EN
INSTALLATION, OPERATION AND
MAINTENANCE INSTRUCTIONS,
for the User and the Installer
FR
NL
ES
Comfort E
IT
100 - 130 - 160 - 210 - 240
DE
PL
RU
A1002860 - 661Y1600 • D
EN
TABLE OF CONTENTS
GENERAL RECOMMENDATIONS................................................................4
FR
PRODUCT INFORMATION.........................................................................5
Energy labelling........................................................................................................................................................ 5
Rating Plate.................................................................................................................................................................. 6
NL
USER'S GUIDE...............................................................................................7
Control Panel............................................................................................................................................................... 7
ES
APPLIANCE DESCRIPTION..........................................................................8
Models - Comfort E 100 - 130 - 160 - 210 - 240................................................................................................. 8
IT
TECHNICAL CHARACTERISTICS..............................................................10
Dimensions and main Characteristics..................................................................................................10
Electrical Characteristics..................................................................................................................................12
Performance..............................................................................................................................................................13
DE
INSTALLATION..........................................................................................14
Safety Instructions................................................................................................................................................14
PL
Packing Contents...................................................................................................................................................16
Tools.................................................................................................................................................................................16
Tank Position.............................................................................................................................................................17
Connection.................................................................................................................................................................18
RU
Comfort E tank used as electric DHW tank only..........................................................................20
Available Kits and Accessories....................................................................................................................20
en
2
Comfort E : A1002860 - 661Y1600 • D
TABLE OF CONTENTS
EN
STARTING UP.............................................................................................21
FR
Safety Instructions to Fill the Tank...........................................................................................................21
Filling...............................................................................................................................................................................22
Checks before Starting up..............................................................................................................................24
NL
Starting Up Procedure.......................................................................................................................................24
MAINTENANCE.........................................................................................25
Periodic Checks by the User.........................................................................................................................25
ES
Annual Maintenance..........................................................................................................................................25
Draining.........................................................................................................................................................................26
Bringing back into Service after Maintenance..............................................................................26
Replacement of the Electric Heating Element..............................................................................28
IT
Fault Finding..............................................................................................................................................................29
DE
PL
RU
en
Comfort E : A1002860 - 661Y1600 • D
3
EN
GENERAL RECOMMENDATIONS
NOTES
This manual contains important information with respect to the installation, the starting up and
the maintenance of the appliance.
FR
This manual must be provided to the user, who will read it carefully and keep it in a safe place.
We accept no liability should any damage result from the failure to comply with the instructions contained in this technical manual.
NL
Essential recommendations for safety
ES
IT
DE
•
It is strictly prohibited to carry out any modifications to the appliance without the
manufacturer’s prior and written agreement.
•
The product must be installed by a qualified engineer, in accordance with
applicable local standards and regulations.
•
The installation must comply with the instructions contained in this manual and
with the standards and regulations applicable to domestic hot water tanks.
•
Failure to comply with the instructions in this manual could result in personal
injury or a risk of environmental pollution.
•
The manufacturer declines all liability for any damage caused as a result of
incorrect installation or in the event of the use of appliances or accessories that are
not specified by the manufacturer.
Essential recommendations for the correct operation of the appliance
PL
•
In order to ensure that the appliance operates correctly, it is essential to have it
serviced by a certified installer or maintenance contractor every year.
•
In case of anomaly, please call your installer for advice.
•
Faulty parts may only be replaced by genuine parts.
•
Our water heaters are designed and manufactured for the exclusive purpose of
heating and storing domestic hot water.
The domestic hot water heaters must only be heated using hot water in a closed
circuit.
•
RU
General remarks
•
The availability of certain models as well as their accessories may vary according to
markets.
•
The manufacturer reserves the right to change the technical characteristics and
features of its products without prior notice.
The part number (P/N) and serial number (S/N) of the appliance are indicated on its
rating plate and must be provided to ACV in case of warranty claim. Failure to do
so will make the claim void.
