PFM7##-TFK27-A
Safety Instructions (Continued)
Installation
Caution
Safety Instructions
This manual contains essential information for the protection of users
and others from possible injury and/or equipment damage.
•Read this manual before using the product, to ensure correct handling,
and read the manuals of related apparatus before use.
•Keep this manual in a safe place for future reference.
•These instructions indicate the level of potential hazard by label of
"Caution", "Warning" or "Danger", followed by important safety
information which must be carefully followed.
•To ensure safety of personnel and equipment the safety instructions in
this manual and the product catalogue must be observed, along with
other relevant safety practices.
Caution
CAUTION indicates a hazard with a low level of risk
which, if not avoided, could result in minor or
moderate injury.
Warning
WARNING indicates a hazard with a medium level
of risk which, if not avoided, could result in death or
serious injury.
Danger
•Do not touch the terminals and connectors while the power is on.
Otherwise electric shock, malfunction or damage to the product can result.
•After maintenance is complete, perform appropriate functional
inspections and leak tests.
Stop operation if the equipment does not function properly or there is a
leakage of fluid.
When leakage occurs from parts other than the piping, the product is
faulty.
Disconnect the power supply and stop the fluid supply.
Do not apply fluid under leaking conditions.
Safety cannot be assured in the case of unexpected malfunction.
Panel mounting
•Insert Panel Mount Adapter B (supplied as an accessory) into Section A of
Panel Mount Adapter A.
Push Panel Mount Adapter B from behind till the display is fixed onto the
panel.
The pin of Panel Mount Adapter B engages the notched part of Panel
Adapter C to fix the display.
•The switch can be mounted on a panel with a thickness of 1 to 3.2 mm.
•See the illustration below for panel cut out dimensions.
Section C
A
24 +0.5
0
Installation & Maintenance Manual
Digital Flow Switch
Series PFM7
Installation (Continued)
NOTE
•The direct current power supply to be used should be UL approved as
follows:
Circuit (class 2) which is of maximum 30 Vrms (42.4 V peak), with UL 1310
class 2 power supply unit or UL 1585 class 2 transformer.
•The Flow switch is a
approved product only if it has a
mark on
the body.
Section A
Insert
Panel Mount
Adapter A
Panel
Push
Appropriate torque Nm
7 to 9
12 to 14
Panel Mount
Adapter B
Bracket
Refer to the operation manual and the product catalogue for more detailed
information.
Without flow adjustment valve
With flow adjustment valve
Dimension A
54 +0.5
0
74 +0.5
0
Adapter
ZS-33-J
ZS-33-JS
•For one-touch fitting, insert the tube to the end so that it cannot be
pulled out.
•Insertion with excessive force can cause damage.
•Ensure there is no leakage after piping.
•Use this product within the specified operating pressure range and
operating temperature range.
•Withstand pressure is 1.0 MPa.
This product is class A equipment that is intended for use in an industrial
environment.
There may be potential difficulties in ensuring electromagnetic
compatibility in other environments due to conducted as well as radiated
disturbances.
•Do not disassemble, modify (including changing the printed circuit
board) or repair.
An injury or failure can result.
•Do not operate the product outside of the specifications.
Do not use for flammable or harmful fluids.
Fire, malfunction, or damage to the product can result.
Verify the specifications before use.
•Do not operate in an atmosphere containing flammable or
explosive gases.
Fire or an explosion can result.
This product is not designed to be explosion proof.
•Do not use the product in a place where static electricity is a
problem.
Otherwise it can cause failure or malfunction of the system.
•If using the product in an interlocking circuit:
•Provide a double interlocking system, for example a mechanical
system
•Check the product regularly for proper operation
Otherwise malfunction can result, causing an accident.
•The following instructions must be followed during maintenance:
•Turn off the power supply
•Stop the air supply, exhaust the residual pressure and verify that
the air is released before performing maintenance.
Otherwise an injury can be caused.
Nominal size of screws
Rc1/8
Rc1/4
Model Indication and How to Order
DANGER indicates a hazard with a high level of risk
which, if not avoided, will result in death or serious
injury.
Warning
Piping
•Ensure tightening torque is correct when installing piping.
•Refer to the following table for the appropriate torque values.
•Hold the metal part with a spanner when piping.
Names and Functions of Individual Parts
LED display
button
button
Output OUT2
Output OUT1
button
Flow adjustment valve
Knurl
Bracket mounting
•Fasten the bracket mounting screws to a torque of 0.5±0.05 Nm.
