Fire & Security
2-Wire Fire Alarms, Kits, Units & Accessories 81 - 83
Access Control 87, 92 - 93
Access Control Keypads & Kits 94
Conventional Fire Systems 84 - 86
Digital CCTV Systems 90
Door Entry 91
Fire Protection Covers/Gaskets 80
Intruder Alarms - Wired 88 - 89
Smoke/Heat/CO Alarms 78 - 79
Wireguards 95
Battery Powered Smoke/Heat/CO Alarms
Where to Use Smoke and Heat Alarms
Smoke alarm selection guide:
A domestic property requires 3 types of alarm to be fully protected.
• Heat alarms in kitchen.
• Optical alarms in landing and living spaces.
• Ionisation alarms in bedrooms.
Key
• Heat.
• Ion.
• Optical.
Bedroom 2
Bedroom 1
Kitchen
Dining
Benefits of different types of alarm
Landing
Bedroom 3
Hall
Slow Burning,
Smouldering
Fires
Lounge
Heat Alarms
Ionisation Alarms
Optical Alarms
Fast
Flaming
Fires
Resistant
to Kitchen
Fumes
✔
Heat Build
Up From
Large Fires
✔
✔
✔
Battery Powered Alarms
This comprehensive range of battery powered smoke alarms comes with a 9V battery, offering the most cost effective means of fire protection.
All models benefit from:
• Low battery warning signal - bleeps every 30 seconds
for 30 days when replacement battery is required.
• Automatic Self-Test - unit tests itself every 40 seconds
and bleeps if a fault is detected.
• Built in Test button - tests circuitry, sensor and
sounds horn.
• Interconnectable - up to 12 alarms can be
interconnected using lightweight twin core cable.
Heat Alarm
Optical Alarm
5 YR
Order Code
1050132583
Description
Battery Powered Heat Alarm
• Automatic reset facility - alarm automatically
resets itself once smoke has cleared from the
detection chamber.
Ionisation Alarm
5 YR
Order Code
1050132554
Description
5 YR
Order Code
Battery Powered Optical Alarm
1050132556
Description
Battery Powered Ionisation Alarm
Battery Powered CO Alarm
Carbon monoxide (CO) is a poisonous, colourless, odourless, tasteless gas and invisible to all the human senses. It can be lethal at both high and low levels of exposure.
It is now compulsory for ALL private sector landlords in England to install working carbon monoxide alarms or face a £5,000 fine.
Our CO alarms come with AudioLINK as standard. Simply download the AudioLINK app to your compatible smartphone or tablet to get access to extra data such as
CO activations, age (run time) and peak CO levels amongst other available data.
• 10 year ‘Powered for life’ sealed lithium battery.
• Test/Hush button - can either silence false alarms or
perform a self-test.
• Pre alarm gives early warning of CO.
5 YR
Order Code
1051034366
78
|
Description
Battery Powered CO Alarm
• Power, alarm and fault indicator lights for complete
peace of mind.
• End of life indication - notifies the user when the
alarm needs replacing at the end of its ten year
operational life.
Mains Powered Smoke/Heat/CO Alarms
Mains Wired Alarms with Battery Back-Up
This comprehensive range of hard-wired smoke alarms comes with a 9V battery back-up, ensuring that if a mains power failure occurs, the alarm will continue to operate in the
event of a fire. All models benefit from:
• 9V alkaline battery back-up - battery lasts for up to 4 years in standby mode and can
power the alarm for up to 2 years without mains power.
• Easi-fit base for fast installation - automatically connects both mains power and the
battery as the detector slides on.
• Test/Silence button - Can either silence false alarms or perform a self-test.
Heat Alarm
• Interconnectable - up to 20 alarms can be wirelessly interconnected when used with
RF mounting base - 1050352308.
• Low battery warning signal - bleeps every 40 seconds to indicate that the battery
back-up is depleted and needs replacing.
Optical Alarm
5 YR
5 YR
Order Code
Description
Order Code
Description
1000003700
Mains Wired Heat Alarm
1050132590
Mains Wired Optical Alarm
Ionisation Alarm
RF Mounting Base
5 YR
5 YR
Order Code
Description
Order Code
Description
1000003561
Mains Wired Ionisation Alarm
1050352308
RF Mounting Base
Mains Wired CO Alarm with Battery Back-up
Carbon monoxide (CO) is a poisonous, colourless, odourless, tasteless gas and invisible to all the human senses. It can be lethal at both high and low levels of exposure.
It is now compulsory for ALL private sector landlords in England to install working carbon monoxide alarms or face a £5,000 fine.