•
•
In spite of the strict quality standards that ACV applies to its appliances during
production, inspection and transport, faults may occur. Please immediately notify
your approved installer of any faults.
en
4
Comfort E : A1002860 - 661Y1600 • D
EN
PRODUCT INFORMATION
ENERGY LABELLING
FR
NL
ES
IT
DE
PL
RU
en
Comfort E : A1002860 - 661Y1600 • D
5
EN
PRODUCT INFORMATION
RATING PLATE
FR
NL
ES
IT
DE
PL
RU
en
6
Comfort E : A1002860 - 661Y1600 • D
USER'S GUIDE
EN
CONTROL PANEL
4
FR
NL
ES
IT
1
2
3
Heating
element ON
Heating
element OFF
DE
PL
RU
Key :
1. Control thermostat [60/80°C] - To set the domestic hot water (DHW) temperature.
2. Fuse FF 12,5 Amp - To provide an electric protection to the appliance.
3. Summer / Winter switch - To activate the heating pump of the installation/deactivate the
electrical heating element ( - winter position) or activate the electrical heating element/
deactivate the installation pump ( - summer position).
4. Heating-element-on indicator - The built-in indicator lights when the heating element is
activated ( position of the summer / winter switch).
en
Comfort E : A1002860 - 661Y1600 • D
7
EN
APPLIANCE DESCRIPTION
MODELS - Comfort E 100 - 130 - 160 - 210 - 240
Storage water tanks, to be installed vertically on the wall, that can work within a heating installation, or independently as electric domestic hot water heater only. The Comfort E tank is equipped
with one 2200 W heating element controlled by the thermostat and by the Summer/Winter switch
on the appliance control panel.
FR
Key
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
NL
ES
IT
Cold water inlet
Domestic hot water outlet
Manual air bleed valve
Primary fluid inlet
Primary fluid outlet
30 mm of insulation in polyurethane (without CFCs)
Primary carbon steel tank
DHW stainless steel tank
Rigid polypropylene cover
External polypropylene casing
Stainless steel dry-well
Electric heating element 2200 W
Control panel
DE
PL
RU
en
8
Comfort E : A1002860 - 661Y1600 • D
APPLIANCE DESCRIPTION
EN
3
FR
9
NL
4
7
ES
10
2
IT
6
DE
11
8
PL
12
5
RU
9
1
13
en
Comfort E : A1002860 - 661Y1600 • D
9
EN
TECHNICAL CHARACTERISTICS
DIMENSIONS AND MAIN CHARACTERISTICS
FR
Comfort E
Tank dimensions
NL
100
130
160
210
240
A
mm
845
1005
1205
1480
1725
B
mm
365
525
725
1000
1245
C
mm
630
790
990
1260
1510
Empty weight
Kg
37
40
47
58
65
ES
Comfort E
Main characteristics
IT
DE
160
210
240
L
105
130
161
203
242
Primary capacity
L
30
55
62
77
78
DHW capacity
L
75
75
99
126
164
Primary connection [F]
"
1
1
1
1
1
DHW connection [M]
"
3/4
3/4
3/4
3/4
3/4
mbar
19.6
22.4
23.5
40.6
46.5
Heating surface area
m²
1.03
1.03
1.26
1.54
1.94
Max Design Pressure*
bar
10
10
10
10
10
Reheat Performance - Primary Heating Power Input*
kW
18.4
18.4
24.7
32.2
39.2
Primary flow rate (to achieve Reheat
Performance) *
L/sec.
0.7
0.7
0.7
1.25
1.25
min
10
10
10
9
9
kWh/24h
1.39
1.54
1.7
1.85
1.94
W
58
64
71
77
81
Reheat time*
RU
130
Total capacity
Primary pressure drop*
PL
100
Standing Heat Loss*
* According to EN12897:2006
en
10
Comfort E : A1002860 - 661Y1600 • D
TECHNICAL CHARACTERISTICS
EN
FR
530
NL
B
A
ES
IT
265
265
DE
325
563
PL
298
RU
C
360
en
Comfort E : A1002860 - 661Y1600 • D
11
EN
TECHNICAL CHARACTERISTICS
ELECTRICAL CHARACTERISTICS
FR
Comfort E
Main characteristics
Rated voltage
V~
100
230
130
230
160
230
210
230
240
230
Rated frequency
Hz
50
50
50
50
50
W
2,200
2,200
2,200
2,200
2,200
A
10
10
10
10
10
Electrical consumption with
electrical heating element
Rated current with electrical
heating element
NL
Wiring diagram
ES
IT
1.
2.
3.
4.
5.
6.
7.
8.
230 Volt connection cord
Control thermostat [60/80°C]
Manual reset high limit thermostat [89°C max.]
