SW3-PLUS Water Filtration System Instruction - Coca

3M™ Water Filtration Products
SW3-PLUS Water Filtration
System Instruction Manual
Part Number 56170-01
The CUNO SW3-PLUS water filtration system is designed to helps reduce coarse and fine particulate matter from the incoming potable water supply. The system is rated for cyst reduction under NSF/ANSI Standard 53 with the applicable replacement cartridges.
The SW3-PLUS is also rated for chloramine and chlorine taste and odor reduction under NSF/ANSI Standard 42 with the applicable
replacement cartridges. These contaminants are reduced in the water so as not to adversely affect the taste of carbonated and
non-carbonated beverages. The SW3-PLUS also contains a built-in scale inhibitor*.
v
Installer: Please leave this manual with owner/operator.
Homeowner: Please retain for operation and future maintenance instructions.
1
3M™ Water Filtration Products
Table of Contents
Safety Information........................................................................................................................................ 2
Warning Statements..................................................................................................................................... 2
Caution/Important Notes............................................................................................................................... 3
Product Dimensions..................................................................................................................................... 3
How to Use “Push-in” Connectors................................................................................................................. 4
How to Use “Inlet/Outlet” Fittings.................................................................................................................. 4
Equipment Installation...............................................................................................................................4-5
Equipment Start-up Procedure . ................................................................................................................... 5
Cartridge Change-out Procedure................................................................................................................5-6
Troubleshooting............................................................................................................................................ 6
Parts Listing................................................................................................................................................. 7
Warranty....................................................................................................................................................... 8
SAFETY INFORMATION
Read, understand, and follow all safety information contained in these instructions prior to sanitization of the SGLP2-DUAL Reverse
Osmosis Filtration System. Retain these instructions for future reference.
Intended Use:
The SW3-PLUS Water Filtration System is intended for use in filtering potable water in the foodservice industry and has not been evaluated
for other uses. These systems are typically installed at the point-of-entry, and must be installed as specified in the installation instructions.
EXPLANATION OF SIGNAL WORD CONSEQUENCES
WARNING
Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury and/or property
damage.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury and/or property
damage.
CAUTION
Indicates a potentially hazardous situation, which, if not avoided, may result in property damage.
WARNING
To reduce the risk associated with choking:
• Do not allow children under 3 years of age to have access to small parts during the installation of this product.
To reduce the risk associated with the ingestion of contaminants:
• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or
after the system.
To reduce the risk associated with hazardous voltage due to an installer drilling through existing electric wiring or
water pipes in the area of installation:
• Do not install near electric wiring or piping which may be in path of a drilling tool when selecting the position to
mount the filter bracket.
To reduce the risk of physical injury:
• Depressurize system as shown in manual prior to cartridge removal.
To reduce the risk associated with back strain:
• Follow safe lifting procedures.
2
CAUTION
To reduce the risk associated with property damage due to water leakage:
• Read and follow Use Instructions before installation and use of this system.
• Installation and Use MUST comply with all state and local plumbing codes.
• Protect from freezing, remove filter cartridge when temperatures are expected to drop below 40°F (4.4°C);
• Do not install on hot water supply lines. The maximum operating water temperature of this filter system is 100°F (37.8°C).
• Do not install if water pressure exceeds 125 psi (862 kPa). If your water pressure exceeds 80 psi (552 kPa), you must install a pressure
limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure.
• Do not install where water hammer conditions may occur. If water hammer conditions exist, you must install a water hammer arrester.
Contact a plumbing professional if you are uncertain how to check for this condition.
• Do not use a torch or other high temperature sources near filter system, cartridges, plastic fittings or plastic plumbing.
• On plastic fittings, never use pipe sealant or pipe dope. Use PTFE thread tape only, pipe dope properties may deteriorate plastic.
• Take care when using pliers or pipe wrenches to tighten plastic fittings, as damage may occur if overtightening occurs.
• Do not install in direct sunlight or outdoors.
• Do not install near water pipes which will be in path of a drilling tool when selecting the position to mount the bracket.
• Mount filter in such a position as to prevent it from being struck by other items used in the area of installation.
• Ensure that the location and fasteners will support the weight of the system when installed.
• Ensure all tubing and fittings are secure and free of leaks.
• The disposable filter cartridge MUST be replaced every 12 months or at the rated capacity or if a noticeable reduction in flow rate occurs.
IMPORTANT NOTES
• Failure to follow instructions may void warranty.
• Allow a minimum of 3” (7.6 cm) clear space under filter to facilitate cartridge change.
• Install with the inlet and outlet ports as labeled. Make sure not to reverse connections.
