for future reference.
ra Aquations range of flexible and rigid shower fittings are precision engi
a satisfactory shower over a range of pressures. They have been de
with, but are not restricted to, the Mira Aquations mixer valve.
DESCRIPTION
lowing shower fittings are covered by this guide:
quations Built-in Variable Shower Fittings (biv)
ustable spray handset with three different spray actions (start, force, s
economy setting*, supplied complete with right angle connector (RAC),
lide bar, adjustable handset holder and soap dish. Suitable for conne
aled supplies. The handset is supplied with a low capacity spray plate
gh capacity spray plate. Fittings are available in chrome and mixage fi
quations Built-in Flexible Shower Fittings (bif)
ustable spray handset with three different spray actions (start, force, s
economy setting*, supplied complete with right angle connector (RAC),
nd an adjustable parking socket. Suitable for connection to concealed su
ndset is supplied with a low capacity spray plate (fitted), and high c
plate. Fittings are available in chrome and mixage finishes.
conomy setting reduces the water flow to give economical use of water
ing an adequate shower performance. This setting performs best wit
pumped, and mains pressure unvented systems. On some combinatio
s the economy setting will have no effect, and will give the same spray
start setting.
quations Built-in Rigid Shower Fittings (bir)
spray head with three different spray actions (start, active and relax), s
nection to concealed pipework supplies only. The spray head is suppli
apacity spray plate (fitted), and high capacity spray plate. Fittings are av
me and mixage finishes.
quations Built-in Rigid Pin Clean Shower Fittings (bir Pin Clean)
ey are installed, commissioned, operated and maintained in accordan
e recommendations given in this Manual.
eriodic attention is given, as necessary, to maintain the product in
nctional order. Recommended guidelines are given in the MAINTEN
ction.
PACK CONTENTS
the appropriate boxes to familiarize yourself with the part names and to c
the parts are included.
Aquations biv Shower Fittings
2 x Wall Plugs
¨
¨
1 x Handset with Low
Capacity Spray Plate (small h
2 x End Supports
¨
1 x Slide Bar
1 x Clamp Bracket
¨
¨
1 x High Capacity
Spray Plate (large hole
¨
2x Wall Plugs
1 x 2.5 mm
Hexagonal Key
¨
¨
¨
2x Wall Screws
1 x Soap Dish
1 x Right Angled
Connector (RAC)
2 x Fixing Screws
¨
¨
¨
with Low Capacity Spray Pla
(small holes)
Hose Seals
¨
1 x Quad Key
exible Hose
¨
¨
1 x High Capacity
Spray Plate (large
¨
6x Fixing Screws ¨
6 x Wall Plugs
1 x 2.5 mm
Hexagonal K
Aquations bir Shower Fittings
mm
al Key
¨
2 x Fixing Screws
¨
2 x Wall Plugs
¨
1 x High Capacity
Spray Plate
(large holes)
¨
¨
1 x Spray Head with
Capacity Spray Plate (s
holes)
mm
al Key
2 x Fixing Screws
¨
2 x Wall Plugs
¨
¨
1 x Pin Clean High Capacity
Spray Unit (large holes)
¨
1 x Quad Key
mentation
allation, Operation and Maintenance Guide
stomer Support Brochure
¨
283 mm
max.
35 mm
600 mm
600 mm
70 mm
150 mm
Aquations bif Shower Fittings
Fit a minimum
of 300 mm
below ceiling
220 mm
302 mm
max.
ø 73 mm
58 mm
mm
83
SPECIFICATION
ortant Points:
e installation, commissioning and maintenance of this product must be
t in accordance with instructions given in this Manual, and must be con
designated, qualified and competent personnel.
e plumbing installation must comply with the requirements of UK
egulations/Bye-laws (Scotland), Building Regulations or any pa
gulations and practices, specified by the local water company or
dertakers. The installation should be carried out by a plumber or con
ho is registered, or is a member of, an association such as:
- Institute of Plumbing (IOP), throughout the UK.
- National Association of Plumbing, Heating and Mechanical S
Contractors (NAPH & MSC), England and Wales.
- Scottish and Northern Ireland Plumbing Employers’ Federation (SN
Scotland and Northern Ireland.
ra products are precision-engineered and should give continued super
fe performance, provided:-
-
they are installed, commissioned, operated and maintained in acco
with these recommendations.
