installation, instruction and service manual

Add to my manuals
6 Pages

advertisement

installation, instruction and service manual | Manualzz

PLATINUM SMART-HEAT™

ELECTRIC HEATER SERIES II

BY BROMIC

INSTALLATION, INSTRUCTION AND

SERVICE MANUAL

AVAILABLE IN 2300W VERSION

Original Instructions

Version 2.0 EU

!

IMPORTANT

READ THIS MANUAL CAREFULLY.

SEE INSIDE COVER FOR IMPORTANT INFORMATION ABOUT

THIS MANUAL. KEEP INSTRUCTION WITH APPLIANCE FOR

FUTURE REFERENCE.

!

IMPORTANT

This manual contains important information about the installation, operation, and maintenance of Platinum

Smart-Heat™ Electric Heaters. Please pay close attention to the important safety information shown throughout this instruction manual. Any safety information will be accompanied by the following safety alert symbols:

• READ THIS MANUAL CAREFULLY before installing or servicing this product.

• Improper installation, operation, or maintenance can result in death, severe injury, or property damage.

• This appliance is intended for fixed installation with 220-240V AC single-phase power supply.

• Installation MUST be carried out by a licensed and authorised technician in accordance with local electrical codes.

• This product is intended for domestic and commercial use.

Correct Disposal of this product

This marking indicates that this product should not be disposed with other household wastes throughout the

EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer from whom the product was purchased so that they may organise environmentally safe recycling.

CONTENTS

IMPORTANT NOTES & WARNINGS

PRODUCT OVERVIEW

PRODUCT DESCRIPTION

SPECIFICATIONS

PRODUCT FEATURES

HEATER INSTALLATION INSTRUCTIONS

CEILING & WALL MOUNTING

CEILING RECESS

TUBE SUSPENSION

ELECTRICAL INSTALLATION

SERVICING

TROUBLESHOOTING

2

Head Office: 10 Phiney Place, Ingleburn, NSW 2565 Australia

Telephone: 1300 276 642 (within Australia) or +61 2 9748 3900 (from overseas) Fax: +61 2 9748 4289

Email: [email protected] Web: www.bromicheating.com

Note: Bromic Pty Ltd reserves the right to make changes to specifications, parts, components and equipment without prior notification.

This installation, operation and service manual may not be reproduced in any form without prior written consent from Bromic Pty Ltd. www.bromicheating.com

www.bromicheating.com

3

11

11

11

9

10

5

6

6

4

5

5

5

IMPORTANT NOTES AND WARNINGS

!

WARNING

• IMPORTANT - Installation MUST be carried out by a licensed and authorised person.

licenced service person only. The heater should be inspected before use and at least annually serviced and inspected by a qualified and licenced service person.

• Improper installation, adjustment, or alteration and failure to follow the warnings and instructions in this manual could result in severe personal injury, death or property damage.

• Do not perform maintenance until heater has been turned off, power disconnected, and heater temperature has cooled to room temperature.

• The manufacturer is not responsible for any damage resulting from improper use. The manufacturer emphasises that this appliance should be used in a responsible manner and that all procedures, warnings, and safety instructions contained in this booklet should be followed strictly.

• Certain materials or items, when stored under or near the appliance, will be subjected to radiant heat and could be seriously damaged. Combustible materials eg. walls, floors, furniture, fixtures and plants must be kept a minimum of 1000mm from the heater.

• Clothing or other flammable materials should not be hung from the heater or placed on or near the heater.

• The installer is to ensure that the requirements of the local authority, local electrical installation code, municipal building codes, and any other relevant statutory regulations are carried out.

• Be sure the heater is not facing the ceiling or flammable or combustible substances/materials.

• Do not place articles on or against this appliance.

• This radiant heater is NOT intended to be installed on recreational vehicles and/or boats.

• Do not use or store flammable materials near this appliance

• Do not attempt to alter the unit in any manner.

• This installation, operation and service manual should not be removed from the site of installation. Installer should leave manual with the customer for future reference.

• Remove transit protection before use.

• A minimum safety distance of 1000mm should always be left in front of the appliance.

• Never operate the heater in an explosive environment such as areas where petrol or other flammable liquids or vapours are stored.

• Do not paint any surface of the heater.

• This unit must be mounted at a minimum of 1800 mm above the floor.

• The appliance must not be located immediately below or in front of an electrical socket outlet. Heat radiated from the appliance may damage the electricity outlet or plug if placed incorrectly.

• Check for damage to the appliance regularly. The heater must not be used if the glass panel or any other part of the heater is damaged. If damage to the appliance is suspected, discontinue use immediately and contact the supplier or qualified person to repair.

• After unpacking, make sure the appliance shows no signs of visible damage or tampering. If the appliance appears damaged, contact the place of purchase for assistance.

