ROOM AIR CONDITIONER
OPERATING MANUAL
English
WALL MOUNTED TYPE
R410A
REFRIGERANT
This Air Conditioner contains and operates
with refrigerant R410A and Polyol Ester oil.
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED
BY QUALIFIED PERSONNEL.
Refer to Commonwealth, State, Territory and local legislation,
regulations, codes, installation & operation manuals, before
the installation, maintenance and/or service of this product.
KEEP THIS MANUAL FOR FUTURE REFERENCE
P/N9318657005
CONTENTS
SAFETY PRECAUTIONS .................................... En-1
FEATURES AND FUNCTIONS ........................... En-2
NAME OF PARTS ................................................ En-4
PREPARATION .................................................... En-5
OPERATION ........................................................ En-6
TIMER OPERATION ............................................ En-8
SLEEP TIMER OPERATION ................................ En-9
ADJUSTING THE DIRECTION OF
AIR CIRCULATION ........................................... En-10
10°C HEAT OPERATION ...................................
ECONOMY OPERATION ...................................
SWING OPERATION .........................................
MANUAL AUTO OPERATION ..........................
CLEANING AND CARE .....................................
TROUBLESHOOTING .......................................
OPERATING TIPS ..............................................
En-11
En-11
En-12
En-12
En-13
En-15
En-16
SAFETY PRECAUTIONS
● Before using the appliance, read these “PRECAUTIONS” thoroughly and operate in the correct way.
● The instructions in this section all relate to safety; be sure to maintain safe operating conditions.
● “DANGER”, “WARNING” and “CAUTION” have the following meanings in these instructions:
DANGER!
This mark indicates procedures which, if improperly performed, are most likely to
result in the death of or serious injury to the user or service personnel.
WARNING!
This mark indicates procedures which, if improperly performed, might lead to the
death or serious injury of the user.
CAUTION!
This mark indicates procedures which, if improperly performed, might possibly result
in personal harm to the user, or damage to property.
DANGER!
CAUTION!
● Do not attempt to install this air conditioner by yourself.
● This air conditioner contains no user-serviceable parts. Always consult authorized service personnel for repairs.
● When moving, consult authorized service personnel for disconnection and installation of the air conditioner.
● Do not become excessively chilled by staying for many hours in the direct cooling airflow.
● Do not insert fingers or objects into the outlet port or intake grille.
● Do not start and stop air conditioner operation by disconnecting the power supply
cord and so on.
● Take care not to damage the power supply cord.
● In the event of a malfunction (burning smell, etc.), immediately stop operation, turn
off the electrical breaker, and consult authorized service personnel.
● If the power supply cord of this appliance is damaged, it should only be replaced by the
authorized service personal, since special purpose tools and specified cord are required.
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
En-1
Provide occasional ventilation during use.
Do not direct airflow at fireplaces or heating apparatus.
Do not climb on, or place objects on, the air conditioner.
Do not hang objects from the indoor unit.
Do not set flower vases or water containers on top of air conditioners.
Do not expose the air conditioner directly to water.
Do not operate the air conditioner with wet hands.
Do not pull power supply cord.
Turn off power supply when not using the indoor unit for extended periods.
Check the condition of the installation stand for damage.
Do not place animals or plants in the direct path of the airflow.
Do not drink the water drained from the air conditioner.
Do not use in applications involving the storage of foods, plants or animals, precision
equipment, or art works.
Connection valves become hot during Heating; handle with care.
Do not apply any heavy pressure to radiator fins.
Operate only with air filters installed.
Do not block or cover the intake grille and outlet port.
SAFETY PRECAUTIONS
CAUTION!
● Ensure that any electronic equipment is at least one meter away from either the indoor or outdoor units.
● Avoid installing the air conditioner near a fireplace or other heating apparatus.
● When installing the indoor and outdoor unit, take precautions to prevent access to
infants.
● Do not use inflammable gases near the air conditioner.
● This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised to ensure that they
do not play with the appliance.
FEATURES AND FUNCTIONS
INVERTER
At the start of operation, a large power is used to bring the
room quickly to the desired temperature. Afterward, the air
conditioner automatically switches to a low power setting
for economic and comfortable operation.
SUPER QUIET OPERATION
When the FAN button is used to select QUIET, the indoor
unit begins super-quiet operation; the indoor unit’s airflow
is reduced to produce quieter operation.
AIR CLEANING FILTER
AUTO CHANGEOVER
The operation mode (cooling, dry, heating) is switched automatically to maintain the set temperature, and the temperature is kept constant at all times.
10°C HEAT OPERATION
The room temperature can be maintained at 10°C so as to
prevent the room temperature from falling too far.
ECONOMY OPERATION
When economy operation mode is operated, the room temperature will be little higher than the set-temp under cooling mode and lower than set-temp under heating mode.
Therefore, the economy mode is able to save more energy
than other normal mode.
PROGRAM TIMER
The program timer allows you to integrate OFF timer and
ON timer operations in a single sequence. The sequence can
involve one transition from OFF timer to ON timer, or from
ON timer to OFF timer, within a twenty-four hour period.