Our CO alarms come with AudioLINK as standard. Simply download the AudioLINK app to you compatible smartphone or tablet to get access to extra data such as CO
activations, age (run time) and peak CO levels amongst other available data.
• 10 year tamper proof rechargeable lithium battery back-up.
• Test/Hush button - Can either silence false alarms or perform a self-test.
• Easi-fit base for fast installation - automatically connects both mains power and the
battery as the detector slides on.
• Pre-Alarm gives early warning of CO.
• Power, alarm and fault indicator lights for complete peace of mind.
5 YR
Order Code
Description
1050360837
Mains Wired CO Alarm with Battery Back-up
Fire & Security |
79
Fire Protection Covers/Gaskets
• The fitting of recessed light fittings, wall sockets, light switches and
trunking for cables and other services can seriously compromise the
fire integrity of fire rated ceilings, floors and walls.
• The IEE Wiring Regulations, 17th Edition and Building Regulations
require the sealing of any penetrations of fire resistant elements in
walls, floors and ceilings to ensure that the original fire resistance of
the construction is maintained.
• Newlec fire protection covers can be used for ALL lamp types.
• Newlec fire protection covers for downlighters ensure an ONGOING
AND COMPLETE level of intumescent fire protection even if fittings are
replaced (i.e. by the homeowner).
Fire Protection Covers - Downlighters
NLFPC1
• In excess of 60 minute fire protection for the
ceiling.
• Easy to fit from above or below the ceiling.
• Fully intumescent, lightweight construction.
• Reduces noise transmission to the area above.
• Fully ventilated to avoid overheating of the
fitting.
• No maintenance required and unaffected by
moisture.
• Tested and approved to BS 476: Pt 20-23
BS EN1365-2.
Order Code Model No.
1050153474
NLFPC1
Internal Size
(mm)
Cut Out
(mm)
Pack
Qty
150 x 150
50 - 75
1
Fire Protection Covers - Fluorescent
NLFPC50
• In excess of 60 minute fire protection for the
ceiling.
• Easy to fit from above or below the ceiling with sufficient void space above.
• Lightweight construction - no supports or
fixing clips required.
• Reduces noise transmission to the area above.
• Easy access for maintenance of luminaire.
• No maintenance required and unaffected by
moisture.
• Tested and approved to BS 476: Pt 23 - 73mins.
Order Code Model No.
Internal
Size (mm)
1051005659
600 x 600
NLFPC50
Fire Protection Pillows
NLFPC38
Trunking pillows are used to seal off service
penetrations by simply choosing the size of
pillow required.
• The pillows should be tightly packed to
ensure a good seal. Where large holes are to
be filled, it may be necessary to use multiple
pillows to achieve a good seal.
• Tested & approved to BS476-20, BS476-22
and EN13633-3.
Order Code Model No.
Type
Internal Size
(mm)
1050153489
1050153490
1050153491
Pillow
Pillow
Pillow
300 x 50 x 40
300 x 150 x 40
300 x 200 x 40
Type
Size
(mm)
1 Gang Metal Box
2 Gang Metal Box
68 x 68
136 x 68
NLFPC38
NLFPC39
NLFPC40
Fire Protection Gaskets
• The appropriate gasket is simply placed into
position within the switch/socket box. In
the event of a fire the gasket expands and
prevents flames and smoke spreading further.
• Tested and approved to BS476-22.
80
|
Order Code Model No.
1050153481
1050153482
NLFPC30
NLFPC31
2-Wire Fire Alarms
How does a 2-wire fire alarm system work?
2 wire systems combine both the detection and the alarm annunciation wiring into a single circuit which allows the whole system to be easily
installed using only one pair of wires per zone. This compares to conventional alarm panels which require detection and alarm annunciation
on separate circuits therefore requiring 2 pairs of wires per zone.
Benefits of using the Newlec Twinflex Fire Alarm System:
Time Saving
Cost Saving
• Only one circuit per zone to
connect detectors and sounders
is required.
Multifunction Detection
Technology
Ease of Installation
• One pair of wires means decreased
cabling costs.
• Multi-function detectors and only
one pair of wires per zone makes
installation much simpler.
• The multipoint detectors have an
option for one of seven detection
modes settable on installation as well
as an integral sounder, saving money
and time whilst simplifying installation.
THIS ALL ADDS UP TO INSTALLATION SAVINGS UP TO 40% COMPARED TO AN
EQUIVALENT CONVENTIONAL SYSTEM
Twinflex Fire Alarm Panel
The Twinflexpro control panel is fully BS5839 and EN54 part 2 & 4 compliant and offers a complete solution for your fire alarm system - all on just two wires. It is available
in 2, 4 or 8 zone options and can accomodate up to 32 devices per zone.