Without flow adjustment valve
(using ZS-33-M)
With flow adjustment valve
(using ZS-33-MS)
Self tapping
screws
Self tapping
screws
S
Piping port
Through hole
IN
Body
Output (OUT1) display (Green): Light is on when output OUT1 is on.
Flashes when overcurrent error occurs.
Output (OUT2) display (Red): Light is on when output OUT2 is on.
Flashes when overcurrent error occurs.
LED display panel: Displays flow value, set mode condition, and error code.
Indication colour is selectable from Red and Green
depending on output (OUT1) condition.
button (UP): Selects the mode and increases the mode or ON/OFF set
value. Press this button to change to the peak display
mode.
button (DOWN): Selects the mode and decreases the mode or ON/OFF
set value. Press this button to change to the bottom
display mode.
button (SET): Press this button to change to each mode and to select a
set value.
Reset: Press the
and
buttons simultaneously to start reset function.
This is to clear the condition when an abnormality occurs.
Body: Product itself.
Flow adjustment valve: Orifice mechanism to adjust the flow.
Piping port: Connection port for piping.
Knurl: Used to lock the flow adjustment valve.
Through hole: Used to mount the product on a DIN rail or a panel directly.
DIN rail mounting
•The tightening torque for DIN rail mounting screws and joint screws should
be 0.4±0.05 Nm.
Wiring
Connection
•Make connection after turning the power off.
•Use a separate route when installing wire. Malfunction stemming from
noise may occur if wire is installed in the same route as that of power or
high-voltage cable.
•Be sure to ground terminal FG when using a switching regulator
obtained on the market. If analogue output is performed connecting to a
switching regulator obtained on the market, switching noise will be
superimposed and product specification can no longer be met. This can
be prevented by inserting a noise filter, such as a line noise filter and a
ferrite element, between the switching regulator and the pressure
switch, or by using a series power supply instead of a switching
regulator.
Connector
Connecting/Disconnecting
•When connecting the connector, insert it straight onto the pin holding
the lever and connector body between fingers and lock the connector by
pushing the lever claw into the square groove in the body of the switch.
•When disconnecting the connector, push down the lever by thumb to
disengage the lever claw from the square groove. Then pull the
connector straight out.
Body of switch
Through hole
Bracket
Joint screw
DIN rail mounting
bracket
Note) DIN rail mounting is not suitable for
models with port type F02: G1/4.
DIN rail mounting
screw
Lever
Lead wire connector
Cover (Option: ZS-33-F)
PFM7##-TFK27-A
Setting
Setting (Continued)
Measurement mode
The measurement mode is the condition where the flow is detected and
indicated, and the switch function is operating.
This is the basic mode, other modes should be selected for set-point
and other function setting change.
Function setting (Continued)
3. Press the
or
button to change the set value.
The
button is to increase and the
button is to decrease the set
value.
•Press the
button once to increase by one digit, press and hold to
continuously increase.
Error Indication Function (Continued)
•[F 1] Operation of OUT1
Item
Error Name
Default setting
Explanation
Select output for instaneous flow
(hysteresis mode, window comparator
Hysteresis mode
mode) accumulated flow or
accumulated pulse
Output mode
Power is supplied
Reversed output To select reversed output
The unit specification is displayed
Approx.3 seconds
(the output remains off
for this period)
Approx.1 second
The product identification is displayed
•Press the
button once to decrease by one digit, press and hold to
continuously decrease.
Approx.1 second
The flowrange identification is displayed
Flow setting
To set ON point or OFF point of the
switch output
Medium value of
flow setting range
Hysteresis
Chattering can be prevented by
setting hysteresis
3%
ON: Green
OFF: Red
Approx.1 second
4. Press the
button to finish the setting.
If 2 outputs specification is selected, [P_2] is displayed.
Continue the setting operation.
Zero clear of indication
Indication is reset to zero when
and
buttons are pressed
simultaneously for 1 second.
For initial use, implementation of zero clear is recommended.
Set ON and OFF points of the Flow switch.
Switch operation
When a flow rate exceeds a setting point, the switch will be turned on.
When the flow rate falls below the setting point by hysteresis or more,
the switch will be turned off.
The switch is adjusted such that it will be turned on with the center point
of a flow rate setting range for each product specification.
If the operation shown below doesn't cause any problem, do not change
the settings.
Function setting
Measurement mode
Set value
P_1
Flow [L/min]
Press button for 2 sec. or longer
Function selection mode
Zero clear
error
●[F 2] Operation of OUT2
Same setting as [F 1] OUT1.