• Some local codes may require the use of a licensed plumber or certified installer when disrupting a potable water line.
Product Dimensions
3
How to Use “Push-in” Connectors
This product is outfitted with user friendly ‘Push In’ connectors. Proper use of the connectors is shown in Figure 3. It is most important
that the tubing selected for use with these connectors be of high quality, exact size and roundness, and with no surface nicks or scratches.
If it is necessary to cut the tubing, use a plastic tubing cutter or sharp razor knife. Make a clean square cut. Should a leak occur at a
"Push-In" connector, the cause is usually defective tubing.
To Fix:
1. Relieve pressure
4. Reattach tubing
2. Release tubing 3. Cut off at least 1/4” from end 5. Confirm connection is leak free
How to Use the Inlet/Outlet Fitting
This product is outfitted with inlet/outlet fittings. The fittings can be attached or removed from the system without tools.
Retention clips are semi-circular in shape with three internal tabs, bottom, center and top. Tab intertaces with windows in the manifold
head near each connection port. clip is flexable and easily assembled following these instruction and illustrations.
1. Insert fitting into manifold.
2. With fitting inserted into manifold port, snap clip into place beginning at the bottom window
3. Push center tab into center window.
4. Finally push top tab into top window.
Step 1
Step 2
Step 3
Step 4
Equipment Installation
CAUTION
To reduce the risk associated with property damage due to water leakage:
• Read and follow Use Instructions before installation and use of this system.
• Installation and Use MUST comply with all state and local plumbing codes.
• Protect from freezing, remove filter cartridge when temperatures are expected to drop below 40°F (4.4°C);
• Do not install on hot water supply lines. The maximum operating water temperature of this filter system is 100°F (37.8°C).
• Do not install if water pressure exceeds 100 psi (689 kPa). If your water pressure exceeds 80 psi (552 kPa), you must install a pressure
limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure.
• Do not install where water hammer conditions may occur. If water hammer conditions exist, you must install a water hammer arrester.
Contact a plumbing professional if you are uncertain how to check for this condition.
• Do not use a torch or other high temperature sources near filter system, cartridges, plastic fittings or plastic plumbing.
• On plastic fittings, never use pipe sealant or pipe dope. Use PTFE thread tape only, pipe dope properties may deteriorate plastic.
• Take care when using pliers or pipe wrenches to tighten plastic fittings, as damage may occur if overtightening occurs.
• Do not install in direct sunlight or outdoors.
• Do not install near water pipes which will be in path of a drilling tool when selecting the position to mount the bracket.
• Mount filter in such a position as to prevent it from being struck by other items used in the area of installation.
• Ensure that the location and fasteners will support the weight of the system when installed.
• Ensure all tubing and fittings are secure and free of leaks.
• The disposable filter cartridge MUST be replaced every 12 months or at the rated capacity or if a noticeable reduction in flow rate occurs.
4
IMPORTANT NOTES
• Failure to follow instructions may void warranty.
• Allow a minimum of 3” (7.6 cm) clear space under filter to facilitate cartridge change.
• Install with the inlet and outlet ports as labeled. Make sure not to reverse connections.
• Some local codes may require the use of a licensed plumber or certified installer when disrupting a potable water line.
The SW3-PLUS system may be used with metal or non-metallic piping systems.
WARNING: Any non-metallic fittings used in the installation must be of adequate rating for the line pressure.
1. Shut off incoming cold water supply.
2. Mount filter system to a wall or support structure using the mounting holes provided on the metal bracket.
3. Connect cold water line to the 1/2” hose barb connection on the inlet fitting assembly;
CAUTION: Ensure shut-off valve on the inlet fitting assembly is in the “OFF” position
4. Connect post-mix line to the 1/2” hose barb connection on the post-mix outlet fitting assembly.
5. Connect the ice maker line to the 3/8” flare connection on the ice outlet fitting assembly; the ice outlet fitting assem-
bly is shipped with the flare connection capped, remove the cap before making plumbing connections.
6. Apply water or light coat of food grade lubricant to the o-rings on each of the three inlet/outlet fitting assemblies.
CAUTION: Do not use petrolium jelly.
7. Assemble each fitting assembly into the manifold ports as indicated in the drawing on this page.
8. Assemble clips to retain each inlet/outlet fitting assembly; refer to drawings on this page.
9. Apply water or a light coat of food grade lubricant to the o-ringson each of the cartridges.
CAUTION: Do not use petrolium jelly. Refer to the drawing on page 5. for proper cartridge location.
WARNING: The cartridges are not interchangable - forcing a cartridge into the incorrect location will cause damage.