• Key or code access for control user functions.
• Break glass identification on panel - differentiates between call point or detector alarm.
• 3.4Ah battery capacity - up to 12 hour standby.
• Control panel warning for head contamination indication to signal that optical chamber is
contaminated - reduces risk of nuisance alarms.
Order Code
Model No.
1051050503
1051050504
1051050505
NL2W2Z
NL2W4Z
NL2W8Z
Description
2 Zone Twinflex Panel
4 Zone Twinflex Panel
8 Zone Twinflex Panel
NL2W8Z
Multipoint Detectors
Newlec Multipoint ASD detectors use patented, advanced optical scatter sensor design and sophisticated electronic technology to deliver reliable smoke and/or heat detection,
significantly reducing the risk of nuisance fire alarms. They offer a full range of detection capabilities with an integrated sounder all from one device. They can be matched to any
environment in which they are installed and changed any time during the lifetime of the installation.
The Newlec multipoint ASD detector can be set with any of the following 7 modes of detection:
SMOKE 1
HEAT 1
Used where ionisation detectors are normally fitted
- especially when there are high ceilings or a risk of
free burning fires (chemical stores etc), or fires that
need to be detected extremely quickly.
Used where a standard rate-of-rise detector would
normally be used.
SMOKE 2
Standard fixed temperature heat detector (approx.
58°C) - Suitable for domestic kitchens etc.
SMOKE 3
HEAT 3
Designed for areas prone to nuisance alarms - has a
reduced sensitivity and time delay feature. Ideal for
hotel bedrooms with en-suite showers for example.
Model No.
1051057747
1051057748
1051050508
NLASD
NLASDS
NLMDSS
A combination of SMOKE 2 and HEAT 2 - will trigger
with either a smoke or a heat source.
HEAT 2
Used where optical detectors are normally fitted,
when there is a risk of a smouldering fire and for
escape routes.
Order Code
SMOKE 2 / HEAT 2
High fixed temperature (approx. 90°C) - suitable for
boiler rooms, commercial kitchens etc.
NLASD
Description
ASD Detector
ASD Detector with Sounder
ASD Detector with Sounder/Strobe
Fire & Security |
81
2-Wire Fire Alarm Kits & Accessories
Twinflex Starter Kits
Kit contains:
- 1 x 2, 4 or 8 zone panel (NL2W2Z, NL2W4Z or NL2W8Z).
- 6 x multipoint detectors with sounder (NLMDS).
- 1 x multipoint detector with sounder and strobe (NLMDSS).
- 2 x manual call points (NL2WCP).
- 1 x head removal tool.
NL2W22ZKIT
Order Code
Model No.
Description
1051050510
1051050511
1051050512
NL2W2ZKIT
NL2W4ZKIT
NL2W8ZKIT
2 Wire 2 Zone Kit
2 Wire 4 Zone Kit
2 Wire 8 Zone Kit
Twinflex Repeater Panel
• LCD display to indicate fire and fault events.
• Key switch operation.
• Can perform system controls over the network (ie silence alarms, reset sound alarms
and silence buzzer.
• Up to 8 repeater panels can be connected to a single control panel.
NLREPEAT
Order Code
Model No.
Description
1051050509
NLREPEAT
Repeater Panel
2-Wire Input/Output Unit
• Complies with EN54 Part 18.
• Provides an interface between ancillary devices and the zone.
• Can be installed on the same zone as the multipoint detector/sounder.
• Mounted in a standard double gang box.
• Comes with two sets of 2A rated SPCO relay contacts, one monitored input and
inbuilt ‘End of Line’.
Order Code
Model No.
1051050518
NL2WIO
Description
NL2WIO
ELECTRIC
RADIATORS
SEE PAGE 269
82
|
Input / Output Unit
Offering total
control room by
room with built-in
daily/weekly
programmer
2-Wire Fire Alarm Accessories
2-Wire Callpoints
• Complies with EN54 Part 11.
• Easy to install - just one screw connects the whole unit.
• Resettable element - need for replacement glass is negated,
simply reset using key provided.
• LED for indication of end of line and alarm.
• Adaptor plate provided for use with standard flush or surface back boxes.
Order Code
Model No.
1051050513
NL2WCP
Description
Manual Call Point
NL2WCP
2-Wire Sounder - Red
• Complies with EN54 Part 3.
• Use where extra sound output is required or where automatic detection is not needed.
• Bayonet locking system - makes sounder easy to install.
• Anti-tamper mechanism.
• Sounder volume - 90dB+.
Order Code
Model No.
Description
1051050515
NL2WSOUND
Sounder - Red
NL2WSOUND
Indoor/Outdoor Hi Point Sounder
• Complies with EN54 Part 3.
• IP55 rating making it suitable for external applications.
• Ideal for areas that do not require automatic detection but require a high sound level.
• Easy installation - base can installed at first fix and simply plugging in the unit when
required.
• Sounder volume - 65dB+ normal, 90dB+ high.
Order Code
Model No.
1051050516
NL2WSOD
Description
Outdoor Hi Point Sounder - Red
NL2WSOD
2-Wire Sounder/Strobe
• Complies with EN54 Part 3.
• Allows simple and effective visual indication plus sounder.
• Easy installation - base can installed at first fix and simply plugging in the unit
when required.
• Anti-tamper mechanism.
Order Code
Model No.
1051050517
NL2WSS
Description
NL2WSS
Sounder with Strobe
Fire & Security |
83
Conventional Fire Systems
Ancillary devices in the Newlec range have been specifically designed to be fully compatible with the Newlec range of
alarm panels.
All products are manufactured in an ISO 9001 facility and approved to EN54 parts 2 & 4.
Typical Wiring - Conventional System
Conventional
Fire Systems
Conventional - The Basics
• The philosophy of a conventional system revolves
around dividing the building into a number of areas
called zones. The detectors and callpoints within
each zone are then wired on dedicated zone
circuit.
• In the event of a detector or callpoint being
triggered, the panel is able to identify which
circuit contains the triggered device and thereby
indicate which zone the fire alarm has come from.
• It is then necessary to manually search the
indicated zone to pinpoint the exact cause of the
fire alarm.
• Because most conventional detectors are simple
two state devices they can only be in either a
normal or fire condition. Although modern
components and good system design can go
some way to reducing potential problems.
• Alarm devices such as electronic sounders or visual alarms
are wired on separate sounder circuits. It is important
that at least two sounder circuits are wired on each system.
Conventional Panel - 2, 4 and 8 Zone
The new conventional panel from Newlec fully complies with updated EN54 parts 2
& 4 legislation. It has everything necessary for the correct operation of the system,
including batteries and end of line monitors.
84
|
Order Code
Model No.
Panel
Type
1051050497
1051050498
1051050499
NLCFP2Z
NLCFP4Z
NLCFP8Z
2 Zone
4 Zone
8 Zone
Conventional Fire Systems
Detectors
Order Code Model No.
1050317817
1050317819
1050317820
1050317822
NLCDO
NLCDFH
NLCDRR
NLCDHT
Description
Optical Detector
77˚C Fixed
60˚C Rate of Rise
90˚C High Temperature
• Drift compensation.
• Ultra low profile, 360˚ viewing angle LED.
• Photo/Thermal alternative to old ionisation
types.
• Simple to install via a purpose designed
common mounting base.
1 YR
NLCDO
Detector Base
Order Code Model No.
Description
1050317821
Common Base
NLCDB
• Selectable detector locking feature.
• Separate zone in and out connections.
• Base incorporates features to support surface
wiring.
1 YR
NLCDB
Remote Indicator
Order Code Model No.
1050317823
NLCDRI
Description
Remote Indicator
• Simple to install, fits onto standard single
gang back box.
1 YR
NLCDRI
Call Points
Order Code Model No.
1050317800
1050317803
1050317804
NLCSMCP
NLCRBG
NLCCPK
Description
Callpoint, Service/Flush
Break Glasses (pack of 5)
Callpoint Keys (pack of 10)
• Fast fit clip on front cover, for ease of
installation and maintenance.
• Heavy duty terminals.
• A bottom entry facility is included for simple
testing in confined locations.
1 YR
NLCSMCP
Bell
Order Code Model No.
1050317811
NLCB
Description
6 Inch Bell, 24V DC
• High sound output.
• Low current consumption.
• Class change facility.
1 YR
NLCB
Surface Sounder
Order Code Model No.
Description
1050317805
Surface Sounder
NLCLPS
• Quick and simple to install.
• Low profile design.
• 32 selectable tones.
1 YR
NLCLPS
Fire & Security |
85
Conventional Fire Systems
Sounder Base
NLCBS
• May be fitted with integrated detector
mounting base.
• Optional cover plate.
• Can be used as a base sounder or stand
alone sounder.
.
Order Code Model No.
Description
1050317807
Sounder Base
NLCBS
1 YR
Magnetic Door Holders
• Supplied with striker plate.
• Floor or wall mounting.
1 YR
NLDR240
Order Code Model No.
