high efficiency condensing boiler with premix boiler

540kW -
Condensing Boiler with Premix Burner
HIGH EFFICIENCY CONDENSING
BOILER WITH PREMIX BOILER
%108 efficiency
Small volume
Environmental friendly
16 pcs. cascade connection
opportunity
1/7 modulation ratio
Low flue gas temperature
(35°C - 65°C)
Possibility of control over
the internet with web server
Flue gas temperature and
return water temperature
difference 3°C - 5°C
1,100 kW within single boiler - 17,600 kW within single panel
The only one and first floor standing condensing boiler with aluminium and premix burner in all over Europe
540kW -
Condensing Boiler with Premix Burner
THE NEW PRODUCT OF CASTING AND CONDENSING
TECHNOLOGY ALUBOX FLOOR STANDING CONDENSING BOILER
ADVANTAGES OF ALUBOX FLOOR STANDING CONDENSING BOILERS
Heat exchanger with aluminium-silicon alloy
and flexible cast iron bod .
Homogeneous heat distribution with metal fiber
coated stainless steel burner.
Due to 3°C - 5°C of flue gas and boiler return
water temperature, it provides high energy saving.
It works with high efficiency even at high capacities.
%108 at 50°C/30°C, %97,5 at 80°C/60°C.
High efficiency with premix technolog . Ideal
combustion can be provided by using compatible
components (gas valve, venturi and fan) with
the help of optimum gas and air mixing.
Alubox boilers can work compatible with building
automation systems. Alubox boilers also provides
to control with room thermostat, outdoor temperature
control, zone control, cascade connection,
hot water tank, swimming pool heating, solar and
internet control with web server connection.
Environmental friendly thanks to condensing
technology. Alubox boilers provides class 5 NOx
value which is excellent for nature. (2009/142 EEC).
Alubox 208 and 290kW model deserved
class
(according to 92/42 EEC) thanks to its high efficienc .
Thanks to 1:7 modulation ratio, Alubox boilers allows
to work from 162,7kW to 1107,6 kW depends on
seasonal changes.
Alubox boilers can be cascaded up to 16 boiler
(1 master boiler and 15 slave boilers)
Compact design; this system can find a place in your
area thanks to small dimensions even its high power.
540kW -
Condensing Boiler with Premix Burner
EXCELLENT THERMAL CONDUCTIVITY AND %108 EFFICIENCY WITH INNOVATIVE
CASTING TECHNOLOGY AND SPECIAL FLEXIBLE ALUMINIUM ALLOY
Protec e oxide coaa ng on aluminium body ovides excellent
corrosion durability and long life.
Heat transfer area is increased by pins which is located on
interior surface of aluminium body. Pins has developed with
perfect heat transfer technology and increases heat transfer
coefficient than creates resistance and slow down high
temperature flue gas when the gasses pass through them.
This heat is transferred to the water op mall.
Thanks to this applied technology to aluminium sec ons,
180° C boiler temperature is transferred to water then
flue gas spread with 56° C to atmosphere. With the help
of this technology high efficiency can be achieved and
nature is saved with low emissions.
Superior safety systems;
High water pressure safety; the boiler safety is provided against in excess of 6 bar water pressure.
The automa c air ent; blows out the air which is jammed in the boiler in water circuit. This provides your system working
properly and protect against corrosion.
Ionisa on electode; checks the if combuss on on burner or not, if th e is no flame on the burner, automaomally close
the gas inlet to make system safety.
Low water pressure safety; checks the boiler water pressure con nuousl. If the pressure lower than 0,8 bar,
closes the system.
Hot water temperature safety; if boiler water temperature exceeds 95°C, sensors will shut down system to protect itself.
Overhea ng po ec on; this sens s will close the system when boiler water temperature exceeds 105°C as and in case
of failure with NTC sensors.
Flue gas temperature safety; this detects flue gas temperature with flue gas sensor. If flue temperature exceeds the limit,
stops the system.
Frost protec on; boiler orks automaatally to rise up temperature to 15°C when boiler water temperature down to 4°C so
avoid frost risk of boiler. Boiler electrical supply must be on and boiler must be in stand-by state for using this func on.
Pump protec on; this potects the boiler against pump jamming and oxidaa on. Boiler is orked certain day of the week
by control panel, if the boiler is not run long term.
Legionella protec on; if domes c hot ater in hot water tank stays lower than 60°C long term without use, this leads to
form legionella bacteria. Boiler is worked certain day to rise up use water temperature 65°C for avoiding these bacterias.
High and low voltage protec on; boiler is potected against voltage fluctuaua on.
Domes c hot ater frost pro ec on; if o mode chosen from control panel, the boiler water temperature keep fixed
10° C to avoid frost risk. The electrical supply must be ac e ffor using this func on.
The control panel language is Turkish. Language also can be changed in English too.
540kW -
Condensing Boiler with Premix Burner
GENERAL BOILER DIMENSIONS
M: Water outlet connection: 2" F: Flue diameter: 200 mm
R: Water inlet connection : 2" G: Gas inlet : 1 ¼ “
540/
M: Water outlet connection : 3"
R: Water inlet connection : 3"
F: Flue diameter: 250 mm
G: Gas inlet : 2 ½ “
M: Water outlet connection : 4" F: Flue diameter: 250 mm
R: Water inlet connection : 4" G: Gas inlet : 2 ½ “
540kW -
Condensing Boiler with Premix Burner
OPTIONAL ACCESSORIES FOR COMFORT USE AND ENERGY SAVINGS
AVS37 USER INTERFACE
Selection of DHW heating
Heating mode selection
LCD screen
Information button
Service connection (USB)
Confirmation button for settings (OK)
Manuel control
Escape
Reset
Room comfort temperature
adjustment and navigation button
Chimney sweeper button (STB test)
You can adjust day - week program - holiday program - comfort program - economy - boiler setting - pool setting legionella function - solar collector - zone control - floor heating - cascade setting - winter and summer setting.
QAA55 Room Unit:
It has to be well placed where it can be
measure room temperature.
QAA75 Wireless Room Unit:
It has to be well palced where it can be measure
room temperature. You can adjust with this time
and day setting, operation unit (language selection),
time programming, holiday setting, heating unit,
DHW temperature, meintanence setting.
QAC345 Outside Air Sensor:
This is NTC type sensor. It can works between
-50°C to 70° C. Tolerance between +1 / -1K.
1,5mm² or 7,2mm diameter copper cable must
be use for connection. The allowed cable
lenght is 120 m.
QAZ36 Immersion Type
Sensor
This is NTC type sensor.
It can work between 0 - 95°C
Tolerance is +0,5 / -0,5 K.
QCI345 Cascade
Connection Unit
QAD36 Clamp Type Sensor
It can work between
-30°C to 125° C.
Tolerance is +0,5 / -0,5 K.
AVS82 Interface
Connection Cable
QZW672 Web Server
It can work with computer or smart phone via web. You can
have a possiblities of control via smart phones
AVS75 Additional Module
(iphone or android). You can put your system diagram into
Relay connections,
solar collector
connection, swimming pool
water heating and 3 way
valve connection can be
done with this unit.
OZW672 with ACS790 PC software. You will see trace the
system andinformations. You can control 1, 4 or 16
boilers depends on OZW model. There are a possibilities
of ethernet and USB port. There are 2 digital inlet for faulty
message. You can view faulty via web. It can sent a faulty
message up to 4 users. It can sent faulty massages with
e-mail to users via web periodically.
540kW -
Condensing Boiler with Premix Burner
HIGHER EFFICIENCY IN BOILER ROOM
WITH SMALL VOLUME AND HIGH CAPACITY
Higher efficiency with higher capacity cascade system with premix burner
Cascade possiblities up to 16 within order of 1 master and 15 slave boilers.
This system allows you work continuously even in any boiler faulty.
Long lasting boilers thanks to equal ageing system to make equal working time for system boilers.
You can save fuel with wide range modulating and condensing technology.
Comfort heating with room thermostat and outside air tepmperature control.
You can control every boiler, all zones, swimming pool heating and solar collector via web server.
540kW -
Condensing Boiler with Premix Burner
CASCADE CONNECTION SYSTEMS
Single boiler connection example scheme
Single boiler, heat exchanger and DHW tank connection
Double boiler cascade system
TECHNICAL SPECIFICATIONS TABLE
PRODUCT TYPE
540
General
Flue installation type
Fuel type - gas category
kW
Nominal heat input Qn
kW
Nominal heat output Pn (80-60) °C
kW
Nominal heat output Pn (50-30) °C
kW
81,9
Working pressure
Maximum working temperature
Limit thermostat shut down temperature
Combustion and Efficiency
Efficiency Q max (80-60) °C
Efficiency Q min (80-60) °C
Efficiency Q max (50-30) °C
Efficiency Q min (50-30) °C
Partial load %30 (return water 30) °C
Flue gas temperature (80-60) °C
Flue gas temperature (50-30) °C
CO2 emissions (80-60) °C
CO2 emissions (50-30) °C
CO2 emissions (80-60) °C
CO2 emissions (50-30) °C
NOx emissions G20
NO x class
Combustion products output mass
Gas consumption
Fan speed
Electric
Main supply
Connections
Boiler water outlet
Boiler water inlet
Boiler gas inlet
Condensation drainage
Air inlet connection
Chimney diameter
Dimensions
Weights
The distributor: