 85 57 86 58 86 58 Axial n° m3/h l (3) l/h (3) kPa (8) l/h (8) kPa (1) l/h (1) kPa kW (3) kPa (1) kPa l l (4), (6) dB(A) (5), (6) dB(A) (4), (6) dB(A) (5), (6) dB(A) 81 53 81 53 82 54 83 55 84 56 84 56 Width mm 1.408 1.408 1.408 1.408 3.508 3.508 Depth mm 1.208 1.208 1.208 1.208 1.208 1.208 Height mm 2.390 2.390 2.390 2.390 1.912 1.912 Delivery weight kg 585 592 630 648 1.017 1.142 Operating weight kg 590 597 637 656 1.027 1.152 (1) External air temperature 7°C BS, 6°C BU, Inlet-outlet water 40-45 °C (2) Total power input is sum of compressors and funs power input and pump, according with EN 14511 (3) External air temperature 35°C, Inlet-outlet water 12-7°C . (4) Sound power level calculate in compliance with ISO 3744 (5) Sound pressure level calculate in compliance with ISO 3744 (6) External air temperature 35°C, Inlet-outlet water 12-7°C . (7) Values calculate in compliance with EN 14511 (8) External air temperature 7°C BS, 6°C BU, Inlet-outlet water 70-75 °C (9) according to European Regulation n° 813/2013 This datasheet gives the characteristic data of the basic and standard versions of the series; for details refer to the specific documentation The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. Technical book black ht 2 TECHNICAL DATA 19 TECHNICAL DATA UNIT SIZE Technical book Black ht 2 TECHNICAL DATA 20 Heating (EN 14511 values) Nominal heating capacity Total Power input in heating mode COP Efficiency class SCOP Seasonal Efficiency class Heating (EN 14511 values) Nominal heating capacity Total Power input in heating mode COP Cooling (EN 14511 values) Nominal cooling capacity Total Power input in cooling mode EER ESEER Efficiency class Compressor Type Quantity/Refrigerant circuits Capacity steps Total oil charge Total refrigerant charge Fans Type - axial Quantity Air flow Utility side exchanger Type Water content Water flow rate (A35/W7) Pressure drop (A35/W7) Water flow rate (A7/W75) Pressure drop (A7/W75) Water flow rate (A7/W45) Pressure drop (A7/W45) Hydraulic module Available pump pressure Nominal Power input of pump Available pump pressure (A35/W7) Available pump pressure (A7/W45) Storage tank capacity Expansion vessel Hydraulic connection Connection Sound level Sound power value Sound pressure value Sound level Sound power value Sound pressure value Basic unit size and weights (1), (7) kW (1), (2), (7) kW (1), (7) (9) (9) (8) kW (2), (8) kW (8) (3), (7) kW (3), (2), (7) kW (3), (7) n° / n° n° kg kg n° m3/h l (3) l/h (3) kPa (8) l/h (8) kPa (1) l/h (1) kPa kW (3) kPa (1) kPa l l 70 85 105 125 145 180 200 235 68,8 21,0 3,33 A 3,50 A+ 81,5 25,7 3,24 A 3,40 A+ 103,8 32,0 3,29 A 3,48 A+ 120,1 32,9 3,31 A 4,00 A++ 143,0 42,3 3,14 B 3,74 A+ 171,2 50,6 3,24 A 3,78 A+ 202,3 61,9 3,29 A 3,63 A+ 234,4 71,4 3,31 A 3,63 A+ 51,8 24,4 2,12 61,0 29,1 2,09 74,2 35,1 2,11 93,0 40,1 2,32 110,1 50,7 2,17 128,2 59,5 2,15 150,6 70,8 2,13 182,6 86,7 2,11 61,4 21,4 2,87 3,22 C 71,3 25,9 2,75 3,12 C 90,6 32,3 2,80 3,17 C 100,7 34,6 2,91 3,29 B 120,9 44,6 2,71 3,17 C 145,2 52,3 2,78 3,17 C 173,8 65,2 2,66 3,06 D 201,1 78,0 2,58 3,00 D 2/2 4 8,0 23,1 2/2 4 9,0 27,5 2/2 4 9,5 34,8 Reciprocating 2/2 2/2 4 4 9,5 9,5 40,4 48,3 2/2 4 9,5 56,9 2/2 4 14,8 67,2 2/2 4 10,0 77,9 2 40.000 2 40.000 2 40.000 Axial 2 3 40.000 60.000 3 60.000 4 80.000 4 80.000 4,6 10.581 13 8.478 7 11.914 16 5,5 12.291 16 10.490 9 14.187 22 7,0 15.630 15 11.443 6 17.958 20 Plate exchanger 8,1 9,7 17.352 20.843 14 15 13.864 16.819 6 7 20.832 24.912 20 22 11,4 25.039 19 21.685 10 29.363 26 13,4 29.957 20 24.583 10 34.686 26 15,6 34.669 20 29.848 11 40.189 28 P2 2,5 202 197 200 18 P2 2,5 197 187 200 18 P2 2,5 189 176 200 18 P2 2,5 184 164 200 18 P3 3,0 190 179 400 18 P3 3,0 182 169 400 18 P3 3,0 174 159 400 18 P3 3,0 165 145 400 18 2" 1/2 2" 1/2 2" 1/2 2" 1/2 2" 1/2 2" 1/2 3" 3" 87 59 87 59 88 60 88 60 89 61 89 61 93 65 93 65 (4), (6) dB(A) (5), (6) dB(A) (4), (6) dB(A) (5), (6) dB(A) 85 57 85 57 86 58 86 58 87 59 87 59 91 63 91 63 Width mm 3.508 3.508 3.508 3.508 4.608 4.608 5.330 5.330 Depth mm 1.208 1.208 1.208 1.208 1.208 1.208 1.208 1.208 Height mm 1.912 1.912 1.912 1.912 1.912 1.912 1.912 1.912 Delivery weight kg 1.323 1.505 1.539 1.541 1.744 1.759 2.099 2.268 Operating weight kg 1.334 1.516 1.550 1.552 1.758 1.773 2.114 2.284 (1) External air temperature 7°C BS, 6°C BU, Inlet-outlet water 40-45 °C (2) Total power input is sum of compressors and funs power input and pump, according with EN 14511 (3) External air temperature 35°C, Inlet-outlet water 12-7°C . (4) Sound power level calculate in compliance with ISO 3744 (5) Sound pressure level calculate in compliance with ISO 3744 (6) External air temperature 35°C, Inlet-outlet water 12-7°C . (7) Values calculate in compliance with EN 14511 (8) External air temperature 7°C BS, 6°C BU, Inlet-outlet water 70-75 °C (9) according to European Regulation n° 813/2013 This datasheet gives the characteristic data of the basic and standard versions of the series; for details refer to the specific documentation The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. ELECTRICAL DATA UNIT SIZE 40 45 55 65 75 90 Maximum absorbed power 22,6 26,6 31,6 37,6 45,2 54,2 (23,7) (27,7) (32,7) (38,7) (47,7) (56,7) 41,1 47,9 57,1 68,3 81,7 104,0 (43,8) (50,6) (59,8) (71,0) (86,2) (108,5) Maximum starting current Full load current (1),(3) kW (2),(3) A (4) A 104,8 132,8 172,8 172,8 234,6 241,6 (62,9) (79,7) (103,7) (103,7) (140,8) (145,0) Fan motor nominal power n° x kW 1 x 1,6 1 x 1,6 1 x 1,6 1 x 1,6 2 x 1,6 2 x 1,6 Fan motor nominal absorbed current n° x A 1 x 3,9 1 x 3,9 1 x 3,9 1 x 3,9 2 x 3,9 2 x 3,9 Pump motor nominal power kW 1,10 1,10 1,10 1,10 2,45 2,45 Pump motor nominal current A 2,70 2,70 2,70 2,70 4,53 4,53 Power supply V/ph/Hz 400/3N~/50 ±5% Power supply V/ph/Hz 230/1~/50 ±5% UNIT SIZE 70 85 105 125 145 180 200 235 Maximum absorbed power 45,2 53,2 63,2 75,2 88,8 106,8 198,4 162,4 (47,7) (55,7) (65,7) (77,7) (91,8) (109,8) (201,4) (165,4) 82,2 95,8 114,2 136,6 159,5 204,1 358,0 293,6 (86,7) (100,3) (118,7) (141,1) (165,9) (210,5) (364,4) (300,0) 142,0 176,8 226,0 237,2 304,6 333,9 481,0 555,6 Maximum starting current Full load current (1),(3) kW (2),(3) A (4) A (85,2) (106,1) (135,6) (142,3) (182,8) (200,3) (288,6) (333,4) n° x kW 2 x 1,6 2 x 1,6 2 x 1,6 2 x 1,6 3 x 1,6 3 x 1,6 4 x 1,6 4 x 1,6 n° x A 2 x 3,9 2 x 3,9 2 x 3,9 2 x 3,9 3 x 3,9 3 x 3,9 4 x 3,9 4 x 3,9 Pump motor nominal power kW 2,45 2,45 2,45 2,45 3,00 3,00 3,00 3,00 Pump motor nominal current A 4,53 4,53 4,53 4,53 6,35 6,35 6,35 6,35 Fan motor nominal power Fan motor nominal absorbed current Power supply V/ph/Hz 400/3N~/50 ±5% Power supply V/ph/Hz 230/1~/50 ±5% Technical book black ht 3 ELECTRICAL DATA 21 Notes >> Voltage unbalance: max 2% >> “The standard power supply voltage (see specific wiring diagram) must not vary by more than ±5%” >> Electric data refers to standard unit. Data may change based on the installed accessories (1) Mains power supply to allow unit operation (2) Maximum current before safety cut-outs stop the unit. This value is never exceeded and must be used to size the electrical supply cables and relevant safety devices (refer to electrical wiring diagram supplied with the unit). (3) alues in brackets refer to ST version units (units with storage tank and pumps or units with exclusively pumps) (4) Maximum starting current calculated considering the bigger size compressor starting current plus the maximum absorbed power of the other electrical devices (pumps, fans) The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. OPERATION LIMITS OPERATION IN COOLING Utility water outlet temperature [°C] Raffreddamento 25 20 15 10 5 ➀ 0 -5 -10 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 External air temperature [°C] Notes >> The thermal head to the utility side exchange must be between 3°C and 6°C >> ➀ : in this area the unit can only work with evaporator side glycoled water >> Operating outside the operating limits may cause the safety devices to intervene or serious malfunctions >> Within the operating limits, the fan section may be subject to modulation Utility water outlet temperature [°C] HEATING AND RECOVERY OPERATION HT VERSION Riscaldamento e Recupero Technical book Black ht 4 OPERATION LIMITS Notes 85 75 65 55 45 35 25 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 External air temperature [°C] >> The thermal head to the utility side exchange must be between 3°C and 6°C >> Operating outside the operating limits may cause the safety devices to intervene or serious malfunctions >> The temperature of inlet water to utility side exchanger cannot be less than 25°C >> ■ The unit can work within this field but NOT CONTINUOUSLY >> Within the operating limits, the fan section may be subject to modulation >> Within the operating limits, to limit the flow temperature, the unit may be subject to choking 22 The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. PRESSURE DROP DIAGRAM 80 40 45 Pressure drop Diagram 55 65 70 85 75 105 90 Plate exchanger Pressure Drop [kPa] 70 125 145 60 180 50 200 40 235 30 20 10 0 3000 6000 9000 12000 15000 18000 21000 24000 27000 30000 33000 36000 39000 42000 45000 Flow rate [l/h] Technical book black ht 5 AVAILABLE PRESSURE DIAGRAM 220 85 210 40 200 EXCHANGER DATA 90 190 Available Pressure [kPa] 180 45 170 160 105 70 150 140 200 125 235 130 145 55 120 110 180 75 100 90 65 80 70 60 50 3000 6000 9000 12000 15000 18000 21000 24000 27000 30000 33000 36000 39000 42000 45000 Flow rate [l/h] The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. 23 COOLING CAPACITY Ta [°C] 40 25 30 35 40 45 To [°C] KWF kWe EER KWF kWe EER KWF kWe EER KWF kWe EER KWF kWe EER 10/5 33,2 9,3 3,6 32,6 10,1 3,2 30,6 10,4 2,9 28,7 10,9 2,6 27,0 11,3 2,4 11/6 35,6 9,8 3,6 33,2 10,2 3,3 31,6 10,7 3,0 29,6 11,1 2,7 27,8 11,5 2,4 12/7 35,6 9,7 3,7 35,3 10,5 3,4 32,0 10,7 3,0 31,6 11,5 2,7 28,9 11,8 2,5 13/8 36,6 9,8 3,7 35,3 10,5 3,4 33,9 11,0 3,1 31,9 11,6 2,8 28,9 11,8 2,4 14/9 38,2 10,1 3,8 36,5 10,7 3,4 34,6 11,2 3,1 32,5 11,8 2,8 30,7 12,3 2,5 15/10 38,6 10,3 3,8 37,5 10,8 3,5 36,3 11,6 3,1 33,7 12,0 2,8 31,9 12,5 2,5 17/12 41,8 10,6 3,9 39,8 11,3 3,5 38,4 12,0 3,2 35,9 12,5 2,9 33,1 12,8 2,6 19/14 44,4 11,0 4,0 42,9 11,8 3,6 40,4 12,4 3,3 38,4 12,9 3,0 34,8 13,3 2,6 21/16 45,9 11,2 4,1 45,9 12,2 3,8 43,4 12,8 3,4 40,6 13,5 3,0 37,7 13,9 2,7 23/18 49,7 11,6 4,3 47,8 12,4 3,9 47,3 13,4 3,5 44,0 14,1 3,1 - - - 10/5 39,9 12,1 3,3 37,0 12,5 3,0 34,6 13,0 2,7 32,8 13,6 2,4 30,5 13,9 2,2 11/6 40,2 12,3 3,3 37,5 12,8 2,9 35,9 13,4 2,7 33,9 13,7 2,5 31,1 14,0 2,2 12/7 41,3 12,4 3,3 40,8 13,3 3,1 36,8 13,5 2,7 34,4 14,0 2,5 32,4 14,5 2,2 13/8 43,6 12,8 3,4 40,6 13,3 3,1 38,2 13,8 2,8 36,5 14,4 2,5 33,2 14,5 2,3 14/9 44,5 12,9 3,4 42,7 13,6 3,1 41,2 14,4 2,9 37,2 14,6 2,6 34,3 14,9 2,3 15/10 46,1 13,2 3,5 43,8 13,8 3,2 41,6 14,6 2,8 38,3 14,8 2,6 36,1 15,4 2,3 17/12 49,9 13,9 3,6 45,8 14,1 3,2 43,9 14,9 3,0 40,4 15,4 2,6 37,5 15,8 2,4 19/14 51,4 14,3 3,6 48,8 14,8 3,3 46,8 15,4 3,0 43,4 15,9 2,7 39,6 16,4 2,4 Technical book 21/16 54,7 14,7 3,7 52,6 15,3 3,4 49,2 16,0 3,1 45,4 16,5 2,8 42,4 17,1 2,5 Black ht 23/18 58,0 15,2 3,8 54,9 15,8 3,5 52,2 16,5 3,2 48,6 17,3 2,8 - - - 10/5 49,0 15,4 3,2 45,4 15,8 2,9 44,1 16,6 2,7 40,6 16,8 2,4 37,1 17,0 2,2 11/6 50,4 15,6 3,2 48,1 16,1 3,0 45,7 16,9 2,7 41,6 17,0 2,4 38,3 17,4 2,2 12/7 52,1 16,0 3,3 50,1 16,5 3,0 46,8 17,0 2,8 44,1 17,5 2,5 40,1 17,9 2,2 13/8 54,0 16,3 3,3 50,8 16,7 3,0 48,5 17,4 2,8 45,4 17,9 2,5 41,1 18,1 2,3 14/9 55,5 16,6 3,4 52,6 17,0 3,1 50,2 17,8 2,8 45,8 18,0 2,5 42,0 18,3 2,3 15/10 57,7 16,9 3,4 56,1 17,8 3,2 51,1 17,8 2,9 47,6 18,4 2,6 44,1 19,0 2,3 17/12 62,6 17,6 3,6 58,2 18,0 3,2 54,2 18,4 2,9 50,6 19,1 2,6 46,9 19,6 2,4 19/14 64,8 18,0 3,6 60,5 18,4 3,3 58,1 19,3 3,0 53,9 19,9 2,7 49,5 20,3 2,4 21/16 70,0 18,7 3,7 66,2 19,4 3,4 61,1 19,9 3,1 57,2 20,6 2,8 52,6 21,1 2,5 23/18 73,4 19,3 3,8 69,1 19,8 3,5 65,1 20,7 3,1 60,0 21,2 2,8 - - - 10/5 56,1 16,2 3,5 54,2 17,0 3,2 50,7 17,7 2,9 49,4 18,5 2,7 45,2 19,2 2,4 11/6 58,5 16,7 3,5 54,9 17,4 3,2 52,8 18,1 2,9 48,5 18,5 2,6 45,7 19,2 2,4 12/7 61,1 17,2 3,5 58,1 17,8 3,3 56,3 18,8 3,0 51,1 19,1 2,7 46,8 19,6 2,4 13/8 62,3 17,4 3,6 59,5 18,0 3,3 56,0 18,8 3,0 53,3 20,0 2,7 50,0 20,5 2,4 14/9 65,7 18,0 3,6 61,1 18,5 3,3 57,7 19,1 3,0 53,4 19,8 2,7 50,8 20,7 2,5 15/10 65,5 18,0 3,6 62,7 18,8 3,3 59,8 19,7 3,0 56,0 20,6 2,7 51,5 21,1 2,4 17/12 69,7 18,7 3,7 67,9 20,1 3,4 62,7 20,4 3,1 58,8 21,3 2,8 54,1 21,9 2,5 19/14 75,6 19,8 3,8 71,8 20,6 3,5 66,6 21,5 3,1 62,2 22,3 2,8 58,1 23,2 2,5 21/16 78,1 20,2 3,9 76,0 21,7 3,5 71,1 22,6 3,1 65,5 23,3 2,8 60,9 24,1 2,5 23/18 82,9 21,4 3,9 77,9 21,9 3,6 73,4 23,1 3,2 68,7 24,6 2,8 - - - 45 6 55 COOLING AND HEATING CAPACITY 24 65 To: evaporator in/out water temperature [°C] Ta: External air temperature (Dry Bulb) [°C] kWF : cooling capacity [kW] (in conformity of EN14511) kWe: electrical power input in kW (in conformity of EN14511) The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. Ta [°C] 75 90 70 85 105 25 30 35 40 45 To [°C] KWF kWe EER KWF kWe EER KWF kWe EER KWF kWe EER KWF kWe EER 10/5 63,6 19,4 3,3 63,4 20,9 3,0 59,4 21,9 2,7 54,8 22,5 2,4 51,1 23,3 2,2 11/6 65,7 19,7 3,3 63,1 20,9 3,0 59,8 22,0 2,7 57,9 23,4 2,5 53,2 