Display colour depends on the setting of OUT1.
Item
[F 3] Select operating fluid
[F 4] Display unit selection
[F 5] Setting of response time
[F 6] Select display mode
[F 7] External input
[F 8] Select display resolution
[F 9] Set auto pre-set
[F10] Hold accumulated value
[F11] Select analogue output filter
[F12] Select power saving mode
[F13] Set security code input
Error type
dry air-N2
Standard condition (ANR)
1 second
Instantaneous flow
Integrated value external reset
100-split
Manual
OFF
ON
OFF
OFF
Flow error
Troubleshooting
Condition is that of
before the adjustment at
factory. Internal circuit
ispossibly damaged.
Stop operation
immediately and
contact SMC Sales
office.
System error.
Failed to memorize the
data, or internal circuit is
possibly damaged.
Reset using reset
function.
If fluid flows during zero
clear setting (pressing
and
buttons
simultaneously for less
than 1 second), "Er4" is
indicated on the screen
for 1 second.
Please check that
fluid doesn't flow at
the time of zero clear
setting.
Default setting
Accumul Accumulated flow range
is exceeded.
ated
Flow
displayed
Clear the
accumulated flow.
(If accumulated flow
is not used, this is
not a problem.)
If the error can not be reset after the above measures are taken, then
please contact SMC.
Troubleshooting
Refer to the operation manual for this product.
Specification
Other Functions
Function selection mode
In measurement mode, press the
button for 2 seconds or longer to
display [F 1] ([F 0] is displayed for unit changeable type). Display [F□□], and
point the mode to change the setting of each function.
Press the
button for 2 seconds or longer at function selection mode to
return to measurement mode.
System
error
Normal output
Indication colour Select the display colour
Measurement mode
Error
Display
•Peak/Bottom hold value indication
•Zero clear
•key lock
Refer to the operation manual and the product catalogue for more
detailed information.
To set each function in detail, refer to the operation manual.
Outline with Dimensions (in mm)
Refer to the operation manual and the product catalogue for more
detailed information.
Maintenance
How to reset the product after power cut or de-energizing
The setting of the product will be retained as it was before a power cut or
de-energizing.
The output condition is also basically recovered to that before a power cut
or de-energizing, but may change depending on the operating environment.
Therefore, check the safety of the whole facility before operating the
product.
Switch ON
Switch OFF
Time [s]
<How to perform> *: The Product will also output during setting.
1. Press the
button once in the measurement mode.
2. [P_1] or [n_1] and the set value are displayed alternately.
Normal output
Reversed output
Displays in turn
Setting functions
Default setting
At the time of shipment, the settings are performed as follows.
If the setting is acceptable, keep it for use.
Caution for handling
When the setting is changed, since the different setting item appears in
order depending on how many times the button is pressed, confirm the
item which needs to be set appears to prevent undesired settings.
Contact
Error Indication Function
This function is to display error location and content when a problem or an
error has occured.
Error Name
Flow error
Overcurrent
error
Error
Display
Error type
Troubleshooting
Flow exceeds the upper
limit of the flow display
range.
Reduce the flow.
5% or more flow in the
reverse direction.
Direct the flow to the
proper direction.
Load current of the
switch output (OUT1)
exceeds 80 mA.
Load current of the
switch output (OUT2)
exceeds 80 mA.
Turn off the power
supply and eliminate
the cause of excess
current. Then supply
the power again.
AUSTRIA
BELGIUM
CZECH REP.
DENMARK
FINLAND
FRANCE
GERMANY
GREECE
HUNGARY
IRELAND
ITALY
(43) 2262 62280
(32) 3 355 1464
(420) 541 424 611
(45) 7025 2900
(358) 207 513513
(33) 1 6476 1000
(49) 6103 4020
(30) 210 271 7265
(36) 23 511 390
(353) 1 403 9000
(39) 02 92711
NETHERLANDS
NORWAY
POLAND
PORTUGAL
SLOVAKIA
SLOVENIA
SPAIN
SWEDEN
SWITZERLAND
UNITED KINGDOM
(31) 20 531 8888
(47) 67 12 90 20
(48) 22 211 9600
(351) 21 471 1880
(421) 2 444 56725
(386) 73 885 412
(34) 945 184 100
(46) 8 603 1200
(41) 52 396 3131
(44) 1908 563888
URL http://www.smcworld.com (Global) http://www.smceu.com (Europe)