SLEEP TIMER
Air cleaning filter uses static electricity to clean fine particles
and dust in the air such as tobacco smoke and plant pollen
that are too small to see.
The filter contains catechin, which is highly effective against
various bacteria by suppressing the growth of the bacteria
adsorbed to the filter.
Note that when the air cleaning filter is installed, the amount
of air produced decreases, causing a slight decrease in the
indoor unit’s performance.
WIRED REMOTE CONTROLLER (OPTION)
The optional wired remote controller can be used.
When you use remote controller, there are following different
points as compared with using wireless remote controller.
[The additional functions for wired ones]
• Weekly timer
• Temperature set back timer
And you can use both wired and wireless remote controller
simultaneously.
(But function is limited)
When the restricted functions on the remote controller are
used, beeping sound will be heard, OPERATION, TIMER and
the 3rd lamp of the indoor unit will flash.
[The restricted functions for wireless ones]
• SLEEP TIMER
• TIMER
• 10˚C HEAT
When the SLEEP button is pressed during Heating mode,
the indoor unit’s thermostat setting is gradually lowered
during the period of operation; during cooling mode, the
thermostat setting is gradually raised during the period of
operation. When the set time is reached, the indoor unit automatically turns off.
WIRELESS REMOTE CONTROLLER
The Wireless Remote Controller allows convenient control
of indoor unit operation.
SWING OPERATION
The Airflow Direction Louvers swings automatically up and
down so that the air speeds to every nook and corner of
your room.
En-2
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
To facilitate explanation, the accompanying illustration has been drawn to show all possible indicators; in actual operation, however, the display will
only show those indicators appropriate to the
current operation.
En-3
NAME OF PARTS
Fig. 1 Indoor Unit
Fig. 5 Remote Controller
1 Operating Control Panel (Fig. 2)
2 MANUAL AUTO button
● When kept on pressing the MANUAL
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
AUTO button for more than 10 seconds,
the forced cooling operation will start.
● The forced cooling operation is used at the
time of installation.
Only for authorized service personnel's
use.
● When the forced cooling operation starts
by any chance, press the START/STOP button to stop the operation.
● Please press the button at FILTER INDICATOR RESET.
3
4
5
6
Indicator (Fig. 3)
Remote Control Signal Receiver
OPERATION Indicator Lamp (green)
TIMER Indicator Lamp (orange)
● If the TIMER indicator lamp flashes when
● This button is used when installing the air
conditioner, and should not be used under normal conditions, as it will cause the
indoor unit’s thermostat function to operate incorrectly.
the timer is operating, it indicates that a
fault has occurred with the timer setting
(See Page 16 Auto Restart).
7
8
9
0
A
B
C
ECONOMY Indicator Lamp (green)
DEFROST Indicator Lamp (green)
Intake Grille (Fig. 4)
Front Panel
Air Filter
Airflow Direction Louver
Right-Left Louver
(behind Airflow Direction Louver)
D Drain Hose
E Air Cleaning Filter
F Remote Controller (Wired/Option)
Signal Transmitter
MODE button
10°C HEAT button
SET TEMP. button (
/
)
ECONOMY button
SLEEP button
TIMER MODE button
FAN button
START/STOP button
SET button
SWING button
TIMER SET (
/
) button
CLOCK ADJUST button
TEST RUN button
● If this button is pressed during normal operation, the indoor unit will switch to test
operation mode, and the Indoor Unit’s OPERATION Indicator Lamp and TIMER
Indicator Lamp will begin to flash simultaneously.
● To stop the test operation mode, press the
START/STOP button to stop the air
conditioner.
U
V
W
X
Y
Z
[
\
]
^
RESET button
Remote Controller Display (Fig. 6)
Transmit Indicator
Fan Speed Display
SWING Display
Timer Mode Display
Clock Display
Temperature SET Display
Operation Mode Display
SLEEP TIMER Display
En-4
PREPARATION
CAUTION!
Turn on the Power
1
Turn on the circuit breaker.
Load Batteries (R03/LR03 × 2)
1
Press and slide the battery compartment lid on the reverse side to open it.
Slide in the direction of the arrow while pressing the
2
Insert batteries.
3
Close the battery compartment lid.
Be sure to align the battery polarities (
mark.
) correctly.
Set the Current time
1
2
Press the CLOCK ADJUST button (Fig. 5 S).
Use the tip of a ball-point pen or other small object to press the button.
Use the TIMER SET (
/
) buttons (Fig. 5 R) to
adjust the clock to the current time.
button: Press to advance the time.
button: Press to reverse the time.
(Each time the buttons are pressed, the time will be advanced/reversed
in one-minute increments; hold the buttons depressed to change the time
quickly in ten-minute increments.)
3
Press the CLOCK ADJUST button (Fig. 5 S) again.
This completes the time setting and starts the clock.
To Use the Remote Controller
● The Remote Controller must be pointed at signal receiver (Fig. 1 4) to operate
correctly.
● Operating Range: About 7 meters.
● When a signal is properly received by the indoor unit, a beeping sound will be
heard.
● If no beep is heard, press the Remote Controller button again.
Remote Controller Holder
Insert
Slide up
Press in
Pull out
Screws
1 Mount the Holder. 2 Set the Remote Controller.
En-5
3 To remove the Remote
Controller (when use at
hand).
