Operating instructions
Operating instructions
Daikin Control unit RoCon BF, EHS157034, EHS157068
Operating instructions
Daikin Control unit RoCon BF, EHS157034, EHS157068
Daikin 
RoCon BF
EHS157034
EHS157068
English
Table of contents
1
General safety precautions. . . . . . . . . . . . . . 4
1.1
Particular safety instructions . . . . . . . . . . . . . . . . 4
1.1.1
1.1.2
1.2
Observing the instructions. . . . . . . . . . . . . . . . . . . . 5
Meaning of warnings and symbols . . . . . . . . . . . . . 5
Safety instructions for installation and operation . 6
1.2.1
1.2.2
Product description. . . . . . . . . . . . . . . . . . . . 7
3
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.3
3.4
Operating concept . . . . . . . . . . . . . . . . . . . . . . . 10
Basic functions and operating modes . . . . . . . . 10
3.4.1
3.4.2
3.4.3
3.4.4
3.4.5
3.4.6
3.4.7
3.4.8
3.4.9
3.5
Emission measurement. . . . . . . . . . . . . . . . . . . . .
Manual operation . . . . . . . . . . . . . . . . . . . . . . . . .
STL Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-way switching valves reference travel. . . . . . . .
4.2
4.3
Access rights (technician code) . . . . . . . . . . . . . .
Heat slope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Weather-dependent T-HS control . . . . . . . . . . . . .
Air Purge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Anti-legionella system . . . . . . . . . . . . . . . . . . . . . .
Resetting to factory setting . . . . . . . . . . . . . . . . . .
Screed program . . . . . . . . . . . . . . . . . . . . . . . . . .
Relay test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Settings for optional circulation pump . . . . . . . . . .
Remote control via Internet . . . . . . . . . . . . . . . . . .
Frost protection function . . . . . . . . . . . . . . . . . . . .
Heating support . . . . . . . . . . . . . . . . . . . . . . . . . .
Special function: Switching contacts . . . . . . . . . . .
SmartStart function . . . . . . . . . . . . . . . . . . . . . . .
21
22
23
23
24
24
25
27
27
27
27
27
28
28
Fundamental aspects of the IDs and 
authorisations in the RoCon system . . . . . . . . . 29
Operating support during initial commissioning 
and during system extensions . . . . . . . . . . . . . . 30
Putting the Daikin heat generator into 
operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
4.3.1
4.4
Assigning the terminal ID on the RoCon B1 control
unit to the Daikin heat generator . . . . . . . . . . . . . . 31
Putting optional RoCon system components into
operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
4.4.1
4.4.2
4.4.3
4.4.4
4.4.5
Mixer module EHS157068 . . . . . . . . . . . . . . . . . .
EHS157034 room station . . . . . . . . . . . . . . . . . . .
Allocating the EHS157068 mixing module to a 
heat generator. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Master RoCon function . . . . . . . . . . . . . . . . . . . . .
Caretaker function. . . . . . . . . . . . . . . . . . . . . . . . .
Operating instructions
2
19
20
20
21
5.3.1
5.3.2
5.3.3
5.3.4
5.3.5
5.3.6
5.3.7
5.3.8
5.3.9
6
35
36
36
36
36
36
36
36
36
36
Rotary switch setting: Info . . . . . . . . . . . . . . . . . .
Rotary switch setting: Operating Mode . . . . . . . .
Rotary switch setting: Set Temp Day . . . . . . . . . .
Rotary switch setting: Set Temp Night . . . . . . . . .
Rotary switch setting: DHW Set Temp . . . . . . . . .
Rotary switch setting: DHW Reheating . . . . . . . .
Rotary switch setting: Time Program . . . . . . . . . .
Rotary switch setting: Remote Param . . . . . . . . .
Rotary switch setting: Configuration . . . . . . . . . . .
37
37
37
37
37
37
37
37
37
Parameter settings . . . . . . . . . . . . . . . . . . . 38
6.1
6.2
Explanation of the parameter tables . . . . . . . . . 38
Rotary switch setting: Configuration . . . . . . . . . 38
6.2.1
6.2.2
6.2.3
6.2.4
6.2.5
6.2.6
6.3
6.4
6.5
6.6
6.7
6.8
6.9
6.10
6.11
6.12
6.13
"Setup" level . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
"System Configuration" level . . . . . . . . . . . . . . . . .
"HC Configuration" level . . . . . . . . . . . . . . . . . . . .
"DHW Configuration" level . . . . . . . . . . . . . . . . . .
"Expert Config" level (only heat generator A1) . . .
"Lambda-Gx" level (only for the heat generator
GCU compact). . . . . . . . . . . . . . . . . . . . . . . . . . . .
38
40
41
42
43
Rotary switch setting: DHW Reheating . . . . . .
Rotary switch setting: Operating Mode . . . . . .
Rotary switch setting: Set Temp Day . . . . . . . .
Rotary switch setting: Set Temp Night . . . . . . .
Rotary switch setting: DHW Set Temp . . . . . . .
Rotary switch setting: Time Program . . . . . . . .
Rotary switch setting: Remote Param . . . . . . .
Rotary switch setting: Info . . . . . . . . . . . . . . . .
Exit key: Special Level . . . . . . . . . . . . . . . . . . .
"Basic Configuration" parameter level. . . . . . . .
Parameter levels of the EHS157068 mixer 
module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
44
45
45
45
45
46
46
47
48
48
44
49
6.13.1 Rotary switch setting: Configuration , 
"Setup" level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
6.13.2 Rotary switch setting: Configuration , 
"Mixer Config" level . . . . . . . . . . . . . . . . . . . . . . . . 50
7
Errors and faults . . . . . . . . . . . . . . . . . . . . . 52
7.1
Detecting errors and rectifying faults. . . . . . . . . 52
7.1.1
7.1.2
7.1.3
7.1.4
31
32
33
33
33
Rotary switch setting: Configuration . . . . . . . . . . .
Rotary switch setting: DHW Reheating . . . . . . . .
Rotary switch setting: Operating Mode . . . . . . . .
Rotary switch setting: Set Temp Day . . . . . . . . . .
Rotary switch setting: Set Temp Night . . . . . . . . .
Rotary switch setting: DHW Set Temp . . . . . . . . .
Rotary switch setting: Time Program . . . . . . . . . .
Rotary switch setting: Remote Param . . . . . . . . .
Rotary switch setting: Info . . . . . . . . . . . . . . . . . .
Exit key: Special function . . . . . . . . . . . . . . . . . . .
Parameter levels for the EHS157068 mixer 
module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
5.3
10
12
14
14
14
14
14
17
17
Initial commissioning . . . . . . . . . . . . . . . . . 29
4.1
5.2.1
5.2.2
5.2.3
5.2.4
5.2.5
5.2.6
5.2.7
5.2.8
5.2.9
5.2.10
Special system settings . . . . . . . . . . . . . . . . . . . 21
3.6.1
3.6.2
3.6.3
3.6.4
3.6.5
3.6.6
3.6.7
3.6.8
3.6.9
3.6.10
3.6.11
3.6.12
3.6.13
3.6.14
4
System information (Info) . . . . . . . . . . . . . . . . . . .
Setting the operating mode . . . . . . . . . . . . . . . . . .
Temperature setting of daytime room temperature
Temperature setting of setback mode. . . . . . . . . .
Temperature setting of hot water generation . . . .
Unscheduled hot water generation . . . . . . . . . . . .
Switching time program. . . . . . . . . . . . . . . . . . . . .
System settings. . . . . . . . . . . . . . . . . . . . . . . . . . .
Terminal function. . . . . . . . . . . . . . . . . . . . . . . . . .
Special functions . . . . . . . . . . . . . . . . . . . . . . . . 19
3.5.1
3.5.2
3.5.3
3.5.4
3.6
Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Operating elements. . . . . . . . . . . . . . . . . . . . . . . . . 9
For first commissioning or resetting to factory
settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
After first commissioning/After successful basic
configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
5.2
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Display and operating elements. . . . . . . . . . . . . . 8
3.2.1
3.2.2
Parameter overview. . . . . . . . . . . . . . . . . . . 34
5.1
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Use as intended . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2
3.1
3.2
5
7.2
7.3
8
Current error display . . . . . . . . . . . . . . . . . . . . . . .
Reading the error protocol. . . . . . . . . . . . . . . . . . .
Deleting errors, unlocking the firing unit . . . . . . . .
Rectifying faults . . . . . . . . . . . . . . . . . . . . . . . . . . .
52
52
53
53
Emergency operation . . . . . . . . . . . . . . . . . . . . 54
Error codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Table of contents
9
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
9.1
User-specific settings . . . . . . . . . . . . . . . . . . . . 59
9.1.1
9.1.2
9.1.3
9.2
Switching time program . . . . . . . . . . . . . . . . . . . . . 59
Parameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Data bus addresses . . . . . . . . . . . . . . . . . . . . . . . 60
Notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
10 List of keywords . . . . . . . . . . . . . . . . . . . . . 63
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
3
1 x General safety precautions
1
General safety precautions
1.1 Particular safety instructions
WARNING!
Heating devices that have not been set up and installed correctly can impair the function of the
heating device and/or cause serious or fatal injuries to the user.
● Work on the Daikin heat generator (such as set-up, servicing, connection and initial start-up) must
only be carried out by persons who are authorised and who have successfully completed qualifying technical or vocational training and who have taken part in advanced training sessions
recognised by the relevant responsible authorities for the specific activity. These include, in
particular, certified heating engineers, qualified electricians and HVAC specialists who,
because of their professional training and their expert knowledge, have experience in the
professional installation and maintenance of heating systems, oil and gas installations and hot
water storage systems.
● Only operate the Daikin heat generator in perfect condition with the protective hood closed.
WARNING!
Disregarding the following safety instructions may result in serious physical injury or death.
● This equipment must only be used by children aged 8 and above and by persons with restricted
physical, sensory or mental capabilities or with a lack of experience and knowledge, if they are
under supervision or if they have been instructed in the safe use of the equipment and understand the dangers arising therefrom. Children must not play with the equipment. Cleaning and
user maintenance must not be carried out by children without supervision.
● Make up the power supply in accordance with IEC 60335-1, via a separator device which exhibits
contact separation in all poles with a contact opening distance that provide full disconnection in
accordance with overvoltage category III.
● All the electrical work must only be carried out by electrically qualified experts and with consideration of the local and national regulations, and the instructions in this manual.
Check that a suitable electrical circuit is being used.
Inadequate capacity of the power circuit or improperly executed connections can cause electrocution or fire.
Operating instructions
4
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
1 x General safety precautions
1.1.1 Observing the instructions
1.1.2 Meaning of warnings and symbols
● The original documentation is written in
German. All other languages are translations.
● Please read this manual and applicable
documents carefully and thoroughly before
proceeding with the installation or modification of the heating system.
● The precautionary measures described in this
document cover very important topics. Follow
them meticulously.
Warnings in this manual are classified according
into their severity and probability of occurrence.
DANGER!
Draws attention to imminent danger.
Disregarding this warning can lead to serious
injury or death.
All the activities required for operation and adjustment are described in this manual. All
heating parameter needed for smooth operation
are already factory-set.
Indicates a potentially dangerous situation.
● Make a note of the preset values before you
make any changes to the unit configuration.
Disregarding this warning may result in serious
physical injury or death.
Relevant documents
– Daikin heat generator:
– the associated installation and maintenance instructions for the specialised company
– the operating instructions for the operator
and
– the operating manual for the operator.
– For connecting to a Daikin solar system:
the associated installation and operating
instructions.
– For connecting to another Daikin heat generator or optional accessories:
the associated installation and operating
instructions.
The guides are included in the scope of supply
for the individual units.
WARNING!
CAUTION!
Indicates a situation which may cause possible
damage.
Disregarding this warning can cause damage to
property and the environment, and result in
minor injuries.
This symbol identifies user tips and particularly useful information, but not warnings or hazards.
Special warning signs
Some types of danger are represented by
special symbols:
Electric current
Risk of burns
Validity
Some information in this manual has limited validity. The validity is highlighted by a symbol.
Only valid for oil fired heating unit A1
Only valid for GCU compact
Only valid/available for connected control
Only valid/available for connected mixer
module
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
5
1 x General safety precautions
Handling instructions
● Handling instructions are shown as a list.
Actions for which the sequential order must be
maintained are numbered.

Results of actions are identified with an
arrow.
Entry into a setting procedure
Exit from a setting procedure
1.2 Safety instructions for installation and
operation
1.2.1 General
● For any work on the equipment, which
extends above and beyond the operation of
the regulating system, you must observe the
details provided in the supplementary
documents, particularly with regard to safety
instructions.
Avoiding danger
Alls Daikin heat generators conform to the stateof-the-art and meets all recognised technical
requirements. However, improper use may result
in serious physical injuries or death, as well as
property damage.
To avoid danger, only operate the Daikin heat
generator:
– as stipulated and in perfect condition,
– with an awareness of safety and the hazards
involved.
This assumes knowledge and use of the contents of this manual, of all applicable documents,
of the relevant accident prevention regulations
as well as the recognised safety-related and occupational health rules.
1.2.2 Use as intended
The RoCon BF control unit must only be used in
Daikin oil and gas fired heating units that are released for the Daikin RoCon control system. The
Daikin RoCon BF control unit must only be operated in accordance with the specifications of
this manual.
Any other use outside the intended use is considered as improper. The operator alone shall
bear responsibility for any resulting damage.
Operating instructions
6
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
2 x Product description
2
Product description
The RoCon BF control unit is part of the boiler control
panel in Daikin heat generators.
It consists of the switching panel PCB to which the actuators and sensors, as well as other components in the Daikin
RoCon regulating system, are connected, and the
RoCon B1 operating unit.
In this instruction manual we explain just the functions and
setting possibilities of the control unit. More information on the
boiler control panel and other equipment components can be
found in the supplementary documents.
The electronic, digital control unit is able to automatically control
all heating and hot water functions for a direct heating circuit, a
storage loading circuit and also further heating circuits via optionally connectible mixer modules, depending on the heating
device.
Certain menu items of the RoCon BF control unit are only accessible for the heating expert. This security measure ensures that
no undesirable malfunctions arise during operation of the system
through incorrect settings.
The EHS157034 room controller has the same operating surface
as the heat generator in which the RoCon B1 control unit is integrated.
All settings for the allocated heating circuit can be carried out in
the same way as the operating unit. With activated terminal
function, all operating possibilities that are available on the integrated operating unit are available, with the exception of certain
special functions (e.g. Emission Measurement).
A connected EHS157068 mixer module is also operated according to the respective allocation via the RoCon B1 control unit
and/or the control unit EHS157034 controller.
In combination with the firing unit it takes over the overall safety
management of the Daikin heat generator. This executes a safety
switch-off in the event of a water shortage or undefined operating
states. A corresponding error message shows the operator all the
information on the fault cause.
The setting positions of the 3-way switching valves with the
GCU compact are continuously adapted to the operating situation of the heating system.
Advantages:
– Lower number of burner starts and higher degree of efficiency
due to SmartStart function
– optimised solar heating support
All function settings for the Daikin heat generator and the optional
RoCon devices connected via the data bus are carried out with
the operating elements of the integrated RoCon B1 control panel
and displayed in clear text display on a coloured backlit display.
The regulation data bus can be used to connect the following
additional, optional devices to the Daikin heat generator:
– EHS157034.
– EHS157068.
With connected RoCon OT1, the T-HS can be controlled depending on the weather with frost protection functions. For all
Daikin heat generators with the RoCon BF control unit, this
outside temperature sensor is included in the scope of delivery.
If the optional EHS157056 is installed and connected with the Internet, the Daikin heat generator can be conveniently monitored
and operated by remote control using a mobile phone (App).
The RoCon BF control unit contains a timer which can be used to
set:
– 2 individually adjustable switching time programs the room
heating (direct heating circuit),
– 2 individually-adjustable timer programs for hot water generation,
– 1 individually-adjustable timer program for an optional circulation pump.
Furthermore, the RoCon BF control unit has a frost protection
function for the direct heating circuit and the storage loading
circuit, as well as the possibility of integrating an additional heat
source (wood boiler, solar system) via a potential-free burner
blocking contact.
Initial commissioning of the heating system is described in the installation manual of the Daikin heat generator.
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
7
3 x Operation
3
Operation
3.1 General
The colour of the backlighting indicates the operational status
and the operating mode:
DANGER!
White:
Standard lighting, normal operating display.
If electrical components come into contact with
water, this can cause an electric shock as well
as cause potentially fatal burns or injuries.
Red:
Error status; depending on the type of error, the
Daikin heat generator continues to operate with
restrictions.
Green:
Operating mode with operator authorisation.
● The displays and the keys of the control unit
must be protected against the effects of
moisture.
● To clean the control unit, use a dry cotton
cloth. Using aggressive cleaning agents
and other liquids can cause damage to
equipment or lead to an electric shock.
Blue:
Operating mode with expert authorisation.
3.2 Display and operating elements
1
2
3
4
5
6
Display date
Burner activity status
Expert login display
Time display
Current T-HS
Heating circuit status
Fig. 3-2
Item
fig. 3-2
1
2
3
4
5
6
Clear text display
Setting: Configuration
Setting: Remote Param
Rotary switch
Setting: Info
Setting: Operating Mode
Fig. 3-1
7
8
9
10
11
12
13
Setting: Set Temp Day
Setting: Set Temp Night
Setting: DHW Set Temp
Rotary button
Setting: DHW Reheating
Setting: Time Program
Exit key
All operating steps are supported by corresponding displays on a
coloured backlit plain text display.
For troubleshooting instructions, see chap. 7.
Operating instructions
8
Display of the control unit - standard display
Icon
Explanation
Heat requirement active
3
Expert access rights active (see
chap. 3.6.1)
2/3
Air purge active (see chap. 3.6.4)
2/3
Terminal function active (see chap. 3.4.9)
2/3
Frost protection function active (see
chap. 3.6.11)
2/3
Temporary time program "Party" active (see
chap. 3.4.7)
2/3
Temporary time program "Away" active
(see chap. 3.4.7)
2/3
Temporary time program "Holiday" active
(see chap. 3.4.7)
2/3
Temporary time program "Vacation" active
(see chap. 3.4.7)
2/3
Screed program active (see chap. 3.6.7)
5
The menu guidance can be displayed 7 languages (see
chap. 3.4.8).
Faults are generally indicated by an error code and a
clear text error message on the display.
Current outside temperature
Active operating mode
Hot water generation status
Current storage temperature
2
Arrangement of display and operating elements
3.2.1 Display
7
8
9
10
Direct heating circuit
–
5
During normal operation, the current THS tV1 is displayed underneath.
Mixer circuit
The current T-HS of the assigned heating
circuit is displayed underneath.
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
3 x Operation
Item
fig. 3-2
Icon
Explanation
Action
Result
Turning
5
Room temperature sensor
Direct selection of the main function level
assigned to this switch position.
The current room temperature is displayed
underneath.
6
Heating circuit status
–
–
7
Heating circuit active (room heating
function)
Heating circuit not active (currently no
thermal transport in the heating circuit)
External temperature sensor
The current outside temperature is displayed underneath.
8
Current operating mode (see chap. 3.4.2)
Tab. 3-2 Function of the rotary switch
Rotary button
The rotary button can be used to navigate in the respective level,
to select or change the setting value and to accept this change
with a short key press.
Action
Turning
Standby active
To the right (+): increasing adjustment
Reducing active
To the left (–): decreasing adjustment
Heating active
Summer active
Automatic 1 active
Touching
Confirm selection, accept setting, execute
function.
Automatic 2 active
9
Result
Hot water generation active
Hot water generation not active
10
Hot water heating circuit status
The current storage temperature tDHW1 is
displayed underneath.
Tab. 3-3 Functions of the rotary button
Exit key
Tab. 3-1 Explanation of display symbols
This key can be used to jump back to the previous display within
a menu item or to cancel a function/input.
When the screed function is activated (see chap. 3.6.7), the
symbol is displayed in the upper display line.
The special level can also be called up using this key (see
chap. 3.5).
3.2.2 Operating elements
CAUTION!
Never operate the operating elements of the
control unit with a hard, pointed object. This can
cause damage and can cause the control to
malfunction.
If special key combinations or long key presses are required for
certain functions, these are referred to separately in the respective section of this manual.
Action
Touch briefly.
Result
–
–
Press for longer –
than 5 seconds.
Return to the previous display or the previous level or
cancel a special function or a one-time
active time program
A special level is called up.
Tab. 3-4 Functions of the Exit key
Rotary switch
Frequently required functions and setting options can be quickly
and directly selected using the rotary switch (main function level).
Regardless of the rotary switch position, the Daikin heat
generator operates according to the operating mode
which was set in the "Operating Mode"
switch
position or which was activated by a special program.
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
9
3 x Operation
3.3 Operating concept
–
The operating concept of the RoCon BF control unit is designed
so that frequently required setting options can be accessed
quickly and directly at the main function level (selection by
means of rotary switch) and less frequently required setting options are arranged on a lower lying parameter level.
–
–
–
–
–
9
Keylock
8
1
7
2
6
3
5
4
1
2
3
4
5
6
7
8
9
Switch status on the EBA input (external requirement
request)
SmartStart function
Frost protection function
Screed program
Air Purge
Manual operation
The control panel of the RoCon BF can be locked against inadvertent operation (see fig. 3-4).
It is unlocked in the same way.
Precondition for this function is that the [Keylock Function] parameter at the "Setup" level is set to "On" (see chap. 6.2.1,
tab. 6-1).
Operating Mode (chap. 3.4.2)
Set Temp Day (chap. 3.4.3)
Set Temp Night (chap. 3.4.4)
DHW Set Temp (chap. 3.4.5)
DHW Reheating (chap. 3.4.6)
Time Program (chap. 3.4.7)
Configuration (chap. 3.4.2)
Remote Param (chap. 3.4.9)
Info (chap. 3.4.1)
Fig. 3-3
Keylock Function
On
Illustration of the main function level (rotary switch position)
Keylock Function
Certain functions and parameters are restricted by access rights
and can only be configured by a heating expert (see chap. 3.6.1).
In normal operation, the rotary switch should be in the
sition.
po-
After switching on and successful initialisation, the standard
display automatically shows the display for the rotary switch
.
setting
Keylock Function
Off
During initial start-up, the setting for the language selection is first
displayed.
● Select the language with the rotary button.
● Confirm the selection with a brief push of the rotary button.
Adaptations to the special system configuration are
rotary switch setting
made in the "Configuration"
(see chap. 3.4.8).
If the system is switched on, the defaults set in the RoCon BF
control unit fully automatically control the operation of the
– room heating and the
– hot water generation plumbing.
Regardless of the rotary switch position, the Daikin heat
generator operates according to the operating mode
which was set in the "Operating Mode"
switch
position or which was activated by a special program.
If the user sets a value manually, this setting remains active until
the user changes it or until the timer program forces a different
mode of operation.
The operating modes can be affected by additional functions
such as:
– Weather-dependent T-HS control
– Switching time program
– Setting the temperature target value
– Setting on the room station
– Setting on the room thermostat
– Switch status on the EXT input (external operating mode
changeover)
Operating instructions
10
Fig. 3-4
Activating and deactivating the keylock
3.4 Basic functions and operating modes
3.4.1 System information (Info)
In this rotary switch setting, all system temperatures, the heat
generator type, various software information and the operating
states of all system components can be successively queried by
means of rotary button. The number of displayed parameters depends on which components are connected.
No adjustments can be made to these values.
● Set the rotary switch to the "Info"
position.
 Standard display is shown (see fig. 3-2).
● Press the rotary button briefly.
 Parameter overview is displayed.
● Use the rotary button to select the desired information level.
● Confirm the selection with a brief push of the rotary button.
 An overview is displayed (example, see fig. 3-6).
● Use the rotary button to select the individual information.
Detailed explanations and possible display values for this rotary switch setting can
be found in chap. 6.10.
Display operating data
On the "Overview" information level on the display of the
RoCon BF control unit, the current operating data of the Daikin
heat generator is displayed.
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
3 x Operation
The display of the operating data is split over several screen
pages. Adjust the rotary button to navigate between the screen
pages.
Short designation
Mode
Explanation of the display value
Info
Current mode of the heat generator:
- - -: No heat requirement
SST: SmartStart function active
Overview
Water Pressure
Page 1
: Heating
: Hot water generation
Stat
Burner status
–
: Burner on
–
: Burner off
RT
[Room thermostat] parameter = Off: - - [Room thermostat] parameter = On:
–
: Heat requirement
–
: No heat requirement
Pump Current capacity of the internal heating circulation
pump in %
Mix1
Current position of the distributor valve
–
3UV1: CH / DHW
–
3UV DHW: 0 % (CH) - 100 % (DHW)
Mix2
Current position of the mixer valve
–
n.a.
–
3UVB1: 0 % (B) - 100 % (A: Bypass)
TV
Page 2
TVBH
TR
Tdhw
TA
V
Current T-HS on the boiler output (tV1)
Current temperature of heating flow (after
heating support heat exchanger if necessary) (tV2)
Fig. 3-5
Current temperature of heating return (tR1)
Displaying the water pressure
Current temperature in the hot water storage tank
(tDHW1)
On the RoCon BF control unit, the system pressure (water
pressure) of the internal circuit (direct heating circuit) can be displayed when it is switched on. The water pressure is the first
available Info parameter (see fig. 3-6).
Current outside temperature (measured by
RoCon OT1 temperature sensor)
Actual flow rate in the heating system
Tab. 3-5 Explanation of the operating data displayed as an overview
Display of operating data
The permissible range of the water pressure during heating is dependent on the heat generator and the heating system. The
target values and thresholds may only be set by the heating
expert. If the water pressure drops below the minimum value (set
parameter value), it must be increased by topping up the system
(see installation manual for the heat generator).
The pressure limits for the safety shut-down and the
target pressure can be set in the parameter settings at
the "System Configuration" level.
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
11
3 x Operation
● Set the rotary switch to the "Operating Mode"
position.
 An overview is displayed.
● Use the rotary button to select the required operating mode.
● Confirm the selection with a brief push of the rotary button.
 The Daikin heat generator works according to the set
operating mode.
 The current operating mode is indicated by an appropriate
symbol on the standard display.
Standby operating mode
Info
Overview
CAUTION!
Water Pressure
T-HS
Water Pressure
A heating system that is not protected against
frost can freeze in the event of frost and thus be
damaged.
● Drain the heating system on the water side if
there is a danger of frost.
● If there is a danger of frost and the heating
system is not drained, the current and fuel
supplies must be secured and the mains
switch must remain switched on.
3.4.2 Setting the operating mode
In this operating mode, the Daikin heat generator is switched to
standby operation. The frost protection function remains unchanged. In order to maintain this function, the system may not
be disconnected from the mains.
The selection of the operating mode in which the Daikin heat generator is to work is made on the rotary switch in the "Operating
Mode"
position.
For an outside temperature below the [T-Frost Protect] parameter value, the integrated heating circulation pump is switched on
to prevent the heating system freezing.
The selected operating mode is activated by briefly pressing the
rotary button.
All controllers integrated in the RoCon system via the CAN bus
are primarily also switched to the "Standby" operating mode.
Fig. 3-6
Displaying Info values (e.g. system pressure)
Operating Mode
Heating
Summer
Automatic 1
Operating Mode
Operating Mode
Automatic 1
Standby
Automatic 2
Fig. 3-8
Reducing
Standard display in the [Standby] operating mode 
(above the frost limit temperature)
Operating Mode
Automatic 1
Automatic 2
Fig. 3-7
Changing the operating mode 
(e.g. from "Standby" to "Automatic 2")
Operating instructions
12
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
3 x Operation
In the [Standby] operating mode, the burner is disconnected from the power supply (energy efficiency) if the
following conditions are fulfilled:
–
–
–
–
–
–
The burner has been off for at least 5 min
The outdoor temperature sensor (RoCon OT1) is connected and correctly parametrised in the system configuration
The outside temperature is more than 3 °C
The frost protection function is not active in any connected
heating circuit
No communication error to the firing unit is pending and
the Daikin heat generator has been switched on for at least
10 min.
Operating mode Reducing
Reduced heating (lower target room temperature) according to
the setback temperature set in the [T-Reduced] parameter (see
chap. 3.4.4).
Hot water generation according to the set target temperatures
and switching cycles in the [DHW Program 1] hot water time
program (see chap. 3.4.5).
Operating mode Heating
Heating according to the target room temperature set in the [TRoom 1 Setpoint] parameter (see chap. 3.4.3). A connected
outside temperature sensor (weather-dependent T-HS control
unit) or a connected room control unit also influence the target THS.
Hot water generation according to the set target temperatures
and switching cycles in the [DHW Program 1] hot water time
program (see chap. 3.4.5).
Operating mode
Resistance
Standby
< 680 Ω
Heating
1200 Ω
Reducing
1800 Ω
Summer
2700 Ω
Automatic 1
4700 Ω
Automatic 2
8200 Ω
The resistances specified in tab. 3-6 function in a tolerance field of 5%. Resistances outside this tolerance
field are interpreted as an open input. The heat generator switches back to the previously active operating
mode.
The input is not considered for resistance values greater than
the value for "Automatic 2".
Besides these operating modes, different temporary heating programs (see tab. 3-7) are available that are carried out with priority
after activation.
Temporary
heating
program
Setting/Activation in the level
Rotary
switch
setting
Information
Emission Measurement
Special Level
Any
Chap. 3.5.1
DHW Reheating
DHW Reheating
Chap. 3.4.6
Party
Time Program
Chap. 3.4.7
Chap. 3.6.7
Away
Holiday
Only hot water generation is carried out according to the set
target temperatures and switching cycles in the [DHW Program
1] hot water time program (see chap. 3.4.5).
Vacation
Screed*
Configuration > HC
Configuration
All controllers integrated in the RoCon system via the CAN bus
are primarily also switched to the "Summer" operating mode.
STL Test*
Special Level
Automatic heating and setback mode according to the permanent
time programs (see chap. 3.4.7):
– [HC Program 1]
– [DHW Program 1]
Automatic 2 operating mode (time program)
Automatic heating and setback mode according to the permanent
time programs (see chap. 3.4.7):
– [HC Program 2]
– [DHW Program 2]
±5%
Tab. 3-6 Operating mode changeover via EXT input
Operating mode Summer
Automatic 1 operating mode (time program)
Tolerance
Any
Chap. 3.5.3
* only with technician code.
Tab. 3-7 Overview of temporary heating program
If a temporary heating program (Emission Measurement, DHW Reheating, Party, Away, Holiday, Vacation, Screed, STL Test) is started during the selected
operating mode, the control is carried out with priority
given to the settings for this heating program.
If the hot water readiness is in setback mode in the
active operating mode,
a temporary "DHW Reheating" can be set with the rotary switch setting
without having to change other standard settings (see
chap. 3.4.6).
EXT input
Connected via the J8 connection of the heat generator
on the "EXT" terminals and potential-free contact wired
with a resistance, the operating mode can also be changed from
an external device (e.g. solar control unit, modem, …) (see
tab. 3-6).
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
13
3 x Operation
3.4.3 Temperature setting of daytime room
temperature
3.4.6 Unscheduled hot water generation
The target room temperatures during the day are determined for
rotary switch setting.
the room heating in the
● Set the rotary switch to the "Set Temp Day"
 An overview is displayed.
position.
The last digits of the parameter designations (1 - 3)
within this rotary switch setting mark the affiliation to the
respective cycle of the time program.
● Select the temperature block to be set with the rotary button.
● Confirm the selection with a brief push of the rotary button.
 Settings are displayed.
● Set the temperature.
● Confirm the selection with a brief push of the rotary button.
 The change has been accepted. Jump back to the previous display.
Detailed explanations and possible setting values for this rotary switch setting can
be found in chap. 6.5.
3.4.4 Temperature setting of setback mode
In the
rotary switch setting, the room target temperatures are
determined in the setback mode for the room heating.
● Set the rotary switch to the "Set Temp Night"
position.
 An overview is displayed.
● Select the parameter to be set with the rotary button.
● Confirm the selection with a brief push of the rotary button.
– [T-Reduced]: Setting value for [Reducing] operating mode
or setback due to permanent time program.
– [T-Absence]: Setting value for temporary heating programs ("Away" and "Vacation").
 Settings are displayed.
● Set the temperature.
● Confirm the selection with a brief push of the rotary button.
 The change has been accepted. Jump back to the previous display.
Detailed explanations and possible setting values for this rotary switch setting can
be found in chap. 6.6.
3.4.5 Temperature setting of hot water generation
In the
rotary switch setting, the hot water target temperatures
are determined for the hot water generation of the respective time
programs.
● Set the rotary switch to the "DHW Set Temp"
position.
The last digits of the parameter designations (1 - 3)
within this rotary switch setting mark the affiliation to the
respective cycle of the time program.
● Select the temperature block to be set with the rotary button.
● Confirm the selection with a brief push of the rotary button.
 Settings are displayed.
● Set the temperature.
● Confirm the selection with a brief push of the rotary button.
 The change has been accepted. Jump back to the previous display.
Detailed explanations and possible setting values for this rotary switch setting can
be found in chap. 6.7.
Operating instructions
14
In the
rotary switch setting, the hot water can be manually
reheated to the preset target temperature in the [T-DHW Setpoint
1] parameter outside of a hot water time program. The heating up
is carried out with priority and independent of other heating programs.
● Set the rotary switch to the "DHW Reheating"
position.
 An overview is displayed.
● Select the parameter to be set with the rotary button.
– [1x Hot Water]: Activation of one-time hot water generation.
– [DHW Reloadtime]: Activation of time-limited hot water
generation.
● Confirm the selection with a brief push of the rotary button.
● Set the parameter.
● Confirm the selection with a brief push of the rotary button.
 The unscheduled hot water generation starts.
The two functions cannot be combined with each other.
After this temporary function has elapsed, the control
unit automatically jumps back to the previously active
operating mode. The rotary switch should therefore be brought
position after the function has been acback into the "Info"
tivated.
Possible setting values of this rotary switch setting can be found in chap. 6.3.
3.4.7 Switching time program
For comfortable and individual room and hot water temperature
control, different (but freely adjustable) time programs preset at
the factory can be selected.
The switching time programs control the assigned heating circuit,
the storage charging circuit as well as an optionally connected
circulation pump according to the specified switching times.
Setting
In the
rotary switch setting, the time intervals for the
heating circuit, integrated hot water generation and the optional
circulation pump are set.
● Set the rotary switch to the "Time Program"
position.
 An overview is displayed.
● Use the rotary button to select the time program to be set.
● Confirm the selection with a brief push of the rotary button.
 Settings are displayed.
● Use the rotary button to select and change the value to be
adjusted.
● Confirm the selection with a brief push of the rotary button.
Detailed explanations and possible setting values of this rotary switch setting can be
found in the chapter 6 "Parameter settings".
Permanent time programs
Time programs control the heating circuit temperatures or the operating times of the circulation pump according to the specified
switching cycles for the connected heating circuits and the
storage charging circuit. The switching cycles are saved in time
blocks for which different target temperatures can be set.
In the switching cycles, the heating system is controlled differently according to day and setback mode.
The temperature settings for these time programs are carried out
via the target value settings "Set Temp Day"
, "Set Temp
Night"
and "DHW Set Temp"
.
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
3 x Operation
The following switching time programs are available:
– 2 time programs for the heating circuit, each with 3 possible
switching cycles
– [HC Program 1]
– [HC Program 2]
The times can be entered separately for each individual
weekday or in blocks of "Monday to Friday", "Saturday
to Sunday" and "Monday to Sunday".
Program
Time period
HC Program 1
Individual weekday
(Monday, Tuesday …)
1.
2.
3.
06:00 -> 22:00
--:-- -> --:---:-- -> --:--
Working week
(Monday to Friday)
1.
2.
3.
06:00 -> 22:00
--:-- -> --:---:-- -> --:--
Weekend
(Saturday to Sunday)
1.
2.
3.
07:00 -> 23:00
--:-- -> --:---:-- -> --:--
Whole week
(Monday to Sunday)
1.
2.
3.
06:00 -> 22:00
--:-- -> --:---:-- -> --:--
See
HC Program 1
1.
2.
3.
See
HC Program 1
HC Program 2
Switching cycle
[Circulation Time]
The setting and the entry structure of the time program
are identical with those for the heating circuit time
program (see also tab. 3-8).
For further information on settings for an optional circulation
pump, see chap. 3.6.9.
Saved switching time programs can be changed at any time. For
a better overview, it is recommended to write down and safely
store the programmed switching cycles (see chap. 9.1.1).
The permanent time programs are preset according to tab. 3-9.
Tab. 3-8 Menu structure of heating circuit/time program
Time settings for a switching cycle in a weekday or
block program will also be accepted for other time periods as long as they are for the same weekdays. Examples referring to tab. 3-8:
a) The starting time in the 1st switching cycle is changed from
06:00 am to 05:00 am for the individual weekday "Monday".
 The 1st switching cycle is also automatically changed
from 06:00 am to 05:00 am for the "working week" and
"whole week" time periods.
b) The starting time in the 1st switching cycle is changed from
07:00 am to 08:00 am for the "weekend" time period.
 The 1st switching cycle is also automatically changed
from 07:00 am to 08:00 am for the individual weekdays
"Saturday" and "Sunday".
c) The end time in the 1st switching cycle is changed from
10:00 pm to 9:30 pm for the "whole week" time period.
 The 1st switching cycle is also automatically changed
from 10:00 pm to 9:30 pm in all weekday or block programs.
–
2 time programs for the hot water circuit, each with 3 possible
switching cycles
– [DHW Program 1]
– [DHW Program 2]
The setting and the entry structure of the time programs
are identical with those for the heating circuit time
program (see also tab. 3-8).
–
1 time program for an optionally connected circulation
pump with 3 possible switching cycles
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
15
3 x Operation
Switching cycle 1
Time period
On
Off
Switching cycle 2
Switching cycle 3
On
On
Off
Off
Room heating
Temperature setting
[T-Room 1 Setpoint]: 20 °C
[T-Room 2 Setpoint]: 20 °C
[T-Room 3 Setpoint]: 20 °C
[T-Reduced]: 10 °C
"HC Program 1"
Monday - Friday
06:00
22:00
--:--
--:--
--:--
--:--
Saturday, Sunday
07:00
23:00
--:--
--:--
--:--
--:--
"HC Program 2"
Monday - Friday
06:00
08:00
16:00
22:00
--:--
--:--
Saturday, Sunday
07:00
23:00
--:--
--:--
--:--
--:--
Domestic hot water generation
Temperature setting
[T-DHW Setpoint 1]: 60 °C
[T-DHW Setpoint 2]: 60 °C
[T-DHW Setpoint 3]: 60 °C
"DHW Program 1"
Monday - Sunday
05:00
21:00
--:--
--:--
--:--
--:--
"DHW Program 2"
Monday - Friday
05:00
21:00
--:--
--:--
--:--
--:--
Saturday, Sunday
06:00
22:00
--:--
--:--
--:--
--:--
Monday - Friday
05:00
21:00
--:--
--:--
--:--
--:--
Saturday, Sunday
06:00
22:00
--:--
--:--
--:--
--:--
"Circulation Time"
Tab. 3-9 Factory setting of the permanent switching time programs
Temporary time programs
3.
4 temporary time programs are available for special situations,
which make the permanent time programs or the currently set
operating mode ineffective for the duration of their validity.
The symbol of the temporary time program is displayed in the
header of the standard display for as long as the time program is
active.
The following temporary time programs can be cancelled at any time due to the manual changing of the
operating mode.
1.
[Party]: Immediate one-time extension of the room
heating
a) If an automatic program is activated, the last valid
switching cycle is always extended. In the time prior to
switching cycle 1, the control is carried out according to
the target value in the [T-Room 1 Setpoint] parameter.
b) In all other operating modes, work is carried out according
to the set room target temperature of the first switching
cycle.
– The hot water generation is not affected.
– The time program runs for the set time period from activation.
2.
[Away]: Immediate one-time setback up to 6 hours.
In setback mode, work is carried out according to the
room target temperature set in the [T-Absence] parameter
rotary switch setting.
in the "Set Temp Night"
The hot water generation is not affected.
The time program runs for the set time period from activation.
–
–
–
Operating instructions
16
[Holiday]: One-time calendar-controlled presence.
– Control is carried out only according to the settings for
"Sunday" in the [HC Program 1].
– The hot water generation is only controlled according to
the settings for "Sunday" in the [DHW Program 1].
4.
–
–
–
[Vacation]: One-time calendar-controlled setback.
In setback mode, work is carried out only according to the
room target temperature set in the [T-Absence] parameter
rotary switch setting.
in the "Set Temp Night"
Hot water generation according to the set target temperatures and switching cycles in the [DHW Program 1] hot
water time program (see chap. 3.4.5).
The calendar-controlled [Vacation] program is not
started if the [Standby] or [Manual operation] operating
mode is active at the set start date.
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
3 x Operation
3.4.8 System settings
In the "Configuration"
rotary switch setting, the basic settings of the RoCon BF control unit as well as the system configuration for the installation environment of the Daikin heat generator, the direct heating circuit, the hot water generation and any
optionally connected components are carried out.
Depending on the access authorisation (user or expert), different
parameters are available. Several parameters can only be accessed by the heating expert.
Setting the language, date and time
An internally pre-programmed calendar ensures an automatic timeshift for the annually repeating summertime/wintertime changeover dates. If required, the
automatic timeshift can be switched off.
● Set the rotary switch to the "Configuration"
position.
 An overview is displayed.
● Use the rotary button to select the "Setup" level.
 An overview is displayed.
● Use the rotary button to select the [Language], [Date], [Time]
or [Summertime] parameters and confirm.
● Use the rotary button to select and change the value to be
changed within the respective display.
● Confirm the selection with a brief push of the rotary button.
 The change has been accepted. Jump back to the previous display.
Detailed explanations and possible setting values of this rotary switch setting can be
found in chap. 3.6 and in chap. 6.2.
Remote Param
Remote Param
Bus - Scan
Contr BM1/BE1 #1
No selection
Mix Valve #0
Remote Param
Remote Param
Contr BM1/BE1 #1
3.4.9 Terminal function
In the "Remote Param"
rotary switch setting, other devices
(mixer module control unit or heat generator control components)
integrated in the RoCon system via the CAN bus can also be operated and parametrised as long as the respective control unit
has the required authorisation (see also chap. 4.3).
Bus - Scan
Mix Valve #0
No selection
A list of the recognised devices
is displayed for selection on the
display after activation of the
"Bus - Scan" (external devices
and local device).
After selection and confirmation of an external device,
the terminal function for this
device is activated and the associated standard display for
this device is shown on the
display.
The operating component is
then in terminal operation.
Remote Param
No selection
Contr BM1/BE1 #1
Remote Param
Mix Valve #0
Bus - Scan
No selection
Fig. 3-9
Display of the "Remote
Param" level during
commissioning or after
interim disconnection
from the mains
The local control unit functions as a remote control for the external device. In this case, all the control functions are performed
and saved 1:1 as on the external device.
B1
Bus
H1
H2
M1
U1
WE1
RoCon B1 control unit of the heat generator
CAN bus (connection line between RoCon devices
and control units)
Direct heating circuit (e.g. radiators)
Mixed heating circuit (e.g. floor heating)
EHS157068 mixer module
EHS157034 room station
Heat generator
Fig. 3-10 Example of "Bus - Scan" on a heating system with 1 heat generator, 1 mix valve, 1 room station and activation of the terminal function for remote control of the mixer module
The different application and parametrisation options for the use
of the devices and control units in the RoCon system connected
via the CAN bus are described in chap. 4.3.
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
17
3 x Operation
If the terminal function is activated, the
#X symbol is displayed in the header of the display as additional information on
the remote-controlled device, where "X" is the set device identification of the remote-controlled device.
The displayed values and symbols are always accepted by the
selected device (e.g. mixer circuit T-HS of the EHS157068 mix
valve module with device identification 1).
Fig. 3-11 Example of the display for the remote-controlled mixer module
In order to operate the local device, it must be activated again in
the selection list ([No selection] parameter).
If the "n.a." message is displayed in the rotary switch
setting
, no valid terminal ID has been assigned to
the control unit until now.
If the "n.a." message is still displayed, it may be necessary to
update the device software in order to use the terminal function.
Contact the Daikin Service Team for this.
Activating/deactivating terminal operation
Prerequisite: A valid terminal ID has been assigned to the
RoCon B1 control unit of the Daikin heat generator or to the
EHS157034 room station .
For setting the terminal ID of optionally connected devices, see chap. 4.4 or the respective operating instructions that are supplied.
● Set the rotary switch to the "Remote Param"
position.
 The "Remote Param" level is displayed.
● Use the rotary button to select the [Bus - Scan] parameter.
● Confirm the selection with a brief push of the rotary button.
 The context menu is displayed.
● Use the rotary button to select the [Bus - Scan] parameter
and confirm with "Yes".
 Bus - Scan is carried out.
 An overview of all the devices found is displayed (for an
example, see fig. 3-10).
● Use the rotary button to select the device for which the
terminal function should be carried out.
● Confirm the selection with a brief push of the rotary button.
 The local control unit functions as a remote control for the
external device.
To end terminal operation and to switch back to the control unit
for the operation of the assigned device, the [No selection] parameter must be selected and confirmed at the "Remote
Param" level.
After an interim disconnection from the power supply,
the display always appears at the "Remote Param"
level, as shown in fig. 3-9.
To use the terminal function for connected devices, a repeat Bus
- Scan must be carried out.
Communication between the RoCon system components also
continues to function without Bus - Scan and previously made
settings remain active.
The terminal function is activated as shown in fig. 3-10, but after
confirmation of the "Bus - Scan" display, the [New scan?] parameter must be selected with the rotary button and confirmed
with "Yes".
Operating instructions
18
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
3 x Operation
3.5 Special functions
Different functions (mostly useful functions for the heating expert)
can be carried out on the "Special Level".
The following special functions are possible:
– Emission measurement (see chap. 3.5.1)
– Manual operation (see chap. 3.5.2).
– STL test (see chap. 3.5.3)
– 3-way switching valve reference travel
– Error display (see chap. 7)
– Reset to factory settings (see chap. 3.6.6)
Detailed explanations of these functions can be found in chap. 6.11.
The calling-up of the special functions does not depend
on the rotary switch setting.
● Push the Exit button for at least 5 s.
 The "Special Level" menu is displayed.
● Use the rotary button to select the program to be started.
● Confirm the selection with a brief push of the rotary button.
 The selected program starts.
● Cancellation and jump back by:
– pressing the Exit key again or
– touching the rotary button or
– selecting another menu using the rotary switch.
3.5.1 Emission measurement
Caution - Risk of overheating of floor
heating!
In the event of malfunction or during manual
operation, the floor heating, the screed or the
floor structure could be damaged due to overheating.
● Prior to initial commissioning, set the
maximum temperature limit in the RoCon BF
control unit ([Max T-Flow] parameter) to the
maximum permitted system temperature
prior to starting the emission measurement.
During the emission measurement, the T-HS of the heat generator is limited to the value set in the [Max T-HS] parameter. For
additionally connected external heating circuits, the RoCon BF
control unit tries to keep the current T-HS of the heating circuit at
temperatures between 55 °C and 65 °C.
To cool the heat generator during the emission measurement or to bring it up to temperature as quickly as
possible, an acceptance obligation or an acceptance
block can be imposed on the heating circuits by the heat
generator ([Forced Performance] parameter). This parameter
can be used to set whether the heating circuit should react to the
acceptance requirement or not.
● Push the Exit button for at least 5 s.
 The "Special Level" menu is displayed.
● Use the rotary button to select the "Emission Measurement"
program.
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
● Confirm the selection with a brief push of the rotary button.
 The following load types are available for selection:
– Off: The emission measurement is switched off, the heat
generator that may have been switched on by the control
unit continues to run normally.
– Base Load: The heat generator is switched on and operated at the minimum output of the heat generator, irrespective of the set operating mode.
– Full Load: The heat generator is switched on and operated at the maximum output of the heat generator, irrespective of the set operating mode.
● Use the rotary button to select the "Full Load" load type, but
do not confirm it.
 Display: "Full Load"

The burner is switched on for 30 min and controlled to
the specified maximum temperature.

The burner is switched on for 30 min. and is regulated
at maximum load.
●
Use the rotary button to select the "Base Load" load type,
but do not confirm it.
 Display: "Base Load"
 The modulating gas burner runs at minimum output for 30
mins.
● Cancellation and jump back by:
– Again pressing the Exit key or the rotary button
– Use the rotary button to select a different menu and confirm.
Special Level
Emission Measurement
Manual Operation
Emission Measurement
Off
Emission Measurement
Base Load
Emission Measurement
Full Load
Emission Measurement
Full Load
Fig. 3-12 Symbolic brief instructions for emission measurement
Operating instructions
19
3 x Operation
3.5.2 Manual operation
3.5.3 STL Test
Manual operation is used to manually control the heat generator
to a specific T-HS. Manual operation should only be used for diagnostic purposes.
With hydraulically-controlled operation for hot water generation,
it is important to ensure that the T-HS value set in manual operation is sufficient to achieve the saved hot water target temperature ([T-DHW Setpoint 1] parameter).
During active manual operation, the hot water is continuously
controlled to the first target value parameter of the hot water generation ([T-DHW Setpoint 1]).
If manual operation is ended, the RoCon BF control unit automatically switches to "Standby" operating mode.
CAUTION!
Risk of burns from hot surfaces.
● During and after the STL test, only touch the
heat generator and connected hydraulic
components wearing suitable protective
gloves.
● Allow the heat generator to cool down for a
sufficient period of time after the STL test.
CAUTION!
Special Level
Emission Measurement
Manual Operation
Special Level
Emission Measurement
Manual Operation
STL Test
Manual Operation
Set Point
Current Value
Special Level
Risk of overheating during the STL test. The
heat generator and a heating circuit directly
connected to the heat generator could be
damaged during the STL test.
● The STL test must only be carried out by the
heating expert.
● If the direct heating circuit cannot be hydraulically uncoupled before the STL test (e.g.
floor heating), it must be manually lockable
on both sides.
● To prevent damage to the heat generator, a
bypass line must be installed before the STL
test.
● If the heat resistance of the material installed
in the direct heating circuit is less than
105 °C, it must be locked and a bypass line
opened before carrying out the STL test.
Attention!
Actual mode:
Fig. 3-13 Symbolic brief instructions for manual operation
1
2
3
Heat generator
Directly connected heating
circuit
Close shut-off valve (flow)
4
Close shut-off valve (return)
5
Open shut-off valve (bypass)
MAG 
Diaphragm expansion vessel
Fig. 3-14 Hydraulic switch for the STL test during heating circuit installation with heat resistance less than 105 °C
The STL function switches off the burner at an inadmissibly high
boiler temperature and locks it against being switched on again
automatically.
The limit temperatures are permanently defined in the firing unit
of the respective heat generator and cannot be changed.
Operating instructions
20
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
3 x Operation
The STL test can be carried out to check the STL function:
3.6 Special system settings
● Enter the technician code (see chap. 3.6.1).
 After entering, the "Setup" level is displayed.
● Push the Exit button for at least 5 s.
 The "Special Level" menu is displayed.
● Use the rotary button to select the "STL Test" program.
● Carry out the program by continuously pressing on the rotary
button.
 "STL Test" is displayed on the display.
The integrated heat generator maximum temperature limit
is continuously bypassed and the heat generator continues to operate at full load without limitation until the safety
temperature limitation is triggered.
 All externally connected consumers are disconnected
from the heat generator on the water side (available mix
valves are closed). With the exception of the boiler pump,
all heating circuit and storage loading pumps are inactive.
● Release the rotary button.
 The STL test is ended.
● If the STL test (safety shut-down with error code E1) is
successful:
After sufficient cooling down, the safety temperature limiter
(STL) must be manually unlocked to switch back to normal
heating operation. See chap. 7.1.3 and the installation and
operating instructions of the respective heat generator.
The RoCon BF control unit is already basically configured for the
Daikin heat generator. However, it must still be adjusted during
commissioning for optionally connected accessories and the installation environment.
3.5.4
The adjustment is carried out by setting the parameters in the
"Configuration" rotary switch setting
.
The next lowest level can be accessed or the respective parameter directly accessed by navigation with the rotary button.
3.6.1 Access rights (technician code)
Certain settings in the control unit are limited by access rights. To
receive access to these parameters, the technician code must be
entered at the "Setup" level.
Figure 3-15 shows the basic procedure for entering the access
code. The expert company receives the technician code in a separate letter.
3-way switching valves reference travel
The positions of the two 3-way switching valves 3UVB1 and
3UV DHW in the Daikin GCU compact are controlled continuously between their two basic settings for optimised energy utilisation (e.g. heating support function).
Configuration
Access Rights
Setup
System Configuration
To ensure this function, the two 3-way switching valves are
always moved automatically to their home position (bypass - path
AB-A open) on the weekdays "Monday", "Wednesday" and
"Friday" at 11:00 am.
This function can take up to 5 minutes. It is programmed as
standard and cannot be changed.
Setup
Language
Access Rights
User
Date
Setup
Keylock Function
Access Rights
Access Rights
Expert
HZU
Access Rights
Access Rights
Fig. 3-15 Entering the access code
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
21
3 x Operation
3.6.2 Heat slope
Caution – Risk of overheating of
floor heating!
In the event of malfunction or during manual
operation, the floor heating, the screed or the
floor structure could be damaged due to overheating.
● Prior to initial commissioning, set the
maximum temperature limit in the RoCon BF
control unit ([Max T-Flow] parameter) to the
maximum permitted system temperature
prior to starting the emission measurement.
The heat slope is used to adjust the T-HS to the characteristics
of the building independent of the respective outside temperature
(weather-dependent T-HS control, see chap. 3.6.3). Generally
speaking, the steepness of the heating slope describes the ratio
of the T-HS change to the external temperature change.
The heat slope is valid within the limits of the minimum and
maximum temperatures set for the respective heating circuit. The
room temperature measured in the occupied area may differ from
the desired room temperature; these deviations can be kept to a
minimum by installing a room thermostat or a room control.
The control unit is set at the factory in such a way that the heat
slope does not independently adjust itself during operation.
HC Configuration
Accep limit DHW
Heat-Slope
T-Flow Day
Configuration
Setup
System Configuration
Heat-Slope
Configuration
System Configuration
HC Configuration
DHW Configuration
Heat-Slope
HC Configuration
HC Function
Pump Mode
The automatic heat slope adjustment can be activated ([HC
Adaption] parameter) if the outside temperature sensor
(RoCon OT1) and the room control (EHS157034) are connected (see chap. 3.6.3).
Start conditions for automatic heat slope adjustment:
– Outside temperature < 8 °C
– Operating mode is automatic (I or II)
– Duration of the setback period is at least 6 h
Heat-Slope
Fig. 3-16 Manual setting of the heat slope
If no automatic heat slope adjustment is activated, the heat
slope can be manually adjusted by adjusting the [Heat-Slope]
parameter).
Manually adjusting the heat slope
Do not make any corrections to the set values for 1 - 2
days, and then only make them in small increments.
● Deactivate the external heat sources (e.g. stoves, direct
sunlight, open windows).
● Fully open any radiator thermostat valves or actuators.
● Activate "Heating" operating mode.
Approximate setting values:
– Radiators and System 70: 1.4 to 1.6.
– Floor heating: 0.5 to 0.9.
TA
TR
Outside temperature
TV
Room temperature target value
T-HS
Fig. 3-17 Heat slopes
Detailed explanations and possible setting values of this function can be found in
chap. 6.2.
Operating instructions
22
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
3 x Operation
3.6.3 Weather-dependent T-HS control
If the weather-dependent T-HS control is active, the T-HS is automatically determined, depending on the outside temperature
according to the set heat slope. To do this, the outside temperature sensor (RoCon OT1) must be connected.
If, in addition, the room control (EHS157034) is connected to the
Daikin RoCon BF, the target temperatures are controlled according to the weather and room temperature (see
tab. 6-3/tab. 6-18, [Room Influence] parameter).
The activation or deactivation of this function is takes place via
the [HC Function] parameter in the "Configuration"
rotary
switch setting at the "HC Configuration" level.
– [HC Function] parameter = 0: Weather-dependent T-HS control
– [HC Function] parameter = 1: Control according to fixed target
temperature
1. Enter the technician code (see chap. 3.6.1).
 After entering, the "Setup" level is displayed.
2. Use the rotary button to select the [Air Purge] parameter.
3. Confirm the selection with a brief push of the rotary button.
 The setting of the parameter is displayed.
4. Use the rotary button to set the parameter for the function to
"On" and confirm by briefly pressing the rotary button.
 "Air Purge" starts (the 3-way valves move to the middle
position, the heating circulation pump modulates, see
fig. 3-18).
 After the program has ended (approx. 10 min), the Daikin
heat generator is switched to "Standby" operating mode.
With connected mixer module
The adjustment of the heat slope and the activation of the
weather-dependent T-HS control for the assigned heating circuit
are carried out in the same way as described above.
The assigned heating circuit can be operated as a:
a) Mixer add-on 
The outside temperature of the outside temperature sensor
connected to the heat generator is transmitted to the mixer
module over the CAN bus.
or as a
b) Mixer add-on with zone control 
A separate outside temperature sensor (RoCon OT1) must
be connected to the mixer module. The assigned heating circuit is controlled according to the outside temperature relevant for this zone.
With activated terminal function, the mixer module can be operated via the RoCon B1 control unit of the heat generator and
the settings can be made for the assigned heating circuit.
In conjunction with the EHS157034 , the mixer module can also
control the assigned heating circuit completely independently
and independent of the heat generator.
If the "n.a." message is displayed in the rotary switch
setting
, no valid terminal address has been
assigned to the control unit.
If the "n.a." message is still displayed, it may be necessary to
update the device software in order to use the terminal function.
Contact the Daikin Service Team for this.
Detailed explanations and possible setting values of this rotary switch setting can be
found in chap. 6.2.3 and 6.13.2.
Fig. 3-18 Processes of the Air Purge
3.6.4 Air Purge
By activating the Air Purge, the RoCon BF control unit starts a
clearly defined sequence program with start/stop operation of the
integrated heating circulation pump, as well as different positions
of the 3-way switching valves connected to the Daikin heat generator.
5. Set the rotary switch to the "Operating Mode"
position and set the required operating mode (see chap. 3.4).
Detailed explanations and possible setting values of this function can be found in
chap. 6.2.1.
Available air can escape via the automatic vent valve during the
Air Purge and the hydraulic circuit connected to the Daikin heat
generator is evacuated.
The activation of this function does not replace the
correct venting of the heating circuit.
The heating circuit must be completely filled before activating this function.
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
23
3 x Operation
3.6.5 Anti-legionella system
This function is used to prevent bacterial contamination in the hot
water storage tank. If the anti-legionella system function is activated, thermal disinfection is carried out. To do this, the connected hot water storage tank is heated up 1x day or 1x week to
a disinfection temperature. The anti-legionella system function is
active for one hour.
The setting of the parameters for the anti-legionella system is
carried out in the "Configuration"
rotary switch setting at the
"DHW Configuration" level.
With the factory settings, the storage tank is recharged at 00:15
am if the hot water temperature is less than 65 °C at this point of
time.
Option 2
With expert status, reset all customer-specific parameter settings to the factory setting in accordance with tab. 6-1 to
tab. 6-11 in the "Special Level".
1. Enter the technician code (see chap. 3.6.1).
 After entering, the "Setup" level is displayed.
2. Push the Exit button for at least 5 s.
 The "Special Level" menu is displayed.
3. Use the rotary button to select the "Parameter Reset"
program.
4. Execute the program by briefly pressing on the rotary button.
 The respective values are reset to the factory setting.
5. Use the rotary button to select "Return".
WARNING!
There is a risk of scalds at hot water temperatures of more than 60 °C. This is possible when
using solar energy if the anti-legionella system
is activated or if the hot water target temperature is set to more than 60 °C.
● Install scald protection in the hot water distribution line (e.g. VTA32).
The heating of the hot water for disinfection is carried
out independently of the target temperatures for hot
water set by the user or by the heating expert.
A connected circulation pump is automatically switched on
during thermal disinfection.
Detailed explanations and possible setting values of this function can be found in
chap. 6.2.
3.6.6 Resetting to factory setting
If the Daikin heat generator no longer functions correctly and no
other source for the incorrect behaviour can be determined, it
may be appropriate to reset all control settings to the factory settings. There are 3 ways of doing this.
Option 1
With user status, the switching time programs can be reset to
the factory setting in accordance with tab. 3-9 at the "Special
Level".
1. Push the Exit button for at least 5 s.
 The "Special Level" menu is displayed.
2. Use the rotary button to select the "Timeprog Reset" program.
3. Execute the program by briefly pressing on the rotary button.
 The respective values are reset to the factory setting.
6. Confirm the selection with a brief push of the rotary button.
Option 3
If basic changes to the RoCon device are required for the function
within the RoCon system, with expert status the basic configuration can be reset to the delivery state or newly defined.
1. Enter the technician code (see chap. 3.6.1).
 After entering, the "Setup" level is displayed.
2. Use the rotary button to select the "System Config" level.
3. Confirm the selection with a brief push of the rotary button.
 An overview is displayed.
4. Use the rotary button to select the "Delete" program.
5. Confirm the selection with a brief push of the rotary button.
 A restart of the RoCon device is carried out.
 The "No Basic Configuration" message is displayed.
6. Set the rotary switch to the "Info"
position.
 The "Basic Configuration Not Set" message is displayed.
7. Now it is possible to either carry out the settings individually
(a) or to automatically load the factory settings (b).
a) Press the rotary button Briefly.
 The parameter overview of the "Basic Configuration"
level is displayed and the settings can be carried out manually according to tab. 6-16.
b) Switch the Daikin RoCon device off and on again.
 After restarting the RoCon device, a query asks if the
standard configuration should be used. If confirmed with
"Yes", the preset basic configuration is loaded. If "No"
is selected, the settings must be made manually, see a).
Detailed explanations and possible setting values of this function can be found in
chap. 6.12.
After resetting to the factory settings using option 2 or 3, the
system must be adjusted to the installation environment again by
the heating expert and all customer-specific parameters need to
be reset.
4. Use the rotary button to select "Return".
5. Confirm the selection with a brief push of the rotary button.
Operating instructions
24
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
3 x Operation
3.6.7 Screed program
The screed program is used exclusively for the specified drying
of newly created screed for floor heating. Here, the heat generator is operated over several days in accordance with a specified temperature profile (the basis for the preset temperature
profile is the recommendation of the surface heating federal association for screed curing heating).
After entering the technician code in the "Configuration"
rotary switch setting, the temperatures and the duration of the
screed program can be freely set in the [Screed Program] parameter at the "HC Configuration" level.
Procedure in accordance with EN 1264 Part 4:
For anhydrite and cement screeds, the heating circuits
must be leak tested by a water pressure test after completion. The leaktightness must be ensured immediately before
and during the laying of the screed. The height of the test pressure is at least 1.3x the maximum permitted operating pressure.
Suitable measures must be taken if there is a risk of freezing,
e.g. use of antifreeze agents or heating the building. If antifreeze
agents are no longer necessary for the intended operation of the
system, the antifreeze agent must be removed by draining and
rinsing the system with at least 3 changes of the water.
The screed program is a special function and is not interrupted
by any other operating mode. It can only be activated by the
heating expert for the direct heating circuit and/or optionally
connected mixed heating circuits. It must be activated separately
for every heating circuit.
Prior to starting the screed program, the [Room thermostat] parameter must be deactivated.
During a short-term power failure, a previously activated screed function is continued at the point of the
interruption.
After activation of the screed program, all weather-dependent
control functions of the respective heating circuit are switched off.
The respective heating circuit works, as a constant temperature
control regardless of the operating mode (switching times).
t1
t2
tV
Z
An already started screed program can be deactivated at any
time. After ending the screed program, the parameter is automatically set to "Off" and the heating circuit works according to the
currently set operating mode again.
Fig. 3-19 Chronological sequence of the screed program during the
function heating
Function heating
The function heating serves as proof of the production of defect
free work for the heating engineer. A prefabricated heating protocol related to Daikin floor heating can be found in the Internet
portal of Daikin.
In this sense, the function heating (identical with "Heating" in
EN 1264, section 5.2) is not considered as a heating process to
achieve workability of the screed. Generally, a special screed
curing heating and/or mechanical drying is required for this.
The heating of cement screeds should be carried out at the earliest after 21 days and of anhydrite screeds after 7 days at the
earliest in accordance with the specifications of the manufacturer. The first heating begins with a T-HS of 25 °C that must be
maintained for 3 days. Afterwards, the heating is carried out with
the maximum set T-HS for the heating circuit (limited to max.
55 °C), which must be maintained for a further 4 days.
Start temperature 25 °C (38 °C for System 70)
Maximum heating circuit temperature
T-HS
Duration of the screed function in days after starting the function
Screed curing heating
The drying process for the screed cannot be exactly predicted. If
there is a high degree of humidity, sometimes it can stop completely. The drying process can be speeded up by activating the
floor heating (screed curing heating) or measures such as mechanical drying.
Each screed curing heating must be ordered separately by the
client as an extra service in accordance with German construction contract procedures (VOB). The workability of the
screed is a prerequisite for beginning the work of the top floor installer, so that he can produce defect free work.
With standard settings, the combined function and screed curing
heating program can be activated to achieve the required residual moisture in the screed for workability of the screed (see
fig. 3-20). However, the residual moisture of the screed must basically be checked metrologically before the flooring can be laid.
Due to the insulating effect of the DUO heating pipe for the
System 70, the screed function must be carried out at higher temperatures. The temperature profile must be adjusted for this application in the [Screed Program] parameter. For System 70, the
heating begins at a temperature of 38 °C which is maintained for
3 days. The set maximum heating circuit temperature (limited to
70 °C) is then maintained for 4 days.
After the described heating process, it is not yet assured that the
screed has reached the required moisture content for workability
of the screed.
The moisture content in the screed must be checked by measurement prior to laying the surface covering.
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Fig. 3-20 Chronological sequence of the screed program during the
combined function and screed curing heating (for legend, see
fig. 3-19)
More detailed explanations and possible setting values of this function can be found
in chap. 6.2.
Operating instructions
25
3 x Operation
Setting and starting the screed program
The screed program already includes factory default values
which can, however, be individually adjusted.
Configuration
System Configuration
The day on which the screed program is activated is not counted
in the runtime of the program. The 1st day starts at the change of
day at 00:00 am. On the day of activation, the setting of the 1st
program day is used for heating for the remaining time.
● Set the rotary switch to the "Configuration"
position.
 An overview is displayed.
● Use the rotary button to select the "Setup" level.
 An overview is displayed.
● Use the rotary button to select the [Room thermostat]
parameter and check if it has been deactivated (see tab. 6-1).
 Prior to starting the Screed function, the parameter must
be set to "Off".
● Set the Screed function in the system parameters to "On"
(see also fig. 3-21).
 The screed program is activated.
● Check the screed program and set according to the manufacturer specifications for the screed.
– The adjustment range always lies between 0.0 and 65 °C.
– The increment is 1 °C.
Day
Factory setting
Day
Factory setting
1-3
25 °C
10 - 19
55 °C
4-7
55 °C
20
40 °C
8
25 °C
21
25 °C
9
40 °C
22 - 26
-
HC Configuration
DHW Configuration
Configuration
HC Configuration
Setup
HC Function
System Configuration
Pump Mode
HC Configuration
Screed
Screed Program
Tab. 3-10 Screed Program presettings
Screed Program
Screed
Day 1 25 °C
Off
T-HS
Day 1
Screed
Day 1 25 °C
On
T-HS
Screed
Day 1
Day 1 26 °C
Fig. 3-21 Setting the screed program
Operating instructions
26
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
3 x Operation
After the screed program has ended, the RoCon BF control unit
continues to work in the previously set operating mode. If not configured beforehand, the following finishing work is necessary.
a) For connection without room control:
● Set the heating characteristic curve or required T-HS.
b) For connection with room control:
● Activate the room control.
● Set the heating characteristic curve or required T-HS. If
necessary, activate the [Room Influence] parameter and
set the room target temperature.
3.6.8 Relay test
In the event of error messages, heating problems or as part of the
annual maintenance, it may be necessary to check the function
of the internal switching relays and sensors.
● Set the rotary switch to the "Configuration"
position.
 An overview is displayed.
● Use the rotary button to select the "System Configuration"
level.
● Confirm the selection with a brief push of the rotary button.
 An overview is displayed.
● Use the rotary button to select the following parameter:
[Relay Test] (only visible with technician code)
 All relays are deactivated.
 A selection list of all relays is displayed (for the assignment of the relays, see chap. 6.2).
● Use the rotary button to select the relays to be checked.
● Confirm the selection with a brief push of the rotary button.
 A relay is activated.
● Cancellation and jump back by:
– briefly pressing the Exit key or the rotary button
– selecting another menu using the rotary switch.
Detailed explanations and possible setting values of this function can be found in
chap. 6.2.
3.6.9 Settings for optional circulation pump
For greater convenience in draining the water, an optional circulation pump can be switched with the RoCon BF control unit.
There are 2 setting options for this:
a) Separate switching time program (see chap. 3.4.7). Here, the
circulation pump works according to an independent
switching time program.
b) Together with a hot water switching time program. Here, the
circulation pump is controlled in parallel to the operating times
of a hot water switching time program.
Independent of the set switching time program, the energy consumption of the circulation pump can be minimised by operating
it in pulse mode. The [Circl-Pump Interval] parameter sets the duration of operation of the circulation pump within a 15-minute interval.
Use with hot water switching time programs
● Set the rotary switch to the "Configuration"
position.
 An overview is displayed.
● Use the rotary button to select the "DHW Configuration" level.
● Confirm the selection with a brief push of the rotary button.
 An overview is displayed.
● Select the parameter to be set with the rotary button.
– [Circl-Pump DHW]: Setting of whether the circulation
pump is controlled by the active hot water switching time
program ("On") or by the separate switching time program
("Off").
– [Circl-Pump Interval]: Setting of the interval control for
optional circulation pump.
● Confirm the selection with a brief push of the rotary button.
● Set the parameter.
● Confirm the selection with a brief push of the rotary button.
 The circulation pump is controlled by the RoCon BF control unit in accordance with the entered settings.
Possible setting values of this rotary switch setting can be found in chap. 6.2.
3.6.10 Remote control via Internet
The RoCon BF control unit can be connected to the Internet via
an optional gateway (EHS157056). This enables remote control
of the Daikin RoCon BF from mobile phones (by app).
3.6.11 Frost protection function
The integrated heating circulation pump is switched on at an outside temperature below the [T-Frost Protect] parameter value in
order to prevent the heating system from freezing.
In addition, the flow, storage and connected room temperature
sensors are also constantly monitored. If the measured temperature at one of these sensors falls to less than 7 °C (less than
5 °C at room temperature), the antifreeze function is also activated.
If the antifreeze function is active, the display of the RoCon BF
symbol next to the time on the
control unit displays the
standard display.
If the temperature of the heating flow falls to less than 7 °C, the
Daikin heat generator heats until the temperature of the heating
flow reaches at least 12 °C.
The function is ended if the outside temperature rises above the
set [T-Frost Protect] parameter value + 1 K and also there is no
other activation condition.
3.6.12
Heating support
If the heating support function ([HZU] parameter = On) is activated, the energy in the integrated storage tank of the Daikin
GCU compact is used to take over the heating function. If the
storage temperature is sufficiently high, the burner remains inactive.
The minimum value (THZUmin) is calculated as follows:
THZUmin = currently active hot water target temperature [T-DHW
Setpoint] + [TDiff-DHW CH Support] parameter.
Switch-on condition:
Tdhw > THZUmin + 4 K and Tdhw > [T-HS Setpoint] info parameter + 1 K
If the switch-on condition is fulfilled, heat is taken from the
storage tank and this is used to supply the heating system.
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
27
3 x Operation
Switch-off condition:
Tdhw < THZUmin or Tdhw < [T-HS Setpoint] info parameter (see
chap. 3.6.3)
If the switch-off condition is fulfilled, the heating support from the
hot water storage tank is set and the burner takes over the
heating operation.
The [Power BIV] parameter limits the maximum power that can
be removed. The [T vbh1 max] parameter limits the maximum
temperature that can enter the heating system.
3.6.13 Special function: Switching contacts
By setting the [AUX Fct] parameter, the switching conditions for
the potential-free AUX switching contact (toggle switch output A).
This switching contact can be used to control an external heat
generator, for example.
If one of the switching conditions is fulfilled, the potential-free
switching contact is switched after the time set in the [AUX time]
parameter.
AUX switching contact (toggle switch output A) is not switched
if
setting =
0: function deactivated.
AUX switching contact (toggle switch output A) is switched if
setting =
1: storage temperature (Tdhw) ≥ value [T-DHW 1 min] parameter.
2: if an error is pending.
3: outside temperature < [Equilibrium Temp] parameter value.
4: hot water generation heat requirement.
5: room heating heat requirement.
6: room heating or hot water generation heat requirement.
3.6.14
SmartStart function
The SmartStart function was developed to avoid frequent
switching of the burner when there is a low room heating heat requirement.
Here, the burner runtime is recorded after a burner start for room
heating.
If this burner runtime is shorter than the minimum burner runtime
set in the [BST Control] parameter, the SmartStart function is automatically activated. The requirement for room heating is temporarily covered by the heat stored in the storage tank.
If the storage temperature drops so far that a requirement for hot
water generation (Tdhw < (current hot water target temperature [Hysteresis DHW] parameter)) is pending, this takes place at a
greater target value (current hot water target temperature + [Exp
delta WW ] parameter).
The SmartStart function remains active until the next requirement
for hot water generation is pending. This then takes place again
according to the normal control algorithm after which the hot
water generation is ended when Tdhw reaches the current hot
water target value.
If, after a burner start, the burner runtime is longer than the set
minimum burner runtime for room heating, the SmartStart
function is not activated.
The [HT Protect] parameter (see tab. 6-2) limits the raised target
value of the storage temperature.
Operating instructions
28
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
4 x Initial commissioning
4
Initial commissioning
In addition to the commissioning instructions listed in
this chapter, the specific commissioning instructions
listed in the respective installation instructions of the
Daikin heat generator must be complied with.
In many applications, nothing needs to be changed in the basic
settings. The more RoCon system components that are integrated in the RoCon system, the more adjustments that need to
be made during initial commissioning or when extending the
heating system.
The RoCon system offers a very wide range of application and
extension options.
The assignment of the functional IDs is easiest when carried out
via the "Setup Wizard" installation menu. Most IDs can also be
adjusted to the conditions later via parameter settings at the respective parameter levels (see chap. 6).
The individual RoCon system components communicate via the
CAN data bus. For this, the RoCon BE1 circuit boards and the
RoCon B1 control units of the Daikin heat generator, as well as
possibly the optional EHS157034 room station system components and EHS157068 mixer module, are connected with each
other via data bus lines.
These system components must be allocated unique functional
IDs, so that the data exchange and the assignment within the
RoCon system functions without any problems.
a) If no optional RoCon system components are connected
to the Daikin heat generator, only the RoCon BE1 control
panel and the integrated RoCon B1 control unit communicate
with each other in the RoCon system.
 Adaptation of the IDs is not necessary.
 The "Use Standard Config" query displayed during initial
commissioning can be confirmed with "Yes".
b) If optional RoCon system components such as
EHS157034 and / or EHS157068 are connected, adaptation
to the IDs may be necessary.
4.1 Fundamental aspects of the IDs and authorisations in the RoCon system
In the RoCon system, the following functional IDs that are relevant for data exchange of the RoCon system components exist:
ID / Function
Heating circuit ID
System components
Daikin heat generator
(RoCon BE1)
Unique numbering of a heating circuit
in the heating system in the RoCon
EHS157034 room station
system. A maximum of 16 heating circuits can be controlled.
EHS157068 mixer module
Heat generator ID
Unique numbering of a heat generator in the RoCon system.1)
Daikin heat generator
(RoCon BE1)
EHS157068 mixer module
Parameter
Comments
[Unmixed Circ Config] Factory setting = 0
See tab. 6-16
Should not normally be changed.1)
[HC Assignment]
See tab. 6-1
Factory setting = Off
[HC Assignment]
See tab. 6-17
Factory setting = Off
[BUS ID HS]
See tab. 6-16
Adjustment required if different heating circuits are in the system and/or the [MasterRoCon] parameter = On
Must always be adapted to the setting of
the address switch (fig. 4-2).
Factory setting = 0
Should not normally be changed.1)
[Boiler Assignment] Factory setting = 0
See tab. 6-17
Should not normally be changed.1)
Defines the heat generator that supplies
the assigned heating circuit with heat.
Terminal ID
Daikin heat generator
(RoCon BE1)
[Terminaladress]
See tab. 6-1
Unique numbering of a RoCon B1 or
EHS157034 control unit from which a
heat generator and/or mixer module
can be remote controlled in the
RoCon system.
EHS157034 room station
[Terminaladress]
See tab. 6-1 or
The authorisation for remote control
tab. 6-17 - depending
can be allocated to up to 10 control
on the set heating cirunits in the RoCon system. If remote
cuit
ID and the current
control in the RoCon system is to be
operating mode
possible, the control unit must be allocated the ID "0".
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Factory setting = Off
The value should be set to "0" if at least 1
mixer module is connected in the RoCon
system, and the mixer circuit is to be operated from the heat generator.
Factory setting = Off
The value must be set to a unique numerical value in the RoCon system if the
room station system components are to be
remotely controlled using a valid device ID.
Operating instructions
29
4 x Initial commissioning
ID / Function
Device ID
Unique numbering of a heat generator or mixer module in the RoCon
system.
System components
Parameter
Daikin heat generator
(RoCon BE1)
[BUS ID HS]
See tab. 6-16
Up to 16 device numbers can be allo- EHS157068 mixer module
cated.
[HC Assignment]
See tab. 6-17
These device numbers are detected
during a [Bus - Scan] and are displayed for identification of a remotely
controlled device.
Comments
Identical to heat generator detection.
The value must not be the same as the
heating circuit ID of a mixer module in the
RoCon system.
Identical to the heating circuit ID.
The value must not be the same as the
heat generator ID of the Daikin heat generator in the RoCon system.
The value must be the same as the setting
of the address switch (fig. 4-2).
Tab. 4-1 Functional IDs in the RoCon system
1)
A maximum of 8 heat generators can be connected in the RoCon system via the CAN data bus. Several heat generators integrated in the heating installation must
be regarded as a special application. If necessary contact a Daikin service technician.
If several control units are incorporated in the RoCon system of a
heating installation, additional parameter settings are relevant for
this and can be used to set the individual functions and parameters using the appropriate authorisations.
For the EHS157034 room station
–
–
[RoCon U1 assign] parameter:
– The setting = "Living Room" can be used to influence the
heating circuit defined by the set heating circuit ID.
– The setting = "Mix Valve" can be used to carry out all the
settings for the mixer circuit defined by the set heating circuit ID.
[Master-RoCon] parameter:
If the heating circuit ID for the direct heating circuit of a Daikin
heat generator is set, the master RoCon function can be activated via the setting = "On". Thus, the hot water functions of
the Daikin heat generator can be operated in addition to the
heating circuit functions with this room station.
The activation of the master RoCon function is useful for heating systems that are constructed of a Daikin heat generator
only (without heating circuit extension) and a room station,
and that are to be operated primarily via the room station (see
following information).
If the master RoCon function is activated, the operating mode of the heat generator is set via the room
station, and this is shown on the display.
The settings on the room station are transferred to the heat
generator, but not vice versa. The room station has priority.
If the [Summer] operating mode is set on the room station, for
example, and later the [Heating] operating mode is set on the
control unit of the Daikin heat generator, no heating circuit requirement is generated, as the direct heating circuit (which is
assigned to the room station via the heating circuit ID) is still
in the [Summer] operating mode. The change in operating
mode must therefore be carried out at the room station.
If the terminal function is to be used in the heating system, the
terminal ID = 0 must be allocated to a control unit.
4.2 Operating support during initial
commissioning and during system
extensions
When a Daikin heat generator or a EHS157034 room station is
switched on for the first time, normally the opportunity of setting
the user language is offered first.
Afterwards, the Daikin heat generator is queried "Use Standard
Config?". This query can normally be answered with "Yes".
Only in special applications (e.g. several heat generators in the
RoCon system) should the answer be "No". In this case, the
"Basic Configuration" parameter level will be offered in order to
set the necessary adaptations (see tab. 6-16).
In the case of the EHS157034 room station, after setting the user
language, the "Setup Wizard" installation menu appears.
Setup Wizard
Fig. 4-1
"Setup Wizard" display
The parameters required for the definition of the function, the authorisation and the ID of the room station in the RoCon system
are queried and checked for plausibility.
This prevents duplicate device and terminal IDs being set.
Therefore, it is recommended that you use this installation menu
when extending or making changes to the RoCon system of the
heating installation. To do this, a room station already integrated
in the heating installation must first be reset.
1. Enter the technician code (see chap. 3.6.1).
For heating systems with heating circuit extensions, it is recommended not to activate the master RoCon function (setting
= "Off") and to use the terminal function instead.
For all RoCon B1 and EHS157034 control units
–
[Terminaladress] parameter:
As soon as a control unit is assigned to a terminal ID (all settings with the exception of "Off"), the control unit can be used
to activate the terminal function.
After carrying out the [Bus - Scan], all the system components
integrated in the RoCon system can be remotely controlled
using a valid device ID (caretaker authorisation).
Operating instructions
30
2. Push the Exit button for at least 5 s.
 The "Special Level" menu is displayed.
3. Use the rotary button to select the "RoCon B1/U1 Reset"
program.
4. Execute the program by briefly pressing on the rotary button.
 The "Setup Wizard" installation menu starts.
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
4 x Initial commissioning
4.3 Putting the Daikin heat generator into
operation
4.4 Putting optional RoCon system components
into operation
A precondition for initial commissioning is the completion of all
preparatory installation work in accordance with the installation
and maintenance instructions for the Daikin heat generator.
4.4.1
● Switch on the power supply to the Daikin heat generator.
 After the start phase, the operating language selection is
displayed.
● Use the rotary button to select the desired language.
The operating language can be changed again at any
time.
● Confirm the selection with a brief push of the rotary button.
 The "Use Standard Config?" message is displayed.
● Confirm the default "Yes" by briefly pressing on the rotary
button (see also chap. 4.2).
 The basic configuration of the RoCon device is loaded.
 The "Starting Up" message is displayed.
 The "Initialization" message is displayed.
 The standard display for the current rotary switch setting
is shown.
● Adjust settings related to the configuration of the heating
system on the RoCon device (see chap. 3.6).
The EHS157068 has no control unit of its own. For configuration
and operation, it must be connected to a RoCon control unit installed in the heat generator or an EHS157034 via a CAN bus
line.
In conjunction with a room station, the mixer module
can also be operated as a free-standing heating circuit
controller.
To operate the mixer module directly via the RoCon B1 control
unit of the Daikin heat generator, it must have a terminal ID assigned to it and the terminal function must be activated (see
chap. 3.4.9).
After selection and confirming an external device in the rotary
switch setting
, the terminal function for this device is activated and the associated standard display for this device is
shown on the display.
The operating component is then in terminal operation.
The local control unit functions as a remote control for the external device. In this case, all the control functions are performed
and saved 1:1 as on the external device.
If the "n.a." message is displayed in the rotary switch
setting
, no valid terminal ID has been assigned to
the control unit until now.
4.3.1 Assigning the terminal ID on the RoCon B1
control unit to the Daikin heat generator
If several control units are connected in the RoCon
system via the data bus, it is important to note that the
[Terminaladress] parameter = 0 must be set for a heat
generator.
Make sure not to assign a duplicate value as the setting of the
[Terminaladress] in the RoCon system.
● Enter the technician code (see chap. 3.6.1).
 After entering, the "Setup" level is displayed.
● Use the rotary button to select the [Terminaladress]
parameter.
● Confirm the selection with a brief push of the rotary button.
● Within the display, use the rotary button to set the unique
terminal address.
For reasons of clarity, this control unit must be assigned the
value = 0.
● Confirm the selection with a brief push of the rotary button.
 The change has been accepted. Jump back to the previous display.
Detailed explanations and possible setting values for this rotary switch setting can
be found in chap. 6.2.1.
Mixer module EHS157068
If the "n.a." message is still displayed, it may be necessary to
update the device software in order to use the terminal function.
Contact the Daikin Service Team for this.
A unique device ID (≥ 1) must be set on the address switch (see
fig. 4-2) for the heating circuit to be controlled by this mixer
module, which must be synchronised with the [HC Assignment]
parameter of the mixer module (see tab. 4-1]).
Fig. 4-2
Setting the device ID for the EHS157068 mixer module
All settings and operating steps for this heating circuit are performed in the same way as those for the direct heating circuit. An
overview of the available parameters and their settings can be
found in chap. 5.13.
The current operating status can be determined directly on the
EHS157068 mixer module (see fig. 4-3).
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
31
4 x Initial commissioning
All the operating steps for the assigned heating circuit
after initial commissioning are performed in the same
way as those for the RoCon B1 operating element of
the Daikin heat generator.
However, not all functions (e.g. manual operation, resetting
errors) of the Daikin heat generator can be activated with the
room station.
1
LED red
- Flashing: Internal error 
(error code is communicated to the relevant control unit over the CAN bus)
- To: Undervoltage of the internal clock after a power failure (>10 h)
2
LED green
- To: Display during operation, mixer module
switched on
3
LED green
- To: CAN communication established
4
LED green
- To: Mixer circuit pump switched on
5
LED green
- To: Mix valve "OPEN" is activated
6
LED green
- To: Mix valve "CLOSED" is activated
Fig. 4-3
Explanation of symbols for EHS157068 status displays
4.4.2 EHS157034
A: Configuration for the "Living Room" setting
● Confirm the "Living Room" setting by briefly pressing the
rotary button.
 Setting of the heating circuit ID ([HC Assignment] parameter) is displayed.
● Use the rotary button to select the associated heating circuit
in the [HC Assignment] parameter.
● Confirm the selection with a brief push of the rotary button.
 Setting of the terminal ID ([Terminaladress] parameter) is
displayed.
● Use the rotary button to set the [Terminaladress] parameter.
● Confirm the selection with a brief push of the rotary button.
 Standard display is shown (see fig. 4-4).
room station
The EHS157034 can be set as a:
a) remote control unit of the Daikin heat generator,
b) a mixer circuit operating unit (as a mixer circuit extension or
as a freestanding mixer circuit controller),
c) room thermostat for the Daikin heat generator,
d) remotely controlled unit for the entire RoCon system (with terminal function activated).
The room station must be connected to a Daikin heat generator
in which a RoCon control unit is installed or a EHS157068 mixer
module via a CAN bus line. No separate mains supply is necessary for the room station.
Sequence for initial commissioning (see also
chap. 4.2)
● Set the rotary switch on the EHS157034 room station to the
position.
"Info"
● Switch on the current supply of the associated Daikin heat
generator.
 After the start phase, the operating language selector is
displayed on the EHS157034 room station.
● Use the rotary button to select the desired language.
The operating language can be changed again at any
time.
● Confirm the selection with a brief push of the rotary button.
 The "Setup Wizard" message is displayed.
● Use the rotary button to set the desired operating function for
the room station.
– "Living Room": Operating function, see a), c), d)
– "Mix Valve": Operating function, see b)
 Depending on the selected application, the further configuration is based either on A or B in the following sections.
Operating instructions
32
1
2
3
Date
Time
Current room temperature
Fig. 4-4
4
5
Current outside temperature
Operating mode active for
the assigned heating circuit
Standard EHS157068 - "Living Room" display
 The settings on the EHS157034 room station are only
valid for the assigned heating circuit (except if the terminal
function is active).
B: Configuration for "Mix Valve" setting
● Confirm the "Mix Valve" setting by briefly pressing the rotary
button.
 Setting of the heating circuit ID ([HC Assignment] parameter) is displayed.
● Use the rotary button to set the [HC Assignment] parameter.
This parameter must be identical to the setting of the address
switch in the mixer module (see fig. 4-2), that is allocated to
the EHS157034 room station.
● Confirm the selection with a brief push of the rotary button.
 Setting of the terminal ID ([Terminaladress] parameter) is
displayed.
● Use the rotary button to set the [Terminaladress] parameter.
 Standard display is shown (see fig. 4-5).
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
4 x Initial commissioning
1
2
3
4
Display date
Status display: Screed function active
Status display: Expert login
Display time
Fig. 4-5
5
6
7
Current T-HS of the mixer
circuit
Current outside temperature
Operating mode setting for
the assigned heating circuit
Standard EHS157068 - "Mix Valve" display with example of
the status displays
In the "Mix Valve" setting, the room sensor of the
EHS157068 is deactivated.
4.4.3
Allocating the EHS157068 mixing module to
a heat generator
If just 1 heat generator is integrated in the RoCon system, adaptation of the heat generator ID is not necessary (see tab. 4-1).
If adaptations need to be made, the value of the [Boiler Assignment] parameter (see chap. 6, tab. 6-1) must be set to the
same value as the heat generator ID of the Daikin heat generator
that is intended to supply the mixer circuit of this mixer module.
4.4.4 Master RoCon function
Each EHS157034 room station whose heating circuit ID is set to
a direct heating circuit can be assigned to the master RoCon
function.
● Enter the technician code (see chap. 3.6.1).
 After entering, the "Setup" level is displayed.
● Use the rotary button to select the [Master-RoCon]
parameter.
● Confirm the selection with a brief push of the rotary button.
 The setting of the parameter is displayed.
● Use the rotary button to set the parameter for the function to
"On" and confirm by briefly pressing the rotary button.
All settings on the EHS157034 room station act in the same
way as settings on the RoCon B1 control unit of the assigned
heat generator.
As a result, the functions for hot water generation can also be remotely operated from the room station.
Since, in this setting, the RoCon B1 control unit has control over
the assigned heating circuit, the settings made on the control unit
of the Daikin heat generator only have an effect on the heat generator, but not on the heating circuit (see chap. 4.1).
4.4.5 Caretaker function
The caretaker function equates to the terminal function (see
chap. 3.4.9 and chap. 4.1 under the [Terminaladress] parameter).
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
33
5 x Parameter overview
5
Parameter overview
5.1 For first commissioning or resetting to factory settings
The parameters listed in this section can only be
accessed when the device is commissioned for the first
time or if it is fully reset.
During initial commissioning:
After resetting to factory settings:
● Rotary switch setting: Info
● Resetting to factory settings.
(see chap. 3.6.6 - Option 3)
● Rotary switch setting: Info
● Switch on the power supply to the device and switch on the
main switch.
Language
Use
Standard Config
Yes
No
Basic Configuration
Boiler Function
Unmixed Circ Config
BUS ID HS
Time Master
System Config
Tab. 5-1 "Basic Configuration" parameters
Operating instructions
34
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
5 x Parameter overview
5.2 After first commissioning/After successful basic configuration
5.2.1 Rotary switch setting: Configuration
Setup
System Configuration
LCD Contrast
Burner data reset
LCD Brightness
Power BIV
LCD Illum Time
TDiff-DHW CH Support
Language
Equilibrium Temp
Date
HT Protect
Time
Exp delta WW
Keylock Function
BST Control
Access Rights
AUX Fct
RoCon U1 assign
AUX time
Master-RoCon
T-DHW 1 min
HZU
Delta-T CH
Room thermostat
Max T-HS
MF 1 Config
max hysteresis
Air Purge
Hysteresis time
PWM Config
HS off time
Max Perform Pump
Min Perform Pump
MaxModgrad DHW
MaxModgrad Heating
Sensor Config
Outside Config
Min Pressure
Outside Temp Adap
Storage Config
Max Pressure
Terminaladress
Exhaust Config
Set Point Pressure
System Config
MixerConfig
Max Pressuredrop
HC Assignment
Pressure Config
T-Limit Exhaust
Relay Test
HC Configuration
HC Function
DHW Configuration
Expert Config
Circl-Pump DHW
Pump Mode
Max Flow Gradient
Circl-Pump Interval
T-Outside lim day
Max In/Out Diff
Anti-Legionella day
T-Outside lim night
Dt Reverse
Anti-Legionella time
Heat-Slope
Burner Starts
Anti-Legionella temp
Room Influence
Burner Oper Time
DHW Relief
T-Room Adj
Parallel DHW
T-Flow Day
T-HS DHW
T-Flow Night
Hysteresis DHW
Max T-Flow
Lambda-Gx
Gas type
T-Return
Max DHW loading time
Min T-Flow
Corr qGas start
IO-SP
DHW Off Time
HC Adaption
100% Calibration
IO-AV
DHW Followup
T-Frost Protect
Corr power start
ConV
CL - Offset CES
ConF
BCCRe-Update
IO-BV
IgtoCal
Screed
Error Code
IO-CalMax
Lerr
Screed Program
Q-SetpointRoCon
IO-Comp
PLErr
Q-ActualValueRoCon
IO-S
Burner Starts
T-HS
FI-T
Burner Oper Time
Insulation
Forced Performance
Tab. 5-2 Parameters in the "Configuration" rotary switch setting
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
35
5 x Parameter overview
5.2.2 Rotary switch setting: DHW Reheating
5.2.9 Rotary switch setting: Info
1x Hot Water
Overview
DHW Reloadtime
Water Pressure
Tab. 5-3 Parameters in the "DHW Reheating" rotary switch setting
T-HS
T-HS Setpoint
5.2.3 Rotary switch setting: Operating Mode
T-Outside
Mode:
Stat:
RT:
TV:
TVBH:
TR:
Pump:
Mix1:
Mix2:
tDHW:
TA:
V:
(see also chap. 3, 
fig. 3-5)
Standby
T-DHW
Reducing
T-DHW Setpoint
Heating
T-Return
Desired Output
Summer
Flow Rate
HS type
Automatic 1
T-HC
Runtime Pump
Automatic 2
T-HC Setpoint
Burner Oper Time
T-Exhaust
Mixer Position
Burner
Qch
Gas Valve 1
QWP
T-Room 1 Setpoint
Position 3UV
Qdhw
T-Room 2 Setpoint
Status HS pump
Sw Nr B1/U1
T-Room 3 Setpoint
Burner Starts
Sw Nr Controller
Control Deviation
Sw Nr FA
Tab. 5-4 Parameters in the "Operating Mode" rotary switch setting
5.2.4 Rotary switch setting: Set Temp Day
Tab. 5-5 Parameters in the "Set Temp Day" rotary switch setting
Tab. 5-10 Parameters in the "Info" rotary switch setting
5.2.5 Rotary switch setting: Set Temp Night
5.2.10 Exit key: Special function
T-Reduced
Emission Measurement
T-Absence
Manual Operation
Tab. 5-6 Parameters in the "Set Temp Night" rotary switch setting
5.2.6 Rotary switch setting: DHW Set Temp
STL Test
Res Emission Mon
T-DHW Setpoint 1
FA failure
T-DHW Setpoint 2
Protocol
T-DHW Setpoint 3
Delete message
RoCon B1/U1 Reset
Tab. 5-7 Parameters in the "DHW Set Temp" rotary switch setting
5.2.7 Rotary switch setting: Time Program
Parameter Reset
Timeprog Reset
Return
Party
Away
HC Program 2
Vacation
DHW Program 1
Holiday
DHW Program 2
HC Program 1
Circulation Time
Tab. 5-11 Parameters at "Special function" level
Tab. 5-8 Parameters in the "Time Program" rotary switch setting
5.2.8 Rotary switch setting: Remote Param
Bus - Scan
No selection
Contr BM1/BE1 #1
Mix Valve #0
Tab. 5-9 Parameters in the "Remote Param" rotary switch setting
Operating instructions
36
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
5 x Parameter overview
5.3
Parameter levels for the EHS157068 mixer module
5.3.1 Rotary switch setting: Info
5.3.5 Rotary switch setting: DHW Set Temp
See chap. 5.2.9.
No function.
5.3.2 Rotary switch setting: Operating Mode
5.3.6 Rotary switch setting: DHW Reheating
No function.
See chap. 5.2.3.
5.3.7 Rotary switch setting: Time Program
5.3.3 Rotary switch setting: Set Temp Day
See chap. 5.2.7.
See chap. 5.2.4.
5.3.8 Rotary switch setting: Remote Param
5.3.4 Rotary switch setting: Set Temp Night
See chap. 5.2.8.
See chap. 5.2.5.
5.3.9 Rotary switch setting: Configuration
Setup
Mixer Config
LCD Contrast
HC Function
LCD Brightness
Pump Mode
LCD Illum Time
T-Outside lim day
Language
T-Outside lim night
Date
Heat-Slope
Time
Room Influence
Keylock Function
T-Room Adj
Access Rights
T-Flow Day
RoCon U1 assign
T-Flow Night
Master-RoCon
Max T-Flow
PWM Config
HC Adaption
T-Frost Protect
Insulation
Forced Performance
Start T-Out Cooling
Max T-Out Cooling
Min Perform Pump
Max Perform Pump
Sensor Config
Outside Config
Outside Temp Adap
Flow Temp Config
Terminaladress
Boiler Assignment
HC Assignment
T-Flow Cooling start
T-Flow Cooling max
Min T-Flow Cooling
T-Flow Cooling
Cooling Setpoint adj
Relay Test
Screed
Screed Program
No function when connected to oil and gas-fired heating units. 
(Only applicable if the assigned heat generator has a cooling function.)
Tab. 5-12
Parameters in the "Configuration" rotary switch setting
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
37
6 x Parameter settings
6
Parameter settings
6.1 Explanation of the parameter tables
The parameter tables listed in chap. 6.2 to 6.13 include compact
information on all parameters, which is available in the respective
rotary switch setting on the control unit (1st menu level,
2nd menu level).
BE
Access right for the operator
HF
Access authorisation with technician code
In the event of different information in the BE and HF
columns, login as an expert must be carried out prior to
selecting the parameter level in order to obtain the status
entered in the HF column (see chap. 3.6.1).
In addition to the parameter designations, the tables contain details of the setting ranges, factory settings, setting options or
setting step distances and brief function explanations.
In addition, they provide explanation of the access rights for operation of the control unit. The following abbreviations are used
for corresponding labelling:
Status:
N
Not visible
E
Visible and configurable
S
Visible
6.2 Rotary switch setting: Configuration
6.2.1 "Setup" level
Sublevel
Parameter
Description
Access
BE
HF
Setting range
Min / Max
Factory
setting
Increment
LCD Contrast
Display contrast
E
E
1-10
4
1
LCD Brightness
Brightness of the display
E
E
0-100 %
50 %
10 %
LCD Illum Time
Lighting duration of the display
E
E
5-120 s
30 s
1s
Language
National language of the display texts on the control unit
E
E
German
English
French
Dutch
Italian
Spanish
Portuguese
German
1
Date
Current date in day/month/year format. The current day of the week is calculated automatically from the date.
E
E
Time
Time in hours/minutes format.
E
E
Keylock Function
Release of the key lock function:
Off: Key lock cannot be activated.
On: Key lock can be activated with the rotary button (see chap. 3.1).
E
E
Off
On
Off
-
Access Rights
See chap. 3.6.1.
E
E
RoCon U1 assign
Display only on connected
room station:
Function of the EHS157034 room station in the CAN data bus system:
Living Room: Control unit for the heating circuit allocated in the [HC Assignment] parameter.
Mix Valve: Mixer circuit operating unit (as mixer circuit extension or as a free-standing
mixer circuit control unit)
N
E
Living Room,
Mix Valve
Living Room
-
N
E
Off
On
Off
-
In addition to the above-mentioned functions, the room station can basically be used as
a remote control unit of the Daikin heat generator and of the overall RoCon system (with
activated terminal function) (see chap.. 4.1 and 4.4.2).
Master-RoCon
Display only on connected
room station:
Setting of the master RoCon function
Off: Deactivated
On: Function active
For every EHS157034 room station whose heating circuit ID is set on a direct heating
circuit, the master RoCon function can be activated (see chap. 4.4.4). Several room stations with active master RoCon function in the system are possible, but only one room
station which is assigned to the same heat generator.
All settings on the EHS157034 room station work for activated master RoCon function
as settings on the RoCon B1 control unit of the assigned heat generator. As a result, the
functions for hot water generation can also be remotely operated from the room station.
HZU
Off: No heating support from the heat accumulator
On: Heating support function active (see chap. 3.6.12)
N
E
Off
On
Off
-
Room thermostat
Configuration of a room thermostat with potential-free contacts on a J16 connection of
the heat generator.
Off: Deactivated
On: Evaluation of the switching contact (only if none of the "Standby", "Summer", "Vacation", "Holiday", "Emission Measurement" or "Screed" operating modes is active):
- Closed contact: Operating mode is switched to "Heating".
- Open contact: Switching to previously active operating mode.
N
E
Off
On
Off
-
Operating instructions
38
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Sublevel
6 x Parameter settings
Parameter
Description
Access
BE
HF
Setting range
Min / Max
Factory
setting
Increment
MF 1 Config
Configuration of the multi-function output (230 V, J14 connection):
0: The output is without function.
1: Header pump – The output becomes active as soon as a system heating circuit reports
a heat requirement to the heat generator.
2: Circulation pump – The output is activated either after the time program of the circulation pump or after the time program of the hot water generation, depending on the parametrisation (see chap. 3.6.9).
3: Feeder pump – The output becomes active as soon as a heat requirement is pending
for the direct heating circuit of the heat generator.
N
E
0-3
2
1
Storage Pump
: Configuration of the storage charging circuit:
1: The hot water loading is carried out using a separate pump.
2: The hot water loading is carried out using a switching valve.
N
E
1-2
2
1
Air Purge
Activation of the automatic venting of the hydraulic circuit to which this Daikin heat generator is connected (see chap. 3.6.4).
Off: Deactivated
On: Start of the Air Purge
N
E
Off
On
Off
-
Min Perform Pump
Lower limit for modulation of the pump power
N
E
0 - 100 %
50 %
1%
Max Perform Pump
Upper limit for modulation of the pump power
N
E
0 - 100 %
100 %
1%
Outside Config
Configuration of the outside temperature sensor:
Off: No sensor evaluation
On: Sensor evaluation activated (if no outside temperature sensor is connected, an error
message is generated.)
N
E
Off
On
On
-
Storage Config
Configuration of the hot water generation:
Inactive: No function for hot water generation.
Sensor: Function for hot water generation is activated. A storage temperature sensor is
evaluated for hot water generation (if no storage temperature sensor is connected, an
error message is generated).
Thermostat: Function for hot water generation is activated. A thermostatic switch
(ON/OFF) is evaluated for hot water generation, where an "open terminal" is evaluated
as "not required".
N
E
Inactive
Sensor
Thermostat
Inactive
-
Exhaust Config
Configuration of the flue gas temperature sensor:
Off: No sensor evaluation
On: Sensor evaluation activated (if no flue gas temperature sensor is connected, an error
message is generated.)
N
E
Off
On
On
-
MixerConfig
: Configuration of the tV2 internal mixer sensor for control of the heating support.
Off: No sensor evaluation; heating support deactivated
On: Sensor evaluation activated (if no mixer sensor is connected, an error message is
generated).
N
E
Off
On
On
-
Pressure Config
Configuration of the sensor for detection of the water pressure of the system:
Off: No sensor evaluation
On: Sensor evaluation activated (if no pressure sensor is connected, an error message
is generated.)
N
E
Off
On
On
-
Outside Temp Adap Individual adjustment for the measured value of the outside temperature relevant for the
control unit.
N
E
-5.0 - 5.0 K
0.0 K
0.1 K
Terminaladress
Setting of the terminal ID of the control unit for system access. The set value must be
unique throughout the entire system. Confirmation of this parameter with the rotary button effects new initialisation of the control unit.
All settings except for "Off" authorise the user of the control unit to activate the terminal
function and thus to operate all RoCon system components with a valid device ID (see
chap. 3.4.9 and 4.1).
N
E
Off, 0 - 9
0
1
System Config
See chap. 6.12
N
E
Inactive,
Active,
Delete
Active
-
HC Assignment
Display only on connected
room station:
Setting of the heating circuit ID for the room station (see chap. 4.1). This parameter determines which heating circuit should be operated with this value.
The direct heating circuit of the Daikin heat generator is set to heat circuit ID "0" as standard (see tab. 6-16, [Unmixed Circ Config] parameter).
N
E
Mix
3UV
Mix
-
PWM Config
Sensor Config
:Sensor
Tab. 6-1 Parameters in the "Configuration" rotary switch setting, "Setup" level
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
39
6 x Parameter settings
6.2.2 "System Configuration" level
Parameter
Burner data reset
Power BIV
Description
Resetting the [Burner Oper Time] and [Burner Starts] parameters.
Off: No function
On: After confirmation with the rotary button, the values are set to "0" and the parameter is automatically set to "Off".
: Setting limits the capacity of the heating support.
TDiff-DHW CH Sup: If the parameter [HZU] = On, the heating support function is active provided the hot water
port
storage temperature ≥ (set value + current hot water target temperature).
Access
Setting range
Min / Max
Factory
setting
Increment
E
Off
On
Off
-
N
E
3 - 40 kW
15 kW
1 kW
N
E
2 - 15 K
5K
1K
BE
HF
N
Equilibrium Temp
See chap. 3.6.13.
E
E
-15 - +35 °C
0 °C
1K
HT Protect
Setting determines the maximum permitted storage temperature for the SmartStart function, for which hot water generation is carried out to an increased target value (see [Exp delta
WW ] parameter).
Off: Hot water distribution system installed without scald protection. The excessive target value
of the hot water generation is limited to 60 °C.
On: Hot water distribution system with scald protection installed. The excessive target value for
hot water generation is limited to 85 °C.
N
E
Off
On
Off
-
Exp delta WW
Setting determines the temporary excessive increase of the hot water target temperature
over the current target value for the SmartStart function.
N
E
0 - 30 K
0
1K
BST Control
Setting determines the minimum burner runtime for automatic activation of the SmartStart
function.
Off: No SmartStart function
10 - 600 s: If the burner runtime after a burner start at room heating is shorter than the set value, the SmartStart function is activated.
N
E
Off
0 - 600 s
Off
1s
AUX Fct
See chap. 3.6.13.
N
E
0-6
0
1
AUX time
Delay time in s. AUX contact switches if the switching condition (see [AUX Fct] parameter) is
longer than the set time.
N
E
0 - 600 s
120 s
5s
T-DHW 1 min
Hot water temperature switching threshold for AUX contact (see [AUX Fct] parameter).
N
E
20 - 85 °C
50 °C
1 °C
N
E
2 - 20 K
15 K
1K
Delta-T CH
: Set temperature difference for room heating (tV2 - tR)
Max T-HS
Defines the setting limit of the maximum temperatures in the heat generator (limit of [Max TFlow]).
N
E
30 - 90 °C
85 °C
1 °C
max hysteresis
Defines the maximum boiler hysteresis. The heat generator is switched off if the temperature
of the heat generator exceeds the target value by the set value.
N
E
2 - 20 K
10 K
1K
Hysteresis time
Defines the runtime for reducing the boiler hysteresis. The boiler hysteresis is reduced during
the set time by the set value of the maximum hysteresis to a value of 2.0 K. If the hysteresis
time is set to 0, the heat generator is controlled with the fixed hysteresis set in the [max hysteresis] parameter.
N
E
0 - 30 min
4 min
1 min
HS off time
Defines the restart lock time of the burner in heating operation. It is intended to prevent high
cycling (burner on/off) during low heat consumption (e.g. transition period) and reduce the
amount of burner starts. If the burner is switched off in heating operation because the boiler
temperature has exceeded the target value + hysteresis, the blocking time is started.
Even though a possible requirement is still pending (boiler temperature has undercut the target
value), the burner does not switch on until the blocking time has elapsed. A hot water requirement is operated without delay and sets the current value of the blocking time to "0", where a
simultaneously pending heating requirement can be operated directly after the hot water generation.
N
E
Off
1 - 30 min
5 min
1 min
MaxModgrad DHW
Maximum modulation level. Limits the maximum burner power during hot water generation.
N
E
20 - 100 %
100 %
1%
N
S
-
-
-
E
20 - 100 %
100 %
1%
MaxModgrad Heating
Maximum modulation level. Limits the maximum burner power in heating operation during a
heat requirement.
N
-
-
-
Min Pressure
Defines the minimum water pressure.
Pressure monitoring function (only with activated pressure sensor, [Pressure Config]=On, see
tab. 6-1): If the measured value undercuts the set value, the heat generator is switched off and
an error message is generated.
N
E
0.1 - 5.0 bar
0.5 bar
0.1 bar
Max Pressure
Defines the maximum water pressure.
Pressure monitoring function (only with activated pressure sensor, [Pressure Config]=On, see
tab. 6-1): If the measured value exceeds the set value, a warning message is generated.
N
E
0.1 - 5.0 bar
3.0 bar
0.1 bar
Set Point Pressure
Defines the target water pressure.
Pressure monitoring function (only with activated pressure sensor, [Pressure Config]=On, see
tab. 6-1): If the measured value undercuts the set value by more than the value set in the [Max
Pressuredrop] parameter, a warning message is generated.
N
E
0.1 - 5.0 bar
0.9 bar
0.1 bar
Max Pressuredrop
Defines the maximum acceptable pressure loss in the heating system.
Pressure monitoring function (only with activated pressure sensor, [Pressure Config]=On, see
tab. 6-1): If the measured value undercuts the value set in the [Set Point Pressure] parameter
by more than the set value, a warning message is generated.
N
E
0.1 - 5.0 bar
0.5 bar
0.1 bar
T-Limit Exhaust
: Flue gas limit temperature of the heat generator.
If the measured value exceeds the set value, a warning message is generated.
The burner is released again if the measured value has fallen below the set value by more than
10 K.
Locking fault: If the measured value exceeds 118 °C, the burner is switched off and an error
message is generated. The burner is released again if the measured value has fallen below
108 °C. If this case occurs 5x in an hour, the burner is switched off with locking and a fault message is generated.
The burner only starts operating again if the fault has been manually unlocked. To do this, in
the event of a fault, a reset parameter is added in this parameter level, which must be set to
"On" and confirmed.
N
E
0 - 120 °C
105 °C
1 °C
Operating instructions
40
N
S
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
6 x Parameter settings
Parameter
Relay Test
Description
Manual control of individual relays for test purposes. After confirmation of this parameter with
the rotary button, the list of relays 1 - 9 is displayed with a checkbox on the display. For selection and confirmation of a relay with the rotary button, a tick is placed in the checkbox and the
respective relay is activated. Multiple selection is possible.
Relay 1: Output J1 (internal heating circulation pump),
output pump
Relay 2: Output J14 (circulation pump),
Mix valve "Open"
Relay 3: Contact A on output J2 (3UVB1 switching valve),
mix valve "Closed"
Relay 4: Contact B on output J2 (3UVB1 switching valve)
Relay 5: Output J12, 3UV DHW switching valve, "Closed"
Relay 6: Output J12, 3UV DHW switching valve "Open"
Relay 7: Connection J3 (potential-free relay: Closer B-B1) - AUX
Relay 8: Connection J3 (potential-free relay: Changer A-A1/A-A2) - AUX
Relay 9: Output J10 (A1P power supply)
*
Access
BE
HF
N
E
Setting range
Min / Max
Factory
setting
Increment
-
:
When activating relay 3, relay 4 is switched on at the same time. When deactivating relay 4, relay 3 is deactivated at the same time.
Tab. 6-2 Parameters in the "Configuration" rotary switch setting, "System Configuration" level
Depending on the version, individual information parameters are displayed that are not described in
tab. 6-2. For this, see tab. 6-14.
6.2.3 "HC Configuration" level
Parameter
Description
Access
BE
HF
Setting range
Min / Max
Factory
setting
Increment
HC Function
Various different functionalities can be assigned to the heating circuit.
0: Weather-dependent T-HS control
1: Regulation to a fixed set flow value, depending on the heating or setback mode
N
E
0-1
0
1
Pump Mode
Setting of the operating mode of the internal circulation pump.
0: Standard circulation pump switching (weather/room dependent)
1: Circulation pump switching according to heating limits (optional room thermostat shutdown
works additionally).
2: Circulation pump switching according to the heating program
3: Circulation pump switching in the continuous operation
N
E
0-3
1
1
T-Outside lim day
Only if [Pump Mode] parameter = 1:
Setting of the automatic summer switch-off of the heating operation. If the outside temperature
measured and averaged by the controller exceeds the set value by 1 K, the heating circuit is
switched off. The heating is released again if the outside temperature undercuts the set heating
limit.
E
E
Off, 10 - 40 °C
19 °C
1K
T-Outside lim night
Only if [Pump Mode] parameter = 1:
Setting the heating limit for the "Switch-off" of the heating circuit during the setback time (functioning as in [T-Outside lim day] parameter).
E
E
Off, 10 - 40 °C
10 °C
1K
Heat-Slope
Only if [HC Function] parameter = 0:
Setting of the heat slope. The heat slope reflects the dependence of the target T-HS of the
heating circuit on the outdoor temperature (see chap. 3.6.2).
E
E
0.0 - 3.0
0.5
0.1
Room Influence
Only with room control connected and assigned to the heating circuit
:
Setting that influences the deviation of the room temperature measured by EHS157034 from
the current target value (see chap. 3.4.3 and 3.4.4) has on the T-HS.
Off: Purely weather-dependent T-HS control
0: Purely weather-dependent T-HS control, but internal circulation pump continues running until the next heating cycle after a heat requirement during the setback cycle.
1-20: Causes a correction of the flow target temperature (parallel shift of the heat slope) by the
set factor. If the measured temperature lies 2 K below the target value, the flow target temperature is increased by 2x the set value.
E
E
Off, 1 - 20 K
Off
1K
T-Room Adj
Only with room control connected and assigned to the heating circuit
:
Individual adjustment of the room temperature relevant to the control unit.
If a systematic deviation of the room temperature measured by the EHS157034 to the actual
temperature in the occupied area of this room is determined, the measured value can be corrected by the set value.
E
E
-5 - 5 K
0.0 K
1K
T-Flow Day
Only if [HC Function] parameter = 1
Setting of the target T-HS for the heating circuit during the heating time in operating mode: "Automatic 1", "Automatic 2", "Heating".
E
E
20 - 90 °C
40 °C
1 °C
T-Flow Night
Only if [HC Function] parameter = 1
Setting the flow target temperature for the heating circuit during the setback time for the operating mode: "Automatic 1", "Automatic 2", "Reducing".
E
E
10 - 90 °C
10 °C
1 °C
Max T-Flow
Setting limits the T-HS (measured at tv2) with active heating support function.
The determined target T-HS of the heating circuit is limited to the maximum value set here.
If an optionally connected mixed heating circuit requests a higher temperature of the heat generator, this is taken into account. Thus, the internal circulation pump of the heat generator always runs if it is switched on. If the direct heating circuit supplies the floor heating, a
mechanical temperature limiter must be installed to prevent any overheating of the screed.
N
E
20 - 90 °C
80 °C
1 °C
Min T-Flow
The determined flow target temperature of the heating circuit is limited to the minimum value
set here.
N
E
10 - 90 °C
10 °C
1 °C
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
41
6 x Parameter settings
Parameter
HC Adaption
Description
The function can only be carried out for a
room controller connected and assigned to the
heating circuit:
Off: Deactivated
On: Activated = start of a one-time automatic heat slope adaptation.
Access
Setting range
Min / Max
Factory
setting
Increment
E
Off
On
Off
-
BE
HF
N
Prerequisites:
- Outside temperature <8 °C
- setting of the operating mode: "Automatic 1" or "Automatic 2"
- Duration of the setback period is at least 6 h
Function: At the start of the setback time, the current room temperature is set as the target value for the following 4 hours. The heat slope that is required to maintain this room temperature
is determined from the flow target temperatures by the control unit.
If the automatic heat slope adaptation is interrupted, the function pauses until the adaptation is
successfully carried out or ended the next day (setting the parameter to "Off" or changing the
current operating mode).
Hot water generation and heating optimisation is locked during the heat slope adaptation.
T-Frost Protect
Off: No frost protection of the heating circuit
Otherwise: If the outside temperature drops below the set value, the system switches to frost
protection operation (the pumps are switched on). The function is ended if the outside temperature rises above the set value +1 K.
E
E
Off,
-15 - 5 °C
0 °C
1 °C
Insulation
Setting the building insulation standard. This influences the averaged outside temperature and
the automatic adaptations of the heat slope and the heating times.
E
E
Off
low
Normal
Good
Very Good
low
-
Forced Performance
: Setting of whether the heating circuit should react to the forced performance.
Off: Deactivated
On: Heating circuit release for forced performance (acceptance obligation/acceptance block).
For superordinate system functions (e.g. in chimney sweep operation), an acceptance obligation or an acceptance block can be imposed by the heat generator on the heating circuit to cool
the heat generator or to quickly bring it back to temperature.
N
E
Off
On
On
-
Screed
Function for screed drying
Off: Deactivated
On: The flow temperature is regulated according to the parametrised screed program. The day
on which the screed function is activated is not included in the running time of the screed program. The first day starts when the day changes at 00:00 am. On the day of activation, heating
is carried out for the remaining time with the target T-HS of the program of the first day (see
chap. 3.6.7).
N
E
Off
On
Off
-
Screed Program
Setting of the sequence program of the screed heating. An individual flow temperature can be
set for each day for a maximum duration of 28 days. The end of the screed program is defined
by the 1st day with the target value setting "- - - -" (see chap. 3.6.7).
N
E
10 - 70 °C per
heating day
See
tab. 3-10
1 °C
Access
Setting range
Min / Max
Factory
setting
Increment
Tab. 6-3 Parameters in the "Configuration" rotary switch setting, "HC Configuration" level
6.2.4 "DHW Configuration" level
Parameter
Description
BE
HF
Circl-Pump DHW
Setting for the control of a circulation pump.
Off: Optional circulation pump is synchronously controlled to the active switching time program
for hot water generation.
On: Optional circulation pump is controlled according to the [Circulation Time] switching time
program.
E
E
Off
On
Off
-
Circl-Pump Interval
Setting of the interval control for an optional circulation pump.
Off: Deactivated. The circulation pump runs permanently during the release times of the assigned switching time program ([Circl-Pump DHW] parameter).
Otherwise: The circulation pump runs clocked (clock cycle ratio: pump runtime = setting value
each 15 min).
E
E
Off,
1 - 15 min
Off
1 min
Anti-Legionella day
Setting of the day for thermal disinfection of the hot water storage tank.
Off: No thermal disinfection
Monday - Sunday: Day of thermal disinfection
Mo - Su: Daily thermal disinfection
E
E
Off,
Monday
…
Sunday,
Mo - Su
Off
-
Anti-Legionella time Setting of the start time for thermal disinfection of the hot water storage tank (format hh:mm).
N
E
00:00 - 23:45
03:30
15 min
Anti-Legionella temp Setting of the hot water target temperature during thermal disinfection of the hot water storage
tank.
N
E
60 - 70 °C
65 °C
1 °C
DHW Relief
N
E
Off
On
Off
-
Operating instructions
42
: Only applicable if a storage loading pump is connected to the connection J2 of the heat
generator.
Off: Deactivated (storage loading pump is switched on with the beginning of the hot water requirement and switched off with the ending of the hot water requirement and any extended running time of the pump ([DHW Followup] parameter).)
On: Storage loading pump is only switched on if the temperature of the heat generator exceeds
the current hot water target temperature by +5 K.
The storage loading pump is switched off if the temperature of the heat generator falls below
the current hot water target temperature.
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
6 x Parameter settings
Parameter
Description
Access
BE
HF
Setting range
Min / Max
Factory
setting
Increment
Parallel DHW
: Only applicable if a storage loading pump is connected to the connection J2 of the heat
generator.
Setting of parallel pump operation during hot water generation.
Off: Hot water priority operation - All heating circuits of the system are locked during hot water
generation. Optional mix valve extension controllers close the heating circuit mix valve.
1: Part priority operation - All heating circuits of the system are locked during hot water generation as long as the temperature of the heat generator is below the set target value of the hot
water temperature plus the set value of the [T-HS DHW] parameter. If, during hot water generation, the temperature of the heat generator drops below the set target value of the hot water
loading plus the set value of the [T-HS DHW] parameter minus the set value of the [Hysteresis
DHW] parameter, the heating circuits are locked again.
2: Mix valve parallel run - During hot water generation, all mixed heating circuits of the system
are released in parallel.
3: Parallel operation - All heating circuits are released during hot water generation.
N
E
Off, 1 - 3
Off
-
T-HS DHW
Setting of the excessive increase of the target temperature specification of the heat generator
during hot water generation.
N
E
0 - 50 K
20 K
1K
Hysteresis DHW
Setting of the hysteresis for hot water generation. Hot water generation is activated if the temperature measured at the hot water sensor is less than the current hot water target temperature
minus the value set here. Hot water generation is ended if the temperature measured at the
hot water sensor is above the actual hot water target temperature.
N
E
2 - 30 K
5K
1K
Max DHW loading
time
Setting of the maximum duration of a hot water generation cycle. Then cancellation of hot water
generation if the current hot water temperature does not reach the set target value in the [TDHW Setpoint] parameter.
N
E
10 - 240 min
60 min
10 min
DHW Off Time
Setting of the blocking time after completion or cancellation of a hot water generation cycle.
The repeat request for hot water generation is operated after this blocking time has elapsed at
the earliest.
N
E
0 - 180 min
30 min
10 min
DHW Followup
: Setting of the follow-up time of the storage loading pump.
=0 min: Follow-up of 5 min, as long as no other request is made to the heat generator.
>0 min: Follow-up for the set runtime, which is not cancelled by another request to the heat
generator. A blocking function activated with the [DHW Relief] parameter also works during the
follow-up time.
Note:
This parameter is not available for the GCU compact. The follow-up time is permanently programmed to 5 min. Exception: For "Summer" operating mode, only 1 min.
N
E
0 - 30 min
0 min
10 min
Setting range
Min / Max
Factory
setting
Increment
Tab. 6-4 Parameters in the "Configuration" rotary switch setting, "DHW Configuration" level
6.2.5
"Expert Config" level (only heat generator A1)
Parameter
Description
Access
BE
HF
Max Flow Gradient
In this parameter it is possible to set how quickly the T-HS may increase in a certain period of
time before the heat generator goes into locking.
0: Off; >0: Increase in Kelvin per second
N
E
0.0 - 5.0 K/s
2.00 K/s
0.06 K/s
Max In/Out Diff
Setting of the maximum temperature difference between T-HS and T-Return.
For example:
Difference tV - tR > [Max In/Out Diff] = burner blocked
Difference tV - tR < [Max In/Out Diff] = burner not blocked
N
E
0 - 60 K
35 K
1K
Dt Reverse
Setting of the maximum difference between tR - tV within the first 5 s when the burner starts.
N
E
1 - 30 K
----
1K
Burner Starts
Sum of all starts that are stored in the firing unit of the heat generator.
N
S
-
-
1
Burner Oper Time
Overall runtime of the burner in hours, which is stored in the firing unit of the heat generator.
N
S
-
-
1h
Tab. 6-5
Parameters in the "Configuration" rotary switch setting, "Expert Config" level
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
43
6 x Parameter settings
6.2.6
"Lambda-Gx" level (only for the heat generator GCU compact)
This parameter level is not displayed if the "Standby" operating mode is active.
Parameter
Name
Access
BE
HF
Setting range
Min / Max
Factory
setting
Increment
Gas type
Changeover natural gas/liquid gas. For this, please observe the mechanical switchover of the
gas valve (see installation and maintenance instructions of the GCU compact).
N
E
Natural gas
Liquid gas
Natural gas
-
Corr qGas start
Correction value of the amount of gas for the ignition process. This value can be adjusted in
the case of starting problems.
N
E
-10 - 20 %
0
1%
100% Calibration
Off: No function
On: Manual start of the calibration. It is always necessary for a burner change or if the ionisation electrode is cleaned or replaced. The firing unit determines the new ionisation base value
by this. It takes approx. 30 - 60 s. Afterwards, the parameter value is automatically set to "Off".
N
E
Off
On
Off
-
Corr power start
Adjustment of the start power. This enables noise and start problems to be counteracted.
N
E
-16 - 14 %
0
2%
CL - Offset CES
Adjustment of the presetting of the GAS control valve. Value only works once until the next adaptation, it is then independently changed/adjusted by the controller. Adjustment can be necessary if the gas fitting is being replaced and too little gas would flow into the combustion
chamber from the control valve.
N
E
20 - 40 %
xx.x
0.2 %
BCCRe-Update
Status message, informative
N
E
Off
On
Off
-
Error Code
Active error of the firing unit (see tab. 7-2).
N
S
0
0
-
Q-SetpointRoCon
Informative - Variable process value.
N
S
-
xxx
-
Q-ActualValueRoCon
Informative - Variable process value.
N
S
-
xxx
-
T-HS
Current T-HS.
N
S
-
xxx
-
T-Return
Current T-Return.
N
S
-
xxx
-
IO-SP
Informative - Variable process value.
N
S
-
xxx
-
IO-AV
Informative - Variable process value.
N
S
-
xxx
-
ConV
Informative - Variable process value.
N
S
-
xxx
-
ConF
Informative - Variable process value.
N
S
-
xxx
-
IO-BV
Informative - Variable process value.
N
S
-
xxx
-
IO-CalMax
Informative - Variable process value.
N
S
-
xxx
-
IO-Comp
Informative - Variable process value.
N
S
-
xxx
-
IO-S
Informative - Variable process value.
N
S
-
xxx
-
FI-T
Informative - Variable process value.
N
S
-
xxx
-
IgtoCal
Number of necessary ignitions until calibration is automatically carried out.
N
S
-
xxx
-
Lerr
Last error of the firing unit (see tab. 7-2).
N
S
-
xxx
-
PLErr
Count of how often the last error has occurred.
N
S
-
xxx
-
Burner Starts
Sum of all starts that are stored in the firing unit of the heat generator.
N
S
-
-
1
Overall runtime of the burner in hours, which is stored in the firing unit of the heat generator.
N
S
-
-
1h
Setting range
Min / Max
Factory
setting
Increment
Burner Oper Time
Tab. 6-6
Parameters in the "Configuration" rotary switch setting, "Lambda-Gx" level
6.3 Rotary switch setting: DHW Reheating
Parameter
Description
Access
BE
HF
1x Hot Water
Start of a one-time hot water generation to the set target value [T-DHW Setpoint 1] without time
limit, independent of the heating programs.
E
E
Off
On
Off
-
DHW Reloadtime
Setting limits the period of time for hot water generation to the set target value [T-DHW Setpoint
1]. After the period of time has elapsed, the control unit switches back to the previously active
operating mode. Hot water generation is carried out to the then current target value.
E
E
0 - 240 min
0 min
1 min
Tab. 6-7 Parameters in the "DHW Reheating" rotary switch setting
Operating instructions
44
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
6 x Parameter settings
6.4 Rotary switch setting: Operating Mode
Parameter
Description
Access
BE
HF
Setting range
Min / Max
Factory
setting
Increment
Standby
In this operating mode all internal functions are switched off. Frost protection remains active and
a blocking protection for the pump is guaranteed.
All controllers integrated in the RoCon system via the CAN bus are primarily also switched to the
operating mode if this setting is selected.
Outputs are not always completely free of voltage.
E
E
-
Reducing
The internal heating circuit is continuously controlled (24 h per day) to the set setback temperature. Hot water generation is carried out according to [DHW Program 1].
E
E
-
Heating
The internal heating circuit is continuously controlled (24 h per day) to the set day room target
temperature (heating). Hot water generation is carried out according to [DHW Program 1].
E
E
-
Summer
The internal heating circuit is switched off. Frost protection remains active and a blocking protection for the pump is guaranteed. Hot water generation is carried out according to [DHW Program
1].
All controllers integrated in the RoCon system via the CAN bus are primarily also switched to the
operating mode if this setting is selected.
E
E
-
Automatic 1
The internal heating circuits are controlled according to the set [HC Program 1] time program with
the respective room target temperatures. Hot water generation is carried out according to [DHW
Program 1].
E
E
-
Automatic 2
The internal heating circuits are controlled according to the set [HC Program 2] time program with
the respective room target temperatures. Hot water generation is carried out according to [DHW
Program 2].
E
E
-
Tab. 6-8 Parameters in the "Operating Mode" rotary switch setting
6.5 Rotary switch setting: Set Temp Day
Parameter
Description
Access
BE
HF
Setting range
Min / Max
Factory
setting
Increment
T-Room 1 Setpoint
Target value of the room temperature in °C, which is valid for the 1st switching time cycle of the
[Automatic 1] and [Automatic 2] time programs.
E
E
5 - 40 °C
20 °C
0.5 °C
T-Room 2 Setpoint
Target value of the room temperature in °C, which is valid for the 2nd switching time cycle of the
[Automatic 1] and [Automatic 2] time programs.
E
E
5 - 40 °C
20 °C
0.5 °C
T-Room 3 Setpoint
Target value of the room temperature in °C, which is valid for the 3rd switching time cycle of the
[Automatic 1] and [Automatic 2] time programs.
E
E
5 - 40 °C
20 °C
0.5 °C
Setting range
Min / Max
Factory
setting
Increment
Tab. 6-9 Parameters in the "Set Temp Day" rotary switch setting
6.6 Rotary switch setting: Set Temp Night
Parameter
Description
Access
BE
HF
T-Reduced
Target value of the setback room temperature in °C, which is valid for the [Automatic 1] and [Automatic 2] time programs.
E
E
5 - 40 °C
10 °C
0.5 °C
T-Absence
Target value of the setback room temperature in °C, which is valid for the [Away] + [Vacation]
time programs.
E
E
5 - 40 °C
15 °C
0.5 °C
Setting range
Min / Max
Factory
setting
Increment
Tab. 6-10 Parameters in the "Set Temp Night" rotary switch setting
6.7 Rotary switch setting: DHW Set Temp
Parameter
Description
Access
BE
HF
T-DHW Setpoint 1
Target value of the hot water temperature in °C, which is valid for the 1st switching time cycle of
the [Automatic 1] and [Automatic 2] time programs.
E
E
10 - 70 °C
58 °C
1 °C
T-DHW Setpoint 2
Target value of the hot water temperature in °C, which is valid for the 2nd switching time cycle
of the [Automatic 1] and [Automatic 2] time programs.
E
E
10 - 70 °C
58 °C
1 °C
T-DHW Setpoint 3
Target value of the hot water temperature in °C, which is valid for the 3rd switching time cycle of
the [Automatic 1] and [Automatic 2] time programs.
E
E
10 - 70 °C
58 °C
1 °C
Tab. 6-11 Parameters in the "DHW Set Temp" rotary switch setting
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
45
6 x Parameter settings
6.8 Rotary switch setting: Time Program
Parameter
Description
Access
BE
HF
Setting range
Min / Max
Factory
setting
Increment
Party
With this operating mode, a one-off time can be set for the temporary heating time extension of
the internal heating circuit (format hh:mm).
E
E
00:00 - 06:00
00:00
1h
Away
With this operating mode, a one-off time can be set for temporary regulation to the parametrised
absence temperature.
E
E
00:00 - 06:00
00:00
1h
Vacation
The internal heating circuit provides continuous (24 h per day) regulation to the parametrised absence temperature ([T-Reduced] parameter).
A calendar function can be used to enter a time period of absence.
E
E
Date 1st day
Date last day
-
1 Day
Holiday
A calendar function can be used to enter a time period of presence.
E
E
Date 1st day
Date last day
-
1 Day
HC Program 1
In this menu, the 1st time program can be parametrised for the internal heating circuit. 3 switching cycles with a resolution of 15 minutes can be set. A separate entry for each weekday is possible. Format: (On) hh:mm - hh:mm (Off)
Also, the cycles from Monday to Friday, Saturday to Sunday and Monday to Sunday can be parametrised.
E
E
See
chap. 3.4.7
See tab. 3-9 15 min
HC Program 2
In this menu, the 2nd time program for the internal heating circuit can be parametrised. 3 switching cycles with a resolution of 15 minutes can be set. A separate entry for each weekday is possible. Format: (On) hh:mm - hh:mm (Off)
Also, the cycles from Monday to Friday, Saturday to Sunday and Monday to Sunday can be parametrised.
E
E
See
chap. 3.4.7
See tab. 3-9 15 min
DHW Program 1
In this menu, the 1st time program for hot water generation can be parametrised. 3 switching cycles with a resolution of 15 minutes can be set. A separate entry for each weekday is possible.
Format: (On) hh:mm - hh:mm (Off)
Also, the cycles from Monday to Friday, Saturday to Sunday and Monday to Sunday can be parametrised.
E
E
See
chap. 3.4.7
See tab. 3-9 15 min
DHW Program 2
In this menu, the 2nd time program for hot water generation can be parametrised. 3 switching
cycles with a resolution of 15 minutes can be set. A separate entry for each weekday is possible.
Format: (On) hh:mm - hh:mm (Off)
Also, the cycles from Monday to Friday, Saturday to Sunday and Monday to Sunday can be parametrised.
E
E
See
chap. 3.4.7
See tab. 3-9 15 min
Circulation Time
In this menu, a timer program for the circulation pump can be parametrised. 3 switching cycles
with a resolution of 15 minutes can be set. A separate entry for each weekday is possible. Format: (On) hh:mm - hh:mm (Off)
Also, the cycles from Monday to Friday, Saturday to Sunday and Monday to Sunday can be parametrised.
E
E
See
chap. 3.4.7
See tab. 3-9 15 min
Tab. 6-12 Parameters in the "Time Program" rotary switch setting
6.9 Rotary switch setting: Remote Param
Parameter
Description
Access
BE
HF
Setting range
Min / Max
Factory
setting
Increment
Off
On
Off
-
Bus - Scan
Off: No function
On: Control unit checks which RoCon devices are connected in the system via CAN bus lines.
Detected devices are displayed with type and data bus ID (e.g. MM#8 = mixer module with bus
ID 8).
The selection and activation of a device with the rotary button switches the function of the control
unit to the selected device (see chap. 3.4.9).
E
E
No selection
Activation switches to local device.
E
E
-
Contr BM1/BE1 #1
Activation switches to the heat generator with the bus ID X (see chap. 6.12, [BUS ID HS] parameter).
E
E
-
Mix Valve #0
Activation switches to the mixer module with the bus ID X (see chap. 6.13.1, [HC Assignment]
parameter).
E
E
-
Tab. 6-13 Parameters in the "Remote Param" rotary switch setting
Operating instructions
46
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
6 x Parameter settings
6.10 Rotary switch setting: Info
Parameter
Description
Access
BE
HF
Setting range
Min / Max
Factory
setting
Increment
Overview
Display of different current operating data (see chap. 3.4.1).
S
S
-
-
-
Water Pressure
The current water pressure is displayed in bar.
S
S
0 - 4 bar
-
0.1 bar
T-HS
The current flow temperature of the heat generator (
S
S
0 - 100 °C
-
1 °C
T-HS Setpoint
The current target temperature of the heat generator is displayed in °C.
S
S
0 - 90 °C
-
0.1 °C
T-Outside
The current outside temperature is displayed in °C.
S
S
-39 - 50 °C
T-DHW
The current temperature of the hot water storage tank is displayed in °C. If no hot water function
is activated, "- - -" is displayed.
S
S
0 - 100 °C
-
0.1 °C
T-DHW Setpoint
The current target temperature for hot water generation is displayed in °C. If no hot water function
is activated, "- - -" is displayed. Here, the current target value is always the maximum value of all
requirements relevant for this hot water circuit.
S
S
10 - 70 °C
-
0.1 °C
T-Return
The current T-Return of the heat generator is displayed in °C. If no respective sensor is connected to the heat generator, "- - -" is displayed.
S
S
0 - 100 °C
-
0.1 °C
S
S
0 - 5100 l/h
-
l/h
S
S
0 - 100 °C
-
0.1 °C
Flow Rate
tV1) is displayed in °C.
The filtered value of the current volume flow is displayed.
T-HC
The temperature of the direct heating circuit (
erwise tV1) in °C.
T-HC Setpoint
The (flow) target temperature of the direct heating circuit is displayed in °C.
S
S
0 - 90 °C
-
0.1 °C
T-Exhaust
The current flue gas temperature of the heat generator is displayed in °C.
S
S
-39 - 300 °C
-
0.1 °C
Burner
The current status of the heat generator is displayed (flame signal).
S
S
Off
On
-
-
Gas Valve 1
The current status of the oil valve of the heat generator is displayed.
Displayed value (always "Off") not relevant!
Information on the burner status, see "Overview" Info parameter
S
S
Off
On
-
-
Position 3UV
The current flow direction in the 3-way switching valve is displayed
CH: Room heating
DHW: Hot water generation
S
S
CH
DHW
-
-
Status HS pump
The current status of the internal circulation pump of the heat generator is displayed.
S
S
Off
On
-
-
Burner Starts
Sum of all starts of the burner.
The data is updated every 20 min.
S
S
-
-
1
Control Deviation
Current control deviation (target value – actual value) of the T-HS of the heat generator.
S
S
-
-
1K
Desired Output
Currently required target performance of the burner in %. A floating display is only possible for
modulating heat generators. Depending on the setting and current status of the heat generator
(set minimum performance, start phase), the current actual value of the performance can significantly deviate from the target value.
A single-stage switching burner is only requested with the target values 0 % and 100 %, a twostage switching burner only with the target values 0 %, 50 % and 100 %.
S
S
-
-
1%
HS type
The configured type of the heat generator is displayed.
S
S
-
-
-
S
S
-
-
1h
S
S
-
-
1h
Runtime Pump
Burner Oper Time
tV2 is displayed with active heating support, oth-
0.1 °C
The runtime of the internal heating circulation pump is displayed in h.
Total runtime of the burner in hours.
The data is updated every 20 min.
Mixer Position
Only 5xx: The current position of the 3-way mixing valve 3UV DHW in % is displayed.
S
S
-
-
1%
Qch
The quantity of heat of the heat generator for the heating operation is displayed in kWh.
S
S
-
-
kWh
QWP
The entire quantity of heat of the heat generator is displayed in kWh.
S
S
-
-
kWh
Qdhw
The quantity of heat of the heat generator for hot water generation is displayed in kWh.
S
S
-
-
kWh
Sw Nr B1/U1
The software and version of the operating unit are displayed.
S
S
-
-
-
Sw Nr Controller
The software number and version of the control PCB are displayed.
S
S
-
-
-
Sw Nr FA
The software number and version of the firing unit are displayed.
S
S
-
-
-
Tab. 6-14 Parameters in the "Info" rotary switch setting
Depending on the device type, the system configuration
and the version of the device software, individual information parameters listed in tab. 6-14 cannot be displayed or are displayed at another parameter level.
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
47
6 x Parameter settings
6.11 Exit key: Special Level
Parameter
Description
Access
Setting range
Min / Max
Factory
setting
Increment
E
Off
Base Load
Full Load
Off
-
BE
HF
E
Emission Measurement
Time-limited heat requirement for checking the burner settings (see chap. 3.5.1).
Manual Operation
The internal heating circuit is constantly regulated to an adjustable T-HS (see chap. 3.5.2).
E
E
20 - 80 °C
50 °C
1 °C
STL Test
Carrying out an STL test. The heat requirement is active for as long as the Exit key is pressed.
The set temperature for the limiting ([Max T-Module] parameter) is ignored during the STL test
(see chap. 3.5.3).
N
E
Off
On
Off
-
Res Emission Mon
: Display and resetting of a fault due to exceeding the maximum permitted flue gas temperature
N
E
Off
On
Off
-
FA failure
Display and resetting of the current error of the heat generator. 
If "----" is displayed, no error is pending (see chap. 7.3).
E
E
-
-
-
Protocol
Display of the error protocol. Here, the saved error messages of the heat generator and the connected data bus devices with date and error code are displayed accordingly as a menu item. By
selecting an entry by means of rotary button, all further information on the selected error message is displayed accordingly:
- Date and time of the occurrence of the error
- Error code (see chap. 7.3)
- Location information (device) of the detected error
- Bus ID of the device causing the error
E
E
-
-
-
By setting this parameter to "On" and briefly pressing on the rotary button, all entries of the error
protocol incl. the error are deleted by connected data bus devices.
N
E
Off
On
Off
-
RoCon B1/U1 Reset Resets all parameter settings to the factory setting. Required for software updates. Complete reconfiguration then necessary.
N
E
Off
On
Off
-
Parameter Reset
Resets all customer-specific parameter settings to the factory settings.
N
E
Off
On
Off
-
Timeprog Reset
Resets all permanent time programs to the factory settings (see tab. 3-9).
E
E
Off
On
Off
-
Return
This parameter is used only to exit the special level.
E
E
-
-
-
In the event of specific errors, the heat request must be taken back. This is done by activating
the [Standby] operating mode.
There are, however, conditions under which the control unit does not accept the error reset.
Delete message
Tab. 6-15 Parameters at the "Special Level" level
6.12 "Basic Configuration" parameter level
This parameter level only appears:
– during initial commissioning if "No" was selected as the
answer to the "Use Standard Config" query, or
Parameter
–
after the [System Config] parameter has been set to "Inactive"
or "Delete" in the ""Configuration"
rotary switch setting,
"Setup" level.
Description
Access
BE
Boiler Function
Setting of the system functionality of the device in the RoCon system (do not change the factory
E
(N)*
setting).
The default value of this parameter is "Single" and thus applies for a Daikin heat generator in
autonomous operating mode.
When setting the values "Slave 1" to "Slave 8", the Daikin heat generator works as a heating
module and expects an optional cascade controller for the request.
Internal hot water generation cannot be used further when operating as a heating module.
Setting range
Min / Max
Factory
setting
Increment
E
Single
(Master)*
Slave 1
…
Slave 8
Single
-
HF
Unmixed Circ Config Setting of the heating circuit ID for the direct heating circuit of the Daikin heat generator. The
heating circuit ID must be unique throughout the entire RoCon system. There must not be any
overlap with the heating circuit IDs of optional mixer circuits ([HC Assignment] parameter, see
tab. 6-17).
E
E
Off,
0 - 15
0
1
BUS ID HS
The setting must not be changed if more than 1 heat generator is integrated in the RoCon system. Several heat generators integrated in the heating installation must be regarded as a special
application. If necessary contact a Daikin service technician.
E
E
0-7
0
1
Time Master
Activation of a system-wide time master. The time master synchronises all controllers in the
RoCon system with the time and date set on the time master. For all other control units in the
system, it is no longer possible to enter the time and date. There must only be one time master
in the entire system. The parameter is not available if the time master parameter is activated on
another controller in the RoCon system.
S
E
Off
On
On
-
System Config
The system configuration of the device, consisting of sensor configuration and data bus configuration, can be deleted, activated or deactivated with this parameter. If, when first starting up,
the query for use of the standard configuration is answered with "Yes", settings suitable the basic
configuration of the heat generator are automatically activated (see chap. 6.2.1, tab. 6-1).
S
E
Inactive,
Active,
Delete
Inactive
-
Tab. 6-16 Parameters of the Basic Configuration
Operating instructions
48
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
6 x Parameter settings
6.13
Parameter levels of the EHS157068 mixer module
The parameter levels, parameter meanings, setting ranges and
connected functions are basically described in the same way as
in the previous sections.
Rotary switch setting: Operating Mode
See chap. 6.4.
Rotary switch setting: Set Temp Day
An unlimited scope of available parameters exists at the individual levels.
See chap. 6.5.
Rotary switch setting: Set Temp Night
Only the corresponding sections are referred to below. Significant differences are explained in more detail.
See chap. 6.6.
Rotary switch setting: Info
Rotary switch setting: DHW Set Temp
See chap. 6.10.
No function.
When setting the assigned control unit to "Mix Valve #0", the displayed values refer to the assigned heating circuit and the components connected to the EHS157068. (pump, mixer valve, …).
Rotary switch setting: DHW Reheating
When setting the assigned control unit to "Living Room", the [TRoom adj] parameter is available. The room target temperature
can be changed in the range -5 K to +5 K with the rotary button.
This function is not available if the control unit is used as a remote
control in terminal function.
Rotary switch setting: Time Program
No function.
See chap. 6.8.
Rotary switch setting: Configuration
See chap. 6.13.1 and 6.13.2.
Rotary switch setting: Remote Param
See chap. 6.9.
Rotary switch setting: Configuration
6.13.1
Sublevel
Parameter
, "Setup" level
Description
Access
BE
HF
Setting range
Min / Max
Factory
setting
Increment
LCD Contrast
Display contrast
E
E
1-10
4
1
LCD Brightness
Brightness of the display
E
E
0-100 %
50 %
10 %
LCD Illum Time
Lighting duration of the display
E
E
5-120 s
30 s
1s
Language
National language of the display texts on the control unit
E
E
German
English
French
Dutch
Italian
Spanish
Portuguese
German
1
Date
Current date in day/month/year format. The current day of the week is calculated automatically from the date.
E
E
Time
Time in hours/minutes format.
E
E
Keylock Function
Release of the key lock function:
Off: Key lock cannot be activated.
On: Key lock can be activated with the rotary button (see chap. 3.1).
E
E
Off
On
Off
-
Access Rights
Access code entry. Setting digit-by-digit like a combination lock (see chap. 3.6.1).
E
E
0-9
0000
1
RoCon U1 assign
Only for connected room control
:
Function of the EHS157034 room control in the data bus system:
Living Room: Room thermostat for the Daikin heat generator
Mix Valve: Mixer circuit operating unit (as mixer circuit extension or as a free-standing
mixer circuit control unit)
Solar: Not applicable
N
E
Living Room
Mix Valve
Solar
Living Room
-
Setting of the caretaker function
Off: Deactivated
On: Function active
For every EHS157034 room control whose intended use is set to "Living Room" and
that is assigned to a heat generator ([Boiler Assignment] parameter >0), the caretaker
function is activated (see chap. 4.4.5). Several room controls with active caretaker function are possible in the system.
In "Operating Mode" rotary switch setting, the operating mode setting of the heat generator is set (can deviate from the heating circuit assignment of the control unit). As a result, the functions for hot water generation can also be remotely operated from the room
controller.
N
E
Off
On
Off
-
Min Perform Pump
Lower limit for modulation of the pump power
N
E
0 - 100 %
50 %
1%
Max Perform Pump
Upper limit for modulation of the pump power
N
E
0 - 100 %
100 %
1%
In addition to the above-mentioned functions, the room controller can basically be used
as a remote control unit for the Daikin heat generator and the entire RoCon system (with
activated terminal function) (see chap. 4.4.2).
Master-RoCon
PWM Config
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
49
6 x Parameter settings
Sublevel
Parameter
Description
Access
BE
HF
Setting range
Min / Max
Factory
setting
Increment
Sensor Config
Outside Config
Configuration of the outside temperature sensor:
Off: No sensor evaluation
On: Sensor evaluation activated (if no outside temperature sensor is connected, an error
message is generated.)
N
E
Off
On
On
-
Flow Temp Config
Configuration of the mixer circuit T-HS sensor:
Off: No sensor evaluation
On: Sensor evaluation activated (if no mixer circuit T-HS sensor is connected, an error
message is generated.)
N
E
Off
On
On
-
Outside Temp Adap Individual adjustment for the measured value of the outside temperature relevant for the
control unit.
N
E
-5 - 5 K
0K
0.1 K
Terminaladress
Setting of the data bus address for system access. The set value must be unique
throughout the entire system. Confirmation of this parameter with the rotary button effects new initialisation of the control unit.
N
E
Off, 0 - 9
Off
1
Boiler Assignment
Assignment of the EHS157068 to the heat generator, corresponding setting of the [BUS
ID HS] parameter (see chap. 6.12, tab. 6-16).
N
E
0-7
0
1
HC Assignment
Assignment of the control unit to the EHS157068 mixer module.
Off: Automatic assignment if only one mixer module is in the system, otherwise the setting must coincide with the address on the address switch of the mixer module (see
chap. 4.4.2, fig. 4-1).
0-9=0-9
10 = A
11 = B
12 = C
13 = D
14 = E
15 = F
N
E
Off, 0 - 15
Off
1
Setting range
Min / Max
Factory
setting
Increment
Tab. 6-17
6.13.2
Parameters in the "Configuration" rotary switch setting, "Setup" level
Rotary switch setting: Configuration
Parameter
, "Mixer Config" level
Description
Access
BE
HF
HC Function
Various different functionalities can be assigned to the heating circuit.
0: Weather-dependent T-HS control
1: Regulation to a fixed set flow value, depending on the heating or setback mode
N
E
0-1
0
1
Pump Mode
Setting of the operating mode of the mixer circuit pump.
0: Standard mixer circuit pump switching (weather/room dependent)
1: Mixer circuit pump switching according to heating limits (optional room thermostat shutdown
works in addition).
2: Mixer circuit pump switching according to the heating program
3: Mixer circuit pump switching in continuous operation
N
E
0-3
0
1
T-Outside lim day
Only if [Pump Mode] parameter = 1
Setting of the automatic summer switch-off of the heating operation. If the outdoor temperature
measured and averaged by the controller exceeds the set heating limit by 1 K, the heating is
switched off. The heating is released again if the outdoor temperature falls below the set heat
limit.
E
E
Off, 10 - 40 °C
19 °C
0.5 K
T-Outside lim night
Only if [Pump Mode] parameter = 1
Setting of the heating limit for switching off the heating circuit during the setback time (functions
like the [T-Outside lim day] parameter).
E
E
Off, 10 - 40 °C
10 °C
0.5 K
Heat-Slope
Only if [HC Function] parameter = 0
Setting of the heat slope. The heat slope reflects the dependence of the target T-HS of the
heating circuit on the outdoor temperature (see chap. 3.6.2).
E
E
0.0 - 3.0
0.7
0.1
Room Influence
Only with room control connected and assigned to the heating circuit
:
Setting that influences the deviation of the room temperature measured by EHS157034 from
the current target value (see chap. 3.4.3 and 3.4.4) has on the T-HS.
Off: Purely weather-dependent T-HS control.
0: Purely weather-dependent T-HS control, but internal circulation pump continues running until the next heating cycle after a heat requirement during the setback cycle.
1-20: Causes a correction of the flow target temperature (parallel shift of the heat slope) by the
set factor. If the measured temperature lies 2 K below the target value, the flow target temperature is increased by 2x the set value.
E
E
Off, 1 - 20 K
Off
1K
T-Room Adj
Only with room control connected and assigned to the heating circuit
:
Individual adjustment of the room temperature relevant to the control unit.
If a systematic deviation of the room temperature measured by the EHS157034 to the actual
temperature in the occupied area of this room is determined, the measured value can be corrected by the set value.
E
E
-5 - 5 K
0.0 K
1K
T-Flow Day
Only if [HC Function] parameter = 1
Setting of the target T-HS for the heating circuit during the heating time in operating mode: [Automatic 1], [Automatic 2], [Heating].
E
E
20 - 90 °C
40 °C
1 °C
T-Flow Night
Only if [HC Function] parameter = 1
Setting of the flow target temperature for the heating circuit during the setback time for operating mode: [Automatic 1], [Automatic 2], [Reducing].
E
E
10 - 90 °C
10 °C
1 °C
Max T-Flow
The determined target T-HS of the heating circuit is limited to the maximum value set here.
N
E
20 - 70 °C
50 °C
1 °C
Operating instructions
50
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
6 x Parameter settings
Parameter
Description
HC Adaption
The function can only be carried out for a
room controller connected and assigned to the
heating circuit:
Off: Deactivated
On: Activated = start of a one-time automatic heat slope adaptation.
Access
Setting range
Min / Max
Factory
setting
Increment
E
Off
On
Off
-
BE
HF
N
Prerequisites:
- Outside temperature <8 °C
- setting of the operating mode: "Automatic 1" or "Automatic 2"
- Duration of the setback period is at least 6 h
Function: At the start of the setback time, the current room temperature is set as the target value for the following 4 hours. The heat slope that is required to maintain this room temperature
is determined from the flow target temperatures by the control unit.
If the automatic heat slope adaptation is interrupted, the function pauses until the adaptation is
successfully carried out or ended the next day (setting the parameter to "Off" or changing the
current operating mode).
Heating optimisation is locked during automatic heat slope adaptation.
T-Frost Protect
Off: No frost protection of the heating circuit
Otherwise: If the outside temperature drops below the set value, the system switches to frost
protection operation (the pumps are switched on). The function is ended if the outside temperature rises above the set value +1 K.
E
E
Off,
-5 to + 5 °C
0 °C
1 °C
Insulation
Setting the building insulation standard. This influences the averaged outside temperature and
the automatic adaptations of the heat slope and the heating times.
E
E
Off
low
Normal
Good
Very Good
Normal
-
Forced Performance Setting of whether the heating circuit should react to the forced performance.
Off: Deactivated
On: Heating circuit release during forced performance (acceptance obligation/acceptance
block, see chap. 6.2.3, tab. 6-3).
N
E
Off
On
On
-
Start T-Out Cooling
Only applicable if the assigned heat generator has a cooling function.
Setting of from which outside temperature the cooling operation starts. The control logic for the
mixer motor is reset to heating operation if the outside temperature falls below the set value 1 K.
E
E
20 - 45 °C
24 °C
1 °C
Max T-Out Cooling
Only applicable if the assigned heat generator has a cooling function.
Setting of from which outside temperature the lowest cooling target T-HS ([T-Flow Cooling
max] parameter) or the highest target value of the room temperature ([T-Room max Cooling]
parameter) is specified.
E
E
20 - 45 °C
35 °C
1 °C
T-Flow Cooling start Only applicable if the assigned heat generator has a cooling function.
Setting of the cooling target T-HS during the start of cooling operation (outside temperature =
[Start T-Out Cooling] parameter).
E
E
5 - 25 °C
18 °C
1 °C
T-Flow Cooling max Only applicable if the assigned heat generator has a cooling function.
Setting of the minimum cooling target T-HS. This is held constant as of the outside temperature
([Max T-Out Cooling] parameter).
E
E
5 - 25 °C
18 °C
1 °C
Min T-Flow Cooling
Only applicable if the assigned heat generator has a cooling function.
Setting of the absolute lower limit of the cooling target T-HS. Limitation works if a lower cooling
target T-HS is determined from another parameter setting.
E
E
5 - 25 °C
8 °C
1 °C
T-Flow Cooling
Only applicable if the assigned heat generator has a cooling function.
Only if [HC Function] parameter = 1
Setting of the target T-HS for active cooling operation.
E
E
8 - 30 °C
18 °C
1 °C
Cooling Setpoint adj Only applicable if the assigned heat generator has a cooling function.
Parallel shift of the cooling characteristic curve by the set value.
N
E
-5.0 to +5.0 kW
0.0 K
1K
Relay Test
See chap. 6.2.2, tab. 6-2.
E
E
Screed
Function for screed drying
Off: Deactivated
On: The flow temperature is regulated according to the parametrised screed program. The day
on which the screed function is activated is not included in the running time of the screed program. The first day starts when the day changes at 00:00 am. On the day of activation, heating
is carried out for the remaining time with the target T-HS of the program of the first day (see
chap. 3.6.7).
N
E
Off
On
Off
-
Screed Program
Setting of the sequence program of the screed heating. An individual flow temperature can be
set for each day for a maximum duration of 28 days. The end of the screed program is defined
by the 1st day with the target value setting "- - - -" (see chap. 3.6.7).
N
E
10 - 70 °C per
heating day
See
tab. 3-10
1 °C
Tab. 6-18
-
Parameters in the "Configuration" rotary switch setting, "Mixer Config" level
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
51
7 x Errors and faults
7
Errors and faults
7.1.2 Reading the error protocol
The error protocol can be read at the "Special Level" (see
fig. 7-2).
CAUTION!
Electrostatic charges can lead to voltage arcing
that can destroy the electronic components.
Ensure potential equalisation prior to touching
the switching panel PCB (e.g. by touching the
switching panel holder).
Here, the latest (most recent) error message received is given top
priority. All other previous error messages are then pushed down
by one place by each new entry. The 16th error message is deleted if a new error message arrives.
7.1 Detecting errors and rectifying faults
The electronic control unit recognises and saves errors. They are
displayed by an error message on the display:
– Backlit in red (see also chap. 3.2.1)
– Error code (see tab. 7-3).
An integrated error protocol saves up to 15 of the last error messages that occurred.
Read Protocol
Special Level
Protocol
Emission Measurement
Manual Operation
Depending on the operating mode, the error messages are also
forwarded to connected room controllers or room thermostats.
7.1.1 Current error display
Special Level
E 12
Inside Unit::Boiler
Address::0
1
2
3
2
3
FA failure
Inside Unit:: Boiler
Protocol
Delete message
Address:: 0
Error code (see chap. 7.3)
Location data (device) of the detected error
Data bus address of the device that caused the error
Fig. 7-1
Display of a current error message
Operating instructions
52
1
Fig. 7-2
Reading the error protocol
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
7 x Errors and faults
7.1.3 Deleting errors, unlocking the firing unit
7.1.4 Rectifying faults
The cause of the most recent error is saved in the
device and can be reconstructed even after a power
failure when the device is restarted.
Locking errors detected by the firing unit can only be unlocked manually directly on the boiler.
Requirements: The cause of the fault has been rectified, the
burner is connected to the electrical system.
1. Switch on the Daikin heat generator.
2. Press the Exit key (fig. 7-3) for at least 5 s.
 The "Special Level" menu is displayed.
3. Use the rotary button to select the "FA failure" level.
 Error code and "Reset?" request is displayed.
WARNING!
Risk of burns from a very hot boiler body in the
event of an STL fault.
● Do no let any metallic parts come into contact
with the boiler.
● Let the boiler cool down.
● Wear protective gloves.
–
4. Use the rotary button to select "Yes".
5. Confirm the selection with a brief push of the rotary button.
 The error is reset.
6. Cancellation and jump back by pushing the Exit button again.
FA failure
Reset?
Yes
Special Level
FA failure
Reset?
Emission Measurement
Manual Operation
No
Yes
No
–
Contactor triggered:
Nothing shown on the control unit display.
● Search for and rectify causes.
● Start the system again.
 If the cause has been rectified, the system continues to
work normally.
Contactor not triggered:
a) No error codes are shown, but the system is not working
properly.
● Search for and rectify causes.
 Once the cause has been eliminated, the system continues to work normally.
b) Error codes are displayed as long as fault conditions are
present.
● Search for and rectify faults (see chap. 7.3).
● Unlock the system (see chap. 7.1.3).
 Once the cause has been eliminated, the system continues to work normally.
To ensure that the error is not caused by incorrect settings, reset all parameters to the factory settings before
any possible replacement of components (see
chap. 3.6.6).
If it is not possible to determine the cause of the fault, please
consult a Daikin service technician.
Special Level
Special Level
STL Test
STL Test
FA failure
FA failure
Protocol
Protocol
Please keep the essential device data ready for this (procedure,
fig. 7-4):
– Type and manufacturer number of the Daikin heat generator (see heat generator type plate).
– Software versions (see fig. 7-4) of:
a: RoCon B1 control unit [Sw Nr B1/U1]
b: RoCon BE1 control panel [Sw Nr Controller]
c: Firing unit [Sw Nr FA]
– For optional RoCon system components:
EHS157034 [Sw Nr B1/U1]
EHS157068 [Sw Nr mixing valve]
Special Level
Timeprog Reset
Return
Fig. 7-3
Deleting errors
If an error or a fault has been rectified and the device is
working normally again, an "E0" entry is saved in the
error protocol with a time stamp.
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
53
7 x Errors and faults
7.2 Emergency operation
For faults or incorrect settings of the electronic control unit,
emergency heating operation (manual operation) can be
maintained.
Please observe the supplementary notes for this in the installation manual of the heat generator.
1. Push the Exit button for at least 5 s.
 The "Special Level" menu is displayed.
Sw Nr B1/U1
Info
2. Use the rotary button to select the "Manual Operation" level.
 Temperature scale, target and target T-HS are displayed.
3. Use the rotary button to set the target T-HS.
 The Daikin heat generator works manually at the target THS.
Overview
Water Pressure
T-HS
4. Cancellation and jump back by pushing the Exit button again.
Info
Sw Nr B1/U1
Sw Nr Controller
Sw Nr FA
Sw Nr Controller
Sw Nr FA
Info
Sw Nr B1/U1
Sw Nr mixing valve
Fig. 7-4
Software information of the control unit components
Operating instructions
54
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
7 x Errors and faults
7.3 Error codes
Code
Component/Designation
Error
E1
Safety temperature limitation: T-HS >105 °C, T-Return >95 °C
E4
No flame detection during the burner start.
E5
More than 5 flame interruptions during a continuous burner requirement.
E11
Flame detection prior to burner start.
E12
tV or tR temperature sensor defective (cable break, short circuit).
E15
Oil preheater does not switch within 5 min.
E34
BCC data conflict
E35
Required BCC not detected.
E36
BCC data conflict
E37
BCC firmware does not match the firmware of the firing unit.
E38
Incorrect BCC number.
E39
BCC system error
E65
During calibration, deviation from previous value too high (unclean supply air, electrode replacement, electrode defective).
E99
Internal error of the firing unit.
E129
T-HS exceeds limiter temperature (excessive temperature, no heat dissipation)
E130
T-Return exceeds limiter temperature (excessive temperature, no heat dissipation)
E132
5x no flame formation at the end of the safety time (no gas, valves do not open, no ignition
sparks)
E138
5x flame failure at the end of the safety time (ionisation electrode defective or dirty)
E148
2x gas valve test negative. A flame is still detected 15 s after the burner shut-down (gas valve
jams).
E152
Firing unit
Locking error
Speed not reached during pre- and post-ventilation (burner blower defective, power supply to
blower, electronics error in blower, cable break).
E154
Blower stationary position not reached (burner blower defective, electronics error in burner
blower).
E158
EEPROM error (manufacturer’s parameter).
E159
EEPROM error (safety parameter).
E189
Control deviation of the ionisation current too high (from 2nd error) (faulty burner earthing or
firing unit supply current, gas flow pressure too low, ionisation electrode bent or oxidised, ionisation track faulty, safety gas control block defective).
E190
–
–
Impermissible gas valve initialisation within 10 s (from 2nd error) or
blower falls below 80 % of the minimum speed within 10 s (from 2nd error).
(Burner blower defective, incorrect gas type set, missing/wrong gas nozzle, safety gas control block defective, gas flow pressure too low)
E191
Internal electronic error - from 2nd error (switch device on/off).
E192
A value fell below the minimum limit values during calibration (flue gas recirculation, electrodes oxidised, ionisation track faulty, poor earthing, transition resistances).
E194
Interruption during calibration (from 2nd error) (no heat dissipation, minimum calibration time
not met).
E195
Impermissible internal basic value (electronic error).
E202
A value exceeded the maximum limit values during calibration (unclean supply air, basic
value too high).
E215
EEPROM error (electronics error).
E226
Error found in the flame amplifier evaluation during the idle state check (electronics error,
short circuit of ionisation electrode or cable).
E227
Internal error of the firing unit.
Tab. 7-1 Error code of locking faults (can be detected by the firing unit)
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
55
7 x Errors and faults
Code
Component/Designation
Error
E1
T-HS exceeds limiter temperature (excessive temperature, no heat dissipation).
E2
T-Return exceeds limiter temperature (excessive temperature, no heat dissipation).
E6
T-HS (tV) is higher than the set maximum boiler temperature ([Max T-HS] parameter + 5 K).
E12
T-HS or T-Return sensor: Measured value outside measuring range, temperature sensor
defective.
E17
Spread (tV - tR) too large.
E32
E43
E44
E45
E66
Firing unit
Undervoltage in the 230 V mains voltage or 18 V internal DC voltage (electronics error, switch
device on/off).
T-Return (tR1) is higher than T-HS (tV1) + 12 K for longer than 5 s.
Temporary fault, burner
T-HS increase too rapid.
shut-down, automatic release when error condition Spread (tV1 - tR1) too large.
no longer active.
Interruption during calibration (no heat dissipation, minimum calibration time not met).
E90
Communication interrupted between firing unit and control unit switching panel PCB (check
cable and plug connections, total reset, replace control unit switching panel PCB, replace firing unit).
E96
5x reset within 15 min. Another reset is not possible until after a further 15 min.
E98
Error found in the flame amplifier evaluation during the idle state check (electronics error,
short circuit of ionisation electrode or cable).
E99
Internal error of the firing unit.
E4
1-4x no flame formation at the end of the safety time (no gas, valves do not open, no ignition
sparks)
E5
Flame failure in flame stabilisation (ionisation electrode defective or dirty).
E10
Flame failure at the end of the safety time (ionisation electrode defective or dirty).
E10
5x reset within 15 min. Repeat reset only possible after 15 min.
E19
T-HS increase too rapid.
E24
Value exceeds/falls below min. and max. limits during flame stabilisation or control operation
(blower defective, power supply to blower, electronics error in blower, cable break).
E48
No communication with the firing unit for more than 2 min.
E50
BCC activation or flame failure in regular operation (no gas, wind effect, safety gas control
block supply).
Firing unit
E61
Temporary fault, device is
attempting to restart
E62
Control deviation of the ionisation current too high (1st error) (faulty burner earthing or firing
unit voltage supply, gas flow pressure too low, ionisation electrode bent or oxidised, ionisation
track faulty, safety gas control block defective)
–
–
Impermissible gas fitting initialisation during 10 s (1st error) or
blower falls below 80 % of the minimum speed within 10 s (one-off error).
(Burner blower defective, incorrect gas type set, missing/wrong gas nozzle, safety gas control block defective, gas flow pressure too low)
E63
Internal electronics error - 1st error (switch device on/off).
E66
Interruption during calibration (1st error) (no heat dissipation, minimum calibration time not
met).
E68
Impermissible GPV offset value (safety gas control block defective).
E69
During adjustment, no stable state reached in partial load within the tolerance period (wind
effect, speed fluctuations, blower).
Tab. 7-2 Error code of non locking faults (can be detected by the firing unit)
Operating instructions
56
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
7 x Errors and faults
Code
Component/Designation
Error
Possible error rectification
E72
Internal mixer sensor tV2
E75
External temperature sensor
E76
Storage tank temperature
sensor
E81
EEPROM
E88
Control unit switching panel Internal error.
PCB
● Total reset
● Replace control unit switching panel
PCB.
E91
Connected CAN modules
CAN module bus ID duplicated.
● Configure bus addresses correctly.
Measured value outside measuring range,
sensor/temperature sensor defective.
● Check cable, terminal and plug connections.
● Replace sensor/temperature sensor.
E100 (1
Flue gas temperature sensor
Measured value outside measuring range,
temperature sensor defective.
(1
locking error if the flue gas temperature sensor is obligatory for this heat generator type (e.g. Daikin A1).
Burner release only takes place if the fault has been
manually unlocked.
● Check cable, terminal and plug connections.
● Replace temperature sensor.
E129
Temperature sensor in the
Measured value outside measuring range,
flow sensor
sensor/temperature sensor defective.
Pressure sensor
● Check cable, terminal and plug connections.
● Replace sensor/temperature sensor.
E198
Flow sensor
Volume flow too low.
● Check heating circulation
pump/filter/heating network.
Communication, firing unit
Communication interrupted between firing
unit and control unit switching panel PCB.
● Check cable and plug connections.
● Total reset
● Replace control unit switching panel
PCB.
● Replace the firing unit.
Flow sensor
Warning message: Measured value less than ● Check parameter settings (see tab. 6-2).
recommended minimum flow.
● Check pipes and valves for blockages.
● Check integrated heating circulation
Measured value under permitted minimum
pump.
value. Flow sensor/integrated heating circulation pump defective.
Flue gas temperature
Warning message: The flue gas temperature ● Clean the boiler.
has exceeded the limit temperature.
● Check flue gas temperature sensor.
Flue temperature has exceeded the permissible absolute maximum value.
E128
E200
W8001
E8002
W8003
E8004
Measured value under permissible minimum
value.
E8005
W8006
Water pressure
● Top up heating water.
● Leak test.
Warning message: Maximum permissible
pressure drop exceeded.
Warning message: Measured value exceeds ● Check diaphragm expansion vessel.
● Drain heating water.
permissible maximum value.
W8007
Tab. 7-3 Error codes (can be detected by the switching panel PCB)
Observe maximum tightening torque of 10 Nm for all
temperature sensors.
For further information on possible errors and faults, see applicable documents.
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
57
8 x Glossary
8
Glossary
Operating mode
Request by the user or the control unit for the function of the heat generator (e.g. room heating, hot
water generation, standby, etc.)
Heating characteristic curve Mathematical relationship between the external temperature and the target T-HS (synonym = heat
slope) in order to achieve the desired room temperature at all outside temperatures.
Anti-legionella system
Periodic heating of the storage water to >60 °C for the preventative elimination of pathogenic bacteria
(so-called legionella) in the hot water circuit.
Modulation
Automatic and stepless adjustment of the heating performance/pump performance to the respective
heating requirement, without different heating/pump steps or cycles having to be switched.
Nominal output
Maximum heating performance, which the heat generator provides under test conditions for certain operating temperatures.
Parameter
A value that influences the execution of programs or processes or defines specific states.
Control unit
Device electronics that are used to control the processes for the heat generation and heat distribution
of the heating system. The control unit consists of a number of electronic components. The most important component for the operator is the control unit in the front area of the heat generator, which includes program selection keys, rotary switches and display.
Return flow
Part of the hydraulic circuit that directs the cooled water from the heating surfaces in the rooms back
to the heat generator via the piping system.
Switching time program
Program for setting the times on the control unit in order to determine the regular heating, reducing and
hot water cycles.
Flow
Part of the hydraulic circuit that diverts the heated water from the heat generator to the heating surfaces.
Domestic hot water circuit
Is the water circuit in which cold water is heated and diverted to the hot water tap.
Domestic hot water generation
Operating status of the heat generator in which heat with elevated temperatures is generated and fed
to the hot water circuit, e.g. loading of the hot water storage tank.
Heat exchanger
A component that transfers thermal energy from one circuit to another. The two circuits are separated
from each other hydraulically by a wall in the heat exchanger.
Water shortage/Overheating Safety device which automatically switches off the boiler in the event of a water shortage to prevent
protection
overheating.
Weather-dependent T-HS
control
A suitable T-HS is determined from the measured value for the external temperature and a defined
heat slope; this temperature is used as the target value for temperature control in the heating unit.
Circulation pump
Is an additional electrical circulation pump that permanently circulates the hot water in the hot water
lines, thus providing it immediately at every tap. This circulation is especially useful in extensive
pipeline networks. In systems without a circulation line, first the water cooled in the sampling line escapes during the sampling process until the sampling line has been sufficiently heated by the inflowing
hot water.
Operating instructions
58
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
9 x Notes
9
Notes
9.1 User-specific settings
9.1.1 Switching time program
The factory settings of the switching time programs are stated in
chap. 3.4.7, tab. 3-9.
Switching cycle 1
● Enter your switching time settings in the table below.
Switching cycle 2
Switching cycle 3
Temperature
setting
[T-Room 1 Setpoint]: ____ °C
[T-Room 2 Setpoint]: ____ °C
[T-Room 3 Setpoint]: ____ °C
Time period
On
On
On
Off
Off
Off
Monday
HC Program 1
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Monday
HC Program 2
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Tab. 9-1 Individual settings in the heating timer programs
Switching cycle 1
Temperature
setting
Time period
[T-DHW Setpoint 1]: ____ °C
On
Off
Switching cycle 2
[T-DHW Setpoint 2]: ____ °C
On
Off
Switching cycle 3
[T-DHW Setpoint 3]: ____ °C
On
Off
DHW Program 1
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
DHW Program 2
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Tab. 9-2 Individual settings in the hot water timer programs
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
59
9 x Notes
Switching cycle 1
Time period
On
Switching cycle 2
Off
On
Off
Switching cycle 3
On
Off
Circulation Time
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Tab. 9-3 Individual settings of the circulation switching time program
9.1.2 Parameter
● Enter the parameter changes you made in the table below
and in the operating manual of the heat generator.
Rotary switch
setting
Parameter
level
Parameter
Old value
New value
Date
Comments
Tab. 9-4 Individual parameter modifications
9.1.3 Data bus addresses
RoCon device
Data bus address
Comments
Tab. 9-5 Data bus addresses in the RoCon system
Operating instructions
60
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
9 x Notes
9.2
Notes
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
61
9 x Notes
Operating instructions
62
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
10 x List of keywords
10 List of keywords
A
Address switch . . . . . . . . . . . . . 31, 32
Air Purge . . . . . . . . . . . . . . . . . . 23, 39
Anti-legionella system . . . . . . . . 24, 58
B
Basic functions
Displaying system information . . . 10
Setting the language, date and time
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Switching the system on and off . . 12
Water pressure display . . . . . . . . . 11
Burner blocking contact . . . . . . . . . 13
Burner faults . . . . . . . . . . . . . . . . . . 54
Bus - Scan . . . . . . . . . . . . . . . . . . . 17
C
Caretaker function . . . . . . . . . . . . . 49
Circulation pump . . . . . . . . . . . . 15, 27
Cleaning . . . . . . . . . . . . . . . . . . . . . . 8
D
Data bus . . . . . . . . . . . . . . . 29, 38, 48
Device ID . . . . . . . . . . . . . . . . . 30, 31
Display . . . . . . . . . . . . . . . . . . . . . . . 8
E
Emergency operation . . . . . . . . . . . 54
Error . . . . . . . . . . . . . . . . . . . . . . . . 19
Error message . . . . . . . . . . . . . . . . 52
Explanation of symbols . . . . . . . . . . . 5
F
Factory setting . . . . . . . . . . . . . 24, 38
Frost protection function . . . . . 7, 8, 27
G
Glossary . . . . . . . . . . . . . . . . . . . . . 58
H
Heat generator ID . . . . . . . . . . . . . .
Heat slope . . . . . . . . . . . . . . . . . . . .
Heating circuit ID . 29, 30, 32, 33,
Heating cycle . . . . . . . . . . . . . . . . .
Heating support function . . . . . . . . .
29
22
48
15
27
K
Keylock . . . . . . . . . . . . . . . . . . . . . . 10
L
Language setting . . . . . . . . . . . . . . 17
M
Manual operation . . . . . . . . . . . . . . 19
Master-RoCon function . . . . . . . 30, 38
Mixer module . . . . . . . . . . . 23, 31, 33
O
P
Parameter . . . . . . . . . . . . . . . . . . . . 58
Pressure monitoring function . . . . . 40
R
Reference travel . . . . . . . . . . . . . . . 21
Relevant documents . . . . . . . . . . . . . 5
Remote control via Internet . . . . . . . 27
RESET . . . . . . . . . . . . . . . . . . . . . . 24
Room station . . . . . . . . . . . . . . . . . . 32
Rotary switch setting . . . . . . . . . . . . 10
S
Safety shut-down . . . . . . . . . . . . . . . 7
Screed program
Function heating . . . . . . . . . . . . . . 25
Screed curing heating . . . . . . . . . . 25
Sensor test . . . . . . . . . . . . . . . . . . . 27
Setting the date . . . . . . . . . . . . . . . . 17
Setting the time . . . . . . . . . . . . . . . . 17
SmartStart function . . . . . . . . . . . . . 28
Software information . . . . . . . . . 10, 54
Special function
Switching contacts . . . . . . . . . . . . 28
Special level . . . . . . . . . . . . . . . . . . 19
Switching time program . . . . . . . . . 14
Permanent programs . . . . . . . . . . 14
Personal settings . . . . . . . . . . . . . 59
Setting . . . . . . . . . . . . . . . . . . . . . . 14
Temporary programs . . . . . . . . . . 16
System temperatures . . . . . . . . . . . 10
T
Technician code . . . . . . . . . . . . 21,
Temperature setting
Daytime room temperature . . . . . .
Domestic hot water mode . . . . . . .
Economy mode . . . . . . . . . . . . . . .
Terminal address . . . . . . . . . . . . . .
Terminal function . . . . . . . . . . . . . .
Terminal ID . . . . . . . . . 29, 30, 32,
Terminal operation . . . . . . . . . . . . .
Time programs
Away . . . . . . . . . . . . . . . . . . . . . . .
Holiday . . . . . . . . . . . . . . . . . . . . .
Party . . . . . . . . . . . . . . . . . . . . . . .
Vacation . . . . . . . . . . . . . . . . . . . .
38
14
14
14
32
17
39
18
16
16
16
16
U
Use as intended . . . . . . . . . . . . . . . . 6
W
Water pressure . . . . . . . . . . . . . . . . 11
Z
Zone control . . . . . . . . . . . . . . . . . . 23
Operating elements . . . . . . . . . . . . . 9
Exit key . . . . . . . . . . . . . . . . . . . . . . 9
Rotary button . . . . . . . . . . . . . . . . . 9
Rotary switch . . . . . . . . . . . . . . . . . 9
Operating modes
Automatic 1 . . . . . . . . . . . . . . . . . . 13
Automatic 2 . . . . . . . . . . . . . . . . . . 13
Heating . . . . . . . . . . . . . . . . . . . . . 13
Reducing . . . . . . . . . . . . . . . . . . . 13
Standby . . . . . . . . . . . . . . . . . . . . 12
Summer . . . . . . . . . . . . . . . . . . . . 13
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
63
Copyright © Daikin
008.1543999_00 – EN
03/2017
Was this manual useful for you? yes no
Thank you for your participation!