-
periodic attention is given as necessary to maintain the product i
functional order. Recommended guidelines are given
my
Low Capacity
Spray Plate Fitted
High Capacity
Spray Plate Fitted
8.9 litres/minute
11.5 litres/minute
7.5 litres/minute
7.7 litres/minute
14.9 litres/minute
24.4 litres/minute
13.7 litres/minute
8.7 litres/minute
maintained inlet pressures at the shower control are above 1 bar fit th
y spray plate to the handset .
um maintained pressure: 5.0 bar.
ned pressures above this range could result in excessive spray forc
n possible damage to the product.
ir Fittings
pical flow rates for the bir handset at 0.5 bar pressure loss are:
Low Capacity
Spray Plate Fitted
9.4 litres/minute
9.9 litres/minute
15 litres/minute
High Capacity
Spray Plate Fitted
16.4 litres/minute
12.8 litres/minute
19.1 litres/minute
maintained inlet pressures at the shower control are above 1 bar fit th
y spray plate to the handset .
um maintained pressure: 5.0 bar.
ned pressures above this range could result in excessive spray forc
n possible damage to the product.
ir Pin Clean Fittings
pical flow rates for the bir handset at 0.5 bar pressure loss are:
Low Capacity
Spray Plate Fitted
15.7 litres/minute
High Capacity
Spray Plate Fitted
19.8 litres/minute
maintained inlet pressures at the shower control are above 1 bar fit th
iv, bif Shower Fittings
Mira Aquations biv, bif handset - low capacity spray plate fitted
.4
Economy
Force
2
.0
Start
Soothe
8
6
.4
2
0
0
2
4
6
8
10
12
Flow Rate (litres/minute)
14
16
18
Mira Aquations biv, bif handset - high capacity spray plate fitted
.4
Force
2
.0
Economy
8
Start
6
.4
Sooth
2
.2
Start
.0
Active
.8
.6
Relax
0.4
.2
0
0
2
4
6
8
10
12
Flow Rate (litres/minute)
14
16
18
Mira Aquations bir spray head - high capacity spray plate fitted
.4
.2
.0
Start
.8
Active
.6
Relax
0.4
.2
0
0
5
10
15
Flow Rate (litres/minute)
20
2
0
Low Capacity
8
6
4
High Capacity
2
0
0
5
10
15
Flow Rate (litres/minute)
20
pply pipework MUST be flushed to clear debris before connecting the
comply with water regulations the biv and bif shower fittings are s
th a check valve fitted to the right-angle connector (RAC). This
mbination with the checkvalves fitted to the Aquations shower control, p
cksiphonage and water contamination.
he biv or bif shower fittings are fitted to a shower control without check
sure that there is always a minimum gap of 25 mm between the hands
th/tray spill-over level.
th biv or bif shower fittings avoid layouts where the shower hose will be
nked as this may reduce the life of the hose.
o not fit any form of flow control in the outlet pipework if the shower f
stalled in conjunction with a product that requires the fitting to act as
g. an electric shower).
o not use excessive force when making connections.
o not install the product in a position where it could become frozen.
r a gravity fed shower installation, the minimum pressure at the showe
0.06 bar. To generate the minimum pressure and accommodate the pr
ss in the pipes and shower control, a head of water of 1.5 metre is requ
ypical correct installation.
r a Mira pump / Mira Aquations installation the minimum flow rate re
m the shower fitting is 1.2 litres/minute. (Equivalent to a head of w
proximately 0.6m (600mm)). This will ensure the pump flow switch will a
hen installing the shower fitting into a shower cubicle, it is best positio
ray across the cubicle rather than towards the cubicle opening.
yout and sizing of pipework should be such that when other servic
ed, pressures do not fall below the recommended minimum for that fit
s will cause the spray pattern to collapse.
uring installation handle fittings with care. Individual components are
d may damage surfaces if dropped from a height.
Angled Connector - Installation
ht angled connector assembly (RAC) should be positioned above and
side of the top outlet of the shower control. This will prevent the flexib
bstructing the shower control temperature and flow control knobs.
pework between the shower control and the RAC is not supplied as par
r fitting.
ecide where the RAC will be
sitioned. Chisel out a channel in the
all for the pipework.
the outlet pipework in the channel
d connect to the shower control.
sure that the pipe extends far enough
m the wall that, with the finished wall
rface applied, the pipe protrudes at
ast 15mm from the wall.
pply the finishing coat of plaster and
es to the wall.