Summer / Winter switch
Fuse FF 12,5 A
Electric heating element
Load pump [in option]
Heating-element-on indicator
DE
B
3
t
Bk
Or
B
PL
2
t
Y/Gr
c
2
T1
Gr
1
Br
6
Bk
5
M
7
RU
Bk
B
8
B
T2
B
4
W
B
Br
Y/Gr
B
1
L1
PE
N
230 V ~50Hz
B
Y/Gr
Br
en
12
Comfort E : A1002860 - 661Y1600 • D
B.Blue
Bk.Black
Br.Brown
G.Grey
Or.Orange
W.White
Y/Gr.Yellow/Green
TECHNICAL CHARACTERISTICS
EN
PERFORMANCE
Comfort E
DHW performance
Peak flow at 45 °C *
L/10'
FR
100
130
160
210
240
182
202
275
348
469
Peak flow at 45 °C *
L/60'
604
672
911
1156
1560
Constant flow at 45 °C *
L/h
507
564
763
970
1309
Power drawn *
kW
23
23
31
39
53
2 h 43'
3 h 27'
4 h 20'
5 h 37'
6 h 37'
Heating time with the 2.2 kW
heating element, from 10 to 60°C
NL
ES
* Primary temperature : 85°C , water supply temperature : 10°C
IT
DE
PL
Comfort E
Maximum Operating Conditions
100
130
160
210
240
Max. operating pressure - primary
bar
3
3
3
3
3
Max. operating pressure - DHW
bar
8.6
8.6
8.6
8.6
8.6
Supply pressure (DHW circuit)
bar
6
6
6
6
6
Maximum temperature - heating side
°C
90
90
90
90
90
Maximum temperature - DHW side
°C
80
80
80
80
80
Water quality
•
•
•
RU
Chlorides < 150 mg/L
6 ≤ pH ≤ 8
If hardness > 20°fH, water softener recommended.
en
Comfort E : A1002860 - 661Y1600 • D
13
EN
INSTALLATION
SAFETY INSTRUCTIONS
FR
General remarks
NL
•
Connections (electrical, hydraulic) must be carried out in accordance with
applicable standards and regulations.
•
If the water drawing off point is far from the tank, installing an auxiliary DHW loop
can allow to get hot water more quickly at all times.
Essential instructions for the correct operation of the system
ES
IT
•
The tank must be installed in a dry and protected area.
•
Install the appliance to ensure easy access at all times.
•
To avoid any risk of corrosion, connect the stainless steel tank directly to the earth.
•
Make sure to install a pressure reducing valve set at 4.5 bar in the DHW circuit if the
supply pressure is higher than 6 bar.
•
On the DHW circuit, install an approved safety group, comprised of a safety valve
set at 7 bar, a check valve and a stop valve.
•
Make sure that the outlet of the safety unit goes directly to the sewer to avoid any
potential damage.
•
Do not install the safety group above the tank to avoid water discharge on to the
tank.
•
Make sure to install a domestic expansion vessel of the appropriate size to avoid
discharge from the safety valve (loss of water). Refer to the expansion vessel
manufacturer’s technical instructions for more details.
DE
PL
RU
en
14
Comfort E : A1002860 - 661Y1600 • D
INSTALLATION
EN
Essential instructions for the safety of persons and the environment
•
Hot water can burn!
In the event of small amounts of hot water repeatedly being drawn off, a
stratification effect can develop in the tank. The upper hot water layer may then
reach very high temperatures.
•
ACV recommends using a pre-set thermostatic mixing valve in order to provide
hot water at a maximum of 60°C.
•
Water heated to wash clothes, dishes and for other uses can cause serious burns.
•
In order to avoid exposure to extremely hot water that can cause serious burns,
never leave children, old people, disabled or handicapped people in the bath
or shower alone.
•
Never allow young children to turn on the hot water or fill their own bath.
•
Adjust the water temperature in accordance with usage and plumbing regulations.
•
The risk of developing bacteria exists, including “Legionella pneumophila”,
if a minimum temperature of 60°C is not maintained in both the DHW tank and the
hot water distribution network.
FR
NL
ES
IT
Essential instructions for the electrical safety
•
Only an approved installer is authorized to carry out the electrical connections.
•
Install a 2-way switch and a fuse or circuit breaker of the recommended rating
outside the appliance, so as to be able to shut power down when servicing the
appliance or before performing any operation on it.
