www.marleypipesystems.co.za
MARLEY
Hot & Cold
Water
Showcase
INDEX
INTRODUCTION
.............. 02
PRODUCTS
LATCO
.............. 03 - 05
Pro-Fit
.............. 06 - 10
TECHNICAL VIEW
LATCO
.............. 13
Pro-Fit
.............. 14
CASE STUDY
.............. 15 - 16
MARKETING
LATCO
.............. 03
.............. 06
Pro-fit
FAQ
SUPPORT
.............. 17
TRAINING
.............. 18
CONTACT US
.............. 19
INSTALLATION
LATCO
.............. 12
.............. 12
Pro-fit
Southern African Vinyls Association
01
INTRODUCTION
YOUR EXPERIENCED PARTNER IN FLUID
HANDLING SOLUTIONS
Marley Pipe Systems, an Aliaxis
company, is recognised as the trusted name in fluid handling solutions
throughout southern Africa, offering
an extensive range of pipes and fittings, and related products that set
the standard for quality, compliance
and customer satisfaction in the
plumbing and building market.
For over five decades, we have
served as a dynamic partner with
integrity for our clients, our people,
our suppliers and our market. The
capacity to supply a comprehensive, quality focused product range
coupled with the ability to provide
a complete merchandising solution and product support structure
is what sets us apart.
It is these values of quality and
service that continue to define us
as a company as we consistently strive to deliver high level customer experiences throughout the
value chain from factory floor to
end-consumer and everything in
between.
Southern African Vinyls Association
www.marleypipesystems.co.za
02
LATCO PRESSURE
REGULATING VALVES
Convenience and quality in one SYSTEM
LATCO presents a reliable generation of pressure regulating valves and pressure control valves for hot and cold water systems that saves time and money, offering maximum value at unbeatable prices.
Manufactured from a tough, corrosion resistant Acetal copolymer, LATCO Standard
has been in use for over 35 years on a substantial number of dwellings without change
to its principal design. The benefits of plastic over copper and brass alternatives is
that there is no electrolytic action with the water and no scale build up. Another key
advantage of LATCO valves is that they have no scrap value meaning that there is less
pilferage from merchants and building sites.
The range is available in 100kPa, 200kPa, 400kPa and 600kPa models for both BSP
and CC connections, and is compatible with all SANS 151 compliant hot water cylinders.
1. LATCO Neptune
2
Pressure Control Valve
2. LATCO Expansion
1
Relief Valve
3
5
4
3. Hot Water Cylinder
4. Temperature &
Pressure Safety Valve
10
6
with separate
5. LATCO Vacuum
Breaker
9
11
7
6. Hot Water Pipe
7. Drip Tray
8. Pipework to Mixer /
Taps
8
9. Drip Tray Outlet Pipe
10. Cold Water Inlet Pipe
11. Stopcock
03
www.marleypipesystems.co.za
LATCO PRODUCT
RANGE
STANDARD LATCO - 100KPA
LAT27
Twin Pack
LAT25
Pressure Control Valve
LAT26
Relief Valve
NEPTUNE BLUE - 100KPA
LAT12
Twin Pack - BSP
LAT10
Pressure Control Valve
- BSP
LAT11
Relief Valve - BSP
NEPTUNE BLACK - 200KPA
LAT15
Twin Pack - BSP
LAT13
Pressure Control Valve
- BSP
LAT14
Relief Valve - BSP
www.marleypipesystems.co.za
04
LATCO PRODUCT
RANGE
NEPTUNE RED - 400KPA
LAT18
Twin Pack - BSP
LAT16
Pressure Control Valve
- BSP
LAT17
Relief Valve - BSP
LAT18C
Twin Pack - CxC
LAT18CON
“Contractor’s Pack”
Including Relief Valve
and Vaccuum Breaker
NEPTUNE GREEN - 600KPA
LAT602
Twin Pack - BSP
LAT600
Pressure Control Valve
- BSP
LAT601
Relief Valve - BSP
VACCUUM BREAKER
LAT49
Double Seat, Brass
Body - 20mm - BSP
05
www.marleypipesystems.co.za
PRO-FIT POLYMER
SYSTEM
Leveraging advantages in material technology
Pro-fit is a complete hot and cold water supply solution that is suitable for residential and
commercial installations, offering contractors ease of use and up to 50% time savings on
installations. This revolutionary hot and cold technology requires minimal training, is cost
effective and offers many advantages, some of which include:
○
○
○
○
Corrosion & impact resistance
No scale build up
Quieter plumbing
Healthier water
○
○
○
○
No scrap value
Decreased turbulent flow
Low co-efficient of friction
100% certain joints
Manufactured from the highest grade PE-RT (Polyethylene with Raised Temperature Resistance), Pro-fit is tough, puncture and tear resistant and offers greater flexibility with a
bending radius of up to 180°, allowing ease of use and the reduction in the use of fittings
required.
