drain water tempering kit

DRAIN WATER TEMPERING KIT
CREW
• This kit should be installed only by qualified service personnel to reduce the risk of electric shock,
serious injury, or fire. A plumbing permit and the services of a licensed plumber and electrician
might be required in some areas.
• Turn off the power supply and place the dishwasher disconnect (if applicable) in the off position.
Lockout/tag-out to prevent the power supply from being turned back on accidentally.
• Failure to install this kit within the guidelines might adversely affect safety, performance,
component life, and warranty coverage.
• Do NOT pull power for the Drain Water Tempering Assembly from the machine! 120 V facility
power only!
Tools Required
•
•
•
•
•
•
•
Pipe Wrench
Adjustable Wrench
5/16” Nut Driver
3/8” Nut Driver or Wrench
Phillips Screwdriver
Pipe Thread Sealant Tape or Pipe Dope
Needle-nose Pliers
Instructions
1. Connect Drain Water Tempering Assembly to the machine drain via 1.5” NPT street elbow
(04730-206-32-00).
2. Orient assembly as shown below:
05700-004-54-73-A
1 of 2
DRAIN WATER TEMPERING KIT
CREW
3. Connect user-supplied 115 V cord (from facility power) into solenoid box as shown below:
DRAIN
WATER
TEMPERING
SYSTEM
DRAIN
QUENCH
SYSTEM
Power cannot
be taken from
the machine!
4. Connect cold water to inlet side of solenoid valve.
5. Secure all electrical (ensure connection is to 120 V facility power) and plumbing connections.
6. Restore water and power to the machine and verify drain quench performance.
IF THERE ARE ANY ISSUES AFTER INSTALLATION,
PLEASE CONTACT TECHNICAL SERVICE AT 1-888-800-5672.
05700-004-54-73-A
2 of 2