● Take care to prevent infants from
accidentally swallowing batteries.
● When not using the Remote Controller
for an extended period, remove the
batteries to avoid possible leakage and
damage to the unit.
● If leaking battery fluid comes in contact
with your skin, eyes, or mouth, immediately wash with copious amounts of
water, and consult your physician.
● Dead batteries should be removed
immediately and disposed of properly,
either in a battery collection receptacle
or to the appropriate authority.
● Do not attempt to recharge dry batteries.
Never mix new and used batteries, or
batteries of different types.
Batteries should last about one year
under normal use. If the Remote
Controller’s operating range becomes
appreciably reduced, replace the batteries and press the RESET button with the
tip of a ballpoint pen or other small
object.
OPERATION
To Select Mode Operation
1
Press the START/STOP button (Fig.5 O).
2
Press the MODE button (Fig.5 H) to select the desired
mode.
The indoor unit’s OPERATION Indicator Lamp (green) (Fig. 3 5) will light.
The air conditioner will start operating.
Each time the button is pressed, the mode will change in the following
order.
s AUTO
s COOL
s DRY
HEAT t
FAN t
About three seconds later, the entire display will reappear.
To Set the Thermostat
Example: When set to COOL.
Press the SET TEMP. button (Fig. 5 J).
button: Press to raise the thermostat setting.
button: Press to lower the thermostat setting.
●Thermostat setting range:
AUTO .................................. 18-30 °C
Heating ............................... 16-30 °C
Cooling/Dry ........................ 18-30 °C
The thermostat cannot be used to set room temperature during the FAN mode (the
temperature will not appear on the Remote Controller’s Display).
About three seconds later, the entire display will reappear.
The thermostat setting should be considered a standard value, and may differ
somewhat from the actual room temperature.
Example: When set to 26 °C.
To Set the Fan Speed
Press the FAN button (Fig. 5 N).
Each time the button is pressed, the fan speed changes in the following order:
sAUTO
s HIGH
s
MED
sLOW
s QUIET
About three seconds later, the entire display will reappear.
When set to AUTO:
Heating : Fan operates so as to optimally circulate warmed air.
However, the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low.
Cooling : As the room temperature approaches that of the thermostat setting,
the fan speed becomes slower.
Fan
: The fan runs at the low fan speed.
Example: When set to AUTO.
The fan will operate at a very low setting during Monitor operation and at the
start of the Heating mode.
SUPER QUIET Operation
SUPER QUIET operation begins. The indoor unit’s airflow will be reduced for quieter operation.
● SUPER QUIET operation cannot be used during Dry mode. (The same is true
when dry mode is selected during AUTO mode operation.)
● During Super Quiet operation, Heating and Cooling performance will be reduced
somewhat. If the room does not warm up/ cool down when using SUPER QUIET
Operation, please adjust the indoor unit’s Fan Speed.
En-6
OPERATION
To Stop Operation
Press the START/STOP button (Fig. 5 O).
The OPERATION Indicator Lamp (green) (Fig. 3 5) will go out.
About AUTO CHANGEOVER Operation
AUTO:
● When AUTO CHANGEOVER operation first selected, the fan will operate at very low speed for about two minute, during which time the
indoor unit detects the room conditions and selects the proper operation mode.
If the difference between thermostat setting and actual room temperature is more than +2 °C → Cooling or dry operation
(Monitor operation may be selected if the outdoor temperature is low.)
If the difference between thermostat setting and actual room temperature is within ±2 °C → Monitor operation
If the difference between thermostat setting and actual room temperature is more than –2 °C → Heating operation
(Monitor operation may be selected if the outdoor temperature is high.)
● When the indoor unit has adjusted your room’s temperature to near
the thermostat setting, it will begin monitor operation. In the monitor
operation mode, the fan will operate at low speed. If the room temperature subsequently changes, the indoor unit will once again select
the appropriate operation (Heating, Cooling) to adjust the temperature
to the value set in the thermostat.
(The monitor operation range is ±2 °C relative to the thermostat setting.)
● If the mode automatically selected by the indoor unit is not what you
wish, select one of the mode operation (HEAT, COOL, DRY, FAN).
About Mode Operation
Heating: ● Use to warm your room.
● When Heating mode is selected, the indoor unit will operate at very
low fan speed for about 3 to 5 minutes, after which it will switch to the
selected fan setting. This period of time is provided to allow the indoor
unit to warm up before begin full operation.
● When the room temperature is very low, frost may form on the outdoor
unit, and its performance may be reduced. In order to remove such
frost, the air conditioner will automatically enter the defrost cycle from
time to time. During Automatic Defrosting operation, the OPERATION
Indicator Lamp (Fig. 3 5) will flash, and the DEFROST Indicator Lamp
(Fig.3 8) will light, and the heat operation will be interrupted.
Cooling: ● Use to cool your room.
Dry:
● Use for gently cooling while dehumidifying your room.
● You cannot heat the room during Dry mode.
● During Dry mode, the indoor unit will operate at low speed; in order to
adjust room humidity, the indoor unit’s fan may stop from time to time.