Outlet Pipe
Hot Inlet
Cold
Shower
15 mm
heck that the pipe extends 15mm from
e wall surface. If necessary cut the
pe to length and remove any burrs.
ndo the grub screw securing the
ckplate to the RAC body with the
xagonal key provided. Remove the
ckplate from the RAC assembly.
ndo the compression nut and olive,
king care not to damage the 'O' seal
the compression nut.
de the backplate onto the outlet pipe
d mark the position of the fixing holes.
Ensure none of the fixing holes are
oned directly over the connecting
Finis
Surfa
Ensure the backplate is fitted so the
screw holes are not in line with any
pipework
W
an
S
heck the ‘O’ seal is fitted to the
mpression nut.
Pipe
R
de the olive and compression nut
er the outlet pipe and tighten
fficiently to make the compression
nt. Take care not to damage the 'O'
al on the compression nut.
Backplate
Ensure 'O' Seal
is Fitted
Grub
Screw
and secure the RAC body to the
ckplate.
Angled Connector - Fitting Flow Regulator
maintained inlet water pressure is high the shower spray force may pro
ce to shower under. Fitting the flow regulator (supplied) will limit the
um flow rate to 10 L/Min, and reduce the spray force to a more comfo
The regulator may also be fitted if water conservation is a concern.
nscrew the outlet connector from
e RAC with a 12 mm A/F wrench
ot supplied).
RAC Body
the flow regulator as illustrated.
sure the ‘O’ seals are fitted and
e flow regulator is placed the
rrect way up.
efit the outlet connector to the RAC.
Dire
Wat
Flow Regulator
‘O’ Seal
‘O’ Seal
e slide bar at 600 mm centres,
oiding any buried cables or pipes,
d insert the wall plugs.
ssemble the clamp bracket
mponents. Push the plastic slide
r ends into the slide bar.
600mm
sh the slide bar through the clamp
acket assembly.
the bottom end support loosely to
e wall. This will make aligning the
p support easier. Insert the fixing
rew into the countersunk hole of
e plastic slide bar end and through
e slide bar support.
Clamp
Bracket
Assembly
S
ace the screw through the top end
pport and fully tighten. Fully tighten
e bottom end support.
the end support caps over the
ds of the slide bar end supports.
End S
Cap
rew the hose onto the handset and
to the outlet of the shower control
ake sure the hose seals are fitted).
o not overtighten.
ace the handset into the slide bar clamp bracket.
The clamp bracket is tapered. The handset will only fit properly from o
on. If necessary turn the end of the clamp bracket until the handset wi
amp bracket pivots downwards under the weight of the handset the c
g screw in the bracket will require tightening in order to hold the hand
n.
ark the position of the fixing holes.
19 mm
ill the two 6.0 mm fixing holes for
e soap dish at 19 mm centres,
oiding any buried cables or pipes,
d insert the wall plugs.
the backplate to the wall with the
xt "TOP" at the top of the backplate.
the ring on to the soap dish and
sh the soap dish into the backplate
til its snaps into position.
Ring
Backplate
Soap Dish
pework between the shower control and the RAC is not supplied as par
r fitting.
ng Socket - Installation
arking socket should be fixed to the wall to one side of the produc
nient height for all the family. It should be positioned so that it disc
he centre line of the bath, or across the opening of a shower cubic
be directed away from the shower
.
ecide where the parking socket will
positioned. The parking socket
Wall Plugs and
ust be positioned at least 300mm
Fixing Screws
low the ceiling. This will allow the
Grub
ndset to be easily placed in and
Scre
moved from the parking socket.
ndo the grub screw with the
xagonal key provided, and pull the
ckplate away from the parking
cket body.
Backplate
ace the backplate on the wall and
ark the position of the fixing holes.
e bracket will need to be fitted with
e word 'TOP' positioned at the
ttom of the bracket.
Parking Socket
Body
ote! Ensure none of the fixing holes are positioned over pipew
ectrical cables.
ill the 6.0 mm fixing holes and insert the wall plugs provided.
the backplate to the wall.
the parking socket to the backplate and secure with the grub screw.
the hose washers to the hose, then attach the hose to the handset. Pla
ndset in the parking socket, and fit the hose to the RAC or shower co
ng Socket - Adjustment
pplied) in the hexagonal slot at the
ck of the parking socket body. Turn
e key clockwise to increase or
ticlockwise to decrease the swivel
ffness.
nce the adjustments are complete
it the parking socket body to the
ckplate and resecure.
Quad Key
RAC Body
Aquations bir and bir Pin Clean Fittings
y Head - Installation
and bir Pin Clean should be positioned at a convenient height for all the
d be positioned so that it discharges down the centre line of the bath, or
ening of the shower cubicle and should be directed away from the s
.
pework between the shower control and the spray head is not supplied
shower fitting.
nsure the outlet pipe extends
ø 15 mm
tween 15 mm and 40 mm from the
ished wall surface. If the pipe
otrudes less than 15mm it will not
possible to fit the spray head. If the
pe extends further than 40mm then
t to length and remove any burrs.
ndo the grub screw with the
xagonal key provided, and remove
e backplate from the spray head.
ndo the compression nut and olive.
ø 6 mm
37 mm
Grub Screw
Backplate
ø
ng screws and wall plugs provided.
Pipe
Fixin
Scre
de the olive and compression nut
er the outlet pipe and tighten
fficiently to make the compression
nt.
Ensure the
'O' Seal is
Fitted
emoved ensure the ‘O’ seal is refitted onto the backplate.
the spray head to the backplate and secure with the grub screw.
y Head - Fitting Flow Regulator
tallations where the force of the spray from the spray head is exces
water conservancy is an issue, the 9 litre/minute flow regulator supplied
d to the spray head.
emove the spray unit. Refer to Spray
nit - Removal and Installation in
AINTENANCE.
Spray Head B
se a 12 mm A/F Hexagonal Wrench
ot supplied) or the quad key to
screw and remove the strainer / flow
gulator assembly from the shower
ing.
Internal
Strainer
emove the internal strainer from the
using.
the 9 Litres/Minute flow regulator
pplied into the housing and refit the
ainer. The regulator must be fitted
illustrated.
efit the complete assembly into the
ower body.
Flow Regu
Direction of
Water Flow
Housin
Q
ra Aquations biv, bif adjustable handset has three different spray actions
and force) and an economy setting.
Spray
Start
e adjuster ring until the three dots
th top centre of the handset. Water
w from the outer set of holes.
he Spray
Soothe
he adjuster ring until the two dots
ith top centre of the handset. Water
w from the middle set of holes.
e Spray
Force
e adjuster ring fully anticlockwise.
ngle dot will align with top centre of
ndset. Water will flow from the inner
holes.
omy Spray Setting
e adjuster ring fully clockwise. The
mbol will align with top centre of the
et. Water will flow from the outer set
s and the flow rate will be reduced.
Economy Setting
Spray
e adjuster fully clockwise to divert
ter into the outer holes.
e Spray
he adjuster fully anticlockwise to
he water into the inner holes.
x Spray
ng a “mid” position allows the water
from both sets of holes, giving a
flow rate at a lower pressure.
n Clean Shower Fittings
r Pin Clean spray head has a fixed spray pattern with a limescale c
.
hen water begins to flow from the
ray head the water pressure pushes
e spray plate forward, sealing it
ainst the spray plate retainer. The
l spray pattern forms and showering
n commence.
hen the flow of water stops the spray
ate automatically retracts to the rest
sition, and any residual water will
ain away.
essing the spray plate causes a
ance with the instructions contained in this guide, difficulties should no
maintenance is required then it must be carried out by a competent trades
om the fault diagnosis chart and maintenance instructions are provided.
ng any parts ensure that the underlying cause of the malfunction ha
ed.
alfunction
w or low flow rate.
rom spray plate
bly in handset or bir
bly.
er temperature
es when spray
s adjusted.
r handset will not
any position.
Cause
Remedy
Spray plate assembly (biv, bif fittings)
or internal strainer (bir, bir Pin Clean
fittings) blocked.
Clear blockage, refer
relevant cleaning proced
MAINTENANCE.
Hose blocked or twisted. (biv, bif fittings
only).
Clear blockage or releas
in hose.
A small amount of water may be retained
in the shower fitting after the shower
control has been turned off. This may
drain over a few minutes.
This is quite normal. For
and the bif fittings chang
angle of the handset ma
the draining time.
Defective seal(s) in the shower control.
Refer to shower c
Installation, Operatio
Maintenance Guide.
Spray plate assembly blocked.
Clear blockage, refer
relevant cleaning proce
MAINTENANCE.
Adjusting the spray action changes
the flow of water. This may affect
some shower controls and plumbing
installations.
