309815R - Reactor Feed Pump Kits Instruction-Parts

Instructions - Parts
Feed Pump Kits
309815R
EN
Supply polyurethane materials from 55 gal. (200 liter) drums to Reactor™ Proportioner.
For professional use only.
Not for use explosive atmospheres.
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
See page 2 for a list of feed pump kits.
246655 Feed Pump Package
shown installed in Reactor proportioning system. Some parts
shown are not included in kit.
TI7690A
Feed Pump Kits
Contents
Feed Pump Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . .
Manual Conventions . . . . . . . . . . . . . . . . . . . . . . . .
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Husky 1050 Wall Mount . . . . . . . . . . . . . . . . . . .
Standard 2:1 Kit . . . . . . . . . . . . . . . . . . . . . . . . .
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Changing Drums . . . . . . . . . . . . . . . . . . . . . . . . .
2
3
3
5
8
8
9
9
9
9
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Complete Feed Pump Packages . . . . . . . . . . . . 10
Fluid Supply Kits . . . . . . . . . . . . . . . . . . . . . . . . 12
Pump Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
246419 Riser Tube Kit . . . . . . . . . . . . . . . . . . . . 15
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 16
Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . 16
Feed Pump Kits
2
Complete
Package
(fluid and air)
Pump Kit
(1 pump and
riser tube)
Pump Model
Maximum Air Input
Pressure
Maximum Fluid Working
Pressure
246369
246375
246376
246655
246081
247955
246366
246367
246368
246654
246898
247956
Husky™ 515
Husky™ 716
Husky™ 1050
Triton™ 308
T2 2:1 Ratio
T1 2:1 Ratio
100 psi (0.7 MPa, 7 bar)
100 psi (0.7 MPa, 7 bar)
125 psi (0.86 MPa, 8.6 bar)
115 psi (0.8 MPa, 8 bar)
180 psi (1.2 MPa, 12.5 bar)
180 psi (1.2 MPa, 12.5 bar)
100 psi (0.7 MPa, 7 bar)
100 psi (0.7 MPa, 7 bar)
125 psi (0.86 MPa, 8.6 bar)
115 psi (0.8 MPa, 8 bar)
405 psi (2.8 MPa, 28 bar)
360 psi (2.5 MPa, 25 bar)
309815R
Related Manuals
Related Manuals
Manual Conventions
The following manuals are shipped with feed pump kits.
Refer to these manuals for detailed equipment information.
Warning
WARNING
Feed Pumps
Part No.
Description
308981
308981
312877
313435
309303
311882
312766
Husky 515 Pump
Husky 716 Pump
Husky 1050 Pump Operation
Husky 1050 Pump Repair-Parts
Triton 308 Pump
T2 2:1 Ratio Pump
T1 2:1 Ratio Pump
The following manuals are shipped with Reactor™.
Refer to these manuals for detailed equipment information.
Reactor Electric Proportioner
Part No.
312065
312066
312062
312063
A warning alerts you to possible serious injury or
death if you do not follow instructions.
Symbols, such as fire, explosion, and electric shock
(shown), alert you to a specific hazard and direct you
to read the indicated hazard warnings on pages 4-4.
Caution
CAUTION
A caution alerts you to possible equipment damage or
destruction if you do not follow instructions.
Note
Description
Reactor Electric Proportioner,
Operation Manual (English)
Reactor Electric Proportioner,
Repair-Parts Manual (English)
Reactor Hydraulic Proportioner,
Operation Manual (English)
Reactor Hydraulic Proportioner,
Repair-Parts Manual (English)
A note indicates additional helpful information.
The following manual is shipped with Fusion™ spray
gun. Refer to this manual for detailed equipment information.
Fusion Spray Gun
Part No.
Description
309550
Instruction Manual (English)
309815R
3
Warning
WARNING
FIRE, EXPLOSION, AND ELECTRIC SHOCK HAZARD
Solvent and fumes in work area can ignite or explode. To help prevent fire and explosion:
• Use equipment only in well ventilated area.
• Eliminate all ignition sources, such as pilot lights, cigarettes and plastic drop cloths (potential static
arc).
• Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.
• Keep the work area free of debris, including solvent, rags, and gasoline.
• Ground equipment and conductive objects. See Ground system, page 7.
• Hold gun firmly to side of grounded pail when triggering into pail.
• Use only grounded hoses.
• If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment
until you identify and correct the problem.
• To avoid chemical reaction and explosion, do not use 1,1,1-trichloroethane, methylene chloride,
other halogenated hydrocarbon solvents or fluids containing such solvents in pressurized aluminum
equipment.
EQUIPMENT MISUSE HAZARD
Misuse can cause serious injury or death.
• For professional use only.
• Use equipment only for its intended purpose. Call your Graco distributor for information.
• Read manuals, warnings, tags, and labels before operating equipment. Follow instructions.
• Check equipment daily. Repair or replace worn or damaged parts immediately.
• Do not alter or modify equipment. Use only Graco parts and accessories.
• Do not exceed the maximum working pressure or temperature rating of the lowest rated system
component. See Technical Data in all equipment manuals.
• Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all
equipment manuals. Read fluid and solvent manufacturer’s warnings.
• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
• Do not use hoses to pull equipment.
• Comply with all applicable safety regulations.
BURN HAZARD
This equipment is used with heated fluid, which can cause equipment surfaces to become very hot. To
avoid severe burns:
• Do not touch hot fluid or equipment.
• Allow equipment to cool completely before touching it.
• Wear gloves if fluid temperature exceeds 110°F (43°C).
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or
swallowed.
• Read Material Safety Data Sheet (MSDS) to know the specific hazards of the fluids you are using.
• Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
PERSONAL PROTECTIVE EQUIPMENT
You must wear proper protective equipment when operating, servicing, or when in the operating area of
the equipment to help protect you from serious injury, including eye injury; inhalation of toxic fumes; and
hearing loss. This equipment includes but is not limited to:
• Protective eyewear.
• Gloves, clothing, and respirator as recommended by the fluid and solvent manufacturer.
• Hearing protection.
4
309815R
Installation
Installation
For Husky 1050 Wall Mount Kit 246368, see page
8.
a.
Inspect bung o-ring (309) and gasket
(303) in place. If either is worn or damaged, or if ISO shows signs of crystallization, replace. See page 15.
For Standard 2:1 Kit 246081, see page 8.
1. Flush pumps before
using
b.
plied with desiccant dryer (6). Screw
dryer 3/4 npt fitting into vent of A component (ISO) drum.
Feed pumps are tested with oil. Flush out oil with
a compatible solvent before spraying. See Flushing in Reactor operation manual.
WARNING
Read warnings, page 4. Flush equipment only in a
well-ventilated area. Do not spray flammable fluids.
Do not turn on heaters while flushing with flammable
solvents.
Remove elbow and 2 in. bushing sup-
CAUTION
Lubricate bung o-ring (309) with 217374 ISO Pump
Oil each time you change drums. This keeps air and
moisture from reacting with isocyanate and allows
bung adapter to rotate freely.
c.
Open drum bung hole.
2. Keep A and B components separate
CAUTION
To prevent cross-contamination of fluid, mark A component (ISO) pumps, hoses, and connections with red
tape. Mark B component (RES) pumps, hoses, and
connections with blue tape. Do not interchange or
cross-connect A component and B component parts.
CAUTION
Tighten pump clamps and external fasteners before
first use. See pump manual.
d.
Place riser tube into drum. Tighten bung
adapter (304) securely.
3. Position drums
Place component A (ISO) and component B
(RES) drums as desired. Air hose (C) connecting feed pumps is 15 ft (4.57 m) long. See FIG.
1.
4. Install pump kit (101)
309815R
5
Installation
246655 Package shown installed in Reactor proportioning system.
Includes * parts only.
103*
NOTE: System shown
includes 246978 Circulation
Kit, available separately,
which includes two 247616
desiccant dryers (6).
101* (ISO)
304*
*101 (RES)
2
C*
*102
*103
2
2
102*
2*
6*
Air Supply Kit. See 309827.
2
*2
*103 (Ref)
103* (Ref)
D
2
2*
TI7690A
FIG. 1. Installation
6
309815R
Installation
5. Connect fluid supply kit
a.
Install swivel union (102) in pump fluid
outlet. Triton 308 only: Install 90° elbow
(104) in pump outlet, then install swivel
union (102) in elbow.
3
WARNING
Read warnings, page 4.
a.
Used on Triton 308 packages only.
102
7. Ground system
104
Feed pump: follow instructions in separate feed pump manual, supplied.
3
b.
Reactor: see Reactor operation manual.
c.