Also, the fan may operate at very low speed when adjusting room
humidity.
● The fan speed cannot be changed manually when Dry mode has been
selected.
Fan:
En-7
● Use to circulate the air throughout your room.
During Heating mode:
Set the thermostat to a temperature setting that is higher than the present room
temperature. The Heating mode will not
operate if the thermostat is set lower than
the actual room temperature.
During Cooling/Dry mode:
Set the thermostat to a temperature setting that is lower than the present room
temperature. The Cooling and Dry modes
will not operate if the thermostat is set
higher than the actual room temperature
(in Cooling mode, the fan alone will operate).
During Fan mode:
You can not use the indoor unit to heat
and cool your room.
TIMER OPERATION
Before using the timer function, be sure that the Remote Controller is set to the correct current time (☞ P. 5).
To Use the ON timer or OFF timer
1
Press the START/STOP button (Fig. 5 O)
(if the indoor unit is already operating, proceed to step 2).
The indoor unit’s OPERATION Indicator Lamp (green) (Fig. 3 5) will light.
2
Press the TIMER MODE button (Fig. 5 M) to select the
OFF timer or ON timer operation.
Each time the button is pressed the timer function changes in the following order:
s CANCEL
s OFF
sON
PROGRAM(OFF → ON, OFF ← ON) t
The indoor unit’s TIMER Indicator Lamp (orange) (Fig. 3 6) will light.
3
Use the TIMER SET buttons (Fig. 5 R) to set the desired OFF time or ON time.
To Cancel the Timer
Use the TIMER button to select “CANCEL”.
The indoor unit will return to normal
operation.
To Change the Timer Settings
Perform steps 2 and 3.
To Stop Air Conditioner Operation
while the Timer is Operating
Press the START/STOP button.
To Change Operating Conditions
If you wish to change operating conditions
(Mode, Fan Speed, Thermostat Setting,
SUPER QUIET mode), after making the
timer setting and waiting until the entire
display reappears, then press the appropriate buttons to change the operating
condition desired.
Set the time while the time display is flashing (the flashing will continue
for about five seconds).
button: Press to advance the time.
button: Press to reverse the time.
About five seconds later, the entire display will reappear.
To Use the Program timer
1
Press the START/STOP button (Fig. 5 O)
(if the indoor unit is already operating, proceed to step 2).
The indoor unit’s OPERATION Indicator Lamp (green) (Fig. 3 5) will light.
2
3
Set the desired times for OFF timer and ON timer.
See the section “To Use the ON timer or OFF timer” to set the desired
mode and times.
About three seconds later, the entire display will reappear.
The indoor unit’s TIMER Indicator Lamp (orange) (Fig. 3 6) will light.
Press the TIMER MODE button (Fig. 5 M) to select the
ON or OFF
ON
PROGRAM timer operation (OFF
will display).
The display will alternately show “OFF timer” and “ON timer”, then change
to show the time setting for the operation to occur first.
● The program timer will begin operation. (If the ON timer has been selected to operate first, the indoor unit will stop operating at this point.)
About five seconds later, the entire display will reappear.
About the Program timer
● The program timer allows you to integrate OFF timer and ON timer operations in
To Cancel the Timer
Use the TIMER MODE button to select
“CANCEL”.
The air conditioner will return to normal
operation.
To Change the Timer Settings
1. Follow the instructions given in the section
“To Use the ON Timer or OFF Timer” to select the timer setting you wish to change.
2. Press the TIMER MODE button to select
either OFF
ON or OFF
ON.
To Stop Air Conditioner Operation
while the Timer is Operating
Press the START/STOP button.
To Change Operating Conditions
If you wish to change operating conditions
(Mode, Fan Speed, Thermostat Setting,
SUPER QUIET mode), after making the timer
setting and waiting until the entire display
reappears, then press the appropriate
buttons to change the operating condition
desired.
a single sequence. The sequence can involve one transition from OFF timer to
ON timer, or from ON timer to OFF timer, within a twenty-four hour period.
● The first timer function to operate will be the one set nearest to the current time.
The order of operation is indicated by the arrow in the Remote Controller’s Display
(OFF → ON, or OFF ← ON).
● One example of Program timer use might be to have the air conditioner auto-
matically stop (OFF timer) the operation after you go to sleep, then start (ON
timer) the operation automatically in the morning before you arise.
En-8
SLEEP TIMER OPERATION
Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operation is stopped.
To Use the SLEEP Timer
While the air conditioner is operating or stopped, press the
SLEEP button (Fig. 5 L).
The indoor unit’s OPERATION Indicator Lamp (green) (Fig. 3 5) lights and the TIMER
Indicator Lamp (orange) (Fig. 3 6) light.
To Cancel the Timer:
Use the TIMER MODE button to select
“CANCEL”.
The air conditioner will return to normal
operation.
To Stop the Air Conditioner During
Timer Operation:
To Change the Timer Settings
Press the START/STOP button.
Press the SLEEP button (Fig. 5 L) once again and set the time
/
) buttons (Fig. 5 R).
using the TIMER SET (
Set the time while the Timer Mode Display is flashing (the flashing will continue
about five seconds).
button: Press to advance the time.
button: Press to reverse the time.