24,0 2,2 12/7 67,5 20,1 3,4 66,9 21,5 3,1 62,6 22,6 2,8 58,5 23,4 2,5 53,4 24,1 2,2 13/8 70,0 20,5 3,4 67,0 21,7 3,1 64,5 23,1 2,8 59,6 23,9 2,5 56,2 24,6 2,3 14/9 71,8 20,8 3,5 69,5 22,1 3,1 66,1 23,4 2,8 61,4 24,2 2,5 58,4 25,3 2,3 15/10 74,8 21,2 3,5 74,5 23,0 3,2 68,4 23,7 2,9 63,1 24,8 2,5 59,4 25,7 2,3 17/12 79,8 22,0 3,6 75,5 23,5 3,2 75,3 25,2 3,0 68,5 25,7 2,7 62,6 26,7 2,3 19/14 84,0 22,6 3,7 80,1 23,9 3,4 76,3 25,4 3,0 71,8 26,8 2,7 67,1 27,9 2,4 21/16 88,7 23,3 3,8 85,1 24,9 3,4 80,2 26,1 3,1 76,2 27,7 2,7 71,8 29,0 2,5 23/18 92,6 23,8 3,9 89,8 25,6 3,5 85,3 27,2 3,1 80,6 28,7 2,8 - - - 10/5 77,6 23,5 3,3 75,1 24,7 3,0 70,5 25,9 2,7 65,8 26,9 2,4 60,3 27,5 2,2 11/6 80,8 24,0 3,4 76,7 25,2 3,0 74,0 26,7 2,8 68,4 27,5 2,5 61,9 27,8 2,2 12/7 83,0 24,5 3,4 79,3 25,7 3,1 74,3 27,1 2,7 69,3 27,8 2,5 64,3 28,6 2,2 13/8 86,9 25,1 3,5 82,4 26,2 3,1 77,3 27,2 2,8 72,3 28,8 2,5 66,3 29,3 2,3 14/9 88,6 25,3 3,5 84,7 26,7 3,2 79,7 28,1 2,8 73,3 29,1 2,5 68,6 29,9 2,3 15/10 95,0 26,4 3,6 86,3 27,0 3,2 82,8 28,7 2,9 75,9 29,5 2,6 72,5 31,3 2,3 17/12 95,8 26,5 3,6 94,0 28,4 3,3 87,1 29,6 2,9 81,2 30,7 2,6 75,2 31,8 2,4 19/14 104,0 27,9 3,7 98,5 29,3 3,4 93,4 30,8 3,0 87,0 32,0 2,7 79,4 33,0 2,4 21/16 110,2 29,0 3,8 102,8 30,1 3,4 97,1 31,6 3,1 90,4 33,0 2,7 86,2 34,9 2,5 23/18 114,6 29,7 3,9 110,3 31,3 3,5 104,3 32,9 3,2 95,7 34,1 2,8 - - - 10/5 61,9 18,8 3,3 58,5 19,5 3,0 57,7 20,8 2,8 53,6 21,7 2,5 49,5 21,9 2,3 11/6 62,6 18,6 3,4 61,3 19,7 3,1 58,8 21,2 2,8 56,3 22,3 2,5 51,9 22,8 2,3 12/7 65,0 19,2 3,4 63,6 20,5 3,1 61,3 21,4 2,9 56,1 22,3 2,5 54,8 23,4 2,3 13/8 67,3 19,5 3,4 65,2 20,7 3,1 62,7 21,7 2,9 59,3 23,0 2,6 56,1 23,6 2,4 14/9 69,4 19,9 3,5 67,6 21,2 3,2 63,6 22,1 2,9 61,0 23,5 2,6 55,6 23,8 2,3 15/10 71,2 20,2 3,5 69,0 21,5 3,2 66,1 22,6 2,9 62,1 23,7 2,6 58,9 24,7 2,4 17/12 75,7 20,9 3,6 73,3 21,9 3,3 68,5 23,1 3,0 67,4 24,5 2,7 62,3 25,5 2,4 19/14 81,1 21,7 3,7 77,4 22,8 3,4 73,6 23,9 3,1 69,5 25,4 2,7 65,8 26,4 2,5 21/16 85,5 22,3 3,8 81,7 23,7 3,4 78,8 25,0 3,2 71,9 25,9 2,8 68,8 27,2 2,5 23/18 89,2 23,1 3,9 84,9 24,1 3,5 82,7 25,7 3,2 77,8 27,1 2,9 - - - 10/5 74,9 22,9 3,3 71,0 23,9 3,0 67,4 24,8 2,7 63,3 25,6 2,5 59,3 26,5 2,2 11/6 76,7 23,3 3,3 74,5 24,7 3,0 69,8 25,3 2,8 64,8 26,2 2,5 60,3 26,9 2,2 12/7 79,1 23,7 3,3 75,3 24,5 3,1 71,3 25,9 2,8 68,3 26,8 2,6 63,1 27,4 2,3 13/8 83,2 24,3 3,4 79,1 25,4 3,1 74,0 26,4 2,8 70,2 27,4 2,6 64,7 28,0 2,3 14/9 84,6 24,9 3,4 82,2 25,8 3,2 77,6 26,9 2,9 70,2 27,6 2,5 66,1 28,0 2,4 15/10 87,6 25,0 3,5 83,3 26,1 3,2 79,0 27,1 2,9 74,3 28,3 2,6 70,5 29,7 2,4 17/12 91,8 25,8 3,6 87,0 27,0 3,2 82,8 28,0 3,0 78,9 29,4 2,7 72,1 30,1 2,4 19/14 98,9 26,8 3,7 92,9 27,9 3,3 88,8 29,2 3,0 83,0 30,5 2,7 77,2 31,5 2,5 21/16 102,6 27,5 3,7 100,0 29,0 3,5 94,5 30,3 3,1 87,6 31,4 2,8 81,9 32,7 2,5 23/18 107,9 28,3 3,8 102,5 29,5 3,5 98,9 31,3 3,2 91,3 32,4 2,8 - - - 10/5 93,9 28,9 3,3 88,4 29,8 3,0 83,4 30,5 2,7 80,9 32,3 2,5 71,8 32,2 2,2 11/6 97,0 29,5 3,3 92,5 30,3 3,0 86,5 31,4 2,8 84,8 33,0 2,6 75,2 32,8 2,3 12/7 99,7 29,8 3,3 94,4 31,0 3,1 90,6 32,3 2,8 84,2 33,0 2,6 76,4 33,6 2,3 13/8 103,3 30,3 3,4 97,8 31,6 3,1 95,5 32,9 2,9 89,5 34,3 2,6 81,1 35,2 2,3 14/9 106,2 31,0 3,4 101,0 32,1 3,1 96,1 33,5 2,9 88,9 34,3 2,6 81,5 34,9 2,3 15/10 110,4 31,6 3,5 104,3 32,6 3,2 101,4 34,3 3,0 92,7 35,0 2,6 85,8 36,0 2,4 17/12 117,5 32,7 3,6 112,6 34,0 3,3 105,7 35,3 3,0 95,2 35,9 2,7 91,1 37,2 2,4 19/14 124,1 33,6 3,7 117,6 34,9 3,4 114,5 36,6 3,1 107,5 37,9 2,8 96,4 38,6 2,5 21/16 131,0 34,8 3,8 129,1 36,6 3,5 118,2 37,7 3,1 110,3 38,9 2,8 100,3 39,6 2,5 23/18 137,6 35,9 3,8 132,9 37,4 3,6 124,4 38,6 3,2 115,8 40,0 2,9 - - - To: evaporator in/out water temperature [°C] Ta: External air temperature (Dry Bulb) [°C] kWF : cooling capacity [kW] (in conformity of EN14511) kWe: electrical power input in kW (in conformity of EN14511) The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. Technical book black ht 6 COOLING AND HEATING CAPACITY 25 Ta [°C] 125 145 Technical book Black ht 6 180 COOLING AND HEATING CAPACITY 200 26 235 25 30 35 40 45 To [°C] KWF kWe EER KWF kWe EER KWF kWe EER KWF kWe EER KWF kWe EER 10/5 104,3 30,5 3,4 99,7 31,8 3,1 94,8 32,8 2,9 89,2 34,3 2,6 81,7 35,1 2,3 11/6 107,8 31,1 3,5 103,5 32,5 3,2 97,7 33,8 2,9 91,8 35,0 2,6 84,6 36,0 2,3 12/7 111,1 31,8 3,5 106,8 33,3 3,2 100,7 34,6 2,9 93,4 35,6 2,6 87,3 36,7 2,4 13/8 113,0 32,3 3,5 108,1 33,6 3,2 104,7 35,4 3,0 97,0 36,5 2,7 90,9 38,2 2,4 14/9 117,9 33,2 3,6 113,7 34,7 3,3 107,8 36,2 3,0 100,0 37,5 2,7 94,0 38,9 2,4 15/10 126,0 34,7 3,6 116,8 35,3 3,3 111,2 36,9 3,0 103,7 38,4 2,7 95,7 39,5 2,4 17/12 132,7 36,0 3,7 124,2 36,7 3,4 117,2 38,4 3,0 109,6 40,0 2,7 102,4 41,6 2,5 19/14 140,0 37,5 3,7 130,5 38,2 3,4 124,0 40,2 3,1 116,0 41,8 2,8 107,0 43,2 2,5 21/16 142,6 37,9 3,8 137,6 39,6 3,5 131,9 42,2 3,1 122,3 43,6 2,8 117,9 46,8 2,5 23/18 155,9 40,4 3,9 148,7 42,1 3,5 136,3 43,3 3,1 127,6 45,4 2,8 - - - 10/5 124,3 39,2 3,2 118,9 40,7 2,9 113,3 43,1 2,6 104,9 44,4 2,4 98,6 45,3 2,2 11/6 129,9 39,9 3,3 121,5 41,8 2,9 116,3 43,4 2,7 109,6 45,5 2,4 103,6 47,4 2,2 12/7 133,0 40,7 3,3 126,7 42,9 3,0 120,2 44,9 2,7 113,5 46,3 2,5 106,0 47,9 2,2 13/8 138,3 41,6 3,3 130,9 43,3 3,0 125,1 45,4 2,8 115,9 47,4 2,4 108,8 49,3 2,2 14/9 142,3 42,4 3,4 135,4 44,4 3,0 128,3 46,6 2,8 122,5 48,5 2,5 112,3 50,1 2,2 15/10 146,0 43,0 3,4 139,2 45,0 3,1 133,4 47,9 2,8 123,7 49,0 2,5 115,5 51,2 2,3 17/12 154,5 44,5 3,5 148,3 47,0 3,2 140,2 49,3 2,8 131,6 51,4 2,6 121,7 53,1 2,3 19/14 164,5 46,1 3,6 157,8 48,8 3,2 149,4 51,0 2,9 138,7 53,2 2,6 129,2 55,4 2,3 21/16 175,6 48,3 3,6 164,6 50,3 3,3 155,4 52,8 2,9 145,7 55,1 2,6 136,3 57,5 2,4 23/18 181,7 49,3 3,7 172,6 51,9 3,3 164,1 54,6 3,0 154,2 57,6 2,7 - - - 10/5 145,5 45,7 3,2 143,2 48,8 2,9 133,7 50,4 2,7 125,5 52,2 2,4 117,6 54,1 2,2 11/6 152,0 47,2 3,2 144,2 48,9 2,9 137,9 50,9 2,7 129,2 53,4 2,4 122,7 55,7 2,2 12/7 157,4 48,1 3,3 150,1 50,1 3,0 145,2 52,3 2,8 134,3 54,6 2,5 126,5 56,9 2,2 13/8 161,5 48,7 3,3 154,3 51,5 3,0 146,6 53,1 2,8 136,2 55,3 2,5 128,2 57,5 2,2 14/9 167,5 50,0 3,4 160,3 52,2 3,1 153,8 54,5 2,8 142,5 56,3 2,5 134,0 59,2 2,3 15/10 170,3 50,9 3,3 164,8 53,1 3,1 156,5 55,5 2,8 147,6 58,2 2,5 134,0 59,5 2,3 17/12 179,6 52,3 3,4 174,3 54,7 3,2 165,8 57,6 2,9 153,8 59,9 2,6 142,4 61,9 2,3 19/14 193,2 54,6 3,5 182,2 56,6 3,2 173,9 59,3 2,9 164,8 62,6 2,6 150,8 64,5 2,3 21/16 197,2 55,7 3,5 192,5 58,6 3,3 181,1 61,3 3,0 173,0 64,6 2,7 160,3 67,1 2,4 23/18 216,0 58,7 3,7 200,3 60,3 3,3 195,7 64,6 3,0 177,4 66,1 2,7 - - - 10/5 180,5 57,5 3,1 169,6 59,7 2,8 160,8 62,3 2,6 149,7 64,2 2,3 137,5 65,5 2,1 11/6 183,7 58,1 3,2 177,1 61,0 2,9 165,7 63,4 2,6 153,7 65,4 2,4 143,4 67,1 2,1 12/7 190,2 59,4 3,2 182,4 62,2 2,9 173,8 65,2 2,7 163,5 67,8 2,4 148,6 68,4 2,2 13/8 196,8 60,9 3,2 186,8 63,2 3,0 178,9 66,4 2,7 163,5 68,0 2,4 153,4 70,0 2,2 14/9 204,2 62,2 3,3 194,5 64,8 3,0 182,7 67,1 2,7 171,1 69,6 2,5 157,0 71,3 2,2 15/10 211,6 64,2 3,3 198,8 65,7 3,0 189,1 68,5 2,8 174,0 70,7 2,5 164,6 73,3 2,2 17/12 223,8 65,9 3,4 209,5 67,7 3,1 199,3 71,2 2,8 185,7 73,6 2,5 170,6 75,3 2,3 19/14 235,2 67,6 3,5 223,3 70,8 3,2 207,6 72,7 2,9 193,5 75,4 2,6 180,0 77,8 2,3 21/16 250,2 70,1 3,6 236,3 74,3 3,2 219,1 75,7 2,9 206,3 78,5 2,6 192,5 81,3 2,4 23/18 257,6 72,2 3,6 251,1 76,4 3,3 233,2 78,9 3,0 217,0 81,7 2,7 - - - 10/5 214,2 70,2 3,0 201,1 72,1 2,8 190,7 75,2 2,5 174,5 77,4 2,3 161,3 79,4 2,0 11/6 218,5 71,0 3,1 207,6 73,6 2,8 192,7 76,0 2,5 179,0 78,7 2,3 165,8 81,2 2,0 12/7 228,8 73,1 3,1 213,1 74,7 2,9 201,1 78,0 2,6 185,5 80,3 2,3 171,5 82,9 2,1 13/8 236,5 75,4 3,1 220,3 76,7 2,9 207,6 80,1 2,6 192,1 82,3 2,3 178,7 85,2 2,1 14/9 234,1 74,9 3,1 227,6 78,2 2,9 213,0 80,9 2,6 198,0 83,8 2,4 184,6 87,1 2,1 15/10 250,2 77,1 3,2 233,2 79,4 2,9 218,6 82,9 2,6 205,1 86,0 2,4 188,8 88,2 2,1 17/12 260,4 79,5 3,3 250,4 83,4 3,0 230,5 85,8 2,7 215,9 89,1 2,4 199,9 92,0 2,2 19/14 274,0 82,2 3,3 260,5 86,1 3,0 245,7 90,5 2,7 226,8 92,8 2,4 209,9 95,7 2,2 21/16 289,9 85,9 3,4 278,5 90,4 3,1 254,2 93,3 2,7 237,6 97,9 2,4 223,5 100,8 2,2 23/18 305,4 88,4 3,5 285,0 92,2 3,1 270,9 97,7 2,8 251,0 101,3 2,5 - - - To: evaporator in/out water temperature [°C] Ta: External air temperature (Dry Bulb) [°C] kWF : cooling capacity [kW] (in conformity of EN14511) kWe: electrical power input in kW (in conformity of EN14511) The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. HEATING CAPACITY Ta [°C] / RH MOD. To [°C] -15 / 90 -10 / 90 -5 / 80 0 / 80 5 / 80 7 / 80 KWT kWe COP KWT kWe COP KWT kWe COP KWT kWe COP KWT kWe COP KWT kWe COP 40 45 55 65 75 90 70 30/35 35/40 40/45 45/50 50/55 55/60 60/65 65/70 70/75 30/35 35/40 40/45 45/50 50/55 55/60 60/65 65/70 70/75 30/35 35/40 40/45 45/50 50/55 55/60 60/65 65/70 70/75 30/35 35/40 40/45 45/50 50/55 55/60 60/65 65/70 70/75 30/35 35/40 40/45 45/50 50/55 55/60 60/65 65/70 70/75 30/35 35/40 40/45 45/50 50/55 55/60 60/65 65/70 70/75 30/35 35/40 40/45 45/50 50/55 55/60 60/65 65/70 70/75 16,6 15,8 15,0 14,2 13,2 12,4 19,9 18,8 17,8 16,6 15,7 14,7 23,4 22,0 20,6 19,0 17,6 16,1 29,1 27,9 26,5 25,3 24,0 22,6 34,7 33,1 31,3 29,6 27,5 25,9 40,2 38,7 37,2 35,2 33,3 31,5 33,0 31,4 29,9 28,0 26,4 24,6 - 6,667 6,8 6,9 7,0 7,1 7,1 8,012 8,0 8,0 8,0 8,0 7,9 9,342 9,4 9,4 9,4 9,3 9,2 9,421 9,7 9,9 10,1 10,3 10,5 13,08 13,4 13,5 13,7 13,8 13,9 15,08 15,4 15,7 15,9 16,0 16,1 12,88 13,1 13,4 13,5 13,7 13,8 - To: Condenser in/out water temperature [°C] Ta: External air temperature (Dry Bulb) [°C] RH: relative humidity [%] 2,5 2,3 2,2 2,0 1,9 1,7 2,5 2,3 2,2 2,1 2,0 1,9 2,5 2,3 2,2 2,0 1,9 1,8 3,1 2,9 2,7 2,5 2,3 2,2 2,7 2,5 2,3 2,2 2,0 1,9 2,7 2,5 2,4 2,2 2,1 2,0 2,6 2,4 2,2 2,1 1,9 1,8 - 20,1 19,2 20,5 17,6 16,8 15,9 16,4 24,0 23,0 24,3 20,7 19,6 18,5 19,4 29,3 27,8 29,7 24,6 23,0 21,4 22,3 35,0 33,8 34,0 30,9 29,6 28,1 27,0 42,2 40,8 40,7 37,5 35,4 33,2 32,5 50,0 48,0 46,4 43,8 41,6 39,7 34,9 40,6 38,9 37,2 35,7 33,6 31,9 29,6 - 7,344 7,5 8,2 7,9 8,0 8,1 8,7 8,795 8,9 9,6 9,0 9,0 9,0 9,7 10,47 10,6 11,5 10,8 10,8 10,7 11,4 10,51 10,9 12,0 11,4 11,7 11,9 12,7 14,61 15,0 16,1 15,7 15,9 16,1 16,3 16,92 17,4 18,4 18,1 18,4 18,6 18,2 14,32 14,7 15,0 15,3 15,6 15,8 15,9 - 2,7 2,6 2,5 2,2 2,1 2,0 1,9 2,7 2,6 2,5 2,3 2,2 2,0 2,0 2,8 2,6 2,6 2,3 2,1 2,0 2,0 3,3 3,1 2,8 2,7 2,5 2,4 2,1 2,9 2,7 2,5 2,4 2,2 2,1 2,0 3,0 2,8 2,5 2,4 2,3 2,1 1,9 2,8 2,6 2,5 2,3 2,2 2,0 1,9 - 24,2 23,5 22,3 21,5 20,5 19,3 18,2 17,2 16,1 29,2 28,0 26,2 25,5 24,3 23,0 21,4 20,6 19,5 36,2 34,1 32,5 30,8 28,9 27,2 25,4 23,6 21,7 42,1 40,8 39,2 37,8 36,2 34,7 32,0 31,2 29,5 51,3 49,4 46,6 45,6 43,7 41,6 38,1 37,1 34,5 60,4 57,9 54,1 53,6 51,0 48,6 42,3 43,5 40,7 49,0 47,4 45,6 43,9 41,9 39,6 37,2 35,2 32,8 8,118 8,4 8,6 8,8 9,0 9,1 9,3 9,4 9,5 9,7 9,9 10,0 10,2 10,3 10,4 10,4 10,5 10,6 11,67 11,8 12,1 12,2 12,3 12,3 12,4 12,3 12,1 11,75 12,2 13,0 13,0 13,3 13,6 14,1 14,2 14,5 16,31 16,8 17,4 17,7 18,1 18,5 18,2 19,0 19,1 18,7 19,3 19,9 20,4 20,8 21,2 20,5 21,7 21,8 15,82 16,3 16,8 17,2 17,6 17,9 18,1 18,4 18,7 3,0 2,8 2,6 2,4 2,3 2,1 2,0 1,8 1,7 3,0 2,8 2,6 2,5 2,4 2,2 2,1 2,0 1,8 3,1 2,9 2,7 2,5 2,4 2,2 2,0 1,9 1,8 3,6 3,3 3,0 2,9 2,7 2,5 2,3 2,2 2,0 3,1 2,9 2,7 2,6 2,4 2,3 2,1 2,0 1,8 3,2 3,0 2,7 2,6 2,5 2,3 2,1 2,0 1,9 3,1 2,9 2,7 2,5 2,4 2,2 2,1 1,9 1,8 28,9 27,9 27,0 25,9 24,6 23,5 22,3 21,1 19,9 34,8 33,5 32,2 30,8 29,4 28,0 26,5 25,1 23,9 43,5 41,7 39,9 37,6 35,7 33,8 31,9 29,6 27,5 50,3 48,8 47,1 45,6 43,9 42,0 39,9 38,0 36,1 61,4 59,2 57,4 54,7 52,5 50,0 47,9 45,1 42,4 72,4 70,2 67,1 64,3 61,4 58,8 55,5 52,6 49,7 58,8 57,0 54,8 52,4 50,0 47,7 45,5 42,8 40,4 8,831 9,1 9,5 9,7 9,9 10,2 10,4 10,6 10,8 10,55 10,8 11,1 11,3 11,5 11,7 11,8 12,0 12,1 12,74 13,1 13,4 13,6 13,8 14,0 14,1 14,1 14,1 13,02 13,6 14,1 14,6 15,1 15,5 15,8 16,3 16,6 17,93 18,6 19,3 19,8 20,4 20,8 21,3 21,6 21,9 20,56 21,4 22,1 22,8 23,4 24,0 24,4 24,7 25,1 17,31 18,0 18,5 19,0 19,5 20,0 20,4 20,8 21,1 3,3 3,1 2,9 2,7 2,5 2,3 2,1 2,0 1,8 3,3 3,1 2,9 2,7 2,6 2,4 2,2 2,1 2,0 3,4 3,2 3,0 2,8 2,6 2,4 2,3 2,1 2,0 3,9 3,6 3,3 3,1 2,9 2,7 2,5 2,3 2,2 3,4 3,2 3,0 2,8 2,6 2,4 2,2 2,1 1,9 3,5 3,3 3,0 2,8 2,6 2,5 2,3 2,1 2,0 3,4 3,2 3,0 2,8 2,6 2,4 2,2 2,1 1,9 33,9 32,9 31,6 30,5 29,1 27,9 26,5 25,1 23,8 40,9 39,3 37,8 36,3 34,8 33,2 31,6 30,1 28,5 51,5 49,7 47,6 45,3 43,1 40,7 38,6 36,2 33,8 58,9 57,3 55,6 53,7 51,5 49,6 47,3 45,3 43,0 72,0 69,7 67,3 64,9 62,5 59,8 57,0 54,0 51,0 85,6 82,9 79,7 76,3 72,9 69,7 66,5 62,9 59,5 69,3 67,3 64,8 62,2 59,8 56,9 54,3 51,4 48,5 9,57 10,0 10,3 10,7 11,0 11,3 11,6 11,9 12,1 11,44 11,8 12,2 12,5 12,8 13,1 13,3 13,5 13,8 13,84 14,4 14,8 15,1 15,5 15,7 15,9 16,0 16,1 14,25 15,0 15,6 16,3 16,8 17,4 17,9 18,5 19,0 19,49 20,4 21,3 22,1 22,8 23,4 24,0 24,5 24,9 22,38 23,5 24,4 25,3 26,1 26,8 27,5 28,0 28,5 18,78 19,7 20,4 21,1 21,7 22,3 22,9 23,3 23,7 3,5 3,3 3,1 2,8 2,6 2,5 2,3 2,1 2,0 3,6 3,3 3,1 2,9 2,7 2,5 2,4 2,2 2,1 3,7 3,5 3,2 3,0 2,8 2,6 2,4 2,3 2,1 4,1 3,8 3,6 3,3 3,1 2,8 2,6 2,5 2,3 3,7 3,4 3,2 2,9 2,7 2,6 2,4 2,2 2,0 3,8 3,5 3,3 3,0 2,8 2,6 2,4 2,2 2,1 3,7 3,4 3,2 3,0 2,8 2,6 2,4 2,2 2,0 36,1 35,0 33,6 32,4 31,1 29,6 28,2 26,8 25,3 43,4 42,0 40,3 38,7 37,1 35,4 33,7 32,1 30,5 55,0 53,1 51,0 48,5 46,2 43,6 41,2 38,8 36,4 62,4 60,7 59,2 57,2 55,0 52,8 50,4 47,9 45,8 76,4 74,4 71,7 69,1 66,5 63,8 60,5 57,7 54,6 91,5 88,6 84,9 81,6 77,9 74,6 70,8 67,1 63,1 73,8 71,6 68,8 66,2 63,7 60,6 57,9 54,8 51,8 9,88 10,3 10,7 11,1 11,4 11,7 12,0 12,2 12,5 11,76 12,2 12,6 13,0 13,3 13,6 13,9 14,1 14,3 14,29 14,9 15,3 15,7 16,1 16,3 16,5 16,6 16,7 14,73 15,5 16,3 17,0 17,6 18,2 18,7 19,2 19,8 20,09 21,1 22,0 22,8 23,5 24,2 24,7 25,4 25,9 23,16 24,4 25,3 26,3 27,1 27,8 28,5 29,0 29,4 19,35 20,3 21,0 21,7 22,3 22,9 23,4 23,9 24,4 kWF : cooling capacity [kW] (in conformity of EN14511) kWe: electrical power input in kW (in conformity of EN14511) The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. 3,7 3,4 3,1 2,9 2,7 2,5 2,4 2,2 2,0 3,7 3,4 3,2 3,0 2,8 2,6 2,4 2,3 2,1 3,8 3,6 3,3 3,1 2,9 2,7 2,5 2,3 2,2 4,2 3,9 3,6 3,4 3,1 2,9 2,7 2,5 2,3 3,8 3,5 3,3 3,0 2,8 2,6 2,4 2,3 2,1 4,0 3,6 3,4 3,1 2,9 2,7 2,5 2,3 2,1 3,8 3,5 3,3 3,1 2,9 2,6 2,5 2,3 2,1 Technical book black ht 6 COOLING AND HEATING CAPACITY 27 Ta [°C] / RH MOD. To [°C] -15 / 90 -10 / 90 -5 / 80 0 / 80 5 / 80 7 / 80 KWT kWe COP KWT kWe COP KWT kWe COP KWT kWe COP KWT kWe COP KWT kWe COP 85 105 125 Technical book Black ht 6 COOLING AND HEATING CAPACITY 145 180 28 200 235 30/35 38,7 16,09 35/40 36,7 16,1 40/45 34,7 16,2 45/50 32,6 16,1 50/55 30,6 16,0 55/60 28,6 15,9 60/65 65/70 70/75 30/35 47,4 19,55 35/40 44,2 19,6 40/45 41,9 19,8 45/50 38,7 19,7 50/55 35,5 19,5 55/60 32,5 19,2 60/65 65/70 70/75 30/35 58,7 18,94 35/40 56,4 19,5 40/45 53,9 20,0 45/50 51,3 20,4 50/55 48,2 20,7 55/60 45,5 21,1 60/65 65/70 70/75 30/35 69,7 24,77 35/40 66,6 25,3 40/45 63,1 25,8 45/50 59,8 26,2 50/55 56,2 26,5 55/60 52,5 26,7 60/65 65/70 70/75 30/35 86,4 30,6 35/40 83,5 31,5 40/45 79,5 32,0 45/50 75,6 32,4 50/55 71,5 32,7 55/60 67,1 32,8 60/65 65/70 70/75 30/35 99,4 37,25 35/40 93,9 37,9 40/45 88,8 38,4 45/50 84,1 38,8 50/55 79,3 39,1 55/60 73,5 38,9 60/65 65/70 70/75 30/35 110,2 42,87 35/40 105,9 43,7 40/45 101,1 44,4 45/50 97,0 45,1 50/55 92,5 45,6 55/60 88,1 46,0 60/65 65/70 70/75 - 2,4 2,3 2,1 2,0 1,9 1,8 2,4 2,3 2,1 2,0 1,8 1,7 3,1 2,9 2,7 2,5 2,3 2,2 2,8 2,6 2,4 2,3 2,1 2,0 2,8 2,7 2,5 2,3 2,2 2,0 2,7 2,5 2,3 2,2 2,0 1,9 2,6 2,4 2,3 2,2 2,0 1,9 - 47,8 45,7 43,4 41,4 39,0 36,7 34,6 59,5 56,2 53,0 50,4 46,8 43,3 39,8 71,3 69,0 66,1 63,5 60,6 57,7 54,6 84,5 81,1 77,7 74,2 70,4 67,2 63,5 103,8 99,7 95,7 91,1 87,0 82,3 77,8 119,9 116,2 111,3 105,1 99,7 93,6 87,3 135,4 131,2 125,5 119,6 114,7 109,2 105,0 - 17,83 18,1 18,2 18,4 18,4 18,4 18,4 21,87 22,2 22,4 22,6 22,6 22,5 22,2 21,29 22,0 22,6 23,2 23,7 24,2 24,6 27,72 28,5 29,2 29,8 30,3 30,8 31,3 33,86 34,9 35,8 36,4 37,0 37,4 37,7 41,34 42,7 43,7 44,3 44,9 45,1 45,1 47,67 49,2 50,1 50,9 51,9 52,6 53,6 - 2,7 2,5 2,4 2,3 2,1 2,0 1,9 2,7 2,5 2,4 2,2 2,1 1,9 1,8 3,3 3,1 2,9 2,7 2,6 2,4 2,2 3,0 2,8 2,7 2,5 2,3 2,2 2,0 3,1 2,9 2,7 2,5 2,3 2,2 2,1 2,9 2,7 2,5 2,4 2,2 2,1 1,9 2,8 2,7 2,5 2,4 2,2 2,1 2,0 - 58,1 55,6 53,0 50,8 48,5 45,9 43,4 41,1 38,7 72,9 69,7 66,1 63,0 59,2 55,6 51,7 48,2 44,3 85,6 82,9 79,8 76,8 73,8 70,5 67,3 63,4 59,9 102,2 98,8 94,8 91,3 87,3 82,7 78,4 74,1 69,5 124,7 119,8 115,0 110,7 105,6 100,5 95,0 89,6 84,1 144,1 139,8 134,7 128,5 122,2 115,8 109,2 102,4 94,6 163,6 158,3 152,7 147,0 140,3 134,3 128,2 123,1 117,0 19,64 20,0 20,3 20,7 20,9 21,1 21,3 21,4 21,5 24,21 24,8 25,2 25,6 25,8 26,0 25,9 25,8 25,6 23,76 24,7 25,5 26,2 26,9 27,6 28,2 28,7 29,3 30,98 32,1 33,0 34,0 34,7 35,3 35,9 36,5 36,9 37,48 38,8 40,0 41,1 42,0 42,7 43,3 43,8 44,0 45,76 47,5 48,9 50,0 51,0 51,6 52,1 52,3 52,0 52,57 54,3 56,0 57,5 58,8 60,0 61,1 62,4 63,2 3,0 2,8 2,6 2,5 2,3 2,2 2,0 1,9 1,8 3,0 2,8 2,6 2,5 2,3 2,1 2,0 1,9 1,7 3,6 3,4 3,1 2,9 2,7 2,6 2,4 2,2 2,0 3,3 3,1 2,9 2,7 2,5 2,3 2,2 2,0 1,9 3,3 3,1 2,9 2,7 2,5 2,4 2,2 2,0 1,9 3,1 2,9 2,8 2,6 2,4 2,2 2,1 2,0 1,8 3,1 2,9 2,7 2,6 2,4 2,2 2,1 2,0 1,9 70,0 67,3 64,4 61,6 58,5 56,0 53,3 50,3 47,8 88,7 84,9 80,4 77,3 72,9 69,1 64,8 60,4 56,1 101,5 98,8 95,7 92,1 89,0 85,2 81,0 77,2 73,1 121,8 117,9 113,9 109,7 105,3 100,7 95,8 91,0 85,7 147,4 142,1 137,6 131,5 126,1 120,3 113,9 108,0 101,7 173,0 167,5 161,3 154,8 148,2 141,2 133,5 125,2 116,5 196,6 190,6 184,3 177,5 169,7 162,9 156,6 150,0 142,4 21,45 22,1 22,6 23,1 23,4 23,9 24,2 24,5 24,8 26,62 27,4 28,0 28,7 29,0 29,4 29,6 29,6 29,6 26,28 27,5 28,5 29,4 30,4 31,3 32,1 33,0 33,7 34,18 35,6 36,9 38,1 39,3 40,2 41,1 41,9 42,7 41,02 42,8 44,4 45,8 47,1 48,3 49,1 49,9 50,5 50,36 52,5 54,4 56,0 57,3 58,4 59,3 59,8 59,9 57,79 60,1 62,3 64,4 66,2 67,9 69,8 71,4 72,7 3,3 3,1 2,9 2,7 2,5 2,3 2,2 2,1 1,9 3,3 3,1 2,9 2,7 2,5 2,3 2,2 2,0 1,9 3,9 3,6 3,4 3,1 2,9 2,7 2,5 2,3 2,2 3,6 3,3 3,1 2,9 2,7 2,5 2,3 2,2 2,0 3,6 3,3 3,1 2,9 2,7 2,5 2,3 2,2 2,0 3,4 3,2 3,0 2,8 2,6 2,4 2,3 2,1 1,9 3,4 3,2 3,0 2,8 2,6 2,4 2,2 2,1 2,0 82,8 79,7 76,4 72,8 69,9 66,8 63,6 60,5 57,2 104,7 101,2 97,0 92,5 87,8 83,7 78,9 73,9 68,5 119,0 115,9 112,0 109,1 104,8 100,0 96,2 91,7 87,5 143,6 139,0 134,8 129,7 125,1 119,6 114,0 108,5 103,0 172,1 166,3 161,0 155,0 147,9 141,4 135,1 128,2 120,8 203,2 196,4 189,8 183,4 176,2 167,4 159,7 150,6 140,9 234,0 226,6 218,9 211,2 203,6 194,7 186,6 178,4 170,4 23,21 24,1 24,8 25,4 26,1 26,7 27,3 27,7 28,1 28,79 29,9 30,9 31,7 32,4 33,0 33,4 33,7 33,7 28,77 30,3 31,5 32,9 34,1 35,1 36,4 37,3 38,5 37,2 39,1 40,9 42,4 44,0 45,3 46,4 47,6 48,8 44,58 46,8 48,8 50,7 52,3 53,8 55,3 56,5 57,4 54,76 57,3 59,7 61,9 63,7 65,2 66,8 67,6 68,1 62,96 66,0 68,8 71,5 74,1 76,3 78,5 80,8 82,6 3,6 3,3 3,1 2,9 2,7 2,5 2,3 2,2 2,0 3,6 3,4 3,1 2,9 2,7 2,5 2,4 2,2 2,0 4,1 3,8 3,6 3,3 3,1 2,8 2,6 2,5 2,3 3,9 3,6 3,3 3,1 2,8 2,6 2,5 2,3 2,1 3,9 3,6 3,3 3,1 2,8 2,6 2,4 2,3 2,1 3,7 3,4 3,2 3,0 2,8 2,6 2,4 2,2 2,1 3,7 3,4 3,2 3,0 2,7 2,6 2,4 2,2 2,1 88,2 85,0 81,5 78,0 74,5 71,2 67,8 64,3 61,0 112,2 108,0 103,8 98,9 94,1 89,2 84,2 79,4 74,2 126,8 123,8 120,1 115,8 112,0 107,2 102,5 97,5 93,0 151,9 148,1 143,0 138,6 133,1 127,6 121,5 115,8 110,1 183,9 176,9 171,2 164,9 158,1 150,8 143,3 135,6 128,2 216,3 209,5 202,3 196,0 187,6 178,5 169,9 161,7 150,6 251,2 243,6 234,4 227,4 219,2 209,6 200,1 191,5 182,6 23,93 24,9 25,7 26,4 27,0 27,6 28,2 28,7 29,1 29,75 30,9 32,0 32,9 33,6 34,2 34,6 34,9 35,1 29,8 31,5 32,9 34,3 35,7 36,8 38,0 39,0 40,1 38,36 40,5 42,3 44,2 45,7 47,1 48,4 49,5 50,7 46,11 48,4 50,6 52,7 54,6 56,2 57,5 58,5 59,5 56,53 59,4 61,9 64,4 66,3 67,9 69,3 70,5 70,8 65,1 68,5 71,4 74,7 77,5 80,0 82,3 84,6 86,7 To: Condenser in/out water temperature [°C] Ta: External air temperature (Dry Bulb) [°C] RH: relative humidity [%] kWF : cooling capacity [kW] (in conformity of EN14511) kWe: electrical power input in kW (in conformity of EN14511) The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. 3,7 3,4 3,2 3,0 2,8 2,6 2,4 2,2 2,1 3,8 3,5 3,2 3,0 2,8 2,6 2,4 2,3 2,1 4,3 3,9 3,6 3,4 3,1 2,9 2,7 2,5 2,3 4,0 3,7 3,4 3,1 2,9 2,7 2,5 2,3 2,2 4,0 3,7 3,4 3,1 2,9 2,7 2,5 2,3 2,2 3,8 3,5 3,3 3,0 2,8 2,6 2,5 2,3 2,1 3,9 3,6 3,3 3,0 2,8 2,6 2,4 2,3 2,1 Ta [°C] / RH MOD. To [°C] 10 / 70 15 / 70 20 / 60 25 / 60 30 / 50 35 / 50 KWT kWe COP KWT kWe COP KWT kWe COP KWT kWe COP KWT kWe COP KWT kWe COP 40 45 55 65 75 90 70 30/35 35/40 40/45 45/50 50/55 55/60 60/65 65/70 70/75 30/35 35/40 40/45 45/50 50/55 55/60 60/65 65/70 70/75 30/35 35/40 40/45 45/50 50/55 55/60 60/65 65/70 70/75 30/35 35/40 40/45 45/50 50/55 55/60 60/65 65/70 70/75 30/35 35/40 40/45 45/50 50/55 55/60 60/65 65/70 70/75 30/35 35/40 40/45 45/50 50/55 55/60 60/65 65/70 70/75 30/35 35/40 40/45 45/50 50/55 55/60 60/65 65/70 70/75 38,4 37,1 35,9 34,5 33,1 31,6 30,2 28,8 27,2 46,7 44,9 43,1 41,2 39,6 37,9 36,0 34,5 32,8 58,7 56,8 54,4 51,8 49,1 46,7 44,2 41,7 39,0 66,4 64,4 62,4 60,8 58,3 56,0 53,7 51,2 48,6 81,4 78,8 76,6 73,5 70,6 67,8 64,8 61,8 58,7 96,6 93,8 91,0 87,0 83,3 79,2 75,4 71,3 67,8 78,1 75,8 73,2 70,5 67,6 64,7 61,4 58,7 55,5 10,07 10,5 10,9 11,3 11,7 12,0 12,3 12,6 12,9 12,15 12,6 13,0 13,3 13,7 14,0 14,3 14,6 14,9 14,69 15,3 15,8 16,2 16,5 16,8 17,1 17,3 17,4 15,22 16,0 16,8 17,6 18,2 18,8 19,4 20,0 20,6 20,44 21,5 22,5 23,3 24,1 24,9 25,6 26,3 27,0 23,66 24,9 26,1 27,0 27,9 28,7 29,4 30,0 30,6 19,55 20,5 21,3 22,1 22,8 23,4 24,0 24,6 25,2 3,8 3,5 3,3 3,0 2,8 2,6 2,5 2,3 2,1 3,8 3,6 3,3 3,1 2,9 2,7 2,5 2,4 2,2 4,0 3,7 3,5 3,2 3,0 2,8 2,6 2,4 2,2 4,4 4,0 3,7 3,5 3,2 3,0 2,8 2,6 2,4 4,0 3,7 3,4 3,1 2,9 2,7 2,5 2,4 2,2 4,1 3,8 3,5 3,2 3,0 2,8 2,6 2,4 2,2 4,0 3,7 3,4 3,2 3,0 2,8 2,6 2,4 2,2 43,1 41,8 40,6 39,1 37,4 35,8 34,2 32,8 31,2 52,2 50,4 48,4 46,7 44,9 42,8 40,9 39,0 37,3 66,4 63,7 61,3 58,5 56,0 53,3 50,6 47,9 45,0 74,5 72,4 70,2 67,9 65,1 62,7 60,3 57,6 54,9 91,2 88,6 85,9 82,9 79,8 76,7 73,3 69,9 66,5 109,1 105,3 102,1 98,5 94,2 89,9 85,5 81,2 76,7 87,3 84,9 82,0 79,1 76,0 72,7 69,6 66,1 62,6 10,3 10,8 11,4 11,8 12,2 12,7 13,1 13,5 13,8 12,52 13,1 13,6 14,0 14,5 14,9 15,3 15,7 16,0 15,24 15,9 16,5 17,0 17,5 17,9 18,3 18,6 18,8 15,86 16,8 17,7 18,6 19,3 20,1 20,9 21,6 22,3 20,95 22,2 23,4 24,4 25,5 26,4 27,3 28,1 28,9 24,47 25,9 27,2 28,5 29,5 30,5 31,5 32,2 32,9 19,82 20,9 21,9 22,8 23,7 24,5 25,2 25,9 26,6 4,2 3,9 3,6 3,3 3,1 2,8 2,6 2,4 2,3 4,2 3,9 3,6 3,3 3,1 2,9 2,7 2,5 2,3 4,4 4,0 3,7 3,4 3,2 3,0 2,8 2,6 2,4 4,7 4,3 4,0 3,7 3,4 3,1 2,9 2,7 2,5 4,4 4,0 3,7 3,4 3,1 2,9 2,7 2,5 2,3 4,5 4,1 3,8 3,5 3,2 2,9 2,7 2,5 2,3 4,4 4,1 3,7 3,5 3,2 3,0 2,8 2,5 2,4 47,4 45,9 44,3 42,6 41,0 39,3 37,5 35,8 33,9 56,8 55,3 53,3 51,2 49,1 47,1 45,1 43,1 40,9 71,6 69,1 66,4 63,7 61,0 57,9 55,1 52,2 49,3 80,6 78,1 75,6 73,5 70,7 68,0 65,1 62,2 59,6 99,2 96,3 92,9 89,5 87,0 83,1 79,6 76,0 72,3 118,4 114,5 110,9 106,1 102,0 97,5 92,9 88,3 83,7 94,5 91,5 88,4 85,2 81,7 78,1 74,6 71,1 67,3 10,48 11,1 11,7 12,2 12,7 13,2 13,6 14,1 14,5 12,81 13,5 14,1 14,6 15,1 15,6 16,1 16,5 16,9 15,6 16,4 17,0 17,7 18,2 18,7 19,1 19,5 19,8 16,28 17,3 18,3 19,3 20,2 21,0 21,8 22,7 23,5 21,27 22,7 24,0 25,2 26,4 27,4 28,5 29,5 30,4 24,98 26,6 28,1 29,4 30,7 31,8 32,8 33,8 34,6 19,97 21,2 22,3 23,3 24,2 25,1 26,0 26,8 27,5 4,5 4,1 3,8 3,5 3,2 3,0 2,8 2,5 2,3 4,4 4,1 3,8 3,5 3,2 3,0 2,8 2,6 2,4 4,6 4,2 3,9 3,6 3,3 3,1 2,9 2,7 2,5 5,0 4,5 4,1 3,8 3,5 3,2 3,0 2,7 2,5 4,7 4,3 3,9 3,6 3,3 3,0 2,8 2,6 2,4 4,7 4,3 4,0 3,6 3,3 3,1 2,8 2,6 2,4 4,7 4,3 4,0 3,7 3,4 3,1 2,9 2,7 2,4 51,2 49,5 47,7 46,0 44,3 42,4 40,4 38,5 36,5 62,3 60,1 57,8 55,4 53,0 50,9 48,6 46,3 44,2 77,6 75,1 71,9 69,0 65,8 62,8 59,7 56,5 53,3 87,0 84,3 81,8 79,1 76,1 73,3 70,2 67,3 64,1 107,0 103,7 100,7 97,2 93,5 89,7 85,6 81,7 77,9 128,1 123,9 119,3 114,6 110,2 105,2 100,2 95,4 90,0 100,8 97,5 94,0 90,5 86,6 82,7 78,5 73,8 69,4 10,6 11,3 11,9 12,5 13,1 13,6 14,1 14,6 15,1 13,12 13,8 14,5 15,1 15,7 16,2 16,8 17,2 17,7 15,96 16,8 17,6 18,3 18,9 19,4 19,9 20,3 20,7 16,66 17,9 18,9 20,0 21,0 22,0 22,9 23,8 24,7 21,55 23,1 24,6 26,0 27,2 28,5 29,6 30,7 31,7 25,46 27,3 28,9 30,4 31,8 33,0 34,2 35,3 36,2 20,09 21,4 22,6 23,7 24,7 25,7 26,6 27,3 28,0 4,8 4,4 4,0 3,7 3,4 3,1 2,9 2,6 2,4 4,7 4,3 4,0 3,7 3,4 3,1 2,9 2,7 2,5 4,9 4,5 4,1 3,8 3,5 3,2 3,0 2,8 2,6 5,2 4,7 4,3 4,0 3,6 3,3 3,1 2,8 2,6 5,0 4,5 4,1 3,7 3,4 3,2 2,9 2,7 2,5 5,0 4,5 4,1 3,8 3,5 3,2 2,9 2,7 2,5 5,0 4,6 4,2 3,8 3,5 3,2 3,0 2,7 2,5 53,3 51,5 49,7 47,8 45,7 44,0 42,0 39,6 37,2 64,7 62,5 60,1 57,7 55,2 52,8 50,4 48,1 45,6 80,8 77,6 74,8 71,7 68,4 65,2 61,8 58,5 55,3 90,8 87,7 85,0 81,9 79,4 76,1 73,1 69,7 66,4 111,5 107,9 104,2 100,6 96,8 92,6 88,2 82,5 78,6 133,4 128,9 124,4 119,4 114,1 108,8 103,8 98,4 92,0 103,7 100,1 96,3 91,9 87,4 83,0 78,5 74,0 69,4 10,66 11,4 12,1 12,7 13,3 13,9 14,4 14,8 15,2 13,26 14,0 14,7 15,4 16,0 16,6 17,1 17,6 18,1 16,14 17,0 17,8 18,6 19,2 19,8 20,3 20,8 21,1 16,9 18,1 19,3 20,4 21,5 22,5 23,5 24,4 25,3 21,68 23,3 24,8 26,3 27,7 28,9 30,0 30,7 31,7 25,73 27,6 29,3 30,9 32,3 33,6 34,8 35,9 36,6 20,13 21,5 22,7 23,8 24,8 25,7 26,5 27,3 28,0 5,0 4,5 4,1 3,8 3,4 3,2 2,9 2,7 2,4 4,9 4,5 4,1 3,8 3,5 3,2 2,9 2,7 2,5 5,0 4,6 4,2 3,9 3,6 3,3 3,0 2,8 2,6 5,4 4,8 4,4 4,0 3,7 3,4 3,1 2,9 2,6 5,1 4,6 4,2 3,8 3,5 3,2 2,9 2,7 2,5 5,2 4,7 4,2 3,9 3,5 3,2 3,0 2,7 2,5 5,2 4,7 4,2 3,9 3,5 3,2 3,0 2,7 2,5 55,8 53,5 51,3 49,0 46,2 44,6 42,8 40,2 37,9 68,2 65,9 63,1 60,2 57,1 54,2 51,4 49,3 46,8 85,0 81,6 78,3 75,2 71,7 67,5 62,2 59,5 55,8 95,6 92,6 89,6 86,3 83,0 79,8 76,3 72,2 68,1 115,0 111,5 107,0 102,4 97,7 93,0 88,2 83,4 78,6 139,7 135,0 129,7 123,6 117,3 110,9 103,8 98,6 92,0 104,5 100,4 96,2 91,9 87,1 83,0 78,5 9,6 69,4 10,73 11,5 12,1 12,7 13,8 14,2 14,9 15,0 15,6 13,43 14,2 15,0 15,7 16,2 16,7 17,5 17,9 18,6 16,34 17,3 18,2 18,9 19,6 20,1 20,5 20,8 21,8 17,14 18,4 19,7 20,9 22,0 23,1 24,1 24,9 25,7 21,58 23,4 24,9 26,3 27,6 28,7 29,7 30,7 31,5 26,03 28,0 29,8 31,3 32,6 33,8 34,5 36,0 36,3 20,13 21,5 22,7 23,8 24,6 25,7 26,4 3,3 28,0 To: Condenser in/out water temperature [°C] Ta: External air temperature (Dry Bulb) [°C] RH: relative humidity [%] kWF : cooling capacity [kW] (in conformity of EN14511) kWe: electrical power input in kW (in conformity of EN14511) The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. 5,2 4,7 4,2 3,8 3,3 3,1 2,9 2,7 2,4 5,1 4,6 4,2 3,8 3,5 3,2 2,9 2,8 2,5 5,2 4,7 4,3 4,0 3,7 3,4 3,0 2,9 2,6 5,6 5,0 4,5 4,1 3,8 3,5 3,2 2,9 2,7 5,3 4,8 4,3 3,9 3,5 3,2 3,0 2,7 2,5 5,4 4,8 4,4 4,0 3,6 3,3 3,0 2,7 2,5 5,2 4,7 4,2 3,9 3,5 3,2 3,0 3,0 2,5 Technical book black ht 6 COOLING AND HEATING CAPACITY 29 Ta [°C] / RH MOD. To [°C] 10 / 70 15 / 70 20 / 60 25 / 60 30 / 50 35 / 50 KWT kWe COP KWT kWe COP KWT kWe COP KWT kWe COP KWT kWe COP KWT kWe COP 85 105 125 Technical book Black ht 6 COOLING AND HEATING CAPACITY 145 180 30 200 235 30/35 35/40 40/45 45/50 50/55 55/60 60/65 65/70 70/75 30/35 35/40 40/45 45/50 50/55 55/60 60/65 65/70 70/75 30/35 35/40 40/45 45/50 50/55 55/60 60/65 65/70 70/75 30/35 35/40 40/45 45/50 50/55 55/60 60/65 65/70 70/75 30/35 35/40 40/45 45/50 50/55 55/60 60/65 60/70 70/75 30/35 35/40 40/45 45/50 50/55 55/60 60/65 65/70 70/75 30/35 35/40 40/45 45/50 50/55 55/60 60/65 65/70 70/75 93,8 90,2 87,5 83,3 79,7 75,8 72,5 69,1 65,9 119,1 115,5 110,2 106,3 100,6 95,9 90,7 85,2 80,0 135,0 131,5 126,9 123,0 118,8 114,0 109,1 103,4 99,0 161,4 156,5 152,1 147,1 141,7 136,1 129,6 123,7 117,4 196,1 188,7 181,1 174,5 167,2 159,9 151,7 143,9 136,6 230,1 224,4 215,6 207,7 199,9 190,9 181,0 170,9 162,0 266,4 258,9 251,5 241,7 232,6 223,8 213,9 204,4 194,9 24,4 25,4 26,3 27,1 27,8 28,5 29,1 29,7 30,4 30,5 31,8 32,8 33,8 34,6 35,3 35,8 36,2 36,5 30,83 32,5 34,0 35,4 36,9 38,1 39,4 40,4 41,7 39,36 41,5 43,5 45,4 47,1 48,7 50,1 51,5 52,8 47,65 50,1 52,2 54,3 56,2 57,9 59,3 60,7 61,9 58,25 61,4 63,9 66,3 68,3 70,1 71,5 72,7 73,7 67,1 70,8 74,3 77,3 80,3 83,0 85,4 87,8 90,1 3,8 3,6 3,3 3,1 2,9 2,7 2,5 2,3 2,2 3,9 3,6 3,4 3,1 2,9 2,7 2,5 2,4 2,2 4,4 4,0 3,7 3,5 3,2 3,0 2,8 2,6 2,4 4,1 3,8 3,5 3,2 3,0 2,8 2,6 2,4 2,2 4,1 3,8 3,5 3,2 3,0 2,8 2,6 2,4 2,2 4,0 3,7 3,4 3,1 2,9 2,7 2,5 2,4 2,2 4,0 3,7 3,4 3,1 2,9 2,7 2,5 2,3 2,2 105,4 101,8 98,1 94,1 90,3 86,3 82,9 78,9 74,6 135,0 129,7 124,2 120,1 114,5 108,9 103,2 97,7 92,0 151,3 147,0 142,7 137,4 133,3 127,8 122,6 117,1 111,4 181,0 175,8 170,3 165,0 159,8 153,1 146,6 139,7 133,1 218,2 211,2 203,7 195,4 187,0 179,4 171,2 162,6 153,5 259,5 251,7 245,6 235,1 226,4 216,0 206,0 195,4 184,1 302,0 294,4 283,5 272,6 263,6 252,9 242,6 232,4 221,6 25,13 26,3 27,4 28,4 29,4 30,3 31,2 32,0 32,5 31,55 33,0 34,3 35,6 36,6 37,5 38,3 38,9 39,4 32,07 34,0 35,9 37,5 39,2 40,7 42,2 43,7 45,1 40,52 43,1 45,4 47,6 49,8 51,7 53,6 55,3 57,0 49,42 52,3 55,0 57,4 59,6 61,6 63,5 65,2 66,7 60,44 63,8 67,1 69,7 72,2 74,4 76,3 78,0 79,3 70,32 74,5 78,2 81,7 85,3 88,7 91,7 94,7 97,4 4,2 3,9 3,6 3,3 3,1 2,9 2,7 2,5 2,3 4,3 3,9 3,6 3,4 3,1 2,9 2,7 2,5 2,3 4,7 4,3 4,0 3,7 3,4 3,1 2,9 2,7 2,5 4,5 4,1 3,8 3,5 3,2 3,0 2,7 2,5 2,3 4,4 4,0 3,7 3,4 3,1 2,9 2,7 2,5 2,3 4,3 3,9 3,7 3,4 3,1 2,9 2,7 2,5 2,3 4,3 4,0 3,6 3,3 3,1 2,9 2,6 2,5 2,3 114,7 110,8 106,6 102,1 98,1 93,9 90,0 85,7 81,7 145,6 141,0 135,7 130,2 124,3 117,9 112,5 106,6 101,2 163,7 158,4 153,3 148,8 143,6 137,8 132,1 126,2 120,7 196,0 191,7 185,1 178,6 172,3 165,4 158,9 151,5 144,7 236,5 228,0 219,8 211,2 203,3 194,5 185,1 175,9 169,0 281,2 272,6 263,4 255,2 245,2 234,9 223,8 214,3 201,9 329,4 318,3 306,5 296,7 285,8 275,4 264,2 253,4 241,5 25,61 26,9 28,2 29,3 30,5 31,5 32,5 33,4 34,3 32,21 33,9 35,4 36,7 38,0 39,0 39,9 40,8 41,5 32,97 35,0 37,1 39,0 40,8 42,5 44,2 45,9 47,5 41,3 44,2 46,8 49,3 51,6 53,9 56,1 57,9 60,0 50,78 53,9 56,8 59,6 62,1 64,5 66,5 68,5 70,7 61,85 65,5 68,9 72,0 74,9 77,4 79,7 81,8 83,3 72,34 76,7 80,8 85,0 89,0 92,7 96,2 99,8 102,9 4,5 4,1 3,8 3,5 3,2 3,0 2,8 2,6 2,4 4,5 4,2 3,8 3,5 3,3 3,0 2,8 2,6 2,4 5,0 4,5 4,1 3,8 3,5 3,2 3,0 2,7 2,5 4,7 4,3 4,0 3,6 3,3 3,1 2,8 2,6 2,4 4,7 4,2 3,9 3,5 3,3 3,0 2,8 2,6 2,4 4,5 4,2 3,8 3,5 3,3 3,0 2,8 2,6 2,4 4,6 4,1 3,8 3,5 3,2 3,0 2,7 2,5 2,3 124,2 119,9 115,1 110,7 106,1 101,5 97,3 92,3 87,9 158,5 152,8 146,9 141,2 134,9 128,6 122,2 115,7 109,1 175,9 170,7 166,2 161,2 154,0 148,5 142,3 136,6 130,4 212,7 206,5 200,2 193,3 186,8 179,2 172,1 164,0 156,8 260,1 251,3 242,1 232,7 222,7 212,4 202,6 193,1 182,3 305,0 297,5 286,0 275,9 265,7 253,6 240,7 231,4 218,6 361,4 347,3 335,3 322,4 311,4 299,3 286,8 274,8 262,3 26,06 27,6 29,0 30,3 31,5 32,7 33,9 34,9 35,9 32,9 34,7 36,4 38,0 39,4 40,5 41,6 42,6 43,3 33,75 36,1 38,4 40,6 42,5 44,5 46,4 48,3 50,0 42 45,2 48,1 50,9 53,7 56,1 58,6 60,7 63,1 52,3 55,9 59,2 62,3 65,1 67,7 70,1 72,3 74,2 63,29 67,4 70,9 74,4 77,6 80,4 82,8 85,4 87,1 74,47 79,3 84,1 88,6 92,9 97,0 100,9 104,9 108,2 4,8 4,3 4,0 3,7 3,4 3,1 2,9 2,6 2,4 4,8 4,4 4,0 3,7 3,4 3,2 2,9 2,7 2,5 5,2 4,7 4,3 4,0 3,6 3,3 3,1 2,8 2,6 5,1 4,6 4,2 3,8 3,5 3,2 2,9 2,7 2,5 5,0 4,5 4,1 3,7 3,4 3,1 2,9 2,7 2,5 4,8 4,4 4,0 3,7 3,4 3,2 2,9 2,7 2,5 4,9 4,4 4,0 3,6 3,4 3,1 2,8 2,6 2,4 129,2 124,5 119,7 114,8 109,8 104,9 100,4 95,2 89,6 164,8 158,5 153,1 146,4 139,9 133,3 126,8 119,7 113,1 183,9 178,0 172,6 167,0 160,7 154,5 147,9 141,1 134,4 221,2 215,0 208,3 201,1 194,1 185,9 177,7 169,5 162,0 269,9 260,4 250,7 241,5 231,3 221,2 209,8 199,1 188,2 318,7 308,5 297,6 287,7 276,3 264,3 251,8 238,5 226,4 377,8 363,9 351,5 338,5 325,0 313,1 300,0 286,2 273,3 26,28 27,9 29,4 30,8 32,1 33,3 34,4 35,4 36,2 33,21 35,1 36,9 38,5 40,0 41,3 42,5 43,4 44,2 34,21 36,7 39,0 41,3 43,5 45,5 47,5 49,3 51,2 42,33 45,7 48,8 51,7 54,6 57,2 59,7 62,1 64,3 52,97 56,7 60,2 63,4 66,4 69,2 71,5 73,8 75,9 64,07 68,2 72,1 75,6 78,9 81,9 84,6 86,9 88,8 75,44 80,6 85,7 90,5 95,2 99,4 103,6 107,4 111,1 4,9 4,5 4,1 3,7 3,4 3,2 2,9 2,7 2,5 5,0 4,5 4,1 3,8 3,5 3,2 3,0 2,8 2,6 5,4 4,9 4,4 4,0 3,7 3,4 3,1 2,9 2,6 5,2 4,7 4,3 3,9 3,6 3,3 3,0 2,7 2,5 5,1 4,6 4,2 3,8 3,5 3,2 2,9 2,7 2,5 5,0 4,5 4,1 3,8 3,5 3,2 3,0 2,7 2,5 5,0 4,5 4,1 3,7 3,4 3,1 2,9 2,7 2,5 135,9 130,3 124,6 118,4 112,5 106,5 100,9 95,3 89,7 174,5 167,3 161,5 153,9 147,1 138,2 130,2 122,0 113,6 194,5 188,4 182,0 175,3 169,0 162,1 154,1 144,9 137,6 234,2 226,7 219,9 211,7 201,9 192,2 182,4 172,5 162,6 285,7 275,4 264,4 254,5 243,1 230,7 217,3 204,4 190,7 337,7 326,5 314,4 303,3 290,5 275,2 259,4 243,9 228,3 402,1 388,5 374,3 360,1 344,9 331,4 316,4 299,0 282,2 26,55 28,2 29,7 31,1 32,4 33,3 34,5 35,4 36,2 33,65 35,7 37,6 39,3 40,9 42,0 42,9 43,8 44,3 34,84 37,4 40,0 42,4 44,6 46,8 48,7 50,3 51,9 42,73 46,3 49,7 52,8 55,6 58,1 60,3 62,6 64,5 53,92 57,9 61,5 65,0 68,1 70,8 73,0 74,9 76,5 65,03 69,4 73,5 77,2 80,7 83,5 85,5 87,4 89,2 76,87 82,6 88,0 93,3 98,1 102,6 106,9 110,3 113,1 To: Condenser in/out water temperature [°C] Ta: External air temperature (Dry Bulb) [°C] RH: relative humidity [%] kWF : cooling capacity [kW] (in conformity of EN14511) kWe: electrical power input in kW (in conformity of EN14511) The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. 