The 4100-LR Series faucet is a single-hole deck mounted,
piston operated sensory faucet that provides a vandal
resistant, low lead, no touch solution with integral hot/
cold ceramic mixing and manual on/off adjustment that
promotes better hygiene and energy savings.
Designed to be easy to install and maintain, all major
faucet components are encased above deck, making
for easier access. The sensor included in this faucet is
self adapting, meaning manual adjustments are not
necessary.
•
•
•
•
•
•
•
•
ADA Compliant. Meets all barrier free codes
Conserves water and energy
Easily installed in new or retrofit applications
Competitively priced for today’s commercial market
Promotes cleanliness & hygiene
Proven Hydrotek craftsmanship and reliability
Temperature adjusting handle with manual on/off
Low Lead
Available in:
9
Low Lead, AC Powered (H-4100-LR)
9
Low Lead, Battery Powered (HB-4100-LR)
Features:
•
Vandal-resistant faucet body with chrome plated,
•
models)
solid brass construction.
•
•
Faucet design allows quick “above the deck”
•
•
•
•
Single-hole deck mounting with optional 4” and
access to all major faucet component parts.
8” cover plate for vandal resistant, three point
30 second time-out feature prevents accidental
anchoring.
sink overflow.
•
Low battery indicator light (battery powered
•
Manual override provides continuous water
Integrated ceramic faucet mixing valve (with built-in
flow for special applications or in case of power
checks) allows for precise hot/cold mixing.
failure.
“Above the deck” external or internal temperature
•
Manually controlled temperature adjustment.
adjustment variation.
•
Patented electronics and slow closing solenoid
Standard 2.2 GPM flow control for water
valves provide reliable and smooth operation
conservation and annual savings.
without water hammer.
“Self-adapting” sensor distance adjustment
•
Includes in-line filter adapter for easier cleaning.
eliminates need for manual sensor adjustments.
•
Superior VSI silicone elastomer piston seals are
unaffected by chlorine, chloramines, or ammonia.
Hydrotek Automatic Faucets
4100-LR Series
Deck Mounted / Mixing
Meets ANSI/ASME A112.18.1 M-1989
4100-LR
HYDROTEK INTERNATIONAL, INC.
5055 Forsyth Commerce Rd., Ste 124
Orlando, FL 32807
800.922.9883 (Phone)
866.670.5580 (Fax)
www.hydrotekintl.com
Operation:
1. A continuous, invisible beam is emitted from the sensor.
2. The faucet is activated by placing hands under the spout within
the effective range of the beam. Water starts to flow immediately
for as long as the user’s hands remain in the sensor range.
3. When hands are removed, the water flow stops. The sensor will
automatically reset and be ready for the next user.
4. Water temperature adjustment can be easily accessed with
external adjuster.
Specifications:
Faucet Construction: . . . . . . . . . Solid brass, chrome plated
Control Circuit:
Auto. Time-out: . . . . . . . . . . . 30 seconds
Sensor Range: . . . . . . . . . . . . . Self adapting
Shut-off Delay: . . . . . . . . . . . . 1 second
Solenoid Valve: . . . . . . . . . . . . . . 6V DC, normally closed
Wattage: . . . . . . . . . . . . . . . . . 0.2W (idle), 3W (in use)
Operating Pressure: . . . . . . . . 5 psi to 125 psi
Flow Control: . . . . . . . . . . . . . . . 2.2 GPM, Laminar, Vandal Resistant
AC Mode
Power Adapter (UL/CSA)
Standard Plug-in: . . . . . . . . . . Input AC 120V 60 Hz or 220V
Output DC 7.5V, 0.8A/Class 2
Power Cable:. . . . . . . . . . . . . . Armored, vandal resistant
Optional Multi-Unit Adapter: . . Serves up to 6 faucets
(UL/CSA)
Input AC 120V, Output DC 7.5V, 3A
Battery Mode
Battery Powered Models: . . . . . (4) AA Alkaline Batteries
Battery Service Life: . . . . . . . . . . 400,000 on/off cycles, up to 4 years
Warranty: . . . . . . . . . . . . . . . . . . . . 3 years
Package Includes:
(1) Faucet with sensor/solenoid
(1) 6” Gooseneck spout
(1) Armored S.S. supply tube with filter
(1) Mounting hardware
(1) 2.2 GPM Laminar Flow Control
(1) 7.5V DC plug-in power adapter (H-4100-LR only)
(4) AA Alkaline batteries (HB-4100-LR only)
Dimensions:
Base Width (Outside Measurement) . . . . .4-7/16”
Base Depth . . . . . . . . . . . . . . . . . . . . . . . . . .2-1/16”
Faucet Height (Aerator to Base) . . . . . . . . .6-7/8”
Faucet Height Overall . . . . . . . . . . . . . . . . .10-1/2”
Depth (Aerator to Base). . . . . . . . . . . . . . . .5-5/8”
Mounting Bolt Length . . . . . . . . . . . . . . . . .2”
Mounting Bolt Pattern . . . . . . . . . . . . . . . . .Single-hole mount
Optional Variations and Accessories
• 0.35, 0.5, 1.5, 2.0 GPM Laminar Flow Control
• HC-010E Multi-Unit Voltage Adapter (AC Powered Only)
• Different spout styles and sizes available upon request
• 4” or 8” Centerset Cover Plate
• HBL-04 Thermostatic Mixing Valve with Check
HB-4100-LR
HB-4100CLR
DC Powered Sensor Operated Mixing
AC Powered
Faucet Sensor Operated Mixing Faucet
ISO 9001 Certified
Installation Instructions Installation Instructions
Installation Instructions:
1. The spout nut(2) and spout gaskets(3) will come assembled on the
spout(1). Insert the spout into the receptacle on the body(4) and
tighten down the spout nut(2) to secure the spout.