About five seconds later, the entire display will reappear.
About the SLEEP Timer
To prevent excessive warming or cooling during sleep, the SLEEP timer function automatically modifies the thermostat setting
in accordance with the set time setting. When the set time has elapsed, the air conditioner completely stops.
During Heating operation:
When the SLEEP timer is set, the thermostat setting is
automatically lowered 1 °C every thirty minutes. When the
thermostat setting is lowered a total of 4 °C, the thermostat
setting at that time is maintained until the set time elapses, at
which time the air conditioner automatically turns off.
SLEEP timer setting
During Cooling/Dry operation:
When the SLEEP timer is set, the thermostat setting is automatically raised 1 °C every sixty minutes. When the thermostat setting is raised a total of 2 °C, the thermostat setting at
that time is maintained until the set time elapses, at which
time the air conditioner automatically turns off.
SLEEP timer setting
Set temp.
1 °C
Set time
2 °C
3 °C
4 °C
1 hour
30
minutes
1 hour
Set temp.
1 hour
30 minutes
Set time
En-9
1 °C
2 °C
ADJUSTING THE DIRECTION OF AIR CIRCULATION
Vertical (up-down) direction of airflow is adjusted by pressing the Remote Controller’s SET button. Horizontal (right-left) Airflow
direction is adjusted manually, by moving the Airflow Direction Louvers.
Whenever making horizontal airflow adjustments, start air conditioner operation and be sure that the vertical Airflow direction
louvers are stopped.
R DANGER!
Vertical Airflow Direction Adjustment
Press the SET button (Fig. 5 P).
Each time the button is pressed, the Airflow direction range will change as follows:
1
2
3
4
5
6
Types of Airflow Direction Setting:
1,2,3 : During Cooling/Dry modes
4,5,6 : During Heating mode
The Remote Controller’s display does
not change.
● Use the Airflow direction adjustments within the ranges shown above.
● The vertical Airflow direction is set automatically as shown, in accordance with
the type of operation selected.
During Cooling/Dry mode : Horizontal flow 1
During Heating mode
● Never place fingers or foreign objects inside the outlet ports, since the internal fan
operates at high speed, and personal injury
could be caused.
: Downward flow 5
● After beginning of AUTO/HEAT mode operated and automatic defrosting operation time (see page 16), the airflow will be horizontal 1.
However, the Airflow direction cannot be adjusted at beginning AUTO operation mode.
Right-Left Adjustment
Adjust the Right-Left louvers.
● Move the Right-Left louvers to adjust air flow in the direction you prefer.
● Always use the Remote Controller’s
SET button to adjust the vertical airflow
louvers. Attempting to move them
manually could result in improper
operation; in this case, stop operation
and restart. The louvers should begin
to operate properly again.
● During use of the Cooling and Dry
modes, do not set the Airflow Direction Louvers in the Heating range (4 6) for many hours, since water vapor
may condense near the outlet louvers
and drops of water may drip from the
indoor unit. During the Cooling and
Dry modes, if the Airflow Direction
Louvers are left in the heating range
for more than 30 minutes, they will
automatically return to position 3.
● When used in a room with infants, children, elderly or sick persons, the Airflow
direction and room temperature should
be considered carefully when making
settings.
R DANGER!
● When adjusting the Right-Left Louvers, it
is necessary to stop the Air-Conditioner
first and make sure that it stops completely
before adjusting the direction.
knob
Right-Left Louvers
(two places)
knob
En-10
10°C HEAT OPERATION
• The room temperature can be maintained at 10°C by pressing the 10°C HEAT button
(Fig.5 G) so as to prevent the room temperature from falling too far.
To use 10°C HEAT OPERATION
Press the 10°C HEAT button (Fig.5 I)
To stop 10°C HEAT OPERATION
Press the START/STOP button (Fig.5 O)
Then the operation stops.
About the 10°C HEAT OPERATION
While 10˚C HEAT OPERATION is in
progress, only Airflow direction set
can be used.
● Indicator Lamp
OPERATION
TIMER
ECONOMY
DEFROST
: Lighting
: OFF
• The Heating mode will not operate if the room temperature is high enough.
• In case of multi-type air conditioner, if other indoor unit is used for heating, the temperature of the room where the “10°C
HEAT” function is applied will rise. When using the “10°C HEAT” function, we recommend all indoor units should be run
under the“10°C HEAT” mode.
ECONOMY OPERATION
Begin Air Conditioner operation before performing this procedure.
To Use the ECONOMY Operation
Press the ECONOMY button (Fig.5 K).
The indoor units ECONOMY Indicator Lamp ( green ) (Fig.3 7) will light.
Economy operation begins.
To Stop the ECONOMY Operation
● Indicator Lamp
OPERATION
TIMER
ECONOMY
DEFROST
: Lighting
: OFF
Press the ECONOMY button (Fig.5 K) again.
The ECONOMY Indicator Lamp ( green ) (Fig.3 7) will go out.
Normal operation begins.
About ECONOMY Operation
In case of single-type air conditioner, at the maximum output, ECONOMY Operation is approximately 70% of normal air
conditioner operation for cooling and heating.