1050317812
1050317813
1050317816
1050392659
NLDR240
NLDRDC
NLDRB
NLMDR
Description
Magnetic Door Release 240V
Magnetic Door Release 24V DC
Floor Mounted Bracket
Magnetic Door Release 1.5 Amp PSU
Visual Alarm Devices (VADS)
NLVADSWB
2014 saw the introduction of EN54-23, a new standard for fire alarm beacons. The
update to BS5839-1 2013 requires EN54-23 approved beacons as part of the risk
assessment, especially important for high noise areas, lone working environments
or where there is an expectation of occupants with hearing difficulties. The new
range from Newlec for conventional panels ensures you compliant to the latest
standards and comprises of:
- Deep base wall beacon - Red
- Ceiling beacon - White.
- Wall Sounder beacon - Red.
Suitable for when a visual alarm device is required in addition to an audible alarm.
• 7.5M room coverage.
• Current consumption as low as 10mA.
• 0.5Hz or 1.0Hz flash rate.
• Red flash.
• 4 power settings.
86
|
NLVADSCB
Order Code Model No.
1051050500
1051050501
1051050502
NLVADSWB
NLVADSCB
NLVADSSB
NLVADSSB
Description
Red Wall Beacon
White Ceiling Beacon
Red Sounder Beacon
Access Control
Emergency Assist Alarm Kit
There are a variety of regulations covering the provision of disabled facilities and disabled access within a building which can make knowing which emergency assist alarm to
install seem complicated. Easy to install, stand alone emergency alarm kit from Newlec makes product selection straight forward and complies with all the relevant elements of
the regulations listed below:
• Building Regulations Approved Doc M.
• BS8300:2009 - replaces BS8300:2001.
NLEAA
• Quick and simple to install - limited cable requirements.
• High output blue LED indicator and buzzer provide visual and audible feedback
that alarm has been operated.
• High contrast printing for increased visibility.
• Tactile braille signage on cancel button to assist partially sighted.
Ceiling unit
with pullcord
Overdoor
indicator
Kit contains:
1 x Power supply unit.
1 x Over door indicator.
1 x Ceiling unit with red dual loop pull cord.
1 x Clearly labelled “Cancel” button.
1 x Disabled sticker.
Power
supply
Cancel
button
Order Code Model No.
1052055662
NLEAA
MEV
Description
Disabled Toilet Alarm Kit
MECHANICAL
EXTRACT
VENTILATION
Simultaneous ventilation
of separate wet areas,
kitchens and utility
rooms
SEE PAGE 255
Fire & Security |
87
Intruder Alarms - Wired
Intruder Alarms - Wired
Newlec have your security in mind
Every home deserves the protection of a dependable alarm system. The Newlec range of security panels offers the perfect solution for both residential and light commercial applications.
The extensive range of products provides the professional installer with a comprehensive and reliable solution, that can be fitted with ease and with minimum disruption to a property.
Alarm Kit - 8 Zone LED
NL2100
• 8 zone wired control panel.
• LED remote keypad.
• 4 x 12M motion sensors.
• Bell box.
• Surface mount contacts.
• Panic button.
• 100M 6 core cable.
• 12V/1.2 AH battery.
Order Code Model No.
Description
1050362905
8 Zone LED Kit
NL2100
1 YR
Alarm Kit - 8 Zone LCD
NL2101
• 8 zone wired control panel.
• LCD remote keypad.
• 2 x 12M motion sensors.
• Bell box.
• Surface mount contacts.
• Panic button.
• 100M 6 core cable.
• 12V/1.2 AH battery.
Order Code Model No.
Description
1050362906
8 Zone LCD Kit
NL2101
1 YR
Alarm Panel - Wired 8 Zone
• Up to 4 keypads per panel.
• 3 part set programmes.
• 2 zones can be programmed as fire.
• 4 access codes.
1 YR
Order Code Model No.
1050363495
1050363496
NL2115
NL2116
Description
LED Panel
LCD Panel
NL2115
Speech Dialler
• Dedicated speech dialler - inhibit for bells
only panels.
• Follow me number (+ 3 dedicated).
• 3 warning messages.
• Adjustable playback volume.
• 4 trigger inputs.
Order Code Model No.
Description
1050362908
Speech Dialler
NL2103
1 YR
NL2103
Remote Keypads
NL2107
• LED keypad can be used with NL2100 or
NL2115.
• LCD keypad can be used with NL2101 or
NL2116.
• Remote keypads can be mixed.
• Up to 4 keypads per panel.
1 YR
88
|
Order Code Model No.
1050362912
1050363497
NL2107
NL2117
Description
LED Keypad
LCD Keypad
Intruder Alarms - Wired
PIR
Order Code Model No.