11
www.marleypipesystems.co.za
06
PRO-FIT
PRODUCT RANGE
PRO-FIT PIPE
PRP016006
Pipe 16mm length 6m
PRP020006
Pipe 20mm length 6m
PRP016050
Pipe 16mm Coil 50m
PRP020050
Pipe 20mm Coil 50m
PRESSURE SLEEVES
PRFSL16
Pressure Sleeve 16mm
PRFSL20
Pressure Sleeve 20mm
COUPLINGS
PRFCP16
Coupling Equal 16mm
PRFCP20
Coupling Equal 20mm
PRFCPR2016
Coupling Reducing
20mm-16mm
ELBOWS
07
PRFEL16
Elbow 90° 16mm
PRFEL20
Elbow 90° 20mm
PRFEF1612
Elbow 90° Female
16mm - 1/2”
PRFEC1615
Elbow 90° Copper
Adaptor 16mm - Cu 15
PRFEM1612
Elbow 90° Male
16mm - 1/2”
www.marleypipesystems.co.za
PRO-FIT
PRODUCT RANGE
TEEs
PRFTE16
Tee Equal 16mm
PRFTE20
Tee Equal 20mm
PRFTC161516
Tee Copper Adaptor
16mm - Cu 15 - 16mm
PRFTR161620
Tee Reducing
16mm-16mm-20mm
PRFTR202016
Tee Reducing
20mm-20mm-16mm
PRFTR201616
Tee Reducing
20mm-16mm-16mm
PRFTR201620
Tee Reducing
20mm-16mm-20mm
PRFTM161216
Tee Male Branch 16mm
- 1/2”
connectors
PRFCM1612
Connector Male 16-1/2”
PRFCM1634
Connector Male 16-3/4”
PRFCM2012
Connector Male 20-1/2”
PRFCM2034
Connector Male 20-3/4”
PRFCF1612
Connector Female 161/2”
PRFCF1634
Connector Female 163/4”
PRFCF2012
Connector Female 201/2”
PRFCF2034
Connector Female 203/4”
PRFCC1615
Copper Adaptor 16mm Cu 15
PRFCC2022
Copper Connector
20mm - Cu 22
www.marleypipesystems.co.za
08
PRO-FIT
PRODUCT RANGE
EXTENSIONS
PRFEX1215
Extension 1/2” - 15mm
PRFEX1210
Extension 1/2” - 10mm
PRFEX1225
Extension 1/2” - 25mm
PRFEX1220
Extension 1/2” - 20mm
END PLUGS
PRFPL20
End Plug 20mm
PRFPL16
End Plug 16mm
WALL OUTLETS
PRFOS1612
Wall Outlet 16mm - 1/2”
PRFOS2034
Wall Outlet 20mm - 3/4”
PRFOD90
Double Entry Wall Outlet
- 90° 16mmx1/2”
PRFODPL
Double Entry Wall Outlet
- Parallel 16mmx1/2”
REMS - FLARING TOOLS
PRTEXT1620
Pipe Flaring Tool (Incl. 16mm & 20mm Expanding Jaws)
PRTEXJ16
Expanding Jaws 16mm
PRTEXJ20
Expanding Jaws 20mm
PRTEXT
Pipe Flaring Tool Only
09
www.marleypipesystems.co.za
PRO-FIT
PRODUCT RANGE
VULCAN - CLOSING TOOLS
PRTCLT1620
Pressure Sleeve Closing Tool (Incl 16mm & 20mm Jaws)
PRTCLJ16
Pressure Sleeve Jaws 16mm
PRTCLJ20
Pressure Sleeve Jaws 20mm
PRTCLT
Pressure Sleeve Closing Tool Only
REMS - CLOSING TOOLS
PRTCLT1620REMS
Pressure Sleeve Closing Tool (Incl 16mm & 20mm Jaws)
PRTCLJ16REMS
Pressure Sleeve Jaws 16mm REMS
PRTCLJ20REMS
Pressure Sleeve Jaws 20mm REMS
PRTCLTREMS
Pressure Sleeve Closing Tool Only REMS
DUAL PLATE UNIVERSAL
PRFDAR
Dual Plate Universal Recessed
PRFDAF
Dual Plate Universal - Assembly Unit
SINGLE PLATE
PRFSAR
Single Plate Recessed
PRFSAF
Single Plate - Plastic
PRFSARO
Single Plate - Recessed
www.marleypipesystems.co.za
10
INSTALLATION
LATCO high pressure control and expansion relief valves
should only be installed with SABS approved pressurised
electric geysers of the corresponding pressure rating. See
diagram on the next page for further instruction.
By following the installation guidelines below you are
guaranteed a high-performing result and many years of
trouble-free use.
1.
2.
3.
4.
5.
6.
LATCO Neptune 100, 200, 400 and 600kPa Twin Packs are
factory pre-set and need no adjustment.
Valves must be installed above the geyser. By doing so, it is
not necessary between the LATCO pressure control valve and
the geyser.
Fitting the expansion valve vertically will reduce the possibility
of dirt lodging in the valve.
As heating takes place, the water in the geyser will expand and
cause intermittent dripping from the expansion valve – this is
normal.
The drain from the valve should be protected against freezing
and should be discharged downwards into a gulley, flower bed,
etc., where expansion drip will not cause annoyance. On no
account should expansion drip be discharged over a paved
area or directly into waste, soil or vent pipes.
Where very high mains pressure exists, rigidly fix inlet cold
water supply pipe as close to the valve as possible to prevent
vibrations.
7.
After initially filling the geyser, close the cold water mains
supply and clean all hemp, pipe cuttings, etc., from the valve
filter. The filter may be removed for cleaning by unscrewing
the cap marked ‘filter-sif’ on the inlet side of the valve.
8. Where hot and cold water feeds to mixing points are not balanced, fit a non-return valve on the hot water draw off line to
prevent high pressure cold water being forced back through
the system. This fitting must not be installed between the
vacuum and geyser outlet.
9. A 25mm expansion pipe must extend at least 2.5m vertically
above both the valve and the highest hot water draw off point
from the geyser.
10. With all hot taps closed, adjust the water level in the expansion pipe by slowly turning the adjusting nut clockwise, until
all water flows out of the expansion pipe, then turn the adjusting nut back one full turn.
11. Provide air breaks if the drain:
o
Exceeds a 6 metre run
o
Drops more than 1 metre
o
Runs horizontal after a fall
2
1
6
7
6
3
9
8
4
10
5
www.marleypipesystems.co.za
11
LATCO
FAQs
Can LATCO Neptune valves be
used on unbalanced systems?
Yes, however we recommend
that the system be changed to a
SANS 10254 balanced system.
Which pressure valve should I
use for my system?
The rated pressure of the valve
must match the rated pressure of
the geyser. The pressure rating of
the valve is indicated by colour,
i.e. Blue: 100kPa, Black: 200kPa,
Red: 400kPa, Green: 600kPa.
Why does my LATCO flying
saucer leak?
The cause would have to be
diagnosed further, however
possible causes could be a faulty
valve or incorrect installation.
I fitted a new valve yesterday –
why is it leaking?
If the valve is leaking, there may
be dirt in the valve that needs to
be flushed and cleaned.
Are LATCO valves SABS approved?
Yes, LATCO Neptune valves are
SABS approved, however the
LATCO Standard valve (100kPa)
is not.