Spray gun: see gun manual.
d.
Fluid supply containers: follow your
local code.
TI3513a
b.
Connect hose (103) between swivel
e.
Object being sprayed: follow your local
code.
union (102) and Reactor swivel inlet (D).
See FIG. 1.
f.
6. Install air supply kit (2).
a.
Solvent pails used when flushing: follow
your local code. Use only metal pails,
which are conductive, placed on a
grounded surface. Do not place pail on
a nonconductive surface, such as paper
or cardboard, which interrupts grounding continuity.
Supply clean, dry, filtered air to feed
pumps.
b.
See manual 309827 to install air supply
kit.
309815R
g.
To maintain grounding continuity when
flushing or relieving pressure, hold a
metal part of spray gun firmly to the side
of a grounded metal pail, then trigger
gun.
7
Installation
Husky 1050 Wall Mount
Standard 2:1 Kit
1. Be sure wall can support weight of pump, hoses,
and accessories, and can withstand stress during
operation.
1. Follow steps 1-3, page 5.
2. Position wall bracket (204) no more than 5 ft (1.52
m) above floor. Check that bracket is level. Attach to
wall, using screws long enough to keep bracket
from vibrating. See FIG. 2.
3. Connect swivel union (205) to pump inlet.
4. Install bushing (3) in pump air inlet.
5. Install pump (201) on bracket (204) securely, using
provided dampeners, washers, and lock nuts.
2. Open drum bung hole. Screw bung adapter with
gasket into bung hole. See pump manual 311882.
3. Install swivel fitting (1c) in pump fluid outlet. See
FIG. 3.
4. Connect hose (1b) between swivel fitting (1c) and
Reactor swivel inlet (D, see FIG. 1).
5. Remove elbow and 2 in. bushing supplied with desiccant dryer (6, see FIG. 1). Screw dryer 3/4 npt fitting into vent of A component (ISO) drum.
6. Follow steps 6-7, page 7, to finish installation.
6. Connect elbow (206) to top of riser tube kit (202).
7. Connect suction hose (203) to elbow (206) and inlet
swivel (205).
8. Follow steps 1-7, pages 5-7, to finish installation.
1a
3
203
201
205
Bung
adapter
1c
1b
206
202
TI10281a
WLD
FIG. 3. Standard 2:1 Kit
204
FIG. 2. Husky 1050 Wall Mount
8
309815R
Operation
Operation
Startup
Shutdown
1. See Load fluid with feed pumps in Reactor operation manual.
See Shutdown and Pressure Relief Procedure in
Reactor manual. Close feed pump bleed-type master air
valve.
2. Open feed pump air regulator.
3. Open feed pump bleed-type master air valve.
Changing Drums
4. Adjust air to feed pump with needle valve.
Cold, viscous material may be difficult to prime.
Use needle valve to reduce air flow to motor.
Do not plug or shut off pump fluid outlet when
priming. Fluid must be free to flow through pump
to prime.
To increase pump flow rate and reduce icing,
remove pump muffler. This will increase exhaust
noise.
5. Never let pump run when drum is empty. A dry
pump can accelerate and damage itself. If pump is
running too fast, stop it immediately. Check and refill
fluid supply, or flush with compatible solvent.
Always prime entire system to remove any air. Do
not let material harden in pump.
CAUTION
To prevent cross-contamination of fluid when changing drums, complete changing one component before
changing second component.
1. See Shutdown above.
2. Remove riser tube from drum. Install in new drum,
page 5.
3. Lubricate bung o-ring (309), page 5.
4. See Load fluid with feed pumps in Reactor operation manual.
Maintenance
See supplied pump manual for maintenance,
repair, and parts information.
Lubricate bung o-ring (309) with 217374 ISO Pump Oil
each time you change drums. This keeps air and moisture from reacting with ISO.
Whenever pump is removed from drum, inspect bung
o-ring (309) and gasket (303) in place. If either is worn
or damaged, or if ISO shows signs of crystallization,
replace. See page 15.
Tighten pump clamps and external fasteners periodically. See pump manual.
309815R
9
Parts
Parts
Complete Feed Pump Packages
Part No. 246369, Husky 515 Package
Part No. 246375, Husky 716 Package
Part No. 246376, Husky 1050 Package
Part No. 246655, Triton 308 Package
(shown)
Ref.
No. Part No.