1050362910
NL2105
Description
PIR
• Passive infrared motion sensor with
temperature compensation.
• Look-down zone.
• Insect trap built in.
• Tamper switch.
NL2105
1 YR
Detector
Order Code Model No.
1050362913
NL2108
Description
Detector
• 15M x 18M range dual technology detector.
• Ability to adjust the microwave down to suit
the characteristics of a 3M room.
• K-band technology, 35mA @ 12V DC.
• Operating temperature -10°C to 55°C.
• Ideal for garages & conservatories.
• EN50131-1 Security Grade 2.
NL2108
1 YR
Bell Box
Order Code Model No.
Description
1050362909
Wired Bell Box
NL2104
• ActiveGuard external siren.
• Sound output of 110dB.
• One standard, built-in, wrap around
strobe lens.
• Horizontal and vertical mounting.
• Multi-colour options.
NL2104
1 YR
Magnetic Contacts
Order Code Model No.
1050362915
NL2110
Description
Surface
• 4 wire magnetic contact including tamper
loop.
• Surface mount, 5 screw terminals.
• Recessed magnetic contact including
tamper loop.
• EN50131-1 Security Grade 2.
• Environmental Class II.
NL2110
NL2111
1 YR
Intruder Alarm Cable
Order Code Model No.
1000008722
1000008723
1000008724
NL308N
NL309N
NL329N
No.
Cores
4
6
8
• 7 x 0.19mm stranded tinned, annealed, copper
conductor - nominal.
• Integral rip cord.
• Increased flexibility.
• Double tested during manufacture to resolve
false alarm triggering when installed.
• 100M coil.
NL308N
1 YR
4 core - Red, blue, yellow, black.
6 core - Red, blue, yellow,
black, white, green.
8 core - Red, blue, yellow, black,
white, green, orange, brown.
Fire & Security |
89
Digital CCTV Systems
Newlec offers a simple to install digital CCTV solution for home or business use with many benefits.
• High capacity digital video recorder.
• Images from video recorder can be viewed via a remote PC or 3G mobile device via
the internet.
• Cameras suitable for both internal and external use.
• Day/night cameras provide clear colour images during the day and crisp infra red
illuminated mono images at night.
• Image recording can be either be motion triggered or continuous running.
• Recordings can be easily transferred using the supplied USB stick.
Digital CCTV Kits
The Newlec digital CCTV kits contain everything you need to install either a four or
eight channel networkable CCTV system. Kits include:
NLDVRKIT4I
- 1 x 4 or 8 channel networkable DVR.
- 1 x 500GB western digital hard drive
(1Tb hard drive with NLDVRKIT8I).
- 4 x IRCAM40P day/night external cameras.
- 4 x 20M shotgun cables (cameras - DVR).
- 1 x 5 way power supply (cameras - DVR).
- 1 x Wi-fi networking USB adaptor (dongle).
Order Code Model No.
1052051481
1052051482
NLDVRKIT4I
NLDVRKIT8I
- 1 x USB mouse.
- 1 x Instruction manual.
- 1 x 2gB USB stick.
- 1 x remote control.
- 1 x 4 way power supply for additional
cameras (NLDVRKIT8I only).
Description
4 Channel Networkable CCTV System
8 Channel Networkable CCTV System
External Day/Night Camera
• 3.6mm fixed lens.
• Day / night CCTV camera c/w 15M
cable.
• Up to 8M Infra Red illumination.
• 12V DC 300mA (IR-on).
• Weatherproof IP65 rating.
NLCAM40
Order Code Model No.
1050378466
NLCAM40
Description
External Day/Night Camera
1 YR
External Day/Night Camera
• 6mm fixed lens.
• Up to 15M Infra Red illumination.
• 12V DC 350mA (IR-on).
• Weatherproof IP66 rating.
Order Code Model No.
1051040112
NLCAM200
Description
420 TVL Standard Camera
1 YR
NLCAM200
CCTV - Cables
• Power and BNC video cables for
use with Newlec digital CCTV
equipment.
• Available in 20, 40 and 80M lengths.
1 YR
Order Code Model No.
1050344075
1050344076
1050344077
NLCAB20
NLCAB40
NLCAB80
Description
20M Cable
40M Cable
80M Cable
NLCAB20
Additional accessories available on request, including a wide range of cameras, warning signs and camera power supply units. Please ask for details.
90
|
Door Entry
Door Entry Kit - One Way Audio
Order Code Model No.
1000009547
NLAK1W
Description
Surface Mounted One Way Audio Door Entry Kit
• Volume control for audio.