•
Shut down external electrical supply of the appliance before performing any
operation on the electrical circuit.
•
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless supervised or unless they have been given instruction concerning the use
of the appliance by a person responsible for their safety.
DE
PL
RU
en
Comfort E : A1002860 - 661Y1600 • D
15
EN
INSTALLATION
PACKING CONTENTS
All appliances are delivered, tested and packaged separately.
FR
Package
•
•
•
•
NL
One Comfort E hot water tank.
One multilingual Installation, Operation and Maintenance Instructions.
One energy label
One wall-mounting kit with support and flow diverter
General Remarks
ES
•
The hot water tank must be installed on a wall using the provided wall-mounting
kit.
•
The appliance should be positioned to allow the replacement of the sparge tube
and dry well during servicing, if required.
Essential instruction for the correct operation of the installation
IT
•
The Comfort E models must be installed with the heating element to the bottom
(DHW pipes to the bottom).
TOOLS
DE
PL










RU
en
16
Comfort E : A1002860 - 661Y1600 • D
INSTALLATION
EN
TANK POSITION
FR
NL
ES
IT
DE
PL
RU
en
Comfort E : A1002860 - 661Y1600 • D
17
EN
INSTALLATION
CONNECTION
Essential instructions for the safety of persons and the environment
FR
NL
•
Refer to the safety instructions for the installation. Failure to comply with these
instructions can result in damages to the system, severe injuries or death.
•
Hot water can burn! ACV recommends using a pre- set thermostatic mixing valve
in order to provide hot water at a maximum of 60°C.
Essential instructions for the correct operation of the system
ES
•
The filling circuit of the DHW tank must be equipped with a safety group,
comprised at least of a stop valve, a check valve, a safety valve set at 7 bar, and
possibly, an expansion vessel of the appropriate size. Make sure that the circuit
between the tank and the safety valve is always open.
•
The third DHW tank connection, if any, can be used for the auxiliary DHW loop. If the
connection is not used, replace the protective plug by a brass plug of the appropriate
size.
General remarks
IT
•
In certain countries the domestic kits must be approved.
•
The circuit illustrations are basic principle diagrams only.
CONNECTION TO THE DHW CIRCUIT (Typ. vertical installation on a wall)
Key
1. Filling valve
2. Pressure reducing valve (set at 4.5 bar)
3. Check valve
4. Stop valve
5. DHW expansion vessel
6. Pressure gauge
7. Safety valve (set at 7 bar)
8. Drain valve
9. Grounding
10. Stop valve
11. Thermostatic mixing valve
12. Hot water outlet
DE
PL
RU
12
11
5
6 7
10
9
1
2
Cold water
Hot water
en
18
Comfort E : A1002860 - 661Y1600 • D
3
4
8
INSTALLATION
EN
CONNECTION TO THE PRIMARY CIRCUIT (Typ. vertical installation on a wall)
FR
Key
1. Primary circuit filling valve
2. Charging pump
3. Check valve
4. Primary circuit stop valve
5. Expansion vessel
6. Pressure gauge
7. Safety valve
8. Drain valve
9. Stop valve
1
2
NL
ES
3
4
IT
7
6
DE
9
4
5
8
PL
Cold water
RU
Hot water
en
Comfort E : A1002860 - 661Y1600 • D
19
EN
INSTALLATION
COMFORT E TANK USED AS ELECTRIC DHW TANK ONLY
Do not power the heating element if the oustide tank is not filled and bled.
FR
NL
1.
2.
3.
4.
5.
System filling valve
Safety valve calibrated to 3 bar
Expansion vessel
Isolation valve, heating system
Pressure gauge
This connection to
be plugged.
ES
4
2
5
IT
3
1
DE
AVAILABLE KITS AND ACCESSORIES
PL
DHW connection kit available
(code: 10800102)
A. DHW temperature control valve
B. Mixed domestic hot water outlet
C. Cold water supply
D. Drainage connection
E. DHW expansion vessel connection
S. Safety valve (7 bar)
TH. Tank hot water outlet
TC. Tank cold water inlet
RU
TH
A
E
B
en
20
S
TC
Comfort E : A1002860 - 661Y1600 • D
C
D
STARTING UP
EN
SAFETY INSTRUCTIONS TO FILL THE TANK
Essential instructions for the safety of persons and the environment
•
The DHW tank must always be filled and pressurised before filling and pressurising
the primary circuit.