1
246481
246482
246676
246677
2
246483
3
100206
6
7
246655 Package shown installed
in Reactor proportioning system.
Includes * parts only.
2
NOTE: System shown
includes 246978 Circulation
Kit, available separately,
which includes two 247616
desiccant dryers (6).
Description
Qty
FLUID SUPPLY KIT, Husky 515
1
FLUID SUPPLY KIT, Husky 716
1
FLUID SUPPLY KIT, Husky 1050
1
FLUID SUPPLY KIT, Triton 308
1
AIR SUPPLY KIT; see 309827
1
BUSHING, air inlet; 1/2 npt(m) x 1/4
2
npt(f); 246376 only; see page 14 for
location
247616 KIT, desiccant dryer; for ISO side
1
104969 BUSHING, reducer; 1/2npt(m) x 3/4
1
npt(f); use on 1/2 in. ISO inlet hose
(not shown)
1* (ISO)
1
6* (ISO)
1 1* (RES)
2*
1* (Ref)
2*
2
1* (Ref)
2*
2
1
Fluid Supply Kit. See page 12.
2
Air Supply Kit. See 309827.
TI7690A
10
309815R
Parts
Part No. 246081, T2 2:1 Package
Ref.
No.
1
1a
1b
Part No.
246898
295616
217382
1c
157785
1d
113344
2
246483
6
247616
Description
Qty
KIT, fluid supply
1
PUMP, 2:1; see 311882
2
HOSE, fluid; 3/4 npt (mbe); 3/4 in.
2
(19 mm) ID; 10 ft (3.05 m); nylon
FITTING, swivel; 3/4 npt(m) x 3/4
2
nps(f)
FITTING, swivel; 1/2 npt(m) x 3/4
1
nps(f); (not shown) (use as
necessary to adapt 1/2 npt ISO
inlet)
AIR SUPPLY KIT; see page 10 and
1
309827
KIT, desiccant dryer; for ISO side;
1
see page 10
1a
1c
1b
Part No. 247955, T1 2:1 Package
Ref.
No.
1
1a
1b
Part No.
247956
256200
217382
1c*
113344
1d
113344
2
246483
6
247616
Description
Qty
KIT, fluid supply
1
PUMP, 2:1; see 312766
2
HOSE, fluid; 3/4 npt (mbe); 3/4 in.
2
(19 mm) ID; 10 ft (3.05 m); nylon
FITTING, swivel; 1/2 npt(m) x 3/4
3
nps(f)
FITTING, swivel; 1/2 npt(m) x 3/4
1
nps(f); (not shown) (use as
necessary to adapt 1/2 npt ISO
inlet)
AIR SUPPLY KIT; see page 10 and
1
309827
KIT, desiccant dryer; for ISO side;
1
see page 10
T2 shown
TI10282a
*Use additional 1/2 NPT x 3/4 NPSF fitting to adapt to
1/2 NPT inlet if necessary.
309815R
11
Parts
Fluid Supply Kits
Part No. 246481, Husky 515 Kit
104
102
Part No. 246482, Husky 716 Kit
1
103
101
Part No. 246676, Husky 1050 Kit
Part No. 246677, Triton 308 Kit (shown)
Ref.
No.
101
102
Part No.
246366
246367
246368
246654
157785
202965
113344
103
217382
104
217430
105
104969
12
Description
Qty
PUMP KIT, Husky 515; 246481
2
PUMP KIT, Husky 716; 246482
2
PUMP KIT, Husky 1050; 246676
2
PUMP KIT, Triton 308; 246677
2
UNION, swivel; 3/4 npt(m) x 3/4
2
npsm(f); 246481 and 246482
UNION, swivel; 1 in. npt(m) x 3/4
2
npsm(f); 246676
UNION, swivel; 1/2 npt(m) x 3/4
2
npsm(f); 246677
HOSE, fluid; 3/4 npt (mbe); 3/4 in.
2
(19 mm) ID; 10 ft (3.05 m); nylon
ELBOW, swivel; 90°; 3/8 npt(m) x
2
1/2 npsm(f); 246677 only
BUSHING, reducer, 1/2 npt(m) x
1
3/4 npt(f); use on 1/2 npt ISO inlet
hose (not shown)
1
Used on 246677 only.
TI3449a
309815R
Parts
Pump Kits
Part No. 246366, Husky 515 Pump
Ref.
No.
201
202
Part No. Description
246484 PUMP, Husky 515; see 308981
and read CAUTION below
246419 RISER TUBE KIT; see page 15
Part No. 246367, Husky 716 Pump
Qty
1
CAUTION
246484 Husky 515 Pump is built specifically for use
with isocyanates and is tested with oil. To order
replacement parts and repair kits, refer to the Husky
515 parts list in manual 308981.
1
Ref.
No.
201
202
203
Part No. Description
246485 PUMP, Husky 716; see 308981
and read CAUTION below
246419 RISER TUBE KIT; see page 15
158555 NIPPLE, reducing; 1 in. npt x 3/4
npt
Qty
1
1
1
CAUTION
246485 Husky 716 Pump is built specifically for use
with isocyanates and is tested with oil. To order
replacement parts and repair kits, refer to the Husky
716 parts list in manual 308981.
201
201
202
203
202
TI3450a
309815R
13
Parts
Part No. 246368, Husky 1050 Pump
Part No. 246654, Triton 308 Pump
Ref.
No.
201
Ref.
No.
201
202
203
202
203
204
205
206
Part No. Description
Qty
647673 PUMP, Husky 1050; see 312877
1
and 313435, and read CAUTION
below
246419 RISER TUBE KIT; see page 15
1
214961 HOSE, suction; 3/4 npt (mbe);
1
3/4 in. (19 mm) ID; 6 ft (1.8 m);
neoprene
24C637 KIT, bracket, wall (includes mount1
ing hardware)
202965 UNION, swivel, pump inlet;
1
1 in. npt(m) x 3/4 npsm(f)
107409 ELBOW, swivel, riser tube; 90°;
1
1 in. npt(m) x 3/4 npsm(f)
CAUTION
647673 Husky 1050 Pump is built specifically for use
with isocyanates and is tested with oil. To order
replacement parts and repair kits, refer to the Husky
1050 parts list in manual 313435.
1
203
Part No.
233500
246419
158555
Description
PUMP, Triton 308; see 309303
RISER TUBE KIT; see page 15
NIPPLE, reducing; 1 in. npt x 3/4
npt
Qty
1
1
1
201
203
202
3
201
205
TI3447a
206
202
204
WLD
1
14
See page 10 for description.
309815R
Technical Data
246419 Riser Tube Kit
Ref.
No.
301
302
303
304
305
306
307
308
309
Part No.
159101
156592
106537
15B728
15B727
15B921
100279
159100
110831
Description
HOUSING, valve, intake
TUBE, riser
GASKET, bung
ADAPTER, bung
FITTING; 1 in. npt
SPACER
BALL
RETAINER, ball
O-RING
305
Qty
1
1
1
1
1
1
1
1
1
304
309
1
303
302
1
307
308
301
306
Lubricate with 217374 ISO Pump Oil
each time you change drums.
TI3445a
Technical Data
Category
Maximum air input pressure
Maximum fluid working pressure
Wetted parts
309815R
Data
Husky 515: 100 psi (0.7 MPa, 7 bar)
Husky 716: 100 psi (0.7 MPa, 7 bar)
Husky 1050: 125 psi (0.86 MPa, 8.6 bar)
Triton 308: 115 psi (0.8 MPa, 8 bar)
T2 2:1 Ratio: 180 psi (1.2 MPa, 12.5 bar)
T1 2:1 Ratio: 180 psi (1.2 MPa, 12.5 bar)
Husky 515: 100 psi (0.7 MPa, 7 bar)
Husky 716: 100 psi (0.7 MPa, 7 bar)
Husky 1050: 125 psi (0.86 MPa, 8.6 bar)
Triton 308: 115 psi (0.8 MPa, 8 bar)
T2 2:1 Ratio: 405 psi (2.8 MPa, 28 bar)
T1 2:1 Ratio: 360 psi (2.5 MPa, 25 bar)
Pump: see supplied pump manual
Riser tube: carbon steel
Fluid hoses: nylon
Suction hose (Husky 1050 only): neoprene
Fittings: carbon steel
15
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs
will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite
de ou en rapport, directement ou indirectement, avec les procédures concernées.
Graco Information
For the latest information about Graco products, visit www.graco.com.
For patent information, see www.graco.com/patents.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
2ULJLQDOLQVWUXFWLRQV This manual contains English. MM 309815
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
Copyright 2003, Graco Inc. is registered to ISO 9001
www.graco.com
Revision R, April 2016