SPECIFICATIONS
Model
FES-4548-3
Part Number
08722202
kW
45
Volts
480
PH
3
Amps
55.5
Fan Output
2200 CFM
Heat Output
154,000 BTU
Dim A
Description - Fostoria portable electric salamander heaters provide clean, odor-free, fan-forced
heat. They are designed to circulate room air continously; gradually heating a confined space. The
best results will be obtained when using these heaters in smaller, insulated spaces. Features include
a safety-yellow enclosure with front and rear safety screens; reliable steel finned heating elements; a
high-limit temperature switch with manual reset; an automatic thermostat control; fan switch; and a
long-life motor and fan assembly with sealed bearings. The portable (FES) models come mounted on
a three-wheeled cart with wheels designed to be easily pushed or pulled over uneven surfaces.
FORM: 8992
ECO 1-5863
WIRING
THE PROPER SIZE SO- type feeder cable MUST BE USED for the electrical hook-up of this heater. The proper cable size
is shown in the table below (A.W.G./ # of conductors.)
Model
FES - 4548 - 3
Unit Rating
Cable Size - Under
50ft. long
45kW, 480 Volt, 3-Ph
4/4
Cable
Kit Number
xxxxxx
•
Disconnect from electrical supply before installing feeder cable to these heaters.
•
Feeder cable or cable kit assembly MUST BE made by licensed electricians ONLY.
•
Service panel or receptacle used to supply power to these heaters MUST have a ground bus or
ground pole that is securely bonded to earth ground.
•
Connect green ground conductor on feeder cable or cable kit to grounding lug on heaters.
•
Comply with ALL local electrical codes and the National Electric Code (NFPA70) when providing
electrical power to these heaters.
FAN
3
1
HEAT
H
H
FAN
DELAY
OFF
BTB
FORM: 8992
ECO 1-5863
OPERATING INSTRUCTIONS
The FES series heaters are designed to circulate room air across its heating elements to gradually
increase room temperature. The best performance results will be obtained when using these heaters
in smaller, confined spaces with low ceilings.
Operation of these heaters is accomplished using the thermostat and fan switch.
You have the option to use the fan only*, or the fan and heating elements together. Position the fan
switch to the “fan” position to circulate room air with no heating. Move the switch into the “heat” position
for control of fan and elements with the thermostat. Maximum heating is obtained with knob
turned fully clockwise**.
This heater is equipped with an automatic fan purge that eliminates residual heat after the
heating cycle . Allow the heater to full purge before disconnecting power to the heater. This will
eliminate the possibility of cycling the heater on the limit control.
*The thermostat has a preset range of 40oF, there will be no “fan only” function as the
thermostat is always calling for heat.
**Setting the thermostat to high heat versus low heat does not make the unit operate at a
higher temperature. It simply raises the temperature necessary to satisfy the thermostat.
The unit will run longer to try to satisfy a higher thermostat setting.
Note: ALL FES models are equipped with an internal over temperature limit designed to protect your
heater if a restricted airflow condition occurs. This limit device will completely shutdown the heating
elements if the temperature limit is reached. The limit must be manually reset when the unit cools.
The reset button is marked and located on the side of the control box near the thermostat knob.
WARNING:
‹
‹
‹
‹
‹
‹
‹
‹
Do not use outdoors or where flammable gases or liquids are stored.
Do not use as a residential comfort heater.
Keep portable heater 3ft. minimum from all combustible materials at all times.
Do not modify heater in any way.
Do not provide power to heater when unit is near standing water.
Only use handle to move heater.
Do not touch heater housing when in use.
Do not allow feeder cable to contact combustible materials.
FORM: 8992