•
Do not use vehicle antifreeze. This can cause serious injury or death, or damage
facilities.
•
If antifreeze is needed in the primary circuit, it must comply with Public
Hygiene Regulations and must be non-toxic. A food-grade Propylene Glycol is
recommended. It must be diluted according to the ratio recommended in the local
regulations.
•
Consult the manufacturer to determine the compatibility of the antifreeze with the
tank's construction materials.
FR
NL
ES
Essential instructions for the correct operation of the system
•
Before bringing the tank into service, check the connections to avoid any risk
of leaks during filling.
•
Only use drinking water to check that the DHW tank is watertight. The on-site
test pressure must not exceed a pressure surge of 8,6 bar.
•
Using antifreeze in the primary circuit will lead to a reduction in the heating
performance. The higher the concentration of antifreeze in the circuit, the lower
the performance.
IT
DE
PL
RU
en
Comfort E : A1002860 - 661Y1600 • D
21
EN
STARTING UP
FILLING
Essential instruction for the correct operation of the system
FR
•
The DHW tank must always be filled and pressurised before filling and pressurising
the primary circuit.
FILLING THE DHW TANK (Figure 1)
NL
General remark
•
ES
IT
Connect the safety valve outlet to the sewer.
1.
To fill the tank, open a hot water tap (2) located at the highest point of the system. It enables
to bleed the air from the system.
2.
Open the filling valve (1) and the stop valves (3) to fill the DHW tank.
3.
Close the hot water tap (2), after the water flow has stabilised and the air has been
completely evacuated.
4.
Check all the connections of the system for leaks.
DE
FILLING THE PRIMARY CIRCUIT (Figure 2)
General remark
PL
•
RU
If the tank is used within a heating system, refer to the heating boiler manual.
1.
Check that the drain valve (3) of your primary circuit is tightly closed.
2.
Open the stop valves (1) and (2) of the primary circuit connected to the heating boiler.
3.
Open the air bleed valve (4) located on the top of the hot water tank.
4.
When the air is eliminated, close the air bleed valve (4). Make sure the air bleed valve is tight.
en
22
Comfort E : A1002860 - 661Y1600 • D
STARTING UP
EN
2
FR
NL
ES
3
3
1
IT
Figure 1
DE
Cold water
4
Hot water
1
2
PL
RU
1
2
3
Figure 2
en
Comfort E : A1002860 - 661Y1600 • D
23
EN
STARTING UP
CHECKS BEFORE STARTING UP
• Check that the safety valves (DHW and primary) are correctly installed and that the outlets are
connected to the sewer.
FR
• Check that the DHW tank and the primary circuit are filled with water.
• Check that the air has been correctly bled from both circuits.
• Check that the tank’s upper air bleed valve is tight.
NL
• Check that the water side and heat source side pipes are correctly connected and not leaking.
STARTING UP PROCEDURE
ES
If the tank is used as an electric DHW tank only :
To put the installation into service, refer to the heating boiler manual.
1. Put the electric plug into the mains socket
IT
2.
Set the Summer / Winter switch on the summer ( ) position and check that the indicator
is on.
3.
Adjust the required temperature using the control thermostat.
If the tank is used within a heating installation:
DE
To put the installation into service, refer to the heating boiler manual.
PL
1.
Put the Summer / Winter switch on the winter ( ) position and check that the indicator is
off.
2.
Adjust the required temperature using the control thermostat.
RU
en
24
Comfort E : A1002860 - 661Y1600 • D
MAINTENANCE
EN
PERIODIC CHECKS BY THE USER
• Check the pressure of the primary circuit pressure gauge: it should be between 0.5 and 1.5 bar.
FR
• Visually inspect, on a regular basis, the valves, connections and accessories in order to detect
any leaks or malfunction.
• Periodically check the air bleed valve located on the tank top to ensure that it is not leaking.
• Check that the DHW water circuit safety valves are in good operating condition.
• In the event of a problem, please contact an engineer or your installer.
NL
ANNUAL MAINTENANCE
Essential instructions for the correct operation of the appliance
•
The discharge pipe of the safety unit must be open to the outside. If the safety
unit drips periodically, it may be due to an expansion problem or clogging of the
valve.