2. Remove the washer(7) and lock nuts(8) and slide the faucet supply
rods through the deck hole. If there are 3 holes, use the cover
plate(4”or 8”) from Hydrotek, call 800-922-9883. If desired, slide
the wire bracket(12) onto a mounting rod(5). Tighten faucet to
deck using washer(4) and lock nuts(5).
3. Connect in-line filters(10) to the supply tubes and the in-line filters
to the stop valves. A 3⁄8” union connector (provided by others) is
required to connect the inline filters to the stop valves.
4. Insert 4 AA batteries into the battery holder(11) and attach the
battery holder(11) to the power connector(6). Wait 10 seconds for
the sensor to self-adjust, then place hand in front of spout, it should
click. If not, check the connection between the AC connector and
plug-in adapter.
5. Turn on water from the stop valve and check for leaks.
6. Place hand in front of the sensor eyes, water should start to flow.
Remove hands, water stops.
7. IMPORTANT: The control stop valve should never be opened to
the point where the flow from valve exceeds the flow capability of
the sink fixture. In the event of a valve failure, the sink fixture must
be able to accommodate a continuous flow from the valve.
8. IMPORTANT: This product contains mechanical components that
are subject to normal wear. Periodical maintenance is required in
order to maintain the faucet performance.
9. DO NOT USE abrasives, acids or cleaning fluids to clean Hydrotek
Sensor faucet . Use only soap and water then wipe with clean
cloth or towel.
Parts:
1. Gooseneck Spout
8. Lock Nuts
2. Spout Nut
9. Supply Tubes
3. Spout Gasket
10. Inline Filters
4. Body
11. Battery Holder
5. Mounting Rod
12. Wire Bracket
6. Power Connector
13. Battery Connector
7. Washer
HYDROTEK INTERNATIONAL, INC.
5055 Forsyth Commerce Rd., Ste 124
Orlando, FL 32807
800.922.9883 (Phone)
866.670.5580 (Fax)
www.hydrotekintl.com
4100-LR Series
Sensor Operated Mixing Faucet
Troubleshooting Guide
Normal Operation: When power is connected, the faucet will immediately perform diagnostic function. You
will hear a clicking sound and see lights flash. When the user’s hands are placed under the spout, the light
will flash once and water will start to flow. Water flow will stop when hands are removed. The red indicator
light will flash when the batteries are low.
Turn the manual handle clockwise to increase temperature and counter-clockwise to decrease.
Problem
Faucet will not turn on:
Possible Cause
To Diagnose
Remedy
Power supply failure
No light, no clicking:
•Check batteries
•Check power adapter
Reinstall or replace batteries/
Replace power adapter
Low battery
Light continues to flash
Replace batteries
Electronic PCB / Sensor is
defective
No light, no clicking:
•Reinsert batteries
•Reattach power adapter
Replace electronic PCB
Solenoid valve is clogged
Solenoid is clicking but no water
is coming out
Clean solenoid
In-line filter is clogged
Open clean-out trap and check
filter screen
Clean or replace filter screen
Solenoid coil is defective
Insert new batteries or reattach
power adapter. Light blinks but
no solenoid is clicking
Replace solenoid coil
Flow control is clogged
Open flow control device and
check
Celan the flow control device
Water not turned on
Check water supply
Turn water on
Faucet will not shut off, The solenoid valve is normally closed. Turn off water and activate the faucet. If there is a clicking
sound, the solenoid valve is dirty. If there is no clicking sound, then check the solenoid valve. If
has low glow, or drips: the faucet is dripping, clean the solenoid valve.
IMPORTANT: Periodic maintenance is required for smooth and trouble-free operation of this faucet.
For service and inquiry about available repair kits, please call Hydrotek Technical Support at (800) 922-9883.
4100-LR Series
Sensor Operated Mixing Faucet
Maintenance Tasks
PRESSURE RELEASE VALVE REPLACEMENT
1. Disconnect power by disconnecting the AC adapter
or battery pack underneath the faucet.
2. Unscrew the Body Set Screws and with an upward
motion, pull the the upper faucet body off of the
faucet base.
Control Module
Pressure Release
Valve Assembly
3. Disconnect the connector for the Pressure Release
Valve Assembly.
4. Unscrew the Pressure Release Valve Assembly and
remove it from the upper faucet body.
5. Install the new Pressure Release Valve and reassemble the faucet in reverse order.
Body Set Screws
Retaining
Rods
CONTROL MODULE (P.C. BOARD) REPLACEMENT
1. Disconnect power by disconnecting the AC adapter
or battery pack underneath the faucet.
2. Unscrew the Body Set Screws and with an upward
motion, pull the the upper faucet body off of the
faucet base.
3. Disconnect the connector for the Pressure Release
Valve Assembly.
4. Unscrew the Retaining Rods and pull them up and
out from the faucet base.
5. Remove the Control Module.
6. Install the new Control Module and reassemble the
faucet in reverse order.
For further questions, please call Hydrotek Technical
Support at (800) 922-9883.
4100-LR Series
Sensor Operated Mixing Faucet
Assembly Parts
No Description
1 Gooseneck Spout
1
2
Part Number
H41-001
2
Ceramic Cartridge
H41-002
3
Power Adapter (AC Only)
HCE-008
4
Pressure Valve Assembly
H41-004
5
Sensor/Control Module Assembly H41-005
Please visit our website, www.hydrotekintl.com, for our
most current Products Pricing Sheet.
5
4
3
AC Powered
Only