10. Align the tabs of the cartridge with the slots in the reatining plate and insert the cartridge into manifold.
11. Turn the cartridge to the right until a click sound is heard. Repeat for all catridges; the clicking sound indicates the cartridge is properly engaged.
Equipment Start-up Procedure
1. Turn on incoming water to system.
2. Pressurize system by rotating the inlet valve handle on the manifold to the “ON” position.
3. Check for leaks.
4. Insert the plastic tubing provided into the flush valve to direct water to drain.
5. Open flush valve.
6. Flush system in accordance with performance data sheet.
7. Close flush valve. System is now ready for service.
Cartridge Change-out Procedure
CAUTION
To reduce the risk associated with property damage due to water leakage:
• Read and follow Use Instructions before installation and use of this system.
• Installation and Use MUST comply with all state and local plumbing codes.
• The disposable filter cartridge MUST be replaced every 12 months or at the rated capacity or if a noticeable reduction in flow rate occurs.
Cartridges will need to be changed every 12 months or when low pressure in indicated on the manifolds pressure gauge, whichever
occurs first. Depending on local water quality, you may need to change the cartridges prior to the 12 month recommended changeout. The loss of flow to carbonators or improper fill at the ice maker are also indicators that the cartridges will need to be replaced.
1. Rotate shut-off valve on manifold to the “OFF” position.
2. Install plastic tubing provided into flush valve on manifold and direct to drain.
3. Open vent valve to depressurize system
4. Push tab to release cartridge locking mechanism while simultaneously rotating cartridge slightly to the left
5. Using both hands and holding cartridge from the bottom, rotate the cartridge a quarter turn to the left and gently pull down. CAUTION: A small amount of water will drain from manifold as cartridge is removed.
5
6. Remove sanitary cap from new cartridge. Install cartridge with a quarter turn to the right until cartridge comes to a complete stop. NOTE: Cartridges are keyed to fit proper location only.
7. Slowly turn the valve on the manifold to the “ON” position and check for leaks.
8. Flush per the performance data sheet. System is now ready for use.
Step 1
Step 5
Step 2
Step 3
Step 6
Step 7
Troubleshooting
No water flow through system
Not enough water to post-mix
system
Short filter life
Inlet valve closed
Check shut-off valve position
Filters clogged
Replace cartridges
Low incoming water pressure
Check source
Filters clogged
Replace cartridges
Temporarily dirty water
Change cartridges or contact
maintenance
6
Parts Listing
Item
Part no.
Description
Qty
Micron Rating
Function
1
6224301
Manifold Assembly
(complete)
1
Routes water through system
2
60-2333700
Vent
1
Releases trapped air
3
56138-08
Cartridge Pack
SW-CFR
2
0.5
Chloramine, chorine taste and odor
SW-SR
1
0.5
Built-in scale inhibitor*
4
85005-50
Pressure Gauge
1
Monitors manifold outlet pressure
5
85-8528
Clip
6
Retains inlet/outlet fittings
6
63597320
O-ring
12
Seals inlet/outlet fittings
7
6225004
Plumbing Kit
1
Inlet/Outlet with o-rings and clips
8
56175-01
Key ring/lever Kit
3
Holds cartridge in place
*Built-in scale inhibitor tested by manufacturer.
5
6
4
7
1
7
7
8
2
3
3
3
7
Limited Warranty
CUNO Incorporated warrants this Product (excluding disposable filter cartridge(s)) to be free from defects in material and workmanship for five (5) years from the date of purchase. The disposable filter cartridge is warranted from defects in material and workmanship for a period of one (1) year from the date of purchase. This warranty does not cover failures resulting from abuse, misuse,
alteration or damage not caused by CUNO or failure to follow installation and use instructions. If the Product is defective CUNO will
replace the Product or refund your Product purchase price. CUNO will not be liable for any indirect, special, incidental, or consequential damages arising from the use of this Product. Some states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation may not apply to you. To obtain warranty service, mail your request to Warranty Claims, CUNO
Incorporated, 400 Research Parkway, Meriden, CT 06450. Proof of purchase (original sales receipt) must accompany the warranty
claim, along with a complete description of the Product, model number and alleged defect. This warranty gives you specific legal
rights and you may have other rights which vary from state to state, or country to country.
CUNO Incorporated,
a 3M Company
© 2008 3M Company. All rights reserved.
3M and CUNO are trademarks of 3M Company used under license.
INSTR4311 0508
8
400 Research Parkway
Meriden, CT 06450, USA
Toll Free: 1.888.218.CUNO
Worldwide: 203.237.5541
Fax: 203.238.8701
www.cunofoodservice.com