•
For internal inspections, the hand hole can be used. If there is none, use one of the
water connections to insert the appropriate inspection equipment. If necessary,
drain the tank before inspection.
ES
IT
The annual maintenance service, performed by an engineer, must include:
•
A check of the air bleed valve: the bleeding of air can lead to the need for adding water to
the system.
•
A check of the primary and DHW circuit pressure gauges.
•
The manual activation of the storage water circuit safety valve once a year. This operation
will lead to a discharge of hot water.
•
A check of the correct operation of valves, taps, control units and accessories that are
possibly installed [refer to the manufacturer's instructions if necessary].
DE
PL
RU
en
Comfort E : A1002860 - 661Y1600 • D
25
EN
MAINTENANCE
DRAINING
Essential instruction for the safety of persons and the environment
FR
•
The water coming out of the drain valve is very hot and can cause very severe
burns. Make sure the area around the hot water flow is clear of people.
Essential instruction for the electrical safety
•
NL
Shut down the external electrical supply of the appliance before draining.
Essential instructions for the correct operation of the system
•
Drain the tank if it is not used in winter and is at risk from exposure to ice. If the
primary circuit water contains antifreeze, only the DHW tank must be drained. If
the heating circuit does not contain antifreeze, the heating circuit and domestic
water must be drained.
•
Before draining the DHW, isolate the tank and lower the pressure of the heating
circuit to 1 bar, in order to prevent the DHW tank from being crushed.
ES
DRAINING THE PRIMARY CIRCUIT (Figure 3)
IT
To drain the primary circuit of the hot water heater:
1.
2.
3.
4.
5.
6.
DE
Stop the charging pump.
Isolate the primary circuit by closing the stop valves (1).
Connect the drain valve (2) to the sewer using a flexible hose.
Open the drain valve (2) and drain the water from the primary circuit to the drain.
Open the tank’s air bleed valve (3) to accelerate drainage.
Close the drain valve (2) and air bleed valve (3) after draining the tank.
DRAINING THE DHW TANK (Figure 4)
PL
To drain the hot water heater’s DHW tank:
1.
2.
3.
4.
5.
RU
6.
Open fully the hot water tap (3) for at least 60 minutes to make sure the DHW tank has
cooled down sufficiently.
Close the filling valve (1) and the stop valve (4).
Connect the drain valve (2) to the sewer using a flexible hose.
Open the drain valve (2) and drain the water from the DHW tank to the sewer.
To accelerate the tank’s drainage, open a hot water tap located higher than the tank
connection in the DHW circuit.
Close the drain valve (2) and the hot water tap (3) after having drained the DHW tank.
BRINGING BACK INTO SERVICE AFTER MAINTENANCE
Refer to chapter "Starting Up", page 21
en
26
Comfort E : A1002860 - 661Y1600 • D
MAINTENANCE
EN
3
FR
1
NL
ES
1
2
IT
Figure 3
Cold water
DE
Hot water
3
PL
RU
1
4
2
Figure 4
en
Comfort E : A1002860 - 661Y1600 • D
27
EN
MAINTENANCE
REPLACEMENT OF THE ELECTRIC HEATING ELEMENT
FR
•
Switch off and disconnect the mains power supply to the appliance.
•
Be careful with the high temperature of the cylinder.
•
Drain the primary tank.
NL
ES
IT
DE
PL
4
2
RU
Max = 5,5 Nm
Min = 4,8 Nm
3
1
en
28
Comfort E : A1002860 - 661Y1600 • D
MAINTENANCE
EN
FAULT FINDING
What to do if the domestic hot water is not heated anymore?
1
Check the power supply.
2
Check the proper operation of the boiler and the control thermostat of the tank.
3
Check if the load pump works properly and replace if necessary.
4
Check the fuse and replace if necessary.
5
Check the safety thermostat on the tank and reset if necessary.
6
Check the heating element and replace if necessary.
FR
NL
ES
IT
1.
2.
3.
4.
5.
6.
Control thermostat [60/80°C]
Heating-element-on indicator
Summer/Winter switch
Fuse FF 12,5 A
Manual reset high limit thermostat [89°C max.]
Electric heating element
DE
PL
2
RU
1
5
4
3
6
en
Comfort E : A1002860 - 661Y1600 • D
29
EN
FR
NL
ES
IT
DE
PL
RU
en
30
Comfort E : A1002860 - 661Y1600 • D