• Any guard or other protective device removed for servicing

(conducted by an authorised person) must be replaced before operating the heater.

• This appliance must only be used on a 220-240V AC single-phase power supply.

• This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.

• Do not touch the heating surface at any time, even when the heater is turned off and has cooled down.

• Do not touch the heater with wet hands at any time.

• Heaters are not intended to be installed in wardrobes.

• If the appliance has not been used, or will not be used, for a long period of time, disconnect power supply

• Children shall not play with the appliance.

• Cleaning and user maintenance shall not be made by children without supervision.

• Children of less than 3 years should be kept away unless continuously supervised.

• Some parts of this product can become very hot and cause burns.

Particular attention has to be given where children and vulnerable people are present.

• At the end of this product’s useful life, it must not be disposed of as domestic waste, but must be taken to a collection centre for waste electrical and electronic equipment. It is the user’s responsibility to dispose of this appliance through the appropriate channels at the end of its useful life. Failure to do so may incur the penalties established by laws governing waste disposal. Proper differential collection, and the subsequent recycling, processing and environmentally compatible disposal of waste equipment avoids unnecessary damage to the environment and possible related health risks, and also promotes recycling of the materials used in the appliance. For further information on waste collection and disposal; contact your local waste disposal service or the place of purchase.

• Keep packaging materials out of reach of children

4

• Do not spray aerosols or flammable materials in the vincinty of this appliance while it is in operation

• Installation and repair must be carried out by a qualified and

• In case of direct connection to a supply line, a bipolar circuit breaker with contact opening distance of at least 3mm must be fitted upstream from the supply line. Contact an authorised service technician if you are unsure if you have a circuit breaker installed on the premises.

www.bromicheating.com

IMPORTANT NOTES AND WARNINGS

CONTINUED

...

• Do not install the heater directly near a bathtub, shower or swimming pool. Any switches or controls must not be within reach of a person in the bathtub, shower or swimming pool.

• To maintain Ingress Protection Rating (IPX5), only IP55 rated conduit fittings should be used for electrical installation.

Keep the cable away from sharp edges during handling and installation.

Do not pull on the cable or subject it to traction force.

Avoid physical shock & impact to the heater when handling.

• This product does not have a switch for electrical disconnection. A means for disconnection of the heater must be incorporated in the fixed wiring according to the local electrical codes.

• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

• This heater is not equipped with a device to control the room temperature. Do not use this heater in small rooms when they are occupied by persons not capable of leaving the room on their own, unless constant supervision is provided.

• Do not bend the electrical connection to the power supply.

• Do not apply any pressure on the glass surface.

• Keep the electrical connection area to the power supply clean.

• Do not install or use the heater in any way other that indicated in the instruction leaflet.

• If any part of the instruction manual is missing or damaged, contact

Bromic for a complete version.

Ensure that the heating unit is not directly exposed to rain or water contact.

If you are unsure of any aspect of the installation, contact Bromic for advice.

PRODUCT OVERVIEW

The Platinum Smart-Heat™ Electric is designed to provide efficient spot heating for commercial and residential applications.

The heaters are built with corrosion resistant materials, have electrical approval in Australia and are rated to IPX5 water Ingress

Protection. Making the Platinum Smart-Heat™ Electric the perfect solution for a variety of indoor and outdoor heating applications.

SPECIFICATIONS

Model

Part no.

Heat Output (Watts)

Power connection required (Volts/Amps)

Dimensions (WxHxDmm)

Weight (kg)

Finish

Approval

2300W

BH0320004

2300W

220-240V - A.C. - 50/60Hz

838 x 177 x 54 mm

7.5kg

Brushed Stainless Steel 304

PRODUCT FEATURES

Ultra-thin and stylish design

▪ Efficient directional spot heating

Heat Zones — one or more heaters can be switched on and off simultaneously from a single remote-located switch

▪ Platinum Smart-Heat™ Electric Heaters can also be integrated into smart control systems

▪ Wind resistant & IPX5 water protection rating

Suitable for outdoor and indoor heating applications such as restaurants, cafes, bars and clubs, factories, office spaces, designated smoking areas, public areas, hotels and more

▪ Standard Mounting - included with heater

Optional Mounting - purchased separately from heater:

Ceiling Recess

▪ Tube Suspension www.bromicheating.com

5

HEATING INSTALLATION INSTRUCTIONS

CEILING & WALL MOUNTING

• Heaters must be installed according to the minimum installation clearances shown in these diagrams

• Minimum distance between heaters measured from edge of heater must be at least 500mm.

• Minimum distance from edge of heaters to any adjacent walls must be at least 250mm. Heaters must be away from the fourth wall.