• Can be fitted with lock release either,
NLLRR1 (Rim) or NLLRM1 (Mortice).
• 3 additional phones can be added
(NLAKPHONE).
1 YR
NLAK1W
Door Entry Kit - One Way Audio And Codelock
Order Code Model No.
1050151473
NLAK1WCODE
Description
Surface Mounted One Way Audio
and Codelock Door Entry Kit
• Anodised aluminium 1 button entrance
panel with keypad (IP45).
• Keypad has 100 code facility.
• Volume control for audio.
• Can be fitted with lock release either,
NLLRR1 (Rim) or NLLRM1 (Mortice).
• 3 additional phones can be added.
(NLAKPHONE).
1 YR
NLAK1WCODE
Door Entry - Additional Handset
• For use with Newlec audio door entry kits.
• Manufactured in textured high impact ABS.
• Clear call tone.
Order Code Model No.
1000009117
NLAKPHONE
1 YR
NLAKPHONE
Video Door Entry Kits - One Way
Order Code Model No.
1052051495
NLEV5C
Description
Colour Video Door Entry Kit
• Provides crisp, colour images and clear
sound via 4" high resolution monitor.
• Weatherproof and vandal resistant
camera.
• Bright white LED illumination from the
camera aids identification in darkness.
• Door release activation button.
• Extra power supply NLLRPSU required
when using any system with an
electronic lock.
NLEV5C
Fire & Security |
91
Access Control
Electro Magnetic Locks
Electro magnetic locks offer the ideal solution to secure a door. They can be used in conjunction with an audio door entry system (NLAK range) or an electronic access control
system (NLLRK range).
• Suitable for timber and aluminium single leaf doors.
• Dual voltage - 12 or 24V DC.
• Push off button situated on armature plate for instant release.
• Current draw - 12V DC 500mA, 24V DC 250mA.
• Monitored and un-monitored versions available.
- Monitored - detects if door is open or closed as part of a wider security system.
- Un-monitored - does not detect if door is opened or closed.
Single Leaf Doors
Select Security Level
Medium Security
Slimline Magnets
Medium/High Security
Standard Magnets
Non-Monitored
Monitored
Non-Monitored
Monitored
Use NLLRMAGS1
Use NLLRMAGS2
Use NLLRMAGT1
Use NLLRMAGT2
Door Opening Direction
Door Opening Direction
Outward Opening
using L Bracket
Inward Opening using
Z & L Brackets
Outward Opening
using L Bracket
Inward Opening using
Z & L Brackets
L Bracket Use
NLLRMAGS4
Z and L Bracket Use
NLLRMAGS4
L Bracket Use
NLLRMAGT4
Z and L Bracket Use
NLLRMAGT4
Medium Security Slimline Magnets
Order Code Model No.
1050151474
1050151475
1050151477
NLLRMAGS1
NLLRMAGS2
NLLRMAGS4
Medium/High Security Standard Magnets
Description
Slimline Magnet
Slimline Magnet Monitored
Slimline Magnet Z & L Bracket
Order Code Model No.
1050151478
1050151479
1050151481
NLLRMAGT1
NLLRMAGT2
NLLRMAGT4
Description
Standard Magnet
Standard Magnet Monitored
Standard Magnet Z & L Bracket
Double leaf door electro magnetic available through branch network
Power Supply Unit
• Suitable for all access control products. • Battery back-up connection.
• 12V DC.
• Regulated outputs 1, 2 & 3 Amp.
Order Code Model No.
1000009561
1052051422
NLLRPSU
92
|
NLLRPSU
NL11620
Description
12V DC 1 Amp PSU
12V DC 2 Amp PSU
Access Control
Gate Electro Magnetic Lock
• Ideal for vehicle and pedestrian gates.
• Surface mounted and simple to install.
• Suitable for external use.
• Up to 1200lbs holding force.
• Reed switch monitoring.
• Weatherproof.
Order Code Model No.
Description
Dimensions
H x W x D (mm)
1052051414
1052051415
Gate Magnet
Z Fixing Bracket
222 x 63 x 40
Adjustable
NL11612
NL11613
NL11612
12V Electric Lock Releases
The new range of electric lock releases from Newlec come with both rim and mortice
faceplates to suit virtually any application and are ideal for low to medium traffic areas.
• Fail locked and fail unlocked.
• Rim releases suitable for rim nightlatches.
• Jaw strengths up to 880lbs.
• Operating voltage 12V.
• Suits latches with 12mm maximum throw.
Order Code Model No.
1051058525
1051058526
NLELR2
NLELR3
Description
Fail Locked Release 12V DC
Fail Unlocked Release 12V DC
Request To Exit Buttons
NLLRBSBV
NLLRBV
Order Code Model No.
1000009583
1050362746
1050362748
1051011301
NLLRBV
NLLRBGBV
NLLRBSBV
NLLRBPGB
NLLRBGBV
Description
Dimensions
H x W x D (mm)
Flush Stainless Steel Exit Button
Flush Stainless Green Dome Exit Button
Surface Mount Single Gang Exit Button
Surface Mount Green Dome Exit Button
85 x 85 x 30
85 x 85 x 30
85 x 85 x 30
85 x 85 x 30
NLLRBPGB
• Stainless steel and plastic options.
• Normally open and closed contacts.
• Flush or surface mounted.
• Will fit into single gang back box.
Resettable Call Points
• Easy to install.
• Recommended when installing an electro magnetic lock.
• Single and double call points available.
Order Code Model No.
1000009560
1050362749
NLLRBE
NLLRBEDP
Description
Resettable Call Point - Single Pole
Resettable Call Point - Double Pole
NLLRBE
NLLRBEDP
Fire & Security |
93
Access Control Keypads & Kits
IP68 Rated Keypad
The new Newlec keypad is heavy duty, vandal resistant and completely
waterproof making it suitable for any application.
• Pin access control and/or proximity reader when used with NLCARDS
(sold separately).
• 4-8 digit pin code length.
• IP68 rated for total protection against dust and water ingress.
• Back-lit keys for easy visibility in low lit areas.
• Strong zinc alloy electroplated case for protection against vandalism.
NLKP
Order Code Model No.
1051058527
1051058528
NLKP
NLCARDS
Description
Pin Access and/or Proximity Keypad
Access Cards for Proximity Keypad
Access Control Kits
Contents for Electro-magnetic lock kit:
• NLLRPSU - 12V DC 1 Amp Power Supply Unit.
• NLKP - Pin access and/or proximity keypad.
• NLLRMAGS1 - Slimline electro magnet.
• NLLRBSBV - Surface mount single gang exit button.
• NLLRBE - Resettable call point - single pole.
Electro-magnetic lock is suitable for outward opening doors - use bracket
NLLRMAGS4 for inward opening doors.
NLACKIT1
Order Code Model No.
1051058529
1051058528
VDE
TOOLS
SEE PAGES
302 - 305
94
|
NLACKIT1
NLCARDS
Description
Electro-Magnetic Lock Kit
Access Cards for Proximity Keypad
Get tooled up with
our VDE range
Wireguards
Wireguards
A wide range of specialist purpose built welded wireguards to protect any kind
of equipment from damage caused by vandalism, interference or accidents.
• Easy to fit.
• Choice of finish, electro galvanised to BS 1706 ZN3 or white powder coated.
• Other sizes available on request, any size, any style - contact local branch
and quote overall dimensions of guard required, allowing approximately
1" clearance around the component, finish required (galvanised or white
powder coated), quantity and application.
NLWG15
NLWG3
NLWG12
1 YR
Order Code
Model No.
Finish
Dimensions
(inches)
External Security Lighting Guards
1050151388
NLWG1
Galvanised
12 x 10 x 14
External Bulkhead Guard
1050151390
NLWG3
Galvanised
14 x 6 x 5
Bell Box Guard
1050151391
NLWG4
Galvanised
10 x 16 x 5
PIR Guards
1050151537
NLWG24
Galvanised
6 x 5 x 6 deep
Camera Guards
1050151536
NLWG23
1050151437
NLWG22
Galvanised
Galvanised
14 x 14 x 16 deep
7x6x8
Discharge Fitting Guards
1050150542
NLWG15
1050150543
NLWG16
Galvanised
Galvanised
14 x 14 x 16
18 x 18 x 18
Smoke Detector Guard
1050150545
NLWG18
Galvanised
7x7x4
White Powder Coated
22 x 36 x 8 Open Bottom
Size
Finish
Dimensions
(inches)
Fluorescent Batten Fitting Guards
1050151396
NLWG9
1050151398
NLWG11
1050151400
NLWG13
4
5
6
Galvanised Finish
Galvanised Finish
Galvanised Finish
49 x 6 x 5
61 x 6 x 5
73 x 6 x 5
Tubular Heater Guards
1050150546
NLWG19
1050150547
NLWG20
1050150548
NLWG21
2
4
6
Galvanised Finish
Galvanised Finish
Galvanised Finish
29 x 6 x 6
53 x 6 x 6
74 x 6 x 6
Convector Heater Guards
1050151539
NLWG26
Order Code
Model No.
Fire & Security |
95