Can LATCO valves be used on a system
with an uncontrolled heat source?
No LATCO is not to be used on
systems with an uncontrolled
heat source.
Is it true that you only need to purchase
one vacuum breaker when using the
Neptune Twin Pack?
Yes, because the LATCO Expansion Relief Valve incorporates a
vacuum breaker function.
www.marleypipesystems.co.za
13
PRO-FIT
FAQs
What tools are required to join
Pro-fit pipes?
No consumables, heat or electricity are required to join Pro-fit
pipe – only a pipe cutter, an
expanding tool and a closing
tool. NB: a hacksaw should not
be used to cut Pro-fit pipe.
Can connection to copper pipes
be made?
Yes. By using a transition fitting,
you can easily connect a plastic
Pro-fit pipe to an existing copper
pipe.
Is the Pro-fit system SABS approved?
14
Yes, Pro-fit pipes and fittings
carry the SABS mark for
SANS10508.
Can Pro-fit pipes be installed in a
solar geyser set up?
Pro-fit should not be installed
outside to connect a solar geyser
as pipes are not UV stabilised
and would require additional protection to prevent deterioration
from the sun.
Can Pro-fit be used with gas geyser
systems?
No. It is not recommended to use
Pro-fit pipe in gas installations.
Do Pro-fit pipes need to be insulated to
prevent heat loss?
Pro-fit PE-RT pipe demonstrates
lower thermal conductivity than
mild steel and copper pipes,
however it is still recommended
to use the same precautions
against heat loss as required by
plumbing codes, regulations and
bylaws.
When should pressurisation occur
when installing Pro-fit pipe?
The process of pressurising the
line can take place immediately
after a joint has been made.
www.marleypipesystems.co.za
CASE STUDY:
PRO-FIT HOT & COLD WATER
SYSTEM, JOHANNESBURG CBD
Reaching new heights of delivery
In recent years, Joburg has been on a drive to
regenerate its inner city to better accommodate its current and future residents. As part
of this huge regeneration strategy, a number
of old and dilapidated high rise buildings are
being completely stripped and converted into
living apartments in areas such as Braamfontein, Joubert Park, Yeoville and Doornfontein.
During construction, there were a number of
factors that would influence the successful
completion of each and every project, one of
which was the choice of plumbing system. Operating in areas where the crime rate is high,
copper parts had to be ruled out due to theft
risks on site.
Pro-fit is helping to reduce those risks by offering a polymer-based range of products that
make up the hot and cold water system for
multi-storey buildings.
THE CHALLENGE
Marley was initially involved in the project to
convert a 17 storey building from copper to
Pro-fit. The success of this particular project
led them to secure a contract for the next
building to be renovated, a 29 storey behemoth that would serve over 450 living apartments.
Providing hot and cold water to the upper
floors of high rise buildings like this is a fundamental requirement and the main challenge
for plumbing system engineers who must consider a number of variables such as available
municipal water pressure, flow demand, pipe
and valve materials, riser locations, pressure
regulating stations not to mention economics
and even acoustics.
Requirements:
 Safe and reliable hot and cold water plumbing solution
 Quick and hassle-free installation and maintenance
One System.
Countless Satisfied End Users
29
16
450
Storey
Building
Apartments
per Floor
Total
Apartments
www.marleypipesystems.co.za
15
Helping Joburg meet its promise
for a better future
A winning system for high rise buildings
Ensuring value for years to come
For the project, Pro-fit was used as part of a fusion
PPR (Polypropylene Random) plastic piping system
to supply water throughout the building. The lower
storeys are supplied directly from the pressure in the
public water main while the upper storeys are supplied
from pressure-boosted main risers through a pressure
reduction valve for each group.
For Marley, working on big projects like this one is never just about the sale, it’s about ensuring sustainable
installations that add value to everyone it touches. To
this end, Marley was closely involved in the project to
make sure that contractors and installers had access
to expert advice at all times. This included the provision of training to each project team to help familiarise
them with the product so that they would be comfortable using it. On-site technicians were also available
to provide fault-finding support for any installation
troubles that were encountered.
PE (Polyethylene) has been widely used for the safe
transport of potable water for more than 35 years with
no harmful leaching of elements into the supply line.
Added to this track record, The Pro-fit system is JASWIC approved and has been tested and rated in accordance with SANS ISO22391 for hot and cold water
supply systems. The ingenuity in design and material
properties of the system offered many benefits for the
project:





Ease of installation
Increased reliability
Reduced costs
Reduced noise levels
No scrap value
The Final Result
Although the project is still in progress, the outcomes
of the installations so far have demonstrated the Profit system’s powerful capabilities.
The contractors were impressed by
the ease of use, hassle-free operation and cost-effectiveness of the
system, as well as the value-added
service that was provided. So much
so that they are keen to work with
the Pro-fit system and Marley
again in their next renovation –
this one, a 19 storey building.
For the latest product information
and local distributors, visit
www.marleypipesystems.co.za
16
www.marleypipesystems.co.za
MARKETING
SUPPORT
Your success is ours, so we make sure you’ve got support in all sorts
of ways
An important part of our business philosophy is to build good partnerships and trading relationships with our customers. To do this, a large portion of our service offering is dedicated to providing support for merchants, partners and
end users alike.
So, not only can partners have full confidence in a brand that customers trust, but they will also have access to sales
and marketing support, strategic guidance and merchandising plans that help optimise profitability by moving products off the shelf quicker.
○
○
○
○
Dedicated account service and knowledgeable product support
Access to a library of support catalogues and product literature
POS display and merchandising solutions tailored to your own needs
Promotional campaigns to drive customer adoption
LATCO PRESSURE
REGULATING VALVES
Marley’s trusted polymer system for pressure
control in hot and cold water systems
LATCO Standard
FREQUENTLY ASKED
QUESTIONS
Pressure Spring
Shut-off Seat 8mm
KEY FEATURES
15mm BSP Male Inlet
1. Can LATCO valves be used on
SANS 10254 balanced systems? Yes.
2. Can LATCO Neptune valves be used
on unbalanced systems? Yes, however
we recommend that the system be
changed to a balanced system.
3. What pressure valve must I use? The
rated pressure of the valve must match the
rated pressure of the geyser.
4. How can I identify the pressure class
of a LATCO valve? The pressure rating
of the valve is indicated by colour,
i.e. Blue: 100kPa, Black: 200kPa,
Red: 400kPa, Green: 600kPa.
5. WhydoesmyLATCOflyingsaucer leak? The cause would have to be
diagnosed further, however possible
causes could be a faulty valve or incorrect
installation.
6. Ifittedanewvalveyesterday–whyis
itleaking?If the valve is leaking, there
may be dirt in the valve that needs to be
flushedandcleaned.
7. Whyisthevalvemakingafunny
noise? Pressure and air in the valve may
cause it to make a noise.
8. Are LATCO valves SABS approved?
Yes, LATCO Neptune valves are SABS
approved, however the LATCO Standard
valve (100kPa) is not.
9. Can LATCO valves be used on a
system with an uncontrolled heat
source? No LATCO is not to be used on
systems with an uncontrolled heat source.
10.Is it true that you only need to
purchase one vacuum breaker when
usingtheNeptuneTwinpack?Yes,
because the LATCO expansion relief valve
incorporates a vacuum breaker function.
Adjusting Nut
Time proven simplicity of
design and reliable operation
20mm BSP Female Outlet
D3 Diaphragm 150mm
Manufactured from tough,
corrosion resistant Acetal
copolymer
LATCO Neptune
Most affordable pressure
regulating valve on the market
Can be installed with an open
standpipe or with a relief valve
Outlet 20mm BSP Male
Inlet 20mm BSP Male
Balance Piston
Balance Piston Sleeve
BENEFITS:









LATCO Expansion
Relief/Vacuum Breaker
Available as BSP or CC
connections
Easy installation
Available countrywide
Proudly manufactured in South
Africa
No theft risk – no copper parts
Corrosion-free
No scale build up
Compatible with all SANS 151 hot
water cylinders
UV stabilised
20mm BSP Male Outlet
Adjusting Spindle
Pressure Spring
Expansion Relief and
Vacuum Breaker Seat
Diaphragm
20mm BSP Male Inlet
www.marleypipesystems.co.za
LATCO PRESSURE
REGULATING VALVES
PRO-FIT HOT & COLD WATER SYSTEM
Y o u r
V a l u e
P a r t n e r
Marley’s trusted polymer system for pressure
control in hot and cold water systems
10508
GEYSER
INSTALLATION
& INSPECTION
CHECKLIST
Pro-fit Pipe Lengths
Pro-fit Pipe Coils
Pressure Sleeves
Couplings
Reducing Couplings
PRP016006 - Pipe 16mm Length 6m
PRP020006 - Pipe 20mm Length 6m
PRP016050 - Pipe 16mm Coil 50m
PRP020050 - Pipe 20mm Coil 50m
PRFSL16 - Pressure Sleeve 16mm
PRFSL20 - Pressure Sleeve 20mm
PRFCP16 - Coupling Equal 16mm
PRFCP20 - Coupling Equal 20mm
PRFCPR2016 - Coupling Reducing
20mm-16mm
Elbows
 COMPONENTS
PRFEL16 - Elbow 90° 16mm
PRFEL20 - Elbow 90° 20mm
Equal Tees
PRFTE16 - Tee Equal 16mm
PRFTE20 - Tee Equal 20mm
Reducing Tees
Copper Tee
PRFTR161620 - 16mm-16mm-20mm
PRFTR202016 - 20mm-20mm-16mm
PRFTR201616 - 20mm-16mm-16mm
PRFTR201620 - 20mm-16mm-20mm
PRFTC161516 - Tee Copper
Adaptor 16mm - Cu 15 - 16mm
Male Branch Tee
PRFTM161216 - Tee Male Branch
16mm - 1/2"
Allcomponentsmustbe
installedaccordingto
SANS10254.
Checkthepressurerating
ofthegeysertomatchthe
pressureratingofthevalve.
 ACCESS
• Mustbeinstalledforsafeoperation
• Ensureeasyaccessforrepairsand
maintenance
• Useenoughunionsandcouplingstoallowfor
removalwithoutcuttingpipework
 SAFETY TRAY
• Allgeysersmustbeinstalledwithasafetytray
largeenoughtocapturedropsfromsurrounding
valvesandpipework
• Mustbefittedoveraload-bearingwalland slopedtowardstheoutlet
• Thehotwatercylindermuststandonsupports
• Ensureaminimum40mmoutlettodischarge excesswaterfromthetraytotheoutsideofthe
building
 LOCATION OF ISOLATING
VALVE
• Mustbeaheadofthepressurecontrolvalve
• Ifitisnotalreadypartofthesystem,there
shouldbeanisolatingvalveontheexterior
ofthebuilding
DONOTinstallanisolatingvalveonthe
samelineasthepressurereliefvalve
 CONNECTING PIPES
• Ensureleaktightjoints
• Pipesmustbefirmlyanchored
 POSITION OF PRESSURE
CONTROL VALVE
• 100kPAvalvesmustbepositionedcloseto thegeyser(notmorethan2mbelow
thecylinder)
• Ensureabalancedpressuretoallshowers andmixers
• Pressurecontrolvalvemustbeaccessible sothatitcanbeservicedwithoutdrainingall thewater
 VACUUM BREAKERS
• Mustbefittedonhotsupplyandcoldsupply (expansionreliefvalveincludesvacuum
breakerfunction)
• Shouldbefittedon300mmrisersonthehot outletpipe(ifcloserthan700mmfromthe
outlet)
• Onacoldpipe,mustbeinstalledonan anti-syphonloop
 DISCHARGE PIPE FROM
VALVES
•
•
•
•
•
•
•
•
•
Nowatertraps
DischargepipesmustNEVERjointogether
Pipesmustbethesamediameterasthevalve
outlet
Pipesmustbeinclineddownwardsfrom
temperatureandpressuresafetyvalves
Metallicpipesmayonlybeusedfrom temperatureandpressuresafetyvalves
Ensurethatpipesdischargewhereitwillcause
nonuisancebutalsosothatthedischargeis visible
Dischargedoverflowmustbedirectedoutside
Maximumlengthfora20mmpipeis4mandfor
28mmpipe,9m
Amaximumof3bendsispermitted
 TESTING
Male Connectors
Female Connectors
Extensions
PRFCM1612 - Connector Male 16-1/2"
PRFCM1634 - Connector Male 16-3/4"
PRFCM2012 - Connector Male 20-1/2"
PRFCM2034 - Connector Male 20-3/4"
PRFCF1612 - Connector Female 16-1/2"
PRFCF1634 - Connector Female 16-3/4"
PRFCF2012 - Connector Female 20-1/2"
PRFCF2034 - Connector Female 20-3/4"
PRFEX1225 - Extension 1/2" - 25mm
PRFEX1220 - Extension 1/2" - 20mm
PRFEX1215 - Extension 1/2" - 15mm
PRFEX1210 - Extension 1/2" - 10mm
Double Entry Wall Outlet
Straight Copper
Adaptor/Connector
PRFOD90 - Double Entry Wall Outlet
- 90° 16mmx1/2”
PRFODPL - Double Entry Wall Outlet
- Parallel 16mmx1/2”
PRFCC1615 - Copper Adaptor 1
6mm - Cu 15
PRFCC2022 - Copper Connector
20mm - Cu 22
End Plugs
PRFPL16 - End Plug 16mm
PRFPL20 - End Plug 20mm
Elbow Connector
Adaptor
Female Elbow
PRFEF1612 - Elbow 90° Female
16mm - 1/2"
PRFEC1615 -Elbow 90° Copper
Adaptor 16mm - Cu 15
Wall Outlets
PRFOS1612 - Wall Outlet 16mm - 1/2"
PRFOS2034 - Wall Outlet 20mm - 3/4"
Male Elbow
PRFEM1612 - Elbow 90°
Male 16mm - 1/2"
• Allinstallationsmustbeflushed,inspectedand
testedforleakspriortohandover
 TEMPERATURE AND
PRESSURE SAFETY VALVE
• Mustbecorrectlyfittedintothehotwatercylinder
Itpreventsthenormalfunctioningofapressurerelief
valvetoreleaseexcesspressure
- 17 -
www.marleypipesystems.co.za
www.marleypipesystems.co.za
www.marleypipesystems.co.za
17
TRAINING
Empowering the industry towards better
product installations
Marley is a company that prides itself on nothing but quality – not only in
the products that we manufacture, but also the very integrity of the product
installations that make up the backbone of every building in South Africa,
from a freestanding house to a multi-storey high rise.
As part of our commitment to sustainable development at all levels of the
value chain, we strive to create opportunities for skills development. Not
only do we offer on-site and classroom training led by industry experts to
support plumbers and installers, but we also aim to provide knowledgeable
technical training at school and FET level to empower the plumbers and
installers of tomorrow.
The price of success
is hard work,
dedication to the
job at hand, and the
determination that
whether we win or
lose, we have applied
the best of ourselves
to the task at hand.
- Vince Lombardi
18
www.marleypipesystems.co.za
CONTACT US
Branch Offices
Bloemfontein: +27 51 434 2331/5
Cape Town: +27 21 045 0050
Durban: +27 31 791 5800
East London: +27 43 726 6505
George: +27 44 874 1160
Jet Park (MEGAFLEX): +27 11 823 1160
Namibia: +264 81 237 200
Nelspruit: +27 13 753 2571
Polokwane: +27 15 292 4141
Port Elizabeth: +27 41 045 0998
Zimbabwe +263 772 229 940
Agents:
Contract Supplies (Botswana): +267 392 2922
Enquire Here
Building
Head Office
1 Bickley Road,
Pretoriusstad, Nigel
Tel: +27 11 739-8600
Fax: +27 11 739-8680
Mining and Industrial
Head Office
1 Piet Pretorius Street,
Rosslyn, Pretoria
Tel: 0861 MARLEY
Tel: +27 12 045-0997
www.marleypipesystems.co.za