Install the high capacit
plate assembly, refer
relevant removal and ins
procedures in MAINTEN
If the malfunction persis
to the shower control Inst
Operation and Maint
Guide for details on the
control or plumbing inst
The clamp bracket (biv fittings) has a
Tighten the securing
used for cleaning plated or plastic fittings. These finishes should be c
mild washing up detergent or soap solution, and then wiped dry using
bif Shower Fittings
y Plate - Removal
rn the adjuster
ticlockwise.
ring
fully
Hand
Asse
nclip and remove the adjuster ring.
Sp
As
nscrew the spray plate in an antiockwise direction. The 'O' seals will
ovide some resistance.
Adjus
y Plate - Installation
'O' Se
ake sure that the four 'O' seals are
cated correctly.
Flow
Spray
Assem
rn the flow divertor fully clockwise.
aution! Do not over tighten the spray
ate.
arefully screw the spray plate
sembly on to the flow divertor. The
seals will resist the rotation of the
ray plate. There should be a gap
tween the edge of the spray plate
sembly and the flow divertor.
ake sure that the green bar on the
juster ring is uppermost and align
e inner teeth on the adjuster ring with
'O
'O' Seal
'O' Seal
Teeth
Spr
Ass
ate assembly.
y Plate - Internal Cleaning
emove the spray plate assembly.
efer to Spray Plate - Removal.
emove the 'O' seals.
'O' S
ean all the components with a stiff
ush. If necessary use a plastic kettle
scalent in accordance with the
anufacturer's instructions.
efit the components in reverse order.
stall the spray plate assembly. Refer
Spray Plate - Installation.
Spray Pl
ed or replaced. Turn the adjuster
nticlockwise, grip the body and
w the complete adjustable spray
m the spray head. Leave the inner
l in the spray head body.
Bo
g is the reverse of removal.
Spray Plate
Spray Plate Key
y Plate - Removal and Cleaning
rn the adjuster fully anticlockwise
d grip the spray unit, engage the
ray plate key in the spray plate, turn
ticlockwise to remove the spray
ate and divertor seat. Leave the 'O'
al in place on the spray unit.
her clean with a stiff brush or dip
o proprietary plastic kettle descalent
cording to the descalent
anufacturer’s instructions.
o not use metal probes to clear
ray holes, as this will damage the
ray plate and degrade the spray
ttern.
sure the 'O' seal is in place on the
ray unit and refit the divertor seat.
e divertor seat is should be fitted
illustrated.
rew the spray plate clockwise into
'O' Seal
Divertor Seat
P
n of
ow
2.
Use a 12 mm A/F hexagonal w
(not supplied) or the quad
unscrew and remove the str
flow regulator assembly fro
shower fitting.
3.
Remove the internal strainer a
flow regulator from the hous
necessary clean the strain
flushing through under a jet o
to remove lodged particles. D
descale.
4.
Fit the internal strainer and th
regulator into the housing
regulator must be fitted as illus
Fit the complete assembly in
spray head body.
5.
Install the spray unit. Refer to
Unit - Removal and Installat
Internal
Strainer
Flow Regulator
Housing
Quad Key
me.
nscrew the spray plate retainer
ticlockwise and remove.
emove the spray unit, leave the inner
seal in the spray head.
Inner O Seal
Spray Unit
Spray Plate
Retainer
efit the spray unit.
crew the spray plate retainer
ockwise onto the spray head.
Retainer
ap the retainer trim in place.
Spray Unit - Removal and Instal
y Unit - Cleaning
emove the spray unit. Refer to Spray Unit - Removal and Installatio
her clean with a stiff brush or dip into a proprietary plastic kettle de
cording to the descalent manufacturer’s instructions.
o not use metal probes to clear the spray holes, as this will damage the
ate and degrade the spray pattern.
stall the spray unit. Refer to Spray Unit - Removal and Installation.
ner/Flow Regulator Assembly - Removal and Cleaning
emove the spray unit. Refer to Spray Unit - Removal and Installatio
se a 12 mm A/F hexagonal wrench (not supplied) or the quad key to u
d remove the strainer / flow regulator assembly from the spray head.
emove the internal strainer and the flow regulator from the housing. If nec
ean the strainer by flushing through under a jet of water to remove
rticles. Do not descale.
Internal
Strainer
Direction of
Water Flow
Flow Regulator
Housing
Quad
Key
Strainer/Flow Regulator Assembly - Removal and Cleaning
Slide Bar Ends
Service Pack 'O' Seals - components identified 'A'
Adjuster Ring - satin chrome
Handset Body Assembly - chrome
Spray Plate Assembly - High capacity - dark grey
Spray Plate Assembly - Low capacity - dark grey
RAC Backplate Assembly
Flow/Checkvalve Nipple
RAC Assembly - chrome
RAC Assembly - mixage
Complete Slide Bar Arm Assembly
Slide Bar
Slide Bar Wall Fixing Assembly
Hose
Soap Dish - chrome
Soap Dish - mixage
Hose Seal x2
A
413.60
413.61
449.02
632.73
4
449.05
449.09
441.69
441.73
7
126.65
441.68
449.08
449.11
Handset Body Assembly - chrome
Spray Plate Assembly - High capacity - dark grey
Spray Plate Assembly - Low capacity - dark grey
Hose - chrome
Parking Socket Backplate Assembly
RAC Backplate Assembly
Flow/Checkvalve Nipple Assembly
RAC Assembly - chrome
Parking Socket Adjuster Assembly
Parking Socket Body Assembly - chrome
Parking Socket Body Assembly - mixage
RAC Assembly - mixage
Hose Seal x2
4
441.36
A
441.70
441.71
441.72
441.69
441.73
441.67
410.69
441.68
413.60
413.61
413.22
Low Capacity Spray Plate
Compression Backplate Assembly
Strainer/Flow Regulator Assembly
857.33
441.66
441.60
441.61
Pin Clean Spray Unit - Low Capacity
Pin Clean Spray Unit - High Capacity
Strainer/Flow Regulator Assembly
857.33
441.78
441.79
441.66
441.77
130.83
Clean fittings (A soap dish is included in the pack contents of the Aquati
. It is available in chrome and mixage finishes.
449.08
449.11
Soap Dish - chrome
Soap Dish - mixage
Uploaded on http://www.qssupplies.co.uk
- Document BY MIRA
he guarantee, please return your completed
card.
arantee period we will resolve defects, free of
airing or replacing parts or modules as we may
charge, service work must only be undertaken
ers or our approved agents in Northern Ireland
of Ireland.
er this guarantee does not affect the expiry
arantee on any exchanged parts or product
e normal product guarantee period expires.
Spare Parts
We maintain an extensive stock of spares, and
have functional parts available for ten years from th
of final manufacture of the product.
Spares can be purchased from approved stock
merchants (locations on request) or direct from Cus
Services.
Spares direct will normally be despatched with
working days. Payment can be made by credit card
time of ordering. Should payment by cheque be pre
a pro-forma invoice will be sent.
Note! In the interests of safety, spares requiring exp
to mains voltages can only be sent to competent pe
by this guarantee:
Service
defects arising from incorrect installation,
or lack of maintenance, including build-up of
Our Service Force is available to provide a quality
a reasonable cost. You will have the assurance
trained engineer/agent, genuine Mira spares –
month guarantee on the repair.
efects if the product is taken apart, repaired or
ny person not authorised by Mira Showers or
agents.
ee is in addition to your statutory and other
ing your shower
e time to read and understand the operating
structions detailed in this manual.
o if something goes wrong
st use your shower it doesn’t function correctly,
your installer to check that installation and
g are satisfactory and in accordance with the
this manual. We are on-hand to offer you or
any advice you may need.
ot resolve the difficulty, simply contact our
rvices who will give every assistance, and if
ange for our service engineer to visit.
ormance of your shower declines, consult this
whether simple home maintenance is required.
r Customer Services to talk the difficulty through,
ce under guarantee if applicable, or take
our comprehensive After-Sales service.
r quality and training programme calls
rded or monitored.
Payment should be made directly to the Service
Agent, using credit card or a cheque supported by
card.
To contact us:
England, Scotland & Wales
Mira Showers Customer Services
Telephone:
0870 241 0888
8.30am to 5pm Working days (4.30pm Fri)
8.30 am to 12.30pm Saturday
E-mail: Mira_technical@mirashowers.com
Fax:
01242 282595
By Post:
Cromwell Road
Cheltenham
Gloucester GL52 5EP
For Customers in Northern Ireland
Wm H Leech & Son Ltd
Telephone:
028 9044 9257 – Mon to Fri 9
Fax:
028 9044 9234 – 24 hours
Post:
Maryland Industrial Estate
Ballygowan Road
Moneyreagh, Co Down
BT23 6BL
For Customers in Republic of Ireland
Modern Plant Ltd
Telephone: Dublin 01 4591344 - Mon to Fri 9am
Fax:
Dublin 01 4592329 – 24 hours
Post:
Otter House
Naas Road
Clondalkin