• During ECONOMY operation, the thermostat setting automatically changes according to the temperature to avoid Unnecessary cooling and heating for the most economical operation.
● If the room is not cooled (or heated) well during economy operation, select normal operation.
● During the monitor period in the AUTO mode, the air conditioner operation will not change to ECONOMY operation even if
ECONOMY operation is selected by pressing the ECONOMY operation button.
● When economy operation mode is operated, the room temperature will be little higher than the set-temp under cooling
mode and lower than set-temp under heating mode. Therefore, the economy mode is able to save more energy than other
normal mode.
● In case of multi-type air conditioner, the economy operation mode is only available for the set indoor unit.
En-11
SWING OPERATION
Begin air conditioner operation before performing this procedure.
To select SWING Operation
Press the SWING button (Fig. 5 Q).
The SWING Display (Fig. 6 Y) will light.
In this mode, the Airflow Direction Louvers will swing automatically to direct the air
flow both up and down.
To stop SWING Operation
Press the SWING button (Fig. 5 Q) once again.
The SWING Display (Fig. 6 Y) will go out.
Airflow direction will return to the setting before swing was begun.
About Swing Operation
During cooling/Dry mode : Swings between 1 and 3.
During heating mode
: Swings between 3 and 6.
● The SWING operation may stop temporarily when the air conditioner’s fan is not
operating, or when operating at very low speeds.
MANUAL AUTO OPERATION
Use the MANUAL AUTO operation in the event the Remote Controller is lost or otherwise unavailable.
How To Use the Main Unit Controls
Press the MANUAL AUTO button (Fig. 2 2) for three seconds
on the main unit control panel.
To stop operation, press the MANUAL AUTO button (Fig. 2 2) for three seconds.
● When the air conditioner is operated
by the controls on the Main Unit, it will
operate under the same mode as the
AUTO mode selected on the Remote
Controller (see page 7).
● The fan speed selected will be “AUTO”
and the thermostat setting will be
standard (24°C).
En-12
CLEANING AND CARE
● Before cleaning the unit, be sure to stop the unit.
● Turn off the electrical breaker.
● When removing or replacing the air filters, be sure not to touch the heat exchanger, as personal
injury may result.
CAUTION!
Cleaning the Air Filter
1. Open the Intake Grille, and remove the air filter.
Lift up the air filter’s handle, disconnect the two lower tabs, and pull out.
handle Air filter (Right & Left)
1
1
2
2
Hooks (two places)
2. Remove dust with a vacuum cleaner or by washing.
After washing, allow to dry thoroughly in a shaded place.
3. Replace the Air Filter and close the Intake Grille.
1 Align the sides of the air filter with the panel, and push in fully, making sure the two lower tabs are returned properly to
their holes in the panel.
2 Close the Intake Grille.
Hooks (two places)
(For purposes of example, the illustration shows the indoor unit without Intake Grille installed.)
● Dust can be cleaned from the air filter either with a vacuum cleaner, or by washing the filter in a solution of neutral
detergent and warm water. If you wash the filter, be sure to allow it to dry thoroughly in a shady place before reinstalling.
● If dust is allowed to accumulate on the air filter, airflow will be reduced, lowering operating efficiency and increasing noise.
● During periods of normal use, the Air Filters should be cleaned every two weeks.
● Don't operate the air conditioner with being opened the intake grille.
● When used for extended periods, the indoor unit may accumulate dust inside, reducing its performance. We recommend
that the indoor unit be inspected regularly, in addition to your own cleaning and care. For more information, consult
authorized service personnel.
● When cleaning the indoor unit’s body, do not use water hotter than 40 °C, harsh abrasive cleansers, or volatile agents like
benzene or thinner.
● Do not expose the indoor unit’s body to liquid insecticides or hairsprays.
● When shutting down the indoor unit for one month or more, first allow the fan mode to operate continuously for about
one-half day to allow internal parts to dry thoroughly.
En-13
CLEANING AND CARE
Air Cleaning Filter Installation
1. Open the Intake Grille and remove the Air
filters.
2. Attach the air cleaning filter to the frame
of the front panel.
2. Remove the air cleaning filters attached
to the frames of the front panel.
Air cleaning filter frame
● Attach the filter on the inside of the tabs (7 places) so
as not to stick out.
Air cleaning filter frame
3. Replace them by two new Air cleaning
filters.
Tabs (7 places)
Air cleaning filter frame
2 Install in the same way as for installation of the air
cleaning filter set.
Tabs (6 places)
Air cleaning filter
1 Remove the old air cleaning filters in reverse order of
their installation.
Tabs (7 places)
4. Install the two Air filters and close the
Intake Grille.
● Don't operate the air conditioner with being opened
the intake grille.
(In the above figure, the intake grille is omitted for
the explanation)
About the Air Cleaning Filters
3. Install the two Air filters and close the
Intake Grille.
● Don't operate the air conditioner with being opened
the intake grille.
● When air cleaning filters are used, the effect will increased
by setting the fan speed to “High”.
Replacing dirty Air cleaning filters
Replace filters with the following components (purchased
separately).
● AIR CLEANING FILTER : UTR-FA16-3
1. Open the Intake Grille and remove the Air
filters.
