z Programmable ambient thermostat, mains, weekly ECO

/
1
z Programmable ambient thermostat,
mains, weekly ECO
$
User instructions
6LE001553A
This programmable ambient thermostat has been designed to bring you comfort and energy
economy. It allows you to program and regulate your heating system at 3 temperature levels :
- Comfort : this is the temperature you desire during the hours you are
present.
HQWUÆH
- Eco : this is the temperature you desire during short absences or atWKHUPRVWDWG
DPELDQFHGÆSRUWÆ
night.
- Frost protection : this is the guaranteed minimum temperature during your prolonged absences.
It protects your accommodation against the dangers of frost.
EK510
/
1
$
Product description
Electrical installation and connections
To guarantee its ambient temperature-regulation
function, the thermostat should be installed around
1.3 m above the ground, on an interior wall and
away from direct sunlight or any heat source such
as a television, lamp, radiator, draft, chimney, etc.
Fix the thermostat onto the flush-mounted casing
or in the slot without a casing intended for this
purpose.
4. Connect the product according to the wiring
diagram below.
5. Reclose the flap
6. Clip the front face onto the wall-mounted
base.
(LQJDQJ
Connection of 5DXPWKHUPRVWDW
the thermostat to a thermostat input on the boiler
/
1
$
–
ok
+
1 Context key for menu access
2 Context key for mode access holidays
3 Confirmation key OK
4 Adjustment keys + and –
30%
For optimum quality temperature regulation, seal
the flush-mounted casing or the electrical duct.
1. Separate the product from the wall-mounted
base, by pushing on the button located under
the base.
LQSXW
IURPUHPRWHDPELHQWWKHUPRVWDW
/
1
Connection of a heat circulator
/
1
3./
–
ok
$
+
$
$
LQJDQJ
NDPHUWKHUPRVWDDWRSDIVWDQG
5 Indicator for days of the week
6 Automatic mode/manual mode
2. O
pen the flap with the help of a screwdriver and
attach the wall-mounted base using the screws.
3. Next, pass the electrical cables into the holes
intended for this purpose.
This product must be installed
according to the local installation
standards in force.
(thermostat without program)
7 Temperature settings adjustment
8 Standby
9 Programming/program selection
A Time and date adjustment
Z Adjustment of settings
E Ambient temperature
R Heating indicator
T Current setting­­­ ( , , )
Y Temperature of current setting
U Profile of today’s program
I Current time
TOP
TOP
–
ok
+
16LE001553A
Initial adjustment and updating
Installer parameters
When the product is first used, the screen
offers the option to adjust the year, date and
time, without going into the parameter settings.
or
Press key 1 menu to place the cursor under
.
• The year flashes, press key 4 + the navigation key to adjust the current year. Confirm
using the OK key.
• The month flashes. Now press key 4 + or –.
Confirm using the OK key then proceed in
the same manner to select the day, hour
and minutes.
•A
UTO flashes. Press key 4 + to set the installation to switch automatically between
summer and winter time (auto) or not (off).
Confirm using the OK key.
•2
4 :H flashes. Press key 4 + and select
the 12 hour or 24 hour time format.
Confirm using the OK key.
To access all of the parameters (from PA:3 to PA:12), press key 1 menu to place the cursor under
then give one long press (>5s) sur OK.
Automatic mode (auto)
PA:12 - Software version
In automatic mode, the thermostat adapts
itself to the rhythm of your life by applying one
or more programs that you have selected.
• Press key 1 menu to place the cursor
under auto.
Key 1 menu allows you to return to auto
mode when the (holiday) program is running.
Manual mode (manu)
Manual mode transforms your equipment into
a simple thermostat. It allows you to maintain
a constant temperature in your accommodation
(adjustable from +5 °C to +30 °C) and ignores
the available program profiles.
• Press key 1 menu to place the cursor
under manu.
• Press key 4 + or – to adjust the desired
temperature.
Example : The desired temperature is at 22 °C
and the ambient temperature is 20 °C.
The heating-activated indicator R is illuminated.
PA:3 - Temperature calibration
This parameter lets you adjust the value displayed by the thermostat if you measure a different
ambient temperature to that which the thermostat measures.
• Press key 4 + or – to modify the temperature within a range of +/-3 °C.
Confirm using the OK key to pass to the next parameter.
PA:6 - Degumming the pump
This parameter allows you to activate/deactivate the automatic start-up of the pump at midnight everyday, in order to avoid its jamming during the summer.
• Press key 4 + or – to activate (ON) or deactivate (oFF).
Confirm using the OK key to pass to the next parameter.
Parameter PA:6 is set to OFF by default.
PA:10 - Return to factory settings
This parameter lets you return programs and parameters to the factory settings.
• Press key 4 + or – to choose Yes (reset) ou no (no reset).
Confirm using the OK key to pass to the next parameter.
This parameter displays which version of the software is installed in the product.
Press OK to exit from parameter adjustments.
User parameters
To access the user parameters, press key 1 menu to place the cursor under
the OK key.
and confirm using
PA:3 - Temperature calibration
This parameter lets you adjust the value displayed by the thermostat if you measure a different
ambient temperature to that which the thermostat measures.
• Press key 4 + or – to modify the temperature within a range of +/-3 °C.
Confirm using the OK key.
Once adjustment of this parameter is carried out, the thermostat switches to auto mode and takes
account of this modification.
Holiday mode
Standby mode
The heating system can be put on standby.
The thermostat is live and protects your installation if the temperature drops below
5 °C (fixed non-modifiable instruction). It displays the time, current day, ambient temperature and
Off information.
• Press key 1 menu to place the cursor
under .
OFf flashes.
• Confirm using the OK key.
• Press key 1 menu to exit standby mode.
This mode protects your accommodation against
the dangers of frost and maintains a minimum
temperature during your absences, which can be
adjusted between 5 °C and 30 °C. You can program
the duration of your absence to anticipate a rise
in temperature for your return.
• Press key 2 , and then key 4 + to select
the number of days absence (from 1 to 99 days).
The current day counts as 1.
Confirm using the OK key.
• The icon appears and the temperature to be
adjusted flashes.
• Press key 4 + or – to indicate the desired temperature value. Confirm using the OK key. Leave
the thermostat in this mode. To cancel and return
to automatic mode, press key 1 menu.
• To modify the duration of your absence or the
temperature value, press key 2
and proceed
to the changes.
Adjusting the temperature set-points
The temperatures are preset :
Comfort = 19 °C, Eco = 16 °C.
The adjustment range for the heating settings
is from 5 °C to 30 °C.
Modification of the Comfort temperature
• Press key 1 menu to place the cursor under .
The Comfort temperature
flashes.
• Press key 4 + or – to modify the temperature.
Confirm using the OK key.
Modification of the Eco temperature
• The Eco temperature flashes.
• Press key 4 + or – to modify the temperature.
Confirm using the OK key.
26LE001553A
Programming
Four programs are available to program your
week : P1, P2, P3 which are pre-recorded and
not modifiable and P4 which is free and allows
you to create a personalised program that can
be different for each day of the week.
Creation of a personalised program P4
This program allows you to adjust the heating
to suit your way of life.
A 24-hour profile is composed of 48 points
(representing the set-points). You can visualise
the composition of your program at the bottom
of the display. 1 program step = 30 minutes.
P1 = Comfort temperature from 06 :00 to 23:00.
Eco temperature from 23:00 to 06:00.
P
1 is activated 7 days per week
by default. If this fits the rhythm
of your life then remain in automatic
mode; if not, continue.
P2 = Comfort temperature from
06:00 to 08:30 and from 16:30 to 23:00.
Eco temperature from
08:30 to 16:30 and from 23:00 to 06:00.
P3 = Comfort temperature from
06:00 to 08:30, from 11:30 to 13:30
and from 16:30 to 23:00.
Eco temperature from
08:30 to 11:30, from 13:30 to 16:30
and from 23:00 to 06:00.
P4 = a free program which allows you to
create up to 5 Comfort temperature
periods and 5 Eco temperature periods,
for each of the days of the week.
Assigning an existing program (P1, P2 or
P3) to one or more days of the week
You can assign any of the programs to all
7 days of the week, to a group of five weekdays, to a group of two days for the weekend
or to an individual day.
• Press key 1 menu to place the cursor
under prog. The indicators for the seven
days of the week flash.
• Press key 4 + to select which day, or group
of days, to assign a program to.
Confirm using the OK key.
• P1 flashes. Press key 4 + to select the
program to apply.
Confirm using the OK key.
As an example, to assign P2 to the group
of five weekdays and P1 to the group of two
weekend days :
• Press key 1 menu to place the cursor
under prog. The indicators for the seven
days of the week flash.
• Press key 4 + to select to affect the group
of five days (the group of five days flashes).
Confirm using the OK key.
• P1 flashes. Press key 4 + to select
(P2 flashes). Confirm using the OK key.
• Press key 4 + to select the group of
2 weekend days (the group of 2 weekend
days flashes).
Confirm using the OK key.
• P1 flashes. Confirm using the OK key.
The thermostat returns to auto mode.
30 min. in Eco
30 min. in Comfortv
Example : creating a program, P4, for a group
of days (5 weekdays + 2 weekend days).
For the 5 weekdays, we would like 3 Comfort
periods from 06:00 to 08:00, from 12:00 to 14:00
and from 18:00 to 22:00.
For the two-week in days, we would like one
Comfort period from 08:00 to 22:00.
• Press key 1 menu to place the cursor under
prog. The indicators for the seven days of the
week flash.
• Press key 4 + to select to affect the group of
five days (the group of five days flashes).
Confirm using the OK key.
• P1 flashes. Press key 4 + to select P4
(P4 flashes). Confirm using the OK key.
• Press key 1
until 6 :00 appears and key 2
until
until 8:00 appears. Next press key 1
12:00 and key 2
until 14:00. Then press key
1 until 18:00 and finally key 2 until 22:00.
If you make an error, press key 4 – to move back
or key 4 + to advance and correct your programming.
• Confirm using the OK key.
• The group of 2 weekend days flashes.
Confirm using the OK key.
•P
1 flashes. Press key 4 + to select P4
(P4 flashes). Validez avec la touche OK.
• Press key 1 until 8:00 is reached and
then press key 2
until 22:00.
Confirm using the OK key.
Note :
The latest P4 program is held in memory and
automatically offered to be assigned to a new day
or group of days (whose P4 is empty).
Technical characteristics
Power supply : 230V v +10/-15% 50 Hz
240V v +/-6% 50Hz
Power reserve : 4 hours
Static differential (On/Off regulation) : < 0.3 °C
Adjustment range
- Comfort temperature : +5 °C to +30 °C
- Eco temperature : +5 °C to +30 °C
Ambient temperature display range :
0 °C à +40 °C
Operating temperature : 0 °C to +45 °C
Storage temperature : -25 °C to +70 °C
Ball test temperature : 75°C and 125°C
Clock operating accuracy : drifts < 1sec/day
Trip values : 230V v 5A resistive / 3A inductive
Minimum load excepted by the relay : 12V/10mA
Relative humidity : 90 % at 20°C
IP : 30
Ecodesign class :
4
IK : 04
Insulation class : II
Insulation type : 4 kV
Rigid cable cross-sections : 0,5 to 2.5 mm²
Flexible cable cross-sections : 0,5 to 1.5 mm²
Minimum pulse voltage : 4 kV
Pollution class : 3
Action type : 2B
Insulation type : reinforced insulation
Software structure : class A
Voltage and current declared for the needs of
EMC emissions tests :
230V v 0,5A
Upstream protection: circuit breaker 6A
Independent installation device for built-in
installation
Temporary override
By overriding until the next program step
In auto mode, it is possible to modify the
temperature of the current set-point.
• Press key 4 + or – to increase or decrease
the displayed set-point temperature.
The set-point temperature flashes and the
override is valid until the next program step.
During the override period, the current set-point
temperature flashes.
What to do if... ?
There is no display :
check the connection to your thermostat.
Correct Disposal of This product
(Waste Electrical & Electronic
Equipment)
( Applicable in the European Union and other European
countries with separate collection systems).
This marking shown on the product or its literature
indicates that it should not be disposed with other
household wasted at the end of its working life. To
prevent possible harm to the environment or human
health from uncontrolled waste disposal, please
separate this from other types of wastes and recycle it
responsibly to promote the sustainable reuse of
material resources. Household users should contact
either the retailer where they purchased this product,
or their local government office, for details of where
and how they can take this item for environmentally
safe recycling.
Business users should contact their supplier and
check the terms and conditions of the purchase
contract. This product should not be mixed with other
commercial wastes of disposal.
­Usable in all Europe
å and in Switzerland