Install & Operation Guide
chilled
ambient
sparkling
Cold & Ambient (DC15A)
Cold & Sparkling (DC15AS)
Contents
Page No
Description
5
6
7
8
9
11
12
13
14
15
16
17
18
19
20
21
29
41
Range Overview & Features
Introduction
Controls
Storage Cabinet & Leak Detection Overview
Specification
Installation & Operation
Major Components
Parts to Assemble
Installation Pipework
CO2 Bottle Installation
Operation
Sparkling Operation
Operation Control Panel
Maintenance & Removal
General Safety Advice
Trouble Shooting
Electrical Measurements, Component Diagrams & Lists
Electrical Circuit & Water Pathway Diagrams
GB
DC15 - UNITE - Install & Operation Guide
The manual is intended as a guide only. Printed by Azure UK NR9 5SP UK
2
DC15 - UNITE - Install & Operation Guide
Contents
5.
Range Overview & Features
6.
7.
Introduction
Controls
8.
9.
Storage Cabinet & Leak Detection Overview
Specification
11. Installation & Operation
12.
Major Components
13.
Parts to Assemble
14.
15.
Installation Pipework
CO2 Bottle Installation
16.
17.
18.
19.
Operation
Sparkling Operation
Operation Control Panel
Maintenance & Removal
20.
General Safety Advice
21. Trouble Shooting
22.
24.
25.
26.
Fault
Fault
Fault
Fault
Diagnosis Guide
Diagnosis Guide
Diagnosis Guide
Diagnosis Guide
1
3
4
5
& 2 – No Water Dispenses
– Water Dispenses but not correct Temperature
– Water Leaks
& 6 – Miscellaneous
29. Electrical Measurements, Component Diagrams & Lists
30.
31.
32.
Electrical Test Measurement Values Guide
Exploded Component Diagram DC15A
DC15A – Parts List
36.
37.
Exploded Component Diagram DC15AS
DC15AS – Parts List
41. Electrical Circuit & Water Pathway Diagrams
42.
43.
Electrical Circuit Diagram DC15A
Electrical Circuit Diagram DC15AS
44.
45.
Water Pathway Diagram DC15A
Water Pathway Diagram DC15AS
3
DC15 - UNITE - Install & Operation Guide
4
DC15 - UNITE - Install & Operation Guide
DC15 Unite - All Models
Range Overview & Features
Contents:
6. Introduction
7. Controls
8. Storage Cabinet & Leak Detection Overview
9. Specification
5
DC15 - UNITE - Install & Operation Guide
Range Overview & Features
Introduction
A range of floorstanding water dispensers, available in two different operational types:

DC15 A Cold and Ambient

DC15 AS Cold, Ambient and Sparkling
All Types
All Unite models are self-contained machines with robust steel framed cabinets and attractively injection moulded
plastic front, side and top panels. There is sufficient space internally for filters etc to be fitted behind the door
panel.
An IEC Power Lead is supplied for connection to the IEC socket found on the rear of all models (An additional
Schuko type is supplied for the European market).
DC15 Cold and Ambient Model
The Cold Temperature is thermostatically controlled via the adjustment screw on the back of the machine. This
setting is factory set and is not necessary to adjust in most cases (see Controls).
The Cold Tank can be drained via the lower of the two Drain Ports on the rear of the machine.
A Direct Chill cold water dispenser where water is used as the cooling medium in the Direct Chill tank. This is
automatically filled and controlled by the level control system upon installation. This tank is then chilled via the outer
evaporation coil of the capillary controlled refrigeration compression system.
The level control system also incorporates a leak detection device within the cabinet which switches the machine
off in the event of detecting water.
The Cold Temperature is thermostatically controlled via the adjustment screw on the back of the machine. This is
factory set and is not necessary to adjust in most cases (see Controls).
The Cold Tank can be drained via the upper of the two Drain Parts on the rear of the machine.
DC15 Cold, Ambient and Sparkling Model
Water is chilled as it passes through the coil immediately before dispense. Still, cold and ambient water dispense
is at inlet pressure via the DC current operated solenoid valves. Chilled water is pumped under pressure into the
carbonator which it fitted inside the same coil. The carbonator is also level controlled and allows the sparkling
effect to occur through saturation with CO2.
6
DC15 - UNITE - Install & Operation Guide
Controls
All Models
On/Off switches – at rear of machine.
Cold – switches Cooling Operation on/off
Soda – switches Sparkling Operation on/off
Cold thermostat – inside rear of machine
Factory set to:
NB: Turn clockwise to decrease water temperature.
(The thermostat is set to maximum and should not need adjustment.)
Sparkling Button
Cold Button
Ambient Button
Press to dispense Sparkling Water
Press to dispense Cold Water
Press to dispense Ambient water
Green LED
Yellow LED
10A Fuse
Colours to show Cooling Operation is switched on
Colours to show the Sparkling Operation is switched on
On rear of machine, integral with IEC socket
7
DC15 - UNITE - Install & Operation Guide
Storage Cabinet
All models are fitted with a lower storage area.
The Door Panel is hinged and fastened with Magnetic Catches. There is a removable cover protecting the machine
parts.
Every DC15 Unite is supplied with a Level Sensor Kit, comprising:


Water Container
Sensor Unit (c/w 2 no. CR3032 batteries)
Simply connect the Drainage Tubing that is pre-fitted, into the top of the container and remove the protective sleeve
from the probes.
When the container becomes full:
A bleeping alarm will sound for 1 minute when an attempt is made to dispense a drink. This is an alarm of 3
bleeps repeating every 10-15 seconds. This 1 minute cycle will repeat every time a dispense button is pressed.
The LED lighting at the base of the faucet will flash ON/OFF slowly for 1 minute. This too is repeated every time a
dispense button is pressed
Leak Detection
Notice:
This machine is equipped with a leakage detection device. When leaking is detected, the dispense operation will
be cut off automatically.
This is indicated by the alarm signalling as also described above.
To reset:
1.
2.
3.
4.
Unplug the machine and open the lower door.
Locate the source of leakage and rectify.
Locate and dry the detection probes in the bottom of the machine along with the surrounding area.
Locate the Leak Detector valve under the front edge of the lower shelf and reset the red lever (push it in) on
the reverse side.
5. Reconnect the power to machine and test operation.
8
DC15 - UNITE - Install & Operation Guide
Specifications
COOLING SYSTEM
All
Models
High efficiency compression system with capillary control.
Premium quality long life hermetic compressor. Compact
internal condenser – fan assisted for greater efficiency.
Environmentally friendly R134A refrigerant.
3.5 litre insulated stainless steel chiller tank with level control
containing stainless steel cold water direct chill coil.
Thermostatically controlled chilled water temperature. Stainless
steel carbonator tank with independent level control fitted inside
coil. High capacity, low voltage diaphragm inlet pump.
COLD TEMPERATURE
2°C to 11°C.
THROUGHPUT PER HOUR
18 litres cold < 12°C / 16 litres sparkling <12°C.
DISPENSE
Ergonomically designed and situated light touch sensitive
controls.
MAXIMUM RUNNING
POWER CONSUMPTION
85 watt. (Cooling Operation)
POWER REQUIREMENTS
230 volt/50Hz supply required.
POWER SUPPLY
IEC power socket.
WATER CONNECTION
1/4 inch quick connection.
CO2 CONNECTION
1/4 inch quick connection.
DIMENSIONS
(w x d x h) 520 x 410 x 1010mm (Dispense area)
1300 GC Faucet
WEIGHTS
180 watt. (Intermittent Sparkling Operation)
DC15A
27.0 kg
DC15AS 30.9 kg
9
DC15 - UNITE - Install & Operation Guide
10
DC15 - UNITE - Install & Operation Guide
DC15 Unite - All Models
Installation & Operation
Contents:
12. Major Components
13. Parts to Assemble
14. Installation Pipework
15.
16.
17.
18.
19.
CO2 Bottle Installation
Operation
Sparkling Operation
Operation Control Panel
Maintenance & Removal
20. General Safety Advice
11
DC15 - UNITE - Install & Operation Guide
Major Components
Water Tap Set
Right Table Plate
Screw Cover
Screw
Screw
Handle
Drip Tray
Left Table Plate
Cold Water Tank
12
IC Board Control Panel
DC15 - UNITE - Install & Operation Guide
Parts to Assemble
Right Table Plate
Water Tap Set
Screw Cover
Screw
Screw
Handle
Drip Tray
Left Table Plate
13
DC15 - UNITE - Install & Operation Guide
Installation Pipework
1.
Connect to mains water supply. Fit check valve, water block etc. as required.
2.
Connect the 1/4” pipe to the 1/4” inlet connection on the back of the machine.
Cold Water Drain
Water Inlet Connection (1/4”)
1/4” Water Inlet Pipe
14
DC15 - UNITE - Install & Operation Guide
CO2 Bottle Installation
1.
Fit the CO2 regulator to a CO2 cylinder. (Fitting to a rechargeable cylinder requires an additional adapter fitting).
Connect the assembled cylinder to the dispenser.
Pressure Regulator
CO2 Cylinder
CO2 Pipe
2.
Connect the dispenser to the assembled CO2 cylinder.
CO2 Pipe
15
DC15 - UNITE - Install & Operation Guide
Operation
1.
After the water supply pipe is
connected, open the supply.
Connect the IEC power lead and the
tank(s) will automatically begin to fill
with water. When the tanks are full,
press the cold and ambient dispense
buttons. Flush approx. 10 litres of
water through the machine, mainly
using the cold button.
2.
When completed switch on the cold power switch on the back to start the cooling system. The yellow LED
indicator on the control PCB will show. The initial cooling cycle will take approx. 1 hour.
Press the ambient button to dispense
Cold Power Switch
ambient water.
There is an in-built safety feature
which prevents a dispense valve
remaining open for more than 1
minute. When dispensing this is
indicated by a bleep alarm and the
dispense stops. Simply release the
button to reset and then start again
16
DC15 - UNITE - Install & Operation Guide
Sparkling Operation
1.
Sparkling Mode Switch
Switch on the sparkling/carbonated
water mode
2.
Press the sparkling water button and flush through approx. 10 litres of water. (A
short pause will be needed every 500ml to allow the carbonation tank to refill).
Sparkling Mode Indicator
Sparkling Water Button
3.
Check the regulator gauge is stabilised at the required pressure.
17
DC15 - UNITE - Install & Operation Guide
Operation - Control Panel
When water has been dispensed over 60 seconds, the LED light will flash due to the purpose of protection. Please
release the water button and stop the light from flashing.
Chilling Indicator
Cold Power Indicator
Cold Water Button
Ambient Water Button
Chilling Indicator
Ambient Water Button
Cold Power Indicator
Cold Water Button
Sparkling Water Button
18
DC15 - UNITE - Install & Operation Guide
Maintenance & Removal
1.
Please make sure the machine is
completely disconnected from
electricity before carrying out any
maintenance work.
2.
To drain the Direct Chill tank, remove
the cap on the back of the machine.
We recommend it is refitted
immediately upon draining being
completed.
Cold Water Drain
Caps
19
DC15 - UNITE - Install & Operation Guide
General Safety Advice
Leave a space no less
than 15cm between the
wall and dispenser.
Keep the machine away
from sunlight, heat and
moisture.
Always connect to a
fused electrical supply
outlet, protected by an
RCD.
20
DC15 - UNITE - Install & Operation Guide
DC15 Unite - All Models
Trouble Shooting
Contents:
22.
Fault Diagnosis Guide 1 & 2 – No Water Dispenses
24.
25.
Fault Diagnosis Guide 3 – Water Dispenses but not correct Temperature
Fault Diagnosis Guide 4 – Water Leaks
26.
Fault Diagnosis Guide 5 & 6 – Miscellaneous
21
DC15 - UNITE - Install & Operation Guide
Trouble Shooting
Fault Diagnosis Guide 1 – No Water Dispenses
Problem/ Report
Possible Cause
Suggested Action
Water Supply turned off
Check all Taps/valves/ filters on incoming supply
are fitted and are turned on.
No Electricity/Power Supply
Check power cord connected and live and
No Water Dispenses
From Ambient
Valve
machine is switched on.
“Waterblock” tripped off
Reset “Waterblock” (and check for cause of
leakage)
Check valve action. Carefully dismantle valve and
clean out/part replace/complete replace as
needed.
Faulty Solenoid Valve
Valve clicking but no water-Check if hole in centre
of washer is clear.
Valve not clicking-Check voltage output when
operated. If no output replace PCB.
If there is output, replace solenoid coil/whole valve
coil/whole valve assembly complete.
From Cold Valve
22
Leak detector has disabled
dispense operation.
Check for internal leakage, ensure probes are dry
and reset.
Firstly all as for Ambient Tap
Carry out checks and actions as for ambient tap.
Chiller tank frozen – Faulty
Thaw out, check and replace thermostat or reset
Thermostat/Incorrect Setting
temperature set point.
Chiller tank Frozen-faulty air
Thaw out, check operation and replace Air pump if
pump
necessary.
DC15 - UNITE - Install & Operation Guide
Trouble Shooting
Fault Diagnosis Guide 2 – No Water Dispenses (continued)
Problem/ Report
Possible Cause
Suggested Action
No Water Dispenses (continued)
From Ambient or
Cold Valve
From Sparkling
Valve
Button not being pressed
enough
Press button firmly N.B.
Faulty controls PCB – no
Replace PCB – Check for 24 VDC outputs if
voltage output.
necessary.
Carbonation System switched
off.
Check switch on back of the machine
Firstly as for Ambient and or
Cold Dispense
Carry out the checks and actions as for Ambient
Dispense
Low or no CO2 pressure.
Check and replace cylinder as necessary
Pump not operating
Check carbonator level Control System.
Check probes connected/leads attached. Check
power supply to pump.
Carbonator Tank over
Switch Sparkling System off, shut off CO2 supply
pressurised with CO2
and release CO2 from carbonator. Switch
Sparkling system on, then check pump operation.
If normal, open CO2 supply after pump has
stopped.
Pump Feed Valve not opening
Check valve function:
 If no input DC voltage, check rectifier and
level control module.
 If input but no function, check valve coil.
Replace parts as needed.
23
DC15 - UNITE - Install & Operation Guide
Trouble Shooting
Fault Diagnosis Guide 3 – Water Dispenses but not correct
Temperature
Problem/ Report
Possible Cause
Suggested Action
Water Dispenses but not correct Temperature
Ambient Water too
warm
Low usage and / or fed from
water supply pipe in warm
Advise user replacing external causes and solutions.
ducting.
Cold water not
Cooling and or Sparkling
Check switch positions on the back of the machine
Cold
System switched off.
as necessary.
Compressor runs and switching
off (cool/warm to touch) -
Decrease Cold Thermostat set point.
Thermostat set too high.
24
Faulty Thermostat.
Replace Thermostat
Compressor runs but not
Switching off (Hot to touch).
Contact Aftersales Support.
Refrigeration problem.
Contact Aftersales Support.
Compressor not running at all.
Check voltage path through the machine.
No electricity power supply.
Check power cord connected and live, and
machine is switched on.
Compressor only hums slightly/
briefly.
Check and replace relays.
Relays loose.
Check and refit relays.
Compressor Faulty.
Contact Aftersales Support.
DC Tank Empty
Check water level and replace level control module
in fill valve as needed.
DC15 - UNITE - Install & Operation Guide
Trouble Shooting
Fault Diagnosis Guide 4 – Water Leaks
Problem/ Report
Possible Cause
Suggested Action
Water Leaks
Water lying on top Overflowing Waste Container.
edge of lower door
panel and / or
Empty Waste Container and check drain pipe is
not blocked.
bottom of Cabinet.
Water lying in
Faulty Water System Level
bottom of machine
Sensor.
Check operation and replace batteries if needed.
Leak in supply inlet pipe work
and / or filter.
Locate and repair accordingly.
Leak from machine water pipe
work fittings.
Locate and repair accordingly.
DC tank over overfilling
Check level control module and fill valve function.
Check pressure and fit pressure reducing valve if
needed.
25
DC15 - UNITE - Install & Operation Guide
Trouble Shooting
Fault Diagnosis Guide 5 – Miscellaneous
Problem/ Report
Possible Cause
Suggested Action
Bleeping Noise
Waste Container full/Internal
water leak.
Empty Waste Container. Check and reset Leak
Detector.
No LED function
No electricity to Machine.
Check power supply and reconnect as necessary
Miscellaneous
Lights
(Also check out other symptoms as described
separately).
Machine shakes on
Start-Up
Check Fuse in IEC Socket.
Replace if necessary.
Faulty Control PCB (Machine
working normally otherwise).
Replace Control PCB.
Compressor Starting.
No action needed. This is quite normal.
Level Surface.
Uneven Surface.
Level up machine using adjustable feet.
Missing Fixings.
Replace missing fixings.
Tripping out
Machine in high humidity
Discuss possible repositioning with customer.
Electricity supply
environment.
Electrical circuitry faults.
Test, identify and address accordingly. See
Electrical Diagrams.
(Contact Azure for further advice).
26
DC15 - UNITE - Install & Operation Guide
Trouble Shooting
Fault Diagnosis Guide 6 – Miscellaneous
Problem/ Report
Possible Cause
Suggested Action
Slow but Continuous Water Dispense
From Ambient or
Cold Water Valve
Low incoming Water pressure.
Consider re-plumbing to alternative supply if
possible or boosting the inlet supply pressure.
From Sparkling
Low/no CO2 Pressure.
Check Regulator and/or replace cylinder.
Water Valve
Intermittent Water Dispense
From Ambient or
Cold Water Valve
From Ambient or
Cold Water Valve
and hammering
noise
Trapped air in pipe work
(especially where water
pressure is low or after filter
change).
Hold button on to purge air out. (This could take
several minutes where pressure is low).
Button Not being pressed
enough.
Press button firmly N.B. This could be caused by a
surrounding cold environment making the action
stiffer.
Faulty Control PCB
Replace Control PCB.
Fluctuating mains water
pressure situation.
Contact Azure regarding special replacement
washers available.
Use filter function if available.
Continuous Water Dispense
From Ambient/
Cold or Sparkling
Water Valve.
Button jammed on/faulty.
Replace Control PCB and or/ button Panel as
needed.
Debris blocking hole in
diaphragm washer.
Dismantle Valve and clean out.
Faulty solenoid valve.
Check valve and replace if needed.
27
DC15 - UNITE - Install & Operation Guide
28
DC15 - UNITE - Install & Operation Guide
DC15 Unite - All Models
Electrical Measurements, Component Diagrams &
Lists
Contents:
30.
31.
32.
Electrical Test Measurement Values Guide
Exploded Component Diagram DC15A
DC15A – Parts List
36.
Exploded Component Diagram DC15AS
37.
DC15AS – Parts List
29
DC15 - UNITE - Install & Operation Guide
Electrical Test Measurement Values Guide
DC15A
DC15AS
Primary
12Ω
11Ω
Secondary
34Ω
22Ω
Total
46Ω
33Ω
230V
230V
3–6
0Ω
0Ω
3–5
36Ω
26Ω
5–6
36Ω
26Ω
Compressor Relay Resistance
Klickson
1.7Ω
1.7Ω
Solenoid Coil
Resistance
Cold Dispense
(0906)
84Ω
84Ω
Ambient Dispense
(0906)
84Ω
84Ω
Sparkling Dispense
(0906)
84Ω
84Ω
Tank Fill
(0906)
84Ω
84Ω
Pump Feed
(0906)
84Ω
84Ω
Cold Dispense
(All)
N/A
N/A
Hot Dispense
(All)
84Ω
84Ω
215VDC
215VDC
Compressor
Resistance
Compressor Input Voltage
Compressor Relay
Resistance
PTC
Solenoid Valve Input Voltage
Cooling
Current/Power
Heater Resistance
Normal
At 230V
0.8A/85-95W
0.8A/85-95W
Reduced
At 230V
0.7A/80-85W
0.7A/80-85W
Ineffective
At 230V
<0.7A/80W
<0.7A/80W
Main Element
(400W/1.74A)
N/A
N/A
(535W/2.33A)
N/A
N/A
(825W/3.58A)
63Ω
63Ω
(35W/0.15A)
N/A
N/A
(50W/0.22A)
N/A
N/A
230V
N/A
Standby Element
Heater Band Input Voltage
30
DC15 - UNITE - Install & Operation Guide
Exploded Component Diagram DC15A
31
DC15 - UNITE - Install & Operation Guide
DC15A – Parts List
32
Item
Part Description
QTY
P1
Door Panel (Shell only)
1
P2
Door Panel Infill
1
P3
Rear Cover Panel
1
P4
Top Panel (Upper)
1
P5
Top Panel (Lower)
1
P6
Right Top Panel Cover Plate
1
P7
Left Top Panel Cover Plate
1
P8
Faucet Cover (Upper)
1
P9
Faucet Body
1
P10
Drainage Grill
1
P11
Faucet LED Lens
1
P12
Faucet Base
1
P13
Top Panel Cover Plate Bracket
2
P14
Dispense Manifold Body
1
P15
Dispense Manifold Outlet
1
P16
Dispense Manifold Core
3
P17
Base Panel
1
P18
Cup Dispenser Tube Set - Complete
2
P19
Waste Water Container
1
P20
Compressor Mount Sleeve
4
P21
Drain Outlet Fitting
1
P22
Faucet Fixing Cover
2
P23
O-Ring
3
P24
2-Port Drainage Outlet
1
P25
1/4" Spigot Branch Tee
1
P26
1/4" Straight Bulkhead Fitting
1
P27
M16 Hexagon Nut
1
P28
1/4" Spigot Elbow Fitting
1
P29
1/4" Stem Elbow
4
P30
1/4" Spigot Tee
1
P31
Grit Filter
1
P32
Drainage Pipe
1
Recommended
Engineer Spares
Notes
DC15 - UNITE - Install & Operation Guide
DC15A – Parts List (continued)
Item
Part Description
QTY
P33
1/4" Faucet Pipe
2
P34
Single Check Valve
1
P35
3/8"/1/4" Unequal Tee
1
P36
3/8" Water Pipe
1
P37
1/4" Water Pipe
6
P38
1/4" Water Pipe
1
P39
1/4" Water Pipe
1
P40
1/4" Water Pipe
1
P41
Internal Cover Guard
M1
Mid Shelf
2
M2
Left Side Panel
1
M3
Right Side Panel
1
M4
Faucet Internal Bracket
1
M5
Switch Mounting Bracket
1
M6
Solenoid Mounting Bracket
1
M7
Fixing Screw
6
M8
Fixing Screw
31
M9
Condenser
1
M10
Refrigeration Drier
1
M11
Capillary Tube
1
M12
Charging Tube
1
M13
Magnetic Catch
4
M14
Fixing Screw
2
M15
Fixing Screw
4
M16
T Type Nut
2
M17
Fixing Screw
6
M18
Fixing Screw
12
M19
Fixing Screw
12
M20
Door Panel Hinge Pin
1
M21
Fixing Screw
2
M23
Fixing Screw
2
M23
Fixing Screw
1
Recommended
Engineer Spares
Notes
33
DC15 - UNITE - Install & Operation Guide
DC15A – Parts List (continued)
34
Item
Part Description
QTY
Recommended
Engineer Spares
M24
Drain Container Mounting Plate
1
M25
Fixing Screw
2
M26
Fan Mounting Bracket
1
M27
Thermostat Mounting Bracket
1
M28
St/St Dispense Screen
3
M29
Fixing Screw
1
M30
Fixing Screw
2
M31
Fixing Screw
2
M32
Filter Bracket
1
M33
Fixing Screw
13
M34
Leak Detector Probe
2
M35
Fixing Screw
2
E1
Main Control PCB
1

E2
Level Control Module
1

E3
Faucet Feature LED Block
1
E4
Compressor
1
E5
On/Off Switch
1
E6
Fan
1
E7
IEC Inlet - Fused
1
E8
IEC Power Cord set
1
E9
Level Sensor Module
1
E10
Transformer (24vDC)
1
E11
Power Extension Cord
1
E12
Solenoid Valve
3

E13
Cold Thermostat
1

E14
Main Wiring Harness
1
E15
Level Control Wiring Harness
1
E16
Fan Wiring Harness
1
E17
Level Control Wiring Harness
1
E18
24V Power Connecting Cable
1
E19
Level Sensor Module Harness
1
E20
Earth Wire Harness
1


Notes
DC15 - UNITE - Install & Operation Guide
DC15A – Parts List (continued)
Item
Part Description
QTY
Recommended
Notes
Engineer Spares
E21
Leak Detector Module
1
E22
Leak Detection Probe
1
C1
Cold Tank - Set
1
C2
Cold Tank - Lid
1
C3
Cold Tank Lid Fastening Ring
1
C4
Cold Tank Outlet Seal
1
C5
Cold Tank Outlet Fitting
1
C6
Outlet Back Nut
2
C7
Fitting Back Nut
1
C8
DC Coil Bracket
1
C9
DC Coil
1
C10
1/4" Angled Bulkhead Connector
1
C11
1/4" Clip
2
C12
Thermostat Sleeve
1
C13
1/4" Internal DC Connection Tube
1
C14
DC Circulation Pump Set
1
C15
Elbow Fitting
1
C16
Bung
1
C17
1/4" Straight Bulkhead Connector
1
C18
Insulation Filler
2
C19
1/4" Stem Elbow
2
C20
Top Insulated Cover
1
C21
Cold Tank Insulation Sleeve
1
C22
Angled Silicon Tube
1
C23
Pipe Sleeve
1
C24
Silicon Pipe
1
C25
Thermal Insulation
1
C26
Level Control Probe
3
C27
1/4" Elbow
1
C28
O-Ring
1
O1
Control Panel Label
1
O2
D/Sided Fastener
1
O3
Pipe Insulation
1
O4
D/Sided Fastener
1

35
DC15 - UNITE - Install & Operation Guide
Exploded Component Diagram DC15AS
36
DC15 - UNITE - Install & Operation Guide
DC15AS – Parts List
Item
Part Description
QTY
P1
Door Panel (Shell only)
1
P2
Door Panel Infill
1
P3
Rear Cover Panel
1
P4
Top Panel (Upper)
1
P5
Top Panel (Lower)
1
P6
Right Top Panel Cover Plate
1
P7
Left Top Panel Cover Plate
1
P8
Faucet Cover (Upper)
1
P9
Faucet Body
1
P10
Drainage Grill
1
P11
Faucet LED Lens
1
P12
Faucet Base
1
P13
Top Panel Cover Plate Bracket
2
P14
Dispense Manifold Body
1
P15
Dispense Manifold Outlet
1
P16
Dispense Manifold Core
3
P17
Base Panel
1
P18
Cup Dispenser Tube Set - Complete
2
P19
Waste Water Container
1
P20
Compressor Mount Sleeve
4
P21
Drain Outlet Fitting
1
P22
Faucet Fixing Cover
2
P23
O-Ring
3
P24
2-Port Drainage Outlet
1
P25
1/4" Spigot Branch Tee
2
P26
1/4" Straight Bulkhead Fitting
2
P27
M16 Hexagon Nut
2
P28
1/4" Spigot Elbow Fitting
2
P29
1/4" Stem Elbow
9
P30
1/4" Tee Fitting
1
P31
Grit Filter
1
P32
Drainage Pipe
1
P33
1/4" Faucet Pipe
1
P34
Single Check Valve
1
P35
3/8"/1/4" Unequal Tee
1
P36
3/8" Water Pipe
1
P37
1/4" Water Pipe
12
P38
1/4" Water Pipe
3
P39
1/4" Water Pipe
8
Recommended
Engineer Spares
Notes
37
DC15 - UNITE - Install & Operation Guide
DC15AS – Parts List (continued)
38
Item
Part Description
QTY
P40
1/4" Water Pipe
1
P41
1/4" Water Pipe
1
P42
Internal Cover Guard
1
P43
PVC Sleeving
1
M1
Mid Shelf
2
M2
Left Side Panel
1
M3
Right Side Panel
1
M4
Faucet Internal Bracket
1
M5
Switch Mounting Bracket
1
M6
Solenoid Mounting Bracket
1
M7
Fixing Screw
6
M8
Fixing Screw
39
M9
Condenser
1
M10 Refrigeration Drier
1
M11 Capillary Tube
1
M12 Charging Tube
1
M13 Magnetic Catch
4
M14 Fixing Screw
2
M15 Fixing Screw
4
M16 Pipe Spring Clip
11
M17 Fixing Screw
6
M18 Fixing Screw
13
M19 Fixing Screw
8
M20 Door Panel Hinge Pin
1
M21 Fixing Screw
2
M23 Fixing Screw
2
M23 Fixing Screw
1
M24 Drain Container Mounting Plate
1
M25 Fixing Screw
2
M26 Fan Mounting Bracket
1
M27 Thermostat Mounting Bracket
1
M28 St/St Dispense Screen
3
M29 Fixing Screw
1
M30 Fixing Screw
2
M31 Fixing Screw
2
M32 Filter Bracket
1
M33 Fixing Screw
13
M34 Level Sensor Probe
2
M35 Fixing Screw
2
Recommended
Engineer Spares
Notes
DC15 - UNITE - Install & Operation Guide
DC15AS – Parts List (continued)
Item
Part Description
QTY
E1
Main Control PCB
1
Recommended
Engineer Spares

E2
Level Control Module
1

E3
Faucet Feature LED Block
1
E4
Compressor
1
E5
On/Off Switch
2
E6
Fan
1
E7
IEC Inlet - Fused
1
E8
IEC Power Cordset
1
E9
Level Sensor Module
1
E10
Power Extension Cord
1
E11
Level Sensor Module Harness
1
E12
Solenoid Valve
5

E13
Cold Thermostat
1

E14
Main Wiring Harness
1
E15
Level Control Wiring Harness
1
E16
Fan Wiring Harness
1
E17
Level Control Wiring Harness
1
E18
24V Power Connecting Wire
1
E19
Leak Detection Probe
1
E20
Earth Wire Harness
1
E21
Leak Detector Module
1
C1
Cold Tank - Set
1
C2
Cold Tank - Lid
1
C3
Cold Tank Lid Fastening Ring
1
C4
Cold Tank Outlet Seal
1
C5
Cold Tank Outlet Fitting
1
C6
Outlet Back Nut
2
C7
Fitting Back Nut
2
C8
1/4" Angled Bulkhead Connector
2
C9
DC Coil
1
C10
1/4" Straight Bulkhead Fitting
1
C11
1/4" Clip
2
C12
Thermostat Sleeve
1
C13
1/4" Internal DC Connection Tube
1
C14
DC Circulation Pump Set
1
C15
Elbow Fitting
1
C16
Fixing Screw
4
C17
DC Circulation Pump Pipe Clip
1
C18
Fixing Screw
8
Notes

39
DC15 - UNITE - Install & Operation Guide
DC15AS – Parts List (continued)
40
Item
Part Description
QTY
C19
1/4" Stem Elbow
5
C20
Top Insulated Cover
1
C21
Cold Tank Insulation Sleeve
1
C22
Angled Silicon Tube
1
C23
Pipe Sleeve
1
C24
Silicon Pipe
1
C25
Thermal Insulation
1
C26
Level Control Probe
3
C27
Bung
1
C28
O-Ring
1
C29
Carbonation Tank
1
C30
Single Check Valve
2
C31
1/4" Water Pipe
3
C32
PVC Tubing
2
C33
Elbow Fitting
2
C34
Carbonation Pump
1
C35
Transformer (24vDC)
1
O1
Control Panel Label
1
O2
D/Sided Fastener
1
O3
Pipe Insulation
1
Recommended
Engineer Spares

Notes
DC15 - UNITE - Install & Operation Guide
DC15 Unite - All Models
Electrical Circuit & Water Pathway Diagrams
Contents:
42. Electrical Circuit Diagram DC15A
43. Electrical Circuit Diagram DC15AS
44. Water Pathway Diagram DC15A
45. Water Pathway Diagram DC15AS
41
DC15 - UNITE - Install & Operation Guide
Electrical Circuit Diagram DC15A
Red
Blue
Yellow
Orange
Purple
White
Compressor
Thermostat
Detection
Probe
Leak
Detector
Module
Cold Water
Tank
Power
Switch
Signal Harness
(Red/Blue/white/yellow)
Level
Sensor
PCB
6 LED Faucet
Illumination
24V DC
Transformer
Cold Water Tank
Solenoid Valve
Ambient Dispense Solenoid
Cold Dispense
Solenoid
Fan
Main Control PCB
Ambient Button
42
Cold Button
DC
OUT
DC15 - UNITE - Install & Operation Guide
Electrical Circuit Diagram DC15AS
Red
Blue
Yellow
Orange
Purple
White
Carbonated
Water Tank
Compressor
Thermostat
Detection
Probe
Leak
Detector
Module
Cold Water
Tank
Power
Switches
Signal Harness
(Red/Blue/white/yellow)
Soda
Pump
Level
Sensor
PCB
24V DC
Transformer
Soda Water Tank
Solenoid Valve
Cold Water Tank
Solenoid Valve
6 LED Faucet
Illumination
DC
OUT
Ambient Dispense Solenoid
Soda Dispense Solenoid
Cold Dispense Solenoid
Controlled
Module for
leak
detection
Fan
Leak Detector
Level Sensor
Ambient Button
Main Control PCB
Soda Button
Cold Button
43
DC15 - UNITE - Install & Operation Guide
Water Pathway Diagram DC15A
Water
Inlet
Leak
Detector
Direct Chill Tank
Direct Chill Tank Fill Solenoid
Ambient Dispense Solenoid
Faucet
Drainage
Outlet
Direct Chill Coil
Cold Dispense Solenoid
44
DC15 - UNITE - Install & Operation Guide
Water Pathway Diagram DC15AS
Water
Inlet
Leak
Detector
Soda Water Tank Solenoid Valve
Direct Chill Tank
Direct Chill Tank Fill Solenoid
Ambient Dispense Solenoid
Soda
Pump
Drainage
Outlet
Direct Chill Coil
Cold Dispense Solenoid
Faucet
Sparkling Dispense Solenoid
45
DC15 - UNITE - Install & Operation Guide
aftersales@azureuk.co.uk
+44 (0)1362 656 926
www.borgandoverstrom.com
Ref: Unite.I&O.GB.25.07.13
46
Download PDF