AIR CLEANING FILTER (Two sheet)
● The Air Cleaning Filters are disposable filters. (They can
not be washed and reused.)
● For storage of the Air Cleaning Filters, use the filters as
soon as possible after opening the package.
(The air cleaning effect decreases when the filters are left
in the opened package)
● In order to maintain the air cleaning effect, it is
recommended to replace the filter every 3 years.
Please buy designed air cleaning filters (UTR-FA16-3) (Sold
separately) to exchange the used dirty air cleaning filter.
Maintenance of Air Cleaning Filters
In order to maintain the air cleaning effect, please clean the
filter in the follow way once six months.
1 Remove the air cleaning filter.
2 Clean with water and dry in the air.
1) Flush the filter with fresh or warm water. Please
flush with diluted neutral detergent when extremely
dirty.
Never wash by reaming or rubbing, otherwise it
will damage the deodorizing effect.
2) Rinse with water flow.
3) Dry in shade.
3 Reinstall the air cleaning filter.
En-14
TROUBLESHOOTING
WARNING!
In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical breaker and consult authorized service personnel.
Merely turning off the unit’s power switch will not completely disconnect the unit from the power
source. Always be sure to turn off the electrical breaker to ensure that power is completely off.
Before requesting service, perform the following checks:
Symptom
NORMAL
FUNCTION
Doesn’t operate
immediately:
Noise is heard:
Smells:
Mist or steam is
emitted:
Airflow is weak or stops:
Water is produced from
the outdoor unit:
En-15
Problem
See Page
● If the indoor unit is stopped and then immediately started again,
the compressor will not operate for about 3 minutes, in order to
prevent fuse blowouts.
● Whenever the electrical breaker is turned off then on again the
protection circuit will operate for about 3 minutes, preventing unit
operation during that period.
—
● During operation or immediately after stopping the unit, the sound
of water flowing in the air conditioner’s piping may be heard.
Also, noise may be particularly noticeable for about 2 to 3 minutes after starting operation (sound of refrigerant flowing).
● During operation, a slight squeaking sound may be heard. This is
the result of minute expansion and contraction of the front panel
due to temperature changes.
—
● During Heating operation, a sizzling sound may be heard occasional.
This sound is produced by the Automatic Defrosting operation.
16
● Some smell may be emitted from the indoor unit. This smell is
the result of room smells (furniture, tobacco, etc.) which have
been taken into the indoor unit.
—
● During Cooling or Dry operation, a thin mist may be seen emitted
from the indoor unit. This results from the sudden Cooling of
room air by the cool air emitted from the indoor unit, resulting in
condensation and misting.
—
● During Heating operation, the outdoor unit’s fan may stop, and
steam may be seen rising from the unit. This is due to Automatic
Defrosting operation.
16
● When Heating operation is started, fan speed is temporarily very
low, to allow internal parts to warm up.
● During Heating operation, if the room temperature rises above
the thermostat setting, the outdoor unit will stop, and the indoor
unit will operate at very low fan speed. If you wish to warm the
room further, set the thermostat for a higher setting.
—
● During Heating operation, the indoor unit will temporarily stop
operation (between 7 and 15 minutes) as the Automatic Defrosting mode operates. During Automatic Defrosting operation, the
OPERATION Indicator Lamp will flash, and the DEFROST Indicator Lamp will light.
16
● During Dry mode, the indoor unit will operate at low speed; in
order to adjust room humidity, the indoor unit’s fan may stop
from time to time. Also, the fan may operate at very low speed
when adjusting room humidity.
7
● During SUPER QUIET operation, the fan will operate at very low speed.
6
● In the monitor of AUTO operation, the fan will operate at very
low speed.
7
● In case of Multi-type unit, if multiple units are operated in different operation modes as shown below, the units operated afterward will stop and the OPERATION indicator lamp will flash.
Heating mode and cooling mode (or dry mode)
Heating mode and fan mode
17
● During Heating operation, water may be produced from the outdoor unit due to Automatic Defrosting operation.
16
TROUBLESHOOTING
Items to check
Symptom
CHECK ONCE
MORE
Doesn’t operate at all:
See Page
● Has the circuit breaker been turn off?
● Has there been a power failure?
—
● Has a fuse blown out, or a circuit breaker been tripped?
● Is the timer operating?
Poor Cooling (or Heating)
performance:
8-9
● Is the Air Filter dirty?
● Air the air conditioner’s intake grille or outlet port blocked?
● Did you adjust the room temperature settings (thermostat)
correctly?
● Is there a window or door open?
—
● In the case of Cooling operation, is a window allowing bright sunlight to enter? (Close the curtains.)
● In the case of Cooling operation, are there heating apparatus and
computers inside the room, or are there too many people in the
room?
● Is the unit set for QUIET operation?
The unit operates
differently from the Remote
Controller’s setting:
6
● Are the Remote Controller’s batteries dead?
● Are the Remote Controller’s batteries loaded properly?
5
If the problem persists after performing these checks, or if you notice burning smells, or the OPERATION Indicator Lamp
(Fig. 3 5) and the TIMER Indicator Lamp (Fig. 3 6) flashes, immediately stop operation, turn off the electrical breaker and
consult authorized service personnel.
OPERATING TIPS
Operation and Performance
Heating Performance
● This air conditioner operates on the heat-pump principle,
absorbing heat from outdoor air and transferring that heat
to indoor unit. As a result, the operating performance is
reduced as outdoor air temperature drops. If you feel that
insufficient heating performance is being produced, we
recommend you use this air conditioner in conjunction
with another kind of heating appliance.
● Heat-pump air conditioners heat your entire room by
recirculating air throughout the room, with the result that
some time may be required after first starting the air conditioner until the room is heated.
Microcomputer-controlled Automatic Defrosting
● When using the Heating mode under conditions of low
outdoor temperature and high humidity, frost may form
on the outdoor unit, resulting in reduced operating
performance.
In order to prevent this kind of reduced performance, this
air conditioner is equipped with a Microcomputercontrolled Automatic Defrosting function. If frost forms,
the air conditioner will temporarily stop, and the
defrosting circuit will operate briefly (for about 7-15 minutes).
During Automatic Defrosting operation, the OPERATION
Indicator Lamp will flash, and the DEFROST Indicator
Lamp will light.
● After heating operation stops, if frost forms on the outdoor unit, the unit will start Automatic Defrosting
operation. At this time, the outdoor unit will automatically stop after operating for a few minutes.
(However, some type of multi-type air conditioner doesn't
provide this function.)
En-16
OPERATING TIPS
AUTO Restart
In Event of Power Interruption
● The power supply to the air conditioner is stopped by a
power interruption. The air conditioner will then restart
automatically in its previous mode when the power is
restored.
● If a power interruption occurs during TIMER operation, the
timer will be reset and the indoor unit will begin (or stop)
operation at the new time setting. In the event that this kind
of timer fault occurs, the TIMER Indicator Lamp will flash
(see Page. 3).
● Use of other electrical appliances (electric shaver, etc.) or
nearby use of a wireless radio transmitter may cause the
air conditioner to malfunction. In this event, temporarily
turn off the circuit breaker, turn it on and then use the
Remote Controller to resume operation.
Multi-type Air conditioner
This indoor unit can be connected to a multi-type outdoor unit. The multi-type air conditioner allows multiple indoor units to
be operated in multiple locations. The indoor units may be operated simultaneously, in accordance with their respective
output.
Simultaneous Use of Multiple Units
● When using a multi-type air conditioner, the multiple
indoor units can be operated simultaneously, but when
two or more indoor units of the same group are operated simultaneously, the heating and cooling efficiency
will be less than when a single indoor unit is used alone.
Accordingly, when you wish to use more than one indoor unit for cooling at the same time, the use should
be concentrated at night and other times when less output is required. In the same way, when multiple units
are used simultaneously for heating, it is recommended
that they be used in conjunction with other auxiliary
space heaters, as required.
● Seasonal and outdoor temperature conditions, the structure of the rooms and the number of persons present
may also result in differences of operating efficiency.
We recommend that you try various operating patterns
in order to confirm the level of heating and cooling output provided by your units, and use the units in the way
that best matches your family’s lifestyle.
● If you discover that one or more units delivers a low
level of cooling or heating during simultaneous
operation, we recommend that you stop simultaneous
operation of the multiple units.
● Operation can be done in the following different operating modes.
Cooling mode and dry mode
Cooling mode and fan mode
Dry mode and fan mode
● The operating mode (heating mode or cooling (dry)
mode) of the outdoor unit will be determined by the operating mode of the indoor unit that was operated first.
If the indoor unit was started in fan mode, the operating
mode of the outdoor unit will not be determined.
For example, if indoor unit (A) was started in fan mode
and then indoor unit (B) was then operated in heating
mode, indoor unit (A) would temporarily start operation in fan mode but when indoor unit (B) started operating in heating mode, the OPERATION indicator lamp
(green) for indoor unit (A) would begin to flash (1 second on, 1 second off) and it would go into standby mode.
Indoor unit (B) would continue to operate in heating
mode.
● Operation cannot be done in the following different operating modes.
If the indoor unit is instructed to do an operating mode
that it cannot perform, the OPERATION indicator lamp
(green) on the indoor unit will flash (1 second on, 1 second off) and the unit will go into the standby mode.
Heating mode and cooling mode (or dry mode)
Heating mode and fan mode
Notice
● During use of the heating mode, the outdoor unit will
occasionally commence the defrost operation for brief
periods. During the defrosting operation, if the user sets
the indoor unit for heating again, the defrosting mode
will continue, and the heating operation will begin after
completion of defrosting, with the result that some time
may be required before warm air is emitted.
En-17
● During use of the heating mode, the top of the indoor
unit may become warm, but this is due to the fact that
coolant is circulated through the indoor unit even when
it is stopped; it is not a malfunction.
Download PDF
Similar pages
CAD oper manual GB
Owners Manual
LG Electronics LP0711WNR Installation Guide
Samsung FC18BTVA User Manual
Samsung DC18BTSA User Manual
OM CN FIX RPM 1-N.1 GB 468100326
Samsung AQ13MSD User Manual
POOL conditioner instructions