WALL MOUNTING

CEILING

CEILING MOUNTING

CEILING

250

FLOOR FLOOR

6

!

WARNING

!

WARNING - Outdoor Installation

This heater MUST be permanently installed by an authorised/licenced person. Do not perform maintenance, or carry out installation or assembly procedure while electrical power is switched on. Wait 2 hours after switching off the heater before handling.

Ensure that the heating unit is not directly exposed to rain or water contact. For longest product life and to maintain product appearance, mount heater under cover and protect from rain and weather.

www.bromicheating.com

HEATING INSTALLATION INSTRUCTIONS

CONTINUED...

OPTION 1

To exit the cable through the side of the wall mounting bracket, start from step 1.

b

1. Unscrew and remove plug-in wall bracket (a).

2. Attach extra supplied cable gland into the same hole from the outside of the bracket. Fasten in place with the metal cable gland nut from inside the bracket

(b).

NOTE: Continue to step 3 below

Optional: Cable exit through wall bracket

OPTION 2

To exit the cable through the wall bracket directly into your ceiling or wall cavity, start from step 3.

3. Attach mounting bracket to ceiling or wall using fasteners appropriate for the surface (c). Ensure the bracket is firmly secured with fasteners in all 4 holes before proceeding. For wall mounting , ensure the silver plug or cable gland (a) is facing upwards.

!

WARNING: The bracket mounting surface MUST be protected from rain. This is necessary to stop water entering the bracket & maintain IPX5 rating.

4. Ensure M6x14mm screws are inserted into both sides of heater bracket with 6mm of the threaded shaft exposed under the screw head (d).

5. For cable exit through the side of the wall bracket: feed heater power cable through cable gland in wall bracket (e).

NOTE: This is easier when the top of the cable gland is completely removed when feeding the cable through the bracket. The cap can then be inserted onto the cable for fastening.

6. For cable exit into the ceiling or wall cavity: make a small hole in the black foam on the bracket mounting surface to pass the cable through. Make electrical connection now or feed cable into wall or ceiling for subsequent connection (f).

This is described under ‘Electrical Installation’ on page 11.

7. Insert heater bracket into mounting bracket by hooking M6 screws into place in mounting slots (g).

a

110

Wall mount

80 c d

Ceiling mount

g f e

Cable exit into wall cavity

www.bromicheating.com

7

8

8. To fix heater at desired angle, fully insert M4x10mm positioning screws on both sides of mounting bracket whilst holding heater in the desired position

(h). The heater can positioned straight, or be angled 30deg either way.

9. Fit the smaller cover over the heater bracket so that the slots pass over the

HEATING INSTALLATION INSTRUCTIONS

CONTINUED...

10. Tighten mounting screws firmly, ensuring covers fit snugly against the bracket on all sides (k).

10. Tighten mounting M6 screws firmly, ensuring covers fit snugly against the bracket on all sides (k).

j k

Angle bracket option h i j h i

Straight bracket option

www.bromicheating.com

k

230

/ 9.1 "

870

/ 34.2"

9.1”

HEATING INSTALLATION INSTRUCTIONS

CONTINUED...

CEILING RECESS (SOLD SEPARATELY)

!

WARNING

Instructions below are suitable for ceiling surfaces 10-30mm thick. For ceiling surfaces thicker than 30mm, contact Bromic for alternative installation options.

!

WARNING

Minimum vertical ceiling space clearance between the heater frame and ceiling surface must be 250mm.

Minimum horizontal ceiling space clearance measured from each edge of ceiling cut out must be 500mm.

Minimum distance between heaters measured from edge of ceiling cut out must be 500mm.

!

WARNING

The heater shall, under no circumstance, be covered with insulating material or similar material.

1. Prepare ceiling cut-out with dimensions 870mm x 230mm to fit ceiling recess frame (a) . Heater must be installed with heater surface at least

2400mm above the floor level, with 500mm clearance to the nearest wall on all sides of the heater.

2. From below, bring ceiling frame up and into ceiling cutout. Fasten ceiling frame into cut-out at both ends and centre using appropriate screws (b) . Which locator hole to use is dictated by the thickness of the ceiling surface. The fastening screws must be inserted into a strong material that can easily support the weight of the heater. Your installation may require re-enforcing before the frame can be safely installed.

3. Unscrew and remove plug-in wall bracket. Attach extra supplied cable gland into the same hole from the outside of the bracket. Fasten in place with metal cable gland nut from inside the bracket (c) .

4. Feed heater power cable through cable gland from inside of wall bracket (d) .

5. Ensure M6x14mm screws are inserted into either side of heater bracket with 6mm of the threaded shaft exposed under the screw head. (e).

6. Insert heater bracket into mounting bracket by hooking M6 screws into place in mounting slots (f) .

7. Fix heater to bracket in straight position using M4x10mm positioning screws on either side of mounting bracket (g) . Ensure M6 screws are sitting fully in the mounting slots (as if the heater were hanging from the wall bracket).

8. Fit the smaller, straight cover over the heater bracket so that the slots pass over the shafts of the M6x14mm mounting screws (h). Fit the larger cover over the smaller cover in the same way from the opposite side of the bracket (i) .

9. Tighten mounting screws firmly, ensuring covers fit snugly against the bracket on all sides (j) .

10. Firmly tighten cable gland in wall bracket so that cable does not move when pulled.

!

WARNING

Joists, beams and rafters shall not be cut or notched to install the heater.

230

/ 9.1 "

870 c e c d e f b a d g g h h i www.bromicheating.com

i

9 i b a

9.1” f c e d g h

35.2” f b a i e c d g h

35.2” f b a

11. Attach the bracket end-cap to the wall bracket using the 4 M5 screws and nuts provided (k).

HEATING INSTALLATION INSTRUCTIONS

screws with both halves of the ceiling support bracket in place and tighten firmly. (l)

CONTINUED...

11. Attach the bracket end-cap to the wall bracket using the 4 M5 screws and nuts provided (k).

12. Carefully remove the 4 M5 screws fastening the heater mounting bracket to the back of the heater. Be careful not to move or put any force on the bracket. Place the 2 halves of the ceilling recess mounting plate over the screwholes. Re-insert the screws & tighten firmly. (l)

13. Make electrical connection from heater to power supply. This is described under ‘Electrical Installation’ ceiling frame . Ensure the heater brackets are hooked over the ceiling frame and sitting in the slots on both sides. (o)

14. Raise one long side of heater up into ceiling frame cavity & then raise whole heater into cavity. (m)

15. Rotate the heater into level position in the ceiling cavity (n) and then lower down onto the ceiling frame . Ensure the heater brackets are hooked over the ceiling frame and sitting in the slots on both sides. (o) o m k j l n

TUBE SUSPENSION

• Heater must be installed with heater surface at least

2400mm above the floor level.

• Installation is identical to ‘Ceiling & Wall Mounting’ above.

• Use ceiling bracket (sold separately) instead of mounting bracket supplied with heater.

• Ceiling pole only suitable for ceiling mounting. Do not wall mount.

10 www.bromicheating.com

ELECTRICAL INSTALLATION

!

WARNING

This heater MUST be permanently installed by an authorised/ licenced person. Do not perform maintenance, or carry out installation or assembly procedure while electrical power is switched on.

!

WARNING

ELECTRICAL SHOCK HAZARD! Serious injury or death may occur.

Disconnect from electrical supply before installing or servicing this heater. Read and follow installation clearance requirements outlined in this manual. The appliance MUST be connected to a properly grounded electrical source.

ELECTRICAL INSTALLATION

1. Check product label for correct voltage and wattage to ensure sure power source conforms to the heaters requirements.

2. Use appropriate power supply cables for the heaters’ voltage and wattage. The fixed wiring must be positioned away from

& protected from the enclosure of the heater.

3. Make all connections in accordance with local electrical code regulations. For outdoor installation, all connections must be made in accordance with local electrical code regulations for outdoor wiring. Only use wiring components approved for outdoor use with minimum IPX5 rating.

SERVICING

!

WARNING

ELECTRICAL SHOCK HAZARD!

Serious injury or death may occur. Disconnect from electrical supply before servicing this heater.

MAINTENANCE

For longest product life, and to maintain product appearance, mount heater under cover and protect from rain and weather whenever possible.

!

WARNING

Servicing and maitenance MUST be carried out by an authorised and licenced service person only.

!

WARNING

If the supply cord is damaged, it must be replaced by Bromic, a service agent of Bromic or similarly qualified persons in order to avoid a hazard. Contact Bromic for further information on replacement of the supply cord.

The exterior housing of the heater should be cleaned regularly.

To clean the appliance; ensure heater is off, and has been off for at least 2 hours after operation, before wiping off any dirt/dust with a soft damp cloth.

Salt in the air can cause rusting of metal, especially at locations near the coast. Additional cleaning of the heater with a soft damp cloth fortnightly will aid in maintaining the product’s appearance.

TROUBLESHOOTING

SYMPTOM

No heat

Not enough heat

Too much heat

POSSIBLE CAUSE (S)

1. Improper connection

1. Heater too small for application

2. Heater mounted too high or too far

1. Heater too large for application

2. Heater mount too low or too close

CORRECTIVE ACTION

1. Check connection to power supply

1. Add additional heater(s)

2. Decrease mounting height or distance

1. Replace with smaller heater

2. Increase mounting height or distance www.bromicheating.com

11

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement