Natural Comfort for Everybody - Mitsubishi Electric Australia

Natural Comfort for Everybody
AIR CONDITIONING SYSTEMS
Comfort takes
on new
meaning with
the power of
technology
Our technologically advanced Mr. Slim
Power Inverter systems improve comfort,
operate with significantly less noise,
... and provide increased energy savings.
02
Contents
Product Line Up
4
Advanced Power Inverter
6
Cleaning-Free Pipe
Reuse Technology
8
Advanced Technology
for High Efficiency
9
Wi-Fi Controller
11
MA Wall Controller
12
Zone Controller
14
Product Series
16
Main Features
23
Specifications
26
03
Product Line-up
2.5kW
3.5kW
5.0kW
6.0kW
7.1kW
10.0kW
PLA-RP60BA
PLA-RP71BA
PLA-RP100BA
SLZ
Series
4-Way
Ceiling
Cassette
Compact
Cassette
SLZ-KA25VAQ(L)
SLZ-KA50VAQ(L)
PLA
Series
Wide
Power
Cassette
*Combination only
with SUZ-KA71
Compact
Bulkhead
SEZ
Series
SEZ-KD25VAQ(L)
SEZ-KD35VAQ(L)
SEZ-KD50VAQ(L)
SEZ-KD60VAQ(L)
SEZ-KD71VAQ(L)
PEAD
Series
PEAD-RP71JAAD
PEAD-RP100JAAD
CeilingConcealed
PEA
Series
PEA-RP100GAA
CeilingSuspended
PCA
Series
PCA-RP50KAQ
PCA-RP60KAQ
PCA-RP71KAQ
PCA-RP100KAQ
*Combination only
with PUHZ-RP71
WallMounted
PKA
Series
PKA-RP71KAL
PKA-RP100KAL
SUZ-KA71VAD
Outdoor
Unit
SUZ-KA25VAD
SUZ-KA35VAD
*SEZ/SLZ indoor units should be connected to an SUZ outdoor unit.
*PKA-RP71: only for PUHZ-RP outdoor connection.
*PEA-RP: No wireless remote controller as optional parts.
04
SUZ-KA50VAD
SUZ-KA60VAD
PUHZ-RP71VHA5
PUHZ-RP100V/YKA2
12.5kW
14.0kW
17.0kW
20.0kW
25.0kW
Remote Controller
optional for
SLZ-VAQ
optional for
SLZ-VAQ
See
Page
22
standard for SLZ-VAL
optional
16/17
optional for
SEZ-VAQ
22
optional
PLA-RP125BA
PLA-RP140BA
optional
optional for
SEZ-VAQ
standard for SEZ-VAL
optional
PEAD-RP125JAAD
PEAD-RP140JAAD
optional
optional
optional
optional
PEA-RP125GAA
PEA-RP140GAA
PEA-RP170WJA
PEA-RP200WJA
PEA-RP250WHA
optional
19
optional
20
optional
21
optional
optional
PCA-RP125KAQ
18
PCA-RP140KAQ
optional
optional
optional
PUHZ-RP125V/YKA2
PUHZ-RP140V/YKA2
PUHZ-RP170V/YKA2
PUHZ-RP200V/YKA2
PUHZ-RP250YKM
05
Advanced Power Inverter
Mitsubishi Electric’s Power Inverter Systems
Increase Energy Efficiency
Demand Function
Select the model to best match your needs from our expanded
model range.
The units with service reference number PUHZ-RP·VHA5R1-A and
PUHZ-RP·V/YKA2R1-A are demand response capable. This capability
is possible with the connection of a demand response enabling device
(DRED) to the terminal block interface (BT00C023G02).
Based on the connection of a demand response enabling device (DRED)
to the outdoor unit, Demand Response Mode is activated in response to
signals sent from the electric authority at times when it is necessary to
reduce peak demand.
To better meet the needs of shops and offices, our outdoor units
are offered in three-phase power supply models in addition to the
existing line-up of single-phase models.
This item is supplied in a sealed bag located in the compressor chamber.
Connection of the terminal block interface is a mandatory requirement for
the installation of any PUHZ-RP·VHA5R1-A and PUHZ-RP·V/YKA2R1-A
units. When installed, the system is demand response capable; that is,
ready to be connected to a demand response enabling device (DRED)*.
*PUHZ-RP250 is excluded.
Please contact Mitsubishi Electric Australia Pty. Ltd. for details.
Air Conditioner Demand Response Mode
Demand Response
Mode (DRM)
PUHZ-RP71
PUHZ-RP100/125/140/170/200
DRM1
Description of Operation in this Mode
Compressor Off
The air conditioner continues to cool or heat
during the demand response event, but the
DRM2
electrical energy consumed by the air conditioner
in a half hour period is not more than 50% of the
total electrical energy that would be consumed if
operating at the rated capacity in a half hour period.
The air conditioner continues to cool or heat
during the demand response event, but the
DRM3
electrical energy consumed by the air conditioner
in a half hour period is not more than 75% of the
total electrical energy that would be consumed if
operating at the rated capacity in a half hour period.
PUHZ-RP250
Outdoor Line-up (PUHZ-RP Series)
Single-Phase
Three-Phase
71
100
125
140
170
•
•
•
•
•
•
•
•
•
200
250
•
•
Outdoor Unit
DRM1 DRM2 DRM3
Terminal Block
06
C
Demand
Controller
High Energy Efficiency
Wider Performance Range
Comparison of EER (Cooling Mode)
Comparison of EER between Non-Inverter and Power Inverter
(4-way Ceiling Cassette) models.
Operation is now possible at lower speeds thus cutting energy
Wider Performance
Range
losses
produced by
the repeated On/Off operation of
Operation is now
possible
at lower
thus
cutting
energy
losses
Non-Inverter
models.
Comfort
isspeeds,
improved
while
power
consumption
produced by the repeated On/Off operation of non-inverter models.
is reduced.
Comfort is improved while power consumption is reduced.
Average
UP
4.00
4.0
71 class 3.3-8.1 kW
100 class 4.9-11.4 kW
80%
UP
3.5
125 class 5.5-14.0 kW
3.40
57%
UP
3.0
3.29
3.27
41%
32%
UP
140 class 6.2-15.3 kW
0
2
4
6
8
10
12
14
16
18kW
UP
Heating capacity ranges
2.5
4-way ceiling cassette
71 class 3.5-10.2 kW
2.47
2.33
100 class 4.5-14.0 kW
2.22
2.17
4-way ceiling cassette
Cooling capacity ranges
53%
EER
125 class 5.0-16.0 kW
2.0
Outdoor Unit
71 class
Power Inverter Model
100 class
125 class
140 class 5.7-18.0 kW
140 class
0
Non-inverter Model
*EER are measured at rated condition.
2
4
6
8
10
12
14
16
18kW
Long Maximum Piping Length
The maximum piping length is 75m. Therefore there is a wide range of
layout possibilities for unit installation.
High Power
More power for faster cooling/heating.
Max. Piping Length
Powerful Cooling/Heating Performance
The maximum operating cooling/heating capacity of the Mr. Slim
Power Inverter units have been improved (compared to conventional
Non-Inverter models) when operating in either low or high outdoor
temperatures.
PUHZ-RP71
PUHZ-RP
Cooling Capacity (kW)
R22
Non-Inverter
100/125/140/170/200/250
4-Way Ceiling Cassette
7.7
8.1
105%
100 Class
9.7
11.4
118%
125 Class
12.4
14.0
113%
140 Class
14.0
15.3
109%
R22
Non-Inverter
Max. Piping Length
(One-Way)
30m
50m
30m
75m
R401A
Power Inverter Max. (PUHZ-RP)
71 Class
Heating Capacity (kW)
Max. Height
Difference
4-Way Ceiling Cassette
R401A
Power inverter Max. (PUHZ-RP)
71 Class
8.4
10.2
121%
100 Class
10.4
14.0
135%
125 Class
14.0
16.0
114%
140 Class
16.1
18.0
112%
07
Cleaning-Free* Pipe
Reuse Technology
PUHZ-RP71-200
Ability to Use Existing Piping Reduces Pipe Waste and Replacement Time
No need to clean* at the time of system renewal.
Chloride residue builds up in existing pipes and becomes a source of trouble. In addition, the iron particles and slime produced as a result
of compressor failure lead to problems. To counter this, various original Mitsubishi Electric technologies have been combined to enable the
introduction of “cleaning-free pipe reuse”.
This feature is available in the PUHZ-RP71-200.
Why Can’t Existing Piping Be Used?
1
R22 Refrigerant
2
Problem
At time of renewal
At time of
compressor failure
Chloride residue
Increased chloride
residue
R410A Refrigerant
Problem
Result
High heat generated
during operation
Accelerated deterioration
of refrigerant oil
Refrigerant circuit
malfunctions and
causes failure
Iron particles and slime
Cleaning pipe or replacing with new pipe is required
Cleaning pipe or replacing with new pipe is required
Mitsubishi Electric’s Original Replacement Technologies
Countermeasure for Problem 1
Countermeasure for Problem 2
Technology 1:
Original High-Quality Filtration
Technology 2:
Friction Reduction (moving parts in compressor)
Our original high-quality filtration device called the “Wide Strainer”
is equipped inside the refrigerant inlet and outlet pipe. The “Wide
Strainer” traps iron particles and provides cleaning-free pipe reuse.
In addition, improvements to the metal used in the bearings of our
new scroll compressors provide more robust units.
Friction inside the compressor is reduced by using an original
Mitsubishi Electric technology called the “Heat Caulking Fixing
Method” or coating the edge of the blade in the scroll compressor,
thereby suppressing the increase in temperature that causes
refrigerant oil deterioration.
n
ation device
uipped inside
et pipe. The
articles and
reuse. In
metal used in
compressors
Wide strainer”
Strainer
“Wide
Existing piping can be used without cleaning*
 Cautions when using existing piping
• When removing an old air conditioning unit, please make sure to perform the pump-down process and recover the refrigerant and refrigerant oil.
• Check to ensure that the piping diameter and thickness match Mitsubishi Electric specifications.
• Check to ensure that the flare is compatible with R410A.
*Cleaning-Free Pipe Reuse Technology specifically applies to piping which is contaminated with chlorine residue, iron particles and slime. These contaminants
are typically found in piping in which the previous system utilised R22 refrigerant. Cleaning-Free Pipe Reuse Technology cannot be used to clean pipes which
contain foreign matter other than what can be generated from an operating air conditioner.
08
Advanced Technology
for High Efficiency
Highly Efficient Fan and Grille for Outdoor Unit
Highly Efficient Heat Exchanger
The shape of the fan and the grille in the outdoor unit has been
redesigned to increase the airflow and to make the heat exchange
process more efficient while maintaining the same operating
noise level.
A high density and increase in surface area have improved the
heat-exchange efficiency of the heat exchanger.
Outdoor Unit Fan Opening Increased
PUHZ-RP100-200
The pipe diameter has been changed from 9.52 to 7.94mm, resulting in a
high-density heat exchanger.
The diameter of the opening for the fan in the outdoor unit has
been increased from 490 to 550mm. Airflow has been increased
while maintaining the same fan rotation speed.
High-Density Heat Exchanger
PUHZ-RP100-200
2 lines, 52 columns
2 lines, 64 columns
(RP100-200)
Opening increased
from 490 to 550mm
in diameter
Heat-Exchange Surface Area Increased
PUHZ–RP100–200
The heat exchanger size has been extended horizontally, hence increasing
the surface area.
Increase in Heat Exchanger surface area
Grille Shape Changed
PUHZ-RP71-200
The shape of the air outlet grille has been changed to
reduce pressure loss. This has helped to improve heat exchange
performance.
Heat Exchanger
Heat Exchanger
PUHZ-RP•HA
PUHZ-RP•KA
Heat Interchanger (HIC) Added <PUHZ-RP140>
A HIC circuit has been added to improve energy efficiency during
Heat Interchanger (HIC) Added
cooling
operation. Liquid refrigerant is rerouted, transformed into a
PUHZ-RP140
(HIC) Added <P
HeattoInterchanger
gas Added
state <PUHZ-RP140>
and injected back into the system
increase overall
Heat Interchanger (HIC)
A HIC circuit has been added to improve energy efficiency during cooling
HIC circuit has thereby
been added to imp
the refrigerant
beingduring
sent to theA compressor,
A HIC circuit has beenpressure
added to of
improve
energy efficiency
operation. Liquid refrigerant is rerouted, transformed
into a operation.
gas state Liquid refrigerant is
cooling
cooling operation. Liquid
refrigerant
rerouted,
transformed into and
a
reducing
theisload
on the
raising
efficiency.
and injected
back into
the compressor
system to increase the
overall
pressure of the
gas state and injected back into th
gas state and injected back into the system to increase overall
refrigerant being sent to the compressor, thereby reducing
on the
pressurethe
of load
the refrigerant
being sen
pressure of the refrigerant being sent to the compressor, thereby
compressor and increasing efficiency.
reducing
the
load
on the compressor a
reducing the load on the compressor and raising efficiency.
PUHZ-RP•HA
PUHZ-RP•KA
Cooling Operation
Indoor
HEX
Inflexed Fan
PUHZ-RP100-200
Integrating a fan with improved ventilation characteristics and
a newly designed rear edge that suppresses wind turbulence
increases fan operation efficiency.
A
Compressor
Power
Receiver
Outdoor
HEX
LEV B
Heat
Interchanger
(HIC)
LEV A
A
LEV C
Heat Interchanger
(HIC)
w/ HIC circuit
w/o HIC circuit
Increasing the pressure of the refrigerant
sent to the compressor reduces the
compression load.
Fan rear edge
see specification on Page 24
see specification on Page 24
09
Advanced Technology
for High Efficiency
Numerous leading-edge technologies assure high efficiency.
Reluctance DC Rotary Compressor
DC Fan Motor
The reluctance DC motor has a rotor equipped with powerful
neodymium magnets. The magnetic torque produced by the neodymium
magnets and reluctance torque results in more efficient operation.
A highly efficient DC motor has been installed to drive the fan
of outdoor units, realising up to 60% higher efficiency when
compared to an equivalent AC motor.
PUHZ-RP71
PUHZ-RP71–200
Vector-Wave Eco Inverter
DC compressor
motor (rotor)
Neodymium
magnets
This inverter monitors the varying compressor motor frequency and
creates the most efficient waveform for the motor speed. As a result,
operating efficiency in all speed ranges is improved, less power is used
and energy consumption is reduced.
Smooth AC Wave Pattern
Magnetic torque
+
Reluctance torque
Smooth wave pattern
Highly Efficient DC Scroll Compressor
The inverter size has been reduced using insert-molding, where the
circuit pattern is molded into the synthetic resin. To ensure quiet
operation, soft PWM control is used to prevent the metallic whine
associated with conventional inverters.
Sine-wave drive soft PWM
Inverter size has been reduced using insertmolding, where the circuit pattern is molded into
Higher efficiency has beenthe
achieved
by resin. To ensure quiet operation,
synthetic
soft
PWM control
is used to prevent the metallic
adding a frame compliance
mechanism
to the
associated
with conventional inverters.
DC scroll compressor. Thewhine
mechanism
allows
PUHZ-RP100–200
movement in the axial direction of the frame
supporting the cradle scroll, thereby greatly
reducing the leakage and friction loss, and
ensuring higher efficiency at all speeds.
Fixed scroll
Frame can
move in direction
of axis
Power Receiver and Twin LEV Control
PUHZ-RP71–200
Leakage loss (minimum)
Thrust gas power (minimum)
Thrust friction loss (minimum)
Secondary back-pressure chamber
minimises thrust friction loss
Substantial
reduction in leakage
and friction loss
Primary back-chamber minimises
leakage loss
Frame
10
Cradle scroll
Mitsubishi Electric has developed a power receiver and twin linear
expansion valves (LEVs) that optimise the performance of the
compressor. By ensuring optimum control in response to the operating
waveform and outdoor temperature, this technology is tailored to the
characteristics of the new refrigerant to enhance operating efficiency.
Wi-Fi Controller
MAC-559IF-E
Wi-Fi Control unlocks the door to smarter heating or cooling, for
total home comfort wherever you are. This innovative technology
connects your domestic high wall, floor mounted and ducted air
conditioner to your smartphone, tablet or online account, giving
you the freedom to fully control each unit on-the-go via an Internet
connection from anywhere in the world.
Available for Download
Download the Wi-Fi app from the App Store or Google Play.
Superior Customisation
Develop Operating Rules
Room Temperature Limits
Control Multiple Units
This innovative technology places multiple functions of your
air-conditioner at your fingertips. Turning the unit on/off,
adjusting set temperature, changing mode, fan speed and
airflow direction are all possible.
With the ability to sense the room temperature and
automatically turn the unit On/Off, it takes the room
to the desired temperature, creating ultimate comfort
for your home. In winter set minimum temperatures
to warm up your home and in summer set maximum
temperatures to create comfort, cooling the room.
Tailor your system to always meet your needs. Unlock the
full potential of your air-conditioner, program your system to
automatically turn on/off at specific times, change settings,
and develop temperature rules to ensure superior comfort
day after day.
Customise the settings of each air-conditioner in your
home. Purchase multiple adaptors to manage all
air-conditioners independently on the same account
to ensure complete control over your system.
The result is a system tailored to your needs.
Minimum Requirements
Wi-Fi FEATURES
• A compatible WPS router with WPA2-AES encryption, with coverage including
the air conditioner's installation location.
» View and control from anywhere in the world
You will require:
• A PC/Tablet/Smartphone that is iOS, Android compatible.
• A MAC-559IF-E adapter per indoor unit.
• Compatible Mitsubishi Electric air-conditioner.
» Enhance energy savings
» Set up 7 day weekly schedule
» Wireless connection using WPS
For a full list of requirements visit mitsubishielectric.com.au/wifi
11
MA Wall Controller
PAR-33MAA-J
Easier to read thanks to use of a Full Dot Liquid-Crystal Display with backlight, and easier to
use with a menu format that has reduced the number of operating buttons.
Multi-Language Display
Night Setback
Control panel operation in eight different languages.
Choose the desired language, among the following:
English
Spanish
Italian
Keep desired room temperatures automatically
This function monitors the room temperature and automatically activates
the heating mode when the temperature drops below the preset minimal
temperature setting. It has the same function for cooling, automatically
activating the cooling mode when the temperature rises above the
preset maximum temperature setting.
German
Temperature Range Restriction
Prevents Overcooling/Overheating
French
Russian
Portuguese
Using a temperature that is 1°C lower/higher for cooling/heating
results in a 10% reduction in power consumption.* Temperature Range
Using a temperature
that is 1°Cand
lower/higher
heating/cooling
Restriction
limits the maximum
minimumfor
temperature
settings,
results in a 10% reduction in power consumption.* Temperature
contributing
to
the
prevention
of
overcooling/overheating.
Range Restriction limits the maximum and minimum temperature
Swedish
Display Example (Operation Mode)
Full Dot LCD
settings, contributing to the prevention of overheating/overcooling.
*Based on Mitsubishi Electric laboratory tests in controlled conditions
*Based on Mitsubishi Electric laboratory tests in controlled conditions
(Setting example of minimum temp. in 25˚C)
Cooling/Dry
19˚C
30˚C
Possible temperature range setting
25˚C
PAR-33MAA-J
Energy Efficiency Schedule
Lower temperatures cannot
be selected
To prevent excessive cooling
Recommended for:
Precise control of power consumption
PUHZ-RP71-200
Offices and Restaurants
The amount of power consumed in each time period is managed so that
the demand value is not exceeded. The demand control function can
be set to start and finish in 5-minute units. Additionally, the level can be
adjusted to 0, 50, 60, 70, 80 or 90% of maximum capacity, and up to 4
patterns can be set per day. Air conditioning operation is automatically
controlled to ensure that electricity in excess of the contracted volume is
not consumed.
Setting pattern example
Auto-Return
Prevents wasteful operation by automatically returning to the
preset temperature after specified operating time
After adjusting the temperature for initial cooling on a hot summer day
or heating in winter, it is easy to forget to return the temperature setting
to its original value. The Auto-Return function automatically resets the
temperature back to the original setting after a specified period of time,
thereby preventing overcooling/overheating.
The Auto-Return activation time can be set in 10-minute units,
in a range between 30 and 120 minutes.
Start time
Finish time
Adjusted capacity level
8:15
12:00
80%
12:00
13:00
50%
13:00
17:00
90%
Auto-Off Timer
17:00
21:00
50%
Turns cooling/heating off automatically after preset time elapse
Operation Lock
Fixed temperature setting promotes energy efficiency
In addition to operation start/stop, the operation mode, temperature
setting and airflow direction can be locked. Unwanted adjustment of
temperature settings is prevented and an appropriate temperature is
constantly maintained, leading to energy efficiency. This feature is also
useful in preventing erroneous operation or tampering.
Recommended for:
Offices, Schools, Public Halls, Hospitals, Computer Server Facilities
12
30˚C
Lower temperature limit
*Auto-Return cannot be used when Temperature Range Restrictions is in use.
When using Auto-Off Timer, even if one forgets to turn off the unit,
operation stops automatically after the preset time elapses, thereby
preventing wasteful operation. Auto-Off Timer can be set in 10-minute
units, in a range between 30 minutes and 4 hours, eliminating all anxiety
about forgetting to turn off the unit.
Recommended for:
Meeting Rooms and Changing Rooms
Weekly Timer
Setting Example (Restaurant in summer time)
Set up to 8 patterns per day including temperature control
*Weekly Timer cannot be used when on/off Timer is in use.
Temperature setting (°C)
The Weekly Timer enables the setting of operation start and finish
times and adjusting the temperature as standard features. Up to
8 patterns per day can be set, providing operation that matches
the varying conditions of each period, such as the number of
customers in the store.
26
Preparation
1
Busy
hours
Off-peak Set to higher temperature
hours
Set to lower temperature
7
25
Opening
time
2
24
4
Lunch time
Dinner time
5
8-pattern setting
22
0
Closing time
6
3
23
8
10
12
14
16
18
20
22
Necessary to change temperature settings for cooling/heating times.
*Joint research conducted by Mitsubishi Electric.
24 (Time)
Rotation, Back-up and 2nd Stage Cut-in Functions (PAR-33MAA-J)
PUHZ-RP71–200
Operation Pattern
(1) Rotation and Back-up Functions
Function Outline
(Back-up Function Only)
• Main and Sub units take turns operating according to a rotation
interval setting.
• If one unit malfunctions, the other unit automatically begins
operation (Back-up Function).
System Image
System Image
O/U-1
O/U-2
Main
unit
R/C
Main
unit
I/U-1
Run
Sub
unit
I/U-2
Stop
Abnormal condition
Run
(Rotation Function) & (Back-up Function)
Sub
unit
I/U-1
Error occurs on main unit.
Main
Sub
Start operation
Start operation
I/U-2
O/U : Outdoor Unit
I/U : Indoor Unit
R/C : Wired Remote Controller
Main
Sub
Sub
Error occurs on main unit.
Main
Sub
Main
Main
unit
I/U-1
Run
Stop
Run
Abnormal condition
Sub
unit
I/U-2
Stop
Run
Stop
Run
1–28 days
1–28 days
(When
therequest
request
code
"313",
each
operates
alternatively
in daily cycle)
(When the
code
is “313”,
each
unit unit
operates
alternately
in daily cycle.)
(2) 2nd Stage Cut-in Function
(2) 2nd Stage Cut-in Function
Function Outline
Function Outline
• Number of units operating is based on room tem• Number of unitsperature
operating
is predetermined
based on roomsettings.
temperature
and
• When
room temperature rises above the desired
and predetermined
settings.
setting, the standby unit starts (2-unit operation).
• When room temperature rises above the desired setting,
• When the room temperature falls 4°C below the prethe standby unit starts (2-unit operation).
determined setting, the standby unit stops (1-unit
• When the room operation).
temperature falls 4°C below the
predeterminedSystem
setting,
the standby unit stops (1-unit
Constraint
operation). • This function is only available for rotation operation
and when the back-up function is in cooling mode.
System Constraint
Operation Pattern (When Cooling)
2nd Stage Cut-in Function
Room temp. >
= Set point
Sub unit starts operation
Start operation
Main
unit
I/U-1
Run
Sub
unit
I/U-2
Stop
Room temp. >
= Set point –4°C
Sub unit stops
Run
Stop
• This function is only available for rotation operation and when
the back-up function is in cooling mode.
Easy Maintenance Function
PUHZ-RP71–200
• Nearly maintenance-free operation.
• Monitor operation data of the indoor and outdoor units via the remote controller.
Remote controller also lets you set the operating frequency, allowing easier inspection.
Compressor
Outdoor Unit
Indoor Unit
1. Accumulated operating time (×10hr)
4. Heat exchanger temperature (°C)
7. Intake-air temperature (°C)
2. Number of on/off times (×100 times)
5. Discharge temperature (°C)
8. Heat exchanger temperature (°C)
3. Operating current (A)
6. Outdoor-air temperature (°C)
9. Filter operating time* (hr)
*The filter operating time is the time elapsed since the filter button was reset.
13
Zone Controller
PAC-ZC40/80L-E, PAC-ZC40/80H-E
Operation of up to 8 dampers. Occupancy and brightness sensors provide greater comfort while
improving energy-saving performance.
Control Operation of up to 8 Dampers
By controlling the operation of up to eight dampers, excessive power consumption to condition unoccupied areas and areas where air conditioning
is not needed can be prevented. Detailed control makes it possible to set operation to suit the user’s needs.
Oven
WIP
Living
Kitchen
PEAD/
PEA
Veranda
Media
Dining
Oven
WIP
Air
Intake
Air
Outlet
Bed 4
Robe
WR
Robe
Robe
Living
Kitchen
PEAD/
PEA
Media
Entry
Porch
Master suite
Veranda
Home theater
Bed 2
Bed 3
Dining
LED Indicator
The LED indicator in the lower part of the controller clearly shows
The LED indicator in the lower part of the controller clearly shows the operation mode. Easily confirm if the air conditioning is On or Off
the operation mode. Easily confirm if the air conditioning is on or off
from
a distance.
Bed 4
Robe
from a distance.
*Set to all green display before shipping.
*Set to all green display before shipping.
Robe
Brightness
sensor: If room light is on, energy-saving control is deactivated.
Robe
me theater
Bed 3
Bed 2
Occupancy Sensor: Judges whether or not someone is in the room by detecting human motion.
If the room is unoccupied, air conditioning is switched to energy-saving mode.
Touch panel with backlight: A 4.3-inch touch-panel liquid-crystal screen with a backlight has
been incorporated.
Temperature sensor: Monitors the temperature near the remote controller.
LED indicator: Indicates the operation mode or room temperature using colours.
*Setting is required.
Wi-Fi Compatibility
Schedule Setting
Can be operated from tablet, smartphone, etc.
Zone Controller
PAC-ZC 40H-E
240 Volt AC
4 zones (max.)
PAC-ZC 80H-E
240 Volt AC
8 zones (max.)
PAC-ZC 40L-E
24 Volt AC
4 zones (max.)
PAC-ZC 80L-E
24 Volt AC
8 zones (max.)
Optional Parts
14
Wi-Fi Control Interface
MAC-559IF-E
Remote Sensor
PAC-SE4ITS-E
Zone Remote Controller
PAR-ZC01M-E
• Built-in weekly schedule function can control turning the
air conditioner on and off, and opening and closing of each damper.
Up to eight patterns can be set for each week, enabling operation
suitable for each time zone to be set.
• Night setback function is incorporated. If the room temperature is
outside of the temperature range setting, heating or cooling operation
starts automatically. This can prevent condensation or excessive
temperature rise in the room.
Easy to See and Use
• A large, full-dot liquid-crystal screen is incorporated,
simplifying touch panel operation.
• The backlight makes operation in dark rooms possible.
Main Screen
Zone Control Screen
Actual size 120x140x25mm (HxWxD)
Occupancy and Brightness Sensors
Occupancy sensors equipped with the controller can detect
when you leave the room. By then automatically switching into
energy-saving mode the Zone Controller turns the air conditioner
off, leading to potential energy savings.
Brightness sensors detect when a room changes between and light,
The controller
is equipped
with mode
a occupancy
and brightness
sensors
and dark and
energy-saving
can be enabled
accordingly.
that are
to determine
if the room
nocan
one is
Dayused
and time
settings combined
with is
theoccupied.
brightness When
sensors
in theberoom,
operation
switches
toair
energy-saving
Excellent
used to
automatically
turn the
conditioner off mode.
when lights
are
for ensuring
switchedthat
off. the air conditioning gets turned off, and thereby
contributing to further energy savings.
When “Zone Control” mode is selected among the energy-saving mode settings
shown below.
The damper is closed.
Occupancy Sensor
PAR-ZC01M-E Remote Controller
10m
Wall
10m
PAR-ZC01M-E
Remote Controller
110˚
10m
11˚
20˚
110˚
31˚
Floor
Detection distance, right/left detection angle
Up/Down detection angle
Energy Saving Mode
Energy-Saving Mode settings can be selected (see table below)
Deactivate
Even if no one is detected, Energy Saving Mode is not set
Temperature
setting slide
The slide to set desired temperature from presently
set temperature
Reduce Airflow
Set airflow to "Low"
Operation/Stop
Stop operation
Zone control
Turn off target zone settings
15
PLA Series
4-WAY CEILING CASSETTE
Advancements in PLA series improve style and
performance for ensured indoor comfort
Auto Fan Speed Mode
The fan speed is adjusted automatically, thereby hel
comfortable room environment at all times. At the st
high fan speed provides quick heating/cooling of th
desired temperature is reached, the fan speed is r
heating/cooling and greater comfort.
Conventional model
Wide Airflow
Wide-angle outlets distribute airflow to all corners of the room, ensuring the room is sufficiently cooled/heated. Horizontal airflow and a
fan speed reduced by 20% compared to conventional models also contribute to increased
comfort for occupants.
Fan speed setting by remote controller (four levels)
Lo
Mi2
Mi1
Hi
Auto
]Special setting is required for wireless remote controller.
PLA-RP ] ] BA
Quiet Operation
Less Cold Draft
An improved airflow path and powerful highcapacity flow fan contribute to the realisation of
quieter operation.
The horizontal airflow function prevents
cold drafts from striking the body directly,
PLA-RP60/71/100/125/140BA
thereby
keeping the body from becoming over-chilled.
“Pure White” Colour
Wide Airflow
Advancements in PLA Series
improve
Horizontal
airflow and
Wide-angle
outletsstyle
distribute
airflow performance for ensured
prevents
drafty
feeling
to all corners
of the
room.
Stylish, pure white-coloured panels and wired remo
indoor comfort.
The outlets are larger than those of previous
ent a clean, streamlined image that is a suitable ma
models and the shape has been improved for
Independent Vane Direction
better Using
wide-angle
wiredventilation.
remote controller,
set airflow direction for each vane
Setting
Wide Airflow
Independent Vane Direction Setting
(manual setting also possible)
Wide-angle outlets distribute airflow
] Wired remote controller Previous
model
(PAR-31MAA) has Independent
Vane Direction Setting.
This function is only available
when indoor unit connects
with PUHZ series.
Use to
the
controller
to set
all wired
cornersremote
of the room,
ensuring
the airflow
of each
vane indethe roompattern
is sufficiently
cooled/heated.
pendently.
Easily
adjust
to the inHorizontal
airflow
and aairflow
fan speed
20%
compared
to
teriorreduced
layout by
and
seasonal
conditions,
to
models
also contribute
help conventional
ensure an even
temperature
distrito increased comfort for occupants.
bution.
4-way Ceiling Cassette
Horizontal
flow
Fixed
Use the wired remote controller to set the airflow pattern of each vane
independently. Easily adjustOther
airflow Features
to the interior layout and seasonal
conditions, to help ensure an even temperature distribution.
• Stylish
indoor-unit
covers
unit is turned
Using wired remote controller,
set airflow
directionvane
for each
vane(when
(manual
setting also possible). *Wired
remote controller
(PAR-33MAA-J)
has
• Maximum
upward
draining of 850mm
independent Vane Direction
Setting. This
function
is only available
when
• Wireless
remote
controller
available
indoor unit connects with PUHZ
Series.
• Duct flange for Fresh-air Intake
• Branch duct
Set by remote Vertical
flow
controller
Horizontal Flow
Settings can be changed anytime
Wave
Airflow Mode for Heating
using a wired remote controller.
Automatic Grille Lowering
Function (Option)
The airflow direction at each outlet changes intermittently, providing
a consistent
Wave
Airflowtemperature
Mode forthroughout
Heatingthe room.
Settings can be
changed at any
time via a wired
remote controller.
The airflow direction at “Wave Airflow” operation image
each outlet changes intermittently, providing a conVertical
Vertical Vertical Vertical
s
i
s
t Simultaneous
e
n horizontal
t
and vertical operation
ensure
flow
flow
flow
flow
a comfortable
from corner
toand
corner
Simultaneous
horizontal
vertical operation ensure
the room
temperature throughout
A
A'
Swing mode
Elevating (up-down)
controller
A
A
A'
Temperature gap with uneven
temperature distribution
Vertical flow
2 0 °C
Temperature gap is decreased,
and room is warmed uniformly
Swing mode
2 4 °C
2 8 °C
capable
of stopping at eight different heights is available to simplify filter maintenance.
The horizontal airflow function prevents cold drafts from striking the body
directly, thereby keeping the body temperature at a comfortable level.
• Wave
control
effect thermograph
Wave
Controlled
Effect Thermograph
Vertical flow
Set by Easy to use/Simple maintenance
Remote An automatic grille lowering function
Vertical Flow
Controller
Less Cold Draft
a comfortable room from corner to corner.
A'
Packaged elevating (up-down)
controller
in the grille ( PLP-6BAJ )
Horizontal airflow prevents draughty
feeling.
can be used when indoor unit
connects with PUHZ series and
SUZ series.
The horizontal airflow function prevents
cold drafts from striking the body directly,
thereby keeping the body from becoming over-chilled.
Specifications: 4-way ceiling-cassette (PLA)
16
Indoor unit
PLA-RP60BA
PLA-RP71BA
PLA-RP71BA
Outdoor unit
SUZ-KA60VAD
SUZ-KA71VAD
PUHZ-RP71VHA5
Function
Capacity (min.-max.)
( kW )
Input
( kW )
Fixed
Cooling
Heating
Cooling
Heating
Cooling
6.1 (2.3-6.3)
6.9 (2.5-8.0)
7.1 (2.8-8.1)
8.0 (2.6-10.2)
7.1 (3.3-8.1)
Heating
Wired remote controller
(PAR-31MAA) has automatic
grille lowering function.
This function is only available
when indoor unit connects with
PUHZ series.
Horizontal
PLA-RP100BA
airflow
PLA-RP125BA
prevents drafty feeling
PUHZ-RP125V/YKA2
PUHZ-RP100V/YKA2
Cooling
Heating
Cooling
Heating
C
8.0 (3.5-10.2) 10.0 (4.9-11.4) 11.2 (4.5-14.0) 12.5 (5.5-14.0) 14.0 (5.0-16.0) 13.0
1.78
1.97
2.07
2.19
2.09
2.17
2.50
2.95
3.80
3.71
Rated EER/COP
3.43
3.50
3.43
3.65
3.40
3.69
4.00
3.80
3.29
3.77
Rated AEER/ACOP
3.36
3.44
3.38
3.60
3.22
3.49
3.67/3.63
3.54/3.50
3.10/3.08
3.56/3.54
3
airflow
ty feeling
4-way cassettes can be equipped with the i-see Sensor,
a radiation-based sensor that monitors floor-level
temperatures throughout the room to
ensure room comfort.
4-way cassettes can be
i-see Sensor works to
equipped
i-see
ensurewith
eventhe
temperature
Sensor
that monitors
distribution
and save
energytemperatures
(requires optional
floor-level
ote controller,
corner panel)
throughout
the room to
n for each ensure
vane room comfort.
also possible)
(requires optional corner
panel - PAC-SA1ME-E)
360°
Floor-level temperature
measured throughout the room.
“i-Feel” Temperature Control
Stylish,
pureis white-coloured
panels and
The sensory temperature
calculated by measuring the
air-intake temperature and the floor temperature.
This technology
helps to avoid overcooling
or overheating.
clean,
streamlined
image
that is a suitab
Auto Fan Speed Mode
controller
Independent
i-see Sensor improves energy efficiency and enhances
n Setting.room comfort (Optional)
nly available
The i-see Sensor is an innovative Mitsubishi Electric technology
that monitors the temperature throughout the entire room. When
nit connects
series. connected to the air conditioner control panel, i-see Sensor works
to ensure even temperature distribution and maximise room comfort
through 360° sensing that covers the whole floor space.
The i-see Sensor rotates 90˚ and takes
5-second measurements to accurately
determine floor-level temperature on all
sides of the room.
Fixed
“Pure White” Colour
The fan speed is adjusted automatically, thereby helping to
maintain a comfortable room environment at all times. At the start
of operation, a high fan speed provides quick cooling/heating of the
room. Once the desired temperature is reached, the fan speed is
reduced for stable cooling/heating and greater comfort.
Other Features
Fan speed setting by remote controller (four levels)
Lo
Mi2
Mi1
Hi
Auto
• Stylish indoor-unit vane covers (when un
Operation upward draining of 850mm
•Quiet
Maximum
An improved airflow path and powerful
capacity flow fanremote
contribute to a controller available
•highWireless
quieter operation.
• Duct flange for Fresh-air Intake
“Pure White” Colour
•Stylish,
Branch
duct panels and wired remote controller present
pure white-coloured
A special setting is required for wireless remote controller
Power Flow Fan
rtical
w
a clean, streamlined image that is a suitable match for any interior.
Other Features
• Stylish indoor unit vane covers (when unit is turned off)
5 second
measurement
5 second
measurement
5 second
measurement
5 second
measurement
•The i-see Sensor calculates the temperature by measuring the
infrared rays emanating from the walls and floors, and measuring
the floor-level temperature.
•The sensor rotates 360˚ once every two minutes when there is
significant temperature disparity and once every five minutes when
a stable, even temperature has been reached.
Without i-see Sensor
Only intake-air temperature
Only
temperature at the
at theintake-air
ceiling is measured,
ceiling
resulting in
resultingisin measured,
uneven
uneven temperature distribution.
temperature distribution.
Vertical
flow
tion ensure
With i-see Sensor
Both floor-level and intake-air
Both
floor-level
intake-air temtemperatures
areand
measured,
peratures
measured,
providing are
operation
that providing
creates operation that creates a comfortable
a comfortable room environment
room environment from ceiling to floor.
from ceiling to floor.
Indoor Indoor
temperature
temperature
detecting
sensor
detecting
sensor
Indoor Indoor
temperature
temperature
detecting
sensor
detecting
sensor
Area in which the
sensor checks
360˚C
sensing
sensing
Area which the
“i-see Sensor”
checks
2.7m
2.7m
11.5m
11.5m
Area in which the
i-see sensor checks
Heating
Heating
Set temperature: 23°C
without i-see Sensor
1 3 °C
2 5 °C
Set temperature: 20°C with
i-see Sensor + Auto Fan Speed
3 7 °C
1 3 °C
2 5 °C
3 7 °C
Automatic Grille Lowering
Function (Option)
• Maximum upward draining of 850mm
• Wireless remote controller available
• Duct flange for fresh-air intake
• Branch duct
Easy to use/Simple maintenance
An automatic grille lowering function ca
stopping at eight different heights is ava
simplify filter maintenance.
Automatic Grille Lowering Function (Optional)
Easy to use, simple to maintain. An automatic grille lowering function
capable of stopping at eight different heights is available to simplify
filter maintenance.
Wired remote controller
(PAR-33MAA-J) has automatic
grille lowering function.
This function is only available
when indoor unit connects with
PUHZ series.
1.2m
Packaged elevating
(up-down) controller in the
grille (PLP-6BAJ) can be used
when indoor unit connects with
PUHZ series and SUZ series.
2.0m
1.6m
Elevating (up-down)
controller
Packaged elevating (up-down)
controller in the grille (PLP-6BAJ) can
be used when indoor unit connects
with PUHZ series and SUZ series.
2.4m
2.8m
3.2m
Wired remote con
3.6m
(PAR-31MAA) has
4.0m
lowering
function
This function is on
when
indoor unit
Automatic elevation to
four meters
PUHZ series.
17
PEAD Series
CEILING-CONCEALED
PEAD-RP71/100/125/140JAAD
The thin, ceiling-concealed PEAD Series units are the answer for buildings
with limited ceiling installation space and wide-ranging external static pressure.
Compact Indoor Units
The height of the PEAD (7.1kW-14.0kW) models has been unified to
250mm. Compared to the previous PEA-RP models, the height has
been reduced by as much as 178mm, making installation possible in
low ceilings with minimal clearance space.
250mm
PEA-RP71-140EAQ
PEAD-RP71-140JAAD
Height reduced by up to 178mm
Lighter Weight
Compared to the previous PEA-RP·EAQ (7.1kW-14.0kW) models,
unit weight has been reduced by an average of 27kg. This significant
weight reduction allows for increased ease of installation.
Five-stage external static pressure conversions and three fan speed
selections are available. Capable of being set to a maximum of 125Pa,
units are applicable to a wide range of building types.
High Energy-Saving Efficiency
Compared to the previous PEA-RP·EAQ (7.1kW-14.0kW) models,
PEAD-RP models achieve enhanced energy efficiency through adopting
a highly efficient DC fan motor. This contributes to a reduction in
electricity consumption.
Capacity
7.1 kW
10.0 kW
Drainage Pump Installed as Standard
The drainage pump can lift water up
to 700mm from the lower surface
of the indoor unit's main body.
12.5 kW
491mm
Max.
700mm
209mm
18
Wide Selection of Fan Speeds and External
Static Pressure
14.0kW
Rated
EER/COP
Previous PEA-RP
PEAD-RP
Rated EER
2.86
3.50
22% UP
Rated COP
3.35
4.00
19% UP
Rated EER
3.28
3.61
10% UP
Rated COP
3.54
4.12
16% UP
Rated EER
2.95
3.33
13% UP
Rated COP
3.64
4.00
10% UP
Rated EER
2.90
3.32
14% UP
Rated COP
3.74
3.96
6% UP
unit
has
his
oor
the
sier
.
PEA Series
CEILING-CONCEALED
PEA-RP100/125/140GAA, PEA-RP170/200WJA/250WHA
For elegance and style, the PEA Series compliments the room with aesthetically
pleasing ceiling installation and a vast line-up of performance functions.
Freedom
in Installation
Versatile
and easy
installation is possible; for example, it is possiand the
easydistance
installationbetween
is possible;
example, itand
is possible
to
bleVersatile
to adjust
theforair-intake
air-outlet
adjust
distance
betweenairflow
the air-intake
and air-outlet vents to create
vents
to the
create
the optimal
configuration.
A flexible duct design
the optimal airflow configuration.
�
Long
rectangularroom
room
Long
rectangular
Flexible Duct Design Enables Use of High-pressure
Static Fan
A flexible duct design and 150Pa external static high-pressure are
and
150Pa external static high-pressure are
incorporated. The increased variation in airflow options ensures
incorporated. The increased
variation
in airflow
ensures
operation
that best matches
virtually alloptions
room layouts.
operation that best
matches virtually all
room layouts.
Room
with
� Room
withfixed
fixed ceiling
ceiling
fixtures
fixtures
L-shaped
� L-shapedroom
room
Easier Handling
The new ducted fan coil unit (PEA-RP170/200/250) now has a
two-piece construction. This allows separation of the indoor unit
heat exchanger and the fan deck assembly for easier handling in
the roof space.
Must be reassembled and installed prior
to using the system.
Computerised Dehumidification
The fan speed is controlled electronically in dehumidifying mode,
increasing the range and efficiency of dehumidification.
19
PCA Series
CEILING-SUSPENDED
PCA-RP50/60/71/100/125/140KAQ
In addition to the conventional 4-speed setting, units are now
A stylish indoor unit design and airflow settingsequipped
for both
high
with an automatic air-speed adjustment mode. This setand low ceiling interiors expand installation possibilities.
ting automatically adjusts the air-speed to conditions that match
t
h
e
room environment. At the start of heating/cooling
operation,
the
Drain Pump Installation Possible
Stylish Indoor Unit Design
Optional Drain Pump for
airflowFull-Capacity
is set to high-speed
to quickly heat/cool the room. When
Models
A stylish square-like design is adopted for the indoor units of all models.
Drainage outlet
room
temperacan be 600mm
As a result, the units blend in better with the ceiling.
The pumping
height
of the
optionaldrain
Thethe
pumping
height
of the
optional
above ceiling
ture reaches
thehasdedrain
pump
been increased
from
pump has
been
increased
from 400mm
surface
sired 400mm
setting,
the expanding flexibility
to 600mm,
to 600mm, expanding flexibility in choos- Ceiling
location during
airflowin choosing
speed isunitdesurface
ing unit location
during
installation
work. installation work.
creased
automatically for stable comfortPCA-GA
PCA-KA
Units are equipped with a
knock-out
hole that
enables
Units
are equipped
with
a knockIn addition to the conventional 4-speed setting, units are now equipped
the induction of fresh outside-air.
out
hole
that
enables
the
inducwith an automatic air-speed adjustment mode.
Equipped with Automatic Air-Speed Adjustment
tion of fresh outside-air.
This setting automatically adjusts the air-speed to conditions that
match the room environment. At the start of cooling/heating operation,
the airflow is set to high-speed to quickly cool/heat the room.
When the room temperature reaches the desired setting, the airflow
speed is decreased automatically for stable comfortable
cooling/heating operation.
Strong
Start of cooling/heating…
20
Gentle
After room temperature is stabilized…
Outside Air-Intake Characteristics
Static pressure (Pa)
Fresh Outside-Air Intake
50
0
–50
–100
–150
–200
–250
–300
PCA-RP100–140KA
PCA-RP60/71KA
PCA-RP50KA
0
1
2
3
Airflow volume (m 3/min)
Equipped with High/Low Ceiling Modes
Units are equipped with high and low ceiling operation modes that
make it possible to switch the airflow volume to match room height.
The ability to choose the optimum airflow volume makes it possible to
optimise the breezy sensation felt throughout the room.
Capacity
High Ceiling
Standard Ceiling
Low Ceiling
50
3.5m
2.7m
2.5m
60
3.5m
2.7m
2.5m
71
3.5m
2.7m
2.5m
100
4.2m
3.0m
2.6m
125
4.2m
3.0m
2.6m
140
4.2m
3.0m
2.6m
4
PKA Series
WALL-MOUNTED
PKA-RP71/100KAL
Elegant design and compact dimensions are ideal for
offices and stores.
4-way Piping Provides More Flexibility in
Selecting Installation Sites
Auto-Flap Shutter
Wired Remote Controller Available (Optional)
A optional wired remote controller and a terminal block are available to
suit various installation sites.
Installation of the drain pump enables a drain outlet as high as
Closing automatically when the air conditioner is off, therefore creating a
Drain Pump Option Available with All Models
800mm Installation
above the
base of the indoor unit. Drain water can be
flat surface that is aesthetically appealing.
of the drain pump enables a drain outlet as high as 800mm
discharged
easily
even
if the
the wall-mounted
above the base of the indoor
unit.surface
Drain waterwhere
can be discharged
easily
even
if
the
surface
where
the
wall-mounted
unit
does
not
have direct
unit does not have direct access outside, increasing
the degree
Quick Clean Grille
access outside, increasing the degree of freedom for installation.
The intake
cancan
easily
slideslide
out completely,
allowingThis
easyallows easy
The
intakegrille
grillefilter
filter
easily
out completely.
of freedom for installation.
cleaning without any special tools making it easy to clean in minutes, washing
cleaning without any special tools.
in water.
Indoor Unit
800mm
Drain Pump
Front Grille
Filter
21
SLZ /SEZ Series
4-WAY CEILING CASSETTE & COMPACT BULKHEAD
SEZ-KD25/35/50/60/71VAQ(L), SLZ-KA25/50VAQ(L)
Compact, quiet concealed indoor units equipped with cutting
edge control technologies for enhanced comfort.
Air Cleaning Filter
Compact Designs
Models with capacity ranges for different room sizes. The dimensions of
the SLZ are perfect for 2-metre-square installations, and the SEZ unit is
a slim 200mm in height, making it ideal for tight installation spaces.
Dimension Comparison
Width reduced by
110mm
990
Fresh-Air Intake
700
208
200
A duct hole is provided in the main body, making it possible to intake
air from outside.
Height
reduced
by
fresh
70mm
Fresh-air intake
650
MODEL
Detailed drawing of fresh-air intake feature
SEZ-KD35/50
Dimensions in mm
100
3- 2.8 hole
Burring hole
Noise Level
Train
Interior
Quiet
Passenger
Car Interior
Library
Interior
60dB
40dB
(40km/h)
80dB
22
°
120
S Series units offer quiet operation at a hushed noise level of 23dB
(SEZ-KD25/35), ensuring a calm and comfortable environment.
They’re so quiet that you may find yourself checking to see if
they’re on.
118
Impressively Quiet
Drain pipe
Electrical box
Refrigerant pipe
Sound
Human
of Rustling Hearing Limits
Leaves
(Extremely Quiet)
23dB 20dB
10dB
Ceiling surface
25
73.4
Cut-out hole
°
MODEL SLZ-KA25/50
12
0
650
This built-in filter removes dust and other particulates helping to keep
the air clean. Maintenance is as simple as vacuuming. The long-life
filter in SLZ Series air conditioners can be used for approximately
2,500 hours before requiring replacement.
Mr. Slim Inverter Units
MAIN FEATURES
Indoor Unit
Combination
Energy
Saving
Attractive
Air
Quality
Air
Distribution
Convenience
System
Control
Installation
Maintenance
• Standard ○ Optional - Not Available
SLZ-VAQ
SLZ-VAL
SEZVAQ
SEZ-VAL
PLA
Outdoor Unit
SUZ
SUZ
SUZ
SUZ
*7
PUHZ
Felt Temperature Control
(i-see Sensor)
-
-
-
-
○
PEAD
PEA
SUZ
*7
PUHZ
SUZ
*7
PUHZ-KA
○
-
-
-
PKA
PUHZYKM
*7
*4
PCA-KAQ
*7
PUHZ
*7
PUHZ
SUZ
-
-
-
●
●
○
Demand Function
○
○
○
○
●
○
●
○
●
●
Pure White
●
●
-
-
●
●
-
-
-
-
●
●
●
Auto Vane
●
●
-
-
●
●
-
-
-
-
●
●
●
Fresh-Air Intake
●
●
-
-
●
●
-
-
-
-
-
●
●
High-Efficiency Filter
-
-
-
-
○
○
-
-
-
-
-
○
○
Long-Life Filter
●
●
-
-
●
●
●
●
-
-
-
●
●
Filter Check Signal
●
-
-
-
●
●
●
●
-
-
○
●
●
Horizontal Vane
(Auto Swing)
●
●
-
-
●
●
-
-
-
-
●
●
●
High Ceiling Mode
-
-
-
-
●
●
-
-
-
-
-
●
●
Low Ceiling Mode
-
-
-
-
●
●
-
-
-
-
-
●
●
Auto Fan Speed Mode
-
-
●
●
●
●
●
●
-
-
●
●
●
●
●
●
*5
On/Off Operation Timer
●
●
●
●
●
●
●
●
●
●
Auto Change Over *1
●
●
●
●
●
●
●
●
●
-
●
●
●
Auto Restart
●
●
●
●
●
●
●
●
●
●
●
●
●
Low-Temperature Cooling
●
●
●
●
●
●
●
●
●
●
●
●
●
Low-Noise Operation
(Outdoor Unit)
-
-
-
-
●
-
●
-
●
●
●
●
-
Rotation, Back-up and 2nd
Stage Cut-in Function
-
-
-
-
○
-
○
-
-
-
○
●
-
PAR-33MAA-J Control *2
○
-
○
○
○
○
○
○
○
○
○
○
○
PAC-YT52CRA Control *2
○
-
○
○
○
○
○
○
○
○
○
○
○
PAC-ZC40/80H (L)-E
Control
-
-
-
-
-
-
○
○
○
○
-
-
-
System Group Control *2
○
○
○
○
●
○
●
○
●
●
○
●
○
M-NET Connection *2
○
○
○
○
○
○
○
○
○
●
○
○
○
Reuse of Existing Wiring
-
-
-
-
○
-
○
-
-
-
○
○
-
Drain Pump
●
●
○
○
●
●
-
-
-
-
○
○
○
Pump Down Switch
-
-
-
-
●
-
●
-
●
-
●
●
-
Flare Connection
●
●
●
●
●
●
●
●
●
-
●
●
●
Self-Diagnosis Function
(Check Code Display)
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Error History
●
●
●
*1 When multiple indoor units connected to an MXZ outdoor unit are running
at the same time, simultaneous cooling and heating is not possible.
*2 Please refer to “System Control” on page 24 for details.
*3 Not available with PEA-RP170/200WJA and PEA-RP250WHA models.
*4 Schedule timer not available. External contact only.
●
●
●
●
●
●
*3
●
●
*6
*5 Remote controller timer function only.
*6 Only error display on remote controller.
*7 PUHZ-RP250 is excluded. PUHZ-RP·VHA5R1-A, PUHZ-RP·V/YKA2R1-A
are only demand response capable with the demand function.
Please contact Mitsubishi Electric Australia Pty. Ltd. for details.
23
SYSTEM CONTROLS (SUZ and Mr. Slim Power Inverter only)
Versatile system controls can be realised by using optional parts, relay circuits, control panels, etc
MAJOR SYSTEM CONTROL
System Examples
A
Indoor Unit
S Series & P Series
Indoor Unit
P Series Indoor Unit
Outdoor Unit
S Series Outdoor
P Series Outdoor
PAR-33MAA-J
Control
PAC-YT52CRA
Control
Standard equipment
(for indoor units compatible
with wired remote controllers)
PAR-33MAA-J
PAC-YT52CRA
B
System
Group
Control
C
M-NET Connections
• One remote controller can control multiple
air conditioners with the same settings
simultaneously.
MAC-397IF-E
MAC-333IF-E
PAR-33MAA-J
PAC-YT52CRA
PAR-33MAA-J
PAC-YT52CRA
Outdoor
unit
Outdoor
unit
Indoor unit
Indoor unit
Indoor
unit
PAR-33MAA-J PAR-33MAA-J
PAC-YT52CRA PAC-YT52CRA
City Multi
indoor unit
PAR-33MAA-J PAR-33MAA-J
PAC-YT52CRA PAC-YT52CRA
MELANS
system controller
AE-200E
• One remote controller can control up to 16
refrigerant systems.
• Up to two remote controllers can
be connected.
Indoor
unit
MAC-333IF-E
Details
Group of air conditioners can be controlled by
MELANS system controller (M-NET).
M-NET adapter
PAC-SF81MA-E
MELANS
system controller
AE-200E
Major Optional
Parts Required
• PAR-33MAA-J
(Wired remote controller)
• PAC-YT52CRA
(Wired remote controller)
S Series Outdoor Unit
• MAC-397IF-E/MAC-333IF-E (Interface)
• PAR-33MAA-J (Wired remote
controller)
• PAC-YT52CRA
(Wired remote controller)
P Series Outdoor Unit
• PAR-33MAA-J
(Wired remote controller)
S Series Outdoor Unit
• MAC-333IF-E
• MELANS System controller
P Series Outdoor Unit
• PAC-SF83MA-E (M-NET converter)
• MELANS System controller
FOR P SERIES AND S SERIES INDOOR UNITS
System Examples
A
Wired
Remote Controller
2 Remote
Controller Control
With two remote
controllers, control
can be performed
locally and remotely
from two locations.
B
PAR-SL97A-E
PAR-33MAA-J
PAC-YT52CRA
Operation Control
by Level Signal
Air conditioner can be
started/stopped remotely.
In addition, On/Off
operation by local
remote controller can be
prohibited/permitted.
PAR-33MAA-J
PAC-YT52CRA
* Set "Main" and "Sub"
remote controllers.
(Example of 1 : 1 system)
* When using wired and wireless
remote controllers
(Example of Simultaneous Twin)
Relay box (to be purchased locally)
Relay box (to be purchased locally)
Adapter for
remote
On/Off
Adapter for
remote
On/Off
Remote
control
panel
Wired remote
controller
(Example of 1 : 1 system x 2)
C
Remote
control
panel
PAR-SL97A-E
(Example of 1 : 1 system x 2)
Wired remote
controller
(Example of 1 : 1 system x 2)
D
Connector
cable for
remote
display
Connector
cable for
remote
display
Remote
control
panel
Remote operation adapter/
Connector cable for remote display +
Relay box
Remote
control
panel
PAR-SL97A-E
Remote
display
panel
PACYT52CRA
PAR-33MAA-J
(Example of 1 : 1 system)
• Both wired and wireless remote controllers
can be used in combination.
Remote operation adapter/
Connector cable for remote display +
Relay box
Remote
display
panel
PAR-SL97A-E
(Example of Simultaneous Twin)
Major Optional
Parts Required
• Wired Remote Controller
PAR-33MAA-J, PAC-YT52CRA
(for PKA, PAC-SH29TC-E is required)
• Wireless Remote Controller
PAR-SL97A-E (for SEZ and PLA-RP)
• Wireless Remote Controller Kit for
PCA PAR-SL948-E
• Operation other than On/Off
e.g. adjustment of temperature, fan speed,
and airflow) can be performed even when
remote controller operation is prohibited.
• Adapter for remote On/Off
PAC-SE55RA-E
• Timer control is possible with an
external timer.
• Remote control panel
(to be purchased locally)
• The pulse signal can be turned On/Off.
• Connector cable for remote display
PAC-SA88HA-E/PAC-725AD
(10 pcs. x PAC-SA88HA-E)
• Operation/emergency signal can be
received at a remote location.
• Relay box
(to be purchased locally)
• Relay box
(to be purchased locally)
• Remote control panel
(to be purchased locally)
(Example of 1 : 1 system x 2)
Remote Display of
Operating Status
Operating status can
be displayed at
a remote location.
• Up to two remote controllers can be
connected to one group.
Relay box (to be purchased locally)
Relay box (to be purchased locally)
Operation Control
by Pulse Signal
Details
Wireless
Remote Controller
• Operation/emergency signal can be
received at a remote location (when channeled
through the
PAC-SF40RM
No-voltage signal,
when channeled through the
PAC-SA88HA-E
12V DC signal).
• Remote display panel
(to be purchased locally)
• Connector cable for remote display
PAC-SA88HA-E/ PAC-725AD
(10 pcs. x PAC-SA88HA-E)
• Relay box (to be purchased locally)
• Remote operation adapter
PAC-SF40RM
*Unable to use with wireless remote controller.
E
• Weekly Timer: On/Off and up to 8 pattern
temperatures can be set for each
calendar day. (Initial setting)
Timer Operation:
Allows On/Off
operation with timer
24
*For control by an external timer,
refer to B: Operation Control by
Level Signal.
PAR-33MAA-J
(Example of 1 : 1 system)
-
• On/Off Timer: On/Off can be set once each
within 72hr. in intervals of 5-minute units.
• Auto-Off Timer: Operation will be switched
off after a certain time elapse. Set time can
be changed from 30 min. to 4 hr. at 10 min.
intervals.
*Simple Timer and Auto-off Timer cannot be used at the
same time.
Standard functions of PAR-33MAA-J
MAIN FEATURES OF MR. SLIM INVERTER UNITS
Outdoor Unit
SUZ-KA25VAD
SUZ-KA35VAD
SUZ-KA50VAD
External Finish
Munsell 3.0Y 7.8/1.1
Power Supply
Single-phase, 50Hz, 230V
Compressor Output (kW)
0.65
0.9
0.9
1.2
568/534
551
817
960/816
950/800
Cooling Mode
46
47
53
55
Heating Mode
46
48
55
55
59
61
68
69
Sound Power Level (dB)
Dimensions
SUZ-KA71VAD
0.55
Airflow (cooling/heating) (L/S)
Sound Pressure
Level (dB)
SUZ-KA60VAD
Height (mm)
550
850
880
Width (mm)
800
840
840
Depth (mm)
285
330
330
30
Weight (kg)
33
53
50
53
7
Chargeless Piping Length (m)
Max. Piping Length (m)
20
30
Breaker Size (A)
10
20
*Above specifications are for outdoor units only.
Outdoor Unit
PUHZ-RP71VHA5
PUHZ-RP100V/YKA2
PUHZ-RP125V/YKA2
External Finish
Munsell 3.0Y 7.8/1.1
Power Supply
V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V
Compressor Output (kW)
1.6
1.9
1,000
1,830
Cooling Mode
47
49
50
50
Silent Mode
44
46
47
47
Heating Mode
48
51
52
52
66
69
70
70
Airflow (cooling/heating) (L/S)
Sound Pressure
Level (dB)
Sound Power Level (dB)
Dimensions
PUHZ-RP140V/YKA2
2.4
2,000
Height (mm)
943
1,338
Width (mm)
950
1,050
Depth (mm)
330
330
Weight (kg)
67
Chargeless Piping Length (m)
30
30
Max. Piping Length (m)
50
75
Protection Device
Rated Running Current (A)
(cooling/heating)
Breaker Size (A)
2.9
V: 118 Y:119
V: 120 Y:121
Discharge thermo, HP switch
9.05/9.64
25
V: 12.64/13.58
Y: 4.42/4.75
V: 16.36/16.90
Y: 5.73/5.91
V: 32 Y:16
V: 17.17/19.23
Y: 6.01/6.73
V: 40 Y:16
Sound Pressure Level
Sound pressure measurements were conducted in an anechoic chamber.
The actual noise level depends on the distance from the unit and the acoustic environment.
*Above specifications are for outdoor units only.
25
SPECIFICATIONS
Outdoor Units
Outdoor Unit
External Finish
PUHZ-RP170V/YKA2
PUHZ-RP200YKA2
PUHZ-RP250YKM
Munsell 3.0Y 7.8/1.1
Munsell 3.0Y 7.8/1.1
Munsell 5.0Y 8.0/1.0
or similar
Power Supply
V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V
Compressor Output (kW)
3.0
3.6
6.9
2,330
2,330
2,917
Cooling Mode
58
58
58
Silent Mode
56
56
48
Heating Mode
59
59
58
76
76
78
Height (mm)
1,338
1,338
1,650
Width (mm)
1,050
1,050
920
Depth (mm)
330
330
740
V: 127 Y:131
136
199
Chargeless Piping Length (m)
30
30
0
Max. Piping Length (m)
75
75
75
Airflow (cooling/heating) (L/S)
Sound Pressure
Level (dB)
Sound Power Level (dB)
Dimensions
Weight (kg)
Protection Device
Discharge thermo, HP switch
Rated Running Current
(cooling/heating) (A)
Breaker Size (A)
V: 19.4/23.9 Y: 6.8/8.3
8.2/9.7
9.7/11.0
V: 40 Y:32
32
32
*Above specifications are for outdoor units only.
Notes on All Specifications
Total input based on the indicated voltage (indoor/outdoor)
Rating conditions (AS/NZS 3823)
Cooling
Indoor:
27°C DB, 19°C WB
Outdoor:
35°C DB
Heating
Indoor:
Outdoor:
20°C DB
7°C DB, 6°C WB
50Hz
Indoor
Outdoor
Single-phase, 230V
Single-phase, 230V/
Three-phase, 400V
Refrigerant piping length (one-way): 5m
For PUHZ-RP250YKM: 7.5m
Guaranteed Operating Range
SUZ-KA
Cooling
Heating
25/35
50
60/71
71/100/125/140/170/200
250
Upper Limit (DB)
46°C
43°C
46°C
46°C
46°C
Lower Limit (DB)
-10°C
-15°C
-15°C
-5°C (-15°C)*
-5°C
Upper Limit (DB)
24°C
24°C
24°C
21°C
15.5°C (WB)
Lower Limit (DB)
-15°C
-15°C
-15°C
-20°C
-20°C (WB)
*With the optional air protection guide, the operation at -15˚C outdoor temperature is possible.
26
PUHZ
Sound Pressure Level
Sound pressure measurements were conducted in an anechoic chamber.
The actual noise level depends on the distance from the unit and the acoustic environment.
SPECIFICATIONS
Outdoor Units
Part Name
Model Name
Application Name
PAC-SG59SG-E
PUHZ-RP71
PAC-SH96SG-E
PUHZ-RP100/125/140/170/200
PAC-SH51SP-E
PLA-RP
PAC-SH63AG-E
PUHZ-RP71
PAC-SH95AG-E
PUHZ-RP100/125/140/170/200
PAC-SK52ST
PUHZ-RP
71/100/125/140/170/200
PAC-SG64DP-E
PUHZ-RP71
PAC-SH97DP-E
PUHZ-RP100/125/140/170/200
PAC-SH94DM-E
PKA-RP
PAC-SH83DM-E
PCA-RP50KAQ
PAC-SH84DM-E
PCA-RP
71/100/125/140KAQ
PAC-SH85DM-E
PCA-RP60KAQ
PAC-KE07DM-E
SEZ-KD
Drain Socket
PAC-SG61DS-E
PUHZ-RP
71/100/125/140/170/200
Flange for
Fresh-Air Intake
PAC-SH65OF-E
PLA-RP
Liquid Refrigerant
Dryer for Pipe
Ø9.52
PAC-SG82DR-E
Air Discharge
Guide
Air Outlet Shutter
Plate
Air Protection
Guide
Control/Service
Tool
Centralised
Drain Pan
Drain Pump
PUHZ-RP
Part Name
Model Name
Application Name
PAC-KE93TB-E
PEAD-RP71
PAC-KE94TB-E
PEAD-RP100/125
PAC-KE95TB-E
PEAD-RP140
i-See Sensor Corner
Panel
PAC-SA1ME-E
PLA-RP
Shutter Plate
PAC-SH51SP-E
PLA-RP
9.5212.7
PAC-SG73RJ-E
PUHZ-RP
71/100/125/140/170/200
15.8819.05
PAC-SG75RJ-E
PUHZ-RP
71/100/125/140
M-Net Converter
PAC-SF83MA-E
PUHZ-RP
71/100/125/140/170/200
Multi-Function
Casement
PAC-SH53TM-E
PLA-RP
Filter Box
Joint
Pipe
PAC-SG94HR-E
PKA-RP
PAC-SG96HR-E
PCA-RP50/60/71
100/125/140KAQ
PAC-SG97HR-E
PEAD-RP, PEA-RP
PAC-SH52HR-E
PLA-RP
Remote On/Off
Adapter
PAC-SE55RA-E
All indoor units
Remote Operation
Adapter
PAC-SF40RM-E
All indoor units*2
(excluding PKA-RP)
Remote Sensor
PAC-SE41TS-E
All indoor units
(excluding PEA-RP•GAA)
Power Supply
Terminal Kit
Wi-Fi Interface
MAC-559IF-E
All indoor units
(excluding PEA-RP250WHA)
MA & Contact
Terminal Interface
MAC-397IF-E
SLZ-KA, SEZ-KD,
PLA-RP60/71*1
PEAD-RP71*1,
PCA-RP50/60/71*1
Space Panel
PAC-SH48AS-E
PLA-RP
Terminal Block
PAC-SH29TC-E
PKA-RP for wired
remote controller
Connector Cable for
Remote Display
PAC-SA88HA-E
All indoor units
MAC-399IF-E
SLZ-KA, SEZ-KD,
PLA-RP60/71*1
PEAD-RP71*1,
PCA-RP50/60/71*1
PAR-33MAA-J
Wired Remote Control
All indoor units
(excluding SLZ-VAL
and SEZ-VAL)
PAC-YT52CRA
All indoor units
(excluding SLZ-VAL
and SEZ-VAL)
M-Net Interface
M-Net & Terminal
Interface
MAC-333IF-E
SLZ-KA, SEZ-KD,
PLA-RP60/71*1
PEAD-RP71*1,
PCA-RP50/60/71*1
Wireless Remote
Controller
PAR-FL32MA-E
PEAD-RP, PEA-RP
Wireless Remote
Controller Signal
Sender
PAR-SL97A-E
Wireless Remote
Controller Signal
Receiver
High Efficiency
Filter
High Efficiency
Filter Element
SEZ-KD, PLA-RP
PAC-ZC40H-E
Zone Controller
(Interface & Remote
Controller)
PAC-ZC80H-E
PAC-ZC40L-E
PEAD-RP, PEA-RP
PAC-ZC80L-E
PAR-SA9CA-E
SEZ-KD, PEAD-RP, PEA-RP
PAR-SA9FA-E
PLA-RP
PAC-SH88KF-E
PCA-RP50KAQ
PAC-SH89KF-E
PCA-RP60/71KAQ
PAC-SH90KF-E
PCA-RP100/125/140KAQ
PAC-SH59KF-E
PLA-RP
Zone Remote
Controller
PAC-ZC01M-E
PEAD-RP, PEA-RP
Wireless Remote
Controller Kit
(Sender & Receiver)
PAR-SL94B-E
PCA-RP
Power Supply Unit
PAC-SC50KUA
All outdoor units
Multiple Remote
Controller Adapter
PAC-72SAD
All indoor units
Interface For DRED
DRC-101A
SUZ-KA•VAD
*1 P Series indoor units can be used in combination with SUZ outdoor units.
*2 Unable to use with wireless remote controller.
27
SPECIFICATIONS
Refrigerant Piping
Between Indoor & Outdoor Units
Capacity
28
Max. Height Difference (m)
Max. Piping
Length (m)
SUZ-KA25
12
20
SUZ-KA35
12
20
SUZ-KA50
30
30
SUZ-KA60
30
30
SUZ-KA71
30
30
PUHZ-RP71
30
50
PUHZ-RP100/125/140
30
75
PUHZ-RP170/200
30
75
PUHZ-RP250
30
75
Pipe Size OD (mm)
Thickness (mm)
Liquid: ø 6.35
t 0.8
ø 9.52
t 0.8
Liquid: ø 6.35
t 0.8
Gas:
ø 9.52
t 0.8
Liquid: ø 6.35
t 0.8
Gas:
ø 12.7
t 0.8
Liquid: ø 6.35
t 0.8
Gas:
Gas:
ø 15.88
Liquid: ø 9.52
Gas:
ø 15.88
Liquid: ø 9.52
Gas:
ø 15.88
Liquid: ø 9.52
Gas:
ø 15.88
t 1.0
t 0.8
t 1.0
t 0.8
t 1.0
t 0.8
t 1.0
Liquid: ø 9.52
t 0.8
ø 25.4
t 1.0
Liquid: ø 9.52
t 0.8
ø 22.2
t 1.0
Gas:
Gas:
SPECIFICATIONS
Amount of Necessary Refrigerant (R410A: kg)
Factory Charged
Piping Length
Additional Charged
7m
10m
15m
20m
25m
30m
SUZ-KA25
0.8
0.15
0.3
0.45
-
-
SUZ-KA35
1.05
0.15
0.3
0.45
-
-
SUZ-KA50
1.6
0.06
0.16
0.26
0.36
0.46
SUZ-KA60
1.8
0.06
0.16
0.26
0.36
0.46
SUZ-KA71
1.8
0.165
0.44
0.715
0.99
1.265
Factory Charged
Piping Length
Calculation
Xg=30g/m x (length-5) m
Xg=20g/m x (length-7) m
Xg=55g/m x (length-7) m
Additional Charged
10-30m
31-40m
41-50m
51-60m
61-75m
PUHZ-RP71
3.5
0.6
1.2
-
-
PUHZ-RP100/125/140
5.5
0.6
1.2
1.8
2.4
Factory Charged
Piping Length
PUHZ-RP170/200
Additional Charged
10-30m
31-40m
41-50m
51-60m
61-70m
7.7
0.9
1.8
2.7
3.6
In the Case of PUHZ-RP250YKM
Calculation of additional refrigerant charge
• Calculate the amount of additional charge based on the length of the piping extension and the size of the refrigerant line.
• Use the table below as a guide when calculating the amount of additional charging and charge the system accordingly.
• If the calculation results in a fraction of less than 0.1kg, round up to the next 0.1kg.
For example, if the result of the calculation was 11.38kg, round the result up to 11.4kg.
Additional Charge
Additional refrigerant
charge
(kg)
Liquid pipe size
Total length of ø9.52x0.06
=
(m) x 0.06(kg/m)
+ 3.0kg
Factory Charge: 9kg
29
SPECIFICATIONS
4-way Ceiling Cassette (PLA Series)
PLA-RP60BA
PLA-RP71BA
PLA-RP71BA
PLA-RP100BA
PLA-RP125BA
PLA-RP140BA
SUZ-KA60VAD
SUZ-KA71VAD
PUHZ-RP71VHA5
PUHZ-RP100/YKA2
PUHZ-RP125/YKA2
PUHZ-RP140/YKA2
Indoor Unit
Outdoor Unit
Function
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Capacity (min-max)
(kW)
6.1
(2.3-6.3)
6.9
(2.5-8.0)
7.1
(2.8-8.1)
8.0
(2.6-10.2)
7.1
(3.3-8.1)
8.0
(3.5-10.2)
10.0
(4.9-11.4)
11.2
(4.5-14.0)
12.5
(5.5-14.0)
14.0
(5.0-16.0)
13.0
(6.2-15.3)
16.0
(5.7-18.0)
Input
(kW)
1.78
1.97
2.07
2.19
2.09
2.17
2.50
2.95
3.80
3.71
3.97
4.43
Rated EER/COP
3.43
3.50
3.43
3.65
3.40
3.69
4.00
3.80
3.29
3.77
3.27
3.61
Rated AEER/ACOP
3.36
3.44
3.38
3.60
3.22
3.49
3.67/3.63
3.54/3.50
3.10/3.08
3.56/3.54
3.10/3.08
3.44/3.42
4.13/4.05
AEER/ACOP (part-load %) *
3.95/3.89
V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V
Power Supply
Airflow (Lo-Mi2-Mi1-Hi)
L/S
200-233-267-300
233-267-300-350
233-267-300-350
334-384-434-501
367-417-467-517
400-434-484-534
Sound Pressure Level
(dB)
28-29-31-32
28-30-32-34
28-30-32-34
32-34-37-40
34-36-39-41
36-39-42-44
Dimensions
Unit: 258, Panel: 35
Unit: 298, Panel: 35
Height
(mm)
Width
(mm)
Unit: 840, Panel: 950
Depth
(mm)
Unit: 840, Panel: 950
Weight
Unit: 23, Panel: 6
(kg)
Unit: 25, Panel: 6
Unit: 27, Panel: 6
*MEPS compliant at part load.
*SUZ-KA·VAD is potentially demand response capable unit. DRC-101A is required.
Sound Pressure Level
Sound pressure measurements were conducted in an anechoic chamber.
Ceiling-Concealed (PEAD Series)
Indoor Unit
Outdoor Unit
PEAD-RP71JAAD
PEAD-RP71JAAD
PEAD-RP100JAAD
PEAD-RP125JAAD
PEAD-RP140JAAD
SUZ-KA71VAD
PUHZ-RP71VHA5
PUHZ-RP100V/YKA2
PUHZ-RP125V/YKA2
PUHZ-RP140V/YKA2
Function
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Capacity (min-max)
(kW)
7.1
(2.8-8.1)
8.0
(2.6-10.2)
7.1
(3.3-8.1)
8.0
(3.5-10.2)
10.0
(4.9-11.4)
11.2
(4.5-14.0)
12.0
(5.5-14.0)
14.0
(5.0-16.0)
13.0
(6.2-15.3)
16.0
(5.7-18.0)
Input
(kW)
2.10
2.04
2.03
2.00
2.77
2.72
3.60
3.50
3.91
4.04
Rated EER/COP
3.38
3.92
3.50
4.00
3.61
4.12
3.33
4.00
3.32
3.96
Rated AEER/ACOP
3.33
3.86
3.31
3.78
3.34/3.31
3.81/3.78
3.14/3.11
3.76/3.74
3.09/3.07
3.76/3.73
3.68/3.63
AEER/ACOP (part-load %) *
V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V
Power Supply
Airflow (Lo-Mid-Hi)
L/S
292-350-417
Sound Pressure Level
492-592-700
533-650-767
(dB)
30-34-39
33-38-42
36-40-44
40-44-49
Return Air Spigot Size
(mm)
1,058x210
1,358x210
1,358x210
1,558x210
Supply Air Spigot Size
(mm)
1,060x178
1,360x178
1,360x178
1,560x178
Dimensions
Weight
Height
(mm)
Width
(mm)
Depth
(mm)
(kg)
250
1,100
Sound Pressure Level
Sound pressure measurements were conducted in an anechoic chamber.
1,400
1,600
732
30
*MEPS compliant at part load.
*SUZ-KA·VAD is potentially demand response capable unit. DRC-101A is required.
30
400-483-567
35/50/70/100/125
External Static Pressure (Pa)
39
40
44
SPECIFICATIONS
Ceiling-Concealed (PEA Series)
PEA-RP100GAA
Indoor Unit
PEA-RP125GAA
PUHZ-RP100V/YKA2
Outdoor Unit
Function
PEA-RP140GAA
PUHZ-RP125V/YKA2
PEA-RP170WJA
PUHZ-RP140V/YKA2
PEA-RP200WJA
PUHZ-RP170V/YKA2
PEA-RP250WHA
PUHZ-RP200V/YKA2
PUHZ-RP250/YKM
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
11.2
(4.5-14.0)
12.5
(5.5-14.0)
14.0
(5.0-16.0)
13.5
(6.2-15.3)
16.0
(5.7-18.0)
16.0
(9.0-20,0)
20.0
(9.5-22.4)
18.9
(9.0-22.4)
22.4
(9.5-25.0)
22.0
(11.2-27.0)
25.0
(12.5-29.0)
Capacity (min-max)
(kW)
10.0
(4.9-11.4)
Input
(kW)
2.60
2.51
3.97
3.27
4.19
3.90
5.00
6.00
5.92
6.89
6.11
6.89
3.85
4.46
3.15
4.28
3.22
4.10
3.20
3.33
3.19
3.25
3.60
3.62
3.54/3.51
4.11/4.07
2.98/2.96
4.01/3.98
3.06/3.04
3.88/3.86
3.16/3.11
3.22/3.18
3.04
3.12
3.27
3.37
Rated EER/COP
*1
Rated AEER/ACOP
AEER/ACOP (part-load %)
3.69/3.63
*2
3.67/3.61
3.71
V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V
Power Supply
Airflow (Lo-Mid-Hi)
L/S
560-700
(dB)
39-42
50Pa: 800-1,000, 100Pa: 716-900, 150Pa: 683-866
50/100/150
External Static Pressure (Pa)
Sound Pressure Level
*3
833-1,017-1,200
967-1,183-1,400
60/75/100/150
42-45
38-41-44
40-43-46
Return Air Spigot Size
(mm)
1,102x330
1,110x420
Supply Air Spigot Size
(mm)
921x250
1,100x340
Dimensions
Height
(mm)
400
470
Width
(mm)
1,400
1,370
Depth
(mm)
634
1,120
(kg)
63
108
Weight
*1 Rated EER/COP for PEA-RP170/200WJA/250WHA are measured at ESP 75 Pa.
*2 MEPS compliant part load.
Sound Pressure Level
*3 Sound Pressure Level for PEA-RP125/140GAA are measured in an anechoic chamber at ESP 50Pa.
Sound Pressure Level for PEA-RP170/200WJA/250WHA are measured in an anechoic chamber at ESP 150Pa.
Ceiling-Suspended (PCA Series)
Indoor Unit
PCA-RP50KAQ
PCA-RP60KAQ
PCA-RP71KAQ
PCA-RP71KAQ
PCA-RP100KAQ
PCA-RP125KAQ
PCA-RP140KAQ
Outdoor Unit
SUZ-KA50VAD
SUZ-KA60VAD
SUZ-KA71VAD
PUHZ-RP71VHA5
PUHZ-RP100V/YKA2
PUHZ-RP125V/YKA2
PUHZ-RP140V/YKA2
Function
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Capacity (min-max)
(kW)
4.9
(2.3-5.6)
5.5
(1.7-7.2)
5.7
(2.3-6.3)
6.9
(2.5-8.0)
7.1
(2.8-8.1)
7.9
(2.6-10.2)
7.1
(3.3-8.1)
8.0
(3.5-10.2)
10.0
(4.9-11.4)
11.2
(4.5-14.0)
12.0
(5.5-14.0)
14.0
(5.0-16.0)
13.0
(6.2-15.3)
16.0
(5.7-18.0)
Input
(kW)
4.43
1.49
1.68
1.67
2.02
2.06
1.96
1.96
2.21
2.63
3.02
3.66
3.88
3.97
Rated EER/COP
3.29
3.27
3.41
3.42
3.45
4.03
3.62
3.62
3.80
3.71
3.28
3.61
3.27
3.61
Rated AEER/ACOP
3.22
3.22
3.35
3.36
3.39
3.96
3.42
3.44
3.50/3.47
3.46/3.43
3.09/3.07
3.41/3.39
3.10/3.08
3.41/3.39
4.19/4.11
AEER/ACOP (part-load %) *1 *2
3.91/3.85
V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V
Power Supply
Airflow (Lo-Mi2-Mi1-Hi)
L/S
167-183-217-250
250-267-283-317
267-283-300-333
367-400-433-467
383-417-450-483
400-433-483-533
Sound Pressure Level *3
(dB)
32-34-37-40
33-35-37-40
35-37-39-41
37-39-41-43
39-41-43-45
41-43-45-48
Dimensions
Weight
Height
(mm)
Width
(mm)
Depth
(mm)
(kg)
230
960
1,280
1,600
680
25
32
36
38
39
*1 MEPS compliant at part load.
*2 SUZ-KA•VAD is potentially demand response capable unit. DRC-101A is required.
Sound Pressure Level
*3 Sound pressure measurements were conducted in an anechoic chamber.
31
SPECIFICATIONS
Wall-Mounted (PKA Series)
PKA-RP71KAL
PKA-RP100KAL
PUHZ-RP71VHA5
PUHZ-RP100V/YKA2
Indoor Unit
Outdoor Unit
Cooling
Heating
Cooling
Heating
Capacity (min-max)
(kW)
7.1 (3.3-8.1)
8.0 (3.5-10.2)
10.0 (4.9-11.4)
11.2 (4.5-14.0)
Input
(kW)
1.96
2.13
2.90
3.10
Rated EER/COP
3.62
3.76
3.45
3.61
Rated AEER/ACOP
3.42
3.56
3.20/3.17
3.34/3.31
Function
V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V
Power Supply
Airflow (Lo-Mid-Hi)
Sound Pressure Level
Dimensions
L/S
300-333-367
(dB)
39-42-45
333-383-433
41-45-49
Height
(mm)
365
Width
(mm)
1,170
Depth
(mm)
295
(kg)
21
Weight
Sound Pressure Level
Sound pressure measurements were conducted in an anechoic chamber.
4-way Cassette / Compact Bulkhead (SLZ/SEZ Series)
Indoor Unit
Outdoor Unit
Function
Capacity (min-max)
(kW)
Input
(kW)
SLZ-KA25VAQ(L)
SLZ-KA50VAQ(L)
SEZ-KD25VAQ(L)
SEZ-KD35VAQ(L)
SEZ-KD50VAQ(L)
SEZ-KD60VAQ(L)
SEZ-KD71VAQ(L)
SUZ-KA25VAD
SUZ-KA50VAD
SUZ-KA25VAD
SUZ-KA35VAD
SUZ-KA50VAD
SUZ-KA60VAD
SUZ-KA71VAD
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
2.3
(1.5-3.2)
3.1
(1.3-4.5)
4.2
(2.3-5.2)
4.5
(1.7-6.5)
2.5
(1.5-3.2)
3.0
(1.3-4.5)
3.7
(1.4-3.9)
4.2
(1.7-5.0)
5.1
(2.3-5.6)
6.4
(1.7-7.2)
5.6
(2.3-6.3)
7.4
(2.5-8.0)
6.5
(2.8-8.3)
8.1
(2.6-10.4)
0.6
0.82
1.27
1.37
0.75
0.83
1.09
1.13
1.64
1.81
1.77
2.05
2.06
2.18
Rated EER/COP
3.83
3.78
3.31
3.28
3.33
3.61
3.39
3.72
3.11
3.54
3.16
3.61
3.16
3.72
Rated AEER/ACOP
3.65
3.66
3.23
3.22
3.21
3.49
3.31
3.62
3.05
3.48
3.11
3.55
3.10
3.66
AEER/ACOP (part-load %) *
4.32
3.72
V: Single phase, 50 Hz, 230V
Power Supply
Airflow (Lo-Mid-Hi)
L/S
133-150-167
133-150-183
117-150-183
167-208-250
28-31-37
200-250-300
200-267-333
5/15/35/50
30-34-39
23-26-30
23-28-33
30-34-37
30-34-38
30-35-40
Sound Pressure Level
(dB)
Supply Air Spigot Size
(mm)
-
660x150
860x150
1,060x150
Height
(mm)
Unit: 235, Panel: 20
200
200
200
Width
(mm)
Unit: 570, Panel: 650
790
990
1,190
Depth
(mm)
Unit: 570, Panel: 650
700
Unit: 16.5, Panel: 3
18
Dimensions
Weight
(kg)
*MEPS compliant at part load.
*SUZ-KA•VAD is potentially demand response capable unit. DRC-101A is required.
Sound Pressure Level
Sound pressure measurements were conducted in an anechoic chamber.
32
92-117-150
-
External Static Pressure (Pa)
700
21
700
23
27
Warm, even heat in winter
and cool, comfort in
summer is only a phone
call or click away.
Simply contact your nearest Mitsubishi Electric Specialist today and you can find out all there is to know about
how to enhance your living environment. Our specialists are fully qualified to give you all the right advice on
which Mitsubishi Electric Air Conditioning System is right for you.
To locate your nearest Mitsubishi Electric Specialist go to our website
www.MitsubishiElectric.com.au
They will determine whether a Compact Inverter System or a Power Inverter System best suits your needs, both
in comfort and efficiency. You can either visit one of our Specialist’s Showrooms, or they will happily arrange for
one of their Consultants to come to your home. All Mitsubishi Electric Compact and Power Inverter Systems
are MEPS (Minimum Energy Performance Standards) Compliant, so you can be sure that they will give you the
performance and efficiency that they were designed to deliver.
Mitsubishi Electric Shizuoka Works acquired ISO90001 certification under Series 9000
of the International Standards Organisation (ISO) based on a review of Quality warranties
for the production of air conditioning equipment. The plant also acquired environmental
management system standard ISO 14001 certification.
 NOTICE
* Air conditioners in this brochure contain and operate with refrigerant R410A and synthetic oils.
Before attempting any installation work you must read the installation instructions.
New tools, materials and procedures are required to install these products.
Under Australian Law, only persons suitably licensed are permitted to install and service air conditioning units. The buyer must ensure that the person and/or company who is install,
service or repair the air conditioner has the necessary licences, qualifications and experience to perform the work. Suitable access for warranty and service is required.
Refer to conditions of warranty on the Mitsubishi Electric website. For future improvement, specifications, designs of product and availability are subject to change without notice.
Refer to Country, Commonwealth, State or Territory legislation, regulations and industry codes of practice, before installation of these products. Recovery and disposal of waste material
must comply with Country, Commonwealth, State or Territory guidelines.
* Do not install indoor units in areas (e.g., mobile phone base stations) where the emission of VOCs such as phthalate compounds and formaldehyde is known to be high as this may
result in a chemical reaction.
* When installing or relocating or servicing the air conditioners, use only the specified refrigerant (R410A) to charge the refrigerant lines. Do not mix it with any other refrigerant and do not
allow air to remain in the lines.
If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and may result in an explosion and other hazards. The use of any refrigerant
other than that specified for the system will cause mechanical failure or system malfunction or unit breakdown. In the worst case, this may lead to a serious impediment to securing
product safety.
* Specifications, designs and other content appearing in this brochure are current as at January 2015 and are subject to change without notice. Diagrams are representations for
illustrative purposes only.
33
NOTES
34
NOTES
35
For more information contact
www.mitsubishielectric.com.au
Call 1300 722 228
Distributed and guaranteed throughout Australia by
MITSUBISHI ELECTRIC AUSTRALIA PTY. LTD.
(Incorporated in New South Wales) A.B.N. 58 001 215 792
Specifications, designs and other content appearing in this brochure is current at the time of printing, and is subject to change without notice.
Images are representational for illustration purposes. PRINTED: JULY 2017