5,1 4,6 4,2 3,8 3,5 3,2 2,9 2,7 2,5 5,2 4,7 4,3 3,9 3,6 3,3 3,0 2,8 2,6 5,6 5,0 4,5 4,1 3,8 3,5 3,2 2,9 2,6 5,5 4,9 4,4 4,0 3,6 3,3 3,0 2,8 2,5 5,3 4,8 4,3 3,9 3,6 3,3 3,0 2,7 2,5 5,2 4,7 4,3 3,9 3,6 3,3 3,0 2,8 2,6 5,2 4,7 4,3 3,9 3,5 3,2 3,0 2,7 2,5 Black HT 40 - 45 - 55 - 65 30 1408 1208 30 Pm Pm 2390 Rp Cdh Cdh Es Uout Rp 258 Rp 179 Rp 470 Rp Ep Lh Lh 333 333 Rout Uin A Uin B Rin A * Rin 252 C * 362 300 Technical book black ht 1500 1500 7 300 DIMENSIONAL DRAWING SPAZI DI INSTALLAZIONE \ CLEARANCES * SOLO PER VERIONE DWS ONLY DWS VERSION Ep QUADRO ELETTRICO ELECTRICAL PANEL Cdh SCARICO CONDENSA CONDENSATE DRAIN Es INGRESSO ALIMENTAZIONE ELETTRICA ELECTRICAL SUPPLY INLET Uin INGRESSO ACQUA UTILIZZO USER WATER INLET Lh FORI DI SOLLEVAMENTO LIFTING HOLES Uout USCITA ACQUA UTILIZZO USER WATER OUTLET Pm GRIGLIE DI PROTEZIONE PROTECTIVE METAL MESH Rin USCITA ACQUA RECUPERO RECOVERY WATER OUTLET Rp PANNELLO ASPORTABILE REMOVABLE PANEL Rout USCITA ACQUA RECUPERO RECOVERY WATER OUTLET \ \ \ Rev. Data-Date Dis.-Draftsman Denominazione-Denomination \ Visto-Checked by ø35 1"1/2 BSPM (A) 2" BSPM (B) 1"1/2 BSPM 1"1/2 BSPM (A) 2" BSPM (C) 1"1/2 BSPM Data-Date 05\09\2014 Sost. il dis.-Replace draw. / Materiale-Material / Spessore-Thickness / A B C ACQUA UTILIZZO\RECUPERO SENZA MODULO IDRAULICO USER\RECOVERY WATER WITHOUT HYDRAULIC MODULE ACQUA UTILIZZO CON MODULO IDRAULICO 1P-2P USER WATER WITH HYDRAULIC MODULE 1P-2P ACQUA RECUPERO CON MODULO IDRAULICO 1P RECOVERY WATER WITH HYDRAULIC MODULE 1P DIMENSIONI / DIMENSIONS LUNGHEZZA WIDTH PROFONDITA' DEPTH ALTEZZA HEIGHT 1408 1208 2390 \ Descrizione revisione-Revision description Codice-Code SCHEMA DIMENSIONALE / DIMENSIONAL DRAWING BLACK 35-45-50-55-60-65 Scala-Scale 1/30 CONNESSIONI IDRAULICHE / HYDRAULIC CONNECTION Dis.-Draftsman F. Sanavia Visto-Checked by N. Bettio Sost. dal dis.-Replaced by draw. / Trattamento-Treatment / / \ Disegno-Drawing SD00275 Rev. A Foglio di 1 N. 1 Sheet of Peso-Weight [kg] Colore vernice-Painted colour / - Proprietà riservata, riproduzione vietata a termini di legge.Copyright. - Reserved property, reproduction prohibited accordin to existent laws.Copyright. The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. 31 Black HT /OD 40 - 45 - 55 - 65 280 30 1408 1208 1688 30 Pm 2108 Pm Cdh Es Ep Uout Rp 258 Rp 179 Rp 470 Rp Lh Cdh 333 333 300 Lh Technical book Rout Uin A Uin B Rin A * Rin 252 C * 362 Black ht 1500 1500 7 2000 DIMENSIONAL DRAWING SPAZI DI INSTALLAZIONE \ CLEARANCES * 32 SOLO PER VERIONE DWS ONLY DWS VERSION Ep QUADRO ELETTRICO ELECTRICAL PANEL Cdh SCARICO CONDENSA CONDENSATE DRAIN Es INGRESSO ALIMENTAZIONE ELETTRICA ELECTRICAL SUPPLY INLET Uin INGRESSO ACQUA UTILIZZO USER WATER INLET Lh FORI DI SOLLEVAMENTO LIFTING HOLES Uout USCITA ACQUA UTILIZZO USER WATER OUTLET Pm GRIGLIE DI PROTEZIONE PROTECTIVE METAL MESH Rin USCITA ACQUA RECUPERO RECOVERY WATER OUTLET Rp PANNELLO ASPORTABILE REMOVABLE PANEL Rout USCITA ACQUA RECUPERO RECOVERY WATER OUTLET \ \ \ Rev. Data-Date Dis.-Draftsman Denominazione-Denomination \ Visto-Checked by ø35 1"1/2 BSPM (A) Data-Date 05\09\2014 Sost. il dis.-Replace draw. / Materiale-Material / Spessore-Thickness / A 2" BSPM (B) B 1"1/2 BSPM C ACQUA UTILIZZO\RECUPERO SENZA MODULO IDRAULICO USER\RECOVERY WATER WITHOUT HYDRAULIC MODULE ACQUA UTILIZZO CON MODULO IDRAULICO 1P-2P USER WATER WITH HYDRAULIC MODULE 1P-2P ACQUA RECUPERO CON MODULO IDRAULICO 1P RECOVERY WATER WITH HYDRAULIC MODULE 1P 1"1/2 BSPM (A) 2" BSPM (C) 1"1/2 BSPM DIMENSIONI / DIMENSIONS LUNGHEZZA WIDTH PROFONDITA' DEPTH ALTEZZA HEIGHT 1688 1208 2108 \ Descrizione revisione-Revision description Codice-Code SCHEMA DIMENSIONALE / DIMENSIONAL DRAWING BLACK OD 35-45-50-55-60-65 Scala-Scale 1/30 CONNESSIONI IDRAULICHE / HYDRAULIC CONNECTION Dis.-Draftsman F. Sanavia Visto-Checked by N. Bettio Sost. dal dis.-Replaced by draw. / Trattamento-Treatment / / \ Disegno-Drawing SD00276 Rev. A Foglio di 1 N. 1 Sheet of Peso-Weight [kg] Colore vernice-Painted colour / - Proprietà riservata, riproduzione vietata a termini di legge.Copyright. - Reserved property, reproduction prohibited accordin to existent laws.Copyright. The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. Black HT 75 - 90 - 70 - 85 - 105 - 125 26 1210 26 3510 Rp Ep Rp Es Rp 390 Rp 187 337 423 602 Rp Cdh Lh Lh Cdh * Lh Rout Rin Uout Uin * 1500 Rp 1000 1000 Technical book 1500 black ht SPAZI D' INSTALLAZIONE \ CLEARANCES 7 DIMENSIONAL DRAWING DIMENSIONI - DIMENSIONS LUNGHEZZA WIDTH PROFONDITA' DEPTH ALTEZZA HEIGHT 3510 1262 1912 Ep QUADRO ELETTRICO ELECTRICAL PANEL Cdh SCARICO CONDENSA CONDENSATE DRAIN ø 30 Es INGRESSO ALIMENTAZIONE ELETTRICA ELECTRICAL SUPPLY INLET Uin INGRESSO ACQUA UTILIZZO USER WATER INLET 2" 1/2 BSPF Uout USCITA ACQUA UTILIZZO USER WATER OUTLET 2" 1/2 BSPF PANNELLO ASPORTABILE REMOVABLE PANEL Rin INGRESSO ACQUA RECUPERO RECOVERY WATER INLET 2" 1/2 BSPF FLUSSO ARIA AIR FLOW Rout USCITA ACQUA RECUPERO RECOVERY WATER OUTLET 2" 1/2 BSPF Lh Rp FORI SOLLEVAMENTO LIFTING HOLES Ø40 33 SOLO PER VERSIONE DWS * ONLY DWS VERSION The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. Black HT 145 - 180 1210 4610 Rp Rp Es Rp 390 Rp 1916 A Cdh Cdh Lh Lh Cdh Lh * Rout Rin Uout * Uin 1500 Lh 187 337 423 604 1000 Ep 1000 Technical book 1500 Black ht SPAZI D' INSTALLAZIONE \ CLEARANCES 7 Rp Rp VIEW A DIMENSIONAL DRAWING 34 Ep QUADRO ELETTRICO ELECTRICAL PANEL Cdh SCARICO CONDENSA CONDENSATE DRAIN ø 30 Es INGRESSO ALIMENTAZIONE ELETTRICA ELECTRICAL SUPPLY INLET Uin INGRESSO ACQUA UTILIZZO USER WATER INLET 2" 1/2 BSPF Uout USCITA ACQUA UTILIZZO USER WATER OUTLET 2" 1/2 BSPF Lh Rp FORI SOLLEVAMENTO LIFTING HOLES PANNELLO ASPORTABILE REMOVABLE PANEL Ø40 FLUSSO ARIA AIR FLOW DIMENSIONI - DIMENSIONS LUNGHEZZA WIDTH 4610 PROFONDITA' DEPTH 1210 ALTEZZA HEIGHT 1916 The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. Black HT 200 - 235 5332 4888 1214 444 Ep Rp Lh Lh Lh Lh Rin Lh 523 Rp 192 Rp Uout Uin 188 850 168 194 Rout 390 2388 A 1500 Es 1000 2000 Rp Rp Technical book 1500 black ht SPAZI D 'INSTALLAZIONE \ CLEARANCES VIEW A 235 Ui n Uout Ri n Rout 3" BSPF 3" BSPF 3" BSPM 3" BSPM 7 DIMENSIONAL DRAWING CONNESSIONI IDRAULICHE \ HYDRAULIC CONNECTION DIMENSIONI / DIMENSIONS LUNGHEZZA WIDTH PROFONDITA' DEPTH ALTEZZA HEIGHT 5329 1211 2388 Ep QUADRO ELETTRICO ELECTRICAL PANEL Uin INGRESSO ACQUA UTENZA USER WATER INLET Es ALIEMNTAZIONE ELETTRICA ELECTRICAL SUPPLY Uout USCITA ACQUA UTENZA USER WATER OUTLET Lh FORI DI SOLLEVAMENTO LIFTING HOLES Rin INGRESSO ACQUA RECUPERO RECOVERY WATER INLET Rp PANNELLO REMOVIBILE REMOVABLE PANEL Rout USCITA ACQUA RECUPERO RECOVERY WATER OUTLET FLUSSO ARIA AIR FLOW The technical documentation can be improved all the times. Enerblue can update, time by time, all technical data in order to improve all necessary information for the customer. 35 032016_002 ENERBLUE S.r.l. Sede legale Via dell’Industria, 24 35028 PIOVE di SACCO - (Padova) Italy Sede operativa Via G. Puccini, 9 30010 CANTARANA di CONA - (Venezia) Italy Tel. +39.0426.302051 Fax +39.0426.840000 [email protected] www.enerblue.it
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement