click seal flexible hose connector instructions

CLICK SEAL FLEXIBLE HOSE
CONNECTOR INSTRUCTIONS
Before starting work:
1. Turn off water supply to point of installation.
2. Drain system where necessary.
3. If required, clean all existing threads on
mating parts.
4. Some work is subject to regulations - if in
doubt consult your water authority or a
competent plumber.
5. When installing the Fluidmaster Click Seal®
connector, please ensure the product is not:
Bent at sharp angles; squashed; kinked;
stretched; twisted or split.
CLICK SEAL FITTING
Installation instructions:
1. Place Click Seal nut onto end of tap or toilet
valve thread.
2. Turn Click Seal nut clockwise and
HAND-TIGHTEN until nut clicks.
"The click lets you know it's sealed."®
15mm COMPRESSION FITTING
Installation instructions:
15mm COPPER TUBE
NUT
OLIVE
FLEXIBLE HOSE
1. Prepare end of copper tube ensuring clean,
smooth and bur-free fitting available.
2. Connect the compression joint by sliding the
nut then the olive over the copper tube.
3. Position the hose and hand tighten.
4. Tighten compression nut first by hand, then
using a suitable wrench tighten firmly.
DO NOT OVER TIGHTEN.
5. Slowly turn on water supply and check there
are no leaks. Tighten nut further if necessary.
6. If in doubt, contact a competent plumber.